Sample records for total voltage drop

  1. Reduction technique of drop voltage and power losses to improve power quality using ETAP Power Station simulation model

    NASA Astrophysics Data System (ADS)

    Satrio, Reza Indra; Subiyanto

    2018-03-01

    The effect of electric loads growth emerged direct impact in power systems distribution. Drop voltage and power losses one of the important things in power systems distribution. This paper presents modelling approach used to restructrure electrical network configuration, reduce drop voltage, reduce power losses and add new distribution transformer to enhance reliability of power systems distribution. Restructrure electrical network was aimed to analyse and investigate electric loads of a distribution transformer. Measurement of real voltage and real current were finished two times for each consumer, that were morning period and night period or when peak load. Design and simulation were conduct by using ETAP Power Station Software. Based on result of simulation and real measurement precentage of drop voltage and total power losses were mismatch with SPLN (Standard PLN) 72:1987. After added a new distribution transformer and restructrured electricity network configuration, the result of simulation could reduce drop voltage from 1.3 % - 31.3 % to 8.1 % - 9.6 % and power losses from 646.7 watt to 233.29 watt. Result showed, restructrure electricity network configuration and added new distribution transformer can be applied as an effective method to reduce drop voltage and reduce power losses.

  2. Improved Control of Charging Voltage for Li-Ion Battery

    NASA Technical Reports Server (NTRS)

    Timmerman, Paul; Bugga, Ratnakumar

    2006-01-01

    The protocol for charging a lithium-ion battery would be modified, according to a proposal, to compensate for the internal voltage drop (charging current internal resistance of the battery). The essence of the modification is to provide for measurement of the internal voltage drop and to increase the terminal-voltage setting by the amount of the internal voltage drop. Ordinarily, a lithium-ion battery is charged at constant current until its terminal voltage attains a set value equal to the nominal full-charge potential. The set value is chosen carefully so as not to exceed the lithium-plating potential, because plated lithium in metallic form constitutes a hazard. When the battery is charged at low temperature, the internal voltage drop is considerable because the electrical conductivity of the battery electrolyte is low at low temperature. Charging the battery at high current at any temperature also gives rise to a high internal voltage drop. In some cases, the internal voltage drop can be as high as 1 volt per cell. Because the voltage available for charging is less than the terminal voltage by the amount of the internal voltage drop, the battery is not fully charged (see figure), even when the terminal voltage reaches the set value. In the modified protocol, the charging current would be periodically interrupted so that the zero-current battery-terminal voltage indicative of the state of charge could be measured. The terminal voltage would also be measured at full charging current. The difference between the full-current and zero-current voltages would equal the internal voltage drop. The set value of terminal voltage would then be increased beyond the nominal full-charge potential by the amount of the internal voltage drop. This adjustment would be performed repeatedly, in real time, so that the voltage setting would track variations in the internal voltage drop to afford full charge without risk of lithium plating. If the charging current and voltage settings were controlled by a computer, then this method of charge control could readily be implemented in software.

  3. Synchronous Half-Wave Rectifier

    NASA Technical Reports Server (NTRS)

    Rippel, Wally E.

    1989-01-01

    Synchronous rectifying circuit behaves like diode having unusually low voltage drop during forward-voltage half cycles. Circuit particularly useful in power supplies with potentials of 5 Vdc or less, where normal forward-voltage drops in ordinary diodes unacceptably large. Fabricated as monolithic assembly or as hybrid. Synchronous half-wave rectifier includes active circuits to attain low forward voltage drop and high rectification efficiency.

  4. Comment on 'Power loss in open cavity diodes and a modified Child-Langmuir law' [Phys. Plasmas 12, 093102 (2005)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swanekamp, S. B.; Ottinger, P. F.

    In this Comment, it is shown that no modification of the Child-Langmuir law [Phys. Rev.32, 492 (1911); Phys. Rev. 2, 450 (1913)] is necessary to treat the space-charge-limited flow from a diode with an open boundary as reported in Phys. Plasmas 12, 093102 (2005). The open boundary condition in their simulations can be represented by a voltage source and a resistor whose value is the vacuum-wave impedance of the opening. The diode can be represented as a variable resistor whose value depends on the voltage drop across the diode (as measured by the line integral of E across the diodemore » gap). This is a simple voltage-divider circuit whose analysis shows that the real diode voltage drops as the vacuum-wave impedance increases. Furthermore, it is shown that in equilibrium, the voltage drop between the anode and cathode is independent of the path chosen for the line integral of the electric field so that E=-{nabla}{phi} is valid. In this case, the equations of electrostatics are applicable. This clearly demonstrates that the electric field is electrostatic and static fields DO NOT RADIATE. It is shown that the diode voltage drops as the vacuum wave impedance increases and the current drops according to the Child-Langmuir law. Therefore, the observed drop in circuit current can be explained by a real drop in voltage across the diode and not an effective drop as claimed by the authors.« less

  5. Study of imbalanced internal resistance on drop voltage of LiFePO4 battery system connected in parallel

    NASA Astrophysics Data System (ADS)

    Adie Perdana, Fengky; Supriyanto, Agus; Purwanto, Agus; Jamaluddin, Anif

    2017-01-01

    The purpose of this research focuses on the effect of imbalanced internal resistance for the drop voltage of LiFePO4 18650 battery system connected in parallel. The battery pack has been assembled consist of two cell battery LiFePO4 18650 that has difference combination of internal resistance. Battery pack was tested with 1/C constant current charging, 3,65V per group sel, 3,65V constant voltage charging, 5 minutes of rest time between charge and discharge process, 1/2C Constant current discharge until 2,2V, 26 cycle of measurement test, and 4320 minutes rest time after the last charge cycle. We can conclude that the difference combination of internal resistance on the battery pack seriously influence the drop voltage of a battery. Theoretical and experimental result show that the imbalance of internal resistance during cycling are mainly responsible for the drop voltage of LiFePO4 parallel batteries. It is thus a good way to avoid drop voltage fade of parallel battery system by suppressing variations of internal resistance.

  6. On-line and real-time diagnosis method for proton membrane fuel cell (PEMFC) stack by the superposition principle

    NASA Astrophysics Data System (ADS)

    Lee, Young-Hyun; Kim, Jonghyeon; Yoo, Seungyeol

    2016-09-01

    The critical cell voltage drop in a stack can be followed by stack defect. A method of detecting defective cell is the cell voltage monitoring. The other methods are based on the nonlinear frequency response. In this paper, the superposition principle for the diagnosis of PEMFC stack is introduced. If critical cell voltage drops exist, the stack behaves as a nonlinear system. This nonlinearity can explicitly appear in the ohmic overpotential region of a voltage-current curve. To detect the critical cell voltage drop, a stack is excited by two input direct test-currents which have smaller amplitude than an operating stack current and have an equal distance value from the operating current. If the difference between one voltage excited by a test current and the voltage excited by a load current is not equal to the difference between the other voltage response and the voltage excited by the load current, the stack system acts as a nonlinear system. This means that there is a critical cell voltage drop. The deviation from the value zero of the difference reflects the grade of the system nonlinearity. A simulation model for the stack diagnosis is developed based on the SPP, and experimentally validated.

  7. The investigation of an electric arc in the long cylindrical channel of the powerful high-voltage AC plasma torch

    NASA Astrophysics Data System (ADS)

    Rutberg, Ph G.; Popov, S. D.; Surov, A. V.; Serba, E. O.; Nakonechny, Gh V.; Spodobin, V. A.; Pavlov, A. V.; Surov, A. V.

    2012-12-01

    The comparison of conductivity obtained in experiments with calculated values is made in this paper. Powerful stationary plasma torches with prolonged period of continuous work are popular for modern plasmachemical applications. The maximum electrode lifetime with the minimum erosion can be reached while working on rather low currents. Meanwhile it is required to provide voltage arc drop for the high power achievement. Electric field strength in the arc column of the high-voltage plasma torch, using air as a plasma-forming gas, does not exceed 15 V/cm. It is possible to obtain the high voltage drop in the long arc stabilized in the channel by the intensive gas flow under given conditions. Models of high voltage plasma torches with rod electrodes with power up to 50 kW have been developed and investigated. The plasma torch arcs are burning in cylindrical channels. Present investigations are directed at studying the possibility of developing long arc plasma torches with higher power. The advantage of AC power supplies usage is the possibility of the loss minimization due to the reactive power compensation. The theoretical maximum of voltage arc drop for power supplies with inductive current limitations is about 50 % of the no-load voltage for a single-phase circuit and about 30 % for the three-phase circuit. Burning of intensively blown arcs in the long cylindrical channel using the AC power supply with 10 kV no-load voltage is experimentally investigated in the work. Voltage drops close to the maximum possible had been reached in the examined arcs in single-phase and three-phase modes. Operating parameters for single-phase mode were: current -30 A, voltage drop -5 kV, air flow rate 35 g/s; for three-phase mode: current (40-85) A, voltage drop (2.5-3.2) kV, air flow rate (60-100) g/s. Arc length in the installations exceeded 2 m.

  8. Measured radial dependence of the peak sheath voltages present in very high frequency capacitive discharges

    DOE PAGES

    Barnat, E. V.; Miller, P. A.; Hebner, G. A.; ...

    2007-05-16

    In this paper, the radial distribution of the measured voltage drop across a sheath formed between a 300mm electrode and an argon plasma discharge is shown to depend on the excitation radio frequency, under constant power and pressure conditions. At a lower frequency of 13.56MHz, the voltage drop across the sheath is uniform across the 300mm electrode, while at higher frequencies of 60 and 162MHz the voltage drop becomes radially nonuniform. Finally, the magnitude and spatial extent of the nonuniformity become greater with increasing frequency.

  9. Indirect current control with separate IZ drop compensation for voltage source converters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanetkar, V.R.; Dawande, M.S.; Dubey, G.K.

    1995-12-31

    Indirect Current Control (ICC) of boost type Voltage Source Converters (VSCs) using separate compensation of line IZ voltage drop is presented. A separate bi-directional VSC is used to produce the compensation voltage. This simplifies the ICC regulator scheme as the power flow is controlled through single modulation index. Experimental verification is provided for bi-directional control of the power flow.

  10. Electric generation and ratcheted transport of contact-charged drops

    NASA Astrophysics Data System (ADS)

    Cartier, Charles A.; Graybill, Jason R.; Bishop, Kyle J. M.

    2017-10-01

    We describe a simple microfluidic system that enables the steady generation and efficient transport of aqueous drops using only a constant voltage input. Drop generation is achieved through an electrohydrodynamic dripping mechanism by which conductive drops grow and detach from a grounded nozzle in response to an electric field. The now-charged drops are transported down a ratcheted channel by contact charge electrophoresis powered by the same voltage input used for drop generation. We investigate how the drop size, generation frequency, and transport velocity depend on system parameters such as the liquid viscosity, interfacial tension, applied voltage, and channel dimensions. The observed trends are well explained by a series of scaling analyses that provide insight into the dominant physical mechanisms underlying drop generation and ratcheted transport. We identify the conditions necessary for achieving reliable operation and discuss the various modes of failure that can arise when these conditions are violated. Our results demonstrate that simple electric inputs can power increasingly complex droplet operations with potential opportunities for inexpensive and portable microfluidic systems.

  11. Electric generation and ratcheted transport of contact-charged drops.

    PubMed

    Cartier, Charles A; Graybill, Jason R; Bishop, Kyle J M

    2017-10-01

    We describe a simple microfluidic system that enables the steady generation and efficient transport of aqueous drops using only a constant voltage input. Drop generation is achieved through an electrohydrodynamic dripping mechanism by which conductive drops grow and detach from a grounded nozzle in response to an electric field. The now-charged drops are transported down a ratcheted channel by contact charge electrophoresis powered by the same voltage input used for drop generation. We investigate how the drop size, generation frequency, and transport velocity depend on system parameters such as the liquid viscosity, interfacial tension, applied voltage, and channel dimensions. The observed trends are well explained by a series of scaling analyses that provide insight into the dominant physical mechanisms underlying drop generation and ratcheted transport. We identify the conditions necessary for achieving reliable operation and discuss the various modes of failure that can arise when these conditions are violated. Our results demonstrate that simple electric inputs can power increasingly complex droplet operations with potential opportunities for inexpensive and portable microfluidic systems.

  12. A read-in IC for infrared scene projectors with voltage drop compensation for improved uniformity of emitter current

    NASA Astrophysics Data System (ADS)

    Cho, Min Ji; Shin, Uisub; Lee, Hee Chul

    2017-05-01

    This paper proposes a read-in integrated circuit (RIIC) for infrared scene projectors, which compensates for the voltage drops in ground lines in order to improve the uniformity of the emitter current. A current output digital-to-analog converter is utilized to convert digital scene data into scene data currents. The unit cells in the array receive the scene data current and convert it into data voltage, which simultaneously self-adjusts to account for the voltage drop in the ground line in order to generate the desired emitter current independently of variations in the ground voltage. A 32 × 32 RIIC unit cell array was designed and fabricated using a 0.18-μm CMOS process. The experimental results demonstrate that the proposed RIIC can output a maximum emitter current of 150 μA and compensate for a voltage drop in the ground line of up to 500 mV under a 3.3-V supply. The uniformity of the emitter current is significantly improved compared to that of a conventional RIIC.

  13. Total number of longwall faces drops below 50

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fiscor, S.

    2009-02-15

    For the first time since Coal Age began its annual Longwall Census the number of faces has dropped below 50. A total of five mines operate two longwall faces. CONSOL Energy remains the leader with 12 faces. Arch Coal operates five longwall mines; Robert E. Murray owns five longwall mines. West Virginia has 13 longwalls, followed by Pennsylvania (8), Utah (6) and Alabama (6). A detailed table gives for each longwall installation, the ownership, seam height, cutting height, panel width and length, overburden, number of gate entries, depth of cut, model of equipment used (shearer, haulage system, roof support, facemore » conveyor, stage loader, crusher, electrical controls and voltage to face). 2 tabs., 1 photo.« less

  14. Transdermal transport pathway creation: Electroporation pulse order.

    PubMed

    Becker, Sid; Zorec, Barbara; Miklavčič, Damijan; Pavšelj, Nataša

    2014-11-01

    In this study we consider the physics underlying electroporation which is administered to skin in order to radically increase transdermal drug delivery. The method involves the application of intense electric fields to alter the structure of the impermeable outer layer, the stratum corneum. A generally held view in the field of skin electroporation is that the skin's drop in resistance (to transport) is proportional to the total power of the pulses (which may be inferred by the number of pulses administered). Contrary to this belief, experiments conducted in this study show that the application of high voltage pulses prior to the application of low voltage pulses result in lower transport than when low voltage pulses alone are applied (when less total pulse power is administered). In order to reconcile these unexpected experimental results, a computational model is used to conduct an analysis which shows that the high density distribution of very small aqueous pathways through the stratum corneum associated with high voltage pulses is detrimental to the evolution of larger pathways that are associated with low voltage pulses. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Dynamic response characteristics analysis of the doubly-fed wind power system under grid voltage drop

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Wang, J.; Wang, H. H.; Yang, L.; Chen, W.; Xu, Y. T.

    2016-08-01

    Double-fed induction generator (DFIG) is sensitive to the disturbances of grid, so the security and stability of the grid and the DFIG itself are under threat with the rapid increase of DFIG. Therefore, it is important to study dynamic response of the DFIG when voltage drop failure is happened in power system. In this paper, firstly, mathematical models and the control strategy about mechanical and electrical response processes is respectively introduced. Then through the analysis of response process, it is concluded that the dynamic response characteristics are related to voltage drop level, operating status of DFIG and control strategy adapted to rotor side. Last, the correctness of conclusion is validated by the simulation about mechanical and electrical response processes in different voltage levels drop and different DFIG output levels under DIgSILENT/PowerFactory software platform.

  16. Simulating the Gradually Deteriorating Performance of an RTG

    NASA Technical Reports Server (NTRS)

    Wood, Eric G.; Ewell, Richard C.; Patel, Jagdish; Hanks, David R.; Lozano, Juan A.; Snyder, G. Jeffrey; Noon, Larry

    2008-01-01

    Degra (now in version 3) is a computer program that simulates the performance of a radioisotope thermoelectric generator (RTG) over its lifetime. Degra is provided with a graphical user interface that is used to edit input parameters that describe the initial state of the RTG and the time-varying loads and environment to which it will be exposed. Performance is computed by modeling the flows of heat from the radioactive source and through the thermocouples, also allowing for losses, to determine the temperature drop across the thermocouples. This temperature drop is used to determine the open-circuit voltage, electrical resistance, and thermal conductance of the thermocouples. Output power can then be computed by relating the open-circuit voltage and the electrical resistance of the thermocouples to a specified time-varying load voltage. Degra accounts for the gradual deterioration of performance attributable primarily to decay of the radioactive source and secondarily to gradual deterioration of the thermoelectric material. To provide guidance to an RTG designer, given a minimum of input, Degra computes the dimensions, masses, and thermal conductances of important internal structures as well as the overall external dimensions and total mass.

  17. Testing the Auroral Current-Voltage Relation in Multiple Arcs

    NASA Astrophysics Data System (ADS)

    Cameron, T. G.; Knudsen, D. J.; Cully, C. M.

    2013-12-01

    The well-known current-voltage relation within auroral inverted-V regions [Knight, Planet. Space Sci., 21, 741, 1973] predicts current carried by an auroral flux tube given the total potential drop between a plasma-sheet source region and the ionosphere. Numerous previous studies have tested this relation using spacecraft that traverse auroral arcs at low (ionospheric) or mid altitudes. Typically, the potential drop is estimated at the peak of the inverted-V, and field-aligned current is estimated from magnetometer data; statistical information is then gathered over many arc crossings that occur over a wide range of source conditions. In this study we use electron data from the FAST satellite to examine the current-voltage relation in multiple arc sets, in which the key source parameters (plasma sheet density and temperature) are presumed to be identical. We argue that this approach provides a more sensitive test of the Knight relation, and we seek to explain remaining variability with factors other than source variability. This study is supported by a grant from the Natural Sciences and Engineering Research Council of Canada.

  18. Electrowetting-driven spreading and jumping of drops in oil

    NASA Astrophysics Data System (ADS)

    Hong, Jiwoo; Lee, Sang Joon

    2013-11-01

    Electrowetting-based practical applications include digital microfluidics, liquid lenses, and reflective displays. Most of them are performed in water/oil system, because oil medium reduces the contact-angle hysteresis and prevents drop evaporation. In this study, the effects of drop volume, oil viscosity, and applied voltage on the dynamic behaviors of spreading drops, such as transition of spreading pattern and response time, are investigated. Interestingly, jumping phenomena of drops are observed in oil when the applied voltage is turned off after reaching the electrowetted equilibrium radius of drops. A numerical model to predict the transient behavior of jumping drops is formulated based on the phase-field method. The numerical results for the transient deformation of jumping drops show quantitative agreement with the experimental results.

  19. IR-drop analysis for validating power grids and standard cell architectures in sub-10nm node designs

    NASA Astrophysics Data System (ADS)

    Ban, Yongchan; Wang, Chenchen; Zeng, Jia; Kye, Jongwook

    2017-03-01

    Since chip performance and power are highly dependent on the operating voltage, the robust power distribution network (PDN) is of utmost importance in designs to provide with the reliable voltage without voltage (IR)-drop. However, rapid increase of parasitic resistance and capacitance (RC) in interconnects makes IR-drop much worse with technology scaling. This paper shows various IR-drop analyses in sub 10nm designs. The major objectives are to validate standard cell architectures, where different sizes of power/ground and metal tracks are validated, and to validate PDN architecture, where types of power hook-up approaches are evaluated with IR-drop calculation. To estimate IR-drops in 10nm and below technologies, we first prepare physically routed designs given standard cell libraries, where we use open RISC RTL, synthesize the CPU, and apply placement & routing with process-design kits (PDK). Then, static and dynamic IR-drop flows are set up with commercial tools. Using the IR-drop flow, we compare standard cell architectures, and analysis impacts on performance, power, and area (PPA) with the previous technology-node designs. With this IR-drop flow, we can optimize the best PDN structure against IR-drops as well as types of standard cell library.

  20. Compensation of voltage drops in solid-state switches used with thermoelectric generators

    NASA Technical Reports Server (NTRS)

    Shimada, K.

    1972-01-01

    Seebeck effect solid state switch was developed eliminating thermoelectric generator switch voltage drops. Semiconductor switches were fabricated from materials with large Seebeck coefficients, arranged such that Seebeck potential is generated with such polarity that current flow is aided.

  1. High-voltage 4H-SiC trench MOS barrier Schottky rectifier with low forward voltage drop using enhanced sidewall layer

    NASA Astrophysics Data System (ADS)

    Cho, Doohyung; Sim, Seulgi; Park, Kunsik; Won, Jongil; Kim, Sanggi; Kim, Kwangsoo

    2015-12-01

    In this paper, a 4H-SiC trench MOS barrier Schottky (TMBS) rectifier with an enhanced sidewall layer (ESL) is proposed. The proposed structure has a high doping concentration at the trench sidewall. This high doping concentration improves both the reverse blocking and forward characteristics of the structure. The ESL-TMBS rectifier has a 7.4% lower forward voltage drop and a 24% higher breakdown voltage. However, this structure has a reverse leakage current that is approximately three times higher than that of a conventional TMBS rectifier owing to the reduction in energy barrier height. This problem is solved when ESL is used partially, since its use provides a reverse leakage current that is comparable to that of a conventional TMBS rectifier. Thus, the forward voltage drop and breakdown voltage improve without any loss in static and dynamic characteristics in the ESL-TMBS rectifier compared with the performance of a conventional TMBS rectifier.

  2. Drop short control of electrode gap

    DOEpatents

    Fisher, Robert W.; Maroone, James P.; Tipping, Donald W.; Zanner, Frank J.

    1986-01-01

    During vacuum consumable arc remelting the electrode gap between a consumable electrode and a pool of molten metal is difficult to control. The present invention monitors drop shorts by detecting a decrease in the voltage between the consumable electrode and molten pool. The drop shorts and their associated voltage reductions occur as repetitive pulses which are closely correlated to the electrode gap. Thus, the method and apparatus of the present invention controls electrode gap based upon drop shorts detected from the monitored anode-cathode voltage. The number of drop shorts are accumulated, and each time the number of drop shorts reach a predetermined number, the average period between drop shorts is calculated from this predetermined number and the time in which this number is accumulated. This average drop short period is used in a drop short period electrode gap model which determines the actual electrode gap from the drop short. The actual electrode gap is then compared with a desired electrode gap which is selected to produce optimum operating conditions and the velocity of the consumable error is varied based upon the gap error. The consumable electrode is driven according to any prior art system at this velocity. In the preferred embodiment, a microprocessor system is utilized to perform the necessary calculations and further to monitor the duration of each drop short. If any drop short exceeds a preset duration period, the consumable electrode is rapidly retracted a predetermined distance to prevent bonding of the consumable electrode to the molten remelt.

  3. Modular high-voltage bias generator powered by dual-looped self-adaptive wireless power transmission.

    PubMed

    Xie, Kai; Huang, An-Feng; Li, Xiao-Ping; Guo, Shi-Zhong; Zhang, Han-Lu

    2015-04-01

    We proposed a modular high-voltage (HV) bias generator powered by a novel transmitter-sharing inductive coupled wireless power transmission technology, aimed to extend the generator's flexibility and configurability. To solve the problems caused through an uncertain number of modules, a dual-looped self-adaptive control method is proposed that is capable of tracking resonance frequency while maintaining a relatively stable induction voltage for each HV module. The method combines a phase-locked loop and a current feedback loop, which ensures an accurate resonance state and a relatively constant boost ratio for each module, simplifying the architecture of the boost stage and improving the total efficiency. The prototype was built and tested. The input voltage drop of each module is less than 14% if the module number varies from 3 to 10; resonance tracking is completed within 60 ms. The efficiency of the coupling structure reaches up to 95%, whereas the total efficiency approaches 73% for a rated output. Furthermore, this technology can be used in various multi-load wireless power supply applications.

  4. VOLTAGE REGULATOR

    DOEpatents

    Von Eschen, R.L.; Scheele, P.F.

    1962-04-24

    A transistorized voltage regulator which provides very close voitage regulation up to about 180 deg F is described. A diode in the positive line provides a constant voltage drop from the input to a regulating transistor emitter. An amplifier is coupled to the positive line through a resistor and is connected between a difference circuit and the regulating transistor base which is negative due to the difference in voltage drop across thc diode and the resistor so that a change in the regulator output causes the amplifier to increase or decrease the base voltage and current and incrcase or decrease the transistor impedance to return the regulator output to normal. (AEC)

  5. Regulation of the Output Voltage of an Inverter in Case of Load Variation

    NASA Astrophysics Data System (ADS)

    Diouri, Omar; Errahimi, Fatima; Es-Sbai, Najia

    2018-05-01

    In a DC/AC photovoltaic application, the stability of the output voltage of the inverter plays a very important role in the electrical systems. Such a photovoltaic system is constituted by an inverter, which makes it possible to convert the continuous energy to the alternative energy used in systems which operate under a voltage of 230V. The output of this inverter can be connected to a single load or more, at which time a second load is added in parallel with the first load. In this case, it proves a voltage drop at the output of the inverter. This problem influences the proper functioning of the electrical loads. Therefore, our contribution is to give a solution to this by compensating this voltage drop using a boost converter at the input of the inverter. This boost converter will play the role of the compensator that will provide the necessary voltage to the inverter in order to increase the voltage across the loads. But the use of this boost without controlling it is not enough because it generates a voltage that depends on the duty cycle of the control signal. To stabilize the output voltage of the inverter, we used a Proportional, Integral, and Derivative control (PID), which makes it possible to generate the necessary control signal for the voltage boost in order to have a good regulation of the output voltage of the inverter. Finally, we have solved the problem of the voltage drop even though there is loads variation.

  6. Method and apparatus for controlling electrode gap during vacuum consumable arc remelting

    DOEpatents

    Fisher, R.W.; Maroone, J.P.; Tipping, D.W.; Zanner, F.J.

    During vacuum consumable arc remelting the electrode gap between a consumable electrode and a pool of molten metal is difficult to control. The present invention monitors drop shorts by detecting a decrease in the voltage between the consumable electrode and molten pool. The drop shorts and their associated voltage reductions occur as repetitive pulses which are closely correlated to the electrode gap. Thus, the method and apparatus of the present invention controls electrode gap based upon drop shorts detected from the monitored anode-cathode voltage. The number of drop shorts are accumulated, and each time the number of drop shorts reach a predetermined number, the average period between drop shorts is calculated from this predetermined number and the time in which this number is accumulated. This average drop short period is used in a drop short period electrode gap model which determines the actual electrode gap from the drop short. The actual electrode gap is then compared with a desired electrode gap which is selected to produce optimum operating conditions and the velocity of the consumable error is varied based upon the gap error. The consumable electrode is driven according to any prior art system at this velocity. In the preferred embodiment, a microprocessor system is utilized to perform the necessary calculations and further to monitor the duration of each drop short. If any drop short exceeds a preset duration period, the consumable electrode is rapidly retracted a predetermined distance to prevent bonding of the consumable electrode to the molten remelt.

  7. Research on the Control Strategy for Grid-side Converter of PWM Doubly Fed Induction Wind Power Generators

    NASA Astrophysics Data System (ADS)

    Liu, Yifang; Wang, Zhijie; Li, Renfu; Jiang, Xiuchen; Sheng, Gehao; Liu, Tianyu; Liu, Sanming

    2017-05-01

    When the grid voltage drop, over current of transient rotor and over voltage may damage the power electronic devices. The attenuation of electromagnetic torque will lead to speed up. This paper proposes an improved feed-forward control strategy and its application in the PWM converter. When the PWM converter on voltage drops, bus voltage will be more stable. So over current problems of the DFIG rotor side can be reduced, and it also can improve voltage regulation speed of the DC bus voltage and reduce the oscillation amplitude. Furthermore, the stability of doubly fed wind generator system can be improved. The simulation results verify the validity of the modified control strategy.

  8. Affordable Acoustic Disdrometer: Design, Calibration, Tests

    NASA Astrophysics Data System (ADS)

    van de Giesen, N.; Degen, C.; Hut, R.

    2009-12-01

    It would be a hydrological understatement to say that measuring rainfall correctly is important. Recent years have seen important lowering of the costs of raingauges capable of measuring rainfall intensities. Such raingauges are typically tipping bucket raingauges, connected to an event logger. Costs for such a raingauge are about 100. Accuracy is not always very high, especially during high intensity storms. The moving parts make them vulnerable to slight disruptions such as insects. We set out to design a raingauge without moving parts and at a better price/quality ratio than existing raingauges. After testing several potential candidates, we settled on a very simple piezo ceramic element, which measures the impact of single drops. Such an element costs around 1. The impact of each drop causes an acoustic signal that is transformed into a voltage. A typical impact gives an upswing of up to 1 V and the ringing lasts about 50 ms. With a surface area of about 20 cm2, there is almost never overlap between the signals of different drops. The basic assumption is that each drop will have reached terminal velocity and that the total energy of the impact can, thereby, be related to drop size. We calibrated this acoustic disdrometer by letting drops of different size fall on the disdrometer. A very encouraging calibration curve was obtained in this way. Further testing consisted of comparisons during rainstorms between the acoustic disdrometer and standard tipping bucket raingauges. During intensive storms, the acoustic disdrometer gave results that were very close to those of a nearby totaling raingauge. The signal of the tipping bucket raingauges was clearly saturated as these were not capable of keeping up with the rain. During low intensity events, tipping bucket raingauges performed better as drops too small to detect by the acoustic disdrometer became a significant part of the total rainfall. In first instance, a simple MP3 player with recording functionality ($50) was used as datalogger and processing was performed with a Matlab script. Presently, processing is done on-board of a simple custom built logger that logs the time and total energy of each drop. Post-processing converts the total energy to drop size and corrects for missing small drops by fitting the pdf’s to known raindrop distributions.

  9. Silicon Carbide Diodes Characterization at High Temperature and Comparison With Silicon Devices

    NASA Technical Reports Server (NTRS)

    Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Gardner, Brent G.; Adams, Jerry D., Jr.

    2004-01-01

    Commercially available silicon carbide (SiC) Schottky diodes from different manufacturers rated at 200, 300, 600, and 1200 V, were electrically tested and characterized as a function of temperature up to 300 C. Electrical tests included both steady state and dynamic tests. Steady state tests produced forward and reverse I-V characteristic curves. Transient tests evaluated the switching performance of the diodes in either a hard-switched DC to DC buck converter or a half-bridge boost converter. For evaluation and comparison purposes, the same tests were performed with current state-of-the-art ultra fast silicon (Si) pn-junction diodes of similar ratings and also a Si Schottky diode. The comparisons made were forward voltage drop at rated current, reverse current at rated voltage, and turn-off peak reverse recovery current and reverse recovery time. In addition, efficiency measurements were taken for the buck DC to DC converter using both the SiC Schottky diodes and the Si pn-junction diodes at different temperatures and frequencies. The test results showed that at high temperature, the forward voltage drop for SiC Schottky diodes is higher than the forward drop of the ultra fast Si pn-junction diodes. As the temperature increased, the forward voltage drop of the SiC Schottky increased while for the ultra fast Si pn-junction diodes, the forward voltage drop decreased as temperature increased. For the elevated temperature steady state reverse voltage tests, the SiC Schottky diodes showed low leakage current at their rated voltage. Likewise, for the transient tests, the SiC Schottky diodes displayed low reverse recovery currents over the range of temperatures tested. Conversely, the Si pn-junction diodes showed increasing peak reverse current values and reverse recovery times with increasing temperature. Efficiency measurements in the DC to DC buck converter showed the advantage of the SiC Schottky diodes over the ultra fast Si pn-junction diodes, especially at the higher temperatures and higher frequencies.

  10. Voltage Drop in a Ferroelectric Single Layer Capacitor by Retarded Domain Nucleation.

    PubMed

    Kim, Yu Jin; Park, Hyeon Woo; Hyun, Seung Dam; Kim, Han Joon; Kim, Keum Do; Lee, Young Hwan; Moon, Taehwan; Lee, Yong Bin; Park, Min Hyuk; Hwang, Cheol Seong

    2017-12-13

    Ferroelectric (FE) capacitor is a critical electric component in microelectronic devices. Among many of its intriguing properties, the recent finding of voltage drop (V-drop) across the FE capacitor while the positive charges flow in is especially eye-catching. This finding was claimed to be direct evidence that the FE capacitor is in negative capacitance (NC) state, which must be useful for (infinitely) high capacitance and ultralow voltage operation of field-effect transistors. Nonetheless, the NC state corresponds to the maximum energy state of the FE material, so it has been widely accepted in the community that the material alleviates that state by forming ferroelectric domains. This work reports a similar V-drop effect from the 150 nm thick epitaxial BaTiO 3 ferroelectric thin film, but the interpretation was completely disparate; the V-drop can be precisely simulated by the reverse domain nucleation and propagation of which charge effect cannot be fully compensated for by the supplied charge from the external charge source. The disappearance of the V-drop effect was also observed by repeated FE switching only up to 10 cycles, which can hardly be explained by the involvement of the NC effect. The retained reverse domain nuclei even after the subsequent poling can explain such behavior.

  11. Power supply

    DOEpatents

    Yakymyshyn, Christopher Paul; Hamilton, Pamela Jane; Brubaker, Michael Allen

    2007-12-04

    A modular, low weight impedance dropping power supply with battery backup is disclosed that can be connected to a high voltage AC source and provide electrical power at a lower voltage. The design can be scaled over a wide range of input voltages and over a wide range of output voltages and delivered power.

  12. Spectrometer system for optical reflectance measurements

    NASA Technical Reports Server (NTRS)

    Phillipps, Patrick G. (Inventor); Soller, Babs R. (Inventor); Parker, Michael S. (Inventor)

    2007-01-01

    A spectrometer system includes a thermal light source for illuminating a sample, where the thermal light source includes a filament that emits light when heated. The system additionally includes a spectrograph for measuring a light spectrum from the sample and an electrical circuit for supplying electrical current to the filament to heat the filament and for controlling a resistance of the filament. The electrical circuit includes a power supply that supplies current to the filament, first electrical components that sense a current through the filament, second electrical components that sense a voltage drop across the filament, third electrical components that compare a ratio of the sensed voltage drop and the sensed current with a predetermined value, and fourth electrical components that control the current through the filament or the voltage drop across the filament to cause the ratio to equal substantially the predetermined value.

  13. Voltage Drop Compensation Method for Active Matrix Organic Light Emitting Diode Displays

    NASA Astrophysics Data System (ADS)

    Choi, Sang-moo; Ryu, Do-hyung; Kim, Keum-nam; Choi, Jae-beom; Kim, Byung-hee; Berkeley, Brian

    2011-03-01

    In this paper, the conventional voltage drop compensation methods are reviewed and the novel design and driving scheme, the advanced power de-coupled (aPDC) driving method, is proposed to effectively compensate the voltage IR drop of active matrix light emitting diode (AMOLED) displays. The advanced PDC driving scheme can be applied to general AMOLED pixel circuits that have been developed with only minor modification or without requiring modification in pixel circuit. A 14-in. AMOLED panel with the aPDC driving scheme was fabricated. Long range uniformity (LRU) of the 14-in. AMOLED panel was improved from 43% without the aPDC driving scheme, to over 87% at the same brightness by using the scheme and the layout complexity of the panel with new design scheme is less than that of the panel with the conventional design scheme.

  14. Ultrafast Power Processor for Smart Grid Power Module Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MAITRA, ARINDAM; LITWIN, RAY; lai, Jason

    This project’s goal was to increase the switching speed and decrease the losses of the power semiconductor devices and power switch modules necessary to enable Smart Grid energy flow and control equipment such as the Ultra-Fast Power Processor. The primary focus of this project involves exploiting the new silicon-based Super-GTO (SGTO) technology and build on prototype modules already being developed. The prototype super gate-turn-off thyristor (SGTO) has been tested fully under continuously conducting and double-pulse hard-switching conditions for conduction and switching characteristics evaluation. The conduction voltage drop measurement results indicate that SGTO has excellent conduction characteristics despite inconsistency among somemore » prototype devices. Tests were conducted with two conditions: (1) fixed gate voltage and varying anode current condition, and (2) fixed anode current and varying gate voltage condition. The conduction voltage drop is relatively a constant under different gate voltage condition. In terms of voltage drop as a function of the load current, there is a fixed voltage drop about 0.5V under zero current condition, and then the voltage drop is linearly increased with the current. For a 5-kV voltage blocking device that may operate under 2.5-kV condition, the projected voltage drop is less than 2.5 V under 50-A condition, or 0.1%. If the device is adopted in a converter operating under soft-switching condition, then the converter can achieve an ultrahigh efficiency, typically above 99%. The two-pulse switching test results indicate that SGTO switching speed is very fast. The switching loss is relatively low as compared to that of the insulated-gate-bipolar-transistors (IGBTs). A special phenomenon needs to be noted is such a fast switching speed for the high-voltage switching tends to create an unexpected Cdv/dt current, which reduces the turn-on loss because the dv/dt is negative and increases the turn-off loss because the dv/dt is positive. As a result, the turn-on loss at low current is quite low, and the turn-off loss at low current is relatively high. The phenomenon was verified with junction capacitance measurement along with the dv/dt calculation. Under 2-kV test condition, the turn-on and turn-off losses at 25-A is about 3 and 9 mJ, respectively. As compared to a 4.5-kV, 60-A rated IGBT, which has turn-on and turn-off losses about 25 and 20 mJ under similar test condition, the SGTO shows significant switching loss reduction. The switching loss depends on the switching frequency, but under hard-switching condition, the SGTO is favored to the IGBT device. The only concern is during low current turn-on condition, there is a voltage bump that can translate to significant power loss and associated heat. The reason for such a current bump is not known from this study. It is necessary that the device manufacturer perform though test and provide the answer so the user can properly apply SGTO in pulse-width-modulated (PWM) converter and inverter applications.« less

  15. Integrating preconcentrator heat controller

    DOEpatents

    Bouchier, Francis A.; Arakaki, Lester H.; Varley, Eric S.

    2007-10-16

    A method and apparatus for controlling the electric resistance heating of a metallic chemical preconcentrator screen, for example, used in portable trace explosives detectors. The length of the heating time-period is automatically adjusted to compensate for any changes in the voltage driving the heating current across the screen, for example, due to gradual discharge or aging of a battery. The total deposited energy in the screen is proportional to the integral over time of the square of the voltage drop across the screen. Since the net temperature rise, .DELTA.T.sub.s, of the screen, from beginning to end of the heating pulse, is proportional to the total amount of heat energy deposited in the screen during the heating pulse, then this integral can be calculated in real-time and used to terminate the heating current when a pre-set target value has been reached; thereby providing a consistent and reliable screen temperature rise, .DELTA.T.sub.s, from pulse-to-pulse.

  16. Rain Drop Charge Sensor

    NASA Astrophysics Data System (ADS)

    S, Sreekanth T.

    begin{center} Large Large Rain Drop Charge Sensor Sreekanth T S*, Suby Symon*, G. Mohan Kumar (1) , S. Murali Das (2) *Atmospheric Sciences Division, Centre for Earth Science Studies, Thiruvananthapuram 695011 (1) D-330, Swathi Nagar, West Fort, Thiruvananthapuram 695023 (2) Kavyam, Manacaud, Thiruvananthapuram 695009 begin{center} ABSTRACT To study the inter-relations with precipitation electricity and precipitation microphysical parameters a rain drop charge sensor was designed and developed at CESS Electronics & Instrumentation Laboratory. Simultaneous measurement of electric charge and fall speed of rain drops could be done using this charge sensor. A cylindrical metal tube (sensor tube) of 30 cm length is placed inside another thick metal cover opened at top and bottom for electromagnetic shielding. Mouth of the sensor tube is exposed and bottom part is covered with metal net in the shielding cover. The instrument is designed in such a way that rain drops can pass only through unhindered inside the sensor tube. When electrically charged rain drops pass through the sensor tube, it is charged to the same magnitude of drop charge but with opposite polarity. The sensor tube is electrically connected the inverted input of a current to voltage converter operational amplifier using op-amp AD549. Since the sensor is electrically connected to the virtual ground of the op-amp, the charge flows to the ground and the generated current is converted to amplified voltage. This output voltage is recorded using a high frequency (1kHz) voltage recorder. From the recorded pulse, charge magnitude, polarity and fall speed of rain drop are calculated. From the fall speed drop diameter also can be calculated. The prototype is now under test running at CESS campus. As the magnitude of charge in rain drops is an indication of accumulated charge in clouds in lightning, this instrument has potential application in the field of risk and disaster management. By knowing the charge magnitude of initial drops from a precipitation event, gross cloud charge can be estimated and necessary precautions can be taken during convective cloud events. Being a site of high lightning incidence in tropics, Kerala state is affected in India and calls for much attention in lightning hazards mitigation. Installing this charge sensor and atmospheric electric field mill, an attempt to a better warning system can be attempted.

  17. Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

    NASA Technical Reports Server (NTRS)

    Burns, Bradley M.; Blalock, Norman N.

    2010-01-01

    A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the switch and the inductor configuration. In the fault condition, both the resistor and the inductor react immediately. The resistor reacts by allowing more current to flow and dropping the voltage. Initially, the inductor reacts by dropping the voltage, and then by not allowing the current to change. When the comparator detects the drop in voltage, it opens the switch, thus preventing any further current flow. The inductor alone is not sufficient protection, because after the voltage drop has settled, the inductor would then allow the current to change, in this example, the current would be 3.7 A. In the fault condition, the resistor is flowing 200 mA until the fuse blows (anywhere from 1 ms to 100 s), while the switch and inductor combination is flowing about 2 A test current while monitoring for the fault to be corrected. Finally, as an additional safety feature, the circuit can be configured to hold the switch opened until both the load and source are disconnected.

  18. Gas discharge visualization evaluation of ultramolecular doses of homeopathic medicines under blinded, controlled conditions.

    PubMed

    Bell, Iris R; Lewis, Daniel A; Brooks, Audrey J; Lewis, Sabrina E; Schwartz, Gary E

    2003-02-01

    To determine the feasibility of using a computerized biophysical method, gas discharge visualization (GDV), to differentiate ultramolecular doses of homeopathic remedies from solvent controls and from each other. Blinded, randomized assessment of four split samples each of 30c potencies of three homeopathic remedies from different kingdoms, for example, Natrum muriaticum (mineral), Pulsatilla (plant), and Lachesis (animal), dissolved in a 20% alcohol-water solvent versus two different control solutions (that is, solvent with untreated lactose/sucrose pellets and unsuccussed solvent alone). GDV measurements, involving application of a brief electrical impulse at four different voltage levels, were performed over 10 successive images on each of 10 drops from each bottle (total 400 images per test solution per voltage). The dependent variables were the quantified image characteristics of the liquid drops (form coefficient, area, and brightness) from the resultant burst of electron-ion emission and optical radiation in the visual and ultraviolet ranges. The procedure generated measurable images at the two highest voltage levels. At 17 kV, the remedies exhibited overall lower image parameter values compared with solvents (significant for Pulsatilla and Lachesis), as well as differences from solvents in fluctuations over repeated images (exposures to the same voltage). At 24 kV, other patterns emerged, with individual remedies showing higher or lower image parameters compared with other remedies and the solvent controls. GDV technology may provide an electromagnetic probe into the properties of homeopathic remedies as distinguished from solvent controls. However, the present findings also highlight the need for additional research to evaluate factors that may affect reproducibility of results.

  19. MHD (magnetohydrodynamics) channel development: Quarterly report for January 1987-March 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-04-01

    During the report period several slag doping tests were performed. Four of these tests are described in this report. The results were generally encouraging. Four dopants were investigated: Fe/sub 2/O/sub 3/, Fe/sub 3/O/sub 4/, MnO, and CrO/sub 2/. All but the CrO/sub 2/ proved effective within some range of dopant flow rate. At flow rates above or below this range none of the dopants were desirable. The proper ranges for each of the dopants was coarsely mapped in these experiments. When the dopants were injected directly on the anode wall a power increase was observed. This indicates a possible reductionmore » in the voltage drop due to the presence of the dopant. No power gain or loss was observed when the dopant was injected on the cathode wall. However, inter-cathode voltages were observed to spread more uniformly along the wall. High voltages decreased and low voltages increased. This result should help to reduce wear on the cathodes and their neighboring wall elements by reducing the local electrical field. Current control circuits were tested on both MK VI and MK VII type generators and components for consolidation circuits ordered. Solutions to waste disposal problems created by the implementation of new environmental regulations are being investigated. The MHD generator data from the CDIF 87-SEED-1, 87-SEED-2, and 87-SEED-3 tests have been analyzed and the results are presented in this report. The results of the SIDA model presented in this quarterly report are obtained by assuming a constant boundary layer voltage drop. Variations in the boundary layer voltage drop as a result of diagonal loading changes, iron oxide addition, or seeding rates changes were not considered. Corrections for the effects of ..delta..V/sub b1/ will be made to the results of SIDA when the voltage drop measurements become available.« less

  20. Modeling the voltage loss mechanisms in lithium-sulfur cells: the importance of electrolyte resistance and precipitation kinetics.

    PubMed

    Zhang, Teng; Marinescu, Monica; O'Neill, Laura; Wild, Mark; Offer, Gregory

    2015-09-21

    Understanding of the complex electrochemical, transport, and phase-change phenomena in Li-S cells requires experimental characterization in tandem with mechanistic modeling. However, existing Li-S models currently contradict some key features of experimental findings, particularly the evolution of cell resistance during discharge. We demonstrate that, by introducing a concentration-dependent electrolyte conductivity, the correct trends in voltage drop due to electrolyte resistance and activation overpotentials are retrieved. In addition, we reveal the existence of an often overlooked potential drop mechanism in the low voltage-plateau which originates from the limited rate of Li2S precipitation.

  1. Lithium-cupric sulfide cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cuesta, A.J.; Bump, D.D.

    1980-01-01

    Lithium cells have become the primary power source for cardiac pacemakers due to their reliability and longevity at low current drain rates. A lithium-cupric sulfide cell was developed which makes maximum use of the shape of a pacemaker's battery compartment. The cell has a stable voltage throughout 90% of its lifetime. It then drops to a second stable voltage before depletion. The voltage drop creates a small decrease in pacemaker rate, which alerts the physician to replace the pacemaker. No loss of capacity due to self-discharge as been seen to date, and cells have proven to be safe under extrememore » conditions. 2 refs.« less

  2. 5.0 kV breakdown-voltage vertical GaN p-n junction diodes

    NASA Astrophysics Data System (ADS)

    Ohta, Hiroshi; Hayashi, Kentaro; Horikiri, Fumimasa; Yoshino, Michitaka; Nakamura, Tohru; Mishima, Tomoyoshi

    2018-04-01

    A high breakdown voltage of 5.0 kV has been achieved for the first time in vertical GaN p-n junction diodes by using our newly developed guard-ring structures. A resistance device was inserted between the main diode portion and the guard-ring portion in a ring-shaped p-n diode to generate a voltage drop over the resistance device by leakage current flowing through the guard-ring portion under negatively biased conditions before breakdown. The voltage at the outer mesa edge of the guard-ring portion, where the electric field intensity is highest and the destructive breakdown usually occurs, is decreased by the voltage drop, so the electric field concentration in the portion is reduced. By adopting this structure, the breakdown voltage (V B) is raised by about 200 V. Combined with a low measured on-resistance (R on) of 1.25 mΩ cm2, Baliga’s figure of merit (V\\text{B}2/R\\text{on}) was as high as 20 GW/cm2.

  3. Optimal line drop compensation parameters under multi-operating conditions

    NASA Astrophysics Data System (ADS)

    Wan, Yuan; Li, Hang; Wang, Kai; He, Zhe

    2017-01-01

    Line Drop Compensation (LDC) is a main function of Reactive Current Compensation (RCC) which is developed to improve voltage stability. While LDC has benefit to voltage, it may deteriorate the small-disturbance rotor angle stability of power system. In present paper, an intelligent algorithm which is combined by Genetic Algorithm (GA) and Backpropagation Neural Network (BPNN) is proposed to optimize parameters of LDC. The objective function proposed in present paper takes consideration of voltage deviation and power system oscillation minimal damping ratio under multi-operating conditions. A simulation based on middle area of Jiangxi province power system is used to demonstrate the intelligent algorithm. The optimization result shows that coordinate optimized parameters can meet the multioperating conditions requirement and improve voltage stability as much as possible while guaranteeing enough damping ratio.

  4. O the Electrohydrodynamics of Drop Extraction from a Conductive Liquid Meniscus

    NASA Astrophysics Data System (ADS)

    Wright, Graham Scott

    This thesis is concerned with the use of an electric field in the extraction of liquid drops from a capillary orifice or nozzle. The motivating application is ink jet printing. Current drop-on-demand ink jets use pressure pulses to eject drops. Literature on electrostatic spraying suggests that by using an electric field, drops could be produced with a wider range of sizes and speeds than is possible with pressure ejection. Previous efforts to apply electric spraying to printing or similar selective coating tasks have taken an experimental approach based on steady or periodic spraying phenomena, without attempting cycle -by-cycle drop control. The centerpiece of this thesis is a simulation tool developed to explore such possibilities. A simplified analytic model is developed as a preliminary step, yielding formulas for force and time scales that provide an appropriate basis for nondimensionalization of the governing differential equations; important dimensionless parameters are identified. The complete self-consistent model permits simulation of meniscus behavior under time -varying applied voltage or pressure, with the electric field solution continually updated as the surface changes shape. The model uses a quasi-one-dimensional hydrodynamic formulation and a two-dimensional axisymmetric boundary element solution for the electric field. The simulation is checked against experimental results for meniscus stability, resonant modes, and drop emission under electric field. The simulation faithfully captures important qualitative aspects of meniscus behavior and gives reasonable quantitative agreement within the limitations of the model. Insights gained in simulation point the way to a successful laboratory demonstration of drop extraction using a shaped voltage pulse. Drop size control is pursued in simulation using pressure and voltage pulses both alone and in combination, for both light and viscous liquids. Combining pressure and field pulses is shown to be synergistic; drop volumes over a range of 175 to 1 were obtained, while maintaining good drop velocity. The differing strategies for obtaining large and small drops are described. Drop extraction using only the electric field is more difficult, but promising approaches remain open.

  5. Memristor-integrated voltage-stabilizing supercapacitor system.

    PubMed

    Liu, Bin; Liu, Boyang; Wang, Xianfu; Wu, Xinghui; Zhao, Wenning; Xu, Zhimou; Chen, Di; Shen, Guozhen

    2014-08-06

    Voltage-stabilized supercapacitors: A single supercapacitor formed with PCBM/Pt/IPS nanorod-array electrodes is designed and delivers enhanced areal capacitance, capacitance retention, and excellent electrical stability under bending, while a significant voltage-decrease is observed during the discharging process. Once integrated with the memristor, the memristor-integrated supercapacitor systems deliver an extremely low voltage-drop, indicating greatly enhanced voltage-stabilizing features. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Hybrid switch for resonant power converters

    DOEpatents

    Lai, Jih-Sheng; Yu, Wensong

    2014-09-09

    A hybrid switch comprising two semiconductor switches connected in parallel but having different voltage drop characteristics as a function of current facilitates attainment of zero voltage switching and reduces conduction losses to complement reduction of switching losses achieved through zero voltage switching in power converters such as high-current inverters.

  7. Fluidization quality analyzer for fluidized beds

    DOEpatents

    Daw, C. Stuart; Hawk, James A.

    1995-01-01

    A control loop and fluidization quality analyzer for a fluidized bed utilizes time varying pressure drop measurements. A fast-response pressure transducer measures the overall bed pressure drop, or over some segment of the bed, and the pressure drop signal is processed to produce an output voltage which changes with the degree of fluidization turbulence.

  8. Fluidization quality analyzer for fluidized beds

    DOEpatents

    Daw, C.S.; Hawk, J.A.

    1995-07-25

    A control loop and fluidization quality analyzer for a fluidized bed utilizes time varying pressure drop measurements. A fast-response pressure transducer measures the overall bed pressure drop, or over some segment of the bed, and the pressure drop signal is processed to produce an output voltage which changes with the degree of fluidization turbulence. 9 figs.

  9. Investigation of an Aberrant Cell Voltage During the Filling of a Large Lithium Thionyl Chloride Cell

    NASA Technical Reports Server (NTRS)

    Thaller, Lawrence H.; Quinzio, Michael V.

    1997-01-01

    The investigation of an aberrant cell voltage during the filling of a large lithium thionyl chloride cell summary is at: an aberrant voltage trace was noted during the review of cell filling data; incident was traced to an interruption during filling; experimentation suggested oxidizable sites within the carbon electrode were responsible for the drop in voltage; the voltage anomaly could be reproduced by interrupting the filling of similar cells; and anomalous voltage dip was not due to a short.

  10. Off-set stabilizer for comparator output

    DOEpatents

    Lunsford, James S.

    1991-01-01

    A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.

  11. Experimental Analysis of Voltage Drop Compensation in a DC Electrified Railway by Introducing an Energy Storage System Incorporating EDLCs

    NASA Astrophysics Data System (ADS)

    Konishi, Takeshi; Hase, Shin-Ichi; Nakamichi, Yoshinobu; Nara, Hidetaka; Uemura, Tadashi

    Interest has been shown in the concept of an energy storage system aimed at leveling load and improving energy efficiency by charging during vehicle regeneration and discharging during running. Such a system represents an efficient countermeasure against pantograph point voltage drop, power load fluctuation and regenerative power loss. We selected an EDLC model as an energy storage medium and a step-up/step-down chopper as a power converter to exchange power between the storage medium and overhead lines. Basic verification was conducted using a mini-model for DC 400V, demonstrating characteristics suitable for its use as an energy storage system. Based on these results, an energy storage system was built for DC 600V and a verification test conducted in conjunction with the Enoshima Electric Railway Co. Ltd. This paper gives its experimental analysis of voltage drop compensation in a DC electrified railway and some discussions based on the test.

  12. Development of Voltage Regulation Plan by Composing Subsystem with the SFES for DC On-line Electric Vehicle

    NASA Astrophysics Data System (ADS)

    Jung, S.; Lee, J. H.; Yoon, M.; Lee, H.; Jang, G.

    The study of the application process of the relatively small size 'Superconducting Flywheel Energy Storage (SFES)' system is conducted to regulate voltage fluctuation of the DC On-Line Electric Vehicle (OLEV) system, which is designed by using DC power system network. It is recommended to construct the power conversion system nearby the substation because the charging system is under the low voltage. But as the system is usually built around urban area and it makes hard to construct the subsystems at every station, voltage drop can occur in power supply inverter that is some distance from the substation. As the alternative of this issue, DC distribution system is recently introduced and has possibility to solve the above issue. In this paper, SFES is introduced to solve the voltage drop under the low voltage distribution system by using the concept of the proposed DC OLEV which results in building the longer distance power supply system. The simulation to design the SFES by using DC power flow analysis is carried out and it is verified in this paper.

  13. Development and fabrication of a high current, fast recovery power diode

    NASA Technical Reports Server (NTRS)

    Berman, A. H.; Balodis, V.; Devance, D. C.; Gaugh, C. E.; Karlsson, E. A.

    1983-01-01

    A high voltage (VR = 1200 V), high current (IF = 150 A), fast recovery ( 700 ns) and low forward voltage drop ( 1.5 V) silicon rectifier was designed and the process developed for its fabrication. For maximum purity, uniformity and material characteristic stability, neutron transmutation n-type doped float zone silicon is used. The design features a hexagonal chip for maximum area utilization of space available in the DO-8 diode package, PIN diffused junction structure with deep diffused D(+) anode and a shallow high concentration n(+) cathode. With the high temperature glass passivated positive bevel mesa junction termination, the achieved blocking voltage is close to the theoretical limit of the starting material. Gold diffusion is used to control the lifetime and the resulting effect on switching speed and forward voltage tradeoff. For solder reflow assembly, trimetal (Al-Ti-Ni) contacts are used. The required major device electrical characteristics were achieved. Due to the tradeoff nature of forward voltage drop and reverse recovery time, a compromise was reached for these values.

  14. Analog circuit for controlling acoustic transducer arrays

    DOEpatents

    Drumheller, Douglas S.

    1991-01-01

    A simplified ananlog circuit is presented for controlling electromechanical transducer pairs in an acoustic telemetry system. The analog circuit of this invention comprises a single electrical resistor which replaces all of the digital components in a known digital circuit. In accordance with this invention, a first transducer in a transducer pair of array is driven in series with the resistor. The voltage drop across this resistor is then amplified and used to drive the second transducer. The voltage drop across the resistor is proportional and in phase with the current to the transducer. This current is approximately 90 degrees out of phase with the driving voltage to the transducer. This phase shift replaces the digital delay required by the digital control circuit of the prior art.

  15. New modeling method for the dielectric relaxation of a DRAM cell capacitor

    NASA Astrophysics Data System (ADS)

    Choi, Sujin; Sun, Wookyung; Shin, Hyungsoon

    2018-02-01

    This study proposes a new method for automatically synthesizing the equivalent circuit of the dielectric relaxation (DR) characteristic in dynamic random access memory (DRAM) without frequency dependent capacitance measurement. Charge loss due to DR can be observed by a voltage drop at the storage node and this phenomenon can be analyzed by an equivalent circuit. The Havariliak-Negami model is used to accurately determine the electrical characteristic parameters of an equivalent circuit. The DRAM sensing operation is performed in HSPICE simulations to verify this new method. The simulation demonstrates that the storage node voltage drop resulting from DR and the reduction in the sensing voltage margin, which has a critical impact on DRAM read operation, can be accurately estimated using this new method.

  16. Analysis Impact of Distributed Generation Injection to Profile of Voltage and Short-Circuit Fault in 20 kV Distribution Network System

    NASA Astrophysics Data System (ADS)

    Mulyadi, Y.; Sucita, T.; Rahmawan, M. D.

    2018-01-01

    This study was a case study in PT. PLN (Ltd.) APJ Bandung area with the subject taken was the installation of distributed generation (DG) on 20-kV distribution channels. The purpose of this study is to find out the effect of DG to the changes in voltage profile and three-phase short circuit fault in the 20-kV distribution system with load conditions considered to be balanced. The reason for this research is to know how far DG can improve the voltage profile of the channel and to what degree DG can increase the three-phase short circuit fault on each bus. The method used in this study was comparing the simulation results of power flow and short-circuit fault using ETAP Power System software with manual calculations. The result obtained from the power current simulation before the installation of DG voltage was the drop at the end of the channel at 2.515%. Meanwhile, the three-phase short-circuit current fault before the DG installation at the beginning of the channel was 13.43 kA. After the installation of DG with injection of 50%, DG power obtained voltage drop at the end of the channel was 1.715% and the current fault at the beginning network was 14.05 kA. In addition, with injection of 90%, DG power obtained voltage drop at the end of the channel was 1.06% and the current fault at the beginning network was 14.13%.

  17. Low-Voltage Bypass Device

    NASA Technical Reports Server (NTRS)

    Wilson, J. P.

    1994-01-01

    Improved bypass device provides low-resistance current shunt around low-voltage power cell when cell fails in open-circuit condition during operation. In comparison with older bypass devices for same application, this one weighs less, generates less heat, and has lower voltage drop (less resistance). Bypass device connected in parallel with power cell. Draws very little current during normal operation of cell.

  18. HIGH VOLTAGE GENERATOR

    DOEpatents

    Zito, G.V.

    1959-04-21

    This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

  19. Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

    NASA Technical Reports Server (NTRS)

    Patterson, Richard; Hammoud, Ahmad

    2010-01-01

    The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

  20. Virtual welding equipment for simulation of GMAW processes with integration of power source regulation

    NASA Astrophysics Data System (ADS)

    Reisgen, Uwe; Schleser, Markus; Mokrov, Oleg; Zabirov, Alexander

    2011-06-01

    A two dimensional transient numerical analysis and computational module for simulation of electrical and thermal characteristics during electrode melting and metal transfer involved in Gas-Metal-Arc-Welding (GMAW) processes is presented. Solution of non-linear transient heat transfer equation is carried out using a control volume finite difference technique. The computational module also includes controlling and regulation algorithms of industrial welding power sources. The simulation results are the current and voltage waveforms, mean voltage drops at different parts of circuit, total electric power, cathode, anode and arc powers and arc length. We describe application of the model for normal process (constant voltage) and for pulsed processes with U/I and I/I-modulation modes. The comparisons with experimental waveforms of current and voltage show that the model predicts current, voltage and electric power with a high accuracy. The model is used in simulation package SimWeld for calculation of heat flux into the work-piece and the weld seam formation. From the calculated heat flux and weld pool sizes, an equivalent volumetric heat source according to Goldak model, can be generated. The method was implemented and investigated with the simulation software SimWeld developed by the ISF at RWTH Aachen University.

  1. Constant-Current Source For Measuring Low Resistances

    NASA Technical Reports Server (NTRS)

    Toomath, Robert L.

    1996-01-01

    Constant-current source constructed for measuring electrical resistances up to few ohms in power-supply equipment. By setting current at 1 A and measuring resulting voltage drop across item under test, one obtains voltage reading numerically equal to resistance in ohms.

  2. Epitaxial thinning process

    NASA Technical Reports Server (NTRS)

    Siegel, C. M. (Inventor)

    1984-01-01

    A method is described for thinning an epitaxial layer of a wafer that is to be used in producing diodes having a specified breakdown voltage and which also facilitates the thinning process. Current is passed through the epitaxial layer, by connecting a current source between the substrate of the wafer and an electrolyte in which the wafer is immersed. When the wafer is initially immersed, the voltage across the wafer initially drops and then rises at a steep rate. When light is applied to the wafer the voltage drops, and when the light is interrupted the voltage rises again. These changes in voltage, each indicate the breakdown voltage of a Schottky diode that could be prepared from the wafer at that time. The epitaxial layer is thinned by continuing to apply current through the wafer while it is immersed and light is applied, to form an oxide film and when the oxide film is thick the wafer can then be cleaned of oxide and the testing and thinning continued. Uninterrupted thinning can be achieved by first forming an oxide film, and then using an electrolyte that dissolves the oxide about as fast as it is being formed, to limit the thickness of the oxide layer.

  3. New GaN Schottky barrier diode employing a trench on AlGaN/GaN heterostructure

    NASA Astrophysics Data System (ADS)

    Ha, Min-Woo; Lee, Seung-Chul; Choi, Young-Hwan; Kim, Soo-Seong; Yun, Chong-Man; Han, Min-Koo

    2006-10-01

    A new GaN Schottky barrier diode employing a trench structure, which is proposed and fabricated, successfully decreases a forward voltage drop without sacrificing any other electric characteristics. The trench is located in the middle of Schottky contact during a mesa etch. The Schottky metal of Pt/Mo/Ti/Au is e-gun evaporated on the 300 nm-deep trench as well as the surface of the proposed GaN Schottky barrier diode. The trench forms the vertical Au Schottky contact and lateral Pt Schottky contact due to the evaporation sequence of Schottky metal. The forward voltage drops of the proposed diode and conventional one are 0.73 V and 1.25 V respectively because the metal work function (5.15 eV) of the vertical Au Schottky contact is considerably less than that of the lateral Pt Schottky contact (5.65 eV). The proposed diode exhibits the low on-resistance of 1.58 mΩ cm 2 while the conventional one exhibits 8.20 mΩ cm 2 due to the decrease of a forward voltage drop.

  4. Electrochemical measurements on a droplet using gold microelectrodes

    NASA Astrophysics Data System (ADS)

    Jenabi, Amin; Souri, Asma; Rastkhadiv, Ali

    2016-03-01

    Facile methods of ion recognition are important for the fabrication of electronic tongue systems. In this work, we demonstrate performing pulsed conductometry on microliter electrolyte droplets dropped on gold microelectrodes vapor deposited on soda lime glass slides. A droplet is dropped between two microelectrodes when a voltage waveform from a preprogramed power supply is applied on them. The temporal variation of the electric current passing through the droplet is recorded, digitized and stored. The obtained data are compared with the database formed out of the previous experiences for the classification of the sample electrolytes. It is shown that the shape of the voltage waveform is the important parameter of the process. We devised a method for the optimization of the voltage waveform profile for obtaining the maximum of discriminating information from the recorded current variations.

  5. High voltage DC power supply

    DOEpatents

    Droege, T.F.

    1989-12-19

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

  6. High voltage DC power supply

    DOEpatents

    Droege, Thomas F.

    1989-01-01

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  7. A study of electrostatic spring softening for dual-axis micromirror

    NASA Astrophysics Data System (ADS)

    Zhao, Yi; E H Tay, Francis; Zhou, Guangya; Siong Chau, Fook

    2006-08-01

    Electrostatic spring softening is an important characteristic of electrostatically actuated dual-axis micromirror, since it lowers the resonant frequencies. This paper presents an approach based on approximating the electrostatic forces by the first-order Taylor's series expansion to investigate this characteristic. The dual-axis micromirror studied in this paper has three motion modes, two torsional (about x- and y-axis, respectively) and one translational (about z-axis). The stiffnesses of all these modes are softened by a DC bias voltage applied to the mirror plate. The resonant frequencies are lowered with the increment of the bias voltage. The relationship of the bias voltage and the resonant frequencies of all the motion modes is derived. The analytical results show that the resonant frequency curves are affected by the capacitor geometries, i.e. the gap between the mirror plate and the electrodes and the electrodes size. The lowering curves drop slowly when the bias voltage is small. While for large bias voltage, the lowering curves drop rapidly. The experiment results are consistent with those obtained by the analytical approach.

  8. OBSAPS Data Acquisition System: Operator’s Manual and System Overview

    DTIC Science & Technology

    2011-05-01

    Explanation of Druck Voltage to Depth Conversion used during OBSAPS (April-May’11)   25   Druck  Pressure  sensor  conversion  from...for H-91, PA Voltage, PA Current and Sonobuoy and Druck pressure sensor analog inputs. 6. Software settable thresholds for H-91, PA Voltage, PA...17. Custom dry side box for Druck Pressure Sensor supply voltage and dropping resistor. 18. Battery 9-30VDC for supplying Druck power 19. Druck PTX

  9. Electrowetting on semiconductors

    NASA Astrophysics Data System (ADS)

    Palma, Cesar; Deegan, Robert

    2015-01-01

    Applying a voltage difference between a conductor and a sessile droplet sitting on a thin dielectric film separating it from the conductor will cause the drop to spread. When the conductor is a good metal, the change of the drop's contact angle due to the voltage is given by the Young-Lippmann (YL) equation. Here, we report experiments with lightly doped, single crystal silicon as the conductive electrode. We derive a modified YL equation that includes effects due to the semiconductor and contact line pinning. We show that light induces a non-reversible wetting transition, and that our model agrees well with our experimental results.

  10. Breath Figures under Electrowetting: Electrically Controlled Evolution of Drop Condensation Patterns

    NASA Astrophysics Data System (ADS)

    Baratian, Davood; Dey, Ranabir; Hoek, Harmen; van den Ende, Dirk; Mugele, Frieder

    2018-05-01

    We show that electrowetting (EW) with structured electrodes significantly modifies the distribution of drops condensing onto flat hydrophobic surfaces by aligning the drops and by enhancing coalescence. Numerical calculations demonstrate that drop alignment and coalescence are governed by the drop-size-dependent electrostatic energy landscape that is imposed by the electrode pattern and the applied voltage. Such EW-controlled migration and coalescence of condensate drops significantly alter the statistical characteristics of the ensemble of droplets. The evolution of the drop size distribution displays self-similar characteristics that significantly deviate from classical breath figures on homogeneous surfaces once the electrically induced coalescence cascades set in beyond a certain critical drop size. The resulting reduced surface coverage, coupled with earlier drop shedding under EW, enhances the net heat transfer.

  11. Analysis of a Van de Graaff Generator for EMP Direct Current Survivability Testing

    DTIC Science & Technology

    2013-03-01

    voltage source, VS , equals the voltage load, VL, as shown in the schematic of Figure 12. When impedance is matched, maximum power is transferred...maximum power is 42 transmitted, and VS =VL. The voltage drops shown in Table 7 are from the skin effect at frequencies above 1 MHz, as well... voltage . 46 3.1.6 Response to CVR Location The purpose of these experiments was to find the best cable and connector attachment that would

  12. Resonant Rectifier ICs for Piezoelectric Energy Harvesting Using Low-Voltage Drop Diode Equivalents

    PubMed Central

    Din, Amad Ud; Chandrathna, Seneke Chamith; Lee, Jong-Wook

    2017-01-01

    Herein, we present the design technique of a resonant rectifier for piezoelectric (PE) energy harvesting. We propose two diode equivalents to reduce the voltage drop in the rectifier operation, a minuscule-drop-diode equivalent (MDDE) and a low-drop-diode equivalent (LDDE). The diode equivalents are embedded in resonant rectifier integrated circuits (ICs), which use symmetric bias-flip to reduce the power used for charging and discharging the internal capacitance of a PE transducer. The self-startup function is supported by synchronously generating control pulses for the bias-flip from the PE transducer. Two resonant rectifier ICs, using both MDDE and LDDE, are fabricated in a 0.18 μm CMOS process and their performances are characterized under external and self-power conditions. Under the external-power condition, the rectifier using LDDE delivers an output power POUT of 564 μW and a rectifier output voltage VRECT of 3.36 V with a power transfer efficiency of 68.1%. Under self-power conditions, the rectifier using MDDE delivers a POUT of 288 μW and a VRECT of 2.4 V with a corresponding efficiency of 78.4%. Using the proposed bias-flip technique, the power extraction capability of the proposed rectifier is 5.9 and 3.0 times higher than that of a conventional full-bridge rectifier. PMID:28422085

  13. Resonant Rectifier ICs for Piezoelectric Energy Harvesting Using Low-Voltage Drop Diode Equivalents.

    PubMed

    Din, Amad Ud; Chandrathna, Seneke Chamith; Lee, Jong-Wook

    2017-04-19

    Herein, we present the design technique of a resonant rectifier for piezoelectric (PE) energy harvesting. We propose two diode equivalents to reduce the voltage drop in the rectifier operation, a minuscule-drop-diode equivalent (MDDE) and a low-drop-diode equivalent (LDDE). The diode equivalents are embedded in resonant rectifier integrated circuits (ICs), which use symmetric bias-flip to reduce the power used for charging and discharging the internal capacitance of a PE transducer. The self-startup function is supported by synchronously generating control pulses for the bias-flip from the PE transducer. Two resonant rectifier ICs, using both MDDE and LDDE, are fabricated in a 0.18 μm CMOS process and their performances are characterized under external and self-power conditions. Under the external-power condition, the rectifier using LDDE delivers an output power P OUT of 564 μW and a rectifier output voltage V RECT of 3.36 V with a power transfer efficiency of 68.1%. Under self-power conditions, the rectifier using MDDE delivers a P OUT of 288 μW and a V RECT of 2.4 V with a corresponding efficiency of 78.4%. Using the proposed bias-flip technique, the power extraction capability of the proposed rectifier is 5.9 and 3.0 times higher than that of a conventional full-bridge rectifier.

  14. Lithium battery discharge tests

    NASA Technical Reports Server (NTRS)

    Johnson, C. J.

    1980-01-01

    The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

  15. High voltage MOSFET switching circuit

    DOEpatents

    McEwan, Thomas E.

    1994-01-01

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  16. Contact angle hysteresis and oil film lubrication in electrowetting with two immiscible liquids

    NASA Astrophysics Data System (ADS)

    Gao, J.; Mendel, N.; Dey, R.; Baratian, D.; Mugele, F.

    2018-05-01

    Electrowetting (EW) of water drops in ambient oil has found a wide range of applications including lab-on-a-chip devices, display screens, and variable focus lenses. The efficacy of all these applications is dependent on the contact angle hysteresis (CAH), which is generally reduced in the presence of ambient oil due to thin lubrication layers. While it is well-known that AC voltage reduces the effective contact angle hysteresis (CAH) for EW in ambient air, we demonstrate here that CAH for EW in ambient oil increases with increasing AC and DC voltage. Taking into account the disjoining pressure of the fluoropolymer-oil-water system, short range chemical interactions, viscous oil entrainment, and electrostatic stresses, we find that this observation can be explained by progressive thinning of the oil layer underneath the drop with increasing voltage. This exposes the droplet to the roughness of the underlying solid and thereby increases hysteresis.

  17. The STD/MHD codes - Comparison of analyses with experiments at AEDC/HPDE, Reynolds Metal Co., and Hercules, Inc. [for MHD generator flows

    NASA Technical Reports Server (NTRS)

    Vetter, A. A.; Maxwell, C. D.; Swean, T. F., Jr.; Demetriades, S. T.; Oliver, D. A.; Bangerter, C. D.

    1981-01-01

    Data from sufficiently well-instrumented, short-duration experiments at AEDC/HPDE, Reynolds Metal Co., and Hercules, Inc., are compared to analyses with multidimensional and time-dependent simulations with the STD/MHD computer codes. These analyses reveal detailed features of major transient events, severe loss mechanisms, and anomalous MHD behavior. In particular, these analyses predicted higher-than-design voltage drops, Hall voltage overshoots, and asymmetric voltage drops before the experimental data were available. The predictions obtained with these analyses are in excellent agreement with the experimental data and the failure predictions are consistent with the experiments. The design of large, high-interaction or advanced MHD experiments will require application of sophisticated, detailed and comprehensive computational procedures in order to account for the critical mechanisms which led to the observed behavior in these experiments.

  18. Novel trench gate field stop IGBT with trench shorted anode

    NASA Astrophysics Data System (ADS)

    Xudong, Chen; Jianbing, Cheng; Guobing, Teng; Houdong, Guo

    2016-05-01

    A novel trench field stop (FS) insulated gate bipolar transistor (IGBT) with a trench shorted anode (TSA) is proposed. By introducing a trench shorted anode, the TSA-FS-IGBT can obviously improve the breakdown voltage. As the simulation results show, the breakdown voltage is improved by a factor of 19.5% with a lower leakage current compared with the conventional FS-IGBT. The turn off time of the proposed structure is 50% lower than the conventional one with less than 9% voltage drop increased at a current density of 150 A/cm2. Additionally, there is no snapback observed. As a result, the TSA-FS-IGBT has a better trade-off relationship between the turn off loss and forward drop. Project supported by the National Natural Science Foundation of China (No. 61274080) and the Postdoctoral Science Foundation of China (No. 2013M541585).

  19. Giant magneto-impedance and magneto-inductive effects in amorphous alloys

    NASA Astrophysics Data System (ADS)

    Panina, L. V.; Mohri, K.; Bushida, K.; Noda, M.

    1994-11-01

    Recent experiments have discovered giant and sensitive magneto-impedance and magneto-inductive effects in FeCoSiB amorphous wires. These effects include a sensitive change in an ac wire voltage with the application of a small dc longitudinal magnetic field. At low frequencies (1-10 kHz) the inductive voltage drops by 50% for a field of 2 Oe (25%/Oe) reflecting a strong field dependence of the circumferential permeability. At higher frequencies (0.1-10 MHz) when the skin effect is essential, the amplitude of the total wire voltage decreases by 40%-60% for fields of 3-10 Oe (about 10%/Oe). These effects exhibit no hysteresis for the variation of an applied field and can be obtained even in wires of 1 mm length and a few micrometer diameter. These characteristics are very useful to constitute a highly sensitive microsensor head to detect local fields of the order of 10(exp -5) Oe. In this paper, we review recently obtained experimental results on magneto-inductive and magneto-impedance effects and present a detailed discussion for their mechanism, developing a general approach in terms of ac complex impedance in a magnetic conductor. In the case of a strong skin effect the total wire impedance depends on the circumferential permeability through the penetration depth, resulting in the giant magneto-impedance effect.

  20. High voltage MOSFET switching circuit

    DOEpatents

    McEwan, T.E.

    1994-07-26

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET. 2 figs.

  1. Radiometric and Radiation Response of Visible FPAs

    NASA Technical Reports Server (NTRS)

    Hubbs, John

    2007-01-01

    The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

  2. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE PAGES

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.; ...

    2017-08-18

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  3. Hybrid Ag 2VO 2PO 4/CF x as a High Capacity and Energy Cathode for Primary Batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yue Ru; Bruck, Andrea M.; Brady, Alexander B.

    In this report, we describe the electrochemistry of hybrid dual silver vanadium phosphorus oxide/carbon fluoride (Ag 2VO 2PO 4/CF x) cathodes with various weight ratios. Through modification of the Ag 2VO 2PO 4/CF x ratio, we can control the gravimetric and volumetric capacity, as well as mitigate the voltage drop during high current pulses. The increase in impedance caused by irreversible LiF formation in CFx was reduced by the silver reduction-displacement during electrochemical discharge of the Ag 2VO 2PO 4. Moreover, the addition of graphite was shown to reduce initial voltage delay. When Ag 2VO 2PO 4 dominates the electrodemore » mass (i.e. 75/25 Ag 2VO 2PO 4/CF x) in the hybrid cathode, pulse testing shows less voltage drop and delay, but at the expense of capacity and energy density. As the amount of CFx in the composite increases (i.e. Ag 2VO 2PO 4/CF x ratio of to 50/50 or 25/75), charge capacity and energy density increases, but at the expense of larger voltage drops and delays early in the discharge process. Thus, controlling the Ag 2VO 2PO 4/CF x ratio can be used to tune the electrochemical properties of the dual cathode, allowing for optimization of capacity and power depending on the application.« less

  4. A Fresh Look at the Semiconductor Bandgap Using Constant Current Data

    ERIC Educational Resources Information Center

    Ocaya, R. O.; Luhanga, P. V. C.

    2011-01-01

    It is shown that the well-known linear variation of p-n diode terminal voltage with temperature at different fixed forward currents allows easy and accurate determination of the semiconductor ideality factor and bandgap from only two data points. This is possible if the temperature difference required to maintain the same diode voltage drop can be…

  5. MCT/MOSFET Switch

    NASA Technical Reports Server (NTRS)

    Rippel, Wally E.

    1990-01-01

    Metal-oxide/semiconductor-controlled thyristor (MCT) and metal-oxide/semiconductor field-effect transistor (MOSFET) connected in switching circuit to obtain better performance. Offers high utilization of silicon, low forward voltage drop during "on" period of operating cycle, fast turnon and turnoff, and large turnoff safe operating area. Includes ability to operate at high temperatures, high static blocking voltage, and ease of drive.

  6. Electrohydrodynamic generation of millimetric drops and control of electrification

    NASA Astrophysics Data System (ADS)

    Yun, Sungchan

    2017-07-01

    We report a simple method for millimetric drop generation by electrohydrodynamic (EHD) detachment using a conventional nozzle-ring device. The EHD detachment method provides distinct features of uniform-size and controlled electrification of millimetric drops. The drop dynamics of detachment and shape oscillation are recorded using a high-speed camera and analyzed for several dc voltages applied to the electrode. Experimental studies show that an oscillation frequency can be closely related to the amount of electric charge, which can be explained based on both effective interfacial tension and inviscid Rayleigh and Lamb frequency. Furthermore, we present a concept to generate a neutral drop by adjusting the duration time of a pulse signal and discuss a drop oscillation induced by the detachment. This study can provide potential implications for drop manipulation, such as transporting, merging, and mixing, in microfluidic platforms.

  7. The chording effect on core losses of three-phase induction motor under sinusoidal and PWM voltage supplies

    NASA Astrophysics Data System (ADS)

    Deshmukh, Ram; Moses, A. J.; Anayi, F.

    The core losses and the lower-order voltage harmonics of four different chorded motors fed from sinusoidal supply and inverter voltage supply were invigilated at no-load condition. All the four motors were tested with 4, 8 and 16 kHz switching frequencies and 30, 40, 50 and 60 Hz modulation frequencies The motor with 120° coil pitch has the least core losses and the lower-order voltage harmonics under sinusoidal and pulse width modulation (PWM) voltage supplies at all switching and modulation frequencies. The drop in the core losses for this motor was 46% and 53% under sinusoidal and PWM voltage supplies, respectively. The motor with 120° coil pitch is recommended to be used under sinusoidal and PWM voltage supplies.

  8. Impact of Distribution Feeders that do not have Voltage Regulators on the number of Charged Electric Vehicles using IEEE 34 Bus Test Feeder

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allehyani, Ahmed; Beshir, Mohammed

    Voltage regulators help maintain an acceptable voltage profile for the system. This paper discusses the effect of installing voltage regulators to the system to fix the voltage drop resulting from the electrical vehicles loading increase when they are being charged. The effect will be studied in the afternoon, when the peak load occurs, using the IEEE 34 bus test feeder. First, only one spot node is used to charge the electric vehicles while a voltage regulator is present. Second, five spot nodes are loaded at the same time to charge the electric vehicles while voltage regulators are installed at eachmore » node. After that, the impact of electric vehicles on distribution feeders that do not have voltage regulators will appear.« less

  9. Voltage transfer function as an optical method to characterize electrical properties of liquid crystal devices.

    PubMed

    Bateman, J; Proctor, M; Buchnev, O; Podoliak, N; D'Alessandro, G; Kaczmarek, M

    2014-07-01

    The voltage transfer function is a rapid and visually effective method to determine the electrical response of liquid crystal (LC) systems using optical measurements. This method relies on crosspolarized intensity measurements as a function of the frequency and amplitude of the voltage applied to the device. Coupled with a mathematical model of the device it can be used to determine the device time constants and electrical properties. We validate the method using photorefractive LC cells and determine the main time constants and the voltage dropped across the layers using a simple nonlinear filter model.

  10. Comparison of high speed DI-LIGBT structures

    NASA Astrophysics Data System (ADS)

    Sunkavalli, Ravishankar; Baliga, B. Jayant

    1997-12-01

    The performance of the DI segmented collector (SC)-LIGBT is compared to the collector shorted (CS)-LIGBT. The SC-LIGBT allows for adjusting the tradeoff between switching speed and on-state voltage drop by simply changing the P+ collector segment width during device layout. In contrast to previously reported junction isolated (JI) devices, the DI SC-LIGBT was observed to have a turnoff speed similar to the CS-LIGBT with a higher forward drop than the conventional LIGBT. The on-state performance of the integral diodes of the SC-LIGBTs was found to be superior to the integral diode of the CS-LIGBT. The integral diodes of both the CS and the SC-LIGBTs were found to have much superior switching characteristics compared to a lateral PiN diode at the expense of a higher on-state voltage drop. Thus, the superior switching characteristics of the integral diode in the SC-LIGBT complements its fast switching behavior making this device attractive for compact, high frequency, high efficient, power ICs.

  11. Controlling charge on levitating drops.

    PubMed

    Hilger, Ryan T; Westphall, Michael S; Smith, Lloyd M

    2007-08-01

    Levitation technologies are used in containerless processing of materials, as microscale manipulators and reactors, and in the study of single drops and particles. Presented here is a method for controlling the amount and polarity of charge on a levitating drop. The method uses single-axis acoustic levitation to trap and levitate a single, initially neutral drop with a diameter between 400 microm and 2 mm. This drop is then charged in a controllable manner using discrete packets of charge in the form of charged drops produced by a piezoelectric drop-on-demand dispenser equipped with a charging electrode. The magnitude of the charge on the dispensed drops can be adjusted by varying the voltage applied to the charging electrode. The polarity of the charge on the added drops can be changed allowing removal of charge from the trapped drop (by neutralization) and polarity reversal. The maximum amount of added charge is limited by repulsion of like charges between the drops in the trap. This charging scheme can aid in micromanipulation and the study of charged drops and particles using levitation.

  12. Resistive method for measuring the disintegration speed of Prince Rupert's drops

    NASA Astrophysics Data System (ADS)

    Bochkov, Mark; Gusenkova, Daria; Glushkov, Evgenii; Zotova, Julia; Zhabin, S. N.

    2016-09-01

    We have successfully applied the resistance grid technique to measure the disintegration speed in a special type of glass objects, widely known as Prince Rupert's drops. We use a fast digital oscilloscope and a simple electrical circuit, glued to the surface of the drops, to detect the voltage changes, corresponding to the breaks in the specific parts of the drops. The results obtained using this method are in good qualitative and quantitative agreement with theoretical predictions and previously published data. Moreover, the proposed experimental setup does not include any expensive equipment (such as a high-speed camera) and can therefore be widely used in high schools and universities.

  13. Effect of combined platinum and electron on the temperature dependence of forward voltage in fast recovery diode

    NASA Astrophysics Data System (ADS)

    Jia, Yun-Peng; Zhao, Bao; Yang, Fei; Wu, Yu; Zhou, Xuan; Li, Zhe; Tan, Jian

    2015-12-01

    The temperature dependences of forward voltage drop (VF) of the fast recovery diodes (FRDs) are remarkably influenced by different lifetime controlled treatments. In this paper the results of an experimental study are presented, which are the lifetime controls of platinum treatment, electron irradiation treatment, and the combined treatment of the above ones. Based on deep level transient spectroscopy (DLTS) measurements, a new level E6 (EC-0.376 eV) is found in the combined lifetime treated (CLT) sample, which is different from the levels of the individual platinum and electron irradiation ones. Comparing the tested VF results of CLT samples with the others, the level E6 is responsible for the degradation of temperature dependence of the forward voltage drop in the FRD. Project supported by the Doctoral Fund of Ministry of Education of China (Grant No. 20111103120016) and the State Grid Corporation of China Program of Science and Technology, China (Grant No. 5455DW140003).

  14. On the Mechanism of Maintenance and Instability of the Overvoltage Low-Pressure Discharge Forming a High-Current Runaway Electron Beam

    NASA Astrophysics Data System (ADS)

    Akishev, Yu. S.; Balakirev, A. A.; Karal'nik, V. B.; Medvedev, M. A.; Petryakov, A. V.; Trushkin, N. I.; Shafikov, A. G.

    2017-12-01

    Results of experiments on the study of dynamics of an overvoltage discharge at the low pressure p = 0.5-2.5 Torr up to its transition to the high-current low-voltage regime are presented, and the instability mechanism leading to a sharp voltage drop across the discharge is suggested.

  15. System and method for charging electrochemical cells in series

    DOEpatents

    DeLuca, William H.; Hornstra, Jr, Fred; Gelb, George H.; Berman, Baruch; Moede, Larry W.

    1980-01-01

    A battery charging system capable of equalizing the charge of each individual cell at a selected full charge voltage includes means for regulating charger current to first increase current at a constant rate until a bulk charging level is achieved or until any cell reaches a safe reference voltage. A system controller then begins to decrease the charging rate as long as any cell exceeds the reference voltage until an equalization current level is reached. At this point, the system controller activates a plurality of shunt modules to permit shunting of current around any cell having a voltage exceeding the reference voltage. Leads extending between the battery of cells and shunt modules are time shared to permit alternate shunting of current and voltage monitoring without the voltage drop caused by the shunt current. After each cell has at one time exceeded the reference voltage, the charging current is terminated.

  16. Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

    NASA Technical Reports Server (NTRS)

    Deng, Yi; Jeevarajan, Judith; Rehm, Raymond; Bragg, Bobby; Strangways, Brad

    2002-01-01

    Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

  17. Dynamic Response in Nanoelectrowetting on a Dielectric.

    PubMed

    Choudhuri, Jyoti Roy; Vanzo, Davide; Madden, Paul Anthony; Salanne, Mathieu; Bratko, Dusan; Luzar, Alenka

    2016-09-27

    Droplet spreading at an applied voltage underlies the function of tunable optical devices including adjustable lenses and matrix display elements. Faster response and the enhanced resolution motivate research toward miniaturization of these devices to nanoscale dimensions. The response of an aqueous nanodroplet to an applied field can differ significantly from macroscopic predictions. Understanding these differences requires characterization at the molecular level. We describe the equilibrium and nonequilibrium molecular dynamics simulations of nanosized aqueous droplets on a hydrophobic surface with the embedded concentric electrodes. Constant electrode potential is enforced by a rigorous account of the metal polarization. We demonstrate that the reduction of the equilibrium contact angle is commensurate to, and adjusts reversibly with, the voltage change. For a droplet with O(10) nm diameter, a typical response time to the imposition of the field is of O(10(2)) ps. Drop relaxation is about twice as fast when the field is switched off. The friction coefficient obtained from the rate of the drop relaxation on the nonuniform surface, decreases when the droplet approaches equilibrium from either direction, that is, by spreading or receding. The strong dependence of the friction on the surface hydrophilicity points to the dominance of the liquid-surface friction at the drop's perimeter as described in the molecular kinetic theory. This approach enables correct predictions of trends in dynamic responses associated with varied voltage or substrate material.

  18. Electric current distribution of a multiwall carbon nanotube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Li-Ying; Chang, Chia-Seng, E-mail: jasonc@phys.sinica.edu.tw; Institute of Physics, Academia Sinica, Taipei 11529, Taiwan

    2016-07-15

    The electric current distribution in a multiwall carbon nanotube (MWCNT) was studied by in situ measuring the electric potential along an individual MWCNT in the ultra-high vacuum transmission electron microscope (TEM). The current induced voltage drop along each section of a side-bonded MWCNT was measured by a potentiometric probe in TEM. We have quantitatively derived that the current on the outermost shell depends on the applied current and the shell diameter. More proportion of the total electronic carriers hop into the inner shells when the applied current is increased. The larger a MWCNT’s diameter is, the easier the electronic carriersmore » can hop into the inner shells. We observed that, for an 8 nm MWCNT with 10 μA current applied, 99% of the total current was distributed on the outer two shells.« less

  19. Investigations of the quality of hospital electric power supply and the tolerance of medical electric devices to voltage dips.

    PubMed

    Hanada, Eisuke; Itoga, Shuuya; Takano, Kyoko; Kudou, Takato

    2007-06-01

    Medical devices driven by electric power have come to be commonly used in hospitals, and rapid changes of voltage or current can easily cause them to fail. A stable and high quality power supply is indispensable in order to maintain safety in the modern clinical setting. Therefore, we investigated the quality of the power supply in a hospital and determined the tolerance of 13 pieces of medical equipment to voltage dips. The results showed little distortion of the voltage wave. However, we found an approximately 7% momentary voltage dip caused by lightening and other problems, such as 2 to 5% periodic drops in voltage and voltage wave distortions caused by incorrect grounding. In a tolerance test, the settings of some medical devices were changed at the time of automatic reboot after a disturbance. For another device, trend information was initialized.

  20. Calibration of PVDF Film Transducers for the Cavitation Impact Measurement

    NASA Astrophysics Data System (ADS)

    Hujer, Jan; Müller, Miloš

    2018-06-01

    This paper describes investigation of the influence of the protective layer thickness on the calibration sensitivity of PVDF films sensors for the cavitation impacts measurements. The PVDF film sensor is casted into an aluminium block. The drop ball method is used for the measurement of the relation between impact force and the voltage detected on the PVDF film sensor. The calibration constants are measured for three different protective layers thicknesses. Five different ball weights for 400 mm drop height are used to reach the required impact force range. The ball positions for the evaluation of the impact force are measured with a high speed camera. The voltage signal detected on the PVDF film clamps was measured with a high speed digitizer. The measured signals are analysed in LabVIEW Signal Express.

  1. Project W-320, 241-C-106 sluicing electrical calculations, Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, J.W.

    1998-08-07

    This supporting document has been prepared to make the FDNW calculations for Project W-320, readily retrievable. These calculations are required: To determine the power requirements needed to power electrical heat tracing segments contained within three manufactured insulated tubing assemblies; To verify thermal adequacy of tubing assembly selection by others; To size the heat tracing feeder and branch circuit conductors and conduits; To size protective circuit breaker and fuses; and To accomplish thermal design for two electrical heat tracing segments: One at C-106 tank riser 7 (CCTV) and one at the exhaust hatchway (condensate drain). Contents include: C-Farm electrical heat tracing;more » Cable ampacity, lighting, conduit fill and voltage drop; and Control circuit sizing and voltage drop analysis for the seismic shutdown system.« less

  2. Comment on "Flexible Asymmetric Supercapacitors Based on Nitrogen-Doped Graphene Hydrogels with Embedded Nickel Hydroxide Nanoplates".

    PubMed

    Vongehr, Sascha

    2017-05-22

    It is argued that the main claims of "Flexible Asymmetric Supercapacitors Based on Nitrogen-Doped Graphene Hydrogels with Embedded Nickel Hydroxide Nanoplates" are strongly exaggerated. By selecting first a subregion (ΔV) of the total voltage drop, the capacitance (C ΔV ) is inflated by 30 %. Then, by selecting different regions for different properties and using different ΔV values in different terms of a single expression for the energy density (E ΔV ), the value is doubled. A bending angle of only 45° is instead claimed to be 180°. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Modeling of Gate Bias Modulation in Carbon Nanotube Field-Effect-Transistor

    NASA Technical Reports Server (NTRS)

    Toshishige, Yamada; Biegel, Bryan A. (Technical Monitor)

    2002-01-01

    The threshold voltages of a carbon-nanotube (CNT) field-effect transistor (FET) are studied. The CNT channel is so thin that there is no voltage drop perpendicular to the gate electrode plane, and this makes the device characteristics quite unique. The relation between the voltage and the electrochemical potentials, and the mass action law for electrons and holes are examined in the context of CNTs, and inversion and accumulation threshold voltages (V(sub Ti), and V(sub Ta)) are derived. V(sub Ti) of the CNTFETs has a much stronger doping dependence than that of the metal-oxide- semiconductor FETs, while V(sub Ta) of both devices depends weakly on doping with the same functional form.

  4. CVD facility electrical system captor/dapper study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SINGH, G.

    1999-10-28

    Project W-441, CVD Facility Electrical System CAPTOWDAPPER Study validates Meier's hand calculations. This study includes Load flow, short circuit, voltage drop, protective device coordination, and transient motor starting (TMS) analyses.

  5. Application of the electroosmotic effect for thrust generation

    NASA Astrophysics Data System (ADS)

    Hansen, Thomas Edward

    The present work focuses on demonstrating the capabilities of electroosmotic pumps, (EOP) to generate thrust. An underwater glider was successfully propelled by electroosmosis for the first time published - at 0.85 inches per second. Asymmetric AC voltage pulsing proved to produce higher flow rates then equivalent DC pumps for the same average voltage. Ultra-short pulsing proved 100 nanosecond rise times in EOP are possible, which surpassed published predictions by three orders of magnitude. Theories behind efficiency losses of high power EOP were investigated. Direct measurement of effective voltage at the face of a membrane is the most accurate way to determine voltage drop across the electrolyte of an EOP. Forced convection lowered efficiency of the EOP for low voltages by preventing capacitance charging, but proved to prolong pump life during high power application.

  6. The passive cable properties of hair cell stereocilia and their contribution to somatic capacitance measurements.

    PubMed

    Breneman, Kathryn D; Highstein, Stephen M; Boyle, Richard D; Rabbitt, Richard D

    2009-01-01

    Somatic measurements of whole-cell capacitance are routinely used to understand physiologic events occurring in remote portions of cells. These studies often assume the intracellular space is voltage-clamped. We questioned this assumption in auditory and vestibular hair cells with respect to their stereocilia based on earlier studies showing that neurons, with radial dimensions similar to stereocilia, are not always isopotential under voltage-clamp. To explore this, we modeled the stereocilia as passive cables with transduction channels located at their tips. We found that the input capacitance measured at the soma changes when the transduction channels at the tips of the stereocilia are open compared to when the channels are closed. The maximum capacitance is felt with the transducer closed but will decrease as the transducer opens due to a length-dependent voltage drop along the stereocilium length. This potential drop is proportional to the intracellular resistance and stereocilium tip conductance and can produce a maximum capacitance error on the order of fF for single stereocilia and pF for the bundle.

  7. Non-equilibrium transport in the quantum dot: quench dynamics and non-equilibrium steady state

    NASA Astrophysics Data System (ADS)

    Culver, Adrian; Andrei, Natan

    We calculate the non-equilibrium current driven by a voltage drop across a quantum dot. The system is described by the two lead Anderson model at zero temperature with on-site Coulomb repulsion and non-interacting, linearized leads. We prepare the system in an initial state consisting of a free Fermi sea in each lead with the voltage drop given as the difference between the two Fermi levels. We quench the system by coupling the dot to the leads at t =0 and following the time evolution of the wavefunction. In the long time limit a new type of Bethe Ansatz wavefunction emerges, which satisfies the Lippmann-Schwinger equation with the two Fermi seas serving as the boundary conditions. The solution describes the non-equilibrium steady state of the system. We use this solution to compute the infinite time limit of the expectation value of the current operator at a given voltage, yielding the I-V characteristic. The calculation is non-perturbative and exact. Research supported by NSF Grant DMR 1410583.

  8. Non-equilibrium transport in the quantum dot: quench dynamics and non-equilibrium steady state

    NASA Astrophysics Data System (ADS)

    Culver, Adrian; Andrei, Natan

    We present an exact method of calculating the non-equilibrium current driven by a voltage drop across a quantum dot. The system is described by the two lead Anderson model at zero temperature with on-site Coulomb repulsion and non-interacting, linearized leads. We prepare the system in an initial state consisting of a free Fermi sea in each lead with the voltage drop given as the difference between the two Fermi levels. We quench the system by coupling the dot to the leads at t = 0 and following the time evolution of the wavefunction. In the long time limit a new type of Bethe Ansatz wavefunction emerges, which satisfies the Lippmann-Schwinger equation with the two Fermi seas serving as the boundary conditions. This exact, non-perturbative solution describes the non-equilibrium steady state of the system. We describe how to use this solution to compute the infinite time limit of the expectation value of the current operator at a given voltage, which would yield the I-V characteristic of the dot. Research supported by NSF Grant DMR 1410583.

  9. The Effect of Plug-in Electric Vehicles on Harmonic Analysis of Smart Grid

    NASA Astrophysics Data System (ADS)

    Heidarian, T.; Joorabian, M.; Reza, A.

    2015-12-01

    In this paper, the effect of plug-in electric vehicles is studied on the smart distribution system with a standard IEEE 30-bus network. At first, harmonic power flow analysis is performed by Newton-Raphson method and by considering distorted substation voltage. Afterward, proper sizes of capacitors is selected by cuckoo optimization algorithm to reduce the power losses and cost and by imposing acceptable limit for total harmonic distortion and RMS voltages. It is proposed that the impact of generated current harmonics by electric vehicle battery chargers should be factored into overall load control strategies of smart appliances. This study is generalized to the different hours of a day by using daily load curve, and then optimum time for charging of electric vehicles batteries in the parking lots are determined by cuckoo optimization algorithm. The results show that injecting harmonic currents of plug-in electric vehicles causes a drop in the voltage profile and increases power loss. Moreover, charging the vehicle batteries has more impact on increasing the power losses rather than the harmonic currents effect. Also, the findings showed that the current harmonics has a great influence on increasing of THD. Finally, optimum working times of all parking lots was obtained for the utilization cost reduction.

  10. Power characteristics in GMAW: Experimental and numerical investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joensson, P.G.; Szekely, J.; Madigan, R.B.

    1995-03-01

    The voltage and power distributions in gas metal arc welding (GMAW) were studied both experimentally and numerically. The principal voltage drop takes place in the arc, which also constitutes the dominant power contribution. Within the arc, the dominating voltage contributions are from the arc column and the cathode fall, while the anode fall and the electrode regions are less significant. The power input to the arc column increases with both increasing current and increasing arc length. These results indicate that it is critical to control the arc length in order to control the power input to the system.

  11. Dynamic magnetoelectric effect in ferromagnet/superconductor tunnel junctions.

    PubMed

    Trif, Mircea; Tserkovnyak, Yaroslav

    2013-08-23

    We study the magnetization dynamics in a ferromagnet/insulator/superconductor tunnel junction and the associated buildup of the electrical polarization. We show that for an open circuit, the induced voltage varies strongly and nonmonotonically with the precessional frequency, and can be enhanced significantly by the superconducting correlations. For frequencies much smaller or much larger than the superconducting gap, the voltage drops to zero, while when these two energy scales are comparable, the voltage is peaked at a value determined by the driving frequency. We comment on the potential utilization of the effect for the low-temperature spatially resolved spectroscopy of magnetic dynamics.

  12. CONDENSED MATTER: ELECTRONIC STRUCTURE, ELECTRICAL, MAGNETIC, AND OPTICAL PROPERTIES: A super junction SiGe low-loss fast switching power diode

    NASA Astrophysics Data System (ADS)

    Ma, Li; Gao, Yong

    2009-01-01

    This paper proposes a novel super junction (SJ) SiGe switching power diode which has a columnar structure of alternating p- and n- doped pillar substituting conventional n- base region and has far thinner strained SiGe p+ layer to overcome the drawbacks of existing Si switching power diode. The SJ SiGe diode can achieve low specific on-resistance, high breakdown voltages and fast switching speed. The results indicate that the forward voltage drop of SJ SiGe diode is much lower than that of conventional Si power diode when the operating current densities do not exceed 1000 A/cm2, which is very good for getting lower operating loss. The forward voltage drop of the Si diode is 0.66 V whereas that of the SJ SiGe diode is only 0.52 V at operating current density of 10 A/cm2. The breakdown voltages are 203 V for the former and 235 V for the latter. Compared with the conventional Si power diode, the reverse recovery time of SJ SiGe diode with 20 per cent Ge content is shortened by above a half and the peak reverse current is reduced by over 15%. The SJ SiGe diode can remarkably improve the characteristics of power diode by combining the merits of both SJ structure and SiGe material.

  13. Ultralow-voltage-drop GaN/InGaN/GaN tunnel junctions with 12% indium content

    NASA Astrophysics Data System (ADS)

    Akyol, Fatih; Zhang, Yuewei; Krishnamoorthy, Sriram; Rajan, Siddharth

    2017-12-01

    We report a combination of highly doped layers and polarization engineering that achieves highly efficient blue-transparent GaN/InGaN/GaN tunnel junctions (In content = 12%). NPN diode structures with a low voltage drop of 4.04 V at 5 kA/cm2 and a differential resistance of 6.51 × 10-5 Ω·cm2 at 3 kA/cm2 were obtained. The tunnel junction design with n++-GaN (Si: 5 × 1020 cm-3)/3 nm p++-In0.12Ga0.88N (Mg: 1.5 × 1020 cm-3)/p++-GaN (Mg: 5 × 1020 cm-3) showed the best device performance. Device simulations agree well with the experimentally determined optimal design. The combination of low In composition and high doping can facilitate lower tunneling resistance for blue-transparent light-emitting diodes.

  14. Nanoscale electron transport at the surface of a topological insulator.

    PubMed

    Bauer, Sebastian; Bobisch, Christian A

    2016-04-21

    The use of three-dimensional topological insulators for disruptive technologies critically depends on the dissipationless transport of electrons at the surface, because of the suppression of backscattering at defects. However, in real devices, defects are unavoidable and scattering at angles other than 180° is allowed for such materials. Until now, this has been studied indirectly by bulk measurements and by the analysis of the local density of states in close vicinity to defect sites. Here, we directly measure the nanoscale voltage drop caused by the scattering at step edges, which occurs if a lateral current flows along a three-dimensional topological insulator. The experiments were performed using scanning tunnelling potentiometry for thin Bi2Se3 films. So far, the observed voltage drops are small because of large contributions of the bulk to the electronic transport. However, for the use of ideal topological insulating thin films in devices, these contributions would play a significant role.

  15. Nanoscale electron transport at the surface of a topological insulator

    NASA Astrophysics Data System (ADS)

    Bauer, Sebastian; Bobisch, Christian A.

    2016-04-01

    The use of three-dimensional topological insulators for disruptive technologies critically depends on the dissipationless transport of electrons at the surface, because of the suppression of backscattering at defects. However, in real devices, defects are unavoidable and scattering at angles other than 180° is allowed for such materials. Until now, this has been studied indirectly by bulk measurements and by the analysis of the local density of states in close vicinity to defect sites. Here, we directly measure the nanoscale voltage drop caused by the scattering at step edges, which occurs if a lateral current flows along a three-dimensional topological insulator. The experiments were performed using scanning tunnelling potentiometry for thin Bi2Se3 films. So far, the observed voltage drops are small because of large contributions of the bulk to the electronic transport. However, for the use of ideal topological insulating thin films in devices, these contributions would play a significant role.

  16. Harvesting energy from low-frequency excitations through alternate contacts between water and two dielectric materials.

    PubMed

    Yu, Jian; Ma, Enze; Ma, Tianwei

    2017-12-07

    Recent studies have demonstrated the benefits of water-dielectric interfaces in electrostatic energy harvesting. Most efforts have been focused on extracting the kinetic energy from the motions of water drops on hydrophobic surfaces, and thus, the resulting schemes inherently prefer cases where the water drops move at a high speed, or vibrate at a high frequency. Here we report a method for directly harvesting ambient mechanical energy as electric potential energy through water droplets by making alternate contacts with CYTOP and PTFE thin films. Because CYTOP and PTFE acquire significantly different surface charge densities during contact with water, such a difference can be utilized to effectively generate electricity. We demonstrate this concept using prototype devices fabricated on silicon substrates with a simple procedure. In the experiments conducted, a water drop of 400 μL alone could generate a peak open-circuit voltage of 42 V under a 0.25 Hz vibration. Under a 2.5 Hz vibration, the peak open-circuit voltage reached 115 V under an external bias of 8 V. The demonstrated efficiency is orders of magnitude higher than those of existing devices of similar dimensions.

  17. Focal length hysteresis of a double-liquid lens based on electrowetting

    NASA Astrophysics Data System (ADS)

    Peng, Runling; Wang, Dazhen; Hu, Zhiwei; Chen, Jiabi; Zhuang, Songlin

    2013-02-01

    In this paper, an extended Young equation especially suited for an ideal cylindrical double-liquid variable-focus lens is derived by means of an energy minimization method. Based on the extended Young equation, a kind of focal length hysteresis effect is introduced into the double-liquid variable-focus lens. Such an effect can be explained theoretically by adding a force of friction to the tri-phase contact line. Theoretical analysis shows that the focal length at a particular voltage can be different depending on whether the applied voltage is increasing or decreasing, that is, there is a focal length hysteresis effect. Moreover, the focal length at a particular voltage must be larger when the voltage is rising than when it is dropping. These conclusions are also verified by experiments.

  18. A high-efficiency low-voltage CMOS rectifier for harvesting energy in implantable devices.

    PubMed

    Hashemi, S Saeid; Sawan, Mohamad; Savaria, Yvon

    2012-08-01

    We present, in this paper, a new full-wave CMOS rectifier dedicated for wirelessly-powered low-voltage biomedical implants. It uses bootstrapped capacitors to reduce the effective threshold voltage of selected MOS switches. It achieves a significant increase in its overall power efficiency and low voltage-drop. Therefore, the rectifier is good for applications with low-voltage power supplies and large load current. The rectifier topology does not require complex circuit design. The highest voltages available in the circuit are used to drive the gates of selected transistors in order to reduce leakage current and to lower their channel on-resistance, while having high transconductance. The proposed rectifier was fabricated using the standard TSMC 0.18 μm CMOS process. When connected to a sinusoidal source of 3.3 V peak amplitude, it allows improving the overall power efficiency by 11% compared to the best recently published results given by a gate cross-coupled-based structure.

  19. 11.72 sq cm SiC Wafer-scale Interconnected 64 kA PiN Diode

    DTIC Science & Technology

    2012-01-30

    drop of 10.3 V. The dissipated energy was 382 J and the calculated action exceeded 1.7 MA2 -s. Preliminary development of high voltage interconnection...scale diode action (surge current integral), a key reliability parameter, exceeded 1.7 MA2 -s. Figure 6: The wafer-scale interconnected diode...scale diode was 382 J and the calculated action exceeded 1.7 MA2 -sec. High voltage operation of PiN diodes, thyristors, and other semiconductor

  20. Efficiency and weight of voltage multiplier type ultra lightweight dc-dc converters

    NASA Technical Reports Server (NTRS)

    Harrigill, W. T., Jr.; Myers, I. T.

    1975-01-01

    An analytical and experimental study was made of a capacitor-diode voltage multiplier without a transformer which offers the possibility of high efficiency with light weight. The dc-dc conversion efficiencies of about 94 percent were achieved at output powers of 150 watts at 1000 volts using 8x multiplication. A detailed identification of losses was made, including forward drop losses in component, switching losses, reverse junction capacitance charging losses, and charging losses in the main ladder capacitors.

  1. Modelling and analysis of piezoelectric cantilever energy harvester for different proof mass and material proportion

    NASA Astrophysics Data System (ADS)

    Shashank, R.; Harisha, S. K., Dr; Abhishek, M. C.

    2018-02-01

    Energy harvesting using ambient energy sources is one of the fast growing trends in the world, research and development in the area of energy harvesting is moving progressively to get maximum power output from the existing resources. The ambient sources of energy available in the nature are solar energy, wind energy, thermal energy, vibrational energy etc. out of these methods energy harvesting by vibrational energy sources gain more importance due to its nature of not getting influenced by any environmental parameters and its free availability at anytime and anywhere. The project mainly deals with validating the values of voltage and electrical power output of experimentally conducted energy harvester, varying the parameters of the energy harvester and analyse the effect of the parameters on the performance of the energy harvester and compare the results. The cantilever beam was designed, analysed and simulated using COMSOL multi-physics software. The energy harvester gives an electrical output voltage of the 2.75 volts at a natural frequency of 37.2 Hz and an electrical power of 29μW. Decreasing the percentage of the piezoelectric material and simultaneously increasing the percentage of polymer material (so that total percentage of proportion remains same) increases the electrical voltage and decreases the natural frequency of the beam linearly upto 3.9V and 28.847 Hz till the percentage proportion of the beam was 24% piezoelectric beam and 76% polymer beam when the percentage proportion increased to 26% and 74% natural frequency goes on decreases further but voltage suddenly drops to 2.8V. The voltage generated by energy harvester increases proportionally and reaches 3.7V until weight of the proof mass reaches 4 grams and further increase in the weight of the proof mass decreases the voltage generated by energy harvester. Thus the investigation conveys that the weight of the proof mass and the length of the cantilever beam should be optimised to obtain maximum output efficiency of energy harvester.

  2. Numerical investigation on the dynamics and evolution mechanisms of multiple-current-pulse behavior in homogeneous helium dielectric-barrier discharges at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Zhang, Yuhui; Ning, Wenjun; Dai, Dong

    2018-03-01

    A systematic investigation on the dynamics and evolution mechanisms of multiple-current-pulse (MCP) behavior in homogeneous dielectric barrier discharge (HDBD) is carried out via fluid modelling. Inspecting the simulation results, two typical discharge regimes, namely the MCP-Townsend regime and MCP-glow regime, are found prevailing in MCP discharges, each with distinctive electrical and dynamic properties. Moreover, the evolution of MCP behavior with external parameters altering are illustrated and explicitly discussed. It is revealed that the discharge undergoes some different stages as external parameters vary, and the discharge in each stage follows a series of distinctive pattern in morphological characteristics and evolution trends. Among those stages, the pulse number per half cycle is perceived to observe non-monotonic variations with applied voltage amplitude (Vam) and gap width (dg) increasing, and a merging effect among pulses, mainly induced by the enhanced contribution of sinusoidal component to the total current, is considered responsible for such phenomenon. The variation of incipient discharge peak phase (Φpm) is dominated by the value of Vam as well as the proportion of total applied voltage that drops across the gas gap. Moreover, an abnormal, dramatic elevation in Jpm with dg increasing is observed, which could be evinced by the strengthened glow discharge structure and therefore enhanced space charge effect.

  3. Heat radiation approach for harnessing heat of the cook stove to generate electricity for lighting system and charging of mobile phone

    NASA Astrophysics Data System (ADS)

    Muñoz, Rodrigo C., Jr.; Manansala, Chad Deo G.

    2018-01-01

    This study is based on the potential of thermoelectric coupling such as the thermoelectric cooler module. A thermoelectric cooler converts the heat coming from the cook stove into electricity and store in a battery. A dc-dc boost converter will be used to produce enough voltage to light a minimum house dwelling or charge phone battery. This device will be helpful to those that faces a problem on electricity especially in the isolated areas. The study aims (1) to harness heat from the cook stove up to 110 °C (2) To automatically cool-off the system to protect the thermoelectric cooler from damage due to excessive heat using an electronic solenoid; (3) To store energy harnessed in the battery; (4) To amplify the output voltages of the battery using DC to DC boost converter for lighting system and charging of mobile phone battery. From various tests conducted, it can fully charge a mobile phone in 3 hours observing the unit’s battery voltage drop from 4.06V to 3.98V. In the testing it used different orientation of steel rod by conduction to transfer heat and by radiation through tubular steel with its different dimensions. Most recent testing proved that the 2x2x9 tubular steel by radiation had the best result. The temperature reached more than a hundred degree Celsius that met the objective. The test resulted of boosting the voltage of the battery output from 3.7V to 4.96V on the average. The boosted voltage decrease as the system’s cool-off mechanism operated when the temperature reached above 110 degree Celsius decreasing output voltage to 0.8V resulting the boosted voltage to drop to zero. Therefore, the proponents concluded that heat waste can be converted to electrical energy by harnessing heat through radiation, with the help of TEC that generates voltage for lighting and can be boosted to be used for mobile charging. Furthermore, the study proved that the excess heat can damaged the TEC which was prevented by using of cooling-off mechanism, making it more useful for longer time.

  4. Containerless protein crystal growth technology: Electrostatic multidrop positioner

    NASA Technical Reports Server (NTRS)

    Rhim, Won-Kyu

    1990-01-01

    A brief discussion of containerless protein crystal growth in space and a diagram of the electrostatic multidrop positioner are presented. A picture of lysome crystals growing in a drop and a graph of levitation voltage versus time (minutes) are also presented.

  5. An 11 cm long atmospheric pressure cold plasma plume for applications of plasma medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Xinpei; Jiang Zhonghe; Xiong Qing

    2008-02-25

    In this letter, a room temperature atmospheric pressure plasma jet device is reported. The high voltage electrode of the device is covered by a quartz tube with one end closed. The device, which is driven by a kilohertz ac power supply, is capable of generating a plasma plume up to 11 cm long in the surrounding room air. The rotational and vibrational temperatures of the plasma plume are 300 and 2300 K, respectively. A simple electrical model shows that, when the plasma plume is contacted with a human, the voltage drop on the human is less than 66 V formore » applied voltage of 5 kV (rms)« less

  6. Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

    NASA Technical Reports Server (NTRS)

    Bever, R. S.

    1975-01-01

    Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

  7. Intelligent energy harvesting scheme for microbial fuel cells: Maximum power point tracking and voltage overshoot avoidance

    NASA Astrophysics Data System (ADS)

    Alaraj, Muhannad; Radenkovic, Miloje; Park, Jae-Do

    2017-02-01

    Microbial fuel cells (MFCs) are renewable and sustainable energy sources that can be used for various applications. The MFC output power depends on its biochemical conditions as well as the terminal operating points in terms of output voltage and current. There exists one operating point that gives the maximum possible power from the MFC, maximum power point (MPP), for a given operating condition. However, this MPP may vary and needs to be tracked in order to maintain the maximum power extraction from the MFC. Furthermore, MFC reactors often develop voltage overshoots that cause drastic drops in the terminal voltage, current, and the output power. When the voltage overshoot happens, an additional control measure is necessary as conventional MPPT algorithms will fail because of the change in the voltage-current relationship. In this paper, the extremum seeking (ES) algorithm was used to track the varying MPP and a voltage overshoot avoidance (VOA) algorithm is developed to manage the voltage overshoot conditions. The proposed ES-MPPT with VOA algorithm was able to extract 197.2 mJ during 10-min operation avoiding voltage overshoot, while the ES MPPT-only scheme stopped harvesting after only 18.75 mJ because of the voltage overshoot happened at 0.4 min.

  8. Allocation of Load-Loss Cost Caused by Voltage Sag

    NASA Astrophysics Data System (ADS)

    Gao, X.

    2017-10-01

    This paper focuses on the allocation of load-loss cost caused by voltage sag in the environment of electricity market. To compensate the loss of loads due to voltage sags, the load-loss cost is allocated to both sources and power consumers. On the basis of Load Drop Cost (LDC), a quantitative evaluation index of load-loss cost caused by voltage sag is identified. The load-loss cost to be allocated to power consumers themselves is calculated according to load classification. Based on the theory of power component the quantitative relation between sources and loads is established, thereby a quantitative calculation method for load-loss cost allocated to each source is deduced and the quantitative compensation from individual source to load is proposed. A simple five-bus system illustrates the main features of the proposed method.

  9. A Wide Area Bipolar Cascade Resonant Cavity Light Emitting Diode for a Hybrid Range-Intensity Sensor

    DTIC Science & Technology

    2008-06-19

    forward bias voltage and a small amount of current flow- ing due to a forward biased tunnel current. (d) shows a drop in the forward bias current due...flowing due to a forward biased tunnel current. (d) shows a drop in the forward bias current due to the widening of the forbidden band, and fewer...3-14 xii Figure Page 3.10. Energy bands of a tunnel junction at various bias levels. (a) shows the junction under reverse bias with holes in

  10. Numerical investigation and thermodynamic analysis of the effect of electrolyte flow rate on performance of all vanadium redox flow batteries

    NASA Astrophysics Data System (ADS)

    Khazaeli, Ali; Vatani, Ali; Tahouni, Nassim; Panjeshahi, Mohammad Hassan

    2015-10-01

    In flow batteries, electrolyte flow rate plays a crucial role on the minimizing mass transfer polarization which is at the compensation of higher pressure drop. In this work, a two-dimensional numerical method is applied to investigate the effect of electrolyte flow rate on cell voltage, maximum depth of discharge and pressure drop a six-cell stack of VRFB. The results show that during the discharge process, increasing electrolyte flow rate can raise the voltage of each cell up to 50 mV on average. Moreover, the maximum depth of discharge dramatically increases with electrolyte flow rate. On the other hand, the pressure drop also positively correlates with electrolyte flow rate. In order to investigate all these effects simultaneously, average energy and exergy efficiencies are introduced in this study for the transient process of VRFB. These efficiencies give insight into choosing an appropriate strategy for the electrolyte flow rate. Finally, the energy efficiency of electricity storage using VRFB is investigated and compared with other energy storage systems. The results illustrate that this kind of battery has at least 61% storage efficiency based on the second law of thermodynamics, which is considerably higher than that of their counterparts.

  11. Radiative Ignition and the Transition to Flame Spread Investigated in the Japan Microgravity Center's 10-sec Drop Shaft

    NASA Technical Reports Server (NTRS)

    1996-01-01

    The Radiative Ignition and Transition to Spread Investigation (RITSI) is a shuttle middeck Glovebox combustion experiment developed by the NASA Lewis Research Center, the National Institute for Standards and Technology (NIST), and Aerospace Design and Fabrication (ADF). It is scheduled to fly on the third United States Microgravity Payload (USMP-3) mission in February 1996. The objective of RITSI is to experimentally study radiative ignition and the subsequent transition to flame spread in low gravity in the presence of very low speed air flows in two- and three-dimensional configurations. Toward this objective, a unique collaboration between NASA, NIST, and the University of Hokkaido was established to conduct 15 science and engineering tests in Japan's 10-sec drop shaft. For these tests, the RITSI engineering hardware was mounted in a sealed chamber with a variable oxygen atmosphere. Ashless filter paper was ignited during each drop by a tungsten-halogen heat lamp focused on a small spot in the center of the paper. The flame spread outward from that point. Data recorded included fan voltage (a measure of air flow), radiant heater voltage (a measure of radiative ignition energy), and surface temperatures (measured by up to three surface thermocouples) during ignition and flame spread.

  12. Mixed Cassie-Baxter wetting states on a porous material stabilized by electrowetting

    NASA Astrophysics Data System (ADS)

    Lambert, Jérôme; Gauchet, Lucien; Crassous, Jérôme

    2017-07-01

    Electrowetting is used to force imbibition in model porous plates. These porous plates are sintered disordered bronze bead packings that are homogeneously coated with a constant-thickness layer of parylene. Cycles of increasing and decreasing voltage trigger the imbibition of a ionized water sessile drop by changing its contact angle with the porous material from non-wetting to wetting shapes. During a cycle, a drop experiences partial imbibition and a strong hysteresis of its contact angle with the porous plate. Since the imbibition process quickly stabilizes, we adopt an equilibrium description of the wetting properties of the drop on the porous plate. Our model, based on the Cassie-Baxter approach, shows that three different wetting states are experienced by the drop, one of which being made possible only by the modification of the contact angle inside the pores. Our model describes the experimental results very well.

  13. Measurement of inkjet first-drop behavior using a high-speed camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Kye-Si, E-mail: kskwon@sch.ac.kr; Kim, Hyung-Seok; Choi, Moohyun

    2016-03-15

    Drop-on-demand inkjet printing has been used as a manufacturing tool for printed electronics, and it has several advantages since a droplet of an exact amount can be deposited on an exact location. Such technology requires positioning the inkjet head on the printing location without jetting, so a jetting pause (non-jetting) idle time is required. Nevertheless, the behavior of the first few drops after the non-jetting pause time is well known to be possibly different from that which occurs in the steady state. The abnormal behavior of the first few drops may result in serious problems regarding printing quality. Therefore, amore » proper evaluation of a first-droplet failure has become important for the inkjet industry. To this end, in this study, we propose the use of a high-speed camera to evaluate first-drop dissimilarity. For this purpose, the image acquisition frame rate was determined to be an integer multiple of the jetting frequency, and in this manner, we can directly compare the droplet locations of each drop in order to characterize the first-drop behavior. Finally, we evaluate the effect of a sub-driving voltage during the non-jetting pause time to effectively suppress the first-drop dissimilarity.« less

  14. Effect of Reduced Tube Voltage on Diagnostic Accuracy of CT Colonography.

    PubMed

    Futamata, Yoshihiro; Koide, Tomoaki; Ihara, Riku

    2017-01-01

    The normal tube voltage in computed tomography colonography (CTC) is 120 kV. Some reports indicate that the use of a low tube voltage (lower than 120 kV) technique plays a significant role in reduction of radiation dose. However, to determine whether a lower tube voltage can reduce radiation dose without compromising diagnostic accuracy, an evaluation of images that are obtained while maintaining the volume CT dose index (CTDI vol ) is required. This study investigated the effect of reduced tube voltage in CTC, without modifying radiation dose (i.e. constant CTDI vol ), on image quality. Evaluation of image quality involved the shape of the noise power spectrum, surface profiling with volume rendering (VR), and receiver operating characteristic (ROC) analysis. The shape of the noise power spectrum obtained with a tube voltage of 80 kV and 100 kV was not similar to the one produced with a tube voltage of 120 kV. Moreover, a higher standard deviation was observed on volume-rendered images that were generated using the reduced tube voltages. In addition, ROC analysis revealed a statistically significant drop in diagnostic accuracy with reduced tube voltage, revealing that the modification of tube voltage affects volume-rendered images. The results of this study suggest that reduction of tube voltage in CTC, so as to reduce radiation dose, affects image quality and diagnostic accuracy.

  15. Electron transport in stepped Bi2Se3 thin films

    NASA Astrophysics Data System (ADS)

    Bauer, S.; Bobisch, C. A.

    2017-08-01

    We analyse the electron transport in a 16 quintuple layer thick stepped Bi2Se3 film grown on Si(1 1 1) by means of scanning tunnelling potentiometry (STP) and multi-point probe measurements. Scanning tunnelling microscopy images reveal that the local structure of the Bi2Se3 film is dominated by terrace steps and domain boundaries. From a microscopic study on the nm scale by STP, we find a mostly linear gradient of the voltage on the Bi2Se3 terraces which is interrupted by voltage drops at the position of the domain boundaries. The voltage drops indicate that the domain boundaries are scatterers for the electron transport. Macroscopic resistance measurements (2PP and in-line 4PP measurement) on the µm scale support the microscopic results. An additional rotational square 4PP measurement shows an electrical anisotropy of the sheet conductance parallel and perpendicular to the Bi2Se3 steps of about 10%. This is a result of the anisotropic step distribution at the stepped Bi2Se3 surface while domain boundaries are distributed isotropically. The determined value of the conductivity of the Bi2Se3 steps of about 1000 S cm-1 verifies the value of an earlier STP study.

  16. The influence of mass configurations on velocity amplified vibrational energy harvesters

    NASA Astrophysics Data System (ADS)

    O'Donoghue, D.; Frizzell, R.; Kelly, G.; Nolan, K.; Punch, J.

    2016-05-01

    Vibrational energy harvesters scavenge ambient vibrational energy, offering an alternative to batteries for the autonomous operation of low power electronics. Velocity amplified electromagnetic generators (VAEGs) utilize the velocity amplification effect to increase power output and operational bandwidth, compared to linear resonators. A detailed experimental analysis of the influence of mass ratio and number of degrees-of-freedom (dofs) on the dynamic behaviour and power output of a macro-scale VAEG is presented. Various mass configurations are tested under drop-test and sinusoidal forced excitation, and the system performances are compared. For the drop-test, increasing mass ratio and number of dofs increases velocity amplification. Under forced excitation, the impacts between the masses are more complex, inducing greater energy losses. This results in the 2-dof systems achieving the highest velocities and, hence, highest output voltages. With fixed transducer size, higher mass ratios achieve higher voltage output due to the superior velocity amplification. Changing the magnet size to a fixed percentage of the final mass showed the increase in velocity of the systems with higher mass ratios is not significant enough to overcome the reduction in transducer size. Consequently, the 3:1 mass ratio systems achieved the highest output voltage. These findings are significant for the design of future reduced-scale VAEGs.

  17. Comparison analysis on the thermal runaway of lithium-ion battery under two heating modes.

    PubMed

    Wu, Tangqin; Chen, Haodong; Wang, Qingsong; Sun, Jinhua

    2018-02-15

    The thermal stability evaluation of materials in a soft-pack commercial cell is tested using C80 calorimeter, including anode, cathode, separator and full cell (mixing of the three materials including additional electrolyte). Thermal runaway characteristic of the commercial cell is tested on the accelerating rate calorimeter (ARC) with two heating modes, including internal heating mode and external heating mode. The results show that the thermal stability of internal material for tested cell follows the below order: anode

  18. Single Crystal Diamond Needle as Point Electron Source.

    PubMed

    Kleshch, Victor I; Purcell, Stephen T; Obraztsov, Alexander N

    2016-10-12

    Diamond has been considered to be one of the most attractive materials for cold-cathode applications during past two decades. However, its real application is hampered by the necessity to provide appropriate amount and transport of electrons to emitter surface which is usually achieved by using nanometer size or highly defective crystallites having much lower physical characteristics than the ideal diamond. Here, for the first time the use of single crystal diamond emitter with high aspect ratio as a point electron source is reported. Single crystal diamond needles were obtained by selective oxidation of polycrystalline diamond films produced by plasma enhanced chemical vapor deposition. Field emission currents and total electron energy distributions were measured for individual diamond needles as functions of extraction voltage and temperature. The needles demonstrate current saturation phenomenon and sensitivity of emission to temperature. The analysis of the voltage drops measured via electron energy analyzer shows that the conduction is provided by the surface of the diamond needles and is governed by Poole-Frenkel transport mechanism with characteristic trap energy of 0.2-0.3 eV. The temperature-sensitive FE characteristics of the diamond needles are of great interest for production of the point electron beam sources and sensors for vacuum electronics.

  19. Single Crystal Diamond Needle as Point Electron Source

    NASA Astrophysics Data System (ADS)

    Kleshch, Victor I.; Purcell, Stephen T.; Obraztsov, Alexander N.

    2016-10-01

    Diamond has been considered to be one of the most attractive materials for cold-cathode applications during past two decades. However, its real application is hampered by the necessity to provide appropriate amount and transport of electrons to emitter surface which is usually achieved by using nanometer size or highly defective crystallites having much lower physical characteristics than the ideal diamond. Here, for the first time the use of single crystal diamond emitter with high aspect ratio as a point electron source is reported. Single crystal diamond needles were obtained by selective oxidation of polycrystalline diamond films produced by plasma enhanced chemical vapor deposition. Field emission currents and total electron energy distributions were measured for individual diamond needles as functions of extraction voltage and temperature. The needles demonstrate current saturation phenomenon and sensitivity of emission to temperature. The analysis of the voltage drops measured via electron energy analyzer shows that the conduction is provided by the surface of the diamond needles and is governed by Poole-Frenkel transport mechanism with characteristic trap energy of 0.2-0.3 eV. The temperature-sensitive FE characteristics of the diamond needles are of great interest for production of the point electron beam sources and sensors for vacuum electronics.

  20. Real time determination of the laser ablated mass by means of electric field-perturbation measurement

    NASA Astrophysics Data System (ADS)

    Pacheco, P.; Álvarez, J.; Sarmiento, R.; Bredice, F.; Sánchez-Aké, C.; Villagrán-Muniz, M.; Palleschi, V.

    2018-04-01

    A Nd:YAG ns-pulsed laser was used to ablate Al, Cd and Zn targets, which were placed between the plates of a planar charged capacitor. The plasma generates a transient redistribution of the electrical charges on the plates that can be measured as a voltage drop across a resistor connected to the ground plate. This signal is proportional to the capacitor applied voltage, the distance between the plates and the total number of ions produced in the ablation process which in turn is related to the laser energy and the ablated mass. After a series of pulses, the targets were weighed on a thermogravimetric balance to measure the ablated mass. Our results show that the electrical signal measured on the resistor is univocally related to the ablated mass from the target. Therefore, after a proper calibration depending on the material and the experimental geometry, the electrical signal can be used for real time quantitative measurement of the ablated mass in pulsed laser generated plasma experiments. The experiments were repeated on an aluminum target, with and without the presence of the external electric field in order to determine the possible influence of the applied electric field on the ablated mass.

  1. Application of active electrode compensation to perform continuous voltage-clamp recordings with sharp microelectrodes.

    PubMed

    Gómez-González, J F; Destexhe, A; Bal, T

    2014-10-01

    Electrophysiological recordings of single neurons in brain tissues are very common in neuroscience. Glass microelectrodes filled with an electrolyte are used to impale the cell membrane in order to record the membrane potential or to inject current. Their high resistance induces a high voltage drop when passing current and it is essential to correct the voltage measurements. In particular, for voltage clamping, the traditional alternatives are two-electrode voltage-clamp technique or discontinuous single electrode voltage-clamp (dSEVC). Nevertheless, it is generally difficult to impale two electrodes in a same neuron and the switching frequency is limited to low frequencies in the case of dSEVC. We present a novel fully computer-implemented alternative to perform continuous voltage-clamp recordings with a single sharp-electrode. To reach such voltage-clamp recordings, we combine an active electrode compensation algorithm (AEC) with a digital controller (AECVC). We applied two types of control-systems: a linear controller (proportional plus integrative controller) and a model-based controller (optimal control). We compared the performance of the two methods to dSEVC using a dynamic model cell and experiments in brain slices. The AECVC method provides an entirely digital method to perform continuous recording and smooth switching between voltage-clamp, current clamp or dynamic-clamp configurations without introducing artifacts.

  2. An alternating voltage battery with two salt-water oscillators

    NASA Astrophysics Data System (ADS)

    Cervellati, Rinaldo; Soldà, Roberto

    2001-05-01

    We built a simple alternating voltage battery that periodically reverses value and sign of its electromotive force (emf). This battery consists of two coupled concentration salt-water oscillators that are phase shifted by initially extracting some drops of salt solution from one of the two oscillators. Although the actual frequency (period: ˜30 s) and emf (˜±55 mV) is low, our battery is suitable to demonstrate a practical application of oscillating systems in the physical, chemical, or biological laboratory for undergraduates. Interpretation of the phenomenon is given.

  3. Meter circuit for tuning RF amplifiers

    NASA Technical Reports Server (NTRS)

    Longthorne, J. E.

    1973-01-01

    Circuit computes and indicates efficiency of RF amplifier as inputs and other parameters are varied. Voltage drop across internal resistance of ammeter is amplified by operational amplifier and applied to one multiplier input. Other input is obtained through two resistors from positive terminal of power supply.

  4. Mapping the droplet transfer modes for an ER100S-1 GMAW electrode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heald, P.R.; Madigan, R.B.; Siewert, T.A.

    1994-02-01

    Welds were made with a 1.2-mm-diameter AWS ER100S-1 electrode using Ar-2% O[sub 2] shielding gas to map the effects of contact-tube-to-work distance (13, 19 and 25 mm), current, voltage, and wire feed rate on metal transfer. The droplet transfer modes were identified for each map by both the sound of the arc and images from a laser back-lit high-speed video system. The modes were correlated to digital records of the voltage and current fluctuations. The maps contain detailed information on the spray transfer mode, including the boundaries of drop spray, streaming spray and rotating spray modes. The metal transfer modemore » boundaries shifted with an increase in contact-tube-to-work distance. Increasing the contact-tube-to-work distance from 13 to 19 mm resulted in a 15 mm/s increase in the wire feet rate for the globular-to-drop-spray transition.« less

  5. Performance characteristics of lithium primary cells after controlled storage. [on-orbit for energy power supply

    NASA Technical Reports Server (NTRS)

    Deligiannis, F.; Shen, D. H.; Halpert, G.; Ang, V.; Donley, S.

    1991-01-01

    A program was initiated to investigate the effects of storage on the performance of lithium primary cells. Two types of liquid cathode cells were chosen to investigate these effects. The cell types included Li-SOCl2/BCX cells, Li-SO2 cells from two different manufacturers, and a small sample size of 8-year-old Li-SO2 cells. The following measurements are performed at each test interval: open circuit voltage, resistance and weight, microcalorimetry, ac impedance, capacity, and voltage delay. The authors examine the performance characteristics of these cells after one year of controlled storage at two temperatures (10 and 30 C). The Li-SO2 cells experienced little to no voltage and capacity degradation after one year storage. The Li-SOCl2/BCX cells exhibited significant voltage and capacity degradation after 30 C storage. Predischarging shortly prior to use appears to be an effective method of reducing the initial voltage drop. Studies are in progress to correlate ac impedance and microcalorimetry measurements with capacity losses and voltage delay.

  6. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    NASA Astrophysics Data System (ADS)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  7. Maximum time-dependent space-charge limited diode currents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Griswold, M. E.; Fisch, N. J.

    Recent papers claim that a one dimensional (1D) diode with a time-varying voltage drop can transmit current densities that exceed the Child-Langmuir (CL) limit on average, apparently contradicting a previous conjecture that there is a hard limit on the average current density across any 1D diode, as t → ∞, that is equal to the CL limit. However, these claims rest on a different definition of the CL limit, namely, a comparison between the time-averaged diode current and the adiabatic average of the expression for the stationary CL limit. If the current were considered as a function of the maximummore » applied voltage, rather than the average applied voltage, then the original conjecture would not have been refuted.« less

  8. Image registration algorithm for high-voltage electric power live line working robot based on binocular vision

    NASA Astrophysics Data System (ADS)

    Li, Chengqi; Ren, Zhigang; Yang, Bo; An, Qinghao; Yu, Xiangru; Li, Jinping

    2017-12-01

    In the process of dismounting and assembling the drop switch for the high-voltage electric power live line working (EPL2W) robot, one of the key problems is the precision of positioning for manipulators, gripper and the bolts used to fix drop switch. To solve it, we study the binocular vision system theory of the robot and the characteristic of dismounting and assembling drop switch. We propose a coarse-to-fine image registration algorithm based on image correlation, which can improve the positioning precision of manipulators and bolt significantly. The algorithm performs the following three steps: firstly, the target points are marked respectively in the right and left visions, and then the system judges whether the target point in right vision can satisfy the lowest registration accuracy by using the similarity of target points' backgrounds in right and left visions, this is a typical coarse-to-fine strategy; secondly, the system calculates the epipolar line, and then the regional sequence existing matching points is generated according to neighborhood of epipolar line, the optimal matching image is confirmed by calculating the similarity between template image in left vision and the region in regional sequence according to correlation matching; finally, the precise coordinates of target points in right and left visions are calculated according to the optimal matching image. The experiment results indicate that the positioning accuracy of image coordinate is within 2 pixels, the positioning accuracy in the world coordinate system is within 3 mm, the positioning accuracy of binocular vision satisfies the requirement dismounting and assembling the drop switch.

  9. Charged particle detectors with active detector surface for partial energy deposition of the charged particles and related methods

    DOEpatents

    Gerts, David W; Bean, Robert S; Metcalf, Richard R

    2013-02-19

    A radiation detector is disclosed. The radiation detector comprises an active detector surface configured to generate charge carriers in response to charged particles associated with incident radiation. The active detector surface is further configured with a sufficient thickness for a partial energy deposition of the charged particles to occur and permit the charged particles to pass through the active detector surface. The radiation detector further comprises a plurality of voltage leads coupled to the active detector surface. The plurality of voltage leads is configured to couple to a voltage source to generate a voltage drop across the active detector surface and to separate the charge carriers into a plurality of electrons and holes for detection. The active detector surface may comprise one or more graphene layers. Timing data between active detector surfaces may be used to determine energy of the incident radiation. Other apparatuses and methods are disclosed herein.

  10. An Estimation Method of System Voltage Sag Profile using Recorded Sag Data

    NASA Astrophysics Data System (ADS)

    Tanaka, Kazuyuki; Sakashita, Tadashi

    The influence of voltage sag to electric equipment has become big issues because of wider utilization of voltage sensitive devices. In order to reduce the influence of voltage sag appearing at each customer side, it is necessary to recognize the level of receiving voltage drop due to lightning faults for transmission line. However it is hard to measure directly those sag level at every load node. In this report, a new method of efficiently estimating system voltage sag profile is proposed based on symmetrical coordinate. In the proposed method, limited recorded sag data is used as the estimation condition which is recorded at each substation in power systems. From the point of view that the number of the recorded node is generally far less than those of the transmission route, a fast solution method is developed to calculate only recorder faulted voltage by applying reciprocity theorem for Y matrix. Furthermore, effective screening process is incorporated, in which the limited candidate of faulted transmission line can be chosen. Demonstrative results are presented using the IEEJ East10 standard system and actual 1700 bus system. The results show that estimation accuracy is sufficiently acceptable under less computation labor.

  11. Statistical Evaluation of Voltage Variation of Power Distribution System with Clustered Home-Cogeneration Systems

    NASA Astrophysics Data System (ADS)

    Kato, Takeyoshi; Minagata, Atsushi; Suzuoki, Yasuo

    This paper discusses the influence of mass installation of a home co-generation system (H-CGS) using a polymer electrolyte fuel cell (PEFC) on the voltage profile of power distribution system in residential area. The influence of H-CGS is compared with that of photovoltaic power generation systems (PV systems). The operation pattern of H-CGS is assumed based on the electricity and hot-water demand observed in 10 households for a year. The main results are as follows. With the clustered H-CGS, the voltage of each bus is higher by about 1-3% compared with the conventional system without any distributed generators. Because H-CGS tends to increase the output during the early evening, H-CGS contributes to recover the voltage drop during the early evening, resulting in smaller voltage variation of distribution system throughout a day. Because of small rated power output about 1kW, the influence on voltage profile by the clustered H-CGS is smaller than that by the clustered PV systems. The highest voltage during the day time is not so high as compared with the distribution system with the clustered PV systems, even if the reverse power flow from H-CGS is allowed.

  12. Analysis of the Poisson-Nernst-Planck equation in a ball for modeling the Voltage-Current relation in neurobiological microdomains

    NASA Astrophysics Data System (ADS)

    Cartailler, J.; Schuss, Z.; Holcman, D.

    2017-01-01

    The electro-diffusion of ions is often described by the Poisson-Nernst-Planck (PNP) equations, which couple nonlinearly the charge concentration and the electric potential. This model is used, among others, to describe the motion of ions in neuronal micro-compartments. It remains at this time an open question how to determine the relaxation and the steady state distribution of voltage when an initial charge of ions is injected into a domain bounded by an impermeable dielectric membrane. The purpose of this paper is to construct an asymptotic approximation to the solution of the stationary PNP equations in a d-dimensional ball (d = 1 , 2 , 3) in the limit of large total charge. In this geometry the PNP system reduces to the Liouville-Gelfand-Bratú (LGB) equation, with the difference that the boundary condition is Neumann, not Dirichlet, and there is a minus sign in the exponent of the exponential term. The entire boundary is impermeable to ions and the electric field satisfies the compatibility condition of Poisson's equation. These differences replace attraction by repulsion in the LGB equation, thus completely changing the solution. We find that the voltage is maximal in the center and decreases toward the boundary. We also find that the potential drop between the center and the surface increases logarithmically in the total number of charges and not linearly, as in classical capacitance theory. This logarithmic singularity is obtained for d = 3 from an asymptotic argument and cannot be derived from the analysis of the phase portrait. These results are used to derive the relation between the outward current and the voltage in a dendritic spine, which is idealized as a dielectric sphere connected smoothly to the nerve axon by a narrow neck. This is a fundamental microdomain involved in neuronal communication. We compute the escape rate of an ion from the steady density in a ball, which models a neuronal spine head, to a small absorbing window in the sphere. We predict that the current is defined by the narrow neck that is connected to the sphere by a small absorbing window, as suggested by the narrow escape theory, while voltage is controlled by the PNP equations independently of the neck.

  13. Electrodeless electro-hydrodynamic gentle printing of personalized medicines

    NASA Astrophysics Data System (ADS)

    Khusid, Boris; Elele, Ezinwa; Shen, Yueyang

    2010-11-01

    Drop-on-demand (DOD) principle appears to be a particular promising approach for manufacturing personalized treatments carefully tailored to a patient's genetic background. The authors have recently developed a DOD method for gentle printing of personalized medicines. A fluid is infused into an electrically insulating nozzle to form a pendant drop. A sufficiently strong voltage pulse is applied to external electrodes to stretch the pendant drop until it touches an electrically insulating film and forms a liquid bridge. As the liquid bridge is intentionally formed in an unstable configuration, it breaks up, creating two drops, one on the film and the other hanging from the nozzle. To prove the validity and versatility of the method, experiments are conducted on fluids whose viscosity, conductivity, dielectric constant, and surface tension vary over a broad range, respectively: 1-1045 cP, 0.02-290 μS/cm, 9-78, and 41-72 dyn/cm. We present a scaling analysis that captures the essential physics of drop evolution and provides the critical design guidelines. The work was supported by NSF Engineering Research Center on Structured Organic Particulate Systems.

  14. Direct Current Series Circuits: An Educational Module.

    ERIC Educational Resources Information Center

    Sturgess, Keith

    This module was developed as remedial material for physics students who have difficulty understanding concepts of circuits and calculating resistances, and voltage drops and currents. Lists of prerequisite skills and instructional objectives are followed by a pretest (with answers). Students are directed to the subject matter in the module based…

  15. Dc-To-Dc Converter Uses Reverse Conduction Of MOSFET's

    NASA Technical Reports Server (NTRS)

    Gruber, Robert P.; Gott, Robert W.

    1991-01-01

    In modified high-power, phase-controlled, full-bridge, pulse-width-modulated dc-to-dc converters, switching devices power metal oxide/semiconductor field-effect transistors (MOSFET's). Decreases dissipation of power during switching by eliminating approximately 0.7-V forward voltage drop in anti-parallel diodes. Energy-conversion efficiency increased.

  16. Apparatuses and methods for generating electric fields

    DOEpatents

    Scott, Jill R; McJunkin, Timothy R; Tremblay, Paul L

    2013-08-06

    Apparatuses and methods relating to generating an electric field are disclosed. An electric field generator may include a semiconductive material configured in a physical shape substantially different from a shape of an electric field to be generated thereby. The electric field is generated when a voltage drop exists across the semiconductive material. A method for generating an electric field may include applying a voltage to a shaped semiconductive material to generate a complex, substantially nonlinear electric field. The shape of the complex, substantially nonlinear electric field may be configured for directing charged particles to a desired location. Other apparatuses and methods are disclosed.

  17. Superstructures and Electronic Properties of Manganese-Phthalocyanine Molecules on Au(110) from Submonolayer Coverage to Ultrathin Molecular Films.

    PubMed

    Topyła, M; Néel, N; Kröger, J

    2016-07-12

    The adsorption of manganese-phthalocyanine molecules on Au(110) was investigated using a low-temperature scanning tunneling microscope. A rich variety of commensurate superstructures was observed upon increasing the molecule coverage from submonolayers to ultrathin films. All structures were associated with reconstructions of the Au(110) substrate. Molecules adsorbed in the second molecular layer exhibited negative differential conductance occurring symmetrically around zero bias voltage. A double-barrier tunneling model rationalized this observation in terms of a peaked molecular resonance at the Fermi energy together with a voltage drop across the molecular film.

  18. Using Passive Two-Port Networks to Study the Forced Vibrations of Piezoceramic Transducers

    NASA Astrophysics Data System (ADS)

    Karlash, V. L.

    2017-09-01

    A generalization and subsequent development of experimental techniques, including methods of studying the phase-frequency relations between the measured components of admittance and instantaneous power are considered. The conditions of electric loading where electric currents, voltages, or instantaneous powers of constant amplitude in the piezoresonators are specified are numerically modeled. It is particularly established that the advanced Mason circuit with additional switch allows acquiring much more data on the forced vibrations of piezoceramic transducers than the classical circuit. The measured (at an arbitrary frequency) voltage drop across the piezoelement, its pull-up resistor, and at the input of the measuring circuit allow determining, with high accuracy, the current, conductivity, impedance, instantaneous power, and phase shifts when the amplitudes of electric current and voltage are given.

  19. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    PubMed

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  20. Applicability of the Child-Langmuir laws versions for describing the glow discharge cathode sheath in CO2

    NASA Astrophysics Data System (ADS)

    Lisovskiy, Valeriy; Krol, Hennadii; Osmayev, Ruslan; Yegorenkov, Vladimir

    2016-09-01

    This work is devoted to the determination of the law that may be applicable to the description of the cathode sheath in CO2. To this end three versions of the Child-Langmuir law have been considered - a collision free one (for the ions moving through a cathode sheath without collisions with gas molecules) as well as two collision- related versions- one for a constant mean free path of positive ions and one for a constant mobility of positive ions. The current-voltage characteristics and the cathode sheath thickness of the glow discharge in carbon oxide have been simultaneously measured in the pressure range from 0.05 to 1 Torr and with the discharge current values up to 80 mA. The inter-electrode distance has been chosen such that the discharge consists only of the cathode sheath and a small portion of the negative glow, i.e. the experiments have been performed in short tubes. In this case the voltage drop across the cathode sheath is equal approximately to the voltage drop across the electrodes. In the whole range of the discharge conditions we have studied the cathode sheath characteristics are found to obey correctly only to the Child-Langmuir law version with a constant ion mobility. The reason for this phenomenon may be related with a significant conversion of carbon dioxide molecules.

  1. Electro-hydrodynamic printing of drugs onto edible substrates

    NASA Astrophysics Data System (ADS)

    Shen, Yueyang; Elele, Ezinwa; Palle, Prashanth; Khusid, Boris; Basaran, Osman; McGough, Patrick T.; Collins, Robert T.

    2009-11-01

    While most existing drugs are manufactured as tablets using powder processing techniques, there is growing interest in printing drops containing pharmaceutical actives on edible substrates. We have developed a drop-on-demand (DOD) printing method appropriate for either replacing existing manufacturing platforms or enabling personalized medicine that overcomes the various critical challenges facing current DOD technologies. To eliminate adverse effects of electro-chemical reactions at the fluid-electrode interface, the fluid is infused into an electrically insulating nozzle to form a pendant drop that serves as a floating electrode capacitively coupled to external electrodes. A liquid bridge is formed and broken as the voltage applied at the electrode is varied in time. This gentle method for drop deposition has been demonstrated to operate with fluids spanning over three orders of magnitude in viscosity and conductivity. The proposed method has the potential for the evolving field of pharmaceutical and biomedical applications requiring the deposition of fluids at the exact locations with high volume accuracy.

  2. Jumping and trampolining of drops on hydrophobic surfaces, controlling energy transfer by timed electric actuation

    NASA Astrophysics Data System (ADS)

    Wang, Zhantao; Ende, Dirk Van Den; Pit, Arjen; Lagraauw, Rudy; Wijnperle, Daniel; Mugele, Frieder

    2017-11-01

    Electrowetting as a fast and efficient approach of manipulating droplet has found wide applications in microfluidics, and recently the potential of using electrowetting for 3-dimensional microfluidics was also demonstrated. Here the electrowetting-induced jumping of a single droplet on a superhydrophobic surface was studied in both air and ambient decane. The jumping height of the droplet was found to be not only voltage-dependent but also oscillating with the AC-pulse duration. We identify the electrowetting number as a crucial parameter in defining the resonant frequency of the droplet under actuation. Representing the drop by a simple oscillator, we establish a relation between the Eigen frequency of the drop and the optimum actuation time required for most efficient energy conversion. From a general perspective, our experiments illustrate a generic concept how timed actuation in combination with inertia can enhance the flexibility and efficiency of drop manipulation operations. Dutch Technology Foundation (STW) is acknowledged.

  3. METHOD OF LOCATING GROUNDS

    DOEpatents

    Macleish, K.G.

    1958-02-11

    ABS>This patent presents a method for locating a ground in a d-c circult having a number of parallel branches connected across a d-c source or generator. The complete method comprises the steps of locating the ground with reference to the mildpoint of the parallel branches by connecting a potentiometer across the terminals of the circuit and connecting the slider of the potentiometer to ground through a current indicating instrument, adjusting the slider to right or left of the mildpoint so as to cause the instrument to indicate zero, connecting the terminal of the network which is farthest from the ground as thus indicated by the potentiometer to ground through a condenser, impressing a ripple voltage on the circuit, and then measuring the ripple voltage at the midpoint of each parallel branch to find the branch in which is the lowest value of ripple voltage, and then measuring the distribution of the ripple voltage along this branch to determine the point at which the ripple voltage drops off to zero or substantially zero due to the existence of a ground. The invention has particular application where a circuit ground is present which will disappear if the normal circuit voltage is removed.

  4. 2 kV slanted tri-gate GaN-on-Si Schottky barrier diodes with ultra-low leakage current

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Matioli, Elison

    2018-01-01

    This letter reports lateral GaN-on-Si power Schottky barrier diodes (SBDs) with unprecedented voltage-blocking performance by integrating 3-dimensionally a hybrid of tri-anode and slanted tri-gate architectures in their anode. The hybrid tri-anode pins the voltage drop at the Schottky junction (VSCH), despite a large applied reverse bias, fixing the reverse leakage current (IR) of the SBD. Such architecture led to an ultra-low IR of 51 ± 5.9 nA/mm at -1000 V, in addition to a small turn-on voltage (VON) of 0.61 ± 0.03 V. The slanted tri-gate effectively distributes the electric field in OFF state, leading to a remarkably high breakdown voltage (VBR) of -2000 V at 1 μA/mm, constituting a significant breakthrough from existing technologies. The approach pursued in this work reduces the IR and increases the VBR without sacrificing the VON, which provides a technology for high-voltage SBDs, and unveils the unique advantage of tri-gates for advanced power applications.

  5. Frequency Dependence of Low-Voltage Electrowetting Investigated by Impedance Spectroscopy.

    PubMed

    Li, Ying-Jia; Cahill, Brian P

    2017-11-14

    An electrowetting-on-dielectric (EWOD) electrode was developed that facilitates the use of low alternating voltages (≤5 V AC ). This allows online investigation of the frequency dependence of electrowetting by means of impedance spectroscopy. The EWOD electrode is based on a dielectric bilayer consisting of an anodic tantalum pentoxide (Ta 2 O 5 ) thin film (d = 59.35 nm) with a high relative permittivity (ε d = 26.3) and a self-assembled hydrophobic silane monolayer. The frequency dependence of electrowetting was studied using an aqueous μL-sized sessile droplet on the planar EWOD electrode in oil. Experiments using electrochemical impedance spectroscopy and optical imaging indicate the frequency dependence of all three variables in the Young-Lippmann equation: the voltage drop across the dielectric layers, capacitance per unit area, and contact angle under voltage. The electrowetting behavior induced by AC voltages is shown to be well described by the Young-Lippmann equation for AC applications below a frequency threshold. Moreover, the dielectric layers act as a capacitor and the stored electrostatic potential energy is revealed to only partially contribute to the electrowetting.

  6. Magnetic field line reconnection experiments. V - Current disruptions and double layers

    NASA Technical Reports Server (NTRS)

    Stenzel, R. L.; Gekelman, W.; Wild, N.

    1983-01-01

    An investigation is conducted of the stability of a large laboratory plasma current sheet, which has been generated in the process of magnetic field line reconnection, with respect to local current increases. Magnetic flux variations in regions remote from the current sheet generate an inductive voltage in the current loop that drops off inside the plasma in the form of a potential double layer, leading to particle acceleration with velocities much larger than those expected from the steady state electric fields in the plasma. A model for the mechanism of the current disruptions is formulated in which the potential structure leads to ion expulsion, creating a localized density drop. The associated current drop in an inductive circuit drives the potential structure, providing feedback for the disruptive instability. Similarities to, and differences from, magnetospheric substorm phenomena are noted.

  7. Educational Inductive Gravimeter

    ERIC Educational Resources Information Center

    Nunn, John

    2014-01-01

    A simple inductive gravimeter constructed from a rigid plastic pipe and insulated copper wire is described. When a magnet is dropped through the vertically mounted pipe it induces small alternating voltages. These small signals are fed to the microphone input of a typical computer and sampled at a typical rate of 44.1 kHz using a custom computer…

  8. Force and light tuning vertical tunneling current in the atomic layered MoS2.

    PubMed

    Li, Feng; Lu, Zhixing; Lan, Yann-Wen; Jiao, Liying; Xu, Minxuan; Zhu, Xiaoyang; Zhang, Xiankun; Wu, Hualin; Qi, Junjie

    2018-07-06

    In this work, the vertical electrical transport behavior of bilayer MoS 2 under the coupling of force and light was explored by the use of conductive atomic force microscopy. We found that the current-voltage behavior across the tip-MoS 2 -Pt junction is a tunneling current that can be well fitted by a Simmons approximation. The transport behavior is direct tunneling at low bias and Fowler-Nordheim tunneling at high bias, and the transition voltage and tunnel barrier height are extracted. The effect of force and light on the effective band gap of the junction is investigated. Furthermore, the source-drain current drops surprisingly when we continually increase the force, and the dropping point is altered by the provided light. This mechanism is responsible for the tuning of tunneling barrier height and width by force and light. These results provide a new way to design devices that take advantage of ultrathin two-dimensional materials. Ultrashort channel length electronic components that possess tunneling current are important for establishing high-efficiency electronic and optoelectronic systems.

  9. Investigation on emission characteristics of metal-ceramic cathode applied to industrial X-ray diode.

    PubMed

    Xun, Ma; Jianqiang, Yuan; Hongwei, Liu; Hongtao, Li; Lingyun, Wang; Ping, Jiang

    2016-06-01

    The industrial x-ray diode with high impedance configuration is usually adopted to generate repetitive x-ray, but its performance would be worsened due to lower electric field on the cathode of diode when a voltage of several hundreds of kV is applied. To improve its performance, a novel metal-ceramic cathode is proposed in this paper. Key factors (width, relative permittivity of ceramic, and so on) affecting electric field distribution on triple points are analyzed by electrostatic field calculation program, so as to optimize the design of this novel cathode. Experiments are done to study the characteristics including emission current of cathode, diode voltage duration, diode mean dynamic impedance, and diode impedance drop velocity within diode power duration. The results show that metal-ceramic cathode could improve diode performance by enhancing emission current and stabling impedance; the impedance drop velocity of diode with spoke-shaped metal-ceramic cathode was reduced to -5 Ω ns(-1) within diode power duration, comparing to -15 Ω ns(-1) with metal foil cathode.

  10. Freja Studies of the Current-Voltage Relation in Substorm-Related Events

    NASA Technical Reports Server (NTRS)

    Olsson, A.; Andersson, Laila; Eriksson, A. I.; Clemmons, J.; Erlandsson, R. E.; Reeves, G.; Hughes, T.; Murphee, J. S.

    2000-01-01

    Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j(sub II) = KV between field-aligned current density j(sub II) and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V approx. less than 5 kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even i n these conditions, although with values of the field aligned K lower than previously reported (1-5 x 10(exp 11 S/sq m). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study, where the spectra of precipitating electrons --were indirectly inferred by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

  11. Freja studies of the current-voltage relation in substorm-related events

    NASA Astrophysics Data System (ADS)

    Olsson, A.; Andersson, L.; Eriksson, A. I.; Clemmons, J.; Erlandsson, R. E.; Reeves, G.; Huges, T.; Murphee, J. S.

    1998-03-01

    Field-aligned currents and electrostatic potentials play important roles in the coupling between the magnetosphere and the ionosphere. If one assumes that the ionosphere-magnetosphere potential difference is mainly due to the mirror force, one can use the single particle adiabatic kinetic theory to describe the system. From this theory, a linear relationship j∥=KV between field-aligned current density j∥ and potential drop V along the same field line can be derived, provided that the potential drop is not too large and not too small. With rare exceptions, observational tests of this relation have mainly concentrated on quiet magnetospheric situations, with acceleration voltages V<~5kV. Here we use observations from the Freja satellite of precipitating auroral electrons at 1.700 km altitude to study substorm related events, with acceleration voltages up to 20 keV. The observations are found to be consistent with a linear current-voltage relation even in these conditions, although with values of the field aligned K lower than previously reported (1-5×10-11S/m2). This can be explained by lower densities and higher characteristic electron energies in the magnetospheric source region of the precipitating electrons. We analyze the data by three different methods, which are all found to be in general agreement. The results are in agreement with a previous study [Olsson et al., 1996 b], where the spectra of precipitating electrons were indirectly infered by inversion of data from the EISCAT incoherent scatter radar, thereby validating the use of radar data for studies of auroral electrons. Comparisons with previous studies are made, emphasizing the dependence of the results on the type of auroral structure and magnetospheric conditions.

  12. Experimental and theoretical characterization of the voltage distribution generated by deep brain stimulation.

    PubMed

    Miocinovic, Svjetlana; Lempka, Scott F; Russo, Gary S; Maks, Christopher B; Butson, Christopher R; Sakaie, Ken E; Vitek, Jerrold L; McIntyre, Cameron C

    2009-03-01

    Deep brain stimulation (DBS) is an established therapy for the treatment of Parkinson's disease and shows great promise for numerous other disorders. While the fundamental purpose of DBS is to modulate neural activity with electric fields, little is known about the actual voltage distribution generated in the brain by DBS electrodes and as a result it is difficult to accurately predict which brain areas are directly affected by the stimulation. The goal of this study was to characterize the spatial and temporal characteristics of the voltage distribution generated by DBS electrodes. We experimentally recorded voltages around active DBS electrodes in either a saline bath or implanted in the brain of a non-human primate. Recordings were made during voltage-controlled and current-controlled stimulation. The experimental findings were compared to volume conductor electric field models of DBS parameterized to match the different experiments. Three factors directly affected the experimental and theoretical voltage measurements: 1) DBS electrode impedance, primarily dictated by a voltage drop at the electrode-electrolyte interface and the conductivity of the tissue medium, 2) capacitive modulation of the stimulus waveform, and 3) inhomogeneity and anisotropy of the tissue medium. While the voltage distribution does not directly predict the neural response to DBS, the results of this study do provide foundational building blocks for understanding the electrical parameters of DBS and characterizing its effects on the nervous system.

  13. Single Crystal Diamond Needle as Point Electron Source

    PubMed Central

    Kleshch, Victor I.; Purcell, Stephen T.; Obraztsov, Alexander N.

    2016-01-01

    Diamond has been considered to be one of the most attractive materials for cold-cathode applications during past two decades. However, its real application is hampered by the necessity to provide appropriate amount and transport of electrons to emitter surface which is usually achieved by using nanometer size or highly defective crystallites having much lower physical characteristics than the ideal diamond. Here, for the first time the use of single crystal diamond emitter with high aspect ratio as a point electron source is reported. Single crystal diamond needles were obtained by selective oxidation of polycrystalline diamond films produced by plasma enhanced chemical vapor deposition. Field emission currents and total electron energy distributions were measured for individual diamond needles as functions of extraction voltage and temperature. The needles demonstrate current saturation phenomenon and sensitivity of emission to temperature. The analysis of the voltage drops measured via electron energy analyzer shows that the conduction is provided by the surface of the diamond needles and is governed by Poole-Frenkel transport mechanism with characteristic trap energy of 0.2–0.3 eV. The temperature-sensitive FE characteristics of the diamond needles are of great interest for production of the point electron beam sources and sensors for vacuum electronics. PMID:27731379

  14. Monte Carlo modeling and optimization of buffer gas positron traps

    NASA Astrophysics Data System (ADS)

    Marjanović, Srđan; Petrović, Zoran Lj

    2017-02-01

    Buffer gas positron traps have been used for over two decades as the prime source of slow positrons enabling a wide range of experiments. While their performance has been well understood through empirical studies, no theoretical attempt has been made to quantitatively describe their operation. In this paper we apply standard models as developed for physics of low temperature collision dominated plasmas, or physics of swarms to model basic performance and principles of operation of gas filled positron traps. The Monte Carlo model is equipped with the best available set of cross sections that were mostly derived experimentally by using the same type of traps that are being studied. Our model represents in realistic geometry and fields the development of the positron ensemble from the initial beam provided by the solid neon moderator through voltage drops between the stages of the trap and through different pressures of the buffer gas. The first two stages employ excitation of N2 with acceleration of the order of 10 eV so that the trap operates under conditions when excitation of the nitrogen reduces the energy of the initial beam to trap the positrons without giving them a chance to become annihilated following positronium formation. The energy distribution function develops from the assumed distribution leaving the moderator, it is accelerated by the voltage drops and forms beams at several distinct energies. In final stages the low energy loss collisions (vibrational excitation of CF4 and rotational excitation of N2) control the approach of the distribution function to a Maxwellian at room temperature but multiple non-Maxwellian groups persist throughout most of the thermalization. Optimization of the efficiency of the trap may be achieved by changing the pressure and voltage drops and also by selecting to operate in a two stage mode. The model allows quantitative comparisons and test of optimization as well as development of other properties.

  15. Optoelectronic and all-optical multiple memory states in vanadium dioxide

    NASA Astrophysics Data System (ADS)

    Coy, Horacio; Cabrera, Rafmag; Sepúlveda, Nelson; Fernández, Félix E.

    2010-12-01

    Vanadium dioxide exhibits a well-known insulator-to-metal transition during which several of its physical properties change significantly. A hysteresis loop develops for each of them as the material is heated and then cooled through the transition. In this work VO2/SiO2 samples were maintained—by heat sinking—at a selected temperature within the heating branch of the hysteresis loops for resistance and near-infrared transmittance, while brief thermal excursions of the VO2 film were caused by either voltage pulses applied to the film or laser light pulses irradiating the film. These pulses had durations from milliseconds to a few seconds and the resulting drops in resistance or transmittance were easily and repeatably measurable without appreciably affecting their new values. A sequence of equal-duration pulses (for either equal-voltage or equal-irradiation pulses) caused the resistance and infrared transmittance to continue to drop, each time by a smaller amount, and larger energy pulses were required in order to cause drops comparable with the initial one. The ability of the film to change the values of the measurands in this manner with additional pulses was maintained up to a limit defined by the outer hysteresis curve for the measurand in question. The results presented show that a plurality of memory "states" in VO2 can be established or "written" either by voltage pulses or by light pulses applied to the material, and queried or "read" by resistance or transmittance readings, or both. These states were found to remain stable for at least several hours, as long as temperature was kept constant, and are expected to persist indefinitely under this condition. In the all-optical case, if the same light beam is used for writing and reading the memory state, the device is an optical analog of a memristor.

  16. Single-Cell Electric Lysis on an Electroosmotic-Driven Microfluidic Chip with Arrays of Microwells

    PubMed Central

    Jen, Chun-Ping; Amstislavskaya, Tamara G.; Liu, Ya-Hui; Hsiao, Ju-Hsiu; Chen, Yu-Hung

    2012-01-01

    Accurate analysis at the single-cell level has become a highly attractive tool for investigating cellular content. An electroosmotic-driven microfluidic chip with arrays of 30-μm-diameter microwells was developed for single-cell electric lysis in the present study. The cellular occupancy in the microwells when the applied voltage was 5 V (82.4%) was slightly higher than that at an applied voltage of 10 V (81.8%). When the applied voltage was increased to 15 V, the cellular occupancy in the microwells dropped to 64.3%. More than 50% of the occupied microwells contain individual cells. The results of electric lysis experiments at the single-cell level indicate that the cells were gradually lysed as the DC voltage of 30 V was applied; the cell was fully lysed after 25 s. Single-cell electric lysis was demonstrated in the proposed microfluidic chip, which is suitable for high-throughput cell lysis. PMID:22969331

  17. Electrophoretic deposition (EPD): Mechanisms, kinetics, and application to ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarkar, P.; Nicholson, P.S.

    1996-08-01

    The mechanisms of electrophoretic deposition (EPD) are discussed and their shortcomings identified. The kinetics of the processes involved are analyzed for constant-current and constant-voltage conditions. A method of determining the Hamaker constant of suspended particles is developed by modeling the relationship between the particle interaction energy and the suspension stability. A three-probe dc technique is used to map the voltage profile around the depositing electrode, and the results are used to explain discrepancies between the calculated and experimentally observed voltage drops during deposition. A mechanism of deposition is proposed based on DLVO theory and particle double-layer distortion/thinning on application ofmore » a dc field to the suspension. Kinetic equations are developed for constant-current and constant-voltage EPD using mass balance conditions; these are verified by experiments. After the phenomenon is introduced and discussed, a critique of the application of EPD to the synthesis of ceramic shapes and coatings is given.« less

  18. Self-consistent electrostatic simulations of reforming double layers in the downward current region of the aurora

    NASA Astrophysics Data System (ADS)

    Gunell, H.; Andersson, L.; De Keyser, J.; Mann, I.

    2015-10-01

    The plasma on a magnetic field line in the downward current region of the aurora is simulated using a Vlasov model. It is found that an electric field parallel to the magnetic fields is supported by a double layer moving toward higher altitude. The double layer accelerates electrons upward, and these electrons give rise to plasma waves and electron phase-space holes through beam-plasma interaction. The double layer is disrupted when reaching altitudes of 1-2 Earth radii where the Langmuir condition no longer can be satisfied due to the diminishing density of electrons coming up from the ionosphere. During the disruption the potential drop is in part carried by the electron holes. The disruption creates favourable conditions for double layer formation near the ionosphere and double layers form anew in that region. The process repeats itself with a period of approximately 1 min. This period is determined by how far the double layer can reach before being disrupted: a higher disruption altitude corresponds to a longer repetition period. The disruption altitude is, in turn, found to increase with ionospheric density and to decrease with total voltage. The current displays oscillations around a mean value. The period of the oscillations is the same as the recurrence period of the double layer formations. The oscillation amplitude increases with increasing voltage, whereas the mean value of the current is independent of voltage in the 100 to 800 V range covered by our simulations. Instead, the mean value of the current is determined by the electron density at the ionospheric boundary.

  19. Improvement of the grid-connect current quality using novel proportional-integral controller for photovoltaic inverters.

    PubMed

    Cheng, Yuhua; Chen, Kai; Bai, Libing; Yang, Jing

    2014-02-01

    Precise control of the grid-connected current is a challenge in photovoltaic inverter research. Traditional Proportional-Integral (PI) control technology cannot eliminate steady-state error when tracking the sinusoidal signal from the grid, which results in a very high total harmonic distortion in the grid-connected current. A novel PI controller has been developed in this paper, in which the sinusoidal wave is discretized into an N-step input signal that is decided by the control frequency to eliminate the steady state error of the system. The effect of periodical error caused by the dead zone of the power switch and conduction voltage drop can be avoided; the current tracking accuracy and current harmonic content can also be improved. Based on the proposed PI controller, a 700 W photovoltaic grid-connected inverter is developed and validated. The improvement has been demonstrated through experimental results.

  20. Automatic Control of Arc Process for Making Carbon Nanotubes

    NASA Technical Reports Server (NTRS)

    Scott, Carl D.; Pulumbarit, Robert B.; Victor, Joe

    2004-01-01

    An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

  1. Electric field effects on current–voltage relationships in microfluidic channels presenting multiple working electrodes in the weak-coupling limit

    DOE PAGES

    Contento, Nicholas M.; Bohn, Paul W.

    2014-05-23

    While electrochemical methods are well suited for lab-on-a-chip applications, reliably coupling multiple, electrode-controlled processes in a single microfluidic channel remains a considerable challenge, because the electric fields driving electrokinetic flow make it difficult to establish a precisely known potential at the working electrode(s). The challenge of coupling electrochemical detection with microchip electrophoresis is well known; however, the problem is general, arising in other multielectrode arrangements with applications in enhanced detection and chemical processing. Here, we study the effects of induced electric fields on voltammetric behavior in a microchannel containing multiple in-channel electrodes, using a Fe(CN) 6 3/4- model system. Whenmore » an electric field is induced by applying a cathodic potential at one inchannel electrode, the half-wave potential (E 1/2) for the oxidation of ferrocyanide at an adjacent electrode shifts to more negative potentials. The E 1/2 value depends linearly on the electric field current at a separate in-channel electrode. The observed shift in E 1/2 is quantitatively described by a model, which accounts for the change in solution potential caused by the iR drop along the length of the microchannel. The model, which reliably captures changes in electrode location and solution conductivity, apportions the electric field potential between iR drop and electrochemical potential components, enabling the study of microchannel electric field magnitudes at low applied potentials. In the system studied, the iR component of the electric field potential increases exponentially with applied current before reaching an asymptotic value near 80 % of the total applied potential. The methods described will aid in the development and interpretation of future microchip electrochemistry methods, particularly those that benefit from the coupling of electrokinetic and electrochemical phenomena at low voltages.« less

  2. The conversion of a room temperature NaK loop to a high temperature MHD facility for Li/V blanket testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, C.B.; Haglund, R.C.; Miller, M.E.

    1996-12-31

    The Vanadium/Lithium system has been the recent focus of ANL`s Blanket Technology Pro-ram, and for the last several years, ANL`s Liquid Metal Blanket activities have been carried out in direct support of the ITER (International Thermonuclear Experimental Reactor) breeding blanket task area. A key feasibility issue for the ITER Vanadium/Lithium breeding blanket is the Near the development of insulator coatings. Design calculations, Hua and Gohar, show that an electrically insulating layer is necessary to maintain an acceptably low magneto-hydrodynamic (MHD) pressure drop in the current ITER design. Consequently, the decision was made to convert Argonne`s Liquid Metal EXperiment (ALEX) frommore » a 200{degrees}C NaK facility to a 350{degrees}C lithium facility. The upgraded facility was designed to produce MHD pressure drop data, test section voltage distributions, and heat transfer data for mid-scale test sections and blanket mockups at Hartmann numbers (M) and interaction parameters (N) in the range of 10{sup 3} to 10{sup 5} in lithium at 350{degrees}C. Following completion of the upgrade work, a short performance test was conducted, followed by two longer multiple-hour, MHD tests, all at 230{degrees}C. The modified ALEX facility performed up to expectations in the testing. MHD pressure drop and test section voltage distributions were collected at Hartmann numbers of 1000.« less

  3. Conversion of a room temperature NaK loop to a high temperature MHD facility for Li/V blanket testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, C.B.; Haglund, R.C.; Miller, M.E.

    1996-12-31

    The Vanadium/Lithium system has been the recent focus of ANL`s Blanket Technology Program, and for the last several years, ANL`s Liquid Metal Blanket activities have been carried out in direct support of the ITER (International Thermonuclear Experimental Reactor) breeding blanket task area. A key feasibility issue for the ITER Vanadium/Lithium breeding blanket is the development of insulator coatings. Design calculations, Hua and Gohar, show that an electrically insulating layer is necessary to maintain an acceptably low magnetohydrodynamic (MHD) pressure drop in the current ITER design. Consequently, the decision was made to convert Argonne`s Liquid Metal EXperiment (ALEX) from a 200{degree}Cmore » NaK facility to a 350{degree}C lithium facility. The upgraded facility was designed to produce MHD pressure drop data, test section voltage distributions, and heat transfer data for mid-scale test sections and blanket mockups at Hartmann numbers (M) and interaction parameters (N) in the range of 10{sup 3} to 10{sup 5} in lithium at 350{degree}C. Following completion of the upgrade work, a short performance test was conducted, followed by two longer, multiple-hour, MHD tests, all at 230{degree}C. The modified ALEX facility performed up to expectations in the testing. MHD pressure drop and test section voltage distributions were collected at Hartmann numbers of 1000. 4 refs., 2 figs.« less

  4. Influence of high-power nonlinear consumers on electric energy losses in mining high-voltage power line

    NASA Astrophysics Data System (ADS)

    Averbukh, M. A.; Prasol, D. A.

    2018-03-01

    The article elucidates the influence of high-power nonlinear consumers on electric energy losses in a mining high-voltage power line. The object of the study was a fragment of a power supply system of a mining enterprise with hoists. The investigation has assessed the electric energy losses conditioned by nonsinusoidal currents and voltages of the power line over a single hoist operation cycle. Also, the total electric energy losses in a high-voltage power line of a mining enterprise was calculated. The energy losses due to nonsinusoidal currents and voltages over single operation cycle of the cage hoist amount to 36.358 kWh. The presence of such losses increases total technological power and energy losses in the mining high-voltage power line by approximately 5-15%. The total energy losses in the components of the mining enterprise high-voltage power line caused by nonsinusoidal voltage are significant and lead to additional expenses of the company.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, David; Thomsen, Edwin; Li, Bin

    Three flow designs were operated in a 3-cell 1 kW class all vanadium mixed acid redox flow battery. The influence of electrode surface area and flow rate on the coulombic, voltage, and energy efficiency and the pressure drop in the flow circuit will be discussed and correlated to the flow design. Material cost associated with each flow design will also be discussed.

  6. Ultraviolet Rayleigh Scatter Imaging for Spatial Temperature Profiles in Atmospheric Microdischarges

    DTIC Science & Technology

    2014-09-01

    regime and not in a neighboring regime such as an abnormal glow or a corona discharge . As discussed in section 3.1, unlike abnormal discharges or... coronas , normal glows have a voltage drop that is independent of discharge current for several orders of magnitude, which would manifest itself...5 3.2 Discharge Power and Gas Temperature

  7. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    PubMed

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid

    2009-04-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  8. A programmable and portable NMES device for drop foot correction and blood flow assist applications.

    PubMed

    Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; OLaighin, Gearoid

    2007-01-01

    The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor based foot switches and NMES based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.

  9. A robust hybrid fuzzy-simulated annealing-intelligent water drops approach for tuning a distribution static compensator nonlinear controller in a distribution system

    NASA Astrophysics Data System (ADS)

    Bagheri Tolabi, Hajar; Hosseini, Rahil; Shakarami, Mahmoud Reza

    2016-06-01

    This article presents a novel hybrid optimization approach for a nonlinear controller of a distribution static compensator (DSTATCOM). The DSTATCOM is connected to a distribution system with the distributed generation units. The nonlinear control is based on partial feedback linearization. Two proportional-integral-derivative (PID) controllers regulate the voltage and track the output in this control system. In the conventional scheme, the trial-and-error method is used to determine the PID controller coefficients. This article uses a combination of a fuzzy system, simulated annealing (SA) and intelligent water drops (IWD) algorithms to optimize the parameters of the controllers. The obtained results reveal that the response of the optimized controlled system is effectively improved by finding a high-quality solution. The results confirm that using the tuning method based on the fuzzy-SA-IWD can significantly decrease the settling and rising times, the maximum overshoot and the steady-state error of the voltage step response of the DSTATCOM. The proposed hybrid tuning method for the partial feedback linearizing (PFL) controller achieved better regulation of the direct current voltage for the capacitor within the DSTATCOM. Furthermore, in the event of a fault the proposed controller tuned by the fuzzy-SA-IWD method showed better performance than the conventional controller or the PFL controller without optimization by the fuzzy-SA-IWD method with regard to both fault duration and clearing times.

  10. How voltage drops are manifested by lithium ion configurations at interfaces and in thin films on battery electrodes

    DOE PAGES

    Leung, Kevin; Leenheer, Andrew Jay

    2015-04-09

    Battery electrode surfaces are generally coated with electronically insulating solid films of thickness 1-50 nm. Both electrons and Li + can move at the electrode–surface film interface in response to the voltage, which adds complexity to the “electric double layer” (EDL). We also apply Density Functional Theory (DFT) to investigate how the applied voltage is manifested as changes in the EDL at atomic length scales, including charge separation and interfacial dipole moments. Illustrating examples include Li 3PO 4, Li 2CO 3, and Li xMn 2O 4 thin films on Au(111) surfaces under ultrahigh vacuum conditions. Adsorbed organic solvent molecules canmore » strongly reduce voltages predicted in vacuum. We propose that manipulating surface dipoles, seldom discussed in battery studies, may be a viable strategy to improve electrode passivation. We also distinguish the computed potential governing electrons, which is the actual or instantaneous voltage, and the “lithium cohesive energy”-based voltage governing Li content widely reported in DFT calculations, which is a slower-responding self-consistency criterion at interfaces. Furthermore, this distinction is critical for a comprehensive description of electrochemical activities on electrode surfaces, including Li + insertion dynamics, parasitic electrolyte decomposition, and electrodeposition at overpotentials.« less

  11. A robust low quiescent current power receiver for inductive power transmission in bio implants

    NASA Astrophysics Data System (ADS)

    Helalian, Hamid; Pasandi, Ghasem; Jafarabadi Ashtiani, Shahin

    2017-05-01

    In this paper, a robust low quiescent current complementary metal-oxide semiconductor (CMOS) power receiver for wireless power transmission is presented. This power receiver consists of three main parts including rectifier, switch capacitor DC-DC converter and low-dropout regulator (LDO) without output capacitor. The switch capacitor DC-DC converter has variable conversion ratios and synchronous controller that lets the DC-DC converter to switch among five different conversion ratios to prevent output voltage drop and LDO regulator efficiency reduction. For all ranges of output current (0-10 mA), the voltage regulator is compensated and is stable. Voltage regulator stabilisation does not need the off-chip capacitor. In addition, a novel adaptive biasing frequency compensation method for low dropout voltage regulator is proposed in this paper. This method provides essential minimum current for compensation and reduces the quiescent current more effectively. The power receiver was designed in a 180-nm industrial CMOS technology, and the voltage range of the input is from 0.8 to 2 V, while the voltage range of the output is from 1.2 to 1.75 V, with a maximum load current of 10 mA, the unregulated efficiency of 79.2%, and the regulated efficiency of 64.4%.

  12. Satellite observations of surface temperature during the March 2015 total solar eclipse.

    PubMed

    Good, Elizabeth

    2016-09-28

    The behaviour of remotely sensed land surface temperatures (LSTs) from the spinning-enhanced visible and infrared imager (SEVIRI) during the total solar eclipse of 20 March 2015 is analysed over Europe. LST is found to drop by up to several degrees Celcius during the eclipse, with the minimum LST occurring just after the eclipse mid-point (median=+1.5 min). The drop in LST is typically larger than the drop in near-surface air temperatures reported elsewhere, and correlates with solar obscuration (r=-0.47; larger obscuration = larger LST drop), eclipse duration (r=-0.62; longer duration = larger LST drop) and time (r=+0.37; earlier eclipse = larger LST drop). Locally, the LST drop is also correlated with vegetation (up to r=+0.6), with smaller LST drops occurring over more vegetated surfaces. The LSTs at locations near the coast and at higher elevation are also less affected by the eclipse. This study covers the largest area and uses the most observations of eclipse-induced surface temperature drops to date, and is the first full characterization of satellite LST during an eclipse (known to the author). The methods described could be applied to Geostationary Operational Environmental Satellite (GOES) LST data over North America during the August 2017 total solar eclipse.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Author(s).

  13. Satellite observations of surface temperature during the March 2015 total solar eclipse

    PubMed Central

    2016-01-01

    The behaviour of remotely sensed land surface temperatures (LSTs) from the spinning-enhanced visible and infrared imager (SEVIRI) during the total solar eclipse of 20 March 2015 is analysed over Europe. LST is found to drop by up to several degrees Celcius during the eclipse, with the minimum LST occurring just after the eclipse mid-point (median=+1.5 min). The drop in LST is typically larger than the drop in near-surface air temperatures reported elsewhere, and correlates with solar obscuration (r=−0.47; larger obscuration = larger LST drop), eclipse duration (r=−0.62; longer duration = larger LST drop) and time (r=+0.37; earlier eclipse = larger LST drop). Locally, the LST drop is also correlated with vegetation (up to r=+0.6), with smaller LST drops occurring over more vegetated surfaces. The LSTs at locations near the coast and at higher elevation are also less affected by the eclipse. This study covers the largest area and uses the most observations of eclipse-induced surface temperature drops to date, and is the first full characterization of satellite LST during an eclipse (known to the author). The methods described could be applied to Geostationary Operational Environmental Satellite (GOES) LST data over North America during the August 2017 total solar eclipse. This article is part of the themed issue ‘Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse’. PMID:27550764

  14. Features of current-voltage characteristic of nonequilibrium trench MOS barrier Schottky diode

    NASA Astrophysics Data System (ADS)

    Mamedov, R. K.; Aslanova, A. R.

    2018-06-01

    The trench MOS barrier Schottky diodes (TMBS diode) under the influence of the voltage drop of the additional electric field (AEF) appearing in the near-contact region of the semiconductor are in a nonequilibrium state and their closed external circuit flows currents in the absence of an external voltage. When an external voltage is applied to the TMBS diode, the current transmission is described by the thermionic emission theory with a specific feature. Both forward and reverse I-V characteristics of the TMBS diode consist of two parts. In the initial first part of the forward I-V characteristic there are no forward currents, but reverse saturation currents flow, in its subsequent second part the currents increase exponentially with the voltage. In the initial first part of the reverse I-V characteristic, the currents increase in an abrupt way and in the subsequent second part the saturation currents flow under the action of the image force. The mathematical expressions for forward and reverse I-V characteristic of the TMBS diode and also narrow or nanostructure Schottky diode are proposed, which are in good agreement with the results of experimental and calculated I-V characteristics.

  15. 40 CFR Table 7 to Subpart Ddddd of... - Establishing Operating Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... Particulate matter, mercury, or total selected metals a. Wet scrubber operating parameters i. Establish a site... drop and liquid flow rate monitors and the particulate matter, mercury, or total selected metals... from the pressure drop and liquid flow rate monitors and the particulate matter, mercury, or total...

  16. HOLLOTRON switch for megawatt lightweight space inverters

    NASA Technical Reports Server (NTRS)

    Poeschel, R. L.; Goebel, D. M.; Schumacher, R. W.

    1991-01-01

    The feasibility of satisfying the switching requirements for a megawatt ultralight inverter system using HOLLOTRON switch technology was determined. The existing experimental switch hardware was modified to investigate a coaxial HOLLOTRON switch configuration and the results were compared with those obtained for a modified linear HOLLOTRON configuration. It was concluded that scaling the HOLLOTRON switch to the current and voltage specifications required for a megawatt converter system is indeed feasible using a modified linear configuration. The experimental HOLLOTRON switch operated at parameters comparable to the scaled coaxial HOLLOTRON. However, the linear HOLLOTRON data verified the capability for meeting all the design objectives simultaneously including current density (greater than 2 A/sq cm), voltage (5 kV), switching frequency (20 kHz), switching time (300 ns), and forward voltage drop (less than or equal to 20 V). Scaling relations were determined and a preliminary design was completed for an engineering model linear HOLLOTRON switch to meet the megawatt converter system specifications.

  17. Tests of a low-pressure switch protected by a saturating inductor

    NASA Astrophysics Data System (ADS)

    Lauer, E. J.; Birx, D. L.

    Low pressure switches and magnetic switches were tested as possible replacements for the high pressure switches currently used on Experimental Test Accelerator and Advanced Test Accelerator. When the low pressure switch is used with a low impedance transmission line, runaway electrons form a pinched electron beam which damages the anode. The use of the low pressure switch as the first switch in the pulsed power chain was tested; i.e., the switch would be used to connect a charged capacitor across the primary winding of a step up transformer. An inductor with a saturating core is connected in series so that, initially, there is a large inductive voltage drop. As a result, there is small voltage across the switch. By the time the inductor core saturates, the switch has developed sufficient ionization so that the switch voltage remains small, even with peak current, and an electron beam is not produced.

  18. Use of the electrosurgical unit in a carbon dioxide atmosphere.

    PubMed

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J; Eidson, Jack L; Paolino, David V

    2016-01-01

    The electrosurgical unit (ESU) utilizes an electrical discharge to cut and coagulate tissue and is often held above the surgical site, causing a spark to form. The voltage at which the spark is created, termed the breakdown voltage, is governed by the surrounding gaseous environment. Surgeons are now utilizing the ESU laparoscopically with carbon dioxide insufflation, potentially altering ESU operating characteristics. This study examines the clinical implications of altering gas composition by measuring the spark gap distance as a marker of breakdown voltage and use of the ESU on a biologic model, both in room air and carbon dioxide. Paschen's Law predicted a 35% decrease in gap distance in carbon dioxide, while testing revealed an average drop of 37-47% as compared to air. However, surgical model testing revealed no perceivable clinical difference. Electrosurgery can be performed in carbon dioxide environments, although surgeons should be aware of potentially altered ESU performance.

  19. Radio frequency-assisted fast superconducting switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solovyov, Vyacheslav; Li, Qiang

    A radio frequency-assisted fast superconducting switch is described. A superconductor is closely coupled to a radio frequency (RF) coil. To turn the switch "off," i.e., to induce a transition to the normal, resistive state in the superconductor, a voltage burst is applied to the RF coil. This voltage burst is sufficient to induce a current in the coupled superconductor. The combination of the induced current with any other direct current flowing through the superconductor is sufficient to exceed the critical current of the superconductor at the operating temperature, inducing a transition to the normal, resistive state. A by-pass MOSFET maymore » be configured in parallel with the superconductor to act as a current shunt, allowing the voltage across the superconductor to drop below a certain value, at which time the superconductor undergoes a transition to the superconducting state and the switch is reset.« less

  20. Brake Failure from Residual Magnetism in the Mars Exploration Rover Lander Petal Actuator

    NASA Technical Reports Server (NTRS)

    Jandura, Louise

    2004-01-01

    In January 2004, two Mars Exploration Rover spacecraft arrived at Mars. Each safely delivered an identical rover to the Martian surface in a tetrahedral lander encased in airbags. Upon landing, the airbags deflated and three Lander Petal Actuators opened the three deployable Lander side petals enabling the rover to exit the Lander. Approximately nine weeks prior to the scheduled launch of the first spacecraft, one of these mission-critical Lander Petal Actuators exhibited a brake stuck-open failure during its final flight stow at Kennedy Space Center. Residual magnetism was the definitive conclusion from the failure investigation. Although residual magnetism was recognized as an issue in the design, the lack of an appropriately specified lower bound on brake drop-out voltage inhibited the discovery of this problem earlier in the program. In addition, the brakes had more unit-to-unit variation in drop-out voltage than expected, likely due to a larger than expected variation in the magnetic properties of the 15-5 PH stainless steel brake plates. Failure analysis and subsequent rework of two other Lander Petal Actuators with marginal brakes was completed in three weeks, causing no impact to the launch date.

  1. Gate field plate IGBT with trench accumulation layer for extreme injection enhancement

    NASA Astrophysics Data System (ADS)

    Xu, Xiaorui; Chen, Wanjun; Liu, Chao; Chen, Nan; Tao, Hong; Shi, Yijun; Ma, Yinchang; Zhou, Qi; Zhang, Bo

    2017-04-01

    A gate field plate IGBT (GFP-IGBT) with extreme injection enhancement is proposed and verified using TCAD simulations. The GFP-IGBT features a gate field plate (GFP) inserted into n-drift region directly and a tiny P-base region separated from the GFP. In the ON-state, the accumulation layer is formed near to not only the bottom but also the side of the trench, which enhances electron injection efficiency. And the tiny P-base region reduces the holes extracted by reverse-biased P-base/N-drift junction. Both the GFP and tiny P-base contribute to achieving extreme injection enhancement, leading to a low forward voltage drop. In the OFF-state, due to the low stored charges in N-buffer layer, GFP-IGBT shows a short current fall time, leading to a decrease of turn-off loss. The simulation results show that, compared with the conventional IGBT, the GFP-IGBT offers a forward voltage drop reduction of 25% or current fall time reduction of 89% (i.e. turn-off loss reduction of 53%), resulting in low power loss. The excellent device performance, coupled with a commercial IGBT-compatible fabrication process, makes the proposed GFP-IGBT a promising candidate for power switching applications.

  2. Ion extraction capabilities of closely spaced grids

    NASA Technical Reports Server (NTRS)

    Rovang, D. C.; Wilbur, P. J.

    1982-01-01

    The ion extraction capabilities of accelerator systems with small screen hole diameters (less than 2.0 mm) are investigated at net-accelerating voltages of 100, 300, and 500 V. Results show that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 1.0 mm, but impingement-limited performance was found to be dependent on the grid separation distance, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained using small hole diameters and closely spaced grids indicate a new mode of grid operation where high current density operation can be achieved with a specified net acceleration voltage by operating the grids at a high rather than low net-to-total acceleration voltage. Beam current densities as high as 25 mA/sq cm were obtained using grids with 1.0 mm diameter holes operating at a net accelerating voltage of 500 V.

  3. Self-Powered Viscosity and Pressure Sensing in Microfluidic Systems Based on the Piezoelectric Energy Harvesting of Flowing Droplets.

    PubMed

    Wang, Zhao; Tan, Lun; Pan, Xumin; Liu, Gao; He, Yahua; Jin, Wenchao; Li, Meng; Hu, Yongming; Gu, Haoshuang

    2017-08-30

    The rapid development of microscaled piezoelectric energy harvesters has provided a simple and highly efficient way for building self-powered sensor systems through harvesting the mechanical energy from the ambient environment. In this work, a self-powered microfluidic sensor that can harvest the mechanical energy of the fluid and simultaneously monitor their characteristics was fabricated by integrating the flexible piezoelectric poly(vinylidene fluoride) (PVDF) nanofibers with the well-designed microfluidic chips. Those devices could generate open-circuit high output voltage up to 1.8 V when a droplet of water is flowing past the suspended PVDF nanofibers and result in their periodical deformations. The impulsive output voltage signal allowed them to be utilized for droplets or bubbles counting in the microfluidic systems. Furthermore, the devices also exhibited self-powered sensing behavior due to the decreased voltage amplitude with increasing input pressure and liquid viscosity. The drop of output voltage could be attributed to the variation of flow condition and velocity of the droplets, leading to the reduced deformation of the piezoelectric PVDF layer and the decrease of the generated piezoelectric potential.

  4. Improvable method for Halon 1301 concentration measurement based on infrared absorption

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Lu, Song; Guan, Yu

    2015-09-01

    Halon 1301 has attached much interest because of its pervasive use as an effective fire suppressant agent in aircraft related fires, and the study of fire suppressant agent concentration measurement is especially of interest. In this work, a Halon 1301 concentration measurement method based on the Beer-Lambert law is developed. IR light is transmitted through mixed gas, and the light intensity with and without the agent present is measured. The intensity ratio is a function of the volume percentage of Halon 1301, and the voltage output of the detector is proportional to light intensity. As such, the relationship between the volume percentage and voltage ratio can be established. The concentration measurement system shows a relative error of the system less than ±2.50%, and a full scale error within 1.20%. This work also discusses the effect of temperature and relative humidity (RH) on the calibration. The experimental results of voltage ratio versus Halon 1301 volume percentage relationship show that the voltage ratio drops significantly as temperature rises from 25 to 100 °C, and it decreases as RH rises from 0% to 100%.

  5. How the charge-neutrality level of interface states controls energy level alignment in cathode contacts of organic bulk-heterojunction solar cells.

    PubMed

    Guerrero, Antonio; Marchesi, Luís F; Boix, Pablo P; Ruiz-Raga, Sonia; Ripolles-Sanchis, Teresa; Garcia-Belmonte, Germà; Bisquert, Juan

    2012-04-24

    Electronic equilibration at the metal-organic interface, leading to equalization of the Fermi levels, is a key process in organic optoelectronic devices. How the energy levels are set across the interface determines carrier extraction at the contact and also limits the achievable open-circuit voltage under illumination. Here, we report an extensive investigation of the cathode energy equilibration of organic bulk-heterojunction solar cells. We show that the potential to balance the mismatch between the cathode metal and the organic layer Fermi levels is divided into two contributions: spatially extended band bending in the organic bulk and voltage drop at the interface dipole layer caused by a net charge transfer. We scan the operation of the cathode under a varied set of conditions, using metals of different work functions in the range of ∼2 eV, different fullerene acceptors, and several cathode interlayers. The measurements allow us to locate the charge-neutrality level within the interface density of sates and calculate the corresponding dipole layer strength. The dipole layer withstands a large part of the total Fermi level mismatch when the polymer:fullerene blend ratio approaches ∼1:1, producing the practical alignment between the metal Fermi level and the charge-neutrality level. Origin of the interface states is linked with fullerene reduced molecules covering the metal contact. The dipole contribution, and consequently the band bending, is highly sensitive to the nature and amount of fullerene molecules forming the interface density of states. Our analysis provides a detailed picture of the evolution of the potentials in the bulk and the interface of the solar cell when forward voltage is applied or when photogeneration takes place.

  6. High temperature spectral emissivity measurement using integral blackbody method

    NASA Astrophysics Data System (ADS)

    Pan, Yijie; Dong, Wei; Lin, Hong; Yuan, Zundong; Bloembergen, Pieter

    2016-10-01

    Spectral emissivity is a critical material's thermos-physical property for heat design and radiation thermometry. A prototype instrument based upon an integral blackbody method was developed to measure material's spectral emissivity above 1000 °. The system was implemented with an optimized commercial variable-high-temperature blackbody, a high speed linear actuator, a linear pyrometer, and an in-house designed synchronization circuit. A sample was placed in a crucible at the bottom of the blackbody furnace, by which the sample and the tube formed a simulated blackbody which had an effective total emissivity greater than 0.985. During the measurement, the sample was pushed to the end opening of the tube by a graphite rod which was actuated through a pneumatic cylinder. A linear pyrometer was used to monitor the brightness temperature of the sample surface through the measurement. The corresponding opto-converted voltage signal was fed and recorded by a digital multi-meter. A physical model was proposed to numerically evaluate the temperature drop along the process. Tube was discretized as several isothermal cylindrical rings, and the temperature profile of the tube was measurement. View factors between sample and rings were calculated and updated along the whole pushing process. The actual surface temperature of the sample at the end opening was obtained. Taking advantages of the above measured voltage profile and the calculated true temperature, spectral emissivity under this temperature point was calculated.

  7. Design techniques for a stable operation of cryogenic field-programmable gate arrays.

    PubMed

    Homulle, Harald; Visser, Stefan; Patra, Bishnu; Charbon, Edoardo

    2018-01-01

    In this paper, we show how a deep-submicron field-programmable gate array (FPGA) can be operated more stably at extremely low temperatures through special firmware design techniques. Stability at low temperatures is limited through long power supply wires and reduced performance of various printed circuit board components commonly employed at room temperature. Extensive characterization of these components shows that the majority of decoupling capacitor types and voltage regulators are not well behaved at cryogenic temperatures, asking for an ad hoc solution to stabilize the FPGA supply voltage, especially for sensitive applications. Therefore, we have designed a firmware that enforces a constant power consumption, so as to stabilize the supply voltage in the interior of the FPGA. The FPGA is powered with a supply at several meters distance, causing significant resistive voltage drop and thus fluctuations on the local supply voltage. To achieve the stabilization, the variation in digital logic speed, which directly corresponds to changes in supply voltage, is constantly measured and corrected for through a tunable oscillator farm, implemented on the FPGA. The impact of the stabilization technique is demonstrated together with a reconfigurable analog-to-digital converter (ADC), completely implemented in the FPGA fabric and operating at 15 K. The ADC performance can be improved by at most 1.5 bits (effective number of bits) thanks to the more stable supply voltage. The method is versatile and robust, enabling seamless porting to other FPGA families and configurations.

  8. Design techniques for a stable operation of cryogenic field-programmable gate arrays

    NASA Astrophysics Data System (ADS)

    Homulle, Harald; Visser, Stefan; Patra, Bishnu; Charbon, Edoardo

    2018-01-01

    In this paper, we show how a deep-submicron field-programmable gate array (FPGA) can be operated more stably at extremely low temperatures through special firmware design techniques. Stability at low temperatures is limited through long power supply wires and reduced performance of various printed circuit board components commonly employed at room temperature. Extensive characterization of these components shows that the majority of decoupling capacitor types and voltage regulators are not well behaved at cryogenic temperatures, asking for an ad hoc solution to stabilize the FPGA supply voltage, especially for sensitive applications. Therefore, we have designed a firmware that enforces a constant power consumption, so as to stabilize the supply voltage in the interior of the FPGA. The FPGA is powered with a supply at several meters distance, causing significant resistive voltage drop and thus fluctuations on the local supply voltage. To achieve the stabilization, the variation in digital logic speed, which directly corresponds to changes in supply voltage, is constantly measured and corrected for through a tunable oscillator farm, implemented on the FPGA. The impact of the stabilization technique is demonstrated together with a reconfigurable analog-to-digital converter (ADC), completely implemented in the FPGA fabric and operating at 15 K. The ADC performance can be improved by at most 1.5 bits (effective number of bits) thanks to the more stable supply voltage. The method is versatile and robust, enabling seamless porting to other FPGA families and configurations.

  9. Radiation Effects on DC-DC Converters

    NASA Technical Reports Server (NTRS)

    Zhang, De-Xin; AbdulMazid, M. D.; Attia, John O.; Kankam, Mark D. (Technical Monitor)

    2001-01-01

    In this work, several DC-DC converters were designed and built. The converters are Buck Buck-Boost, Cuk, Flyback, and full-bridge zero-voltage switched. The total ionizing dose radiation and single event effects on the converters were investigated. The experimental results for the TID effects tests show that the voltages of the Buck Buck-Boost, Cuk, and Flyback converters increase as total dose increased when using power MOSFET IRF250 as a switching transistor. The change in output voltage with total dose is highest for the Buck converter and the lowest for Flyback converter. The trend of increase in output voltages with total dose in the present work agrees with those of the literature. The trends of the experimental results also agree with those obtained from PSPICE simulation. For the full-bridge zero-voltage switch converter, it was observed that the dc-dc converter with IRF250 power MOSFET did not show a significant change of output voltage with total dose. In addition, for the dc-dc converter with FSF254R4 radiation-hardened power MOSFET, the output voltage did not change significantly with total dose. The experimental results were confirmed by PSPICE simulation that showed that FB-ZVS converter with IRF250 power MOSFET's was not affected with the increase in total ionizing dose. Single Event Effects (SEE) radiation tests were performed on FB-ZVS converters. It was observed that the FB-ZVS converter with the IRF250 power MOSFET, when the device was irradiated with Krypton ion with ion-energy of 150 MeV and LET of 41.3 MeV-square cm/mg, the output voltage increased with the increase in fluence. However, for Krypton with ion-energy of 600 MeV and LET of 33.65 MeV-square cm/mg, and two out of four transistors of the converter were permanently damaged. The dc-dc converter with FSF254R4 radiation hardened power MOSFET's did not show significant change at the output voltage with fluence while being irradiated by Krypton with ion energy of 1.20 GeV and LET of 25.97 MeV-square cm/mg. This might be due to fact that the device is radiation hardened.

  10. Proton-irradiation technology for high-frequency high-current silicon welding diode manufacturing

    NASA Astrophysics Data System (ADS)

    Lagov, P. B.; Drenin, A. S.; Zinoviev, M. A.

    2017-05-01

    Different proton irradiation regimes were tested to provide more than 20 kHz-frequency, soft reverse recovery “snap-less” behavior, low forward voltage drop and leakage current for 50 mm diameter 7 kA/400 V welding diode Al/Si/Mo structure. Silicon diode with such parameters is very suitable for high frequency resistance welding machines of new generation for robotic welding.

  11. Electrical potential difference during laser welding

    NASA Astrophysics Data System (ADS)

    Zohm, H.; Ambrosy, G.; Lackner, K.

    2015-01-01

    We present a new model for the generation of thermoelectric currents during laser welding, taking into account sheath effects at both contact points as well as the potential drop within the quasi-neutral plasma generated by the laser. We show that the model is in good agreement with experimentally measured electric potential difference between the hot and the cold parts of the welded workpiece. In particular, all three elements of the model are needed to correctly reproduce the sign of the measured voltage difference. The mechanism proposed relies on the temperature dependence of the electron flux from the plasma to the workpiece and hence does not need thermoemission from the workpiece surface to explain the experimentally observed sign and magnitude of the potential drop.

  12. Novel Dry-Type Glucose Sensor Based on a Metal-Oxide-Semiconductor Capacitor Structure with Horseradish Peroxidase + Glucose Oxidase Catalyzing Layer

    NASA Astrophysics Data System (ADS)

    Lin, Jing-Jenn; Wu, You-Lin; Hsu, Po-Yen

    2007-10-01

    In this paper, we present a novel dry-type glucose sensor based on a metal-oxide-semiconductor capacitor (MOSC) structure using SiO2 as a gate dielectric in conjunction with a horseradish peroxidase (HRP) + glucose oxidase (GOD) catalyzing layer. The tested glucose solution was dropped directly onto the window opened on the SiO2 layer, with a coating of HRP + GOD catalyzing layer on top of the gate dielectric. From the capacitance-voltage (C-V) characteristics of the sensor, we found that the glucose solution can induce an inversion layer on the silicon surface causing a gate leakage current flowing along the SiO2 surface. The gate current changes Δ I before and after the drop of glucose solution exhibits a near-linear relationship with increasing glucose concentration. The Δ I sensitivity is about 1.76 nA cm-2 M-1, and the current is quite stable 20 min after the drop of the glucose solution is tested.

  13. Electron transport in Bi2Se3 ultra thin films

    NASA Astrophysics Data System (ADS)

    Bauer, Sebastian; Bernhart, Alexander M.; Bobisch, Christian A.

    2018-02-01

    We studied the electronic transport properties of a 4 QL thin Bi2Se3 film in the hybridized phase on Si(111) by scanning tunneling potentiometry. When a transverse voltage is applied, the film exhibits a homogeneous electric field on the nm scale. In addition, thermovoltage signals with lateral nm variations are found which result from sample heating by the transverse current. The thermovoltage signals are directly correlated to morphological structures on the surface, i.e. step edges, and indicate a lateral variation of the local density of states at the Bi2Se3 surface. No discernible voltage drops appear at the surface so that the whole film serves as a current carrying medium and scattering at surface defects is less important.

  14. Spin-Caloritronic Batteries

    NASA Astrophysics Data System (ADS)

    Yu, Xiao-Qin; Zhu, Zhen-Gang; Su, Gang; Jauho, A.-P.

    2017-11-01

    The thermoelectric performance of a topological energy converter is analyzed. The H -shaped device is based on a combination of transverse topological effects involving the spin: the inverse spin Hall effect and the spin Nernst effect. The device can convert a temperature drop in one arm into an electric power output in the other arm. Analytical expressions for the output voltage, the figure of merit (Z T ), and energy-converting efficiency are reported. We show that the output voltage and the Z T can be tuned by the geometry of the device and the physical properties of the material. Importantly, contrary to a conventional thermoelectric device, here a low electric conductivity may, in fact, enhance the Z T value, thereby opening a path to strategies in optimizing the figure of merit.

  15. Real-time detection of hazardous materials in air

    NASA Astrophysics Data System (ADS)

    Schechter, Israel; Schroeder, Hartmut; Kompa, Karl L.

    1994-03-01

    A new detection system has been developed for real-time analysis of organic compounds in ambient air. It is based on multiphoton ionization by an unfocused laser beam in a single parallel-plate device. Thus, the ionization volume can be relatively large. The amount of laser created ions is determined quantitatively from the induced total voltage drop between the biased plates (Q equals (Delta) V(DOT)C). Mass information is obtained from computer analysis of the time-dependent signal. When a KrF laser (5 ev) is used, most of the organic compounds can be ionized in a two-photon process, but none of the standard components of atmospheric air are ionized by this process. Therefore, this instrument may be developed as a `sniffer' for organic materials. The method has been applied for benzene analysis in air. The detection limit is about 10 ppb. With a simple preconcentration technique the detection limit can be decreased to the sub-ppb range. Simple binary mixtures are also resolved.

  16. Specifics of Pulsed Arc Welding Power Supply Performance Based On A Transistor Switch

    NASA Astrophysics Data System (ADS)

    Krampit, N. Yu; Kust, T. S.; Krampit, M. A.

    2016-08-01

    Specifics of designing a pulsed arc welding power supply device are presented in the paper. Electronic components for managing large current was analyzed. Strengths and shortcomings of power supply circuits based on thyristor, bipolar transistor and MOSFET are outlined. As a base unit for pulsed arc welding was chosen MOSFET transistor, which is easy to manage. Measures to protect a transistor are given. As for the transistor control device is a microcontroller Arduino which has a low cost and adequate performance of the work. Bead transfer principle is to change the voltage on the arc in the formation of beads on the wire end. Microcontroller controls transistor when the arc voltage reaches the threshold voltage. Thus there is a separation and transfer of beads without splashing. Control strategies tested on a real device and presented. The error in the operation of the device is less than 25 us, it can be used controlling drop transfer at high frequencies (up to 1300 Hz).

  17. Charge Characteristics of Rechargeable Batteries

    NASA Astrophysics Data System (ADS)

    Maheswaranathan, Ponn; Kelly, Cormac

    2014-03-01

    Rechargeable batteries play important role in technologies today and they are critical for the future. They are used in many electronic devices and their capabilities need to keep up with the accelerated pace of technology. Efficient energy capture and storage is necessary for the future rechargeable batteries. Charging and discharging characteristics of three popular commercially available re-chargeable batteries (NiCd, NiMH, and Li Ion) are investigated and compared with regular alkaline batteries. Pasco's 850 interface and their voltage & current sensors are used to monitor the current through and the potential difference across the battery. The discharge current and voltage stayed fairly constant until the end, with a slightly larger drop in voltage than current, which is more pronounced in the alkaline batteries. After 25 charge/discharge cycling there is no appreciable loss of charge capacities in the Li Ion battery. Energy densities, cycle characteristics, and memory effects will also be presented. Sponsored by the South Carolina Governor's school for Science and Mathematics under the Summer Program for Research Interns program.

  18. Diminiode thermionic conversion with 111-iridium electrodes

    NASA Technical Reports Server (NTRS)

    Koeger, E. W.; Bair, V. L.; Morris, J. F.

    1976-01-01

    Preliminary data indicating thermionic-conversion potentialities for a 111-iridium emitter and collector spaced 0.2 mm apart are presented. These results comprise output densities of current and of power as functions of voltage for three sets of emitter, collector, and reservoir temperatures: 1553, 944, 561 K; 1605, 898, 533 K; and 1656, 1028, 586 K. For the 1605 K evaluation, estimates produced work-function values of 2.22 eV for the emitter and 1.63 eV for the collector with a 2.0-eV barrier index (collector work function plus interelectrode voltage drop) corresponding to the maximum output of 5.5 W/sq cm at 0.24 volt. The current, voltage curve for the 1656 K 111-iridium diminiode yields a 6.2 W/sq cm maximum at 0.25 volt and is comparable with the 1700 K envelope for a diode with an etched-rhenium emitter and a 0.025-mm electrode gap made by TECO and evaluated by NASA.

  19. [Computation of the cross-sectional area of the cable in the power circuit of the X-ray machine].

    PubMed

    Meng, Xin-min; Feng, Da-yu

    2007-01-01

    The source impedance of the power circuit in the x-ray machine is analyzed in the paper and based on the voltage drop generated by the impedance, the cross-sectional area of the cable is calculated. In the end, the cross-sectional areas of the cables, corresponding to their respective distances between the transformers and the switchboards are given.

  20. Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

    PubMed

    Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha

    2015-10-01

    Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.

  1. Integrating a Silicon Solar Cell with a Triboelectric Nanogenerator via a Mutual Electrode for Harvesting Energy from Sunlight and Raindrops.

    PubMed

    Liu, Yuqiang; Sun, Na; Liu, Jiawei; Wen, Zhen; Sun, Xuhui; Lee, Shuit-Tong; Sun, Baoquan

    2018-03-27

    Solar cells, as promising devices for converting light into electricity, have a dramatically reduced performance on rainy days. Here, an energy harvesting structure that integrates a solar cell and a triboelectric nanogenerator (TENG) device is built to realize power generation from both sunlight and raindrops. A heterojunction silicon (Si) solar cell is integrated with a TENG by a mutual electrode of a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) film. Regarding the solar cell, imprinted PEDOT:PSS is used to reduce light reflection, which leads to an enhanced short-circuit current density. A single-electrode-mode water-drop TENG on the solar cell is built by combining imprinted polydimethylsiloxane (PDMS) as a triboelectric material combined with a PEDOT:PSS layer as an electrode. The increasing contact area between the imprinted PDMS and water drops greatly improves the output of the TENG with a peak short-circuit current of ∼33.0 nA and a peak open-circuit voltage of ∼2.14 V, respectively. The hybrid energy harvesting system integrated electrode configuration can combine the advantages of high current level of a solar cell and high voltage of a TENG device, promising an efficient approach to collect energy from the environment in different weather conditions.

  2. Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, J., E-mail: junping.zhao@qq.com; State Key Laboratory of Electrical Insulation and Power Equipment, West Xianning Road, Xi'an 710049; Department of Physics, SUPA, University of Strathclyde, Glasgow, G4 0NG Scotland

    Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gapmore » separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation.« less

  3. An experimental design for total container impact response modeling at extreme temperatures

    NASA Technical Reports Server (NTRS)

    Kobler, V. P.; Wyskida, R. M.; Johannes, J. D.

    1979-01-01

    An experimental design (a drop test) was developed to test the effects of confinement upon cushions. The drop test produced consistent corner void cushion data from which mathematical models were developed. A mathematical relationship between temperature and drop height was found.

  4. Capillary forces exerted by liquid drops caught between crossed cylinders. A 3-D meniscus problem with free contact line

    NASA Technical Reports Server (NTRS)

    Patzek, T. W.; Scriven, L. E.

    1982-01-01

    The Young-Laplace equation is solved for three-dimensional menisci between crossed cylinders, with either the contact line fixed or the contact angle prescribed, by means of the Galerkin/finite element method. Shapes are computed, and with them the practically important quantities: drop volume, wetted area, capillary pressure force, surface tension force, and the total force exerted by the drop on each cylinder. The results show that total capillary force between cylinders increases with decreasing contact angle, i.e. with better wetting. Capillary force is also increases with decreasing drop volume, approaching an asymptotic limit. However, the wetted area on each cylinder decreases with decreasing drop volume, which raises the question of the optimum drop volume to strive for, when permanent bonding is sought from solidified liquid. For then the strength of the bond is likely to depend upon the area of contact, which is the wetted area when the bonding agent was introduced in liquid form.

  5. A novel technique to measure interface trap density in a GaAs MOS capacitor using time-varying magnetic fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choudhury, Aditya N. Roy, E-mail: aditya@physics.iisc.ernet.in; Venkataraman, V.

    Interface trap density (D{sub it}) in a GaAs metal-oxide-semiconductor (MOS) capacitor can be measured electrically by measuring its impedance, i.e. by exciting it with a small signal voltage source and measuring the resulting current through the circuit. We propose a new method of measuring D{sub it} where the MOS capacitor is subjected to a (time-varying) magnetic field instead, which produces an effect equivalent to a (time-varying) voltage drop across the sample. This happens because the electron chemical potential of GaAs changes with a change in an externally applied magnetic field (unlike that of the gate metal); this is not themore » voltage induced by Faraday’s law of electromagnetic induction. So, by measuring the current through the MOS, D{sub it} can be found similarly. Energy band diagrams and equivalent circuits of a MOS capacitor are drawn in the presence of a magnetic field, and analyzed. The way in which a magnetic field affects a MOS structure is shown to be fundamentally different compared to an electrical voltage source.« less

  6. Performance analysis of resistive switching devices based on BaTiO3 thin films

    NASA Astrophysics Data System (ADS)

    Samardzic, Natasa; Kojic, Tijana; Vukmirovic, Jelena; Tripkovic, Djordjije; Bajac, Branimir; Srdic, Vladimir; Stojanovic, Goran

    2016-03-01

    Resitive switching devices, memristors, have recenty attracted much attention due to promising performances and potential applications in the field of logic and memory devices. Here, we present thin film BaTiO3 based memristor fabricated using ink-jet printing technique. Active material is a single layer barium titanate film with thickness of ̴100 nm, sandwitched between metal electodes. Printing parameters were optimized aiming to achieve stable drop flow and uniform printed layer. Current-voltage characteristics show typical memristive behavior with pinched hysteresis loop crossed at the origin, with marked differences between High Resistive State (HRS) and Low Resistive State (LRS). Obtained resistive states are stable during numerous switching processes. The device also shows unipolar switching effect for negative voltage impulses. Variable voltage impulse amplitudes leads to the shifting of the energy levels of electode contacts resulting in changing of the overall current through the device. Structural charcterization have been performed using XRD analysis and SEM micrography. High-temperature current-voltage measurements combined with transport parameter analysis using Hall efect measurement system (HMS 3000) and Impedance Analyzer AC measurements allows deeper insigth into conduction mechanism of ferroelectric memristors.

  7. PSO Based PI Controller Design for a Solar Charger System

    PubMed Central

    Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng

    2013-01-01

    Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs). PMID:23766713

  8. PSO based PI controller design for a solar charger system.

    PubMed

    Yau, Her-Terng; Lin, Chih-Jer; Liang, Qin-Cheng

    2013-01-01

    Due to global energy crisis and severe environmental pollution, the photovoltaic (PV) system has become one of the most important renewable energy sources. Many previous studies on solar charger integrated system only focus on load charge control or switching Maximum Power Point Tracking (MPPT) and charge control modes. This study used two-stage system, which allows the overall portable solar energy charging system to implement MPPT and optimal charge control of Li-ion battery simultaneously. First, this study designs a DC/DC boost converter of solar power generation, which uses variable step size incremental conductance method (VSINC) to enable the solar cell to track the maximum power point at any time. The voltage was exported from the DC/DC boost converter to the DC/DC buck converter, so that the voltage dropped to proper voltage for charging the battery. The charging system uses constant current/constant voltage (CC/CV) method to charge the lithium battery. In order to obtain the optimum PI charge controller parameters, this study used intelligent algorithm to determine the optimum parameters. According to the simulation and experimental results, the control parameters resulted from PSO have better performance than genetic algorithms (GAs).

  9. Enhancement of AlGaN/GaN high-electron mobility transistor off-state drain breakdown voltage via backside proton irradiation

    NASA Astrophysics Data System (ADS)

    Ren, F.; Hwang, Y.-H.; Pearton, S. J.; Patrick, Erin; Law, Mark E.

    2015-03-01

    Proton irradiation from the backside of the samples were employed to enhance off-state drain breakdown voltage of AlGaN/GaN high electron mobility transistors (HEMTs) grown on Si substrates. Via holes were fabricated directly under the active area of the HEMTs by etching through the Si substrate for subsequent backside proton irradiation. By taking the advantage of the steep drop at the end of proton energy loss profile, the defects created by the proton irradiation from the backside of the sample could be precisely placed at specific locations inside the AlGaN/GaN HEMT structure. There were no degradation of drain current nor enhancement of off-state drain voltage breakdown voltage observed for the irradiated AlGaN/GaN HEMTs with the proton energy of 225 or 275 keV, for which the defects created by the proton irradiations were intentionally placed in the GaN buffer. HEMTs with defects placed in the 2 dimensional electron gas (2DEG) channel region and AlGaN barrier using 330 or 340 keV protons not only showed degradation of drain current, but also exhibited improvement of the off-state drain breakdown voltage. FLOODS TCAD finite-element simulations were performed to confirm the hypothesis of a virtual gate formed around the 2DEG region to reduce the peak electric field around the gate edges and increase the off-state drain breakdown voltage.

  10. Polarization-independent rapidly tunable optical add-drop multiplexer utilizing non-polarizing beam splitters in Ti:LiNbO3

    NASA Astrophysics Data System (ADS)

    Shin, Yong-Wook; Sung, Won Ju; Eknoyan, O.; Madsen, C. K.; Taylor, H. F.

    2012-04-01

    A polarization-independent four-port wavelength-tunable optical add drop multiplexer (OADM) that utilizes non-polarizing relaxed beam splitters has been analyzed and demonstrated in Ti:LiNbO3 at the 1530 nm wavelength regime. The design utilizes an asymmetric interferometer configuration with strain induced index grating for polarization coupling along its arms that are shifted in position relative to each other. Experimental results of the filter response agree with theoretical predictions. Electrooptic tuning over a range of 15.7 nm at a rate of 0.08 nm/V has been measured. A temporal response < 46 ns to a 20 V step change in tuning voltage has been demonstrated. Fiber-to-fiber insertion loss is ~ 6.5 dB.

  11. The effect of mining data k-means clustering toward students profile model drop out potential

    NASA Astrophysics Data System (ADS)

    Purba, Windania; Tamba, Saut; Saragih, Jepronel

    2018-04-01

    The high of student success and the low of student failure can reflect the quality of a college. One of the factors of fail students was drop out. To solve the problem, so mining data with K-means Clustering was applied. K-Means Clustering method would be implemented to clustering the drop out students potentially. Firstly the the result data would be clustering to get the information of all students condition. Based on the model taken was found that students who potentially drop out because of the unexciting students in learning, unsupported parents, diffident students and less of students behavior time. The result of process of K-Means Clustering could known that students who more potentially drop out were in Cluster 1 caused Credit Total System, Quality Total, and the lowest Grade Point Average (GPA) compared between cluster 2 and 3.

  12. Modeling of Gate Bias Modulation in Carbon Nanotube Field-Effect-Transistors

    NASA Technical Reports Server (NTRS)

    Yamada, Toshishige; Biegel, Bryan (Technical Monitor)

    2002-01-01

    The threshold voltages of a carbon nanotube (CNT) field-effect transistor (FET) are derived and compared with those of the metal oxide-semiconductor (MOS) FETs. The CNT channel is so thin that there is no voltage drop perpendicular to the gate electrode plane, which is the CNT diameter direction, and this makes the CNTFET characteristics quite different from those in MOSFETs. The relation between the voltage and the electrochemical potentials, and the mass action law for electrons and holes are examined in the context of CNTs, and it is shown that the familiar relations are still valid because of the macroscopic number of states available in the CNTs. This is in sharp contrast to the cases of quantum dots. Using these relations, we derive an inversion threshold voltage V(sub Ti) and an accumulation threshold voltage V(sub Ta) as a function of the Fermi level E(sub F) in the channel, where E(sub F) is a measure of channel doping. V(sub Ti) of the CNTFETs has a much stronger dependence than that of MOSFETs, while V(sub Ta)s of both CNTFETs and MOSFETs depend quite weakly on E(sub F) with the same functional form. This means the transition from normally-off mode to normally-on mode is much sharper in CNTFETs as the doping increases, and this property has to be taken into account in circuit design.

  13. AC electrified jets in a flow-focusing device: Jet length scaling

    PubMed Central

    García-Sánchez, Pablo; Alzaga-Gimeno, Javier; Baret, Jean-Christophe

    2016-01-01

    We use a microfluidic flow-focusing device with integrated electrodes for controlling the production of water-in-oil drops. In a previous work, we reported that very long jets can be formed upon application of AC fields. We now study in detail the appearance of the long jets as a function of the electrical parameters, i.e., water conductivity, signal frequency, and voltage amplitude. For intermediate frequencies, we find a threshold voltage above which the jet length rapidly increases. Interestingly, this abrupt transition vanishes for high frequencies of the signal and the jet length grows smoothly with voltage. For frequencies below a threshold value, we previously reported a transition from a well-behaved uniform jet to highly unstable liquid structures in which axisymmetry is lost rather abruptly. These liquid filaments eventually break into droplets of different sizes. In this work, we characterize this transition with a diagram as a function of voltage and liquid conductivity. The electrical response of the long jets was studied via a distributed element circuit model. The model allows us to estimate the electric potential at the tip of the jet revealing that, for any combination of the electrical parameters, the breakup of the jet occurs at a critical value of this potential. We show that this voltage is around 550 V for our device geometry and choice of flow rates. PMID:27375826

  14. AC electrified jets in a flow-focusing device: Jet length scaling.

    PubMed

    Castro-Hernández, Elena; García-Sánchez, Pablo; Alzaga-Gimeno, Javier; Tan, Say Hwa; Baret, Jean-Christophe; Ramos, Antonio

    2016-07-01

    We use a microfluidic flow-focusing device with integrated electrodes for controlling the production of water-in-oil drops. In a previous work, we reported that very long jets can be formed upon application of AC fields. We now study in detail the appearance of the long jets as a function of the electrical parameters, i.e., water conductivity, signal frequency, and voltage amplitude. For intermediate frequencies, we find a threshold voltage above which the jet length rapidly increases. Interestingly, this abrupt transition vanishes for high frequencies of the signal and the jet length grows smoothly with voltage. For frequencies below a threshold value, we previously reported a transition from a well-behaved uniform jet to highly unstable liquid structures in which axisymmetry is lost rather abruptly. These liquid filaments eventually break into droplets of different sizes. In this work, we characterize this transition with a diagram as a function of voltage and liquid conductivity. The electrical response of the long jets was studied via a distributed element circuit model. The model allows us to estimate the electric potential at the tip of the jet revealing that, for any combination of the electrical parameters, the breakup of the jet occurs at a critical value of this potential. We show that this voltage is around 550 V for our device geometry and choice of flow rates.

  15. Mitigation of commutation failures in LCC-HVDC systems based on superconducting fault current limiters

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Geon; Khan, Umer Amir; Lee, Ho-Yun; Lim, Sung-Woo; Lee, Bang-Wook

    2016-11-01

    Commutation failure in line commutated converter based HVDC systems cause severe damages on the entire power grid system. For LCC-HVDC, thyristor valves are turned on by a firing signal but turn off control is governed by the external applied AC voltage from surrounding network. When the fault occurs in AC system, turn-off control of thyristor valves is unavailable due to the voltage collapse of point of common coupling (PCC), which causes the commutation failure in LCC-HVDC link. Due to the commutation failure, the power transfer interruption, dc voltage drop and severe voltage fluctuation in the AC system could be occurred. In a severe situation, it might cause the protection system to block the valves. In this paper, as a solution to prevent the voltage collapse on PCC and to limit the fault current, the application study of resistive superconducting fault current limiter (SFCL) on LCC-HVDC grid system was performed with mathematical and simulation analyses. The simulation model was designed by Matlab/Simulink considering Haenam-Jeju HVDC power grid in Korea which includes conventional AC system and onshore wind farm and resistive SFCL model. From the result, it was observed that the application of SFCL on LCC-HVDC system is an effective solution to mitigate the commutation failure. And then the process to determine optimum quench resistance of SFCL which enables the recovery of commutation failure was deeply investigated.

  16. Analysis of Drop Shapes during Electrowetting on a Dielectric

    NASA Astrophysics Data System (ADS)

    Daneshbod, Yousef

    2005-03-01

    Electrowetting refers to the electrostatic control of the interfacial energy of a liquid on a solid, primarily used for the transport of micro-liter volumes of drops on surfaces with embedded electrode arrays. In the present work, the drop is modeled as a two-dimensional lens-like conductor immersed in an infinite dielectric medium slightly above a planar conductor. A matched asymptotic expansion is used to approximate the electrostatic field surrounding the drop. The outer problem models the drop as a conducting circular segment resting on the conducting plane, each maintained at a separate constant potential. The inner problem corrects the region near the edge of the drop by modeling it as an infinite planar conducting wedge lying slightly above the conducting plane. By matching the inner and outer solutions, the charge density along the entire surface of the drop can be approximated, enabling the calculation of the total capacitance of the system. An energy minimization method similar to that of Shapiro et al. [J. Appl. Phys., 93, 5794 (2003)] is applied to the total energy consisting of the liquid/gas, liquid/solid and solid/gas surface energies, together with the electrostatic contribution, subject to the constraint that the drop volume remains constant. A modified form of the Young-Lippmann equation is thus derived that includes the contribution from the extra capacitance of the drop obtained via matched asymptotics.

  17. Alternating gradient photodetector

    NASA Technical Reports Server (NTRS)

    Overhauser, Albert W. (Inventor); Maserjian, Joseph (Inventor)

    1989-01-01

    A far infrared (FIR) range responsive photodetector is disclosed. There is a substrate of degenerate germanium. A plurality of alternating impurity-band and high resistivity layers of germanium are disposed on the substrate. The impurity-band layers have a doping concentration therein sufficiently high to include donor bands which can release electrons upon impingement by FIR photons of energy hv greater than an energy gap epsilon. The high resistivity layers have a doping concentration therein sufficiently low as to not include conducting donor bands and are depleted of electrons. Metal contacts are provided for applying an electrical field across the substrate and the plurality of layers. In the preferred embodiment as shown, the substrate is degenerate n-type (N++) germanium; the impurity-band layers are n+ layers of germanium doped to approximately the low 10(exp 16)/cu cm range; and, the high resistivity layers are n-layers of germanium doped to a maximum of approximately 10(exp)/cu cm. Additionally, the impurity-band layers have a thickness less than a conduction-electron diffusion length in germanium and likely to be in the range of 0.1 to 1.0 micron, the plurality of impurity-bands is of a number such that the flux of FIR photons passing therethrough will be substantially totally absorbed therein, the thickness of the high resistivity layers is such compared to the voltage applied that the voltage drop in each the high resistivity layers controls the occurence of impact ionization in the impurity-band layers to a desired level.

  18. The electrical asymmetry effect in a multi frequency geometrically asymmetric capacitively coupled plasma: A study by a nonlinear global model

    NASA Astrophysics Data System (ADS)

    Saikia, P.; Bhuyan, H.; Escalona, M.; Favre, M.; Bora, B.; Kakati, M.; Wyndham, E.; Rawat, R. S.; Schulze, J.

    2018-05-01

    We investigate the electrical asymmetry effect (EAE) and the current dynamics in a geometrically asymmetric capacitively coupled radio frequency plasma driven by multiple consecutive harmonics based on a nonlinear global model. The discharge symmetry is controlled via the EAE, i.e., by varying the total number of harmonics and tuning the phase shifts ( θ k ) between them. Here, we systematically study the EAE in a low pressure (4 Pa) argon discharge with different geometrical asymmetries driven by a multifrequency rf source consisting of 13.56 MHz and its harmonics. We find that the geometrical asymmetry strongly affects the absolute value of the DC self-bias voltage, but its functional dependence on θ k is similar at different values of the geometrical asymmetry. Also, the values of the DC self-bias are enhanced by adding more consecutive harmonics. The voltage drop across the sheath at the powered and grounded electrode is found to increase/decrease, respectively, with the increase in the number of harmonics of the fundamental frequency. For the purpose of validating the model, its outputs are compared with the results obtained in a geometrically and electrically asymmetric 2f capacitively coupled plasmas experiment conducted by Schuengel et al. [J. Appl. Phys. 112, 053302 (2012)]. Finally, we study the self-excitation of nonlinear plasma series resonance oscillations and its dependence on the geometrical asymmetry as well as the phase angles between the driving frequencies.

  19. Applied Physics Research for Innovation in Pulsed Power

    DTIC Science & Technology

    1994-09-30

    yet li.... hilh I"*~ OWLC Figeue of (r-esoh gad) worik So e 0o0 baeer i*s es..esem or": Lane. bndgs, low N bu ilk ,, ly e w a, ver h voka" Oiemoed...4)~~ ~ 2WV"tW ~ electron drift mobility C) 2 V 3 FurLow forward voltage drop and 4) CO V OA. PEfT fast switching speed In majority carriler devices t

  20. Relativistic Magnetron Priming Experiments and Theory

    DTIC Science & Technology

    2010-03-29

    rest mass and charge of an electron, respectively, c is the speed of light, and V is the voltage drop across the anode-cathode gap. D is the effective ...and Verboncoeur1 as an effect generated by a multipactor model that also requires a seed electron to initiate the process. The existence of a seed...Discovery of unexpected effects of ions in magnetically insulated crossed-field gap. 2) Buneman-Hartree condition was critically re-examined in a

  1. SPECIFIC HEAT INDICATOR

    DOEpatents

    Horn, F.L.; Binns, J.E.

    1961-05-01

    Apparatus for continuously and automatically measuring and computing the specific heat of a flowing solution is described. The invention provides for the continuous measurement of all the parameters required for the mathematical solution of this characteristic. The parameters are converted to logarithmic functions which are added and subtracted in accordance with the solution and a null-seeking servo reduces errors due to changing voltage drops to a minimum. Logarithmic potentiometers are utilized in a unique manner to accomplish these results.

  2. A ballistic two-dimensional-electron-gas Andreev interferometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amado, M., E-mail: mario.amadomontero@sns.it; Fornieri, A.; Sorba, L.

    2014-06-16

    We report the realization and investigation of a ballistic Andreev interferometer based on an InAs two dimensional electron gas coupled to a superconducting Nb loop. We observe strong magnetic modulations in the voltage drop across the device due to quasiparticle interference within the weak-link. The interferometer exhibits flux noise down to ∼80 μΦ{sub 0}/√(Hz) and a robust behavior in temperature with voltage oscillations surviving up to ∼7 K. Besides this remarkable performance, the device represents a crucial first step for the realization of a fully-tunable ballistic superconducting magnetometer and embodies a potential advanced platform for the investigation of Majorana bound states, non-localmore » entanglement of Cooper pairs, as well as the manipulation and control of spin triplet correlations.« less

  3. Preparation and characterization of electrodes for the NASA Redox storage system

    NASA Technical Reports Server (NTRS)

    Reid, M. A.; Gahn, R. F.; Ling, J. S.; Charleston, J.

    1980-01-01

    Electrodes for the Redox energy storage system based on iron and chromium chloride reactants is discussed. The physical properties of several lots of felt were determined. Procedures were developed for evaluating electrode performance in lab scale cells. Experimental procedures for evaluating electrodes by cyclic voltammetry are described which minimize the IR losses due to the high internal resistance in the felt (distributed resistance). Methods to prepare electrodes which reduced the coevolution of hydrogen at the chromium electrode and eleminate the drop in voltage on discharge occasionally seen with previous electrodes were discussed. Single cells of 0.3329 ft area with improved membranes and electrodes are operating at over 80% voltage efficiency and coulombic efficiencies of over 98% at current densities of 16 to 20 amp % ft.

  4. Voltage-gated K+ channel modulators as neuroprotective agents.

    PubMed

    Leung, Yuk-Man

    2010-05-22

    A manifestation in neurodegeneration is apoptosis of neurons. Neurons undergoing apoptosis may lose a substantial amount of cytosolic K+ through a number of pathways including K+ efflux via voltage-gated K+ (Kv) channels. The consequent drop in cytosolic [K+] relieves inhibition of an array of pro-apoptotic enzymes such as caspases and nucleases. Blocking Kv channels has been known to prevent neuronal apoptosis by preventing K+ efflux. Some neural diseases such as epilepsy are caused by neuronal hyperexcitability, which eventually may lead to neuronal apoptosis. Reduction in activities of A-type Kv channels and Kv7 subfamily members is amongst the etiological causes of neuronal hyperexcitation; enhancing the opening of these channels may offer opportunities of remedy. This review discusses the potential uses of Kv channel modulators as neuroprotective drugs.

  5. Determination of appropriate DC voltage for switched mode power supply (SMPS) loads

    NASA Astrophysics Data System (ADS)

    Setiawan, Eko Adhi; Setiawan, Aiman; Purnomo, Andri; Djamal, Muchlishah Hadi

    2017-03-01

    Nowadays, most of modern and efficient household electronic devices operated based on Switched Mode Power Supply (SMPS) technology which convert AC voltage from the grid to DC voltage. Based on theory and experiment, SMPS loads could be supplied by DC voltage. However, the DC voltage rating to energize electronic home appliances is not standardized yet. This paper proposed certain method to determine appropriate DC voltage, and investigated comparison of SMPS power consumption which is supplied from AC and DC voltage. To determine the appropriate DC voltage, lux value of several lamps which have same specification energized by using AC voltage and the results is using as reference. Then, the lamps were supplied by various DC voltage to obtain the trends of the lux value to the applied DC voltage. After that, by using the trends and the reference lux value, the appropriate DC voltage can be determined. Furthermore, the power consumption on home appliances such as mobile phone, laptop and personal computer by using AC voltage and the appropriate DC voltage were conducted. The results show that the total power consumption of AC system is higher than DC system. The total power (apparent power) consumed by the lamp, mobile phone and personal computer which operated in 220 VAC were 6.93 VA, 34.31 VA and 105.85 VA respectively. On the other hand, under 277 VDC the load consumption were 5.83 W, 19.11 W and 74.46 W respectively.

  6. Ultra-low power high temperature and radiation hard complementary metal-oxide-semiconductor (CMOS) silicon-on-insulator (SOI) voltage reference.

    PubMed

    Boufouss, El Hafed; Francis, Laurent A; Kilchytska, Valeriya; Gérard, Pierre; Simon, Pascal; Flandre, Denis

    2013-12-13

    This paper presents an ultra-low power CMOS voltage reference circuit which is robust under biomedical extreme conditions, such as high temperature and high total ionized dose (TID) radiation. To achieve such performances, the voltage reference is designed in a suitable 130 nm Silicon-on-Insulator (SOI) industrial technology and is optimized to work in the subthreshold regime of the transistors. The design simulations have been performed over the temperature range of -40-200 °C and for different process corners. Robustness to radiation was simulated using custom model parameters including TID effects, such as mobilities and threshold voltages degradation. The proposed circuit has been tested up to high total radiation dose, i.e., 1 Mrad (Si) performed at three different temperatures (room temperature, 100 °C and 200 °C). The maximum drift of the reference voltage V(REF) depends on the considered temperature and on radiation dose; however, it remains lower than 10% of the mean value of 1.5 V. The typical power dissipation at 2.5 V supply voltage is about 20 μW at room temperature and only 75 μW at a high temperature of 200 °C. To understand the effects caused by the combination of high total ionizing dose and temperature on such voltage reference, the threshold voltages of the used SOI MOSFETs were extracted under different conditions. The evolution of V(REF) and power consumption with temperature and radiation dose can then be explained in terms of the different balance between fixed oxide charge and interface states build-up. The total occupied area including pad-ring is less than 0.09 mm2.

  7. Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion.

    PubMed

    Kojima, A; Hanada, M; Tobari, H; Nishikiori, R; Hiratsuka, J; Kashiwagi, M; Umeda, N; Yoshida, M; Ichikawa, M; Watanabe, K; Yamano, Y; Grisham, L R

    2016-02-01

    Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltage holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.

  8. Nonlinear oscillations of inviscid free drops

    NASA Technical Reports Server (NTRS)

    Patzek, T. W.; Benner, R. E., Jr.; Basaran, O. A.; Scriven, L. E.

    1991-01-01

    The present analysis of free liquid drops' inviscid oscillations proceeds through solution of Bernoulli's equation to obtain the free surface shape and of Laplace's equation for the velocity potential field. Results thus obtained encompass drop-shape sequences, pressure distributions, particle paths, and the temporal evolution of kinetic and surface energies; accuracy is verified by the near-constant drop volume and total energy, as well as the diminutiveness of mass and momentum fluxes across drop surfaces. Further insight into the nature of oscillations is provided by Fourier power spectrum analyses of mode interactions and frequency shifts.

  9. Performance of air-cathode stacked microbial fuel cells systems for wastewater treatment and electricity production.

    PubMed

    Estrada-Arriaga, Edson Baltazar; Guillen-Alonso, Yvonne; Morales-Morales, Cornelio; García-Sánchez, Liliana; Bahena-Bahena, Erick Obed; Guadarrama-Pérez, Oscar; Loyola-Morales, Félix

    2017-07-01

    Two different air-cathode stacked microbial fuel cell (MFC) configurations were evaluated under continuous flow during the treatment of municipal wastewater and electricity production at a hydraulic retention time (HRT) of 3, 1, and 0.5 d. Stacked MFC 1 was formed by 20 individual air-cathode MFC units. The second stacked MFC (stacked MFC 2) consisted of 40 air-cathode MFC units placed in a shared reactor. The maximum voltages produced at closed circuit (1,000 Ω) were 170 mV for stacked MFC 1 and 94 mV for stacked MFC 2. Different power densities in each MFC unit were obtained due to a potential drop phenomenon and to a change in chemical oxygen demand (COD) concentrations inside reactors. The maximum power densities from individual MFC units were up to 1,107 mW/m 2 for stacked MFC 1 and up to 472 mW/m 2 for stacked MFC 2. The maximum power densities in stacked MFC 1 and MFC 2 connected in series were 79 mW/m 2 and 4 mW/m 2 , respectively. Electricity generation and COD removal efficiencies were reduced when the HRT was decreased. High removal efficiencies of 84% of COD, 47% of total nitrogen, and 30% of total phosphorus were obtained during municipal wastewater treatment.

  10. Performance of a low cost interdigitated flow design on a 1 kW class all vanadium mixed acid redox flow battery

    NASA Astrophysics Data System (ADS)

    Reed, David; Thomsen, Edwin; Li, Bin; Wang, Wei; Nie, Zimin; Koeppel, Brian; Sprenkle, Vincent

    2016-02-01

    Three flow designs were operated in a 3-cell 1 kW class all vanadium mixed acid redox flow battery. The influence of electrode surface area and flow rate on the coulombic, voltage, and energy efficiency and the pressure drop in the flow circuit will be discussed and correlated to the flow design. Material cost associated with each flow design will also be discussed.

  11. Geophysical Investigation at Gathright Dam.

    DTIC Science & Technology

    1982-03-01

    a limestone, is actually a calcareous and dolomitic siltstone. The siltstone is thin-bedded and in areas al- most fissile. The jointing of the...voltage across the Helmholtz double layer (laminar flow con- dition in a capillary tube) n = viscosity of the pore fluid AP = pressure drop along...spring RB-2 only. c. In RS-3, the fractured and clayey zone at el 1370 pro- duced muddy flow in the river spring. d. Core boring RS-4 caused muddy flow in

  12. Fuel cell development for transportation: Catalyst development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doddapaneni, N.

    1996-04-01

    Fuel cells are being considered as alternate power sources for transportation and stationary applications. With proton exchange membrane (PEM) fuel cells the fuel crossover to cathodes causes severe thermal management and cell voltage drop due to oxidation of fuel at the platinized cathodes. The main goal of this project was to design, synthesize, and evaluate stable and inexpensive transition metal macrocyclic catalysts for the reduction of oxygen and be electrochemically inert towards anode fuels such as hydrogen and methanol.

  13. Current Flow and Pair Creation at Low Altitude in Rotation-Powered Pulsars' Force-Free Magnetospheres: Space Charge Limited Flow

    NASA Technical Reports Server (NTRS)

    Timokhin, A. N.; Arons, J.

    2013-01-01

    We report the results of an investigation of particle acceleration and electron-positron plasma generation at low altitude in the polar magnetic flux tubes of rotation-powered pulsars, when the stellar surface is free to emit whatever charges and currents are demanded by the force-free magnetosphere. We apply a new 1D hybrid plasma simulation code to the dynamical problem, using Particle-in-Cell methods for the dynamics of the charged particles, including a determination of the collective electrostatic fluctuations in the plasma, combined with a Monte Carlo treatment of the high-energy gamma-rays that mediate the formation of the electron-positron pairs.We assume the electric current flowing through the pair creation zone is fixed by the much higher inductance magnetosphere, and adopt the results of force-free magnetosphere models to provide the currents which must be carried by the accelerator. The models are spatially one dimensional, and designed to explore the physics, although of practical relevance to young, high-voltage pulsars. We observe novel behaviour (a) When the current density j is less than the Goldreich-Julian value (0 < j/j(sub GJ) < 1), space charge limited acceleration of the current carrying beam is mild, with the full Goldreich-Julian charge density comprising the charge densities of the beam and a cloud of electrically trapped particles with the same sign of charge as the beam. The voltage drops are of the order of mc(sup 2)/e, and pair creation is absent. (b) When the current density exceeds the Goldreich-Julian value (j/j(sub GJ) > 1), the system develops high voltage drops (TV or greater), causing emission of curvature gamma-rays and intense bursts of pair creation. The bursts exhibit limit cycle behaviour, with characteristic time-scales somewhat longer than the relativistic fly-by time over distances comparable to the polar cap diameter (microseconds). (c) In return current regions, where j/j(sub GJ) < 0, the system develops similar bursts of pair creation. These discharges are similar to those encountered in previous calculations by Timokhin of pair creation when the surface has a high work function and cannot freely emit charge. In cases (b) and (c), the intermittently generated pairs allow the system to simultaneously carry the magnetospherically prescribed currents and adjust the charge density and average electric field to force-free conditions. We also elucidate the conditions for pair creating beam flow to be steady (stationary with small fluctuations in the rotating frame), finding that such steady flows can occupy only a small fraction of the current density parameter space exhibited by the force-free magnetospheric model. The generic polar flow dynamics and pair creation are strongly time dependent. The model has an essential difference from almost all previous quantitative studies, in that we sought the accelerating voltage (with pair creation, when the voltage drops are sufficiently large; without, when they are small) as a function of the applied current.

  14. Southern pulpwood production, 1975

    Treesearch

    Thomas R. Bellamy

    1976-01-01

    Southern pulpwood production in 1975 dropped a record 14 percent from the previous year. A 16-percent drop in roundwood accounted for over 80 percent of the total decline. Usable wood residues dropped 9 percent, primarily from hardwoods. Of the 42.3 million cords produced, 30 million were roundwood and 12 million were residues. Pulping capacity for the region increased...

  15. Junction barrier Schottky rectifier with an improved P-well region

    NASA Astrophysics Data System (ADS)

    Wang, Ying; Li, Ting; Cao, Fei; Shao, Lei; Chen, Yu-Xian

    2012-12-01

    A junction barrier Schottky (JBS) rectifier with an improved P-well on 4H—SiC is proposed to improve the VF—IR trade-off and the breakdown voltage. The reverse current density of the proposed JBS rectifier at 300 K and 800 V is about 3.3×10-8 times that of the common JBS rectifier at no expense of the forward voltage drop. This is because the depletion layer thickness in the P-well region at the same reverse voltage is larger than in the P+ grid, resulting in a lower spreading current and tunneling current. As a result, the breakdown voltage of the proposed JBS rectifier is over 1.6 kV, that is about 0.8 times more than that of the common JBS rectifier due to the uniform electric field. Although the series resistance of the proposed JBS rectifier is a little larger than that of the common JBS rectifier, the figure of merit (FOM) of the proposed JBS rectifier is about 2.9 times that of the common JBS rectifier. Based on simulating the values of susceptibility of the two JBS rectifiers to electrostatic discharge (ESD) in the human body model (HBM) circuits, the failure energy of the proposed JBS rectifier increases 17% compared with that of the common JBS rectifier.

  16. Development of Vibration-Based Piezoelectric Raindrop Energy Harvesting System

    NASA Astrophysics Data System (ADS)

    Wong, Chin Hong; Dahari, Zuraini

    2017-03-01

    The trend of finding new means to harvest energy has triggered numerous researches to explore the potential of raindrop energy harvesting. This paper presents an investigation on raindrop energy harvesting which compares the performance of polyvinylidene fluoride (PVDF) cantilever and bridge structure transducers and the development of a raindrop energy harvesting system. The parameters which contribute to the output voltage such as droplet size, droplets released at specific heights and dimensions of PVDF transducers are analyzed. Based on the experimental results, the outcomes have shown that the bridge structure transducer generated a higher voltage than the cantilever. Several dimensions have been tested and it was found that the 30 mm × 4 mm × 25 μm bridge structure transducer generated a relatively high AC open-circuit voltage, which is 4.22 V. The power generated by the bridge transducer is 18 μW across a load of 330 kΩ. The transducer is able to drive up a standard alternative current (AC) to direct current (DC) converter (full-wave bridge rectifier). It generated a DC voltage, V DC of 8.7 mV and 229 pW across a 330 kΩ resistor per drop. It is also capable to generate 9.3 nJ in 20 s from an actual rain event.

  17. 2D particle-in-cell simulation of the entire process of surface flashover on insulator in vacuum

    NASA Astrophysics Data System (ADS)

    Wang, Hongguang; Zhang, Jianwei; Li, Yongdong; Lin, Shu; Zhong, Pengfeng; Liu, Chunliang

    2018-04-01

    With the introduction of an external circuit model and a gas desorption model, the surface flashover on the plane insulator-vacuum interface perpendicular to parallel electrodes is simulated by a Particle-In-Cell method. It can be seen from simulations that when the secondary electron emission avalanche (SEEA) occurs, the current sharply increases because of the influence of the insulator surface charge on the cathode field emission. With the introduction of the gas desorption model, the current keeps on increasing after SEEA, and then the feedback of the external circuit causes the voltage between the two electrodes to decrease. The cathode emission current decreases, while the anode current keeps growing. With the definition that flashover occurs when the diode voltage drops by more than 20%, we obtained the simulated flashover voltage which agrees with the experimental value with the use of the field enhancement factor β = 145 and the gas molecule desorption coefficient γ=0.25 . From the simulation results, we can also see that the time delay of flashover decreases exponentially with voltage. In addition, from the gas desorption model, the gas density on the insulator surface is found to be proportional to the square of the gas desorption rate and linear with time.

  18. A prepositioned areal electrofishing apparatus for sampling stream habitats

    USGS Publications Warehouse

    Fisher, William L.; Brown, Marshall E.

    1993-01-01

    We describe the design, use, and sampling characteristics ofan electrofishing apparatus used to sample fish in stream habitats. The apparatus uses two prepositioned areal electrofishing devices (PAED) of different designs, a bottom parallel electrode PAED and a suspended dropper electrode PAED. To determine the effective immobilization ranges of the PAEDs, we evaluated intensities and shapes of the PAEDs' electrical fields, and the electroshock responses of fish in cages in concrete tanks and in four streams in Alabama with different water conductivities. Electroshock responses indicated that complete immobilization occurred at voltage gradients of 1.0 V/cm or higher (voltage drop, 400 V AC), as far as 35 cm from the PAED electrodes, although some fish were immobilized up to 65 cm away at 0.3 V/cm. We estimated the immobilization (stun) power density threshold to be about 10 μW/cm3. Stream evaluations of the PAEDs revealed that higher voltages were needed to immobilize fish at lower (35 μS/cm) and higher (120 and 125 μS/cm) water conductivities, whereas lower voltages were required at an intermediate conductivity (60 μS/cm). These results conformed with the predictions of power transfer theory and underscored the need to calibrate PAEDs to stream conductivities to standardize the effective sampling range.

  19. In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part II: Operational applications

    NASA Astrophysics Data System (ADS)

    Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik

    2016-08-01

    This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.

  20. Effect of secondary electron emission on subnanosecond breakdown in high-voltage pulse discharge

    NASA Astrophysics Data System (ADS)

    Schweigert, I. V.; Alexandrov, A. L.; Gugin, P.; Lavrukhin, M.; Bokhan, P. A.; Zakrevsky, Dm E.

    2017-11-01

    The subnanosecond breakdown in open discharge may be applied for producing superfast high power switches. Such fast breakdown in high-voltage pulse discharge in helium was explored both in experiment and in kinetic simulations. The kinetic model of electron avalanche development was developed using PIC-MCC technique. The model simulates motion of electrons, ions and fast helium atoms, appearing due to ions scattering. It was shown that the mechanism responsible for ultra-fast breakdown development is the electron emission from cathode. The photoemission and emission by ions or fast atoms impact is the main reason of current growth at the early stage of breakdown, but at the final stage, when the voltage on discharge gap drops, the secondary electron emission (SEE) is responsible for subnanosecond time scale of current growth. It was also found that the characteristic time of the current growth τS depends on the SEE yield of the cathode material. Three types of cathode material (titanium, SiC, and CuAlMg-alloy) were tested. It is shown that in discharge with SiC and CuAlMg-alloy cathodes (which have enhanced SEE) the current can increase with a subnanosecond characteristic time as small as τS = 0.4 ns, for the pulse voltage amplitude of 5- 12 kV..

  1. Magnetopause reconnection rate estimates for Jupiter's magnetosphere based on interplanetary measurements at ~5AU

    NASA Astrophysics Data System (ADS)

    Nichols, J. D.; Cowley, S. W. H.; McComas, D. J.

    2006-03-01

    We make the first quantitative estimates of the magnetopause reconnection rate at Jupiter using extended in situ data sets, building on simple order of magnitude estimates made some thirty years ago by Brice and Ionannidis (1970) and Kennel and Coroniti (1975, 1977). The jovian low-latitude magnetopause (open flux production) reconnection voltage is estimated using the Jackman et al. (2004) algorithm, validated at Earth, previously applied to Saturn, and here adapted to Jupiter. The high-latitude (lobe) magnetopause reconnection voltage is similarly calculated using the related Gérard et al. (2005) algorithm, also previously used for Saturn. We employ data from the Ulysses spacecraft obtained during periods when it was located near 5AU and within 5° of the ecliptic plane (January to June 1992, January to August 1998, and April to October 2004), along with data from the Cassini spacecraft obtained during the Jupiter flyby in 2000/2001. We include the effect of magnetospheric compression through dynamic pressure modulation, and also examine the effect of variations in the direction of Jupiter's magnetic axis throughout the jovian day and year. The intervals of data considered represent different phases in the solar cycle, such that we are also able to examine solar cycle dependency. The overall average low-latitude reconnection voltage is estimated to be ~230 kV, such that the average amount of open flux created over one solar rotation is ~500 GWb. We thus estimate the average time to replenish Jupiter's magnetotail, which contains ~300-500 GWb of open flux, to be ~15-25 days, corresponding to a tail length of ~3.8-6.5 AU. The average high-latitude reconnection voltage is estimated to be ~130 kV, associated with lobe "stirring". Within these averages, however, the estimated voltages undergo considerable variation. Generally, the low-latitude reconnection voltage exhibits a "background" of ~100 kV that is punctuated by one or two significant enhancement events during each solar rotation, in which the voltage is elevated to ~1-3 MV. The high-latitude voltages are estimated to be about a half of these values. We note that the peak values of order a few MV are comparable to the potential drop due to sub-corotating plasma flows in the equatorial magnetosphere between ~20 RJ and the magnetopause, such that during these periods magnetopause reconnection may have a significant effect on the otherwise rotationally dominated magnetosphere. Despite such variations during each solar rotation, however, the total amount of open flux produced during each solar rotation varies typically by less than ~30% on either side of the overall average for that epoch. The averages over individual data epochs vary over the solar cycle from ~600 GWb per solar rotation at solar maximum to ~400 GWb at solar minimum. In addition we show that the IMF sector with positive clock angle is favoured for reconnection when the jovian spin axis clock angle is also positive, and vice versa, although this effect represents a first order correction to the voltage, which is primarily modulated by IMF strength and direction.

  2. Effect of La3+ substitution with Gd3+ on the resistive switching properties of La0.7Sr0.3MnO3 thin films

    NASA Astrophysics Data System (ADS)

    Lee, Hong-Sub; Park, Chang-Sun; Park, Hyung-Ho

    2014-05-01

    This study demonstrated that the resistive switching voltage of perovskite manganite material could be controlled by A-site cation substitution in "A" MnO3 perovskite manganite structure. A partial substitution of La3+ in La0.7Sr0.3MnO3 with smaller cation Gd3+ induced A-site vacancy of the largest Sr2+ cation with surface segregation of SrOy due to ionic size mismatch, and the induced vacancies reduced migration energy barrier. The operating voltage decreased from 3.5 V to 2.5 V due to a favorable condition for electrochemical migration and redox of oxygen ions. Moreover, surface-segregated SrOy was enhanced with Gd-substitution and the SrOy reduced Schottky-like barrier height and resistive switching ratio from the potential drop and screening effect. The relationship between A-site vacancy generation resulting in surface segregation of SrOy and resistive switching behavior was also investigated by energy resolved x-ray photoelectron spectroscopy, O 1s near edge x-ray absorption spectroscopy, and current voltage measurement.

  3. A novel method for identification of lithium-ion battery equivalent circuit model parameters considering electrochemical properties

    NASA Astrophysics Data System (ADS)

    Zhang, Xi; Lu, Jinling; Yuan, Shifei; Yang, Jun; Zhou, Xuan

    2017-03-01

    This paper proposes a novel parameter identification method for the lithium-ion (Li-ion) battery equivalent circuit model (ECM) considering the electrochemical properties. An improved pseudo two-dimension (P2D) model is established on basis of partial differential equations (PDEs), since the electrolyte potential is simplified from the nonlinear to linear expression while terminal voltage can be divided into the electrolyte potential, open circuit voltage (OCV), overpotential of electrodes, internal resistance drop, and so on. The model order reduction process is implemented by the simplification of the PDEs using the Laplace transform, inverse Laplace transform, Pade approximation, etc. A unified second order transfer function between cell voltage and current is obtained for the comparability with that of ECM. The final objective is to obtain the relationship between the ECM resistances/capacitances and electrochemical parameters such that in various conditions, ECM precision could be improved regarding integration of battery interior properties for further applications, e.g., SOC estimation. Finally simulation and experimental results prove the correctness and validity of the proposed methodology.

  4. Anomalous Current-Voltage Characteristics in Suspended Carbon Nanotubes in Various Gas Environments

    NASA Astrophysics Data System (ADS)

    Amer, Moh; Bushmaker, Adam; Cronin, Steve

    2011-03-01

    Electrically-heated suspended, carbon nanotubes (CNTs) exhibiting negative differential conductance in the high bias regime experience a sudden drop in current (or ``kink'') in various gaseous environments. We study the effect of different gas molecules on these I - V characteristics while simultaneously monitoring the changes in the nanotube vibrational structure under high bias voltages using Raman spectroscopy. When the nanotube is electrically biased at the kink, the G band Raman mode is observed to downshift, as is typical of electrically heated devices. However, the G band frequency at the kink (ωGkink) lies in the narrow range between 1575 and 1579 cm-1 for all samples measured, regardless of gas environment. The voltage at which the kink occurs depends on the type of the gas environment with the following dependence: VkinkAr

  5. Ion extraction capabilities of two-grid accelerator systems. [for spacecraft propulsion

    NASA Technical Reports Server (NTRS)

    Rovang, D. C.; Wilbur, P. J.

    1984-01-01

    An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. A large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current is presented. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high.

  6. A Thermoelectric Energy Harvesting System for Powering Wireless Sensors in Nuclear Power Plants

    NASA Astrophysics Data System (ADS)

    Chen, Jie; Klein, Jackson; Wu, Yongjia; Xing, Shaoxu; Flammang, Robert; Heibel, Michael; Zuo, Lei

    2016-10-01

    Safety is the most important issue in the development of nuclear energy. This paper reports experimental studies of a thermoelectric energy harvesting system designed for integration in a nuclear power plant capable of performing in radiation rich environments and producing enough power to run wireless sensors meant to increase plant safety. Furthermore, the system, which utilizes wasted heat present in coolant system piping, has the unique ability to provide power in both normal and accidental situations, to run the sensors without the need for external power. Two energy harvesting prototypes were designed utilizing a heat pipe for heat transfer. The first can supply a maximum power of 2.25 W using two Bi2Te3 thermoelectric modules of 2.79cm (1.1") × 2.79 cm (1.1”), in a source temperature near 250 °C. A second design was put forward to extend the application in higher-temperature primary loops, in which one PbTe-Bi2Te3 hybrid TEG module of 5.6cm (2.2") × 5.6 cm (2.2") can provide a power of 3.0 W when the hot side temperature reaches 340 °C. In addition to the energy harvester, wireless communication circuits were developed along with an integrated power management circuit for wireless data transmission. A high intensity gamma radiation experiment was conducted during which each component was irradiated. A total dose of 200 kGy±10% (20M rads) was applied to the first prototype in order to approximate the expected lifetime accumulation for one implemented thermoelectric generator. Results showed that thermoelectric modules used in the prototype had no reduction in voltage output throughout irradiation. Throughout the experiment the harvester system witnessed a small voltage drop in open circuit voltage attributed to a reduction in heat pipe performance from radiation exposure. We also acquired a baseline radiation survivability level for non-hardened, non-shielded electronics of 102 Gy.

  7. The effect of surface conditions on the work function of insulators and semiconductors

    NASA Technical Reports Server (NTRS)

    George, A.

    1973-01-01

    Ionization energies of organic semiconductors were determined using single crystals of the material. The theory of the method is essentially that of Millikan's oil drop experiment. The technique employed in the experiment is based on the electrostatic method of balancing a charged particle in an electric field against the force of gravity for different excitation energies above the threshold value, and from an estimate of the balancing voltages, read off the ionization energy from the intercept of the energy axis in a plot wavelength corresponding to the balancing potential for the incident radiation of wavelength. In the modified technique which is adopted in the present experimental investigation, a small single crystal is suspended by a fine quartz fiber between two vertical capacitor plates to which a suitable high voltage is applied.

  8. Electrical Characterization of Graphite/InP Schottky Diodes by I-V-T and C-V Methods

    NASA Astrophysics Data System (ADS)

    Tiagulskyi, Stanislav; Yatskiv, Roman; Grym, Jan

    2018-02-01

    A rectifying junction was prepared by casting a drop of colloidal graphite on the surface of an InP substrate. The electrophysical properties of graphite/InP junctions were investigated in a wide temperature range. Temperature-dependent I-V characteristics of the graphite/InP junctions are explained by the thermionic emission mechanism. The Schottky barrier height (SBH) and the ideality factor were found to be 0.9 eV and 1.47, respectively. The large value of the SBH and its weak temperature dependence are explained by lateral homogeneity of the junction, which is related to the structure of the graphite layer. The moderate disagreement between the current-voltage and capacitance-voltage measurements is attributed to the formation of interfacial native oxide film on the InP surface.

  9. Semiconductor light source with electrically tunable emission wavelength

    DOEpatents

    Belenky, Gregory [Port Jefferson, NY; Bruno, John D [Bowie, MD; Kisin, Mikhail V [Centereach, NY; Luryi, Serge [Setauket, NY; Shterengas, Leon [Centereach, NY; Suchalkin, Sergey [Centereach, NY; Tober, Richard L [Elkridge, MD

    2011-01-25

    A semiconductor light source comprises a substrate, lower and upper claddings, a waveguide region with imbedded active area, and electrical contacts to provide voltage necessary for the wavelength tuning. The active region includes single or several heterojunction periods sandwiched between charge accumulation layers. Each of the active region periods comprises higher and lower affinity semiconductor layers with type-II band alignment. The charge carrier accumulation in the charge accumulation layers results in electric field build-up and leads to the formation of generally triangular electron and hole potential wells in the higher and lower affinity layers. Nonequillibrium carriers can be created in the active region by means of electrical injection or optical pumping. The ground state energy in the triangular wells and the radiation wavelength can be tuned by changing the voltage drop across the active region.

  10. Ion accelerator system mounting design and operating characteristics for a 5 kW 30-cm xenon ion engine

    NASA Technical Reports Server (NTRS)

    Aston, Graeme; Brophy, John R.

    1987-01-01

    Results from a series of experiments to determine the effect of accelerator grid mount geometry on the performance of the J-series ion optics assembly are described. Three mounting schemes, two flexible and one rigid, are compared for their relative ion extraction capability over a range of total accelerating voltages. The largest ion beam current, for the maximum total voltage investigated, is shown to occur using one of the flexible grid mounting geometries. However, at lower total voltages and reduced engine input power levels, the original rigid J-series ion optics accelerator grid mounts result in marginally better grid system performance at the same cold interelectrode gap.

  11. High voltage electrical injuries.

    PubMed

    Kaloudová, Y; Sín, R; Rihová, H; Brychta, R; Suchánek, I; Martincová, A

    2006-01-01

    Between 1999 and 2005, a total of 41 patients were hospitalized at the Burn Centre of Brno University Hospital with high voltage electrical injuries, representing 6.06% of the total number of patients treated at the Burn Intensive Care Unit (ICU) for extensive burn trauma. The average age of patients with serious electrotraumas was 27.29 years. The youngest patient was 9 years old, the oldest 64 years. Lethality amounted to 17.07% of the total number of patients. The article clearly shows the sinister dimension (a frighteningly high number of cases) of high voltage electrical injuries suffered outside work context in the vicinity of railway tracks and affecting in particular the youngest age groups--children.

  12. Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study

    NASA Technical Reports Server (NTRS)

    Prokopius, P. R.

    1975-01-01

    An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.

  13. Real time charge efficiency monitoring for nickel electrodes in NICD and NIH2 cells

    NASA Astrophysics Data System (ADS)

    Zimmerman, A. H.

    1987-09-01

    The charge efficiency of nickel-cadmium and nickel-hydrogen battery cells is critical in spacecraft applications for determining the amount of time required for a battery to reach a full state of charge. As the nickel-cadmium or nickel-hydrogen batteries approach about 90 percent state of charge, the charge efficiency begins to drop towards zero, making estimation of the total amount of stored charge uncertain. Charge efficiency estimates are typically based on prior history of available capacity following standardized conditions for charge and discharge. These methods work well as long as performance does not change significantly. A relatively simple method for determining charge efficiencies during real time operation for these battery cells would be a tremendous advantage. Such a method was explored and appears to be quite well suited for application to nickel-cadmium and nickel-hydrogen battery cells. The charge efficiency is monitored in real time, using only voltage measurements as inputs. With further evaluation such a method may provide a means to better manage charge control of batteries, particularly in systems where a high degree of autonomy or system intelligence is required.

  14. Effect of cathode cooling efficiency and oxygen plasma gas pressure on the hafnium cathode wall temperature

    NASA Astrophysics Data System (ADS)

    Ashtekar, Koustubh; Diehl, Gregory; Hamer, John

    2012-10-01

    The hafnium cathode is widely used in DC plasma arc cutting (PAC) under an oxygen gas environment to cut iron and iron alloys. The hafnium erosion is always a concern which is controlled by the surface temperature. In this study, the effect of cathode cooling efficiency and oxygen gas pressure on the hafnium surface temperature are quantified. The two layer cathode sheath model is applied on the refractive hafnium surface while oxygen species (O2, O, O+, O++, e-) are considered within the thermal dis-equilibrium regime. The system of non-linear equations comprising of current density balance, heat flux balance at both the cathode surface and the sheath-ionization layer is coupled with the plasma gas composition solver. Using cooling heat flux, gas pressure and current density as inputs; the cathode wall temperature, electron temperature, and sheath voltage drop are calculated. Additionally, contribution of emitted electron current (Je) and ions current (Ji) to the total current flux are estimated. Higher gas pressure usually reduces Ji and increases Je that reduces the surface temperature by thermionic cooling.

  15. Electronic drop sensing in microfluidic devices: automated operation of a nanoliter viscometer

    PubMed Central

    Srivastava, Nimisha; Burns, Mark A.

    2007-01-01

    We describe three droplet sensing techniques: a digital electrode, an analog electrode, and a thermal method. All three techniques use a single layer of metal lines that is easy to microfabricate and an electronic signal can be produced using low DC voltages. While the electrode methods utilize changes in electrical conductivity when the air/liquid interface of the droplet passes over a pair of electrodes, the thermal method is based on convective heat loss from a locally heated region. For the electrode method, the analog technique is able to detect 25 nL droplets while the digital technique is capable of detecting droplets as small as 100 pL. For thermal sensing, temperature profiles in the range of 36 °C and higher were used. Finally, we have used the digital electrode method and an array of electrodes located at preset distances to automate the operation of a previously described microfluidic viscometer. The viscometer is completely controlled by a laptop computer, and the total time for operation including setup, calibration, sample addition and viscosity calculation is approximately 4 minutes. PMID:16738725

  16. Real time charge efficiency monitoring for nickel electrodes in NICD and NIH2 cells

    NASA Technical Reports Server (NTRS)

    Zimmerman, A. H.

    1987-01-01

    The charge efficiency of nickel-cadmium and nickel-hydrogen battery cells is critical in spacecraft applications for determining the amount of time required for a battery to reach a full state of charge. As the nickel-cadmium or nickel-hydrogen batteries approach about 90 percent state of charge, the charge efficiency begins to drop towards zero, making estimation of the total amount of stored charge uncertain. Charge efficiency estimates are typically based on prior history of available capacity following standardized conditions for charge and discharge. These methods work well as long as performance does not change significantly. A relatively simple method for determining charge efficiencies during real time operation for these battery cells would be a tremendous advantage. Such a method was explored and appears to be quite well suited for application to nickel-cadmium and nickel-hydrogen battery cells. The charge efficiency is monitored in real time, using only voltage measurements as inputs. With further evaluation such a method may provide a means to better manage charge control of batteries, particularly in systems where a high degree of autonomy or system intelligence is required.

  17. Preliminary results in the NASA Lewis H2-O2 combustion MHD experiment

    NASA Technical Reports Server (NTRS)

    Smith, J. M.

    1979-01-01

    MHD (magnetohydrodynamic) power generation experiments were carried out in the NASA Lewis Research Center cesium-seeded H2-O2 combustion facility. This facility uses a neon-cooled cryomagnet capable of producing magnetic fields in excess of 5 tesla. The effects of power takeoff location, generator loading, B-field strength, and electrode breakdown on generator performance are discussed. The experimental data is compared to a theory based on one-dimensional flow with heat transfer, friction, and voltage drops.

  18. Apparatus including a plurality of spaced transformers for locating short circuits in cables

    NASA Technical Reports Server (NTRS)

    Cason, R. L.; Mcstay, J. J. (Inventor)

    1978-01-01

    A cable fault locator is described for sensing faults such as short circuits in power cables. The apparatus includes a plurality of current transformers strategically located along a cable. Trigger circuits are connected to each of the current transformers for placing a resistor in series with a resistive element responsive to an abnormally high current flowing through that portion of the cable. By measuring the voltage drop across the resistive element, the location of the fault can be determined.

  19. Anti-Le-Chatelet behavior driven by strong natural light

    NASA Astrophysics Data System (ADS)

    Antonyuk, B. P.

    2007-01-01

    We show that strong incoherent broad band light causes positive feedback in response to a static electric field in random media: electric current flows in opposite to a voltage drop direction; static polarization is induced in opposition to an applied electric field. This type of the electron motion amplifies the external action revealing anti-Le-Chatelet behavior. The applied static electric field is amplified up to the domain of optical damage of a silica glass ≈10 7 V/cm.

  20. Multifunctional Poro-Vascular Composites for UAV Performance Enhancement

    DTIC Science & Technology

    2012-07-31

    structural “skin” materials with surface pores and internal vascular channels filled with an ionic- liquid whose height and shape at the pore exits is...2 V t e e q q          Intrinsic contact angle (zero voltage) Applied potential Interfacial tension (IFT) of ionic liquid Lippmann...Characterization flat plates  single (capillary) pore  PV pore arrays FTA 1000 Drop-Shape Characterization • Microscope lens : 0.5 to 12x magnification • Side

  1. Infrared Standards to Improve Chamber 7V Beam Irradiance Calibrations

    DTIC Science & Technology

    1981-01-01

    In addition to high thermometric resolution, thermistors have another useful operational feature in that the natural log of the voltage drop is very...conjunction with a third provided by AEDC. These equations are known as: Eq. i. T R - ÷ AIT 1 where T 1 is the thermometric temperature indicated by...3.58078 x 10 -5 | Equation 3 is t h e thermometric calibration provided by AEDC relating to the natural logarithm of V I. It is repeated here for

  2. Performance evaluation of parallel electric field tunnel field-effect transistor by a distributed-element circuit model

    NASA Astrophysics Data System (ADS)

    Morita, Yukinori; Mori, Takahiro; Migita, Shinji; Mizubayashi, Wataru; Tanabe, Akihito; Fukuda, Koichi; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shin-ichi; Liu, Yongxun; Masahara, Meishoku; Ota, Hiroyuki

    2014-12-01

    The performance of parallel electric field tunnel field-effect transistors (TFETs), in which band-to-band tunneling (BTBT) was initiated in-line to the gate electric field was evaluated. The TFET was fabricated by inserting an epitaxially-grown parallel-plate tunnel capacitor between heavily doped source wells and gate insulators. Analysis using a distributed-element circuit model indicated there should be a limit of the drain current caused by the self-voltage-drop effect in the ultrathin channel layer.

  3. Design and assessment of a robust voltage amplifier with 2.5 GHz GBW and >100 kGy total dose tolerance

    NASA Astrophysics Data System (ADS)

    Verbeeck, J.; Leroux, P.; Steyaert, M.

    2011-01-01

    A differential voltage amplifier with a gain-bandwidth product of 2.5Ghz and using adaptive biasing has been designed in a standard CMOS technology and assessed under radiation and temperature variations. The principle used in this ASIC will be employed in the design of a Gbps TIA with improved tolerance for γ-irradiation and temperature for an optical instrumentation (LIDAR) receiver aiming at operation in harsh environments. The voltage amplifier was tested under gamma radiation and features a gain degradation of merely 4.5% up to a total dose of 100kGy. In order to verify the radiation effects on the IC, the threshold voltage shift of the separate transistors has been investigated. Temperature characterization has shown that the amplifier features a reduction of the voltage gain by only 5.6% for a temperature range of -40 till 130 °C.

  4. Estimates of outage costs of electricity in Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashraf, J.; Sabih, F.

    1993-12-31

    This article estimates outage costs of electricity for each of the four provinces in Pakistan (Punjab, North-West Frontier Province, Baluchistan, and Sind). The term {open_quotes}power outage{close_quotes} refers to all problems associated with electricity supply, such as voltage drops (brownouts), power failures (blackouts), and load shedding. The most significant of these in Pakistan is load shedding when power supply to different consumers is shut off during different times of the day, especially during peak hours when the pressure on the system is the highest. Power shortages mainly arise during the low-water months when the effective capacity of hydropower plants drops significantly.more » This decline in power supplied by hydro plants cannot be made up by operating thermal power plants because of the limited availability of gas and the high cost of alternative fuels required for the operation of gas turbines.« less

  5. Measurement of high-temperature spectral emissivity using integral blackbody approach

    NASA Astrophysics Data System (ADS)

    Pan, Yijie; Dong, Wei; Lin, Hong; Yuan, Zundong; Bloembergen, Pieter

    2016-11-01

    Spectral emissivity is one of the most critical thermophysical properties of a material for heat design and analysis. Especially in the traditional radiation thermometry, normal spectral emissivity is very important. We developed a prototype instrument based upon an integral blackbody method to measure material's spectral emissivity at elevated temperatures. An optimized commercial variable-high-temperature blackbody, a high speed linear actuator, a linear pyrometer, and an in-house designed synchronization circuit was used to implemented the system. A sample was placed in a crucible at the bottom of the blackbody furnace, by which the sample and the tube formed a simulated reference blackbody which had an effective total emissivity greater than 0.985. During the measurement, a pneumatic cylinder pushed a graphite rode and then the sample crucible to the cold opening within hundreds of microseconds. The linear pyrometer was used to monitor the brightness temperature of the sample surface, and the corresponding opto-converted voltage was fed and recorded by a digital multimeter. To evaluate the temperature drop of the sample along the pushing process, a physical model was proposed. The tube was discretized into several isothermal cylindrical rings, and the temperature of each ring was measurement. View factors between sample and rings were utilized. Then, the actual surface temperature of the sample at the end opening was obtained. Taking advantages of the above measured voltage signal and the calculated actual temperature, normal spectral emissivity under the that temperature point was obtained. Graphite sample at 1300°C was measured to prove the validity of the method.

  6. Droppings From Captive Coturnix coturnix (Galliformes: Phasianidae) as a Fly Breeding Resource

    PubMed Central

    Horenstein, M. Battán; Lynch-Ianniello, I.; de Dio, B.; Gleiser, R. M.

    2014-01-01

    Abstract The aim of this study was to describe the fauna of flies associated with captive Coturnix coturnix (L.) (Galliformes: Phasianidae) droppings. Samples of 150 g of quail droppings were exposed in the quail house for 48 h in plastic containers to promote eventual access of flies, and then placed in emergence traps. The number of adults and species emerging was recorded daily. This procedure was carried out in spring 2008 and spring and autumn 2009. In total, 2,138 adults belonging to Muscidae, Calliphoridae, Piophilidae, Phoridae, Fanniidae, and Milichiidae families were collected. The most numerous family was Muscidae (representing >82% of the total specimens), with Musca domestica L. being the most abundant species followed by Ophyra aenescens (Wiedemann) (both Diptera: Muscidae). Quail breeding should include adequate droppings management policies to avoid potential sanitary issues related to fly production. PMID:25347840

  7. In Situ X-ray Diffraction Studies on the Mechanism of Capacity Retention Improvement by Coating at the Surface of Li CoO2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung,K.; Yoon, W.; McBreen, J.

    2007-01-01

    Synchrotron based in situ X-ray diffraction technique has been used to study the mechanism of capacity fading of LiCoO2 cycled to a higher voltage above the normal 4.2 V limit and to investigate the mechanism of capacity retention improvement by ZrO2 surface coating on LiCoO2. It was found that the capacity fading of LiCoO2 cycled at higher voltage limit is closely related to the increased polarization rather than the bulk crystal structure damage. The capacity of uncoated LiCoO2 sample dropped to less than 70 mAh g-1 when charged to 4.8 V after high voltage cycling. However, when the voltage limitmore » was further increased to 8.35 V, the capacity was partially restored and the corresponding structural changes were recovered to the similar level as seen in fresh sample. This indicates that the integrity of the bulk crystal structure of LiCoO2 was not seriously damaged during cycling to 4.8 V. The increased polarization seems to be responsible for the fading capacity and the uncompleted phase transformation of LiCoO2. The polarization-induced capacity fading can be significantly improved by ZrO2 surface coating. It was proposed that the effect of ZrO2-coating layer on the capacity retention during high voltage cycling is through the formation of protection layer on the surface of LiCoO2 particles, which can reduce the decomposition of the electrolyte at higher voltages.« less

  8. Energy reduction through voltage scaling and lightweight checking

    NASA Astrophysics Data System (ADS)

    Kadric, Edin

    As the semiconductor roadmap reaches smaller feature sizes and the end of Dennard Scaling, design goals change, and managing the power envelope often dominates delay minimization. Voltage scaling remains a powerful tool to reduce energy. We find that it results in about 60% geomean energy reduction on top of other common low-energy optimizations with 22nm CMOS technology. However, when voltage is reduced, it becomes easier for noise and particle strikes to upset a node, potentially causing Silent Data Corruption (SDC). The 60% energy reduction, therefore, comes with a significant drop in reliability. Duplication with checking and triple-modular redundancy are traditional approaches used to combat transient errors, but spending 2--3x the energy for redundant computation can diminish or reverse the benefits of voltage scaling. As an alternative, we explore the opportunity to use checking operations that are cheaper than the base computation they are guarding. We devise a classification system for applications and their lightweight checking characteristics. In particular, we identify and evaluate the effectiveness of lightweight checks in a broad set of common tasks in scientific computing and signal processing. We find that the lightweight checks cost only a fraction of the base computation (0-25%) and allow us to recover the reliability losses from voltage scaling. Overall, we show about 50% net energy reduction without compromising reliability compared to operation at the nominal voltage. We use FPGAs (Field-Programmable Gate Arrays) in our work, although the same ideas can be applied to different systems. On top of voltage scaling, we explore other common low-energy techniques for FPGAs: transmission gates, gate boosting, power gating, low-leakage (high-Vth) processes, and dual-V dd architectures. We do not scale voltage for memories, so lower voltages help us reduce logic and interconnect energy, but not memory energy. At lower voltages, memories become dominant, and we get diminishing returns from continuing to scale voltage. To ensure that memories do not become a bottleneck, we also design an energy-robust FPGA memory architecture, which attempts to minimize communication energy due to mismatches between application and architecture. We do this alongside application parallelism tuning. We show our techniques on a wide range of applications, including a large real-time system used for Wide-Area Motion Imaging (WAMI).

  9. Electric-Field-Induced Degradation of Methylammonium Lead Iodide Perovskite Solar Cells.

    PubMed

    Bae, Soohyun; Kim, Seongtak; Lee, Sang-Won; Cho, Kyung Jin; Park, Sungeun; Lee, Seunghun; Kang, Yoonmook; Lee, Hae-Seok; Kim, Donghwan

    2016-08-18

    Perovskite solar cells have great potential for high efficiency generation but are subject to the impact of external environmental conditions such as humidity, UV and sun light, temperature, and electric fields. The long-term stability of perovskite solar cells is an important issue for their commercialization. Various studies on the stability of perovskite solar cells are currently being performed; however, the stability related to electric fields is rarely discussed. Here the electrical stability of perovskite solar cells is studied. Ion migration is confirmed using the temperature-dependent dark current decay. Changes in the power conversion efficiency according to the amount of the external bias are measured in the dark, and a significant drop is observed only at an applied voltage greater than 0.8 V. We demonstrate that perovskite solar cells are stable under an electric field up to the operating voltage.

  10. Switching dynamics of TaOx-based threshold switching devices

    NASA Astrophysics Data System (ADS)

    Goodwill, Jonathan M.; Gala, Darshil K.; Bain, James A.; Skowronski, Marek

    2018-03-01

    Bi-stable volatile switching devices are being used as access devices in solid-state memory arrays and as the active part of compact oscillators. Such structures exhibit two stable states of resistance and switch between them at a critical value of voltage or current. A typical resistance transient under a constant amplitude voltage pulse starts with a slow decrease followed by a rapid drop and leveling off at a low steady state value. This behavior prompted the interpretation of initial delay and fast transition as due to two different processes. Here, we show that the entire transient including incubation time, transition time, and the final resistance values in TaOx-based switching can be explained by one process, namely, Joule heating with the rapid transition due to the thermal runaway. The time, which is required for the device in the conducting state to relax back to the stable high resistance one, is also consistent with the proposed mechanism.

  11. Biased four-point probe resistance

    NASA Astrophysics Data System (ADS)

    Garcia-Vazquez, Valentin

    2017-11-01

    The implications of switching the current polarity in a four-point probe resistance measurement are presented. We demonstrate that, during the inversion of the applied current, any change in the voltage V produced by a continuous drop of the sample temperature T will induce a bias in the temperature-dependent DC resistance. The analytical expression for the bias is deduced and written in terms of the variations of the measured voltages with respect to T and by the variations of T with respect to time t. Experimental data measured on a superconducting Nb thin film confirm that the bias of the normal-state resistance monotonically increases with the cooling rate dT/dt while keeping fixed dV/dT; on the other hand, the bias increases with dV/dT, reaching values up to 13% with respect to the unbiased resistance obtained at room temperature.

  12. Quality Health Care for Children and the Affordable Care Act: A Voltage Drop Checklist

    PubMed Central

    Wise, Paul H.; Halfon, Neal

    2014-01-01

    The Affordable Care Act (ACA) introduces enormous policy changes to the health care system with several anticipated benefits and a growing number of unanticipated challenges for child and adolescent health. Because the ACA gives each state and their payers substantial autonomy and discretion on implementation, understanding potential effects will require state-by-state monitoring of policies and their impact on children. The “voltage drop” framework is a useful interpretive guide for assessing the impact of insurance market change on the quality of care received. Using this framework we suggest a state-level checklist to examine ACA statewide implementation, assess its impact on health care delivery, and frame policy correctives to improve child health system performance. Although children’s health care is a small part of US health care spending, child health provides the foundation for adult health and must be protected in ACA implementation. PMID:25225140

  13. Self-powered wireless disposable sensor for welfare application.

    PubMed

    Douseki, Takakuni; Tanaka, Ami

    2013-01-01

    A self-powered urinary incontinence sensor consisting of a flexible urine-activated battery and a wireless transmitter has been developed as an application for wireless biosensor networks. The flexible urine-activated battery is embedded in a disposal diaper and makes possible both the sensing of urine leakage and self-powered operation. An intermittent power-supply circuit that uses an electric double-layer capacitor (EDLC) with a small internal resistance suppresses the supply voltage drop due to the large internal resistance of the battery. This circuit supplies the power to a wireless transmitter. A 315-MHz-band wireless transmitter performs low-power operation. To verify the effectiveness of the circuit scheme, we fabricated a prototype sensor system. When 80 cc of urine is poured onto the diaper, the battery outputs a voltage of 1 V; and the sensor can transmit an ID signal over a distance of 5 m.

  14. Primary thermometry with nanoscale tunnel junctions

    NASA Astrophysics Data System (ADS)

    Hirvi, K. P.; Kauppinen, J. P.; Paalanen, M. A.; Pekola, J. P.

    1995-10-01

    We have found current-voltage (I-V) and conductance (dI/dV) characteristics of arrays of nanoscale tunnel junctions between normal metal electrodes to exhibit suitable features for primary thermometry. The current through a uniform array depends on the ratio of the thermal energy kBT and the electrostatic charging energy E c of the islands between the junctions and is completely blocked by Coulomb repulsion at T = 0 and at small voltages eV/2 ≤ Ec. In the opposite limit, kBT ≫ Ec, the width of the conductance minimum scales linearly and universally with T and N, the number of tunnel junctions, and qualifies as a primary thermometer. The zero bias drop in the conductance is proportional to T-1 and can be used as a secondary thermometer. We will show with Monte Carlo simulations how background charge and nonuniformities of the array will affect the thermometer.

  15. Intelligent control for PMSM based on online PSO considering parameters change

    NASA Astrophysics Data System (ADS)

    Song, Zhengqiang; Yang, Huiling

    2018-03-01

    A novel online particle swarm optimization method is proposed to design speed and current controllers of vector controlled interior permanent magnet synchronous motor drives considering stator resistance variation. In the proposed drive system, the space vector modulation technique is employed to generate the switching signals for a two-level voltage-source inverter. The nonlinearity of the inverter is also taken into account due to the dead-time, threshold and voltage drop of the switching devices in order to simulate the system in the practical condition. Speed and PI current controller gains are optimized with PSO online, and the fitness function is changed according to the system dynamic and steady states. The proposed optimization algorithm is compared with conventional PI control method in the condition of step speed change and stator resistance variation, showing that the proposed online optimization method has better robustness and dynamic characteristics compared with conventional PI controller design.

  16. Enhancing power density of strained In0.8Ga0.2As/AlAs resonant tunneling diode for terahertz radiation by optimizing emitter spacer layer thickness

    NASA Astrophysics Data System (ADS)

    Shi, Xiangyang; Wu, Yuanyuan; Wang, Ding; Su, Juan; Liu, Jie; Yang, Wenxian; Xiao, Meng; Tan, Wei; Lu, Shulong; Zhang, Jian

    2017-12-01

    We demonstrate both theoretically and experimentally that the power density of resonant tunneling diode (RTD) can be enhanced by optimizing emitter spacer layer thickness, in addition to reducing barrier thickness. Compared to the widely used epitaxial structure with ultrathin emitter spacer layer thickness, appropriate increasing the thickness will increase the voltage drop in accumulation region, leading to larger voltage widths of negative differential resistance region. By measuring J-V characteristics, the specific contact resistivity, and the self-capacitance, we theoretically analyze the maximum output power of the fabricated RTDs. It shows that the optimized In0.8Ga0.2As/AlAs RTD with 20 nm emitter spacer thickness and 5 μm2 mesa area theoretically possesses the capability to reach 3.1 mW at 300 GHz and 1.8 mW at 600 GHz.

  17. Field emission from carbon nanotube fibers in varying anode-cathode gap with the consideration of contact resistance

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Fairchild, S. B.; Back, T. C.; Luo, Yi

    2017-12-01

    This paper studies field emission (FE) from a single carbon nanotube (CNT) fiber with different anode-cathode (AK) gap distances. It is found that the field enhancement factor depends strongly on the finite AK gap distance, due to the combination of geometrical effects and possible fiber morphology change. The geometrical effects of AK gap distance on the field enhancement factor are confirmed using COMSOL simulations. The slope drop in the Fowler-Northeim (FN) plot of the FE data in the high voltage is related to the electrical contact resistance between the CNT fiber and the substrate. It is found that even a small series resistance to the field emitter (<30% of the emission gap impedance) can strongly modify the FE characteristics in the high voltage regime, inducing a strong deviation from the linear FN plot.

  18. Triple Hybrid Energy Harvesting Interface Electronics

    NASA Astrophysics Data System (ADS)

    Uluşan, H.; Chamanian, S.; Pathirana, W. M. P. R.; Zorlu, Ö.; Muhtaroğlu, A.; Külah, H.

    2016-11-01

    This study presents a novel triple hybrid system that combines simultaneously generated power from thermoelectric (TE), vibration-based electromagnetic (EM) and piezoelectric (PZT) harvesters for a relatively high power supply capability. In the proposed solution each harvesting source utilizes a distinct power management circuit that generates a DC voltage suitable for combining the three parallel supplies. The circuits are designed and implemented in 180 nm standard CMOS technology, and are terminated with a schottky diode to avoid reverse current flow. The harvested AC signal from the EM harvester is rectified with a self-powered AC-DC doubler, which utilizes active diode structures to minimize the forward- bias voltage drop. The PZT interface electronics utilizes a negative voltage converter as the first stage, followed by synchronous power extraction and DC-to-DC conversion through internal switches, and an external inductor. The ultra-low voltage DC power harvested by the TE generator is stepped up through a charge-pump driven by an LC oscillator with fully- integrated center-tapped differential inductors. Test results indicate that hybrid energy harvesting circuit provides more than 1 V output for load resistances higher than 100 kΩ (10 μW) where the stand-alone harvesting circuits are not able to reach 1 V output. This is the first hybrid harvester circuit that simultaneously extracts energy from three independent sources, and delivers a single DC output.

  19. Domestic wastewater treatment and power generation in continuous flow air-cathode stacked microbial fuel cell: Effect of series and parallel configuration.

    PubMed

    Estrada-Arriaga, Edson Baltazar; Hernández-Romano, Jesús; García-Sánchez, Liliana; Guillén Garcés, Rosa Angélica; Bahena-Bahena, Erick Obed; Guadarrama-Pérez, Oscar; Moeller Chavez, Gabriela Eleonora

    2018-05-15

    In this study, a continuous flow stack consisting of 40 individual air-cathode MFC units was used to determine the performance of stacked MFC during domestic wastewater treatment operated with unconnected individual MFC and in series and parallel configuration. The voltages obtained from individual MFC units were of 0.08-1.1 V at open circuit voltage, while in series connection, the maximum power and current density were 2500 mW/m 2 and 500 mA/m 2 (4.9 V), respectively. In parallel connection, the maximum power and current density was 5.8 mW/m 2 and 24 mA/m 2 , respectively. When the cells were not connected to each other MFC unit, the main bacterial species found in the anode biofilms were Bacillus and Lysinibacillus. After switching from unconnected to series and parallel connections, the most abundant species in the stacked MFC were Pseudomonas aeruginosa, followed by different Bacilli classes. This study demonstrated that when the stacked MFC was switched from unconnected to series and parallel connections, the pollutants removal, performance electricity and microbial community changed significantly. Voltages drops were observed in the stacked MFC, which was mainly limited by the cathodes. These voltages loss indicated high resistances within the stacked MFC, generating a parasitic cross current. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. A 13.56 MHz CMOS Active Rectifier With Switched-Offset and Compensated Biasing for Biomedical Wireless Power Transfer Systems.

    PubMed

    Yan Lu; Wing-Hung Ki

    2014-06-01

    A full-wave active rectifier switching at 13.56 MHz with compensated bias current for a wide input range for wirelessly powered high-current biomedical implants is presented. The four diodes of a conventional passive rectifier are replaced by two cross-coupled PMOS transistors and two comparator- controlled NMOS switches to eliminate diode voltage drops such that high voltage conversion ratio and power conversion efficiency could be achieved even at low AC input amplitude |VAC|. The comparators are implemented with switched-offset biasing to compensate for the delays of active diodes and to eliminate multiple pulsing and reverse current. The proposed rectifier uses a modified CMOS peaking current source with bias current that is quasi-inversely proportional to the supply voltage to better control the reverse current over a wide AC input range (1.5 to 4 V). The rectifier was fabricated in a standard 0.35 μm CMOS N-well process with active area of 0.0651 mm(2). For the proposed rectifier measured at |VAC| = 3.0 V, the voltage conversion ratios are 0.89 and 0.93 for RL=500 Ω and 5 kΩ, respectively, and the measured power conversion efficiencies are 82.2% to 90.1% with |VAC| ranges from 1.5 to 4 V for RL=500 Ω.

  1. A study on the high temperature-dependence of the electrical properties in a solution-deposited zinc-tin-oxide thin-film transistor operated in the saturation region

    NASA Astrophysics Data System (ADS)

    Yu, Kyeong Min; Bae, Byung Seong; Jung, Myunghee; Yun, Eui-Jung

    2016-06-01

    We investigate the effects of high temperatures in the range of 292 - 393 K on the electrical properties of solution-processed amorphous zinc-tin-oxide (a-ZTO) thin-film transistors (TFTs) operated in the saturation region. The fabricated a-ZTO TFTs have a non-patterned bottom gate and top contact structure, and they use a heavily-doped Si wafer and SiO2 as a gate electrode and a gate insulator layer, respectively. In a-ZTO TFTs, the trap release energy ( E TR ) was deduced by using Maxwell-Boltzmann statistics. The decreasing E TR toward zero with increasing gate voltage (the density of trap states ( n s )) in the a-ZTO active layer can be attributed to a shift of the Fermi level toward the mobility edge with increasing gate voltage. The TFTs with low gate voltage (low n s ) exhibit multiple trap and release characteristics and show thermally-activated behavior. In TFTs with a high gate voltage (high n s ), however, we observe decreasing mobility and conductivity with increasing temperature at temperatures ranging from 303 to 363 K. This confirms that the E TR can drop to zero, indicating a shift of the Fermi level beyond the mobility edge. Hence, the mobility edge is detected at the cusp between thermally-activated transport and band transport.

  2. Linearisation of λDNA molecules by instantaneous variation of the trapping electrode voltage inside a micro-channel

    NASA Astrophysics Data System (ADS)

    Hanasaki, Itsuo; Yukimoto, Naoya; Uehara, Satoshi; Shintaku, Hirofumi; Kawano, Satoyuki

    2015-04-01

    Because long DNA molecules usually exist in random coil states due to the entropic effect, linearisation is required for devices equipped with nanopores where electrical sequencing is necessary during single-file translocation. We present a novel technique for linearising DNA molecules in a micro-channel. In our device, electrodes are embedded in the bottom surface of the channel. The application of a voltage induces the trapping of λDNA molecules on the positive electrode. An instantaneous voltage drop is used to put the λDNA molecules in a partly released state and the hydrodynamic force of the solution induces linearisation. Phenomena were directly observed using an optical microscopy system equipped with a high-speed camera and the linearisation principle was explored in detail. Furthermore, we estimate the tensile characteristics produced by the flow of the solution through a numerical model of a tethered polymer subject to a Poiseuille flow. The mean tensile force is in the range of 0.1-1 pN. This is sufficiently smaller than the structural transition point of λDNA but counterbalances the entropic elasticity that causes the random coil shape of λDNA molecules in solution. We show the important role of thermal fluctuation in the manipulation of molecules in solution and clarify the tensile conditions required for DNA linearisation using a combination of solution flow and voltage variation in a microchannel.

  3. Current Flow in the Bubble and Stripe Phases

    NASA Astrophysics Data System (ADS)

    Friess, B.; Umansky, V.; von Klitzing, K.; Smet, J. H.

    2018-03-01

    The spontaneous ordering of spins and charges in geometric patterns is currently under scrutiny in a number of different material systems. A topic of particular interest is the interaction of such ordered phases with itinerant electrons driven by an externally imposed current. It not only provides important information on the charge ordering itself but potentially also allows manipulating the shape and symmetry of the underlying pattern if current flow is strong enough. Unfortunately, conventional transport methods probing the macroscopic resistance suffer from the fact that the voltage drop along the sample edges provides only indirect information on the bulk properties because a complex current distribution is elicited by the inhomogeneous ground state. Here, we promote the use of surface acoustic waves to study these broken-symmetry phases and specifically address the bubble and stripe phases emerging in high-quality two-dimensional electron systems in GaAs /AlGaAs heterostructures as prototypical examples. When driving a unidirectional current, we find a surprising discrepancy between the sound propagation probing the bulk of the sample and the voltage drop along the sample edges. Our results prove that the current-induced modifications observed in resistive transport measurements are in fact a local phenomenon only, leaving the majority of the sample unaltered. More generally, our findings shed new light on the extent to which these ordered electron phases are impacted by an external current and underline the intrinsic advantages of acoustic measurements for the study of such inhomogeneous phases.

  4. Analysis of the convective evaporation of nondilute clusters of drops

    NASA Technical Reports Server (NTRS)

    Bellan, J.; Harstad, K.

    1987-01-01

    The penetration distance of an outer flow into a drop cluster volume is the critical, evaporation mode-controlling parameter in the present model for nondilute drop clusters' convective evaporation. The model is found to perform well for such low penetration distances as those obtained for dense clusters in hot environments and low relative velocities between the outer gases and the cluster. For large penetration distances, however, the predictive power of the model deteriorates; in addition, the evaporation time is found to be a weak function of the initial relative velocity and a strong function of the initial drop temperature. The results generally show that the interior drop temperature was transient throughout the drop lifetime, although temperature nonuniformities persisted up to the first third of the total evaporation time at most.

  5. Single-contact tunneling thermometry

    DOEpatents

    Maksymovych, Petro

    2016-02-23

    A single-contact tunneling thermometry circuit includes a tunnel junction formed between two objects. Junction temperature gradient information is determined based on a mathematical relationship between a target alternating voltage applied across the junction and the junction temperature gradient. Total voltage measured across the junction indicates the magnitude of the target alternating voltage. A thermal gradient is induced across the junction. A reference thermovoltage is measured when zero alternating voltage is applied across the junction. An increasing alternating voltage is applied while measuring a thermovoltage component and a DC rectification voltage component created by the applied alternating voltage. The target alternating voltage is reached when the thermovoltage is nullified or doubled by the DC rectification voltage depending on the sign of the reference thermovoltage. Thermoelectric current and current measurements may be utilized in place of the thermovoltage and voltage measurements. The system may be automated with a feedback loop.

  6. [Corneal reepithelialization time with instillation of eye drops containing sodium hyaluronate and carboxymethylcellulose].

    PubMed

    Moreira, Luciane Bugman; Scalco, Rochelli; Hara, Silvia

    2013-10-01

    Evaluate the time of post-abrasion corneal re-epithelialization using commercially available eye drops, one of which containing 0.4% sodium hialuronate, and the other containing 1% carboxymethylcellulose, and compare them to the re-epithelialization without the drops. 24 rabbits were used, which had the mechanical abrasion of the central 8 mm of their corneas done. These animals were divided in 3 groups. The first one received the drops containing 0.4% of sodium hialuronate, the second one received the drops containing 1% of carboxymethylcellulose and the third group did not receive any drugs. The evaluations took place every 24 hours through the analysis of digital pictures under cobalt blue light and coloring of the corneas with 2% fluorescein. The pictures were analyzed with the software Autocad 2009®. The data was analyzed through the comparison of the total re-epithelialization time among the three groups The time of total re-epithelialization of the group using sodium hialuronate was on average 90 hours and the group using carboxymethylcellulose 105 hours, while the group using no drugs was 108 hours. There was a better performance of those groups using the drops and this difference can be proved statistically. The drops containing 0.4% of sodium hialuronate showed a higher efficiency rate compared to the drops containing 1% of carboxymethylcellulose, which was higher than the control group. The results of the present study show that the use of lubricants in the process of re-epithelialization are extremely valid and must be used frequently in ophthalmologic clinic.

  7. Development of design technique for vacuum insulation in large size multi-aperture multi-grid accelerator for nuclear fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kojima, A., E-mail: kojima.atsushi@jaea.go.jp; Hanada, M.; Tobari, H.

    Design techniques for the vacuum insulation have been developed in order to realize a reliable voltage holding capability of multi-aperture multi-grid (MAMuG) accelerators for fusion application. In this method, the nested multi-stage configuration of the MAMuG accelerator can be uniquely designed to satisfy the target voltage within given boundary conditions. The evaluation of the voltage holding capabilities of each acceleration stages was based on the previous experimental results about the area effect and the multi-aperture effect. Since the multi-grid effect was found to be the extension of the area effect by the total facing area this time, the total voltagemore » holding capability of the multi-stage can be estimated from that per single stage by assuming the stage with the highest electric field, the total facing area, and the total apertures. By applying these consideration, the analysis on the 3-stage MAMuG accelerator for JT-60SA agreed well with the past gap-scan experiments with an accuracy of less than 10% variation, which demonstrated the high reliability to design MAMuG accelerators and also multi-stage high voltage bushings.« less

  8. Silicon Carbide Emitter Turn-Off Thyristor

    DOE PAGES

    Wang, Jun; Wang, Gangyao; Li, Jun; ...

    2008-01-01

    A novel MOS-conmore » trolled SiC thyristor device, the SiC emitter turn-off thyristor (ETO) is a promising technology for future high-voltage switching applications because it integrates the excellent current conduction capability of a SiC thyristor with a simple MOS-control interface. Through unity-gain turn-off, the SiC ETO also achieves excellent Safe Operation Area (SOA) and faster switching speeds than silicon ETOs. The world's first 4.5-kV SiC ETO prototype shows a forward voltage drop of 4.26 V at 26.5  A / cm 2 current density at room and elevated temperatures. Tested in an inductive circuit with a 2.5 kV DC link voltage and a 9.56-A load current, the SiC ETO shows a fast turn-off time of 1.63 microseconds and a low 9.88 mJ turn-off energy. The low switching loss indicates that the SiC ETO could operate at about 4 kHz if 100  W / cm 2 conduction and the 100  W / cm 2 turn-off losses can be removed by the thermal management system. This frequency capability is about 4 times higher than 4.5-kV-class silicon power devices. The preliminary demonstration shows that the SiC ETO is a promising candidate for high-frequency, high-voltage power conversion applications, and additional developments to optimize the device for higher voltage (>5 kV) and higher frequency (10 kHz) are needed.« less

  9. Mechanism of the entire overdischarge process and overdischarge-induced internal short circuit in lithium-ion batteries.

    PubMed

    Guo, Rui; Lu, Languang; Ouyang, Minggao; Feng, Xuning

    2016-07-22

    Lithium-ion batteries connected in series are prone to be overdischarged. Overdischarge results in various side effects, such as capacity degradation and internal short circuit (ISCr). However, most of previous research on the overdischarge of a cell was terminated when the cell voltage dropped to 0 V, leaving the further impacts of overdischarge unclear. This paper investigates the entire overdischarge process of large-format lithium-ion batteries by discharging the cell to -100% state of charge (SOC). A significant voltage platform is observed at approximately -12% SOC, and ISCr is detected after the cell is overdischarged when passing the platform. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) results indicate that the overdischarge-induced ISCr is caused by Cu deposition on electrodes, suggesting possible Cu collector dissolution at the voltage platform near -12% SOC. A prognostic/mechanistic model considering ISCr is used to evaluate the resistance of ISCr (RISCr), the value of which decreases sharply at the beginning of ISCr formation. Inducing the ISCr by overdischarge is effective and well controlled without any mechanical deformation or the use of a foreign substance.

  10. Influence of the anisotropy on the performance of D-band SiC IMPATT diodes

    NASA Astrophysics Data System (ADS)

    Chen, Qing; Yang, Lin'an; Wang, Shulong; Zhang, Yue; Dai, Yang; Hao, Yue

    2015-03-01

    Numerical simulation has been made to predict the RF performance of <0001> direction and <> direction p+/n/n-/n+ (single drift region) 4H silicon carbide (4H-SiC) impact-ionization-avalanche-transit-time (IMPATT) diodes for operation at D-band frequencies. We observed that the output performance of 4H-SiC IMPATT diode is sensitive to the crystal direction of the one-dimensional current flow. The simulation results show that <0001> direction 4H-SiC IMPATT diode provides larger breakdown voltage for its lower electron and hole ionization rates and higher dc-to-rf conversion efficiency (η) for its higher ratio of drift zone voltage drop (VD) to breakdown voltage (VB) compared with those for <> direction 4H-SiC IMPATT diode, which lead to higher-millimeter-wave power output for <0001> direction 4H-SiC IMPATT compared to <> direction. However, the quality factor Q for the <> direction 4H-SiC IMPATT diode is lower than that of <0001> direction, which implies that the <> direction 4H-SiC IMPATT diode exhibits better stability and higher growth rate of microwave oscillation compared with <0001> direction 4H-SiC IMPATT diode.

  11. High Voltage Dielectrophoretic and Magnetophoretic Hybrid Integrated Circuit / Microfluidic Chip

    PubMed Central

    Issadore, David; Franke, Thomas; Brown, Keith A.; Hunt, Thomas P.; Westervelt, Robert M.

    2010-01-01

    A hybrid integrated circuit (IC) / microfluidic chip is presented that independently and simultaneously traps and moves microscopic objects suspended in fluid using both electric and magnetic fields. This hybrid chip controls the location of dielectric objects, such as living cells and drops of fluid, on a 60 × 61 array of pixels that are 30 × 38 μm2 in size, each of which can be individually addressed with a 50 V peak-to-peak, DC to 10 MHz radio frequency voltage. These high voltage pixels produce electric fields above the chip’s surface with a magnitude , resulting in strong dielectrophoresis (DEP) forces . Underneath the array of DEP pixels there is a magnetic matrix that consists of two perpendicular sets of 60 metal wires running across the chip. Each wire can be sourced with 120 mA to trap and move magnetically susceptible objects using magnetophoresis (MP). The DEP pixel array and magnetic matrix can be used simultaneously to apply forces to microscopic objects, such as living cells or lipid vesicles, that are tagged with magnetic nanoparticles. The capabilities of the hybrid IC / microfluidic chip demonstrated in this paper provide important building blocks for a platform for biological and chemical applications. PMID:20625468

  12. High Voltage Dielectrophoretic and Magnetophoretic Hybrid Integrated Circuit / Microfluidic Chip.

    PubMed

    Issadore, David; Franke, Thomas; Brown, Keith A; Hunt, Thomas P; Westervelt, Robert M

    2009-12-01

    A hybrid integrated circuit (IC) / microfluidic chip is presented that independently and simultaneously traps and moves microscopic objects suspended in fluid using both electric and magnetic fields. This hybrid chip controls the location of dielectric objects, such as living cells and drops of fluid, on a 60 × 61 array of pixels that are 30 × 38 μm(2) in size, each of which can be individually addressed with a 50 V peak-to-peak, DC to 10 MHz radio frequency voltage. These high voltage pixels produce electric fields above the chip's surface with a magnitude , resulting in strong dielectrophoresis (DEP) forces . Underneath the array of DEP pixels there is a magnetic matrix that consists of two perpendicular sets of 60 metal wires running across the chip. Each wire can be sourced with 120 mA to trap and move magnetically susceptible objects using magnetophoresis (MP). The DEP pixel array and magnetic matrix can be used simultaneously to apply forces to microscopic objects, such as living cells or lipid vesicles, that are tagged with magnetic nanoparticles. The capabilities of the hybrid IC / microfluidic chip demonstrated in this paper provide important building blocks for a platform for biological and chemical applications.

  13. Silicon Carbide Diodes Performance Characterization and Comparison With Silicon Devices

    NASA Technical Reports Server (NTRS)

    Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Trapp, Scott

    2003-01-01

    Commercially available silicon carbide (SiC) Schottky diodes from different manufacturers were electrically tested and characterized at room temperature. Performed electrical tests include steady state forward and reverse I-V curves, as well as switching transient tests performed with the diodes operating in a hard switch dc-to-dc buck converter. The same tests were performed in current state of the art silicon (Si) and gallium arsenide (GaAs) Schottky and pn junction devices for evaluation and comparison purposes. The SiC devices tested have a voltage rating of 200, 300, and 600 V. The comparison parameters are forward voltage drop at rated current, reverse current at rated voltage and peak reverse recovery currents in the dc to dc converter. Test results show that steady state characteristics of the tested SiC devices are not superior to the best available Si Schottky and ultra fast pn junction devices. Transient tests reveal that the tested SiC Schottky devices exhibit superior transient behavior. This is more evident at the 300 and 600 V rating where SiC Schottky devices showed drastically lower reverse recovery currents than Si ultra fast pn diodes of similar rating.

  14. Performance evaluation of bipolar and tripolar excitations during nozzle-jetting-based alginate microsphere fabrication

    NASA Astrophysics Data System (ADS)

    Herran, C. Leigh; Huang, Yong; Chai, Wenxuan

    2012-08-01

    Microspheres, small spherical (polymeric) particles with or without second phase materials embedded or encapsulated, are important for many biomedical applications such as drug delivery and organ printing. Scale-up fabrication with the ability to precisely control the microsphere size and morphology has always been of great manufacturing interest. The objective of this work is to experimentally study the performance differences of bipolar and tripolar excitation waveforms in using drop-on-demand (DOD)-based single nozzle jetting for alginate microsphere fabrication. The fabrication performance has been evaluated based on the formability of alginate microspheres as a function of materials properties (sodium alginate and calcium chloride concentrations) and operating conditions. The operating conditions for each excitation include voltage rise/fall times, dwell times and excitation voltage amplitudes. Overall, the bipolar excitation is more robust in making spherical, monodispersed alginate microspheres as good microspheres for its wide working range of material properties and operating conditions, especially during the fabrication of highly viscous materials such as the 2% sodium alginate solution. For both bipolar and tripolar excitations, the sodium alginate concentration and the voltage dwell times should be carefully selected to achieve good microsphere formability.

  15. Scalable Nernst thermoelectric power using a coiled galfenol wire

    NASA Astrophysics Data System (ADS)

    Yang, Zihao; Codecido, Emilio A.; Marquez, Jason; Zheng, Yuanhua; Heremans, Joseph P.; Myers, Roberto C.

    2017-09-01

    The Nernst thermopower usually is considered far too weak in most metals for waste heat recovery. However, its transverse orientation gives it an advantage over the Seebeck effect on non-flat surfaces. Here, we experimentally demonstrate the scalable generation of a Nernst voltage in an air-cooled metal wire coiled around a hot cylinder. In this geometry, a radial temperature gradient generates an azimuthal electric field in the coil. A Galfenol (Fe0.85Ga0.15) wire is wrapped around a cartridge heater, and the voltage drop across the wire is measured as a function of axial magnetic field. As expected, the Nernst voltage scales linearly with the length of the wire. Based on heat conduction and fluid dynamic equations, finite-element method is used to calculate the temperature gradient across the Galfenol wire and determine the Nernst coefficient. A giant Nernst coefficient of -2.6 μV/KT at room temperature is estimated, in agreement with measurements on bulk Galfenol. We expect that the giant Nernst effect in Galfenol arises from its magnetostriction, presumably through enhanced magnon-phonon coupling. Our results demonstrate the feasibility of a transverse thermoelectric generator capable of scalable output power from non-flat heat sources.

  16. Silicon Carbide Diodes Performance Characterization at High Temperatures

    NASA Technical Reports Server (NTRS)

    Lebron-Velilla, Ramon C.; Schwarze, Gene E.; Gardner, Brent G.; Adams, Jerry

    2004-01-01

    NASA Glenn Research center's Electrical Systems Development branch is working to demonstrate and test the advantages of Silicon Carbide (SiC) devices in actual power electronics applications. The first step in this pursuit is to obtain commercially available SiC Schottky diodes and to individually test them under both static and dynamic conditions, and then compare them with current state of the art silicon Schottky and ultra fast p-n diodes of similar voltage and current ratings. This presentation covers the results of electrical tests performed at NASA Glenn. Steady state forward and reverse current-volt (I-V) curves were generated for each device to compare performance and to measure their forward voltage drop at rated current, as well as the reverse leakage current at rated voltage. In addition, the devices were individually connected as freewheeling diodes in a Buck (step down) DC to DC converter to test their reverse recovery characteristics and compare their transient performance in a typical converter application. Both static and transient characterization tests were performed at temperatures ranging from 25 C to 300 C, in order to test and demonstrate the advantages of SiC over Silicon at high temperatures.

  17. Fabrication and investigation of electrochromatographic columns with a simplex configuration.

    PubMed

    Liu, Qing; Yang, Lijun; Wang, Qiuquan; Zhang, Bo

    2014-07-04

    Duplex capillary columns with a packed and an open section are widely used in electrochromatography (CEC). The duplex column configuration leads to non-uniform voltage drop, electrical field distribution and separation performance. It also adds to the complexity in understanding and optimizing electrochromatographic process. In this study, we introduced a simplex column configuration based on single particle fritting technology. The new column configuration has an essentially uniform packed bed through the entire column length, with only 1mm length left unpacked serving as the optical detection window. The study shows that a simplex column has higher separation efficiency than a duplex column, especially at the high voltage range, due to the consistent distribution of electrical field over the column length. In comparison to the duplex column, the simplex column presented a lower flow rate at the same applied voltage, suggesting that an open section may support a higher speed than a packed section. In practice, the long and short ends of the simplex column could be used as independent CEC columns respectively. This "two-in-one" bi-functional column configuration provided extra flexibilities in selecting and optimizing electrochromatographic conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Differential CMOS Sub-Terahertz Detector with Subthreshold Amplifier.

    PubMed

    Yang, Jong-Ryul; Han, Seong-Tae; Baek, Donghyun

    2017-09-09

    We propose a differential-type complementary metal-oxide-semiconductor (CMOS) sub-terahertz (THz) detector with a subthreshold preamplifier. The proposed detector improves the voltage responsivity and effective signal-to-noise ratio (SNR) using the subthreshold preamplifier, which is located between the differential detector device and main amplifier. The overall noise of the detector for the THz imaging system is reduced by the preamplifier because it diminishes the noise contribution of the main amplifier. The subthreshold preamplifier is self-biased by the output DC voltage of the detector core and has a dummy structure that cancels the DC offsets generated by the preamplifier itself. The 200 GHz detector fabricated using 0.25 μm CMOS technology includes a low drop-out regulator, current reference blocks, and an integrated antenna. A voltage responsivity of 2020 kV/W and noise equivalent power of 76 pW/√Hz are achieved using the detector at a gate bias of 0.5 V, respectively. The effective SNR at a 103 Hz chopping frequency is 70.9 dB with a 0.7 W/m² input signal power density. The dynamic range of the raster-scanned THz image is 44.59 dB.

  19. Differential CMOS Sub-Terahertz Detector with Subthreshold Amplifier

    PubMed Central

    Han, Seong-Tae; Baek, Donghyun

    2017-01-01

    We propose a differential-type complementary metal-oxide-semiconductor (CMOS) sub-terahertz (THz) detector with a subthreshold preamplifier. The proposed detector improves the voltage responsivity and effective signal-to-noise ratio (SNR) using the subthreshold preamplifier, which is located between the differential detector device and main amplifier. The overall noise of the detector for the THz imaging system is reduced by the preamplifier because it diminishes the noise contribution of the main amplifier. The subthreshold preamplifier is self-biased by the output DC voltage of the detector core and has a dummy structure that cancels the DC offsets generated by the preamplifier itself. The 200 GHz detector fabricated using 0.25 μm CMOS technology includes a low drop-out regulator, current reference blocks, and an integrated antenna. A voltage responsivity of 2020 kV/W and noise equivalent power of 76 pW/√Hz are achieved using the detector at a gate bias of 0.5 V, respectively. The effective SNR at a 103 Hz chopping frequency is 70.9 dB with a 0.7 W/m2 input signal power density. The dynamic range of the raster-scanned THz image is 44.59 dB. PMID:28891927

  20. Soft-short management and remediation in 10-year-old NiCds in Geo orbit

    NASA Technical Reports Server (NTRS)

    Flordeliza, Nicanor A.; Bounds, Ronald W.

    1996-01-01

    After 10 years in Geo orbit, during the spring 1993 eclipse season, soft shorts occurred in cells of two of the three batteries on the F2R spacecraft On battery #1, the cell soft short turned suddenly into a hard short; the resulting sudden 1.2V fall in battery voltage and rise in temperature was observed via telemetry. On battery #3, the deleterious impact of its soft short increased day by day, manifesting itself as a drop in battery voltage part-way through each eclipse, causing high loading on the remaining good battery. This paper reports how by planned charge management, including applying (against-the-book) overcharge ratios (C/D) exceeding 1.75, the battery #3 cell soft short was 'built down' until the cell voltage fade ceased. The problem with the battery #3 soft-shorted cell was fought with partial success throughout the latter half of the fall 93 season, and the lessons learned were applied to alleviate the problem during the spring 94 and fall 94 eclipse seasons. The life of the spacecraft was successfully prolonged until it was retired in March 1995.

  1. Mechanism of the entire overdischarge process and overdischarge-induced internal short circuit in lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Guo, Rui; Lu, Languang; Ouyang, Minggao; Feng, Xuning

    2016-07-01

    Lithium-ion batteries connected in series are prone to be overdischarged. Overdischarge results in various side effects, such as capacity degradation and internal short circuit (ISCr). However, most of previous research on the overdischarge of a cell was terminated when the cell voltage dropped to 0 V, leaving the further impacts of overdischarge unclear. This paper investigates the entire overdischarge process of large-format lithium-ion batteries by discharging the cell to -100% state of charge (SOC). A significant voltage platform is observed at approximately -12% SOC, and ISCr is detected after the cell is overdischarged when passing the platform. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) results indicate that the overdischarge-induced ISCr is caused by Cu deposition on electrodes, suggesting possible Cu collector dissolution at the voltage platform near -12% SOC. A prognostic/mechanistic model considering ISCr is used to evaluate the resistance of ISCr (RISCr), the value of which decreases sharply at the beginning of ISCr formation. Inducing the ISCr by overdischarge is effective and well controlled without any mechanical deformation or the use of a foreign substance.

  2. An analog RF gap voltage regulation system for the Advanced Photon Source storage ring.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horan, D.

    1999-04-13

    An analog rf gap voltage regulation system has been designed and built at Argonne National Laboratory to maintain constant total storage ring rf gap voltage, independent of beam loading and cavity tuning effects. The design uses feedback control of the klystron mod-anode voltage to vary the amount of rf power fed to the storage ring cavities. The system consists of two independent feedback loops, each regulating the combined rf gap voltages of eight storage ring cavities by varying the output power of either one or two rf stations, depending on the mode of operation. It provides full operator control andmore » permissive logic to permit feedback control of the rf system output power only if proper conditions are met. The feedback system uses envelope-detected cavity field probe outputs as the feedback signal. Two different methods of combining the individual field probe signals were used to generate a relative DC level representing one-half of the total storage ring rf voltage, an envelope-detected vector sum of the field probe rf signals, and the DC sum of individual field probe envelope detector outputs. The merits of both methods are discussed. The klystron high-voltage power supply (HVPS) units are fitted with an analog interface for external control of the mod-anode voltage level, using a four-quadrant analog multiplier to modulate the HVPS mod-anode voltage regulator set-point in response to feedback system commands.« less

  3. Electrostatic Discharge Properties of Irradiated Nanocomposites

    DTIC Science & Technology

    2009-03-01

    47 24. Example Plot of Mean Current vs . Voltage Difference Curves ..................................48 25...across dielectric surfaces and prevent ESD arcing to very high voltage differentials (Figure 2) [7]. All of these drastic alterations in material...structure currents (3) Area thickness and dielectric strength of the material (4) Total charge involved in the event (5) Breakdown voltage (6) Current

  4. Power conditioning using dynamic voltage restorers under different voltage sag types.

    PubMed

    Saeed, Ahmed M; Abdel Aleem, Shady H E; Ibrahim, Ahmed M; Balci, Murat E; El-Zahab, Essam E A

    2016-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  5. Power conditioning using dynamic voltage restorers under different voltage sag types

    PubMed Central

    Saeed, Ahmed M.; Abdel Aleem, Shady H.E.; Ibrahim, Ahmed M.; Balci, Murat E.; El-Zahab, Essam E.A.

    2015-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type. PMID:26843975

  6. Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Xiangqi; Wang, Jiyu; Mulcahy, David

    This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different casemore » studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.« less

  7. Space Shuttle Solid Rocket Booster decelerator subsystem - Air drop test vehicle/B-52 design

    NASA Technical Reports Server (NTRS)

    Runkle, R. E.; Drobnik, R. F.

    1979-01-01

    The air drop development test program for the Space Shuttle Solid Rocket Booster Recovery System required the design of a large drop test vehicle that would meet all the stringent requirements placed on it by structural loads, safety considerations, flight recovery system interfaces, and sequence. The drop test vehicle had to have the capability to test the drogue and the three main parachutes both separately and in the total flight deployment sequence and still be low-cost to fit in a low-budget development program. The design to test large ribbon parachutes to loads of 300,000 pounds required the detailed investigation and integration of several parameters such as carrier aircraft mechanical interface, drop test vehicle ground transportability, impact point ground penetration, salvageability, drop test vehicle intelligence, flight design hardware interfaces, and packaging fidelity.

  8. Electrodynamics panel presentation

    NASA Technical Reports Server (NTRS)

    Mccoy, J.

    1986-01-01

    The Plasma Motor Generator (PMG) concept is explained in detail. The PMG tether systems being used to calculate the estimated performance data is described. The voltage drops and current contact geometries involved in the operation of an electrodynamic tether are displayed illustrating the comparative behavior of hollow cathodes, electron guns, and passive collectors for current coupling into the ionosphere. The basic PMG design involving the massive tether cable with little or no satellite mass at the far end(s) are also described. The Jupiter mission and its use of electrodynamic tethers are given. The need for demonstration experiments is stressed.

  9. Millimeter-Wave Circuit Analysis and Synthesis.

    DTIC Science & Technology

    1985-05-01

    correct within a few percent and the resulting drain-source t.r7njnal current is usually high by approximately 10 percent. -20- Before Eqs. 5 and 9 can...typically used in arialytic FET models and is correct in the limit of long gates.1-3 With this approximation, the voltage drop across the depletion layer...carried out for two ba. c geometrica ss- ft WI sa of arbitrary thickness place-i c;c:.slc,, wi’ta -v .h each sidewall and (2) a thin Yl, s 1 te w~ith

  10. The possible equilibrium shapes of static pendant drops

    NASA Astrophysics Data System (ADS)

    Sumesh, P. T.; Govindarajan, Rama

    2010-10-01

    Analytical and numerical studies are carried out on the shapes of two-dimensional and axisymmetric pendant drops hanging under gravity from a solid surface. Drop shapes with both pinned and equilibrium contact angles are obtained naturally from a single boundary condition in the analytical energy optimization procedure. The numerical procedure also yields optimum energy shapes, satisfying Young's equation without the explicit imposition of a boundary condition at the plate. It is shown analytically that a static pendant two-dimensional drop can never be longer than 3.42 times the capillary length. A related finding is that a range of existing solutions for long two-dimensional drops correspond to unphysical drop shapes. Therefore, two-dimensional drops of small volume display only one static solution. In contrast, it is known that axisymmetric drops can display multiple solutions for a given volume. We demonstrate numerically that there is no limit to the height of multiple-lobed Kelvin drops, but the total volume is finite, with the volume of successive lobes forming a convergent series. The stability of such drops is in question, though. Drops of small volume can attain large heights. A bifurcation is found within the one-parameter space of Laplacian shapes, with a range of longer drops displaying a minimum in energy in the investigated space. Axisymmetric Kelvin drops exhibit an infinite number of bifurcations.

  11. Nano-Composite Foam Sensor System in Football Helmets.

    PubMed

    Merrell, A Jake; Christensen, William F; Seeley, Matthew K; Bowden, Anton E; Fullwood, David T

    2017-12-01

    American football has both the highest rate of concussion incidences as well as the highest number of concussions of all contact sports due to both the number of athletes and nature of the sport. Recent research has linked concussions with long term health complications such as chronic traumatic encephalopathy and early onset Alzheimer's. Understanding the mechanical characteristics of concussive impacts is critical to help protect athletes from these debilitating diseases and is now possible using helmet-based sensor systems. To date, real time on-field measurement of head impacts has been almost exclusively measured by devices that rely on accelerometers or gyroscopes attached to the player's helmet, or embedded in a mouth guard. These systems monitor motion of the head or helmet, but do not directly measure impact energy. This paper evaluates the accuracy of a novel, multifunctional foam-based sensor that replaces a portion of the helmet foam to measure impact. All modified helmets were tested using a National Operating Committee Standards for Athletic Equipment-style drop tower with a total of 24 drop tests (4 locations with 6 impact energies). The impacts were evaluated using a headform, instrumented with a tri-axial accelerometer, mounted to a Hybrid III neck assembly. The resultant accelerations were evaluated for both the peak acceleration and the severity indices. These data were then compared to the voltage response from multiple Nano Composite Foam sensors located throughout the helmet. The foam sensor system proved to be accurate in measuring both the HIC and Gadd severity index, as well as peak acceleration while also providing additional details that were previously difficult to obtain, such as impact energy.

  12. A mathematical approach for evaluating nickel-hydrogen cells

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.

    1986-01-01

    A mathematical equation is presented which gives a quantitative relationship between time-voltage discharge curves, when a cell's ampere-hour capacity is determined at a constant discharge current. In particular the equation quantifies the initial exponential voltage decay; the rate of voltage decay; the overall voltage shift of the curve and the total capacity of the cell at the given discharge current. The results of 12 nickel-hydrogen boiler plate cells cycled to 80 percent depth-of-discharge (DOD) are discussed in association with these equations.

  13. Ion extraction capabilities of two-grid accelerator systems. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Rovang, D. C.; Wilbur, P. J.

    1984-01-01

    An experimental investigation into the ion extraction capabilities of two-grid accelerator systems common to electrostatic ion thrusters is described. This work resulted in a large body of experimental data which facilitates the selection of the accelerator system geometries and operating parameters necessary to maximize the extracted ion current. Results suggest that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 0.5 mm. Impingement-limited performance is shown to depend most strongly on grid separation distance, accelerator hole diameter ratio, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained at small grid separation ratios suggest a new grid operating condition where high beam current per hole levels are achieved at a specified net accelerating voltage. It is shown that this operating condition is realized at an optimum ratio of net-to-total accelerating voltage ratio which is typically quite high. The apparatus developed for this study is also shown to be well suited measuring the electron backstreaming and electrical breakdown characteristics of two-grid accelerator systems.

  14. Addressing On-Chip Power Converstion and Dissipation Issues in Many-Core System-on-a-Chip Based on Conventional Silicon and Emerging Nanotechnologies

    NASA Astrophysics Data System (ADS)

    Ashenafi, Emeshaw

    Integrated circuits (ICs) are moving towards system-on-a-chip (SOC) designs. SOC allows various small and large electronic systems to be implemented in a single chip. This approach enables the miniaturization of design blocks that leads to high density transistor integration, faster response time, and lower fabrication costs. To reap the benefits of SOC and uphold the miniaturization of transistors, innovative power delivery and power dissipation management schemes are paramount. This dissertation focuses on on-chip integration of power delivery systems and managing power dissipation to increase the lifetime of energy storage elements. We explore this problem from two different angels: On-chip voltage regulators and power gating techniques. On-chip voltage regulators reduce parasitic effects, and allow faster and efficient power delivery for microprocessors. Power gating techniques, on the other hand, reduce the power loss incurred by circuit blocks during standby mode. Power dissipation (Ptotal = Pstatic and Pdynamic) in a complementary metal-oxide semiconductor (CMOS) circuit comes from two sources: static and dynamic. A quadratic dependency on the dynamic switching power and a more than linear dependency on static power as a form of gate leakage (subthreshold current) exist. To reduce dynamic power loss, the supply power should be reduced. A significant reduction in power dissipation occurs when portions of a microprocessor operate at a lower voltage level. This reduction in supply voltage is achieved via voltage regulators or converters. Voltage regulators are used to provide a stable power supply to the microprocessor. The conventional off-chip switching voltage regulator contains a passive floating inductor, which is difficult to be implemented inside the chip due to excessive power dissipation and parasitic effects. Additionally, the inductor takes a very large chip area while hampering the scaling process. These limitations make passive inductor based on-chip regulator design very unattractive for SOC integration and multi-/many-core environments. To circumvent the challenges, three alternative techniques based on active circuit elements to replace the passive LC filter of the buck convertor are developed. The first inductorless on-chip switching voltage regulator architecture is based on a cascaded 2nd order multiple feedback (MFB) low-pass filter (LPF). This design has the ability to modulate to multiple voltage settings via pulse-with modulation (PWM). The second approach is a supplementary design utilizing a hybrid low drop-out scheme to lower the output ripple of the switching regulator over a wider frequency range. The third design approach allows the integration of an entire power management system within a single chipset by combining a highly efficient switching regulator with an intermittently efficient linear regulator (area efficient), for robust and highly efficient on-chip regulation. The static power (Pstatic) or subthreshold leakage power (Pleak) increases with technology scaling. To mitigate static power dissipation, power gating techniques are implemented. Power gating is one of the popular methods to manage leakage power during standby periods in low-power high-speed IC design. It works by using transistor based switches to shut down part of the circuit block and put them in the idle mode. The efficiency of a power gating scheme involves minimum Ioff and high Ion for the sleep transistor. A conventional sleep transistor circuit design requires an additional header, footer, or both switches to turn off the logic block. This additional transistor causes signal delay and increases the chip area. We propose two innovative designs for next generation sleep transistor designs. For an above threshold operation, we present a sleep transistor design based on fully depleted silicon-on-insulator (FDSOI) device. For a subthreshold circuit operation, we implement a sleep transistor utilizing the newly developed silicon-on-ferroelectric-insulator field effect transistor (SOFFET). In both of the designs, the ability to control the threshold voltage via bias voltage at the back gate makes both devices more flexible for sleep transistors design than a bulk MOSFET. The proposed approaches simplify the design complexity, reduce the chip area, eliminate the voltage drop by sleep transistor, and improve power dissipation. In addition, the design provides a dynamically controlled Vt for times when the circuit needs to be in a sleep or switching mode.

  15. Regulation of a lightweight high efficiency capacitator diode voltage multiplier dc-dc converter

    NASA Technical Reports Server (NTRS)

    Harrigill, W. T., Jr.; Myers, I. T.

    1976-01-01

    A method for the regulation of a capacitor diode voltage multiplier dc-dc converter has been developed which has only minor penalties in weight and efficiency. An auxiliary inductor is used, which only handles a fraction of the total power, to control the output voltage through a pulse width modulation method in a buck boost circuit.

  16. Transforaminal Endoscopic Decompression for Foot Drop Twelve Years After Lumbar Total Disc Replacment: Technical Note.

    PubMed

    Telfeian, Albert E; Oyelese, Adetokunbo; Fridley, Jared; Gokaslan, Ziya L

    2018-05-19

    Lumbar total disc replacement (LTDR) is considered for the treatment of lumbar degenerative disc disease with the hope that by preserving motion the long-term fusion complication of adjacent segment disease can be avoided. The complications of LTDR can be divided into approach-related and long-term complications. Very little has been described about the complications and treatment for complications more than 10 years after the device has been implanted. Here we describe a tranforaminal endoscopic discectomy procedure for a patient presenting with foot drop twelve years after a L5-S1 total disc replacement. Copyright © 2018. Published by Elsevier Inc.

  17. SABRE modification to a higher voltage high impedance inductive voltage adder (IVA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazarakis, M.G.; Smith, D.L.; Poukey, J.W.

    The SABRE accelerator was originally designed to operate as low impedance voltage adder with 40-ohm maximum output impedance in negative polarity operation and approximately 20 ohm in positive polarity. Because of the low impedance and higher than expected energy losses in the pulse forming network, the operating input cavity voltage is of the order of 800 kV which limits the total output voltage to {approximately} 8 MV for negative polarity and 5 to 6 MV for positive polarity. The modifications presented here aim to increase the output voltage in both polarities. A new high impedance central electrode was designed capablemore » of operating both in negative and positive polarities, and the number of pulse forming lines feeding the inductively isolated cavities was reduced to half. These modifications were recently tested in positive polarity. An increase in the total accelerating voltage from 5.5 MV to 9 MV was observed while stressing all components to the level required to achieve 12 MV in negative polarity. In these experiments only 65% of the usual operating intermediate store capacitor voltage was necessary (1.7 MV instead of 2.6 MV). Currently, the device is reconfigured for negative polarity tests. The cavities are rotated by 180{degree} and a 17-inch spool is added at the base of the cantilevered center electrode (cathode electrode). Positive and negative polarity results are presented and compared with simulations.« less

  18. Stress drop with constant, scale independent seismic efficiency and overshoot

    USGS Publications Warehouse

    Beeler, N.M.

    2001-01-01

    To model dissipated and radiated energy during earthquake stress drop, I calculate dynamic fault slip using a single degree of freedom spring-slider block and a laboratory-based static/kinetic fault strength relation with a dynamic stress drop proportional to effective normal stress. The model is scaled to earthquake size assuming a circular rupture; stiffness varies inversely with rupture radius, and rupture duration is proportional to radius. Calculated seismic efficiency, the ratio of radiated to total energy expended during stress drop, is in good agreement with laboratory and field observations. Predicted overshoot, a measure of how much the static stress drop exceeds the dynamic stress drop, is higher than previously published laboratory and seismic observations and fully elasto-dynamic calculations. Seismic efficiency and overshoot are constant, independent of normal stress and scale. Calculated variation of apparent stress with seismic moment resembles the observational constraints of McGarr [1999].

  19. Self-focused acoustic ejectors for viscous liquids.

    PubMed

    Hon, S F; Kwok, K W; Li, H L; Ng, H Y

    2010-06-01

    Self-focused acoustic ejectors using the Fresnel zone plate (FZP) have been developed for ejecting viscous liquids, without nozzle, in the drop-on-demand mode. The FZP is composed of a lead zirconate titanate piezoelectric plate patterned with a series of annular electrodes, with the unelectroded region of the plate removed. Our results show that the acoustic waves are effectively self-focused by constructive interference in glycerin (with a viscosity of 1400 mPa s), giving small focal points with a high pressure. Due to the high attenuation, the wave pressure decreases significantly with the distance from the FZP. Nevertheless, the pressure at the focal points 2.5 and 6.5 mm from the FZP is high enough to eject glycerin droplets in the drop-on-demand mode. Driven by a simple wave train comprising a series of sinusoidal voltages with an amplitude of 35 V, a frequency of 4.28 MHz, and a duration of 2 ms, the ejector can eject fine glycerin droplets with a diameter of 0.4 mm at a repetition frequency of 120 Hz in a downward direction. Droplets of other viscous liquids, such as the prepolymer of an epoxy with a viscosity of 2000 mPa s, can also be ejected in the drop-on-demand mode under similar conditions.

  20. Competitive behavior of photons contributing to junction voltage jump in narrow band-gap semiconductor multi-quantum-well laser diodes at lasing threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Liefeng, E-mail: fengliefeng@tju.edu.cn, E-mail: lihongru@nankai.edu.cn; Yang, Xiufang; Wang, Cunda

    2015-04-15

    The junction behavior of different narrow band-gap multi-quantum-well (MQW) laser diodes (LDs) confirmed that the jump in the junction voltage in the threshold region is a general characteristic of narrow band-gap LDs. The relative change in the 1310 nm LD is the most obvious. To analyze this sudden voltage change, the threshold region is divided into three stages by I{sub th}{sup l} and I{sub th}{sup u}, as shown in Fig. 2; I{sub th}{sup l} is the conventional threshold, and as long as the current is higher than this threshold, lasing exists and the IdV/dI-I plot drops suddenly; I{sub th}{sup u}more » is the steady lasing point, at which the separation of the quasi-Fermi levels of electron and holes across the active region (V{sub j}) is suddenly pinned. Based on the evolutionary model of dissipative structure theory, the rate equations of the photons in a single-mode LD were deduced in detail at I{sub th}{sup l} and I{sub th}{sup u}. The results proved that the observed behavior of stimulated emission suddenly substituting for spontaneous emission, in a manner similar to biological evolution, must lead to a sudden increase in the injection carriers in the threshold region, which then causes the sudden increase in the junction voltage in this region.« less

  1. Quench dynamics in superconducting nanojunctions: Metastability and dynamical Yang-Lee zeros

    NASA Astrophysics Data System (ADS)

    Souto, R. Seoane; Martín-Rodero, A.; Yeyati, A. Levy

    2017-10-01

    We study the charge transfer dynamics following the formation of a phase or voltage biased superconducting nanojunction using a full counting statistics analysis. We demonstrate that the evolution of the zeros of the generating function allows one to identify the population of different many body states much in the same way as the accumulation of Yang-Lee zeros of the partition function in equilibrium statistical mechanics is connected to phase transitions. We give an exact expression connecting the dynamical zeros to the charge transfer cumulants and discuss when an approximation based on "dominant" zeros is valid. We show that, for generic values of the parameters, the system gets trapped into a metastable state characterized by a nonequilibrium population of the many body states which is dependent on the initial conditions. We study in particular the effect of the switching rates in the dynamics showing that, in contrast to intuition, the deviation from thermal equilibrium increases for the slower rates. In the voltage biased case the steady state is reached independent of the initial conditions. Our method allows us to obtain accurate results for the steady state current and noise in quantitative agreement with steady state methods developed to describe the multiple Andreev reflections regime. Finally, we discuss the system dynamics after a sudden voltage drop showing the possibility of tuning the many body states population by an appropriate choice of the initial voltage, providing a feasible experimental way to access the quench dynamics and control the state of the system.

  2. Ultra high voltage MOS controlled 4H-SiC power switching devices

    NASA Astrophysics Data System (ADS)

    Ryu, S.; Capell, C.; Van Brunt, E.; Jonas, C.; O'Loughlin, M.; Clayton, J.; Lam, K.; Pala, V.; Hull, B.; Lemma, Y.; Lichtenwalner, D.; Zhang, Q. J.; Richmond, J.; Butler, P.; Grider, D.; Casady, J.; Allen, S.; Palmour, J.; Hinojosa, M.; Tipton, C. W.; Scozzie, C.

    2015-08-01

    Ultra high voltage (UHV, >15 kV) 4H-silicon carbide (SiC) power devices have the potential to significantly improve the system performance, reliability, and cost of energy conversion systems by providing reduced part count, simplified circuit topology, and reduced switching losses. In this paper, we compare the two MOS based UHV 4H-SiC power switching devices; 15 kV 4H-SiC MOSFETs and 15 kV 4H-SiC n-IGBTs. The 15 kV 4H-SiC MOSFET shows a specific on-resistance of 204 mΩ cm2 at 25 °C, which increased to 570 mΩ cm2 at 150 °C. The 15 kV 4H-SiC MOSFET provides low, temperature-independent, switching losses which makes the device more attractive for applications that require higher switching frequencies. The 15 kV 4H-SiC n-IGBT shows a significantly lower forward voltage drop (VF), along with reasonable switching performance, which make it a very attractive device for high voltage applications with lower switching frequency requirements. An electrothermal analysis showed that the 15 kV 4H-SiC n-IGBT outperforms the 15 kV 4H-SiC MOSFET for applications with switching frequencies of less than 5 kHz. It was also shown that the use of a carrier storage layer (CSL) can significantly improve the conduction performance of the 15 kV 4H-SiC n-IGBTs.

  3. An accurate MOS measurement procedure for work function difference in the Al/SiO 2/Si system

    NASA Astrophysics Data System (ADS)

    Krautschneider, W. H.; Laschinski, J.; Seifert, W.; Wagemann, H. G.

    1986-05-01

    Determination of Al/Si work function difference φMS is achieved by means of capacitance measurements of differently manufactured MOS varactors (Al/SiO 2/ n-Si) with variable oxide thickness ("step varactor"). For the φMS evaluation the influences of interface (fQ it) and oxide (ifQ f) charges have been considered, and models of their charges and dipole behaviour are described. Midgap band bending has been chosen as best condition for the evaluation of ΦMSO as basic amount of work function difference with negligible interference of Qit. Plots of Φ MSvs ψS for numerous specimens indicate that, usually, dipole voltage ΔΦ is closely connected to ΦMS within the voltage drop across the MOS varactor according to ΦMS = ΦMSO + qΔΦ. For the evaluation of dipole voltage ΔΦ models of charge density Qit within interface states are presented which assume dominating donor or acceptor states within the two halves of the band gap. Corrections of impurity homogeneity across the wafer and of impurity profile into the depth of the chips are considered. For the work function difference extrapolated to intrinsic density, ΦMSO = (-0.26 ± 0.05) eV holds. Additionally from midgap through inversion of n-Si, dipole voltage was observed ( ΔΦ = 0.015 V) which was caused by interface states and oxide charge 3 nm apart from one another.

  4. Electrical breakdown detection system for dielectric elastomer actuators

    NASA Astrophysics Data System (ADS)

    Ghilardi, Michele; Busfield, James J. C.; Carpi, Federico

    2017-04-01

    Electrical breakdown of dielectric elastomer actuators (DEAs) is an issue that has to be carefully addressed when designing systems based on this novel technology. Indeed, in some systems electrical breakdown might have serious consequences, not only in terms of interruption of the desired function but also in terms of safety of the overall system (e.g. overheating and even burning). The risk for electrical breakdown often cannot be completely avoided by simply reducing the driving voltages, either because completely safe voltages might not generate sufficient actuation or because internal or external factors might change some properties of the actuator whilst in operation (for example the aging or fatigue of the material, or an externally imposed deformation decreasing the distance between the compliant electrodes). So, there is the clear need for reliable, simple and cost-effective detection systems that are able to acknowledge the occurrence of a breakdown event, making DEA-based devices able to monitor their status and become safer and "selfaware". Here a simple solution for a portable detection system is reported that is based on a voltage-divider configuration that detects the voltage drop at the DEA terminals and assesses the occurrence of breakdown via a microcontroller (Beaglebone Black single-board computer) combined with a real-time, ultra-low-latency processing unit (Bela cape an open-source embedded platform developed at Queen Mary University of London). The system was used to both generate the control signal that drives the actuator and constantly monitor the functionality of the actuator, detecting any breakdown event and discontinuing the supplied voltage accordingly, so as to obtain a safer controlled actuation. This paper presents preliminary tests of the detection system in different scenarios in order to assess its reliability.

  5. Electromagnetic DM technology meets future AO demands

    NASA Astrophysics Data System (ADS)

    Hamelinck, Roger; Rosielle, Nick; Steinbuch, Maarten; Doelman, Niek

    New deformable mirror technology is developed by the Technische Universiteit Eindhoven, Delft University of Technology and TNO Science and Industry. Several prototype adaptive deformable mirrors are realized mirrors, up to 427 actuators and ∅150mm diameter, with characteristics suitable for future AO systems. The prototypes consist of a 100µm thick, continuous facesheet on which low voltage, electromagnetic, push-pull actuators impose out-of-plane displacements. The variable reluctance actuators with ±10µm stroke and nanometer resolution are located in a standard actuator module. Each module with 61 actuators connects to a single PCB with dedicated, 16 bit, PWM based, drivers. A LVDS multi-drop cable connects up to 32 actuator modules. With the actuator module, accompanying PCB and multi-drop system the deformable mirror technology is made modular in its mechanics and electronics. An Ethernet-LVDS bridge enables any commercial PC to control the mirror using the UDP standard. Latest results of the deformable mirror technology development are presented.

  6. A numerical study on electrochemical transport of ions in calcium fluoride slag

    NASA Astrophysics Data System (ADS)

    Karimi-Sibaki, E.; Kharicha, A.; Wu, M.; Ludwig, A.

    2016-07-01

    Electrically resistive CaF 2-based slags are widely used in electroslag remelting (ESR) process to generate Joule heat for the melting of electrode. The electric current is conducted by ions (electrolyte) such as Ca +2 or F -, thus it is necessary to establish electrochemical models to study electrical behavior of slag. This paper presents a numerical model on electrochemical transport of ions in an arbitrary symmetrical (ZZ) and non-symmetrical (CaF2) stagnant electrolytes blocked by two parallel, planar electrodes. The dimensionless Poisson-Nernst-Planck (PNP) equations are solved to model electro-migration and diffusion of ions. The ions are considered to be inert that no Faradic reactions occur. Spatial variations of concentrations of ions, charge density and electric potential across the electrolyte are analyzed. It is shown that the applied potential has significant influence on the system response. At high applied voltage, the anodic potential drop near the electrode is significantly larger than cathodic potential drop in fully dissociated CaF2 electrolyte.

  7. Dependence of Seebeck coefficient on a load resistance and energy conversion efficiency in a thermoelectric composite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamashita, Osamu; Odahara, Hirotaka; Ochi, Takahiro

    2007-10-02

    The thermo-emf {delta}V and current {delta}I generated by imposing the alternating temperature gradients (ATG) at a period of T and the steady temperature gradient (STG) on a thermoelectric (TE) composite were measured as a function of t, where t is the lapsed time and T was varied from 60 to or {infinity} s. The STG and ATG were produced by imposing steadily and alternatively a source voltage V in the range from 1.0 to 4.0 V on two Peltier modules sandwiching a composite. {delta}T, {delta}V, {delta}I and V{sub P} oscillate at a period T and their waveforms vary significantly withmore » a change of T, where {delta}V and V{sub P} are the voltage drops in a load resistance R{sub L} and in resistance R{sub P} of two modules. The resultant Seebeck coefficient |{alpha}| = |{delta}V|/{delta}T of a composite under the STG was found to be expressed as |{alpha}| = |{alpha}{sub 0}|(1 - R{sub comp}/R{sub T}), where R{sub T} is the total resistance of a circuit for measuring the output signals and R{sub comp} is the resistance of a composite. The effective generating power {delta}W{sub eff} has a local maximum at T = 960 s for the p-type composite and at T = 480 s for the n-type one. The maximum energy conversion efficiency {eta} of the p- and n-type composites under the ATG produced by imposing a voltage of 4.0 V at an optimum period were 0.22 and 0.23% at {delta}T{sub eff} = 50 K, respectively, which are 42 and 43% higher than those at {delta}T = 42 K under the STG. These maximum {eta} for a TE composite sandwiched between two Peltier modules, were found to be expressed theoretically in terms of R{sub P}, R{sub T}, R{sub L}, {alpha}{sub P} and {alpha}, where {alpha}{sub P} and {alpha} are the resultant Seebeck coefficients of Peltier modules and a TE composite.« less

  8. Development of multichannel MEG system at IGCAR

    NASA Astrophysics Data System (ADS)

    Mariyappa, N.; Parasakthi, C.; Gireesan, K.; Sengottuvel, S.; Patel, Rajesh; Janawadkar, M. P.; Radhakrishnan, T. S.; Sundar, C. S.

    2013-02-01

    We describe some of the challenging aspects in the indigenous development of the whole head multichannel magnetoencephalography (MEG) system at IGCAR, Kalpakkam. These are: i) fabrication and testing of a helmet shaped sensor array holder of a polymeric material experimentally tested to be compatible with liquid helium temperatures, ii) the design and fabrication of the PCB adapter modules, keeping in mind the inter-track cross talk considerations between the electrical leads used to provide connections from SQUID at liquid helium temperature (4.2K) to the electronics at room temperature (300K) and iii) use of high resistance manganin wires for the 86 channels (86×8 leads) essential to reduce the total heat leak which, however, inevitably causes an attenuation of the SQUID output signal due to voltage drop in the leads. We have presently populated 22 of the 86 channels, which include 6 reference channels to reject the common mode noise. The whole head MEG system to cover all the lobes of the brain will be progressively assembled when other three PCB adapter modules, presently under fabrication, become available. The MEG system will be used for a variety of basic and clinical studies including localization of epileptic foci during pre-surgical mapping in collaboration with neurologists.

  9. Characteristics of back corona discharge in a honeycomb catalyst and its application for treatment of volatile organic compounds.

    PubMed

    Feng, Fada; Zheng, Yanyan; Shen, Xinjun; Zheng, Qinzhen; Dai, Shaolong; Zhang, Xuming; Huang, Yifan; Liu, Zhen; Yan, Keping

    2015-06-02

    The main technical challenges for the treatment of volatile organic compounds (VOCs) with plasma-assisted catalysis in industrial applications are large volume plasma generation under atmospheric pressure, byproduct control, and aerosol collection. To solve these problems, a back corona discharge (BCD) configuration has been designed to evenly generate nonthermal plasma in a honeycomb catalyst. Voltage-current curves, discharge images, and emission spectra have been used to characterize the plasma. Grade particle collection results and flow field visualization in the discharge zones show not only that the particles can be collected efficiently, but also that the pressure drop of the catalyst layer is relatively low. A three-stage plasma-assisted catalysis system, comprising a dielectric barrier discharge (DBD) stage, BCD stage, and catalyst stage, was built to evaluate toluene treatment performance by BCD. The ozone analysis results indicate that BCD enhances the ozone decomposition by collecting aerosols and protecting the Ag-Mn-O catalyst downstream from aerosol contamination. The GC and FTIR results show that BCD contributes to toluene removal, especially when the specific energy input is low, and the total removal efficiency reaches almost 100%. Furthermore, this removal results in the emission of fewer byproducts.

  10. Cost of dry eye treatment in an Asian clinic setting.

    PubMed

    Waduthantri, Samanthila; Yong, Siew Sian; Tan, Chien Hua; Shen, Liang; Lee, Man Xin; Nagarajan, Sangeetha; Hla, Mynt Htoon; Tong, Louis

    2012-01-01

    To estimate the cost and patterns of expenditure of dry eye treatment. We retrieved data on the type and cost of dry eye treatment in Singapore National Eye Centre from pharmacy and clinic inventory databases over a 2 year period (2008-2009) retrospectively. According to the type of treatment, data were sorted into 7 groups; meibomien gland disease (MGD) treatment, preservative free lubricant eye drops, preserved lubricant eye drops, lubricant ointments and gels, cyclosporine eye drops, oral supplements and non-pharmacological treatments/procedures. Each recorded entry was considered as one patient episode (PE). Comparisons in each group between two years were carried out using Pearson Chi-Square test. Significance level was set at alpha  =  0.05. Cost data from 54,052 patients were available for analysis. Total number of recorded PEs was 132,758. Total annual expenditure on dry eye treatment for year 2008 and 2009 were US$1,509,372.20 and US$1,520,797.80 respectively. Total expenditure per PE in year 2008 and 2009 were US$22.11 and US$23.59 respectively. From 2008 to 2009, there was a 0.8% increase in total annual expenditure and 6.69% increase in expenditure per PE. Pharmacological treatment attributes to 99.2% of the total expenditure with lubricants accounting for 79.3% of the total pharmacological treatment expenditure. Total number of units purchased in preservative free lubricants, cyclosporine eye drops and MGD therapy have increased significantly (p<0.001) whereas number of units purchased in preserved lubricants and ointments/gels have reduced significantly (p<0.001) from 2008 to 2009. Dry eye imposes a significant direct burden to health care expenditure even without considering indirect costs. Health care planners should be aware that these direct costs appear to increase over the time and more so for particular types of medications. Given the limitations of socio-economic data, true societal costs of Dry eye syndrome are likely to be much higher than estimated.

  11. Pressure Profiles in a Loop Heat Pipe Under Gravity Influence

    NASA Technical Reports Server (NTRS)

    Ku, Jentung

    2015-01-01

    During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

  12. Pressure Profiles in a Loop Heat Pipe under Gravity Influence

    NASA Technical Reports Server (NTRS)

    Ku, Jentung

    2015-01-01

    During the operation of a loop heat pipe (LHP), the viscous flow induces pressure drops in various elements of the loop. The total pressure drop is equal to the sum of pressure drops in vapor grooves, vapor line, condenser, liquid line and primary wick, and is sustained by menisci at liquid and vapor interfaces on the outer surface of the primary wick in the evaporator. The menisci will curve naturally so that the resulting capillary pressure matches the total pressure drop. In ground testing, an additional gravitational pressure head may be present and must be included in the total pressure drop when LHP components are placed in a non-planar configuration. Under gravity-neutral and anti-gravity conditions, the fluid circulation in the LHP is driven solely by the capillary force. With gravity assist, however, the flow circulation can be driven by the combination of capillary and gravitational forces, or by the gravitational force alone. For a gravity-assist LHP at a given elevation between the horizontal condenser and evaporator, there exists a threshold heat load below which the LHP operation is gravity driven and above which the LHP operation is capillary force and gravity co-driven. The gravitational pressure head can have profound effects on the LHP operation, and such effects depend on the elevation, evaporator heat load, and condenser sink temperature. This paper presents a theoretical study on LHP operations under gravity-neutral, anti-gravity, and gravity-assist modes using pressure diagrams to help understand the underlying physical processes. Effects of the condenser configuration on the gravitational pressure head and LHP operation are also discussed.

  13. Study of switching transients in high frequency converters

    NASA Technical Reports Server (NTRS)

    Zinger, Donald S.; Elbuluk, Malik E.; Lee, Tony

    1993-01-01

    As the semiconductor technologies progress rapidly, the power densities and switching frequencies of many power devices are improved. With the existing technology, high frequency power systems become possible. Use of such a system is advantageous in many aspects. A high frequency ac source is used as the direct input to an ac/ac pulse-density-modulation (PDM) converter. This converter is a new concept which employs zero voltage switching techniques. However, the development of this converter is still in its infancy stage. There are problems associated with this converter such as a high on-voltage drop, switching transients, and zero-crossing detecting. Considering these problems, the switching speed and power handling capabilities of the MOS-Controlled Thyristor (MCT) makes the device the most promising candidate for this application. A complete insight of component considerations for building an ac/ac PDM converter for a high frequency power system is addressed. A power device review is first presented. The ac/ac PDM converter requires switches that can conduct bi-directional current and block bi-directional voltage. These bi-directional switches can be constructed using existing power devices. Different bi-directional switches for the converter are investigated. Detailed experimental studies of the characteristics of the MCT under hard switching and zero-voltage switching are also presented. One disadvantage of an ac/ac converter is that turn-on and turn-off of the switches has to be completed instantaneously when the ac source is at zero voltage. Otherwise shoot-through current or voltage spikes can occur which can be hazardous to the devices. In order for the devices to switch softly in the safe operating area even under non-ideal cases, a unique snubber circuit is used in each bi-directional switch. Detailed theory and experimental results for circuits using these snubbers are presented. A current regulated ac/ac PDM converter built using MCT's and IGBT's is evaluated.

  14. Domain switching kinetics in ferroelectric-resistive BiFeO3 thin film memories

    NASA Astrophysics Data System (ADS)

    Meng, Jianwei; Jiang, Jun; Geng, Wenping; Chen, Zhihui; Zhang, Wei; Jiang, Anquan

    2015-02-01

    We fabricated (00l) BiFeO3 (BFO) thin films in different growth modes on SrRuO3/SrTiO3 substrates using a pulsed laser deposition technique. X-ray diffraction patterns show an out-of-plane lattice constant of 4.03 Å and ferroelectric polarization of 82 µC/cm2 for the BFO thin film in a layer-by-layer growth mode (2D-BFO), larger than 3.96 Å and 51 µC/cm2 for the thin film in the 3D-island formation growth mode (3D-BFO). The 2D-BFO thin film at 300 K shows switchable on/off diode currents upon polarization flipping near a negative coercive voltage, which is nevertheless absent from the above 3D-BFO thin film. From a positive-up-negative-down pulse characterization technique, we measured domain switching current transients as well as polarization-voltage (Pf-Vf) hysteresis loops in both semiconducting thin films. Pf-Vf hysteresis loops after 1 µs-retention time show the preferred domain orientation pointing to bottom electrodes in a 3D-BFO thin film. The poor retention of the domains pointing to top electrodes can be improved considerably in a 2D-BFO thin film. From these measurements, we extracted domain switching time dependence of coercive voltage at temperatures of 78-300 K. From these dependences, we found coercive voltages in semiconducting ferroelectric thin films much higher than those in insulating thin films, disobeying the traditional Merz equation. Finally, an equivalent resistance model in description of free-carrier compensation of the front domain boundary charge is developed to interpret this difference. This equivalent resistance can be coincidently extracted either from domain switching time dependence of coercive voltage or from applied voltage dependence of domain switching current, which drops almost linearly with the temperature until down to 0 in a ferroelectric insulator at 78 K.

  15. Repetitive nanosecond electron accelerators type URT-1 for radiation technology

    NASA Astrophysics Data System (ADS)

    Sokovnin, S. Yu.; Balezin, M. E.

    2018-03-01

    The electron accelerator URT-1М-300 for mobile installation was created for radiation disinfecting to correct drawbacks that were found the URT-1M electron accelerator operation (the accelerating voltage up to 1 МV, repetition rate up to 300 pps, electron beam size 400 × 100 mm, the pulse width about 100 ns). Accelerator configuration was changed that allowed to reduce significantly by 20% tank volume with oil where is placed the system of formation high-voltage pulses, thus the average power of the accelerator is increased by 6 times at the expense of increase in pulses repetition rate. Was created the system of the computerized monitoring parameters (output parameters and thermal mode) and remote control of the accelerator (charge voltage, pulse repetition rate), its elements and auxiliary systems (heat of the thyratron, vacuum system), the remote control panel is connected to the installation by the fiber-optical channel, what lightens the work for service personnel. For generating an electron beam up to 400 mm wide there are used metal- ceramic] and metal-dielectric cold cathodes of several emission elements (plates) with a non-uniform distribution of the electron beam current density on the output foil ± 15%. It was found that emission drop of both type of cathodes, during the operation at the high repetition rate (100 pps) is substantial at the beginning of the process, and then proceeds rather slowly that allows for continuous operation up to 40 h. Experiments showed that linear dependence of the voltage and a signal from the pin-diode remains within the range of the charge voltage 45-65 kV. Thus, voltage increases from 690 to 950 kV, and the signal from the pin-diode - from (2,8-4,6)*104 Gy/s. It allows to select electron energy quite precisely with consideration of the radiation technology requirements.

  16. Differential inhibition of N and P/Q Ca2+ currents by 5-HT1A and 5-HT1D receptors in spinal neurons of Xenopus larvae

    PubMed Central

    Sun, Qian-Quan; Dale, Nicholas

    1998-01-01

    In whole-cell patch clamp recordings made from non-sensory neurons acutely isolated from the spinal cord of Xenopus (stage 40–42) larvae, two forms of inhibition of the high voltage-activated (HVA) Ca2+ currents were produced by 5-HT. One was voltage dependent and associated with both slowing of the activation kinetics and shifting of the voltage dependence of the HVA currents. This inhibition was relieved by strong depolarizing prepulses. A second form of inhibition was neither associated with slowing of the activation kinetics nor relieved by depolarizing prepulses and was thus voltage independent. In all neurons examined, 5-HT (1 μM) reversibly reduced 34 ± 1.6 % (n = 102) of the HVA Ca2+ currents. In about 40 % of neurons, the inhibition was totally voltage independent. In another 5 %, the inhibition was totally voltage dependent. In the remaining neurons, inhibition was only partially (by around 40 %) relieved by a large depolarizing prepulse, suggesting that in these, the inhibition consisted of both voltage-dependent and -independent components. By using selective channel blockers, we found that 5-HT acted on both N- and P/Q-type channels. However, whereas the inhibition of P/Q-type currents was only voltage independent, the inhibition of N-type currents had both voltage-dependent and -independent components. The effects of 5-HT on HVA Ca2+ currents were mediated by 5-HT1A and 5-HT1D receptors. The 5-HT1A receptors not only preferentially caused voltage-independent inhibition, but did so by acting mainly on the ω-agatoxin-IVA-sensitive Ca2+ channels. In contrast, the 5-HT1D receptor produced both voltage-dependent and -independent inhibition and was preferentially coupled to ω-conotoxin-GVIA sensitive channels. This complexity of modulation may allow fine tuning of transmitter release and calcium signalling in the spinal circuitry of Xenopus larvae. PMID:9625870

  17. Epileptic negative drop attacks in atypical benign partial epilepsy: a neurophysiological study.

    PubMed

    Hirano, Yoshiko; Oguni, Hirokazu; Osawa, Makiko

    2009-03-01

    We conducted a computer-assisted polygraphic analysis of drop attacks in a child with atypical benign partial epilepsy (ABPE) to investigate neurophysiological characteristics. The patient was a six-year two-month-old girl, who had started to have focal motor seizures, later combined with daily epileptic negative myoclonus (ENM) and drop attacks, causing multiple injuries. We studied episodes of ENM and drop attacks using video-polygraphic and computer-assisted back-averaging analysis. A total of 12 ENM episodes, seven involving the left arm (ENMlt) and five involving both arms (ENMbil), and five drop attacks were captured for analysis. All episodes were time-locked to spike-and-wave complexes (SWC) arising from both centro-temporo-parietal (CTP) areas. The latency between the onset of SWC and ENMlt, ENMbil, and drop attacks reached 68 ms, 42 ms, and 8 ms, respectively. The height of the spike as well as the slow-wave component of SWC for drop attacks were significantly larger than that for both ENMlt and ENMbil (p < 0.05). Drop attacks were considered to be epileptic negative myoclonus involving not only upper proximal but also axial muscles, causing the body to fall. Thus, drop attacks in ABPE are considered to be epileptic negative drop attacks arising from bilateral CTP foci and differ from drop attacks of a generalized origin seen in Lennox-Gastaut syndrome and myoclonic-astatic epilepsy.

  18. Rotating Molten Metallic Drops and Related Phenomena: A New Approach to the Surface Tension Measurement

    NASA Technical Reports Server (NTRS)

    Rhim, Won-Kyu; Ishikawa, Takehiko

    2000-01-01

    Molten aluminum and tin drops were levitated in a high vacuum by controlled electric fields, and they were systematically rotated by applying by a rotating magnetic field. When the evolution of the drop shape was measured as a function of rotation frequency, it agreed quantitatively well with the Brown and Scriven's theoretical prediction. The normalized rotation frequencies at the bifurcation point agreed with the predicted value 0.559, within 2%. An anomalous phenomenon which totally deviated from the prediction was observed in rotating molten tin drops when they were kept in a high rotation rate for several hours. No anomaly was observed in aluminum drops when they underwent similar condition. It was speculated that under the strong centrifugal force in the drop the tin isotopes must be separating. Since Al-27 is essentially the only naturally abundant isotope in the aluminum drops, the same anomaly is not expected. Based on the shape deformation of a rotating drop, an alternate approach to the surface tension measurement was verified. This new surface tension measurement technique was applied to a glassforming alloy, Zr(41.2)Ti(13.8)Cu(12.5)Ni(10.0)Be(22.5) in its highly viscous states. Also demonstrated in the paper was a use of a molten aluminum drop to verify the Busse's prediction of the influence of the drop rotation on the drop oscillation frequency.

  19. The Chemical and Educational Appeal of the Orange Juice Clock

    NASA Astrophysics Data System (ADS)

    Kelter, Paul B.; Carr, James D.; Johnson, Tanya; Mauricio Castro-Acuña, Carlos

    1996-12-01

    The Orange Juice Clock, in which a galvanic cell is made from the combination of a magnesium strip, a copper strip, and juice in a beaker, has been a popular classroom, conference, and workshop demonstration for nearly 10 years. It is widely enjoyed because it shows visually how chemistry - or more precisely, electrochemistry - is responsible for the very common phenomenon of a clock ticking. The chemistry of the process can also be understood on a variety of levels, from middle school (simple electron flow in a circuit, Ohm's law) and high school (reduction/oxidation and standard cell potentials) to first-year college (cell potential at nonideal conditions) and graduate school courses (overpotential and charge transfer across interfaces.) The discussion that follows considers the recent history, chemistry, and educational uses of the demonstration. The History The demonstration was devised by one of us (PK) in 1986, after reading an activity in Hubert Alyea's 1947 compendium of chemical demonstrations from this Journal (1). In that activity, Alyea hooked a magnesium strip to the negative battery terminal of an electric bell and hooked a copper strip to the positive terminal. He placed the loose ends of the strips into a 1M 2SO4 solution and the bell rang. After trying the demonstration, it seemed to make sense to modify the electrolyte to orange juice because it is safe, readily available, and would be a mixture in which the magnesium would oxidize more slowly than in sulfuric acid. Further, a clock was substituted for the bell because a clock is easier on the ears than a bell. A video of the orange-juice clock setup is given as Figure 1. Figure 1.The orange juice clock set up. Video of orange juice clock was filmed and editted by Jerry Jacobson at the University of Wisconsin - Madison. The apparatus was presented in 1987 as part of a teacher workshop led by Irwin Talesnick, then of Queen's University in Canada. Talesnick, whose distinguished career has been characterized by seeing educational possibilities in so many things, created a modified version of the clock, with the atomic numbers of the elements representing the hours in the day (see Fig. 2) in his internationally popular workshops. Due largely to Talesnick's efforts, the orange juice clock is a standard demonstration in many chemistry programs and presentations. Figure 2.Irwin Talesnick represents the hours of the day by the corresponding elements in his clock. The Procedure This can be done as a demonstration or as an activity, although at about 10 per clock, expense does become an issue. There are no unusual safety precautions with this demonstration. We know of no accidents that have occurred with the orange juice clock. The demonstration requires: a single AA-cell battery-operated wall clock with a sweep-second hand a medium-sized beaker (600 mL is fine) enough orange juice or other electrolyte mixture or solution to fill the beaker about 2/3 full (tap water often works fine!) a 20-30-cm magnesium strip, coiled at one end or wrapped around a popsicle stick a 20-30-cm copper strip, coiled at one end alligator clips to connect the strips to the battery terminals on the clock a stand against which to lean the setup The demonstration is put together as shown in Figure 3. Connect the magnesium to the "-" contact of the clock and the copper to the "+" contact. Immerse the other ends of the strips into the solution. The clock will start to tick within a few seconds. If it does not work within a short period of time, check that the strips are well connected to the battery terminals, are hooked to the proper poles, and are not touching each other. The clock should keep reasonably close time (in orange juice) for a couple of days, or until the magnesium is nearly completely oxidized. Figure 3.A schematic of the orange juice clock seup. Video of orange juice clock. In video, the copper electrode is on the left and the magnesium electrode is on the right. Video was filmed and editted by Jerry Jacobson at the University of Wisconsin - Madison. The Chemistry Basics When we ask students or precollege teacher groups about the reduction and oxidation reactions that are occurring, they invariably answer that the magnesium metal is being oxidized and the copper metal is being reduced. This response is important because we use it to impress upon students and workshop participants the importance of looking carefully at the system before giving what might seem like an obvious answer. The copper cannot be reduced because there is no copper ion in solution, and transition metals cannot be reduced to anions. Given what is actually in solution, participants can conclude that hydrogen ion can be reduced to molecular hydrogen (in orange juice) or that hydrogen in the water molecule is being reduced to molecular hydrogen (in hard tap water). In distilled water, the clock does not run because the internal resistance of the solution is too high, thus forcing the current to be very small. The reactions of interest are given as eqs 1-3: oxidation: Mg -> Mg2+ + 2e- Eo = 2.37 vs. SHE (1) reduction 2H+ + 2e- -> H2 Eo = 0.00 vs. SHE (2) (acid solution) reduction (water) 2H2O + 2e- -> H2 + 2OH- Eo = -0.8277 vs. SHE (3) where Eo = the voltage under standard conditions and SHE = standard hydrogen electrode. At standard conditions, under zero load (all activities equal to one and 298 K) the cell voltage should theoretically be 2.37 V in acid (pH = 1) and about 1.54 V in neutral solution, either of which is enough to allow the clock to run. It is important to remember the IUPAC convention for electrochemical cells: that voltage of the cell equals voltage of the cathodic half-cell minus voltage of the anodic half-cell. In this case, Eo = 0.00 V - (-2.37 V) = 2.37 V The standard free energy calculation is straightforward in each case (eq 4), DeltaGo = -nFEo in which n = number of moles of electrons transferred, as dictated by the stoichiometry of the reaction (in all reactions above, n = 2); F = Faraday's constant, 96,498 C per mole of electrons (it is useful to show students that this number is equal to the product of Avogadro's number and electron charge); and Eo = cell voltage under standard conditions (Eo = 2.37 V = 2.37 J/C in acid solution of pH = 1). In acid solution, DeltaG = -457,000 J = -4.57 kJ. The reaction is spontaneous (and there is enough current flow). The clock ticks. This represents an overview of the fundamental chemistry, suitable for a workshop, high school, or non-science first-year college audience. The discussion below considers some more advanced aspects of the demonstration, which make this an excellent demonstration for the first-year science majors' course as well as upper- and graduate-level analytical and electrochemistry courses. For Those Who Want More More advanced students can readily explore the parameters of the clock system beyond merely studying cell voltage at standard conditions. In this system, for example, two sources contribute to the oxidation of the magnesium electrode. One is the reaction with acid as part of the process that runs the clock. Also present is the reaction in acid solution that occurs irrespective of the electron flow used to run the clock, a process of corrosion that dissolves the metal without useful energy being obtained. It is possible to distinguish between the two and to determine, via Faraday's constant, the average current available to the clock in this system. Faraday's Constant and the Average Current Data for a typical determination are given in Table 1. The data were taken using a 0.3317-g magnesium strip that had been cleaned with steel wool. The magnesium and copper strips (the copper was cleaned by dipping in 1 M nitric acid for a few seconds) were placed in 400 mL of a commercial orange juice so that about 15 cm of each strip was above and 15 cm below the liquid line. About 5 cm of the magnesium strip was coiled. The clock was hooked up in the usual fashion. At 1-hour intervals, the mass of the magnesium wire was determined on an analytical balance. A digital multimeter was used to measure the voltage every hour and the current every other hour. The pH of the juice, initially 3.85 at 20 °C, was 3.93 at the end of the experiment, as measured with a portable pH meter. This is a typical result. A comparison system (called "no clock" in Table 1) was set up merely by putting a 0.3317-g strip of magnesium in 400 mL of orange juice. With this system we can exemplify a "corrosion process" where the anode and the cathode are in the same place. There is consumption of magnesium and evolution of molecular hydrogen but no useful current can be obtained. The mass of this magnesium strip was measured at 1-hour intervals. Faraday's constant, which relates coulombs to moles of electrons, can be used to calculate the approximate current available to the clock in this system. The current will not be constant because the H+ concentration (related to pH) is changing and also because the surface area and composition of the magnesium electrode change with time. The change is not necessarily regular, because although the surface is being oxidized, it is not smooth. The actual available surface area will therefore be considerably greater than the geometric surface. The mass of magnesium oxidized in the clock reaction over the 4-hour period is approximately equal to the change in grams of magnesium while running the clock minus the mass of magnesium oxidized in orange juice without the clock. Using the data from Table 1, grams Mg oxidized to run clock = approx. (0.3317 - 0.3089) - (0.3317 - 0.3136) = 0.0047 g Mg The average current can then be calculated via Faraday's constant: This is a rather simplistic way to get the current, but it shows well the use of Faraday's constant. The Value of Computer Interfacing - Exploring the Physics of Current/Voltage Measurements A more instructive measure of voltage vs. time, which opens up the activity to more interesting possibilities, was obtained by interfacing the clock to a Macintosh 8100/80 microcomputer via Vernier Corporation serial box interface hardware and software (see ref 2). This affordable (100-$250 per computer) interfacing package is being used in our first-year chemistry laboratories. The interfacing setup permitted data to be acquired at the much more meaningful rate of up to 50 points per second. It also permitted us to observe voltage variations with time while the strips in orange juice were hooked up to the clock. When data are taken 50 times per second rather than once every hour, the data take on new meaning. Figure 4 shows that there is a substantial drop in voltage each time the clock ticks. Figure 4.The observed voltage drop in the circuit corresponds to the ticking of the clock. The drop is due to the internal resistance of the orange juice solution. Video of orange juice clock connected to chart recorder demostrating voltage drop in the circuit as clock ticks. Video was filmed and editted by Jerry Jacobson at the University of Wisconsin - Madison. This observation can be explained and can be predicted as part of a student activity, if we understand the nature of an open vs. a short circuit. A battery can, in concept, perform between two extreme points: an open circuit, in which the voltage (V) is at a maximum but there is no current (I), and a short circuit, in which the current is at a maximum but there is no voltage. A battery is best used at an intermediate point where the power, I xV, is a maximum. In summary (eqs 5-7): (5) Open Circuit: V = maximum and I = 0 (6) Short Circuit: I = maximum and V = 0 (7) Battery Use: I x V = power = maximum A 1.5-V battery has an open circuit potential of 1.5 volts. When the battery is working, however, the real voltage will be less than 1.5 V. This is due to the internal resistance of the battery. So the real voltage of the battery (Vreal) equals the open circuit voltage (Vopen) minus the voltage drop due to internal resistance in the battery. This drop is equal to the current passing through the circuit (I) multiplied by the internal resistance of the battery (Rint), as shown in eq 8: Vreal = Vopen - I x Rint (8) If the current passing is 0.002 A and the internal resistance of a 1.5-V battery is 50 Ohms, the real voltage is 1.4 V: Vreal = 1.5 V - (0.0020 A x 50 Ohms) = 1.4 V In this activity, in which we make a battery with a magnesium and a copper strip in orange juice, the juice itself provides the internal resistance in the battery. The key then to determining what the voltage drop should be is to find the internal resistance of the orange juice and then to find the current passing through the clock circuit. Students can determine the internal resistance of the orange juice by performing the following measurements. Note that the internal resistance of the orange juice is highly dependent upon how far apart the strips are in solution. The strips should be firmly taped, top and bottom, to the beaker. The data below were typical for 0.35-g Mg and 6.0-g Cu strips that were 4 cm apart in a 600-mL beaker with 400 mL of orange juice. The solution was not stirred. The area of the strips in solution was about 7.5 cm2 for the magnesium and about 15 cm2 for the copper. 1. Measure, using a high-impedance voltmeter, the voltage of the circuit using the voltmeter itself, rather than the clock, to complete the circuit. This will give a good approximation of the open circuit potential (the current is negligible, on the order of microamps if the voltmeter has MOhm resistance). In our setup Vopen = 1.772 V. 2. Attach a 1000-Ohm resistor across the circuit. Measure the voltage in parallel to the resistor. This voltage (1.037 V in our setup) will be equal to the current in the circuit x the resistance of 1000 Ohm. We can now solve for the current in this circuit: I = V/R = 1.037 V/1000 Ohm = 0.001037 A = 1.037 mA 3. The resistance of the orange juice is then calculated via the difference between the open circuit voltage (1.772 V) and the voltage with a known resistance (1.037 V). The difference, 1.772 - 1.037 = 0.735 V, equals the product of the circuit current and the resistance of the orange juice (ROJ), or ROJ = 0.735 V/0.001037 A = 708 Ohm 4. Finally, measure the current that the clock itself requires by hooking up in series an ammeter to the battery and the clock. The reading is not easy to take with an ammeter, which does not sample very often, and integrates across time. The computer interface works better for this. In our clock, a current of 0.49 mA was used. 5. The payoff comes at this point. The predicted voltage drop (I x Rint) can be calculated, voltage drop = I x Rint = 0.00049 A x 708 Ohm = 0.35 V Our observed voltage drops for this system were typically around 0.30 V. As a confirmation of the relationship of internal resistance to voltage drop, we placed the strips 1 mm apart in an orange by digging 2 holes in the orange and placing into the holes the coiled parts of the strips. We expected the voltage drop to be much higher than with the juice, due to the much higher internal resistance of the orange. Even when the strips were nearly touching, the drop was about 1 V. The Water Clock We discussed above the difference in the redox system when water is used rather than orange juice. Distilled water, which has a high internal resistance, will not permit the clock to run. However, hard tap water or distilled water with, for example, 1 g of table salt in 300 mL of water will work fine. As expected, because of the lower hydrogen ion concentration, the initial cell voltage is lower, typically around 1.45 V. The clock also ticks more slowly and more softly in water than in orange juice. In water, a black precipitate forms on the magnesium electrode and becomes more extensive with time. When the strip is removed from distilled water, and allowed to dry the precipitate turns white. Further student exploration on the precipitate might include designing experiments to find out if the precipitate is a carbonate or an oxide (from the hydroxide.) Non-Nernstian Considerations The systems above were always run without stirring because when setting up demonstrations, portability, simplicity, and expense are important, and the main concepts are as clear with a stir bar as without. We do note, however, that when the solution is constantly stirred, the rate of magnesium oxidation both with the clock setup and simply in solution is considerably faster than when the process is diffusion-limited. In fact, whereas the Mg strip will often last for several days in very dilute acid and overnight in orange juice when the solutions are not stirred, it will break off within 4 h when the solutions are stirred. Another important issue relates to our use of the Nernst equation to account for the potential developed in the system. This equation is very useful to assess chemistry at equilibrium conditions, but the orange juice clock is using an electric current and so is not at equilibrium. In our orange juice system, the Nernst equation (eq 9) is, in which E° = E°Mg - E°H2 - h and h = overpotential = difference in H2/H+ couple at a copper electrode minus that at platinum black. The hydrogen overpotential on a copper surface is typically 0.23 V. Another treatment of overpotential is given below. In our experiments, magnesium concentration and hydrogen activity were not measured or controlled; the pH was 3.85-3.93, as described above. The maximum theoretical potential of the electrode system is greater than that which is available to the clock when there is current flow. As described above, the potential drop is calculated as current ¥ internal resistance, equaling the "iR drop." This is why potentials are measured with a voltmeter, with a very high internal resistance, which draws very little current from the system. The measure of how far a system is from equilibrium is called the overpotential (h) h = actual potential minus potential at equilibrium This, along with the anodic and the cathodic components, the energy involved, and the temperature of the system are all dealt with using the Butler-Volmer equation, given as eq 10: I = io(e+Fh/2RT - e-Fh/2RT) (10) in which io is a specific constant for every system "electrode-electrolyte" and is called the "equilibrium exchange current." For this case, we have assumed the symmetry factor to be equal to 1/2. A detailed discussion of this factor is beyond the purpose of this paper, but can be found in ref 3. Questions To Raise with Students/Teacher Workshop Participants This demonstration can be a starting point for many concepts. It is especially powerful in showing how chemistry can be used beyond the chemistry laboratory. The primary question is "how is this system different from that in which redox occurs at one surface (such as a zinc strip placed in a solution of copper sulfate)?" The key with this electrochemical cell is that we are separating the anode from the cathode to take advantage of the electron flow (current) through an external wire and this current will give power to the clock or any other device. This is the essence of a battery. Other questions we often ask are: Is enough current produced to run a small electric motor? Light a light? Would the system work if we put Cu2+ ions into the solution? What would happen if we titrate the acid solution with a strong base while the clock is running? What happens to the voltage if we put Mg2+ into the system? Are the complex ions of Mg2+ with citric acid important to the potential value? What is the relationship between the clock ticking and different juices? Why is this relationship so? What are the reactions in the most popular commercial batteries? What is the chemical basis of rechargeable batteries? Related Activities We do this demonstration while studying electrochemistry during the second semester of the general chemistry sequence. In precollege teacher workshops, it is an important focus of an Operation Chemistry unit dealing with energy needs for living on board the space shuttle (4). A number of fairly safe activities work well as lead-in or follow-up material, as described in Table 2. Copies of these activities are available by writing to PK. Acknowledgments We wish to thank Walt Hancock and Jonathan Skean, along with our wonderful undergraduates Mickey Richards, Cory Emal, Julie Grundman, Jeff Atkins, and Darren Jack, for being there. Literature Cited 1. Alyea, H. N. Tested Demonstrations in General Chemistry, 1955-1956; American Chemical Society: Washington, DC, 1956. 2. Vernier Software, 8565 SW Beaverton Hillsdale Highway, Portland, OR 97225; phone (503) 297-5317. 3. Bockris, J.; Reddy, A. K. N. Modern Electrochemistry; Plenum: New York, 1970; Vol 2. 4. Kelter, P.; Hughes, K.; Murphy, A.; Roskos, P. J. Sci. Teacher Educ. 1995, 6, 57-59. 5. Tested Demonstrations in Chemistry; Gilbert, G., Ed.; American Chemical Society: Washington, DC, 1994; Vol. 1, #E-13. 6. Katz, D. A.; Willis, C. J. Chem. Educ. 1994, 71, 330-331. 7. Holmquist, D. D.; Volz, D. L. Chemistry with Computers;Vernier Software, Portland OR, 1994.

  20. Does voltage predict return to work and neuropsychiatric sequelae following electrical burn injury?

    PubMed

    Chudasama, Shruti; Goverman, Jeremy; Donaldson, Jeffrey H; van Aalst, John; Cairns, Bruce A; Hultman, Charles Scott

    2010-05-01

    Voltage has historically guided the acute management and long-term prognosis of physical morbidity in electrical injury patients; however, few large studies exist that include neuropsychiatric morbidity in final outcome analysis. This review compares high (>1000 V) to low (<1000 V) voltage injuries, focusing on return to work and neuropsychiatric sequelae following electrical burn injury. Patients with electrical injuries admitted to the University of North Carolina Jaycee Burn Center between 2000 and 2005 were prospectively entered into a trauma database, then retrospectively reviewed. Patients were divided into 4 cohorts: high voltage (>1000 V), low voltage (<1000 V), flash arc, and lightning. Demographics, hospital course, and follow-up were recorded to determine physical and neuropsychiatric morbidity. Differences among cohorts were tested for statistical significance. Over 5 years, 2548 patients were admitted to the burn center, including 115 patients with electrical injuries. There were 110 males and 5 females, with a mean age of 35 years (range, 0.75-65 years). The cause of the electrical injury was high voltage in 60 cases, low voltage in 25 cases, flash arc in 29 cases and lightning in 1 case. The mean total body surface area burn was 8% (range, 0%-52%). The etiology was work-related electrical injury in 85 patients. Mean follow-up period was 352 days with 13 (11%) patients lost to follow-up. Patients with high voltage injuries had significantly larger total body surface area burn, longer ICU stays, longer hospitalizations, and significantly higher rates of fasciotomy, amputation, nerve decompression and outpatient reconstruction, with 4 cases of renal failure and 2 deaths. In spite of these differences, high and low voltage groups experienced similar rates of neuropsychiatric sequelae, limited return to work and delays in return to work. Final impairment ratings for the high and low voltage groups were 17.5% and 5.3%, respectively. Electrical injuries often incur severe morbidity despite relatively small burn size and/or low voltage. When comparing high and low voltage injuries, similarities in endpoints such as neuropsychiatric sequelae, the need for late reconstruction, and failure to return to work challenge previous notions that voltage predicts outcome.

  1. Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.

    PubMed

    Williams, Monique; Talbot, Prue

    2011-12-01

    This study investigated the performance of electronic cigarettes (e-cigarettes), compared different models within a brand, compared identical copies of the same model within a brand, and examined performance using different protocols. Airflow rate required to generate aerosol, pressure drop across e-cigarettes, and aerosol density were examined using three different protocols. First 10 puff protocol: The airflow rate required to produce aerosol and aerosol density varied among brands, while pressure drop varied among brands and between the same model within a brand. Total air hole area correlated with pressure drop for some brands. Smoke-out protocol: E-cigarettes within a brand generally performed similarly when puffed to exhaustion; however, there was considerable variation between brands in pressure drop, airflow rate required to produce aerosol, and the total number of puffs produced. With this protocol, aerosol density varied significantly between puffs and gradually declined. CONSECUTIVE TRIAL PROTOCOL: Two copies of one model were subjected to 11 puffs in three consecutive trials with breaks between trials. One copy performed similarly in each trial, while the second copy of the same model produced little aerosol during the third trial. The different performance properties of the two units were attributed to the atomizers. There was significant variability between and within brands in the airflow rate required to produce aerosol, pressure drop, length of time cartridges lasted, and production of aerosol. Variation in performance properties within brands suggests a need for better quality control during e-cigarette manufacture.

  2. The variability of the rainfall rate as a function of area

    NASA Astrophysics Data System (ADS)

    Jameson, A. R.; Larsen, M. L.

    2016-01-01

    Distributions of drop sizes can be expressed as DSD = Nt × PSD, where Nt is the total number of drops in a sample and PSD is the frequency distribution of drop diameters (D). Their discovery permitted remote sensing techniques for rainfall estimation using radars and satellites measuring over large domains of several kilometers. Because these techniques depend heavily on higher moments of the PSD, there has been a bias toward attributing the variability of the intrinsic rainfall rates R over areas (σR) to the variability of the PSDs. While this variability does increase up to a point with increasing domain dimension L, the variability of the rainfall rate R also depends upon the variability in the total number of drops Nt. We show that while the importance of PSDs looms large for small domains used in past studies, it is the variability of Nt that dominates the variability of R as L increases to 1 km and beyond. The PSDs contribute to the variability of R through the relative dispersion of χ = D3Vt, where Vt is the terminal fall speed of drops of diameter D. However, the variability of χ is inherently limited because drop sizes and fall speeds are physically limited. In contrast, it is shown that the variance of Nt continuously increases as the domain expands for physical reasons explained below. Over domains larger than around 1 km, it is shown that Nt dominates the variance of the rainfall rate with increasing L regardless of the PSD.

  3. Distributed Optimal Dispatch of Distributed Energy Resources Over Lossy Communication Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Junfeng; Yang, Tao; Wu, Di

    In this paper, we consider the economic dispatch problem (EDP), where a cost function that is assumed to be strictly convex is assigned to each of distributed energy resources (DERs), over packet dropping networks. The goal of a standard EDP is to minimize the total generation cost while meeting total demand and satisfying individual generator output limit. We propose a distributed algorithm for solving the EDP over networks. The proposed algorithm is resilient against packet drops over communication links. Under the assumption that the underlying communication network is strongly connected with a positive probability and the packet drops are independentmore » and identically distributed (i.i.d.), we show that the proposed algorithm is able to solve the EDP. Numerical simulation results are used to validate and illustrate the main results of the paper.« less

  4. Electrochemically controlled charging circuit for storage batteries

    DOEpatents

    Onstott, E.I.

    1980-06-24

    An electrochemically controlled charging circuit for charging storage batteries is disclosed. The embodiments disclosed utilize dc amplification of battery control current to minimize total energy expended for charging storage batteries to a preset voltage level. The circuits allow for selection of Zener diodes having a wide range of reference voltage levels. Also, the preset voltage level to which the storage batteries are charged can be varied over a wide range.

  5. Microbial fuel cell-based biosensor for toxic carbon monoxide monitoring.

    PubMed

    Zhou, Shaofeng; Huang, Shaobin; Li, Yi; Zhao, Nannan; Li, Han; Angelidaki, Irini; Zhang, Yifeng

    2018-08-15

    This study presents an innovative microbial fuel cell-based biosensor for carbon monoxide (CO) monitoring. The hypothesis for the function of the biosensor is that CO inhibits bacterial activity in the anode and thereby reduces electricity production. A mature electrochemically active biofilm on the anode was exposed to CO gas at varied concentrations. A proportional linear relationship (R 2 = 0.987) between CO concentration and voltage drop (0.8 to 24 mV) in the range of 10% and 70% of CO concentration was observed. Notably, no further decrease of voltage output was observed by with further increasing CO concentration over 70%. Besides, the response time of the biosensor was 1 h. The compact design and simple operation of the biosensor makes it easy to be integrated in existing CO-based industrial facilities either as a forewarning sensor for CO toxicity or even as an individual on-line monitoring device. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. A Wireless Self-Powered Urinary Incontinence Sensor System

    NASA Astrophysics Data System (ADS)

    Tanaka, Ami; Utsunomiya, Fumiyasu; Douseki, Takakuni

    A self-powered urinary incontinence sensor system consisting of a urine-activated coin battery and a wireless transmitter has been developed as an application for wireless biosensor networks. The urine-activated battery makes possible both the sensing of urine leakage and self-powered operation. An intermittent power-supply circuit that uses an electric double-layer capacitor (EDLC) with a small internal resistance suppresses the supply voltage drop due to the large internal resistance of the battery. This circuit and a 1-V surface acoustic wave (SAW) oscillator reduce the power dissipation of a wireless transmitter. The SAW oscillator quickly responds to the on-off control of the power supply, which is suitable for intermittent operation. To verify the effectiveness of the circuit scheme, the authors fabricated a prototype sensor system. When the volume of urine is 0.2 ml, the battery outputs a voltage of over 1.3 V; and the sensor system can transmit signals over a distance of 5 m.

  7. Experimental Study of Heating of a Liquid Cathode and Transfer of Its Components into the Gas Phase under the Action of a DC Discharge

    NASA Astrophysics Data System (ADS)

    Sirotkin, N. A.; Titov, V. A.

    2018-04-01

    An atmospheric-pressure dc discharge in air ( i = 10-50 mA) with metal and liquid electrolyte electrodes was studied experimentally. An aqueous solution of sodium chloride (0.5 mol/L) was used as the cathode or anode. The electric field strength in the plasma and the cathode (anode) voltage drops were obtained from the measured dependences of the discharge voltage on the electrode gap length. The gas temperature was deduced from the spectral distribution of nitrogen emission in the band N2( C 3Π u → B 3Π g , 0-2). The time dependences of the temperatures of the liquid electrolyte electrodes during the discharge and in its afterglow, as well as the evaporation rate of the solution, were determined experimentally. The contributions of ion bombardment and heat flux from the plasma to the heating of the liquid electrode and transfer of solvent (water) into the gas phase are discussed using the experimental data obtained.

  8. Droplet Velocity Measurement Based on Dielectric Layer Thickness Variation Using Digital Microfluidic Devices.

    PubMed

    Zulkepli, Siti Noor Idora Syafinaz; Hamid, Nor Hisham; Shukla, Vineeta

    2018-05-08

    In recent years, the number of interdisciplinary research works related to the development of miniaturized systems with integrated chemical and biological analyses is increasing. Digital microfluidic biochips (DMFBs) are one kind of miniaturized systems designed for conducting inexpensive, fast, convenient and reliable biochemical assay procedures focusing on basic scientific research and medical diagnostics. The role of a dielectric layer in the digital microfluidic biochips is prominent as it helps in actuating microliter droplets based on the electrowetting-on-dielectric (EWOD) technique. The advantages of using three different material layers of dielectric such as parafilm, polytetrafluoroethylene (PTFE) and ethylene tetrafluoroethylene (ETFE) were reported in the current work. A simple fabrication process of a digital microfluidic device was performed and good results were obtained. The threshold of the actuation voltage was determined for all dielectric materials of varying thicknesses. Additionally, the OpenDrop device was tested by utilizing a single-plate system to transport microliter droplets for a bioassay operation. With the newly proposed fabrication methods, these dielectric materials showed changes in contact angle and droplet velocity when the actuation voltage was applied. The threshold actuation voltage for the dielectric layers of 10⁻13 μm was 190 V for the open plate DMFBs.

  9. Dye based photodiodes for solar energy applications

    NASA Astrophysics Data System (ADS)

    Mensah-Darkwa, K.; Ocaya, R.; Dere, A.; Al-Sehemi, Abdullah G.; Al-Ghamdi, Ahmed A.; Soylu, M.; Gupta, R. K.; Yakuphanoglu, F.

    2017-10-01

    Coumarin (CO) doped methylene blue (MB) organic photo-devices were fabricated. The CO-doped MB (0.00, 0.01, 0.03, 0.05, 0.1 wt% CO) were coated onto the surface of a p-type Si substrate by drop casting method. Some electrical parameters of the devices have been examined by current-voltage ( I- V), capacitance-voltage ( C- V), and conductance-voltage ( G- V) measurements. The fabricated devices had excellent rectifying properties. The diode exhibits a non-ideal diode behavior due to the series resistance and interface layer. The ideality factor, the barrier height, and the series resistance values of the diode as a function of doping and light illumination have been estimated using modified Cheung-Cheung and Norde's method. The highest I photo/ I dark photosensitivity of 5606 was observed for the diode having 0.01 CO doping at 100 mW/cm2 under -3 V. Furthermore, change of capacitance and conductance measurements with frequency is related to the existence of interface states. A maximum power conversion efficiency of 2.4% is estimated for the fabricated devices. The results reveal that coumarin-doped methylene blue/ p-Si heterojunction can be used as a photodiode in optoelectronic applications. It is also usable in low-power photovoltaic applications.

  10. Advanced Bode Plot Techniques for Ultrasonic Transducers

    NASA Astrophysics Data System (ADS)

    DeAngelis, D. A.; Schulze, G. W.

    The Bode plot, displayed as either impedance or admittance versus frequency, is the most basic test used by ultrasonic transducer designers. With simplicity and ease-of-use, Bode plots are ideal for baseline comparisons such as spacing of parasitic modes or impedance, but quite often the subtleties that manifest as poor process control are hard to interpret or are nonexistence. In-process testing of transducers is time consuming for quantifying statistical aberrations, and assessments made indirectly via the workpiece are difficult. This research investigates the use of advanced Bode plot techniques to compare ultrasonic transducers with known "good" and known "bad" process performance, with the goal of a-priori process assessment. These advanced techniques expand from the basic constant voltage versus frequency sweep to include constant current and constant velocity interrogated locally on transducer or tool; they also include up and down directional frequency sweeps to quantify hysteresis effects like jumping and dropping phenomena. The investigation focuses solely on the common PZT8 piezoelectric material used with welding transducers for semiconductor wire bonding. Several metrics are investigated such as impedance, displacement/current gain, velocity/current gain, displacement/voltage gain and velocity/voltage gain. The experimental and theoretical research methods include Bode plots, admittance loops, laser vibrometry and coupled-field finite element analysis.

  11. Investigation of surface charge density on solid-liquid interfaces by modulating the electrical double layer.

    PubMed

    Moon, Jong Kyun; Song, Myung Won; Pak, Hyuk Kyu

    2015-05-20

    A solid surface in contact with water or aqueous solution usually carries specific electric charges. These surface charges attract counter ions from the liquid side. Since the geometry of opposite charge distribution parallel to the solid-liquid interface is similar to that of a capacitor, it is called an electrical double layer capacitor (EDLC). Therefore, there is an electrical potential difference across an EDLC in equilibrium. When a liquid bridge is formed between two conducting plates, the system behaves as two serially connected EDLCs. In this work, we propose a new method for investigating the surface charge density on solid-liquid interfaces. By mechanically modulating the electrical double layers and simultaneously applying a dc bias voltage across the plates, an ac electric current can be generated. By measuring the voltage drop across a load resistor as a function of bias voltage, we can study the surface charge density on solid-liquid interfaces. Our experimental results agree very well with the simple equivalent electrical circuit model proposed here. Furthermore, using this method, one can determine the polarity of the adsorbed state on the solid surface depending on the material used. We expect this method to aid in the study of electrical phenomena on solid-liquid interfaces.

  12. Riata silicone defibrillation lead with normal electrical measures at routine ambulatory check: The role of high-voltage shock testing

    PubMed Central

    De Maria, Elia; Borghi, Ambra; Bonetti, Lorenzo; Fontana, Pier Luigi; Cappelli, Stefano

    2016-01-01

    AIM To describe our experience with shock testing for the evaluation of patients with Riata™ leads. METHODS Among 51 patients with normal baseline electrical parameters, 20 died during follow-up. Of the remaining 31 patients, 15 underwent the test: In 10 cases a defibrillation testing with ventricular fibrillation (VF) induction and in 5 cases a R-wave-synchronized shock (> 20 J, without inducing VF). The test was performed under sedation with Midazolam. RESULTS Twelve patients (80%) had a normal behavior during shock testing: In 8 cases induced VF was correctly detected and treated; in 4 cases of R-wave-synchronized shock electrical parameters remained stable and normal. Three patients (20%) failed the test. One patient with externalized conductors showed a sudden drop of high-voltage impedance (< 10 Ohm) after a 25 J R-wave-synchronized shock. Two other patients with externalized conductors, undergoing defibrillation testing, showed a short-circuit during shock delivery and the implantable cardioverter defibrillator was unable to interrupt VF. CONCLUSION In Riata™ leads the delivery of a low current during routine measurement of high-voltage impedance may not reveal a small short circuit, that can only be evident by attempting to deliver a true shock, either for spontaneous arrhythmias or in the context of a shock testing. PMID:27957252

  13. Avoiding neuromuscular stimulation in liver irreversible electroporation using radiofrequency electric fields

    NASA Astrophysics Data System (ADS)

    Castellví, Quim; Mercadal, Borja; Moll, Xavier; Fondevila, Dolors; Andaluz, Anna; Ivorra, Antoni

    2018-02-01

    Electroporation-based treatments typically consist of the application of high-voltage dc pulses. As an undesired side effect, these dc pulses cause electrical stimulation of excitable tissues such as motor nerves. The present in vivo study explores the use of bursts of sinusoidal voltage in a frequency range from 50 kHz to 2 MHz, to induce irreversible electroporation (IRE) whilst avoiding neuromuscular stimulation. A series of 100 dc pulses or sinusoidal bursts, both with an individual duration of 100 µs, were delivered to rabbit liver through thin needles in a monopolar electrode configuration, and thoracic movements were recorded with an accelerometer. Tissue samples were harvested three hours after treatment and later post-processed to determine the dimensions of the IRE lesions. Thermal damage due to Joule heating was ruled out via computer simulations. Sinusoidal bursts with a frequency equal to or above 100 kHz did not cause thoracic movements and induced lesions equivalent to those obtained with conventional dc pulses when the applied voltage amplitude was sufficiently high. IRE efficacy dropped with increasing frequency. For 100 kHz bursts, it was estimated that the electric field threshold for IRE is about 1.4 kV cm-1 whereas that of dc pulses is about 0.5 kV cm-1.

  14. Ion properties in a Hall current thruster operating at high voltage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garrigues, L., E-mail: laurent.garrigues@laplace.univ-tlse.fr

    2016-04-28

    Operation of a 5 kW-class Hall current Thruster for various voltages from 400 V to 800 V and a xenon mass flow rate of 6 mg s{sup −1} have been studied with a quasi-neutral hybrid model. In this model, anomalous electron transport is fitted from ion mean velocity measurements, and energy losses due to electron–wall interactions are used as a tuned parameter to match expected electron temperature strength for same class of thruster. Doubly charged ions production has been taken into account and detailed collisions between heavy species included. As the electron temperature increases, the main channel of Xe{sup 2+} ion production becomes stepwisemore » ionization of Xe{sup +} ions. For an applied voltage of 800 V, the mass utilization efficiency is in the range of 0.8–1.1, and the current fraction of doubly charged ions varies between 0.1 and 0.2. Results show that the region of ion production of each species is located at the same place inside the thruster channel. Because collision processes mean free path is larger than the acceleration region, each type of ions experiences same potential drop, and ion energy distributions of singly and doubly charged are very similar.« less

  15. Cost-driven materials selection criteria for redox flow battery electrolytes

    NASA Astrophysics Data System (ADS)

    Dmello, Rylan; Milshtein, Jarrod D.; Brushett, Fikile R.; Smith, Kyle C.

    2016-10-01

    Redox flow batteries show promise for grid-scale energy storage applications but are presently too expensive for widespread adoption. Electrolyte material costs constitute a sizeable fraction of the redox flow battery price. As such, this work develops a techno-economic model for redox flow batteries that accounts for redox-active material, salt, and solvent contributions to the electrolyte cost. Benchmark values for electrolyte constituent costs guide identification of design constraints. Nonaqueous battery design is sensitive to all electrolyte component costs, cell voltage, and area-specific resistance. Design challenges for nonaqueous batteries include minimizing salt content and dropping redox-active species concentration requirements. Aqueous battery design is sensitive to only redox-active material cost and cell voltage, due to low area-specific resistance and supporting electrolyte costs. Increasing cell voltage and decreasing redox-active material cost present major materials selection challenges for aqueous batteries. This work minimizes cost-constraining variables by mapping the battery design space with the techno-economic model, through which we highlight pathways towards low price and moderate concentration. Furthermore, the techno-economic model calculates quantitative iterations of battery designs to achieve the Department of Energy battery price target of 100 per kWh and highlights cost cutting strategies to drive battery prices down further.

  16. The Implementation Internet of Things(IoT) Technology in Real Time Monitoring of Electrical Quantities

    NASA Astrophysics Data System (ADS)

    Despa, D.; Nama, G. F.; Muhammad, M. A.; Anwar, K.

    2018-04-01

    Electrical quantities such as Voltage, Current, Power, Power Factor, Energy, and Frequency in electrical power system tends to fluctuate, as a result of load changes, disturbances, or other abnormal states. The change-state in electrical quantities should be identify immediately, otherwise it can lead to serious problem for whole system. Therefore a necessity is required to determine the condition of electricity change-state quickly and appropriately in order to make effective decisions. Online monitoring of power distribution system based on Internet of Things (IoT) technology was deploy and implemented on Department of Mechanical Engineering University of Lampung (Unila), especially at three-phase main distribution panel H-building. The measurement system involve multiple sensors such current sensors and voltage sensors, while data processing conducted by Arduino, the measurement data stored in to the database server and shown in a real-time through a web-based application. This measurement system has several important features especially for realtime monitoring, robust data acquisition and logging, system reporting, so it will produce an important information that can be used for various purposes of future power analysis such estimation and planning. The result of this research shown that the condition of electrical power system at H-building performed unbalanced load, which often leads to drop-voltage condition

  17. Velocity overshoot decay mechanisms in compound semiconductor field-effect transistors with a submicron characteristic length

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jyegal, Jang, E-mail: jjyegal@inu.ac.kr

    Velocity overshoot is a critically important nonstationary effect utilized for the enhanced performance of submicron field-effect devices fabricated with high-electron-mobility compound semiconductors. However, the physical mechanisms of velocity overshoot decay dynamics in the devices are not known in detail. Therefore, a numerical analysis is conducted typically for a submicron GaAs metal-semiconductor field-effect transistor in order to elucidate the physical mechanisms. It is found that there exist three different mechanisms, depending on device bias conditions. Specifically, at large drain biases corresponding to the saturation drain current (dc) region, the velocity overshoot suddenly begins to drop very sensitively due to the onsetmore » of a rapid decrease of the momentum relaxation time, not the mobility, arising from the effect of velocity-randomizing intervalley scattering. It then continues to drop rapidly and decays completely by severe mobility reduction due to intervalley scattering. On the other hand, at small drain biases corresponding to the linear dc region, the velocity overshoot suddenly begins to drop very sensitively due to the onset of a rapid increase of thermal energy diffusion by electrons in the channel of the gate. It then continues to drop rapidly for a certain channel distance due to the increasing thermal energy diffusion effect, and later completely decays by a sharply decreasing electric field. Moreover, at drain biases close to a dc saturation voltage, the mechanism is a mixture of the above two bias conditions. It is suggested that a large secondary-valley energy separation is essential to increase the performance of submicron devices.« less

  18. High stress shallow moonquakes - Evidence for an initially totally molten moon

    NASA Technical Reports Server (NTRS)

    Binder, A. B.; Oberst, J.

    1985-01-01

    Thermoelastic stress calculations show that if the moon was initially molten only in the outer few hundred kilometers, as in the magma ocean model of the moon, the highlands crust should be aseismic. In contrast, if the moon was initially totally molten, high stress (1 to more than about 3 kbar), shallow (0 to about 6 km deep), compressional moonquakes should be occurring in the highlands crust. Calculations of the minimum stress drops made for the 28 observed shallow moonquakes suggest that 3 of them probably have stress drops in the kbar range. Thus, these very limited seismic data are consistent with the model that the moon was initially totally molten.

  19. How merging droplets jump off a superhydrophobic surface: Measurements and model

    NASA Astrophysics Data System (ADS)

    Mouterde, Timothée; Nguyen, Thanh-Vinh; Takahashi, Hidetoshi; Clanet, Christophe; Shimoyama, Isao; Quéré, David

    2017-11-01

    We investigate how drops merging on a nonwettable surface jump off this surface, for both symmetric and asymmetric coalescences. For this purpose, we design and build a microelectromechanical system sensor able to quantify forces down to the micro-Newton scale at a high acquisition rate (200 kHz). Using this device, we perform direct force measurements of self-propelled droplets coupled to high-speed imaging. Experimental data show that the total momentum of the drop after coalescence mainly depends on the size of the smaller drop. Exploiting this finding, we quantitatively predict the takeoff speed of jumping drop pairs and show how to correct the usual argument based on energy conservation.

  20. Evaluation of the New Version of the Laser-Optical Disdrometer, OTT Parsivel2

    NASA Technical Reports Server (NTRS)

    Tokay, Ali; Wolff, David B.; Petersen, Walter A.

    2014-01-01

    A comparative study of raindrop size distribution measurements has been conducted at NASA's Goddard Space Flight Center where the focus was to evaluate the performance of the upgraded laser-optical OTT Particle Size Velocity (Parsivel2; P2) disdrometer. The experimental setup included a collocated pair of tipping-bucket rain gauges, OTT Parsivel (P1) and P2 disdrometers, and Joss-Waldvogel (JW) disdrometers. Excellent agreement between the two collocated rain gauges enabled their use as a relative reference for event rain totals. A comparison of event total showed that the P2 had a 6%absolute bias with respect to the reference gauges, considerably lower than the P1 and JW disdrometers. Good agreement was also evident between the JW and P2 in hourly raindrop spectra for drop diameters between 0.5 and 4 mm. The P2 drop concentrations mostly increased toward small sizes, and the peak concentrations were mostly observed in the first three measurable size bins. The P1, on the other hand, underestimated small drops and overestimated the large drops, particularly in heavy rain rates. From the analysis performed, it appears that the P2 is an improvement over the P1 model for both drop size and rainfall measurements. P2 mean fall velocities follow accepted terminal fall speed relationships at drop sizes less than 1 mm. As a caveat, the P2 had approximately 1ms21 slower mean fall speed with respect to the terminal fall speed near 1 mm, and the difference between the mean measured and terminal fall speeds reduced with increasing drop size. This caveat was recognized as a software bug by the manufacturer and is currently being investigated.

  1. High Voltage TAL Performance

    NASA Technical Reports Server (NTRS)

    Jacobson, David T.; Jankovsky, Robert S.; Rawlin, Vincent K.; Manzella, David H.

    2001-01-01

    The performance of a two-stage, anode layer Hall thruster was evaluated. Experiments were conducted in single and two-stage configurations. In single-stage configuration, the thruster was operated with discharge voltages ranging from 300 to 1700 V. Discharge specific impulses ranged from 1630 to 4140 sec. Thruster investigations were conducted with input power ranging from 1 to 8.7 kW, corresponding to power throttling of nearly 9: 1. An extensive two-stage performance map was generated. Data taken with total voltage (sum of discharge and accelerating voltage) constant revealed a decrease in thruster efficiency as the discharge voltage was increased. Anode specific impulse values were comparable in the single and two-stage configurations showing no strong advantage for two-stage operation.

  2. Evaluation of wheelchair drop seat crashworthiness.

    PubMed

    Bertocci, G; Ha, D; van Roosmalen, L; Karg, P; Deemer, E

    2001-05-01

    Wheelchair seating crash performance is critical to protecting wheelchair users who remain seated in their wheelchairs during transportation. Relying upon computer simulation and sled testing seat loads associated with a 20 g/48 kph (20 g/30 mph) frontal impact and 50th percentile male occupant were estimated to develop test criteria. Using a static test setup we evaluated the performance of various types of commercially available drop seats against the loading test criteria. Five different types of drop seats (two specimens each) constructed of various materials (i.e. plastics, plywood, metal) were evaluated. Two types of drop seats (three of the total 10 specimens) met the 16650 N (3750 lb) frontal impact test criteria. While additional validation of the test protocol is necessary, this study suggests that some drop seat designs may be incapable of withstanding crash level loads.

  3. A Comparison of Transient-Radiation Effects Vulnerability Analysis with Experimental Results

    DTIC Science & Technology

    1982-12-01

    Electronic Equipment to TRE: TII-22/TG, TD -352/U, TD -353/U, SN-421/TPX-50, C-7651, and RT-9031/TPX-50 (U), Harry Diamond Laboratories, HDL-PR-80-3 (July...shown in the figure, the output voltage rapidly drops off once 1Q3 x 8 Q2 becomes less than 200. The failure threshold was set at 170. 1.0. 1.0 , o /t...5) P. A. Trimmer, Vulnerability of Army Electronic Aquipment to TRE: TH-22/TG, TD -352/U, TD -353/U, SN-421/TPX-50, C-7651, and RT- 9031/TPX-50 (U

  4. The judgement of simultaneous commutation failure in HVDC about hierarchical connection to AC grid

    NASA Astrophysics Data System (ADS)

    Li, Ming; Song, Xinli; Huang, Daoshan; Liu, Wenzhuo; Zhao, Shutao; Ye, Xiaohui; Meng, Hang

    2017-09-01

    The hierarchical connection to AC grid at inverter sides in UHVDC has been take in several projects. This paper introduced the frame of the connection mode in hierarchical access system and compared it with the traditional one at the case of HVDC-Cigre. Then the criterion of commutation failure according to the same valves current was deduced. In order to verify the accuracy of the criterion, this paper used PSD-BPA (Bonneville Power Administration) to simulate the setting voltage drop in the East China power grid and certified the correctness of the formula.

  5. Fluid flow electrophoresis in space

    NASA Technical Reports Server (NTRS)

    Griffin, R. N.

    1975-01-01

    Four areas relating to free-flow electrophoresis in space were investigated. The first was the degree of improvement over earthbound operations that might be expected. The second area of investigation covered the problems in developing a flowing buffer electrophoresis apparatus. The third area of investigation was the problem of testing on the ground equipment designed for use in space. The fourth area of investigation was the improvement to be expected in space for purification of biologicals. The results of some ground-based experiments are described. Other studies included cooling requirements in space, fluid sealing techniques, and measurement of voltage drop across membranes.

  6. Thermionic energy conversion technology - Present and future

    NASA Technical Reports Server (NTRS)

    Shimada, K.; Morris, J. F.

    1977-01-01

    Aerospace and terrestrial applications of thermionic direct energy conversion and advances in direct energy conversion (DEC) technology are surveyed. Electrode materials, the cesium plasma drop (the difference between the barrier index and the collector work function), DEC voltage/current characteristics, conversion efficiency, and operating temperatures are discussed. Attention is centered on nuclear reactor system thermionic DEC devices, for in-core or out-of-core operation. Thermionic fuel elements, the radiation shield, power conditions, and a waste heat rejection system are considered among the thermionic DEC system components. Terrestrial applications include topping power systems in fossil fuel and solar power generation.

  7. AlGaInP light-emitting diodes with SACNTs as current-spreading layer

    PubMed Central

    2014-01-01

    Transparent conductive current-spreading layer is important for quantum efficiency and thermal performance of light-emitting diodes (LEDs). The increasing demand for tin-doped indium oxide (ITO) caused the price to greatly increase. Super-aligned carbon nanotubes (SACNTs) and Au-coated SACNTs as current-spreading layer were applied on AlGaInP LEDs. The LEDs with Au-coated SACNTs showed good current spreading effect. The voltage bias at 20 mA dropped about 0.15 V, and the optical power increased about 10% compared with the LEDs without SACNTs. PMID:24712527

  8. Coupling of Mechanical Behavior of Lithium Ion Cells to Electrochemical-Thermal (ECT) Models for Battery Crush

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Chao; Santhanagopalan, Shriram; Pesaran, Ahmad

    Vehicle crashes can lead to crushing of the battery, damaging lithium ion battery cells and causing local shorts, heat generation, and thermal runaway. Simulating all the physics and geometries at the same time is challenging and takes a lot of effort; thus, simplifications are needed. We developed a material model for simultaneously modeling the mechanical-electrochemical-thermal behavior, which predicted the electrical short, voltage drop, and thermal runaway behaviors followed by a mechanical abuse-induced short. The effect of short resistance on the battery cell performance was studied.

  9. Numerical Model for Predicting and Managing Heat Dissipation from a Neural Probe

    DTIC Science & Technology

    2013-05-10

    Distance from Probe Centerline [m] x ‐  3D  Model y ‐  3D  Model r ‐ 2D Model 12 difficult, especially on a micro-scale level. For this reason...of the screws and nuts 180 m across. 20 were of plastic construction. An aluminum sample holder was constructed by the USNA Fabrication Lab...voltage drop across the reference resistor. C. Biosimulant Gel At first, a hydroxyethyl cellulose gel was considered for use as the biosimulant gel, but

  10. Improving Ionic Conductivity and Lithium-Ion Transference Number in Lithium-Ion Battery Separators.

    PubMed

    Zahn, Raphael; Lagadec, Marie Francine; Hess, Michael; Wood, Vanessa

    2016-12-07

    The microstructure of lithium-ion battery separators plays an important role in separator performance; however, here we show that a geometrical analysis falls short in predicting the lithium-ion transport in the electrolyte-filled pore space. By systematically modifying the surface chemistry of a commercial polyethylene separator while keeping its microstructure unchanged, we demonstrate that surface chemistry, which alters separator-electrolyte interactions, influences ionic conductivity and lithium-ion transference number. Changes in separator surface chemistry, particularly those that increase lithium-ion transference numbers can reduce voltage drops across the separator and improve C-rate capability.

  11. Theory of passive proton conductance in lipid bilayers.

    PubMed

    Nagle, J F

    1987-10-01

    The large permeability of lipid bilayers to protons compared to other small ions calls for a special proton transport mechanism. At the present time, only mechanisms involving transient hydrogen-bonded chains of water can account for the experimental result that the conductance is nearly independent of pH. Three models involving transient hydrogen-bonded chains are discussed, including an outline of the kinetic calculations that lead to predictions of current versus voltage drop and current versus pH differences. These calculations can be compared to experiment to determine which, if any, of these models pertains to lipid bilayers.

  12. Efficacy and safety of oral tranexamic acid in total knee arthroplasty: A systematic review and meta-analysis.

    PubMed

    Guo, Peipei; He, Zike; Wang, Yanhua; Gao, Fuqiang; Sun, Wei; Guo, Wanshou; Li, Zirong; Cheng, Liming

    2018-05-01

    Tranexamic acid (TXA) is an antifibrinolytic drug widely used as a blood-sparing technique in total knee arthroplasty (TKA), and it is usually administrated by intravenous or intraarticular injection. Recently, the oral form of TXA has been applied in TKA patients. However, there is no final consensus regarding the effectiveness and safety of oral TXA. The purpose of this systematic review and meta-analysis of randomized controlled trials (RCTs) was to evaluate the efficacy and safety of oral TXA versus control for blood loss after TKA. We searched PubMed, Embase, Medline, Web of Science, and Cochrane Library databases for relevant studies through August 2017. The mean difference (MD) of total blood loss, hemoglobin (Hb) drop, hematocrit (Hct), drain output, and risk difference (RD) of transfusion rate and thromboembolic complications in the TXA and control groups were pooled throughout the study. The outcomes were pooled by Stata 12.0. A total of 5 RCTs (608 patients) were included in this study. All the included studies were randomized and the quality of included studies was relatively high. The pooled results indicated that the oral TXA group had significantly less Hb drop (standardized mean difference [SMD], -0.936; 95% confidence intervals [CI], -1.118,-0.754), Hct drop (SMD, -0.693; 95% CI, -1.113, -0.274), and drain output (SMD, -0.793; 95% CI, -0.959, -0.628) than the control group. No statistically significant differences were found in transfusion rate and the incidence of thromboembolic complications between the 2 groups. Total blood loss could not be evaluated for the insufficient date. Our meta-analysis suggested that the administration of oral TXA provided significantly better results with respect to Hb drop, Hct drop, and drain output without increasing the transfusion rate and the risk of thromboembolic complications after TKA. Nevertheless, our current study with some limitations such as the small sample size only provided limited quality of evidence, confirmation from further meta-analysis with large-scale, well-designed RCTs is required.

  13. Drop size distributions and related properties of fog for five locations measured from aircraft

    NASA Technical Reports Server (NTRS)

    Zak, J. Allen

    1994-01-01

    Fog drop size distributions were collected from aircraft as part of the Synthetic Vision Technology Demonstration Program. Three west coast marine advection fogs, one frontal fog, and a radiation fog were sampled from the top of the cloud to the bottom as the aircraft descended on a 3-degree glideslope. Drop size versus altitude versus concentration are shown in three dimensional plots for each 10-meter altitude interval from 1-minute samples. Also shown are median volume radius and liquid water content. Advection fogs contained the largest drops with median volume radius of 5-8 micrometers, although the drop sizes in the radiation fog were also large just above the runway surface. Liquid water content increased with height, and the total number of drops generally increased with time. Multimodal variations in number density and particle size were noted in most samples where there was a peak concentration of small drops (2-5 micrometers) at low altitudes, midaltitude peak of drops 5-11 micrometers, and high-altitude peak of the larger drops (11-15 micrometers and above). These observations are compared with others and corroborate previous results in fog gross properties, although there is considerable variation with time and altitude even in the same type of fog.

  14. Inverter Load Rejection Over-Voltage Testing: SolarCity CRADA Task 1a Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, A.; Hoke, A.; Chakraborty, S.

    Various interconnection challenges exist when connecting distributed PV into the electrical distribution grid in terms of safety, reliability, and stability of electric power systems. One of the urgent areas for additional research - as identified by inverter manufacturers, installers, and utilities - is the potential for transient over-voltage from PV inverters. In one stage of a cooperative tests were repeated a total of seven times. The maximum over-voltage measured in any test did not exceed 200% of nominal, and typical over-voltage levels were significantly lower. The total voltage duration and the maximum continuous time above each threshold are presented here,more » as well as the time to disconnect for each test. Finally, we present a brief investigation into the effect of DC input voltage as well as a series of no-load tests. This report describes testing conducted at NREL to determine the duration and magnitude of transient over-voltages created by several commercial PV inverters during load-rejection conditions. For this work, a test plan that is currently under development by the Forum on Inverter Grid Integration Issues (FIGII) has been implemented in a custom test setup at NREL. Through a cooperative research and development agreement, NREL is working with SolarCity to address two specific types of transient overvoltage: load rejection overvoltage (LRO) and ground fault overvoltage (GFO). Additional partners in this effort include the Hawaiian Electric Companies, Northern Plains Power Technologies, and the Electric Power Research Institute.« less

  15. Radiation tolerant back biased CMOS VLSI

    NASA Technical Reports Server (NTRS)

    Maki, Gary K. (Inventor); Gambles, Jody W. (Inventor); Hass, Kenneth J. (Inventor)

    2003-01-01

    A CMOS circuit formed in a semiconductor substrate having improved immunity to total ionizing dose radiation, improved immunity to radiation induced latch up, and improved immunity to a single event upset. The architecture of the present invention can be utilized with the n-well, p-well, or dual-well processes. For example, a preferred embodiment of the present invention is described relative to a p-well process wherein the p-well is formed in an n-type substrate. A network of NMOS transistors is formed in the p-well, and a network of PMOS transistors is formed in the n-type substrate. A contact is electrically coupled to the p-well region and is coupled to first means for independently controlling the voltage in the p-well region. Another contact is electrically coupled to the n-type substrate and is coupled to second means for independently controlling the voltage in the n-type substrate. By controlling the p-well voltage, the effective threshold voltages of the n-channel transistors both drawn and parasitic can be dynamically tuned. Likewise, by controlling the n-type substrate, the effective threshold voltages of the p-channel transistors both drawn and parasitic can also be dynamically tuned. Preferably, by optimizing the threshold voltages of the n-channel and p-channel transistors, the total ionizing dose radiation effect will be neutralized and lower supply voltages can be utilized for the circuit which would result in the circuit requiring less power.

  16. Asymptotic analysis of corona discharge from thin electrodes

    NASA Technical Reports Server (NTRS)

    Durbin, P. A.

    1986-01-01

    The steady discharge of a high-voltage corona is analyzed as a singular perturbation problem. The small parameter is the ratio of the length of the ionization region to the total gap length. By this method, current versus voltage characteristics can be calculated analytically.

  17. Design and test of current limiting modules using YBCO-coated conductors

    NASA Astrophysics Data System (ADS)

    Schmidt, W.; Gamble, B.; Kraemer, H.-P.; Madura, D.; Otto, A.; Romanosky, W.

    2010-01-01

    Within the cooperation between American Superconductor Corporation (AMSC) and Siemens Corporate Technology we have investigated the fault current limiting performance of YBCO-coated conductors (also called second-generation or 2G HTS wires) stabilized with stainless steel laminates. Design rules for the length and width of the wire depending on utility grid requirements have been established. Bifilar coils have been manufactured and tested with a typical limitation period of 50 ms under stepwise increasing voltage loads to determine the maximum temperature the wires can withstand without degradation. Coils have been assembled into limiter modules demonstrating uniform tripping of the individual coils and recovery within seconds. At present this cooperation is proceeding within a joint project funded by the US Department of Energy (DOE) that encompasses the design, construction and testing of a 115 kV FCL for power transmission within a time frame of 4-5 years, and additional partners. Besides AMSC and Siemens, Nexans contributes the high voltage terminations and Los Alamos National Lab investigates the ac losses. Installation and testing are planned for a Southern California Edison substation. The module planned for the transmission voltage application consists of 63 horizontally arranged coils connected in parallel and series to account for a rated current of 1.2 kArms and voltage of 31 kVrms plus margins. The rated voltage of the module is considerably lower than the line to ground voltage in the 115 kV grid owing to our shunted limiter concept. The shunt reactor connected in parallel to the module outside the cryostat allows for adjustment of the limited current and reduces voltage drop across the module in case of a fault. The fault current reduction ratio is 42% for our present design. A subscale module comprising six full-size coils has been assembled and tested recently to validate the coil performance and coil winding technique. The module had a critical current of 425 ADC and a nominal power of 2.52 MV A at 77 K. A complete series of tests with applied voltage up to 8.4 kVrms, prospective short circuit current up to 26.6 kArms and variation of phase angle at initiation of the fault has been performed. After more than 40 switching tests the critical current of the module remained unchanged, indicating that no degradation of the wire occurred.

  18. Stable, fast and high-energy-density LiCoO2 cathode at high operation voltage enabled by glassy B2O3 modification

    NASA Astrophysics Data System (ADS)

    Zhou, Aijun; Wang, Weihang; Liu, Qin; Wang, Yi; Yao, Xu; Qing, Fangzhu; Li, Enzhu; Yang, Tingting; Zhang, Long; Li, Jingze

    2017-09-01

    In this work, commercial LiCoO2 is modified with a glassy B2O3 by solution mixing with H3BO3 followed by post-calcination in order to enhance its high-voltage electrochemical performance. The glassy B2O3 coating/additive is believed to serve as an effective physiochemical buffer and protection between LiCoO2 and liquid electrolyte, which can suppress the high-voltage induced electrolyte decomposition and active material dissolution. During the early cycling and due to the electrochemical force, the as-coated B2O3 glasses which have 3D open frameworks tend to accommodate some mobile Li+ and form a more chemically-resistant and ion-conductive lithium boron oxide (LBO) interphase as a major component of the solid electrolyte interphase (SEI), which consequently enables much easier Li+ diffusion/transfer at the solid-liquid interfaces upon further cycling. Due to the synergetic effects of B2O3 coating/modification, the high-voltage capacity and energy density of the B2O3-modified LiCoO2 cathode are promisingly improved by 35% and 30% after 100 cycles at 1 C within 3.0-4.5 V vs. Li/Li+. Meanwhile, the high-rate performance of the B2O3-modified electrode is even more greatly improved, showing a capacity of 105 mAh g-1 at 10 C while the bare electrode has dropped to no more than 30 mAh g-1 under this rate condition.

  19. Avulsion of the fibular head post-total knee replacement.

    PubMed

    Phadnis, Ashish; Johnston, Phillip; Glasgow, Malcom

    2007-11-01

    We report a case of an avulsion of part of the fibular head during a primary total knee replacement for osteoarthritis. Post-operatively the patient developed a foot-drop. However, there was no clinically demonstrable instability of the knee. The patient was managed conservatively, the foot-drop recovered completely and the knee remained clinically stable. We observed that excessive hyperextension and/or a varus strain on the knee during pressurisation while cementing could have led to the injury. We advise caution while using this manoeuvre for pressurisation. This is the first injury of its kind reported in the literature.

  20. Susceptibility measurements on the superconducting properties of Nb-Ge alloys

    NASA Technical Reports Server (NTRS)

    Rathz, T. J.

    1981-01-01

    A susceptibility apparatus to measure superconducting properties of samples made in the MSFC Drop Tube was used to measure the transition temperature (Tc) and susceptibilities of Nb and Nb Ge Alloys prepared in bulk spherical (2-4 mm diameter) form using a 32 m drop tube in which containerless low gravity solidification could take place. Results indicate that a drop tube processing environment was beneficial for increasing the Tc of the superconducting phase of the material over that of arc melted material. The increase in Tc is found to be related to the amount of solidification of the total sample that took place before reaching the bottom of the drop tube. In phase and quadrature phase measurements of the specimen's susceptibility indicated that some improvement in homogeneity takes place in drop tube processing. These phase measurements also indicated little or no shielding of a lower Tc phase by a higher Tc filamentary structure.

  1. Space Shuttle Solid Rocket Booster Decelerator Subsystem Drop Test 3 - Anatomy of a failure

    NASA Technical Reports Server (NTRS)

    Runkle, R. E.; Woodis, W. R.

    1979-01-01

    A test failure dramatically points out a design weakness or the limits of the material in the test article. In a low budget test program, with a very limited number of tests, a test failure sparks supreme efforts to investigate, analyze, and/or explain the anomaly and to improve the design such that the failure will not recur. The third air drop of the Space Shuttle Solid Rocket Booster Recovery System experienced such a dramatic failure. On air drop 3, the 54-ft drogue parachute was totally destroyed 0.7 sec after deployment. The parachute failure investigation, based on analysis of drop test data and supporting ground element test results is presented. Drogue design modifications are also discussed.

  2. Undercooling measurement in a low-gravity containerless environment

    NASA Technical Reports Server (NTRS)

    Robinson, M. B.

    1981-01-01

    A technique is described for measuring the amount of undercooling for samples processed in a low-gravity containerless environment. The time of undercooling is determined by measuring the time of cooling before nucleation and recalescence by two infrared detectors. Once the cooling curve for each drop is calculated, the amount of undercooling can then be found. The technique is demonstrated by measuring the amount of undercooling for drops of pure niobium and select compositions of the niobium-germanium alloy system while free falling in a 32 n evacuated drop tube. The total hemispherical emissivities and specific heats for these materials were measured using a high-temperature containerless calorimeter. An overview of the effect of undercooling on drops of niobium and niobium-germanium is given.

  3. A Gain-Programmable Transit-Time-Stable and Temperature-Stable PMT Voltage Divider

    NASA Astrophysics Data System (ADS)

    Liu, Yaqiang; Li, Hongdi; Wang, Yu; Xing, Tao; Xie, Shuping; Uribe, J.; Baghaei, H.; Ramirez, R.; Kim, Soonseok; Wong, Wai-Hoi

    2004-10-01

    A gain-programmable, transit-time-stable, temperature-stable photomultiplier (PMT) voltage divider design is described in this paper. The signal-to-noise ratio can be increased by changing a PMT gain directly instead of adjusting the gain of the preamplifier. PMT gain can be changed only by adjusting the voltages for the dynodes instead of changing the total high voltage between the anode and the photocathode, which can cause a significant signal transit-time variation that cannot be accepted by an application with a critical timing requirement, such as positron emission tomography (PET) or time-of-flight (TOF) detection/PET. The dynode voltage can be controlled by a digital analog converter isolated with a linear optocoupler. The optocoupler consists of an infrared light emission diode (LED) optically coupled with two phototransistors, and one is used in a servo feedback circuit to control the LED drive current for compensating temperature characteristics. The results showed that a six times gain range could be achieved; the gain drift was <0.5% over a 20/spl deg/C temperature range; 250 ps transit-time variation was measured over the entire gain range. A compact print circuit board (PCB) for the voltage divider integrated with a fixed-gain preamplifier has been designed and constructed. It can save about $30 per PMT channel compared with a commercial PMT voltage divider along with a variable gain amplifier. The preamplifier can be totally disabled, therefore in a system with a large amount of PMTs, only one channel can be enabled for calibrating the PMT gain. This new PMT voltage divider design is being applied to our animal PET camera and TOF/PET research.

  4. Experimental verification of gain drop due to general ion recombination for a carbon-ion pencil beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tansho, Ryohei, E-mail: r-tansho@nirs.go.jp; Furukawa, Takuji; Hara, Yousuke

    Purpose: Accurate dose measurement in radiotherapy is critically dependent on correction for gain drop, which is the difference of the measured current from the ideal saturation current due to general ion recombination. Although a correction method based on the Boag theory has been employed, the theory assumes that ionized charge density in an ionization chamber (IC) is spatially uniform throughout the irradiation volume. For particle pencil beam scanning, however, the charge density is not uniform, because the fluence distribution of a pencil beam is not uniform. The aim of this study was to verify the effect of the nonuniformity ofmore » ionized charge density on the gain drop due to general ion recombination. Methods: The authors measured the saturation curve, namely, the applied voltage versus measured current, using a large plane-parallel IC and 24-channel parallel-plate IC with concentric electrodes. To verify the effect of the nonuniform ionized charge density on the measured saturation curve, the authors calculated the saturation curve using a method which takes into account the nonuniform ionized charge density and compared it with the measured saturation curves. Results: Measurement values of the different saturation curves in the different channels of the concentric electrodes differed and were consistent with the calculated values. The saturation curves measured by the large plane-parallel IC were also consistent with the calculation results, including the estimation error of beam size and of setup misalignment. Although the impact of the nonuniform ionized charge density on the gain drop was clinically negligible with the conventional beam intensity, it was expected that the impact would increase with higher ionized charge density. Conclusions: For pencil beam scanning, the assumption of the conventional Boag theory is not valid. Furthermore, the nonuniform ionized charge density affects the prediction accuracy of gain drop when the ionized charge density is increased by a higher dose rate and/or lower beam size.« less

  5. The incept of ejection from a fresh Taylor cone and subsequent evolution

    NASA Astrophysics Data System (ADS)

    Lopez-Herrera, Jose M.; Ganan-Calvo, Alfonso

    2017-11-01

    Within a certain range of applied voltages, a pendant drop suddenly subject to an intense electric field develops a cusp from which a fast liquid ligament issues. The incept of this process has common roots with other related phenomena like the Worthington jets, the jet issued after surface bubble bursting or the impact of a drop on a liquid pool. This is experimentally and numerically demonstrated. However, given the electrohydrodynamic nature of the driver in the formation of a Taylor cone, a number of electrokinetic processes take place in the rapid tapering flow, whose characteristic times should be carefully compared to the ones of the flow. As a result, universal scaling laws for the size and charge of the top drop have been obtained. Subsequently, sustaining the applied electric field, the ejection continues and the issuing liquid ligament releases a train of droplets of varying size and charge. Under appropriate conditions and if the liquid suctioned by the electric field is replenished, the system reaches a (quasi)steady state asymptotically. The degree of compliance of the size and charge of those subsequent droplets with previously proposed scaling laws of steady Taylor cone-jets has been studied. Computational code Gerris and an extended electrokinetic module is used. This work was supported by the Ministerio de Economia y Competitividad, Plan Estatal 2013-2016 Retos, project DPI2016-78887-C3-1-R.

  6. Plasma contactor research, 1990

    NASA Technical Reports Server (NTRS)

    Williams, John D.; Wilbur, Paul J.

    1991-01-01

    Emissive and Langmuir probes were used to measure plasma potential profiles, plasma densities, electron energy distributions, and plasma noise levels near a hollow cathode-based plasma contactor emitting electrons. The effects of electron emission current (100 to 1500 mA) and contactor flowrate (2 to 10 sccm (Xenon)) on these data are examined. Retarding potential analyzer (RPA) measurements showing that high energy ions generally stream from a contactor along with the electrons being emitted are also presented, and a mechanism by which this occurs is postulated. This mechanism, which involves a high rate of ionization induced between electrons and atoms flowing together from the hollow cathode orifice, results in a region of high positive space charge and high positive potential. Langmuir and RPA probe data suggests that both electrons and ions expand spherically from this potential hill region. In addition to experimental observations, a simple one-dimensional model which describes the electron emission process and predicts the phenomena just mentioned is presented and is shown to agree qualitatively with these observations. Experimental results of the first stage of bilateral cooperation with the Italian Institute of Interplanetary Space Physics (IFSI CNR) are presented. Sharp, well-defined double layers were observed downstream of a contactor collecting electrons from an ambient plasma created in the IFSI Facility. The voltage drop across these double layers was observed to increase with the current drawn from the ambient plasma. This observation, which was not as clear in previous IFSI tests conducted at higher neutral pressures, is in agreement with previous experimental observations made at both Colorado State University and NASA Lewis Research Center. Greater double layer voltage drops, multiple double layers, and higher noise levels in the region near the double layers were also observed when a magnetic field was imposed and oriented perpendicular to the line joining the contactor and simulator.

  7. Pulsed arc plasma jet synchronized with drop-on-demand dispenser

    NASA Astrophysics Data System (ADS)

    Mavier, F.; Lemesre, L.; Rat, V.; Bienia, M.; Lejeune, M.; Coudert, J.-F.

    2017-04-01

    This work concerns with the liquid injection in arc plasma spraying for the development of finely structured ceramics coatings. Nanostructured coatings can be now achieved with nanopowders dispersed in a liquid (SPS: Suspension Plasma Spraying) or with a salt dissolved into a liquid (SPPS: Solution Precursor Plasma Spraying) injected into the plasma jet. Controlling electric arc instabilities confined in non-transferred arc plasma torch is therefore a key issue to get reproducible coating properties. Adjustment of parameters with a mono-cathode arc plasma allows a new resonance mode called “Mosquito”. A pulsed arc plasma producing a periodic regular voltage signal with modulation of enthalpy is obtained. The basic idea is to synchronize the injection system with the arc to introduce the liquid material in each plasma oscillation in the same conditions, in order to control the plasma treatment of the material in-fly. A custom-developed pulsed arc plasma torch is used with a drop-on-demand dispenser triggered by the arc voltage. A delay is added to adjust the droplets emission time and their penetration into the plasma gusts. Indeed, the treatment of droplets is also shown to be dependent on this injection delay. A TiO2 suspension and an aqueous solution of aluminium nitrate were optimized to get ejectable inks forming individual droplets. The feasibility of the process was demonstrated for SPS and SPPS techniques. Coatings from the suspension and the solution were achieved. First synchronized sprayings show a good penetration of the droplets into the plasma. Coatings show a fine structure of cauliflowers shapes. The synchronization of the ejection allows a control of morphology and a better deposition efficiency. Further investigations will find the optimal operating parameters to show the full potential of this original liquid injection technique.

  8. Biasing experiments on the Advanced Toroidal Facility

    NASA Astrophysics Data System (ADS)

    Uckan, T.; Isler, R. C.; Jernigan, T. C.; Lyon, J. F.; Mioduszewski, P. K.; Murakami, M.; Rasmussen, D. A.; Wilgen, J. B.; Aceto, S. C.; Zielinski, J. J.

    1992-09-01

    Biasing experiments have been carried out in 1 T plasmas with approximately 200 kW of electron cyclotron heating (ECH) in the current-fire Advanced Toroidal Facility (ATF) torsatron. Two rail limiters, one at the top and one at the bottom of the device, located at the last closed flux surface (LCFS), are, biased at positive and negative potentials with respect to the vacuum vessel. When the limiters are positively biased at up to 300 V and the plasma density is controlled with a significantly reduced gas feed, the H(sub alpha) radiation from both the limiter and the wall drops, indicating reduced particle recycling as a result of improved particle confinement. For bias voltages around +100 V, there is almost no change of plasma stored energy W(sub p), but W(sub p) then drops with the higher biasing voltages. Positive biasing has caused the core plasma density profile to become peaked and the electric field to become more negative inside the LCFS. At the same time, edge plasma fluctuations are reduced significantly and their power spectrum becomes less broad. The propagation direction of these electrostatic fluctuations reverses to the ion diamagnetic direction, and their wavelengths become longer. The resulting fluctuation-induced particle flux is also reduced. Power deposition on the limiters is lower as a result of reduced edge plasma density and temperature. Negative biasing yields somewhat less improvement in the particle confinement while having almost no apparent effect on W(sub p) or on the core and the edge plasma density and temperature profiles. Simultaneous measurements of the plasma potential profile indicate almost no significant change. Biasing has almost no effect on the intrinsic impurity levels in the plasma.

  9. Single-limb drop landing biomechanics in active individuals with and without a history of anterior cruciate ligament reconstruction: A total support analysis.

    PubMed

    Pozzi, Federico; Di Stasi, Stephanie; Zeni, Joseph A; Barrios, Joaquin A

    2017-03-01

    The purpose of this study was to characterize the magnitude and distribution of the total support moment during single-limb drop landings in individuals after anterior cruciate ligament reconstruction compared to a control group. Twenty participants after reconstruction and twenty control participants matched on sex, limb dominance and activity level were recruited. Motion analysis was performed during a single-limb drop landing task. Total support moment was determined by summing the internal extensor moments at the ankle, knee, and hip. Each relative joint contribution to the total support moment was calculated by dividing each individual contribution by the total support moment. Data were captured during a landing interval that started at initial contact and ended at the lowest vertical position of the pelvis. Data were then time-normalized and indexed at 25, 50, 75, and 100% of the landing interval. No between-group differences for total support moment magnitude were observed. At both 75% and 100% of the landing, the relative contribution of the knee joint was lower in those with a history of surgery (p<0.001). At the same instances, the relative contribution to the total support moment by the hip joint was greater in those with a history of surgery (p=0.004). In active participants after anterior cruciate ligament reconstruction, relative contributions to anti-gravity support of the center of mass shifted from the knee to the hip joint during single-limb landing, which became evident towards the end of the landing interval. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Current flow and pair creation at low altitude in rotation-powered pulsars' force-free magnetospheres: space charge limited flow

    NASA Astrophysics Data System (ADS)

    Timokhin, A. N.; Arons, J.

    2013-02-01

    We report the results of an investigation of particle acceleration and electron-positron plasma generation at low altitude in the polar magnetic flux tubes of rotation-powered pulsars, when the stellar surface is free to emit whatever charges and currents are demanded by the force-free magnetosphere. We apply a new 1D hybrid plasma simulation code to the dynamical problem, using Particle-in-Cell methods for the dynamics of the charged particles, including a determination of the collective electrostatic fluctuations in the plasma, combined with a Monte Carlo treatment of the high-energy gamma-rays that mediate the formation of the electron-positron pairs. We assume the electric current flowing through the pair creation zone is fixed by the much higher inductance magnetosphere, and adopt the results of force-free magnetosphere models to provide the currents which must be carried by the accelerator. The models are spatially one dimensional, and designed to explore the physics, although of practical relevance to young, high-voltage pulsars. We observe novel behaviour (a) When the current density j is less than the Goldreich-Julian value (0 < j/jGJ < 1), space charge limited acceleration of the current carrying beam is mild, with the full Goldreich-Julian charge density comprising the charge densities of the beam and a cloud of electrically trapped particles with the same sign of charge as the beam. The voltage drops are of the order of mc2/e, and pair creation is absent. (b) When the current density exceeds the Goldreich-Julian value (j/jGJ > 1), the system develops high voltage drops (TV or greater), causing emission of curvature gamma-rays and intense bursts of pair creation. The bursts exhibit limit cycle behaviour, with characteristic time-scales somewhat longer than the relativistic fly-by time over distances comparable to the polar cap diameter (microseconds). (c) In return current regions, where j/jGJ < 0, the system develops similar bursts of pair creation. These discharges are similar to those encountered in previous calculations by Timokhin of pair creation when the surface has a high work function and cannot freely emit charge. In cases (b) and (c), the intermittently generated pairs allow the system to simultaneously carry the magnetospherically prescribed currents and adjust the charge density and average electric field to force-free conditions. We also elucidate the conditions for pair creating beam flow to be steady (stationary with small fluctuations in the rotating frame), finding that such steady flows can occupy only a small fraction of the current density parameter space exhibited by the force-free magnetospheric model. The generic polar flow dynamics and pair creation are strongly time dependent. The model has an essential difference from almost all previous quantitative studies, in that we sought the accelerating voltage (with pair creation, when the voltage drops are sufficiently large; without, when they are small) as a function of the applied current. The 1D results described here characterize the dependence of acceleration and pair creation on the magnitude and sign of current. The dependence on the spatial distribution of the current is a multi-dimensional problem, possibly exhibiting more chaotic behaviour. We briefly outline possible relations of the electric field fluctuations observed in the polar flows (both with and without pair creation discharges) to direct emission of radio waves, as well as revive the possible relation of the observed limit cycle behaviour to microstructure in the radio emission. Actually modelling these effects requires the multi-dimensional treatment, to be reported in a later paper.

  11. Experimental Investigation of Oscillatory Flow Pressure and Pressure Drop Through Complex Geometries

    NASA Technical Reports Server (NTRS)

    Ibrahim, Mounir B.; Wang, Meng; Gedeon, David

    2005-01-01

    A series of experiments have been performed to investigate the oscillatory flow pressure and pressure drop through complex geometries. These experiments were conducted at the CSU-SLRE facility which is a horizontally opposed, two-piston, single-acting engine with a split crankshaft driving mechanism. Flow through a rectangular duct, with no insert (obstruction), was studied first. Then four different inserts were examined: Abrupt, Manifold, Diverging Short and Diverging Long. The inserts were mounted in the center of the rectangular duct to represent different type of geometries that could be encountered in Stirling machines. The pressure and pressure drop of the oscillating flow was studied for: 1) different inserts, 2) different phase angle between the two pistons of the engine (zero, 90 lead, 180, and 90 lag), and 3) for different piston frequencies (5, 10, 15, and 20 Hz). It was found that the pressure drop of the oscillatory flow increases with increasing Reynolds number. The pressure drop was shown to be mainly due to the gas inertia for the case of oscillatory flow through a rectangular duct with no insert. On the other hand, for the cases with different inserts into the rectangular duct, the pressure drop has three sources: inertia, friction, and local losses. The friction pressure drop is only a small fraction of the total pressure drop. It was also shown that the dimensionless pressure drop decreases with increasing kinetic Reynolds number.

  12. Method for reducing fuel cell output voltage to permit low power operation

    DOEpatents

    Reiser, Carl A.; Landau, Michael B.

    1980-01-01

    Fuel cell performance is degraded by recycling a portion of the cathode exhaust through the cells and, if necessary, also reducing the total air flow to the cells for the purpose of permitting operation below a power level which would otherwise result in excessive voltage.

  13. Structure and Dynamics of Interfaces: Drops and Films

    NASA Technical Reports Server (NTRS)

    Mann, J. Adin, Jr.; Mann, Elizabeth K.; Meyer, William V.; Neumann, A. Wilhelm; Tavana, Hossein

    2015-01-01

    We aim to acquire measurements of the structure and dynamics of certain liquid-fluid interfaces using an ensemble of techniques in collaboration: (1) Total internal reflection (TIR) Surface light scattering spectroscopy (SLSS), (2) Brewster angle microscopy (BAM), and (3) Drop-shape analysis. SLSS and BAM can be done on a shared interfacial footprint. Results using a 50-50 mixture of pentane-isohexane, which extends the range of NASA's Confined Vapor Bubble (CVB) experiment, yield surface tension results that differ from the expected Langmuir Fit. These results were confirmed using both the SLSS and drop-shape analysis approaches.

  14. Comparison of Raindrop Size Distribution Measurements by Collocated Disdrometers

    NASA Technical Reports Server (NTRS)

    Tokay, Ali; Petersen, Walter A.; Gatlin, Patrick; Wingo, Matthew

    2013-01-01

    An impact-type Joss-Waldvogel disdrometer (JWD), a two-dimensional video disdrometer (2DVD), and a laser optical OTT Particle Size and Velocity (PARSIVEL) disdrometer (PD) were used to measure the raindrop size distribution (DSD) over a 6-month period in Huntsville, Alabama. Comparisons indicate event rain totals for all three disdrometers that were in reasonable agreement with a reference rain gauge. In a relative sense, hourly composite DSDs revealed that the JWD was more sensitive to small drops (,1 mm), while the PD appeared to severely underestimate small drops less than 0.76mm in diameter. The JWD and 2DVD measured comparable number concentrations of midsize drops (1-3mm) and large drops (3-5 mm), while the PD tended to measure relatively higher drop concentrations at sizes larger than 2.44mm in diameter. This concentration disparity tended to occur when hourly rain rates and drop counts exceeded 2.5mm/h and 400/min, respectively. Based on interactions with the PD manufacturer, the partially inhomogeneous laser beam is considered the cause of the PD drop count overestimation. PD drop fall speeds followed the expected terminal fall speed relationship quite well, while the 2DVD occasionally measured slower drops for diameters larger than 2.4mm, coinciding with events where wind speeds were greater than 4m/s. The underestimation of small drops by the PD had a pronounced effect on the intercept and shape of parameters of gamma-fitted DSDs, while the overestimation of midsize and larger drops resulted in higher mean values for PD integral rain parameters

  15. Numerical investigation of the effect of driving voltage pulse shapes on the characteristics of low-pressure argon dielectric barrier discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslami, E., E-mail: eeslami@iust.ac.ir; Barjasteh, A.; Morshedian, N.

    2015-06-15

    In this work, we numerically compare the effect of a sinusoidal, triangular, and rectangular pulsed voltage profile on the calculated particle production, electric current, and gas voltage in a dielectric barrier discharge. The total argon gas pressure of 400 Pa, the distance between dielectrics of 5 mm, the dielectric thickness of 0.7 mm, and the temperature of T = 300 K were considered as input parameters. The different driving voltage pulse shapes (triangular, rectangular, and sinusoidal) are considered as applied voltage with a frequency of 7 kHz and an amplitude of 700 V peak to peak. It is shown thatmore » applying a rectangular voltage, as compared with a sinusoidal or triangle voltage, increases the current peak, while the peak width is decreased. Higher current density is related to high production of charged particles, which leads to the generation of some highly active species, such as Ar* (4s level), and Ar** (4p level) in the gap.« less

  16. Ion Voltage Diagnostics in the Far-Field Plume of a High-Specific Impulse Hall Thruster

    NASA Technical Reports Server (NTRS)

    Hofer, Richard R.; Haas, James M.; Gallimore, Alec D.

    2003-01-01

    The effects of the magnetic field and discharge voltage on the far-field plume of the NASA 173Mv2 laboratory-model Hall thruster were investigated. A cylindrical Langmuir probe was used to measure the plasma potential and a retarding potential analyzer was employed to measure the ion voltage distribution. The plasma potential was affected by relatively small changes in the external magnetic field, which suggested a means to control the plasma surrounding the thruster. As the discharge voltage increased, the ion voltage distribution showed that the acceleration efficiency increased and the dispersion efficiency decreased. This implied that the ionization zone was growing axially and moving closer to the anode, which could have affected thruster efficiency and lifetime due to higher wall losses. However, wall losses may have been reduced by improved focusing efficiency since the total efficiency increased and the plume divergence decreased with discharge voltage.

  17. Physical Theory of Voltage Fade in Lithium- and Manganese-Rich Transition Metal Oxides

    DOE PAGES

    Rinaldo, Steven G.; Gallagher, Kevin G.; Long, Brandon R.; ...

    2015-03-04

    Lithium- and manganese-rich (LMR) transition metal oxide cathodes are of interest for lithium-ion battery applications due to their increased energy density and decreased cost. However, the advantages in energy density and cost are offset, in part, due to the phenomena of voltage fade. Specifically, the voltage profiles (voltage as a function of capacity) of LMR cathodes transform from a high energy configuration to a lower energy configuration as they are repeatedly charged (Li removed) and discharged (Li inserted). Here, we propose a physical model of voltage fade that accounts for the emergence of a low voltage Li phase due tomore » the introduction of transition metal ion defects within a parent Li phase. The phenomenological model was re-cast in a general form and experimental LMR charge profiles were de-convoluted to extract the evolutionary behavior of various components of LMR capacitance profiles. Evolution of the voltage fade component was found to follow a universal growth curve with a maximal voltage fade capacity of ≈ 20% of the initial total capacity.« less

  18. Pulse Wave Amplitude Drops during Sleep are Reliable Surrogate Markers of Changes in Cortical Activity

    PubMed Central

    Delessert, Alexandre; Espa, Fabrice; Rossetti, Andrea; Lavigne, Gilles; Tafti, Mehdi; Heinzer, Raphael

    2010-01-01

    Background: During sleep, sudden drops in pulse wave amplitude (PWA) measured by pulse oximetry are commonly associated with simultaneous arousals and are thought to result from autonomic vasoconstriction. In the present study, we determine whether PWA drops were associated with changes in cortical activity as determined by EEG spectral analysis. Methods: A 20% decrease in PWA was chosen as a minimum for a drop. A total of 1085 PWA drops from 10 consecutive sleep recordings were analyzed. EEG spectral analysis was performed over 5 consecutive epochs of 5 seconds: 2 before, 1 during, and 2 after the PWA drop. EEG spectral analysis was performed over delta, theta, alpha, sigma, and beta frequency bands. Within each frequency band, power density was compared across the five 5-sec epochs. Presence or absence of visually scored EEG arousals were adjudicated by an investigator blinded to the PWA signal and considered associated with PWA drop if concomitant. Results: A significant increase in EEG power density in all EEG frequency bands was found during PWA drops (P < 0.001) compared to before and after drop. Even in the absence of visually scored arousals, PWA drops were associated with a significant increase in EEG power density (P < 0.001) in most frequency bands. Conclusions: Drops in PWA are associated with a significant increase in EEG power density, suggesting that these events can be used as a surrogate for changes in cortical activity during sleep. This approach may prove of value in scoring respiratory events on limited-channel (type III) portable monitors. Citation: Delessert A; Espa F; Rossetti A; Lavigne G; Tafti M; Heinzer R. Pulse wave amplitude drops during sleep are reliable surrogate markers of changes in cortical activity. SLEEP 2010;33(12):1687-1692. PMID:21120131

  19. Ion peak narrowing by applying additional AC voltage (ripple voltage) to FAIMS extractor electrode.

    PubMed

    Pervukhin, Viktor V; Sheven, Dmitriy G

    2010-01-01

    The use of a non-uniform electric field in a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer increases sensitivity but decreases resolution. The application of an additional AC voltage to the extractor electrode ("ripple" voltage, U(ripple)) can overcome this effect, which decreases the FAIMS peak width. In this approach, the diffusion ion loss remains minimal in the non-uniform electric field in the cylindrical part of the device, and all ion losses under U(ripple) occur in a short portion of their path. Application of the ripple voltage to the extractor electrode is twice as efficient as the applying of U(ripple) along the total length of the device. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  20. Numerical simulations of electric potential field for alternating current potential drop associated with surface cracks in low-alloy steel nuclear material

    NASA Astrophysics Data System (ADS)

    Yeh, Chun-Ping; Huang, Jiunn-Yuan

    2018-04-01

    Low-alloy steels used as structural materials in nuclear power plants are subjected to cyclic stresses during power plant operations. As a result, cracks may develop and propagate through the material. The alternating current potential drop technique is used to measure the lengths of cracks in metallic components. The depth of the penetration of the alternating current is assumed to be small compared to the crack length. This assumption allows the adoption of the unfolding technique to simplify the problem to a surface Laplacian field. The numerical modelling of the electric potential and current density distribution prediction model for a compact tension specimen and the unfolded crack model are presented in this paper. The goal of this work is to conduct numerical simulations to reduce deviations occurring in the crack length measurements. Numerical simulations were conducted on AISI 4340 low-alloy steel with different crack lengths to evaluate the electric potential distribution. From the simulated results, an optimised position for voltage measurements in the crack region was proposed.

  1. Complementary Barrier Infrared Detector (CBIRD) Contact Methods

    NASA Technical Reports Server (NTRS)

    Ting, David Z.; Hill, Cory J.; Gunapala, Sarath D.

    2013-01-01

    The performance of the CBIRD detector is enhanced by using new device contacting methods that have been developed. The detector structure features a narrow gap adsorber sandwiched between a pair of complementary, unipolar barriers that are, in turn, surrounded by contact layers. In this innovation, the contact adjacent to the hole barrier is doped n-type, while the contact adjacent to the electron barrier is doped p-type. The contact layers can have wider bandgaps than the adsorber layer, so long as good electrical contacts are made to them. If good electrical contacts are made to either (or both) of the barriers, then one could contact the barrier(s) directly, obviating the need for additional contact layers. Both the left and right contacts can be doped either n-type or ptype. Having an n-type contact layer next to the electron barrier creates a second p-n junction (the first being the one between the hole barrier and the adsorber) over which applied bias could drop. This reduces the voltage drop over the adsorber, thereby reducing dark current generation in the adsorber region.

  2. Inelastic deformation and damage at high temperature

    NASA Astrophysics Data System (ADS)

    Krempl, E.

    1992-06-01

    Combined experimental and theoretical investigations into the inelastic deformation and damage behavior of engineering alloys at elevated temperatures are being pursued. The analysis of previously performed strain rate change and relaxation tests on modified 9Cr-1Mo steel showed the need for inclusion of a recovery of state term in the growth laws for the state variables of the viscoplasticity theory based on overstress (VBO). Recovery of state terms were introduced and the experimental results were satisfactorily simulated. The finite deformation theory of VBO has been developed further to include a convected derivative rationale for the choice of the objective stress rate. The reversing direct current voltage drop measurements during low cycle fatigue at elevated temperature were improved. A passive filter bank and new positioning devices for the coils were installed. Tests at 650 C and lasting several days showed excessive, uncontrollable temperature changes. It was decided to drop the test temperature to 538 C which is close to the operating temperature of type 304 stainless steel. The temperature fluctuations in torsion tests were within +/- 3 C which was considered satisfactory.

  3. Drop-out and admission cancel rate among the students in a selected medical college.

    PubMed

    Wahed, F; Latif, S A; Mahamud, M M; Nessa, A; Hossain, M A; Sultana, S Z; Hossain, M B

    2011-04-01

    A record based descriptive type of study was carried out among the under-graduate students of Mymensingh Medical College from the session 1966-67 to 2006-07. The academic years were divided into four decades and admission was followed into three categories such as retained, cancellation and drop-out. Total number of the students was 5892. Among them 3848(65.30%) were male and 2044(34.69%) were female. Out of 5892 students drop-out was 282(4.78%) and admission cancel was 304(5.15%). It was also found that drop-out in male was 232(6.02%) and in female was 50(2.44%) and admission cancel in male was 266(5.87%) and in female was 78(3.81%). The difference was found statistically significant (p<0.001). It was observed that gradually the drop-out and admission cancel rate is decreasing from the very beginning to till now. It was also observed that all drop-out and admission cancellation were in first & second year students. There was no continuation of their class roll numbers in third year registration.

  4. Effect of rasanjana madhu ashchyotana in netra abhishyanda (mucopurulent conjunctivitis).

    PubMed

    Bhardwaj, Atul; Tanwar, Manoj

    2011-07-01

    To evaluate the comparative efficacy of Ayurvedic formulation a Rasanjana Madhu (RM) eye drops and Honey Rose (HR) water eye drops in Netra Abhishyanda in mucopurulent conjunctivitis, the current study is planned. Total of 35 patients attending the outpatient department of Shalakya Tantra at R. G. G. Postgraduate Ayurvedic College, Paprola, Distt. Kangra, Himachal Pradesh with characteristic features of Netra Abhishyanda were selected for the present study. Twenty patients were given trial drug, i.e., RM eye drops, while 15 patients were given HR eye drops. Random sampling technique was adopted for the present study. The duration of the treatment was 7 days with 1 week follow-up. Patients receiving the trial group demonstrated reduction of redness, burning sensation, lacrimation, photophobia, foreign body sensation, discharge, and congestion, which were statistically significant with 93% patients cured or markedly improved category. Signs and symptoms stated above were also statistically reduced with HR eye drops, probably because of well-documented hygroscopic and bacteriocidal properties of honey. Based on the study, it can be concluded that, RM eye drops are very effective in the management of Netra Abhishyanda viz. Infective conjunctivitis.

  5. Effect of Rasanjana Madhu Ashchyotana in Netra Abhishyanda (Mucopurulent Conjunctivitis)

    PubMed Central

    Bhardwaj, Atul; Tanwar, Manoj

    2011-01-01

    To evaluate the comparative efficacy of Ayurvedic formulation a Rasanjana Madhu (RM) eye drops and Honey Rose (HR) water eye drops in Netra Abhishyanda in mucopurulent conjunctivitis, the current study is planned. Total of 35 patients attending the outpatient department of Shalakya Tantra at R. G. G. Postgraduate Ayurvedic College, Paprola, Distt. Kangra, Himachal Pradesh with characteristic features of Netra Abhishyanda were selected for the present study. Twenty patients were given trial drug, i.e., RM eye drops, while 15 patients were given HR eye drops. Random sampling technique was adopted for the present study. The duration of the treatment was 7 days with 1 week follow-up. Patients receiving the trial group demonstrated reduction of redness, burning sensation, lacrimation, photophobia, foreign body sensation, discharge, and congestion, which were statistically significant with 93% patients cured or markedly improved category. Signs and symptoms stated above were also statistically reduced with HR eye drops, probably because of well-documented hygroscopic and bacteriocidal properties of honey. Based on the study, it can be concluded that, RM eye drops are very effective in the management of Netra Abhishyanda viz. Infective conjunctivitis. PMID:22529652

  6. Improved transistor-controlled and commutated brushless DC motors for electric vehicle propulsion

    NASA Technical Reports Server (NTRS)

    Demerdash, N. A.; Miller, R. H.; Nehl, T. W.; Nyamusa, T. A.

    1983-01-01

    The development, design, construction, and testing processes of two electronically (transistor) controlled and commutated permanent magnet brushless dc machine systems, for propulsion of electric vehicles are detailed. One machine system was designed and constructed using samarium cobalt for permanent magnets, which supply the rotor (field) excitation. Meanwhile, the other machine system was designed and constructed with strontium ferrite permanent magnets as the source of rotor (field) excitation. These machine systems were designed for continuous rated power output of 15 hp (11.2 kw), and a peak one minute rated power output of 35 hp (26.1 kw). Both power ratings are for a rated voltage of 115 volts dc, assuming a voltage drop in the source (battery) of about 5 volts. That is, an internal source voltage of 120 volts dc. Machine-power conditioner system computer-aided simulations were used extensively in the design process. These simulations relied heavily on the magnetic field analysis in these machines using the method of finite elements, as well as methods of modeling of the machine power conditioner system dynamic interaction. These simulation processes are detailed. Testing revealed that typical machine system efficiencies at 15 hp (11.2 kw) were about 88% and 84% for the samarium cobalt and strontium ferrite based machine systems, respectively. Both systems met the peak one minute rating of 35 hp.

  7. Consequences of converting graded to action potentials upon neural information coding and energy efficiency.

    PubMed

    Sengupta, Biswa; Laughlin, Simon Barry; Niven, Jeremy Edward

    2014-01-01

    Information is encoded in neural circuits using both graded and action potentials, converting between them within single neurons and successive processing layers. This conversion is accompanied by information loss and a drop in energy efficiency. We investigate the biophysical causes of this loss of information and efficiency by comparing spiking neuron models, containing stochastic voltage-gated Na(+) and K(+) channels, with generator potential and graded potential models lacking voltage-gated Na(+) channels. We identify three causes of information loss in the generator potential that are the by-product of action potential generation: (1) the voltage-gated Na(+) channels necessary for action potential generation increase intrinsic noise and (2) introduce non-linearities, and (3) the finite duration of the action potential creates a 'footprint' in the generator potential that obscures incoming signals. These three processes reduce information rates by ∼50% in generator potentials, to ∼3 times that of spike trains. Both generator potentials and graded potentials consume almost an order of magnitude less energy per second than spike trains. Because of the lower information rates of generator potentials they are substantially less energy efficient than graded potentials. However, both are an order of magnitude more efficient than spike trains due to the higher energy costs and low information content of spikes, emphasizing that there is a two-fold cost of converting analogue to digital; information loss and cost inflation.

  8. Consequences of Converting Graded to Action Potentials upon Neural Information Coding and Energy Efficiency

    PubMed Central

    Sengupta, Biswa; Laughlin, Simon Barry; Niven, Jeremy Edward

    2014-01-01

    Information is encoded in neural circuits using both graded and action potentials, converting between them within single neurons and successive processing layers. This conversion is accompanied by information loss and a drop in energy efficiency. We investigate the biophysical causes of this loss of information and efficiency by comparing spiking neuron models, containing stochastic voltage-gated Na+ and K+ channels, with generator potential and graded potential models lacking voltage-gated Na+ channels. We identify three causes of information loss in the generator potential that are the by-product of action potential generation: (1) the voltage-gated Na+ channels necessary for action potential generation increase intrinsic noise and (2) introduce non-linearities, and (3) the finite duration of the action potential creates a ‘footprint’ in the generator potential that obscures incoming signals. These three processes reduce information rates by ∼50% in generator potentials, to ∼3 times that of spike trains. Both generator potentials and graded potentials consume almost an order of magnitude less energy per second than spike trains. Because of the lower information rates of generator potentials they are substantially less energy efficient than graded potentials. However, both are an order of magnitude more efficient than spike trains due to the higher energy costs and low information content of spikes, emphasizing that there is a two-fold cost of converting analogue to digital; information loss and cost inflation. PMID:24465197

  9. Electric field around a dielectric elastomer actuator in proximity to the human body

    NASA Astrophysics Data System (ADS)

    McKenzie, Anita C.; Calius, Emilio P.; Anderson, Iain A.

    2008-03-01

    Dielectric elastomer actuators (DEAs) are a promising artificial muscle technology that will enable new kinds of prostheses and wearable rehabilitation devices. DEAs are driven by electric fields in the MV/m range and the dielectric elastomer itself is typically 30μm in thickness or more. Large operating voltages, in the order of several kilovolts, are then required to produce useful strains and these large voltages and the resulting electric fields could potentially pose problems when DEAs are used in close proximity to the human body. The fringing electric fields of a DEA in close association with the skin were modelled using finite element methods. The model was verified against a known analytic solution describing the electric field surrounding a capacitor in air. The agreement between the two is good, as the difference is less than 10% unless within 4.5mm of the DEA's lateral edges. As expected, it was found that for a DEA constructed with thinner dielectric layers, the fringe field strength dropped in direct proportion to the reduction in applied voltage, despite the internal field being maintained at the same level. More interestingly, modelling the electric field around stacked DEAs showed that for an even number of layers the electric field is an order of magnitude less than for an odd number of layers, due to the cancelling of opposing electric fields.

  10. Improved Signal Chains for Readout of CMOS Imagers

    NASA Technical Reports Server (NTRS)

    Pain, Bedabrata; Hancock, Bruce; Cunningham, Thomas

    2009-01-01

    An improved generic design has been devised for implementing signal chains involved in readout from complementary metal oxide/semiconductor (CMOS) image sensors and for other readout integrated circuits (ICs) that perform equivalent functions. The design applies to any such IC in which output signal charges from the pixels in a given row are transferred simultaneously into sampling capacitors at the bottoms of the columns, then voltages representing individual pixel charges are read out in sequence by sequentially turning on column-selecting field-effect transistors (FETs) in synchronism with source-follower- or operational-amplifier-based amplifier circuits. The improved design affords the best features of prior source-follower-and operational- amplifier-based designs while overcoming the major limitations of those designs. The limitations can be summarized as follows: a) For a source-follower-based signal chain, the ohmic voltage drop associated with DC bias current flowing through the column-selection FET causes unacceptable voltage offset, nonlinearity, and reduced small-signal gain. b) For an operational-amplifier-based signal chain, the required bias current and the output noise increase superlinearly with size of the pixel array because of a corresponding increase in the effective capacitance of the row bus used to couple the sampled column charges to the operational amplifier. The effect of the bus capacitance is to simultaneously slow down the readout circuit and increase noise through the Miller effect.

  11. ROSE::FTTransform - A Source-to-Source Translation Framework for Exascale Fault-Tolerance Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lidman, J; Quinlan, D; Liao, C

    2012-03-26

    Exascale computing systems will require sufficient resilience to tolerate numerous types of hardware faults while still assuring correct program execution. Such extreme-scale machines are expected to be dominated by processors driven at lower voltages (near the minimum 0.5 volts for current transistors). At these voltage levels, the rate of transient errors increases dramatically due to the sensitivity to transient and geographically localized voltage drops on parts of the processor chip. To achieve power efficiency, these processors are likely to be streamlined and minimal, and thus they cannot be expected to handle transient errors entirely in hardware. Here we present anmore » open, compiler-based framework to automate the armoring of High Performance Computing (HPC) software to protect it from these types of transient processor errors. We develop an open infrastructure to support research work in this area, and we define tools that, in the future, may provide more complete automated and/or semi-automated solutions to support software resiliency on future exascale architectures. Results demonstrate that our approach is feasible, pragmatic in how it can be separated from the software development process, and reasonably efficient (0% to 30% overhead for the Jacobi iteration on common hardware; and 20%, 40%, 26%, and 2% overhead for a randomly selected subset of benchmarks from the Livermore Loops [1]).« less

  12. Experimental study for the reproduction of sudden unintended acceleration incidents.

    PubMed

    Park, Sungji; Choi, Youngsuk; Choi, Woongchul

    2016-10-01

    A few cases of the sudden unintended acceleration have been reported over the last few years [1-11] and some of them seemed to be somewhat related to an electronic throttle control (ETC) system [11,12]. In this experimental study, efforts were made to reproduce the cases of sudden unintended acceleration possibly related to the ETC. Typically, an ETC of the engine is managed based on signals from airflow sensor, throttle position sensor and acceleration pedal sensor. With this typical sensor configuration in mind, these sensor signals were checked for noise levels. However, none of them showed any clear relationship with the sudden unintended acceleration mainly due to the robustness of the ETC logic software. As an alternative approach, supply voltage to an engine control unit (ECU) was tempered intentionally to observe any clues for the incidents. The observed results with the supply voltage drop and fluctuation tests were rather astonishing. The throttle valve position went all the way up to 100% for around one second when the battery voltage plunged down to 7V periodically despite that the acceleration pedal position was kept steady. As an effort to confirm the case, multiple tries were made systematically on a chassis dynamometer as well as on the test road. In this paper, detailed procedures and findings are reported accordingly. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Elucidating the Irreversible Mechanism and Voltage Hysteresis in Conversion Reaction for High-Energy Sodium-Metal Sulfide Batteries

    DOE PAGES

    Wang, Jiajun; Wang, Liguang; Eng, Christopher; ...

    2017-03-03

    We present that irreversible electrochemical behavior and large voltage hysteresis are commonly observed in battery materials, in particular for materials reacting through conversion reaction, resulting in undesirable round-trip energy loss and low coulombic efficiency. Seeking solutions to these challenges relies on the understanding of the underlying mechanism and physical origins. Here, this study combines in operando 2D transmission X-ray microscopy with X-ray absorption near edge structure, 3D tomography, and galvanostatic intermittent titration techniques to uncover the conversion reaction in sodium–metal sulfide batteries, a promising high-energy battery system. This study shows a high irreversible electrochemistry process predominately occurs at first cycle,more » which can be largely linked to Na ion trapping during the first desodiation process and large interfacial ion mobility resistance. Subsequently, phase transformation evolution and electrochemical reaction show good reversibility at multiple discharge/charge cycles due to materials' microstructural change and equilibrium. The origin of large hysteresis between discharge and charge is investigated and it can be attributed to multiple factors including ion mobility resistance at the two-phase interface, intrinsic slow sodium ion diffusion kinetics, and irreversibility as well as ohmic voltage drop and overpotential. In conclusion, this study expects that such understandings will help pave the way for engineering design and optimization of materials microstructure for future-generation batteries.« less

  14. Design, fabrication, and operation of dished accelerator grids on a 30-cm ion thruster

    NASA Technical Reports Server (NTRS)

    Rawlin, V. K.; Banks, B. A.; Byers, D. C.

    1972-01-01

    Several closely-space dished accelerator grid systems were fabricated and tested on a 30-cm diameter mercury bombardment thruster and they appear to be a solution to the stringent requirements imposed by the near-term, high-thrust, low specific impulse electric propulsion missions. The grids were simultaneously hydroformed and then simultaneously stress relieved. The ion extraction capability and discharge chamber performance were studied as the total accelerating voltage, the ratio of net-to-total voltage, grid spacing, and dish direction were varied.

  15. The relationship between Q gamma and Ca release from the sarcoplasmic reticulum in skeletal muscle

    PubMed Central

    1991-01-01

    Asymmetric membrane currents and fluxes of Ca2+ release were determined in skeletal muscle fibers voltage clamped in a Vaseline-gap chamber. The conditioning pulse protocol 1 for suppressing Ca2+ release and the "hump" component of charge movement current (I gamma), described in the first paper of this series, was applied at different test pulse voltages. The amplitude of the current suppressed during the ON transient reached a maximum at slightly suprathreshold test voltages (- 50 to -40 mV) and decayed at higher voltages. The component of charge movement current suppressed by 20 microM tetracaine also went through a maximum at low pulse voltages. This anomalous voltage dependence is thus a property of I gamma, defined by either the conditioning protocol or the tetracaine effect. A negative (inward-going) phase was often observed in the asymmetric current during the ON of depolarizing pulses. This inward phase was shown to be an intramembranous charge movement based on (a) its presence in the records of total membrane current, (b) its voltage dependence, with a maximum at slightly suprathreshold voltages, (c) its association with a "hump" in the asymmetric current, (d) its inhibition by interventions that reduce the "hump", (e) equality of ON and OFF areas in the records of asymmetric current presenting this inward phase, and (f) its kinetic relationship with the time derivative of Ca release flux. The nonmonotonic voltage dependence of the amplitude of the hump and the possibility of an inward phase of intramembranous charge movement are used as the main criteria in the quantitative testing of a specific model. According to this model, released Ca2+ binds to negatively charged sites on the myoplasmic face of the voltage sensor and increases the local transmembrane potential, thus driving additional charge movement (the hump). This model successfully predicts the anomalous voltage dependence and all the kinetic properties of I gamma described in the previous papers. It also accounts for the inward phase in total asymmetric current and in the current suppressed by protocol 1. According to this model, I gamma accompanies activating transitions at the same set of voltage sensors as I beta. Therefore it should open additional release channels, which in turn should cause more I gamma, providing a positive feedback mechanism in the regulation of calcium release. PMID:1650812

  16. Electrowetting for Digital Microfluidics

    NASA Astrophysics Data System (ADS)

    Hunt, Tom; Adamson, Kristi; Issadore, David; Westervelt, Robert

    2006-03-01

    Droplet based chemistry promises to greatly impact biomedical research, providing new avenues for high throughput, low volume assays such as drug screening. Electrowetting on Dielectric (EWOD) is an excellent technique for manipulating microscopic drops of liquid. EWOD uses buried electrodes to locally change the surface energy between a droplet and a substrate. We present microfabricated devices for moving droplets with EWOD. One example of such a device consists of a series of 16 interdigitated electrodes, decreasing in size from 1mm to 20 microns. Each electrode is addressable by an independent, computer controlled, high voltage supply. This work made possible by a gift from Phillip Morris and the NSEC NSF grant PHY-0117795.

  17. Digital lock-in amplifier based on soundcard interface for physics laboratory

    NASA Astrophysics Data System (ADS)

    Sinlapanuntakul, J.; Kijamnajsuk, P.; Jetjamnong, C.; Chotikaprakhan, S.

    2017-09-01

    The purpose of this paper is to develop a digital lock-in amplifier based on soundcard interface for undergraduate physics laboratory. Both series and parallel RLC circuit laboratory are tested because of its well-known, easy to understand and simple confirm. The sinusoidal signal at the frequency of 10 Hz - 15 kHz is generated to the circuits. The amplitude and phase of the voltage drop across the resistor, R are measured in 10 step decade. The signals from soundcard interface and lock-in amplifier are compared. The results give a good correlation. It indicates that the design digital lock-in amplifier is promising for undergraduate physic laboratory.

  18. Fault-tolerant power distribution system

    NASA Technical Reports Server (NTRS)

    Volp, Jeffrey A. (Inventor)

    1987-01-01

    A fault-tolerant power distribution system which includes a plurality of power sources and a plurality of nodes responsive thereto for supplying power to one or more loads associated with each node. Each node includes a plurality of switching circuits, each of which preferably uses a power field effect transistor which provides a diode operation when power is first applied to the nodes and which thereafter provides bi-directional current flow through the switching circuit in a manner such that a low voltage drop is produced in each direction. Each switching circuit includes circuitry for disabling the power field effect transistor when the current in the switching circuit exceeds a preselected value.

  19. Programmable Logic Application Notes

    NASA Technical Reports Server (NTRS)

    Katz, Richard

    1999-01-01

    This column will be provided each quarter as a source for reliability, radiation results, NASA capabilities, and other information on programmable logic devices and related applications. This quarter the focus is on some experimental data on low voltage drop out regulators to support mixed 5 and 3.3 volt systems. A discussion of the Small Explorer WIRE spacecraft will also be given. Lastly, we show take a first look at robust state machines in Hardware Description Languages (VHDL) and their use in critical systems. If you have information that you would like to submit or an area you would like discussed or researched, please give me a call or e-mail.

  20. Pulsed Discharge in Aerosol for Waste Water Clean-up.

    NASA Astrophysics Data System (ADS)

    Bystritskii, V. M.; Gonzales, A.; Olson, T.; Puchkarev, V.; Rosocha, L.; Wessel, F.; Yankelevich, Y.

    1996-11-01

    Aerosol (drop diameter of 10-100 μm) is injected into a discharge reactor with a repetitively pulsed voltage of 40--60 kV, 50--150 ns, 10^2--10^3 Hz. The relatively large water dielectric constant and high degree of atomization result in efficient degradation of organic molecules. Results on the characterization of operational parameters of the device and on degradation performance for a variety of organic pollutants (paranitrophenol, di-Chlorophenol, per-chloro-ethylene) are discussed. Work was supported by the Los Alamos National Laboratories 96 LACOR Program. ^AUniversity of Southern California, Los Angeles, CA 94007 ^BLos Alamos National Laboratory, Los Alamos, NM 87545

  1. Laboratory experiments on plasma contactors

    NASA Technical Reports Server (NTRS)

    Wilbur, Paul J.; Williams, John D.

    1990-01-01

    Experimental results describing the operation of hollow cathode plasma contactors collecting and emitting electrons from and to an ambient plasma at current levels of the order of one ampere are presented. The voltage drops induced between a contactor and an ambient plasma are shown to be a few tens of volts at such current levels. The development of a double sheath and the production of substantial numbers of ions by electrons streaming across it are associated with the electron collection process. The development of a complex potential structure including a high potential hill just downstream of the cathode orifice is shown to characterize typical contactor emitting electrons.

  2. Performance Theory of Diagonal Conducting Wall MHD Accelerators

    NASA Technical Reports Server (NTRS)

    Litchford, R. J.

    2003-01-01

    The theoretical performance of diagonal conducting wall crossed field accelerators is examined on the basis of an infinite segmentation assumption using a cross-plane averaged generalized Ohm's law for a partially ionized gas, including ion slip. The desired accelerator performance relationships are derived from the cross-plane averaged Ohm's law by imposing appropriate configuration and loading constraints. A current dependent effective voltage drop model is also incorporated to account for cold-wall boundary layer effects including gasdynamic variations, discharge constriction, and electrode falls. Definition of dimensionless electric fields and current densities lead to the construction of graphical performance diagrams, which further illuminate the rudimentary behavior of crossed field accelerator operation.

  3. Power transmission cable development for the Space Station Freedom electrical power system

    NASA Technical Reports Server (NTRS)

    Schmitz, Gregory V.; Biess, John J.

    1989-01-01

    Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

  4. Simultaneous measurement of temperature and strain using four connecting wires

    NASA Technical Reports Server (NTRS)

    Parker, Allen R., Jr.

    1993-01-01

    This paper describes a new signal-conditioning technique for measuring strain and temperature which uses fewer connecting wires than conventional techniques. Simultaneous measurement of temperature and strain has been achieved by using thermocouple wire to connect strain gages to signal conditioning. This signal conditioning uses a new method for demultiplexing sampled analog signals and the Anderson current loop circuit. Theory is presented along with data to confirm that strain gage resistance change is sensed without appreciable error because of thermoelectric effects. Furthermore, temperature is sensed without appreciable error because of voltage drops caused by strain gage excitation current flowing through the gage resistance.

  5. Carbon supercapacitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delnick, F.M.

    1993-11-01

    Carbon supercapacitors are represented as distributed RC networks with transmission line equivalent circuits. At low charge/discharge rates and low frequencies these networks approximate a simple series R{sub ESR}C circuit. The energy efficiency of the supercapacitor is limited by the voltage drop across the ESR. The pore structure of the carbon electrode defines the electrochemically active surface area which in turn establishes the volume specific capacitance of the carbon material. To date, the highest volume specific capacitance reported for a supercapacitor electrode is 220F/cm{sup 3} in aqueous H{sub 2}SO{sub 4} (10) and {approximately}60 F/cm{sup 3} in nonaqueous electrolyte (8).

  6. A new inverter topology using GTO commutation. [Gate Turn Off thyristor

    NASA Technical Reports Server (NTRS)

    Rippel, W. E.

    1983-01-01

    A new N-phase, forced commutated bridge inverter topology has been developed wherein a single Gate Turn Off Thyristor (GTO) is used to commutate each of 2N main Thyristors (SCRs). Since, for most applications, the primary loss mechanism is the SCR forward drop, very high efficiencies are possible. Compared with conventional pure SCR and pure GTO inverters, cost per kW is lower - in the former case due to the large cost differential between GTOs and SCRs. Other advantages of the new inverter include high power density, low switching losses and stresses, modulation flexibility and amenability to high voltage and high frequency operation.

  7. A Grounded Theory Study of the Re-Entry Process of Teen Parents' Return to School after Dropping Out

    ERIC Educational Resources Information Center

    Melton, Brenda L.

    2013-01-01

    Without the rich stories of the experiences of teen parents who drop out of school and then re-enter, we do not have a total picture of the dropout phenomenon and how best to address the issues for this marginalized group. Using the research strategies of Charmaz' social constructivist grounded theory, Melton has gathered detailed stories about…

  8. An iterative model for the steady state current distribution in oxide-confined vertical-cavity surface-emitting lasers (VCSELs)

    NASA Astrophysics Data System (ADS)

    Chuang, Hsueh-Hua

    The purpose of this dissertation is to develop an iterative model for the analysis of the current distribution in vertical-cavity surface-emitting lasers (VCSELs) using a circuit network modeling approach. This iterative model divides the VCSEL structure into numerous annular elements and uses a circuit network consisting of resistors and diodes. The measured sheet resistance of the p-distributed Bragg reflector (DBR), the measured sheet resistance of the layers under the oxide layer, and two empirical adjustable parameters are used as inputs to the iterative model to determine the resistance of each resistor. The two empirical values are related to the anisotropy of the resistivity of the p-DBR structure. The spontaneous current, stimulated current, and surface recombination current are accounted for by the diodes. The lateral carrier transport in the quantum well region is analyzed using drift and diffusion currents. The optical gain is calculated as a function of wavelength and carrier density from fundamental principles. The predicted threshold current densities for these VCSELs match the experimentally measured current densities over the wavelength range of 0.83 mum to 0.86 mum with an error of less than 5%. This model includes the effects of the resistance of the p-DBR mirrors, the oxide current-confining layer and spatial hole burning. Our model shows that higher sheet resistance under the oxide layer reduces the threshold current, but also reduces the current range over which single transverse mode operation occurs. The spatial hole burning profile depends on the lateral drift and diffusion of carriers in the quantum wells but is dominated by the voltage drop across the p-DBR region. To my knowledge, for the first time, the drift current and the diffusion current are treated separately. Previous work uses an ambipolar approach, which underestimates the total charge transferred in the quantum well region, especially under the oxide region. However, the total result of the drift current and the diffusion current is less significant than the Ohmic current, especially in the cavity region. This simple iterative model is applied to commercially available oxide-confined VCSELs. The simulation results show excellent agreement with experimentally measured voltage-current curves (within 3.7% for a 10 mum and within 4% for a 5 mum diameter VCSEL) and light-current curves (within 2% for a 10 mum and within 9% for a 5 mum diameter VCSEL) curves and provides insight into the detailed distributions of current and voltage within a VCSEL. This difference between the theoretically calculated results and the measured results is less than the variation shown in the data sheets for production VCSELs.

  9. Intra-articular versus intravenous tranexamic acid application in total knee arthroplasty: a meta-analysis of randomized controlled trials.

    PubMed

    Mi, Bobin; Liu, Guohui; Zhou, Wu; Lv, Huijuan; Liu, Yi; Zha, Kun; Wu, Qipeng; Liu, Jing

    2017-07-01

    The purpose of this meta-analysis was to compare the blood loss and complications of intra-articular (IA) with intravenous (IV) tranexamic acid (TXA) for total knee arthroplasty (TKA). A comprehensive search of studies was conducted to identify related articles in Pubmed, Embase, Cochrane central Register of Controlled Trials, springerLink, OVID and the Research published from January 1980 to September 2016. All studies that compared IA TXA with IV TXA application on TKA were included. Main outcomes of the two methods were collected and analyzed by using Review Manager 5.3. There were 16 randomized controlled trials with 1308 cases met the criteria. Compared with IV TXA, IA TXA had similar blood volume of drainage, hidden blood loss, transfusion rate and complications (P > 0.05). IA TXA had lower total blood loss than IV TXA, and there was significant difference (P < 0.05). Subgroup analysis of total blood loss based on times of IV TXA administration showed that repeat dose of IV TXA had a higher total blood loss and postoperative hemoglobin drop (P < 0.05) than IA TXA. However, single dose of IV TXA had a similar efficacy on total blood loss and postoperative hemoglobin drop (P > 0.05) when compared with IA TXA. Both IA TXA and single dose of IV TXA are effective in reducing total blood loss and postoperative hemoglobin drop without increasing complications of DVT or PE. The current meta-analysis suggests that 1.5 g TXA by IA administration or 1 g TXA by IV administration 10 min before tourniquet deflation is effective and safe in patients undergoing TKA.

  10. Novel non-equilibrium modelling of a DC electric arc in argon

    NASA Astrophysics Data System (ADS)

    Baeva, M.; Benilov, M. S.; Almeida, N. A.; Uhrlandt, D.

    2016-06-01

    A novel non-equilibrium model has been developed to describe the interplay of heat and mass transfer and electric and magnetic fields in a DC electric arc. A complete diffusion treatment of particle fluxes, a generalized form of Ohm’s law, and numerical matching of the arc plasma with the space-charge sheaths adjacent to the electrodes are applied to analyze in detail the plasma parameters and the phenomena occurring in the plasma column and the near-electrode regions of a DC arc generated in atmospheric pressure argon for current levels from 20 A up to 200 A. Results comprising electric field and potential, current density, heating of the electrodes, and effects of thermal and chemical non-equilibrium are presented and discussed. The current-voltage characteristic obtained is in fair agreement with known experimental data. It indicates a minimum for arc current of about 80 A. For all current levels, a field reversal in front of the anode accompanied by a voltage drop of (0.7-2.6) V is observed. Another field reversal is observed near the cathode for arc currents below 80 A.

  11. Charge storage in β-FeSi2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Theis, Jens; Bywalez, Robert; Küpper, Sebastian; Lorke, Axel; Wiggers, Hartmut

    2015-02-01

    We report on the observation of a surprisingly high specific capacitance of β-FeSi2 nanoparticle layers. Lateral, interdigitated capacitor structures were fabricated on thermally grown silicon dioxide and covered with β-FeSi2 particles by drop or spin casting. The β-FeSi2-nanoparticles, with crystallite sizes in the range of 10-30 nm, were fabricated by gas phase synthesis in a hot wall reactor. Compared to the bare electrodes, the nanoparticle-coated samples exhibit a 3-4 orders of magnitude increased capacitance. Time-resolved current voltage measurements show that for short times (seconds to minutes), the material is capable of storing up to 1 As/g at voltages of around 1 V. The devices are robust and exhibit long-term stability under ambient conditions. The specific capacitance is highest for a saturated relative humidity, while for a relative humidity below 40% the capacitance is almost indistinguishable from a nanoparticle-free reference sample. The devices work without the need of a fluid phase, the charge storing material is abundant and cost effective, and the sample design is easy to fabricate.

  12. The temperature dependence of the characteristics of crystalline-silicon-based heterojunction solar cells

    NASA Astrophysics Data System (ADS)

    Sachenko, A. V.; Kryuchenko, Yu. V.; Kostylyov, V. P.; Korkishko, R. M.; Sokolovskyi, I. O.; Abramov, A. S.; Abolmasov, S. N.; Andronikov, D. A.; Bobyl', A. V.; Panaiotti, I. E.; Terukov, E. I.; Titov, A. S.; Shvarts, M. Z.

    2016-03-01

    Temperature dependences of the photovoltaic characteristics of ( p)a-Si/( i)a-Si:H/( n)c-Si singlecrystalline- silicon based heterojunction-with-intrinsic-thin-layer (HIT) solar cells have been measured in a temperature range of 80-420 K. The open-circuit voltage ( V OC), fill factor ( FF) of the current-voltage ( I-U) characteristic, and maximum output power ( P max) reach limiting values in the interval of 200-250 K on the background of monotonic growth in the short-circuit current ( I SC) in a temperature range of 80-400 K. At temperatures below this interval, the V OC, FF, and P max values exhibit a decrease. It is theoretically justified that a decrease in the photovoltaic energy conversion characteristics of solar cells observed on heating from 250 to 400 K is related to exponential growth in the intrinsic conductivity. At temperatures below 200 K, the I-U curve shape exhibits a change that is accompanied by a drop in V OC. Possible factors that account for the decrease in V OC, FF, and P max are considered.

  13. A computation study on the interplay between surface morphology and electrochemical performance of patterned thin film electrodes for Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Gur, Sourav; Frantziskonis, George N.; Aifantis, Katerina E.

    2017-08-01

    Recent experiments illustrate that the morphology of the electrode surface impacts the voltage - capacity curves and long term cycling performance of Li-ion batteries. The present study systematically explores the role of the electrode surface morphology and uncertainties in the reactions that occur during electrochemical cycling, by performing kinetic Monte Carlo (kMC) simulations using the lattice Boltzmann method (LBM). This allows encoding of the inherent stochasticity at discrete microscale reaction events over the deterministic mean field reaction dynamics that occur in Li-ion cells. The electrodes are taken to be dense thin films whose surfaces are patterned with conical, trapezoidal, dome-shaped, or pillar-shaped structures. It is shown that the inherent perturbations in the reactions together with the characteristics of the electrode surface configuration can significantly improve battery performance, mainly because patterned surfaces, as opposed to flat surfaces, result in a smaller voltage drop. The most efficient pattern was the trapezoidal, which is consistent with experimental evidence on Si patterned electrodes.

  14. Heterojunction photodetector based on graphene oxide sandwiched between ITO and p-Si

    NASA Astrophysics Data System (ADS)

    Ahmad, H.; Tajdidzadeh, M.; Thandavan, T. M. K.

    2018-02-01

    The drop casting method is utilized on indium tin oxide (ITO)-coated glass in order to prepare a sandwiched ITO/graphene oxide (ITO/GO) with silicon dioxide/p-type silicon (SiO2/p-Si) heterojunction photodetector. The partially sandwiched GO layer with SiO2/p-Si substrate exhibits dual characteristics as it showed good sensitivity towards the illumination of infrared (IR) laser at wavelength of 974 nm. Excellent photoconduction is also observed for current-voltage (I-V) characteristics at various laser powers. An external quantum efficiency greater than 1 for a direct current bias voltage of 0 and 3 V reveals significant photoresponsivity of the photodetector at various laser frequency modulation at 1, 5 and 9 Hz. The rise times are found to be 75, 72 and 70 μs for 1, 5 and 9 Hz while high fall times 455, 448 and 426 are measured for the respective frequency modulation. The fabricated ITO/GO-SiO2/p-Si sandwiched heterojunction photodetector can be considered as a good candidate for applications in the IR regions that do not require a high-speed response.

  15. Survivability of Autonomous Microgrid during Overload Events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Wei; Lasseter, Robert H.; Khalsa, Amrit S.

    Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sourcesmore » in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.« less

  16. Survivability of Autonomous Microgrid during Overload Events

    DOE PAGES

    Du, Wei; Lasseter, Robert H.; Khalsa, Amrit S.

    2018-04-23

    Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sourcesmore » in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.« less

  17. Fabrication of resistively-coupled single-electron device using an array of gold nanoparticles

    NASA Astrophysics Data System (ADS)

    Huong, Tran Thi Thu; Matsumoto, Kazuhiko; Moriya, Masataka; Shimada, Hiroshi; Kimura, Yasuo; Hirano-Iwata, Ayumi; Mizugaki, Yoshinao

    2017-08-01

    We demonstrated one type of single-electron device that exhibited electrical characteristics similar to those of resistively-coupled SE transistor (R-SET) at 77 K and room temperature (287 K). Three Au electrodes on an oxidized Si chip served as drain, source, and gate electrodes were formed using electron-beam lithography and evaporation techniques. A narrow (70-nm-wide) gate electrode was patterned using thermal evaporation, whereas wide (800-nm-wide) drain and source electrodes were made using shadow evaporation. Subsequently, aqueous solution of citric acid and 15-nm-diameter gold nanoparticles (Au NPs) and toluene solution of 3-nm-diameter Au NPs chemisorbed via decanethiol were dropped on the chip to make the connections between the electrodes. Current-voltage characteristics between the drain and source electrodes exhibited Coulomb blockade (CB) at both 77 and 287 K. Dependence of the CB region on the gate voltage was similar to that of an R-SET. Simulation results of the model based on the scanning electron microscopy image of the device could reproduce the characteristics like the R-SET.

  18. Modeling of hysteretic Schottky diode-like conduction in Pt/BiFeO3/SrRuO3 switches

    NASA Astrophysics Data System (ADS)

    Miranda, E.; Jiménez, D.; Tsurumaki-Fukuchi, A.; Blasco, J.; Yamada, H.; Suñé, J.; Sawa, A.

    2014-08-01

    The hysteresis current-voltage (I-V) loops in Pt/BiFeO3/SrRuO3 structures are simulated using a Schottky diode-like conduction model with sigmoidally varying parameters, including series resistance correction and barrier lowering. The evolution of the system is represented by a vector in a 3D parameter space describing a closed trajectory with stationary states. It is shown that the hysteretic behavior is not only the result of a Schottky barrier height (SBH) variation arising from the BiFeO3 polarization reversal but also a consequence of the potential drop distribution across the device. The SBH modulation is found to be remarkably lower (<0.07 eV) than previously reported (>0.5 eV). It is also shown that the p-type semiconducting nature of BiFeO3 can explain the large ideality factors (>6) required to simulate the I-V curves as well as the highly asymmetric set and reset voltages (4.7 V and -1.9 V) exhibited by our devices.

  19. Charge transport in doped zigzag phosphorene nanoribbons

    NASA Astrophysics Data System (ADS)

    Nourbakhsh, Zahra; Asgari, Reza

    2018-06-01

    The effects of lattice distortion and chemical disorder on charge transport properties of two-terminal zigzag phosphorene nanoribbons (zPNRs), which shows resonant tunneling behavior under an electrical applied bias, are studied. Our comprehensive study is based on ab initio quantum transport calculations on the basis of the Landauer theory. We use nitrogen and silicon substitutional dopant atoms, and employ different physical quantities such as the I -V curve, voltage drop behavior, transmission spectrum, transmission pathway, and atomic current to explore the transport mechanism of zPNR devices under a bias voltage. The calculated transmission pathways show the transition from a ballistic transport regime to a diffusive and in some particular cases to localized transport regimes. Current flowing via the chemical bonds and hopping are monitored; however, the conductance originates mainly from the charge traveling through the chemical bonds in the vicinity of the zigzag edges. Our results show that in the doped systems, the device conductance decreases and the negative differential resistance characteristic becomes weak or is eliminated. Besides, the conductance in a pure zPNR system is almost independent of the ribbon width.

  20. The effect of cathode felt geometries on electrochemical characteristics of sodium sulfur (NaS) cells: Planar vs. tubular

    NASA Astrophysics Data System (ADS)

    Kim, Goun; Park, Yoon-Cheol; Lee, Younki; Cho, Namung; Kim, Chang-Soo; Jung, Keeyoung

    2016-09-01

    Two sodium sulfur (NaS) cells, one with a planar design and the other with a tubular design, were subject to discharge-charge cycles in order to investigate the effect of cathode felt geometries on electrochemical characteristics of NaS cells. Their discharge-charge behaviors over 200 cycles were evaluated at the operation temperature of 350 °C with the current densities of 100 mA cm-2 for discharge and 80 mA cm-2 for charge. The results showed that the deviation from theoretical open circuit voltage changes of a planar cell was smaller than those of a tubular cell resulting in potential specific power loss reduction during operation. In order to understand the effect, a three dimensional statistically representative matrix for a cathode felt has been generated using experimentally measured data. It turns out that the area specific fiber number density in the outer side area of a tubular cathode felt is smaller than that of a planar felt resulting in occurrence of larger voltage drops via retarded convection of cathode melts during cell operation.

  1. FET commutated current-FED inverter

    NASA Technical Reports Server (NTRS)

    Rippel, Wally E. (Inventor); Edwards, Dean B. (Inventor)

    1983-01-01

    A shunt switch comprised of a field-effect transistor (Q.sub.1) is employed to commutate a current-fed inverter (10) using thyristors (SCR1, SCR2) or bijunction transistors (Q.sub.2, Q.sub.3) in a full bridge (1, 2, 3, 4) or half bridge (5, 6) and transformer (T.sub.1) configuration. In the case of thyristors, a tapped inverter (12) is employed to couple the inverter to a dc source to back bias the thyristors during commutation. Alternatively, a commutation power supply (20) may be employed for that purpse. Diodes (D.sub.1, D.sub.2) in series with some voltage dropping element (resistor R.sub.12 or resistors R.sub.1, R.sub.2 or Zener diodes D.sub.4, D.sub.5) are connected in parallel with the thyristors in the half bridge and transformer configuration to assure sharing the back bias voltage. A clamp circuit comprised of a winding (18) negatively coupled to the inductor and a diode (D.sub.3) return stored energy from the inductor to the power supply for efficient operation with buck or boost mode.

  2. Estimating the irreversible pressure drop across a stenosis by quantifying turbulence production using 4D Flow MRI

    PubMed Central

    Ha, Hojin; Lantz, Jonas; Ziegler, Magnus; Casas, Belen; Karlsson, Matts; Dyverfeldt, Petter; Ebbers, Tino

    2017-01-01

    The pressure drop across a stenotic vessel is an important parameter in medicine, providing a commonly used and intuitive metric for evaluating the severity of the stenosis. However, non-invasive estimation of the pressure drop under pathological conditions has remained difficult. This study demonstrates a novel method to quantify the irreversible pressure drop across a stenosis using 4D Flow MRI by calculating the total turbulence production of the flow. Simulation MRI acquisitions showed that the energy lost to turbulence production can be accurately quantified with 4D Flow MRI within a range of practical spatial resolutions (1–3 mm; regression slope = 0.91, R2 = 0.96). The quantification of the turbulence production was not substantially influenced by the signal-to-noise ratio (SNR), resulting in less than 2% mean bias at SNR > 10. Pressure drop estimation based on turbulence production robustly predicted the irreversible pressure drop, regardless of the stenosis severity and post-stenosis dilatation (regression slope = 0.956, R2 = 0.96). In vitro validation of the technique in a 75% stenosis channel confirmed that pressure drop prediction based on the turbulence production agreed with the measured pressure drop (regression slope = 1.15, R2 = 0.999, Bland-Altman agreement = 0.75 ± 3.93 mmHg). PMID:28425452

  3. Investigation and optimization of low-frequency noise performance in readout electronics of dc superconducting quantum interference device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Jing; Peter Grünberg Institute; Zhang, Yi

    2014-05-15

    We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mAmore » to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.« less

  4. Investigation and optimization of low-frequency noise performance in readout electronics of dc superconducting quantum interference device

    NASA Astrophysics Data System (ADS)

    Zhao, Jing; Zhang, Yi; Lee, Yong-Ho; Krause, Hans-Joachim

    2014-05-01

    We investigated and optimized the low-frequency noise characteristics of a preamplifier used for readout of direct current superconducting quantum interference devices (SQUIDs). When the SQUID output was detected directly using a room-temperature low-voltage-noise preamplifier, the low-frequency noise of a SQUID system was found to be dominated by the input current noise of the preamplifiers in case of a large dynamic resistance of the SQUID. To reduce the current noise of the preamplifier in the low-frequency range, we investigated the dependence of total preamplifier noise on the collector current and source resistance. When the collector current was decreased from 8.4 mA to 3 mA in the preamplifier made of 3 parallel SSM2220 transistor pairs, the low-frequency total voltage noise of the preamplifier (at 0.1 Hz) decreased by about 3 times for a source resistance of 30 Ω whereas the white noise level remained nearly unchanged. Since the relative contribution of preamplifier's input voltage and current noise is different depending on the dynamic resistance or flux-to-voltage transfer of the SQUID, the results showed that the total noise of a SQUID system at low-frequency range can be improved significantly by optimizing the preamplifier circuit parameters, mainly the collector current in case of low-noise bipolar transistor pairs.

  5. A triple hybrid micropower generator with simultaneous multi-mode energy harvesting

    NASA Astrophysics Data System (ADS)

    Uluşan, H.; Chamanian, S.; Pathirana, W. P. M. R.; Zorlu, Ö.; Muhtaroğlu, A.; Külah, H.

    2018-01-01

    This study presents a triple hybrid energy harvesting system that combines harvested power from thermoelectric (TE), vibration-based electromagnetic (EM) and piezoelectric (PZT) harvesters into a single DC supply. A power management circuit is designed and implemented in 180 nm standard CMOS technology based on the distinct requirements of each harvester, and is terminated with a Schottky diode to avoid reverse current flow. The system topology hence supports simultaneous power generation and delivery from low and high frequency vibrations as well as temperature differences in the environment. The ultra-low DC voltage harvested from TE generator is boosted with a cross-coupled charge-pump driven by an LC oscillator with fully-integrated center-tapped differential inductors. The EM harvester output was rectified with a self-powered and low drop-out AC/DC doubler circuit. The PZT interface electronics benefits from peak-to-peak cycle of the harvested voltage through a negative voltage converter followed by synchronous power extraction and DC-to-DC conversion through internal switches, and an external inductor. The hybrid system was tested with a wearable in-house EM energy harvester placed wrist of a jogger, a commercial low volume PZT harvester, and DC supply as the TE generator output. The system generates more than 1.2 V output for load resistances higher than 50 kΩ, which corresponds to 24 μW to power wearable sensors. Simultaneous multi-mode operation achieves higher voltage and power compared to stand-alone harvesting circuits, and generates up to 110 μW of output power. This is the first hybrid harvester circuit that simultaneously extracts energy from three independent sources, and delivers a single DC output.

  6. Prototype Software for Future Spaceflight Tested at Mars Desert Research Station

    NASA Technical Reports Server (NTRS)

    Clancey, William J.; Sierhuis, Maaretn; Alena, Rick; Dowding, John; Garry, Brent; Scott, Mike; Tompkins, Paul; vanHoof, Ron; Verma, Vandi

    2006-01-01

    NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since <#> {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I | everyone} when{ ever} the generator goes offline. 7. Tell {me | | everyone} when the hab{itat} {amps | volts | voltage} {exceeds | drops brelow} <#>. 8. {Send | Take | Record} {a} voice note {(for | to} } {at

  7. Limited Relationship of Voltage Criteria for Electrocardiogram Left Ventricular Hypertrophy to Cardiovascular Mortality.

    PubMed

    Ha, Le Dung; Elbadawi, Ayman; Froelicher, Victor F

    2018-01-01

    Numerous methods have been proposed for diagnosing left ventricular hypertrophy using the electrocardiogram. They have limited sensitivity for recognizing pathological hypertrophy, at least in part due to their inability to distinguish pathological from physiological hypertrophy. Our objective is to compare the major electrocardiogram-left ventricular hypertrophy criteria using cardiovascular mortality as a surrogate for pathological hypertrophy. This study was a retrospective analysis of 16,253 veterans < 56 years of age seen at a large Veterans Affairs Medical Center from 1987 to 1999 and followed a median of 17.8 years for cardiovascular mortality. Receiver operating characteristics and Cox hazard survival techniques were applied. Of the 16,253 veterans included in our target population, the mean age was 43 years, 8.6% were female, 33.5% met criteria for electrocardiogram-left ventricular hypertrophy, and there were 744 cardiovascular deaths (annual cardiovascular mortality 0.25%). Receiver operating characteristic analysis demonstrated that the greatest area under the curve (AUC) for classification of cardiovascular death was obtained using the Romhilt-Estes score (0.63; 95% confidence interval, 0.61-0.65). Most of the voltage-only criteria had nondiagnostic area under the curves, with the Cornell being the best at 0.59 (95% confidence interval, 0.57-0.62). When the components of the Romhilt-Estes score were examined using step-wise Wald analysis, the voltage criteria dropped from the model. The Romhilt-Estes score ≥ 4, the Cornell, and the Peguero had the highest association with cardiovascular mortality (adjusted hazard ratios 2.2, 2.0, and 2.1, consecutively). None of the electrocardiogram leads with voltage criteria exhibited sufficient classification power for clinical use. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Low-Actuation Voltage MEMS Digital-to-Analog Converter with Parylene Spring Structures.

    PubMed

    Ma, Cheng-Wen; Lee, Fu-Wei; Liao, Hsin-Hung; Kuo, Wen-Cheng; Yang, Yao-Joe

    2015-08-28

    We propose an electrostatically-actuated microelectromechanical digital-to-analog converter (M-DAC) device with low actuation voltage. The spring structures of the silicon-based M-DAC device were monolithically fabricated using parylene-C. Because the Young's modulus of parylene-C is considerably lower than that of silicon, the electrostatic microactuators in the proposed device require much lower actuation voltages. The actuation voltage of the proposed M-DAC device is approximately 6 V, which is less than one half of the actuation voltages of a previously reported M-DAC equipped with electrostatic microactuators. The measured total displacement of the proposed three-bit M-DAC is nearly 504 nm, and the motion step is approximately 72 nm. Furthermore, we demonstrated that the M-DAC can be employed as a mirror platform with discrete displacement output for a noncontact surface profiling system.

  9. Solar Eclipse Effect on Shelter Air Temperature

    NASA Technical Reports Server (NTRS)

    Segal, M.; Turner, R. W.; Prusa, J.; Bitzer, R. J.; Finley, S. V.

    1996-01-01

    Decreases in shelter temperature during eclipse events were quantified on the basis of observations, numerical model simulations, and complementary conceptual evaluations. Observations for the annular eclipse on 10 May 1994 over the United States are presented, and these provide insights into the temporal and spatial changes in the shelter temperature. The observations indicated near-surface temperature drops of as much as 6 C. Numerical model simulations for this eclipse event, which provide a complementary evaluation of the spatial and temporal patterns of the temperature drops, predict similar decreases. Interrelationships between the temperature drop, degree of solar irradiance reduction, and timing of the peak eclipse are also evaluated for late spring, summer, and winter sun conditions. These simulations suggest that for total eclipses the drops in shelter temperature in midlatitudes can be as high as 7 C for a spring morning eclipse.

  10. Nondestructive hall coefficient measurements using ACPD techniques

    NASA Astrophysics Data System (ADS)

    Velicheti, Dheeraj; Nagy, Peter B.; Hassan, Waled

    2018-04-01

    Hall coefficient measurements offer great opportunities as well as major challenges for nondestructive materials characterization. The Hall effect is produced by the magnetic Lorentz force acting on moving charge carriers in the presence of an applied magnetic field. The magnetic perturbation gives rise to a Hall current that is normal to the conduction current but does not directly perturb the electric potential distribution. Therefore, Hall coefficient measurements usually exploit the so-called transverse galvanomagnetic potential drop effect that arises when the Hall current is intercepted by the boundaries of the specimen and thereby produce a measurable potential drop. In contrast, no Hall potential is produced in a large plate in the presence of a uniform normal field at quasi-static low frequencies. In other words, conventional Hall coefficient measurements are inherently destructive since they require cutting the material under tests. This study investigated the feasibility of using alternating current potential drop (ACPD) techniques for nondestructive Hall coefficient measurements in plates. Specifically, the directional four-point square-electrode configuration is investigated with superimposed external magnetic field. Two methods are suggested to make Hall coefficient measurements in large plates without destructive machining. At low frequencies, constraining the bias magnetic field can replace constraining the dimensions of the specimen, which is inherently destructive. For example, when a cylindrical permanent magnet is used to provide the bias magnetic field, the peak Hall voltage is produced when the diameter of the magnet is equal to the diagonal of the square ACPD probe. Although this method is less effective than cutting the specimen to a finite size, the loss of sensitivity is less than one order of magnitude even at very low frequencies. In contrast, at sufficiently high inspection frequencies the magnetic field of the Hall current induces a strong enough Hall electric field that produces measurable potential differences between points lying on the path followed by the Hall current even when it is not intercepted by either the edge of the specimen or the edge of the magnetic field. The induced Hall voltage increases proportionally to the square root of frequency as the current is squeezed into a shallow electromagnetic skin of decreasing depth. This approach could be exploited to measure the Hall coefficient near the surface at high frequencies without cutting the specimen.

  11. Deducing noninductive current profile from surface voltage evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litwin, C.; Wukitch, S.; Hershkowitz, N.

    Solving the resistive diffusion equation in the presence of a noninductive current source determines the time-evolution of the surface voltage. By inverting the problem the current drive profile can be determined from the surface voltage evolution. We show that under wide range of conditions the deduced profile is unique. If the conductivity profile is known, this method can be employed to infer the noninductive current profile, and, ipso facto, the profile of the total current. We discuss the application of this method to analyze the Alfven wave current drive experiments in Phaedrus-T.

  12. Pulmonary MRA: Differentiation of pulmonary embolism from truncation artifact

    PubMed Central

    Bannas, Peter; Schiebler, Mark L; Motosugi, Utaroh; François, Christopher J; Reeder, Scott B; Nagle, Scott K

    2015-01-01

    Purpose Truncation artifact (Gibbs ringing) causes central signal drop within vessels in pulmonary MRA that can be mistaken for emboli, reducing the diagnostic accuracy for pulmonary embolism (PE). We propose a quantitative approach to differentiate truncation artifact from PE. Methods Twenty-eight patients who underwent pulmonary CTA for suspected PE were recruited for pulmonary MRA. Signal intensity drops within pulmonary arteries that persisted on both arterial-phase and delayed-phase MRA were identified. The percent signal loss between the vessel lumen and central drop was measured. CTA served as the reference standard for presence of pulmonary emboli. Results A total of 65 signal intensity drops were identified on MRA. 48 (74%) of these were artifact and 17 (26%) were PE, as confirmed by CTA. Truncation artifacts had a significantly lower median signal drop than PE at both arterial-phase (26% [range 12–58%] vs. 85% [range 53–91%]) and at delayed-phase MRA (26% [range 11–55%] vs. 77% [range 47–89%]), p<0.0001 for both. ROC analyses revealed a threshold value of 51% (arterial-phase) and 47%-signal drop (delayed-phase) to differentiate between truncation artifact and PE with 100% sensitivity and >90% specificity. Conclusion Quantitative signal drop is an objective tool to help differentiate truncation artifact and pulmonary embolism in pulmonary MRA. PMID:24863886

  13. A Microscale Approach to Chemical Kinetics in the General Chemistry Laboratory: The Potassium Iodide Hydrogen Peroxide Iodine-Clock Reaction

    ERIC Educational Resources Information Center

    Sattsangi, Prem D.

    2011-01-01

    A microscale laboratory for teaching chemical kinetics utilizing the iodine clock reaction is described. Plastic pipets, 3 mL volume, are used to store and deliver precise drops of reagents and the reaction is run in a 24 well plastic tray using a total 60 drops of reagents. With this procedure, students determine the rate of reaction and the…

  14. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.

    PubMed

    Pan, Yu-Ning; Li, Ai-Jing; Chen, Xiao-Min; Wang, Jian; Ren, Da-Wei; Huang, Qiu-Li

    2016-04-01

    Using lower tube voltage can reduce the exposure to radiation and the dose of contrast agent. However, lower tube voltage is often linked to more noise and poor image quality, which create a need for more effective technology to resolve this problem. To explore the feasibility of coronary computed tomographic angiography (CCTA) in patients with obesity at low tube voltage (100 kV) and low contrast agent concentration (270 mg/mL) using iterative reconstruction. A total of 48 patients with body mass index greater than 30 kg/m(2) were included and randomly divided into two groups. Group A received a traditional protocol (iopromide 370 mg/mL + 120 kV); group B received a protocol with low tube voltage (100 kV), low contrast agent concentration (270 mg/mL), and iterative reconstruction. The effective dose (ED), average attenuation values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the figure of merit (FOM), image quality scores, and the total iodine intake were compared. No significant differences in average CT attenuations, SNR, CNR, and subjective scores were noticed between the two groups (P > 0.05), whereas the FOM of group B was significantly higher than that of group A. Effective radiation dose, total iodine, and iodine injection rate in group B were lower than those of group A (P <0.01). In patients with obesity, isotonic contrast agent with low iodine concentration and low-dose CCTA were feasible. Substantial reduction in radiation dose and the iodine intake could be achieved without compromising the image quality. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. The realization of an SVGA OLED-on-silicon microdisplay driving circuit

    NASA Astrophysics Data System (ADS)

    Bohua, Zhao; Ran, Huang; Fei, Ma; Guohua, Xie; Zhensong, Zhang; Huan, Du; Jiajun, Luo; Yi, Zhao

    2012-03-01

    An 800 × 600 pixel organic light-emitting diode-on-silicon (OLEDoS) driving circuit is proposed. The pixel cell circuit utilizes a subthreshold-voltage-scaling structure which can modulate the pixel current between 170 pA and 11.4 nA. In order to keep the voltage of the column bus at a relatively high level, the sample-and-hold circuits adopt a ping-pong operation. The driving circuit is fabricated in a commercially available 0.35 μm two-poly four-metal 3.3 V mixed-signal CMOS process. The pixel cell area is 15 × 15 μm2 and the total chip occupies 15.5 × 12.3 mm2. Experimental results show that the chip can work properly at a frame frequency of 60 Hz and has a 64 grayscale (monochrome) display. The total power consumption of the chip is about 85 mW with a 3.3V supply voltage.

  16. Voltage stress effects on microcircuit accelerated life test failure rates

    NASA Technical Reports Server (NTRS)

    Johnson, G. M.

    1976-01-01

    The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

  17. Forecasting of high voltage insulation performance: Testing of recommended potting materials and of capacitors

    NASA Technical Reports Server (NTRS)

    Bever, R. S.

    1984-01-01

    Nondestructive high voltage test techniques (mostly electrical methods) are studied to prevent total or catastrophic breakdown of insulation systems under applied high voltage in space. Emphasis is on the phenomenon of partial breakdown or partial discharge (P.D.) as a symptom of insulation quality, notably partial discharge testing under D.C. applied voltage. Many of the electronic parts and high voltage instruments in space experience D.C. applied stress in service, and application of A.C. voltage to any portion thereof would be prohibited. Suggestions include: investigation of the ramp test method for D.C. partial discharge measurements; testing of actual flight-type insulation specimen; perfect plotting resin samples with controlled defects for test; several types of plotting resins and recommendations of the better ones from the electrical characteristics; thermal and elastic properties are also considered; testing of commercial capaciters; and approximate acceptance/rejection/rerating criteria for sample test elements for space use, based on D.C. partial discharge.

  18. Boundary layer polarization and voltage in the 14 MLT region

    NASA Astrophysics Data System (ADS)

    Lundin, R.; Yamauchi, M.; Woch, J.; Marklund, G.

    1995-05-01

    Viking midlatitude observations of ions and electrons in the postnoon auroral region show that field-aligned acceleration of electrons and ions with energies up to a few kiloelectron volts takes place. The characteristics of the upgoing ion beams and the local transverse electric field observed by Viking indicate that parallel ion acceleration is primarily due to a quasi-electrostatic field-aligned acceleration process below Viking altitudes, i.e., below 10,000-13,500 km. A good correlation is found between the maximum upgoing ion beam energy and the depth of the local potential well determined by the Viking electric field experiment within dayside 'ion inverted Vs.' The total transverse potential throughout the entire region near the ion inverted Vs. is generally much higher than the field-aligned potential and may reach well above 10 kV. However, the detailed mapping of the transverse potential out to the boundary layer, a fundamental issue which remains controversial, was not attempted here. An important finding in this study is the strong correlation between the maximum up going ion beam energy of dayside ion inverted Vs and the solar wind velocity. This suggests a direct coupling of the solar wind plasma dynamo/voltage generator to the region of field-aligned particle acceleration. The fact that the center of dayside ion inverted Vs coincide with convection reversals/flow stagnation and upward Birkeland currents on what appears to be closed field lines (Woch et al., 1993), suggests that field-aligned potential structures connect to the inner part of an MHD dyanmo in the low-latitude boundary layer. Thus the Viking observations substantiate the idea of a solar wind induced boundary layer polarization where negatively charged perturbations in the postnoon sector persistently develops along the magnetic field lines, establishing accelerating potential drops along the geomagnetic field lines in the 0.5-10 kV range.

  19. Drop impact on thin liquid films using TIRM

    NASA Astrophysics Data System (ADS)

    Pack, Min; Ying Sun Team

    2015-11-01

    Drop impact on thin liquid films is relevant to a number of industrial processes such as pesticide spraying and repellent surface research such as self-cleaning applications. In this study, we systematically investigate the drop impact dynamics on thin liquid films on plain glass substrates by varying the film thickness, viscosity and impact velocity. High speed imaging is used to track the droplet morphology and trajectory over time as well as observing instability developments at high Weber number impacts. Moreover, the air layer between the drop and thin film upon drop impact is probed by total internal reflection microscopy (TIRM) where the grayscale intensity is used to measure the air layer thickness and spreading radius over time. For low We impact on thick films (We ~ 10), the effect of the air entrainment is pronounced where the adhesion of the droplet to the wall is delayed by the air depletion and liquid film drainage, whereas for high We impact (We >100) the air layer is no longer formed and instead, the drop contact with the wall is limited only to the film drainage for all film thicknesses. In addition, the maximum spreading radius of the droplet is analyzed for varying thin film thickness and viscosity.

  20. Dynamics of viscous drops confined in a rough medium

    NASA Astrophysics Data System (ADS)

    Keiser, Ludovic; Gas, Armelle; Jaafar, Khalil; Bico, Jose; Reyssat, Etienne

    2017-11-01

    We focus on the dynamics of viscous and non-wetting ``pancake'' droplets of oil conned in a vertical Hele-Shaw cell filled with a less viscous surfactant solution. These dense drops settle at constant velocity driven by gravity. The surfactant solution completely wets the walls, and a thin lubrication film separates the drops from the walls. With smooth walls, two main dynamical regimes are characterized as the gap between the walls is varied. Viscous dissipation is found to dominate either in the droplet or in the lubrication film, depending on the ratio of viscosities and length scales. A sharp transition between both regimes is observed and successfully captured by asymptotic models. With rough walls, that transition is dramatically altered. Drops are generally much slower in a rough Hele-Shaw cell, in comparison with a similar smooth cell. Building up on the seminal works of Seiwert et al. (J.F.M. 2011) on film deposition by dip coating on a rough surface, we shed light on the non-trivial friction processes resulting from the interplay of viscous dissipation at the front of the drop, in the lubrication film and in the bulk of the drop. We acknowledge funding from Total S.A.

  1. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    PubMed

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. Drop Tower Facility at Queensland University of Technology

    NASA Astrophysics Data System (ADS)

    Plagens, Owen; Castillo, Martin; Steinberg, Theodore; Ong, Teng-Cheong

    The Queensland University of Technology (QUT) Drop Tower Facility is a {raise.17exscriptstyle˜}2.1 second, 21.3 m fall, dual capsule drop tower system. The dual capsule comprises of an uncoupled exterior hollow drag shield that experiences drag by the ambient atmosphere with the experimental capsule falling within the drag shield. The dual capsule system is lifted to the top of the drop tower via a mechanical crane and the dropping process is initiated by the cutting of a wire coupling the experimental package and suspending the drag shield. The internal experimental capsule reaches the bottom of the drag shield floor just prior to the deceleration stage at the air bag and during this time experience gravity levels of {raise.17exscriptstyle˜}10textsuperscript{-6} g. The deceleration system utilizes an inflatable airbag where experimental packages can be designed to experience a maximum deceleration of {raise.17exscriptstyle˜}10textsuperscript{18} g for {raise.17exscriptstyle˜}0.1 seconds. The drag shield can house experimental packages with a maximum diameter of 0.8 m and height of 0.9 m. The drag shield can also be used in foam mode, where the walls are lined with foam and small experiments can be dropped completely untethered. This mode is generally used for the study of microsatellite manipulation. Payloads can be powered by on-board power systems with power delivered to the experiment until free fall occurs. Experimental data that can be collected includes but is not limited to video, temperature, pressure, voltage/current from the power supply, and triggering mechanisms outputs which are simultaneously collected via data logging systems and high speed video recording systems. Academic and commercial projects are currently under investigation at the QUT Drop Tower Facility and collaboration is openly welcome at this facility. Current research includes the study of heterogeneously burning metals in oxygen which is aimed at fire safety applications and identifying size distributions and morphologies of particles produced during the combustion of bulk metals. Materials produced via self-propagating high-temperature synthesis in microgravity are investigated to produce high electroluminescent materials and high efficient dye sensitized electrolyte materials. The rapid cooling and quenching of ZBLAN glass in a microgravity environment is studied to reduce crystallization in the glass. Convective pool boiling and nucleate bubble formation in nano-fluids is aimed at investigating heat transfer properties in these new materials which are masked by gravity. Novel carbon nanotubes are produced in low gravity via an arch discharge to investigate the formation mechanisms of these materials.

  3. Carvacrol modulates voltage-gated sodium channels kinetics in dorsal root ganglia.

    PubMed

    Joca, Humberto Cavalcante; Vieira, Daiana Cardoso Oliveira; Vasconcelos, Aliny Perreira; Araújo, Demetrius Antônio Machado; Cruz, Jader Santos

    2015-06-05

    Recent studies have shown that many of plant-derived compounds interact with specific ion channels and thereby modulate many sensing mechanisms, such as nociception. The monoterpenoid carvacrol (5-isopropyl-2-methylphenol) has an anti-nociceptive effect related to a reduction in neuronal excitability and voltage-gated Na(+) channels (NaV) inhibition in peripheral neurons. However, the detailed mechanisms of carvacrol-induced inhibition of neuronal NaV remain elusive. This study explores the interaction between carvacrol and NaV in isolated dorsal root ganglia neurons. Carvacrol reduced the total voltage-gated Na(+) current and tetrodotoxin-resistant (TTX-R) Na(+) current component in a concentration-dependent manner. Carvacrol accelerates current inactivation and induced a negative-shift in voltage-dependence of steady-state fast inactivation in total and TTX-R Na(+) current. Furthermore, carvacrol slowed the recovery from inactivation. Carvacrol provoked a leftward shift in both the voltage-dependence of steady-state inactivation and activation of the TTX-R Na(+) current component. In addition, carvacrol-induced inhibition of TTX-R Na(+) current was enhanced by an increase in stimulation frequency and when neurons were pre-conditioned with long depolarization pulse (5s at -50 mV). Taken all results together, we herein demonstrated that carvacrol affects NaV gating properties. The present findings would help to explain the mechanisms underlying the analgesic activity of carvacrol. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Novel switching method for single-phase NPC three-level inverter with neutral-point voltage control

    NASA Astrophysics Data System (ADS)

    Lee, June-Seok; Lee, Seung-Joo; Lee, Kyo-Beum

    2018-02-01

    This paper proposes a novel switching method with the neutral-point voltage control in a single-phase neutral-point-clamped three-level inverter (SP-NPCI) used in photovoltaic systems. A proposed novel switching method for the SP-NPCI improves the efficiency. The main concept is to fix the switching state of one leg. As a result, the switching loss decreases and the total efficiency is improved. In addition, it enables the maximum power-point-tracking operation to be performed by applying the proposed neutral-point voltage control algorithm. This control is implemented by modifying the reference signal. Simulation and experimental results provide verification of the performance of a novel switching method with the neutral-point voltage control.

  5. Centralized vs decentralized lunar power system study

    NASA Astrophysics Data System (ADS)

    Metcalf, Kenneth; Harty, Richard B.; Perronne, Gerald E.

    1991-09-01

    Three power-system options are considered with respect to utilization on a lunar base: the fully centralized option, the fully decentralized option, and a hybrid comprising features of the first two options. Power source, power conditioning, and power transmission are considered separately, and each architecture option is examined with ac and dc distribution, high and low voltage transmission, and buried and suspended cables. Assessments are made on the basis of mass, technological complexity, cost, reliability, and installation complexity, however, a preferred power-system architecture is not proposed. Preferred options include transmission based on ac, transmission voltages of 2000-7000 V with buried high-voltage lines and suspended low-voltage lines. Assessments of the total cost associated with the installations are required to determine the most suitable power system.

  6. Relationship between field-aligned currents and inverted-V parallel potential drops observed at midaltitudes

    NASA Astrophysics Data System (ADS)

    Sakanoi, T.; Fukunishi, H.; Mukai, T.

    1995-10-01

    The inverted-V field-aligned acceleration region existing in the altitude range of several thousand kilometers plays an essential role for the magnetosphere-ionosphere coupling system. The adiabatic plasma theory predicts a linear relationship between field-aligned current density (J∥) and parallel potential drop (Φ∥), that is, J∥=KΦ∥, where K is the field-aligned conductance. We examined this relationship using the charged particle and magnetic field data obtained from the Akebono (Exos D) satellite. The potential drop above the satellite was derived from the peak energy of downward electrons, while the potential drop below the satellite was derived from two different methods: the peak energy of upward ions and the energy-dependent widening of electron loss cone. On the other hand, field-aligned current densities in the inverted-V region were estimated from the Akebono magnetometer data. Using these potential drops and field-aligned current densities, we estimated the linear field-aligned conductance KJΦ. Further, we obtained the corrected field-aligned conductance KCJΦ by applying the full Knight's formula to the current-voltage relationship. We also independently estimated the field-aligned conductance KTN from the number density and the thermal temperature of magnetospheric source electrons which were obtained by fitting accelerated Maxwellian functions for precipitating electrons. The results are summarized as follows: (1) The latitudinal dependence of parallel potential drops is characterized by a narrow V-shaped structure with a width of 0.4°-1.0°. (2) Although the inverted-V potential region exactly corresponds to the upward field aligned current region, the latitudinal dependence of upward current intensity is an inverted-U shape rather than an inverted-V shape. Thus it is suggested that the field-aligned conductance KCJΦ changes with a V-shaped latitudinal dependence. In many cases, KCJΦ values at the edge of the inverted-V region are about 5-10 times larger than those at the center. (3) By comparing KCJΦ with KTN, KCJΦ is found to be about 2-20 times larger than KTN. These results suggest that low-energy electrons such as trapped electrons, secondary and back-scattered electrons, and ionospheric electrons significantly contribute to upward field-aligned currents in the inverted-V region. It is therefore inferred that non adiabatic pitch angle scattering processes play an important role in the inverted-V region. .

  7. Pulmonary MRA: differentiation of pulmonary embolism from truncation artefact.

    PubMed

    Bannas, Peter; Schiebler, Mark L; Motosugi, Utaroh; François, Christopher J; Reeder, Scott B; Nagle, Scott K

    2014-08-01

    Truncation artefact (Gibbs ringing) causes central signal drop within vessels in pulmonary magnetic resonance angiography (MRA) that can be mistaken for emboli, reducing diagnostic accuracy for pulmonary embolism (PE). We propose a quantitative approach to differentiate truncation artefact from PE. Twenty-eight patients who underwent pulmonary computed tomography angiography (CTA) for suspected PE were recruited for pulmonary MRA. Signal intensity drops within pulmonary arteries that persisted on both arterial-phase and delayed-phase MRA were identified. The percent signal loss between the vessel lumen and central drop was measured. CTA served as the reference standard for presence of pulmonary emboli. A total of 65 signal intensity drops were identified on MRA. Of these, 48 (74%) were artefacts and 17 (26%) were PE, as confirmed by CTA. Truncation artefacts had a significantly lower median signal drop than PE on both arterial-phase (26% [range 12-58%] vs. 85% [range 53-91%]) and delayed-phase MRA (26% [range 11-55%] vs. 77% [range 47-89%]), p < 0.0001 for both. Receiver operating characteristic (ROC) analyses revealed a threshold value of 51% (arterial phase) and 47% signal drop (delayed phase) to differentiate between truncation artefact and PE with 100% sensitivity and greater than 90% specificity. Quantitative signal drop is an objective tool to help differentiate truncation artefact and pulmonary embolism in pulmonary MRA. • Inexperienced readers may mistake truncation artefacts for emboli on pulmonary MRA • Pulmonary emboli have non-uniform signal drop • 51% (arterial phase) and 47% (delayed phase) cut-off differentiates truncation artefact from PE • Quantitative signal drop measurement enables more accurate pulmonary embolism diagnosis with MRA.

  8. Parallel Electric Field on Auroral Magnetic Field Lines.

    NASA Astrophysics Data System (ADS)

    Yeh, Huey-Ching Betty

    1982-03-01

    The interaction of Birkeland (magnetic-field-aligned) current carriers and the Earth's magnetic field results in electrostatic potential drops along magnetic field lines. The statistical distributions of the field-aligned potential difference (phi)(,(PARLL)) were determined from the energy spectra of electron inverted "V" events observed at ionospheric altitude for different conditions of geomagnetic activity as indicated by the AE index. Data of 1270 electron inverted "V"'s were obtained from Low-Energy Electron measurements of the Atmosphere Explorer-C and -D Satellite (despun mode) in the interval January 1974-April 1976. In general, (phi)(,(PARLL)) is largest in the dusk to pre-midnight sector, smaller in the post-midnight to dawn sector, and smallest in the near noon sector during quiet and disturbed geomagnetic conditions; there is a steady dusk-dawn-noon asymmetry of the global (phi)(,(PARLL)) distribution. As the geomagnetic activity level increases, the (phi)(,(PARLL)) pattern expands to lower invariant latitudes, and the magnitude of (phi)(,(PARLL)) in the 13-24 magnetic local time sector increases significantly. The spatial structure and intensity variation of the global (phi)(,(PARLL)) distribution are statistically more variable, and the magnitudes of (phi)(,(PARLL)) have smaller correlation with the AE-index, in the post-midnight to dawn sector. A strong correlation is found to exist between upward Birkeland current systems and global parallel potential drops, and between auroral electron precipitation patterns and parallel potential drops, regarding their mophology, their intensity and their dependence of geomagnetic activity. An analysis of the fine-scale simultaneous current-voltage relationship for upward Birkeland currents in Region 1 shows that typical field-aligned potential drops are consistent with model predictions based on linear acceleration of the charge carriers through an electrostatic potential drop along convergent magnetic field lines to maintain current continuity. In a steady state, this model of simple electrostatic acceleration without anomalous resistivity also predicts observable relations between global parallel currents and parallel potential drops and between global energy deposition and parallel potential drops. The temperature, density, and species of the unaccelerated charge carriers are the relevant parameters of the model. The dusk-dawn -noon asymmetry of the global (phi)(,(PARLL)) distribution can be explained by the above steady-state (phi)(,(PARLL)) process if we associate the source regions of upward Birkeland current carriers in Region 1, Region 2, and the cusp region with the plasma sheet boundary layer, the near-Earth plasma sheet, and the magnetosheath, respectively. The results of this study provide observational information on the global distribution of parallel potential drops and the prevailing process of generating and maintaining potential gradients (parallel electric fields) along auroral magnetic field lines.

  9. Voltage equalization of an ultracapacitor module by cell grouping using number partitioning algorithm

    NASA Astrophysics Data System (ADS)

    Oyarbide, E.; Bernal, C.; Molina, P.; Jiménez, L. A.; Gálvez, R.; Martínez, A.

    2016-01-01

    Ultracapacitors are low voltage devices and therefore, for practical applications, they need to be used in modules of series-connected cells. Because of the inherent manufacturing tolerance of the capacitance parameter of each cell, and as the maximum voltage value cannot be exceeded, the module requires inter-cell voltage equalization. If the intended application suffers repeated fast charging/discharging cycles, active equalization circuits must be rated to full power, and thus the module becomes expensive. Previous work shows that a series connection of several sets of paralleled ultracapacitors minimizes the dispersion of equivalent capacitance values, and also the voltage differences between capacitors. Thus the overall life expectancy is improved. This paper proposes a method to distribute ultracapacitors with a number partitioning-based strategy to reduce the dispersion between equivalent submodule capacitances. Thereafter, the total amount of stored energy and/or the life expectancy of the device can be considerably improved.

  10. Low-Actuation Voltage MEMS Digital-to-Analog Converter with Parylene Spring Structures

    PubMed Central

    Ma, Cheng-Wen; Lee, Fu-Wei; Liao, Hsin-Hung; Kuo, Wen-Cheng; Yang, Yao-Joe

    2015-01-01

    We propose an electrostatically-actuated microelectromechanical digital-to-analog converter (M-DAC) device with low actuation voltage. The spring structures of the silicon-based M-DAC device were monolithically fabricated using parylene-C. Because the Young’s modulus of parylene-C is considerably lower than that of silicon, the electrostatic microactuators in the proposed device require much lower actuation voltages. The actuation voltage of the proposed M-DAC device is approximately 6 V, which is less than one half of the actuation voltages of a previously reported M-DAC equipped with electrostatic microactuators. The measured total displacement of the proposed three-bit M-DAC is nearly 504 nm, and the motion step is approximately 72 nm. Furthermore, we demonstrated that the M-DAC can be employed as a mirror platform with discrete displacement output for a noncontact surface profiling system. PMID:26343682

  11. Fuel cell system

    DOEpatents

    Early, Jack; Kaufman, Arthur; Stawsky, Alfred

    1982-01-01

    A fuel cell system is comprised of a fuel cell module including sub-stacks of series-connected fuel cells, the sub-stacks being held together in a stacked arrangement with cold plates of a cooling means located between the sub-stacks to function as electrical terminals. The anode and cathode terminals of the sub-stacks are connected in parallel by means of the coolant manifolds which electrically connect selected cold plates. The system may comprise a plurality of the fuel cell modules connected in series. The sub-stacks are designed to provide a voltage output equivalent to the desired voltage demand of a low voltage, high current DC load such as an electrolytic cell to be driven by the fuel cell system. This arrangement in conjunction with switching means can be used to drive a DC electrical load with a total voltage output selected to match that of the load being driven. This arrangement eliminates the need for expensive voltage regulation equipment.

  12. Power conditioning unit for photovoltaic power systems

    NASA Astrophysics Data System (ADS)

    Beghin, G.; Nguyen Phuoc, V. T.

    Operational features and components of a power conditioning unit for interconnecting solar cell module powers with a utility grid are outlined. The two-stage unit first modifies the voltage to desired levels on an internal dc link, then inverts the current in 2 power transformers connected to a vector summation control to neutralize harmonic distortion up to the 11th harmonic. The system operates in parallel with the grid with extra inductors to absorb line-to-line voltage and phase differences, and permits peak power use from the PV array. Reactive power is gained internally, and a power system controller monitors voltages, frequencies, and currents. A booster preregulator adjusts the input voltage from the array to provide voltage regulation for the inverter, and can commutate 450 amps. A total harmonic distortion of less than 5 percent is claimed, with a rating of 5 kVA, 50/60 Hz, 3-phase, and 4-wire.

  13. Vermistabilization of textile mill sludge spiked with poultry droppings by an epigeic earthworm Eisenia foetida.

    PubMed

    Garg, V K; Kaushik, Priya

    2005-06-01

    Investigations were made to explore the potential of an epigeic earthworm Eisenia foetida to transform textile mill sludge spiked with poultry droppings in to value added product, i.e., vermicompost. The growth and reproduction of E. foetida was monitored in a range of different feed mixtures for 77 days in the laboratory under controlled experimental conditions. The maximum growth was recorded in 100% cow dung (CD). Replacement of poultry droppings by cow dung in feed mixtures and vice versa had little or no effect on worm growth rate and reproduction potential. Worms grew and reproduced favourably in 70% poultry droppings (PD)+30% solid textile mill sludge (STMS) and 60% PD+40% STMS feed mixtures. Greater percentage of STMS in the feed mixture significantly affected the biomass gain and cocoon production. Net weight gain by earthworms in 100% CD was 2.9-18.2 fold higher than different STMS containing feed mixtures. The mean number of cocoon production was between 23.4+/-4.65 (in 100% CD) and 3.6+/-1.04 (in 50% PD+50% STMS) cocoons earthworm(-1) for different feed mixtures tested. Vermicomposting resulted in significant reduction in C:N ratio and increase in nitrogen and phosphorus contents. Total potassium, total calcium and heavy metals (Fe, Zn, Pb and Cd) contents were lower in the final product than initial feed mixtures. Our trials demonstrated vermicomposting as an alternate technology for the recycling and environmentally safe disposal/management of textile mill sludge using an epigeic earthworm E. foetida if mixed with poultry droppings.

  14. Safety, efficacy, and patient acceptability of lidocaine hydrochloride ophthalmic gel as a topical ocular anesthetic for use in ophthalmic procedures

    PubMed Central

    Page, Michael A; Fraunfelder, Frederick W

    2009-01-01

    Purpose: To review the current literature on safety, efficacy, and measures of surgeon and patient satisfaction with lidocaine hydrochloride gel as a tool for ocular anesthesia. Methods: Pubmed search using keywords “lidocaine gel,” “ophthalmic,” and “surgery” and compiling cross-references. Twenty-six total references were reviewed, including 15 prospective randomized controlled trials (RCTs, total N = 933, average N = 62), 6 nonrandomized prospective studies (total N = 234, average N = 39), 2 animal studies, 1 microbiologic study, and 2 letters to the editor. Results: The RCTs and nonrandomized prospective studies evaluated a number of measures including timing of onset of anesthesia, duration of anesthesia, intraoperative and postoperative pain, need for additional anesthetic applications, intracameral lidocaine levels, and adverse effects. Control groups received topical drops, subconjunctival anesthetic, retrobulbar anesthetic, or sham gel. Lidocaine gel was shown to be at least as effective for pain control as alternative therapies in all studies, with longer duration of action than topical drops. Patient and surgeon satisfaction were high, and adverse effects were rare and comparable to those for anesthetic drop formulations. Surgical settings included cataract, pterygium, trabeculectomy, strabismus, intravitreal injection, vitrectomy, and penetrating keratoplasty. Conclusions: Lidocaine gel is a safe, effective, and potentially underutilized tool for ophthalmic surgery. PMID:19898665

  15. Correlation between performance in physics and prior mathematics knowledge

    NASA Astrophysics Data System (ADS)

    Hudson, H. T.; Rottmann, Ray M.

    The final grade of 1403 students enrolled in the first semester of the introductory, pre-professional physics course has been correlated with performance on a precourse diagnostic test of mathematical skills. The students were from a total of eight different sections taught by six separate instructors over a three year time span. The student population has been separated into two groups, those who completed the course (913 students) and those who dropped (490 students). The drops were assigned a projected final gradebased on performance up to date of withdrawal. The Pearson product-moment correlation for students who completed the course is 0.418 and correlation for the drops is 0.232. Both correlations are significant at the p < 0.001 level. This study suggests that prior mathematical ability is a primary influence on performance in the course, and has a secondary influence on the tendency to drop out of the course.

  16. Heat transfer in GTA welding arcs

    NASA Astrophysics Data System (ADS)

    Huft, Nathan J.

    Heat transfer characteristics of Gas Tungsten Arc Welding (GTAW) arcs with arc currents of 50 to 125 A and arc lengths of 3 to 11 mm were measured experimentally through wet calorimetry. The data collected were used to calculate how much heat reported to the cathode and anode and how much was lost from the arc column. A Visual Basic for Applications (VBA) macro was written to further analyze the data and account for Joule heating within the electrodes and radiation and convection losses from the arc, providing a detailed account of how heat was generated and dissipated within the system. These values were then used to calculate arc efficiencies, arc column voltages, and anode and cathode fall voltages. Trends were noted for variances in the arc column voltage, power dissipated from the arc column, and the total power dissipated by the system with changing arc length. Trends for variances in the anode and cathode fall voltages, total power dissipated, Joule heating within the torches and electrodes with changing arc current were also noted. In addition, the power distribution between the anode and cathode for each combination of arc length and arc current was examined. Keywords: Gas Tungsten Arc Welding, GTAW, anode fall, cathode fall, heat transfer, wet calorimetry

  17. The architecture design of a 2mW 18-bit high speed weight voltage type DAC based on dual weight resistance chain

    NASA Astrophysics Data System (ADS)

    Qixing, Chen; Qiyu, Luo

    2013-03-01

    At present, the architecture of a digital-to-analog converter (DAC) in essence is based on the weight current, and the average value of its D/A signal current increases in geometric series according to its digital signal bits increase, which is 2n-1 times of its least weight current. But for a dual weight resistance chain type DAC, by using the weight voltage manner to D/A conversion, the D/A signal current is fixed to chain current Icha; it is only 1/2n-1 order of magnitude of the average signal current value of the weight current type DAC. Its principle is: n pairs dual weight resistances form a resistance chain, which ensures the constancy of the chain current; if digital signals control the total weight resistance from the output point to the zero potential point, that could directly control the total weight voltage of the output point, so that the digital signals directly turn into a sum of the weight voltage signals; thus the following goals are realized: (1) the total current is less than 200 μA (2) the total power consumption is less than 2 mW; (3) an 18-bit conversion can be realized by adopting a multi-grade structure; (4) the chip area is one order of magnitude smaller than the subsection current-steering type DAC; (5) the error depends only on the error of the unit resistance, so it is smaller than the error of the subsection current-steering type DAC; (6) the conversion time is only one action time of switch on or off, so its speed is not lower than the present DAC.

  18. 2009 Michigan traffic crash facts

    DOT National Transportation Integrated Search

    2010-01-01

    In keeping with recent trends, traffic fatalities in 2009 were down to 871, a 11.1 : percent decrease from last year. The total number of persons injured also declined : 4.9 percent to 70,931 and total crashes dropped 7.9 percent to 290,978. Most : n...

  19. 2008 Michigan traffic crash facts

    DOT National Transportation Integrated Search

    2009-03-18

    In keeping with recent trends, traffic fatalities in 2008 were down to 980, a 9.6 : percent decrease from last year. The total number of persons injured also declined : 7.5 percent to 74,568 and total crashes dropped 2.5 percent to 316,057. Most : no...

  20. The effects of cathodic micro-voltage combined with hydrothermal pretreatment on methane fermentation of lignocellulose substrate

    NASA Astrophysics Data System (ADS)

    Liu, Dianxin; Ning, Ping; Qu, Guangfei; Huang, Xi; Liu, Yuhuan; Zhang, Jian

    2017-05-01

    The methane fermentation study assisted with cathodic micro-voltage was carried out to investigate the electric field effects on the fermentation of hydrothermally pretreated lignocellulose substrate. It was illustrated that a 0.25V cathode voltage and hydrothermal pretreatment could improve the biogas production, biogas quality and lignocellulose degradation ratio significantly. The cumulative biogas productions in the fermentation of hydrothermally pretreated cow dungs at 50°C, 150°C and 200°C with a 0.25V cathode voltage were observed in a total of 6640mL, 9218mL and 9456mL respectively over a detention time of 33 days. In comparison with the fermentation pretreated at 200°C without any voltage, nearly doubled of cumulative biogas production was obtained in the process of cathode-assisted fermentation. It was also observed that the daily methane content greater than or equal to 70% in the biogas generated with cathode voltage were clearly greater than that without voltages. Furthermore, the fermentation applied with a 0.25V cathode voltage had resulted into significant increases of 12.64% and 9.44% in lignin and cellulose degradation ratio relative to voltage free fermentation. And in the process of fermentation applied with cathode voltage, the final lignocellulose degradation ratio increased with the hydrothermal pretreatment temperature. Thus, the hydrothermal pretreatment and assisting fermentation with low cathode voltage can effectively promote the lignocellulose degradation. All results revealed that cathodic micro-voltage combined with hydrothermal pretreatment can remarkably improve the fermentation of lignocellulosic materials, indicating that a more effective fermentation technology can be developed by applying with cathodic micro-voltage.

Top