Sample records for traceability flow charts

  1. Development of the management for parenteral nutrition traceability in a standard hospital.

    PubMed

    Bernabeu Soria, Beatriz; Mateo García, Máxima; Wanden-Berghe, Carmina; Cervera Peris, Mercedes; Piñeiro Corrales, Guadalupe; Sanz-Valero, Javier

    2015-11-01

    to develop the traceability control and the hazard analysis in the processes of parenteral nutrients (PN). a standardized graphical notation was generated, describing in detail each of the stages in the overall process. The presence of hazards was analysed by sequencing decisions. The existence of Control Points (CP) or Critical Control Points (CCP) was estimated by Criticality Index (CI) for each hazard taking into account the probability of occurrence and the severity of the damage. The threshold for the IC was set in 6. a specific flow chart for the management and traceability of PN was obtained, defining each of the stages in CPs (validation and transcription of the prescription and administration) or CCPs (preparation, storage and infusion pump -flow and filter-). Stages regarding the delivery, the recovery and the recycle of the packing material of PNs are not considered CPs and, therefore, they were not included in the dashboard. PN must be dealt with in the frame of a standardized management system in order to improve patient safety, clinical relevance, maximize resource efficiency and minimize procedural issues. The proposed system provides a global management model whose steps are fully defined, allowing monitoring and verification of PN. It would be convenient to make use of a software application to support the monitoring of the traceability management and to store the historical records in order to evaluate the system. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  2. Uncertainty and Traceability for the CEESI Iowa Natural Gas Facility.

    PubMed

    Johnson, Aaron; Kegel, Tom

    2004-01-01

    This paper analyzes the uncertainty of a secondary flow measurement facility that calibrates a significant fraction of United States and foreign flow meters used for custody transfer of natural gas. The facility, owned by the Colorado Experimental Engineering Station Incorporated (CEESI), is located in Iowa. This facility measures flow with nine turbine meter standards, each of which is traceable to the NIST primary flow standard. The flow capacity of this facility ranges from 0.7 actual m(3)/s to 10.7 actual m(3)/s at nominal pressures of 7174 kPa and at ambient temperatures. Over this flow range the relative expanded flow uncertainty varies from 0.28 % to 0.30 % (depending on flow).

  3. Towards automated traceability maintenance

    PubMed Central

    Mäder, Patrick; Gotel, Orlena

    2012-01-01

    Traceability relations support stakeholders in understanding the dependencies between artifacts created during the development of a software system and thus enable many development-related tasks. To ensure that the anticipated benefits of these tasks can be realized, it is necessary to have an up-to-date set of traceability relations between the established artifacts. This goal requires the creation of traceability relations during the initial development process. Furthermore, the goal also requires the maintenance of traceability relations over time as the software system evolves in order to prevent their decay. In this paper, an approach is discussed that supports the (semi-) automated update of traceability relations between requirements, analysis and design models of software systems expressed in the UML. This is made possible by analyzing change events that have been captured while working within a third-party UML modeling tool. Within the captured flow of events, development activities comprised of several events are recognized. These are matched with predefined rules that direct the update of impacted traceability relations. The overall approach is supported by a prototype tool and empirical results on the effectiveness of tool-supported traceability maintenance are provided. PMID:23471308

  4. Study on Full Supply Chain Quality and Safetytraceability Systems For Cereal And Oilproducts

    NASA Astrophysics Data System (ADS)

    Liu, Shihong; Zheng, Huoguo; Meng, Hong; Hu, Haiyan; Wu, Jiangshou; Li, Chunhua

    Global food industry and Governments in many countries are putting increasing emphasis on establishment of food traceability systems. Food traceability has become an effective way in food safety management. Aimed at the major quality problems of cereal and oil products existing in the production, processing, warehousing, distribution and other links in the supply chain, this paper firstly proposes a new traceability framework combines the information flow with critical control points and quality indicators. Then it introduces traceability database design and data access mode to realize the framework. In practice, Code design for tracing goods is a challenge thing, so this paper put forward a code system based on UCC/EAN-128 standard.Middleware and Electronic terminal design are also briefly introduced to accomplish traceability system for cereal and oil products.

  5. The National Time and Frequency Service of the Russian Federation

    DTIC Science & Technology

    2004-09-01

    Krutikov Gosstandard of Russia, Moscow 119991, Russia V. Kostromin and N. Koshelyaevsky Institute of Metrology for Time and Space FGUP “ VNIIFTRI ...Metrology for Time and Space FGUP VNIIFTRI Mendeleevo 141570, Russia 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND...is supplied from reserved sources located in premises outside the main territory of VNIIFTRI . According to the State Traceability Chart for Time

  6. Modeling traceability information and functionality requirement in export-oriented tilapia chain.

    PubMed

    Zhang, Xiaoshuan; Feng, Jianying; Xu, Mark; Hu, Jinyou

    2011-05-01

    Tilapia has been named as the 'food fish of the 21st century' and has become the most important farmed fish. China is the world leader in tilapia production and export. Identifying information and functional requirements is critical in developing an efficient traceability system because traceability has become a fundamental prerequisite for exporting aquaculture products. This paper examines the export-oriented tilapia chains and information flow in the chains, and identifies the key actors, information requirements and information-capturing points. Unified Modeling Language (UML) technology is adopted to describe the information and functionality requirement for chain traceability. The barriers of traceability system adoption are also identified. The results show that the traceability data consist of four categories that must be recorded by each link in the chain. The functionality requirement is classified into four categories from the fundamental information record to decisive quality control; the top three barriers to the traceability system adoption are: high costs of implementing the system, lack of experienced and professional staff; and low level of government involvement and support. Copyright © 2011 Society of Chemical Industry.

  7. Umbilical venous catheters placement evaluation on frontal radiogram: application of a simplified flow-chart for radiology residents.

    PubMed

    Salerno, Sergio; Tudisca, Chiara; Murmura, Elena; Matranga, Domenica; La Tona, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio

    2017-05-01

    Umbilical Venous Catheter (UVC) are commonly used in neonatal period; they can be not correctly positioned and could be associated with complications. The purpose of this article is to suggest a flow-chart to evaluate the placement of UVC, testing it in young radiologists-in-training. We developed a simple flow-chart to asses, steps by step, UVC placement considering its course and tip location (ideally placed in the atriocaval junction). We tested the flow-chart impact asking to 20 residents to evaluate the placement of 10 UVC before and after they familiarized with the flow-chart and the anatomical findings of a newborn. The agreement among the 20 students was evaluated too. The number of correct characterizations was different due to the administration of the flow-chart. One hundred and six correct UVC assessments at the beginning switched to 196 after the administration of the flow-chart (p = 0.0001). The observed agreement among the twenty radiology residents was statistically significant, both before (kappa = 0.41, p < 0.001) and after (kappa = 0.37, p < 0.001) the flow-chart administration. The developed flow-chart demonstrated to be useful in increasing residents performance in UVC placement assessment.

  8. The Use of Flow Charts in Sediment Routing Analysis

    Treesearch

    Leslie M. Reid

    1982-01-01

    Flow charts are a widely used means of diagramming relationships among transport processes and storage sites during analyses of sediment routing. Because they have taken so many different forms, however, it is very difficult to use published flow charts to compare geomorphic systems. Though they generally are constructed to achieve the same purpose, flow charts...

  9. Predictive ability and efficacy for shortening door-to-balloon time of a new prehospital electrocardiogram-transmission flow chart in patients with ST-elevation myocardial infarction - Results of the CASSIOPEIA study.

    PubMed

    Sakai, Toshiaki; Nishiyama, Osamu; Onodera, Masayuki; Matsuda, Shigekatsu; Wakisawa, Shinobu; Nakamura, Motoyuki; Morino, Yoshihiro; Itoh, Tomonori

    2018-05-24

    The purposes of this study were to create a new flow-chart of prehospital electrocardiography (ECG)-transmission, evaluate its predictive ability for ST-elevation myocardial infarction (STEMI) and shorten door-to-balloon time (DTBT). The new transmission flow-chart was created using symptoms from previous medical records of STEMI patients. A total of 4090 consecutive patients transferred emergently to our hospital were divided into two groups: those in ambulances with an ECG-transmission device with the new flow-chart (ECGT-FC) and those transferred without an ECG-transmission device (non-ECGT) groups. A STEMI group comprising walk-in patients during the same period was used as a control group. The predictive ability of STEMI and the effectiveness of shortening the DTBT by the new flow-chart of ECG-transmission was evaluated. In the ECGT-FC group, the prevalence of STEMI in the ECG-transmission by the new flow-chart were significantly higher than in the non-ECG-transmission patients (6.71% vs. 0.19%; p<0.001). The sensitivity and specificity of the new ECG-transmission flow-chart were 83.3% and 88.1%, respectively. The median DTBT was significantly shortened (p=0.045) and the prevalence of DTBT<90min was significantly higher in the ECGT-FC group (p=0.018) than the other groups. The sensitivity and specificity of the new flow-chart for ECG-transmission were high. The new flow-chart combined with an ECG-transmission device could detect STEMI efficiently and shorten DTBT. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  10. The Second National Ballistics Imaging Comparison (NBIC-2)

    PubMed Central

    Vorburger, TV; Yen, J; Song, JF; Thompson, RM; Renegar, TB; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF’s National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. PMID:26601051

  11. The Second National Ballistics Imaging Comparison (NBIC-2).

    PubMed

    Vorburger, T V; Yen, J; Song, J F; Thompson, R M; Renegar, T B; Zheng, A; Tong, M; Ols, M

    2014-01-01

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

  12. Flow Charts: Visualization of Vector Fields on Arbitrary Surfaces

    PubMed Central

    Li, Guo-Shi; Tricoche, Xavier; Weiskopf, Daniel; Hansen, Charles

    2009-01-01

    We introduce a novel flow visualization method called Flow Charts, which uses a texture atlas approach for the visualization of flows defined over curved surfaces. In this scheme, the surface and its associated flow are segmented into overlapping patches, which are then parameterized and packed in the texture domain. This scheme allows accurate particle advection across multiple charts in the texture domain, providing a flexible framework that supports various flow visualization techniques. The use of surface parameterization enables flow visualization techniques requiring the global view of the surface over long time spans, such as Unsteady Flow LIC (UFLIC), particle-based Unsteady Flow Advection Convolution (UFAC), or dye advection. It also prevents visual artifacts normally associated with view-dependent methods. Represented as textures, Flow Charts can be naturally integrated into hardware accelerated flow visualization techniques for interactive performance. PMID:18599918

  13. BASIC Language Flow Charting Program (BASCHART). Technical Note 3-82.

    ERIC Educational Resources Information Center

    Johnson, Charles C.; And Others

    This document describes BASCHART, a computer aid designed to decipher and automatically flow chart computer program logic; it also provides the computer code necessary for this process. Developed to reduce the labor intensive manual process of producing a flow chart for an undocumented or inadequately documented program, BASCHART will…

  14. Formulae and Flow-Diagrams

    ERIC Educational Resources Information Center

    Willson, William Wynne

    1977-01-01

    The author recommends the use of flow charting to help students understand the manipulation of algebraic formulae. He identifies some problems with flow charts and suggests an alternative method of constructing flow diagrams. (SD)

  15. How to Read an LLNL Energy Flow Chart (Sankey Diagram)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, A. J.

    Each year, the Lawrence Livermore National Laboratory releases energy flow charts that illustrate the nation's consumption and use of energy. A.J. Simon, group leader for LLNL’s energy program, breaks the 2015 chart down in this video, describing how to read the chart and what year-to-year trends he sees.

  16. How to Read an LLNL Energy Flow Chart (Sankey Diagram)

    ScienceCinema

    Simon, A. J.

    2018-01-16

    Each year, the Lawrence Livermore National Laboratory releases energy flow charts that illustrate the nation's consumption and use of energy. A.J. Simon, group leader for LLNL’s energy program, breaks the 2015 chart down in this video, describing how to read the chart and what year-to-year trends he sees.

  17. School Mathematics Study Group, Unit Number Two. Chapter 3 - Informal Algorithms and Flow Charts. Chapter 4 - Applications and Mathematics Models.

    ERIC Educational Resources Information Center

    Stanford Univ., CA. School Mathematics Study Group.

    This is the second unit of a 15-unit School Mathematics Study Group (SMSG) mathematics text for high school students. Topics presented in the first chapter (Informal Algorithms and Flow Charts) include: changing a flat tire; algorithms, flow charts, and computers; assignment and variables; input and output; using a variable as a counter; decisions…

  18. The National Ballistics Imaging Comparison (NBIC) project.

    PubMed

    Song, J; Vorburger, T V; Ballou, S; Thompson, R M; Yen, J; Renegar, T B; Zheng, A; Silver, R M; Ols, M

    2012-03-10

    In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, a NIST/ATF joint project entitled National Ballistics Imaging Comparison (NBIC) was initialized in 2008. The NBIC project aims to establish a National Traceability and Quality System for ballistics identifications in crime laboratories within the National Integrated Ballistics Information Network (NIBIN) of the U.S. NIST Standard Reference Material (SRM) 2460 bullets and 2461 cartridge cases are used as reference standards. 19 ballistics examiners from 13 U.S. crime laboratories participated in this project. They each performed 24 periodic image acquisitions and correlations of the SRM bullets and cartridge cases over the course of a year, but one examiner only participated in Phase 1 tests of SRM cartridge case. The correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed Quality System and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard. Published by Elsevier Ireland Ltd.

  19. The role of psychological determinants and demographic factors in consumer demand for farm-to-fork traceability systems.

    PubMed

    Myae, Aye Chan; Goddard, Ellen; Aubeeluck, Ashwina

    2011-01-01

    Traceability systems are an important tool (1) for tracking, monitoring, and managing product flows through the supply chain for better efficiency and profitability of suppliers, and (2) to improve consumer confidence in the face of serious food safety incidents. After the global bovine spongiform encephalopathy (BSE) crisis affected producers, consumers, trade, and the health status of animals and humans, new systems to help confirm the status of cattle products along the supply chain from farm to fork were implemented in many countries (Trautman et al. 2008 ). In this study, people's overall food safety beliefs are explored with the main objective of measuring the link between their food safety beliefs and their attitudes toward traceability. A comparison is made among English-speaking Canadians, French-speaking Canadians, and Japanese consumers. In the study, an Internet-based survey was used to collect data from nationally representative samples of the population in Canada-English (1275), Canada-French (343), and Japanese (1940) in the summer of 2009. Respondents' interests in traceability systems are clearly linked to their sense that the industry is primarily responsible for any food safety outbreaks. Moreover, it is clear that certain segments of the population in all samples feel strongly about the importance of farm to fork traceability in beef; thus, policymakers may wish to consider extending traceability beyond the point of slaughter as a way of encouraging beef sales in Canada.

  20. Energy measurement using flow computers and chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beeson, J.

    1995-12-01

    Arkla Pipeline Group (APG), along with most transmission companies, went to electronic flow measurement (EFM) to: (1) Increase resolution and accuracy; (2) Real time correction of flow variables; (3) Increase speed in data retrieval; (4) Reduce capital expenditures; and (5) Reduce operation and maintenance expenditures Prior to EFM, mechanical seven day charts were used which yielded 800 pressure and differential pressure readings. EFM yields 1.2-million readings, a 1500 time improvement in resolution and additional flow representation. The total system accuracy of the EFM system is 0.25 % compared with 2 % for the chart system which gives APG improved accuracy.more » A typical APG electronic measurement system includes a microprocessor-based flow computer, a telemetry communications package, and a gas chromatograph. Live relative density (specific gravity), BTU, CO{sub 2}, and N{sub 2} are updated from the chromatograph to the flow computer every six minutes which provides accurate MMBTU computations. Because the gas contract length has changed from years to monthly and from a majority of direct sales to transports both Arkla and its customers wanted access to actual volumes on a much more timely basis than is allowed with charts. The new electronic system allows volumes and other system data to be retrieved continuously, if EFM is on Supervisory Control and Data Acquisition (SCADA) or daily if on dial up telephone. Previously because of chart integration, information was not available for four to six weeks. EFM costs much less than the combined costs of telemetry transmitters, pressure and differential pressure chart recorders, and temperature chart recorder which it replaces. APG will install this equipment on smaller volume stations at a customers expense. APG requires backup measurement on metering facilities this size. It could be another APG flow computer or chart recorder, or the other companies flow computer or chart recorder.« less

  1. Framework for Design of Traceability System on Organic Rice Certification

    NASA Astrophysics Data System (ADS)

    Purwandoko, P. B.; Seminar, K. B.; Sutrisno; Sugiyanta

    2018-05-01

    Nowadays, the preferences of organic products such as organic rice have been increased. It because of the people awareness of the healthy and eco-friendly food product consumption has grown. Therefore, it is very important to ensure organic quality of the product that will be produced. Certification is a series of process that holds to ensure the quality of products meets all criteria of organic standards. Currently, there is a problem that traceability information system for organic rice certification has been not available. The current system still conducts manually caused the loss of information during storage process. This paper aimed at developing a traceability framework on organic rice certification process. First, the main discussed issues are organic certification process. Second, unified modeling language (UML) is used to build the model of user requirement in order to develop traceability system for all actors in the certification process. Furthermore, the information captured model along certification process will be explained in this paper. The model shows the information flow that has to be recorded for each actor. Finally, the challenges in the implementation system will be discussed in this paper.

  2. Primary standards for measuring flow rates from 100 nl/min to 1 ml/min - gravimetric principle.

    PubMed

    Bissig, Hugo; Petter, Harm Tido; Lucas, Peter; Batista, Elsa; Filipe, Eduarda; Almeida, Nelson; Ribeiro, Luis Filipe; Gala, João; Martins, Rui; Savanier, Benoit; Ogheard, Florestan; Niemann, Anders Koustrup; Lötters, Joost; Sparreboom, Wouter

    2015-08-01

    Microflow and nanoflow rate calibrations are important in several applications such as liquid chromatography, (scaled-down) process technology, and special health-care applications. However, traceability in the microflow and nanoflow range does not go below 16 μl/min in Europe. Furthermore, the European metrology organization EURAMET did not yet validate this traceability by means of an intercomparison between different National Metrology Institutes (NMIs). The NMIs METAS, Centre Technique des Industries Aérauliques et Thermiques, IPQ, Danish Technological Institute, and VSL have therefore developed and validated primary standards to cover the flow rate range from 0.1 μl/min to at least 1 ml/min. In this article, we describe the different designs and methods of the primary standards of the gravimetric principle and the results obtained at the intercomparison for the upper flow rate range for the various NMIs and Bronkhorst High-Tech, the manufacturer of the transfer standards used.

  3. A novel diagram and complement to the CONSORT chart for presenting multimodal clinical trials.

    PubMed

    Schuller, Jan C; Mayer, Michael; Lanz, Doris; Schmitz, Shu-Fang Hsu; Brauchli, Peter; Leupin, Nicolas

    2009-05-01

    We developed a novel diagram to depict patient flow and outcomes in clinical trials. In contrast to flow diagrams such as the CONSORT chart, our diagram enables individual patient histories to be traced and depicts important patterns of treatment administration and outcomes, such as response and adverse events. Also, it is particularly useful for multimodal treatments or a sequence of different therapies where the CONSORT flow chart is less informative and can be confusing.

  4. Experimenting With Ore: Creating the Taconite Process; flow chart of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Experimenting With Ore: Creating the Taconite Process; flow chart of process - Mines Experiment Station, University of Minnesota, Twin Cities Campus, 56 East River Road, Minneapolis, Hennepin County, MN

  5. [Prospective comparison of the flow chart for laboratory investigations for anaemia from the Dutch College of General Practitioners' guideline 'Anaemia' with a self-developed, substantive and logistical alternative flow chart].

    PubMed

    Oosterhuis, W P; van der Horst, M; van Dongen, K; Ulenkate, H J L M; Volmer, M; Wulkan, R W

    2007-10-20

    To compare the flow diagram for the diagnosis of anaemia from the guideline 'Anaemia' from the Dutch College of General Practitioners (NHG) with a substantive and logistical alternative protocol. Prospective. For evaluation of anaemia, 124 patients from primary care reported to the laboratories of the St. Elisabeth Hospital in Tilburg (n = 94) and the Scheper Hospital in Emmen (n = 30), the Netherlands. Two flow charts were used: the NHG's flow chart and a self-developed chart in which not mean corpuscular volume, but ferritin concentration occupies the central position. All the laboratory tests mentioned in both flow charts were carried out in every patient with, for practical reasons, the exception of Hgb electrophoresis and bone marrow investigations. General practitioners were approached and patient dossiers were consulted to obtain further clinical data. According to the NHG protocol, on the grounds of the laboratory investigations, 64 (52%) of patients could not be put in a specific category. The majority were patients with normocytary anaemia who did not fulfil the criteria for iron deficiency anaemia or the anaemia of chronic disease. According to the alternative chart, in 36 (29%) patients no diagnosis was made. These were patients in whom no abnormal laboratory findings were observed, other than low haemoglobin values. The majority of the patients had normocytary anaemia, in some cases this was interpreted as the anaemia of chronic disease, but more often the anaemia could not be assigned to a particular category. A large number ofpatients had a raised creatinine value. This value did not appear in the NHG protocol. In 15% of patients, more than one cause for anaemia was found. The NHG protocol did not enable these multiple diagnoses to be made. Accordingly, the NHG protocol was difficult to implement in the laboratory. Using the NHG flow diagram a large percentage of patients could not be assigned to a particular category. Using the alternative flow diagram, which procedure is easier to carry out in the laboratory, it was possible to make multiple diagnoses.

  6. 23 CFR Appendix D to Subpart D of... - Equal Opportunity Compliance Review Process Flow Chart

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Equal Opportunity Compliance Review Process Flow Chart D Appendix D to Subpart D of Part 230 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION..., Subpt. D, App. D Appendix D to Subpart D of Part 230—Equal Opportunity Compliance Review Process Flow...

  7. Unstop the Logjams in Your Cash Flow.

    ERIC Educational Resources Information Center

    Everett, R. E.

    1989-01-01

    A cash flow analysis is charting expenditures and revenues against a factor of time. Explains how school systems can, by charting the congruency of revenues and expenditures carefully, develop an investment program to take maximum advantage of a positive cash position. (MLF)

  8. The stability cycle—A universal pathway for the stability of films over topography

    NASA Astrophysics Data System (ADS)

    Schörner, Mario; Aksel, Nuri

    2018-01-01

    In the present study on the linear stability of gravity-driven Newtonian films flowing over inclined topographies, we consider a fundamental question: Is there a universal principle, being valid to describe the parametric evolution of the flow's stability chart for variations of different system parameters? For this sake, we first screened all experimental and numerical stability charts available in the literature. In a second step, we performed experiments to fill the gaps which remained. Variations of the fluid's viscosity and the topography's specific shape, amplitude, wavelength, tip width, and inclination were considered. That way, we identified a set of six characteristic patterns of stability charts to be sufficient to describe and unify all results on the linear stability of Newtonian films flowing over undulated inclines. We unveiled a universal pathway—the stability cycle—along which the linear stability charts of all considered Newtonian films flowing down periodically corrugated inclines evolved when the system parameters were changed.

  9. AMPS data management requirements study, appendix 1. [user manuals (computer programs)/display devices - computerized simulation/experimentation/ionosphere

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Flow charts and display formats for the simulation of five experiments are given. The experiments are: (1) electromagnetic wave transmission; (2) passive observations of ambient plasma; (3) ionospheric measurements with subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustical gravity waves in the sodium layer using lasers. A detailed explanation of the simulation procedure, definition of variables, and an explanation of how the experimenter makes display choices is also presented. A functional description is included on each flow chart and the assumptions and definitions of terms and scope of the flow charts and displays are presented.

  10. Design and performance of a large vocabulary discrete word recognition system. Volume 2: Appendixes. [flow charts and users manual

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The users manual for the word recognition computer program contains flow charts of the logical diagram, the memory map for templates, the speech analyzer card arrangement, minicomputer input/output routines, and assembly language program listings.

  11. Honors: Getting Started.

    ERIC Educational Resources Information Center

    Etheridge, Sandra Y.

    This paper provides a description of the development of an honors program at Gulf Coast Community College (GCCC). The description is organized around three flow charts corresponding to different stages in the program's development, and which are followed by more detailed explanations. The first flow chart deals with program planning and…

  12. Flow Chart for Mineral Separation from Granitic Rocks.

    ERIC Educational Resources Information Center

    Mursky, Gregory

    1987-01-01

    Provided is a flow chart for the separation and purification of major, minor, and accessory minerals from granitic rocks. With careful use of heavy liquids, and a Franz Isodynamic Magnetic Separator, it is possible to obtain mineral concentrates with a purity of 95 percent or better. (Author/RH)

  13. SeaWiFS Science Algorithm Flow Chart

    NASA Technical Reports Server (NTRS)

    Darzi, Michael

    1998-01-01

    This flow chart describes the baseline science algorithms for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Data Processing System (SDPS). As such, it includes only processing steps used in the generation of the operational products that are archived by NASA's Goddard Space Flight Center (GSFC) Distributed Active Archive Center (DAAC). It is meant to provide the reader with a basic understanding of the scientific algorithm steps applied to SeaWiFS data. It does not include non-science steps, such as format conversions, and places the greatest emphasis on the geophysical calculations of the level-2 processing. Finally, the flow chart reflects the logic sequences and the conditional tests of the software so that it may be used to evaluate the fidelity of the implementation of the scientific algorithm. In many cases however, the chart may deviate from the details of the software implementation so as to simplify the presentation.

  14. Flow Charts for Determining Your Requirements: Nine Metal Fabrication and Finishing Source Categories Area Sources National Emission Standards for Hazardous Air Pollutants (NESHAP) Subpart XXXXXX

    EPA Pesticide Factsheets

    This page contains a July 2008 document that has flow charts to help determine if this National Emission Standards for Hazardous Air Pollutants (NESHAP) rule for Nine metal Fabrication and Finishing Area Source Categories applies to your facility.

  15. Problem Solving in a Middle School Robotics Design Classroom

    NASA Astrophysics Data System (ADS)

    Norton, Stephen J.; McRobbie, Campbell J.; Ginns, Ian S.

    2007-07-01

    Little research has been conducted on how students work when they are required to plan, build and evaluate artefacts in technology rich learning environments such as those supported by tools including flow charts, Labview programming and Lego construction. In this study, activity theory was used as an analytic tool to examine the social construction of meaning. There was a focus on the effect of teachers’ goals and the rules they enacted upon student use of the flow chart planning tool, and the tools of the programming language Labview and Lego construction. It was found that the articulation of a teacher’s goals via rules and divisions of labour helped to form distinct communities of learning and influenced the development of different problem solving strategies. The use of the planning tool flow charting was associated with continuity of approach, integration of problem solutions including appreciation of the nexus between construction and programming, and greater educational transformation. Students who flow charted defined problems in a more holistic way and demonstrated more methodical, insightful and integrated approaches to their use of tools. The findings have implications for teaching in design dominated learning environments.

  16. Evaluation of a diagnostic flow chart applying medical thoracoscopy, adenosine deaminase and T-SPOT.TB in diagnosis of tuberculous pleural effusion.

    PubMed

    He, Y; Zhang, W; Huang, T; Wang, X; Wang, M

    2015-10-01

    To evaluate a diagnostic flow chart applying medical thoracoscoy (MT), adenosine deaminase (ADA) and T-SPOT.TB in diagnosis of tuberculous pleural effusion (TPE) at a high TB burden country. 136 patients with pleural effusion (PE) were enrolled and divided into TPE and Non-TPE group. MT (histology), PE ADA and T-SPOT.TB were conducted on all patients. ROC analysis was performed for the best cut-off value of PE ADA in detection of TPE. The diagnostic flow chart applying MT, ADA and T-SPOT.TB was evaluated for improving the limitations of each diagnostic method. ROC analysis showed that the best cut-off value of PE ADA was 30U/L. The sensitivity and specificity of these tests were calculated respectively to be: 71.4% (58.5%-81.6%) and 100% (95.4-100.0%) for MT, 92.9% (83.0-97.2%) and 68.8% (57.9-77.9%) for T-SPOT.TB, and 80.0% (69.6-88.1%) and 92.9% (82.7-98.0%) for PE ADA. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value and negative predictive value of the diagnostic flow chart were 96.4% (87.9-99.0%), 96.3% (89.6-98.7%), 25.714, 0.037, 97.4 and 94.9, respectively. The diagnostic flow chart applying MT, ADA and T-SPOT.TB is an accurate and rapid diagnostic method in detection of TPE.

  17. MILSTAMP: Military Standard Transportation and Movement Procedures. Volume 1

    DTIC Science & Technology

    1987-03-15

    paragraphs changed. As it is a part of the regulation, the register will serve as a permanent, easily traceable record of all DoD transactions which affect ...resulting from political decisions, natural disasters, strikes, local or national regulatory action, or other actions which may affect normal traffic flow...regulatory action, or other actions which may affect normal traffic flow. (13) Evaluates carrier performance. 3. CONUS Airlift Managers a. The AFLC: (1

  18. Use of Audible and Chart-recorded Ultrasonography to Monitor Fetal Heart Rate and Uterine Blood Flow Parameters in Cattle

    USDA-ARS?s Scientific Manuscript database

    The objective of the present study was to evaluate the use of audible chart-recorded doppler ultrasonography (DUS) to monitor both uterine blood flow and fetal heart rate (FHR) during pregnancy in dairy cattle. Possible applications of DUS include the monitoring of fetal distress when a pregnancy be...

  19. Using Statistical Process Control to Make Data-Based Clinical Decisions.

    ERIC Educational Resources Information Center

    Pfadt, Al; Wheeler, Donald J.

    1995-01-01

    Statistical process control (SPC), which employs simple statistical tools and problem-solving techniques such as histograms, control charts, flow charts, and Pareto charts to implement continual product improvement procedures, can be incorporated into human service organizations. Examples illustrate use of SPC procedures to analyze behavioral data…

  20. A Quantitative Methodology for Determining the Critical Benchmarks for Project 2061 Strand Maps

    ERIC Educational Resources Information Center

    Kuhn, G.

    2008-01-01

    The American Association for the Advancement of Science (AAAS) was tasked with identifying the key science concepts for science literacy in K-12 students in America (AAAS, 1990, 1993). The AAAS Atlas of Science Literacy (2001) has organized roughly half of these science concepts or benchmarks into fifty flow charts. Each flow chart or strand map…

  1. Tularosa Basin Play Fairway Analysis: Methodology Flow Charts

    DOE Data Explorer

    Adam Brandt

    2015-11-15

    These images show the comprehensive methodology used for creation of a Play Fairway Analysis to explore the geothermal resource potential of the Tularosa Basin, New Mexico. The deterministic methodology was originated by the petroleum industry, but was custom-modified to function as a knowledge-based geothermal exploration tool. The stochastic PFA flow chart uses weights of evidence, and is data-driven.

  2. 9. Photocopy of command flow chart of NIKE Battalion, Headquarters ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photocopy of command flow chart of NIKE Battalion, Headquarters Battery and Missile Battery from Procedures and Drills for NIKE Ajax System, Department of the Army Field Manual, FM-44-80 from Institute for Military History, Carlisle Barracks, Carlisle, PA 1956 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI

  3. Computer assisted uroflowmetry diagnostic system

    NASA Astrophysics Data System (ADS)

    Makal, Jarosław; Idźkowski, Adam; Walendziuk, Wojciech

    2006-10-01

    In this paper an original uroflowmeter (called Adalbertus) has been presented. The device draws the flow chart and measures the parameters of urine flow. It is used in urological surgeries as an assistance in diagnosis of lower urinary track diseases like Benign Prostatic Hyperplasia (BPH). The measuring track and its main part - weight sensor have been described. Also the way of uncertainty calculation is mentioned. An example flow chart has been shown and the achieved results have been compared with a commercial product.

  4. Development of a weight/sizing design synthesis computer program. Volume 2: Program Description

    NASA Technical Reports Server (NTRS)

    Garrison, J. M.

    1973-01-01

    The program for the computerized analysis of weight estimation relationships for those elements of the space shuttle vehicle which contribute a significant portion of the inert weight is discussed. A listing of each module and subroutine of the program is presented. Included are a generalized flow chart describing the subroutine linkage of the complete program and detailed flow charts for each subprogram.

  5. Application of machine learning and expert systems to Statistical Process Control (SPC) chart interpretation

    NASA Technical Reports Server (NTRS)

    Shewhart, Mark

    1991-01-01

    Statistical Process Control (SPC) charts are one of several tools used in quality control. Other tools include flow charts, histograms, cause and effect diagrams, check sheets, Pareto diagrams, graphs, and scatter diagrams. A control chart is simply a graph which indicates process variation over time. The purpose of drawing a control chart is to detect any changes in the process signalled by abnormal points or patterns on the graph. The Artificial Intelligence Support Center (AISC) of the Acquisition Logistics Division has developed a hybrid machine learning expert system prototype which automates the process of constructing and interpreting control charts.

  6. Visualizing and Validating Metadata Traceability within the CDISC Standards.

    PubMed

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information.

  7. Visualizing and Validating Metadata Traceability within the CDISC Standards

    PubMed Central

    Hume, Sam; Sarnikar, Surendra; Becnel, Lauren; Bennett, Dorine

    2017-01-01

    The Food & Drug Administration has begun requiring that electronic submissions of regulated clinical studies utilize the Clinical Data Information Standards Consortium data standards. Within regulated clinical research, traceability is a requirement and indicates that the analysis results can be traced back to the original source data. Current solutions for clinical research data traceability are limited in terms of querying, validation and visualization capabilities. This paper describes (1) the development of metadata models to support computable traceability and traceability visualizations that are compatible with industry data standards for the regulated clinical research domain, (2) adaptation of graph traversal algorithms to make them capable of identifying traceability gaps and validating traceability across the clinical research data lifecycle, and (3) development of a traceability query capability for retrieval and visualization of traceability information. PMID:28815125

  8. SI-traceable and dynamic reference gas mixtures for water vapour at polar and high troposphere atmospheric levels

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Pascale, Céline; Mutter, Daniel; Wettstein, Sascha; Niederhauser, Bernhard

    2017-04-01

    In the framework of METAS' AtmoChem-ECV project, new facilities are currently being developed to generate reference gas mixtures for water vapour at concentrations measured in the high troposphere and polar regions, in the range 1-20 µmol/mol (ppm). The generation method is dynamic (the mixture is produced continuously over time) and SI-traceable (i.e. the amount of substance fraction in mole per mole is traceable to the definition of SI-units). The generation process is composed of three successive steps. The first step is to purify the matrix gas, nitrogen or synthetic air. Second, this matrix gas is spiked with the pure substance using a permeation technique: a permeation device contains a few grams of pure water in liquid form and loses it linearly over time by permeation through a membrane. In a third step, to reach the desired concentration, the first, high concentration mixture exiting the permeation chamber is then diluted with a chosen flow of matrix gas with one or two subsequent dilution steps. All flows are piloted by mass flow controllers. All parts in contact with the gas mixture are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. The mixture can eventually be directly used to calibrate an analyser. The standard mixture produced by METAS' dynamic setup was injected into a chilled mirror from MBW Calibration AG, the designated institute for absolute humidity calibration in Switzerland. The used chilled mirror, model 373LX, is able to measure frost point and sample pressure and therefore calculate the water vapour concentration. This intercomparison of the two systems was performed in the range 4-18 ppm water vapour in synthetic air, at two different pressure levels, 1013.25 hPa and 2000 hPa. We present here METAS' dynamic setup, its uncertainty budget and the first results of the intercomparison with MBW's chilled mirror.

  9. Modeling and Implementation of Cattle/Beef Supply Chain Traceability Using a Distributed RFID-Based Framework in China.

    PubMed

    Liang, Wanjie; Cao, Jing; Fan, Yan; Zhu, Kefeng; Dai, Qiwei

    2015-01-01

    In recent years, traceability systems have been developed as effective tools for improving the transparency of supply chains, thereby guaranteeing the quality and safety of food products. In this study, we proposed a cattle/beef supply chain traceability model and a traceability system based on radio frequency identification (RFID) technology and the EPCglobal network. First of all, the transformations of traceability units were defined and analyzed throughout the cattle/beef chain. Secondly, we described the internal and external traceability information acquisition, transformation, and transmission processes throughout the beef supply chain in detail, and explained a methodology for modeling traceability information using the electronic product code information service (EPCIS) framework. Then, the traceability system was implemented based on Fosstrak and FreePastry software packages, and animal ear tag code and electronic product code (EPC) were employed to identify traceability units. Finally, a cattle/beef supply chain included breeding business, slaughter and processing business, distribution business and sales outlet was used as a case study to evaluate the beef supply chain traceability system. The results demonstrated that the major advantages of the traceability system are the effective sharing of information among business and the gapless traceability of the cattle/beef supply chain.

  10. Modeling and Implementation of Cattle/Beef Supply Chain Traceability Using a Distributed RFID-Based Framework in China

    PubMed Central

    Liang, Wanjie; Cao, Jing; Fan, Yan; Zhu, Kefeng; Dai, Qiwei

    2015-01-01

    In recent years, traceability systems have been developed as effective tools for improving the transparency of supply chains, thereby guaranteeing the quality and safety of food products. In this study, we proposed a cattle/beef supply chain traceability model and a traceability system based on radio frequency identification (RFID) technology and the EPCglobal network. First of all, the transformations of traceability units were defined and analyzed throughout the cattle/beef chain. Secondly, we described the internal and external traceability information acquisition, transformation, and transmission processes throughout the beef supply chain in detail, and explained a methodology for modeling traceability information using the electronic product code information service (EPCIS) framework. Then, the traceability system was implemented based on Fosstrak and FreePastry software packages, and animal ear tag code and electronic product code (EPC) were employed to identify traceability units. Finally, a cattle/beef supply chain included breeding business, slaughter and processing business, distribution business and sales outlet was used as a case study to evaluate the beef supply chain traceability system. The results demonstrated that the major advantages of the traceability system are the effective sharing of information among business and the gapless traceability of the cattle/beef supply chain. PMID:26431340

  11. Analyzing Vehicle Operator Deviations

    DTIC Science & Technology

    2008-07-01

    Organization Report No. Scarborough A, Bailey L, Pounds J 9. Performing Organization Name and Address 10. Work Unit No. ( TRAIS ) FAA Civil...Investigation Reporting Form Instructions Use the accompanying flow charts (D4-D14) and Data Reporting Form (D15-D18) to document the results of the...happened, use the Entry Level Flow Chart (D3) to identify the relevant mental processes that were involved in the VOD. For each mental process identified

  12. System Study at SUNY College Bookstore/Oswego

    ERIC Educational Resources Information Center

    DeVita, Richard; And Others

    1975-01-01

    A system study of the textbook ordering department is presented including systems flow chart, chart of activities, and description of operations and procedures for utilizing the computer system. Changes based on the study are noted. (JT)

  13. Performance Charts for the Turbojet Engine

    NASA Technical Reports Server (NTRS)

    Pinkel, Benjamin; Karp, Irving M.

    1947-01-01

    Charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet engine for any given set of operating conditions and component efficiencies. The effects of the pressure losses in the inlet duct and combustion chamber, the variation in the physical properties of the gas as it passes through the cycle, and the change in mass flow by the addition of fuel are included. The principle performance charts show the effects of the primary variables and correction charts provide the effects of the secondary variables.

  14. Toward a New Brewing Control Chart for the 21st Century.

    PubMed

    Melrose, John; Roman-Corrochano, Borja; Montoya-Guerra, Marcela; Bakalis, Serafim

    2018-04-23

    This paper describes new results from a base model of brewing from a bed of packed coffee grains. The model solves for the diffusion of soluble species out of a distribution of particles into the flow through the bed pore space. It requires a limited set of input parameters. It gives a simple picture of the basic physics of coffee brewing and sets out a set of reduced variables for this process. The importance of bed extraction efficiency is elucidated. A coffee brewing control chart has been widely used to describe the region of ideal coffee brewing for some 50 years. A new chart is needed, however, one that connects actual brewing conditions (weight, flow rate, brew time, grind, etc.) to the yield and strength of brews. The paper shows a new approach to brewing control charts, including brew time and bed extraction efficiency as control parameters. Using the base model, an example chart will be given for a particular grind ratio of coarse to fine particles, and an "espresso regime" will be picked out. From such a chart yield, volume and strength of a brew can be read off at will.

  15. An Approach for Implementing a Microcomputer Based Report Origination System in the Ada Programming Language

    DTIC Science & Technology

    1983-03-01

    Decision Tree -------------------- 62 4-E. PACKAGE unitrep Action/Area Selection flow Chart 82 4-7. PACKAGE unitrep Control Flow Chart...the originetor wculd manually draft simple, readable, formatted iressages using "-i predef.ined forms and decision logic trees . This alternative was...Study Analysis DATA CCNTENT ERRORS PERCENT OF ERRORS Character Type 2.1 Calcvlations/Associations 14.3 Message Identification 4.? Value Pisiratch 22.E

  16. A Thermodynamic Study of the Turbojet Engine

    NASA Technical Reports Server (NTRS)

    Pinkel, Benjamin; Karp, Irvin M

    1947-01-01

    Charts are presented for computing thrust, fuel consumption, and other performance values of a turbojet engine for any given set of operating conditions and component efficiencies. The effects of pressure losses in the inlet duct and the combustion chamber, of variation in physical properties of the gas as it passes through the system, of reheating of the gas due to turbine losses, and of change in mass flow by the addition of fuel are included. The principle performance chart shows the effects of primary variables and correction charts provide the effects of secondary variables and of turbine-loss reheat on the performance of the system. The influence of characteristics of a given compressor and turbine on performance of a turbojet engine containing a matched set of these given components is discussed for cases of an engine with a centrifugal-flow compressor and of an engine with an axial-flow compressor.

  17. Program and charts for determining shock tube, and expansion tunnel flow quantities for real air

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1975-01-01

    A computer program in FORTRAN 4 language was written to determine shock tube, expansion tube, and expansion tunnel flow quantities for real-air test gas. This program permits, as input data, a number of possible combinations of flow quantities generally measured during a test. The versatility of the program is enhanced by the inclusion of such effects as a standing or totally reflected shock at the secondary diaphragm, thermochemical-equilibrium flow expansion and frozen flow expansion for the expansion tube and expansion tunnel, attenuation of the flow in traversing the acceleration section of the expansion tube, real air as the acceleration gas, and the effect of wall boundary layer on the acceleration section air flow. Charts which provide a rapid estimation of expansion tube performance prior to a test are included.

  18. Traceability

    PubMed Central

    2010-01-01

    The importance of effective and timely traceability in both the recall of substances of human origin (blood, cells, tissues and organs) implicated in infectious transmission, and in the prevention of inappropriate use of substances of human origin is now well recognised. However, traceability remains poorly understood and inadequately controlled in many cases. In particular there is: a lack of appreciation of the complexity of the traceability pathway; a fragmented approach to traceability; and, an assumption that traceability data is static. The traceability path for a single tissue donor may involve dozens or even hundreds of different organizations, each responsible for one segment of the path. Whilst responsibility within each organization may be clearly defined, responsibility for maintaining the interfaces between organizations is often less clear. Traceability is seldom regarded in a holistic manner, the assumption being made that if each segment of the pathway is correctly maintained then the full path will be intact. End to end traceability audits are not routinely performed, and the only true test of the trail occurs when recall is required—often with inadequate results. PMID:20628821

  19. The Expanding Role of Traceability in Seafood: Tools and Key Initiatives.

    PubMed

    Lewis, Sara G; Boyle, Mariah

    2017-08-01

    In the last decade, a range of drivers within the seafood sector have incentivized the application of traceability to issues beyond food safety and inventory management. Some of the issues motivating the expanded use of traceability within the global seafood sector include: increased media attention on the legal and social risks within some seafood supply chains, governmental traceability requirements, private-sector sustainability commitments, and others. This article begins with an overview of these topics in the seafood industry, and why many nongovernment organizations (NGOs), companies, and government actors have turned to traceability as a tool to address them. We discuss how traceability connects to key requirements of environmental sustainability and social responsibility. Later, we review the range of traceability services, tools, software solutions, and the due diligence measures that are currently being leveraged within the seafood sector. The paper concludes with a discussion of several NGO- and industry-led traceability initiatives that are examples of seafood traceability improvements. © 2017 Institute of Food Technologists®.

  20. Performance Charts for a Turbojet System

    NASA Technical Reports Server (NTRS)

    Karp, Irving M.

    1947-01-01

    Convenient charts are presented for computing the thrust, fuel consumption, and other performance values of a turbojet system. These charts take into account the effects of ram pressure, compressor pressure ratio, ratio of combustion-chamber-outlet temperature to atmospheric temperature, compressor efficiency, turbine efficiency, combustion efficiency, discharge-nozzle coefficient, losses in total pressure in the inlet to the jet-propulsion unit and in the combustion chamber, and variation in specific heats with temperature. The principal performance charts show clearly the effects of the primary variables and correction charts provide the effects of the secondary variables. The performance of illustrative cases of turbojet systems is given. It is shown that maximum thrust per unit mass rate of air flow occurs at a lower compressor pressure ratio than minimum specific fuel consumption. The thrust per unit mass rate of air flow increases as the combustion-chamber discharge temperature increases. For minimum specific fuel consumption, however, an optimum combustion-chamber discharge temperature exists, which in some cases may be less than the limiting temperature imposed by the strength temperature characteristics of present materials.

  1. OWL representation of the geologic timescale implementing stratigraphic best practice

    NASA Astrophysics Data System (ADS)

    Cox, S. J.

    2011-12-01

    The geologic timescale is a cornerstone of the earth sciences. Versions are available from many sources, with the following being of particular interest: (i) The official International Stratigraphic Chart (ISC) is maintained by the International Commission for Stratigraphy (ICS), following principles developed over the last 40 years. ICS provides the data underlying the chart as part of a specialized software package, and the chart itself as a PDF using the standard colours; (ii) ITC Enschede has developed a representation of the timescale as a thesaurus in SKOS, used in a Web Map Service delivery system; (iii) JPL's SWEET ontology includes a geologic timescale. This takes full advantage of the capabilities of OWL. However, each of these has limitations - The ISC falls down because of incompatibility with web technologies; - While SKOS supports multilingual labelling, SKOS does not adequately support timescale semantics, in particular since it does not include ordering relationships; - The SWEET version (as of version 2) is not fully aligned to the model used by ICS, in particular not recognizing the role of the Global Boundary Stratotype Sections and Point (GSSP). Furthermore, it is distributed as static documents, rather than through a dynamic API using SPARQL. The representation presented in this paper overcomes all of these limitations as follows: - the timescale model is formulated as an OWL ontology - the ontology is directly derived from the UML representation of the ICS best practice proposed by Cox & Richard [2005], and subsequently included as the Geologic Timescale package in GeoSciML (http://www.geosciml.org); this includes links to GSSPs as per the ICS process - key properties in the ontology are also asserted to be subProperties of SKOS properties (topConcept and broader/narrower relations) in order to support SKOS-based queries; SKOS labelling is used to support multi-lingual naming and synonyms - the International Stratigraphic Chart is implemented as a set of instances of classes from the ontology, and published through a SPARQL end-point - the elements of the Stratigraphic chart are linked to the corresponding elements in SWEET (Raskin et al., 2011) and DBpedia to support traceability between different commonly accessed representations. The ontology builds on standard geospatial information models, including the Observations and Measurements model (ISO 19156), and GeoSciML. This allows the ages given in the chart to be linked to the evidence basis found in the associated GeoSciML features.

  2. Coding and Flow Charting as Applied to UICSM Programed Texts (1962-1963 Versions). Comparative Studies of Principles for Programming Mathematics in Automated Instruction. Technical Report.

    ERIC Educational Resources Information Center

    Stolurow, Lawrence M.; And Others

    Coding systems need to be developed to account for computer decisions on every frame of a self-instructional program. In flow charts of the UICSM high school math programed series, each frame or page is represented by a diagramatic convention: diamond if a mainline frame, a rectangle if a quiz frame, a bottom-heavy trapezoid if a review or…

  3. The study of insect blood-feeding behaviour. 2. Recording techniques and the use of flow charts.

    PubMed

    Smith, J J; Friend, W G

    1987-01-01

    This paper continues a discussion of approaches and methodologies we have used in our studies of feeding in haematophagous insects. Described are techniques for directly monitoring behaviour: electrical recording of feeding behaviour via resistance changes in the food canal, optical methods for monitoring mouthpart activity, and a computer technique for behavioural event recording. Also described is the use of "flow charts" or "decision diagrams" to model interrelated sequences of behaviours.

  4. Evaluation of Shiryaev-Roberts procedure for on-line environmental radiation monitoring.

    PubMed

    Watson, Mara M; Seliman, Ayman F; Bliznyuk, Valery N; DeVol, Timothy A

    2018-04-30

    Water can become contaminated as a result of a leak from a nuclear facility, such as a waste facility, or from clandestine nuclear activity. Low-level on-line radiation monitoring is needed to detect these events in real time. A Bayesian control chart method, Shiryaev-Roberts (SR) procedure, was compared with classical methods, 3-σ and cumulative sum (CUSUM), for quantifying an accumulating signal from an extractive scintillating resin flow-cell detection system. Solutions containing 0.10-5.0 Bq/L of 99 Tc, as T99cO 4 - were pumped through a flow cell packed with extractive scintillating resin used in conjunction with a Beta-RAM Model 5 HPLC detector. While T99cO 4 - accumulated on the resin, time series data were collected. Control chart methods were applied to the data using statistical algorithms developed in MATLAB. SR charts were constructed using Poisson (Poisson SR) and Gaussian (Gaussian SR) probability distributions of count data to estimate the likelihood ratio. Poisson and Gaussian SR charts required less volume of radioactive solution at a fixed concentration to exceed the control limit in most cases than 3-σ and CUSUM control charts, particularly solutions with lower activity. SR is thus the ideal control chart for low-level on-line radiation monitoring. Once the control limit was exceeded, activity concentrations were estimated from the SR control chart using the control chart slope on a semi-logarithmic plot. A linear regression fit was applied to averaged slope data for five activity concentration groupings for Poisson and Gaussian SR control charts. A correlation coefficient (R 2 ) of 0.77 for Poisson SR and 0.90 for Gaussian SR suggest this method will adequately estimate activity concentration for an unknown solution. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. [Current progress in food geographical origin traceability by near infrared spectroscopy technology].

    PubMed

    Ma, Dong-Hong; Wang, Xi-Chang; Liu, Li-Ping; Liu, Yuan

    2011-04-01

    The geographical origin traceability of food, an important part of traceability system, is effective in protecting the quality and safety of foodstuffs. Near-infrared spectroscopy (NIR), which is a powerful technique for geographical origin traceability, has attracted extensive attention by scientists due to its speediness, non-pollution and simple operation. This paper presents the advantages and disadvantages of techniques that have been used for food geographical origin traceability. The basic principles of NIR and its applications in different food geographical origin traceability are presented too. Furthermore, problems in applications are analyzed and the future development trends are discussed.

  6. Visualizing human communication in business process simulations

    NASA Astrophysics Data System (ADS)

    Groehn, Matti; Jalkanen, Janne; Haho, Paeivi; Nieminen, Marko; Smeds, Riitta

    1999-03-01

    In this paper a description of business process simulation is given. Crucial part in the simulation of business processes is the analysis of social contacts between the participants. We will introduce a tool to collect log data and how this log data can be effectively analyzed using two different kind of methods: discussion flow charts and self-organizing maps. Discussion flow charts revealed the communication patterns and self-organizing maps are a very effective way of clustering the participants into development groups.

  7. THE DIFFERENTIAL DIAGNOSIS OF NON-SPECIFIC PARAESTHESIA ABOUT THE WRIST OR HAND USING A FLOW CHART

    PubMed Central

    Reggars, John W.

    1993-01-01

    A common clinical presentation in the Chiropractor's office is that of vague and unilateral paraesthesia of the wrist or hand. Often the patient is unable to identify any definite dermatomal pattern and in such cases an accurate diagnosis becomes somewhat difficult. The following paper, incorporating a flow chart, provides the clinician with a logical sequence for the clinical exam in an attempt to arrive at the correct diagnosis, particularly those with mechanical causes. PMID:17989743

  8. The Deming Method: Systems Theory for Educational Technology Services.

    ERIC Educational Resources Information Center

    Richie, Mark L.

    1993-01-01

    Discusses quality management principles as taught by W. Edwards Deming and describes their applications to educational technology services. Traditional organizational charts are explained; and benefits of using flow charts in Deming's systems are described, including better communications between departments, building teamwork, and opportunities…

  9. Teaching Electricity.

    ERIC Educational Resources Information Center

    Iona, Mario

    1982-01-01

    To clarify the meaning of electrical terms, a chart is used to compare electrical concepts and relationships with a more easily visualized system in which water flows from a hilltop reservoir through a pipe to drive a mill at the bottom of the hill. A diagram accompanies the chart. (Author/SK)

  10. Wisconsin Recertification Manual for Public Librarians.

    ERIC Educational Resources Information Center

    Fox, Robert; And Others

    Designed to assist public librarians certified after May 1, 1979, this manual explains Wisconsin recertification requirements based on continuing education. It provides continuing education guidelines, a flow chart of the recertification process, an individual learning activity form, an annual report form, a conversion chart for assignment of…

  11. [Traceability of labile blood products in Morocco: experience of the Ibn-Sina hospital of Rabat between 1999 and 2010].

    PubMed

    Ouadghiri, S; Atouf, O; Brick, C; Benseffaj, N; Essakalli, M

    2012-02-01

    The blood transfusion and haemovigilance service of the Ibn-Sina hospital in Rabat (Morocco) was created 1997. This unit manages the pretransfusional tests, distribution of blood products, traceability and haemovigilance. The objective of this study was to analyze, over a period of 12years, the traceability of blood products delivered in our hospital and the measures used to improve feedback information. This is a retrospective study conducted between 1999 and 2010. Traceability rate was calculated from the feedback of traceability forms supplied with blood products (number of blood products noted on traceability forms on the total number of delivered product). To improve traceability rate, several actions were undertaken: one-time training, awareness campaigns and call phones asking for feedback information. Between 1999 and 2010, the service has delivered 173,858 blood products. The average rate of traceability during this period was 13.4 %. Traceability rate varies widely over time (5.2 % in 1999, 15.5 % in 2010) and shows a maximum value of 27.2 % in 2005. Feedback information is lower in emergency departments than in medical and surgical services. Feedback information about traceability in Ibn-Sina hospital remains very poor despite the measures used. Other actions, such as continuous education courses, low enforcement and informatisation should be considered. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  12. Traceability of biotech-derived animals: application of DNA technology.

    PubMed

    Loftus, R

    2005-04-01

    Traceability is increasingly becoming standard across the agri-food industry, largely driven by recent food crises and the consequent demands for transparency within the food chain. This is leading to the development of a range of traceability concepts and technologies adapted to different industry needs. Experience with genetically modified plants has shown that traceability can play a role in increasing public confidence in biotechnology, and might similarly help allay concerns relating to the development of animal biotechnology. Traceability also forms an essential component of any risk management strategy and is a key requirement for post-marketing surveillance. Given the diversity of traceability concepts and technologies available, consideration needs to be given to the scope and precision of traceability systems for animal biotechnology. Experience to date has shown that conventional tagging and labelling systems can incorporate levels of error and may not have sufficient precision for biotech-derived animals. Deoxyribonucleic acid (DNA) technology can overcome these difficulties by tracing animals and animal by-products through their DNA code rather than an associated label. This offers the possibility of tracing some by-products of animal biotechnology through the supply chain back to source animals, offering unprecedented levels of traceability. Developments in both DNA sampling and analysis technology are making large-scale applications of DNA traceability increasingly cost effective and feasible, and are likely to lead to a broader uptake of DNA traceability concepts.

  13. Performance Prediction of a MongoDB-Based Traceability System in Smart Factory Supply Chains

    PubMed Central

    Kang, Yong-Shin; Park, Il-Ha; Youm, Sekyoung

    2016-01-01

    In the future, with the advent of the smart factory era, manufacturing and logistics processes will become more complex, and the complexity and criticality of traceability will further increase. This research aims at developing a performance assessment method to verify scalability when implementing traceability systems based on key technologies for smart factories, such as Internet of Things (IoT) and BigData. To this end, based on existing research, we analyzed traceability requirements and an event schema for storing traceability data in MongoDB, a document-based Not Only SQL (NoSQL) database. Next, we analyzed the algorithm of the most representative traceability query and defined a query-level performance model, which is composed of response times for the components of the traceability query algorithm. Next, this performance model was solidified as a linear regression model because the response times increase linearly by a benchmark test. Finally, for a case analysis, we applied the performance model to a virtual automobile parts logistics. As a result of the case study, we verified the scalability of a MongoDB-based traceability system and predicted the point when data node servers should be expanded in this case. The traceability system performance assessment method proposed in this research can be used as a decision-making tool for hardware capacity planning during the initial stage of construction of traceability systems and during their operational phase. PMID:27983654

  14. Performance Prediction of a MongoDB-Based Traceability System in Smart Factory Supply Chains.

    PubMed

    Kang, Yong-Shin; Park, Il-Ha; Youm, Sekyoung

    2016-12-14

    In the future, with the advent of the smart factory era, manufacturing and logistics processes will become more complex, and the complexity and criticality of traceability will further increase. This research aims at developing a performance assessment method to verify scalability when implementing traceability systems based on key technologies for smart factories, such as Internet of Things (IoT) and BigData. To this end, based on existing research, we analyzed traceability requirements and an event schema for storing traceability data in MongoDB, a document-based Not Only SQL (NoSQL) database. Next, we analyzed the algorithm of the most representative traceability query and defined a query-level performance model, which is composed of response times for the components of the traceability query algorithm. Next, this performance model was solidified as a linear regression model because the response times increase linearly by a benchmark test. Finally, for a case analysis, we applied the performance model to a virtual automobile parts logistics. As a result of the case study, we verified the scalability of a MongoDB-based traceability system and predicted the point when data node servers should be expanded in this case. The traceability system performance assessment method proposed in this research can be used as a decision-making tool for hardware capacity planning during the initial stage of construction of traceability systems and during their operational phase.

  15. A new portable generator to dynamically produce SI-traceable reference gas mixtures for VOCs and water vapour at atmospheric concentration

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Pascale, Céline; Ackermann, Andreas; Leuenberger, Daiana; Niederhauser, Bernhard

    2016-04-01

    In the framework of the KEY-VOCs and AtmoChem-ECV projects, we are currently developing new facilities to dynamically generate reference gas mixtures for a variety of reactive compounds, at concentrations measured in the atmosphere and in a SI-traceable way (i.e. the amount of substance fraction in mole per mole is traceable to SI-units). Here we present the realisation of such standards for water vapour in the range 1-10 μmol/mol and for volatile organic compounds (VOCs) such as limonene, alpha-pinene, MVK, MEK, in the nmol/mol range. The matrix gas can be nitrogen or synthetic air. Further development in gas purification techniques could make possible to use purified atmospheric air as carrier gas. The method is based on permeation and dynamic dilution: one permeator containing a pure substance (either water, limonene, MVK, MEK or α-pinene) is kept into a permeation chamber with a constant gas flow. The mass loss is precisely calibrated using a magnetic suspension balance. The carrier gas is purified beforehand from the compounds of interest to the required level, using commercially available purification cartridges. This primary mixture is then diluted to reach the required amount of substance fraction. All flows are piloted by mass flow controllers which makes the production process flexible and easily adaptable to generate the required concentration. All parts in contact with the gas mixture are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. Two setups are currently developed: one already built and fixed in our laboratory in Bern as well as a portable generator that is still under construction and that could be used anywhere in the field. The permeation chamber of the portable generator has multiple individual cells allowing the generation of mixtures up to 5 different components if needed. Moreover the presented technique can be adapted and applied to a large variety of molecules (e.g., NO2, BTEX, CFCs, HCFCs, HFCs and other refrigerants) and is particularly suitable for gas species and/or concentration ranges that are not stable in cylinders.

  16. Structured Analysis and the Data Flow Diagram: Tools for Library Analysis.

    ERIC Educational Resources Information Center

    Carlson, David H.

    1986-01-01

    This article discusses tools developed to aid the systems analysis process (program evaluation and review technique, Gantt charts, organizational charts, decision tables, flowcharts, hierarchy plus input-process-output). Similarities and differences among techniques, library applications of analysis, structured systems analysis, and the data flow…

  17. The implementation of traceability systems.

    PubMed

    Ammendrup, S; Barcos, L O

    2006-08-01

    Traceability is a tool to help countries meet their objectives of controlling, preventing and eradicating animal diseases. This article sets out the required steps in a traceability system. Before designing a system of traceability, one must identify the different characteristics that need to be traced throughout the various steps in the food production chain. The interaction between different sectors in defining the objectives and the resulting needs of a traceability system is fundamental. A clear legal framework is also indispensable. European Union (EU) legislation requires identification and registration for cattle, pigs, sheep and goats. For intra-EU trade these animals must be accompanied by a health certificate providing information on their identity and health status. The required identification is harmonised on an EU-wide basis with the aim of ensuring traceability for veterinary purposes. Furthermore EU legislation requires that the traceability of food, feed and food-producing animals be established at all stages of production.

  18. Helicopter rotor wake geometry and its influence in forward flight. Volume 2: Wake geometry charts

    NASA Technical Reports Server (NTRS)

    Egolf, T. A.; Landgrebe, A. J.

    1983-01-01

    Isometric and projection view plots, inflow ratio nomographs, undistorted axial displacement nomographs, undistorted longitudinal and lateral coordinates, generalized axial distortion nomographs, blade/vortex passage charts, blade/vortex intersection angle nomographs, and fore and aft wake boundary charts are discussed. Example condition, in flow ratio, undistorted axial location, longitudinal and lateral coordinates, axial coordinates distortions, blade/tip vortex intersections, angle of intersection, and fore and aft wake boundaries are also discussed.

  19. Traceability in healthcare: crossing boundaries.

    PubMed

    Lovis, C

    2008-01-01

    This paper is a survey on the problem of traceability in healthcare. Traceability covers many different aspects and its understanding varies among different players. In supply chains and retails, traceability usually covers aspects pertaining to logistics. The challenge is to keep trace of objects manufactured, to track their locations in a production and distribution processes. In food industry, traceability has received a lot of attention because of public health problems related to infectious diseases. For instance, in Europe, the challenge of traceability has been to build the tracking of meat, from the living animal to the shell. In the health sector, traceability has mostly been involved in patient safety around human products such as blood derivates contaminants or implanted devices and prosthesis such as mammary implants. There are growing interests involving traceability in health related to drug safety, including the problem of counterfeited drugs, and to privacy. Traceability is also increasingly seen as a mean to improve efficiency of the logistics of care and a way to better understand costs and usage of resources. This survey is reviewing the literature and proposes a discussion based on the real use and needs of traceability in a large teaching hospital. Traceability in healthcare is at the crossroads of numerous needs. It is therefore of particular complexity and raises many new challenges. Identification management and entity tracking, from serialization of consumers' good production in the supply chains, to the identification of actors, patients, care providers, locations and processes is a huge effort, tackling economical, political, ethical and technical challenges. New requirements are needed, not usually met in the supply chain, such as serialization and persistence in time. New problems arise, such as privacy and legal frameworks. There are growing needs to increase traceability for drug products, related to drug safety, counterfeited drugs, and to privacy. Technical problems around reliability, robustness and efficiency of carriers are still to be resolved. There is a lot at stakes. Traceability is a major aspect of the future in healthcare and requires the attention of the community of medical informatics.

  20. Syntax Flowcharts for Advanced French Courses.

    ERIC Educational Resources Information Center

    Bryant, William H.

    1983-01-01

    The use of syntax flow charts as a graphic illustration of syntactic rules is suggested as both an instructional and a heuristic tool. Charts for these French structures are presented: negating of verbal expressions; balancing of conditional tenses; use of imperfect versus compound; agreement of past participles; and subjunctive sequences. (MSE)

  1. Estimated Water Flows in 2005: United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C A; Belles, R D; Simon, A J

    2011-03-16

    Flow charts depicting water use in the United States have been constructed from publicly available data and estimates of water use patterns. Approximately 410,500 million gallons per day of water are managed throughout the United States for use in farming, power production, residential, commercial, and industrial applications. Water is obtained from four major resource classes: fresh surface-water, saline (ocean) surface-water, fresh groundwater and saline (brackish) groundwater. Water that is not consumed or evaporated during its use is returned to surface bodies of water. The flow patterns are represented in a compact 'visual atlas' of 52 state-level (all 50 states inmore » addition to Puerto Rico and the Virgin Islands) and one national water flow chart representing a comprehensive systems view of national water resources, use, and disposition.« less

  2. Getting With It: Flow Diagrams

    ERIC Educational Resources Information Center

    Ritchie, W. A.

    1975-01-01

    The use of flow charts in the teaching of college mathematics enhances students' understanding of mathematical processes. Used appropriately in elementary and secondary schools they could also nurture understanding of algorithms. (SD)

  3. The perceived value of dairy product traceability in modern society: An exploratory study.

    PubMed

    Charlebois, Sylvain; Haratifar, Sanaz

    2015-05-01

    The current study assessed the perceived value of food traceability in modern society by young consumers. After experiencing numerous recalls and food safety-related incidences, consumers are increasingly aware of the tools available to mitigate risks. Food traceability has been associated with food safety procedures for many years, but recent high-profile cases of food fraud around the world have given traceability a different strategic purpose. Focusing solely on dairy products, our survey results offer a glimpse of consumer perceptions of traceability as a means to preserve food integrity and authenticity. This study explored the various influences that market-oriented traceability has had on dairy consumers. For example, results show that if the dairy sector could guarantee that their product is in fact organic, 53.8% of respondents who often purchase organic milk would consider always purchasing traceable organic milk. This research produced a quantitative set of information related to the perceived value of food traceability, which could be useful for the creation and development of improved guidelines and better education for consumers. We discuss limitations and suggest areas for new research. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Augmented halal food traceability system: analysis and design using UML

    NASA Astrophysics Data System (ADS)

    Usman, Y. V.; Fauzi, A. M.; Irawadi, T. T.; Djatna, T.

    2018-04-01

    Augmented halal food traceability is expanding the range of halal traceability in food supply chain where currently only available for tracing from the source of raw material to the industrial warehouse or inbound logistic. The halal traceability system must be developed in the integrated form that includes inbound and outbound logistics. The objective of this study was to develop a reliable initial model of integrated traceability system of halal food supply chain. The method was based on unified modeling language (UML) such as use case, sequence, and business process diagram. A goal programming model was formulated considering two objective functions which include (1) minimization of risk of halal traceability failures happened potentially during outbound logistics activities and (2) maximization of quality of halal product information. The result indicates the supply of material is the most important point to be considered in minimizing the risk of failure of halal food traceability system whereas no risk observed in manufacturing and distribution.

  5. Communicating food safety, authenticity and consumer choice. Field experiences.

    PubMed

    Syntesa, Heiner Lehr

    2013-04-01

    The paper reviews patented and non-patented technologies, methods and solutions in the area of food traceability. It pays special attention to the communication of food safety, authenticity and consumer choice. Twenty eight recent patents are reviewed in the areas of (secure) identification, product freshness indicators, meat traceability, (secure) transport of information along the supply chain, country/region/place of origin, automated authentication, supply chain management systems, consumer interaction systems. In addition, solutions and pilot projects are described in the areas of Halal traceability, traceability of bird's nests, cold chain management, general food traceability and other areas.

  6. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  7. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  8. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  9. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  10. 21 CFR 820.65 - Traceability.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... QUALITY SYSTEM REGULATION Identification and Traceability § 820.65 Traceability. Each manufacturer of a device that is intended for surgical implant into the body or to support or sustain life and whose...

  11. Programmers manual for static and dynamic reusable surface insulation stresses (resist)

    NASA Technical Reports Server (NTRS)

    Ogilvie, P. L.; Levy, A.; Austin, F.; Ojalvo, I. U.

    1974-01-01

    Programming information for the RESIST program for the dynamic and thermal stress analysis of the space shuttle surface insulation is presented. The overall flow chart of the program, overlay chart, data set allocation, and subprogram calling sequence are given along with a brief description of the individual subprograms and typical subprogram output.

  12. Tables for the Rapid Estimation of Downwash and Sidewash Behind Wings Performing Various Motions at Supersonic Speeds

    NASA Technical Reports Server (NTRS)

    Bobbitt, Percy J.

    1959-01-01

    Equations for the downwash and sidewash due to supersonic yawed and unswept horseshoe vortices have been utilized in formulating tables and charts to permit a rapid estimation of the flow velocities behind wings performing various steady motions. Tabulations are presented of the downwash and sidewash in the wing vertical plane of symmetry due to a unit-strength yawed horseshoe vortex located at 20 equally spaced spanwise positions along lifting lines of various sweeps. (The bound portion of the yawed vortex is coincident with the lifting line.) Charts are presented for the purpose of estimating the spanwise variations of the flow-field velocities and give longitudinal variations of the downwash and sidewash at a nuMber of vertical and spanwise locations due to a unit-strength unswept horseshoe vortex. Use of the tables and charts to calculate wing downwash or sidewash requires a knowledge of the wing spanwise distribution of circulation. Sample computations for the rolling sidewash and angle-of-attack downwash behind a typical swept wing are presented to demonstrate the use of the tables and charts.

  13. Using Flow Charts to Visualize the Decision-Making Process in Space Weather Forecasting

    NASA Astrophysics Data System (ADS)

    Aung, M. T. Y.; Myat, T.; Zheng, Y.; Mays, M. L.; Ngwira, C.; Damas, M. C.

    2016-12-01

    Our society today relies heavily on technological systems such as satellites, navigation systems, power grids and aviation. These systems are very sensitive to space weather disturbances. When Earth-directed space weather driven by the Sun arrives at the Earth, it causes changes to the Earth's radiation environment and the magnetosphere. Strong disturbances in the magnetosphere of the Earth are responsible for geomagnetic storms that can last from hours to days depending on strength of storms. Geomagnetic storms can severely impact critical infrastructure on Earth, such as the electric power grid, and Solar Energetic Particles that can endanger life in outer space. How can we lessen these adverse effects? They can be lessened through the early warning signals sent by space weather forecasters before CME or high-speed stream arrives. A space weather forecaster's duty is to send predicted notifications to high-tech industries and NASA missions so that they could take extra measures for protection. NASA space weather forecasters make prediction decisions by following certain steps and processes from the time an event occurs at the sun all the way to the impact locations. However, there has never been a tool that helps these forecasters visualize the decision process until now. A flow chart is created to help forecasters visualize the decision process. This flow chart provides basic knowledge of space weather and can be used to train future space weather forecasters. It also helps to cut down the training period and increase consistency in forecasting. The flow chart is also a great reference for people who are already familiar with space weather.

  14. [Oral contraception].

    PubMed

    Montloin, A

    1990-11-01

    This brief discussion of the different types of oral contraceptives (OCs) makes abundant use of flow charts, tables, and diagrams to present information and stress specific points. The work begins by defining the different hypothalamic, pituitary, and ovarian hormones and diagramming and describing the menstrual cycle. A discussion of combined OCs defines and diagrams monophasic, biphasic, and triphasic pills, distinguishes between different dose levels, and describes the mechanisms of action of OCs. Sequential pills and their mechanism of action are briefly discussed. The discussion of OCs containing progestins distinguishes between low does pills and high dose pills and describes the use of injectable progestins. A table then lists the dose-dependent side effects of estrogens and progestins. Simple instructions are provided for administering pills beginning on the 1st cycle day and for actions to take in the event a pill is forgotten. A flow chart taking into account age and presence or absence of vascular and gynecologic risk factors indicates which type of OC should be selected. Some advantages of OCs are identified, including maximum effectiveness and prevention of benign breast disease and perhaps of some type of rheumatoid arthritis. Another flow chart, on patient monitoring, identifies the contraindications that should be ruled out before OCs are prescribed and the routine follow-up examinations required for safe use. Other charts list absolute and relative contraindications and possible drug interferences.

  15. Portable traceability solution for ground-based calibration of optical instruments

    NASA Astrophysics Data System (ADS)

    El Gawhary, Omar; van Veghel, Marijn; Kenter, Pepijn; van der Leden, Natasja; Dekker, Paul; Revtova, Elena; Heemskerk, Maurice; Trarbach, André; Vink, Ramon; Doyle, Dominic

    2017-11-01

    We present a portable traceability solution for the ground-based optical calibration of earth observation (EO) instruments. Currently, traceability for this type of calibration is typically based on spectral irradiance sources (e.g. FEL lamps) calibrated at a national metrology institute (NMI). Disadvantages of this source-based traceability are the inflexibility in operating conditions of the source, which are limited to the settings used during calibration at the NMI, and the susceptibility to aging, which requires frequent recalibrations, and which cannot be easily checked on-site. The detector-based traceability solution presented in this work uses a portable filter radiometer to calibrate light sources onsite, immediately before and after, or even during instrument calibration. The filter radiometer itself is traceable to the primary standard of radiometry in the Netherlands. We will discuss the design and realization, calibration and performance verification.

  16. Banning PRF programmer's manual. [considering MOS integrated circuits

    NASA Technical Reports Server (NTRS)

    Kuelthau, R. L.

    1970-01-01

    This manual describes a modification of the Banning placement routing folding program. The modifications to this program have been made to implement it on a Sigma 5 computer. Flow charts of various levels, beginning with high level functional diagrams and working down to the level of detail deemed necessary to understand the operations of the various sections of the program are included. Along with the flow charts of each subroutine is a narrative description of its functional operation and definitions of its arrays and key variables, and a section to assist the programmer in dimensioning the program's arrays.

  17. HAL/SM system functional design specification. [systems analysis and design analysis of central processing units

    NASA Technical Reports Server (NTRS)

    Ross, C.; Williams, G. P. W., Jr.

    1975-01-01

    The functional design of a preprocessor, and subsystems is described. A structure chart and a data flow diagram are included for each subsystem. Also a group of intermodule interface definitions (one definition per module) is included immediately following the structure chart and data flow for a particular subsystem. Each of these intermodule interface definitions consists of the identification of the module, the function the module is to perform, the identification and definition of parameter interfaces to the module, and any design notes associated with the module. Also described are compilers and computer libraries.

  18. How well do commonly used data presentation formats support comparative effectiveness evaluations?

    PubMed Central

    Dolan, James G.; Qian, Feng; Veazie, Peter J.

    2012-01-01

    Background Good decisions depend on an accurate understanding of the comparative effectiveness of decision alternatives. The best way convey data needed to support these comparisons is unknown. Objective To determine how well five commonly used data presentation formats convey comparative effectiveness information. Design Internet survey using a factorial design. Subjects 279 members of an online survey panel. Intervention Study participants compared outcomes associated with three hypothetical screening test options relative to five possible outcomes with probabilities ranging from 2 per 5,000 (0.04%) to 500 per 1,000 (50%). Data presentation formats included a table, a “magnified” bar chart, a risk scale, a frequency diagram, and an icon array. Measurements Outcomes included the number of correct ordinal judgments regarding the more likely of two outcomes, the ratio of perceived versus actual relative likelihoods of the paired outcomes, the inter-subject consistency of responses, and perceived clarity. Results The mean number of correct ordinal judgments was 12 of 15 (80%), with no differences among data formats. On average, there was a 3.3-fold difference between perceived and actual likelihood ratios,95%CI: 3.0 to 3.6. Comparative judgments based on flow charts, icon arrays, and tables were all significantly more accurate and consistent than those based on risk scales and bar charts, p < 0.001. The most clearly perceived formats were the table and the flow chart. Low subjective numeracy was associated with less accurate and more variable data interpretations and lower perceived clarity for icon displays, bar charts, and flow diagrams. Conclusions None of the data presentation formats studied can reliably provide patients, especially those with low subjective numeracy, with an accurate understanding of comparative effectiveness information. PMID:22618998

  19. Locations of ectopic beats coincide with spatial gradients of NADH in a regional model of low-flow reperfusion.

    PubMed

    Kay, Matthew; Swift, Luther; Martell, Brian; Arutunyan, Ara; Sarvazyan, Narine

    2008-05-01

    We studied the origins of ectopic beats during low-flow reperfusion after acute regional ischemia in excised rat hearts. The left anterior descending coronary artery was cannulated. Perfusate was delivered to the cannula using an high-performance liquid chromatography pump. This provided not only precise control of flow rate but also avoided mechanical artifacts associated with vessel occlusion and deocclusion. Optical mapping of epicardial transmembrane potential served to identify activation wavefronts. Imaging of NADH fluorescence was used to quantify local ischemia. Our experiments suggest that low-flow reperfusion of ischemic myocardium leads to a highly heterogeneous ischemic substrate and that the degree of ischemia between adjacent patches of tissue changes in time. In contrast to transient ectopic activity observed during full-flow reperfusion, persistent ectopic arrhythmias were observed during low-flow reperfusion. The origins of ectopic beats were traceable to areas of high spatial gradients of changes in NADH fluorescence caused by low-flow reperfusion.

  20. The Two-By-Two Array: An Aid in Conceptualization and Problem Solving

    ERIC Educational Resources Information Center

    Eberhart, James

    2004-01-01

    The fields of mathematics, science, and engineering are replete with diagrams of many varieties. They range in nature from the Venn diagrams of symbolic logic to the Periodic Chart of the Elements; and from the fault trees of risk assessment to the flow charts used to describe laboratory procedures, industrial processes, and computer programs. All…

  1. An algorithmic approach to the brain biopsy--part I.

    PubMed

    Kleinschmidt-DeMasters, B K; Prayson, Richard A

    2006-11-01

    The formulation of appropriate differential diagnoses for a slide is essential to the practice of surgical pathology but can be particularly challenging for residents and fellows. Algorithmic flow charts can help the less experienced pathologist to systematically consider all possible choices and eliminate incorrect diagnoses. They can assist pathologists-in-training in developing orderly, sequential, and logical thinking skills when confronting difficult cases. To present an algorithmic flow chart as an approach to formulating differential diagnoses for lesions seen in surgical neuropathology. An algorithmic flow chart to be used in teaching residents. Algorithms are not intended to be final diagnostic answers on any given case. Algorithms do not substitute for training received from experienced mentors nor do they substitute for comprehensive reading by trainees of reference textbooks. Algorithmic flow diagrams can, however, direct the viewer to the correct spot in reference texts for further in-depth reading once they hone down their diagnostic choices to a smaller number of entities. The best feature of algorithms is that they remind the user to consider all possibilities on each case, even if they can be quickly eliminated from further consideration. In Part I, we assist the resident in learning how to handle brain biopsies in general and how to distinguish nonneoplastic lesions that mimic tumors from true neoplasms.

  2. An algorithmic approach to the brain biopsy--part II.

    PubMed

    Prayson, Richard A; Kleinschmidt-DeMasters, B K

    2006-11-01

    The formulation of appropriate differential diagnoses for a slide is essential to the practice of surgical pathology but can be particularly challenging for residents and fellows. Algorithmic flow charts can help the less experienced pathologist to systematically consider all possible choices and eliminate incorrect diagnoses. They can assist pathologists-in-training in developing orderly, sequential, and logical thinking skills when confronting difficult cases. To present an algorithmic flow chart as an approach to formulating differential diagnoses for lesions seen in surgical neuropathology. An algorithmic flow chart to be used in teaching residents. Algorithms are not intended to be final diagnostic answers on any given case. Algorithms do not substitute for training received from experienced mentors nor do they substitute for comprehensive reading by trainees of reference textbooks. Algorithmic flow diagrams can, however, direct the viewer to the correct spot in reference texts for further in-depth reading once they hone down their diagnostic choices to a smaller number of entities. The best feature of algorithms is that they remind the user to consider all possibilities on each case, even if they can be quickly eliminated from further consideration. In Part II, we assist the resident in arriving at the correct diagnosis for neuropathologic lesions containing granulomatous inflammation, macrophages, or abnormal blood vessels.

  3. An Initial Model of Requirements Traceability an Empirical Study

    DTIC Science & Technology

    1992-09-22

    procedures have been used extensively in the study of human problem-solving, including such areas as general problem-solving behavior, physics problem...heen doing unless you have traceability." " Humans don’t go back to the requirements enough." "Traceabi!ity should be extremely helpful with...by constraints on its usage: ("Traceability needs to be something that humans can work with, not just a whip held over people." "Traceability should

  4. Practical Use Of It In Traceability In Food Value Chains

    NASA Astrophysics Data System (ADS)

    Ratcliff, Jon; Boddington, Michael

    Traceability is today considered an essential requirement for the food value chain due to the need to provide consumers with accurate information in the event of food safety recalls, to provide assurance with regard the source and production systems for food products and in certain countries to comply with government legislation. Within an individual business traceability can be quite simple to implement, however, in a global trading market, traceability of the entire supply chain, including logistics is extremely complex. For this reason IT solutions such as TraceTracker have been developed which not only provide electronic solutions for complete traceability but also allow products to be tracked at any point in the supply chain.

  5. Automated Methodologies for the Design of Flow Diagrams for Development and Maintenance Activities

    NASA Astrophysics Data System (ADS)

    Shivanand M., Handigund; Shweta, Bhat

    The Software Requirements Specification (SRS) of the organization is a text document prepared by strategic management incorporating the requirements of the organization. These requirements of ongoing business/ project development process involve the software tools, the hardware devices, the manual procedures, the application programs and the communication commands. These components are appropriately ordered for achieving the mission of the concerned process both in the project development and the ongoing business processes, in different flow diagrams viz. activity chart, workflow diagram, activity diagram, component diagram and deployment diagram. This paper proposes two generic, automatic methodologies for the design of various flow diagrams of (i) project development activities, (ii) ongoing business process. The methodologies also resolve the ensuing deadlocks in the flow diagrams and determine the critical paths for the activity chart. Though both methodologies are independent, each complements other in authenticating its correctness and completeness.

  6. 75 FR 24569 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... input on the new framework being developed for animal disease traceability. Additional meetings are...

  7. 75 FR 33576 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-14

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... the new framework being developed for animal disease traceability. The meetings are being organized by...

  8. 75 FR 47769 - Animal Traceability; Public Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-09

    ... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2010-0050] Animal Traceability; Public Meetings AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... the new framework being developed for animal disease traceability. The meetings are being organized by...

  9. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  10. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  11. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  12. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  13. 40 CFR 1065.301 - Overview and general provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... judgment. (d) Use NIST-traceable standards to the tolerances we specify for calibrations and verifications. Where we specify the need to use NIST-traceable standards, you may alternatively ask for our approval to use international standards that are not NIST-traceable. ...

  14. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  15. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  16. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  17. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  18. 40 CFR 1065.315 - Pressure, temperature, and dewpoint calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quantities that are NIST-traceable within 0.5% uncertainty. (2) Temperature. We recommend digital dry-block... errors. We recommend using calibration reference quantities that are NIST-traceable within 0.5... NIST-traceable simulator that is independently calibrated and, as appropriate, cold-junction...

  19. Traceability of radiation protection instruments

    NASA Astrophysics Data System (ADS)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  20. Proceedings of the November 2011 Traceability Research Summit: this report is the third in a series on Traceability Summits sponsored by IFT beginning in July 2011.

    PubMed

    Hickey, Caitlin; Bhatt, Tejas

    2013-12-01

    Fifty thought leaders in the area of food traceability met for a 3rd time to discuss methodologies and finalize the principles that define their vision for traceability. Participants in the summit included representatives from industry, trade associations, government, academia, consumer groups, and more. One main focus of this summit included a discussion on the current regulations and voluntary initiatives in place regarding traceability. Overall, it was recognized that the recommendations from this summit group would be more specific and stringent in comparison to these current regulations and initiatives. The participants sought to be leaders in the traceability arena, with their recommendations leading the industry to optimal traceability systems and methods. Participants agreed on many principles for their vision of traceability, emphasizing the importance of access to traceability data. They discussed having industry be asked for "basic" tracing data prior to the need for a large-scale investigation, having standards for sharing data, and having the data in electronic form. Participants foresaw the importance of capturing data electronically in the future, although they recognized that many firms do not currently do this. The group also saw a need for a transition period to implement changes, and to provide implementation training and resource aid to small businesses. Summit participants discussed specific definitions and examples for key data elements and critical tracking events that could be used by industry to capture tracing data at specific points within the supply chain. Overall, participants refined the goals of the summit group and started to identify specific ways to achieve those goals. © 2013 Institute of Food Technologists®

  1. A PetriNet-Based Approach for Supporting Traceability in Cyber-Physical Manufacturing Systems

    PubMed Central

    Huang, Jiwei; Zhu, Yeping; Cheng, Bo; Lin, Chuang; Chen, Junliang

    2016-01-01

    With the growing popularity of complex dynamic activities in manufacturing processes, traceability of the entire life of every product has drawn significant attention especially for food, clinical materials, and similar items. This paper studies the traceability issue in cyber-physical manufacturing systems from a theoretical viewpoint. Petri net models are generalized for formulating dynamic manufacturing processes, based on which a detailed approach for enabling traceability analysis is presented. Models as well as algorithms are carefully designed, which can trace back the lifecycle of a possibly contaminated item. A practical prototype system for supporting traceability is designed, and a real-life case study of a quality control system for bee products is presented to validate the effectiveness of the approach. PMID:26999141

  2. Importance of Requirements Analysis & Traceability to Improve Software Quality and Reduce Cost and Risk

    NASA Technical Reports Server (NTRS)

    Kapoor, Manju M.; Mehta, Manju

    2010-01-01

    The goal of this paper is to emphasize the importance of developing complete and unambiguous requirements early in the project cycle (prior to Preliminary Design Phase). Having a complete set of requirements early in the project cycle allows sufficient time to generate a traceability matrix. Requirements traceability and analysis are the key elements in improving verification and validation process, and thus overall software quality. Traceability can be most beneficial when the system changes. If changes are made to high-level requirements it implies that low-level requirements need to be modified. Traceability ensures that requirements are appropriately and efficiently verified at various levels whereas analysis ensures that a rightly interpreted set of requirements is produced.

  3. A PetriNet-Based Approach for Supporting Traceability in Cyber-Physical Manufacturing Systems.

    PubMed

    Huang, Jiwei; Zhu, Yeping; Cheng, Bo; Lin, Chuang; Chen, Junliang

    2016-03-17

    With the growing popularity of complex dynamic activities in manufacturing processes, traceability of the entire life of every product has drawn significant attention especially for food, clinical materials, and similar items. This paper studies the traceability issue in cyber-physical manufacturing systems from a theoretical viewpoint. Petri net models are generalized for formulating dynamic manufacturing processes, based on which a detailed approach for enabling traceability analysis is presented. Models as well as algorithms are carefully designed, which can trace back the lifecycle of a possibly contaminated item. A practical prototype system for supporting traceability is designed, and a real-life case study of a quality control system for bee products is presented to validate the effectiveness of the approach.

  4. Proceedings of a Meeting on Traceability for Ionizing Radiation Measurements

    NASA Astrophysics Data System (ADS)

    Heaton, H. T., II

    1982-02-01

    General concepts for traceability were presented from several perspectives. The national standards for radiation dosimetry, radioactivity measurements, and neutron measurements were described. Specific programs for achieving traceability to the national standards for radiation measurements in medical, occupational, and environmental applications were summarized.

  5. Whole-chain traceability, is it possible to trace your hamburger to a particular steer, a U. S. perspective.

    PubMed

    Crandall, Philip G; O'Bryan, Corliss A; Babu, Dinesh; Jarvis, Nathan; Davis, Mike L; Buser, Michael; Adam, Brian; Marcy, John; Ricke, Steven C

    2013-10-01

    Traceability through the entire food supply chain from conception to consumption is a pressing need for the food industry, consumers and government regulators. A robust, whole-chain traceability system is needed that will effectively address food quality, food safety and food defense issues by providing real-time, transparent and reliable information from beef production through slaughter and distribution to the consumer. Traceability is an expanding part of the food safety continuum that minimizes the risk of foodborne diseases, assures quality and cold-chain integrity. Traceability can be a positive competitive marketing edge for beef producers who can verify specific quality attributes such as humane production or grass fed or Certified Organic. In this review we address the benefits as well as the remaining issues for whole-chain traceability in the beef industry, with particular focus on ground beef for the markets in the United States. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Making traceability work across the entire food supply chain.

    PubMed

    Bhatt, Tejas; Buckley, Greg; McEntire, Jennifer C; Lothian, Paul; Sterling, Brian; Hickey, Caitlin

    2013-12-01

    The Institute of Food Technologists held Traceability Research Summits on July 14, August 22, and November 1, 2011, to address how to meet the growing requirement for agriculture and food traceability. Each meeting had a group of about 50 individuals who came from food companies, trade associations, local, state, and federal governments, 3rd-party traceability solution providers, not-for-profit corporations, consultants, and consumer groups. They discussed and deliberated the objectives of traceability and the means to develop product tracing in the food system. A total of 70 people participated in the 3 summits. These individuals were invited to participate in a small workgroup responsible for considering the details related to product tracing and presenting draft concepts to the larger group on November 1, 2011, in Chicago. During this meeting, the larger assembly further refined the concepts and came to an agreement on the basic principles and overall design of the desired approach to traceability. © 2013 Institute of Food Technologists®

  7. Progress of Icelandic Lava Flows Charted by NASA EO-1 Spacecraft

    NASA Image and Video Library

    2014-09-09

    On the night of Sept. 6, 2014 NASA Earth Observing 1 EO-1 spacecraft observed the ongoing eruption at Holuhraun, Iceland. Partially covered by clouds, this scene shows the extent of the lava flows that have been erupting.

  8. 78 FR 2039 - Traceability for Livestock Moving Interstate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... Inspection Service 9 CFR Parts 71, 77, 78, et al. Traceability for Livestock Moving Interstate; Final Rule #0..., and 86 [Docket No. APHIS-2009-0091] RIN 0579-AD24 Traceability for Livestock Moving Interstate AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Final rule. SUMMARY: We are amending the...

  9. 76 FR 50081 - Traceability for Livestock Moving Interstate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ... Inspection Service 9 CFR Parts 71, 77, 78, et al. Traceability for Livestock Moving Interstate; Proposed Rule... 90 [Docket No. APHIS-2009-0091] RIN 0579-AD24 Traceability for Livestock Moving Interstate AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Proposed rule. SUMMARY: We are proposing to...

  10. Cattle traceability system in Japan for bovine spongiform encephalopathy.

    PubMed

    Sugiura, Katsuaki; Onodera, Takashi

    2008-01-01

    To promote consumer confidence in the safety of beef and to ensure the proper implementation of eradication measures against bovine spongiform encephalopathy (BSE), the Cattle Traceability Law was approved by the Diet in June 2003 and a cattle traceability system has been in operation in Japan since December 2003. The system enables tracing the cohort and offspring animals of a BSE case within 24 h of its detection. The traceability database system also provides distributors, restaurants and consumers with information on the cattle from which the beef that they sell, serve and consume, originate.

  11. How to obtain traceability on optical radiation measurements?

    NASA Astrophysics Data System (ADS)

    Matamoros García, Carlos H.

    2006-02-01

    Traceability to national standards provides confidence in measurements results, granting a guaranty when carrying out governmental rules and when demonstrating conformity with quality requirements such as ISO 9000 or ISO/IEC 17025 (and the Mexican equivalent standards). The appropriate traceability contributes with confidence of the quality of products or services. This paper presents different ways to obtain traceability in Mexico for the optical radiation measurements, mentioning some applications, and highlighting the necessity of having traceability to the appropriate units of the SI. Additionally it present the national standards maintained by Centro Nacional de Metrologia (CENAM), the national metrology institute in Mexico, that give the technical support to Mexican measurements in this field and the international recognition that the personal of the Optics and Radiometry Division had gained in 10 years of development.

  12. Traceability of Boletaceae mushrooms using data fusion of UV-visible and FTIR combined with chemometrics methods.

    PubMed

    Yao, Sen; Li, Tao; Liu, HongGao; Li, JieQing; Wang, YuanZhong

    2018-04-01

    Boletaceae mushrooms are wild-grown edible mushrooms that have high nutrition, delicious flavor and large economic value distributing in Yunnan Province, China. Traceability is important for the authentication and quality assessment of Boletaceae mushrooms. In this study, UV-visible and Fourier transform infrared (FTIR) spectroscopies were applied for traceability of 247 Boletaceae mushroom samples in combination with chemometrics. Compared with a single spectroscopy technique, data fusion strategy can obviously improve the classification performance in partial least square discriminant analysis (PLS-DA) and grid-search support vector machine (GS-SVM) models, for both species and geographical origin traceability. In addition, PLS-DA and GS-SVM models can provide 100.00% accuracy for species traceability and have reliable evaluation parameters. For geographical origin traceability, the accuracy of prediction in the PLS-DA model by data fusion was just 64.63%, but the GS-SVM model based on data fusion was 100.00%. The results demonstrated that the data fusion strategy of UV-visible and FTIR combined with GS-SVM could provide a higher synergic effect for traceability of Boletaceae mushrooms and have a good generalization ability for the comprehensive quality control and evaluation of similar foods. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  13. Traceability in hardness measurements: from the definition to industry

    NASA Astrophysics Data System (ADS)

    Germak, Alessandro; Herrmann, Konrad; Low, Samuel

    2010-04-01

    The measurement of hardness has been and continues to be of significant importance to many of the world's manufacturing industries. Conventional hardness testing is the most commonly used method for acceptance testing and production quality control of metals and metallic products. Instrumented indentation is one of the few techniques available for obtaining various property values for coatings and electronic products in the micrometre and nanometre dimensional scales. For these industries to be successful, it is critical that measurements made by suppliers and customers agree within some practical limits. To help assure this measurement agreement, a traceability chain for hardness measurement traceability from the hardness definition to industry has developed and evolved over the past 100 years, but its development has been complicated. A hardness measurement value not only requires traceability of force, length and time measurements but also requires traceability of the hardness values measured by the hardness machine. These multiple traceability paths are needed because a hardness measurement is affected by other influence parameters that are often difficult to identify, quantify and correct. This paper describes the current situation of hardness measurement traceability that exists for the conventional hardness methods (i.e. Rockwell, Brinell, Vickers and Knoop hardness) and for special-application hardness and indentation methods (i.e. elastomer, dynamic, portables and instrumented indentation).

  14. MO-A-BRB-03: Integration Issues in Electronic Charting for External Beam Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutlief, S.

    2015-06-15

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiationmore » therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.« less

  15. MO-A-BRB-02: Considerations and Issues in Electronic Charting for Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, S.

    2015-06-15

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiationmore » therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.« less

  16. A full three dimensional Navier-Stokes numerical simulation of flow field inside a power plant Kaplan turbine using some model test turbine hill chart points

    NASA Astrophysics Data System (ADS)

    Hosseinalipour, S. M.; Raja, A.; Hajikhani, S.

    2012-06-01

    A full three dimensional Navier - Stokes numerical simulation has been performed for performance analysis of a Kaplan turbine which is installed in one of the Irans south dams. No simplifications have been enforced in the simulation. The numerical results have been evaluated using some integral parameters such as the turbine efficiency via comparing the results with existing experimental data from the prototype Hill chart. In part of this study the numerical simulations were performed in order to calculate the prototype turbine efficiencies in some specific points which comes from the scaling up of the model efficiency that are available in the model experimental Hill chart. The results are very promising which shows the good ability of the numerical techniques for resolving the flow characteristics in these kind of complex geometries. A parametric study regarding the evaluation of turbine performance in three different runner angles of the prototype is also performed and the results are cited in this paper.

  17. Breed traceability of buffalo meat using microsatellite genotyping technique.

    PubMed

    Kannur, Bheemashankar H; Fairoze, Md Nadeem; Girish, P S; Karabasanavar, Nagappa; Rudresh, B H

    2017-02-01

    Although buffalo has emerged as a major meat producing animal in Asia, major research on breed traceability has so far been focused on cattle (beef). This research gap on buffalo breed traceability has impelled development and validation of buffalo breed traceability using a set of eight microsatellite (STR) markers in seven Indian buffalo breeds (Bhadawari, Jaffaarabadi, Murrah, Mehsana, Nagpuri, Pandharpuri and Surti). Probability of sharing same profile by two individuals at a specific locus was computed considering different STR numbers, allele pooling in breed and population. Match probabilities per breed were considered and six most polymorphic loci were genotyped. Out of eight microsatellite markers studied, markers CSSMO47, DRB3 and CSSM060 were found most polymorphic. Developed technique was validated with known and unknown, blood and meat samples; wherein, samples were genetically traced in 24 out of 25 samples tested. Results of this study showed potential applications of the methodology and encourage other researchers to address the problem of buffalo traceability so as to create a world-wide archive of breed specific genotypes. This work is the first report of breed traceability of buffalo meat utilizing microsatellite genotyping technique.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mechalakos, J.

    The process of converting to an electronic chart for radiation therapy can be daunting. It requires a dedicated committee to first research and choose appropriate software, to review the entire documentation policy and flow of the clinic, to convert this system to electronic form or if necessary, redesign the system to more easily conform to the electronic process. Those making the conversion and those who already use electronic charting would benefit from the shared experience of those who have been through the process in the past. Therefore TG262 was convened to provide guidance on electronic charting for external beam radiationmore » therapy and brachytherapy. This course will present the results of an internal survey of task group members on EMR practices in External Beam Radiation Therapy as well as discuss important issues in EMR development and structure for both EBRT and brachytherapy. Learning Objectives: Be familiarized with common practices and pitfalls in development and maintenance of an electronic chart in Radiation Oncology Be familiarized with important issues related to electronic charting in External Beam Radiation Therapy Be familiarized with important issues related to electronic charting in Brachytherapy.« less

  19. Current Barriers to Large-scale Interoperability of Traceability Technology in the Seafood Sector.

    PubMed

    Hardt, Marah J; Flett, Keith; Howell, Colleen J

    2017-08-01

    Interoperability is a critical component of full-chain digital traceability, but is almost nonexistent in the seafood industry. Using both quantitative and qualitative methodology, this study explores the barriers impeding progress toward large-scale interoperability among digital traceability systems in the seafood sector from the perspectives of seafood companies, technology vendors, and supply chains as a whole. We highlight lessons from recent research and field work focused on implementing traceability across full supply chains and make some recommendations for next steps in terms of overcoming challenges and scaling current efforts. © 2017 Institute of Food Technologists®.

  20. A Structural Weight Estimation Program (SWEEP) for Aircraft. Volume 6 - Wing and Empennage Module. Appendix A: General Information for Module Flow Charts and Listings. Appendix B: Program Flow Charts, Overlays (8,0), (14,0), (15,0), (16,0) and (17,0)

    DTIC Science & Technology

    1974-06-01

    reimi /oifi I mew oo n ni I • I t»M • »’ - (I/O.. -iISIII »7. . ISIll • »I/ISM • ^■>l niKii • mi i Wi’iOui...flll>»tlllll"r A ’ torn». • rami nm • reiMi ni»i • ocm .. • cioie • i it CKDIII • nsiiii 1 IMIBl • TCIII TWllTI ■ TCm miai • «ein

  1. A hierarchical modeling methodology for the definition and selection of requirements

    NASA Astrophysics Data System (ADS)

    Dufresne, Stephane

    This dissertation describes the development of a requirements analysis methodology that takes into account the concept of operations and the hierarchical decomposition of aerospace systems. At the core of the methodology, the Analytic Network Process (ANP) is used to ensure the traceability between the qualitative and quantitative information present in the hierarchical model. The proposed methodology is implemented to the requirements definition of a hurricane tracker Unmanned Aerial Vehicle. Three research objectives are identified in this work; (1) improve the requirements mapping process by matching the stakeholder expectations with the concept of operations, systems and available resources; (2) reduce the epistemic uncertainty surrounding the requirements and requirements mapping; and (3) improve the requirements down-selection process by taking into account the level of importance of the criteria and the available resources. Several challenges are associated with the identification and definition of requirements. The complexity of the system implies that a large number of requirements are needed to define the systems. These requirements are defined early in the conceptual design, where the level of knowledge is relatively low and the level of uncertainty is large. The proposed methodology intends to increase the level of knowledge and reduce the level of uncertainty by guiding the design team through a structured process. To address these challenges, a new methodology is created to flow-down the requirements from the stakeholder expectations to the systems alternatives. A taxonomy of requirements is created to classify the information gathered during the problem definition. Subsequently, the operational and systems functions and measures of effectiveness are integrated to a hierarchical model to allow the traceability of the information. Monte Carlo methods are used to evaluate the variations of the hierarchical model elements and consequently reduce the epistemic uncertainty. The proposed methodology is applied to the design of a hurricane tracker Unmanned Aerial Vehicles to demonstrate the origin and impact of requirements on the concept of operations and systems alternatives. This research demonstrates that the hierarchical modeling methodology provides a traceable flow-down of the requirements from the problem definition to the systems alternatives phases of conceptual design.

  2. [Establishment of traceability system of Chinese medicinal materials' quality].

    PubMed

    Qi, Yao-dong; Gao, Shi-man; Liu, Hai-tao; Li, Xi-wen; Wei, Jian-he; Zhang, Ben-gang; Sun, Xiao-bo; Xiao, Pei-gen

    2015-12-01

    The quality of Chinese medicinal materials relates greatly to the clinical curative effect and security. In order to ensure the quality and safety of Chinese medicinal materials, a systematic and operable traceability system needs to be established. It can realize the whole process of quality and safety management of Chinese medicinal materials "from production to consumption" through recording and inquiring information and recalling defective products, which is an important direction for the future development of traditional Chinese medicine. But it is still at the exploration and trial stage. In this paper, a framework of Chinese medicinal materials' quality and safety traceability system was established on the basis of the domestic and international experience about the construction of food and agricultural products traceability systems. The relationship between traceability system of Chinese medicinal materials' quality and GAP, GMP, GSP was analyzed, and the possible problems and the corresponding solutions were discussed.

  3. Toward fish and seafood traceability: anchovy species determination in fish products by molecular markers and support through a public domain database.

    PubMed

    Jérôme, Marc; Martinsohn, Jann Thorsten; Ortega, Delphine; Carreau, Philippe; Verrez-Bagnis, Véronique; Mouchel, Olivier

    2008-05-28

    Traceability in the fish food sector plays an increasingly important role for consumer protection and confidence building. This is reflected by the introduction of legislation and rules covering traceability on national and international levels. Although traceability through labeling is well established and supported by respective regulations, monitoring and enforcement of these rules are still hampered by the lack of efficient diagnostic tools. We describe protocols using a direct sequencing method based on 212-274-bp diagnostic sequences derived from species-specific mitochondria DNA cytochrome b, 16S rRNA, and cytochrome oxidase subunit I sequences which can efficiently be applied to unambiguously determine even closely related fish species in processed food products labeled "anchovy". Traceability of anchovy-labeled products is supported by the public online database AnchovyID ( http://anchovyid.jrc.ec.europa.eu), which provided data obtained during our study and tools for analytical purposes.

  4. TOPICAL REVIEW: Advances in traceable nanometrology at the National Physical Laboratory†Advances in traceable nanometrology at the National Physical Laboratory

    NASA Astrophysics Data System (ADS)

    Leach, Richard; Haycocks, Jane; Jackson, Keith; Lewis, Andrew; Oldfield, Simon; Yacoot, Andrew

    2001-03-01

    The only difference between nanotechnology and many other fields of science or engineering is that of size. Control in manufacturing at the nanometre scale still requires accurate and traceable measurements whether one is attempting to machine optical quality glass or write one's company name in single atoms. A number of instruments have been developed at the National Physical Laboratory that address the measurement requirements of the nanotechnology community and provide traceability to the definition of the metre. The instruments discussed in this paper are an atomic force microscope and a surface texture measuring instrument with traceable metrology in all their operational axes, a combined optical and x-ray interferometer system that can be used to calibrate displacement transducers to subnanometre accuracy and a co-ordinate measuring machine with a working volume of (50 mm)3 and 50 nm volumetric accuracy.

  5. Value-Based Requirements Traceability: Lessons Learned

    NASA Astrophysics Data System (ADS)

    Egyed, Alexander; Grünbacher, Paul; Heindl, Matthias; Biffl, Stefan

    Traceability from requirements to code is mandated by numerous software development standards. These standards, however, are not explicit about the appropriate level of quality of trace links. From a technical perspective, trace quality should meet the needs of the intended trace utilizations. Unfortunately, long-term trace utilizations are typically unknown at the time of trace acquisition which represents a dilemma for many companies. This chapter suggests ways to balance the cost and benefits of requirements traceability. We present data from three case studies demonstrating that trace acquisition requires broad coverage but can tolerate imprecision. With this trade-off our lessons learned suggest a traceability strategy that (1) provides trace links more quickly, (2) refines trace links according to user-defined value considerations, and (3) supports the later refinement of trace links in case the initial value consideration has changed over time. The scope of our work considers the entire life cycle of traceability instead of just the creation of trace links.

  6. Issues to be Considered in the Evaluation of Technical Proposals from the Ada (Trademark) Language Perspective.

    DTIC Science & Technology

    1985-06-10

    flowcharts - hierarchical charts - data flow diagrams - finite state diagrams - control flow diagrams - decision tables/trees - entity-relationship...and beginners ; for example, is prompting via menus provided for beginners and single keystroke capability provided for experienced users? 2-13 - input

  7. On the traceability of gaseous reference materials

    NASA Astrophysics Data System (ADS)

    Brown, Richard J. C.; Brewer, Paul J.; Harris, Peter M.; Davidson, Stuart; van der Veen, Adriaan M. H.; Ent, Hugo

    2017-06-01

    The complex and multi-parameter nature of chemical composition measurement means that establishing traceability is a challenging task. As a result incorrect interpretations about the origin of the metrological traceability of chemical measurement results can occur. This discussion paper examines why this is the case by scrutinising the peculiarities of the gas metrology area. It considers in particular: primary methods, dissemination of metrological traceability and the role of documentary standards and accreditation bodies in promulgating best practice. There is also a discussion of documentary standards relevant to the NMI and reference material producer community which need clarification, and the impact which key stakeholders in the quality infrastructure can bring to these issues.

  8. Capital Budgeting Decisions with Post-Audit Information

    DTIC Science & Technology

    1990-06-08

    estimates that were used during project selection. In similar fashion, this research introduces the equivalent sample size concept that permits the... equivalent sample size is extended to include the user’s prior beliefs. 4. For a management tool, the concepts for Cash Flow Control Charts are...Acoxxting Research , vol. 7, no. 2, Autumn 1969, pp. 215-244. [9] Gaynor, Edwin W., "Use of Control Charts in Cost Control ", National Association of Cost

  9. 14 CFR 93.57 - General rules: All segments.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Area shall conform to the flow of traffic depicted on the appropriate aeronautical charts. (c) Each person operating a helicopter shall operate it in a manner so as to avoid the flow of airplanes. (d...) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area...

  10. 14 CFR 93.57 - General rules: All segments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Area shall conform to the flow of traffic depicted on the appropriate aeronautical charts. (c) Each person operating a helicopter shall operate it in a manner so as to avoid the flow of airplanes. (d...) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area...

  11. 14 CFR 93.57 - General rules: All segments.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Area shall conform to the flow of traffic depicted on the appropriate aeronautical charts. (c) Each person operating a helicopter shall operate it in a manner so as to avoid the flow of airplanes. (d...) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area...

  12. 14 CFR 93.57 - General rules: All segments.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Area shall conform to the flow of traffic depicted on the appropriate aeronautical charts. (c) Each person operating a helicopter shall operate it in a manner so as to avoid the flow of airplanes. (d...) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area...

  13. 14 CFR 93.57 - General rules: All segments.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Area shall conform to the flow of traffic depicted on the appropriate aeronautical charts. (c) Each person operating a helicopter shall operate it in a manner so as to avoid the flow of airplanes. (d...) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal Area...

  14. A Pulsatile Cardiovascular Computer Model for Teaching Heart-Blood Vessel Interaction.

    ERIC Educational Resources Information Center

    Campbell, Kenneth; And Others

    1982-01-01

    Describes a model which gives realistic predictions of pulsatile pressure, flow, and volume events in the cardiovascular system. Includes computer oriented laboratory exercises for veterinary and graduate students; equations of the dynamic and algebraic models; and a flow chart for the cardiovascular teaching program. (JN)

  15. A general representation for axial-flow fans and turbines

    NASA Technical Reports Server (NTRS)

    Perl, W; Tucker, M

    1945-01-01

    A general representation of fan and turbine arrangements on a single classification chart is presented that is made possible by a particular definition of the stage of an axial-flow fan or turbine. Several unconventional fan and turbine arrangements are indicated and the applications of these arrangements are discussed.

  16. Construction of Traceability System for Quality Safety of Cereal and Oil Products

    NASA Astrophysics Data System (ADS)

    Zheng, Huoguo; Liu, Shihong; Meng, Hong; Hu, Haiyan

    After several significant food safety incident, global food industry and governments in many countries are putting increasing emphasis on establishment of food traceability systems. Food traceability has become an effective way in food quality and safety management. The traceability system for quality safety of cereal and oil products was designed and implemented with HACCP and FMECA method, encoding, information processing, and hardware R&D technology etc, according to the whole supply chain of cereal and oil products. Results indicated that the system provide not only the management in origin, processing, circulating and consuming for enterprise, but also tracing service for customers and supervisor by means of telephone, internet, SMS, touch machine and mobile terminal.

  17. Efficacy of predictive wavefront control for compensating aero-optical aberrations

    NASA Astrophysics Data System (ADS)

    Goorskey, David J.; Schmidt, Jason; Whiteley, Matthew R.

    2013-07-01

    Imaging and laser beam propagation from airborne platforms are degraded by dynamic aberrations due to air flow around the aircraft, aero-mechanical distortions and jitter, and free atmospheric turbulence. For certain applications, like dim-object imaging, free-space optical communications, and laser weapons, adaptive optics (AO) is necessary to compensate for the aberrations in real time. Aero-optical flow is a particularly interesting source of aberrations whose flowing structures can be exploited by adaptive and predictive AO controllers, thereby realizing significant performance gains. We analyze dynamic aero-optical wavefronts to determine the pointing angles at which predictive wavefront control is more effective than conventional, fixed-gain, linear-filter control. It was found that properties of the spatial decompositions and temporal statistics of the wavefronts are directly traceable to specific features in the air flow. Furthermore, the aero-optical wavefront aberrations at the side- and aft-looking angles were the most severe, but they also benefited the most from predictive AO.

  18. Comparative analysis for evaluating the traceability of interventional devices using blood vessel phantom models made of PVA-H or silicone.

    PubMed

    Yu, Chang-Ho; Kwon, Tae-Kyu; Park, Chan Hee; Ohta, Makoto; Kim, Sung Hoon

    2015-01-01

    In this paper, we investigated the parameters with effective traceability to assess the mechanical properties of interventional devices. In our evaluation system, a box-shaped poly (vinyl alcohol) hydrogel (PVA-H) and silicone were prepared with realistic geometry, and the measurement and evaluation of traceability were carried out on devices using load hand force. The phantom models had a total of five curve pathways to reach the aneurysm sac. Traceability depends on the performance of the interventional devices in order to pass through the curved part of the model simulation track. The traceability of the guide wire was found to be much better than that of the balloon and stent loading catheter, as it reached the aneurysm sac in both phantom models. Observation using the video record is another advantage of our system, because the high transparency of the materials with silicone and PVA-H can allow visualization of the inside of an artery.

  19. A Catalog of NASA Special Publications

    DTIC Science & Technology

    1981-01-01

    Properties and Mollier Perfect Carbon Dioxide and Nitrogen Chart for Hydrogen From 300 K to Mixtures 20 000 K Wt’. P. Peterson R. F. Kubin, L. L. Presley...human per- Avail NTIS 1964 formance. NASA SP-3006 Equilibrium Thermodynamic Properties N73-15091 938 pp of Carbon Dioxide Avail GPO 1973 H. E. Bailey...N64-25017 4 27 pp Avail GPO 1964 39 Charts for Equilibrium Flow Properties Equilibrium Thermodynamic Properties of Carbon Dioxide in Hypervelocity of

  20. Depreciation Accounting in the Uniform Chart of Accounts.

    DTIC Science & Technology

    1982-12-01

    footage of building occupied. Reason( s ) for Compute full cost of Rate setting, cash accounting for patient care flow generation and fund- depreciation ing... Horngren , Charles T., Cost Accounting ; A Managerial Emphasis, Prentice-Hall Inc., 1972. 32. Sawyer, Lawrence B., The Practice of Modern Internal Auditing...Awd ubtlft) S . TYPE or RE PORT a PE*IoO CovIERWO Master’s Thesis; Depreciation Accounting in the Uniform Dembr18 Chart of Accounts .PSOiwON.EORlumm

  1. Tracking Online Trails

    NASA Astrophysics Data System (ADS)

    Qi, Man; Edgar-Nevill, Denis; Wang, Yongquan; Xu, Rongsheng

    Traceability is a key to the investigation of the internet criminal and a cornerstone of internet research. It is impossible to prevent all internet misuse but may be possible to identify and trace the users, and then take appropriate action. This paper presents the value of traceability within the email/-newsposting utilities, the technologies being using to hide identities, the difficulties in locating the traceable data and the challenges in tracking online trails.

  2. Management traceability information system for the food supply chain

    NASA Astrophysics Data System (ADS)

    Bendriss, S.; Benabdelhafid, A.; Boukachour, J.

    2008-06-01

    For a long time, the traceability was applied only for management reasons, but with the advent of new communication and information technologies more and more used in the logistic medium, the notion of the traceability became new extensive to meet the new market needs in term of information by ensuring accessibility the data characteristic or been dependent on the product throughout its life cycle. On the basis of this postulate, we tried to raise some questions of research, beginning by the presentation of the progress achieved, assumptions and objective relating to the traceability, in the second time we mentioned principal work by showing how evolved the scientific question especially the information systems integrating the traceability were developed very little in the literature. Based on what was developed in the first part, we present our generic modeling approach of communicating product "smart object", able to take into account the various essential elements for its traceability: the product in its various states, various operations carried out on the product, resources used, its localization, and interactions between the product and its environment carried out on the basis of whole of service. In order to validate our generic modeling, a case of study representing an application in a context of food industry is presented.

  3. Tissue allograft coding and traceability in USM Tissue Bank, Malaysia.

    PubMed

    Sheikh Ab Hamid, Suzina; Abd Rahman, Muhamad Nor Firdaus

    2010-11-01

    In Malaysia, tissue banking activities began in Universiti Sains Malaysia (USM) Tissue Bank in early 1990s. Since then a few other bone banks have been set up in other government hospitals and institutions. However, these banks are not governed by the national authority. In addition there is no requirement set by the national regulatory authority on coding and traceability for donated human tissues for transplantation. Hence, USM Tissue Bank has taken the initiatives to adopt a system that enables the traceability of tissues between the donor, the processed tissue and the recipient based on other international standards for tissue banks. The traceability trail has been effective and the bank is certified compliance to the international standard ISO 9001:2008.

  4. TF4SM: A Framework for Developing Traceability Solutions in Small Manufacturing Companies

    PubMed Central

    Bordel Sánchez, Borja; Alcarria, Ramón; Martín, Diego; Robles, Tomás

    2015-01-01

    Nowadays, manufacturing processes have become highly complex. Besides, more and more, governmental institutions require companies to implement systems to trace a product’s life (especially for foods, clinical materials or similar items). In this paper, we propose a new framework, based on cyber-physical systems, for developing traceability systems in small manufacturing companies (which because of their size cannot implement other commercial products). We propose a general theoretical framework, study the requirements of these companies in relation to traceability systems, propose a reference architecture based on both previous elements and build the first minimum functional prototype, to compare our solution to a traditional tag-based traceability system. Results show that our system reduces the number of inefficiencies and reaction time. PMID:26610509

  5. TF4SM: A Framework for Developing Traceability Solutions in Small Manufacturing Companies.

    PubMed

    Bordel Sánchez, Borja; Alcarria, Ramón; Martín, Diego; Robles, Tomás

    2015-11-20

    Nowadays, manufacturing processes have become highly complex. Besides, more and more, governmental institutions require companies to implement systems to trace a product's life (especially for foods, clinical materials or similar items). In this paper, we propose a new framework, based on cyber-physical systems, for developing traceability systems in small manufacturing companies (which because of their size cannot implement other commercial products). We propose a general theoretical framework, study the requirements of these companies in relation to traceability systems, propose a reference architecture based on both previous elements and build the first minimum functional prototype, to compare our solution to a traditional tag-based traceability system. Results show that our system reduces the number of inefficiencies and reaction time.

  6. [3-channels data acquisition system based on single-chip-microcomputer used in the measurement of coronary sinus blood flow].

    PubMed

    Li, Z; Fan, Y; Chen, G

    1999-07-01

    The coronary sinus blood flow can be figured out, which based on the principle of thermodilution, so long as gets the temperature of blood, indicator and mixture of blood and indicator respectively. This system is a smart slave module with single-chip-microcomputer. The structure and principles of hardware and the flow chart of software are described in detail.

  7. Equations and charts for the rapid estimation of hinge-moment and effectiveness parameters for trailing-edge controls having leading and trailing edges swept ahead of the Mach lines

    NASA Technical Reports Server (NTRS)

    Goin, Kennith L

    1951-01-01

    Existing conical-flow solutions have been used to calculate the hinge-moments and effectiveness parameters of trailing-edge controls having leading and trailing edges swept ahead of the Mach lines and having streamwise root and tip chords. Equations and detailed charts are presented for the rapid estimation of these parameters. Also included is an approximate method by which these parameters may be corrected for airfoil-section thickness.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gröbner, Julian; Reda, Ibrahim; Wacker, Stefan

    Atmospheric longwave irradiance is currently not metrologically traceable. Traceability requires formal comparisons in the framwork of the CIPM MRA. A task team on Radiation has been created by the WMO to address these issues.

  9. A methodology for post-EIS (environmental impact statement) monitoring

    USGS Publications Warehouse

    Marcus, Linda Graves

    1979-01-01

    A methodology for monitoring the impacts predicted in environmental impact statements (EIS's) was developed using the EIS on phosphate development in southeastern Idaho as a case study. A monitoring system based on this methodology: (1) coordinates a comprehensive, intergovernmental monitoring effort; (2) documents the major impacts that result, thereby improving the accuracy of impact predictions in future EIS's; (3) helps agencies control impacts by warning them when critical impact levels are reached and by providing feedback on the success of mitigating measures; and (4) limits monitoring data to the essential information that agencies need to carry out their regulatory and environmental protection responsibilities. The methodology is presented as flow charts accompanied by tables that describe the objectives, tasks, and products for each work element in the flow chart.

  10. Table and charts of equilibrium normal-shock and shock-tube properties for pure carbon dioxide with velocities from 1 to 16 km/sec

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1976-01-01

    Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves in pure CO2. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular weight ratio, isentropic exponent, velocity, and species mole fractions. Incident (moving) shock velocities are varied from 1 to 16 km/sec for a range of initial pressure of 5 N/sq m to 500 kN/sq m. The present results are applicable to shock tube flows and to freeflight conditions for a blunt body at high velocities. Working charts illustrating idealized shock tube performance with CO2 test gas and heated helium and hydrogen driver gases are also presented.

  11. Flow Field Investigations of a Simulated Weapons Cavity at Mach 3.

    DTIC Science & Technology

    1981-12-01

    AD-Alll 843 ARMO" ENGINEERING. DEVELOPMENT CENTER ARNOLD AFS TN F/9 14/2 FLOW FIELD INVESTIGATIONS OF A SIMULATED WEAPONS CAVITY AT MACN--ETC(U) DEC...TEST CHART .. AEDC-TSR-81-V37 FLOW FIELD INVESTIGATIONS OF A _____SIMULATED WEAPONS CAVITY AT MACH 3 _~W. A. Crosby Calspan Field Services, Inc...TYPE OF REPORT & PERIOD COVERED Final Report FLOW FIELD INVESTIGATIONS OF A SIMULATED WEAPONS 27 October 1981 CAVITY AT MACH 3 6. PERFORMING O1G

  12. Knowledge Representation and Communication: Imparting Current State Information Flow to CPR Stakeholders

    PubMed Central

    de la Cruz, Norberto B.; Spiece, Leslie J.

    2000-01-01

    Understanding and communicating the who, what, where, when, why, and how of the clinics and services for which the computerized patient record (CPR) will be built is an integral part of the implementation process. Formal methodologies have been developed to diagram information flow -- flow charts, state-transition diagram (STDs), data flow diagrams (DFDs). For documentation of the processes at our ambulatory CPR pilot site, flowcharting was selected as the preferred method based upon its versatility and understandability.

  13. Flight software development for the isothermal dendritic growth experiment

    NASA Technical Reports Server (NTRS)

    Levinson, Laurie H.; Winsa, Edward A.; Glicksman, Martin E.

    1989-01-01

    The Isothermal Dendritic Growth Experiment (IDGE) is a microgravity materials science experiment scheduled to fly in the cargo bay of the shuttle on the United States Microgravity Payload (USMP) carrier. The experiment will be operated by real-time control software which will not only monitor and control onboard experiment hardware, but will also communicate, via downlink data and uplink commands, with the Payload Operations Control Center (POCC) at NASA George C. Marshall Space Flight Center (MSFC). The software development approach being used to implement this system began with software functional requirements specification. This was accomplished using the Yourdon/DeMarco methodology as supplemented by the Ward/Mellor real-time extensions. The requirements specification in combination with software prototyping was then used to generate a detailed design consisting of structure charts, module prologues, and Program Design Language (PDL) specifications. This detailed design will next be used to code the software, followed finally by testing against the functional requirements. The result will be a modular real-time control software system with traceability through every phase of the development process.

  14. Flight software development for the isothermal dendritic growth experiment

    NASA Technical Reports Server (NTRS)

    Levinson, Laurie H.; Winsa, Edward A.; Glicksman, M. E.

    1990-01-01

    The Isothermal Dendritic Growth Experiment (IDGE) is a microgravity materials science experiment scheduled to fly in the cargo bay of the shuttle on the United States Microgravity Payload (USMP) carrier. The experiment will be operated by real-time control software which will not only monitor and control onboard experiment hardware, but will also communicate, via downlink data and unlink commands, with the Payload Operations Control Center (POCC) at NASA George C. Marshall Space Flight Center (MSFC). The software development approach being used to implement this system began with software functional requirements specification. This was accomplished using the Yourdon/DeMarco methodology as supplemented by the Ward/Mellor real-time extensions. The requirements specification in combination with software prototyping was then used to generate a detailed design consisting of structure charts, module prologues, and Program Design Language (PDL) specifications. This detailed design will next be used to code the software, followed finally by testing against the functional requirements. The result will be a modular real-time control software system with traceability through every phase of the development process.

  15. Traceability from a US perspective.

    PubMed

    Smith, G C; Tatum, J D; Belk, K E; Scanga, J A; Grandin, T; Sofos, J N

    2005-09-01

    Traceability of a food consists of development of "an information trail that follows the food product's physical trail". Internationally, the US is lagging behind many countries in developing traceability systems for food in general and especially for livestock, poultry and their products. The US food industry is developing, implementing and maintaining traceability systems designed to improve food supply management, facilitate traceback for food safety and quality, and differentiate and market foods with subtle or undetectable quality attributes. Traceability, for livestock, poultry and meat, in its broadest context, can, could, or will eventually be used: (1) to ascertain origin and ownership, and to deter theft and misrepresentation, of animals and meat; (2) for surveillance, control and eradication of foreign animal diseases; (3) for biosecurity protection of the national livestock population; (4) for compliance with requirements of international customers; (5) for compliance with country-of-origin labeling requirements; (6) for improvement of supply-side management, distribution/delivery systems and inventory controls; (7) to facilitate value-based marketing; (8) to facilitate value-added marketing; (9) to isolate the source and extent of quality-control and food-safety problems; and (10) to minimize product recalls and make crisis management protocols more effective. Domestically and internationally, it has now become essential that producers, packers, processors, wholesalers, exporters and retailers assure that livestock, poultry and meat are identified, that record-keeping assures traceability through all or parts of the complete life-cycle, and that, in some cases, the source, the production-practices and/or the process of generating final products, can be verified. At issue, as the US develops traceback capabilities, will be the breadth, depth and precision of its specific traceability systems.

  16. Results of Absolute Cavity Pyrgeometer and Infrared Integrating Sphere Comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M; Sengupta, Manajit; Dooraghi, Michael R

    Accurate and traceable atmospheric longwave irradiance measurements are required for understanding radiative impacts on the Earth's energy budget. The standard to which pyrgeometers are traceable is the interim World Infrared Standard Group (WISG), maintained in the Physikalisch-Meteorologisches Observatorium Davos (PMOD). The WISG consists of four pyrgeometers that were calibrated using Rolf Philipona's Absolute Sky-scanning Radiometer [1]. The Atmospheric Radiation Measurement (ARM) facility has recently adopted the WISG to maintain the traceability of the calibrations of all Eppley precision infrared radiometer (PIR) pyrgeometers. Subsequently, Julian Grobner [2] developed the infrared interferometer spectrometer and radiometer (IRIS) radiometer, and Ibrahim Reda [3] developedmore » the absolute cavity pyrgeometer (ACP). The ACP and IRIS were developed to establish a world reference for calibrating pyrgeometers with traceability to the International System of Units (SI). The two radiometers are unwindowed with negligible spectral dependence, and they are traceable to SI units through the temperature scale (ITS-90). The two instruments were compared directly to the WISG three times at PMOD and twice at the Southern Great Plains (SGP) facility to WISG-traceable pyrgeometers. The ACP and IRIS agreed within +/- 1 W/m2 to +/- 3 W/m2 in all comparisons, whereas the WISG references exhibit a 2-5 Wm2 low bias compared to the ACP/IRIS average, depending on the water vapor column, as noted in Grobner et al. [4]. Consequently, a case for changing the current WISG has been made by Grobner and Reda. However, during the five comparisons the column water vapor exceeded 8 mm. Therefore, it is recommended that more ACP and IRIS comparisons should be held under different environmental conditions and water vapor column content to better establish the traceability of these instruments to SI with established uncertainty.« less

  17. Flow visualization of a non-contact transport device by Coanda effect

    NASA Astrophysics Data System (ADS)

    Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi

    2014-08-01

    AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.

  18. Feedback systems for nontraditional medicines: a case for the signal flow diagram.

    PubMed

    Tice, B S

    1998-11-01

    The signal flow diagram is a graphic method used to represent complex data that is found in the field of biology and hence the field of medicine. The signal flow diagram is analyzed against a table of data and a flow chart of data and evaluated on the clarity and simplicity of imparting this information. The data modeled is from previous clinical studies and nontraditional medicine from Africa, China, and South America. This report is a development from previous presentations of the signal flow diagram.1-4

  19. a Review on Legal Traceability of Gnss Measurements in the Malaysian Cadastral Practice

    NASA Astrophysics Data System (ADS)

    Gill, J.; Shariff, N. S.; Omar, K. M.; Din, A. H. M.; Amin, Z. M.

    2016-09-01

    As the dependency on Global Navigation Satellite System (GNSS) in surveying has been growing over the years, the need for legal traceability of GNSS measurements has become a significant matter. In Malaysia, with the advent of the Malaysia Real-time Kinematic Network (MyRTKnet), GNSS surveying has revolutionised land survey and mapping. Correspondingly, the Department of Survey and Mapping Malaysia (DSMM) amended and published standard regulations and guidelines concerning cadastral survey, i.e., Cadastral Survey Regulations 2009, to include GNSS measurements. However, these regulations and guidelines has not comprehensively incorporated legal traceability of GNSS measurements; which is a prerequisite for cadastral surveys as it requires reliable and conclusive evidence for issues such as boundary disputes. The first objective of this paper is to review and discuss the legal traceability of GNSS measurements. Secondly, it will highlight the current practice and issues, i.e., with regard to legal traceability, within the present Malaysian cadastral regulation and guidelines, in relation to the prevalently adopted Network RTK (N-RTK) technique, GNSS instrument calibrations, and reference stations' accuracy. Lastly, a rudimentary best practice guideline for GNSS surveying in cadastral survey for Malaysia is proposed. It is expected that this paper will contribute to the implementation of a best practice guideline, which is inclusive of legal traceability of GNSS measurements, for the Malaysian cadastral practice.

  20. Bio-markers: traceability in food safety issues.

    PubMed

    Raspor, Peter

    2005-01-01

    Research and practice are focusing on development, validation and harmonization of technologies and methodologies to ensure complete traceability process throughout the food chain. The main goals are: scale-up, implementation and validation of methods in whole food chains, assurance of authenticity, validity of labelling and application of HACCP (hazard analysis and critical control point) to the entire food chain. The current review is to sum the scientific and technological basis for ensuring complete traceability. Tracing and tracking (traceability) of foods are complex processes due to the (bio)markers, technical solutions and different circumstances in different technologies which produces various foods (processed, semi-processed, or raw). Since the food is produced for human or animal consumption we need suitable markers to be stable and traceable all along the production chain. Specific biomarkers can have a function in technology and in nutrition. Such approach would make this development faster and more comprehensive and would make possible that food effect could be monitored with same set of biomarkers in consumer. This would help to develop and implement food safety standards that would be based on real physiological function of particular food component.

  1. Molecular traceability of beef from synthetic Mexican bovine breeds.

    PubMed

    Rodríguez-Ramírez, R; Arana, A; Alfonso, L; González-Córdova, A F; Torrescano, G; Guerrero Legarreta, I; Vallejo-Cordoba, B

    2011-10-06

    Traceability ensures a link between carcass, quarters or cuts of beef and the individual animal or the group of animals from which they are derived. Meat traceability is an essential tool for successful identification and recall of contaminated products from the market during a food crisis. Meat traceability is also extremely important for protection and value enhancement of good-quality brands. Molecular meat traceability would allow verification of conventional methods used for beef tracing in synthetic Mexican bovine breeds. We evaluated a set of 11 microsatellites for their ability to identify animals belonging to these synthetic breeds, Brangus and Charolais/Brahman (78 animals). Seven microsatellite markers allowed sample discrimination with a match probability, defined as the probability of finding two individuals sharing by chance the same genotypic profile, of 10(-8). The practical application of the marker set was evaluated by testing eight samples from carcasses and pieces of meat at the slaughterhouse and at the point of sale. The DNA profiles of the two samples obtained at these two different points in the production-commercialization chain always proved that they came from the same animal.

  2. The CMC/3DPNS computer program for prediction of three-dimensional, subsonic, turbulent aerodynamic juncture region flow. Volume 3: Programmers' manual

    NASA Technical Reports Server (NTRS)

    Orzechowski, J. A.

    1982-01-01

    The CMC fluid mechanics program system was developed to transmit the theoretical evolution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. A detailed view of the code from the standpoint of a computer programmer's use is presented. A system macroflow chart and detailed flow charts of several routines necessary to interact with a theoretican/user to modify the operation of this program are presented. All subroutines and details of usage, primarily for input and output routines are described. Integer and real scalars and a cross reference list denoting subroutine usage for these scalars are outlined. Entry points in dynamic storage vector IZ; the lengths of each vector accompanying the scalar definitions are described. A listing of the routines peculiar to the standard test case and a listing of the input deck and printout for this case are included.

  3. 40 CFR 161.162 - Description of production process.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS DATA REQUIREMENTS FOR REGISTRATION OF ANTIMICROBIAL PESTICIDES Product Chemistry Data Requirements...) A flow chart of the chemical equations of each intended reaction occurring at each step of the...

  4. Seafood traceability: current needs, available tools, and biotechnological challenges for origin certification.

    PubMed

    Leal, Miguel Costa; Pimentel, Tânia; Ricardo, Fernando; Rosa, Rui; Calado, Ricardo

    2015-06-01

    Market globalization and recurring food safety alerts have resulted in a growing consumer awareness of the need for food traceability. This is particularly relevant for seafood due to its perishable nature and importance as a key protein source for the population of the world. Here, we provide an overview of the current needs for seafood origin traceability, along with the limitations and challenges for its implementation. We focus on geochemical, biochemical, and molecular tools and how they should be optimized to be implemented globally and to address our societal needs. We suggest that seafood traceability is key to enforcing food safety regulations and fisheries control, combat fraud, and fulfill present and future expectations of conscientious producers, consumers, and authorities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. General Framework for Animal Food Safety Traceability Using GS1 and RFID

    NASA Astrophysics Data System (ADS)

    Cao, Weizhu; Zheng, Limin; Zhu, Hong; Wu, Ping

    GS1 is global traceability standard, which is composed by the encoding system (EAN/UCC, EPC), the data carriers identified automatically (bar codes, RFID), electronic data interchange standards (EDI, XML). RFID is a non-contact, multi-objective automatic identification technique. Tracing of source food, standardization of RFID tags, sharing of dynamic data are problems to solve urgently for recent traceability systems. The paper designed general framework for animal food safety traceability using GS1 and RFID. This framework uses RFID tags encoding with EPCglobal tag data standards. Each information server has access tier, business tier and resource tier. These servers are heterogeneous and distributed, providing user access interfaces by SOAP or HTTP protocols. For sharing dynamic data, discovery service and object name service are used to locate dynamic distributed information servers.

  6. Resource impact factor (RIF) approach to optimal use of energy resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, R.R.

    1976-10-01

    A concept called the Resource Impact Factor (RIF) is presented as a means to quantify the social value of energy resources for buildings. The flow of various raw resources from the point of extraction to the building project boundary is shown, and a flow chart indicating the decision making process is given. (PMA)

  7. Space bioreactor: Design/process flow

    NASA Technical Reports Server (NTRS)

    Cross, John H.

    1987-01-01

    The design of the space bioreactor stems from three considerations. First, and foremost, it must sustain cells in microgravity. Closely related is the ability to take advantage of the weightlessness and microgravity. Lastly, it should fit into a bioprocess. The design of the space bioreactor is described in view of these considerations. A flow chart of the bioreactor is presented and discussed.

  8. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  9. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  10. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... are certified as NIST-traceable within 0.1% uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your highest calibration weight has no greater...

  11. Dr. Quincy, Move Over!

    ERIC Educational Resources Information Center

    Mason, David H.

    1988-01-01

    Introduces a life science classroom activity for developing a knowledge of the human skeletal system, environmental poisoning, and bone growth pattern. Provides the situation, an organizational flow chart, relevant information materials, and directions. (YP)

  12. Establishment of Traceability of Reference Grade Hydrometers at National Physical Laboratory, India (npli)

    NASA Astrophysics Data System (ADS)

    Kumar, Anil; Kumar, Harish; Mandal, Goutam; Das, M. B.; Sharma, D. C.

    The present paper discusses the establishment of traceability of reference grade hydrometers at National Physical Laboratory, India (NPLI). The reference grade hydrometers are calibrated and traceable to the primary solid density standard. The calibration has been done according to standard procedure based on Cuckow's Method and the reference grade hydrometers calibrated covers a wide range. The uncertainty of the reference grade hydrometers has been computed and corrections are also calculated for the scale readings, at which observations are taken.

  13. Association between hospital size and quality improvement for pharmaceutical services.

    PubMed

    Nau, David P; Garber, Mathew C; Lipowski, Earlene E; Stevenson, James G

    2004-01-15

    The relationship between hospital size and quality improvement (QI) for pharmaceutical services was studied. A questionnaire on QI was sent to hospital pharmacy directors in Michigan and Florida in 2002. The questionnaire included items on QI lead-team composition, QI tools, QI training, and QI culture. Usable responses were received from 162 (57%) of 282 pharmacy directors. Pharmacy QI lead teams were present in 57% of institutions, with larger teams in large hospitals (> or = 300 patients). Only two QI tools were used by a majority of hospitals: root-cause analysis (62%) and flow charts (66%). Small hospitals (< 50 patients) were less likely than medium-sized hospitals (50-299 patients) and large hospitals to use several QI tools, including control charts, cause-and-effect diagrams, root-cause analysis, flow charts, and histograms. Large hospitals were more likely than small and medium-sized hospitals to use root-cause analysis and control charts. There was no relationship between hospital size and the frequency with which physician or patient satisfaction with pharmaceutical services was measured. There were no differences in QI training or QI culture across hospital size categories. A survey suggested that a majority of hospital pharmacies in Michigan and Florida have begun to adopt QI techniques but that most are not using rigorous QI tools. Pharmacies in large hospitals had more QI lead-team members and were more likely to use certain QI tools, but there was no relationship between hospital size and satisfaction measurements, QI training, or QI culture.

  14. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... are certified as NIST-traceable within 0.1 % uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your lowest calibration weight has no greater than...

  15. 40 CFR 1065.790 - Mass standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... are certified as NIST-traceable within 0.1 % uncertainty. Calibration weights may be certified by any calibration lab that maintains NIST-traceability. Make sure your lowest calibration weight has no greater than...

  16. New SI-traceable reference gas mixtures for sulfur hexafluoride (SF6) at the pmol/mol level using static and dynamic preparation methods and comparison to existing scales

    NASA Astrophysics Data System (ADS)

    Wyss, Simon A.; Guillevic, Myriam; Vicar, Martin; Nieuwenkamp, Gerard; Vollmer, Martin K.; Pascale, Céline; Reimann, Stefan; Niederhauser, Bernhard; Emmenegger, Lukas

    2017-04-01

    We developed two SI-traceable methods, using both static and dynamic preparation steps, to produce reference gas mixtures for sulfur hexafluoride (SF6) in gas cylinders at pmol/mol level. This research activity is conducted under the framework of the European EMRP HIGHGAS project, in support of the high quality measurements of this important greenhouse gas in the earth's atmosphere. In the method used by the Czech Metrology Institute (CMI) a parent mixture of SF6 in synthetic air was produced in an aluminium cylinder at VSL as a first step. This mixture was produced gravimetrically according to ISO 6142 at an amount fraction of 1 μmol/mol. In the second step this primary standard was further diluted to near-ambient amount fraction, with the use of a three-step dilution system and directly pressurised into aluminium cylinders to a pressure of 10 bars. The second method used by the Federal Institute of Metrology (METAS) has already been applied to other fluorinated gases such as HFC-125 and HFC-1234yf. In this method a highly concentrated mixture is produced by spiking a purified synthetic air (matrix gas) with SF6 from a permeation device. The mass loss of SF6 in the permeation device is observed by a magnetic suspension balance. In a second step this mixture is diluted with matrix gas to the desired concentrations. All flows are controlled with mass flow controllers. The diluted gas was transferred into Silconert2000-coated stainless steel cylinders by cryo-filling. The final gas mixtures at near-ambient amount fraction were measured on a Medusa gas chromatography-mass spectrometry system (Medusa-GC/MS) against working standards calibrated on existing scales of the Scripps Institution of Oceanography (SIO) and compared to other scales [1]. The agreement of the assigned values by the CMI and METAS, with the measured values referenced on the SIO scale was excellent. This results show that with this methods we are able to produce accurate SI-traceable gas mixtures at near-ambient amount fraction for SF6, without extensive static dilutions. [1] Benjamin R. Miller, Ray F. Weiss, Peter K. Salameh, Toste Tanhua, Brian R. Greally, Jens Mühle, Peter G. Simmonds, Anal. Chem., 2008, 80, 1536.

  17. A medium-term follow-up study of a cohort of Chinese patients after first hospitalisation in a gazetted hospital for mania.

    PubMed

    Cheung, K Y; Dunn, E L W

    2010-03-01

    To study the characteristics of a cohort of first-episode manic patients treated in a regional psychiatric unit in Hong Kong, to explore the predictors of re-admission, and to investigate their functional outcomes 4 years after first hospitalisation. This was a medium-term follow-up study, using retrospective review of hospital records and clinical interviews at follow-up. Forty-four Chinese patients diagnosed as having their first-episode mania were discharged from a gazetted psychiatric ward in Hong Kong between January 1999 and June 2002. Their clinical characteristics on admission and prescribed medications on discharge were investigated. Their re-admission status was charted. The patients were contacted for follow-up assessment of their functional outcome at 4 years after their first hospitalisation. In our cohort of 44 patients, their first-episode mania mostly presented in young adulthood, as significantly disturbed behaviour deemed to require compulsory admission. Nineteen (43%) of the patients were re-admitted at least once within 4 years of being discharged, 6 of whom were re-admitted more than once. Compulsory admission at the first-episode mania predicted future re-admission. Alcohol and substance abuse were associated with earlier re-admission after the first-episode mania. None of the patients died. For those who were reassessed (28 patients), most lived with family members. In all, 21 patients were able to sustain open employment at 4 years after discharge. About half (n = 14) of the traceable patients were able to continue in full-time employment at 4 years, while 7 were doing part-time work. The median Global Assessment of Functioning score of the traceable group was 88. The results of this local study on patients with their first-episode of hospitalisation for mania were comparable to findings reported in western studies.

  18. ROMPS critical design review. Volume 3: Furnace module design documentation

    NASA Technical Reports Server (NTRS)

    Dobbs, M. E.

    1992-01-01

    As part of the furnace module design documentation, the furnace module Easylab programs definitions and command variables are described. Also included are Easylab commands flow charts and fault conditions.

  19. Early Grades Ideas.

    ERIC Educational Resources Information Center

    Classroom Computer Learning, 1984

    1984-01-01

    Five computer-oriented classroom activities are suggested. They include: Logo programming to help students develop estimation, logic and spatial skills; creating flow charts; inputting data; making snowflakes using Logo; and developing and using a database management program. (JN)

  20. 16 CFR 1211.5 - General testing parameters.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... condition flow chart shown in figure 1 shall be used: (1) To conduct a failure-mode and effect analysis (FMEA); (2) In investigating the performance during the Environmental Stress Tests; and (3) During the...

  1. Possible Aural Activities in the Listening Class.

    ERIC Educational Resources Information Center

    Zhiqian, Wu

    1989-01-01

    Some aural activities are described that can help language students with their listening comprehension. They include dictation, a "who am I?" exercise, sketch-drawing, chart completion, a comparison exercise, and a flow diagram. (LB)

  2. A dynamic gravimetric standard for trace water.

    PubMed

    Brewer, P J; Goody, B A; Woods, P T; Milton, M J T

    2011-10-01

    A system for generating traceable reference standards of water vapor at trace levels between 5 and 2000 nmol/mol has been developed. It can provide different amount fractions of trace water vapor by using continuous accurate measurements of mass loss from a permeation device coupled with a dilution system based on an array of critical flow orifices. An estimated relative expanded uncertainty of ±2% has been achieved for most amount fractions generated. The system has been used in an international comparison and demonstrates excellent comparability with National Metrology Institutes maintaining standards of water vapor in this range using other methods.

  3. Paper to Electronic Questionnaires: Effects on Structured Questionnaire Forms

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.

    2009-01-01

    With the use of computers, paper questionnaires are being replaced by electronic questionnaires. The formats of traditional paper questionnaires have been found to effect a subject's rating. Consequently, the transition from paper to electronic format can subtly change results. The research presented begins to determine how electronic questionnaire formats change subjective ratings. For formats where subjects used a flow chart to arrive at their rating, starting at the worst and middle ratings of the flow charts were the most accurate but subjects took slightly more time to arrive at their answers. Except for the electronic paper format, starting at the worst rating was the most preferred. The paper and electronic paper versions had the worst accuracy. Therefore, for flowchart type of questionnaires, flowcharts should start at the worst rating and work their way up to better ratings.

  4. Fundamental aerodynamic characteristics of delta wings with leading-edge vortex flows

    NASA Technical Reports Server (NTRS)

    Wood, R. M.; Miller, D. S.

    1985-01-01

    An investigation of the aerodynamics of sharp leading-edge delta wings at supersonic speeds has been conducted. The supporting experimental data for this investigation were taken from published force, pressure, and flow-visualization data in which the Mach number normal to the wing leading edge is always less than 1.0. The individual upper- and lower-surface nonlinear characteristics for uncambered delta wings are determined and presented in three charts. The upper-surface data show that both the normal-force coefficient and minimum pressure coefficient increase nonlinearly with a decreasing slope with increasing angle of attack. The lower-surface normal-force coefficient was shown to be independent of Mach number and to increase nonlinearly, with an increasing slope, with increasing angle of attack. These charts are then used to define a wing-design space for sharp leading-edge delta wings.

  5. Tables and charts of equilibrium normal shock and shock tube solutions for pure CO2 with velocities to 16 km/second

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1974-01-01

    Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves in pure CO2, representative of Mars and Venus atmospheres. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular weight ratio, isentropic exponent, velocity and species mole fractions. Incident (moving) shock velocities are varied from 1 to 16 km/sec for a range of initial pressure of 5 Newtons per square meter to 500 kilo Newtons per square meter. The present results are applicable to shock tube flows, and to free-flight conditions for a blunt body at high velocities. Working charts illustrating idealized shock-tube performance with CO2 test gas and heated helium and hydrogen driver gases are also presented.

  6. Traceable nanoscale measurement at NML-SIRIM

    NASA Astrophysics Data System (ADS)

    Dahlan, Ahmad M.; Abdul Hapip, A. I.

    2012-06-01

    The role of national metrology institute (NMI) has always been very crucial in national technology development. One of the key activities of the NMI is to provide traceable measurement in all parameters under the International System of Units (SI). Dimensional measurement where size and shape are two important features investigated, is one of the important area covered by NMIs. To support the national technology development, particularly in manufacturing sectors and emerging technology such nanotechnology, the National Metrology Laboratory, SIRIM Berhad (NML-SIRIM), has embarked on a project to equip Malaysia with state-of-the-art nanoscale measurement facility with the aims of providing traceability of measurement at nanoscale. This paper will look into some of the results from current activities at NML-SIRIM related to measurement at nanoscale particularly on application of atomic force microscope (AFM) and laser based sensor in dimensional measurement. Step height standards of different sizes were measured using AFM and laser-based sensors. These probes are integrated into a long-range nanoscale measuring machine traceable to the international definition of the meter thus ensuring their traceability. Consistency of results obtained by these two methods will be discussed and presented. Factors affecting their measurements as well as their related uncertainty of measurements will also be presented.

  7. EPA’s Hg Gas Traceability Approach for Source Emissions Measurement and Monitoring

    EPA Science Inventory

    Solicited presentation (special topic) at the International Conference on Mercury as a Global Pollutant on how EPA establishes the NIST traceability of reference materials used to support regulatory mercury emissions measurements.

  8. Recent advance in DNA-based traceability and authentication of livestock meat PDO and PGI products.

    PubMed

    Nicoloso, Letizia; Crepaldi, Paola; Mazza, Raffaele; Ajmone-Marsan, Paolo; Negrini, Riccardo

    2013-04-01

    This review updates the available molecular techniques and technologies and discusses how they can be used for traceability, food control and enforcement activities. The review also provides examples on how molecular techniques succeeded to trace back unknowns to their breeds of origin, to fingerprint single individuals and to generate evidence in court cases. The examples demonstrate the potential of the DNA based traceability techniques and explore possibilities for translating the next generation genomics tools into a food and feed control and enforcement framework.

  9. A simulation model for wind energy storage systems. Volume 3: Program descriptions

    NASA Technical Reports Server (NTRS)

    Warren, A. W.; Edsinger, R. W.; Burroughs, J. D.

    1977-01-01

    Program descriptions, flow charts, and program listings for the SIMWEST model generation program, the simulation program, the file maintenance program, and the printer plotter program are given. For Vol 2, see .

  10. Deccan volcanism and K-T boundary signatures

    NASA Technical Reports Server (NTRS)

    Murali, A. V.; Schuraytz, B. C.; Parekh, P. P.

    1988-01-01

    The Deccan Traps in the Indian subcontinent represent one of the most extensive flood basalt provinces in the world. These basalts occur mainly as flat-lying, subaerially erupted tholeiitic lava flows, some of which are traceable for distances of more than 100 km. Offshore drilling and geophysical surveys indicate that a part of the Deccan subsided or was downfaulted to the west beneath the Arabian Sea. The presence of 1 to 5 m thick intertrappean sediments deposited by lakes and rivers indicates periods of quiescence between eruptions. The occurrence of numerous red bole beds among the flows suggests intense weathering of flow tops between eruptive intervals. Although the causative relationship of the Cretaceous-Tertiary (K-T) biotic extinctions to Deccan volcanism is debatable, the fact that the main Deccan eruptions straddle the K-T event appears beyond doubt from the recent Ar-40/Ar-39 ages of various Deccan flows. This temporal relationship of the K-T event with Deccan volcanism makes the petrochemical signatures of the entire Deccan sequence (basalt flows, intercalated intertrappean sediments, infratrappean Lameta beds (with dinosaur fossils), and the bole beds) pertinent to studies of the K-T event. The results of ongoing study is presented.

  11. Traceability of Biologics in The Netherlands: An Analysis of Information-Recording Systems in Clinical Practice and Spontaneous ADR Reports.

    PubMed

    Klein, Kevin; Scholl, Joep H G; Vermeer, Niels S; Broekmans, André W; Van Puijenbroek, Eugène P; De Bruin, Marie L; Stolk, Pieter

    2016-02-01

    Pharmacovigilance requirements for biologics mandate that EU Member States shall ensure that any biologic that is the subject of a suspected adverse drug reaction (ADR) is identifiable by brand name and batch number. Recent studies showed that brand name identification is well established, whereas batch numbers are (still) poorly reported. We evaluated information-recording systems and practices in the Dutch hospital setting to identify determinants for brand name and batch number recording as well as success factors and bottlenecks for traceability. We surveyed Dutch hospital pharmacists with an online questionnaire on systems and practices in hospitals for recording brand names and batch numbers. Additionally, we performed an analysis of the traceability of recombinant biologics in spontaneous ADR reports (received between 2009 and 2014) from the Netherlands Pharmacovigilance Centre Lareb. The survey showed that brand names are not routinely recorded in the clinical practice of Dutch hospitals, whereas batch numbers are poorly recorded. Seventy-six percent of the 1523 ADR reports for recombinant biologics had a traceable brand name whereas 5% of these reports contained a batch number. The results suggest a possible relationship between the availability of brand and batch number information in clinical practice and the inclusion of this information in ADR reports for biologics. The limited traceability of brand names and batch numbers in ADR reports may be primarily caused by the shortcomings in the recording of information in clinical practice. We recommend efforts to improve information-recording systems as a first step to improve the traceability of biologics in ADR reporting.

  12. A Brain-Machine-Brain Interface for Rewiring of Cortical Circuitry after Traumatic Brain Injury

    DTIC Science & Technology

    2011-09-01

    cerebral cortex of a rat’s brain. The flow chart for spike discrimination algorithm is also shown. Negative threshold level (not shown in bottom left...portion of the transistor drain current can flow into its bulk due to impact ionization effect [40], greatly degrading the output impedance of the...current source. This can be solved by connecting the bulk and source of together, as also seen in Fig. 4, allowing its drain-bulk current to also flow

  13. Glutamate Receptor Aptamers and ALS

    DTIC Science & Technology

    2008-01-01

    XXGATC ACC Consensus sequence RNA library Cloning and sequencing SELEX DIAGRAM Fig. 1. (a) Flow chart of SELEX. The library we used for SELEX...recording electrode and placed ~100 µm away from the hole. The linear flow rate of the solution is 1-4 cm/s. An optical fiber through which laser light for...channel recording (26) GluR6Q 1.1 × 104 4.2 × 102 Laser-pulse photolysis (67) 1.0 × 104 4.4 × 102 Fitting (52) 1.0 × 104 Flow measurement (46

  14. High Fidelity Modeling of Field-Reversed Configuration (FRC) Thrusters (Briefing Charts)

    DTIC Science & Technology

    2017-05-24

    Converged Math → Irrelevant Solutions? Validation: Fluids Example Stoke’s Flow MARTIN, SOUSA, TRAN (AFRL/RQRS) DISTRIBUTION A - APPROVED FOR PUBLIC RELEASE...Convergence Tests Converged Math → Irrelevant Solutions? Must be Aware of Valid Assumption Regions Validation: Fluids Example Stoke’s Flow Potential...AND VALIDATION Verification: Asymptotic Models → Analytical Solutions Yields Exact Convergence Tests Converged Math → Irrelevant Solutions? Must be

  15. USCEA/NIST measurement assurance programs for the radiopharmaceutical and nuclear power industries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golas, D.B.

    1993-12-31

    In cooperation with the U.S. Council for Energy Awareness (USCEA), the National Institute of Standards and Technology (NIST) supervises and administers two measurement assurance programs for radioactivity measurement traceability. One, in existence since the mid 1970s, provides traceability to suppliers of radiochemicals and radiopharmaceuticals, dose calibrators, and nuclear pharmacy services. The second program, begun in 1987, provides traceability to the nuclear power industry for utilities, source suppliers, and service laboratories. Each program is described, and the results of measurements of samples of known, but undisclosed activity, prepared at NIST and measured by the participants are presented.

  16. Lightweight approach to model traceability in a CASE tool

    NASA Astrophysics Data System (ADS)

    Vileiniskis, Tomas; Skersys, Tomas; Pavalkis, Saulius; Butleris, Rimantas; Butkiene, Rita

    2017-07-01

    A term "model-driven" is not at all a new buzzword within the ranks of system development community. Nevertheless, the ever increasing complexity of model-driven approaches keeps fueling all kinds of discussions around this paradigm and pushes researchers forward to research and develop new and more effective ways to system development. With the increasing complexity, model traceability, and model management as a whole, becomes indispensable activities of model-driven system development process. The main goal of this paper is to present a conceptual design and implementation of a practical lightweight approach to model traceability in a CASE tool.

  17. Selection and use of microsatellite markers for individual identification and meat traceability of six swine breeds in the Chinese market.

    PubMed

    Zhao, Jie; Li, Tingting; Zhu, Chao; Jiang, Xiaoling; Zhao, Yan; Xu, Zhenzhen; Yang, Shuming; Chen, Ailiang

    2018-06-01

    Meat traceability based on molecular markers is exerting a great influence on food safety and will enhance its key role in the future. This study aimed to investigate and verify the polymorphism of 23 microsatellite markers and select the most suitable markers for individual identification and meat traceability of six swine breeds in the Chinese market. The mean polymorphism information content value of these 23 loci was 0.7851, and each locus exhibited high polymorphism in the pooled population. There were 10 loci showing good polymorphism in each breed, namely, Sw632, S0155, Sw2406, Sw830, Sw2525, Sw72, Sw2448, Sw911, Sw122 and CGA. When six highly polymorphic loci were combined, the match probability value for two random individual genotypes among the pig breeds (Beijing Black, Sanyuan and Taihu) was lower than 1.151 E-06. An increasing number of loci indicated a gradually decreasing match probability value and therefore enhanced traceability accuracy. The validation results of tracing 18 blood and corresponding meat samples based on five highly polymorphic loci (Sw2525, S0005, Sw0107, Sw911 and Sw857) were successful, with 100% conformation probability, which provided a foundation for establishing a traceability system for pork in the Chinese market.

  18. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics.

    PubMed

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao; Wang, Yuanzhong

    2018-01-15

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 192 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms.

  19. Feature Fusion of ICP-AES, UV-Vis and FT-MIR for Origin Traceability of Boletus edulis Mushrooms in Combination with Chemometrics

    PubMed Central

    Qi, Luming; Liu, Honggao; Li, Jieqing; Li, Tao

    2018-01-01

    Origin traceability is an important step to control the nutritional and pharmacological quality of food products. Boletus edulis mushroom is a well-known food resource in the world. Its nutritional and medicinal properties are drastically varied depending on geographical origins. In this study, three sensor systems (inductively coupled plasma atomic emission spectrophotometer (ICP-AES), ultraviolet-visible (UV-Vis) and Fourier transform mid-infrared spectroscopy (FT-MIR)) were applied for the origin traceability of 184 mushroom samples (caps and stipes) in combination with chemometrics. The difference between cap and stipe was clearly illustrated based on a single sensor technique, respectively. Feature variables from three instruments were used for origin traceability. Two supervised classification methods, partial least square discriminant analysis (FLS-DA) and grid search support vector machine (GS-SVM), were applied to develop mathematical models. Two steps (internal cross-validation and external prediction for unknown samples) were used to evaluate the performance of a classification model. The result is satisfactory with high accuracies ranging from 90.625% to 100%. These models also have an excellent generalization ability with the optimal parameters. Based on the combination of three sensory systems, our study provides a multi-sensory and comprehensive origin traceability of B. edulis mushrooms. PMID:29342969

  20. Los Angeles congestion reduction demonstration (Metro ExpressLanes) program. National evaluation : exogenous factors test plan.

    DOT National Transportation Integrated Search

    1999-12-01

    The Traceability document consists of brief introductory material and a series of appended Trace Tables. These tables provide complete traceability of ITS User Service Requirements (USR) to elements of the National ITS Architecture. Additional Trace ...

  1. Gas dynamics. Second edition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John, J.E.A.

    1984-01-01

    The book treats the basic fundamentals of compressible flow and gas dynamics using a wide breadth of topical coverage. It emphasizes the clear, logical development of basic theory and applies theory to real engineering systems. New in this edition is a complete changeover from English units to SI units. New charts for computing flows containing conical shock waves and expanded tables for isentropic flow and normal shocks are featured. The text emphasizes one dimensional and internal flow, and contains: improved illustrations; many new homework problems; examples and problems involving current applications; and new Mollier diagrams for computing real gas effects.

  2. A PROPOSED CHEMICAL INFORMATION AND DATA SYSTEM. VOLUME I.

    DTIC Science & Technology

    CHEMICAL COMPOUNDS, *DATA PROCESSING, *INFORMATION RETRIEVAL, * CHEMICAL ANALYSIS, INPUT OUTPUT DEVICES, COMPUTER PROGRAMMING, CLASSIFICATION...CONFIGURATIONS, DATA STORAGE SYSTEMS, ATOMS, MOLECULES, PERFORMANCE( ENGINEERING ), MAINTENANCE, SUBJECT INDEXING, MAGNETIC TAPE, AUTOMATIC, MILITARY REQUIREMENTS, TYPEWRITERS, OPTICS, TOPOLOGY, STATISTICAL ANALYSIS, FLOW CHARTING.

  3. As-built design specification for CAMS Development Dot Data System (CDDDS)

    NASA Technical Reports Server (NTRS)

    Wehmanen, O. A.

    1979-01-01

    The CAMS development dot data system is described. Listings and flow charts of the eight programs used to maintain the data base and the 15 subroutines used in FORTRAN programs to process the data are presented.

  4. Blockchain protocols in clinical trials: Transparency and traceability of consent.

    PubMed

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2017-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients' informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient's consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility.

  5. Blockchain protocols in clinical trials: Transparency and traceability of consent

    PubMed Central

    Benchoufi, Mehdi; Porcher, Raphael; Ravaud, Philippe

    2018-01-01

    Clinical trial consent for protocols and their revisions should be transparent for patients and traceable for stakeholders. Our goal is to implement a process allowing for collection of patients’ informed consent, which is bound to protocol revisions, storing and tracking the consent in a secure, unfalsifiable and publicly verifiable way, and enabling the sharing of this information in real time. For that, we build a consent workflow using a trending technology called Blockchain. This is a distributed technology that brings a built-in layer of transparency and traceability. From a more general and prospective point of view, we believe Blockchain technology brings a paradigmatical shift to the entire clinical research field. We designed a Proof-of-Concept protocol consisting of time-stamping each step of the patient’s consent collection using Blockchain, thus archiving and historicising the consent through cryptographic validation in a securely unfalsifiable and transparent way. For each protocol revision, consent was sought again.  We obtained a single document, in an open format, that accounted for the whole consent collection process: a time-stamped consent status regarding each version of the protocol. This document cannot be corrupted and can be checked on any dedicated public website. It should be considered a robust proof of data. However, in a live clinical trial, the authentication system should be strengthened to remove the need for third parties, here trial stakeholders, and give participative control to the peer users. In the future, the complex data flow of a clinical trial could be tracked by using Blockchain, which core functionality, named Smart Contract, could help prevent clinical trial events not occurring in the correct chronological order, for example including patients before they consented or analysing case report form data before freezing the database. Globally, Blockchain could help with reliability, security, transparency and could be a consistent step toward reproducibility. PMID:29167732

  6. 40 CFR Appendix H to Part 75... - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false [Reserved] H Appendix H to Part 75-Revised Traceability Protocol No. 1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Appendix H to Part 75—Revised Traceability...

  7. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers o...

  8. 40 CFR Appendix H to Part 75... - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false [Reserved] H Appendix H to Part 75-Revised Traceability Protocol No. 1 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Appendix H to Part 75—Revised Traceability...

  9. Traceability System For Agricultural Productsbased on Rfid and Mobile Technology

    NASA Astrophysics Data System (ADS)

    Sugahara, Koji

    In agriculture, it is required to establish and integrate food traceability systems and risk management systems in order to improve food safety in the entire food chain. The integrated traceability system for agricultural products was developed, based on innovative technology of RFID and mobile computing. In order to identify individual products on the distribution process efficiently,small RFID tags with unique ID and handy RFID readers were applied. On the distribution process, the RFID tags are checked by using the readers, and transit records of the products are stored to the database via wireless LAN.Regarding agricultural production, the recent issues of pesticides misuse affect consumer confidence in food safety. The Navigation System for Appropriate Pesticide Use (Nouyaku-navi) was developed, which is available in the fields by Internet cell-phones. Based on it, agricultural risk management systems have been developed. These systems collaborate with traceability systems and they can be applied for process control and risk management in agriculture.

  10. Automatic summary generating technology of vegetable traceability for information sharing

    NASA Astrophysics Data System (ADS)

    Zhenxuan, Zhang; Minjing, Peng

    2017-06-01

    In order to solve problems of excessive data entries and consequent high costs for data collection in vegetable traceablility for farmers in traceability applications, the automatic summary generating technology of vegetable traceability for information sharing was proposed. The proposed technology is an effective way for farmers to share real-time vegetable planting information in social networking platforms to enhance their brands and obtain more customers. In this research, the influencing factors in the vegetable traceablility for customers were analyzed to establish the sub-indicators and target indicators and propose a computing model based on the collected parameter values of the planted vegetables and standard legal systems on food safety. The proposed standard parameter model involves five steps: accessing database, establishing target indicators, establishing sub-indicators, establishing standard reference model and computing scores of indicators. On the basis of establishing and optimizing the standards of food safety and traceability system, this proposed technology could be accepted by more and more farmers and customers.

  11. A false single nucleotide polymorphism generated by gene duplication compromises meat traceability.

    PubMed

    Sanz, Arianne; Ordovás, Laura; Zaragoza, Pilar; Sanz, Albina; de Blas, Ignacio; Rodellar, Clementina

    2012-07-01

    Controlling meat traceability using SNPs is an effective method of ensuring food safety. We have analyzed several SNPs to create a panel for bovine genetic identification and traceability studies. One of these was the transversion g.329C>T (Genbank accession no. AJ496781) on the cytochrome P450 17A1 gene, which has been included in previously published panels. Using minisequencing reactions, we have tested 701 samples belonging to eight Spanish cattle breeds. Surprisingly, an excess of heterozygotes was detected, implying an extreme departure from Hardy-Weinberg equilibrium (P<0.001). By alignment analysis and sequencing, we detected that the g.329C>T SNP is a false positive polymorphism, which allows us to explain the inflated heterozygotic value. We recommend that this ambiguous SNP, as well as other polymorphisms located in this region, should not be used in identification, traceability or disease association studies. Annotation of these false SNPs should improve association studies and avoid misinterpretations. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Maintaining Traceability in an Evolving Distributed Computing Environment

    NASA Astrophysics Data System (ADS)

    Collier, I.; Wartel, R.

    2015-12-01

    The management of risk is fundamental to the operation of any distributed computing infrastructure. Identifying the cause of incidents is essential to prevent them from re-occurring. In addition, it is a goal to contain the impact of an incident while keeping services operational. For response to incidents to be acceptable this needs to be commensurate with the scale of the problem. The minimum level of traceability for distributed computing infrastructure usage is to be able to identify the source of all actions (executables, file transfers, pilot jobs, portal jobs, etc.) and the individual who initiated them. In addition, sufficiently fine-grained controls, such as blocking the originating user and monitoring to detect abnormal behaviour, are necessary for keeping services operational. It is essential to be able to understand the cause and to fix any problems before re-enabling access for the user. The aim is to be able to answer the basic questions who, what, where, and when concerning any incident. This requires retaining all relevant information, including timestamps and the digital identity of the user, sufficient to identify, for each service instance, and for every security event including at least the following: connect, authenticate, authorize (including identity changes) and disconnect. In traditional grid infrastructures (WLCG, EGI, OSG etc.) best practices and procedures for gathering and maintaining the information required to maintain traceability are well established. In particular, sites collect and store information required to ensure traceability of events at their sites. With the increased use of virtualisation and private and public clouds for HEP workloads established procedures, which are unable to see 'inside' running virtual machines no longer capture all the information required. Maintaining traceability will at least involve a shift of responsibility from sites to Virtual Organisations (VOs) bringing with it new requirements for their logging infrastructures. VOs indeed need to fulfil a new operational role and become fully active participants in the incident response process. We present an analysis of the changing requirements to maintain traceability for virtualised and cloud based workflows with particular reference to the work of the WLCG Traceability Working Group.

  13. Experimental and Metrological Basis for SI-Traceable Infrared Radiance Measurements From Space

    NASA Astrophysics Data System (ADS)

    Gero, P. J.; Dykema, J. A.; Anderson, J. G.; Leroy, S. S.

    2007-12-01

    In order to establish a climate benchmark record and to be useful in interdecadal climate forecast testing, satellite measurements of high spectral resolution infrared radiance must have uncertainty estimates that can be proven beyond a doubt. An uncertainty in radiance of about 1 part in 1000 is required for climate applications. This can be accomplished by appealing to the best measurement practices of the metrology community. The International System of Units (SI) are linked to fundamental physical properties of matter, and can be realized anywhere in the world without bias. By doing so, one can make an accurate observation to within a specified uncertainty. Achieving SI-traceable radiance measurements from space is a novel requirement, and requires specialized sensor design and a disciplined experimental approach. Infrared remote sensing satellite instruments typically employ blackbody calibration targets, which are tied to the SI through Planck's law and the definition of the Kelvin. The blackbody temperature and emissivity, however, must be determined accurately on- orbit, in order for the blackbody emission scale to be SI-traceable. We outline a methodology of instrument design, pre-flight calibration and on-orbit diagnostics for realizing SI- traceable infrared radiance measurements. This instrument is intended as a component of the Climate Absolute Radiance and Refractivity Earth Observatory (CLARREO), a high priority recommendation of the National Research Council decadal survey. Calibration blackbodies for remote sensing differ from a perfect Planckian blackbody; thus the component uncertainties must be evaluated in order to confer traceability. We have performed traceability experiments in the laboratory to verify blackbody temperature, emissivity and the end-to-end radiance scale. We discuss the design of the Harvard standard blackbody and an intercomparison campaign that will be conducted with the GIFTS blackbody (University of Wisconsin, Madison) and radiometric calibration facilities at NIST. The GIFTS blackbody is a high-performance space-qualified design with a new generation of on-orbit thermometer calibration via miniaturized fixed point cells. NIST facilities allow the step-by-step measurement of blackbody surface properties, thermal properties, on-axis emissivity, and end-to-end radiometric performance. These activities will lay the experimental groundwork for achieving SI-traceable infrared radiance measurements on a satellite instrument.

  14. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  15. Standards fabrication to providing metrological traceability in micromass and nanoforce measurements results

    NASA Astrophysics Data System (ADS)

    Vargas Pereira, Thaiane; Beatrici, Anderson

    2018-03-01

    Some of the more sensitive weighing equipment available nowadays has its repeatability close to tenth of microgram. OIML characterize mass standards bigger them 1 mg, so in this range doesn’t exist direct traceability to the kg prototype. The ASTM has a characterization of mass standard 50, 100, 200 e 500 micrograms. This work have a purpose of providing traceability to mass measurement in microgram scale (nanonewton scale in force) with the confection and calibration of a standard weights collection. At this time were studied two materials, Tungsten and MetGlass2705M (MetGlass), and produced 12 mass standards.

  16. Capillary electrophoresis for the analysis of contaminants in emerging food safety issues and food traceability.

    PubMed

    Vallejo-Cordoba, Belinda; González-Córdova, Aarón F

    2010-07-01

    This review presents an overview of the applicability of CE in the analysis of chemical and biological contaminants involved in emerging food safety issues. Additionally, CE-based genetic analyzers' usefulness as a unique tool in food traceability verification systems was presented. First, analytical approaches for the determination of melamine and specific food allergens in different foods were discussed. Second, natural toxin analysis by CE was updated from the last review reported in 2008. Finally, the analysis of prion proteins associated with the "mad cow" crises and the application of CE-based genetic analyzers for meat traceability were summarized.

  17. High-resolution interferometic microscope for traceable dimensional nanometrology in Brazil

    NASA Astrophysics Data System (ADS)

    Malinovski, I.; França, R. S.; Lima, M. S.; Bessa, M. S.; Silva, C. R.; Couceiro, I. B.

    2016-07-01

    The double color interferometric microscope is developed for step height standards nanometrology traceable to meter definition via primary wavelength laser standards. The setup is based on two stabilized lasers to provide traceable measurements of highest possible resolution down to the physical limits of the optical instruments in sub-nanometer to micrometer range of the heights. The wavelength reference is He-Ne 633 nm stabilized laser, the secondary source is Blue-Green 488 nm grating laser diode. Accurate fringe portion is measured by modulated phase-shift technique combined with imaging interferometry and Fourier processing. Self calibrating methods are developed to correct systematic interferometric errors.

  18. Metrological AFMs and its application for versatile nano-dimensional metrology tasks

    NASA Astrophysics Data System (ADS)

    Dai, Gaoliang; Dziomba, T.; Pohlenz, F.; Danzebrink, H.-U.; Koenders, L.

    2010-08-01

    Traceable calibrations of various micro and nano measurement devices are crucial tasks for ensuring reliable measurements for micro and nanotechnology. Today metrological AFM are widely used for traceable calibrations of nano dimensional standards. In this paper, we introduced the developments of metrological force microscopes at PTB. Of the three metrological AFMs described here, one is capable of measuring in a volume of 25 mm x 25 mm x 5 mm. All instruments feature interferometers and the three-dimensional position measurements are thus directly traceable to the metre definition. Some calibration examples on, for instance, flatness standards, step height standards, one and two dimensional gratings are demonstrated.

  19. The Endocrine Machinery.

    ERIC Educational Resources Information Center

    Fillman, David

    1987-01-01

    Promotes a reductionist approach to teaching about the endocrine system in high school biology and anatomy courses. Encourages the study of how hormones travel to the cells and affect them. Provides suggestions for activities and discussion questions, along with sample diagrams and flow charts. (TW)

  20. Airport landside volume V : appendix B ALSIM subroutines.

    DOT National Transportation Integrated Search

    1982-06-01

    This Appendix describes the operation of ten subroutines used to support the AUXILIARY and MAIN programs of ALSIM. Flow charts and listings of all programs are provided. The major portion describes the FORTRAN subprogram FORTM which is used to read i...

  1. Metrological traceability of holmium oxide solution

    NASA Astrophysics Data System (ADS)

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  2. Application of microsatellite markers as potential tools for traceability of Girgentana goat breed dairy products.

    PubMed

    Sardina, Maria Teresa; Tortorici, Lina; Mastrangelo, Salvatore; Di Gerlando, Rosalia; Tolone, Marco; Portolano, Baldassare

    2015-08-01

    In livestock, breed assignment may play a key role in the certification of products linked to specific breeds. Traceability of farm animals and authentication of their products can contribute to improve breed profitability and sustainability of animal productions with significant impact on the rural economy of particular geographic areas and on breed and biodiversity conservation. With the goal of developing a breed genetic traceability system for Girgentana dairy products, the aim of this study was to identify specific microsatellite markers able to discriminate among the most important Sicilian dairy goat breeds, in order to detect possible adulteration in Girgentana dairy products. A total of 20 microsatellite markers were analyzed on 338 individual samples from Girgentana, Maltese, and Derivata di Siria goat breeds. Specific microsatellite markers useful for traceability of dairy products were identified. Eight microsatellite markers showed alleles present at the same time in Maltese and Derivata di Siria and absent in Girgentana and, therefore, they were tested on DNA pools of the three breeds. Considering the electropherograms' results, only FCB20, SRCRSP5, and TGLA122 markers were tested on DNA samples extracted from cheeses of Girgentana goat breed. These three microsatellite markers could be applied in a breed genetic traceability system of Girgentana dairy products in order to detect adulteration due to Maltese and Derivata di Siria goat breeds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. TWO NEW GAS STANDARDS PROGRAMS AT THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY

    EPA Science Inventory

    The EPA/NIST certified reference materials (CRM) program is being terminated and replaced with two new ones: the NIST Traceable Reference Materials (NTRM) and the Research Gas Mixture (RGM) programs. hese new programs are being implemented to provide NIST traceability to a wider ...

  4. Determination of NIST-Traceable Quantitative Weight Percentage Purity for G Agent Standards

    DTIC Science & Technology

    Nuclear magnetic resonance (NMR) with phosphorus -31 detection is described to determine the weight percent purity of feedstock samples of agents GA...and GD in a way that is National Institute of Standards and Technology (NIST)-traceable. A Precision and Accuracy test is described.

  5. 75 FR 37377 - Notice of Revision and Request for Extension of Approval of an Information Collection; Animal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-29

    ... Traceability; Tribal Nations Using Systems for Location Identification AGENCY: Animal and Plant Health... using systems for location identification for the animal disease traceability framework and to request....aphis.usda.gov ). FOR FURTHER INFORMATION CONTACT: For information on Tribal Nations using location...

  6. Mercury Science Objectives and Traceability Within the BepiColombo Project: Optimising the Science Output of the Next Mission to Mercury

    NASA Astrophysics Data System (ADS)

    Besse, S.; Benkhoff, J.; Bentley, M.; Cornet, T.; Moissl, R.; Munoz, C.; Zender, J.

    2018-05-01

    The BepiColombo Science Ground Segment is developing, in collaboration with the instrument teams, targeted science traceability matrix of each instrument. They are defined in such a way that they can be tracked during the observation lifecycle.

  7. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards (EPA/600/R-12/531, May 2012)

    EPA Science Inventory

    In 1997, the U.S. Environmental Protection Agency (EPA) in Research Triangle Park, North Carolina, revised its 1993 version of its traceability protocol for the assay and certification of compressed gas and permeation-device calibration standards. The protocol allows producers of...

  8. Individualized Human CAD Models: Anthropmetric Morphing and Body Tissue Layering

    DTIC Science & Technology

    2014-07-31

    Part Flow Chart of the Interaction among VBA Macros, Excel® Spreadsheet, and SolidWorks Front View of the Male and Female Soldier CAD Model...yellow highlighting. The spreadsheet is linked to the CAD model by macros created with the Visual Basic for Application ( VBA ) editor in Microsoft Excel...basically three working parts to the anthropometric morphing that are all interconnected ( VBA macros, Excel spreadsheet, and SolidWorks). The flow

  9. Documentation: Motivation and training or automation

    NASA Technical Reports Server (NTRS)

    Mouton, M. L.

    1970-01-01

    The road blocks and mental blocks in areas where automation is not taking care of basic documentation problems are discussed. Original project documentation, documentation for project maintenance, and comparison of preliminary and final documentation are described. The use of flow charts is also mentioned.

  10. 48 CFR 852.211-70 - Service data manuals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... applicable, flow charts and narrative descriptions of software shall be provided. If programming is either...) Section IV, Principles of Operation. This section shall describe in narrative form the principles of... the recommended frequency of performance shall be included for visual inspection, cleaning...

  11. Map Your Way to a Better Lab.

    ERIC Educational Resources Information Center

    Roth, Wolff-Michael

    1990-01-01

    The use of concept maps, Vee diagrams, flow charts, and productive questions to increase student understanding of laboratory exercises and to improve student attitudes toward lab classes is discussed. Examples of each are provided. Student responses to these teaching methods are described. (CW)

  12. Multivariate statistical process control of a continuous pharmaceutical twin-screw granulation and fluid bed drying process.

    PubMed

    Silva, A F; Sarraguça, M C; Fonteyne, M; Vercruysse, J; De Leersnyder, F; Vanhoorne, V; Bostijn, N; Verstraeten, M; Vervaet, C; Remon, J P; De Beer, T; Lopes, J A

    2017-08-07

    A multivariate statistical process control (MSPC) strategy was developed for the monitoring of the ConsiGma™-25 continuous tablet manufacturing line. Thirty-five logged variables encompassing three major units, being a twin screw high shear granulator, a fluid bed dryer and a product control unit, were used to monitor the process. The MSPC strategy was based on principal component analysis of data acquired under normal operating conditions using a series of four process runs. Runs with imposed disturbances in the dryer air flow and temperature, in the granulator barrel temperature, speed and liquid mass flow and in the powder dosing unit mass flow were utilized to evaluate the model's monitoring performance. The impact of the imposed deviations to the process continuity was also evaluated using Hotelling's T 2 and Q residuals statistics control charts. The influence of the individual process variables was assessed by analyzing contribution plots at specific time points. Results show that the imposed disturbances were all detected in both control charts. Overall, the MSPC strategy was successfully developed and applied. Additionally, deviations not associated with the imposed changes were detected, mainly in the granulator barrel temperature control. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Guideline attribute and implementation preferences among physicians in multiple health systems.

    PubMed

    Stone, Tamara T; Schweikhart, Sharon B; Mantese, Annamarie; Sonnad, Seema S

    2005-01-01

    Although practice guidelines are effective in assisting providers with clinical decision making, ineffective implementation strategies often prevent their use in practice. This study aimed to understand physician preferences for guideline format, placement, content, evidence, and learning strategies in different clinical environments. Semistructured telephone interviews were conducted with 500 randomly selected physicians from 4 major US health systems who were involved in the treatment of patients with acute myocardial infarction or pediatric asthma. Paired sample t tests and Tukey's method of comparisons determined the relative ranking of physicians' guideline implementation preferences. Physicians preferred guidelines located on the front of the patient chart, in palm pilots, or in progress notes and presented as flow charts/flow diagrams, algorithms, or preprinted orders that contain strategies to minimize readmits/encourage self-management and immediate treatment flows. Discussions with colleagues and continuing medical education are the most effective strategies for encouraging guideline use, and randomized controlled trials remain the most persuasive medical evidence. Health care organizations must align guideline implementation efforts with physician preferences to encourage utilization. The results of this study reveal systematic physician preferences for guideline implementation that can be applied to clinical settings to encourage guideline use by physicians.

  14. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design

    NASA Astrophysics Data System (ADS)

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure—physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  15. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    PubMed

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  16. Towards sensible toxicity testing for nanomaterials: proposal for the specification of test design.

    PubMed

    Potthoff, Annegret; Weil, Mirco; Meißner, Tobias; Kühnel, Dana

    2015-12-01

    During the last decade, nanomaterials (NM) were extensively tested for potential harmful effects towards humans and environmental organisms. However, a sound hazard assessment was so far hampered by uncertainties and a low comparability of test results. The reason for the low comparability is a high variation in the (1) type of NM tested with regard to raw material, size and shape and (2) procedures before and during the toxicity testing. This calls for tailored, nanomaterial-specific protocols. Here, a structured approach is proposed, intended to lead to test protocols not only tailored to specific types of nanomaterials, but also to respective test system for toxicity testing. There are existing standards on single procedures involving nanomaterials, however, not all relevant procedures are covered by standards. Hence, our approach offers a detailed way of weighting several plausible alternatives for e.g. sample preparation, in order to decide on the procedure most meaningful for a specific nanomaterial and toxicity test. A framework of several decision trees (DT) and flow charts to support testing of NM is proposed as a basis for further refinement and in-depth elaboration. DT and flow charts were drafted for (1) general procedure-physicochemical characterisation, (2) choice of test media, (3) decision on test scenario and application of NM to liquid media, (4) application of NM to the gas phase, (5) application of NM to soil and sediments, (6) dose metrics, (S1) definition of a nanomaterial, and (S2) dissolution. The applicability of the proposed approach was surveyed by using experimental data retrieved from studies on nanoscale CuO. This survey demonstrated the DT and flow charts to be a convenient tool to systematically decide upon test procedures and processes, and hence pose an important step towards harmonisation of NM testing.

  17. Modelling a radiology department service using a VDL integrated approach.

    PubMed

    Guglielmino, Maria Gabriella; Celano, Giovanni; Costa, Antonio; Fichera, Sergio

    2009-01-01

    The healthcare industry is facing several challenges such as the reduction of costs and quality improvement of the provided services. Engineering studies could be very useful in supporting organizational and management processes. Healthcare service efficiency depends on a strong collaboration between clinical and engineering experts, especially when it comes to analyzing the system and its constraints in detail and subsequently, when it comes to deciding on the reengineering of some key activities. The purpose of this paper is to propose a case study showing how a mix of representation tools allow a manager of a radiology department to solve some human and technological resource re-organizational issues, which have to be faced due to the introduction of a new technology and a new portfolio of services. In order to simulate the activities within the radiology department and examine the relationship between human and technological resources, different visual diagrammatic language (VDL) techniques have been implemented to get knowledge about the heterogeneous factors related to the healthcare service delivery. In particular, flow charts, IDEFO diagrams and Petri nets have been integrated each other with success as a modelisation tools. The simulation study performed through the application of the aforementioned VDL techniques suggests the opportunity of re-organizing the nurse activities within the radiology department. The re-organization of a healthcare service and in particular of a radiology department by means of joint flow charts, IDEF0 diagrams and Petri nets is a poorly investigated topic in literature. This paper demonstrates how flow charts and IDEF0 can help people working within the department to understand the weak points of their organization and constitute an efficient base of knowledge for the implementation of a Petri net aimed at improving the departmental performance.

  18. Development of an air flow calorimeter prototype for the measurement of thermal power released by large radioactive waste packages.

    PubMed

    Razouk, R; Beaumont, O; Failleau, G; Hay, B; Plumeri, S

    2018-03-01

    The estimation and control of the thermal power released by the radioactive waste packages are a key parameter in the management of radioactive waste geological repository sites. In the framework of the European project "Metrology for decommissioning nuclear facilities," the French National Agency of Radioactive Waste Management (ANDRA) collaborates with Laboratoire National de Métrologie et D'essais in order to measure the thermal power up to 500 W of typical real size radioactive waste packages (of at least 0.175 m 3 ) with an uncertainty better than 5% by using a measurement method traceable to the international system of units. One of the selected metrological approaches is based on the principles of air flow calorimetry. This paper describes in detail the development of the air flow calorimeter prototype as well as the design of a radioactive waste package simulator used for its calibration. Results obtained from the calibration of the calorimeter and from the determination of thermal powers are presented here with an investigation of the measurement uncertainties.

  19. Instantaneous Doppler Global Velocimetry Measurements of a Rotor Wake: Lessons Learned

    NASA Technical Reports Server (NTRS)

    Meyers, James; Fleming, Gary A.; Gorton, Susan Althoff; Berry, John D.

    1998-01-01

    A combined Doppler Global Velocimetry (DGV) and Projection Moir Interferometry (PMI) investigation of a helicopter rotor wake flow field and rotor blade deformation is presented. The three-component DGV system uses a single-frequency, frequency-doubled Nd:YAG laser to obtain instantaneous velocity measurements in the flow. The PMI system uses a pulsed laser-diode bar to obtain blade bending and twist measurements at the same instant that DGV measured the flow. The application of pulse lasers to DGV and PMI in large-scale wind tunnel applications represents a major step forward in the development of these technologies. As such, a great deal was learned about the difficulties of using these instruments to obtain instantaneous measurements in large facilities. Laser speckle and other image noise in the DGV data images were found to be traceable to the Nd:YAG laser. Although image processing techniques were used to virtually eliminate laser speckle noise, the source of low-frequency image noise is still under investigation. The PMI results agreed well with theoretical predictions of blade bending and twist.

  20. Development of an air flow calorimeter prototype for the measurement of thermal power released by large radioactive waste packages

    NASA Astrophysics Data System (ADS)

    Razouk, R.; Beaumont, O.; Failleau, G.; Hay, B.; Plumeri, S.

    2018-03-01

    The estimation and control of the thermal power released by the radioactive waste packages are a key parameter in the management of radioactive waste geological repository sites. In the framework of the European project "Metrology for decommissioning nuclear facilities," the French National Agency of Radioactive Waste Management (ANDRA) collaborates with Laboratoire National de Métrologie et D'essais in order to measure the thermal power up to 500 W of typical real size radioactive waste packages (of at least 0.175 m3) with an uncertainty better than 5% by using a measurement method traceable to the international system of units. One of the selected metrological approaches is based on the principles of air flow calorimetry. This paper describes in detail the development of the air flow calorimeter prototype as well as the design of a radioactive waste package simulator used for its calibration. Results obtained from the calibration of the calorimeter and from the determination of thermal powers are presented here with an investigation of the measurement uncertainties.

  1. Table and charts of equilibrium normal shock and shock tube properties for pure argon with velocities to 18 km/sec

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1976-01-01

    Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves in pure argon. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular-weight ratio, isentropic exponent, velocity, and species mole fractions. Incident (moving) shock velocities are varied from 2 to 18 km/sec for a range of initial pressure of 5 N/sq m to 500 kN/sq m. Working charts illustrating shock tube performance with argon test gas and heated helium and hydrogen driver gases are also presented.

  2. Analyzing organic tea certification and traceability system within the Taiwanese tea industry.

    PubMed

    Wang, Mao-Chang; Yang, Chin-Ying

    2015-04-01

    We applied game theory to the organic tea certification process and traceability system used by the Taiwanese tea industry to elucidate the strategic choices made by tea farmers and organic tea certification agencies. Thus, this paper clarifies how relevant variables affect the organic certification process and traceability system used within the tea industry. The findings indicate that farmers who generate high revenues experience failures regarding tea deliveries, cash outflow, damage compensation, and quasi-rent. An additional problem included the high costs yielded when tea farmers colluded with or switched organic tea certification agencies. Furthermore, there could be decreasing levels of personal interest in planting non-organic tea and lowering the costs of planting organic tea and the managerial accounting costs of building comprehensive traceability systems; thus, the analysis yielded strong results and a superior equilibrium. This research is unprecedented, using an innovative model and providing a novel analysis structure for use in the tea industry. These results contribute to the field of literature and should serve as a valuable reference for members of the tea industry, government, and academia. © 2014 Society of Chemical Industry.

  3. [Study on brand traceability of vinegar based on near infrared spectroscopy technology].

    PubMed

    Guan, Xiao; Liu, Jing; Gu, Fang-Qing; Yang, Yong-Jian

    2014-09-01

    In the present paper, 152 vinegar samples with four different brands were chosen as research targets, and their near infrared spectra were collected by diffusion reflection mode and transmission mode, respectively. Furthermore, the brand traceability models for edible vinegar were constructed. The effects of the collection mode and pretreatment methods of spectrum on the precision of traceability models were investigated intensively. The models constructed by PLS1-DA modeling method using spectrum data of 114 training samples were applied to predict 38 test samples, and R2, RMSEC and RMSEP of the model based on transmission mode data were 0.92, 0.113 and 0.127, respectively, with recognition rate of 76.32%, and those based on diffusion reflection mode data were 0.97, 0.102 and 0.119, with recognition rate of 86.84%. The results demonstrated that the near infrared spectrum combined with PLS1-DA can be used to establish the brand traceability models for edible vinegar, and diffuse reflection mode is more beneficial for predictive ability of the model.

  4. Geographical traceability of virgin olive oils from south-western Spain by their multi-elemental composition.

    PubMed

    Beltrán, María; Sánchez-Astudillo, María; Aparicio, Ramón; García-González, Diego L

    2015-02-15

    The geographical traceability of virgin olive oil can be controlled by chemical species that are linked to the production area. Trace elements are among these species. The hypothesis is that the transfer of elements from the soil to the oil is subjected to minor variations and therefore this chemical information can be used for geographical traceability. In order to confirm this hypothesis, the trace elements of virgin olive oils from south-western Spain were analysed, and the same elements were determined in the corresponding olive-pomaces and soils. The differences in the concentration were studied according to cultivars and locations. Results show some coincidences in the selection of elements in soils (W, Fe, Na), olive-pomace (W, Fe, Na, Mg, Mn, Ca, Ba, Li) and olive oils (W, Fe, Mg, Mn, Ca, Ba, Li, Bi), which supports their utility in traceability. In the case of olive oils, 93% of the samples were correctly classified in their geographical origins (96% for Beas, 77% for Gibraleón, 91% for Niebla, and 100% for Sanlúcar de Guadiana). Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Troubleshooting Computer Problems--a Teachers' Guide.

    ERIC Educational Resources Information Center

    Zeitz, Leigh

    1995-01-01

    Presents a troubleshooting flow chart for teachers and others to use when trying to figure out why their computers do not work correctly. Written mainly for Macintosh computers, the purpose of this guide is to save school technology coordinators time and to help educate teachers. (Author/LRW)

  6. Development of an Aeromedical Scientific Information System for Aviation Safety

    DTIC Science & Technology

    2008-01-01

    math- ematics, engineering, computer hardware, software , and networking, was assembled to glean the most knowledge from the complicated aeromedical...9, SPlus Enterprise Developer 8, and Insightful Miner version 7. Process flow charts were done with SmartDraw Suite Edition version 7. Static and

  7. ACHP | Section 106 Regulations Flow Chart

    Science.gov Websites

    undertaking/no potential to cause effects Undertaking is type that might affect historic properties Identify No historic properties affected Historic properties are affected Assess Adverse Effects Apply affected Resolve Adverse Effects Continue consultation Memorandum of Agreement FAILURE TO AGREE COUNCIL

  8. A Primer on Functional Analysis

    ERIC Educational Resources Information Center

    Yoman, Jerome

    2008-01-01

    This article presents principles and basic steps for practitioners to complete a functional analysis of client behavior. The emphasis is on application of functional analysis to adult mental health clients. The article includes a detailed flow chart containing all major functional diagnoses and behavioral interventions, with functional assessment…

  9. Program to Optimize Simulated Trajectories (POST). Volume 3: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Brauer, G. L.; Cornick, D. E.; Habeger, A. R.; Petersen, F. M.; Stevenson, R.

    1975-01-01

    Information pertinent to the programmer and relating to the program to optimize simulated trajectories (POST) is presented. Topics discussed include: program structure and logic, subroutine listings and flow charts, and internal FORTRAN symbols. The POST core requirements are summarized along with program macrologic.

  10. Firefighting and Emergency Response Study of Advanced Composites Aircraft; Objective 1: Composite Material Damage in Minor Aircraft Fires

    DTIC Science & Technology

    2013-05-18

    26 4.3. 1-D Heat Transfer Model with Pyrolysis and Thermal Damage...Improvements and Added Features ........................................................................31 4.3.4. Pyrolysis Model Calibration... Pyrolysis Model ................................................32 Figure 25. Updated Heat Transfer Algorithm Flow Chart

  11. Tables and charts of equilibrium normal shock and shock-tube solutions for helium-hydrogen mixtures with velocities to 70 km/sec

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III; Wilder, S. E.

    1974-01-01

    Equilibrium thermodynamic and flow properties are presented in tabulated and graphical form for moving, standing, and reflected normal shock waves into helium-hydrogen mixtures representative of proposed outer planet atmospheres. The volumetric compositions of these mixtures are 0.35He-0.65H2, 0.20He-0.80H2, and 0.05He-0.95H2. Properties include pressure, temperature, density, enthalpy, speed of sound, entropy, molecular-weight ratio, isentropic exponent, velocity, and species mole fractions. Incident (moving) shock velocities are varied from 4 to 70 km/sec for a range of initial pressure of 5 N/sq m to 100 kN/sq m. The present results are applicable to shock-tube flows and to free-flight conditions for a blunt body at high velocities. A working chart illustrating idealized shock-tube performance with a 0.20He-0.80H2 test gas and heated helium driver gas is also presented.

  12. An Analysis of Community Health Nurses Documentation: The Best Approach to Computerization

    PubMed Central

    Chalmers, M.

    1988-01-01

    The study explored and analyzed the actual patient-related documentation performed by a sample of community health nurses working in voluntary home health agencies. The outcome of the study was a system flow chart of that documentation and included: common components of the documentation, where in the existing systems they are recorded, when they are recorded by the nurse and why they are used by the nurses and administrative personnel in the agencies. The flow chart is suitable for use as a prototype for the development of a computer software package for the computerization of the patient-related documentation by community health nurses. General System and communication theories were used as a framework for this study. A thorough analysis of the documenation resulted in a complete and exhaustive explication of the documentation by community health nurses, as well as the identification of what parts of that documentation lend themselves most readily to computerization and what areas, if any, may not readily adapt to computerization.

  13. Decompressive craniectomy and hydrocephalus: proposal of a therapeutic flow chart.

    PubMed

    Peraio, Simone; Calcagni, Maria Lucia; Mattoli, Maria Vittoria; Marziali, Giammaria; DE Bonis, Pasquale; Pompucci, Angelo; Anile, Carmelo; Mangiola, Annunziato

    2017-12-01

    Decompressive craniectomy (DC) may be necessary to save the lives of patients suffering from intracranial hypertension. However, this procedure is not complication-free. Its two main complications are hydrocephalus and the sinking skin-flap syndrome (SSFS). The radiological findings and the clinical evaluation may be not enough to decide when and/or how to treat hydrocephalus in a decompressed patient. SSFS and hydrocephalus may be not unrelated. In fact, a patient affected by hydrocephalus, after the ventriculo-peritoneal shunt, can develop SSFS; on the other hand, SSFS per se can cause hydrocephalus. Treating hydrocephalus in decompressed patients can be challenging. Radiological findings and clinical evaluation may not be enough to define the most appropriate therapeutic strategy. Cerebrospinal fluid (CSF) dynamics and metabolic evaluations can represent important diagnostic tools for assessing the need of a CSF shunt in patients with a poor baseline neurologic status. Based on our experience, we propose a flow chart for treating decompressed patients affected by ventriculomegaly.

  14. New NIST Photomask Linewidth Standard

    NASA Astrophysics Data System (ADS)

    Potzick, James E.; Pedulla, J. Marc; Stocker, Michael T.

    2002-12-01

    NIST is preparing to issue the next generation in its line of binary photomask linewidth standards. Called SRM 2059, it was developed for calibrating microscopes used to measure linewidths on photomasks, and consists of antireflecting chrome line and space patterns on a 6 inch quartz substrate ( 6 × 6 × 0.25 inches, or 15.2 × 15.2 × 0.635 cm). Certified line- and space-widths range from nominal 0.250 μm to 32 μm, and pitches from 0.5 μm to 250 μm, and are traceable to the definition of the meter. NIST's reference value, the definition of the meter, is well defined and unconditionally stable. Any replacement or duplicate NIST linewidth standard will be traceable to this same reference, and thus traceable to any other NIST length standard. Such measurement traceability can be achieved only by evaluating the measurement uncertainty (not just the repeatability) of each length comparison in the metrology chain between the definition of the meter and the NIST linewidth standard. This process results in a confidence interval about the calibration result that has a 95% probability of containing the true value. While the meter (and the μm) are well-defined, the geometrical width of a chrome line with nonrectangular cross section is not, and so the "true value" linewidth must be carefully defined to best meet users' needs. The paper and presentation will describe how these mask features are measured at NIST and how their measurement traceability is accomplished.

  15. Detection and traceability of genetically modified organisms in the food production chain.

    PubMed

    Miraglia, M; Berdal, K G; Brera, C; Corbisier, P; Holst-Jensen, A; Kok, E J; Marvin, H J P; Schimmel, H; Rentsch, J; van Rie, J P P F; Zagon, J

    2004-07-01

    Both labelling and traceability of genetically modified organisms are current issues that are considered in trade and regulation. Currently, labelling of genetically modified foods containing detectable transgenic material is required by EU legislation. A proposed package of legislation would extend this labelling to foods without any traces of transgenics. These new legislations would also impose labelling and a traceability system based on documentation throughout the food and feed manufacture system. The regulatory issues of risk analysis and labelling are currently harmonised by Codex Alimentarius. The implementation and maintenance of the regulations necessitates sampling protocols and analytical methodologies that allow for accurate determination of the content of genetically modified organisms within a food and feed sample. Current methodologies for the analysis of genetically modified organisms are focused on either one of two targets, the transgenic DNA inserted- or the novel protein(s) expressed- in a genetically modified product. For most DNA-based detection methods, the polymerase chain reaction is employed. Items that need consideration in the use of DNA-based detection methods include the specificity, sensitivity, matrix effects, internal reference DNA, availability of external reference materials, hemizygosity versus homozygosity, extrachromosomal DNA, and international harmonisation. For most protein-based methods, enzyme-linked immunosorbent assays with antibodies binding the novel protein are employed. Consideration should be given to the selection of the antigen bound by the antibody, accuracy, validation, and matrix effects. Currently, validation of detection methods for analysis of genetically modified organisms is taking place. In addition, new methodologies are developed, including the use of microarrays, mass spectrometry, and surface plasmon resonance. Challenges for GMO detection include the detection of transgenic material in materials with varying chromosome numbers. The existing and proposed regulatory EU requirements for traceability of genetically modified products fit within a broader tendency towards traceability of foods in general and, commercially, towards products that can be distinguished from each other. Traceability systems document the history of a product and may serve the purpose of both marketing and health protection. In this framework, segregation and identity preservation systems allow for the separation of genetically modified and non-modified products from "farm to fork". Implementation of these systems comes with specific technical requirements for each particular step of the food processing chain. In addition, the feasibility of traceability systems depends on a number of factors, including unique identifiers for each genetically modified product, detection methods, permissible levels of contamination, and financial costs. In conclusion, progress has been achieved in the field of sampling, detection, and traceability of genetically modified products, while some issues remain to be solved. For success, much will depend on the threshold level for adventitious contamination set by legislation. Copryright 2004 Elsevier Ltd.

  16. Stability Analysis of High-Speed Boundary-Layer Flow with Gas Injection (Briefing Charts)

    DTIC Science & Technology

    2014-06-01

    Vitaly G. Soudakov; Ivett A Leyva 5e. TASK NUMBER 5f. WORK UNIT NUMBER Q0AF 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING...cases of low injection rates in which the N -factors in the near field region are below the critical level, shaping can produce a significant...Release; Distribution Unlimited Stability analysis of high-speed boundary-layer flow with gas injection Alexander Fedorov and Vitaly Soudakov Moscow

  17. An aspect-oriented approach for designing safety-critical systems

    NASA Astrophysics Data System (ADS)

    Petrov, Z.; Zaykov, P. G.; Cardoso, J. P.; Coutinho, J. G. F.; Diniz, P. C.; Luk, W.

    The development of avionics systems is typically a tedious and cumbersome process. In addition to the required functions, developers must consider various and often conflicting non-functional requirements such as safety, performance, and energy efficiency. Certainly, an integrated approach with a seamless design flow that is capable of requirements modelling and supporting refinement down to an actual implementation in a traceable way, may lead to a significant acceleration of development cycles. This paper presents an aspect-oriented approach supported by a tool chain that deals with functional and non-functional requirements in an integrated manner. It also discusses how the approach can be applied to development of safety-critical systems and provides experimental results.

  18. Advanced engineering environment pilot project.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwegel, Jill; Pomplun, Alan R.; Abernathy, Rusty

    2006-10-01

    The Advanced Engineering Environment (AEE) is a concurrent engineering concept that enables real-time process tooling design and analysis, collaborative process flow development, automated document creation, and full process traceability throughout a product's life cycle. The AEE will enable NNSA's Design and Production Agencies to collaborate through a singular integrated process. Sandia National Laboratories and Parametric Technology Corporation (PTC) are working together on a prototype AEE pilot project to evaluate PTC's product collaboration tools relative to the needs of the NWC. The primary deliverable for the project is a set of validated criteria for defining a complete commercial off-the-shelf (COTS) solutionmore » to deploy the AEE across the NWC.« less

  19. RELAP-7 Software Verification and Validation Plan: Requirements Traceability Matrix (RTM) Part 1 – Physics and numerical methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choi, Yong Joon; Yoo, Jun Soo; Smith, Curtis Lee

    2015-09-01

    This INL plan comprehensively describes the Requirements Traceability Matrix (RTM) on main physics and numerical method of the RELAP-7. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7.

  20. Hg0 and HgCl2 Reference Gas Standards: NIST Traceability and Comparability (And EPA ALT Methods for Hg and HCl )

    EPA Science Inventory

    EPA and NIST have collaborated to establish the necessary procedures for establishing the required NIST traceability of commercially-provided Hg0 and HgCl2 reference generators. This presentation will discuss the approach of a joint EPA/NIST study to accurately quantify the tru...

  1. Application of binomial and multinomial probability statistics to the sampling design process of a global grain tracing and recall system

    USDA-ARS?s Scientific Manuscript database

    Small, coded, pill-sized tracers embedded in grain are proposed as a method for grain traceability. A sampling process for a grain traceability system was designed and investigated by applying probability statistics using a science-based sampling approach to collect an adequate number of tracers fo...

  2. Simple Model of the Circulation.

    ERIC Educational Resources Information Center

    Greenway, Clive A.

    1980-01-01

    Describes a program in BASIC-11 that explores the relationships between various variables in the circulatory system and permits manipulation of several semiindependent variables to model the effects of hemorrhage, drug infusions, etc. A flow chart and accompanying sample printout are provided; the program is listed in the appendix. (CS)

  3. ACHP | Section 106 Regulations Users Guide

    Science.gov Websites

    related rules, policy issues, opinions, and guidance documents Section 106: The Rules Regulations Text Flow Chart and Explanatory Material Section-by-Section Questions and Answers Policy Statements ACHP Policy Statement on Historic Preservation and Community Revitalization Policy Statement on the ACHP's

  4. Model Experiment of Two-Dimentional Brownian Motion by Microcomputer.

    ERIC Educational Resources Information Center

    Mishima, Nobuhiko; And Others

    1980-01-01

    Describes the use of a microcomputer in studying a model experiment (Brownian particles colliding with thermal particles). A flow chart and program for the experiment are provided. Suggests that this experiment may foster a deepened understanding through mutual dialog between the student and computer. (SK)

  5. Historical and projected power requirements

    NASA Technical Reports Server (NTRS)

    Wolfe, M. G.

    1978-01-01

    Policy planning for projected space power requirements is discussed. Topics of discussion cover: (1) historical space power trends (prime power requirements and power system costs); and (2) two approaches to future space power requirements (mission/traffic model approach and advanced system scenario approach). Graphs, tables, and flow charts are presented.

  6. Systematic Technology Planning: GSFC Perspective

    NASA Technical Reports Server (NTRS)

    Steiner, Mark

    2004-01-01

    This viewgraph presentation describes the experiences of Goddard Space Flight Center (GSFC) in integrating systematic technology investment planning into the process of architecting NASA space missions. The presentation uses the assessment of a lidar mission as a case study, and illustrates integration strategies through flow charts and dynamic systems models.

  7. 40 CFR 49.139 - Rule for non-Title V operating permits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., the Tribal governing body, and the Tribal, State, and local air pollution authorities having... limitation. (C) A description of the production processes and a related flow chart. (D) Identification of...; (ii) Mass balance calculations; (iii) Published, verifiable emission factors that are applicable to...

  8. Programmer's guide for the GNAT computer program (numerical analysis of stratification in supercritical oxygen)

    NASA Technical Reports Server (NTRS)

    Heinmiller, J. P.

    1971-01-01

    This document is the programmer's guide for the GNAT computer program developed under MSC/TRW Task 705-2, Apollo cryogenic storage system analysis, subtask 2, is reported. Detailed logic flow charts and compiled program listings are provided for all program elements.

  9. DORCA 2 computer program. Volume 2: Programmer's manual

    NASA Technical Reports Server (NTRS)

    Gold, B. J.

    1972-01-01

    A guide for coding the Dynamic Operational Requirements and Cost Analysis Program (DORCA 2) is presented. The manual provides a detailed operation of every subroutine, the layout in core of the major matrices and arrays, and the meaning of all program values. Flow charts are included.

  10. 40 CFR 161.162 - Description of production process.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicant must submit information on the production (reaction) processes used to produce the active... continuous (a single reaction process from starting materials to active ingredient), but is accomplished in...) A flow chart of the chemical equations of each intended reaction occurring at each step of the...

  11. 40 CFR 161.162 - Description of production process.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... applicant must submit information on the production (reaction) processes used to produce the active... continuous (a single reaction process from starting materials to active ingredient), but is accomplished in...) A flow chart of the chemical equations of each intended reaction occurring at each step of the...

  12. Knowledge Engineering (Or, Catching Black Cats in Dark Rooms).

    ERIC Educational Resources Information Center

    Ruyle, Kim E.

    1993-01-01

    Discusses knowledge engineering, its relationship to artificial intelligence, and possible applications to developing expert systems, job aids, and technical training. The educational background of knowledge engineers is considered; the role of subject matter experts is described; and examples of flow charts, lists, and pictorial representations…

  13. Structured Programming on the 380-Z.

    ERIC Educational Resources Information Center

    Horton, Graeme

    1983-01-01

    With the production of SBAS, a combination of language and machine allowing for a disciplined and error-free approach to teaching programming is available. Instructional strategies for use with SBAS and basic concepts (decisions, repetitions/iterations, actions/processes) are discussed. Sample flow charts and program listings are provided. (JN)

  14. Design Document. EKG Interpretation Program.

    ERIC Educational Resources Information Center

    Webb, Sandra M.

    This teaching plan is designed to assist nursing instructors assigned to advanced medical surgical nursing courses in acquainting students with the basic skills needed to perform electrocardiographic (ECG or EKG) interpretations. The first part of the teaching plan contains a statement of purpose; audience recommendations; a flow chart detailing…

  15. Research and Construction of DC Energy Measurement Traceability Technology

    NASA Astrophysics Data System (ADS)

    Zhi, Wang; Maotao, Yang; Jing, Yang

    2018-02-01

    With the implementation of energy saving and emission reduction policies, DC energy metering has been widely used in many fields. In view of the lack of a DC energy measurementtraceability system, in combination with the process of downward measurement transfer in relation to the DC charger-based field calibration technology and DC energy meter and shunt calibration technologies, the paper proposed DC fast charging, high DC, small DC voltage output and measuring technologies, and built a time-based plan by converting high DC voltage into low voltage and high current into low current and then into low voltage, leaving DC energy traceable to national standards in terms of voltage, current and time and thus filling in the gap in DC energy measurement traceability.

  16. Transgene traceability in transgenic mice: a bioanalytical approach for potential gene-doping analysis.

    PubMed

    Bogani, Patrizia; Spiriti, Maria Michela; Lazzarano, Stefano; Arcangeli, Annarosa; Buiatti, Marcello; Minunni, Maria

    2011-11-01

    The World Anti-Doping Agency fears the use of gene doping to enhance athletic performances. Thus, a bioanalytical approach based on end point PCR for detecting markers' of transgenesis traceability was developed. A few sequences from two different vectors using an animal model were selected and traced in different tissues and at different times. In particular, enhanced green fluorescent protein gene and a construct-specific new marker were targeted in the analysis. To make the developed detection approach open to future routine doping analysis, matrices such as urine and tears as well blood were also tested. This study will have impact in evaluating the vector transgenes traceability for the detection of a gene doping event by non-invasive sampling.

  17. Calculations of Laminar Heat Transfer Around Cylinders of Arbitrary Cross Section and Transpiration-Cooled Walls with Application to Turbine Blade Cooling

    NASA Technical Reports Server (NTRS)

    Eckert, E.R.G.; Livingood, John N.B.

    1951-01-01

    An approximate method for development of flow and thermal boundary layers in laminar regime on cylinders with arbitrary cross section and transpiration-cooled walls is obtained by use of Karman's integrated momentum equation and an analogous heat-flow equation. Incompressible flow with constant property values throughout boundary layer is assumed. Shape parameters for approximated velocity and temperature profiles and functions necessary for solution of boundary-layer equations are presented as charts, reducing calculations to a minimum. The method is applied to determine local heat-transfer coefficients and surface temperature-cooled turbine blades for a given flow rate. Coolant flow distributions necessary for maintaining uniform blade temperatures are also determined.

  18. State of the art stationary and mobile infrastructure for the dynamic generation and dilution of traceable reference gas mixtures of Ammonia at ambient air amount fractions

    NASA Astrophysics Data System (ADS)

    Leuenberger, Daiana; Pascale, Céline; Guillevic, Myriam; Ackermann, Andreas; Niederhauser, Bernhard

    2017-04-01

    Ammonia (NH3) in the atmosphere is the major precursor for neutralising atmospheric acids and is thus affecting not only the long-range transport of sulphur dioxide and nitrogen oxides but also stabilises secondary particulate matter. These aerosols have negative impacts on air quality and human health. Moreover, they negatively affect terrestrial ecosystems after deposition. NH3 has been included in the air quality monitoring networks and emission reduction directives of European nations. Atmospheric concentrations are in the order of 0.5-500 nmol/mol. However, the lowest substance amount fraction of available certified reference material (CRM) is 10 μmol/mol. This due to the fact that adsorption on the walls of aluminium cylinders and desorption as pressure in the cylinder decreases cause substantial instabilities in the amount fractions of the gas mixtures. Moreover, analytical techniques to be calibrated are very diverse and cause challenges for the production and application of CRM. The Federal Institute of Metrology METAS has developed, partially in the framework of EMRP JRP ENV55 MetNH3, an infrastructure to meet with the different requirements in order to generate SI-traceable NH3 reference gas mixtures dynamically in the amount fraction range 0.5-500 nmol/mol and with uncertainties UNH3 <3%. The infrastructure consists of a stationary as well as a mobile device for full flexibility in the application: In the stationary system, a magnetic suspension balance monitors the specific temperature and pressure dependent mass loss over time of the pure substance in a permeation tube (here NH3) by permeation through a membrane into a constant flow of carrier gas. Subsequently, this mixture is diluted with a system of thermal mass flow controllers in one or two consecutive steps to desired amount fractions. The permeation tube with calibrated permeation rate (mass loss over time previously determined in the magnetic suspension balance) can be transferred into the temperature-regulated permeation chamber of a newly developed mobile reference gas generator (ReGaS1). In addition to the permeation chamber it consists of the same dilution system as afore mentioned, stationary system. All components are fully traceable to SI standards. Considerable effort has been made to minimise adsorption on the gas-wetted stainless steel surfaces and thus to reduce stabilisation times by applying the SilcoNert2000® coating substance. Analysers can be connected directly to both, stationary and mobile systems for calibration. Moreover, the resulting gas mixture can also be pressurised into coated cylinders by cryo-filling. The mobile system as well as these cylinders can be applied for calibrations in other laboratories and in the field. In addition, an SI traceable system based on a cascade of critical orifices has been established to dilute NH3 mixtures in the order of μmol/mol stored in cylinders for the participation in the international key-comparison CCQM K117. It is planned to establish this system to calibrate and re-sample gas cylinders due to its very economical gas use. Here we present insights into the development of said infrastructure and results of the first performance tests. Moreover, we include results of the study on adsorption/desorption effects in dry as well as humidified matrix gas into the discussion on the generation of reference gas mixtures. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

  19. SPICE: exploration and analysis of post-cytometric complex multivariate datasets.

    PubMed

    Roederer, Mario; Nozzi, Joshua L; Nason, Martha C

    2011-02-01

    Polychromatic flow cytometry results in complex, multivariate datasets. To date, tools for the aggregate analysis of these datasets across multiple specimens grouped by different categorical variables, such as demographic information, have not been optimized. Often, the exploration of such datasets is accomplished by visualization of patterns with pie charts or bar charts, without easy access to statistical comparisons of measurements that comprise multiple components. Here we report on algorithms and a graphical interface we developed for these purposes. In particular, we discuss thresholding necessary for accurate representation of data in pie charts, the implications for display and comparison of normalized versus unnormalized data, and the effects of averaging when samples with significant background noise are present. Finally, we define a statistic for the nonparametric comparison of complex distributions to test for difference between groups of samples based on multi-component measurements. While originally developed to support the analysis of T cell functional profiles, these techniques are amenable to a broad range of datatypes. Published 2011 Wiley-Liss, Inc.

  20. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    PubMed

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  1. The Allocation of Teachers in Schools--An Alternative to the Class Size Dialogue.

    ERIC Educational Resources Information Center

    Loader, David N.

    1978-01-01

    This article looks beyond class size to such specifics as teachers' load, subject electives available, subject load, and different class groupings in developing a flow chart that gives added understanding and control over the variables relating to the deployment of teachers. (Author/IRT)

  2. Think Quality! The Deming Approach Does Work in Libraries.

    ERIC Educational Resources Information Center

    Mackey, Terry; Mackey, Kitty

    1992-01-01

    Presents W. Edwards Deming's Total Quality Management method and advocates its adoption in libraries. The 14 points that form the basis of Deming's philosophy are discussed in the context of the library setting. A flow chart of the reference process and user survey questions are included. (MES)

  3. The High Cost of Eating.

    ERIC Educational Resources Information Center

    Slesnick, Irwin L.

    1983-01-01

    Discusses and provides questions for use in "Energy Flow in a Wetland," a game in which energy is examined as it passes through a wetland's food chain. Includes full-color, poster-size game board, rules, and an energy loss chart which lists calorie-consuming events organisms encounter during their lives. (JN)

  4. Public Opinion Poll Question Databases: An Evaluation

    ERIC Educational Resources Information Center

    Woods, Stephen

    2007-01-01

    This paper evaluates five polling resource: iPOLL, Polling the Nations, Gallup Brain, Public Opinion Poll Question Database, and Polls and Surveys. Content was evaluated on disclosure standards from major polling organizations, scope on a model for public opinion polls, and presentation on a flow chart discussing search limitations and usability.

  5. Blade loss transient dynamics analysis. Volume 3: User's manual for TETRA program

    NASA Technical Reports Server (NTRS)

    Black, G. R.; Gallardo, V. C.; Storace, A. S.; Sagendorph, F.

    1981-01-01

    The users manual for TETRA contains program logic, flow charts, error messages, input sheets, modeling instructions, option descriptions, input variable descriptions, and demonstration problems. The process of obtaining a NASTRAN 17.5 generated modal input file for TETRA is also described with a worked sample.

  6. Distance-Based and Distributed Learning: A Decision Tool for Education Leaders.

    ERIC Educational Resources Information Center

    McGraw, Tammy M.; Ross, John D.

    This decision tool presents a progression of data collection and decision-making strategies that can increase the effectiveness of distance-based or distributed learning instruction. A narrative and flow chart cover the following steps: (1) basic assumptions, including purpose of instruction, market scan, and financial resources; (2) needs…

  7. 14 CFR 93.69 - Special requirements, Lake Campbell and Sixmile Lake Airports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES... person operating an aircraft to or from Lake Campbell or Sixmile Lake Airport shall conform to the flow of traffic for the Lake operations that are depicted on the appropriate aeronautical charts. ...

  8. 14 CFR 93.69 - Special requirements, Lake Campbell and Sixmile Lake Airports.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES... person operating an aircraft to or from Lake Campbell or Sixmile Lake Airport shall conform to the flow of traffic for the Lake operations that are depicted on the appropriate aeronautical charts. ...

  9. 14 CFR 93.69 - Special requirements, Lake Campbell and Sixmile Lake Airports.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES... person operating an aircraft to or from Lake Campbell or Sixmile Lake Airport shall conform to the flow of traffic for the Lake operations that are depicted on the appropriate aeronautical charts. ...

  10. 14 CFR 93.67 - General rules: Bryant segment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Airport shall conform to the flow of traffic shown on the appropriate aeronautical charts, and while in the traffic pattern, shall operate that airplane at an altitude of at least 1,000 feet MSL until... (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal...

  11. 14 CFR 93.67 - General rules: Bryant segment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Airport shall conform to the flow of traffic shown on the appropriate aeronautical charts, and while in the traffic pattern, shall operate that airplane at an altitude of at least 1,000 feet MSL until... (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal...

  12. 14 CFR 93.69 - Special requirements, Lake Campbell and Sixmile Lake Airports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES... person operating an aircraft to or from Lake Campbell or Sixmile Lake Airport shall conform to the flow of traffic for the Lake operations that are depicted on the appropriate aeronautical charts. ...

  13. 14 CFR 93.67 - General rules: Bryant segment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Airport shall conform to the flow of traffic shown on the appropriate aeronautical charts, and while in the traffic pattern, shall operate that airplane at an altitude of at least 1,000 feet MSL until... (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal...

  14. 14 CFR 93.67 - General rules: Bryant segment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Airport shall conform to the flow of traffic shown on the appropriate aeronautical charts, and while in the traffic pattern, shall operate that airplane at an altitude of at least 1,000 feet MSL until... (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Anchorage, Alaska, Terminal...

  15. 14 CFR 93.69 - Special requirements, Lake Campbell and Sixmile Lake Airports.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES... person operating an aircraft to or from Lake Campbell or Sixmile Lake Airport shall conform to the flow of traffic for the Lake operations that are depicted on the appropriate aeronautical charts. ...

  16. 40 CFR 49.139 - Rule for non-Title V operating permits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the air pollution source, the Tribal governing body, and the Tribal, State, and local air pollution... limitation. (C) A description of the production processes and a related flow chart. (D) Identification of...; (ii) Mass balance calculations; (iii) Published, verifiable emission factors that are applicable to...

  17. 40 CFR 49.139 - Rule for non-Title V operating permits.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the air pollution source, the Tribal governing body, and the Tribal, State, and local air pollution... limitation. (C) A description of the production processes and a related flow chart. (D) Identification of...; (ii) Mass balance calculations; (iii) Published, verifiable emission factors that are applicable to...

  18. 40 CFR 49.139 - Rule for non-Title V operating permits.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the air pollution source, the Tribal governing body, and the Tribal, State, and local air pollution... limitation. (C) A description of the production processes and a related flow chart. (D) Identification of...; (ii) Mass balance calculations; (iii) Published, verifiable emission factors that are applicable to...

  19. 40 CFR 49.139 - Rule for non-Title V operating permits.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the air pollution source, the Tribal governing body, and the Tribal, State, and local air pollution... limitation. (C) A description of the production processes and a related flow chart. (D) Identification of...; (ii) Mass balance calculations; (iii) Published, verifiable emission factors that are applicable to...

  20. ILLIAC 4 systems characteristics and programming manual

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The latest edition is presented of the Systems Characteristics and Programming Manual of the ILLIAC 4 array and parallel disc memory system. The major aspects of the array described include: the array systems characteristics, programming characteristics, definition and flow charts, and timing. A glossary of terms, and an instruction index are included.

  1. Hello! Are You Registered?

    ERIC Educational Resources Information Center

    Institute for Political/Legal Education, Sewell, NJ.

    Organizational procedures and appropriate forms for high school students to conduct a community survey of non-registered voters are provided. Duties for student coordinator, field staff, and clerical staff are described and a flow chart depicts the relationship of personnel to one another and to the community. Students are instructed to notify…

  2. A Programmable Calculator Activity, x = 1/x + 1.

    ERIC Educational Resources Information Center

    Snover, Stephen L.; Spikell, Mark A.

    An activity for secondary schools is presented and discussed which may be explored with a programmable calculator. The activity is non-standard and could not be easily explored without the use of a programmable calculator. Related activities are also discussed. Flow charts and programs for different programmable calculators are presented. (MP)

  3. Competencies and Standards for Psychological Assessment, Intervention and Follow-Up.

    ERIC Educational Resources Information Center

    Grimes, Jeff; And Others

    Intended for self evaluation and improvement of school psychological services, the document lists competencies and standards for psychological assessment, intervention, and followup of children with suspected handicapping conditions. The first section presents a flow chart and a list of standards for seven competencies: referral; definition of…

  4. A Simple Exposition of the Social Security Trust Fund.

    ERIC Educational Resources Information Center

    Holahan, William L.; Schug, Mark C.

    2000-01-01

    Discusses a strategy for teaching students about how the Social Security Trust Fund works. Explains that a flow chart is presented to the students; four terms are defined (deficit, surplus, debt, and reserve); and a new graph is prepared to show the paths of these four variables. (CMK)

  5. Lexivisions: Making Meaning through Imaging.

    ERIC Educational Resources Information Center

    Iovino, Linda

    In a high school writing workshop, students frequently would go through multiple essay drafts and conferences with the teacher and fellow students before realizing that their theses were incorrect. A teacher devised the "lexivision" to address this problem. Students used Venn diagrams, graphs, or flow charts to represent concepts in the…

  6. Transonic Compressor: Program System TXCO for Data Acquisition and On-Line Reduction.

    DTIC Science & Technology

    1980-10-01

    IMONIDAYIYEARIHOUR,IMINISEC) OS16 C ............................................................... (0S17 C 0SiB C Gel dole ond line and convert the...linear curve fits SECON real intercept of linear curve fit (as from CURVE) 65 - . FLOW CHART SUBROUTINE CALIB - - - Aso C’A / oonre& *Go wSAt*irc

  7. Teaching Economics: A Cooperative Learning Model.

    ERIC Educational Resources Information Center

    Caropreso, Edward J.; Haggerty, Mark

    2000-01-01

    Describes an alternative approach to introductory economics based on a cooperative learning model, "Learning Together." Discussion of issues in economics education and cooperative learning in higher education leads to explanation of how to adapt the Learning Together Model to lesson planning in economics. A flow chart illustrates the process for a…

  8. Patterns in Liberal Arts Curricula: A Survey of Program Models.

    ERIC Educational Resources Information Center

    Kolling, Orland W.

    Characteristics of liberal arts education and different approaches to educational modeling are examined. Attention is directed to: applications of graphic depictions; Venn-Euler diagrams to represent inclusion-exclusion phenomena as well as areas of commonality in learning processes and liberal education; the uses of flow charts for describing…

  9. Teaching the Visual Learner: The Use of Visual Summaries in Marketing Education

    ERIC Educational Resources Information Center

    Clarke, Irvine, III.; Flaherty, Theresa B.; Yankey, Michael

    2006-01-01

    Approximately 40% of college students are visual learners, preferring to be taught through pictures, diagrams, flow charts, timelines, films, and demonstrations. Yet marketing instruction remains heavily reliant on presenting content primarily through verbal cues such as written or spoken words. Without visual instruction, some students may be…

  10. Real-World Flowcharting--Willy Wonka Style!

    ERIC Educational Resources Information Center

    Noe, Kelly

    2015-01-01

    The purpose of this paper is to discuss the development, implementation and outcome of a field-based learning flow-charting project that was conducted in an accounting information systems (AIS) course. The emphasis for the project was strengthening the students' critical thinking skills. This paper advances AIS education by sharing a field-based…

  11. Solving Quantitative Problems: Guidelines for Teaching Derived from Research.

    ERIC Educational Resources Information Center

    Kramers-Pals, H.; Pilot, A.

    1988-01-01

    Presents four guidelines for teaching quantitative problem-solving based on research results: analyze difficulties of students, develop a system of heuristics, select and map key relations, and design instruction with proper orientation, exercise, and feedback. Discusses the four guidelines and uses flow charts and diagrams to show how the…

  12. Statistical and Microscopic Approach to Gas Phase Chemical Kinetics.

    ERIC Educational Resources Information Center

    Perez, J. M.; Quereda, R.

    1983-01-01

    Describes advanced undergraduate laboratory exercise examining the dependence of the rate constants and the instantaneous concentrations with the nature and energy content in a gas-phase complex reaction. Computer program (with instructions and computation flow charts) used with the exercise is available from the author. (Author/JN)

  13. Ruggedness of 2D code printed on grain tracers for implementing a prospective grain traceability system to the bulk grain delivery system

    USDA-ARS?s Scientific Manuscript database

    Food-grade tracers were printed with two-dimensional Data Matrix (DM) barcode so that they could carry simulated identifying information about grain as part of a prospective traceability system. The key factor in evaluating the tracers was their ability to be read with a code scanner after being rem...

  14. Theater Blood Application Was Not Effectively Developed and Implemented

    DTIC Science & Technology

    2015-07-17

    blood product by unit; and • monitor non- Food and Drug Administration Blood Product Testing. The CONOPS document also identified over 400 specific...time of a transfusion. However, this requirement was not identified in the CONOPS document. Further, PEO DHCS officials provided a traceability ...the CONOPS document, requirements management database, and the traceability matrix increased the risk that the Theater Blood Application

  15. Food quality and safety: traceability and labeling.

    PubMed

    Lupien, John R

    2005-01-01

    This article discusses food systems in general, their development over the past 120 years, and realities and problems faced by a world population of over 6 billion people. Various food and feed problems are mentioned, and the concept of "traceability" is discussed in the context of the broader and more useful approach of using "good practices" at all levels of the food chain.

  16. Metrological Traceability in the Social Sciences: A Model from Reading Measurement

    NASA Astrophysics Data System (ADS)

    Stenner, A. Jackson; Fisher, William P., Jr.

    2013-09-01

    The central importance of reading ability in learning makes it the natural place to start in formative and summative assessments in education. The Lexile Framework for Reading constitutes a commercial metrological traceability network linking books, test results, instructional materials, and students in elementary and secondary English and Spanish language reading education in the U.S., Canada, Mexico, and Australia.

  17. Measurement uncertainty: Friend or foe?

    PubMed

    Infusino, Ilenia; Panteghini, Mauro

    2018-02-02

    The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Traceability information carriers. The technology backgrounds and consumers' perceptions of the technological solutions.

    PubMed

    Chrysochou, Polymeros; Chryssochoidis, George; Kehagia, Olga

    2009-12-01

    The implementation of traceability in the food supply chain has reinforced adoption of technologies with the ability to track forward and trace back product-related information. Based on the premise that these technologies can be used as a means to provide product-related information to consumers, this paper explores the perceived benefits and drawbacks of such technologies. The aim is to identify factors that influence consumers' perceptions of such technologies, and furthermore to advise the agri-food business on issues that they should consider prior to the implementation of such technologies in their production lines. For the purposes of the study, a focus group study was conducted across 12 European countries, while a set of four different technologies used as a means to provide traceability information to consumers was the focal point of the discussions in each focus group. Results show that the amount of and confidence in the information provided, perceived levels of convenience, impact on product quality and safety, impact on consumers' health and the environment, and potential consequences on ethical and privacy liberties constitute important factors influencing consumers' perceptions of technologies that provide traceability.

  19. Non-destructive geographical traceability of sea cucumber (Apostichopus japonicus) using near infrared spectroscopy combined with chemometric methods

    PubMed Central

    Cai, Rui; Wang, Shisheng; Tang, Bo; Li, Yueqing; Zhao, Weijie

    2018-01-01

    Sea cucumber is the major tonic seafood worldwide, and geographical origin traceability is an important part of its quality and safety control. In this work, a non-destructive method for origin traceability of sea cucumber (Apostichopus japonicus) from northern China Sea and East China Sea using near infrared spectroscopy (NIRS) and multivariate analysis methods was proposed. Total fat contents of 189 fresh sea cucumber samples were determined and partial least-squares (PLS) regression was used to establish the quantitative NIRS model. The ordered predictor selection algorithm was performed to select feasible wavelength regions for the construction of PLS and identification models. The identification model was developed by principal component analysis combined with Mahalanobis distance and scaling to the first range algorithms. In the test set of the optimum PLS models, the root mean square error of prediction was 0.45, and correlation coefficient was 0.90. The correct classification rates of 100% were obtained in both identification calibration model and test model. The overall results indicated that NIRS method combined with chemometric analysis was a suitable tool for origin traceability and identification of fresh sea cucumber samples from nine origins in China. PMID:29410795

  20. Non-destructive geographical traceability of sea cucumber (Apostichopus japonicus) using near infrared spectroscopy combined with chemometric methods.

    PubMed

    Guo, Xiuhan; Cai, Rui; Wang, Shisheng; Tang, Bo; Li, Yueqing; Zhao, Weijie

    2018-01-01

    Sea cucumber is the major tonic seafood worldwide, and geographical origin traceability is an important part of its quality and safety control. In this work, a non-destructive method for origin traceability of sea cucumber ( Apostichopus japonicus ) from northern China Sea and East China Sea using near infrared spectroscopy (NIRS) and multivariate analysis methods was proposed. Total fat contents of 189 fresh sea cucumber samples were determined and partial least-squares (PLS) regression was used to establish the quantitative NIRS model. The ordered predictor selection algorithm was performed to select feasible wavelength regions for the construction of PLS and identification models. The identification model was developed by principal component analysis combined with Mahalanobis distance and scaling to the first range algorithms. In the test set of the optimum PLS models, the root mean square error of prediction was 0.45, and correlation coefficient was 0.90. The correct classification rates of 100% were obtained in both identification calibration model and test model. The overall results indicated that NIRS method combined with chemometric analysis was a suitable tool for origin traceability and identification of fresh sea cucumber samples from nine origins in China.

  1. The Elimination of Transfer Distances Is an Important Part of Hospital Design.

    PubMed

    Karvonen, Sauli; Nordback, Isto; Elo, Jussi; Havulinna, Jouni; Laine, Heikki-Jussi

    2017-04-01

    The objective of the present study was to describe how a specific patient flow analysis with from-to charts can be used in hospital design and layout planning. As part of a large renewal project at a university hospital, a detailed patient flow analysis was applied to planning the musculoskeletal surgery unit (orthopedics and traumatology, hand surgery, and plastic surgery). First, the main activities of the unit were determined. Next, the routes of all patients treated over the course of 1 year were studied, and their physical movements in the current hospital were calculated. An ideal layout of the new hospital was then generated to minimize transfer distances by placing the main activities with close to each other, according to the patient flow analysis. The actual architectural design was based on the ideal layout plan. Finally, we compared the current transfer distances to the distances patients will move in the new hospital. The methods enabled us to estimate an approximate 50% reduction in transfer distances for inpatients (from 3,100 km/year to 1,600 km/year) and 30% reduction for outpatients (from 2,100 km/year to 1,400 km/year). Patient transfers are nonvalue-added activities. This study demonstrates that a detailed patient flow analysis with from-to charts can substantially shorten transfer distances, thereby minimizing extraneous patient and personnel movements. This reduction supports productivity improvement, cross-professional teamwork, and patient safety by placing all patient flow activities close to each other. Thus, this method is a valuable additional tool in hospital design.

  2. Importance of Calibration/Validation Traceability for Multi-Sensor Imaging Spectrometry Applications

    NASA Technical Reports Server (NTRS)

    Thome, K.

    2017-01-01

    Knowledge of calibration traceability is essential for ensuring the quality of data products relying on multiple sensors and especially true for imaging spectrometers. The current work discusses the expected impact that imaging spectrometers have in ensuring radiometric traceability for both multispectral and hyperspectral products. The Climate Absolute Radiance and Refractivity Observatory Pathfinder mission is used to show the role that high-accuracy imaging spectrometers can play in understanding test sites used for vicarious calibration of sensors. The associated Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer calibration demonstration system is used to illustrate recent advances in laboratory radiometric calibration approaches that will allow both the use of imaging spectrometers as calibration standards as well as to ensure the consistency of the multiple imaging spectrometers expected to be on orbit in the next decade.

  3. Decision Model for Planning and Scheduling of Seafood Product Considering Traceability

    NASA Astrophysics Data System (ADS)

    Agustin; Mawengkang, Herman; Mathelinea, Devy

    2018-01-01

    Due to the global challenges, it is necessary for an industrial company to integrate production scheduling and distribution planning, in order to be more efficient and to get more economics advantages. This paper presents seafood production planning and scheduling of a seafood manufacture company which produces simultaneously multi kind of seafood products, located at Aceh Province, Indonesia. The perishability nature of fish highly restricts its storage duration and delivery conditions. Traceability is a tracking requirement to check whether the quality of the product is satisfied. The production and distribution planning problem aims to meet customer demand subject to traceability of the seafood product and other restrictions. The problem is modeled as a mixed integer linear program, and then it is solved using neighborhood search approach.

  4. An intelligent traceability system: Efficient tool for a supply chain sustainability

    NASA Astrophysics Data System (ADS)

    Bougdira, Abdesselam; Ahaitouf, Abdelaziz; Akharraz, Ismail

    2016-07-01

    The supply chain sustainability becomes a necessity for a smooth, a rapid and a fluid economic transaction. To reach a sustainable supply chain, we propose to focus attention on products and their lifecycle. So, we consider the traceability as a major success key to ensure the supply chain sustainability. For that, we consider a supply chain design that use an intelligent products traced by an intelligent traceability system. This system identifies, restores history and properties of a product, besides it tracks, in real-time a product. This solution can, also, bring, in the product environment, appropriate adjustments to prevent any risk of threatening qualities for the product. So, it helps supply chain contributors making the sustainable adjustments and the instant benchmark of the supply chain sustainability.

  5. Sinus pericranii: diagnosis and management in 21 pediatric patients.

    PubMed

    Pavanello, Marco; Melloni, Ilaria; Antichi, Eleonora; Severino, Mariasavina; Ravegnani, Marcello; Piatelli, Gianluca; Cama, Armando; Rossi, Andrea; Gandolfo, Carlo

    2015-01-01

    Sinus pericranii (SP) is a rare venous anomaly abnormally connecting the intracranial dural sinuses with the epicranial veins. In the present study the authors aimed to clarify this clinicoradiological entity, define the role of angiography in its preoperative assessment, and suggest a diagnostic-therapeutic flow chart for management purposes. The authors retrospectively reviewed the clinical charts and neuroimages of 21 patients with SP. All patients underwent brain MRI, MR venography, and craniocerebral CT. Diagnostic digital subtraction angiography was performed in 19 of 21 patients, and the SPs were categorized as dominant (draining the majority of the intracranial venous outflow) or accessory (draining only a minority of the intracranial venous outflow). SP was median or paramedian in 20 patients and lateral in 1 patient. There were 5 dominant and 14 accessory SPs. The dominant SPs were not treated. Among the patients with accessory SP, 4 were not treated, 2 underwent surgical ligature, and 8 were treated endovascularly (with either transvenous or percutaneous embolization). No complications were observed, and symptoms disappeared after treatment in all cases. Accepted guidelines or recommendations concerning the management, diagnosis, and treatment of SP are still lacking. The authors define here a diagnostic-therapeutic flow chart, in which angiography plays a crucial role in the classification of SP and choice of the optimal treatment. Only accessory SP is amenable to treatment, whereas dominant SP must be preserved. The endovascular approach is becoming increasingly relevant and has proven to be safe and effective.

  6. A review of reporting of participant recruitment and retention in RCTs in six major journals

    PubMed Central

    Toerien, Merran; Brookes, Sara T; Metcalfe, Chris; de Salis, Isabel; Tomlin, Zelda; Peters, Tim J; Sterne, Jonathan; Donovan, Jenny L

    2009-01-01

    Background Poor recruitment and retention of participants in randomised controlled trials (RCTs) is problematic but common. Clear and detailed reporting of participant flow is essential to assess the generalisability and comparability of RCTs. Despite improved reporting since the implementation of the CONSORT statement, important problems remain. This paper aims: (i) to update and extend previous reviews evaluating reporting of participant recruitment and retention in RCTs; (ii) to quantify the level of participation throughout RCTs. Methods We reviewed all reports of RCTs of health care interventions and/or processes with individual randomisation, published July–December 2004 in six major journals. Short, secondary or interim reports, and Phase I/II trials were excluded. Data recorded were: general RCT details; inclusion of flow diagram; participant flow throughout trial; reasons for non-participation/withdrawal; target sample sizes. Results 133 reports were reviewed. Overall, 79% included a flow diagram, but over a third were incomplete. The majority reported the flow of participants at each stage of the trial after randomisation. However, 40% failed to report the numbers assessed for eligibility. Percentages of participants retained at each stage were high: for example, 90% of eligible individuals were randomised, and 93% of those randomised were outcome assessed. On average, trials met their sample size targets. However, there were some substantial shortfalls: for example 21% of trials reporting a sample size calculation failed to achieve adequate numbers at randomisation, and 48% at outcome assessment. Reporting of losses to follow up was variable and difficult to interpret. Conclusion The majority of RCTs reported the flow of participants well after randomisation, although only two-thirds included a complete flow chart and there was great variability over the definition of "lost to follow up". Reporting of participant eligibility was poor, making assessments of recruitment practice and external validity difficult. Reporting of participant flow throughout RCTs could be improved by small changes to the CONSORT chart. PMID:19591685

  7. A review of reporting of participant recruitment and retention in RCTs in six major journals.

    PubMed

    Toerien, Merran; Brookes, Sara T; Metcalfe, Chris; de Salis, Isabel; Tomlin, Zelda; Peters, Tim J; Sterne, Jonathan; Donovan, Jenny L

    2009-07-10

    Poor recruitment and retention of participants in randomised controlled trials (RCTs) is problematic but common. Clear and detailed reporting of participant flow is essential to assess the generalisability and comparability of RCTs. Despite improved reporting since the implementation of the CONSORT statement, important problems remain. This paper aims: (i) to update and extend previous reviews evaluating reporting of participant recruitment and retention in RCTs; (ii) to quantify the level of participation throughout RCTs. We reviewed all reports of RCTs of health care interventions and/or processes with individual randomisation, published July-December 2004 in six major journals. Short, secondary or interim reports, and Phase I/II trials were excluded. Data recorded were: general RCT details; inclusion of flow diagram; participant flow throughout trial; reasons for non-participation/withdrawal; target sample sizes. 133 reports were reviewed. Overall, 79% included a flow diagram, but over a third were incomplete. The majority reported the flow of participants at each stage of the trial after randomisation. However, 40% failed to report the numbers assessed for eligibility. Percentages of participants retained at each stage were high: for example, 90% of eligible individuals were randomised, and 93% of those randomised were outcome assessed. On average, trials met their sample size targets. However, there were some substantial shortfalls: for example 21% of trials reporting a sample size calculation failed to achieve adequate numbers at randomisation, and 48% at outcome assessment. Reporting of losses to follow up was variable and difficult to interpret. The majority of RCTs reported the flow of participants well after randomisation, although only two-thirds included a complete flow chart and there was great variability over the definition of "lost to follow up". Reporting of participant eligibility was poor, making assessments of recruitment practice and external validity difficult. Reporting of participant flow throughout RCTs could be improved by small changes to the CONSORT chart.

  8. Comparison of clast and matrix dispersal in till: Charlo-Atholville area, north-central New Brunswick

    USGS Publications Warehouse

    Dickson, M.L.; Broster, B.E.; Parkhill, M.A.

    2004-01-01

    Striations and dispersal patterns for till clasts and matrix geochemistry are used to define flow directions of glacial transport across an area of about 800km2 in the Charlo-Atholville area of north-central New Brunswick. A total of 170 clast samples and 328 till matrix samples collected for geochemical analysis across the region, were analyzed for a total of 39 elements. Major lithologic contacts used here to delineate till clast provenance were based on recent bedrock mapping. Eleven known mineral occurrences and a gossan are used to define point source targets for matrix geochemical dispersal trains and to estimate probable distance and direction of transport from unknown sources. Clast trains are traceable for distances of approximately 10 km, whereas till geochemical dispersal patterns are commonly lost within 5 km of transport. Most dispersal patterns reflect more than a single direction of glacial transport. These data indicate that a single till sheet, 1-4 m thick, was deposited as the dominant ice-flow direction fluctuated between southeastward, eastward, and northward over the study area. Directions of early flow represent changes in ice sheet dominance, first from the northwest and then from the west. Locally, eastward and northward flow represent the maximum erosive phases. The last directions of flow are likely due to late glacial ice sheet drawdown towards the valley outlet at Baie des Chaleurs.

  9. Multi-objective Operation Chart Optimization for Aquatic Species Habitat Conservation of Cascaded Hydropower System on Yuan River, Southwestern China

    NASA Astrophysics Data System (ADS)

    Wen, X.; Lei, X.; Fang, G.; Huang, X.

    2017-12-01

    Extensive cascading hydropower exploitation in southwestern China has been the subject of debate and conflict in recent years. Introducing limited ecological curves, a novel approach for derivation of hydropower-ecological joint operation chart of cascaded hydropower system was proposed, aiming to optimize the general hydropower and ecological benefits, and to alleviate the ecological deterioration in specific flood/dry conditions. The physical habitat simulation model is proposed initially to simulate the relationship between streamflow and physical habitat of target fish species and to determine the optimal ecological flow range of representative reach. The ecological—hydropower joint optimization model is established to produce the multi-objective operation chart of cascaded hydropower system. Finally, the limited ecological guiding curves were generated and added into the operation chart. The JS-MDS cascaded hydropower system on the Yuan River in southwestern China is employed as the research area. As the result, the proposed guiding curves could increase the hydropower production amount by 1.72% and 5.99% and optimize ecological conservation degree by 0.27% and 1.13% for JS and MDS Reservoir, respectively. Meanwhile, the ecological deterioration rate also sees a decrease from 6.11% to 1.11% for JS Reservoir and 26.67% to 3.89% for MDS Reservoir.

  10. NIST-Traceable NMR Method to Determine Quantitative Weight Percentage Purity of Mustard (HD) Feedstock Samples

    DTIC Science & Technology

    2018-01-01

    ECBC-TR-1506 NIST-TRACEABLE NMR METHOD TO DETERMINE QUANTITATIVE WEIGHT PERCENTAGE PURITY OF MUSTARD (HD) FEEDSTOCK SAMPLES David J...McGarvey RESEARCH AND TECHNOLOGY DIRECTORATE William R. Creasy LEIDOS, INC. Abingdon, MD 21009-1261 Theresa R. Connell EXCET, INC...be construed as an official Department of the Army position unless so designated by other authorizing documents. REPORT DOCUMENTATION PAGE

  11. Cryogenic flow rate measurement with a laser Doppler velocimetry standard

    NASA Astrophysics Data System (ADS)

    Maury, R.; Strzelecki, A.; Auclercq, C.; Lehot, Y.; Loubat, S.; Chevalier, J.; Ben Rayana, F.

    2018-03-01

    A very promising alternative to the state-of-the-art static volume measurements for liquefied natural gas (LNG) custody transfer processes is the dynamic principle of flow metering. As the Designated Institute (DI) of the LNE (‘Laboratoire National de métrologie et d’Essais’, being the French National Metrology Institute) for high-pressure gas flow metering, Cesame-Exadebit is involved in various research and development programs. Within the framework of the first (2010-2013) and second (2014-2017) EURAMET Joint Research Project (JRP), named ‘Metrological support for LNG custody transfer and transport fuel applications’, Cesame-Exadebit explored a novel cryogenic flow metering technology using laser Doppler velocimetry (LDV) as an alternative to ultrasonic and Coriolis flow metering. Cesame-Exadebit is trying to develop this technique as a primary standard for cryogenic flow meters. Currently, cryogenic flow meters are calibrated at ambient temperatures with water. Results are then extrapolated to be in the Reynolds number range of real applications. The LDV standard offers a unique capability to perform online calibration of cryogenic flow meters in real conditions (temperature, pressure, piping and real flow disturbances). The primary reference has been tested on an industrial process in a LNG terminal during truck refuelling. The reference can calibrate Coriolis flow meters being used daily with all the real environmental constraints, and its utilisation is transparent for LNG terminal operators. The standard is traceable to Standard International units and the combined extended uncertainties have been determined and estimated to be lower than 0.6% (an ongoing improvement to reducing the correlation function uncertainty, which has a major impact in the uncertainty estimation).

  12. Estimated United States Transportation Energy Use 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C A; Simon, A J; Belles, R D

    A flow chart depicting energy flow in the transportation sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 31,000 trillion British Thermal Units (trBTUs) of energy were used throughout the United States in transportation activities. Vehicles used in these activities include automobiles, motorcycles, trucks, buses, airplanes, rail, and ships. The transportation sector is powered primarily by petroleum-derived fuels (gasoline, diesel and jet fuel). Biomass-derived fuels, electricity and natural gas-derived fuels are also used. The flow patterns represent a comprehensive systems view of energy used within themore » transportation sector.« less

  13. The application of compound-specific isotope analysis of fatty acids for traceability of sea cucumber (Apostichopus japonicus) in the coastal areas of China.

    PubMed

    Liu, Yu; Zhang, Xufeng; Li, Ying; Wang, Haixia

    2017-11-01

    Geographical origin traceability is an important issue for controlling the quality of seafood and safeguarding the interest of consumers. In the present study, a new method of compound-specific isotope analysis (CSIA) of fatty acids was established to evaluate its applicability in establishing the origin traceability of Apostichopus japonicus in the coastal areas of China. Moreover, principal component analysis (PCA) and discriminant analysis (DA) were applied to distinguish between the origins of A. japonicus. The results show that the stable carbon isotope compositions of fatty acids of A. japonicus significantly differ in terms of both season and origin. They also indicate that the stable carbon isotope composition of fatty acids could effectively discriminate between the origins of A. japonicus, except for between Changhai Island and Zhangzi Island in the spring of 2016 because of geographical proximity or the similarity of food sources. The fatty acids that have the highest contribution to identifying the geographical origins of A. japonicus are C22:6n-3, C16:1n-7, C20:5n-3, C18:0 and C23:1n-9, when considering the fatty acid contents, the stable carbon isotope composition of fatty acids and the results of the PCA and DA. We conclude that CSIA of fatty acids, combined with multivariate statistical analysis such as PCA and DA, may be an effective tool for establishing the traceability of A. japonicus in the coastal areas of China. The relevant conclusions of the present study provide a new method for determining the traceability of seafood or other food products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Evaluating droplet digital PCR for the quantification of human genomic DNA: converting copies per nanoliter to nanograms nuclear DNA per microliter.

    PubMed

    Duewer, David L; Kline, Margaret C; Romsos, Erica L; Toman, Blaza

    2018-05-01

    The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference. We have shown that droplet digital PCR (ddPCR) limiting dilution end-point measurements of the concentration of DNA copies per volume of sample can be traceably linked to the International System of Units (SI). Unlike values assigned using conventional relationships between ultraviolet absorbance and DNA mass concentration, entity-based ddPCR measurements are expected to be stable over time. However, the forensic community expects DNA quantity to be stated in terms of mass concentration rather than entity concentration. The transformation can be accomplished given SI-traceable values and uncertainties for the number of nucleotide bases per human haploid genome equivalent (HHGE) and the average molar mass of a nucleotide monomer in the DNA polymer. This report presents the considerations required to establish the metrological traceability of ddPCR-based mass concentration estimates of human nuclear DNA. Graphical abstract The roots of metrological traceability for human nuclear DNA mass concentration results. Values for the factors in blue must be established experimentally. Values for the factors in red have been established from authoritative source materials. HHGE stands for "haploid human genome equivalent"; there are two HHGE per diploid human genome.

  15. Application of the Reference Method Isotope Dilution Gas Chromatography Mass Spectrometry (ID/GC/MS) to Establish Metrological Traceability for Calibration and Control of Blood Glucose Test Systems

    PubMed Central

    Andreis, Elisabeth; Küllmer, Kai

    2014-01-01

    Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. PMID:24876614

  16. Nomenclature and traceability debate for biosimilars: small-molecule surrogates lend support for distinguishable nonproprietary names.

    PubMed

    Chao, Jingdong; Skup, Martha; Alexander, Emily; Tundia, Namita; Macaulay, Dendy; Wu, Eric; Mulani, Parvez

    2015-03-01

    The purpose of the present study was to investigate the traceability of adverse events (AEs) for branded and generic drugs with identical nonproprietary names and to consider potential implications for the traceability of AEs for branded and biosimilar biologics. Adverse event reports in the Food and Drug Administration AE Reporting System (FAERS) were compared with those in a commercial insurance claims database (Truven Health MarketScan(®)) for 2 drugs (levetiracetam and enoxaparin sodium) with manufacturing or prescribing considerations potentially analogous to those of some biosimilars. Monthly rates of branded- and generic-attributed AEs were estimated pre- and post-generic entry. Post-entry branded-to-generic AE relative rate ratios were calculated. In FAERS, monthly AE rate ratios during the post-generic period showed a pattern in which AE rates for the branded products were greater than for the generic products. Differences in rates of brand- and generic-attributed AEs were statistically significant for both study drugs; the AE rate for the branded products peaked at approximately 10 times that of the generic levetiracetam products and approximately 4 times that of the generic enoxaparin sodium products. In contrast, monthly ratios for the MarketScan data were relatively constant over time. Use of the same nonproprietary name for generic and branded products may contribute to poor traceability of AEs reported in the FAERS database due to the significant misattribution of AEs to branded products (when those AEs were in fact associated with patient use of generic products). To ensure accurate and robust safety surveillance and traceability for biosimilar products in the United States, improved product identification mechanisms, such as related but distinguishable nonproprietary names for biosimilars and reference biologics, should be considered.

  17. A methodology for obtaining on-orbit SI-traceable spectral radiance measurements in the thermal infrared

    NASA Astrophysics Data System (ADS)

    Dykema, John A.; Anderson, James G.

    2006-06-01

    A methodology to achieve spectral thermal radiance measurements from space with demonstrable on-orbit traceability to the International System of Units (SI) is described. This technique results in measurements of infrared spectral radiance R(\\tilde {\\upsilon }) , with spectral index \\tilde {\\upsilon } in cm-1, with a relative combined uncertainty u_c[R(\\tilde {\\upsilon })] of 0.0015 (k = 1) for the average mid-infrared radiance emitted by the Earth. This combined uncertainty, expressed in brightness temperature units, is equivalent to ±0.1 K at 250 K at 750 cm-1. This measurement goal is achieved by utilizing a new method for infrared scale realization combined with an instrument design optimized to minimize component uncertainties and admit tests of radiometric performance. The SI traceability of the instrument scale is established by evaluation against source-based and detector-based infrared scales in defined laboratory protocols before launch. A novel strategy is executed to ensure fidelity of on-orbit calibration to the pre-launch scale. This strategy for on-orbit validation relies on the overdetermination of instrument calibration. The pre-launch calibration against scales derived from physically independent paths to the base SI units provides the foundation for a critical analysis of the overdetermined on-orbit calibration to establish an SI-traceable estimate of the combined measurement uncertainty. Redundant calibration sources and built-in diagnostic tests to assess component measurement uncertainties verify the SI traceability of the instrument calibration over the mission lifetime. This measurement strategy can be realized by a practical instrument, a prototype Fourier-transform spectrometer under development for deployment on a small satellite. The measurement record resulting from the methodology described here meets the observational requirements for climate monitoring and climate model testing and improvement.

  18. Knowledge, attitudes and practices of traceability among livestock traders in south-western Nigeria: implications for sustainable livestock industry.

    PubMed

    Adesokan, Hezekiah K; Ocheja, Samuel E

    2014-01-01

    Livestock diseases and other animal health events are a threat to achieving sustainable livestock industry. The knowledge of trace-back and the practice of providing feedback on diseases encountered in slaughtered animals from the abattoir to the farm can help limit the spread as well as manage potential future incidents of such diseases. We assessed the knowledge, attitudes and practices of 200 willing livestock traders on traceability in Bodija Municipal Abattoir, south-western Nigeria. The results reveal that the majority of these traders had poor knowledge (79.5 %) and practices (74.0 %) of traceability, though 89.5 % demonstrated good attitudes. While 22.9 % knew that traceability could be an effective means to control diseases, only a lower proportion (9.0 %) knew the health status of the animals being purchased. Though 29.0 % reported the diseases encountered in their animals during slaughter to the farm, only 9.5 % followed up to ensure the farmers take steps at preventing further occurrence of the reported diseases. While age (p = 0.000; 0.014) and education (p = 0.000; 0.000) were both significant for good knowledge and attitudes, frequency of condemned cases (p = 0.000) and length of years in the trade (p = 0.004) were, respectively, significant for good knowledge and attitudes with none associated with practice. These poor levels of knowledge and practices of traceability are a threat to sustainable livestock industry, food security and human health; hence, there is an urgent need to institute national feedback mechanism on slaughtered animals in order to strengthen interventions against diseases at farm levels.

  19. Compliance Timeline and Applicability Determination for Paper and Other Web Coating National Emission Standards for Hazardous Air Pollutants (NESHAP)

    EPA Pesticide Factsheets

    This February 2003 document contains a diagram of dates and events for compliance with the NESHAP for Paper and Other Web Coating. Also on this page is an April 2004 flow chart to determine if the NESHAP applies to your facility.

  20. SRM Manual, Selected Resource Materials: Description and Evaluation.

    ERIC Educational Resources Information Center

    Alberta Dept. of Education, Edmonton. Special Educational Services Branch.

    Provided in the manual is descriptive and evaluative information on 67 instructional materials or programs frequently used with exceptional children in Alberta schools. A flow chart describes the three methods of using the manual: l) to obtain descriptive and evaluative information of an instruction program in the manual 2) to classify and record…

  1. Decision Support Systems: Applications in Statistics and Hypothesis Testing.

    ERIC Educational Resources Information Center

    Olsen, Christopher R.; Bozeman, William C.

    1988-01-01

    Discussion of the selection of appropriate statistical procedures by educators highlights a study conducted to investigate the effectiveness of decision aids in facilitating the use of appropriate statistics. Experimental groups and a control group using a printed flow chart, a computer-based decision aid, and a standard text are described. (11…

  2. STEADY-STATE DESIGN OF VERTICAL WELLS FOR LIQUIDS ADDITION AT BIOREACTOR LANDFILLS

    EPA Science Inventory

    This paper presents design charts that a landfill engineer can use for the design of a vertical well system for liquids addition at bioreactor landfills. The flow rate and lateral and vertical zones of impact of a vertical well were estimated as a function of input variables su...

  3. A Computer Course for Business Students: Teacher's Guide.

    ERIC Educational Resources Information Center

    Waterhouse, Ann

    This teacher's guide is for a course designed to teach business students the fundamentals of the BASIC language and computer programming using a series of business-oriented programs. Each lesson contains an introduction, flow charts, and computer programs. The six lesson topics are print-out and format control, count-average, withholding tax…

  4. 49 CFR 173.124 - Class 4, Divisions 4.1, 4.2 and 4.3-Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... material must be determined using the testing protocol from Figure 14.2 (Flow Chart for Assigning Self... HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS... Assignments and Exceptions for Hazardous Materials Other Than Class 1 and Class 7 § 173.124 Class 4, Divisions...

  5. Biochemical Evolution of Iron and Copper Proteins, Substances Vital to Life

    ERIC Educational Resources Information Center

    Frieden, Earl

    1974-01-01

    Summarizes studies in the area of biochemical evolution of iron, copper, and heme proteins to provide an historical outline. Included are lists of major kinds of proteins and enzymes and charts illustrating electron flow in a cytochrome electron transport system and interconversion of jerrous to ferric ion in iron metabolism. (CC)

  6. An Improved Qualitative Analysis Procedure for Aluminum Subgroup Cations.

    ERIC Educational Resources Information Center

    Kistner, C. R.; Robinson, Patricia J.

    1983-01-01

    Describes a procedure for the qualitative analysis of aluminum subgroup cations designed to avoid failure to obtain lead or barium chromate precipitates or failure to report aluminum hydroxide when present (due to staining). Provides a flow chart and step-by-step explanation for the new procedure, indicating significantly improved student results.…

  7. Johnson-O'Malley Annual Report, Fiscal Year 1972.

    ERIC Educational Resources Information Center

    Bureau of Indian Affairs (Dept. of Interior), Washington, DC.

    Presenting narrative and tabular data re: American Indians and the Johnson-O'Malley Program, this 1972 annual report includes the following: an introduction to the JOM Program; 1972 program participation by states and districts; an historical synopsis of the JOM Program; a map of the JOM administrative areas; a flow chart depicting JOM…

  8. Installation Restoration Program. Phase I: Records Search Willow Grove Air Reserve Facility, Willow Grove, Pennsylvania.

    DTIC Science & Technology

    1984-11-01

    FLOW CHART Complet List of Location/Shtes Evaluation of Past Operations at LUste SNMe * ~Potential Hazard to Healh WelareS Reglaor Agencon consolidat...siting studies were also a part of this tions, soil, groundwater sampling and large complex project. analysis, and remedial concept engi- neering. Project

  9. Feasibility study of an Integrated Program for Aerospace-vehicle Design (IPAD) system. Volume 3: Engineering creative/evaluation processes, phase 1, task 2

    NASA Technical Reports Server (NTRS)

    Garrocq, C. A.; Hosek, J. J.

    1973-01-01

    A series of functional flow charts are considered that were developed to properly identify and record the degree of participation of the disciplines considered in this feasibility study and the type of data required in the design process.

  10. 19 CFR Appendix B to Part 191 - Sample Formats for Applications for Specific Manufacturing Drawback Rulings

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... When applicable, give equations of the chemical reactions. The attachment of a flow chart in addition... measurement of the merchandise used. This loss or gain is caused by atmospheric conditions, chemical reactions... finished article is intended. When applicable, give equations of the chemical reactions. The attachment of...

  11. 19 CFR Appendix B to Part 191 - Sample Formats for Applications for Specific Manufacturing Drawback Rulings

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... When applicable, give equations of the chemical reactions. The attachment of a flow chart in addition... measurement of the merchandise used. This loss or gain is caused by atmospheric conditions, chemical reactions... finished article is intended. When applicable, give equations of the chemical reactions. The attachment of...

  12. 19 CFR Appendix B to Part 191 - Sample Formats for Applications for Specific Manufacturing Drawback Rulings

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... When applicable, give equations of the chemical reactions. The attachment of a flow chart in addition... measurement of the merchandise used. This loss or gain is caused by atmospheric conditions, chemical reactions... finished article is intended. When applicable, give equations of the chemical reactions. The attachment of...

  13. Advanced Electronics. Curriculum Development. Bulletin 1778.

    ERIC Educational Resources Information Center

    Eppler, Thomas

    This document is a curriculum guide for a 180-hour course in advanced electronics for 11th and 12th grades that has four instructional units. The instructional units are orientation, discrete components, integrated circuits, and electronic systems. The document includes a course flow chart; a two-page section that describes the course, lists…

  14. 75 FR 59411 - Defense Federal Acquisition Regulation Supplement; Patents, Data, and Copyrights (DFARS Case 2010...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-27

    ....'' The items ``design details, algorithms, processes, flow charts, formulas, and related material that describe the design, organization, or structure'' of computer software had been added to the current... 252.227-7018, which serves as the post-award complement to the pre-award identification and assertion...

  15. Schedule Risk Assessment

    NASA Technical Reports Server (NTRS)

    Smith, Greg

    2003-01-01

    Schedule risk assessments determine the likelihood of finishing on time. Each task in a schedule has a varying degree of probability of being finished on time. A schedule risk assessment quantifies these probabilities by assigning values to each task. This viewgraph presentation contains a flow chart for conducting a schedule risk assessment, and profiles applicable several methods of data analysis.

  16. Assistive Technology for Students with Mild Disabilities: Update 2002. ERIC Digest.

    ERIC Educational Resources Information Center

    Behrmann, Michael; Jerome, Marci Kinas

    This digest discusses six identified areas of instruction in which assistive technology can aid students with mild disabilities. It begins by discussing how assistive technology can help the student's organization. Low-tech solutions are explained, including teaching students to organize their thoughts or work using flow-charting, task analysis,…

  17. Human Behavior Based Exploratory Model for Successful Implementation of Lean Enterprise in Industry

    ERIC Educational Resources Information Center

    Sawhney, Rupy; Chason, Stewart

    2005-01-01

    Currently available Lean tools such as Lean Assessments, Value Stream Mapping, and Process Flow Charting focus on system requirements and overlook human behavior. A need is felt for a tool that allows one to baseline personnel, determine personnel requirements and align system requirements with personnel requirements. Our exploratory model--The…

  18. ROMPS critical design review. Volume 2: Robot module design documentation

    NASA Technical Reports Server (NTRS)

    Dobbs, M. E.

    1992-01-01

    The robot module design documentation for the Remote Operated Materials Processing in Space (ROMPS) experiment is compiled. This volume presents the following information: robot module modifications; Easylab commands definitions and flowcharts; Easylab program definitions and flowcharts; robot module fault conditions and structure charts; and C-DOC flow structure and cross references.

  19. Comparison of infusion pumps calibration methods

    NASA Astrophysics Data System (ADS)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  20. Flow-Field Surveys for Rectangular Nozzles. Supplement

    NASA Technical Reports Server (NTRS)

    Zaman, K. B. M. Q.

    2012-01-01

    Flow field survey results for three rectangular nozzles are presented for a low subsonic condition obtained primarily by hot-wire anemometry. The three nozzles have aspect ratios of 2:1, 4:1 and 8:1. A fourth case included has 2:1 aspect ratio with chevrons added to the long edges. Data on mean velocity, turbulent normal and shear stresses as well as streamwise vorticity are presented covering a streamwise distance up to sixteen equivalent diameters from the nozzle exit. These detailed flow properties, including initial boundary layer characteristics, are usually difficult to measure in high speed flows and the primary objective of the study is to aid ongoing and future computational and noise modeling efforts. This supplement contains data files, charts and source code.

  1. Flow field analysis of aircraft configurations using a numerical solution to the three-dimensional unified supersonic/hypersonic small disturbance equations, part 1

    NASA Technical Reports Server (NTRS)

    Gunness, R. C., Jr.; Knight, C. J.; Dsylva, E.

    1972-01-01

    The unified small disturbance equations are numerically solved using the well-known Lax-Wendroff finite difference technique. The method allows complete determination of the inviscid flow field and surface properties as long as the flow remains supersonic. Shock waves and other discontinuities are accounted for implicity in the numerical method. This technique was programed for general application to the three-dimensional case. The validity of the method is demonstrated by calculations on cones, axisymmetric bodies, lifting bodies, delta wings, and a conical wing/body combination. Part 1 contains the discussion of problem development and results of the study. Part 2 contains flow charts, subroutine descriptions, and a listing of the computer program.

  2. Implementing traceability using particle randomness-based textile printed tags

    NASA Astrophysics Data System (ADS)

    Agrawal, T. K.; Koehl, L.; Campagne, C.

    2017-10-01

    This article introduces a random particle-based traceability tag for textiles. The proposed tag not only act as a unique signature for the corresponding textile product but also possess the features such as easy to manufacture and hard to copy. It seeks applications in brand authentication and traceability in textile and clothing (T&C) supply chain. A prototype has been developed by screen printing process, in which micron-scale particles were mixed with the printing paste and printed on cotton fabrics to attain required randomness. To encode the randomness, the image of the developed tag was taken and analyzed using image processing. The randomness of the particles acts as a product key or unique signature which is required to decode the tag. Finally, washing and abrasion resistance tests were conducted to check the durability of the printed tag.

  3. [Preliminary studies on critical control point of traceability system in wolfberry].

    PubMed

    Liu, Sai; Xu, Chang-Qing; Li, Jian-Ling; Lin, Chen; Xu, Rong; Qiao, Hai-Li; Guo, Kun; Chen, Jun

    2016-07-01

    As a traditional Chinese medicine, wolfberry (Lycium barbarum) has a long cultivation history and a good industrial development foundation. With the development of wolfberry production, the expansion of cultivation area and the increased attention of governments and consumers on food safety, the quality and safety requirement of wolfberry is higher demanded. The quality tracing and traceability system of production entire processes is the important technology tools to protect the wolfberry safety, and to maintain sustained and healthy development of the wolfberry industry. Thus, this article analyzed the wolfberry quality management from the actual situation, the safety hazard sources were discussed according to the HACCP (hazard analysis and critical control point) and GAP (good agricultural practice for Chinese crude drugs), and to provide a reference for the traceability system of wolfberry. Copyright© by the Chinese Pharmaceutical Association.

  4. Traceability in stem cell research: from participant sample to induced pluripotent stem cell and back.

    PubMed

    Morrison, Michael; Moraia, Linda Briceño; Steele, Jane C

    2016-01-01

    This paper describes a traceability system developed for the Stem cells for Biological Assays of Novel drugs and prediCtive toxiCology consortium. The system combines records and labels that to biological material across geographical locations and scientific processes from sample donation to induced pluripotent stem cell line. The labeling system uses a unique identification number to link every aliquot of sample at every stage of the reprogramming pathway back to the original donor. Only staff at the clinical recruitment site can reconnect the unique identification number to the identifying details of a specific donor. This ensures the system meets ethical and legal requirements for protecting privacy while allowing full traceability of biological material. The system can be adapted to other projects and for use with different primary sample types.

  5. Services of the CDRH X-ray calibration laboratory and their traceability to National Standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerra, F.; Heaton, H.T.

    The X-ray Calibration Laboratory (XCL) of the Center for Devices and Radiological Health (CDRH) provides calibration services for the Food and Drug Administration (FDA). The instruments calibrated are used by FDA and contract state inspectors to verify compliance with federal x-ray performance standards and for national surveys of x-ray trends. In order to provide traceability of measurements, the CDRH XCL is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP) for reference, diagnostic, and x-ray survey instrument calibrations. In addition to these accredited services, the CDRH XCL also calibrates non-invasive kVp meters in single- and three-phase x-ray beams, and thermoluminescentmore » dosimeter (TLD) chips used to measure CT beam profiles. The poster illustrates these services and shows the traceability links back to the National Standards.« less

  6. Traceable measurements of small forces and local mechanical properties

    NASA Astrophysics Data System (ADS)

    Campbellová, Anna; Valtr, Miroslav; Zůda, Jaroslav; Klapetek, Petr

    2011-09-01

    Measurement of local mechanical properties is an important topic in the fields of nanoscale device fabrication, thin film deposition and composite material development. Nanoindentation instruments are commonly used to study hardness and related mechanical properties at the nanoscale. However, traceability and uncertainty aspects of the measurement process often remain left aside. In this contribution, the use of a commercial nanoindentation instrument for metrology purposes will be discussed. Full instrument traceability, provided using atomic force microscope cantilevers and a mass comparator (normal force), interferometer (depth) and atomic force microscope (area function) is described. The uncertainty of the loading/unloading curve measurements will be analyzed and the resulting uncertainties for quantities, that are computed from loading curves such as hardness or elastic modulus, are studied. For this calculation a combination of uncertainty propagation law and Monte Carlo uncertainty evaluations are used.

  7. Traceability validation of a high speed short-pulse testing method used in LED production

    NASA Astrophysics Data System (ADS)

    Revtova, Elena; Vuelban, Edgar Moreno; Zhao, Dongsheng; Brenkman, Jacques; Ulden, Henk

    2017-12-01

    Industrial processes of LED (light-emitting diode) production include LED light output performance testing. Most of them are monitored and controlled by optically, electrically and thermally measuring LEDs by high speed short-pulse measurement methods. However, these are not standardized and a lot of information is proprietary that it is impossible for third parties, such as NMIs, to trace and validate. It is known, that these techniques have traceability issue and metrological inadequacies. Often due to these, the claimed performance specifications of LEDs are overstated, which consequently results to manufacturers experiencing customers' dissatisfaction and a large percentage of failures in daily use of LEDs. In this research a traceable setup is developed to validate one of the high speed testing techniques, investigate inadequacies and work out the traceability issues. A well-characterised short square pulse of 25 ms is applied to chip-on-board (CoB) LED modules to investigate the light output and colour content. We conclude that the short-pulse method is very efficient in case a well-defined electrical current pulse is applied and the stabilization time of the device is "a priori" accurately determined. No colour shift is observed. The largest contributors to the measurement uncertainty include badly-defined current pulse and inaccurate calibration factor.

  8. A study of the factors that influence consumer attitudes toward beef products using the conjoint market analysis tool.

    PubMed

    Mennecke, B E; Townsend, A M; Hayes, D J; Lonergan, S M

    2007-10-01

    This study utilizes an analysis technique commonly used in marketing, the conjoint analysis method, to examine the relative utilities of a set of beef steak characteristics considered by a national sample of 1,432 US consumers, as well as additional localized samples representing undergraduate students at a business college and in an animal science department. The analyses indicate that among all respondents, region of origin is by far the most important characteristic; this is followed by animal breed, traceability, animal feed, and beef quality. Alternatively, the cost of cut, farm ownership, the use (or nonuse) of growth promoters, and whether the product is guaranteed tender were the least important factors. Results for animal science undergraduates are similar to the aggregate results, except that these students emphasized beef quality at the expense of traceability and the nonuse of growth promoters. Business students also emphasized region of origin but then emphasized traceability and cost. The ideal steak for the national sample is from a locally produced, choice Angus fed a mixture of grain and grass that is traceable to the farm of origin. If the product was not produced locally, respondents indicated that their preferred production states are, in order from most to least preferred, Iowa, Texas, Nebraska, and Kansas.

  9. Thermodynamic Temperature of High-Temperature Fixed Points Traceable to Blackbody Radiation and Synchrotron Radiation

    NASA Astrophysics Data System (ADS)

    Wähmer, M.; Anhalt, K.; Hollandt, J.; Klein, R.; Taubert, R. D.; Thornagel, R.; Ulm, G.; Gavrilov, V.; Grigoryeva, I.; Khlevnoy, B.; Sapritsky, V.

    2017-10-01

    Absolute spectral radiometry is currently the only established primary thermometric method for the temperature range above 1300 K. Up to now, the ongoing improvements of high-temperature fixed points and their formal implementation into an improved temperature scale with the mise en pratique for the definition of the kelvin, rely solely on single-wavelength absolute radiometry traceable to the cryogenic radiometer. Two alternative primary thermometric methods, yielding comparable or possibly even smaller uncertainties, have been proposed in the literature. They use ratios of irradiances to determine the thermodynamic temperature traceable to blackbody radiation and synchrotron radiation. At PTB, a project has been established in cooperation with VNIIOFI to use, for the first time, all three methods simultaneously for the determination of the phase transition temperatures of high-temperature fixed points. For this, a dedicated four-wavelengths ratio filter radiometer was developed. With all three thermometric methods performed independently and in parallel, we aim to compare the potential and practical limitations of all three methods, disclose possibly undetected systematic effects of each method and thereby confirm or improve the previous measurements traceable to the cryogenic radiometer. This will give further and independent confidence in the thermodynamic temperature determination of the high-temperature fixed point's phase transitions.

  10. Traceable calibration and demonstration of a portable dynamic force transfer standard

    NASA Astrophysics Data System (ADS)

    Vlajic, Nicholas; Chijioke, Ako

    2017-08-01

    In general, the dynamic sensitivity of a force transducer depends upon the mechanical system in which it is used. This dependence serves as motivation to develop a dynamic force transfer standard, which can be used to calibrate an application transducer in situ. In this work, we SI-traceably calibrate a hand-held force transducer, namely an impact hammer, by using a mass suspended from a thin line which is cut to produce a known dynamic force in the form of a step function. We show that this instrument is a promising candidate as a transfer standard, since its dynamic response has small variance between different users. This calibrated transfer standard is then used to calibrate a secondary force transducer in an example application setting. The combined standard uncertainty (k  =  2) in the calibration of the transfer standard was determined to be 2.1% or less, up to a bandwidth of 5 kHz. The combined standard uncertainty (k  =  2) in the performed transfer calibration was less than 4%, up to 3 kHz. An advantage of the transfer calibration framework presented here, is that the transfer standard can be used to transfer SI-traceable calibrations without the use of any SI-traceable voltage metrology instrumentation.

  11. Establishing the traceability of a uranyl nitrate solution to a standard reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, C.H.; Clark, J.P.

    1978-01-01

    A uranyl nitrate solution for use as a Working Calibration and Test Material (WCTM) was characterized, using a statistically designed procedure to document traceability to National Bureau of Standards Reference Material (SPM-960). A Reference Calibration and Test Material (PCTM) was prepared from SRM-960 uranium metal to approximate the acid and uranium concentration of the WCTM. This solution was used in the characterization procedure. Details of preparing, handling, and packaging these solutions are covered. Two outside laboratories, each having measurement expertise using a different analytical method, were selected to measure both solutions according to the procedure for characterizing the WCTM. Twomore » different methods were also used for the in-house characterization work. All analytical results were tested for statistical agreement before the WCTM concentration and limit of error values were calculated. A concentration value was determined with a relative limit of error (RLE) of approximately 0.03% which was better than the target RLE of 0.08%. The use of this working material eliminates the expense of using SRMs to fulfill traceability requirements for uranium measurements on this type material. Several years' supply of uranyl nitrate solution with NBS traceability was produced. The cost of this material was less than 10% of an equal quantity of SRM-960 uranium metal.« less

  12. Research Electronic Data Capture (REDCap®) used as an audit tool with a built-in database.

    PubMed

    Kragelund, Signe H; Kjærsgaard, Mona; Jensen-Fangel, Søren; Leth, Rita A; Ank, Nina

    2018-05-01

    The aim of this study was to develop an audit tool with a built-in database using Research Electronic Data Capture (REDCap®) as part of an antimicrobial stewardship program at a regional hospital in the Central Denmark Region, and to analyse the need, if any, to involve more than one expert in the evaluation of cases of antimicrobial treatment, and the level of agreement among the experts. Patients treated with systemic antimicrobials in the period from 1 September 2015 to 31 August 2016 were included, in total 722 cases. Data were collected retrospectively and entered manually. The audit was based on seven flow charts regarding: (1) initiation of antimicrobial treatment (2) infection (3) prescription and administration of antimicrobials (4) discontinuation of antimicrobials (5) reassessment within 48 h after the first prescription of antimicrobials (6) microbiological sampling in the period between suspicion of infection and the first administration of antimicrobials (7) microbiological results. The audit was based on automatic calculations drawing on the entered data and on expert assessments. Initially, two experts completed the audit, and in the cases in which they disagreed, a third expert was consulted. In 31.9% of the cases, the two experts agreed on all elements of the audit. In 66.2%, the two experts reached agreement by discussing the cases. Finally, 1.9% of the cases were completed in cooperation with a third expert. The experts assessed 3406 flow charts of which they agreed on 75.8%. We succeeded in creating an audit tool with a built-in database that facilitates independent expert evaluation using REDCap. We found a large inter-observer difference that needs to be considered when constructing a project based on expert judgements. Our two experts agreed on most of the flow charts after discussion, whereas the third expert's intervention did not have any influence on the overall assessment. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. A Review of Recruitment, Adherence and Drop-Out Rates in Omega-3 Polyunsaturated Fatty Acid Supplementation Trials in Children and Adolescents.

    PubMed

    van der Wurff, Inge S M; Meyer, Barbara J; de Groot, Renate H M

    2017-05-10

    The influence of n -3 long-chain polyunsaturated fatty acids ( n -3 LCPUFA) supplementation on health outcomes has been studied extensively with randomized controlled trials (RCT). In many research fields, difficulties with recruitment, adherence and high drop-out rates have been reported. However, what is unknown is how common these problems are in n -3 LCPUFA supplementation studies in children and adolescents. Therefore, this paper will review n -3 LCPUFA supplementation studies in children and adolescents with regard to recruitment, adherence and drop-out rates. The Web of Science, PubMed and Ovid databases were searched for papers reporting on RCT supplementing children and adolescents (2-18 years) with a form of n -3 LCPUFA (or placebo) for at least four weeks. As a proxy for abiding to CONSORT guidelines, we noted whether manuscripts provided a flow-chart and provided dates defining the period of recruitment and follow-up. Ninety manuscripts (reporting on 75 studies) met the inclusion criteria. The majority of the studies did not abide by the CONSORT guidelines: 55% did not provide a flow-chart, while 70% did not provide dates. The majority of studies provided minimal details about the recruitment process. Only 25 of the 75 studies reported an adherence rate which was on average 85%. Sixty-five of the 75 studies included drop-out rates which were on average 17%. Less than half of the included studies abided by the CONSORT guidelines (45% included a flow chart, while 30% reported dates). Problems with recruitment and drop-out seem to be common in n -3 LCPUFA supplementation trials in children and adolescents. However, reporting about recruitment, adherence and dropout rates was very heterogeneous and minimal in the included studies. Some techniques to improve recruitment, adherence and dropout rates were identified from the literature, however these techniques may need to be tailored to n -3 LCPUFA supplementation studies in children and adolescents.

  14. Scaling of Two-Phase Flows to Partial-Earth Gravity

    NASA Technical Reports Server (NTRS)

    Hurlbert, Kathryn M.; Witte, Larry C.

    2003-01-01

    A report presents a method of scaling, to partial-Earth gravity, of parameters that describe pressure drops and other characteristics of two-phase (liquid/ vapor) flows. The development of the method was prompted by the need for a means of designing two-phase flow systems to operate on the Moon and on Mars, using fluid-properties and flow data from terrestrial two-phase-flow experiments, thus eliminating the need for partial-gravity testing. The report presents an explicit procedure for designing an Earth-based test bed that can provide hydrodynamic similarity with two-phase fluids flowing in partial-gravity systems. The procedure does not require prior knowledge of the flow regime (i.e., the spatial orientation of the phases). The method also provides for determination of pressure drops in two-phase partial-gravity flows by use of a generalization of the classical Moody chart (previously applicable to single-phase flow only). The report presents experimental data from Mars- and Moon-activity experiments that appear to demonstrate the validity of this method.

  15. Measurement of Lipid Accumulation in Chlorella vulgaris via Flow Cytometry and Liquid-State ¹H NMR Spectroscopy for Development of an NMR-Traceable Flow Cytometry Protocol

    PubMed Central

    Bono Jr., Michael S.; Garcia, Ravi D.; Sri-Jayantha, Dylan V.; Ahner, Beth A.; Kirby, Brian J.

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r 2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols. PMID:26267664

  16. Measurement of lipid accumulation in Chlorella vulgaris via flow cytometry and liquid-state ¹H NMR spectroscopy for development of an NMR-traceable flow cytometry protocol.

    PubMed

    Bono, Michael S; Garcia, Ravi D; Sri-Jayantha, Dylan V; Ahner, Beth A; Kirby, Brian J

    2015-01-01

    In this study, we cultured Chlorella vulgaris cells with a range of lipid contents, induced via nitrogen starvation, and characterized them via flow cytometry, with BODIPY 505/515 as a fluorescent lipid label, and liquid-state 1H NMR spectroscopy. In doing so, we demonstrate the utility of calibrating flow cytometric measurements of algal lipid content using triacylglyceride (TAG, also known as triacylglycerol or triglyceride) content per cell as measured via quantitative 1H NMR. Ensemble-averaged fluorescence of BODIPY-labeled cells was highly correlated with average TAG content per cell measured by bulk NMR, with a linear regression yielding a linear fit with r2 = 0.9974. This correlation compares favorably to previous calibrations of flow cytometry protocols to lipid content measured via extraction, and calibration by NMR avoids the time and complexity that is generally required for lipid quantitation via extraction. Flow cytometry calibrated to a direct measurement of TAG content can be used to investigate the distribution of lipid contents for cells within a culture. Our flow cytometry measurements showed that Chlorella vulgaris cells subjected to nitrogen limitation exhibited higher mean lipid content but a wider distribution of lipid content that overlapped the relatively narrow distribution of lipid content for replete cells, suggesting that nitrogen limitation induces lipid accumulation in only a subset of cells. Calibration of flow cytometry protocols using direct in situ measurement of TAG content via NMR will facilitate rapid development of more precise flow cytometry protocols, enabling investigation of algal lipid accumulation for development of more productive algal biofuel feedstocks and cultivation protocols.

  17. Age, gender, and voided volume dependency of peak urinary flow rate and uroflowmetry nomogram in the Indian population

    PubMed Central

    Kumar, Vikash; Dhabalia, Jayesh V.; Nelivigi, Girish G.; Punia, Mahendra S.; Suryavanshi, Manav

    2009-01-01

    Objectives: The objective of this study was measurement of urine flow parameters by a non invasive urodynamic test. Variation of flow rates based on voided volume, age, and gender are described. Different nomograms are available for different populations and racial differences of urethral physiology are described. Currently, there has been no study from the Indian population on uroflow parameters. So the purpose of this study was to establish normal reference ranges of maximum and average flow rates, to see the influence of age, gender, and voided volume on flow rates, and to chart these values in the form of a nomogram. Methods: We evaluated 1,011 uroflowmetry tests in different age groups in a healthy population (healthy relatives of our patients) 16-50 year old males, >50 year old males, 5-15 year old children, and >15 year pre-menopausal and post-menopausal females. The uroflowmetry was done using the gravitimetric method. Flow chart parameters were analyzed and statistical calculations were used for drawing uroflow nomograms. Results: Qmax values in adult males were significantly higher than in the elderly and Qmax values in young females were significantly higher than in young males. Qmax values in males increased with age until 15 years old; followed by a slow decline until reaching 50 years old followed by a rapid decline after 50 years old even after correcting voided volume. Qmax values in females increased with age until they reached age 15 followed by decline in flow rate until a pre-menopausal age followed by no significant decline in post-menopausal females. Qmax values increased with voided volume until 700 cc followed by a plateau and decline. Conclusions: Qmax values more significantly correlated with age and voided volume than Qavg. Nomograms were drawn in centile form to provide normal reference ranges. Qmax values in our population were lower than described in literature. Patients with voided volume up to 50 ml could be evaluated with a nomogram. PMID:19955668

  18. A case study of printing industry plant layout for effective production

    NASA Astrophysics Data System (ADS)

    Viswajit, T.; Teja, T. Ravi; Deepthi, Y. P.

    2017-07-01

    This paper presents the overall picture of the processes happening in printing industry. This research is aimed to improve the plant layout of existing plant. The travel time was reduced by relocating machinery. Relocation is based on systematic layout planning (SLP). The complete process of raw material entering the industry to dispatching of finished product is shown in 3-D Flow diagram. The process happening in each floor explained in detail using Flow Process chart. Travel time is reduced by 25% after modifying existing plant layout.

  19. R2D2-A Fortran Program for Two-Dimensional Chemically Reacting, Hyperthermal, Internal Flows, Volume II.

    DTIC Science & Technology

    1980-01-01

    is identified in the flow chart simply as "Compute VECT’s ( predictor solution)" and "Compute V’s ( corrector solution)." A significant portion of the...TrintoTo Tm ANDera ionT SToION 28 ITIME :1 PRINCIPAL SUBROUTINES WALLPOINT (ITER,DT) ITER - iteration index for MacCormack Algorithm (ITER=1 for predictor ...WEILERSTEIN, R RAY, 6 MILLER F33615-7- C -3016UNLASSIFIED GASL-TR-254-VBL-2 AFFDL-TR-79-3162-VOL-2 NII III hImllllllllll EIEIIIIIIEIIEE EEIIIIIIIIIIII H

  20. Studies on transonic Double Circular Arc (DCA) profiles of axial flow compressor calculations of profile design

    NASA Astrophysics Data System (ADS)

    Rugun, Y.; Zhaoyan, Q.

    1986-05-01

    In this paper, the concepts and methods for design of high-Mach-number airfoils of axial flow compressor are described. The correlation-equations of main parameters such as geometries of airfoil and cascade, stream parameters and wake characteristic parameters of compressor are provided. For obtaining the total pressure loss coefficients of cascade and adopting the simplified calculating method, several curves and charts are provided by authors. The testing results and calculating values are compared, and both the results are in better agreement.

  1. SI-traceable standards for atmospheric monitoring of halogenated gases

    NASA Astrophysics Data System (ADS)

    Guillevic, Myriam; Wyss, Simon A.; Pascale, Céline; Vollmer, Martin K.; Niederhauser, Bernhard; Reimann, Stefan

    2017-04-01

    To support atmospheric monitoring of greenhouse gases and in particular halogenated gases, we have developed a method to produce reference gas mixtures at nmol/mol (ppb) to pmol/mol levels (ppt). This method is dynamic and SI-traceable. This work is conducted in the framework of the EMRP projects HIGHGAS and KEY-VOCs as well as METAS' AtmoChemECV project. The method has been already applied to HFC-125 (pentafluoroethane, widely used in air conditioners), HFC-1234yf (2,3,3,3-tetrafluoropropene, a car air conditioner fluid of growing importance) and SF6 (insulant in electric switch-gears). It is currently being extended to HCFC-132b and CFC-13. It is particularly suitable for gas species and/or concentration ranges that are not stable in cylinders and it can be applied to a large variety of molecules related to air pollution and climate change (e.g., NO2, volatile organic compounds such as BTEX, NH3, water vapour at ppm level, CFCs, HCFCs, HFCs). The expanded uncertainty is less than 3 % (95 % confidence interval or k=2). The generation process is composed of four successive steps. In the first step the matrix gas, nitrogen or synthetic air is purified. Then this matrix gas is spiked with the pure substance, using a permeation device which contains a few grams of the pure substance (e.g., HFC-125) in the liquid form and loses it linearly over time by permeation through a membrane. This mass loss is precisely calibrated in our lab in Bern, using a magnetic suspension balance. In a third step the desired concentration is reached by dilution of the high concentration mixture exiting the permeation chamber with a chosen flow of the matrix gas in one or two subsequent dilution steps. All flows are piloted by mass flow controllers. All parts in contact with the gas mixture - including the balance - are passivated using coated surfaces, to reduce adsorption/desorption processes as much as possible. In the last step the mixture can be i) directly used to calibrate an analyser, ii) sampled on sorbent tubes or iii) pressurized into Silconert2000-coated stainless steel cylinders by cryo-filling. We focus here on standards made for the gases HFC-125 and HFC-1234yf. We present here the method, the uncertainty budget as well as first results of intercomparisons to other references.

  2. The effect of prewhirl on the internal aerodynamics and performance of a mixed flow research centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Bryan, William B.; Fleeter, Sanford

    1987-01-01

    The internal three-dimensional steady and time-varying flow through the diffusing elements of a centrifugal impeller were investigated using a moderate scale, subsonic, mixed flow research compressor facility. The characteristics of the test facility which permit the measurement of internal flow conditions throughout the entire research compressor and radial diffuser for various operating conditions are described. Results are presented in the form of graphs and charts to cover a range of mass flow rates with inlet guide vane settings varying from minus 15 degrees to plus 45 degrees. The static pressure distributions in the compressor inlet section and on the impeller and exit diffuser vanes, as well as the overall pressure and temperature rise and mass flow rate, were measured and analyzed at each operating point to determine the overall performance as well as the detailed aerodynamics throughout the compressor.

  3. Traceable calibration of photovoltaic reference cells using natural sunlight

    NASA Astrophysics Data System (ADS)

    Müllejans, H.; Zaaiman, W.; Pavanello, D.; Dunlop, E. D.

    2018-02-01

    At the European Solar Test Installation (ESTI) photovoltaic (PV) reference cells are calibrated traceably to SI units via the World Radiometric Reference (WRR) using natural sunlight. The Direct Sunlight Method (DSM) is described in detail and the latest measurement results and an updated uncertainty budget are reported. These PV reference cells then provide a practical means for measuring the irradiance of natural or simulated sunlight during the calibration of other PV devices.

  4. Meeting the measurement uncertainty and traceability requirements of ISO/AEC standard 17025 in chemical analysis.

    PubMed

    King, B

    2001-11-01

    The new laboratory accreditation standard, ISO/IEC 17025, reflects current thinking on good measurement practice by requiring more explicit and more demanding attention to a number of activities. These include client interactions, method validation, traceability, and measurement uncertainty. Since the publication of the standard in 1999 there has been extensive debate about its interpretation. It is the author's view that if good quality practices are already in place and if the new requirements are introduced in a manner that is fit for purpose, the additional work required to comply with the new requirements can be expected to be modest. The paper argues that the rigour required in addressing the issues should be driven by customer requirements and the factors that need to be considered in this regard are discussed. The issues addressed include the benefits, interim arrangements, specifying the analytical requirement, establishing traceability, evaluating the uncertainty and reporting the information.

  5. Tracing Asian Seabass Individuals to Single Fish Farms Using Microsatellites

    PubMed Central

    Yue, Gen Hua; Xia, Jun Hong; Liu, Peng; Liu, Feng; Sun, Fei; Lin, Grace

    2012-01-01

    Traceability through physical labels is well established, but it is not highly reliable as physical labels can be easily changed or lost. Application of DNA markers to the traceability of food plays an increasingly important role for consumer protection and confidence building. In this study, we tested the efficiency of 16 polymorphic microsatellites and their combinations for tracing 368 fish to four populations where they originated. Using the maximum likelihood and Bayesian methods, three most efficient microsatellites were required to assign over 95% of fish to the correct populations. Selection of markers based on the assignment score estimated with the software WHICHLOCI was most effective in choosing markers for individual assignment, followed by the selection based on the allele number of individual markers. By combining rapid DNA extraction, and high-throughput genotyping of selected microsatellites, it is possible to conduct routine genetic traceability with high accuracy in Asian seabass. PMID:23285169

  6. Consumer acceptance of a quick response (QR) code for the food traceability system: Application of an extended technology acceptance model (TAM).

    PubMed

    Kim, Yeong Gug; Woo, Eunju

    2016-07-01

    The objectives of this study are to apply the TAM using the addition of perceived information to individuals' behavioral intention to use the QR code for the food traceability system; and to determine the moderating effects of food involvement on the relationship between perceived information and perceived usefulness. Results from a survey of 420 respondents are analyzed using structural equation modeling. The study findings reveal that the extended TAM has a satisfactory fit to the data and that the underlying dimensions have a significant effect on consumers' intention to use the QR code for the food traceability system. In addition, food involvement plays a significant moderating function in the relationship between perceived information and perceived usefulness. The implications of this study for future research are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. A Collection Scheme for Tracing Information of Pig Safety Production

    NASA Astrophysics Data System (ADS)

    Luo, Qingyao; Xiong, Benhai; Yang, Liang

    This study takes one main production pattern of smallhold pig farming in Tianjin as a study prototype, deeply analyzes characters of informations about tracing inputs including vaccines,feeds,veterinary drugs and supervision test in pig farming, proposesinputs metadata, criteria for integrating inputs event and interface norms for data transmision, developes and completes identification of 2D ear tags and traceability information collection system of pig safety production based on mobile PDA. The system has implemented functions including setting and invalidate of 2D ear tags, collection of tracing inputs and supervision in the mobile PDA and finally integration of tracing events (the epidemic event,feed event,drug event and supervision event) on the traceability data center (server). The PDA information collection system has been applied for demonstration in Tianjin, the collection is simple, convenient and feasible. It could meet with requirements of traceability information system of pig safety production

  8. A new simplex chemometric approach to identify olive oil blends with potentially high traceability.

    PubMed

    Semmar, N; Laroussi-Mezghani, S; Grati-Kamoun, N; Hammami, M; Artaud, J

    2016-10-01

    Olive oil blends (OOBs) are complex matrices combining different cultivars at variable proportions. Although qualitative determinations of OOBs have been subjected to several chemometric works, quantitative evaluations of their contents remain poorly developed because of traceability difficulties concerning co-occurring cultivars. Around this question, we recently published an original simplex approach helping to develop predictive models of the proportions of co-occurring cultivars from chemical profiles of resulting blends (Semmar & Artaud, 2015). Beyond predictive model construction and validation, this paper presents an extension based on prediction errors' analysis to statistically define the blends with the highest predictability among all the possible ones that can be made by mixing cultivars at different proportions. This provides an interesting way to identify a priori labeled commercial products with potentially high traceability taking into account the natural chemical variability of different constitutive cultivars. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Identification of a Genomic Signature Predicting for Recurrence in Early Stage Ovarian Cancer

    DTIC Science & Technology

    2014-10-01

    55 Fruit St Boston, MA 02114-2554 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical...Sections were then dehydrated in 100% EtOH and air-dried before macro- dissection using a sterile, RNase-free scalpel. Figure 2. Flow-chart of

  10. Basic Electricity/Electronics (Industrial Arts). Vocational Education Curriculum Guide. Bulletin 1724.

    ERIC Educational Resources Information Center

    Louisiana State Dept. of Education, Baton Rouge. Div. of Vocational Education.

    This curriculum guide is designed to assist industrial arts teachers, counselors, and administrators in improving instruction in the areas of electricity and basic electronics. Included in the first part of the guide are a course flow chart, a course description, a discussion of target grade levels and prerequisites, course goals and objectives,…

  11. Return to the red planet: The Mars Observer Mission

    NASA Technical Reports Server (NTRS)

    French, Bevan M.; Young, Carolynn (Editor)

    1993-01-01

    An overview of the Mars Observer Mission is discussed. Highlights include: (1) the spacecraft; (2) the instrumentation and science experiments; (3) the countries involved; (4) the flight teams; and (5) the planet Mars itself (a brief history). Photographs and flow charts are included, along with diagrams of instrumentation and a brief historical narrative of space observation and exploration.

  12. Improving The Prototyping Process In Department Of Defense Acquisition

    DTIC Science & Technology

    2014-06-01

    System Flow Chart ................................................. 39 Figure 13. TRL Definitions (from ASD [R&E] 2011... ASD (R&E) Assistant Secretary of Defense for Research and Engineering BCL Business Capability Life cycle CDD Capability Development Document CDR...TRL 6 cannot be attained until the technology has been demonstrated in a relevant operational environment ( ASD [R&E] 2011). A technology that has

  13. Operation Prime Program (Central Junior High School), Title I Evaluation, 1973-76.

    ERIC Educational Resources Information Center

    Granite School District, Salt Lake City, UT.

    This document consists of reports (for the 1973-1974, 1974-1975, and 1975-1976 school years) of an individualized reading and math program designed for secondary school students functioning below their grade level. The program involves a management system using flow charts, independent study, student motivation provided by free time in a…

  14. Pennsylvania Environmental Education Master Plan. New Direction Across the State... ...For the Total Community.

    ERIC Educational Resources Information Center

    Pennsylvania State Dept. of Environmental Resources, Harrisburg.

    This document is Pennsylvania's master plan for environmental education (EE). It includes: (1) a list of planning principles and guidelines to enhance implementation of the master plan; (2) a flow chart illustrating feasibility, planning, action, and impact phases for the years 1983-85; (3) a summary of major recommendations; (4) a chart…

  15. Section I: Basic Electricity. Syllabus in Trade Electricity-Electronics.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Occupational and Career Curriculum Development.

    This section describes the first of a three part curriculum in trade electricity-electronics (each part is described in a separate volume). It presents a unit of 6 to 10 weeks duration which develops only those competencies necessary to all electricity or electronics employment. A flow chart indicates how an individual student's program can be…

  16. Compliance Timeline, Compliance Options, and Required Notifications for Surface Coating of Wood Building Products National Emission Standards for Hazardous Air Pollutants (NESHAP)

    EPA Pesticide Factsheets

    This January 2005 document contains a diagram of dates and events for compliance with the NESHAP for surface coating of wood building products. Also on this page is a January 2005 document with flow charts to demonstrate compliance options for the NESHAP

  17. Planning for Schools of Choice: Achieving Equity and Excellence. Book II--Planning Guide.

    ERIC Educational Resources Information Center

    Clinchy, Evans; Kolb, Frances Arick, Ed.

    Designed to aid school personnel considering school choice as a possible desegregation method, this booklet explains the principles of controlled choice, presents an overall plan and flow chart, and reviews the types of organizations that might be developed. Controlled choice is a desegregation method that is voluntary, empowers parents and school…

  18. Analysis of a Digital Technique for Frequency Transposition of Speech.

    DTIC Science & Technology

    1985-09-01

    scaled excitation function drives the vocal tract model. In a phone interview with James Kaiser of Bell Laboratories, he mentioned that current thinking...is processed using the Fast Fourier Transform (FFT) and then low pass filtered if desired. mAbe (Pb) FFT LPF- nih ~a s5ee.. S. 4Nrf#Nr Flow Chart for

  19. Mathematics for the Technical Student: The Use of the Computer in the Systems Approach to Instruction.

    ERIC Educational Resources Information Center

    Capps, Joan P.

    An instructional method using flow-chart symbols to make mathematical abstractions more concrete was implemented for a year in a technical mathematics course. Students received instruction in computer applications and programming in the BASIC language in order to increase motivation and firm the mathematical skills and problem-solving approaches…

  20. Automated Program Recognition by Graph Parsing

    DTIC Science & Technology

    1992-07-01

    structures (cliches) in a program can help an experienced programmer understand the program. Based on the known relationships between the clichis, a...Graph Parsing Linda Mary Wills Abstract The recognition of standard computational structures (cliches) in a program can help an experienced programmer...3.4.1 Structure -Sharing ....... ............................ 76 3.4.2 Aggregation ....................................... 80 2 3.5 Chart Parsing Flow

  1. Statistical Measures, Hypotheses, and Tests in Applied Research

    ERIC Educational Resources Information Center

    Saville, David J.; Rowarth, Jacqueline S.

    2008-01-01

    This article reviews and discusses the use of statistical concepts in a natural resources and life sciences journal on the basis of a census of the articles published in a recent issue of the "Agronomy Journal" and presents a flow chart and a graph that display the inter-relationships between the most commonly used statistical terms. It also…

  2. Identifying, Tracking, and Prioritizing Parts Unavailability

    DTIC Science & Technology

    2013-03-01

    of RFM with MRP Equivalents in Parentheses ................ 13 Figure 2. Flow Chart of Repair Process...by the Air Force is the Reparability Forecast Model (RFM). The RFM operates similar to a Material Requirements Planning ( MRP ) system, where it...Outputs of RFM with MRP Equivalents in Parentheses (Gaudette et al, 2002: 7) The Reparability Forecast Model does not determine stock levels or

  3. Calculus: A Computer Oriented Presentation, Part 1 [and] Part 2.

    ERIC Educational Resources Information Center

    Stenberg, Warren; Walker, Robert J.

    Parts one and two of a one-year computer-oriented calculus course (without analytic geometry) are presented. The ideas of calculus are introduced and motivated through computer (i.e., algorithmic) concepts. An introduction to computing via algorithms and a simple flow chart language allows the book to be self-contained, except that material on…

  4. Orbital transfer vehicle studies overview

    NASA Technical Reports Server (NTRS)

    Perkinson, Don

    1987-01-01

    An overview is given in viewgraph form of orbital transfer vehicle concept definition and systems analysis studies. Project development flow charts are shown for key milestones from 1985 until 1997. Diagrams of vehicles are given. Information is presented in outline form on technology requirements, cooling of propellant tanks, cryogenic fluid management, quick connect/disconnect fluid interfaces and propellant mass transfer.

  5. JPRS Report, Science & Technology, China, 16th International Congress of the International Society for Photogrammetry and Remote Sensing -- Vol. 1

    DTIC Science & Technology

    1989-01-26

    introduction, review and prospects." AUTOCARTO 8 pp 510-519. [VOY 10] VOYER: " Moteurs de systemes experts." Eyrolles editions 61, Bd. St.-Germain 75005...each knowlege Output of Extrated Results Oceanic Conditions Extraction Meta -Rule Base Figure 3. General Flow Chart of the System 207

  6. Skylab S-191 spectrometer single spectral scan analysis program. [user manual

    NASA Technical Reports Server (NTRS)

    Downes, E. L.

    1974-01-01

    Documentation and user information for the S-191 single spectral scan analysis program are reported. A breakdown of the computational algorithms is supplied, followed by the program listing and examples of sample output. A copy of the flow chart which describes the driver routine in the body of the main program segment is included.

  7. Mapping individual logical processes in information searching

    NASA Technical Reports Server (NTRS)

    Smetana, F. O.

    1974-01-01

    An interactive dialog with a computerized information collection was recorded and plotted in the form of a flow chart. The process permits one to identify the logical processes employed in considerable detail and is therefore suggested as a tool for measuring individual thought processes in a variety of situations. A sample of an actual test case is given.

  8. Power/Energy (Industrial Arts). Vocational Education Curriculum Guide. Bulletin 1723.

    ERIC Educational Resources Information Center

    Louisiana State Dept. of Education, Baton Rouge. Div. of Vocational Education.

    This curriculum guide is designed to assist industrial arts practitioners in improving instruction in the areas of energy and power technology. Included in the first part of the guide are a course flow chart, a course description, a discussion of target grade levels and prerequisites, course goals and objectives, an introduction, and a course…

  9. College Achievement Through Self-Help. A Planning and Guidance Manual For Minority Students.

    ERIC Educational Resources Information Center

    Nieves, Luis

    In this manual for minority students in higher education, advice is provided on the following topics: (1) methods of self personality assessment, including lists, questions, and flow charts; (2) suggestions for budgeting study time in an individual schedule; (3) relaxation techniques to combat anxiety; (4) methods of self-management in cases of…

  10. New York State Educational Information System (NYSEIS) Systems Design. Volume I, Phase II. Final Report.

    ERIC Educational Resources Information Center

    Price Waterhouse and Co., New York, NY.

    This volume on Phase II of the New York State Educational Information System (NYSEIS) describes the Gross Systems Analysis and Design, which includes the general flow diagram and processing chart for each of the student, personnel, and financial subsystems. Volume II, Functional Specifications, includes input/output requirements and file…

  11. A Classroom Note on: Modeling Functions with the TI-83/84 Calculator

    ERIC Educational Resources Information Center

    Lubowsky, Jack

    2011-01-01

    In Pre-Calculus courses, students are taught the composition and combination of functions to model physical applications. However, when combining two or more functions into a single more complicated one, students may lose sight of the physical picture which they are attempting to model. A block diagram, or flow chart, in which each block…

  12. Teaching Inferential Statistics to Social Work Students: A Decision-Making Flow Chart

    ERIC Educational Resources Information Center

    Calderwood, Kimberly A.

    2012-01-01

    Given that social work research courses are typically built on modernist principles of teaching and content, it is not surprising that the majority of social work students dread these courses. Few attempts have been made to better align the modernist content of quantitative research with the postmodern philosophy and values inherent in current…

  13. Aerodynamic Design of Axial-flow Compressors. Volume III

    NASA Technical Reports Server (NTRS)

    Johnson, Irving A; Bullock, Robert O; Graham, Robert W; Costilow, Eleanor L; Huppert, Merle C; Benser, William A; Herzig, Howard Z; Hansen, Arthur G; Jackson, Robert J; Yohner, Peggy L; hide

    1956-01-01

    Chapters XI to XIII concern the unsteady compressor operation arising when compressor blade elements stall. The fields of compressor stall and surge are reviewed in Chapters XI and XII, respectively. The part-speed operating problem in high-pressure-ratio multistage axial-flow compressors is analyzed in Chapter XIII. Chapter XIV summarizes design methods and theories that extend beyond the simplified two-dimensional approach used previously in the report. Chapter XV extends this three-dimensional treatment by summarizing the literature on secondary flows and boundary layer effects. Charts for determining the effects of errors in design parameters and experimental measurements on compressor performance are given in Chapters XVI. Chapter XVII reviews existing literature on compressor and turbine matching techniques.

  14. Development of Traceable Phantoms for Improved Image Quantification in Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zimmerman, Brian

    2014-03-01

    Clinical trials for new drugs increasingly rely on imaging data to monitor patient response to the therapy being studied. In the case of radiopharmaceutical applications, imaging data are also used to estimate organ and tumor doses in order to arrive at the optimal dosage for safe and effective treatment. Positron Emission Tomography (PET) is one of the most commonly used imaging modalities for these types of applications. In large, multicenter trials it is crucial to minimize as much as possible the variability that arises due to use of different types of scanners and other instrumentation so that the biological response can be more readily evaluated. This can be achieved by ensuring that all the instruments are calibrated to a common standard and that their performance is continuously monitored throughout the trial. Maintaining links to a single standard also enables the comparability of data acquired on a heterogeneous collection of instruments in different clinical settings. As the standards laboratory for the United States, the National Institute of Standards and Technology (NIST) has been developing a suite of phantoms having traceable activity content to enable scanner calibration and performance testing. The configurations range from small solid cylindrical sources having volumes from 1 mL to 23 mL to large cylinders having a total volume of 9 L. The phantoms are constructed with 68Ge as a long-lived substitute for the more clinically useful radionuclide 18F. The contained activity values are traceable to the national standard for 68Ge and are also linked to the standard for 18F through a careful series of comparisons. The techniques that have been developed are being applied to a variety of new phantom configurations using different radionuclides. Image-based additive manufacturing techniques are also being investigated to create fillable phantoms having irregular shapes which can better mimic actual organs and tumors while still maintaining traceability back to primary standards for radioactivity. This talk will describe the methods used to construct, calibrate, and characterize the phantoms, focusing on the preservation of the traceability link to the primary standards of the radionuclides used. The on-going development of specialized traceable phantoms for specific organ dosimetry applications and imaging physics studies will also be discussed.

  15. A Coordinated Research Project on the Implementation of Nuclear Techniques to Improve Food Traceability

    NASA Astrophysics Data System (ADS)

    Frew, Russell; Cannavan, Andrew; Zandric, Zora; Maestroni, Britt; Abrahim, Aiman

    2013-04-01

    Traceability systems play a key role in assuring a safe and reliable food supply. Analytical techniques harnessing the spatial patterns in distribution of stable isotope and trace element ratios can be used for the determination of the provenance of food. Such techniques offer the potential to enhance global trade by providing an independent means of verifying "paper" traceability systems and can also help to prove authenticity, to combat fraudulent practices, and to control adulteration, which are important issues for economic, religious or cultural reasons. To address some of the challenges that developing countries face in attempting to implement effective food traceability systems, the IAEA, through its Joint FAO/IAEA Division on Nuclear Techniques in Food and Agriculture, has initiated a 5-year coordinated research project involving institutes in 15 developing and developed countries (Austria, Botswana, Chile, China, France, India, Lebanon, Morocco, Portugal, Singapore, Sweden, Thailand, Uganda, UK, USA). The objective is to help in member state laboratories to establish robust analytical techniques and databases, validated to international standards, to determine the provenance of food. Nuclear techniques such as stable isotope and multi-element analysis, along with complementary methods, will be applied for the verification of food traceability systems and claims related to food origin, production, and authenticity. This integrated and multidisciplinary approach to strengthening capacity in food traceability will contribute to the effective implementation of holistic systems for food safety and control. The project focuses mainly on the development of techniques to confirm product authenticity, with several research partners also considering food safety issues. Research topics encompass determination of the geographical origin of a variety of commodities, including seed oils, rice, wine, olive oil, wheat, orange juice, fish, groundnuts, tea, pork, honey and coffee, the adulteration of milk with soy protein, chemical contamination of food products, and inhomogeneity in isotopic ratios in poultry and eggs as a means to determine production history. Analytical techniques include stable isotope ratio measurements (2H/1H, 13C/12C, 15N/14N, 18O/16O, 34S/32S, 87Sr/86Sr, 208Pb/207Pb/206Pb), elemental analysis, DNA fingerprinting, fatty acid and other biomolecule profiling, chromatography-mass spectrometry and near infra-red spectroscopy.

  16. A spectral chart method for estimating the mean turbulent kinetic energy dissipation rate

    NASA Astrophysics Data System (ADS)

    Djenidi, L.; Antonia, R. A.

    2012-10-01

    We present an empirical but simple and practical spectral chart method for determining the mean turbulent kinetic energy dissipation rate < \\varepsilon rangle in a variety of turbulent flows. The method relies on the validity of the first similarity hypothesis of Kolmogorov (C R (Doklady) Acad Sci R R SS, NS 30:301-305, 1941) (or K41) which implies that spectra of velocity fluctuations scale on the kinematic viscosity ν and < \\varepsilon rangle at large Reynolds numbers. However, the evidence, based on the DNS spectra, points to this scaling being also valid at small Reynolds numbers, provided effects due to inhomogeneities in the flow are negligible. The methods avoid the difficulty associated with estimating time or spatial derivatives of the velocity fluctuations. It also avoids using the second hypothesis of K41, which implies the existence of a -5/3 inertial subrange only when the Taylor microscale Reynods number R λ is sufficiently large. The method is in fact applied to the lower wavenumber end of the dissipative range thus avoiding most of the problems due to inadequate spatial resolution of the velocity sensors and noise associated with the higher wavenumber end of this range.The use of spectral data (30 ≤ R λ ≤ 400) in both passive and active grid turbulence, a turbulent mixing layer and the turbulent wake of a circular cylinder indicates that the method is robust and should lead to reliable estimates of < \\varepsilon rangle in flows or flow regions where the first similarity hypothesis should hold; this would exclude, for example, the region near a wall.

  17. Comprehensive protocol of traceability during IVF: the result of a multicentre failure mode and effect analysis.

    PubMed

    Rienzi, L; Bariani, F; Dalla Zorza, M; Albani, E; Benini, F; Chamayou, S; Minasi, M G; Parmegiani, L; Restelli, L; Vizziello, G; Costa, A Nanni

    2017-08-01

    Can traceability of gametes and embryos be ensured during IVF? The use of a simple and comprehensive traceability system that includes the most susceptible phases during the IVF process minimizes the risk of mismatches. Mismatches in IVF are very rare but unfortunately possible with dramatic consequences for both patients and health care professionals. Traceability is thus a fundamental aspect of the treatment. A clear process of patient and cell identification involving witnessing protocols has to be in place in every unit. To identify potential failures in the traceability process and to develop strategies to mitigate the risk of mismatches, previously failure mode and effects analysis (FMEA) has been used effectively. The FMEA approach is however a subjective analysis, strictly related to specific protocols and thus the results are not always widely applicable. To reduce subjectivity and to obtain a widespread comprehensive protocol of traceability, a multicentre centrally coordinated FMEA was performed. Seven representative Italian centres (three public and four private) were selected. The study had a duration of 21 months (from April 2015 to December 2016) and was centrally coordinated by a team of experts: a risk analysis specialist, an expert embryologist and a specialist in human factor. Principal investigators of each centre were first instructed about proactive risk assessment and FMEA methodology. A multidisciplinary team to perform the FMEA analysis was then formed in each centre. After mapping the traceability process, each team identified the possible causes of mistakes in their protocol. A risk priority number (RPN) for each identified potential failure mode was calculated. The results of the FMEA analyses were centrally investigated and consistent corrective measures suggested. The teams performed new FMEA analyses after the recommended implementations. In each centre, this study involved: the laboratory director, the Quality Control & Quality Assurance responsible, Embryologist(s), Gynaecologist(s), Nurse(s) and Administration. The FMEA analyses were performed according to the Joint Commission International. The FMEA teams identified seven main process phases: oocyte collection, sperm collection, gamete processing, insemination, embryo culture, embryo transfer and gamete/embryo cryopreservation. A mean of 19.3 (SD ± 5.8) associated process steps and 41.9 (SD ± 12.4) possible failure modes were recognized per centre. A RPN ≥15 was calculated in a mean of 6.4 steps (range 2-12, SD ± 3.60). A total of 293 failure modes were centrally analysed 45 of which were considered at medium/high risk. After consistent corrective measures implementation and re-evaluation, a significant reduction in the RPNs in all centres (RPN <15 for all steps) was observed. A simple and comprehensive traceability system was designed as the result of the seven FMEA analyses. The validity of FMEA is in general questionable due to the subjectivity of the judgments. The design of this study has however minimized this risk by introducing external experts for the analysis of the FMEA results. Specific situations such as sperm/oocyte donation, import/export and pre-implantation genetic testing were not taken into consideration. Finally, this study is only limited to the analysis of failure modes that may lead to mismatches, other possible procedural mistakes are not accounted for. Every single IVF centre should have a clear and reliable protocol for identification of patients and traceability of cells during manipulation. The results of this study can support IVF groups in better recognizing critical steps in their protocols, understanding identification and witnessing process, and in turn enhancing safety by introducing validated corrective measures. This study was designed by the Italian Society of Embryology Reproduction and Research (SIERR) and funded by the Italian National Transplant Centre (CNT) of the Italian National Institute of Health (ISS). The authors have no conflicts of interest. N/A. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  18. Review: Authentication and traceability of foods from animal origin by polymerase chain reaction-based capillary electrophoresis.

    PubMed

    Rodríguez-Ramírez, Roberto; González-Córdova, Aarón F; Vallejo-Cordoba, Belinda

    2011-01-31

    This work presents an overview of the applicability of PCR-based capillary electrophoresis (CE) in food authentication and traceability of foods from animal origin. Analytical approaches for authenticating and tracing meat and meat products and fish and seafood products are discussed. Particular emphasis will be given to the usefulness of genotyping in food tracing by using CE-based genetic analyzers. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Waste collection multi objective model with real time traceability data.

    PubMed

    Faccio, Maurizio; Persona, Alessandro; Zanin, Giorgia

    2011-12-01

    Waste collection is a highly visible municipal service that involves large expenditures and difficult operational problems, plus it is expensive to operate in terms of investment costs (i.e. vehicles fleet), operational costs (i.e. fuel, maintenances) and environmental costs (i.e. emissions, noise and traffic congestions). Modern traceability devices, like volumetric sensors, identification RFID (Radio Frequency Identification) systems, GPRS (General Packet Radio Service) and GPS (Global Positioning System) technology, permit to obtain data in real time, which is fundamental to implement an efficient and innovative waste collection routing model. The basic idea is that knowing the real time data of each vehicle and the real time replenishment level at each bin makes it possible to decide, in function of the waste generation pattern, what bin should be emptied and what should not, optimizing different aspects like the total covered distance, the necessary number of vehicles and the environmental impact. This paper describes a framework about the traceability technology available in the optimization of solid waste collection, and introduces an innovative vehicle routing model integrated with the real time traceability data, starting the application in an Italian city of about 100,000 inhabitants. The model is tested and validated using simulation and an economical feasibility study is reported at the end of the paper. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.

    PubMed

    Jones, Graham R D; Jackson, Craig

    2016-01-30

    The Joint Committee for Traceability in Laboratory Medicine (JCTLM) was formed to bring together the sciences of metrology, laboratory medicine and laboratory quality management. The aim of this collaboration is to support worldwide comparability and equivalence of measurement results in clinical laboratories for the purpose of improving healthcare. The JCTLM has its origins in the activities of international metrology treaty organizations, professional societies and federations devoted to improving measurement quality in physical, chemical and medical sciences. The three founding organizations, the International Committee for Weights and Measures (CIPM), the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and the International Laboratory Accreditation Cooperation (ILAC) are the leaders of this activity. The main service of the JCTLM is a web-based database with a list of reference materials, reference methods and reference measurement services meeting appropriate international standards. This database allows manufacturers to select references for assay traceability and provides support for suppliers of these services. As of mid 2015 the database lists 295 reference materials for 162 analytes, 170 reference measurement procedures for 79 analytes and 130 reference measurement services for 39 analytes. There remains a need for the development and implementation of metrological traceability in many areas of laboratory medicine and the JCTLM will continue to promote these activities into the future. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  2. FlowSOM: Using self-organizing maps for visualization and interpretation of cytometry data.

    PubMed

    Van Gassen, Sofie; Callebaut, Britt; Van Helden, Mary J; Lambrecht, Bart N; Demeester, Piet; Dhaene, Tom; Saeys, Yvan

    2015-07-01

    The number of markers measured in both flow and mass cytometry keeps increasing steadily. Although this provides a wealth of information, it becomes infeasible to analyze these datasets manually. When using 2D scatter plots, the number of possible plots increases exponentially with the number of markers and therefore, relevant information that is present in the data might be missed. In this article, we introduce a new visualization technique, called FlowSOM, which analyzes Flow or mass cytometry data using a Self-Organizing Map. Using a two-level clustering and star charts, our algorithm helps to obtain a clear overview of how all markers are behaving on all cells, and to detect subsets that might be missed otherwise. R code is available at https://github.com/SofieVG/FlowSOM and will be made available at Bioconductor. © 2015 International Society for Advancement of Cytometry.

  3. Analysis of Substrates of Protein Kinase C Isoforms in Human Breast Cells By The Traceable Kinase Method

    PubMed Central

    Chen, Xiangyu; Zhao, Xin; Abeyweera, Thushara P.; Rotenberg, Susan A.

    2012-01-01

    A previous report (Biochemistry 46: 2364–2370, 2007) described the application of The Traceable Kinase Method to identify substrates of PKCα in non-transformed human breast MCF-10A cells. Here, a non-radioactive variation of this method compared the phospho-protein profiles of three traceable PKC isoforms (α, δ and ζ) for the purpose of identifying novel, isoform-selective substrates. Each FLAG-tagged traceable kinase was expressed and co-immunoprecipitated along with high affinity substrates. The isolated kinase and its associated substrates were subjected to an in vitro phosphorylation reaction with traceable kinase-specific N6-phenyl-ATP, and the resulting phospho-proteins were analyzed by Western blot with an antibody that recognizes the phosphorylated PKC consensus site. Phospho-protein profiles generated by PKC-α and -δ were similar and differed markedly from that of PKC-ζ. Mass spectrometry of selected bands revealed known PKC substrates and several potential substrates that included the small GTPase-associated effector protein Cdc42 effector protein-4 (CEP4). Of those potential substrates tested, only CEP4 was phosphorylated by pure PKC-α, –δ, and −ζ isoforms in vitro, and by endogenous PKC isoforms in MCF-10A cells treated with DAG-lactone, a membrane permeable PKC activator. Under these conditions, the stoichiometry of CEP4 phosphorylation was 3.2 ± 0.5 (mol phospho-CEP4/mol CEP4). Following knock-down with isoform-specific shRNA-encoding plasmids, phosphorylation of CEP4 was substantially decreased in response to silencing of each of the three isoforms (PKC–α, –δ, or –ζ), whereas testing of kinase-dead mutants supported a role for only PKC-α and –δ in CEP4 phosphorylation. These findings identify CEP4 as a novel intracellular PKC substrate that is phosphorylated by multiple PKC isoforms. PMID:22897107

  4. An analytical approach to thermal modeling of Bridgman type crystal growth: One dimensional analysis. Computer program users manual

    NASA Technical Reports Server (NTRS)

    Cothran, E. K.

    1982-01-01

    The computer program written in support of one dimensional analytical approach to thermal modeling of Bridgman type crystal growth is presented. The program listing and flow charts are included, along with the complete thermal model. Sample problems include detailed comments on input and output to aid the first time user.

  5. A Study of Acoustic Forcing on Gas Centered Swirl Coaxial Reacting Flows (Conference Paper with Briefing Charts)

    DTIC Science & Technology

    2017-01-09

    intensifier with a Semrock filter (FF01-425/26). The reflective surface of this dichroic mirror rejected the blue light portion from the broadband...chemiluminescence was also imaged using a HiCATT intensifier with a Semrock filter (FF01-320/40). The shadowgraph camera was set to a gate of 7 µs

  6. An Integrated Approach to the Use of Complementary Visual Learning Tools in an Undergraduate Microbiology Class

    ERIC Educational Resources Information Center

    McCabe, Bernadette

    2011-01-01

    The ability to appreciate the inter-connectedness of complex biological relationships can be difficult for many students. Graphical knowledge in the form of concept maps and flow charts are learning tools which can assist students to recognise the inter-connectivity. This report focuses on a trial which incorporates these two related visual…

  7. Digital adaptive controllers for VTOL vehicles. Volume 2: Software documentation

    NASA Technical Reports Server (NTRS)

    Hartmann, G. L.; Stein, G.; Pratt, S. G.

    1979-01-01

    The VTOL approach and landing test (VALT) adaptive software is documented. Two self-adaptive algorithms, one based on an implicit model reference design and the other on an explicit parameter estimation technique were evaluated. The organization of the software, user options, and a nominal set of input data are presented along with a flow chart and program listing of each algorithm.

  8. Study of EPR/ESR Dosimetry in Fingernails as a Method for Assessing Dose of Victims of Radiological Accidents/Incidents

    DTIC Science & Technology

    2008-06-17

    dosimeters . .............................................................................................. 117 Figure 4-2. Flow chart illustrating...alanine, various sugars, quartz in rocks and sulfates, as EPR dosimeters [15]. Alternatively, radiation-induced EPR signals have been detected using...the medical response to radiological accidents, as a method for estimating radiation dose without the use of physical dosimeters and using exposed

  9. Sizing-tube-fin space radiators

    NASA Technical Reports Server (NTRS)

    Peoples, J. A.

    1978-01-01

    Temperature and size considerations of the tube fin space radiator were characterized by charts and equations. An approach of accurately assessing rejection capability commensurate with a phase A/B level output is reviewed. A computer program, based on Mackey's equations, is also presented which sizes the rejection area for a given thermal load. The program also handles the flow and thermal considerations of the film coefficient.

  10. Calculations for interpretation of solar vector magnetograph data. [sunspots - spectrum analysis/data correlation

    NASA Technical Reports Server (NTRS)

    Dunn, A. R.

    1975-01-01

    Computer techniques for data analysis of sunspot observations are presented. Photographic spectra were converted to digital form and analyzed. Methods of determining magnetic field strengths, i.e., the Zeeman effect, are discussed. Errors originating with telescope equipment and the magnetograph are treated. Flow charts of test programs and procedures of the data analysis are shown.

  11. The GLAS Science Algorithm Software (GSAS) Detailed Design Document Version 6. Volume 16

    NASA Technical Reports Server (NTRS)

    Lee, Jeffrey E.

    2013-01-01

    The Geoscience Laser Altimeter System (GLAS) is the primary instrument for the ICESat (Ice, Cloud and Land Elevation Satellite) laser altimetry mission. ICESat was the benchmark Earth Observing System (EOS) mission for measuring ice sheet mass balance, cloud and aerosol heights, as well as land topography and vegetation characteristics. From 2003 to 2009, the ICESat mission provided multi-year elevation data needed to determine ice sheet mass balance as well as cloud property information, especially for stratospheric clouds common over polar areas. It also provided topography and vegetation data around the globe, in addition to the polar-specific coverage over the Greenland and Antarctic ice sheets.This document describes the detailed design of GLAS Science Algorithm Software (GSAS). The GSAS is used to create the ICESat GLAS standard data products. The National Snow and Ice Data Center (NSDIC) distribute these products. The document contains descriptions, flow charts, data flow diagrams, and structure charts for each major component of the GSAS. The purpose of this document is to present the detailed design of the GSAS. It is intended as a reference source to assist the maintenance programmer in making changes that fix or enhance the documented software.

  12. Endodontic-related inferior alveolar nerve injuries: A review and a therapeutic flow chart.

    PubMed

    Castro, R; Guivarc'h, M; Foletti, J M; Catherine, J H; Chossegros, C; Guyot, L

    2018-05-03

    Inferior alveolar nerve (IAN) lesions related to endodontic treatments can be explained by the anatomical proximity between the apices of the mandibular posterior teeth and the mandibular canal. The aim of this article is to review the management of inferior alveolar nerve lesions due to endodontic treatments and to establish a therapeutic flow chart. A review of publications reporting IAN damage related to endodontic treatment over the past 20 years has been conducted, using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist; it combines an electronic search of the Pubmed ® and Google Scholar ® databasis. Forty-two full-text articles corresponding to 115 clinical cases have been selected. Two personal clinical cases were additionally reported. IAN lesions due to endodontic treatments require urgent management. Early surgical removal of the excess of endodontic material, in contact with the nerve allows the best recovery prognosis (72h). Beyond this delay, irreversible nervous lesions prevail and a medical symptomatic treatment, most of the time with pregabalin, must be/can be carried out. A delayed surgical procedure shows some good benefits for patients. However, the healing prognosis remains poorly predictable. Copyright © 2018. Published by Elsevier Masson SAS.

  13. A primary standard for the calibration of sniffer test leak devices

    NASA Astrophysics Data System (ADS)

    Jousten, Karl; Becker, Ute

    2009-10-01

    Test leaks with a gas flow to atmospheric pressure are often called sniffer test leaks. They are used to calibrate leak detectors for sniffing applications. Sniffer test leaks need calibration against a standard. A primary standard for the calibration of sniffer test leaks with relatively low measurement uncertainties is described. It is assured that the measurement result is traceable to the relevant SI units and that there is a well-known and complete measurement uncertainty budget. The measurement range of the system is from 4 × 10-11 mol s-1 (corresponding to 10-4 Pa l s-1 at 23 °C) to 4 × 10-9 mol s-1 (10-2 Pa l s-1 at 23 °C), which is the most often needed range in industry of around 1 g loss per year of the cooling agent R134a. The temperature where the calibration can be carried out may vary from 18 °C to 30 °C. The flow rate of any test gas not condensing in this temperature range can be measured.

  14. Quality data collection and management technology of aerospace complex product assembly process

    NASA Astrophysics Data System (ADS)

    Weng, Gang; Liu, Jianhua; He, Yongxi; Zhuang, Cunbo

    2017-04-01

    Aiming at solving problems of difficult management and poor traceability for discrete assembly process quality data, a data collection and management method is proposed which take the assembly process and BOM as the core. Data collection method base on workflow technology, data model base on BOM and quality traceability of assembly process is included in the method. Finally, assembly process quality data management system is developed and effective control and management of quality information for complex product assembly process is realized.

  15. Study and Development of Mobile Tracingterminal Based on Gprs for Agriculturalproducts Quality Tracking

    NASA Astrophysics Data System (ADS)

    Liu, Shihong; Meng, Hong; Zheng, Huoguo; Wu, Jiangshou

    Traceability system has become an important means for food safety management. Global food industry and many countries have paid increasing attention to the construction of food traceability system, but rarely referred to tracing terminal. According to the technical requirements of cereal and oil products quality safety tracing process, we design and develop a mobile tracing terminal based on GPRS for agricultural products quality tracking to facilitate quality supervisors and consumers to track and trace the quality of related agricultural products anytime ,anywhere.

  16. Study of mechanism improving target course traceability in G-Vectoring Control

    NASA Astrophysics Data System (ADS)

    Yamakado, Makoto; Abe, Masato; Kano, Yoshio; Umetsu, Daisuke; Yoshioka, Thoru

    2018-05-01

    Production-type G-Vectoring Control vehicles are now being put on the market. Customers and reviewers have praised the handling quality and course traceability of these vehicles. This paper clarifies the mechanism behind this improvement in handling quality using a simple bicycle model and driver model analysis. It focuses on the residual yaw angular acceleration when the steering speed is zero and shows that GVC reduces its value. This result provides evidence for improved handling quality in GVC vehicles.

  17. A 4-cylinder Stirling engine computer program with dynamic energy equations

    NASA Technical Reports Server (NTRS)

    Daniele, C. J.; Lorenzo, C. F.

    1983-01-01

    A computer program for simulating the steady state and transient performance of a four cylinder Stirling engine is presented. The thermodynamic model includes both continuity and energy equations and linear momentum terms (flow resistance). Each working space between the pistons is broken into seven control volumes. Drive dynamics and vehicle load effects are included. The model contains 70 state variables. Also included in the model are piston rod seal leakage effects. The computer program includes a model of a hydrogen supply system, from which hydrogen may be added to the system to accelerate the engine. Flow charts are provided.

  18. Theoretical and Measured Attenuation of Mufflers at Room Temperature Without Flow, with Comments on Engine-exhaust Muffler Design

    NASA Technical Reports Server (NTRS)

    Davis, Don D , Jr; Stevens, George L , Jr; Moore, Dewey; Stokes, George M

    1953-01-01

    Equations are presented for the attenuation characteristics of several types of mufflers. Experimental curves of attenuation plotted against frequency are presented for 77 different mufflers and the results are compared with theory. The experiments were made at room temperature without flow and the sound source was a loud-speaker. A method is given for including the tail pipe in the calculations. The application of the theory to the design of engine-exhaust mufflers is discussed, and charts have been included for the assistance of the designer.

  19. A range of newly developed mobile generators to dynamically produce SI-traceable reference gas mixtures for reactive compounds at atmospheric concentrations

    NASA Astrophysics Data System (ADS)

    Leuenberger, Daiana; Pascale, Céline; Guillevic, Myriam; Ackermann, Andreas; Niederhauser, Bernhard

    2017-04-01

    Three new mobile facilities have been developed at METAS to dynamically generate SI-traceable reference gas mixtures for a variety of reactive compounds at atmospheric amount of substance fractions and at very low levels of uncertainty (Ux < 3%). We present three new portable "Reactive Gas Standard ReGaS" reference gas generators for the realisation of the following substances: ReGaS1: Ammonia and nitrogen dioxide in the nmol/mol (ppb) range ReGaS2: Volatile organic compounds (VOCs), e.g. limonene, alpha-pinene, MVK, MEK in the nmol/mol (ppb) range ReGaS-3: Fluorinated gases (F-gases, i.e. containing fluorine atoms) in the pmol/mol (ppt) range These three mobile generators have been designed and manufactured at METAS in the framework of the three EMRP projects MetNH3, KEY-VOCs and HIGHGAS. The method is based on permeation and subsequent dynamic dilution: A permeation tube containing the pure substance (e.g. NH3) is stored in the permeation chamber at constant temperature, pressure and matrix gas flow (N2, purified air, synthetic air). Under such conditions the pure substance permeates at constant rate into the matrix gas and can be diluted thereafter to the desired amount fractions in one or two subsequent steps. The permeation rate (mass loss over time) of the permeation tube is precisely calibrated in a fully traceable magnetic suspension balance. The carrier gas is previously purified from the compounds of interest using commercially available purification cartridges. The permeation chambers of ReGaS2 and ReGaS3 have multiple individual cells allowing for the generation of mixtures containing up to 5 different components if required. ReGaS1 allows for the generation of one-component mixtures only. These primary mixtures are then diluted to the required amount of substance fractions using thermal mass flow controllers for full flexibility and adaptability of the generation process over the entire range of possible concentrations. In order to considerably reduce adsorption/desorption processes and thus stabilisation time, all electro-polished stainless steel parts of ReGaS1 and ReGaS2 in contact with the reference gas mixtures are passivated with SilcoNert2000® surface coating. These three state-of-the-art mobile reference gas generators are applicable under both, laboratory and field conditions. Moreover the dynamic generation method can be adapted and applied to a large variety of molecules (e.g. BTEX, CFCs, HCFCs, HFCs and other refrigerants) and is particularly suitable for reactive gas species and/or at concentration ranges which are unstable when stored in pressurised cylinders. Acknowledgement: This work was supported by the European Metrology Research Programme (EMRP). The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union

  20. Estimated United States Residential Energy Use in 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, C A; Johnson, D M; Simon, A J

    2011-12-12

    A flow chart depicting energy flow in the residential sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 11,000 trillion British Thermal Units (trBTUs) of electricity and fuels were used throughout the United States residential sector in lighting, electronics, air conditioning, space heating, water heating, washing appliances, cooking appliances, refrigerators, and other appliances. The residential sector is powered mainly by electricity and natural gas. Other fuels used include petroleum products (fuel oil, liquefied petroleum gas and kerosene), biomass (wood), and on-premises solar, wind, and geothermal energy.more » The flow patterns represent a comprehensive systems view of energy used within the residential sector.« less

  1. Development of a computer code for calculating the steady super/hypersonic inviscid flow around real configurations. Volume 1: Computational technique

    NASA Technical Reports Server (NTRS)

    Marconi, F.; Salas, M.; Yaeger, L.

    1976-01-01

    A numerical procedure has been developed to compute the inviscid super/hypersonic flow field about complex vehicle geometries accurately and efficiently. A second order accurate finite difference scheme is used to integrate the three dimensional Euler equations in regions of continuous flow, while all shock waves are computed as discontinuities via the Rankine Hugoniot jump conditions. Conformal mappings are used to develop a computational grid. The effects of blunt nose entropy layers are computed in detail. Real gas effects for equilibrium air are included using curve fits of Mollier charts. Typical calculated results for shuttle orbiter, hypersonic transport, and supersonic aircraft configurations are included to demonstrate the usefulness of this tool.

  2. Development of a computer code for calculating the steady super/hypersonic inviscid flow around real configurations. Volume 2: Code description

    NASA Technical Reports Server (NTRS)

    Marconi, F.; Yaeger, L.

    1976-01-01

    A numerical procedure was developed to compute the inviscid super/hypersonic flow field about complex vehicle geometries accurately and efficiently. A second-order accurate finite difference scheme is used to integrate the three-dimensional Euler equations in regions of continuous flow, while all shock waves are computed as discontinuities via the Rankine-Hugoniot jump conditions. Conformal mappings are used to develop a computational grid. The effects of blunt nose entropy layers are computed in detail. Real gas effects for equilibrium air are included using curve fits of Mollier charts. Typical calculated results for shuttle orbiter, hypersonic transport, and supersonic aircraft configurations are included to demonstrate the usefulness of this tool.

  3. A Computer Code for Swirling Turbulent Axisymmetric Recirculating Flows in Practical Isothermal Combustor Geometries

    NASA Technical Reports Server (NTRS)

    Lilley, D. G.; Rhode, D. L.

    1982-01-01

    A primitive pressure-velocity variable finite difference computer code was developed to predict swirling recirculating inert turbulent flows in axisymmetric combustors in general, and for application to a specific idealized combustion chamber with sudden or gradual expansion. The technique involves a staggered grid system for axial and radial velocities, a line relaxation procedure for efficient solution of the equations, a two-equation k-epsilon turbulence model, a stairstep boundary representation of the expansion flow, and realistic accommodation of swirl effects. A user's manual, dealing with the computational problem, showing how the mathematical basis and computational scheme may be translated into a computer program is presented. A flow chart, FORTRAN IV listing, notes about various subroutines and a user's guide are supplied as an aid to prospective users of the code.

  4. Detector Based Realisation of Illuminance Scale at NML-SIRIM

    NASA Astrophysics Data System (ADS)

    Abdullah, Mohd Nizam; Abidin, Mohd Nasir Zainal; Abidin, Abdul Rashid Zainal; Shaari, Sahbudin

    2009-07-01

    Illuminance scale is one of the fundamentals in the realisation of candela in optical radiation. The en route of the realisation is based on the fundamental process from the unbroken chain of traceability which includes from the primary standard disseminated to working standard and lastly the end user. There are many variations towards this realisation even though some of the national metrology institutes (NMI) does not have the primary standard but their traceability still valid. The realisation of National Metrology Laboratory SIRIM (NML-SIRIM), Malaysia illuminance scale is based on detector. The scale is traceable to National Physical Labortaory (NPL), United Kingdom (UK) by annually calibrating photometers and luminous intensity lamp. This paper describes measurement method and the system set-up was previously crosschecked with Korea Research Institute Standards and Science (KRISS), Republic of Korea. The agreement between both laboratories is within 0.5% the uncertainty maintained at NML-SIRIM. Furthermore, the basic measurement equation for illuminance realisation is also derived.

  5. Procedures for establishing and maintaining consistent air-kerma strength standards for low-energy, photon-emitting brachytherapy sources: recommendations of the Calibration Laboratory Accreditation Subcommittee of the American Association of Physicists in Medicine.

    PubMed

    DeWerd, Larry A; Huq, M Saiful; Das, Indra J; Ibbott, Geoffrey S; Hanson, William F; Slowey, Thomas W; Williamson, Jeffrey F; Coursey, Bert M

    2004-03-01

    Low dose rate brachytherapy is being used extensively for the treatment of prostate cancer. As of September 2003, there are a total of thirteen 125I and seven 103Pd sources that have calibrations from the National Institute of Standards and Technology (NIST) and the Accredited Dosimetry Calibration Laboratories (ADCLs) of the American Association of Physicists in Medicine (AAPM). The dosimetry standards for these sources are traceable to the NIST wide-angle free-air chamber. Procedures have been developed by the AAPM Calibration Laboratory Accreditation Subcommittee to standardize quality assurance and calibration, and to maintain the dosimetric traceability of these sources to ensure accurate clinical dosimetry. A description of these procedures is provided to the clinical users for traceability purposes as well as to provide guidance to the manufacturers of brachytherapy sources and ADCLs with regard to these procedures.

  6. Traceability and Quality Control in Traditional Chinese Medicine: From Chemical Fingerprint to Two-Dimensional Barcode.

    PubMed

    Cai, Yong; Li, Xiwen; Li, Mei; Chen, Xiaojia; Hu, Hao; Ni, Jingyun; Wang, Yitao

    2015-01-01

    Chemical fingerprinting is currently a widely used tool that enables rapid and accurate quality evaluation of Traditional Chinese Medicine (TCM). However, chemical fingerprints are not amenable to information storage, recognition, and retrieval, which limit their use in Chinese medicine traceability. In this study, samples of three kinds of Chinese medicines were randomly selected and chemical fingerprints were then constructed by using high performance liquid chromatography. Based on chemical data, the process of converting the TCM chemical fingerprint into two-dimensional code is presented; preprocess and filtering algorithm are also proposed aiming at standardizing the large amount of original raw data. In order to know which type of two-dimensional code (2D) is suitable for storing data of chemical fingerprints, current popular types of 2D codes are analyzed and compared. Results show that QR Code is suitable for recording the TCM chemical fingerprint. The fingerprint information of TCM can be converted into data format that can be stored as 2D code for traceability and quality control.

  7. Combination of watermarking and joint watermarking-decryption for reliability control and traceability of medical images.

    PubMed

    Bouslimi, D; Coatrieux, G; Cozic, M; Roux, Ch

    2014-01-01

    In this paper, we propose a novel crypto-watermarking system for the purpose of verifying the reliability of images and tracing them, i.e. identifying the person at the origin of an illegal distribution. This system couples a common watermarking method, based on Quantization Index Modulation (QIM), and a joint watermarking-decryption (JWD) approach. At the emitter side, it allows the insertion of a watermark as a proof of reliability of the image before sending it encrypted; at the reception, another watermark, a proof of traceability, is embedded during the decryption process. The scheme we propose makes interoperate such a combination of watermarking approaches taking into account risks of interferences between embedded watermarks, allowing the access to both reliability and traceability proofs. Experimental results confirm the efficiency of our system, and demonstrate it can be used to identify the physician at the origin of a disclosure even if the image has been modified.

  8. PGI chicory (Cichorium intybus L.) traceability by means of HRMAS-NMR spectroscopy: a preliminary study.

    PubMed

    Ritota, Mena; Casciani, Lorena; Valentini, Massimiliano

    2013-05-01

    Analytical traceability of PGI and PDO foods (Protected Geographical Indication and Protected Denomination Origin respectively) is one of the most challenging tasks of current applied research. Here we proposed a metabolomic approach based on the combination of (1)H high-resolution magic angle spinning-nuclear magnetic resonance (HRMAS-NMR) spectroscopy with multivariate analysis, i.e. PLS-DA, as a reliable tool for the traceability of Italian PGI chicories (Cichorium intybus L.), i.e. Radicchio Rosso di Treviso and Radicchio Variegato di Castelfranco, also known as red and red-spotted, respectively. The metabolic profile was gained by means of HRMAS-NMR, and multivariate data analysis allowed us to build statistical models capable of providing clear discrimination among the two varieties and classification according to the geographical origin. Based on Variable Importance in Projection values, the molecular markers for classifying the different types of red chicories analysed were found accounting for both the cultivar and the place of origin. © 2012 Society of Chemical Industry.

  9. Traceability of 'Limone di Siracusa PGI' by a multidisciplinary analytical and chemometric approach.

    PubMed

    Amenta, M; Fabroni, S; Costa, C; Rapisarda, P

    2016-11-15

    Food traceability is increasingly relevant with respect to safety, quality and typicality issues. Lemon fruits grown in a typical lemon-growing area of southern Italy (Siracusa), have been awarded the PGI (Protected Geographical Indication) recognition as 'Limone di Siracusa'. Due to its peculiarity, consumers have an increasing interest about this product. The detection of potential fraud could be improved by using the tools linking the composition of this production to its typical features. This study used a wide range of analytical techniques, including conventional techniques and analytical approaches, such as spectral (NIR spectra), multi-elemental (Fe, Zn, Mn, Cu, Li, Sr) and isotopic ((13)C/(12)C, (18)O/(16)O) marker investigations, joined with multivariate statistical analysis, such as PLS-DA (Partial Least Squares Discriminant Analysis) and LDA (Linear Discriminant Analysis), to implement a traceability system to verify the authenticity of 'Limone di Siracusa' production. The results demonstrated a very good geographical discrimination rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Genetic characterization of Italian tomato varieties and their traceability in tomato food products-Sardaro-2012-Food Science & Nutrition-Wiley Online Library

    PubMed Central

    Sardaro, Maria Luisa Savo; Marmiroli, Marta; Maestri, Elena; Marmiroli, Nelson

    2013-01-01

    Genetic diversity underlies the improvement of crops by plant breeding. Landraces of tomato (Solanum lycopersicum L.) can contain valuable alleles not common in modern germplasms. The aim was to measure genetic diversity present in 47 most common tomato varieties grown in Italy, 35 were varieties used for processing and 12 were landraces considered “salad varieties”. Furthermore, we demonstrated the possibility that the variety traceability can be extended through the entire production chain. Diversity was measured using 11 microsatellite markers and 94 genotypes. Among the markers used, a total of 48 alleles were detected. A dendrogram based on total microsatellite polymorphism grouped 47 varieties into three major clusters at 0.75 similarity coefficient, differentiating the modern varieties from tomatoes landraces. The DNA markers developed confirmed the possibility to support the genotype identification all along the tomato production chain. The number of alleles and genotypes identified in the present work is the largest considering papers on food traceability. PMID:24804014

  11. Genetic characterization of Italian tomato varieties and their traceability in tomato food products-Sardaro-2012-Food Science & Nutrition-Wiley Online Library.

    PubMed

    Sardaro, Maria Luisa Savo; Marmiroli, Marta; Maestri, Elena; Marmiroli, Nelson

    2013-01-01

    Genetic diversity underlies the improvement of crops by plant breeding. Landraces of tomato (Solanum lycopersicum L.) can contain valuable alleles not common in modern germplasms. The aim was to measure genetic diversity present in 47 most common tomato varieties grown in Italy, 35 were varieties used for processing and 12 were landraces considered "salad varieties". Furthermore, we demonstrated the possibility that the variety traceability can be extended through the entire production chain. Diversity was measured using 11 microsatellite markers and 94 genotypes. Among the markers used, a total of 48 alleles were detected. A dendrogram based on total microsatellite polymorphism grouped 47 varieties into three major clusters at 0.75 similarity coefficient, differentiating the modern varieties from tomatoes landraces. The DNA markers developed confirmed the possibility to support the genotype identification all along the tomato production chain. The number of alleles and genotypes identified in the present work is the largest considering papers on food traceability.

  12. Assessment of Recovery of Milk Protein Allergens from Processed Food for Mass Spectrometry Quantification.

    PubMed

    Groves, Kate; Cryar, Adam; Walker, Michael; Quaglia, Milena

    2018-01-01

    Assessing the recovery of food allergens from solid processed matrixes is one of the most difficult steps that needs to be overcome to enable the accurate quantification of protein allergens by immunoassay and MS. A feasibility study is described herein applying International System of Units (SI)-traceably quantified milk protein solutions to assess recovery by an improved extraction method. Untargeted MS analysis suggests that this novel extraction method can be further developed to provide high recoveries for a broad range of food allergens. A solution of α-casein was traceably quantified to the SI for the content of α-S1 casein. Cookie dough was prepared by spiking a known amount of the SI-traceable quantified solution into a mixture of flour, sugar, and soya spread, followed by baking. A novel method for the extraction of protein food allergens from solid matrixes based on proteolytic digestion was developed, and its performance was compared with the performance of methods reported in the literature.

  13. Authenticity and traceability of vanilla flavors by analysis of stable isotopes of carbon and hydrogen.

    PubMed

    Hansen, Anne-Mette Sølvbjerg; Fromberg, Arvid; Frandsen, Henrik Lauritz

    2014-10-22

    Authenticity and traceability of vanilla flavors were investigated using gas chromatography-isotope ratio mass spectrometry (GC-IRMS). Vanilla flavors produced by chemical synthesis (n = 2), fermentation (n = 1), and extracted from two different species of the vanilla orchid (n = 79) were analyzed. The authenticity of the flavor compound vanillin was evaluated on the basis of measurements of ratios of carbon stable isotopes (δ(13)C). It was found that results of δ(13)C for vanillin extracted from Vanilla planifolia and Vanilla tahitensis were significantly different (t test) and that it was possible to differentiate these two groups of natural vanillin from vanillin produced otherwise. Vanilla flavors were also analyzed for ratios of hydrogen stable isotopes (δ(2)H). A graphic representation of δ(13)C versus δ(2)H revealed that vanillin extracted from pods grown in adjacent geographic origins grouped together. Accordingly, values of δ(13)C and δ(2)H can be used for studies of authenticity and traceability of vanilla flavors.

  14. Nuclear reference materials to meet the changing needs of the global nuclear community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, H.R.; Gradle, C.G.; Narayanan, U.I.

    New Brunswick Laboratory (NBL) serves as the U.S. Government`s certifying authority for nuclear reference materials and measurement calibration standards. In this role, NBL provides nuclear reference materials certified for chemical and/or isotopic compositions traceable to a nationally accepted, internationally compatible reference base. Emphasis is now changing as to the types of traceable nuclear reference materials needed as operations change within the Department of Energy complex and at nuclear facilities around the world. New challenges include: environmental and waste minimization issues, facilities and materials transitioning from processing to storage modes with corresponding changes in the types of measurements being performed, emphasismore » on requirements for characterization of waste materials, and difficulties in transporting nuclear materials and international factors, including IAEA influences. During these changing times, it is critical that traceable reference materials be provided for calibration or validation of the performance of measurement systems. This paper will describe actions taken and planned to meet the changing reference material needs of the global nuclear community.« less

  15. From soil to grape and wine: Variation of light and heavy elements isotope ratios.

    PubMed

    Durante, Caterina; Bertacchini, Lucia; Bontempo, Luana; Camin, Federica; Manzini, Daniela; Lambertini, Paolo; Marchetti, Andrea; Paolini, Mauro

    2016-11-01

    In the development of a geographical traceability model, it is necessary to understand if the value of the monitored indicators in a food is correlated to its origin or if it is also influenced by 'external factors' such as those coming from its production. In this study, a deeper investigation of the trend of direct geographical traceability indicators along the winemaking process of two traditional oenological products was carried out. Different processes were monitored, sampling each step of their production (grape juice, intermediate products and wine). The results related to the determinations of δ(18)O, (D/H)I, (D/H)II, δ(13)C, δ(15)N and (87)Sr/(86)Sr have been reported. Furthermore, correspondence with the isotopic values coming from the respective soil and vine-branch samples have been investigated as well, showing the optimal traceability power of the monitored geographical tracers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. NGS tools for traceability in candies as high processed food products: Ion Torrent PGM versus conventional PCR-cloning.

    PubMed

    Muñoz-Colmenero, Marta; Martínez, Jose Luis; Roca, Agustín; Garcia-Vazquez, Eva

    2017-01-01

    The Next Generation Sequencing methodologies are considered the next step within DNA-based methods and their applicability in different fields is being evaluated. Here, we tested the usefulness of the Ion Torrent Personal Genome Machine (PGM) in food traceability analyzing candies as a model of high processed foods, and compared the results with those obtained by PCR-cloning-sequencing (PCR-CS). The majority of samples exhibited consistency between methodologies, yielding more information and species per product from the PGM platform than PCR-CS. Significantly higher AT-content in sequences of the same species was also obtained from PGM. This together with some taxonomical discrepancies between methodologies suggest that the PGM platform is still pre-mature for its use in food traceability of complex highly processed products. It could be a good option for analysis of less complex food, saving time and cost per sample. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Method for traceable measurement of LTE signals

    NASA Astrophysics Data System (ADS)

    Sunder Dash, Soumya; Pythoud, Frederic; Leuchtmann, Pascal; Leuthold, Juerg

    2018-04-01

    This contribution presents a reference setup to measure the power of the cell-specific resource elements present in downlink long term evolution (LTE) signals in a way that the measurements are traceable to the international system of units. This setup can be used to calibrate the LTE code-selective field probes that are used to measure the radiation of base stations for mobile telephony. It can also be used to calibrate LTE signal generators and receivers. The method is based on traceable scope measurements performed directly at the output of a measuring antenna. It implements offline digital signal processing demodulation algorithms that consider the digital down-conversion, timing synchronization, frequency synchronization, phase synchronization and robust LTE cell identification to produce the downlink time-frequency LTE grid. Experimental results on conducted test scenarios, both single-input-single-output and multiple-input-multiple-output antenna configuration, show promising results confirming measurement uncertainties of the order of 0.05 dB with a coverage factor of 2.

  18. Absolute sulfur isotope amount ratios in two batches of high purity SO2 gas: sulfur isotope reference materials IRMM-2012 and IRMM-2013

    NASA Astrophysics Data System (ADS)

    Valkiers, S.; Ding, T.; Ruße, K.; de Bièvre, P.; Taylor, P. D. P.

    2005-04-01

    SI-traceable ("absolute") values have been obtained for sulfur isotope amount ratios n(33S)/n(32S) and n(34S)/n(32S), in two batches of high purity SO2 gas (IRMM-2012 and IRMM-2013). The SO2 gas was converted at IMR-Beijing to Ag2S, then fluorinated to SF6 gas both at IMR-Beijing and at IRMM-Geel. Yields of different conversion methods exceeded 99%. The sulfur amount-of-substance measurements were performed by gas mass spectrometry on SF5+ ions using "IRMM's amount comparator II". These isotope amount ratios were calibrated by means of gravimetrically prepared synthetic mixtures of highly enriched sulfur isotopes (32S, 33S and 34S) in Ag2S form. The ratio values in the SO2 Secondary Measurement Standard are traceable to the SI system. They can be used in the calibration of field sulfur isotope measurements thus making these metrologically traceable to the SI.

  19. Acoustic emission transducers--development of a facility for traceable out-of-plane displacement calibration.

    PubMed

    Theobald, P D; Esward, T J; Dowson, S P; Preston, R C

    2005-03-01

    Acoustic emission (AE) is a widely used technique that has been employed for the integrity testing of a range of vessels and structures for many years. The last decade has seen advances in signal processing, such that the reliability of AE technology is now being recognised by a wider range of industries. Furthermore, the need for quality control at the manufacturing stage, and requirements of in-service testing, is encouraging the issue of traceable measurements to be addressed. Currently, no independent calibration service for acoustic emission transducers is available within Europe. The UKs National Physical Laboratory (NPL) is undertaking work to develop a measurement facility for the traceable calibration of AE sensors. Such calibrations can contribute to greater acceptance of AE techniques in general, by meeting quality system and other traceability requirements. In this paper the key issues surrounding the development of such a facility are reviewed, including the need to establish repeatable AE sources, select suitable test blocks and to understand the limitations imposed by AE sensors themselves. To provide an absolute measurement of the displacement on the surface of a test block, laser interferometry is employed. In this way the output voltage of an AE sensor can be directly related to the displacement detected at the block surface. A possible calibration methodology is discussed and preliminary calibration results are presented for a commercially available AE sensor, showing its response to longitudinal wave modes.

  20. Harmonisation of seven common enzyme results through EQA.

    PubMed

    Weykamp, Cas; Franck, Paul; Gunnewiek, Jacqueline Klein; de Jonge, Robert; Kuypers, Aldy; van Loon, Douwe; Steigstra, Herman; Cobbaert, Christa

    2014-11-01

    Equivalent results between different laboratories enable optimal patient care and can be achieved with harmonisation. We report on EQA-initiated national harmonisation of seven enzymes using commutable samples. EQA samples were prepared from human serum spiked with human recombinant enzymes. Target values were assigned with the IFCC Reference Measurement Procedures. The same samples were included at four occasions in the EQA programmes of 2012 and 2013. Laboratories were encouraged to report IFCC traceable results. A parallel study was done to confirm commutability of the samples. Of the 223 participating laboratories, 95% reported IFCC traceable results, ranging from 98% (ASAT) to 87% (amylase). Users of Roche and Siemens (97%) more frequently reported in IFCC traceable results than users of Abbott (91%), Beckman (90%), and Olympus (87%). The success of harmonisation, expressed as the recovery of assigned values and the inter-laboratory CV was: ALAT (recovery 100%; inter-lab CV 4%), ASAT (102%; 4%), LD (98%; 3%), CK (101%; 5%), GGT (98%; 4%), AP (96%; 6%), amylase (99%; 4%). There were no significant differences between the manufacturers. Commutability was demonstrated in the parallel study. Equal results in the same sample in the 2012 and 2013 EQA programmes demonstrated stability of the samples. The EQA-initiated national harmonisation of seven enzymes, using stable, commutable human serum samples, spiked with human recombinant enzymes, and targeted with the IFCC Reference Measurement Procedures, was successful in terms of implementation of IFCC traceable results (95%), recovery of the target (99%), and inter-laboratory CV (4%).

  1. [Report of the NEDO project "Research and development to promote the creation and utilization of an intellectual infrastructure: development of reference materials for laboratory medicine" "Development of pure substance-type certified reference materials"].

    PubMed

    Takatsu, Akiko

    2009-06-01

    There is an increasing demand to establish a metrological traceability system for in vitro diagnostics and medical devices. Pure substance-type reference materials are playing key roles in metrological traceability, because they form the basis for many traceability chains in chemistry. The National Metrology Institute of Japan (NMIJ), in the National Institute of Advanced Industrial Science and Technology (AIST), has been developing purity-certified reference materials (CRMs) in this field, such as cholesterol, creatinine, and urea. In the New Energy and Industrial Technology Development Organization (NEDO) project, entitled: "Research and Development to Promote the Creation and Utilization of an Intellectual Infrastructure: Development of Reference Materials for Laboratory Medicine", several pure substance-type CRMs were developed. For a pure protein solution CRM, amino acid analysis and nitrogen determination were chosen as the certification methods. The development and certification processes for the C-reactive protein (CRP) solution CRM were completed, with the recombinant human CRP solution as a candidate material. This CRP solution CRM is now available as NMIJ CRM. For cortisol CRM, a purified candidate material and highly pure primary reference material were prepared. Each impure compound in the materials was identified and quantified. The pure cortisol CRM will be available in 2009. These two CRMs provide a traceability link between routine clinical methods and the SI unit.

  2. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    NASA Astrophysics Data System (ADS)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  3. Determination of wind from NIMBUS 6 satellite sounding data

    NASA Technical Reports Server (NTRS)

    Carle, W. E.; Scoggins, J. R.

    1981-01-01

    Objective methods of computing upper level and surface wind fields from NIMBUS 6 satellite sounding data are developed. These methods are evaluated by comparing satellite derived and rawinsonde wind fields on gridded constant pressure charts in four geographical regions. Satellite-derived and hourly observed surface wind fields are compared. Results indicate that the best satellite-derived wind on constant pressure charts is a geostrophic wind derived from highly smoothed fields of geopotential height. Satellite-derived winds computed in this manner and rawinsonde winds show similar circulation patterns except in areas of small height gradients. Magnitudes of the standard deviation of the differences between satellite derived and rawinsonde wind speeds range from approximately 3 to 12 m/sec on constant pressure charts and peak at the jet stream level. Fields of satellite-derived surface wind computed with the logarithmic wind law agree well with fields of observed surface wind in most regions. Magnitudes of the standard deviation of the differences in surface wind speed range from approximately 2 to 4 m/sec, and satellite derived surface winds are able to depict flow across a cold front and around a low pressure center.

  4. Angina Relief by Ranolazine Identifies False-Negative SPECT Myocardial Perfusion Scans in Patients with Coronary Disease Demonstrated by Coronary Angiography.

    PubMed

    Murray, Gary L

    2014-09-01

    Normal myocardial perfusion imaging (MPI) reduces intermediate- or high-risk pretest probability patients to low- or intermediate-risk posttest probability, respectively, for coronary disease (CD). Since ranolazine (RAN) relieves only angina, anginal patients with normal MPI whose angina is relieved by RAN present a significant dilemma. The purpose of this retrospective chart review was to confirm the impression that coronary angiography (CA) is indicated in patients whose class 3 to 4 angina is relieved by RAN, but have normal myocardial single-photon emission computed tomography (SPECT) MPIs. Charts of patients with stable class 3 to 4 angina (typical and atypical) and normal MPIs (left ventricular ejection fraction [LVEF] ≥50% and segmental score = 0) were reviewed. CA was done on all the patients with complete angina relief taking RAN, as well as nonresponders whose anginal etiology could not be explained. Stenoses were considered flow-restrictive when more than 70% diameter stenosis is observed by quantitative CA, or, when 50 to 70%, fractional flow reserve (FFR) measured ≤0.80. RAN relieved angina in 36 of 54 (67%) patients. Of the known cases, 25 of these 36 (69%) had 43 stenoses ≥50% (mean = 66%): 15 (60%) had 1 vessel disease; 9 (36%) had multivessel disease; 18 (72%) had left anterior descending (LAD) disease; 1 (4%) had left main disease. Twenty one of 43 (49%) stenosis were > 70%; 22 (51%) stenoses were 50 to 70% and required FFR measurement. Twenty nine of 43 stenoses (67%) were considered flow-restrictive in 18 of these 25 (72%) patients. Eight RAN nonresponders with no explanation for angina had no CD at CA. RAN angina relief is invaluable in identifying falsely negative SPECT MPI, and 50% of these patients have flow-restrictive stenoses.

  5. Making large amounts of meteorological plots easily accessible to users

    NASA Astrophysics Data System (ADS)

    Lamy-Thepaut, Sylvie; Siemen, Stephan; Sahin, Cihan; Raoult, Baudouin

    2015-04-01

    The European Centre for Medium-Range Weather Forecasts (ECMWF) is an international organisation providing its member organisations with forecasts in the medium time range of 3 to 15 days, and some longer-range forecasts for up to a year ahead, with varying degrees of detail. As part of its mission, ECMWF generates an increasing number of forecast data products for its users. To support the work of forecasters and researchers and to let them make best use of ECMWF forecasts, the Centre also provides tools and interfaces to visualise their products. This allows users to make use of and explore forecasts without having to transfer large amounts of raw data. This is especially true for products based on ECMWF's 50 member ensemble forecast, where some specific processing and visualisation are applied to extract information. Every day, thousands of raw data are being pushed to the ECMWF's interactive web charts application called ecCharts, and thousands of products are processed and pushed to ECMWF's institutional web site ecCharts provides a highly interactive application to display and manipulate recent numerical forecasts to forecasters in national weather services and ECMWF's commercial customers. With ecCharts forecasters are able to explore ECMWF's medium-range forecasts in far greater detail than has previously been possible on the web, and this as soon as the forecast becomes available. All ecCharts's products are also available through a machine-to-machine web map service based on the OGC Web Map Service (WMS) standard. ECMWF institutional web site provides access to a large number of graphical products. It was entirely redesigned last year. It now shares the same infrastructure as ECMWF's ecCharts, and can benefit of some ecCharts functionalities, for example the dashboard. The dashboard initially developed for ecCharts allows users to organise their own collection of products depending on their work flow, and is being further developed. In its first implementation, It presents the user's products in a single interface with fast access to the original product, and possibilities of synchronous animations between them. But its functionalities are being extended to give users the freedom to collect not only ecCharts's 2D maps and graphs, but also other ECMWF Web products such as monthly and seasonal products, scores, and observation monitoring. The dashboard will play a key role to help the user to interpret the large amount of information that ECMWF is providing. This talk will present examples of how the new user interface can organise complex meteorological maps and graphs and show the new possibilities users have gained by using the web as a medium.

  6. Integrated Analytical Evaluation and Optimization of Model Parameters against Preprocessed Measurement Data

    DTIC Science & Technology

    1989-06-23

    Iterations .......................... 86 3.2 Comparison between MACH and POLAR ......................... 90 3.3 Flow Chart for VSTS Algorithm...The most recent changes are: a) development of the VSTS (velocity space topology search) algorithm for calculating particle densities b) extension...with simple analytic models. The largest modification of the MACH code was the implementation of the VSTS procedure, which constituted a complete

  7. Numerical Implementation of Indicators and Statistical Control Tools in Monitoring and Evaluating CACEI-ISO Indicators of Study Program in Industrial Process by Systematization

    ERIC Educational Resources Information Center

    Ayala, Gabriela Cota; Real, Francia Angélica Karlos; Ivan, Ramirez Alvarado Edqar

    2016-01-01

    The research was conducted to determine if the study program of the career of industrial processes Technological University of Chihuahua, 1 year after that it was certified by CACEI, continues achieving the established indicators and ISO 9001: 2008, implementing quality tools, monitoring of essential indicators are determined, flow charts are…

  8. Real-Time Signal Processing Systems

    DTIC Science & Technology

    1992-10-29

    Programmer’s Model 50 15. Synchronization 67 16. Parameter Passage to Routines VIA Stacks 68 17. Typical VPH Activity Flow Chart 70 18. CPH...computing facilities to take advantage of cost effective solutions. A proliferation of different microprocessors and development systems spread among the... activities are completed, the roles of the VPH memory banks are reversed. This function-swapping is the primary reason, for the efficiency and high

  9. Las Matematicas: Lenguaje Universal. Nivel 1: Numeros y Numeracion (Mathematics: A Universal Language. Level 1: Numbers and Numeration).

    ERIC Educational Resources Information Center

    Dissemination and Assessment Center for Bilingual Education, Austin, TX.

    This is one of a series of student booklets designed for use in a bilingual mathematics program in grades 6-8. The general format is to present each page in both Spanish and English. The mathematical topics in this booklet include graphing on a number line, place value, using exponents, flow charts, and Roman numerals. (MK)

  10. Design of Training Systems, Phase II Report, Volume III; Model Program Descriptions and Operating Procedures. TAEG Report No. 12-2.

    ERIC Educational Resources Information Center

    Naval Training Equipment Center, Orlando, FL. Training Analysis and Evaluation Group.

    The Design of Training Systems (DOTS) project was initiated by the Department of Defense (DOD) to develop tools for the effective management of military training organizations. Volume 3 contains the model and data base program descriptions and operating procedures designed for phase 2 of the project. Flow charts and program listings for the…

  11. Host computer software specifications for a zero-g payload manhandling simulator

    NASA Technical Reports Server (NTRS)

    Wilson, S. W.

    1986-01-01

    The HP PASCAL source code was developed for the Mission Planning and Analysis Division (MPAD) of NASA/JSC, and takes the place of detailed flow charts defining the host computer software specifications for MANHANDLE, a digital/graphical simulator that can be used to analyze the dynamics of onorbit (zero-g) payload manhandling operations. Input and output data for representative test cases are contained.

  12. Subsurface-water flow and solute transport: federal glossary of selected terms

    USGS Publications Warehouse

    Isensee, Alan R.; Johnson, Lynn; Thornhill, Jerry; Nicholson, Thomas J.; Meyer, Gerald; Vecchioli, John; Laney, Robert

    1989-01-01

    The definitions and conversion charts are from two principal sources provided herein. The first is the 11Glossary11 compiled by A. I. Johnson in the 1981 report by the American Society of Testing and Materials titled Permeability and Groundwater Contaminant Transport. The second is Manu a 1 40, 11Ground-water Management, 11 produced by the American Society of Civil Engineers in 1985.

  13. RF multicoupler design techniques to minimize problems of corona, multipaction, and stability

    NASA Technical Reports Server (NTRS)

    Hurley, H. S.; Kozakoff, D. J.

    1971-01-01

    A mathematical expression was derived describing multipacting and corona effects in a coaxial cavity. Both mechanical and electrical design techniques were investigated to minimize the susceptibility of coaxial cavity to corona and multipacting-type breakdown. To assist in the design of a multicoupler free from corona and multipactor breakdown, a flow chart obtained from the derived mathematical expression is included.

  14. A real-time digital computer program for the simulation of a single rotor helicopter

    NASA Technical Reports Server (NTRS)

    Houck, J. A.; Gibson, L. H.; Steinmetz, G. G.

    1974-01-01

    A computer program was developed for the study of a single-rotor helicopter on the Langley Research Center real-time digital simulation system. Descriptions of helicopter equations and data, program subroutines (including flow charts and listings), real-time simulation system routines, and program operation are included. Program usage is illustrated by standard check cases and a representative flight case.

  15. Evaluation of a Technology for Teaching Complex Social Skills to Young Adults with Visual and Cognitive Impairments.

    ERIC Educational Resources Information Center

    Gumpel, Thomas P.; Nativ-Ari-Am, Hagit

    2001-01-01

    Two multiple baseline designs were used to evaluate a two-stage model for training four young adults with visual and cognitive impairments to grocery shop. A task-analytical flow chart of the behavioral skills involved in grocery shopping was used to increase completed skill steps and the number of correct items purchased. (Contains references.)…

  16. Documentation of a ground hydrology parameterization for use in the GISS atmospheric general circulation model

    NASA Technical Reports Server (NTRS)

    Lin, J. D.; Aleano, J.; Bock, P.

    1978-01-01

    The moisture transport processes related to the earth's surface relevant to the ground circulation model GCM are presented. The GHM parametrizations considered are: (1) ground wetness and soil parameters; (2) precipitation; (3) evapotranspiration; (4) surface storage of snow and ice; and (5) runout. The computational aspects of the GHM using computer programs and flow charts are described.

  17. Automatic Target Recognition Classification System Evaluation Methodology

    DTIC Science & Technology

    2002-09-01

    Testing Set of Two-Class XOR Data (250 Samples)......................................... 2-59 2.27 Decision Analysis Process Flow Chart...ROC curve meta - analysis , which is the estimation of the true ROC curve of a given diagnostic system through ROC analysis across many studies or...technique can be very effective in sensitivity analysis ; trying to determine which data points have the most effect on the solution, and in

  18. GPS Disciplined Oscillators for Traceability to the Italian Time Standard

    NASA Technical Reports Server (NTRS)

    Cordara, Franco; Pettiti, Valerio

    1996-01-01

    The Istituo Elettrotecnico Nazionale (IEN) is one of the Italian primary institutes which is responsible for the accreditation of secondary laboratories belong to the national calibration system (SNT) established by law in 1991. The Times and Frequency Department that has accredited in this frame 14 calibration centers for frequency, performs also the remote calibration of their reference oscillators by means of different synchronization systems. The problem of establishing the traceability of the national time standard of the Global Positioning System (GPS) disciplined oscillators has been investigated and the results obtained are reported.

  19. An RFID-Based Manufacturing Control Framework for Loosely Coupled Distributed Manufacturing System Supporting Mass Customization

    NASA Astrophysics Data System (ADS)

    Chen, Ruey-Shun; Tsai, Yung-Shun; Tu, Arthur

    In this study we propose a manufacturing control framework based on radio-frequency identification (RFID) technology and a distributed information system to construct a mass-customization production process in a loosely coupled shop-floor control environment. On the basis of this framework, we developed RFID middleware and an integrated information system for tracking and controlling the manufacturing process flow. A bicycle manufacturer was used to demonstrate the prototype system. The findings of this study were that the proposed framework can improve the visibility and traceability of the manufacturing process as well as enhance process quality control and real-time production pedigree access. Using this framework, an enterprise can easily integrate an RFID-based system into its manufacturing environment to facilitate mass customization and a just-in-time production model.

  20. Final report on CIPM key comparison CCM.FF-K6.2011: Comparison of the primary (national) standards of low-pressure gas flow

    NASA Astrophysics Data System (ADS)

    Benková, Miroslava; Makovnik, Stefan; Mickan, Bodo; Arias, Roberto; Chahine, Khaled; Funaki, Tatsuya; Li, Chunhui; Choi, Hae Man; Seredyuk, Denys; Su, Chun-Min; Windenberg, Christophe; Wright, John

    2014-01-01

    The comparison CCM.FF-K6.2011 was organized for the purpose of determination of the degree of equivalence of the national standards for low-pressure gas flow measurement over the range (2 to 100) m3/h. A rotary gas meter was used as a transfer standard. The measurements were provided at prescribed reference conditions. Eleven laboratories from four RMOs participated in this key comparison—EURAMET: PTB, Germany; SMU, Slovakia; LNE-LADG, France; SIM: NIST, USA; CENAM, Mexico; APMP: NMIJ AIST Japan; KRISS, Korea; NMI, Australia; NIM, China; CMS, Chinese Taipei; COOMET: GP GP Ivano-Frankivs'kstandart-metrologia, Ukraine and all participants reported independent traceability chains to the SI. All results were used in the determination of the key comparison reference value (KCRV) and the uncertainty of the KCRV. The reference value was determined at each flow separately following procedure A presented by M G Cox. The degree of equivalence with the KCRV was also calculated for each flow and laboratory. All reported results were consistent with the KCRV. This KCRV can now be used in the further regional comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Top