Precision Pointing Control System (PPCS) star tracker test
NASA Technical Reports Server (NTRS)
1972-01-01
Tests performed on the TRW precision star tracker are described. The unit tested was a two-axis gimballed star tracker designed to provide star LOS data to an accuracy of 1 to 2 sec. The tracker features a unique bearing system and utilizes thermal and mechanical symmetry techniques to achieve high precision which can be demonstrated in a one g environment. The test program included a laboratory evaluation of tracker functional operation, sensitivity, repeatibility, and thermal stability.
Kim, Junetae; Lim, Sanghee; Min, Yul Ha; Shin, Yong-Wook; Lee, Byungtae; Sohn, Guiyun; Jung, Kyung Hae; Lee, Jae-Ho; Son, Byung Ho; Ahn, Sei Hyun; Shin, Soo-Yong; Lee, Jong Won
2016-08-04
Mobile mental-health trackers are mobile phone apps that gather self-reported mental-health ratings from users. They have received great attention from clinicians as tools to screen for depression in individual patients. While several apps that ask simple questions using face emoticons have been developed, there has been no study examining the validity of their screening performance. In this study, we (1) evaluate the potential of a mobile mental-health tracker that uses three daily mental-health ratings (sleep satisfaction, mood, and anxiety) as indicators for depression, (2) discuss three approaches to data processing (ratio, average, and frequency) for generating indicator variables, and (3) examine the impact of adherence on reporting using a mobile mental-health tracker and accuracy in depression screening. We analyzed 5792 sets of daily mental-health ratings collected from 78 breast cancer patients over a 48-week period. Using the Patient Health Questionnaire-9 (PHQ-9) as the measure of true depression status, we conducted a random-effect logistic panel regression and receiver operating characteristic (ROC) analysis to evaluate the screening performance of the mobile mental-health tracker. In addition, we classified patients into two subgroups based on their adherence level (higher adherence and lower adherence) using a k-means clustering algorithm and compared the screening accuracy between the two groups. With the ratio approach, the area under the ROC curve (AUC) is 0.8012, indicating that the performance of depression screening using daily mental-health ratings gathered via mobile mental-health trackers is comparable to the results of PHQ-9 tests. Also, the AUC is significantly higher (P=.002) for the higher adherence group (AUC=0.8524) than for the lower adherence group (AUC=0.7234). This result shows that adherence to self-reporting is associated with a higher accuracy of depression screening. Our results support the potential of a mobile mental-health tracker as a tool for screening for depression in practice. Also, this study provides clinicians with a guideline for generating indicator variables from daily mental-health ratings. Furthermore, our results provide empirical evidence for the critical role of adherence to self-reporting, which represents crucial information for both doctors and patients.
Compensation for Time-Dependent Star Tracker Thermal Deformation on the Aqua Spacecraft
NASA Technical Reports Server (NTRS)
Hashmall, Joseph A.; Natanson, Gregory; Glickman, Jonathan; Sedlak, Joseph
2004-01-01
Analysis of attitude sensor data from the Aqua mission showed small but systematic differences between batch least-squares and extended Kalman filter attitudes. These differences were also found to be correlated with star tracker residuals, gyro bias estimates, and star tracker baseplate temperatures. This paper describes the analysis that shows that these correlations are all consistent with a single cause: time-dependent thermal deformation of star tracker alignments. These varying alignments can be separated into relative and common components. The relative misalignments can be determined and compensated for. The common misalignments can only be determined in special cases.
Kim, Junetae; Lim, Sanghee; Min, Yul Ha; Shin, Yong-Wook; Lee, Byungtae; Sohn, Guiyun; Jung, Kyung Hae; Lee, Jae-Ho; Son, Byung Ho; Ahn, Sei Hyun; Shin, Soo-Yong
2016-01-01
Background Mobile mental-health trackers are mobile phone apps that gather self-reported mental-health ratings from users. They have received great attention from clinicians as tools to screen for depression in individual patients. While several apps that ask simple questions using face emoticons have been developed, there has been no study examining the validity of their screening performance. Objective In this study, we (1) evaluate the potential of a mobile mental-health tracker that uses three daily mental-health ratings (sleep satisfaction, mood, and anxiety) as indicators for depression, (2) discuss three approaches to data processing (ratio, average, and frequency) for generating indicator variables, and (3) examine the impact of adherence on reporting using a mobile mental-health tracker and accuracy in depression screening. Methods We analyzed 5792 sets of daily mental-health ratings collected from 78 breast cancer patients over a 48-week period. Using the Patient Health Questionnaire-9 (PHQ-9) as the measure of true depression status, we conducted a random-effect logistic panel regression and receiver operating characteristic (ROC) analysis to evaluate the screening performance of the mobile mental-health tracker. In addition, we classified patients into two subgroups based on their adherence level (higher adherence and lower adherence) using a k-means clustering algorithm and compared the screening accuracy between the two groups. Results With the ratio approach, the area under the ROC curve (AUC) is 0.8012, indicating that the performance of depression screening using daily mental-health ratings gathered via mobile mental-health trackers is comparable to the results of PHQ-9 tests. Also, the AUC is significantly higher (P=.002) for the higher adherence group (AUC=0.8524) than for the lower adherence group (AUC=0.7234). This result shows that adherence to self-reporting is associated with a higher accuracy of depression screening. Conclusions Our results support the potential of a mobile mental-health tracker as a tool for screening for depression in practice. Also, this study provides clinicians with a guideline for generating indicator variables from daily mental-health ratings. Furthermore, our results provide empirical evidence for the critical role of adherence to self-reporting, which represents crucial information for both doctors and patients. PMID:27492880
Thermal Tracker: The Secret Lives of Bats and Birds Revealed
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Offshore wind developers and stakeholders can accelerate the sustainable, widespread deployment of offshore wind using a new open-source software program, called ThermalTracker. Researchers can now collect the data they need to better understand the potential effects of offshore wind turbines on bird and bat populations. This plug and play software can be used with any standard desktop computer, thermal camera, and statistical software to identify species and behaviors of animals in offshore locations.
A new mapping function in table-mounted eye tracker
NASA Astrophysics Data System (ADS)
Tong, Qinqin; Hua, Xiao; Qiu, Jian; Luo, Kaiqing; Peng, Li; Han, Peng
2018-01-01
Eye tracker is a new apparatus of human-computer interaction, which has caught much attention in recent years. Eye tracking technology is to obtain the current subject's "visual attention (gaze)" direction by using mechanical, electronic, optical, image processing and other means of detection. While the mapping function is one of the key technology of the image processing, and is also the determination of the accuracy of the whole eye tracker system. In this paper, we present a new mapping model based on the relationship among the eyes, the camera and the screen that the eye gazed. Firstly, according to the geometrical relationship among the eyes, the camera and the screen, the framework of mapping function between the pupil center and the screen coordinate is constructed. Secondly, in order to simplify the vectors inversion of the mapping function, the coordinate of the eyes, the camera and screen was modeled by the coaxial model systems. In order to verify the mapping function, corresponding experiment was implemented. It is also compared with the traditional quadratic polynomial function. And the results show that our approach can improve the accuracy of the determination of the gazing point. Comparing with other methods, this mapping function is simple and valid.
A New GPU-Enabled MODTRAN Thermal Model for the PLUME TRACKER Volcanic Emission Analysis Toolkit
NASA Astrophysics Data System (ADS)
Acharya, P. K.; Berk, A.; Guiang, C.; Kennett, R.; Perkins, T.; Realmuto, V. J.
2013-12-01
Real-time quantification of volcanic gaseous and particulate releases is important for (1) recognizing rapid increases in SO2 gaseous emissions which may signal an impending eruption; (2) characterizing ash clouds to enable safe and efficient commercial aviation; and (3) quantifying the impact of volcanic aerosols on climate forcing. The Jet Propulsion Laboratory (JPL) has developed state-of-the-art algorithms, embedded in their analyst-driven Plume Tracker toolkit, for performing SO2, NH3, and CH4 retrievals from remotely sensed multi-spectral Thermal InfraRed spectral imagery. While Plume Tracker provides accurate results, it typically requires extensive analyst time. A major bottleneck in this processing is the relatively slow but accurate FORTRAN-based MODTRAN atmospheric and plume radiance model, developed by Spectral Sciences, Inc. (SSI). To overcome this bottleneck, SSI in collaboration with JPL, is porting these slow thermal radiance algorithms onto massively parallel, relatively inexpensive and commercially-available GPUs. This paper discusses SSI's efforts to accelerate the MODTRAN thermal emission algorithms used by Plume Tracker. Specifically, we are developing a GPU implementation of the Curtis-Godson averaging and the Voigt in-band transmittances from near line center molecular absorption, which comprise the major computational bottleneck. The transmittance calculations were decomposed into separate functions, individually implemented as GPU kernels, and tested for accuracy and performance relative to the original CPU code. Speedup factors of 14 to 30× were realized for individual processing components on an NVIDIA GeForce GTX 295 graphics card with no loss of accuracy. Due to the separate host (CPU) and device (GPU) memory spaces, a redesign of the MODTRAN architecture was required to ensure efficient data transfer between host and device, and to facilitate high parallel throughput. Currently, we are incorporating the separate GPU kernels into a single function for calculating the Voigt in-band transmittance, and subsequently for integration into the re-architectured MODTRAN6 code. Our overall objective is that by combining the GPU processing with more efficient Plume Tracker retrieval algorithms, a 100-fold increase in the computational speed will be realized. Since the Plume Tracker runs on Windows-based platforms, the GPU-enhanced MODTRAN6 will be packaged as a DLL. We do however anticipate that the accelerated option will be made available to the general MODTRAN community through an application programming interface (API).
Sen. Paul, Rand [R-KY
2012-06-14
Senate - 06/14/2012 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Abnormal Vestibulo-Ocular Reflexes in Autism: A Potential Endophenotype
2014-08-01
among. Saccades and smooth pursuit are complex sensorimotor behaviors that involve several spatially distant brain regions and long- fiber tracts between...time, at a rate of 100 Hz. Visual stimuli were presented as a red laser -light, generated by NKI Pursuit Tracker® laser . The Pursuit Tracker® laser ...the testing equipment by projecting a laser stimulus onto the cylindrical screen and providing a fixed target at + 10º in both the horizontal and
NASA Astrophysics Data System (ADS)
Kroedel, Matthias; Zauner, Christoph
2017-09-01
The Meteosat Third Generation's extreme pointing requirements call for a highly stable bracket for mounting the Star Trackers. HB-Cesic®, a chopped fibre reinforced silicon carbide, was selected as a base material for the sensor bracket. The high thermal conductivity and low thermal expansion of HB-Cesic® were the key properties to fulfil the demanding thermo-elastic pointing requirements of below 1μrad/K for the Star Trackers mounting interfaces. Dominated by thermoelastic stability requirements, the design and analysis of the Bracket required a multidisciplinary approach with the focus on thermal and thermo-elastic analyses. Dedicated modal and thermal post-processing strategies have been applied in the scope of the light weighting process. The experimental verification of this thermo-elastic stable system has been a challenging task of its own. A thermo-elastic distortion measurement rig was developed with a stability of <0.1μrad/K in all three rotational degrees of freedom.
Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils.
Svedin, Bryant T; Beck, Michael J; Hadley, J Rock; Merrill, Robb; de Bever, Joshua T; Bolster, Bradley D; Payne, Allison; Parker, Dennis L
2017-06-01
To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Tracking through laser-induced clutter for air-to-ground directed energy system
NASA Astrophysics Data System (ADS)
Belen'kii, Mikhail; Brinkley, Timothy; Hughes, Kevin; Tannenbaum, Allen
2003-09-01
The agility and speed with which directed energy can be retargeted and delivered to the target makes a laser weapon highly desirable in tactical battlefield environments. A directed energy system can effectively damage and possibly destroy relatively soft targets on the ground. In order to accurately point a high-energy beam at the target, the directed energy system must be able to acquire and track targets of interest in highly cluttered environments, under different weather, smoke, and camouflage conditions and in the presence of turbulence and thermal blooming. To meet these requirements, we proposed a concept of a multi spectral tracker, which integrates three sensors: SAR radar, a passive MWIR optical tracker, and a range-gated laser illuminated tracker. In this paper we evaluated the feasibility of the integrated optical tracker and arrived to the following conclusions: a) the contrast enhancement by mapping the original pixel distribution to the desired one enhances the target identification capability, b) a reduction of the divergence of the illuminating beam reduces rms pointing error of a laser tracker, c) a clutter removal algorithm based on active contours is capable of capturing targets in highly cluttered environments, d) the daytime rms pointing error caused by anisoplanatism of the track point to the aim point is comparable to the diffraction-limited beam spot size, f) the peak intensity shift from the optical axis caused by thermal blooming at 5 km range for the air-to-ground engagement scenario is on the order of 8 μrad, and it is 10 μrad at 10 km range, and e) the thermal blooming reduces the peak average power in a 2 cm bucket at 5 km range by a factor of 8, and it reduces the peak average power in the bucket at 10 km range by a factor of 22.
Passive Sun seeker/tracker and a thermally activated power module
NASA Technical Reports Server (NTRS)
Siebert, C. J.; Morris, F. A.
1984-01-01
Development and testing of two mechanisms using a shape memory alloy metal (NITINOL) as the power source are described. The two mechanisms developed are a passive Sun Seeker/Tracker and a generic type power module. These mechanisms use NITINOL wire initially strained in pure torsion which provides the greatest mechanical work capacity upon recovery, as compared to other deformation modes (i.e., tension, helical springs, and bending).
Guaranteeing Airport Physical Screening Standards Act
Rep. Lowey, Nita M. [D-NY-18
2010-07-30
House - 08/26/2010 Referred to the Subcommittee on Transportation Security and Infrastructure Protection. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Nease, Donald E.; Ruffin, Mack T.; Klinkman, Michael S.; Jimbo, Masahito; Braun, Thomas M.; Underwood, Jennifer M.
2015-01-01
Background Computerized reminder systems (CRS) show promise for increasing preventive services such as colorectal cancer (CRC) screening. However, prior research has not evaluated a generalizable CRS across diverse, community primary care practices. We evaluated whether a generalizable CRS, ClinfoTracker, could improve screening rates for CRC in diverse primary care practices. Methods The study was a prospective trial to evaluate ClinfoTracker using historical control data in 12 Great Lakes Research In Practice Network community-based, primary care practices distributed from Southeast to Upper Peninsula Michigan. Our outcome measures were pre- and post-study practice-level CRC screening rates among patients seen during the 9-month study period. Ability to maintain the CRS was measured by days of reminder printing. Field notes were used to examine each practice’s cohesion and technology capabilities. Results All but one practice increased their CRC screening rates, ranging from 3.3% to 16.8% improvement. t tests adjusted for within practice correlation showed improvement in screening rates across all 12 practices, from 41.7% to 50.9%, P = 0.002. Technology capabilities impacted printing days (74% for high technology vs. 45% for low technology practices, P = 0.01), and cohesion demonstrated an impact trend for screening (15.3% rate change for high cohesion vs. 7.9% for low cohesion practices). Conclusions Implementing a generalizable CRS in diverse primary care practices yielded significant improvements in CRC screening rates. Technology capabilities are important in maintaining the system, but practice cohesion may have a greater influence on screening rates. This work has important implications for practices implementing reminder systems. PMID:18725836
CO2 evaporative cooling: The future for tracking detector thermal management
NASA Astrophysics Data System (ADS)
Tropea, P.; Daguin, J.; Petagna, P.; Postema, H.; Verlaat, B.; Zwalinski, L.
2016-07-01
In the last few years, CO2 evaporative cooling has been one of the favourite technologies chosen for the thermal management of tracking detectors at LHC. ATLAS Insertable B-Layer and CMS Pixel phase 1 upgrade have adopted it and their systems are now operational or under commissioning. The CERN PH-DT team is now merging the lessons learnt on these two systems in order to prepare the design and construction of the cooling systems for the new Upstream Tracker and the Velo upgrade in LHCb, due by 2018. Meanwhile, the preliminary design of the ATLAS and CMS full tracker upgrades is started, and both concepts heavily rely on CO2 evaporative cooling. This paper highlights the performances of the systems now in operation and the challenges to overcome in order to scale them up to the requirements of the future generations of trackers. In particular, it focuses on the conceptual design of a new cooling system suited for the large phase 2 upgrade programmes, which will be validated with the construction of a common prototype in the next years.
DOE Office of Scientific and Technical Information (OSTI.GOV)
The software processes recorded thermal video and detects the flight tracks of birds and bats that passed through the camera's field of view. The output is a set of images that show complete flight tracks for any detections, with the direction of travel indicated and the thermal image of the animal delineated. A report of the descriptive features of each detected track is also output in the form of a comma-separated value text file.
Robust infrared target tracking using discriminative and generative approaches
NASA Astrophysics Data System (ADS)
Asha, C. S.; Narasimhadhan, A. V.
2017-09-01
The process of designing an efficient tracker for thermal infrared imagery is one of the most challenging tasks in computer vision. Although a lot of advancement has been achieved in RGB videos over the decades, textureless and colorless properties of objects in thermal imagery pose hard constraints in the design of an efficient tracker. Tracking of an object using a single feature or a technique often fails to achieve greater accuracy. Here, we propose an effective method to track an object in infrared imagery based on a combination of discriminative and generative approaches. The discriminative technique makes use of two complementary methods such as kernelized correlation filter with spatial feature and AdaBoost classifier with pixel intesity features to operate in parallel. After obtaining optimized locations through discriminative approaches, the generative technique is applied to determine the best target location using a linear search method. Unlike the baseline algorithms, the proposed method estimates the scale of the target by Lucas-Kanade homography estimation. To evaluate the proposed method, extensive experiments are conducted on 17 challenging infrared image sequences obtained from LTIR dataset and a significant improvement of mean distance precision and mean overlap precision is accomplished as compared with the existing trackers. Further, a quantitative and qualitative assessment of the proposed approach with the state-of-the-art trackers is illustrated to clearly demonstrate an overall increase in performance.
Horizon Detection In The Visible Spectrum
2016-09-01
techniques can also recognize star patterns in star trackers for satellite attitude determination. Horizon detection in the visible spectrum was largely...discarded for attitude determination in favor of thermal imagery, due to the greater consistency of the earth’s thermal radiation. This thesis...in 85% of the tested image set. 14. SUBJECT TERMS attitude determination, machine learning, image classification, earth horizon sensor, computer
"Sturdy as a house with four windows," the star tracker of the future
NASA Astrophysics Data System (ADS)
Duivenvoorde, Tom; Leijtens, Johan; van der Heide, Erik J.
2017-11-01
Ongoing miniaturization of spacecraft demands the reduction in size of Attitude and Orbit Control Systems (AOCS). Therefore TNO has created a new design of a multi aperture, high performance, and miniaturized star tracker. The innovative design incorporates the latest developments in camera technology, attitude calculation and mechanical design into a system with 5 arc seconds accuracy, making the system usable for many applications. In this paper the results are presented of the system design and analysis, as well as the performance predictions for the Multi Aperture Baffled Star Tracker (MABS). The highly integrated system consists of multiple apertures without the need for external baffles, resulting in major advantages in mass, volume, alignment with the spacecraft and relative aperture stability. In the analysis part of this paper, the thermal and mechanical stability are discussed. In the final part the simulation results will be described that have lead to the predicted accuracy of the star tracker system and a peek into the future of attitude sensors is given.
Prostate Research, Outreach, Screening, Testing, Access, and Treatment Effectiveness Act of 2010
Sen. Tester, Jon [D-MT
2010-09-14
Senate - 09/14/2010 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Monitoring the performance of the Southern African Large Telescope
NASA Astrophysics Data System (ADS)
Hettlage, Christian; Coetzee, Chris; Väisänen, Petri; Romero Colmenero, Encarni; Crawford, Steven M.; Kotze, Paul; Rabe, Paul; Hulme, Stephen; Brink, Janus; Maartens, Deneys; Browne, Keith; Strydom, Ockert; De Bruyn, David
2016-07-01
The efficient operation of a telescope requires awareness of its performance on a daily and long-term basis. This paper outlines the Fault Tracker, WebSAMMI and the Dashboard used by the Southern African Large Telescope (SALT) to achieve this aim. Faults are mostly logged automatically, but the Fault Tracker allows users to add and edit faults. The SALT Astronomer and SALT Operator record weather conditions and telescope usage with WebSAMMI. Various efficiency metrics are shown for different time periods on the Dashboard. A kiosk mode for displaying on a public screen is included. Possible applications for other telescopes are discussed.
Test and User Facilities | NREL
| L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z B Battery Thermal and Life Test Facility High-Flux Solar Furnace I Integrated Biorefinery Research Facility L Large Payload Solar Tracker M
Newborn Screening Saves Lives Reauthorization Act of 2013
Sen. Hagan, Kay R. [D-NC
2013-08-01
House - 02/07/2014 Referred to the Subcommittee on Health. (All Actions) Notes: For further action, see H.R.1281, which became Public Law 113-240 on 12/18/2014. Tracker: This bill has the status Passed SenateHere are the steps for Status of Legislation:
Ramot, Daniel; Johnson, Brandon E.; Berry, Tommie L.; Carnell, Lucinda; Goodman, Miriam B.
2008-01-01
Background Caenorhabditis elegans locomotion is a simple behavior that has been widely used to dissect genetic components of behavior, synaptic transmission, and muscle function. Many of the paradigms that have been created to study C. elegans locomotion rely on qualitative experimenter observation. Here we report the implementation of an automated tracking system developed to quantify the locomotion of multiple individual worms in parallel. Methodology/Principal Findings Our tracking system generates a consistent measurement of locomotion that allows direct comparison of results across experiments and experimenters and provides a standard method to share data between laboratories. The tracker utilizes a video camera attached to a zoom lens and a software package implemented in MATLAB®. We demonstrate several proof-of-principle applications for the tracker including measuring speed in the absence and presence of food and in the presence of serotonin. We further use the tracker to automatically quantify the time course of paralysis of worms exposed to aldicarb and levamisole and show that tracker performance compares favorably to data generated using a hand-scored metric. Conclusions/Signficance Although this is not the first automated tracking system developed to measure C. elegans locomotion, our tracking software package is freely available and provides a simple interface that includes tools for rapid data collection and analysis. By contrast with other tools, it is not dependent on a specific set of hardware. We propose that the tracker may be used for a broad range of additional worm locomotion applications including genetic and chemical screening. PMID:18493300
Coformer screening using thermal analysis based on binary phase diagrams.
Yamashita, Hiroyuki; Hirakura, Yutaka; Yuda, Masamichi; Terada, Katsuhide
2014-08-01
The advent of cocrystals has demonstrated a growing need for efficient and comprehensive coformer screening in search of better development forms, including salt forms. Here, we investigated a coformer screening system for salts and cocrystals based on binary phase diagrams using thermal analysis and examined the effectiveness of the method. Indomethacin and tenoxicam were used as models of active pharmaceutical ingredients (APIs). Physical mixtures of an API and 42 kinds of coformers were analyzed using Differential Scanning Calorimetry (DSC) and X-ray DSC. We also conducted coformer screening using a conventional slurry method and compared these results with those from the thermal analysis method and previous studies. Compared with the slurry method, the thermal analysis method was a high-performance screening system, particularly for APIs with low solubility and/or propensity to form solvates. However, this method faced hurdles for screening coformers combined with an API in the presence of kinetic hindrance for salt or cocrystal formation during heating or if there is degradation near the metastable eutectic temperature. The thermal analysis and slurry methods are considered complementary to each other for coformer screening. Feasibility of the thermal analysis method in drug discovery practice is ensured given its small scale and high throughput.
AMS Blanket and TTCS Wedge Install during EVA 32
2015-10-28
Close-up view of the Alpha Magnetic Spectrometer-02 (AMS-02), in the area where the Tracker Thermal Control System (TTCS) wedge will be installed. Image was taken by Extravehicular Crewmember 2 (EV2) during Extravehicular Activity 32 (EVA 32) and released on social media.
Risk-Based Security Screening for Members of the Armed Forces Act
Sen. Hutchison, Kay Bailey [R-TX
2011-12-07
Senate - 12/07/2011 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Notes: For further action, see H.R.1801, which became Public Law 112-86 on 1/3/2012. Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Engaging Overweight Adolescents in a Health and Fitness Program Using Wearable Activity Trackers.
Wilson, Marian; Ramsay, Samantha; Young, Kimberly J
Our objectives were to (a) examine feasibility and receptivity of overweight adolescents joining a community-based group fitness program and (b) test preliminary efficacy of a 12-week pilot intervention designed to promote health, fitness, and self-efficacy for the identified teens. The 12-week fitness program for overweight adolescents was developed and included planned physical activities, nutrition classes, and goal-setting sessions. A one-group pre-/posttest study design evaluated 20 participants from grades 10 through 12 who enrolled in the program pilot study. Participants were given a wearable activity tracker that captured data using an Internet-based platform. Outcome measures included body mass index, screen time, fitness, and cardiovascular measures. A community fitness program for overweight adolescents was successfully implemented. High school students were receptive to the intervention and reported high program satisfaction. Positive effects included measurements of strength, systolic blood pressure, weight, and screen time behaviors. This study provides evidence to support the feasibility, acceptance, and preliminary effects of the pilot program with overweight adolescents. Copyright © 2017 National Association of Pediatric Nurse Practitioners. Published by Elsevier Inc. All rights reserved.
Sen. Levin, Carl [D-MI
2011-04-14
Senate - 04/14/2011 Read twice and referred to the Committee on Homeland Security and Governmental Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Bennett, Charles L.
2007-09-18
A solar thermal powered aircraft powered by heat energy from the sun. A heat engine, such as a Stirling engine, is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller. The heat engine has a thermal battery in thermal contact with it so that heat is supplied from the thermal battery. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.
Mechatronic Prototype of Parabolic Solar Tracker.
Morón, Carlos; Díaz, Jorge Pablo; Ferrández, Daniel; Ramos, Mari Paz
2016-06-15
In the last 30 years numerous attempts have been made to improve the efficiency of the parabolic collectors in the electric power production, although most of the studies have focused on the industrial production of thermoelectric power. This research focuses on the application of this concentrating solar thermal power in the unexplored field of building construction. To that end, a mechatronic prototype of a hybrid paraboloidal and cylindrical-parabolic tracker based on the Arduido technology has been designed. The prototype is able to measure meteorological data autonomously in order to quantify the energy potential of any location. In this way, it is possible to reliably model real commercial equipment behavior before its deployment in buildings and single family houses.
Mechatronic Prototype of Parabolic Solar Tracker
Morón, Carlos; Díaz, Jorge Pablo; Ferrández, Daniel; Ramos, Mari Paz
2016-01-01
In the last 30 years numerous attempts have been made to improve the efficiency of the parabolic collectors in the electric power production, although most of the studies have focused on the industrial production of thermoelectric power. This research focuses on the application of this concentrating solar thermal power in the unexplored field of building construction. To that end, a mechatronic prototype of a hybrid paraboloidal and cylindrical-parabolic tracker based on the Arduido technology has been designed. The prototype is able to measure meteorological data autonomously in order to quantify the energy potential of any location. In this way, it is possible to reliably model real commercial equipment behavior before its deployment in buildings and single family houses. PMID:27314359
Rep. Oberstar, James L. [D-MN-8
2009-05-07
House - 05/26/2009 Referred to the Subcommittee on Transportation Security and Infrastructure Protection. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Self-pressurizing Stirling engine
Bennett, Charles L.
2010-10-12
A solar thermal powered aircraft powered by heat energy from the sun. A heat engine, such as a Stirling engine, is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller. The heat engine has a thermal battery in thermal contact with it so that heat is supplied from the thermal battery. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.
Pian, Wenjing; Khoo, Christopher SG
2017-01-01
Background Users searching for health information on the Internet may be searching for their own health issue, searching for someone else’s health issue, or browsing with no particular health issue in mind. Previous research has found that these three categories of users focus on different types of health information. However, most health information websites provide static content for all users. If the three types of user health information need contexts can be identified by the Web application, the search results or information offered to the user can be customized to increase its relevance or usefulness to the user. Objective The aim of this study was to investigate the possibility of identifying the three user health information contexts (searching for self, searching for others, or browsing with no particular health issue in mind) using just hyperlink clicking behavior; using eye-tracking information; and using a combination of eye-tracking, demographic, and urgency information. Predictive models are developed using multinomial logistic regression. Methods A total of 74 participants (39 females and 35 males) who were mainly staff and students of a university were asked to browse a health discussion forum, Healthboards.com. An eye tracker recorded their examining (eye fixation) and skimming (quick eye movement) behaviors on 2 types of screens: summary result screen displaying a list of post headers, and detailed post screen. The following three types of predictive models were developed using logistic regression analysis: model 1 used only the time spent in scanning the summary result screen and reading the detailed post screen, which can be determined from the user’s mouse clicks; model 2 used the examining and skimming durations on each screen, recorded by an eye tracker; and model 3 added user demographic and urgency information to model 2. Results An analysis of variance (ANOVA) analysis found that users’ browsing durations were significantly different for the three health information contexts (P<.001). The logistic regression model 3 was able to predict the user’s type of health information context with a 10-fold cross validation mean accuracy of 84% (62/74), followed by model 2 at 73% (54/74) and model 1 at 71% (52/78). In addition, correlation analysis found that particular browsing durations were highly correlated with users’ age, education level, and the urgency of their information need. Conclusions A user’s type of health information need context (ie, searching for self, for others, or with no health issue in mind) can be identified with reasonable accuracy using just user mouse clicks that can easily be detected by Web applications. Higher accuracy can be obtained using Google glass or future computing devices with eye tracking function. PMID:29269342
Sen. Blunt, Roy [R-MO
2013-09-23
Senate - 09/23/2013 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Rep. Neal, Richard E. [D-MA-2
2011-10-13
House - 10/19/2011 Referred for a period ending not later than October 19, 2011, (or for a later time if the Chairman so designates) to the Subcommittee on Health, in each case for consideration of such provisions as fall within the jurisdiction of the subcommittee concerned. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Sen. Manchin, Joe, III [D-WV
2014-01-16
Senate - 01/16/2014 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Rep. Space, Zachary T. [D-OH-18
2010-07-30
Senate - 09/29/2010 Received in the Senate and Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:
Remote gaze tracking system for 3D environments.
Congcong Liu; Herrup, Karl; Shi, Bertram E
2017-07-01
Eye tracking systems are typically divided into two categories: remote and mobile. Remote systems, where the eye tracker is located near the object being viewed by the subject, have the advantage of being less intrusive, but are typically used for tracking gaze points on fixed two dimensional (2D) computer screens. Mobile systems such as eye tracking glasses, where the eye tracker are attached to the subject, are more intrusive, but are better suited for cases where subjects are viewing objects in the three dimensional (3D) environment. In this paper, we describe how remote gaze tracking systems developed for 2D computer screens can be used to track gaze points in a 3D environment. The system is non-intrusive. It compensates for small head movements by the user, so that the head need not be stabilized by a chin rest or bite bar. The system maps the 3D gaze points of the user onto 2D images from a scene camera and is also located remotely from the subject. Measurement results from this system indicate that it is able to estimate gaze points in the scene camera to within one degree over a wide range of head positions.
Manin, Alex N; Voronin, Alexander P; Drozd, Ksenia V; Manin, Nikolay G; Bauer-Brandl, Annette; Perlovich, German L
2014-12-18
The main problem occurring at the early stages of cocrystal search is the choice of an effective screening technique. Among the most popular techniques of obtaining cocrystals are crystallization from solution, crystallization from melt and solvent-drop grinding. This paper represents a comparative analysis of the following screening techniques: DSC cocrystal screening method, thermal microscopy and saturation temperature method. The efficiency of different techniques of cocrystal screening was checked in 18 systems. Benzamide and benzoic acid derivatives were chosen as model systems due to their ability to form acid-amide supramolecular heterosynthon. The screening has confirmed the formation of 6 new cocrystals. The screening by the saturation temperature method has the highest screen-out rate but the smallest range of application. DSC screening has a satisfactory accuracy and allows screening over a short time. Thermal microscopy is most efficient as an additional technique used to interpret ambiguous DSC screening results. The study also included an analysis of the influence of solvent type and component solubility on cocrystal formation. Copyright © 2014 Elsevier B.V. All rights reserved.
Rep. Kinzinger, Adam [R-IL-16
2014-06-05
Senate - 06/24/2014 Received in the Senate and Read twice and referred to the Committee on Energy and Natural Resources. (All Actions) Tracker: This bill has the status Passed HouseHere are the steps for Status of Legislation:
Rankline-Brayton engine powered solar thermal aircraft
Bennett, Charles L [Livermore, CA
2012-03-13
A solar thermal powered aircraft powered by heat energy from the sun. A Rankine-Brayton hybrid cycle heat engine is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller or other mechanism for enabling sustained free flight. The Rankine-Brayton engine has a thermal battery, preferably containing a lithium-hydride and lithium mixture, operably connected to it so that heat is supplied from the thermal battery to a working fluid. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.
Rankine-Brayton engine powered solar thermal aircraft
Bennett, Charles L [Livermore, CA
2009-12-29
A solar thermal powered aircraft powered by heat energy from the sun. A Rankine-Brayton hybrid cycle heat engine is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller or other mechanism for enabling sustained free flight. The Rankine-Brayton engine has a thermal battery, preferably containing a lithium-hydride and lithium mixture, operably connected to it so that heat is supplied from the thermal battery to a working fluid. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.
NASA Astrophysics Data System (ADS)
Taruvai Kalyana Kumar, Rajeshwari; de Mello Gindri, Izabelle; Kinnamon, David; Kanchustambham, Pradyotha; Rodrigues, Danieli; Prasad, Shalini; BiomaterialsOsseointegration; Novel Engineering Lab Collaboration
2015-03-01
Characterization and analysis of rare cells provide critical cues for early diagnosis of diseases. Electrokinetic cell separation has been previously established to have greater efficiency when compared to traditional flow cytometry methods. It has been shown by many researchers that buffer solutions in which cells are suspended in, have enormous effects on producing required dielectrophoretic (DEP) forces to characterize cells. Most commonly used suspension buffers used are deionized water and cell media. However, these solutions exhibit high level of intrinsic noise, which greatly masks the electrokinetic signals from cells under study. Ionic liquids (ILs) show promise towards the creation of conductive fluids with required electrical properties. The goal of this project is to design and test ILs for enhancing DEP forces on cells while creating an environment for preserving their integrity. We analyzed two methylimidazolium based ILs as suspension medium for cell separation. These dicationic ILs possess slight electrical and structural differences with high thermal stability. The two ILs were tested for cytotoxicity using HeLa and bone cells. The effects of electrical neutrality, free charge screening due to ILs towards enhanced electrokinetic signals from cells were studied with improved system resolution and no harmful effects.
2015-03-04
lower rates of smoking cessation compared to Whites. African American smokers also live in communities that have a disproportionately high number of...Eye Tracker Screen Shots ................................................................... 139 Figure 6. Schematic Depiction of a PDA field...for African American smokers. African American smokers also live in communities that have a disproportionately high number of tobacco cues and
Sen. Murkowski, Lisa [R-AK
2014-05-21
Senate - 05/21/2014 Submitted in the Senate, considered, and agreed to without amendment and with a preamble by Unanimous Consent. (All Actions) Tracker: This bill has the status Agreed to in SenateHere are the steps for Status of Legislation:
Thermal feedback in virtual reality and telerobotic systems
NASA Technical Reports Server (NTRS)
Zerkus, Mike; Becker, Bill; Ward, Jon; Halvorsen, Lars
1994-01-01
A new concept has been developed that allows temperature to be part of the virtual world. The Displaced Temperature Sensing System (DTSS) can 'display' temperature in a virtual reality system.The DTSS can also serve as a feedback device for telerobotics. For virtual reality applications the virtual world software would be required to have a temperature map of its world. By whatever means (magnetic tracker, ultrasound tracker, etc.) the hand and fingers, which have been instrumented with thermodes, would be tracked. The temperature associated with the current position would be transmitted to the DRSS via a serial data link. The DTSS would provide that temperature to the fingers. For telerobotic operation the function of the DTSS is to transmit a temperature from a remote location to the fingers where the temperature can be felt.
NASA Astrophysics Data System (ADS)
Borges de Sousa, P.; Morrone, M.; Hovenga, N.; Garion, C.; van Weelderen, R.; Koettig, T.; Bremer, J.
2017-12-01
The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) will increase the accelerator’s luminosity by a factor 10 beyond its original design value, giving rise to more collisions and generating an intense flow of debris. A new beam screen has been designed for the inner triplets that incorporates tungsten alloy blocks to shield the superconducting magnets and the 1.9 K superfluid helium bath from incoming radiation. These screens will operate between 60 K and 80 K and are designed to sustain a nominal head load of 15 Wm-1, over 10 times the nominal heat load for the original LHC design. Their overall new and more complex design requires them and their constituent parts to be characterised from a thermal performance standpoint. In this paper we describe the experimental parametric study carried out on two principal thermal components: a representative sample of the beam screen with a tungsten-based alloy block and thermal link and the supporting structure composed of an assembly of ceramic spheres and titanium springs. Results from both studies are shown and discussed regarding their impact on the baseline considerations for the thermal design of the beam screens.
Pian, Wenjing; Khoo, Christopher Sg; Chi, Jianxing
2017-12-21
Users searching for health information on the Internet may be searching for their own health issue, searching for someone else's health issue, or browsing with no particular health issue in mind. Previous research has found that these three categories of users focus on different types of health information. However, most health information websites provide static content for all users. If the three types of user health information need contexts can be identified by the Web application, the search results or information offered to the user can be customized to increase its relevance or usefulness to the user. The aim of this study was to investigate the possibility of identifying the three user health information contexts (searching for self, searching for others, or browsing with no particular health issue in mind) using just hyperlink clicking behavior; using eye-tracking information; and using a combination of eye-tracking, demographic, and urgency information. Predictive models are developed using multinomial logistic regression. A total of 74 participants (39 females and 35 males) who were mainly staff and students of a university were asked to browse a health discussion forum, Healthboards.com. An eye tracker recorded their examining (eye fixation) and skimming (quick eye movement) behaviors on 2 types of screens: summary result screen displaying a list of post headers, and detailed post screen. The following three types of predictive models were developed using logistic regression analysis: model 1 used only the time spent in scanning the summary result screen and reading the detailed post screen, which can be determined from the user's mouse clicks; model 2 used the examining and skimming durations on each screen, recorded by an eye tracker; and model 3 added user demographic and urgency information to model 2. An analysis of variance (ANOVA) analysis found that users' browsing durations were significantly different for the three health information contexts (P<.001). The logistic regression model 3 was able to predict the user's type of health information context with a 10-fold cross validation mean accuracy of 84% (62/74), followed by model 2 at 73% (54/74) and model 1 at 71% (52/78). In addition, correlation analysis found that particular browsing durations were highly correlated with users' age, education level, and the urgency of their information need. A user's type of health information need context (ie, searching for self, for others, or with no health issue in mind) can be identified with reasonable accuracy using just user mouse clicks that can easily be detected by Web applications. Higher accuracy can be obtained using Google glass or future computing devices with eye tracking function. ©Wenjing Pian, Christopher SG Khoo, Jianxing Chi. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 21.12.2017.
NASA Astrophysics Data System (ADS)
Realmuto, Vincent J.; Berk, Alexander
2016-11-01
We describe the development of Plume Tracker, an interactive toolkit for the analysis of multispectral thermal infrared observations of volcanic plumes and clouds. Plume Tracker is the successor to MAP_SO2, and together these flexible and comprehensive tools have enabled investigators to map sulfur dioxide (SO2) emissions from a number of volcanoes with TIR data from a variety of airborne and satellite instruments. Our objective for the development of Plume Tracker was to improve the computational performance of the retrieval procedures while retaining the accuracy of the retrievals. We have achieved a 300 × improvement in the benchmark performance of the retrieval procedures through the introduction of innovative data binning and signal reconstruction strategies, and improved the accuracy of the retrievals with a new method for evaluating the misfit between model and observed radiance spectra. We evaluated the accuracy of Plume Tracker retrievals with case studies based on MODIS and AIRS data acquired over Sarychev Peak Volcano, and ASTER data acquired over Kilauea and Turrialba Volcanoes. In the Sarychev Peak study, the AIRS-based estimate of total SO2 mass was 40% lower than the MODIS-based estimate. This result was consistent with a 45% reduction in the AIRS-based estimate of plume area relative to the corresponding MODIS-based estimate. In addition, we found that our AIRS-based estimate agreed with an independent estimate, based on a competing retrieval technique, within a margin of ± 20%. In the Kilauea study, the ASTER-based concentration estimates from 21 May 2012 were within ± 50% of concurrent ground-level concentration measurements. In the Turrialba study, the ASTER-based concentration estimates on 21 January 2012 were in exact agreement with SO2 concentrations measured at plume altitude on 1 February 2012.
Sensing Technologies for Autism Spectrum Disorder Screening and Intervention
Cabibihan, John-John; Javed, Hifza; Aldosari, Mohammed; Frazier, Thomas W.; Elbashir, Haitham
2016-01-01
This paper reviews the state-of-the-art in sensing technologies that are relevant for Autism Spectrum Disorder (ASD) screening and therapy. This disorder is characterized by difficulties in social communication, social interactions, and repetitive behaviors. It is diagnosed during the first three years of life. Early and intensive interventions have been shown to improve the developmental trajectory of the affected children. The earlier the diagnosis, the sooner the intervention therapy can begin, thus, making early diagnosis an important research goal. Technological innovations have tremendous potential to assist with early diagnosis and improve intervention programs. The need for careful and methodological evaluation of such emerging technologies becomes important in order to assist not only the therapists and clinicians in their selection of suitable tools, but to also guide the developers of the technologies in improving hardware and software. In this paper, we survey the literatures on sensing technologies for ASD and we categorize them into eye trackers, movement trackers, electrodermal activity monitors, tactile sensors, vocal prosody and speech detectors, and sleep quality assessment devices. We assess their effectiveness and study their limitations. We also examine the challenges faced by this growing field that need to be addressed before these technologies can perform up to their theoretical potential. PMID:28036004
Thermal design of the Mu2e detector solenoid
Dhanaraj, N.; Wands, R.; Buehler, M.; ...
2014-12-18
The reference design for a superconducting detector solenoid (DS) for the Mu2e experiment has been completed. In this study, the main functions of the DS are to provide a graded field in the region of the stopping target, which ranges from 2 to 1 T and a uniform precision magnetic field of 1 T in a volume large enough to house a tracker downstream of the stopping target. The inner diameter of the magnet cryostat is 1.9 m and the length is 10.9 m. The gradient section of the magnet is about 4 m long and the spectrometer section withmore » a uniform magnetic field is about 6 m long. The inner cryostat wall supports the stopping target, tracker, calorimeter and other equipment installed in the DS. This warm bore volume is under vacuum during operation. It is sealed on one end by the muon beam stop, while it is open on the other end where it interfaces with the Transport Solenoid. The operating temperature of the magnetic coil is 4.7 K and is indirectly cooled with helium flowing in a thermosiphon cooling scheme. This paper describes the thermal design of the solenoid, including the design aspects of the thermosiphon for the coil cooling, forced flow cooling of the thermal shields with 2 phase LN2 (Liquid Nitrogen) and the transient studies of the cool down of the cold mass as well.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandoval, D. M.; Strittmatter, R. B.; Abeyta, J. D.
2004-01-01
The initial objectives of this effort were to provide a hardware and software platform that can address the requirements for the accountability of classified removable electronic media and vault access logging. The Media Tracker system software assists classified media custodian in managing vault access logging and Media Tracking to prevent the inadvertent violation of rules or policies for the access to a restricted area and the movement and use of tracked items. The MediaTracker system includes the software tools to track and account for high consequence security assets and high value items. The overall benefits include: (1) real-time access tomore » the disposition of all Classified Removable Electronic Media (CREM), (2) streamlined security procedures and requirements, (3) removal of ambiguity and managerial inconsistencies, (4) prevention of incidents that can and should be prevented, (5) alignment with the DOE's initiative to achieve improvements in security and facility operations through technology deployment, and (6) enhanced individual responsibility by providing a consistent method of dealing with daily responsibilities. In response to initiatives to enhance the control of classified removable electronic media (CREM), the Media Tracker software suite was developed, piloted and implemented at the Los Alamos National Laboratory beginning in July 2000. The Media Tracker software suite assists in the accountability and tracking of CREM and other high-value assets. One component of the MediaTracker software suite provides a Laboratory-approved media tracking system. Using commercial touch screen and bar code technology, the MediaTracker (MT) component of the MediaTracker software suite provides an efficient and effective means to meet current Laboratory requirements and provides new-engineered controls to help assure compliance with those requirements. It also establishes a computer infrastructure at vault entrances for vault access logging, and can accommodate several methods of positive identification including smart cards and biometrics. Currently, we have three mechanisms that provide added security for accountability and tracking purposes. One mechanism consists of a portable, hand-held inventory scanner, which allows the custodian to physically track the items that are not accessible within a particular area. The second mechanism is a radio frequency identification (RFID) consisting of a monitoring portal, which tracks and logs in a database all activity tagged of items that pass through the portals. The third mechanism consists of an electronic tagging of a flash memory device for automated inventory of CREM in storage. By modifying this USB device the user is provided with added assurance, limiting the data from being obtained from any other computer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Xue; Liu, Yueqiang; Gao, Zhe
Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) at slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. Furthermore, this physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, resultedmore » from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. These modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.« less
Bai, Xue; Liu, Yueqiang; Gao, Zhe
2017-09-21
Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) at slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. Furthermore, this physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, resultedmore » from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. These modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.« less
NASA Astrophysics Data System (ADS)
Bai, Xue; Liu, Yueqiang; Gao, Zhe
2017-10-01
Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) in a slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. This physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, which resulted from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement, and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. Modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.
Preparation and properties of the multi-layer aerogel thermal insulation composites
NASA Astrophysics Data System (ADS)
Wang, Miao; Feng, Junzong; Jiang, Yonggang; Zhang, Zhongming; Feng, Jian
2018-03-01
Multi-layer insulation materials possess low radiation thermal conductivity, and excellent thermal insulation property in a vacuum environment. However, the spacers of the traditional multi-layer insulation materials are mostly loose fibers, which lead to more sensitive to the vacuum environmental of serviced. With the vacuum degree declining, gas phases thermal convection increase obviously, and the reflective screen will be severe oxidation, all of these make the thermal insulation property of traditional multi-layer insulation deteriorate, thus limits its application scope. In this paper, traditional multi-layer insulation material is combined with aerogel and obtain a new multi-layer aerogel thermal insulation composite, and the effects of the number, thickness and type of the reflective screens on the thermal insulation properties of the multi-layer composites are also studied. The result is that the thermal insulation property of the new type multi-layer aerogel composites is better than the pure aerogel composites and the traditional multi-layer insulation composites. When the 0.01 mm stainless steel foil as the reflective screen, and the aluminum silicate fiber and silica aerogel as the spacer layer, the layer density of composite with the best thermal insulation property is one layer per millimeter at 1000 °C.
Shock Initiation of Thermally Expanded TATB
NASA Astrophysics Data System (ADS)
Mulford, Roberta; Swift, Damian
2011-06-01
The plastic-bonded explosive PBX-9502 undergoes unusual hysteretic thermal expansion, or ``ratchet growth'' as a consequence of the uniaxial thermal expansion of the graphitic structure of the major component, TATB explosive. Upon thermal cycling, the density of the material can be reduced by as much as 9%, resulting in a distinct increase in the shock sensitivity of the solid. Run distances to detonation have been measured in thermally expanded samples of PBX-9502, using embedded particle velocity gauges and shock tracker gauges. Uniaxial shocks were generated using a light gas gun, to provide a repeatable stimulus for initiation of detonation. We have applied a porosity model to adjust standard Pop plot data to the reduced density of our samples, to investigate whether the sensitivity of the PBX 9502 increases ideally with the decreasing density, or whether the microscopically non-uniform expansion that occurs during ``ratchet growth'' leads to abnormal sensitivity, possibly as a result of cracking or debonding from the binder, as observed in micrographs of the sample.
Learning Collaborative Sparse Representation for Grayscale-Thermal Tracking.
Li, Chenglong; Cheng, Hui; Hu, Shiyi; Liu, Xiaobai; Tang, Jin; Lin, Liang
2016-09-27
Integrating multiple different yet complementary feature representations has been proved to be an effective way for boosting tracking performance. This paper investigates how to perform robust object tracking in challenging scenarios by adaptively incorporating information from grayscale and thermal videos, and proposes a novel collaborative algorithm for online tracking. In particular, an adaptive fusion scheme is proposed based on collaborative sparse representation in Bayesian filtering framework. We jointly optimize sparse codes and the reliable weights of different modalities in an online way. In addition, this work contributes a comprehensive video benchmark, which includes 50 grayscale-thermal sequences and their ground truth annotations for tracking purpose. The videos are with high diversity and the annotations were finished by one single person to guarantee consistency. Extensive experiments against other stateof- the-art trackers with both grayscale and grayscale-thermal inputs demonstrate the effectiveness of the proposed tracking approach. Through analyzing quantitative results, we also provide basic insights and potential future research directions in grayscale-thermal tracking.
INITIAL SCREENING OF THERMAL DESORPTION FOR SOIL REMEDIATION
The purpose of the paper is to present procedures for collecting and evaluating key data that affect the potential application of thermal desorption for a specific site. These data are defined as 'criticalsuccess factors'. The screening prodcedure can be used to peerform an ini...
NASA Astrophysics Data System (ADS)
Realmuto, V. J.; Baxter, S.; Webley, P. W.
2011-12-01
Plume Tracker is the next generation of interactive plume mapping tools pioneered by MAP_SO2. First developed in 1995, MAP_SO2 has been used to study plumes at a number of volcanoes worldwide with data acquired by both airborne and space-borne instruments. The foundation of these tools is a radiative transfer (RT) model, based on MODTRAN, which we use as the forward model for our estimation of ground temperature and sulfur dioxide concentration. Plume Tracker retains the main functions of MAP_SO2, providing interactive tools to input radiance measurements and ancillary data, such as profiles of atmospheric temperature and humidity, to the retrieval procedure, generating the retrievals, and visualizing the resulting retrievals. Plume Tracker improves upon MAP_SO2 in the following areas: (1) an RT model based on an updated version of MODTRAN, (2) a retrieval procedure based on maximizing the vector projection of model spectra onto observed spectra, rather than minimizing the least-squares misfit between the model and observed spectra, (3) an ability to input ozone profiles to the RT model, (4) increased control over the vertical distribution of the atmospheric gas species used in the model, (5) a standard programmatic interface to the RT model code, based on the Component Object Model (COM) interface, which will provide access to any programming language that conforms to the COM standard, and (6) a new binning algorithm that decreases running time by exploiting spatial redundancy in the radiance data. Based on our initial testing, the binning algorithm can reduce running time by an order of magnitude. The Plume Tracker project is a collaborative effort between the Jet Propulsion Laboratory and Geophysical Institute (GI) of the University of Alaska-Fairbanks. Plume Tracker is integrated into the GI's operational plume dispersion modeling system and will ingest temperature and humidity profiles generated by the Weather Research and Forecasting model, together with plume height estimates from the Puff model. The access to timely forecasts of atmospheric conditions, together with the reductions in running time, will increase the utility of Plume Tracker in the Alaska Volcano Observatory's mission to mitigate volcanic hazards in Alaska and the Northern Pacific region.
2009-09-30
NRL Code 8221) is the Lead Thermal Engineer for heater and blanket design for the mission. WORK COMPLETED The program developed a briefing...development of such science-enabling technology is critical for space-flight mission on small spacecraft , such as CubeSats, that cannot afford the mass, power...critical for space-flight mission on small spacecraft , such as CubeSats, that cannot afford the mass, power or cost of traditional star trackers but
NASA Astrophysics Data System (ADS)
Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.
2016-05-01
The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.
Reverberatory screen for a radiant burner
Gray, Paul E.
1999-01-01
The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.
A stellar tracking reference system
NASA Technical Reports Server (NTRS)
Klestadt, B.
1971-01-01
A stellar attitude reference system concept for satellites was studied which promises to permit continuous precision pointing of payloads with accuracies of 0.001 degree without the use of gyroscopes. It is accomplished with the use of a single, clustered star tracker assembly mounted on a non-orthogonal, two gimbal mechanism, driven so as to unwind satellite orbital and orbit precession rates. A set of eight stars was found which assures the presence of an adequate inertial reference on a continuous basis in an arbitrary orbit. Acquisition and operational considerations were investigated and inherent reference redundancy/reliability was established. Preliminary designs for the gimbal mechanism, its servo drive, and the star tracker cluster with its associated signal processing were developed for a baseline sun-synchronous, noon-midnight orbit. The functions required of the onboard computer were determined and the equations to be solved were found. In addition detailed error analyses were carried out, based on structural, thermal and other operational considerations.
Hobby-Eberly Telescope: commissioning experience and observing plans
NASA Astrophysics Data System (ADS)
Glaspey, John W.; Adams, M. T.; Booth, John A.; Cornell, Mark E.; Fowler, James R.; Krabbendam, Victor L.; Ramsey, Lawrence W.; Ray, Frank B.; Ricklefs, Randall L.; Spiesman, W. J.
1998-07-01
Experience in bringing into operation the 91-segment primary mirror alignment and control system, the focal plane tracker system, and other critical subsystems of the HET will be described. Particular attention is given to the tracker, which utilizes three linear and three rotational degrees of freedom to follow sidereal targets. Coarse time-dependent functions for each axis are downloaded to autonomous PMAC controllers that provide the precise motion drives to the two linear stages and the hexapod system. Experience gained in aligning the sperate mirrors and then maintaining image quality in a variable thermal environments will also be described. Because of the fixed elevation of the primary optical axis, only a limited amount of time is available for observing objects in the 12 degrees wide observing band. With a small core HET team working with McDonald Observatory staff, efficient, reliable, uncomplicated methodologies are required in all aspects of the observing operations.
Neural stem cells for disease modeling of Wolman disease and evaluation of therapeutics.
Aguisanda, Francis; Yeh, Charles D; Chen, Catherine Z; Li, Rong; Beers, Jeanette; Zou, Jizhong; Thorne, Natasha; Zheng, Wei
2017-06-28
Wolman disease (WD) is a rare lysosomal storage disorder that is caused by mutations in the LIPA gene encoding lysosomal acid lipase (LAL). Deficiency in LAL function causes accumulation of cholesteryl esters and triglycerides in lysosomes. Fatality usually occurs within the first year of life. While an enzyme replacement therapy has recently become available, there is currently no small-molecule drug treatment for WD. We have generated induced pluripotent stem cells (iPSCs) from two WD patient dermal fibroblast lines and subsequently differentiated them into neural stem cells (NSCs). The WD NSCs exhibited the hallmark disease phenotypes of neutral lipid accumulation, severely deficient LAL activity, and increased LysoTracker dye staining. Enzyme replacement treatment dramatically reduced the WD phenotype in these cells. In addition, δ-tocopherol (DT) and hydroxypropyl-beta-cyclodextrin (HPBCD) significantly reduced lysosomal size in WD NSCs, and an enhanced effect was observed in DT/HPBCD combination therapy. The results demonstrate that these WD NSCs are valid cell-based disease models with characteristic disease phenotypes that can be used to evaluate drug efficacy and screen compounds. DT and HPBCD both reduce LysoTracker dye staining in WD cells. The cells may be used to further dissect the pathology of WD, evaluate compound efficacy, and serve as a platform for high-throughput drug screening to identify new compounds for therapeutic development.
Mitigating Thermal Runaway Risk in Lithium Ion Batteries
NASA Technical Reports Server (NTRS)
Darcy, Eric; Jeevarajan, Judy; Russell, Samuel
2014-01-01
The JSC/NESC team has successfully demonstrated Thermal Runaway (TR) risk reduction in a lithium ion battery for human space flight by developing and implementing verifiable design features which interrupt energy transfer between adjacent electrochemical cells. Conventional lithium ion (li-Ion) batteries can fail catastrophically as a result of a single cell going into thermal runaway. Thermal runaway results when an internal component fails to separate electrode materials leading to localized heating and complete combustion of the lithium ion cell. Previously, the greatest control to minimize the probability of cell failure was individual cell screening. Combining thermal runaway propagation mitigation design features with a comprehensive screening program reduces both the probability, and the severity, of a single cell failure.
Thermal preference predicts animal personality in Nile tilapia Oreochromis niloticus.
Cerqueira, Marco; Rey, Sonia; Silva, Tome; Featherstone, Zoe; Crumlish, Margaret; MacKenzie, Simon
2016-09-01
Environmental temperature gradients provide habitat structure in which fish orientate and individual thermal choice may reflect an essential integrated response to the environment. The use of subtle thermal gradients likely impacts upon specific physiological and behavioural processes reflected as a suite of traits described by animal personality. In this study, we examine the relationship between thermal choice, animal personality and the impact of infection upon this interaction. We predicted that thermal choice in Nile tilapia Oreochromis niloticus reflects distinct personality traits and that under a challenge individuals exhibit differential thermal distribution. Nile tilapia were screened following two different protocols: 1) a suite of individual behavioural tests to screen for personality and 2) thermal choice in a custom-built tank with a thermal gradient (TCH tank) ranging from 21 to 33 °C. A first set of fish were screened for behaviour and then thermal preference, and a second set were tested in the opposite fashion: thermal then behaviour. The final thermal distribution of the fish after 48 h was assessed reflecting final thermal preferendum. Additionally, fish were then challenged using a bacterial Streptococcus iniae model infection to assess the behavioural fever response of proactive and reactive fish. Results showed that individuals with preference for higher temperatures were also classified as proactive with behavioural tests and reactive contemporaries chose significantly lower water temperatures. All groups exhibited behavioural fever recovering personality-specific thermal preferences after 5 days. Our results show that thermal preference can be used as a proxy to assess personality traits in Nile tilapia and it is a central factor to understand the adaptive meaning of animal personality within a population. Importantly, response to infection by expressing behavioural fever overrides personality-related thermal choice. © 2016 The Authors. Journal of Animal Ecology © 2016 British Ecological Society.
Rapid screening of pharmaceutical drugs using thermal desorption - SALDI mass spectrometry
NASA Astrophysics Data System (ADS)
Grechnikov, A. A.; Kubasov, A. E.; Georgieva, V. B.; Borodkov, A. S.; Nikiforov, S. M.; Simanovsky, Ya O.; Alimpiev, S. S.
2012-12-01
A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.
Fuzzy System-Based Target Selection for a NIR Camera-Based Gaze Tracker
Naqvi, Rizwan Ali; Arsalan, Muhammad; Park, Kang Ryoung
2017-01-01
Gaze-based interaction (GBI) techniques have been a popular subject of research in the last few decades. Among other applications, GBI can be used by persons with disabilities to perform everyday tasks, as a game interface, and can play a pivotal role in the human computer interface (HCI) field. While gaze tracking systems have shown high accuracy in GBI, detecting a user’s gaze for target selection is a challenging problem that needs to be considered while using a gaze detection system. Past research has used the blinking of the eyes for this purpose as well as dwell time-based methods, but these techniques are either inconvenient for the user or requires a long time for target selection. Therefore, in this paper, we propose a method for fuzzy system-based target selection for near-infrared (NIR) camera-based gaze trackers. The results of experiments performed in addition to tests of the usability and on-screen keyboard use of the proposed method show that it is better than previous methods. PMID:28420114
A feasible thermal-cycle screening system for cryogenic semiconductor components
NASA Astrophysics Data System (ADS)
Wu, Ligang; Liu, Dafu; Huang, Yimin; Zhu, Sangen; Gong, Haimei
2005-01-01
For the limit of its lifetime, the Stirling cooler is operated on the intermittent mode in satellite in some cases. Thus such cryogenic semiconductor components as HgCdTe mid or long wavelength infrared (IR) detectors are subjected to thousands of repeated thermal cycles from below -173°C to room temperature. Therefore, a series of experiments focused on quality, performance and reliability are essential in order to satisfy the reasonable requirements. Accordingly, a feasible thermal cycle screening system is put forward. And a vast experimental data show that thermal cycle tests play the most effective role in the environment stress screen (ESS). In this paper, we introduce the system to help to study the main failure mechanisms and improve the performance of the semiconductor components. Such main failure mechanisms as solder-ball invalidation encountered commonly in the detector modules, which is due to the large thermal expansion coefficient mismatch among different materials. The thermal cycle system is based on the principle of heat exchange. We expect HgCdTe IR detectors be cooled to lower than -173°C and heated to room temperature in a few minutes. Above all, we simulate the heating and cooling system through finite element method (FEM). As a result, the computations reveal that the IR detectors can be heated and cooled at a higher rate than expected. A consequent design of the entire system is founded on the simulation. At last, we adjust the mechanical structure of heat exchange system to the adaptive state to accomplish the ESS. The thermal cycle screening system includes an autocontrol part and a test part. The autocontrol part is adopted to realize the heat exchange between IR detectors and the environment, and the test one to inspect the temperature and electrical parameters of these detectors. And at least four IR detector samples can be screened at one time.
NIR tracking assists sports medicine in junior basketball training
NASA Astrophysics Data System (ADS)
Paeglis, Roberts; Bluss, Kristaps; Rudzitis, Andris; Spunde, Andris; Brice, Tamara; Nitiss, Edgars
2011-07-01
We recorded eye movements of eight elite junior basketball players. We hypothesized that a more stable gaze is correlated to a better shot rate. Upon preliminary testing we invited male juniors whose eyes could be reliably tracked in a game situation. To these ends, we used a head-mounted video-based eye tracker. The participants had no record of ocular or other health issues. No significant differences were found between shots made with and without the tracker cap, Paired samples t-test yielded p= .130 for the far and p=..900 > .050 for the middle range shots. The players made 40 shots from common far and middle range locations, 5 and 4 meters respectively for aged 14 years As expected, a statistical correlation was found between gaze fixation (in milliseconds) for the far and middle range shot rates, r=.782, p=.03. Notably, juniors who fixated longer before a shot had a more stable fixation or a lower gaze dispersion (in tracker's screen pixels), r=-.786, p=.02. This finding was augmented by the observation that the gaze dispersion while aiming at the basket was less (i.e., gaze more stable) in those who were more likely to score. We derived a regression equation linking fixation duration to shot success. We advocate infra-red eye tracking as a means to monitor player selection and training success.
Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain
2015-12-01
Display (LCD) Screen Thermal Testing to Simulate Solar Gain 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6 . AUTHOR(S) Steven...Sunlight, Monitor Screen Covered 9 2.6 Test 6 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass 9 2.7 Test 7 – Bench Test with a 250 W Heat...that was used. The use of a black background with white text was important in creating the worst-case scenario for the absorption of solar radiation
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2017-01-01
AZ-2000-IECW white paint and StaMet black Kapton have been evaluated for the Kevlar/polyimide shells that enclose the Solar Probe Plus Magnetometer (MAG) sensors and multilayer insulation. Flight qualification testing on AZ-2000-IECW painted Kevlar/polyimide laminate was completed at Goddard Space Flight Center. This paint potentially meets all the requirements. However, it has no flight heritage. StaMet is hotter in the sun, and is specular. The results of the MAG thermal balance test show StaMet meets the thermal requirement and heater power budget. The mission prefers to fly StaMet after evaluating the risks of AZ-2000-IECW flaking and glint from StaMet to the Star Trackers.
Wolpin, Seth; Halpenny, Barbara; Sorrentino, Erica; Stewart, Mark; McReynolds, Justin; Cvitkovic, Ivan; Chang, Peter; Berry, Donna
2016-07-01
Shared treatment decision making in a cancer setting requires a patient's understanding of the potential benefits and risks of each treatment option. Graphical display of risk information is one approach to improving understanding. Little is known about how patients engage with infographics in the context of health education materials and whether interactions vary with health literacy levels. We conducted an observational study, using an eye tracker device, of how men with newly diagnosed localized prostate cancer visually engaged with an on-screen infographic depicting risk information in the Personal Patient Profile-Prostate. Health literacy was measured with the Short Assessment of Health Literacy-English. Gaze patterns on an exemplar screens containing infographics about survival were analyzed and explored with respect to sociodemographic and health literacy data. Acceptability of Personal Patient Profile-Prostate was measured with the Acceptability E-scale. Twenty-six English-speaking men participated, and eye tracking data were collected for 12 men on the exemplar page of risk information that we analyzed. We found preliminary evidence of visual scanning and of participants with lower literacy focusing sooner on infographics versus text. Acceptability for Personal Patient Profile-Prostate was high. These findings suggest that infographics may be of higher relative value to participants with low health literacy. Eye trackers may provide valuable information on how people visually engage with infographics and may inform development of health education materials, although care must be taken to minimize data loss.
Bulk viscous corrections to screening and damping in QCD at high temperatures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Qianqian; Dumitru, Adrian; Guo, Yun
2017-01-01
Non-equilibrium corrections to the distribution functions of quarks and gluons in a hot and dense QCD medium modify the \\hard thermal loops" (HTL). The HTLs determine the retarded, advanced, and symmetric (time-ordered) propagators for gluons with soft momenta as well as the Debye screening and Landau damping mass scales. Here, we compute such corrections to a thermal as well as to a non-thermal fixed point. The screening and damping mass scales are sensitive to the bulk pressure and hence to (pseudo-) critical dynamical scaling of the bulk viscosity in the vicinity of a second-order critical point. This could be reectedmore » in the properties of quarkonium bound states in the deconfined phase and in the dynamics of soft gluon fields.« less
Sun, Guanghao; Nakayama, Yosuke; Dagdanpurev, Sumiyakhand; Abe, Shigeto; Nishimura, Hidekazu; Kirimoto, Tetsuo; Matsui, Takemi
2017-02-01
Infrared thermography (IRT) is used to screen febrile passengers at international airports, but it suffers from low sensitivity. This study explored the application of a combined visible and thermal image processing approach that uses a CMOS camera equipped with IRT to remotely sense multiple vital signs and screen patients with suspected infectious diseases. An IRT system that produced visible and thermal images was used for image acquisition. The subjects' respiration rates were measured by monitoring temperature changes around the nasal areas on thermal images; facial skin temperatures were measured simultaneously. Facial blood circulation causes tiny color changes in visible facial images that enable the determination of the heart rate. A logistic regression discriminant function predicted the likelihood of infection within 10s, based on the measured vital signs. Sixteen patients with an influenza-like illness and 22 control subjects participated in a clinical test at a clinic in Fukushima, Japan. The vital-sign-based IRT screening system had a sensitivity of 87.5% and a negative predictive value of 91.7%; these values are higher than those of conventional fever-based screening approaches. Multiple vital-sign-based screening efficiently detected patients with suspected infectious diseases. It offers a promising alternative to conventional fever-based screening. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Robert; Goudey, Howdy; Curcija, D. Charlie
Virtually every home in the US has some form of shades, blinds, drapes, or other window attachment, but few have been designed for energy savings. In order to provide a common basis of comparison for thermal performance it is important to have validated simulation tools. This study outlines a review and validation of the ISO 15099 centre-of-glass thermal transmittance correlations for naturally ventilated cavities through measurement and detailed simulations. The focus is on the impacts of room-side ventilated cavities, such as those found with solar screens and horizontal louvred blinds. The thermal transmittance of these systems is measured experimentally, simulatedmore » using computational fluid dynamics analysis, and simulated utilizing simplified correlations from ISO 15099. Finally, correlation coefficients are proposed for the ISO 15099 algorithm that reduces the mean error between measured and simulated heat flux for typical solar screens from 16% to 3.5% and from 13% to 1% for horizontal blinds.« less
Hart, Robert; Goudey, Howdy; Curcija, D. Charlie
2017-05-16
Virtually every home in the US has some form of shades, blinds, drapes, or other window attachment, but few have been designed for energy savings. In order to provide a common basis of comparison for thermal performance it is important to have validated simulation tools. This study outlines a review and validation of the ISO 15099 centre-of-glass thermal transmittance correlations for naturally ventilated cavities through measurement and detailed simulations. The focus is on the impacts of room-side ventilated cavities, such as those found with solar screens and horizontal louvred blinds. The thermal transmittance of these systems is measured experimentally, simulatedmore » using computational fluid dynamics analysis, and simulated utilizing simplified correlations from ISO 15099. Finally, correlation coefficients are proposed for the ISO 15099 algorithm that reduces the mean error between measured and simulated heat flux for typical solar screens from 16% to 3.5% and from 13% to 1% for horizontal blinds.« less
Intelligent screening of electrofusion-polyethylene joints based on a thermal NDT method
NASA Astrophysics Data System (ADS)
Doaei, Marjan; Tavallali, M. Sadegh
2018-05-01
The combinations of infrared thermal images and artificial intelligence methods have opened new avenues for pushing the boundaries of available testing methods. Hence, in the current study, a novel thermal non-destructive testing method for polyethylene electrofusion joints was combined with k-means clustering algorithms as an intelligent screening tool. The experiments focused on ovality of pipes in the coupler, as well as misalignment of pipes-couplers in 25 mm diameter joints. The temperature responses of each joint to an internal heat pulse were recorded by an IR thermal camera, and further processed to identify the faulty joints. The results represented clustering accuracy of 92%, as well as more than 90% abnormality detection capabilities.
Front-end electronics for the Muon Portal project
NASA Astrophysics Data System (ADS)
Garozzo, S.; Marano, D.; Bonanno, G.; Grillo, A.; Romeo, G.; Timpanaro, M. C.; Lo Presti, D.; Riggi, F.; Russo, V.; Bonanno, D.; La Rocca, P.; Longhitano, F.; Bongiovanni, D. G.; Fallica, G.; Valvo, G.
2016-10-01
The Muon Portal Project was born as a joint initiative between Italian research and industrial partners, aimed at the construction of a real-size working detector prototype to inspect the content of traveling containers by means of secondary cosmic-ray muon radiation and recognize potentially dangerous hidden materials. The tomographic image is obtained by reconstructing the incoming and outgoing muon trajectories when crossing the inspected volume, employing two tracker planes located above and below the container under inspection. In this paper, the design and development of the front-end electronics of the Muon Portal detector is presented, with particular emphasis being devoted to the photo-sensor devices detecting the scintillation light and to the read-out circuitry which is in charge of processing and digitizing the analog pulse signals. In addition, the remote control system, mechanical housing, and thermal cooling system of all structural blocks of the Muon Portal tracker are also discussed, demonstrating the effectiveness and functionality of the adopted design.
Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System
NASA Technical Reports Server (NTRS)
Hastings, L. J.; Bolshinskiy, L. G.; Schunk, R. G.; Martin, A. K.; Eskridge, R. H.; Frenkel, A.; Grayson, G.; Pendleton, M. L.
2011-01-01
Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.
1954-03-01
spectral breakdown is obtained by mounting re- ceiving discs in back of Corning Glass Filters No. 3-69, 2-58, 7-56, and 0-52. The filters transmit...used for measuring the thermal flux under the smoke screen and in making the spectral measurements on radiant energy received under the smoke screen... Spectral Distribution Instrumentation a a a a a a a a a a a 30 2.4.1 Passive Receivers. . . . a a a a a . 30 2 .4 .2 Field Calorimeter * a a a a a a • a a
NASA Technical Reports Server (NTRS)
Koontz, S. L.; Albyn, K.; Leger, L.
1990-01-01
The use of thermal atom test methods as a materials selection and screening technique for low-earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined in thermal atom environments are compared with those observed in LEO and in high-quality LEO simulations. Reaction efficiencies (cu cm/atom) measured in a new type of thermal atom apparatus are one-thousandth to one ten-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of eight in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain speciic thermal atom test environments can be used as reliable materials screening tools.
McClure, Sean M; Ahl, Patrick L; Blue, Jeffrey T
2018-03-05
The purpose was to evaluate DSF for high throughput screening of protein thermal stability (unfolding/ aggregation) across a wide range of formulations. Particular focus was exploring PROTEOSTAT® - a commercially available fluorescent rotor dye - for detection of aggregation in surfactant containing formulations. Commonly used hydrophobic dyes (e.g. SYPRO™ Orange) interact with surfactants, complicating DSF measurements. CRM197 formulations were prepared and analyzed in standard 96-well plate rT-PCR system, using SYPRO™ Orange and PROTEOSTAT® dyes. Orthogonal techniques (DLS and IPF) are employed to confirm unfolding/aggregation in selected formulations. Selected formulations are subjected to non-thermal stresses (stirring and shaking) in plate based format to characterize aggregation with PROTEOSTAT®. Agreement is observed between SYPRO™ Orange (unfolding) and PROTEOSTAT® (aggregation) DSF melt temperatures across wide range of non-surfactant formulations. PROTEOSTAT® can clearly detect temperature induced aggregation in low concentration (0.2 mg/mL) CRM197 formulations containing surfactant. PROTEOSTAT® can be used to explore aggregation due to non-thermal stresses in plate based format amenable to high throughput screening. DSF measurements with complementary extrinsic dyes (PROTEOSTAT®, SYPRO™ Orange) are suitable for high throughput screening of antigen thermal stability, across a wide range of relevant formulation conditions - including surfactants -with standard, plate based rT-PCR instrumentation.
Thermal precipitation fluorescence assay for protein stability screening.
Fan, Junping; Huang, Bo; Wang, Xianping; Zhang, Xuejun C
2011-09-01
A simple and reliable method of protein stability assessment is desirable for high throughput expression screening of recombinant proteins. Here we described an assay termed thermal precipitation fluorescence (TPF) which can be used to compare thermal stabilities of recombinant protein samples directly from cell lysate supernatants. In this assay, target membrane proteins are expressed as recombinant fusions with a green fluorescence protein tag and solubilized with detergent, and the fluorescence signals are used to report the quantity of the fusion proteins in the soluble fraction of the cell lysate. After applying a heat shock, insoluble protein aggregates are removed by centrifugation. Subsequently, the amount of remaining protein in the supernatant is quantified by in-gel fluorescence analysis and compared to samples without a heat shock treatment. Over 60 recombinant membrane proteins from Escherichia coli were subject to this screening in the presence and absence of a few commonly used detergents, and the results were analyzed. Because no sophisticated protein purification is required, this TPF technique is suitable to high throughput expression screening of recombinant membrane proteins as well as soluble ones and can be used to prioritize target proteins based on their thermal stabilities for subsequent large scale expression and structural studies. Copyright © 2011 Elsevier Inc. All rights reserved.
Evaluation of an eye-pointer interaction device for human-computer interaction.
Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián
2018-03-01
Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.
Gold, Jeffrey Allen; Stephenson, Laurel E; Gorsuch, Adriel; Parthasarathy, Keshav; Mohan, Vishnu
2016-09-01
Numerous reports describe unintended consequences of electronic health record implementation. Having previously described physicians' failures to recognize patient safety issues within our electronic health record simulation environment, we now report on our use of eye and screen-tracking technology to understand factors associated with poor error recognition during an intensive care unit-based electronic health record simulation. We linked performance on the simulation to standard eye and screen-tracking readouts including number of fixations, saccades, mouse clicks and screens visited. In addition, we developed an overall Composite Eye Tracking score which measured when, where and how often each safety item was viewed. For 39 participants, the Composite Eye Tracking score correlated with performance on the simulation (p = 0.004). Overall, the improved performance was associated with a pattern of rapid scanning of data manifested by increased number of screens visited (p = 0.001), mouse clicks (p = 0.03) and saccades (p = 0.004). Eye tracking can be successfully integrated into electronic health record-based simulation and provides a surrogate measure of cognitive decision making and electronic health record usability. © The Author(s) 2015.
NASA Technical Reports Server (NTRS)
Koontz, S. L.; Kuminecz, J.; Leger, L.; Nordine, P.
1988-01-01
The use of thermal atom test methods as a materials selection and screening technique for low-Earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined to be in thermal atom environments are compared to those observed in LEO and in high quality LEO simulations. Reaction efficiencies measured in a new type of thermal atom apparatus are one-hundredth to one-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of 8 in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain specific thermal test environments can be used as reliable materials screening tools. Using thermal atom methods to predict material lifetime in LEO requires direct calibration of the method against LEO data or high quality simulation data for each material.
Evaluation of Arctic broadband surface radiation measurements
NASA Astrophysics Data System (ADS)
Matsui, N.; Long, C. N.; Augustine, J.; Halliwell, D.; Uttal, T.; Longenecker, D.; Niebergall, O.; Wendell, J.; Albee, R.
2012-02-01
The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW) and thermal infrared, or longwave (LW), radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers) and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse) SW measurements. The difference between these two quantities (that theoretically should be zero) is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.
Evaluation of arctic broadband surface radiation measurements
NASA Astrophysics Data System (ADS)
Matsui, N.; Long, C. N.; Augustine, J.; Halliwell, D.; Uttal, T.; Longenecker, D.; Nievergall, O.; Wendell, J.; Albee, R.
2011-08-01
The Arctic is a challenging environment for making in-situ radiation measurements. A standard suite of radiation sensors is typically designed to measure the total, direct and diffuse components of incoming and outgoing broadband shortwave (SW) and broadband thermal infrared, or longwave (LW) radiation. Enhancements can include various sensors for measuring irradiance in various narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that rotate sensors and shading devices that track the sun. High quality measurements require striking a balance between locating sensors in a pristine undisturbed location free of artificial blockage (such as buildings and towers) and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data include solar tracker malfunctions, rime/frost/snow deposition on the instruments and operational problems due to limited operator access in extreme weather conditions. In this study, a comparison is made between the global and component sum (direct [vertical component] + diffuse) shortwave measurements. The difference between these two quantities (that theoretically should be zero) is used to illustrate the magnitude and seasonality of radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both shortwave and longwave measurements. Solutions to these operational problems are proposed that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols.
The e-ASTROGAM mission. Exploring the extreme Universe with gamma rays in the MeV - GeV range
NASA Astrophysics Data System (ADS)
De Angelis, A.; Tatischeff, V.; Tavani, M.; Oberlack, U.; Grenier, I.; Hanlon, L.; Walter, R.; Argan, A.; von Ballmoos, P.; Bulgarelli, A.; Donnarumma, I.; Hernanz, M.; Kuvvetli, I.; Pearce, M.; Zdziarski, A.; Aboudan, A.; Ajello, M.; Ambrosi, G.; Bernard, D.; Bernardini, E.; Bonvicini, V.; Brogna, A.; Branchesi, M.; Budtz-Jorgensen, C.; Bykov, A.; Campana, R.; Cardillo, M.; Coppi, P.; De Martino, D.; Diehl, R.; Doro, M.; Fioretti, V.; Funk, S.; Ghisellini, G.; Grove, E.; Hamadache, C.; Hartmann, D. H.; Hayashida, M.; Isern, J.; Kanbach, G.; Kiener, J.; Knödlseder, J.; Labanti, C.; Laurent, P.; Limousin, O.; Longo, F.; Mannheim, K.; Marisaldi, M.; Martinez, M.; Mazziotta, M. N.; McEnery, J.; Mereghetti, S.; Minervini, G.; Moiseev, A.; Morselli, A.; Nakazawa, K.; Orleanski, P.; Paredes, J. M.; Patricelli, B.; Peyré, J.; Piano, G.; Pohl, M.; Ramarijaona, H.; Rando, R.; Reichardt, I.; Roncadelli, M.; Silva, R.; Tavecchio, F.; Thompson, D. J.; Turolla, R.; Ulyanov, A.; Vacchi, A.; Wu, X.; Zoglauer, A.
2017-10-01
e-ASTROGAM (`enhanced ASTROGAM') is a breakthrough Observatory space mission, with a detector composed by a Silicon tracker, a calorimeter, and an anticoincidence system, dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV - the lower energy limit can be pushed to energies as low as 150 keV, albeit with rapidly degrading angular resolution, for the tracker, and to 30 keV for calorimetric detection. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. Thanks to its performance in the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on the surroundings. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous generation instruments, e-ASTROGAM will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT, LSST, JWST, Athena, CTA, IceCube, KM3NeT, and the promise of eLISA.
Oxidation-resistant silicide coating applied to columbium alloy screen
NASA Technical Reports Server (NTRS)
Torgerson, R. T.
1971-01-01
Coated screens withstand temperature cycling in special transpiration-cooling systems and provide porous surface that is effective at temperatures well above those limiting superalloy screen efficiency. Thickness of coating depends on time, temperature and activator concentration. Coatings are uniform and resistant to thermal cycling.
Thermal Testing and Analysis of an Efficient High-Temperature Multi-Screen Internal Insulation
NASA Technical Reports Server (NTRS)
Weiland, Stefan; Handrick, Karin; Daryabeigi, Kamran
2007-01-01
Conventional multi-layer insulations exhibit excellent insulation performance but they are limited to the temperature range to which their components reflective foils and spacer materials are compatible. For high temperature applications, the internal multi-screen insulation IMI has been developed that utilizes unique ceramic material technology to produce reflective screens with high temperature stability. For analytical insulation sizing a parametric material model is developed that includes the main contributors for heat flow which are radiation and conduction. The adaptation of model-parameters based on effective steady-state thermal conductivity measurements performed at NASA Langley Research Center (LaRC) allows for extrapolation to arbitrary stack configurations and temperature ranges beyond the ones that were covered in the conductivity measurements. Experimental validation of the parametric material model was performed during the thermal qualification test of the X-38 Chin-panel, where test results and predictions showed a good agreement.
Crowther, Gregory J.; Napuli, Alberto J.; Thomas, Andrew P.; Chung, Diana J.; Kovzun, Kuzma V.; Leibly, David J.; Castaneda, Lisa J.; Bhandari, Janhavi; Damman, Christopher J.; Hui, Raymond; Hol, Wim G. J.; Buckner, Frederick S.; Verlinde, Christophe L. M. J.; Zhang, Zhongsheng; Fan, Erkang; Van Voorhis, Wesley C.
2010-01-01
In the last decade, thermal melt/thermal shift assays have become a common tool for identifying ligands and other factors that stabilize specific proteins. Increased stability is indicated by an increase in the protein's melting temperature (Tm). In optimizing the assays for subsequent screening of compound libraries, it is important to minimize the variability of Tm measurements so as to maximize the assay's ability to detect potential ligands. Here we present an investigation of Tm variability in recombinant proteins from Plasmodium parasites. Ligands of Plasmodium proteins are particularly interesting as potential starting points for drugs for malaria, and new drugs are urgently needed. A single standard buffer (100 mM HEPES, pH 7.5, 150 mM NaCl) permitted estimation of Tm for 58 of 61 Plasmodium proteins tested. However, with several proteins, Tm could not be measured with a consistency suitable for high-throughput screening unless alternative protein-specific buffers were employed. We conclude that buffer optimization to minimize variability in Tm measurements increases the success of thermal melt screens involving proteins for which a standard buffer is suboptimal. PMID:19470714
NASA Technical Reports Server (NTRS)
Li, Rongsheng (Inventor); Wu, Yeong-Wei Andy (Inventor); Hein, Douglas H. (Inventor)
2004-01-01
A method and apparatus for determining star tracker misalignments is disclosed. The method comprises the steps of defining a defining a reference frame for the star tracker assembly according to a boresight of the primary star tracker and a boresight of a second star tracker wherein the boresight of the primary star tracker and a plane spanned by the boresight of the primary star tracker and the boresight of the second star tracker at least partially define a datum for the reference frame for the star tracker assembly; and determining the misalignment of the at least one star tracker as a rotation of the defined reference frame.
NASA Astrophysics Data System (ADS)
Kim, Byung-Ho; Hwang, Jonghee; Lee, Young Jin; Kim, Jin-Ho; Jeon, Dae-Woo; Lee, Mi Jai
2016-08-01
We developed a fabrication method for remote phosphor by a screen-printing process, using green phosphor, red phosphor, and thermally stable glass frit. The glass frit was introduced for long-term stability. The optical properties of the remote phosphor were observed via an integrating sphere; the photoluminescence spectrum dramatically changed on incorporating a minor amount of the red phosphor. These unique optical properties were elucidated using four factors: phosphor ratio, scattering induced by packing density, light intensity per unit volume, and reabsorption. The thermal stability of the remote phosphor was investigated at 500°C, demonstrating its outstanding thermal properties.
Fabrication of aluminum-carbon composites
NASA Technical Reports Server (NTRS)
Novak, R. C.
1973-01-01
A screening, optimization, and evaluation program is reported of unidirectional carbon-aluminum composites. During the screening phase both large diameter monofilament and small diameter multifilament reinforcements were utilized to determine optimum precursor tape making and consolidation techniques. Difficulty was encountered in impregnating and consolidating the multifiber reinforcements. Large diameter monofilament reinforcement was found easier to fabricate into composites and was selected to carry into the optimization phase in which the hot pressing parameters were refined and the size of the fabricated panels was scaled up. After process optimization the mechanical properties of the carbon-aluminum composites were characterized in tension, stress-rupture and creep, mechanical fatigue, thermal fatigue, thermal aging, thermal expansion, and impact.
Integration and Testing of the Lunar Reconnaissance Orbiter Attitude Control System
NASA Technical Reports Server (NTRS)
Simpson, Jim; Badgley, Jason; McCaughey, Ken; Brown, Kristen; Calhoun, Philip; Davis, Edward; Garrick, Joseph; Gill, Nathaniel; Hsu, Oscar; Jones, Noble;
2010-01-01
Throughout the Lunar Reconnaissance Orbiter (LRO) Integration and Testing (I&T) phase of the project, the Attitude Control System (ACS) team completed numerous tests on each hardware component in ever more flight like environments. The ACS utilizes a select group of attitude sensors and actuators. This paper chronicles the evolutionary steps taken to verify each component was constantly ready for flight as well as providing invaluable trending experience with the actual hardware. The paper includes a discussion of each ACS hardware component, lessons learned of the various stages of I&T, a discussion of the challenges that are unique to the LRO project, as well as a discussion of work for future missions to consider as part of their I&T plan. LRO ACS sensors were carefully installed, tested, and maintained over the 18 month I&T and prelaunch timeline. Care was taken with the optics of the Adcole Coarse Sun Sensors (CSS) to ensure their critical role in the Safe Hold mode was fulfilled. The use of new CSS stimulators provided the means of testing each CSS sensor independently, in ambient and vacuum conditions as well as over a wide range of thermal temperatures. Extreme bright light sources were also used to test the CSS in ambient conditions. The integration of the two SELEX Galileo Star Trackers was carefully planned and executed. Optical ground support equipment was designed and used often to check the performance of the star trackers throughout I&T in ambient and thermal/vacuum conditions. A late discovery of potential contamination of the star tracker light shades is discussed in this paper. This paper reviews how each time the spacecraft was at a new location and orientation, the Honeywell Miniature Inertial Measurement Unit (MIMU) was checked for data output validity. This gyro compassing test was performed at several key testing points in the timeline as well as several times while LRO was on the launch pad. Sensor alignment tests were completed several times to ensure that hardware remained on a rigid platform.
Karlsson, Hanna L; Gliga, Anda R; Calléja, Fabienne M G R; Gonçalves, Cátia S A G; Wallinder, Inger Odnevall; Vrieling, Harry; Fadeel, Bengt; Hendriks, Giel
2014-09-02
The rapid expansion of manufacturing and use of nano-sized materials fuels the demand for fast and reliable assays to identify their potential hazardous properties and underlying mechanisms. The ToxTracker assay is a recently developed mechanism-based reporter assay based on mouse embryonic stem (mES) cells that uses GFP-tagged biomarkers for detection of DNA damage, oxidative stress and general cellular stress upon exposure. Here, we evaluated the ability of the ToxTracker assay to identify the hazardous properties and underlying mechanisms of a panel of metal oxide- and silver nanoparticles (NPs) as well as additional non-metallic materials (diesel, carbon nanotubes and quartz). The metal oxide- and silver nanoparticles were characterized in terms of agglomeration and ion release in cell medium (using photon cross correlation spectroscopy and inductively coupled plasma with optical emission spectroscopy, respectively) as well as acellular ROS production (DCFH-DA assay). Cellular uptake was investigated by means of transmission electron microscopy. GFP reporter induction and cytotoxicity of the NPs was simultaneously determined using flow cytometry, and genotoxicity was further tested using conventional assays (comet assay, γ-H2AX and RAD51 foci formation). We show that the reporter cells were able to take up nanoparticles and, furthermore, that exposure to CuO, NiO and ZnO nanoparticles as well as to quartz resulted in activation of the oxidative stress reporter, although only at high cytotoxicity for ZnO. NiO NPs activated additionally a p53-associated cellular stress response, indicating additional reactive properties. Conventional assays for genotoxicity assessment confirmed the response observed in the ToxTracker assay. We show for CuO NPs that the induction of oxidative stress is likely the consequence of released Cu ions whereas the effect by NiO was related to the particles per se. The DNA replication stress-induced reporter, which is most strongly associated with carcinogenicity, was not activated by any of the tested nanoparticles. We conclude that the ToxTracker reporter system can be used as a rapid mechanism-based tool for the identification of hazardous properties of metal oxide NPs. Furthermore, genotoxicity of metal oxide NPs seems to occur mainly via oxidative stress rather than direct DNA binding with subsequent replication stress.
NASA Technical Reports Server (NTRS)
Easterling, Donald F.; Hovanitz, Edward S.; Street, Kenneth W.
2000-01-01
A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.
A screen-printed flexible flow sensor
NASA Astrophysics Data System (ADS)
Moschos, A.; Syrovy, T.; Syrova, L.; Kaltsas, G.
2017-04-01
A thermal flow sensor was printed on a flexible plastic substrate using exclusively screen-printing techniques. The presented device was implemented with custom made screen-printed thermistors, which allows simple, cost-efficient production on a variety of flexible substrates while maintaining the typical advantages of thermal flow sensors. Evaluation was performed for both static (zero flow) and dynamic conditions using a combination of electrical measurements and IR imaging techniques in order to determine important characteristics, such as temperature response, output repeatability, etc. The flow sensor was characterized utilizing the hot-wire and calorimetric principles of operation, while the preliminary results appear to be very promising, since the sensor was successfully evaluated and displayed adequate sensitivity in a relatively wide flow range.
Cryogenic Capillary Screen Heat Entrapment
NASA Technical Reports Server (NTRS)
Bolshinskiy, L.G.; Hastings, L.J.; Stathman, G.
2007-01-01
Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of sub-cooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: "To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs.?"Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, "200x1400" and "325x2300", both with Twill Dutch Weave. Upon consideration of both the water and LN2 data it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.
Evaluation of thermal imaging technology for commercial vehicle screening.
DOT National Transportation Integrated Search
2015-12-01
Brake and tire violations are common problems identified through commercial vehicle inspections. Identifying and : correcting these types of problems before a crash occurs can produce significant safety benefits. Thermal imaging : technology can be u...
The Infrared Automatic Mass Screening (IRAMS) System For Printed Circuit Board Fault Detection
NASA Astrophysics Data System (ADS)
Hugo, Perry W.
1987-05-01
Office of the Program Manager for TMDE (OPM TMDE) has initiated a program to develop techniques for evaluating the performance of printed circuit boards (PCB's) using infrared thermal imaging. It is OPM TMDE's expectation that the standard thermal profile (STP) will become the basis for the future rapid automatic detection and isolation of gross failure mechanisms on units under test (UUT's). To accomplish this OPM TMDE has purchased two Infrared Automatic Mass Screening ( I RAMS) systems which are scheduled for delivery in 1987. The IRAMS system combines a high resolution infrared thermal imager with a test bench and diagnostic computer hardware and software. Its purpose is to rapidly and automatically compare the thermal profiles of a UUT with the STP of that unit, recalled from memory, in order to detect thermally responsive failure mechanisms in PCB's. This paper will review the IRAMS performance requirements, outline the plan for implementing the two systems and report on progress to date.
Thermal effusivity: a promising imaging biomarker to predict radiation-induced skin injuries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, J. C. H.; Templeton, A.; Yao, R.
An effective screening technology is needed to triage individuals at the time of radiation incidents involving a large population. Three-dimensional thermal tomography is a relatively new development in active thermal imaging technology that produces cross-sectional images based on the subject's ability to transfer heat thermal effusivity at the voxel level. This noninvasive imaging modality has been used successfully in nondestructive examination of complex materials; also it has been shown to predict the severity of radiation-induced skin injuries several days before the manifestation of severe moist desquamations or blister formation symptoms in mice at 40 Gy. If these results are confirmedmore » at lower dose levels in human subjects, a thermal tomography imaging device may be an ideal screening tool in radiation emergencies. This imaging method is non-invasive, relatively simple, easily adaptable for field use, and when properly deployed, it will enhance public emergency preparedness for incidents involving unexpected radiation exposure.« less
Ablinger, Elisabeth; Hellweger, Monika; Leitgeb, Stefan; Zimmer, Andreas
2012-10-15
In this study, we combined a high-throughput screening method, differential scanning fluorimetry (DSF), with design of experiments (DoE) methodology to evaluate the effects of several formulation components on the thermostability of granulocyte colony stimulating factor (G-CSF). First we performed a primary buffer screening where we tested thermal stability of G-CSF in different buffers, pH values and buffer concentrations. The significance of each factor and the two-way interactions between them were studied by multivariable regression analysis. pH was identified as most critical factor regarding thermal stability. The most stabilizing buffer, sodium glutamate, and sodium acetate were determined for further investigations. Second we tested the effect of 6 naturally occurring extremolytes (trehalose, sucrose, ectoine, hydroxyectoine, sorbitol, mannitol) on the thermal stability of G-CSF, using a central composite circumscribed design. At low pH (3.8) and low buffer concentration (5 mM) all extremolytes led to a significant increase in thermal stability except the addition of ectoine which resulted in a strong destabilization of G-CSF. Increasing pH and buffer concentration led to an increase in thermal stability with all investigated extremolytes. The described systematic approach allowed to create a ranking of stabilizing extremolytes at different buffer conditions. Copyright © 2012. Published by Elsevier B.V.
Meniscus Membranes For Separation
Dye, Robert C.; Jorgensen, Betty; Pesiri, David R.
2005-09-20
Gas separation membranes, especially meniscus-shaped membranes for gas separations are disclosed together with the use of such meniscus-shaped membranes for applications such as thermal gas valves, pre-concentration of a gas stream, and selective pre-screening of a gas stream. In addition, a rapid screening system for simultaneously screening polymer materials for effectiveness in gas separation is provided.
Optimization of protein buffer cocktails using Thermofluor.
Reinhard, Linda; Mayerhofer, Hubert; Geerlof, Arie; Mueller-Dieckmann, Jochen; Weiss, Manfred S
2013-02-01
The stability and homogeneity of a protein sample is strongly influenced by the composition of the buffer that the protein is in. A quick and easy approach to identify a buffer composition which increases the stability and possibly the conformational homogeneity of a protein sample is the fluorescence-based thermal-shift assay (Thermofluor). Here, a novel 96-condition screen for Thermofluor experiments is presented which consists of buffer and additive parts. The buffer screen comprises 23 different buffers and the additive screen includes small-molecule additives such as salts and nucleotide analogues. The utilization of small-molecule components which increase the thermal stability of a protein sample frequently results in a protein preparation of higher quality and quantity and ultimately also increases the chances of the protein crystallizing.
Analysis of protein stability and ligand interactions by thermal shift assay.
Huynh, Kathy; Partch, Carrie L
2015-02-02
Purification of recombinant proteins for biochemical assays and structural studies is time-consuming and presents inherent difficulties that depend on the optimization of protein stability. The use of dyes to monitor thermal denaturation of proteins with sensitive fluorescence detection enables rapid and inexpensive determination of protein stability using real-time PCR instruments. By screening a wide range of solution conditions and additives in a 96-well format, the thermal shift assay easily identifies conditions that significantly enhance the stability of recombinant proteins. The same approach can be used as an initial low-cost screen to discover new protein-ligand interactions by capitalizing on increases in protein stability that typically occur upon ligand binding. This unit presents a methodological workflow for small-scale, high-throughput thermal denaturation of recombinant proteins in the presence of SYPRO Orange dye. Copyright © 2015 John Wiley & Sons, Inc.
Thermal Protection System Aerothermal Screening Tests in HYMETS Facility
NASA Technical Reports Server (NTRS)
Szalai, Christine E.; Beck, Robin A. S.; Gasch, Matthew J.; Alumni, Antonella I.; Chavez-Garcia, Jose F.; Splinter, Scott C.; Gragg, Jeffrey G.; Brewer, Amy
2011-01-01
The Entry, Descent, and Landing (EDL) Technology Development Project has been tasked to develop Thermal Protection System (TPS) materials for insertion into future Mars Entry Systems. A screening arc jet test of seven rigid ablative TPS material candidates was performed in the Hypersonic Materials Environmental Test System (HYMETS) facility at NASA Langley Research Center, in both an air and carbon dioxide test environment. Recession, mass loss, surface temperature, and backface thermal response were measured for each test specimen. All material candidates survived the Mars aerocapture relevant heating condition, and some materials showed a clear increase in recession rate in the carbon dioxide test environment. These test results supported subsequent down-selection of the most promising material candidates for further development.
International standards for pandemic screening using infrared thermography
NASA Astrophysics Data System (ADS)
Pascoe, D. D.; Ring, E. F.; Mercer, J. B.; Snell, J.; Osborn, D.; Hedley-Whyte, J.
2010-03-01
The threat of a virulent strain of influenza, severe acute respiratory syndrome (SARS), tuberculosis, H1N1/A virus (swine flu) and possible mutations are a constant threat to global health. Implementation of pandemic infrared thermographic screening is based on the detection of febrile temperatures (inner canthus of the eyes) that are correlated with an infectious disease. Previous attempts at pandemic thermal screening have experienced problems (e.g. SARS outbreak, Singapore 2003) associated with the deployment plan, implementation and operation of the screening thermograph. Since this outbreak, the International Electrotechnical Commission has developed international standards that set minimum requirements for thermographic system fever screening and procedures that insure reliable and reproducible measurements. These requirements are published in IEC 80601-2-59:2008, Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening. The International Organization for Standardization has developed ISO/TR 13154:2009, Medical Electrical Equipment - which provides deployment, implementation and operational guidelines for identifying febrile humans using a screening thermograph. These new standards includes recommendations for camera calibrations, use of black body radiators, view field, focus, pixels within measurement site, image positioning, and deployment locations. Many current uses of thermographic screening at airports do not take into account critical issues addressed in the new standard, and are operating below the necessary effectiveness and efficiency. These documents, related thermal research, implications for epidemiology screening, and the future impact on medical thermography are discussed.
Optical Testing of Retroreflectors for Cryogenic Applications
NASA Technical Reports Server (NTRS)
Ohl, Raymond G.; Frey, Bradley J.; Stock, Joseph M.; McMann, Joseph C.; Zukowiski, Tmitri J.
2010-01-01
A laser tracker (LT) is an important coordinate metrology tool that uses laser interferometry to determine precise distances to objects, points, or surfaces defined by an optical reference, such as a retroreflector. A retroreflector is a precision optic consisting of three orthogonal faces that returns an incident laser beam nearly exactly parallel to the incident beam. Commercial retroreflectors are designed for operation at room temperature and are specified by the divergence, or beam deviation, of the returning laser beam, usually a few arcseconds or less. When a retroreflector goes to extreme cold (.35 K), however, it could be anticipated that the precision alignment between the three faces and the surface figure of each face would be compromised, resulting in wavefront errors and beam divergence, degrading the accuracy of the LT position determination. Controlled tests must be done beforehand to determine survivability and these LT coordinate errors. Since conventional interferometer systems and laser trackers do not operate in vacuum or at cold temperatures, measurements must be done through a vacuum window, and care must be taken to ensure window-induced errors are negligible, or can be subtracted out. Retroreflector holders must be carefully designed to minimize thermally induced stresses. Changes in the path length and refractive index of the retroreflector have to be considered. Cryogenic vacuum testing was done on commercial solid glass retroreflectors for use on cryogenic metrology tasks. The capabilities to measure wavefront errors, measure beam deviations, and acquire laser tracker coordinate data were demonstrated. Measurable but relatively small increases in beam deviation were shown, and further tests are planned to make an accurate determination of coordinate errors.
Optical Correlation Techniques In Fluid Dynamics
NASA Astrophysics Data System (ADS)
Schatzel, K.; Schulz-DuBois, E. O.; Vehrenkamp, R.
1981-05-01
Three flow measurement techniques make use of fast digital correlators. (1) Most widely spread is photon correlation velocimetry using crossed laser beams and detecting Doppler shifted light scattered by small particles in the flow. Depending on the processing of the photon correlogram, this technique yields mean velocity, turbulence level, or even the detailed probability distribution of one velocity component. An improved data processing scheme is demonstrated on laminar vortex flow in a curved channel. (2) Rate correlation based upon threshold crossings of a high pass filtered laser Doppler signal can he used to obtain velocity correlation functions. The most powerful setup developed in our laboratory uses a phase locked loop type tracker and a multibit correlator to analyse time-dependent Taylor vortex flow. With two optical systems and trackers, crosscorrelation functions reveal phase relations between different vortices. (3) Making use of refractive index fluctuations (e. g. in two phase flows) instead of scattering particles, interferometry with bidirectional fringe counting and digital correlation and probability analysis constitute a new quantitative technique related to classical Schlieren methods. Measurements on a mixing flow of heated and cold air contribute new ideas to the theory of turbulent random phase screens.
Optical correlation techniques in fluid dynamics
NASA Astrophysics Data System (ADS)
Schätzel, K.; Schulz-Dubois, E. O.; Vehrenkamp, R.
1981-04-01
Three flow measurement techniques make use of fast digital correlators. The most widely spread is photon correlation velocimetry using crossed laser beams, and detecting Doppler shifted light scattered by small particles in the flow. Depending on the processing of the photon correlation output, this technique yields mean velocity, turbulence level, and even the detailed probability distribution of one velocity component. An improved data processing scheme is demonstrated on laminar vortex flow in a curved channel. In the second method, rate correlation based upon threshold crossings of a high pass filtered laser Doppler signal can be used to obtain velocity correlation functions. The most powerful set-up developed in our laboratory uses a phase locked loop type tracker and a multibit correlator to analyze time-dependent Taylor vortex flow. With two optical systems and trackers, cross-correlation functions reveal phase relations between different vortices. The last method makes use of refractive index fluctuations (eg in two phase flows) instead of scattering particles. Interferometry with bidirectional counting, and digital correlation and probability analysis, constitutes a new quantitative technique related to classical Schlieren methods. Measurements on a mixing flow of heated and cold air contribute new ideas to the theory of turbulent random phase screens.
Chapter 6: CPV Tracking and Trackers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luque-Heredia, Ignacio; Magalhaes, Pedro; Muller, Matthew
2016-04-15
This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurementmore » with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.« less
Orion Optical Navigation Progress Toward Exploration: Mission 1
NASA Technical Reports Server (NTRS)
Holt, Greg N.; D'Souza, Christopher N.; Saley, David
2018-01-01
Optical navigation of human spacecraft was proposed on Gemini and implemented successfully on Apollo as a means of autonomously operating the vehicle in the event of lost communication with controllers on Earth. It shares a history with the "method of lunar distances" that was used in the 18th century and gained some notoriety after its use by Captain James Cook during his 1768 Pacific voyage of the HMS Endeavor. The Orion emergency return system utilizing optical navigation has matured in design over the last several years, and is currently undergoing the final implementation and test phase in preparation for Exploration Mission 1 (EM-1) in 2019. The software development is being worked as a Government Furnished Equipment (GFE) project delivered as an application within the Core Flight Software of the Orion camera controller module. The mathematical formulation behind the initial ellipse fit in the image processing is detailed in Christian. The non-linear least squares refinement then follows the technique of Mortari as an estimation process of the planetary limb using the sigmoid function. The Orion optical navigation system uses a body fixed camera, a decision that was driven by mass and mechanism constraints. The general concept of operations involves a 2-hour pass once every 24 hours, with passes specifically placed before all maneuvers to supply accurate navigation information to guidance and targeting. The pass lengths are limited by thermal constraints on the vehicle since the OpNav attitude generally deviates from the thermally stable tail-to-sun attitude maintained during the rest of the orbit coast phase. Calibration is scheduled prior to every pass due to the unknown nature of thermal effects on the lens distortion and the mounting platform deformations between the camera and star trackers. The calibration technique is described in detail by Christian, et al. and simultaneously estimates the Brown-Conrady coefficients and the Star Tracker/Camera interlock angles. Accurate attitude information is provided by the star trackers during each pass. Figure 1 shows the various phases of lunar return navigation when the vehicle is in autonomous operation with lost ground communication. The midcourse maneuvers are placed to control the entry interface conditions to the desired corridor for safe landing. The general form of optical navigation on Orion is where still images of the Moon or Earth are processed to find the apparent angular diameter and centroid in the camera focal plane. This raw data is transformed into range and bearing angle measurements using planetary data and precise star tracker inertial attitude. The measurements are then sent to the main flight computer's Kalman filter to update the onboard state vector. The images are, of course, collected over an arc to converge the state and estimate velocity. The same basic technique was used by Apollo to satisfy loss-of-comm, but Apollo used manual crew sightings with a vehicle-integral sextant instead of autonomously processing optical imagery. The software development is past its Critical Design Review, and is progressing through test and certification for human rating. In support of this, a hardware-in-the-loop test rig was developed in the Johnson Space Center Electro-Optics Lab to exercise the OpNav system prior to integrated testing on the Orion vehicle. Figure 2 shows the rig, which the test team has dubbed OCILOT (Orion Camera In the Loop Optical Testbed). Analysis performed to date shows a delivery that satisfies an allowable entry corridor as shown in Figure 3.
Thermal neutron scintillators using unenriched boron nitride and zinc sulfide
NASA Astrophysics Data System (ADS)
McMillan, J. E.; Cole, A. J.; Kirby, A.; Marsden, E.
2015-06-01
Thermal neutron detectors based on powdered zinc sulfide intimately mixed with a neutron capture compound have a history as long as scintillation technique itself. We show that using unenriched boron nitride powder, rather than the more commonly used enriched lithium fluoride, results in detection screens which produce less light but which are very considerably cheaper. Methods of fabricating large areas of this material are presented. The screens are intended for the production of large area low cost neutron detectors as a replacement for helium-3 proportional tubes.
Thermal Performance of a Cryogenic Fluid Management Cubesat Mission
NASA Technical Reports Server (NTRS)
Berg, J. J.; Oliveira, J. M.; Congiardo, J. F.; Walls, L. K.; Putman, P. T.; Haberbusch, M. S.
2013-01-01
Development for an in-space demonstration of a CubeS at as a Cryogenic Fluid Management (CFM) test bed is currently underway. The favorable economics of CubeSats make them appealing for technology development activity. While their size limits testing to smaller scales, many of the regimes relevant to CFM can still be achieved. The first demo flight of this concept, CryoCube®-1, will focus on oxygen liquefaction and low-gravity level sensing using Reduced Gravity CryoTracker®. An extensive thermal modeling effort has been underway to both demonstrate concept feasibility and drive the prototype design. The satellite will utilize both a sun- and earth-shield to passively cool its experimental tank below 115 K. An on-board gas generator will create high pressure gaseous oxygen, which will be throttled into a bottle in the experimental node and condensed. The resulting liquid will be used to perform various experiments related to level sensing. Modeling efforts have focused on the spacecraft thermal performance and its effects on condensation in the experimental node. Parametric analyses for both optimal and suboptimal conditions have been considered and are presented herein.
Capillary Liquid Acquisition Device Heat Entrapment
NASA Technical Reports Server (NTRS)
Bolshinskiy, L. G.; Hastings, L. J.; Statham, G.; Turpin, J. B.
2007-01-01
Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of subcooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs? Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, 200x1400 and 325x2300, both with Twill Dutch Weave. Upon consideration of both the water and LN2 data, it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.
Zhitomirsky, Benny; Farber, Hodaya; Assaraf, Yehuda G
2018-04-01
LysoTracker and MitoTracker Red are fluorescent probes widely used for viable cell staining of lysosomes and mitochondria, respectively. They are utilized to study organelle localization and their resident proteins, assess organelle functionality and quantification of organelle numbers. The ATP-driven efflux transporter P-glycoprotein (P-gp) is expressed in normal and malignant tissues and extrudes structurally distinct endogenous and exogenous cytotoxic compounds. Thus, once aromatic hydrophobic compounds such as the above-mentioned fluorescent probes are recognized as transport substrates, efflux pumps including P-gp may abolish their ability to reach their cellular target organelles. Herein, we show that LysoTracker and MitoTracker Red are expelled from P-gp-overexpressing cancer cells, thus hindering their ability to fluorescently mark target organelles. We further demonstrate that tariquidar, a potent P-gp transport inhibitor, restores LysoTracker and MitoTracker Red cell entry. We conclude that LysoTracker and MitoTracker Red are P-gp transport substrates, and therefore, P-gp expression must be taken into consideration prior to cellular applications using these probes. Importantly, as MitoTracker was a superior P-gp substrate than LysoTracker Red, we discuss the implications for the future design of chemotherapeutics evading cancer multidrug resistance. Furthermore, restoration of MitoTracker Red fluorescence in P-gp-overexpressing cells may facilitate the identification of potent P-gp transport inhibitors (i.e. chemosensitizers). © 2018 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Dillon, Neal P; Fichera, Loris; Kesler, Kyle; Zuniga, M Geraldine; Mitchell, Jason E; Webster, Robert J; Labadie, Robert F
2017-09-01
This article presents the development and experimental validation of a methodology to reduce the risk of thermal injury to the facial nerve during minimally invasive cochlear implantation surgery. The first step in this methodology is a pre-operative screening process, in which medical imaging is used to identify those patients that present a significant risk of developing high temperatures at the facial nerve during the drilling phase of the procedure. Such a risk is calculated based on the density of the bone along the drilling path and the thermal conductance between the drilling path and the nerve, and provides a criterion to exclude high-risk patients from receiving the minimally invasive procedure. The second component of the methodology is a drilling strategy for manually-guided drilling near the facial nerve. The strategy utilizes interval drilling and mechanical constraints to enable better control over the procedure and the resulting generation of heat. The approach is tested in fresh cadaver temporal bones using a thermal camera to monitor temperature near the facial nerve. Results indicate that pre-operative screening may successfully exclude high-risk patients and that the proposed drilling strategy enables safe drilling for low-to-moderate risk patients.
NASA Astrophysics Data System (ADS)
Bruce, Romain; Baudouy, Bertrand
The Space Radiation Superconducting Shield (SR2S) European project aims at studying a large superconducting toroid magnet to protect the human habitat from the ionizing radiations coming from Galactic Cosmic Ray during long term missions in deep space. Titanium clad MgB2 conductor is used to afford a bending power greater than 5 T.m at 10 K. A specific cryogenic design is needed to cool down this 10 m long and 12.8 m in diameter magnet. A passive cooling system, using a V-groove sunshield, is considered to reduce the heat flux coming from the Sun or Mars. An active configuration, using pulse tube cryocoolers, will be linked to the 80 K thermal screen intercepting most of the heat fluxes coming from the human habitat. The toroid magnet will be connected also to cryocoolers to absorb the few watts reaching its surface. Two kinds of thermal link are being considered to absorb the heat on the 80 K thermal screen. The first one is active, with a pump circulating helium gas in a network of exchange tubes. The second one is passive using long cryogenic pulse heat pipe (PHP) with the evaporator on the surface of the thermal screen and the condenser attached to the pulse tube.
Arsham, Andrew M; Neufeld, Thomas P
2009-06-29
The highly conserved autophagy-lysosome pathway is the primary mechanism for breakdown and recycling of macromolecular and organellar cargo in the eukaryotic cell. Autophagy has recently been implicated in protection against cancer, neurodegeneration, and infection, and interest is increasing in additional roles of autophagy in human health, disease, and aging. To search for novel cytoprotective features of this pathway, we carried out a genetic mosaic screen for mutations causing increased lysosomal and/or autophagic activity in the Drosophila melanogaster larval fat body. By combining Drosophila genetics with live-cell imaging of the fluorescent dye LysoTracker Red and fixed-cell imaging of autophagy-specific fluorescent protein markers, the screen was designed to identify essential metazoan genes whose disruption causes increased flux through the autophagy-lysosome pathway. The screen identified a large number of genes associated with the protein synthesis and ER-secretory pathways (e.g. aminoacyl tRNA synthetases, Oligosaccharyl transferase, Sec61alpha), and with mitochondrial function and dynamics (e.g. Rieske iron-sulfur protein, Dynamin-related protein 1). We also observed that increased lysosomal and autophagic activity were consistently associated with decreased cell size. Our work demonstrates that disruption of the synthesis, transport, folding, or glycosylation of ER-targeted proteins at any of multiple steps leads to autophagy induction. In addition to illuminating cytoprotective features of autophagy in response to cellular damage, this screen establishes a genetic methodology for investigating cell biological phenotypes in live cells, in the context of viable wild type organisms.
GeoCARB design maturity and geostationary heritage
NASA Astrophysics Data System (ADS)
Sawyer, Kevin; Clark, Charles; Katz, Noah; Kumar, Jack; Nast, Ted; Palmer, Alice
2013-09-01
Our companion paper `Progress in development of Tropospheric Infrared Mapping Spectrometers (TIMS): geostationary greenhouse gas (GHG) application' describes geoCARB performance and science. Here we describe a geoCARB instrument design study leading to near PDR maturity. It is based on heritage geostationary (AIA and HMI on SDO, SBIRS GEO-1 and upcoming GLM on GOES-R as examples) and other (IRIS and NIRcam) flight instrumentation. Heritage work includes experience and well developed specifications for near a-thermal carbon fiber honeycomb composite optical benches and optical element mounting design forms that utilize a "family" of mounts for nearly any type of optical element. The geoCARB approach utilizes composite optical benches and bipod flexures to kinematically mount optics. Tooling for alignment and staking of all elements is integral to the design and is "removed before flight" for mass minimization. GeoCARB requires a cryogenic region for focal planes and spectrometers but front end optics and main structure are designed to run much warmer. A star tracker is used for geoCARB posteriori geolocation including pseudo-diurnal thermal distortion characterization. It is kinematically mounted by low conductance thermal isolators directly on to the low expansion high stiffness composite bench that defines the master optical surfaces including the scanning mirrors. The thermal load from the camera heads is routed away from the bench heat pipes. Use of kinematic mounting is advantageous for low thermal conduction designs. Honeycomb composites enable the design's low thermal mechanical distortions.
Fusion of P300 and eye-tracker data for spelling using BCI2000
NASA Astrophysics Data System (ADS)
Kalika, Dmitry; Collins, Leslie; Caves, Kevin; Throckmorton, Chandra
2017-10-01
Objective. Various augmentative and alternative communication (AAC) devices have been developed in order to aid communication for individuals with communication disorders. Recently, there has been interest in combining EEG data and eye-gaze data with the goal of developing a hybrid (or ‘fused’) BCI (hBCI) AAC system. This work explores the effectiveness of a speller that fuses data from an eye-tracker and the P300 speller in order to create a hybrid P300 speller. Approach. This hybrid speller collects both eye-tracking and EEG data in parallel, and the user spells characters on the screen in the same way that they would if they were only using the P300 speller. Online and offline experiments were performed. The online experiments measured the performance of the speller for sixteen non-disabled participants, while the offline simulations were used to assess the robustness of the hybrid system. Main results. Online results showed that for fifteen non-disabled participants, using eye-gaze in a Bayesian framework with EEG data from the P300 speller improved accuracy (0.0163+/- 2.72 , 0.085+/- 0.111 , 0.080+/- 0.106 for estimated, medium and high variance configurations) and reduced the average number of flashes required to spell a character compared to the standard P300 speller that relies solely on EEG data (-53.27+/- 25.87 , -36.15+/- 19.3 , -18.85+/- 12.43 for estimated, medium and high variance configurations). Offline simulations indicate that the system provides more robust performance than a standalone eye gaze system. Significance. The results of this work on non-disabled participants shows the potential efficacy of hybrid P300 and eye-tracker speller. Further validation on the amyotrophic lateral sceloris population is needed to assess the benefit of this hybrid system.
Gualtieri, Lisa; Rosenbluth, Sandra; Phillips, Jeffrey
2016-11-30
Wearable activity trackers (trackers) are increasingly popular devices used to track step count and other health indicators. Trackers have the potential to benefit those in need of increased physical activity, such as adults who are older and face significant health challenges. These populations are least likely to purchase trackers and most likely to face challenges in using them, yet may derive educational, motivational, and health benefits from their use once these barriers are removed. The aim of this pilot research is to investigate the use of trackers by adults with chronic medical conditions who have never used trackers previously. Specifically, we aim to determine (1) if participants would accept and use trackers to increase their physical activity; (2) if there were barriers to use besides cost and training; (3) if trackers would educate participants on their baseline and ongoing activity levels and support behavior change; and (4) if clinical outcomes would show improvements in participants' health. This study was conducted with patients (N=10) in a 12-week physician-led wellness group offered by Family Doctors, LLC. Patients were given trackers in the second week of The Wellness Group and were interviewed 2 to 4 weeks after it ended. The study investigators analyzed the interview notes to extract themes about the participants' attitudes and behavior changes and collected and analyzed participants' clinical data, including weight and low-density lipoprotein (LDL) cholesterol over the course of the study. Over the 12 to 14 weeks of tracker use, improvements were seen in clinical outcomes, attitudes towards the trackers, and physical activity behaviors. Participants lost an average of 0.5 lbs per week (SD 0.4), with a mean total weight loss of 5.97 lbs (P=.004). Other short-term clinical outcomes included a 9.2% decrease in LDL levels (P=.038). All participants reported an increase in well-being and confidence in their ability to lead more active lives. We identified the following 6 major attitudinal themes from our qualitative analysis of the interview notes: (1) barriers to tracker purchase included cost, perceived value, and choice confusion; (2) attitudes towards the trackers shifted for many, from half of the participants expressing excitement and hope and half expressing hesitation or trepidation, to all participants feeling positive towards their tracker at the time of the interviews; (3) trackers served as educational tools for baseline activity levels; (4) trackers provided concrete feedback on physical activity, which motivated behavior change; (5) tracker use reinforced wellness group activities and goals; and (6) although commitment to tracker use did not waver, external circumstances influenced some participants' ongoing use. Our findings suggest that adding trackers to wellness groups comprising primarily older adults with chronic medical conditions can support education and behavior change to be more physically active. The trackers increased participant self-efficacy by providing a tangible, visible reminder of a commitment to increasing activity and immediate feedback on step count and progress towards a daily step goal. While acceptance was high and attitudes ultimately positive, training and support are needed and short-term drop-off in participant use is to be expected. Future research will further consider the potential of trackers in older adults with chronic medical conditions who are unlikely to purchase them, and studies will use larger samples, continue over a longer period of time, and evaluate outcomes independent of a wellness group. ©Lisa Gualtieri, Sandra Rosenbluth, Jeffrey Phillips. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 30.11.2016.
Thermal imaging in screening of joint inflammation and rheumatoid arthritis in children.
Lasanen, R; Piippo-Savolainen, E; Remes-Pakarinen, T; Kröger, L; Heikkilä, A; Julkunen, P; Karhu, J; Töyräs, J
2015-02-01
Potential of modern thermal imaging for screening and differentiation of joint inflammation has not been assessed in child and juvenile patient populations, typically demanding groups in diagnostics of musculoskeletal disorders. We hypothesize that thermal imaging can detect joint inflammation in patients with juvenile idiopathic arthritis or autoimmune disease with arthritis such as systemic lupus erythematosus. To evaluate the hypothesis, we studied 58 children exhibiting symptoms of joint inflammation. First, the patients' joints were examined along clinical procedure supplemented with ultrasound imaging when deemed necessary by the clinician. Second, thermal images were acquired from patients' knees and ankles. Results of thermal imaging were compared to clinical evaluations in knee and ankle. The temperatures were significantly (pmax = 0.044, pmean < 0.001) higher in inflamed ankle joints, but not in inflamed knee joints. No significant difference was found between the skin surface temperatures of medial and lateral aspects of ankle joints. In knee joints the mean temperatures of medial and lateral aspect differed significantly (p = 0.004). We have demonstrated that thermal imaging may have potential for detecting joint inflammation in ankle joints of children. For knee joints our results are inconclusive and further research is warranted.
Schlehuber, Lisa D; McFadyen, Iain J; Shu, Yu; Carignan, James; Duprex, W Paul; Forsyth, William R; Ho, Jason H; Kitsos, Christine M; Lee, George Y; Levinson, Douglas A; Lucier, Sarah C; Moore, Christopher B; Nguyen, Niem T; Ramos, Josephine; Weinstock, B André; Zhang, Junhong; Monagle, Julie A; Gardner, Colin R; Alvarez, Juan C
2011-07-12
As a result of thermal instability, some live attenuated viral (LAV) vaccines lose substantial potency from the time of manufacture to the point of administration. Developing regions lacking extensive, reliable refrigeration ("cold-chain") infrastructure are particularly vulnerable to vaccine failure, which in turn increases the burden of disease. Development of a robust, infectivity-based high throughput screening process for identifying thermostable vaccine formulations offers significant promise for vaccine development across a wide variety of LAV products. Here we describe a system that incorporates thermal stability screening into formulation design using heat labile measles virus as a prototype. The screening of >11,000 unique formulations resulted in the identification of liquid formulations with marked improvement over those used in commercial monovalent measles vaccines, with <1.0 log loss of activity after incubation for 8h at 40°C. The approach was shown to be transferable to a second unrelated virus, and therefore offers significant promise towards the optimization of formulation for LAV vaccine products. Copyright © 2011 Elsevier Ltd. All rights reserved.
Sun-Relative Pointing for Dual-Axis Solar Trackers Employing Azimuth and Elevation Rotations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riley, Daniel; Hansen, Clifford W.
Dual axis trackers employing azimuth and elevation rotations are common in the field of photovoltaic (PV) energy generation. Accurate sun-tracking algorithms are widely available. However, a steering algorithm has not been available to accurately point the tracker away from the sun such that a vector projection of the sun beam onto the tracker face falls along a desired path relative to the tracker face. We have developed an algorithm which produces the appropriate azimuth and elevation angles for a dual axis tracker when given the sun position, desired angle of incidence, and the desired projection of the sun beam ontomore » the tracker face. Development of this algorithm was inspired by the need to accurately steer a tracker to desired sun-relative positions in order to better characterize the electro-optical properties of PV and CPV modules.« less
NASA Astrophysics Data System (ADS)
Kelber, C.; Marke, S.; Trommler, U.; Rupprecht, C.; Weis, S.
2017-03-01
Thermal spraying processes are becoming increasingly important in high-technology areas, such as automotive engineering and medical technology. The method offers the advantage of a local layer application with different materials and high deposition rates. Challenges in the application of thermal spraying result from the complex interaction of different influencing variables, which can be attributed to the properties of different materials, operating equipment supply, electrical parameters, flow mechanics, plasma physics and automation. In addition, spraying systems are subject to constant wear. Due to the process specification and the high demands on the produced coatings, innovative quality assurance tools are necessary. A central aspect, which has not yet been considered, is the data management in relation to the present measured variables, in particular the spraying system, the handling system, working safety devices and additional measuring sensors. Both the recording of all process-characterizing variables, their linking and evaluation as well as the use of the data for the active process control presuppose a novel, innovative control system (hardware and software) that was to be developed within the scope of the research project. In addition, new measurement methods and sensors are to be developed and qualified in order to improve the process reliability of thermal spraying.
Systems evaluation of thermal bus concepts
NASA Technical Reports Server (NTRS)
Stalmach, D. D.
1982-01-01
Thermal bus concepts, to provide a centralized thermal utility for large, multihundred kilowatt space platforms, were studied and the results are summarized. Concepts were generated, defined, and screened for inclusion in system level thermal bus trades. Parametric trade studies were conducted in order to define the operational envelope, performance, and physical characteristics of each. Two concepts were selected as offering the most promise for thermal bus development. All of four concepts involved two phase flow in order to meet the required isothermal nature of the thermal bus. Two of the concepts employ a mechanical means to circulate the working fluid, a liquid pump in one case and a vapor compressor in another. Another concept utilizes direct osmosis as the driving force of the thermal bus. The fourth concept was a high capacity monogroove heat pipe. After preliminary sizing and screening, three of these concepts were selected to carry into the trade studies. The monogroove heat pipe concept was deemed unsuitable for further consideration because of its heat transport limitations. One additional concept utilizing capillary forces to drive the working fluid was added. Parametric system level trade studies were performed. Sizing and weight calculations were performed for thermal bus sizes ranging from 5 to 350 kW and operating temperatures in the range of 4 to 120 C. System level considerations such as heat rejection and electrical power penalties and interface temperature losses were included in the weight calculations.
Chen, Janice D; Falkmer, Torbjörn; Parsons, Richard; Buzzard, Jennifer; Ciccarelli, Marina
2014-05-01
The Rapid Upper Limb Assessment (RULA) is an observation-based screening tool that has been used to assess postural risks of children in school settings. Studies using eye-tracking technology suggest that visual search strategies are influenced by experience in the task performed. This study investigated if experience in postural risk assessments contributed to differences in outcome scores on the RULA and the visual search strategies utilized. While wearing an eye-tracker, 16 student occupational therapists and 16 experienced occupational therapists used the RULA to assess 11 video scenarios of a child using different mobile information and communication technologies (ICT) in the home environment. No significant differences in RULA outcome scores, and no conclusive differences in visual search strategies between groups were found. RULA can be used as a screening tool for postural risks following a short training session regardless of the assessor's experience in postural risk assessments. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Automatic colonic lesion detection and tracking in endoscopic videos
NASA Astrophysics Data System (ADS)
Li, Wenjing; Gustafsson, Ulf; A-Rahim, Yoursif
2011-03-01
The biology of colorectal cancer offers an opportunity for both early detection and prevention. Compared with other imaging modalities, optical colonoscopy is the procedure of choice for simultaneous detection and removal of colonic polyps. Computer assisted screening makes it possible to assist physicians and potentially improve the accuracy of the diagnostic decision during the exam. This paper presents an unsupervised method to detect and track colonic lesions in endoscopic videos. The aim of the lesion screening and tracking is to facilitate detection of polyps and abnormal mucosa in real time as the physician is performing the procedure. For colonic lesion detection, the conventional marker controlled watershed based segmentation is used to segment the colonic lesions, followed by an adaptive ellipse fitting strategy to further validate the shape. For colonic lesion tracking, a mean shift tracker with background modeling is used to track the target region from the detection phase. The approach has been tested on colonoscopy videos acquired during regular colonoscopic procedures and demonstrated promising results.
Testing FlowTracker2 Performance and Wading Rod Flow Disturbance in Laboratory Tow Tanks
NASA Astrophysics Data System (ADS)
Fan, X.; Wagenaar, D.
2016-12-01
The FlowTracker2 was released in February 2016 by SonTek (Xylem) to be a more feature-rich and technologically advanced replacement to the Original FlowTracker ADV. These instruments are Acoustic Doppler Velocimeters (ADVs) used for taking high-precision wading discharge and velocity measurements. The accuracy of the FlowTracker2 probe was tested in tow tanks at three different facilities: the USGS Hydrologic Instrumentation Facility (HIF), the Swiss Federal Institute for Metrology (METAS), and at the SonTek Research and Development facility. Multiple mounting configurations were examined, including mounting the ADV probe directly to the tow carts, and incorporating the two most-used wading rods for the FlowTracker (round and hex). Tow speeds ranged from 5cm/s to 1.5m/s, and different tow tank seeding schemes and wait times were examined. In addition, the performance of the FlowTracker2 probe in low Signal-to-Noise Ratio (SNR) environments was compared to the Original FlowTracker ADV. Results confirmed that the FlowTracker2 probe itself performed well within the 1%+0.25cm/s accuracy specification advertised. Tows using the wading rods created a reduced measured velocity by 1.3% of the expected velocity due to flow disturbance, a result similar to the Original FlowTracker ADV despite the change in the FlowTracker2 probe design. Finally, due to improvements in its electronics, the FlowTracker2's performance in low SNR tests exceeded that of the Original FlowTracker ADV, showing less standard error in these conditions compared to its predecessor.
NASA Astrophysics Data System (ADS)
Realmuto, V. J.; Berk, A.; Guiang, C.
2014-12-01
Infrared remote sensing is a vital tool for the study of volcanic plumes, and radiative transfer (RT) modeling is required to derive quantitative estimation of the sulfur dioxide (SO2), sulfate aerosol (SO4), and silicate ash (pulverized rock) content of these plumes. In the thermal infrared, we must account for the temperature, emissivity, and elevation of the surface beneath the plume, plume altitude and thickness, and local atmospheric temperature and humidity. Our knowledge of these parameters is never perfect, and interactive mapping allows us to evaluate the impact of these uncertainties on our estimates of plume composition. To enable interactive mapping, the Jet Propulsion Laboratory is collaborating with Spectral Sciences, Inc., (SSI) to develop the Plume Tracker toolkit. This project is funded by a NASA AIST Program Grant (AIST-11-0053) to SSI. Plume Tracker integrates (1) retrieval procedures for surface temperature and emissivity, SO2, NH3, or CH4 column abundance, and scaling factors for H2O vapor and O3 profiles, (2) a RT modeling engine based on MODTRAN, and (3) interactive visualization and analysis utilities under a single graphics user interface. The principal obstacle to interactive mapping is the computational overhead of the RT modeling engine. Under AIST-11-0053 we have achieved a 300-fold increase in the performance of the retrieval procedures through the use of indexed caches of model spectra, optimization of the minimization procedures, and scaling of the effects of surface temperature and emissivity on model radiance spectra. In the final year of AIST-11-0053 we will implement parallel processing to exploit multi-core CPUs and cluster computing, and optimize the RT engine to eliminate redundant calculations when iterating over a range of gas concentrations. These enhancements will result in an additional 8 - 12X increase in performance. In addition to the improvements in performance, we have improved the accuracy of the Plume Tracker retrievals through refinements in the description of surface emissivity and use of vector projection to define the misfit between model and observed spectra. Portions of this research were conducted at the Jet Propulsion Laboratory, California Institute of Technology, under contract to the National Aeronautics and Space Administration.
DiFeliceantonio, Alexandra G.; Berridge, Kent C.
2012-01-01
Pavlovian cues that have been paired with reward can gain incentive salience. Drug addicts find drug cues motivationally attractive and binge eaters are attracted by food cues. But the level of incentive salience elicited by a cue re-encounter still varies across time and brain states. In an animal model, cues become attractive and ‘wanted’ in an ‘autoshaping’ paradigm, where different targets of incentive salience emerge for different individuals. Some individuals (sign-trackers) find a predictive discrete cue attractive while others find a reward contiguous and goal cue more attractive (location where reward arrives: goal-trackers). Here we assessed whether central amygdala mu opioid receptor stimulation enhances the phasic incentive salience of the goal-cue for goal-trackers during moments of predictive cue presence (expressed in both approach and consummatory behaviors to goal cue), just as it enhances the attractiveness of the predictive cue target for sign-trackers. Using detailed video analysis we measured the approaches, nibbles, sniffs, and bites directed at their preferred target for both sign-trackers and goal-trackers. We report that DAMGO microinjections in central amygdala made goal-trackers, like sign-trackers, show phasic increases in appetitive nibbles and sniffs directed at the goal-cue expressed selectively whenever the predictive cue was present. This indicates enhancement of incentive salience attributed by both goal trackers and sign-trackers, but attributed in different directions: each to their own target cue. For both phenotypes, amygdala opioid stimulation makes the individual’s prepotent cue into a stronger motivational magnet at phasic moments triggered by a CS that predicts the reward UCS. PMID:22391118
An on-line acoustic fluorocarbon coolant mixture analyzer for the ATLAS silicon tracker
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bates, R.; Battistin, M.; Berry, S.
2011-07-01
The ATLAS silicon tracker community foresees an upgrade from the present octafluoro-propane (C{sub 3}F{sub 8}) evaporative cooling fluid - to a composite fluid with a probable 10-20% admixture of hexafluoro-ethane (C{sub 2}F{sub 6}). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C{sub 3}F{sub 8}/C{sub 2}F{sub 6} mixturemore » ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound 'chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C{sub 3}F{sub 8}/C{sub 2}F{sub 6} flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semiconductor manufacture and anesthetic gas mixtures. (authors)« less
An On-Line Acoustic Fluorocarbon Coolant Mixture Analyzer for the ATLAS Silicon Tracker
NASA Astrophysics Data System (ADS)
Bates, R.; Battistin, M.; Berry, S.; Bitadze, A.; Bonneau, P.; Bousson, N.; Boyd, G.; Botelho-Direito, J.; DiGirolamo, B.; Doubek, M.; Egorov, K.; Godlewski, J.; Hallewell, G.; Katunin, S.; Mathieu, M.; McMahon, S.; Nagai, K.; Perez-Rodriguez, E.; Rozanov, A.; Vacek, V.; Vitek, M.
2012-10-01
The ATLAS silicon tracker community foresees an upgrade from the present octafluoropropane (C3F8) evaporative cooling fluid to a composite fluid with a probable 10-20% admixture of hexafluoroethane (C2F6). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C3F8/C2F6 mixture ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound `chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C3F8/C2F6 flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semi-conductor manufacture and anesthetic gas mixtures.
Autonomous star tracker based on active pixel sensors (APS)
NASA Astrophysics Data System (ADS)
Schmidt, U.
2017-11-01
Star trackers are opto-electronic sensors used onboard of satellites for the autonomous inertial attitude determination. During the last years, star trackers became more and more important in the field of the attitude and orbit control system (AOCS) sensors. High performance star trackers are based up today on charge coupled device (CCD) optical camera heads. The Jena-Optronik GmbH is active in the field of opto-electronic sensors like star trackers since the early 80-ties. Today, with the product family ASTRO5, ASTRO10 and ASTRO15, all marked segments like earth observation, scientific applications and geo-telecom are supplied to European and Overseas customers. A new generation of star trackers can be designed based on the APS detector technical features. The measurement performance of the current CCD based star trackers can be maintained, the star tracker functionality, reliability and robustness can be increased while the unit costs are saved.
Membrane Based Thermal Control Development
NASA Technical Reports Server (NTRS)
Murdoch, Karen
1997-01-01
The investigation of the feasibility of using a membrane device as a water boiler for thermal control is reported. The membrane device permits water vapor to escape to the vacuum of space but prevents the loss of liquid water. The vaporization of the water provides cooling to the water loop. This type of cooling device would have application for various types of short duration cooling needs where expenditure of water is allowed and a low pressure source is available such as in space or on a planet's surface. A variety of membrane samples, both hydrophilic and hydrophobic, were purchased to test for this thermal control application. An initial screening test determined if the membrane could pose a sufficient barrier to maintain water against vacuum. Further testing compared the heat transfer performance of those membranes that passed the screening test.
Current Protocols in Protein Science
Huynh, Kathy
2015-01-01
The purification of recombinant proteins for biochemical assays and structural studies is time-consuming and presents inherent difficulties that depend on the optimization of protein stability. The use of dyes to monitor thermal denaturation of proteins with sensitive fluorescence detection enables the rapid and inexpensive determination of protein stability using real-time PCR instruments. By screening a wide range of solution conditions and additives in 96-well format, the thermal shift assay easily identifies conditions that significantly enhance the stability of recombinant proteins. The same approach can be used as a low cost, initial screen to discover new protein:ligand interactions by capitalizing on increases in protein stability that typically occur upon ligand binding. This unit presents a methodological workflow for the small-scale, high-throughout thermal denaturation of recombinant proteins in the presence of SYPRO Orange dye. PMID:25640896
Exploratory screening tests of several alloys and coatings for automobile thermal reactors
NASA Technical Reports Server (NTRS)
Oldrieve, R. E.
1971-01-01
A total of 23 materials (including uncoated ferritic and austenitic iron-base alloys, uncoated nickel and cobalt-base superalloys, and several different coatings on AISI 304 stainless steel) were screened as test coupons on a rack in an automobile thermal reactor. Test exposures were generally 51 hours including 142 thermal cycles of 10 minutes at 1010 + or - 30 C test coupon temperature and 7-minutes cool-down to about 510 C. Materials that exhibited corrosion resistance better than that of Hastelloy X include: a ferritic iron alloy with 6 weight percent aluminum; three nickel-base superalloys; two diffused-aluminum coatings on AISI 304; and a Ni-Cr slurry-sprayed coating on AISI 304. Preliminary comparison is made on the performance of the directly impinged coupons and a reactor core of the same material.
Alley, Stephanie; Schoeppe, Stephanie; Guertler, Diana; Jennings, Cally; Vandelanotte, Corneel
2016-01-01
Objectives Pedometers are an effective self-monitoring tool to increase users' physical activity. However, a range of advanced trackers that measure physical activity 24 hours per day have emerged (eg, Fitbit). The current study aims to determine people's current use, interest and preferences for advanced trackers. Design and participants A cross-sectional national telephone survey was conducted in Australia with 1349 respondents. Outcome measures Regression analyses were used to determine whether tracker interest and use, and use of advanced trackers over pedometers is a function of demographics. Preferences for tracker features and reasons for not wanting to wear a tracker are also presented. Results Over one-third of participants (35%) had used a tracker, and 16% are interested in using one. Multinomial regression (n=1257) revealed that the use of trackers was lower in males (OR=0.48, 95% CI 0.36 to 0.65), non-working participants (OR=0.43, 95% CI 0.30 to 0.61), participants with lower education (OR=0.52, 95% CI 0.38 to 0.72) and inactive participants (OR=0.52, 95% CI 0.39 to 0.70). Interest in using a tracker was higher in younger participants (OR=1.73, 95% CI 1.15 to 2.58). The most frequently used tracker was a pedometer (59%). Logistic regression (n=445) revealed that use of advanced trackers compared with pedometers was higher in males (OR=1.67, 95% CI 1.01 to 2.79) and younger participants (OR=2.96, 95% CI 1.71 to 5.13), and lower in inactive participants (OR=0.35, 95% CI 0.19 to 0.63). Over half of current or interested tracker users (53%) prefer to wear it on their wrist, 31% considered counting steps the most important function and 30% regarded accuracy as the most important characteristic. The main reasons for not wanting to use a tracker were, ‘I don't think it would help me’ (39%), and ‘I don't want to increase my activity’ (47%). Conclusions Activity trackers are a promising tool to engage people in self-monitoring a physical activity. Trackers used in physical activity interventions should align with the preferences of target groups, and should be able to be worn on the wrist, measure steps and be accurate. PMID:27388359
Small star trackers for modern space vehicles
NASA Astrophysics Data System (ADS)
Kouzmin, Vladimir; Jushkov, Vladimir; Zaikin, Vladimir
2017-11-01
Based on experience of many years creation of spacecrafts' star trackers with diversified detectors (from the first star trackers of 60's to tens versions of star trackers in the following years), using technological achievements in the field of optics and electronics the NPP "Geofizika-Cosmos" has provided celestial orientation for all the space vehicles created in Russia and now has developed a series of new star trackers with CCD matrix and special processors, which are able to meet needs in celestial orientation of the modern spacecrafts for the nearest 10-15 years. In the given article the main characteristics and description of some star trackers' versions are presented. The star trackers have various levels of technical characteristics and use both combined (Russian and foreign) procurement parts, and only national (Russian) procurement parts for the main units.
Thermal Dispersion Within a Porous Medium Near a Solid Wall
NASA Technical Reports Server (NTRS)
Simon, T.; McFadden, G.; Ibrahim, M.
2006-01-01
The regenerator is a key component to Stirling cycle machine efficiency. Typical regenerators are of sintered fine wires or layers of fine-wire screens. Such porous materials are contained within solid-waH casings. Thermal energy exchange between the regenerator and the casing is important to cycle performance for the matrix and casing would not have the same axial temperature profile in an actual machine. Exchange from one to the other may allow shunting of thermal energy, reducing cycle efficiency. In this paper, temperature profiles within the near-wall region of the matrix are measured and thermal energy transport, termed thermal dispersion, is inferred. The data show how the wall affects thermal transport. Transport normal to the mean flow direction is by conduction within the solid and fluid and by advective transport within the matrix. In the near-wall region, both may be interrupted from their normal in-core pattern. Solid conduction paths are broken and scales of advective transport are damped. An equation is presented which describes this change for a wire screen mesh. The near-wall layer typically acts as an insulating layer. This should be considered in design or analysis. Effective thermal conductivity within the core is uniform. In-core transverse thermal effective conductivity values are compared to direct and indirect measurements reported elsewhere and to 3D numerical simulation results, computed previously and reported elsewhere. The 3-D CFD model is composed of six cylinders in cross flow, staggered in arrangement to match the dimensions and porosity of the matrix used in the experiments. The commercial code FLUENT is used to obtain the flow and thermal fields. The thermal dispersion and effective thermal conductivities for the matrix are computed from the results.
NASA Astrophysics Data System (ADS)
Herceg, M.; Jørgensen, P. S.; Jørgensen, J. L.
2017-08-01
Launched into orbit on November 22, 2013, the Swarm constellation of three satellites precisely measures magnetic signal of the Earth. To ensure the high accuracy of magnetic observation by vector magnetometer (VFM), its inertial attitude is precisely determined by μASC (micro Advanced Stellar Compass). Each of the three Swarm satellites is equipped with three μASC Camera Head Units (CHU) mounted on a common optical bench (OB), which has a purpose of transference of the attitude from the star trackers to the magnetometer measurements. Although substantial pre-launch analyses were made to maximize thermal and mechanical stability of the OB, significant signal with thermal signature is discovered when comparing relative attitude between the three CHU's (Inter Boresight Angle, IBA). These misalignments between CHU's, and consequently geomagnetic reference frame, are found to be correlated with the period of angle between Swarm orbital plane and the Sun (ca. 267 days), which suggests sensitivity of optical bench system on temperature variation. In this paper, we investigate the propagation of thermal effects into the μASC attitude observations and demonstrate how thermally induced attitude variation can be predicted and corrected in the Swarm data processing. The results after applying thermal corrections show decrease in IBA RMS from 6.41 to 2.58″. The model significantly improves attitude determination which, after correction, meets the requirements of Swarm satellite mission. This study demonstrates the importance of the OB pre-launch analysis to ensure minimum thermal gradient on satellite optical system and therefore maximum attitude accuracy.
Thermal imaging to detect physiological indicators of stress in humans
NASA Astrophysics Data System (ADS)
Cross, Carl B.; Skipper, Julie A.; Petkie, Douglas T.
2013-05-01
Real-time, stand-off sensing of human subjects to detect emotional state would be valuable in many defense, security and medical scenarios. We are developing a multimodal sensor platform that incorporates high-resolution electro-optical and mid-wave infrared (MWIR) cameras and a millimeter-wave radar system to identify individuals who are psychologically stressed. Recent experiments have aimed to: 1) assess responses to physical versus psychological stressors; 2) examine the impact of topical skin products on thermal signatures; and 3) evaluate the fidelity of vital signs extracted from thermal imagery and radar signatures. Registered image and sensor data were collected as subjects (n=32) performed mental and physical tasks. In each image, the face was segmented into 29 non-overlapping segments based on fiducial points automatically output by our facial feature tracker. Image features were defined that facilitated discrimination between psychological and physical stress states. To test the ability to intentionally mask thermal responses indicative of anxiety or fear, subjects applied one of four topical skin products to one half of their face before performing tasks. Finally, we evaluated the performance of two non-contact techniques to detect respiration and heart rate: chest displacement extracted from the radar signal and temperature fluctuations at the nose tip and regions near superficial arteries to detect respiration and heart rates, respectively, extracted from the MWIR imagery. Our results are very satisfactory: classification of physical versus psychological stressors is repeatedly greater than 90%, thermal masking was almost always ineffective, and accurate heart and respiration rates are detectable in both thermal and radar signatures.
NASA Astrophysics Data System (ADS)
Mongeon, R. J.
1984-11-01
The beam of a laser radar is moved over the field of view by means of a pair of scanner/trackers arranged in cascade along the laser beam. One of the scanner/trackers operates at high speed, with high resolution and a wide field and is located in the demagnified portion of the laser beam. The two scanner/trackers complement each other to achieve high speed, high resolution scanning as well as tracking of moving targets. A beam steering telescope for an airborne laser radar which incorporates the novel dual mode scanner/tracker is also shown. The other scanner/tracker operates at low speed with low resolution and a wide field and is located in the magnified portion of the laser beam.
Use of unbalanced laminates as a screening method for microcracking
NASA Technical Reports Server (NTRS)
Papadopoulos, Demetrios S.; Bowles, Kenneth J.
1990-01-01
State-of-the-art, high temperature polyimide matrix composites, reinforced with continuous graphite fibers are known to be susceptible to intraply cracking when thermally cycled over their useful service temperature range. It is believed that the transply cracking, in part, results from residual stresses caused by differences in coefficients of thermal expansion (CTE) between the polymer matrix and the reinforcement. Thermal cycling tests to investigate this phenomenon involve expensive time and energy consuming programs which are not economically feasible for use as a part of a materials screening process. As an alternative to thermal cycling studies, a study of unbalanced crossply graphite fiber reinforcement composites was conducted to assess the effect of the composite ply layup and surface condition on the residual stresses that remain after the processing of these materials. The residual stresses were assessed by measuring the radii of curvature of the types of laminates that were studied. The temperature at which stress-free conditions existed were determined and a dye penetrant method was used to observe surface damage resulting from excessive residual stress buildup. These results are compared with some published results of thermal cycling tests that were previously conducted on balanced polyimide composites.
A Novel Performance Evaluation Methodology for Single-Target Trackers.
Kristan, Matej; Matas, Jiri; Leonardis, Ales; Vojir, Tomas; Pflugfelder, Roman; Fernandez, Gustavo; Nebehay, Georg; Porikli, Fatih; Cehovin, Luka
2016-11-01
This paper addresses the problem of single-target tracker performance evaluation. We consider the performance measures, the dataset and the evaluation system to be the most important components of tracker evaluation and propose requirements for each of them. The requirements are the basis of a new evaluation methodology that aims at a simple and easily interpretable tracker comparison. The ranking-based methodology addresses tracker equivalence in terms of statistical significance and practical differences. A fully-annotated dataset with per-frame annotations with several visual attributes is introduced. The diversity of its visual properties is maximized in a novel way by clustering a large number of videos according to their visual attributes. This makes it the most sophistically constructed and annotated dataset to date. A multi-platform evaluation system allowing easy integration of third-party trackers is presented as well. The proposed evaluation methodology was tested on the VOT2014 challenge on the new dataset and 38 trackers, making it the largest benchmark to date. Most of the tested trackers are indeed state-of-the-art since they outperform the standard baselines, resulting in a highly-challenging benchmark. An exhaustive analysis of the dataset from the perspective of tracking difficulty is carried out. To facilitate tracker comparison a new performance visualization technique is proposed.
Wellbeing in the Making: Peoples' Experiences with Wearable Activity Trackers.
Karapanos, Evangelos; Gouveia, Rúben; Hassenzahl, Marc; Forlizzi, Jodi
Wearable activity trackers have become a viable business opportunity. Nevertheless, research has raised concerns over their potentially detrimental effects on wellbeing. For example, a recent study found that while counting steps with a pedometer increased steps taken throughout the day, at the same time it decreased the enjoyment people derived from walking. This poses a serious threat to the incorporation of healthy routines into everyday life. Most studies aim at proving the effectiveness of activity trackers. In contrast, a wellbeing-oriented perspective calls for a deeper understanding of how trackers create and mediate meaningful experiences in everyday life. We present a study of real life experiences with three wearable activity trackers: Fitbit , Jawbone Up and Nike + Fuelband . Using need fulfillment as a theoretical lens, we study recent, memorable experiences submitted by 133 users of activity trackers. We reveal a two-dimensional structure of users' experience driven by the needs of physical thriving or relatedness. Our qualitative findings further show a nuanced picture of the adoption of activity trackers and their impact on wellbeing. For instance, while reflection about own exercising practices lost its relevance over time, users continued to wear the tracker to document and collect their runs. More than just supporting behavioral change, we find trackers to provide multiple psychological benefits. For instance, they enhance feelings of autonomy as people gain more control about their exercising regime. Others experience relatedness, when family members purchase a tracker for relatives and join them in their efforts towards a better, healthier self. The study highlights that activity trackers can be more than "tools" to change behavior. Through incorporation in daily life, they offer new social experiences, new ways of boosting our self-esteem and getting closer to our ideal selves.
2017-01-01
Background As commercially available activity trackers are being utilized in clinical trials, the research community remains uncertain about reliability of the trackers, particularly in studies that involve walking aids and low-intensity activities. While these trackers have been tested for reliability during walking and running activities, there has been limited research on validating them during low-intensity activities and walking with assistive tools. Objective The aim of this study was to (1) determine the accuracy of 3 Fitbit devices (ie, Zip, One, and Flex) at different wearing positions (ie, pants pocket, chest, and wrist) during walking at 3 different speeds, 2.5, 5, and 8 km/h, performed by healthy adults on a treadmill; (2) determine the accuracy of the mentioned trackers worn at different sites during activities of daily living; and (3) examine whether intensity of physical activity (PA) impacts the choice of optimal wearing site of the tracker. Methods We recruited 15 healthy young adults to perform 6 PAs while wearing 3 Fitbit devices (ie, Zip, One, and Flex) on their chest, pants pocket, and wrist. The activities include walking at 2.5, 5, and 8 km/h, pushing a shopping cart, walking with aid of a walker, and eating while sitting. We compared the number of steps counted by each tracker with gold standard numbers. We performed multiple statistical analyses to compute descriptive statistics (ie, ANOVA test), intraclass correlation coefficient (ICC), mean absolute error rate, and correlation by comparing the tracker-recorded data with that of the gold standard. Results All the 3 trackers demonstrated good-to-excellent (ICC>0.75) correlation with the gold standard step counts during treadmill experiments. The correlation was poor (ICC<0.60), and the error rate was significantly higher in walker experiment compared to other activities. There was no significant difference between the trackers and the gold standard in the shopping cart experiment. The wrist worn tracker, Flex, counted several steps when eating (P<.01). The chest tracker was identified as the most promising site to capture steps in more intense activities, while the wrist was the optimal wearing site in less intense activities. Conclusions This feasibility study focused on 6 PAs and demonstrated that Fitbit trackers were most accurate when walking on a treadmill and least accurate during walking with a walking aid and for low-intensity activities. This may suggest excluding participants with assistive devices from studies that focus on PA interventions using commercially available trackers. This study also indicates that the wearing site of the tracker is an important factor impacting the accuracy performance. A larger scale study with a more diverse population, various activity tracker vendors, and a larger activity set are warranted to generalize our results. PMID:28801304
NASA Technical Reports Server (NTRS)
Yen, Judy C. H.; Tomsik, Thomas M.
2004-01-01
This paper describes the results of a series of catalyst screening tests conducted with Jet-A fuel under auto-thermal reforming (ATR) process conditions at the research laboratories of SOFCo-EFS Holdings LLC under Glenn Research Center Contract. The primary objective is to identify best available catalysts for future testing at the NASA GRC 10-kW(sub e) reformer test facility. The new GRC reformer-injector test rig construction is due to complete by March 2004. Six commercially available monolithic catalyst materials were initially selected by the NASA/SOFCo team for evaluation and bench scale screening in an existing 0.05 kW(sub e) microreactor test apparatus. The catalyst screening tests performed lasted 70 to 100 hours in duration in order to allow comparison between the different samples over a defined range of ATR process conditions. Aging tests were subsequently performed with the top two ranked catalysts as a more representative evaluation of performance in a commercial aerospace application. The two catalyst aging tests conducted lasting for approximately 600 hours and 1000 hours, respectively.
NASA Astrophysics Data System (ADS)
Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.
2011-01-01
In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.
Deformation mechanism of the Cryostat in the CADS Injector II
NASA Astrophysics Data System (ADS)
Yuan, Jiandong; Zhang, Bin; Wan, Yuqin; Sun, Guozhen; Bai, Feng; Zhang, Juihui; He, Yuan
2018-01-01
Thermal contraction and expansion of the Cryostat will affect its reliability and stability. To optimize and upgrade the Cryostat, we analyzed the heat transfer in a cryo-vacuum environment from the theoretical point first. The simulation of cryo-vacuum deformation based on a finite element method was implemented respectively. The completed measurement based on a Laser Tracker and a Micro Alignment Telescope was conducted to verify its correctness. The monitored deformations were consistent with the simulated ones. After the predictable deformations in vertical direction have been compensated, the superconducting solenoids and Half Wave Resonator cavities approached the ideal "zero" position under liquid helium conditions. These guaranteed the success of 25 MeV@170 uA continuous wave protons of Chinese accelerator driven subcritical system Injector II. By correlating the vacuum and cryo-deformation, we have demonstrated that the complete deformation was the superposition effect of the atmospheric pressure, gravity and thermal stress during both the process of cooling down and warming up. The results will benefit to an optimization for future Cryostat's design.
Tuning the Solar Dynamics Observatory Onboard Kalman Filter
NASA Technical Reports Server (NTRS)
Halverson, Julie Kay; Harman, Rick; Carpenter, Russell; Poland, Devin
2017-01-01
The Solar Dynamics Observatory (SDO) was launched in 2010. SDO is a sun pointing semi-autonomous spacecraft in a geosynchronous orbit that allows nearly continuous observations of the sun. SDO is equipped with coarse sun sensors, two star trackers, a digital sun sensor, and three two-axis inertial reference units (IRU). The IRUs are temperature sensitive and were designed to operate in a stable thermal environment. Due to battery degradation concerns the IRU heaters were not used on SDO and the onboard filter was tuned to accommodate the noisier IRU data. Since launch currents have increased on two IRUs, one had to eventually be powered off. Recent ground tests on a battery similar to SDO indicated the heaters would have negligible impact on battery degradation, so in 2016 a decision was made to turn the heaters on. This paper presents the analysis and results of updating the filter tuning parameters onboard SDO with the IRUs now operating in their intended thermal environment.
Autonomous Aerobraking: Thermal Analysis and Response Surface Development
NASA Technical Reports Server (NTRS)
Dec, John A.; Thornblom, Mark N.
2011-01-01
A high-fidelity thermal model of the Mars Reconnaissance Orbiter was developed for use in an autonomous aerobraking simulation study. Response surface equations were derived from the high-fidelity thermal model and integrated into the autonomous aerobraking simulation software. The high-fidelity thermal model was developed using the Thermal Desktop software and used in all phases of the analysis. The use of Thermal Desktop exclusively, represented a change from previously developed aerobraking thermal analysis methodologies. Comparisons were made between the Thermal Desktop solutions and those developed for the previous aerobraking thermal analyses performed on the Mars Reconnaissance Orbiter during aerobraking operations. A variable sensitivity screening study was performed to reduce the number of variables carried in the response surface equations. Thermal analysis and response surface equation development were performed for autonomous aerobraking missions at Mars and Venus.
NASA Technical Reports Server (NTRS)
1974-01-01
The feasibility is evaluated of an evolutionary development for use of a single-axis gimbal star tracker from prior two-axis gimbal star tracker based system applications. Detailed evaluation of the star tracker gimbal encoder is considered. A brief system description is given including the aspects of tracker evolution and encoder evaluation. System analysis includes evaluation of star availability and mounting constraints for the geosynchronous orbit application, and a covariance simulation analysis to evaluate performance potential. Star availability and covariance analysis digital computer programs are included.
High-Tc thermal bridges for space-borne cryogenic infrared detectors
NASA Technical Reports Server (NTRS)
Wise, S. A.; Buckley, J. D.; Nolt, I.; Hooker, M. W.; Haertling, G. H.; Selim, R.; Caton, R.; Buoncristiani, A. M.
1993-01-01
The potential for using high-temperature superconductive elements, screen-printed onto ceramic substrates, as thermal bridges to replace the currently employed manganin wires is studied at NASA-LaRC. Substrate selection is considered to be the most critical parameter in device production. Due to the glass-like thermal behavior of yttria-stabilized-zirconia (YSZ) and fused silica substrates, these materials are found to reduce the heat load significantly. The estimated thermal savings for superconductive leads printed onto YSZ or fused silica substrates range from 6 to 14 percent.
Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module
NASA Technical Reports Server (NTRS)
Nowak, Maria; Crane, Allen; Davila, Pam; Eichhorn, William; Gill, James; Herrera, Acey; Hill, Michael; Hylan, Jason; Jetten, Mark; Marsh, James;
2007-01-01
The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.
Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials
NASA Technical Reports Server (NTRS)
Riccio, Joe; Milhoan, Jim D.
2010-01-01
Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.
NASA Astrophysics Data System (ADS)
Bateman, Robert; Harris, Adam; Lee, Linda; Howle, Christopher R.; Ackermann, Sarah L. G.
2016-05-01
The paper will review the feasibility of adapting the Modified Transient Plane Source (MTPS) method as a screening tool for early-detection of explosives and hazardous materials. Materials can be distinguished from others based on their inherent thermal properties (e.g. thermal effusivity) in testing through different types of barrier materials. A complimentary advantage to this technique relative to other traditional detection technologies is that it can penetrate reflective barrier materials, such as aluminum, easily. A strong proof-of-principle is presented on application of the MTPS transient thermal property measuring in the early-screening of liquid explosives. The work demonstrates a significant sensitivity to distinguishing a wide range of fluids based on their thermal properties through a barrier material. The work covers various complicating factors to the longer-term adoption of such a method including the impact of carbonization and viscosity. While some technical challenges remain, the technique offers significant advantages in complimenting existing detection methods in being able to penetrate reflective metal containers (e.g. aluminum soft drinkscans) with ease.
NASA Astrophysics Data System (ADS)
Wu, Zhangming; Li, Hao
2017-11-01
This paper proposes a novel adaptive sun tracker which is constructed by hybrid unsymmetric composite laminates. The adaptive sun tracker could be applied on spacecraft solar panels to increase their energy efficiency through decreasing the inclined angle between the sunlight and the solar panel normal. The sun tracker possesses a large rotation freedom and its rotation angle depends on the laminate temperature, which is affected by the light condition in the orbit. Both analytical model and finite element model (FEM) are developed for the sun tracker to predict its rotation angle in different light conditions. In this work, the light condition of the geosynchronous orbit on winter solstice is considered in the numerical prediction of the temperatures of the hybrid laminates. The final inclined angle between the sunlight and the solar panel normal during a solar day is computed using the finite element model. Parametric study of the adaptive sun tracker is conducted to improve its capacity and effectiveness of sun tracking. The improved adaptive sun tracker is lightweight and has a state-of-the-art design. In addition, the adaptive sun tracker does not consume any power of the solar panel, since it has no electrical driving devices. The proposed adaptive sun tracker provides a potential alternative to replace the traditional sophisticated electrical driving mechanisms for spacecraft solar panels.
Validation of an Electronic System for Recording Medical Student Patient Encounters
Nkoy, Flory L.; Petersen, Sarah; Matheny Antommaria, Armand H.; Maloney, Christopher G.
2008-01-01
The Liaison Committee for Medical Education requires monitoring of the students’ clinical experiences. Student logs, typically used for this purpose, have a number of limitations. We used an electronic system called Patient Tracker to passively generate student encounter data. The data contained in Patient Tracker was compared to the information reported on student logs and data abstracted from the patients’ charts. Patient Tracker identified 30% more encounters than the student logs. Compared to the student logs, Patient Tracker contained a higher average number of diagnoses per encounter (2.28 vs. 1.03, p<0.01). The diagnostic data contained in Patient Tracker was also more accurate under 4 different definitions of accuracy. Only 1.3% (9/677) of diagnoses in Patient Tracker vs. 16.9% (102/601) diagnoses in the logs could not be validated in patients’ charts (p<0.01). Patient Tracker is a more effective and accurate tool for documenting student clinical encounters than the conventional student logs. PMID:18999155
Novel approach to improve the attitude update rate of a star tracker.
Zhang, Shuo; Xing, Fei; Sun, Ting; You, Zheng; Wei, Minsong
2018-03-05
The star tracker is widely used in attitude control systems of spacecraft for attitude measurement. The attitude update rate of a star tracker is important to guarantee the attitude control performance. In this paper, we propose a novel approach to improve the attitude update rate of a star tracker. The electronic Rolling Shutter (RS) imaging mode of the complementary metal-oxide semiconductor (CMOS) image sensor in the star tracker is applied to acquire star images in which the star spots are exposed with row-to-row time offsets, thereby reflecting the rotation of star tracker at different times. The attitude estimation method with a single star spot is developed to realize the multiple attitude updates by a star image, so as to reach a high update rate. The simulation and experiment are performed to verify the proposed approaches. The test results demonstrate that the proposed approach is effective and the attitude update rate of a star tracker is increased significantly.
Alinia, Parastoo; Cain, Chris; Fallahzadeh, Ramin; Shahrokni, Armin; Cook, Diane; Ghasemzadeh, Hassan
2017-08-11
As commercially available activity trackers are being utilized in clinical trials, the research community remains uncertain about reliability of the trackers, particularly in studies that involve walking aids and low-intensity activities. While these trackers have been tested for reliability during walking and running activities, there has been limited research on validating them during low-intensity activities and walking with assistive tools. The aim of this study was to (1) determine the accuracy of 3 Fitbit devices (ie, Zip, One, and Flex) at different wearing positions (ie, pants pocket, chest, and wrist) during walking at 3 different speeds, 2.5, 5, and 8 km/h, performed by healthy adults on a treadmill; (2) determine the accuracy of the mentioned trackers worn at different sites during activities of daily living; and (3) examine whether intensity of physical activity (PA) impacts the choice of optimal wearing site of the tracker. We recruited 15 healthy young adults to perform 6 PAs while wearing 3 Fitbit devices (ie, Zip, One, and Flex) on their chest, pants pocket, and wrist. The activities include walking at 2.5, 5, and 8 km/h, pushing a shopping cart, walking with aid of a walker, and eating while sitting. We compared the number of steps counted by each tracker with gold standard numbers. We performed multiple statistical analyses to compute descriptive statistics (ie, ANOVA test), intraclass correlation coefficient (ICC), mean absolute error rate, and correlation by comparing the tracker-recorded data with that of the gold standard. All the 3 trackers demonstrated good-to-excellent (ICC>0.75) correlation with the gold standard step counts during treadmill experiments. The correlation was poor (ICC<0.60), and the error rate was significantly higher in walker experiment compared to other activities. There was no significant difference between the trackers and the gold standard in the shopping cart experiment. The wrist worn tracker, Flex, counted several steps when eating (P<.01). The chest tracker was identified as the most promising site to capture steps in more intense activities, while the wrist was the optimal wearing site in less intense activities. This feasibility study focused on 6 PAs and demonstrated that Fitbit trackers were most accurate when walking on a treadmill and least accurate during walking with a walking aid and for low-intensity activities. This may suggest excluding participants with assistive devices from studies that focus on PA interventions using commercially available trackers. This study also indicates that the wearing site of the tracker is an important factor impacting the accuracy performance. A larger scale study with a more diverse population, various activity tracker vendors, and a larger activity set are warranted to generalize our results. ©Parastoo Alinia, Chris Cain, Ramin Fallahzadeh, Armin Shahrokni, Diane Cook, Hassan Ghasemzadeh. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 11.08.2017.
An analysis of automatic human detection and tracking
NASA Astrophysics Data System (ADS)
Demuth, Philipe R.; Cosmo, Daniel L.; Ciarelli, Patrick M.
2015-12-01
This paper presents an automatic method to detect and follow people on video streams. This method uses two techniques to determine the initial position of the person at the beginning of the video file: one based on optical flow and the other one based on Histogram of Oriented Gradients (HOG). After defining the initial bounding box, tracking is done using four different trackers: Median Flow tracker, TLD tracker, Mean Shift tracker and a modified version of the Mean Shift tracker using HSV color space. The results of the methods presented in this paper are then compared at the end of the paper.
A multi-hypothesis tracker for clicking whales.
Baggenstoss, Paul M
2015-05-01
This paper describes a tracker specially designed to track clicking beaked whales using widely spaced bottom-mounted hydrophones, although it can be adapted to different species and sensors. The input to the tracker is a sequence of static localization solutions obtained using time difference of arrival information at widely spaced hydrophones. To effectively handle input localizations with high ambiguity, the tracker is based on multi-hypothesis tracker concepts, so it considers all potential association hypotheses and keeps a large number of potential tracks in memory. The method is demonstrated on actual data and shown to successfully track multiple beaked whales at depth.
Liu, Chao-Li; Hackley, Keith C.; Coleman, D.D.; Kruse, C.W.
1987-01-01
A method using stable isotope ratio analysis to monitor the reactivity of sulfur forms in coal during thermal and chemical desulfurization processes has been developed at the Illinois State Geological Survey. The method is based upon the fact that a significant difference exists in some coals between the 34S/32S ratios of the pyritic and organic sulfur. A screening method for determining the suitability of coal samples for use in isotope ratio analysis is described. Making these special coals available from coal sample programs would assist research groups in sorting out the complex sulfur chemistry which accompanies thermal and chemical processing of high sulfur coals. ?? 1987.
NASA Technical Reports Server (NTRS)
Oldrieve, R. E.
1971-01-01
Fourteen materials were evaluated in engine screening tests on full-size thermal reactors for automobile engine pollution control systems. Cyclic test-stand engine operation provided 2 hours at 1040 C and a 20-minute air-cool to 70 C each test cycle. Each reactor material was exposed to 83 cycles in 200 hours of engine testing. On the basis of resistance to oxidation and distortion, the best materials included two ferritic iron alloys (Ge 1541 and Armco 18S/R), several commercial oxidation-resistant coatings on AlSl 651 (19-9 DL), and possibly uncoated AISI 310. The best commercial coatings were Cr-Al, Ni-Cr, and a glass ceramic.
NASA flight electronics environmental stress screening survey
NASA Technical Reports Server (NTRS)
Marian, E. J. (Compiler)
1983-01-01
Data compiled by the Institute of Environmental Sciences were used to establish guidelines for identifying defective, abnormal, or marginal parts as well as manufacturing defects. These data are augmented with other available sources of similar information in conjunction with NASA centers' data and presented in a form that may be useful to all NASA centers in planning and developing effective environmental stress screens. Information relative to thermal and vibration screens as the most effective methods for surfacing latent failures in electronic equipment at the component level is considered.
NASA Technical Reports Server (NTRS)
1974-01-01
Attitude reference systems for use with the Earth Observatory Satellite (EOS) are described. The systems considered are fixed and gimbaled star trackers, star mappers, and digital sun sensors. Covariance analyses were performed to determine performance for the most promising candidate in low altitude and synchronous orbits. The performance of attitude estimators that employ gyroscopes which are periodically updated by a star sensor is established by a single axis covariance analysis. The other systems considered are: (1) the propulsion system design, (2) electric power and electrical integration, (3) thermal control, (4) ground data processing, and (5) the test plan and cost reduction aspects of observatory integration and test.
OAO-3 end of mission tests report
NASA Technical Reports Server (NTRS)
Kalil, F.; Kull, F. J.; Mcintosh, R.; Ollendorf, S.; Margolies, D. L.; Gemmell, J.; Tasevoli, C. M.; Polidan, R. S.; Kochevar, H.; Chapman, C.
1981-01-01
Twelve engineering type tests were performed on several subsystems and experiment(s) of the OAO 3 spacecraft near its end of mission. The systems tested include: Princeton experiment package (PEP), fine error system guidance, inertial reference unit, star trackers, heat pipes, thermal control coatings, command and data handling, solar array; batteries, and onboard processor/power boost regulator. Generally, the systems performed well for the 8 1/2 years life of OAO 3, although some degradation was noted in the sensitivity of PEP and in the absorptivity of the skin coatings. Battery life was prolonged during the life of the mission in large part by carefully monitoring the charge-discharge cycle with careful attention not to overcharge.
NASA Technical Reports Server (NTRS)
2002-01-01
Dimension Technologies Inc., developed a line of 2-D/3-D Liquid Crystal Display (LCD) screens, including a 15-inch model priced at consumer levels. DTI's family of flat panel LCD displays, called the Virtual Window(TM), provide real-time 3-D images without the use of glasses, head trackers, helmets, or other viewing aids. Most of the company initial 3-D display research was funded through NASA's Small Business Innovation Research (SBIR) program. The images on DTI's displays appear to leap off the screen and hang in space. The display accepts input from computers or stereo video sources, and can be switched from 3-D to full-resolution 2-D viewing with the push of a button. The Virtual Window displays have applications in data visualization, medicine, architecture, business, real estate, entertainment, and other research, design, military, and consumer applications. Displays are currently used for computer games, protein analysis, and surgical imaging. The technology greatly benefits the medical field, as surgical simulators are helping to increase the skills of surgical residents. Virtual Window(TM) is a trademark of Dimension Technologies Inc.
Continual Screening of Patients Using mHealth: The Rolling Score Concept Applied to Sleep Medicine.
Zluga, Claudio; Modre-Osprian, Robert; Kastner, Peter; Schreier, Günter
2016-01-01
Continual monitoring of patients utilizing mHealth-based telemonitoring applications are more and more used for individual management of patients. A new approach in risk assessment called Rolling Score Concept uses standardized questionnaires for continual scoring of individuals' health state through electronic patient reported outcome (ePRO). Using self-rated questionnaires and adding a specific Time Schedule to each question result in a movement of the questionnaires' scores over time, the Rolling Score. A text-processing pipeline was implemented with KNIME analytics platform to extract a Score Mapping Rule Set for three standardized screening questionnaires in the field of sleep medicine. A feasibility study was performed in 10 healthy volunteers equipped with a mHealth application on a smartphone and a sleep tracker. Results show that the proposed Rolling Score Concept is feasible and deviations of scores are in a reasonable range (< 7%), sustaining the new approach. However, further studies are required for verification. In addition, parameter quantification could avoid incorrect subjective evaluation by substitution of questions with sensor data.
NASA Astrophysics Data System (ADS)
Arya, A.; Sarafraz, M. M.; Shahmiri, S.; Madani, S. A. H.; Nikkhah, V.; Nakhjavani, S. M.
2018-04-01
Experimental investigation on the thermal performance of a flat heat pipe working with carbon nanotube nanofluid is conducted. It is used for cooling a heater working at high heat flux conditions up to 190 kW/m2. The heat pipe is fabricated from aluminium and is equipped with rectangular fin for efficient cooling of condenser section. Inside the heat pipe, a screen mesh was inserted as a wick structure to facilitate the capillary action of working fluid. Influence of different operating parameters such as heat flux, mass concentration of carbon nanotubes and filling ratio of working fluid on thermal performance of heat pipe and its thermal resistance are investigated. Results showed that with an increase in heat flux, the heat transfer coefficient in evaporator section of the heat pipe increases. For filling ratio, however, there is an optimum value, which was 0.8 for the test heat pipe. In addition, CNT/water enhanced the heat transfer coefficient up to 40% over the deionized water. Carbon nanotubes intensified the thermal performance of wick structure by creating a fouling layer on screen mesh structure, which changes the contact angle of liquid with the surface, intensifying the capillary forces.
Development of Thermal Bridging Factors for Use in Energy Models
2015-06-20
assemblies. 5.2.2 Drainage : Drained systems Drained (Figure 5-6) and screened enclosures assume some rainwater will penetrate the outer surface...38 5.2.2 Drainage : Drained systems ...layer (e.g., drainage plane and gap or waterproofing) 2. Airflow control layer (e.g., an air barrier system ) 3. Thermal control layer (e.g., insulation
Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay.
Liu, Wen-Wen; Zhu, Ying; Fang, Qun
2017-06-20
There is a great demand to measure protein-ligand interactions in rapid and low cost way. Here, we developed a microfluidic droplet-based thermal shift assay (dTSA) system for high-throughput screening of small-molecule protein ligands. The system is composed of a nanoliter droplet array chip, a microfluidic droplet robot, and a real-time fluorescence detection system. Total 324 assays could be performed in parallel in a single chip with an 18 × 18 droplet array. The consumption of dTSA for each protein or ligand sample was only 5 nL (femtomole scale), which is significantly reduced by over 3 orders of magnitude compared with those in 96- or 384-well plate-based systems. We also observed the implementation of TSA in nanoliter droplet format could substantially improve assay precision with relative standard deviation (RSD) of 0.2% (n = 50), which can be ascribed to the enhanced thermal conduction in small volume reactors. The dTSA system was optimized by studying the effect of droplet volumes, as well as protein and fluorescent dye (SYPRO Orange) concentrations. To demonstrate its potential in drug discovery, we applied the dTSA system in screening inhibitors of human thrombin with a commercial library containing 100 different small molecule compounds, and two inhibitors were successfully identified and confirmed.
Hughey, Justin R; Keen, Justin M; Brough, Chris; Saeger, Sophie; McGinity, James W
2011-10-31
Poorly water-soluble drug substances that exhibit high melting points are often difficult to successfully process by fusion-based techniques. The purpose of this study was to identify a suitable polymer system for meloxicam (MLX), a high melting point class II BCS compound, and investigate thermal processing techniques for the preparation of chemically stable single phase solid dispersions. Thermal and solution based screening techniques were utilized to screen hydrophilic polymers suitable for immediate release formulations. Results of the screening studies demonstrated that Soluplus(®)(SOL) provided the highest degree of miscibility and solubility enhancement. A hot-melt extrusion feasibility study demonstrated that high temperatures and extended residence times were required in order to render compositions amorphous, causing significant degradation of MLX. A design of experiments (DOE) was conducted on the KinetiSol(®) Dispersing (KSD) process to evaluate the effect of processing conditions on the chemical stability and amorphous character of MLX. The study demonstrated that ejection temperature significantly impacted MLX stability. All samples prepared by KSD were substantially amorphous. Dissolution analysis of the KSD processed solid dispersions showed increased dissolution rates and extent of supersaturation over the marketed generic MLX tablets. Copyright © 2011 Elsevier B.V. All rights reserved.
Correlation tracking study for meter-class solar telescope on space shuttle. [solar granulation
NASA Technical Reports Server (NTRS)
Smithson, R. C.; Tarbell, T. D.
1977-01-01
The theory and expected performance level of correlation trackers used to control the pointing of a solar telescope in space using white light granulation as a target were studied. Three specific trackers were modeled and their performance levels predicted for telescopes of various apertures. The performance of the computer model trackers on computer enhanced granulation photographs was evaluated. Parametric equations for predicting tracker performance are presented.
Low-Frequency Error Extraction and Compensation for Attitude Measurements from STECE Star Tracker.
Lai, Yuwang; Gu, Defeng; Liu, Junhong; Li, Wenping; Yi, Dongyun
2016-10-12
The low frequency errors (LFE) of star trackers are the most penalizing errors for high-accuracy satellite attitude determination. Two test star trackers- have been mounted on the Space Technology Experiment and Climate Exploration (STECE) satellite, a small satellite mission developed by China. To extract and compensate the LFE of the attitude measurements for the two test star trackers, a new approach, called Fourier analysis, combined with the Vondrak filter method (FAVF) is proposed in this paper. Firstly, the LFE of the two test star trackers' attitude measurements are analyzed and extracted by the FAVF method. The remarkable orbital reproducibility features are found in both of the two test star trackers' attitude measurements. Then, by using the reproducibility feature of the LFE, the two star trackers' LFE patterns are estimated effectively. Finally, based on the actual LFE pattern results, this paper presents a new LFE compensation strategy. The validity and effectiveness of the proposed LFE compensation algorithm is demonstrated by the significant improvement in the consistency between the two test star trackers. The root mean square (RMS) of the relative Euler angle residuals are reduced from [27.95'', 25.14'', 82.43''], 3σ to [16.12'', 15.89'', 53.27''], 3σ.
Infrared thermal imaging in medicine.
Ring, E F J; Ammer, K
2012-03-01
This review describes the features of modern infrared imaging technology and the standardization protocols for thermal imaging in medicine. The technique essentially uses naturally emitted infrared radiation from the skin surface. Recent studies have investigated the influence of equipment and the methods of image recording. The credibility and acceptance of thermal imaging in medicine is subject to critical use of the technology and proper understanding of thermal physiology. Finally, we review established and evolving medical applications for thermal imaging, including inflammatory diseases, complex regional pain syndrome and Raynaud's phenomenon. Recent interest in the potential applications for fever screening is described, and some other areas of medicine where some research papers have included thermal imaging as an assessment modality. In certain applications thermal imaging is shown to provide objective measurement of temperature changes that are clinically significant.
A formative evaluation of the SWITCH® obesity prevention program: print versus online programming.
Welk, Gregory J; Chen, Senlin; Nam, Yoon Ho; Weber, Tara E
2015-01-01
SWITCH® is an evidence-based childhood obesity prevention program that works through schools to impact parenting practices. The present study was designed as a formative evaluation to test whether an online version of SWITCH® would work equivalently as the established print version. Ten elementary schools were matched by socio-economic status and randomly assigned to receive either the print (n = 5) or online (n = 5) version. A total of 211 children from 22, 3(rd) grade classrooms were guided through the 4 month program by a team of program leaders working in cooperation with the classroom teachers. Children were tasked with completing weekly SWITCH® Trackers with their parents to monitor goal setting efforts in showing positive Do (≥60 minutes of moderate-to-vigorous physical activity), View (≤2 hours of screen time), and Chew (≥5 servings of fruits and vegetables) behaviors on each day. A total of 91 parents completed a brief survey to assess project-specific interactions with their child and the impact on their behaviors. The majority of parents (93.2%) reported satisfactory experiences with either the online or print SWITCH® program. The return rate for the SWITCH® Trackers was higher (42.5% ± 11%) from the print schools compared to the online schools (27.4% ± 10.9%). District program managers rated the level of teacher engagement in regards to program facilitation and the results showed a higher Trackers return rate in the highly engaged schools (38.5% ± 13.3%) than the lowly engaged schools (28.6 ± 11.9%). No significant differences were observed in parent/child interactions or reported behavior change (ps > .05) suggesting the equivalence in intervention effect for print and online versions of the SWITCH® program. The findings support the utility of the online SWITCH® platform but school-based modules are needed to facilitate broader school engagement by classroom teachers and PE teachers.
Technology transfer: Imaging tracker to robotic controller
NASA Technical Reports Server (NTRS)
Otaguro, M. S.; Kesler, L. O.; Land, Ken; Erwin, Harry; Rhoades, Don
1988-01-01
The transformation of an imaging tracker to a robotic controller is described. A multimode tracker was developed for fire and forget missile systems. The tracker locks on to target images within an acquisition window using multiple image tracking algorithms to provide guidance commands to missile control systems. This basic tracker technology is used with the addition of a ranging algorithm based on sizing a cooperative target to perform autonomous guidance and control of a platform for an Advanced Development Project on automation and robotics. A ranging tracker is required to provide the positioning necessary for robotic control. A simple functional demonstration of the feasibility of this approach was performed and described. More realistic demonstrations are under way at NASA-JSC. In particular, this modified tracker, or robotic controller, will be used to autonomously guide the Man Maneuvering Unit (MMU) to targets such as disabled astronauts or tools as part of the EVA Retriever efforts. It will also be used to control the orbiter's Remote Manipulator Systems (RMS) in autonomous approach and positioning demonstrations. These efforts will also be discussed.
Software and mathematical support of Kazakhstani star tracker
NASA Astrophysics Data System (ADS)
Akhmedov, D.; Yelubayev, S.; Ten, V.; Bopeyev, T.; Alipbayev, K.; Sukhenko, A.
2016-10-01
Currently the specialists of Kazakhstan have been developing the star tracker that is further planned to use on Kazakhstani satellites of various purposes. At the first stage it has been developed the experimental model of star tracker that has following characteristics: field of view 20°, update frequency 2 Hz, exclusion angle 40°, accuracy of attitude determination of optical axis/around optical axis 15/50 arcsec. Software and mathematical support are the most high technology parts of star tracker. The results of software and mathematical support development of experimental model of Kazakhstani star tracker are represented in this article. In particular, there are described the main mathematical models and algorithms that have been used as a basis for program units of preliminary image processing of starry sky, stars identification and star tracker attitude determination. The results of software and mathematical support testing with the help of program simulation complex using various configurations of defects including image sensor noises, point spread function modeling, optical system distortion up to 2% are presented. Analysis of testing results has shown that accuracy of attitude determination of star tracker is within the permissible range
Breadboard stellar tracker system test report, volume 1
NASA Technical Reports Server (NTRS)
Kollodge, J. C.; Hubbard, M. W.; Jain, S.; Schons, C. A.
1981-01-01
The performance of a star tracker equipped with a focal plane detector was evaluated. The CID board is an array of 256 x 256 pixels which are 20 x 20 micrometers in dimension. The tracker used for test was a breadboard tracker system developed by BASD. Unique acquisition and tracking algorithms are employed to enhance performance. A pattern recognition process is used to test for proper image spread function and to avoid false acquisition on noise. A very linear, high gain, interpixel transfer function is derived for interpolating star position. The lens used in the tracker has an EFL of 100 mm. The tracker has an FOV of 2.93 degrees resulting in a pixel angular subtense of 41.253 arc sec in each axis. The test procedure used for the program presented a star to the tracker in a circular pattern of positions; the pattern was formed by projecting a simulated star through a rotatable deviation wedge. Further tests determined readout noise, Noise Equivalent Displacement during track, and spatial noise during acquisition by taking related data and reducing it.
Optical System Error Analysis and Calibration Method of High-Accuracy Star Trackers
Sun, Ting; Xing, Fei; You, Zheng
2013-01-01
The star tracker is a high-accuracy attitude measurement device widely used in spacecraft. Its performance depends largely on the precision of the optical system parameters. Therefore, the analysis of the optical system parameter errors and a precise calibration model are crucial to the accuracy of the star tracker. Research in this field is relatively lacking a systematic and universal analysis up to now. This paper proposes in detail an approach for the synthetic error analysis of the star tracker, without the complicated theoretical derivation. This approach can determine the error propagation relationship of the star tracker, and can build intuitively and systematically an error model. The analysis results can be used as a foundation and a guide for the optical design, calibration, and compensation of the star tracker. A calibration experiment is designed and conducted. Excellent calibration results are achieved based on the calibration model. To summarize, the error analysis approach and the calibration method are proved to be adequate and precise, and could provide an important guarantee for the design, manufacture, and measurement of high-accuracy star trackers. PMID:23567527
Pedestrian Detection and Tracking from Low-Resolution Unmanned Aerial Vehicle Thermal Imagery
Ma, Yalong; Wu, Xinkai; Yu, Guizhen; Xu, Yongzheng; Wang, Yunpeng
2016-01-01
Driven by the prominent thermal signature of humans and following the growing availability of unmanned aerial vehicles (UAVs), more and more research efforts have been focusing on the detection and tracking of pedestrians using thermal infrared images recorded from UAVs. However, pedestrian detection and tracking from the thermal images obtained from UAVs pose many challenges due to the low-resolution of imagery, platform motion, image instability and the relatively small size of the objects. This research tackles these challenges by proposing a pedestrian detection and tracking system. A two-stage blob-based approach is first developed for pedestrian detection. This approach first extracts pedestrian blobs using the regional gradient feature and geometric constraints filtering and then classifies the detected blobs by using a linear Support Vector Machine (SVM) with a hybrid descriptor, which sophisticatedly combines Histogram of Oriented Gradient (HOG) and Discrete Cosine Transform (DCT) features in order to achieve accurate detection. This research further proposes an approach for pedestrian tracking. This approach employs the feature tracker with the update of detected pedestrian location to track pedestrian objects from the registered videos and extracts the motion trajectory data. The proposed detection and tracking approaches have been evaluated by multiple different datasets, and the results illustrate the effectiveness of the proposed methods. This research is expected to significantly benefit many transportation applications, such as the multimodal traffic performance measure, pedestrian behavior study and pedestrian-vehicle crash analysis. Future work will focus on using fused thermal and visual images to further improve the detection efficiency and effectiveness. PMID:27023564
Pedestrian Detection and Tracking from Low-Resolution Unmanned Aerial Vehicle Thermal Imagery.
Ma, Yalong; Wu, Xinkai; Yu, Guizhen; Xu, Yongzheng; Wang, Yunpeng
2016-03-26
Driven by the prominent thermal signature of humans and following the growing availability of unmanned aerial vehicles (UAVs), more and more research efforts have been focusing on the detection and tracking of pedestrians using thermal infrared images recorded from UAVs. However, pedestrian detection and tracking from the thermal images obtained from UAVs pose many challenges due to the low-resolution of imagery, platform motion, image instability and the relatively small size of the objects. This research tackles these challenges by proposing a pedestrian detection and tracking system. A two-stage blob-based approach is first developed for pedestrian detection. This approach first extracts pedestrian blobs using the regional gradient feature and geometric constraints filtering and then classifies the detected blobs by using a linear Support Vector Machine (SVM) with a hybrid descriptor, which sophisticatedly combines Histogram of Oriented Gradient (HOG) and Discrete Cosine Transform (DCT) features in order to achieve accurate detection. This research further proposes an approach for pedestrian tracking. This approach employs the feature tracker with the update of detected pedestrian location to track pedestrian objects from the registered videos and extracts the motion trajectory data. The proposed detection and tracking approaches have been evaluated by multiple different datasets, and the results illustrate the effectiveness of the proposed methods. This research is expected to significantly benefit many transportation applications, such as the multimodal traffic performance measure, pedestrian behavior study and pedestrian-vehicle crash analysis. Future work will focus on using fused thermal and visual images to further improve the detection efficiency and effectiveness.
A protocol for evaluating video trackers under real-world conditions.
Nawaz, Tahir; Cavallaro, Andrea
2013-04-01
The absence of a commonly adopted performance evaluation framework is hampering advances in the design of effective video trackers. In this paper, we present a single-score evaluation measure and a protocol to objectively compare trackers. The proposed measure evaluates tracking accuracy and failure, and combines them for both summative and formative performance assessment. The proposed protocol is composed of a set of trials that evaluate the robustness of trackers on a range of test scenarios representing several real-world conditions. The protocol is validated on a set of sequences with a diversity of targets (head, vehicle and person) and challenges (occlusions, background clutter, pose changes and scale changes) using six state-of-the-art trackers, highlighting their strengths and weaknesses on more than 187000 frames. The software implementing the protocol and the evaluation results are made available online and new results can be included, thus facilitating the comparison of trackers.
Determinants for Sustained Use of an Activity Tracker: Observational Study
Moons, Jonas; Kerkhof, Peter; Wiekens, Carina; De Groot, Martijn
2017-01-01
Background A lack of physical activity is considered to cause 6% of deaths globally. Feedback from wearables such as activity trackers has the potential to encourage daily physical activity. To date, little research is available on the natural development of adherence to activity trackers or on potential factors that predict which users manage to keep using their activity tracker during the first year (and thereby increasing the chance of healthy behavior change) and which users discontinue using their trackers after a short time. Objective The aim of this study was to identify the determinants for sustained use in the first year after purchase. Specifically, we look at the relative importance of demographic and socioeconomic, psychological, health-related, goal-related, technological, user experience–related, and social predictors of feedback device use. Furthermore, this study tests the effect of these predictors on physical activity. Methods A total of 711 participants from four urban areas in France received an activity tracker (Fitbit Zip) and gave permission to use their logged data. Participants filled out three Web-based questionnaires: at start, after 98 days, and after 232 days to measure the aforementioned determinants. Furthermore, for each participant, we collected activity data tracked by their Fitbit tracker for 320 days. We determined the relative importance of all included predictors by using Random Forest, a machine learning analysis technique. Results The data showed a slow exponential decay in Fitbit use, with 73.9% (526/711) of participants still tracking after 100 days and 16.0% (114/711) of participants tracking after 320 days. On average, participants used the tracker for 129 days. Most important reasons to quit tracking were technical issues such as empty batteries and broken trackers or lost trackers (21.5% of all Q3 respondents, 130/601). Random Forest analysis of predictors revealed that the most influential determinants were age, user experience–related factors, mobile phone type, household type, perceived effect of the Fitbit tracker, and goal-related factors. We explore the role of those predictors that show meaningful differences in the number of days the tracker was worn. Conclusions This study offers an overview of the natural development of the use of an activity tracker, as well as the relative importance of a range of determinants from literature. Decay is exponential but slower than may be expected from existing literature. Many factors have a small contribution to sustained use. The most important determinants are technical condition, age, user experience, and goal-related factors. This finding suggests that activity tracking is potentially beneficial for a broad range of target groups, but more attention should be paid to technical and user experience–related aspects of activity trackers. PMID:29084709
Electron-phonon mediated heat flow in disordered graphene
NASA Astrophysics Data System (ADS)
Chen, Wei; Clerk, Aashish A.
2012-09-01
We calculate the heat flux and electron-phonon thermal conductance in a disordered graphene sheet, going beyond a Fermi’s golden rule approach to fully account for the modification of the electron-phonon interaction by disorder. Using the Keldysh technique combined with standard impurity averaging methods in the regime kFl≫1 (where kF is the Fermi wave vector and l is the mean free path), we consider both scalar potential (i.e., deformation potential) and vector-potential couplings between electrons and phonons. We also consider the effects of electronic screening at the Thomas-Fermi level. We find that the temperature dependence of the heat flux and thermal conductance is sensitive to the presence of disorder and screening, and reflects the underlying chiral nature of electrons in graphene and the corresponding modification of their diffusive behavior. In the case of weak screening, disorder enhances the low-temperature heat flux over the clean system (changing the associated power law from T4 to T3), and the deformation potential dominates. For strong screening, both the deformation potential and vector-potential couplings make comparable contributions, and the low-temperature heat flux obeys a T5 power law.
NASA Technical Reports Server (NTRS)
Martin, Jerry L.; Cloyd, Jason H.
2007-01-01
A modification of the design of the pulse tube in a pulse-tube cryocooler reduces axial thermal conductance while preserving radial thermal conductance. It is desirable to minimize axial thermal conductance in the pulse-tube wall to minimize leakage of heat between the warm and cold ends of the pulse tube. At the same time, it is desirable to maximize radial thermal conductance at the cold end of the pulse tube to ensure adequate thermal contact between (1) a heat exchanger in the form of a stack of copper screens inside the pulse tube at the cold end and (2) the remainder of the cold tip, which is the object to which the heat load is applied and from which heat must be removed. The modified design yields a low-heat-leak pulse tube that can be easily integrated with a cold tip. A typical pulse tube of prior design is either a thin-walled metal tube or a metal tube with a nonmetallic lining. It is desirable that the outer surface of a pulse tube be cylindrical (in contradistinction to tapered) to simplify the design of a regenerator that is also part of the cryocooler. Under some conditions, it is desirable to taper the inner surface of the pulse tube to reduce acoustic streaming. The combination of a cylindrical outer surface and a tapered inner surface can lead to unacceptably large axial conduction if the pulse tube is made entirely of metal. Making the pulse-tube wall of a nonmetallic, lowthermal- conductivity material would not solve the problem because the wall would not afford the needed thermal contact for the stack of screens in the cold end. The modified design calls for fabricating the pulse tube in two parts: a longer, nonmetallic part that is tapered on the inside and cylindrical on the outside and a shorter, metallic part that is cylindrical on both the inside and the outside. The nonmetallic part can be made from G-10 fiberglass-reinforced epoxy or other low-thermal-conductivity, cryogenically compatible material. The metallic part must have high thermal conductivity in the cryogenic temperature range and would typically be made of pure copper to satisfy this requirement. The metallic part is bonded to the nonmetallic part with epoxy. Copper screens are inserted in the metallic part to form the cold-end heat exchanger, then the assembled pulse tube is inserted in the cold tip.
Optical Alignment of the Global Precipitation Measurement (GPM) Star Trackers
NASA Technical Reports Server (NTRS)
Hetherington, Samuel; Osgood, Dean; McMann, Joe; Roberts, Viki; Gill, James; Mclean, Kyle
2013-01-01
The optical alignment of the star trackers on the Global Precipitation Measurement (GPM) core spacecraft at NASA Goddard Space Flight Center (GSFC) was challenging due to the layout and structural design of the GPM Lower Bus Structure (LBS) in which the star trackers are mounted as well as the presence of the star tracker shades that blocked line-of-sight to the primary star tracker optical references. The initial solution was to negotiate minor changes in the original LBS design to allow for the installation of a removable item of ground support equipment (GSE) that could be installed whenever measurements of the star tracker optical references were needed. However, this GSE could only be used to measure secondary optical reference cube faces not used by the star tracker vendor to obtain the relationship information and matrix transformations necessary to determine star tracker alignment. Unfortunately, due to unexpectedly large orthogonality errors between the measured secondary adjacent cube faces and the lack of cube calibration data, we required a method that could be used to measure the same reference cube faces as originally measured by the vendor. We describe an alternative technique to theodolite auto-collimation for measurement of an optical reference mirror pointing direction when normal incidence measurements are not possible. This technique was used to successfully align the GPM star trackers and has been used on a number of other NASA flight projects. We also discuss alignment theory as well as a GSFC-developed theodolite data analysis package used to analyze angular metrology data.
Elliptically framed tip-tilt mirror optimized for stellar tracking
NASA Astrophysics Data System (ADS)
Clark, James H.; Penado, F. E.; Petak, Jeremy
2015-09-01
We compare a design innovation of an elliptically framed tip-tilt optical tracker with an existing circularly framed tracker for the Navy Precision Optical Interferometer. The tracker stabilizes a 12.5 cm stellar beam on a target hundreds of meters away and requires an increase in operational frequency. We reduced mass and size by integrating an elliptical mirror as one of the rotating components, which eliminated a rotating frame. We used the same materials as the existing tracker; however, light-weighted both the aluminum frame and Zerodur® mirror. We generated a computer-aided design model, converted it into a finite element model and performed modal analysis on two load cases. In load case 1, we tied down three points on the bottom surface of the tracker corresponding to the tie-down points of the comparison tracker. This reveals a first mode (lowest) frequency of 140 Hz, a factor of two over the baseline tracker's first mode frequency of 67 Hz. In load case 2, we constrained four additional points inboard of the corners of the tracker base, for a total of seven tie-downs, simulating a firmly bolted and secured mount. The first mode of vibration for this case is 211 Hz, an increase over load case 1 by a factor of 1.5 and more than three times the fundamental frequency of the existing tracker. We conclude that these geometrical changes with the additional tie-down bolts are a viable solution path forward to improve steering speed and recommend a continuation with this effort.
Dobrowolski, Steven F; McKinney, Jason T; Amat di San Filippo, Cristina; Giak Sim, Keow; Wilcken, Bridget; Longo, Nicola
2005-03-01
Primary carnitine deficiency is an autosomal recessive disorder of fatty acid oxidation resulting from defective carnitine transport. This disease is caused by mutations in the OCTN2 carnitine transporter encoded by the SLC22A5 gene. Here we validate dye-binding/high-resolution thermal denaturation as a screening procedure to identify novel mutations in this gene. This procedure is based on the amplification of DNA by PCR in capillaries with the dsDNA binding dye LCGreen I. The PCR reaction is then analyzed in the same capillary by high-resolution thermal denaturation. Samples with abnormal melting profiles are sequenced. This technique correctly identified all known patients who were compound heterozygotes for different mutations in the carnitine transporter gene and about 30% of homozygous patients. The remaining 70% of homozygous patients were identified by a second amplification, in which the patient's DNA was mixed with the DNA of a normal control. This screening system correctly identified eight novel mutations and both abnormal alleles in six new families with primary carnitine deficiency. The causative role of the missense mutations identified (c.3G>T/p.M1I, c.695C>T/p.T232M, and c.1403 C>G/p.T468R) was confirmed by expression in Chinese hamster ovary (CHO) cells. These results expand the mutational spectrum in primary carnitine deficiency and indicate dye-binding/high-resolution thermal denaturation as an ideal system to screen for mutations in diseases with no prevalent molecular alteration. (c) 2005 Wiley-Liss, Inc.
Beekman, Emmylou; Braun, Susy M; Ummels, Darcy; van Vijven, Kim; Moser, Albine; Beurskens, Anna J
2017-01-01
For older people and people with a chronic disease, physical activity provides health benefits. Patients and healthcare professionals can use commercially available activity trackers to objectively monitor (alterations in) activity levels and patterns and to support physical activity. However, insight in the validity, reliability, and feasibility of these trackers in people with a chronic disease is needed. In this article, a study protocol is described in which the validity, reliability (part A), and feasibility from a patient and therapist's point of view (part B) of commercially available activity trackers in daily life and health care is investigated. In part A, a quantitative cross-sectional study, an activity protocol that simulates everyday life activities will be used to determine the validity and reliability of nine commercially available activity trackers. Video recordings will act as the gold standard. In part B, a qualitative participatory action research study will be performed to gain insight in the use of activity trackers in peoples' daily life and therapy settings. Objective feasibility of the activity trackers will be measured with questionnaires, and subjective feasibility (experiences) will be explored in a community of practice. Physical therapists ( n = 8) will regularly meet during 6 months to learn from each other regarding the actual use of activity trackers in therapy. Therapists and patients ( n = 48) will decide together which tracker will be used in therapy and for which purpose (e.g., monitoring, goal setting). Data from the therapist' and patients' experiences will be collected by interviews (individual and focus groups) and analyzed by a directed content analysis. At the time of submission, selection of activity trackers, development of the activity protocol, and the ethical approval process are finished. Data collection and data processing are ongoing. The relevance of the study as well as the advantages and disadvantages of several aspects of the chosen design are discussed. The results acquired from both study parts can be used to create decision aids that may assist therapists and people with a chronic disease in choosing a suitable activity tracker, and to facilitate use of these activity trackers in health care settings. Ethical approval has been obtained from two medical-ethical committees (nr. 15-N-109, 15-N-48 and MEC-15-07).
Grumman S2F-1 Tracker at NACA Lewis
1956-08-21
The NACA’s Lewis Flight Propulsion Laboratory acquired the Grumman S2F-1 Tracker from the Navy in 1955 to study icing instrumentation. Lewis’s icing research program was winding down at the time. The use of jet engines was increasing thus reducing the threat of ice accumulation. Nonetheless Lewis continued research on the instrumentation used to detect icing conditions. The S2F-1 Tracker was a carrier-based submarine hunter for the Navy. Grumman developed the Tracker as a successor to its Korean War-era Guardian patrol aircraft. Prototypes first flew in late 1952 and battle-ready versions entered Naval service in early 1954. The Navy utilized the Trackers to protect fleets from attack.
Mesopores induced zero thermal expansion in single-crystal ferroelectrics.
Ren, Zhaohui; Zhao, Ruoyu; Chen, Xing; Li, Ming; Li, Xiang; Tian, He; Zhang, Ze; Han, Gaorong
2018-04-24
For many decades, zero thermal expansion materials have been the focus of numerous investigations because of their intriguing physical properties and potential applications in high-precision instruments. Different strategies, such as composites, solid solution and doping, have been developed as promising approaches to obtain zero thermal expansion materials. However, microstructure controlled zero thermal expansion behavior via interface or surface has not been realized. Here we report the observation of an impressive zero thermal expansion (volumetric thermal expansion coefficient, -1.41 × 10 -6 K -1 , 293-623 K) in single-crystal ferroelectric PbTiO 3 fibers with large-scale faceted and enclosed mesopores. The zero thermal expansion behavior is attributed to a synergetic effect of positive thermal expansion near the mesopores due to the oxygen-based polarization screening and negative thermal expansion from an intrinsic ferroelectricity. Our results show that a fascinating surface construction in negative thermal expansion ferroelectric materials could be a promising strategy to realize zero thermal expansion.
Geometric Model for Tracker-Target Look Angles and Line of Slight Distance
2015-10-20
412TW-PA-15239 Geometric Model for Tracker -Target Look Angles and Line of Slight Distance DANIEL T. LAIRD AIR FORCE TEST CENTER EDWARDS...15 – 23 OCT 15 4. TITLE AND SUBTITLE Geometric Model for Tracker -Target Look Angles and Line of Slight Distance 5a. CONTRACT...include area code) 661-277-8615 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 GEOMETRIC MODEL FOR TRACKER -TARGET LOOK ANGLES
Integration of an Apple II Plus Computer into an Existing Dual Axis Sun Tracker System.
1984-06-01
Identify by block number) S, tpec l Sun Tracker System Solar Energy Apple II Plus Computer 20. ABSTRACT (’ ntlnue on reveree ide If neceesery end...14 4. Dual Axis Sun Tracker (Side View) ----------------- 15 5. Solar Tracker System Block Diagram ---------------- 17 6. Plug Wiring Diagram for Top...sources will be competitive. Already many homes have solar collectors and other devices designed to decrease the consumption of gas, oil, and
Thermal modifications of charmonia and bottomonia from spatial correlation functions
NASA Astrophysics Data System (ADS)
Ding, Heng-Tong; Kaczmarek, Olaf; Kruse, Anna-lena; Mukherjee, Swagato; Ohno, Hiroshi; Sandmeyer, Hauke; Shu, Hai-Tao
2018-03-01
We present our study on the thermal modifications of charmonia and bottomonia from spatial correlation functions at zero and nonzero momenta in quenched QCD. To accommodate the heavy quarks on the lattice we performed simulations on very fine lattices at a fixed beta value corresponding to a lattice spacing a-1 = 22:8 GeV on 1923×32, 1923 × 48, 1923 × 56, 1923 × 64 and 1923 × 96 lattices using clover-improved Wilson fermions. These lattices correspond to temperatures of 2.25Tc, 1.50Tc, 1.25Tc, 1.10Tc and 0.75Tc. To increase the signal to noise ratio in the axial-vector and scalar channels we used multi-sources for the measurement of spatial correlation functions. By investigating on the differences between spatial and temporal correlators as well as the temperature dependence of screening masses we will discuss the thermal effects in different channels of quarkonium states. Besides this the dispersion relation of the screening mass at different momenta is also discussed.
Electrical Transport Properties of Liquid Sn-Sb Binary Alloys
NASA Astrophysics Data System (ADS)
Thakore, B. Y.; Suthar, P. H.; Khambholja, S. G.; Jani, A. R.
2010-06-01
The study of electrical transport properties viz. electrical resistivity, thermo electrical power and thermal conductivity of liquid Sn-Sb binary alloys have been made by our well recognized single parametric model potential. In the present work, screening functions due to Hartree, Taylor, Ichimaru et al.. Farid et al.. and Sarkar et al.. have been employed to incorporate the exchange and correlation effects. The liquid alloy is studied as a function of its composition at temperature 823 K according to the Faber-Ziman model. Further, thermoelectric power and thermal conductivity have been predicted. The values of electrical resistivity of binary alloys computed with Ichimaru et al. and Farid et al.. screening function are in good agreement with the experimental data.
40 CFR 63.443 - Standards for the pulping system at kraft, soda, and semi-chemical processes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... furnace with a heat input capacity greater than or equal to 44 megawatts (150 million British thermal...) Each screen system; (iii) Each decker system; and (iv) Each weak liquor storage tank. (b) The owner or... concentration at the outlet of the thermal oxidizer to 20 parts per million or less by volume, corrected to 10...
Development of An Advanced JP-8 Fuel
1993-12-01
included the Microthermal Precipitation Test (MTP), Fuel Reactor Test, Hot Liquid Process Simulator (HLPS), and Isothermal Corrosion Oxidation Test (ICOT... Microthermal Precipitation Test The impetus for this development effort was the need for a screening test that could discriminate between fuels of...varying propensity to produce thermally induced insoluble particulate material in the bulk fuel. The Microthermal Precipitation (MTP) test thermally
NASA Astrophysics Data System (ADS)
Likun, Wang; Weili, Li; Yi, Xue; Chunwei, Guan
2013-11-01
A significant problem of turbogenerators on complex end structures is overheating of local parts caused by end losses in the end region. Therefore, it is important to investigate the 3-D magnetic field and eddy current loss in the end. In end region of operating large turbogenerator at thermal power plants, magnetic leakage field distribution is complex. In this paper, a 3-D mathematical model used for the calculation of the electromagnetic field in the end region of large turbo-generators is given. The influence of spatial locations of end structures, the actual shape and material of end windings, clamping plate, and copper screen are considered. Adopting the time-step finite element (FE) method and taking the nonlinear characteristics of the core into consideration, a 3-D transient magnetic field is calculated. The objective of this paper is to investigate the influence of clamping plate permeability and metal screen structures on 3-D electromagnetic field distribution and eddy current loss in end region of a turbo-generator. To reduce the temperature of copper screen, a hollow metal screen is proposed. The eddy current loss, which is gained from the 3D transient magnetic field, is used as heat source for the thermal field of end region. The calculated temperatures are compared with test data.
Zabek, Daniel; Seunarine, Kris; Spacie, Chris; Bowen, Chris
2017-03-15
Thermal energy can be effectively converted into electricity using pyroelectrics, which act as small scale power generator and energy harvesters providing nanowatts to milliwatts of electrical power. In this paper, a novel pyroelectric harvester based on free-standing poly(vinylidene difluoride) (PVDF) was manufactured that exploits the high thermal radiation absorbance of a screen printed graphene ink electrode structure to facilitate the conversion of the available thermal radiation energy into electrical energy. The use of interconnected graphene nanoplatelets (GNPs) as an electrode enable high thermal radiation absorbance and high electrical conductivity along with the ease of deposition using a screen print technique. For the asymmetric structure, the pyroelectric open-circuit voltage and closed-circuit current were measured, and the harvested electrical energy was stored in an external capacitor. For the graphene ink/PVDF/aluminum system the closed circuit pyroelectric current improves by 7.5 times, the open circuit voltage by 3.4 times, and the harvested energy by 25 times compared to a standard aluminum/PVDF/aluminum system electrode design, with a peak energy density of 1.13 μJ/cm 3 . For the pyroelectric device employed in this work, a complete manufacturing process and device characterization of these structures are reported along with the thermal conductivity of the graphene ink. The material combination presented here provides a new approach for delivering smart materials and structures, wireless technologies, and Internet of Things (IoT) devices.
Ummels, Darcy; Beekman, Emmylou; Theunissen, Kyra; Braun, Susy; Beurskens, Anna J
2018-04-02
Measuring physical activity with commercially available activity trackers is gaining popularity. People with a chronic disease can especially benefit from knowledge about their physical activity pattern in everyday life since sufficient physical activity can contribute to wellbeing and quality of life. However, no validity data are available for this population during activities of daily living. The aim of this study was to investigate the validity of 9 commercially available activity trackers for measuring step count during activities of daily living in people with a chronic disease receiving physiotherapy. The selected activity trackers were Accupedo (Corusen LLC), Activ8 (Remedy Distribution Ltd), Digi-Walker CW-700 (Yamax), Fitbit Flex (Fitbit inc), Lumoback (Lumo Bodytech), Moves (ProtoGeo Oy), Fitbit One (Fitbit inc), UP24 (Jawbone), and Walking Style X (Omron Healthcare Europe BV). In total, 130 persons with chronic diseases performed standardized activity protocols based on activities of daily living that were recorded on video camera and analyzed for step count (gold standard). The validity of the trackers' step count was assessed by correlation coefficients, t tests, scatterplots, and Bland-Altman plots. The correlations between the number of steps counted by the activity trackers and the gold standard were low (range: -.02 to .33). For all activity trackers except for Fitbit One, a significant systematic difference with the gold standard was found for step count. Plots showed a wide range in scores for all activity trackers; Activ8 showed an average overestimation and the other 8 trackers showed underestimations. This study showed that the validity of 9 commercially available activity trackers is low measuring steps while individuals with chronic diseases receiving physiotherapy engage in activities of daily living. ©Darcy Ummels, Emmylou Beekman, Kyra Theunissen, Susy Braun, Anna J Beurskens. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 02.04.2018.
Study of multilayer thermal insulation by inverse problems method
NASA Astrophysics Data System (ADS)
Alifanov, O. M.; Nenarokomov, A. V.; Gonzalez, V. M.
2009-11-01
The purpose of this paper is to introduce a new method in the research of radiative and thermal properties of materials with further applications in the design of thermal control systems (TCS) of spacecrafts. In this paper the radiative and thermal properties (emissivity and thermal conductance) of a multilayered thermal-insulating blanket (MLI), which is a screen-vacuum thermal insulation as a part of the TCS for perspective spacecrafts, are estimated. Properties of the materials under study are determined in the result of temperature and heat flux measurement data processing based on the solution of the inverse heat transfer problem (IHTP) technique. Given are physical and mathematical models of heat transfer processes in a specimen of the multilayered thermal-insulating blanket located in the experimental facility. A mathematical formulation of the inverse heat conduction problem is presented as well. The practical approves were made for specimen of the real MLI.
Suzuki, Ayuko; Shinozaki, Jun; Yazawa, Shogo; Ueki, Yoshino; Matsukawa, Noriyuki; Shimohama, Shun; Nagamine, Takashi
2018-01-01
The mental rotation task is well-known for the assessment of visuospatial function; however, it has not been used for screening of dementia patients. The aim of this study was to create a simple screening test for patients with mild cognitive impairment (MCI) and Alzheimer's disease (AD) by focusing on non-amnestic symptoms. Age-matched healthy controls (age 75.3±6.8), patients with MCI (76.5±5.5), and AD (78.2±5.0) participated in this study. They carried out mental rotation tasks targeting geometric graphics or alphabetical characters with three rotating angles (0°, 90°, and 180°) and indicated the correct answer. Response accuracy and reaction time were recorded along with their eye movements using an eye tracker. To quantify their visual processing strategy, the run count ratio (RC ratio) was calculated by dividing the mean number of fixations in incorrect answers by that in correct answers. AD patients showed lower accuracy and longer reaction time than controls. They also showed a significantly greater number of fixation and smaller saccade amplitude than controls, while fixation duration did not differ significantly. The RC ratio was higher for AD, followed by MCI and control groups. By setting the cut-off value to 0.47 in the 180° rotating angle task, we could differentiate MCI patients from controls with a probability of 80.0%. We established a new screening system for dementia patients by evaluating visuospatial function. The RC ratio during a mental rotation task is useful for discriminating MCI patients from controls.
Co-training Framework of Generative and Disciminative Trackers with Partial Occlusion Handling
2011-01-01
ARO W911NF-06-1-0094. The first author was also supported by the Vietnam Education Foundation. We thank Zdenek Kalal for his help with the P-N Tracker...handling challenging situations with cluttered background. Recently, Kalal et al. [11] proposed the P-N Tracker us- ing positive and negative constraints to...Vietnam Education Foundation. We thank Zdenek Kalal for his help with the P-N Tracker [11]. References [1] A. Adam, E. Rivlin, and I. Shimshoni. Robust
Thermal management approaches of Cu(In x ,Ga1-x )Se2 micro-solar cells
NASA Astrophysics Data System (ADS)
Sancho-Martínez, Diego; Schmid, Martina
2017-11-01
Concentrator photovoltaics (CPV) is a cost-effective method for generating electricity in regions that have a large fraction of direct solar radiation. With the help of lenses, sunlight is concentrated onto miniature, highly efficient multi-junction solar cells with a photovoltaic performance above 40%. To ensure illumination with direct radiation, CPV modules must be installed on trackers to follow the sun’s path. However, the costs of huge concentration optics and the photovoltaic technology used, narrow the market possibilities for CPV technology. Efforts to reduce these costs are being undertaken by the promotion of Cu(In x ,Ga1-x )Se2 solar cells to take over the high cost multi-junction solar cells and implementing more compact devices by minimization of solar cell area. Micrometer-sized absorbers have the potential of low cost, high efficiencies and good thermal dissipation under concentrated illumination. Heat dissipation at low (<10×) to medium (10 × to 100×) flux density distributions is the key point of high concentration studies for macro- and micro-sized solar cells (from 1 µm2 to 1 mm2). To study this thermal process and to optimize it, critical parameters must be taken in account: absorber area, substrate area and thickness, structure design, heat transfer mechanism, concentration factor and illumination profile. A close study on them will be carried out to determine the best structure to enhance and reach the highest possible thermal management pointing to an efficiency improvement.
Muralikrishnan, B.; Blackburn, C.; Sawyer, D.; Phillips, S.; Bridges, R.
2010-01-01
We describe a method to estimate the scale errors in the horizontal angle encoder of a laser tracker in this paper. The method does not require expensive instrumentation such as a rotary stage or even a calibrated artifact. An uncalibrated but stable length is realized between two targets mounted on stands that are at tracker height. The tracker measures the distance between these two targets from different azimuthal positions (say, in intervals of 20° over 360°). Each target is measured in both front face and back face. Low order harmonic scale errors can be estimated from this data and may then be used to correct the encoder’s error map to improve the tracker’s angle measurement accuracy. We have demonstrated this for the second order harmonic in this paper. It is important to compensate for even order harmonics as their influence cannot be removed by averaging front face and back face measurements whereas odd orders can be removed by averaging. We tested six trackers from three different manufacturers. Two of those trackers are newer models introduced at the time of writing of this paper. For older trackers from two manufacturers, the length errors in a 7.75 m horizontal length placed 7 m away from a tracker were of the order of ± 65 μm before correcting the error map. They reduced to less than ± 25 μm after correcting the error map for second order scale errors. Newer trackers from the same manufacturers did not show this error. An older tracker from a third manufacturer also did not show this error. PMID:27134789
Beekman, Emmylou; Theunissen, Kyra; Braun, Susy; Beurskens, Anna J
2018-01-01
Background Measuring physical activity with commercially available activity trackers is gaining popularity. People with a chronic disease can especially benefit from knowledge about their physical activity pattern in everyday life since sufficient physical activity can contribute to wellbeing and quality of life. However, no validity data are available for this population during activities of daily living. Objective The aim of this study was to investigate the validity of 9 commercially available activity trackers for measuring step count during activities of daily living in people with a chronic disease receiving physiotherapy. Methods The selected activity trackers were Accupedo (Corusen LLC), Activ8 (Remedy Distribution Ltd), Digi-Walker CW-700 (Yamax), Fitbit Flex (Fitbit inc), Lumoback (Lumo Bodytech), Moves (ProtoGeo Oy), Fitbit One (Fitbit inc), UP24 (Jawbone), and Walking Style X (Omron Healthcare Europe BV). In total, 130 persons with chronic diseases performed standardized activity protocols based on activities of daily living that were recorded on video camera and analyzed for step count (gold standard). The validity of the trackers’ step count was assessed by correlation coefficients, t tests, scatterplots, and Bland-Altman plots. Results The correlations between the number of steps counted by the activity trackers and the gold standard were low (range: –.02 to .33). For all activity trackers except for Fitbit One, a significant systematic difference with the gold standard was found for step count. Plots showed a wide range in scores for all activity trackers; Activ8 showed an average overestimation and the other 8 trackers showed underestimations. Conclusions This study showed that the validity of 9 commercially available activity trackers is low measuring steps while individuals with chronic diseases receiving physiotherapy engage in activities of daily living. PMID:29610110
Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed.
Fokkema, Tryntsje; Kooiman, Thea J M; Krijnen, Wim P; VAN DER Schans, Cees P; DE Groot, Martijn
2017-04-01
To examine the test-retest reliability and validity of ten activity trackers for step counting at three different walking speeds. Thirty-one healthy participants walked twice on a treadmill for 30 min while wearing 10 activity trackers (Polar Loop, Garmin Vivosmart, Fitbit Charge HR, Apple Watch Sport, Pebble Smartwatch, Samsung Gear S, Misfit Flash, Jawbone Up Move, Flyfit, and Moves). Participants walked three walking speeds for 10 min each; slow (3.2 km·h), average (4.8 km·h), and vigorous (6.4 km·h). To measure test-retest reliability, intraclass correlations (ICC) were determined between the first and second treadmill test. Validity was determined by comparing the trackers with the gold standard (hand counting), using mean differences, mean absolute percentage errors, and ICC. Statistical differences were calculated by paired-sample t tests, Wilcoxon signed-rank tests, and by constructing Bland-Altman plots. Test-retest reliability varied with ICC ranging from -0.02 to 0.97. Validity varied between trackers and different walking speeds with mean differences between the gold standard and activity trackers ranging from 0.0 to 26.4%. Most trackers showed relatively low ICC and broad limits of agreement of the Bland-Altman plots at the different speeds. For the slow walking speed, the Garmin Vivosmart and Fitbit Charge HR showed the most accurate results. The Garmin Vivosmart and Apple Watch Sport demonstrated the best accuracy at an average walking speed. For vigorous walking, the Apple Watch Sport, Pebble Smartwatch, and Samsung Gear S exhibited the most accurate results. Test-retest reliability and validity of activity trackers depends on walking speed. In general, consumer activity trackers perform better at an average and vigorous walking speed than at a slower walking speed.
Individual Differences in the Attribution of Incentive Salience to a Pavlovian Alcohol Cue.
Villaruel, Franz R; Chaudhri, Nadia
2016-01-01
Individual differences exist in the attribution of incentive salience to conditioned stimuli associated with food. Here, we investigated whether individual differences also manifested with a Pavlovian alcohol conditioned stimulus (CS). We compiled data from five experiments that used a Pavlovian autoshaping paradigm and tests of conditioned reinforcement. In all experiments, male, Long-Evans rats with unrestricted access to food and water were acclimated to 15% ethanol. Next, rats received Pavlovian autoshaping training, in which a 10 s presentation of a retractable lever served as the CS and 0.2 mL of 15% ethanol served as the unconditioned stimulus (US). Finally, rats underwent conditioned reinforcement tests in which nose-pokes to an active aperture led to brief presentations of the lever-CS, but nose-pokes to an inactive aperture had no consequence. Rats were categorized as sign-trackers, goal-trackers and intermediates based on a response bias score that reflected their tendencies to sign-track or goal-track at different times during training. We found that distinct groups of rats either consistently interacted with the lever-CS ("sign-trackers") or routinely approached the port during the lever-CS ("goal-trackers") across a majority of the training sessions. However, some individuals ("shifted sign-trackers") with an early tendency to goal-track later shifted to comparable asymptotic levels of sign-tracking as the group identified as sign-trackers. The lever-CS functioned as a conditioned reinforcer for sign-trackers and shifted sign-trackers, but not for goal-trackers. These results provide evidence of robust individual differences in the extent to which a Pavlovian alcohol cue gains incentive salience and functions as a conditioned reinforcer.
Precision Attitude Determination System (PADS) design and analysis. Two-axis gimbal star tracker
NASA Technical Reports Server (NTRS)
1973-01-01
Development of the Precision Attitude Determination System (PADS) focused chiefly on the two-axis gimballed star tracker and electronics design improved from that of Precision Pointing Control System (PPCS), and application of the improved tracker for PADS at geosynchronous altitude. System design, system analysis, software design, and hardware design activities are reported. The system design encompasses the PADS configuration, system performance characteristics, component design summaries, and interface considerations. The PADS design and performance analysis includes error analysis, performance analysis via attitude determination simulation, and star tracker servo design analysis. The design of the star tracker and electronics are discussed. Sensor electronics schematics are included. A detailed characterization of the application software algorithms and computer requirements is provided.
2014-05-19
their acceptable thermal stability, Polyimides have established as a conventional substrate material for flexible interconnects, which can be...of the silver flake ink for the screen-printed interconnects, the assembled unit fulfills biocompatibility requirements in a limited manner ([29...30]). Even though biocompatibility of substrate [31] is fulfilled, toxicity of the insulating mask [32] and encapsulation need to be considered
2008-07-01
for the redesign of the previously fielded 66mm M76 grenade. Although the M76 grenades provided effective screening in the visual and thermal IR...Environmental and Field Testing Team, Engineering Directorate (ECBC), for coordinating and transporting the test items to the downrange testing site and to...13 2.2 Experimental Design-Downrange Testing ............................................. 14 2.3
Thermally Driven Electronic Topological Transition in FeTi
NASA Astrophysics Data System (ADS)
Yang, F. C.; Muñoz, J. A.; Hellman, O.; Mauger, L.; Lucas, M. S.; Tracy, S. J.; Stone, M. B.; Abernathy, D. L.; Xiao, Yuming; Fultz, B.
2016-08-01
Ab initio molecular dynamics, supported by inelastic neutron scattering and nuclear resonant inelastic x-ray scattering, showed an anomalous thermal softening of the M5- phonon mode in B 2 -ordered FeTi that could not be explained by phonon-phonon interactions or electron-phonon interactions calculated at low temperatures. A computational investigation showed that the Fermi surface undergoes a novel thermally driven electronic topological transition, in which new features of the Fermi surface arise at elevated temperatures. The thermally induced electronic topological transition causes an increased electronic screening for the atom displacements in the M5- phonon mode and an adiabatic electron-phonon interaction with an unusual temperature dependence.
Sun tracker for clear or cloudy weather
NASA Technical Reports Server (NTRS)
Scott, D. R.; White, P. R.
1979-01-01
Sun tracker orients solar collector so that they absorb maximum possible sunlight without being fooled by bright clouds, holes in cloud cover, or other atmospheric conditions. Tracker follows sun within 0.25 deg arc and is accurate within + or - 5 deg when sun is hidden.
Walker, Rachel K; Hickey, Amanda M; Freedson, Patty S
2016-12-01
Exercise, light physical activity, and decreased sedentary time all have been associated with health benefits following cancer diagnoses. Commercially available wearable activity trackers may help patients monitor and self-manage their behaviors to achieve these benefits. This article highlights some advantages and limitations clinicians should be aware of when discussing the use of activity trackers with cancer survivors. Limited research has assessed the accuracy of commercially available activity trackers compared to research-grade devices. Because most devices use confidential, proprietary algorithms to convert accelerometry data to meaningful output like total steps, assessing whether these algorithms account for differences in gait abnormalities, functional limitations, and different body morphologies can be difficult. Quantification of sedentary behaviors and light physical activities present additional challenges. The global market for activity trackers is growing, which presents clinicians with a tremendous opportunity to incorporate these devices into clinical practice as tools to promote activity. This article highlights important considerations about tracker accuracy and usage by cancer survivors.
Spacecraft angular velocity estimation algorithm for star tracker based on optical flow techniques
NASA Astrophysics Data System (ADS)
Tang, Yujie; Li, Jian; Wang, Gangyi
2018-02-01
An integrated navigation system often uses the traditional gyro and star tracker for high precision navigation with the shortcomings of large volume, heavy weight and high-cost. With the development of autonomous navigation for deep space and small spacecraft, star tracker has been gradually used for attitude calculation and angular velocity measurement directly. At the same time, with the dynamic imaging requirements of remote sensing satellites and other imaging satellites, how to measure the angular velocity in the dynamic situation to improve the accuracy of the star tracker is the hotspot of future research. We propose the approach to measure angular rate with a nongyro and improve the dynamic performance of the star tracker. First, the star extraction algorithm based on morphology is used to extract the star region, and the stars in the two images are matched according to the method of angular distance voting. The calculation of the displacement of the star image is measured by the improved optical flow method. Finally, the triaxial angular velocity of the star tracker is calculated by the star vector using the least squares method. The method has the advantages of fast matching speed, strong antinoise ability, and good dynamic performance. The triaxial angular velocity of star tracker can be obtained accurately with these methods. So, the star tracker can achieve better tracking performance and dynamic attitude positioning accuracy to lay a good foundation for the wide application of various satellites and complex space missions.
Experimental predictions drawn from a computational model of sign-trackers and goal-trackers.
Lesaint, Florian; Sigaud, Olivier; Clark, Jeremy J; Flagel, Shelly B; Khamassi, Mehdi
2015-01-01
Gaining a better understanding of the biological mechanisms underlying the individual variation observed in response to rewards and reward cues could help to identify and treat individuals more prone to disorders of impulsive control, such as addiction. Variation in response to reward cues is captured in rats undergoing autoshaping experiments where the appearance of a lever precedes food delivery. Although no response is required for food to be delivered, some rats (goal-trackers) learn to approach and avidly engage the magazine until food delivery, whereas other rats (sign-trackers) come to approach and engage avidly the lever. The impulsive and often maladaptive characteristics of the latter response are reminiscent of addictive behaviour in humans. In a previous article, we developed a computational model accounting for a set of experimental data regarding sign-trackers and goal-trackers. Here we show new simulations of the model to draw experimental predictions that could help further validate or refute the model. In particular, we apply the model to new experimental protocols such as injecting flupentixol locally into the core of the nucleus accumbens rather than systemically, and lesioning of the core of the nucleus accumbens before or after conditioning. In addition, we discuss the possibility of removing the food magazine during the inter-trial interval. The predictions from this revised model will help us better understand the role of different brain regions in the behaviours expressed by sign-trackers and goal-trackers. Copyright © 2014 Elsevier Ltd. All rights reserved.
NC-TEST: noncontact thermal emissions screening technique for drug and alcohol detection
NASA Astrophysics Data System (ADS)
Prokoski, Francine J.
1997-01-01
Drug abuse is highly correlated with criminal behavior. The typical drug-using criminal commits hundreds of crimes per year. The crime rate cannot be significantly reduced without a reduction in the percentage of the population abusing drugs and alcohol. Accurate and timely estimation of that percentage is important for policy decisions concerning crime control, public health measures, allocation of intervention resources for prevention and treatment, projections of criminal justice needs, and the evaluation of policy effectiveness. Such estimation is particularly difficult because self reporting is unreliable; and physical testing has to date required blood or urine analysis which is expensive and invasive, with the result that too few people are tested. MIKOS Ltd. has developed a non-contact, passive technique with the potential for automatic, real- time screening for drug and alcohol use. The system utilizes thermal radiation which is spontaneously and continuously emitted by the human body. Facial thermal patterns and changes in patterns are correlated with standardized effects of specific drugs and alcohol. A portable system incorporating the collection and analysis technique can be used episodically to collect data for estimating drug and alcohol use by general unknown populations such as crowds at airports, or it can be used for repetitive routine screening of specific known groups such as airline pilots, military personnel, school children, or persons on probation or parole.
The 1-kW solar Stirling experiment
NASA Technical Reports Server (NTRS)
Giandomenico, A.
1981-01-01
The objective of this experiment was to demonstrate electrical power generation using a small free-piston Stirling engine and linear alternator in conjunction with a parabolic solar collector. A test bed collector, formerly used at the JPL Table Mountain Observatory, was renovated and used to obtain practical experience and to determine test receiver performance. The collector was mounted on a two-axis tracker, with a cold water calorimeter mounted on the collector to measure its efficiency, while a separate, independently tracking radiometer was used to measure solar insolation. The solar receiver was designed to absorb energy from the collector, then transfer the resulting thermal energy to the Stirling engine. Successful testing of receiver/collector assembly yielded valuable inputs for design of the Stirling engine heater head.
Indoor characterization of the receiver for the novel InPhoCUS concrete tracker CPV system
NASA Astrophysics Data System (ADS)
Pravettoni, Mauro; Cooper, Thomas; Ambrosetti, Gianluca; Steinfeld, Aldo
2012-10-01
The Swiss consortium InPhoCUS has been formed between Airlight Energy Manufacturing SA, the Swiss Federal Institute of Technology and the University of Applied Sciences and Arts of Southern Switzerland (thermal modelling and CPV characterization and qualification, respectively). The consortium is developing an innovative 50-meter long, 9-meter wide, 2-axis concentrating system. The secondary tracking axis allows reaching concentration ratios as high as 500X. Indoor characterization of the 5-cell receiver has been performed to test the effects of the cell-to-cell non-uniformity of irradiance. Results are presented in this work and are also helpful in the development of new techniques for the indoor characterization of CPV receivers.
Fire resistant resilient foams. [for seat cushions
NASA Technical Reports Server (NTRS)
Gagliani, J.
1976-01-01
Primary program objectives were the formulation, screening, optimization and characterization of open-cell, fire resistant, low-smoke emitting, thermally stable, resilient polyimide foams suitable for seat cushions in commercial aircraft and spacecraft. Secondary program objectives were to obtain maximum improvement of the tension, elongation and tear characteristics of the foams, while maintaining the resiliency, thermal stability, low smoke emission and other desirable attributes of these materials.
Post flight analysis of NASA standard star trackers recovered from the solar maximum mission
NASA Technical Reports Server (NTRS)
Newman, P.
1985-01-01
The flight hardware returned after the Solar Maximum Mission Repair Mission was analyzed to determine the effects of 4 years in space. The NASA Standard Star Tracker would be a good candidate for such analysis because it is moderately complex and had a very elaborate calibration during the acceptance procedure. However, the recovery process extensively damaged the cathode of the image dissector detector making proper operation of the tracker and a comparison with preflight characteristics impossible. Otherwise, the tracker functioned nominally during testing.
Personal Activity Trackers and the Quantified Self.
Hoy, Matthew B
2016-01-01
Personal activity trackers are an inexpensive and easy way for people to record their physical activity and simple biometric data. As these devices have increased in availability and sophistication, their use in daily life and in medicine has grown. This column will briefly explore what these devices are, what types of data they can track, and how that data can be used. It will also discuss potential problems with trackers and how librarians can help patients and physicians manage and protect activity data. A brief list of currently available activity trackers is also included.
Waring, George O
2009-10-01
To describe recent technological additions to the NIDEK CXIII and Quest excimer lasers. A summary article with data from previous published studies outlining the benefits of newer technology. The addition of a 1-kHz infrared eye tracker decreased the spread of laser spot placement from a mean of 228.79 microm without a tracker to 38.47 microm with the eye tracker. The addition of real-time torsion error correction produced a statistically significantly lower cylinder dispersion, mean manifest refractive cylinder, and error of angle postoperatively in eyes that underwent LASIK. The incorporation of an ultrahigh speed eye tracker and active cyclotorsion correction surpasses the minimal technology criteria required for accurate wavefront-based ablations. Copyright 2009, SLACK Incorporated.
Log-polar mapping-based scale space tracking with adaptive target response
NASA Astrophysics Data System (ADS)
Li, Dongdong; Wen, Gongjian; Kuai, Yangliu; Zhang, Ximing
2017-05-01
Correlation filter-based tracking has exhibited impressive robustness and accuracy in recent years. Standard correlation filter-based trackers are restricted to translation estimation and equipped with fixed target response. These trackers produce an inferior performance when encountered with a significant scale variation or appearance change. We propose a log-polar mapping-based scale space tracker with an adaptive target response. This tracker transforms the scale variation of the target in the Cartesian space into a shift along the logarithmic axis in the log-polar space. A one-dimensional scale correlation filter is learned online to estimate the shift along the logarithmic axis. With the log-polar representation, scale estimation is achieved accurately without a multiresolution pyramid. To achieve an adaptive target response, a variance of the Gaussian function is computed from the response map and updated online with a learning rate parameter. Our log-polar mapping-based scale correlation filter and adaptive target response can be combined with any correlation filter-based trackers. In addition, the scale correlation filter can be extended to a two-dimensional correlation filter to achieve joint estimation of the scale variation and in-plane rotation. Experiments performed on an OTB50 benchmark demonstrate that our tracker achieves superior performance against state-of-the-art trackers.
Radiative-conductive inverse problem for lumped parameter systems
NASA Astrophysics Data System (ADS)
Alifanov, O. M.; Nenarokomov, A. V.; Gonzalez, V. M.
2008-11-01
The purpose of this paper is to introduce a iterative regularization method in the research of radiative and thermal properties of materials with applications in the design of Thermal Control Systems (TCS) of spacecrafts. In this paper the radiative and thermal properties (emissivity and thermal conductance) of a multilayered thermal-insulating blanket (MLI), which is a screen-vacuum thermal insulation as a part of the (TCS) for perspective spacecrafts, are estimated. Properties of the materials under study are determined in the result of temperature and heat flux measurement data processing based on the solution of the Inverse Heat Transfer Problem (IHTP) technique. Given are physical and mathematical models of heat transfer processes in a specimen of the multilayered thermal-insulating blanket located in the experimental facility. A mathematical formulation of the inverse heat conduction problem is presented too. The practical testing were performed for specimen of the real MLI.
Thermal imaging as a lie detection tool at airports.
Warmelink, Lara; Vrij, Aldert; Mann, Samantha; Leal, Sharon; Forrester, Dave; Fisher, Ronald P
2011-02-01
We tested the accuracy of thermal imaging as a lie detection tool in airport screening. Fifty-one passengers in an international airport departure hall told the truth or lied about their forthcoming trip in an interview. Their skin temperature was recorded via a thermal imaging camera. Liars' skin temperature rose significantly during the interview, whereas truth tellers' skin temperature remained constant. On the basis of these different patterns, 64% of truth tellers and 69% of liars were classified correctly. The interviewers made veracity judgements independently from the thermal recordings. The interviewers outperformed the thermal recordings and classified 72% of truth tellers and 77% of liars correctly. Accuracy rates based on the combination of thermal imaging scores and interviewers' judgements were the same as accuracy rates based on interviewers' judgements alone. Implications of the findings for the suitability of thermal imaging as a lie detection tool in airports are discussed.
The Diagnostics of the External Plasma for the Plasma Rocket
NASA Technical Reports Server (NTRS)
Karr, Gerald R.
1997-01-01
Three regions of plasma temperature/energy are being investigated to understand fully the behavior of the plasma created by the propulsion device and the operation of the RPA. Each type of plasma has a RPA associated with it; i.e. a thermal RPA, a collimated RPA, and a high temperature RPA. Through the process of developing the thermal and collimated RPAs, the proper knowledge and experience has been gained to not only design a high temperature RPA for the plasma rocket, but to understand its operation, results, and uncertainty. After completing a literature search for, reading published papers on, and discussing the operation of the RPA with electric propulsion researchers, I applied the knowledge gained to the development of a RPA for thermal plasma. A design of a thermal RPA was made which compensates for a large Debye length and low ionized plasma. From this design a thermal RPA was constructed. It consists of an outer stainless steel casing, a phenolic insulator (outgases slightly), and stainless steel mesh for the voltage screens. From the experience and knowledge gained in the development of the thermal RPA, a RPA for collimated plasma was developed. A collimated RPA has been designed and constructed. It compensate for a smaller Debye length and much higher ionization than that existing in the thermal plasma. It is 17% of the size of the thermal RPA. A stainless steel casing shields the detector from impinging electrons and ions. An insulating material, epoxy resin, was utilized which has a negligible outgassing. This material can be molded in styrofoam and machined quite nicely. It is capable of withstanding moderately high temperatures. Attached to this resin insulator are inconel screens attached by silver plated copper wire to a voltage supply. All the work on the RPAs and thermal ion source, I performed in the University of Alabama in Huntsville's (UAH) engineering machine shop.
Microscreen radiation shield for thermoelectric generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunt, T.K.; Novak, R.F.; McBride, J.R.
1990-08-14
This patent describes a radiation shield adapted to be interposed between a reaction zone and a means for condensing an alkali metal vapor in a thermoelectric generator for converting heat energy directly to electrical energy. The radiation shield comprises woven wire mesh screen, the spacing between the wires forming the mesh screen being such that the radiation shield reflects thermal radiation while permitting the passage of alkali metal vapor therethrough.
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-01
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more “hydrophilic” than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization. PMID:28054635
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece.
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-05
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more "hydrophilic" than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization.
Large scale generation of micro-droplet array by vapor condensation on mesh screen piece
NASA Astrophysics Data System (ADS)
Xie, Jian; Xu, Jinliang; He, Xiaotian; Liu, Qi
2017-01-01
We developed a novel micro-droplet array system, which is based on the distinct three dimensional mesh screen structure and sintering and oxidation induced thermal-fluid performance. Mesh screen was sintered on a copper substrate by bonding the two components. Non-uniform residue stress is generated along weft wires, with larger stress on weft wire top location than elsewhere. Oxidation of the sintered package forms micro pits with few nanograsses on weft wire top location, due to the stress corrosion mechanism. Nanograsses grow elsewhere to show hydrophobic behavior. Thus, surface-energy-gradient weft wires are formed. Cooling the structure in a wet air environment nucleates water droplets on weft wire top location, which is more “hydrophilic” than elsewhere. Droplet size is well controlled by substrate temperature, air humidity and cooling time. Because warp wires do not contact copper substrate and there is a larger conductive thermal resistance between warp wire and weft wire, warp wires contribute less to condensation but function as supporting structure. The surface energy analysis of drops along weft wires explains why droplet array can be generated on the mesh screen piece. Because the commercial material is used, the droplet system is cost effective and can be used for large scale utilization.
Smith, Melvyn Howard; Hodgson, Julian; Eltringham, Ian Joseph
2010-12-01
As health services move toward universal methicillin-resistant Staphylococcus aureus (MRSA) screening for hospital admissions, the most cost-effective approach is yet to be defined. In this study, one of the largest to date, we evaluated the performance of the BD GeneOhm MRSA assay on the Rotor-Gene 6000 thermal cycler, using samples taken directly from pooled MRSA screens. Results were compared with the same assay performed on the Smart-Cycler II platform and overnight broth culture. Samples yielding discrepant results were subjected to detailed analysis with an in-house PCR and patient note review. A total of 1,428 pooled MRSA screens were tested. Sensitivities and specificities of 85.3% and 95.8% for the Rotor-Gene and 81% and 95.7% for the Smart-Cycler were obtained, compared with broth enrichment. The sensitivity of the BD GeneOhm assay was increased to 100% when the results of in-house PCR and patient note review were taken into account. This study demonstrates that the Rotor-Gene 6000 thermal cycler is a reliable platform for use with the BD GeneOhm assay. It also proves that commercial PCR can be performed direct on pooled samples in selective broth, without the need for overnight incubation.
Often Overlooked Obstacles of Office Landscaping
ERIC Educational Resources Information Center
Jenkins, William A.; Shoaf, Lawrence G.
1973-01-01
Discusses nine of the most serious limitations of the office landscape concept: status screens, noise level, privacy problem, hazard control, security, unjustifiable changes, thermal environment, storage, and future planning. (Author/MF)
Infant Eyes: A Window on Cognitive Development
ERIC Educational Resources Information Center
Aslin, Richard N.
2012-01-01
Eye-trackers suitable for use with infants are now marketed by several commercial vendors. As eye-trackers become more prevalent in infancy research, there is the potential for users to be unaware of dangers lurking "under the hood" if they assume the eye-tracker introduces no errors in measuring infants' gaze. Moreover, the influx of voluminous…
Analyzing Virtual Physics Simulations with Tracker
ERIC Educational Resources Information Center
Claessens, Tom
2017-01-01
In the physics teaching community, Tracker is well known as a user-friendly open source video analysis software, authored by Douglas Brown. With this tool, the user can trace markers indicated on a video or on stroboscopic photos and perform kinematic analyses. Tracker also includes a data modeling tool that allows one to fit some theoretical…
Space Shuttle Star Tracker Challenges
NASA Technical Reports Server (NTRS)
Herrera, Linda M.
2010-01-01
The space shuttle fleet of avionics was originally designed in the 1970's. Many of the subsystems have been upgraded and replaced, however some original hardware continues to fly. Not only fly, but has proven to be the best design available to perform its designated task. The shuttle star tracker system is currently flying as a mixture of old and new designs, each with a unique purpose to fill for the mission. Orbiter missions have tackled many varied missions in space over the years. As the orbiters began flying to the International Space Station (ISS), new challenges were discovered and overcome as new trusses and modules were added. For the star tracker subsystem, the growing ISS posed an unusual problem, bright light. With two star trackers on board, the 1970's vintage image dissector tube (IDT) star trackers track the ISS, while the new solid state design is used for dim star tracking. This presentation focuses on the challenges and solutions used to ensure star trackers can complete the shuttle missions successfully. Topics include KSC team and industry partner methods used to correct pressurized case failures and track system performance.
NASA Technical Reports Server (NTRS)
2001-01-01
The Critical Viscosity of Xenon Experiment (CVX-2) on the STS-107 Research 1 mission in 2002 will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. The sample cell at the heart of CVX-2 will sit inside a thermostat providing three layers of insulation. The cell itself comprises a copper body that conducts heat efficiently and smoothes out thermal variations that that would destroy the xenon's uniformity. Inside the cell, the oscillating screen viscometer element is supported between two pairs of electrodes that deflect the screen and then measure screen motion.
2001-01-24
The Critical Viscosity of Xenon Experiment (CVX-2) on the STS-107 Research 1 mission in 2002 will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. The sample cell at the heart of CVX-2 will sit inside a thermostat providing three layers of insulation. The cell itself comprises a copper body that conducts heat efficiently and smoothes out thermal variations that that would destroy the xenon's uniformity. Inside the cell, the oscillating screen viscometer element is supported between two pairs of electrodes that deflect the screen and then measure screen motion.
A low-cost, CCD solid state star tracker
NASA Technical Reports Server (NTRS)
Chmielowski, M.; Wynne, D.
1992-01-01
Applied Research Corporation (ARC) has developed an engineering model of a multi-star CCD-based tracker for space applications requiring radiation hardness, high reliability and low power consumption. The engineering unit compared favorably in functional performance tests to the standard NASA single-star tracker. Characteristics of the ARC star tracker are: field of view = 10 deg x 7.5 deg, sensitivity range of -1 to +5 star magnitude, NEA = 3 in x 3 in, linearity = 5 in x 5 in, and power consumption of 1-3 W (operating mode dependent). The software is upgradable through a remote link. The hardware-limited acquisition rate is 1-5 Hz for stars of +2 to +5 magnitude and 10-30 Hz for -1 to +2 magnitude stars. Mechanical and electrical interfaces are identical to the standard NASA star tracker.
Chao, Yu-Ying; Chen, Yen-Ling; Lin, Hong-Yi; Huang, Yeou-Lih
2018-06-20
Thermal desorption electrospray ionization/mass spectrometry (TD-ESI-MS) employing a quickly interchangeable ionization source is a relatively new ambient ionization mass spectrometric technique that has had, to date, only a limited number of applications related to food safety control. With reallocation of resources, this direct-analysis technique has had wider use in food analysis when operated in dual-working mode (pretreatment-free qualitative screening and conventional quantitative confirmation) after switching to an ambient ionization source from a traditional atmospheric pressure ionization source. Herein, we describe the benefits and challenges associated with the use of a TD-ESI source to detect adulterants in processed vegetables (PVs), as a proof-of-concept for the detection of basic colorants. While TD-ESI can offer direct qualitative screening analyses for PVs with detection capabilities lower than those provided with liquid chromatography/UV detection within 30 s, the use of TD-ESI for semi-quantification is applicable only for homogeneous food matrices. Copyright © 2018 Elsevier B.V. All rights reserved.
Intelligent error correction method applied on an active pixel sensor based star tracker
NASA Astrophysics Data System (ADS)
Schmidt, Uwe
2005-10-01
Star trackers are opto-electronic sensors used on-board of satellites for the autonomous inertial attitude determination. During the last years star trackers became more and more important in the field of the attitude and orbit control system (AOCS) sensors. High performance star trackers are based up today on charge coupled device (CCD) optical camera heads. The active pixel sensor (APS) technology, introduced in the early 90-ties, allows now the beneficial replacement of CCD detectors by APS detectors with respect to performance, reliability, power, mass and cost. The company's heritage in star tracker design started in the early 80-ties with the launch of the worldwide first fully autonomous star tracker system ASTRO1 to the Russian MIR space station. Jena-Optronik recently developed an active pixel sensor based autonomous star tracker "ASTRO APS" as successor of the CCD based star tracker product series ASTRO1, ASTRO5, ASTRO10 and ASTRO15. Key features of the APS detector technology are, a true xy-address random access, the multiple windowing read out and the on-chip signal processing including the analogue to digital conversion. These features can be used for robust star tracking at high slew rates and under worse conditions like stray light and solar flare induced single event upsets. A special algorithm have been developed to manage the typical APS detector error contributors like fixed pattern noise (FPN), dark signal non-uniformity (DSNU) and white spots. The algorithm works fully autonomous and adapts to e.g. increasing DSNU and up-coming white spots automatically without ground maintenance or re-calibration. In contrast to conventional correction methods the described algorithm does not need calibration data memory like full image sized calibration data sets. The application of the presented algorithm managing the typical APS detector error contributors is a key element for the design of star trackers for long term satellite applications like geostationary telecom platforms.
Reliability and validity of ten consumer activity trackers.
Kooiman, Thea J M; Dontje, Manon L; Sprenger, Siska R; Krijnen, Wim P; van der Schans, Cees P; de Groot, Martijn
2015-01-01
Activity trackers can potentially stimulate users to increase their physical activity behavior. The aim of this study was to examine the reliability and validity of ten consumer activity trackers for measuring step count in both laboratory and free-living conditions. Healthy adult volunteers (n = 33) walked twice on a treadmill (4.8 km/h) for 30 min while wearing ten different activity trackers (i.e. Lumoback, Fitbit Flex, Jawbone Up, Nike+ Fuelband SE, Misfit Shine, Withings Pulse, Fitbit Zip, Omron HJ-203, Yamax Digiwalker SW-200 and Moves mobile application). In free-living conditions, 56 volunteers wore the same activity trackers for one working day. Test-retest reliability was analyzed with the Intraclass Correlation Coefficient (ICC). Validity was evaluated by comparing each tracker with the gold standard (Optogait system for laboratory and ActivPAL for free-living conditions), using paired samples t-tests, mean absolute percentage errors, correlations and Bland-Altman plots. Test-retest analysis revealed high reliability for most trackers except for the Omron (ICC .14), Moves app (ICC .37) and Nike+ Fuelband (ICC .53). The mean absolute percentage errors of the trackers in laboratory and free-living conditions respectively, were: Lumoback (-0.2, -0.4), Fibit Flex (-5.7, 3.7), Jawbone Up (-1.0, 1.4), Nike+ Fuelband (-18, -24), Misfit Shine (0.2, 1.1), Withings Pulse (-0.5, -7.9), Fitbit Zip (-0.3, 1.2), Omron (2.5, -0.4), Digiwalker (-1.2, -5.9), and Moves app (9.6, -37.6). Bland-Altman plots demonstrated that the limits of agreement varied from 46 steps (Fitbit Zip) to 2422 steps (Nike+ Fuelband) in the laboratory condition, and 866 steps (Fitbit Zip) to 5150 steps (Moves app) in the free-living condition. The reliability and validity of most trackers for measuring step count is good. The Fitbit Zip is the most valid whereas the reliability and validity of the Nike+ Fuelband is low.
Development of the FitSight Fitness Tracker to Increase Time Outdoors to Prevent Myopia.
Verkicharla, Pavan K; Ramamurthy, Dharani; Nguyen, Quang Duc; Zhang, Xinquan; Pu, Suan-Hui; Malhotra, Rahul; Ostbye, Truls; Lamoureux, Ecosse L; Saw, Seang-Mei
2017-06-01
To develop a fitness tracker (FitSight) to encourage children to increase time spent outdoors. To evaluate the wear pattern for this tracker and outdoor time pattern by estimating light illumination levels among children. The development of the FitSight fitness tracker involved the designing of two components: (1) the smartwatch with custom-made FitSight watch application (app) to log the instant light illuminance levels the wearer is exposed to, and (2) a companion smartphone app that synchronizes the time outdoors recorded by the smartwatch to smartphone via Bluetooth communication. Smartwatch wear patterns and tracker-recorded daily light illuminance levels data were gathered over 7 days from 23 Singapore children (mean ± standard deviation age: 9.2 ± 1.4 years). Feedback about the tracker was obtained from 14 parents using a three-level rating scale: very poor/poor/good. Of the 14 parents, 93% rated the complete "FitSight fitness tracker" as good and 64% rated its wearability as good. While 61% of 23 children wore the watch on all study days (i.e., 0 nonwear days), 26% had 1 nonwear day, and 4.5% children each had 3, 4, and 5 nonwear days, respectively. On average, children spent approximately 1 hour in light levels greater than 1000 lux on weekdays and 1.3 hours on weekends (60 ± 46 vs. 79 ± 53 minutes, P = 0.19). Mean number of outdoor "spurts" (light illuminance levels >1000 lux) per day was 8 ± 3 spurts with spurt duration of 34 ± 32 minutes. The FitSight tracker with its novel features may motivate children to increase time outdoors and play an important role in supplementing community outdoor programs to prevent myopia. If the developed noninvasive, wearable, smartwatch-based fitness tracker, FitSight, promotes daytime outdoor activity among children, it will be beneficial in addressing the epidemic of myopia.
High-efficiency thermal switch based on topological Josephson junctions
NASA Astrophysics Data System (ADS)
Sothmann, Björn; Giazotto, Francesco; Hankiewicz, Ewelina M.
2017-02-01
We propose theoretically a thermal switch operating by the magnetic-flux controlled diffraction of phase-coherent heat currents in a thermally biased Josephson junction based on a two-dimensional topological insulator. For short junctions, the system shows a sharp switching behavior while for long junctions the switching is smooth. Physically, the switching arises from the Doppler shift of the superconducting condensate due to screening currents induced by a magnetic flux. We suggest a possible experimental realization that exhibits a relative temperature change of 40% between the on and off state for realistic parameters. This is a factor of two larger than in recently realized thermal modulators based on conventional superconducting tunnel junctions.
Thermally Driven Electronic Topological Transition in FeTi
Yang, F. C.; Muñoz, J. A.; Hellman, O.; ...
2016-08-08
In this paper, ab initio molecular dynamics, supported by inelastic neutron scattering and nuclear resonant inelastic x-ray scattering, showed an anomalous thermal softening of the M 5 - phonon mode in B2-ordered FeTi that could not be explained by phonon-phonon interactions or electron-phonon interactions calculated at low temperatures. A computational investigation showed that the Fermi surface undergoes a novel thermally driven electronic topological transition, in which new features of the Fermi surface arise at elevated temperatures. Finally, the thermally induced electronic topological transition causes an increased electronic screening for the atom displacements in the M 5 - phonon mode andmore » an adiabatic electron-phonon interaction with an unusual temperature dependence.« less
NASA Astrophysics Data System (ADS)
Sun, T.; Institute of Hydrology; Water Resources
2011-12-01
An experimental evaluation of thermal and energy performance of temperate green roofs was carried out by thermal and meteorological observation and energy budget modeling using a setup of green roof in Beijing urban area. From both the yearly and daily temperature trends, the green roof could effectively damp down the undulation of roof surface temperature comparing with the conventional one. As an insulating screen, the green roof abated the amplitude of temperature by 9.0 in winter and 9.1 °C in summer, respectively. Under different cloud conditions, the green roof in summer time resulted in decreases in sensible heat and heat flux by 125.3W m-2 and 32.0 W m-2, respectively, on daily average comparing with the conventional one. Based on the energy budget analyses, under an assumptive scenario of 50% roof-greening in Beijing, a total of 34.1 PJ of sensible heat and 8.7 PJ of heat flux would be decreased for a summer period of 90 days. This study demonstrated that green roof, serving as an insulating screen to building top in comparison with the conventional roof, proved thermal improving effect in building scale and high energy saving potential for urban development.
2008-06-09
This is a photo of an engineering model of the Thermal and Evolved-Gas Analyzer TEGA instrument on board NASA Phoenix Mars Lander. This view shows a TEGA oven-loading mechanism beneath the input screen.
Measurement of in-plane thermal conductivity in polymer films
NASA Astrophysics Data System (ADS)
Wei, Qingshuo; Uehara, Chinatsu; Mukaida, Masakazu; Kirihara, Kazuhiro; Ishida, Takao
2016-04-01
Measuring the in-plane thermal conductivity of organic thermoelectric materials is challenging but is critically important. Here, a method to study the in-plane thermal conductivity of free-standing films (via the use of commercial equipment) based on temperature wave analysis is explored in depth. This subject method required a free-standing thin film with a thickness larger than 10 μm and an area larger than 1 cm2, which are not difficult to obtain for most solution-processable organic thermoelectric materials. We evaluated thermal conductivities and anisotropic ratios for various types of samples including insulating polymers, undoped semiconducting polymers, doped conducting polymers, and one-dimensional carbon fiber bulky papers. This approach facilitated a rapid screening of in-plane thermal conductivities for various organic thermoelectric materials.
Users' experiences of wearable activity trackers: a cross-sectional study.
Maher, Carol; Ryan, Jillian; Ambrosi, Christina; Edney, Sarah
2017-11-15
Wearable activity trackers offer considerable promise for helping users to adopt healthier lifestyles. This study aimed to explore users' experience of activity trackers, including usage patterns, sharing of data to social media, perceived behaviour change (physical activity, diet and sleep), and technical issues/barriers to use. A cross-sectional online survey was developed and administered to Australian adults who were current or former activity tracker users. Results were analysed descriptively, with differences between current and former users and wearable brands explored using independent samples t-tests, Mann-Whitney, and chi square tests. Participants included 200 current and 37 former activity tracker users (total N = 237) with a mean age of 33.1 years (SD 12.4, range 18-74 years). Fitbit (67.5%) and Garmin devices (16.5%) were most commonly reported. Participants typically used their trackers for sustained periods (5-7 months) and most intended to continue usage. Participants reported they had improved their physical activity (51-81%) more commonly than they had their diet (14-40%) or sleep (11-24%), and slightly more participants reported to value the real time feedback (89%) compared to the long-term monitoring (78%). Most users (70%) reported they had experienced functionality issues with their devices, most commonly related to battery life and technical difficulties. Results suggest users find activity trackers appealing and useful tools for increasing perceived physical activity levels over a sustained period.
Arba-Mosquera, Samuel; Aslanides, Ioannis M.
2012-01-01
Purpose To analyze the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery. Methods A comprehensive model, which directly considers eye movements, including saccades, vestibular, optokinetic, vergence, and miniature, as well as, eye-tracker acquisition rate, eye-tracker latency time, scanner positioning time, laser firing rate, and laser trigger delay have been developed. Results Eye-tracker acquisition rates below 100 Hz correspond to pulse positioning errors above 1.5 mm. Eye-tracker latency times to about 15 ms correspond to pulse positioning errors of up to 3.5 mm. Scanner positioning times to about 9 ms correspond to pulse positioning errors of up to 2 mm. Laser firing rates faster than eye-tracker acquisition rates basically duplicate pulse-positioning errors. Laser trigger delays to about 300 μs have minor to no impact on pulse-positioning errors. Conclusions The proposed model can be used for comparison of laser systems used for ablation processes. Due to the pseudo-random nature of eye movements, positioning errors of single pulses are much larger than observed decentrations in the clinical settings. There is no single parameter that ‘alone’ minimizes the positioning error. It is the optimal combination of the several parameters that minimizes the error. The results of this analysis are important to understand the limitations of correcting very irregular ablation patterns.
Collaborative engineering and design management for the Hobby-Eberly Telescope tracker upgrade
NASA Astrophysics Data System (ADS)
Mollison, Nicholas T.; Hayes, Richard J.; Good, John M.; Booth, John A.; Savage, Richard D.; Jackson, John R.; Rafal, Marc D.; Beno, Joseph H.
2010-07-01
The engineering and design of systems as complex as the Hobby-Eberly Telescope's* new tracker require that multiple tasks be executed in parallel and overlapping efforts. When the design of individual subsystems is distributed among multiple organizations, teams, and individuals, challenges can arise with respect to managing design productivity and coordinating successful collaborative exchanges. This paper focuses on design management issues and current practices for the tracker design portion of the Hobby-Eberly Telescope Wide Field Upgrade project. The scope of the tracker upgrade requires engineering contributions and input from numerous fields including optics, instrumentation, electromechanics, software controls engineering, and site-operations. Successful system-level integration of tracker subsystems and interfaces is critical to the telescope's ultimate performance in astronomical observation. Software and process controls for design information and workflow management have been implemented to assist the collaborative transfer of tracker design data. The tracker system architecture and selection of subsystem interfaces has also proven to be a determining factor in design task formulation and team communication needs. Interface controls and requirements change controls will be discussed, and critical team interactions are recounted (a group-participation Failure Modes and Effects Analysis [FMEA] is one of special interest). This paper will be of interest to engineers, designers, and managers engaging in multi-disciplinary and parallel engineering projects that require coordination among multiple individuals, teams, and organizations.
Parameter Identification Of Multilayer Thermal Insulation By Inverse Problems
NASA Astrophysics Data System (ADS)
Nenarokomov, Aleksey V.; Alifanov, Oleg M.; Gonzalez, Vivaldo M.
2012-07-01
The purpose of this paper is to introduce an iterative regularization method in the research of radiative and thermal properties of materials with further applications in the design of Thermal Control Systems (TCS) of spacecrafts. In this paper the radiative and thermal properties (heat capacity, emissivity and thermal conductance) of a multilayered thermal-insulating blanket (MLI), which is a screen-vacuum thermal insulation as a part of the (TCS) for perspective spacecrafts, are estimated. Properties of the materials under study are determined in the result of temperature and heat flux measurement data processing based on the solution of the Inverse Heat Transfer Problem (IHTP) technique. Given are physical and mathematical models of heat transfer processes in a specimen of the multilayered thermal-insulating blanket located in the experimental facility. A mathematical formulation of the IHTP, based on sensitivity function approach, is presented too. The practical testing was performed for specimen of the real MLI. This paper consists of recent researches, which developed the approach suggested at [1].
NASA Astrophysics Data System (ADS)
Yang, Dongxu; Zhang, Huifang; Liu, Yi; Chen, Baozhang; Cai, Zhaonan; Lü, Daren
2017-08-01
Monitoring atmospheric carbon dioxide (CO2) from space-borne state-of-the-art hyperspectral instruments can provide a high precision global dataset to improve carbon flux estimation and reduce the uncertainty of climate projection. Here, we introduce a carbon flux inversion system for estimating carbon flux with satellite measurements under the support of "The Strategic Priority Research Program of the Chinese Academy of Sciences—Climate Change: Carbon Budget and Relevant Issues". The carbon flux inversion system is composed of two separate parts: the Institute of Atmospheric Physics Carbon Dioxide Retrieval Algorithm for Satellite Remote Sensing (IAPCAS), and CarbonTracker-China (CT-China), developed at the Chinese Academy of Sciences. The Greenhouse gases Observing SATellite (GOSAT) measurements are used in the carbon flux inversion experiment. To improve the quality of the IAPCAS-GOSAT retrieval, we have developed a post-screening and bias correction method, resulting in 25%-30% of the data remaining after quality control. Based on these data, the seasonal variation of XCO2 (column-averaged CO2 dry-air mole fraction) is studied, and a strong relation with vegetation cover and population is identified. Then, the IAPCAS-GOSAT XCO2 product is used in carbon flux estimation by CT-China. The net ecosystem CO2 exchange is -0.34 Pg C yr-1 (±0.08 Pg C yr-1), with a large error reduction of 84%, which is a significant improvement on the error reduction when compared with in situ-only inversion.
Puri, Arjun; Kim, Ben; Nguyen, Olivier; Stolee, Paul; Tung, James
2017-01-01
Background Wearable activity trackers are newly emerging technologies with the anticipation for successfully supporting aging-in-place. Consumer-grade wearable activity trackers are increasingly ubiquitous in the market, but the attitudes toward, as well as acceptance and voluntary use of, these trackers in older population are poorly understood. Objective The aim of this study was to assess acceptance and usage of wearable activity trackers in Canadian community-dwelling older adults, using the potentially influential factors as identified in literature and technology acceptance model. Methods A mixed methods design was used. A total of 20 older adults aged 55 years and older were recruited from Southwestern Ontario. Participants used 2 different wearable activity trackers (Xiaomi Mi Band and Microsoft Band) separately for each segment in the crossover design study for 21 days (ie, 42 days total). A questionnaire was developed to capture acceptance and experience at the end of each segment, representing 2 different devices. Semistructured interviews were conducted with 4 participants, and a content analysis was performed. Results Participants ranged in age from 55 years to 84 years (mean age: 64 years). The Mi Band gained higher levels of acceptance (16/20, 80%) compared with the Microsoft Band (10/20, 50%). The equipment characteristics dimension scored significantly higher for the Mi Band (P<.05). The amount a participant was willing to pay for the device was highly associated with technology acceptance (P<.05). Multivariate logistic regression with 3 covariates resulted in an area under the curve of 0.79. Content analysis resulted in the formation of the following main themes: (1) smartphones as facilitators of wearable activity trackers; (2) privacy is less of a concern for wearable activity trackers, (3) value proposition: self-awareness and motivation; (4) subjective norm, social support, and sense of independence; and (5) equipment characteristics matter: display, battery, comfort, and aesthetics. Conclusions Older adults were mostly accepting of wearable activity trackers, and they had a clear understanding of its value for their lives. Wearable activity trackers were uniquely considered more personal than other types of technologies, thereby the equipment characteristics including comfort, aesthetics, and price had a significant impact on the acceptance. Results indicated that privacy was less of concern for older adults, but it may have stemmed from a lack of understanding of the privacy risks and implications. These findings add to emerging research that investigates acceptance and factors that may influence acceptance of wearable activity trackers among older adults. PMID:29141837
NASA Technical Reports Server (NTRS)
Arnold, J.; Dodson, J.; Laub, B.
1979-01-01
Subscale solid motor nozzles containing a baseline material or low cost materials to be considered as potential replacements for the baseline material are designed and tested. Data are presented from tests of four identically designed 2.5 inch throat diameter nozzles and one 7 inch throat diameter nozzle. The screening of new candidate low cost materials, as well as their thermophysical and thermochemical characterization is also discussed.
NASA Astrophysics Data System (ADS)
Sargent, Dusty; Chen, Chao-I.; Wang, Yuan-Fang
2010-02-01
The paper reports a fully-automated, cross-modality sensor data registration scheme between video and magnetic tracker data. This registration scheme is intended for use in computerized imaging systems to model the appearance, structure, and dimension of human anatomy in three dimensions (3D) from endoscopic videos, particularly colonoscopic videos, for cancer research and clinical practices. The proposed cross-modality calibration procedure operates this way: Before a colonoscopic procedure, the surgeon inserts a magnetic tracker into the working channel of the endoscope or otherwise fixes the tracker's position on the scope. The surgeon then maneuvers the scope-tracker assembly to view a checkerboard calibration pattern from a few different viewpoints for a few seconds. The calibration procedure is then completed, and the relative pose (translation and rotation) between the reference frames of the magnetic tracker and the scope is determined. During the colonoscopic procedure, the readings from the magnetic tracker are used to automatically deduce the pose (both position and orientation) of the scope's reference frame over time, without complicated image analysis. Knowing the scope movement over time then allows us to infer the 3D appearance and structure of the organs and tissues in the scene. While there are other well-established mechanisms for inferring the movement of the camera (scope) from images, they are often sensitive to mistakes in image analysis, error accumulation, and structure deformation. The proposed method using a magnetic tracker to establish the camera motion parameters thus provides a robust and efficient alternative for 3D model construction. Furthermore, the calibration procedure does not require special training nor use expensive calibration equipment (except for a camera calibration pattern-a checkerboard pattern-that can be printed on any laser or inkjet printer).
Czarnuch, Stephen; Mihailidis, Alex
2015-03-27
We present the development and evaluation of a robust hand tracker based on single overhead depth images for use in the COACH, an assistive technology for people with dementia. The new hand tracker was designed to overcome limitations experienced by the COACH in previous clinical trials. We train a random decision forest classifier using ∼5000 manually labeled, unbalanced, training images. Hand positions from the classifier are translated into task actions based on proximity to environmental objects. Tracker performance is evaluated using a large set of ∼24 000 manually labeled images captured from 41 participants in a fully-functional washroom, and compared to the system's previous colour-based hand tracker. Precision and recall were 0.994 and 0.938 for the depth tracker compared to 0.981 and 0.822 for the colour tracker with the current data, and 0.989 and 0.466 in the previous study. The improved tracking performance supports integration of the depth-based tracker into the COACH toward unsupervised, real-world trials. Implications for Rehabilitation The COACH is an intelligent assistive technology that can enable people with cognitive disabilities to stay at home longer, supporting the concept of aging-in-place. Automated prompting systems, a type of intelligent assistive technology, can help to support the independent completion of activities of daily living, increasing the independence of people with cognitive disabilities while reducing the burden of care experienced by caregivers. Robust motion tracking using depth imaging supports the development of intelligent assistive technologies like the COACH. Robust motion tracking also has application to other forms of assistive technologies including gaming, human-computer interaction and automated assessments.
Behavior Change Techniques Present in Wearable Activity Trackers: A Critical Analysis
Mercer, Kathryn; Li, Melissa; Giangregorio, Lora; Burns, Catherine
2016-01-01
Background Wearable activity trackers are promising as interventions that offer guidance and support for increasing physical activity and health-focused tracking. Most adults do not meet their recommended daily activity guidelines, and wearable fitness trackers are increasingly cited as having great potential to improve the physical activity levels of adults. Objective The objective of this study was to use the Coventry, Aberdeen, and London-Refined (CALO-RE) taxonomy to examine if the design of wearable activity trackers incorporates behavior change techniques (BCTs). A secondary objective was to critically analyze whether the BCTs present relate to known drivers of behavior change, such as self-efficacy, with the intention of extending applicability to older adults in addition to the overall population. Methods Wearing each device for a period of 1 week, two independent raters used CALO-RE taxonomy to code the BCTs of the seven wearable activity trackers available in Canada as of March 2014. These included Fitbit Flex, Misfit Shine, Withings Pulse, Jawbone UP24, Spark Activity Tracker by SparkPeople, Nike+ FuelBand SE, and Polar Loop. We calculated interrater reliability using Cohen's kappa. Results The average number of BCTs identified was 16.3/40. Withings Pulse had the highest number of BCTs and Misfit Shine had the lowest. Most techniques centered around self-monitoring and self-regulation, all of which have been associated with improved physical activity in older adults. Techniques related to planning and providing instructions were scarce. Conclusions Overall, wearable activity trackers contain several BCTs that have been shown to increase physical activity in older adults. Although more research and development must be done to fully understand the potential of wearables as health interventions, the current wearable trackers offer significant potential with regard to BCTs relevant to uptake by all populations, including older adults. PMID:27122452
Behavior Change Techniques Present in Wearable Activity Trackers: A Critical Analysis.
Mercer, Kathryn; Li, Melissa; Giangregorio, Lora; Burns, Catherine; Grindrod, Kelly
2016-04-27
Wearable activity trackers are promising as interventions that offer guidance and support for increasing physical activity and health-focused tracking. Most adults do not meet their recommended daily activity guidelines, and wearable fitness trackers are increasingly cited as having great potential to improve the physical activity levels of adults. The objective of this study was to use the Coventry, Aberdeen, and London-Refined (CALO-RE) taxonomy to examine if the design of wearable activity trackers incorporates behavior change techniques (BCTs). A secondary objective was to critically analyze whether the BCTs present relate to known drivers of behavior change, such as self-efficacy, with the intention of extending applicability to older adults in addition to the overall population. Wearing each device for a period of 1 week, two independent raters used CALO-RE taxonomy to code the BCTs of the seven wearable activity trackers available in Canada as of March 2014. These included Fitbit Flex, Misfit Shine, Withings Pulse, Jawbone UP24, Spark Activity Tracker by SparkPeople, Nike+ FuelBand SE, and Polar Loop. We calculated interrater reliability using Cohen's kappa. The average number of BCTs identified was 16.3/40. Withings Pulse had the highest number of BCTs and Misfit Shine had the lowest. Most techniques centered around self-monitoring and self-regulation, all of which have been associated with improved physical activity in older adults. Techniques related to planning and providing instructions were scarce. Overall, wearable activity trackers contain several BCTs that have been shown to increase physical activity in older adults. Although more research and development must be done to fully understand the potential of wearables as health interventions, the current wearable trackers offer significant potential with regard to BCTs relevant to uptake by all populations, including older adults.
Microinverter Thermal Performance in the Real-World: Measurements and Modeling
Hossain, Mohammad Akram; Xu, Yifan; Peshek, Timothy J.; Ji, Liang; Abramson, Alexis R.; French, Roger H.
2015-01-01
Real-world performance, durability and reliability of microinverters are critical concerns for microinverter-equipped photovoltaic systems. We conducted a data-driven study of the thermal performance of 24 new microinverters (Enphase M215) connected to 8 different brands of PV modules on dual-axis trackers at the Solar Durability and Lifetime Extension (SDLE) SunFarm at Case Western Reserve University, based on minute by minute power and thermal data from the microinverters and PV modules along with insolation and environmental data from July through October 2013. The analysis shows the strengths of the associations of microinverter temperature with ambient temperature, PV module temperature, irradiance and AC power of the PV systems. The importance of the covariates are rank ordered. A multiple regression model was developed and tested based on stable solar noon-time data, which gives both an overall function that predicts the temperature of microinverters under typical local conditions, and coefficients adjustments reecting refined prediction of the microinverter temperature connected to the 8 brands of PV modules in the study. The model allows for prediction of internal temperature for the Enphase M215 given similar climatic condition and can be expanded to predict microinverter temperature in fixed-rack and roof-top PV systems. This study is foundational in that similar models built on later stage data in the life of a device could reveal potential influencing factors in performance degradation. PMID:26147339
Radiative contribution to thermal conductance in animal furs and other woolly insulators.
Simonis, Priscilla; Rattal, Mourad; Oualim, El Mostafa; Mouhse, Azeddine; Vigneron, Jean-Pol
2014-01-27
This paper deals with radiation's contribution to thermal insulation. The mechanism by which a stack of absorbers limits radiative heat transfer is examined in detail both for black-body shields and grey-body shields. It shows that radiation energy transfer rates should be much faster than conduction rates. It demonstrates that, for opaque screens, increased reflectivity will dramatically reduce the rate of heat transfer, improving thermal insulation. This simple model is thought to contribute to the understanding of how animal furs, human clothes, rockwool insulators, thermo-protective containers, and many other passive energy-saving devices operate.
Hansson, P; Lindblom, U; Lindström, P
1991-01-01
Thermal sensibility was quantitatively assessed in the feet of 46 diabetic patients. In subjects with sensibility deficits the perception threshold for warmth or cold, or of heat pain, was either increased or lost. Four stages of impaired thermal sensibility were defined, and a classification of dysfunction is proposed which could be useful in routine clinical examination of patients with diabetic polyneuropathy. The classification of impaired thermal sensibility correlated significantly with the results of a bedside screening examination aimed at describing the severity of the polyneuropathy in terms of its regional extent. PMID:1880516
IMM tracking of a theater ballistic missile during boost phase
NASA Astrophysics Data System (ADS)
Hutchins, Robert G.; San Jose, Anthony
1998-09-01
Since the SCUD launches in the Gulf War, theater ballistic missile (TBM) systems have become a growing concern for the US military. Detection, tracking and engagement during boost phase or shortly after booster cutoff are goals that grow in importance with the proliferation of weapons of mass destruction. This paper addresses the performance of tracking algorithms for TBMs during boost phase and across the transition to ballistic flight. Three families of tracking algorithms are examined: alpha-beta-gamma trackers, Kalman-based trackers, and the interactive multiple model (IMM) tracker. In addition, a variation on the IMM to include prior knowledge of a booster cutoff parameter is examined. Simulated data is used to compare algorithms. Also, the IMM tracker is run on an actual ballistic missile trajectory. Results indicate that IMM trackers show significant advantage in tracking through the model transition represented by booster cutoff.
Robust object tacking based on self-adaptive search area
NASA Astrophysics Data System (ADS)
Dong, Taihang; Zhong, Sheng
2018-02-01
Discriminative correlation filter (DCF) based trackers have recently achieved excellent performance with great computational efficiency. However, DCF based trackers suffer boundary effects, which result in the unstable performance in challenging situations exhibiting fast motion. In this paper, we propose a novel method to mitigate this side-effect in DCF based trackers. We change the search area according to the prediction of target motion. When the object moves fast, broad search area could alleviate boundary effects and reserve the probability of locating object. When the object moves slowly, narrow search area could prevent effect of useless background information and improve computational efficiency to attain real-time performance. This strategy can impressively soothe boundary effects in situations exhibiting fast motion and motion blur, and it can be used in almost all DCF based trackers. The experiments on OTB benchmark show that the proposed framework improves the performance compared with the baseline trackers.
Sign-tracking predicts increased choice of cocaine over food in rats.
Tunstall, Brendan J; Kearns, David N
2015-03-15
The purpose of this study was to determine whether the tendency to sign-track to a food cue was predictive of rats' choice of cocaine over food. First, rats were trained on a procedure where insertion of a retractable lever was paired with food. A sub-group of rats - sign-trackers - primarily approached and contacted the lever, while another sub-group - goal-trackers - approached the site of food delivery. Rats were then trained on a choice task where they could choose between an infusion of cocaine (1.0 mg/kg) and a food pellet (45 mg). Sign-trackers chose cocaine over food significantly more often than did goal-trackers. These results support the incentive-salience theory of addiction and add to a growing number of studies which suggest that sign-trackers may model an addiction-prone phenotype. Copyright © 2014 Elsevier B.V. All rights reserved.
Mechanical stability of the CMS strip tracker measured with a laser alignment system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.
Here, the CMS tracker consists of 206 m 2 of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from –25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements ofmore » tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.« less
Mechanical stability of the CMS strip tracker measured with a laser alignment system
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; ...
2017-04-21
Here, the CMS tracker consists of 206 m 2 of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from –25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements ofmore » tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.« less
NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid
NASA Technical Reports Server (NTRS)
Wollen, Mark; Bakke, Victor; Baker, James
2012-01-01
While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.
Sharp Refractory Composite Leading Edges on Hypersonic Vehicles
NASA Technical Reports Server (NTRS)
Walker, Sandra P.; Sullivan, Brian J.
2003-01-01
On-going research of advanced sharp refractory composite leading edges for use on hypersonic air-breathing vehicles is presented in this paper. Intense magnitudes of heating and of heating gradients on the leading edge lead to thermal stresses that challenge the survivability of current material systems. A fundamental understanding of the problem is needed to further design development. Methodology for furthering the technology along with the use of advanced fiber architectures to improve the thermal-structural response is explored in the current work. Thermal and structural finite element analyses are conducted for several advanced fiber architectures of interest. A tailored thermal shock parameter for sharp orthotropic leading edges is identified for evaluating composite material systems. The use of the tailored thermal shock parameter has the potential to eliminate the need for detailed thermal-structural finite element analyses for initial screening of material systems being considered for a leading edge component.
NASA Technical Reports Server (NTRS)
Hausz, W.; Berkowitz, B. J.; Hare, R. C.
1978-01-01
Over forty thermal energy storage (TES) concepts gathered from the literature and personal contacts were studied for their suitability for the electric utility application of storing energy off-peak discharge during peak hours. Twelve selections were derived from the concepts for screening; they used as storage media high temperature water (HTW), hot oil, molten salts, and packed beds of solids such as rock. HTW required pressure containment by prestressed cast-iron or concrete vessels, or lined underground cavities. Both steam generation from storage and feedwater heating from storage were studied. Four choices were made for further study during the project. Economic comparison by electric utility standard cost practices, and near-term availability (low technical risk) were principal criteria but suitability for utility use, conservation potential, and environmental hazards were considered.
Adaptive Neural Star Tracker Calibration for Precision Spacecraft Pointing and Tracking
NASA Technical Reports Server (NTRS)
Bayard, David S.
1996-01-01
The Star Tracker is an essential sensor for precision pointing and tracking in most 3-axis stabilized spacecraft. In the interest (of) improving pointing performance by taking advantage of dramatic increases in flight computer power and memory anticipated over the next decade, this paper investigates the use of a neural net for adaptive in-flight calibration of the Star Tracker.
Improvement of Hungarian Joint Terminal Attack Program
2013-06-13
LST Laser Spot Tracker NVG Night Vision Goggle ROMAD Radio Operator Maintainer and Driver ROVER Remotely Operated Video Enhanced Receiver TACP...visual target designation. The other component consists of a laser spot tracker (LST), which identifies targets by tracking laser energy reflecting...capability for every type of night time missions, laser spot tracker for laser spot search missions, remotely operated video enhanced receiver
A survey of current solid state star tracker technology
NASA Astrophysics Data System (ADS)
Armstrong, R. W.; Staley, D. A.
1985-12-01
This paper is a survey of the current state of the art in design of star trackers for spacecraft attitude determination systems. Specific areas discussed are sensor technology, including the current state-of-the-art solid state sensors and techniques of mounting and cooling the sensor, analog image preprocessing electronics performance, and digital processing hardware and software. Three examples of area array solid state star tracker development are presented - ASTROS, developed by the Jet Propulsion Laboratory, the Retroreflector Field Tracker (RFT) by Ball Aerospace, and TRW's MADAN. Finally, a discussion of solid state line arrays explores the possibilities for one-dimensional imagers which offer simplified scan control electronics.
An accuracy measurement method for star trackers based on direct astronomic observation
Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping
2016-01-01
Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers. PMID:26948412
Exposure Time Optimization for Highly Dynamic Star Trackers
Wei, Xinguo; Tan, Wei; Li, Jian; Zhang, Guangjun
2014-01-01
Under highly dynamic conditions, the star-spots on the image sensor of a star tracker move across many pixels during the exposure time, which will reduce star detection sensitivity and increase star location errors. However, this kind of effect can be compensated well by setting an appropriate exposure time. This paper focuses on how exposure time affects the star tracker under highly dynamic conditions and how to determine the most appropriate exposure time for this case. Firstly, the effect of exposure time on star detection sensitivity is analyzed by establishing the dynamic star-spot imaging model. Then the star location error is deduced based on the error analysis of the sub-pixel centroiding algorithm. Combining these analyses, the effect of exposure time on attitude accuracy is finally determined. Some simulations are carried out to validate these effects, and the results show that there are different optimal exposure times for different angular velocities of a star tracker with a given configuration. In addition, the results of night sky experiments using a real star tracker agree with the simulation results. The summarized regularities in this paper should prove helpful in the system design and dynamic performance evaluation of the highly dynamic star trackers. PMID:24618776
An accuracy measurement method for star trackers based on direct astronomic observation.
Sun, Ting; Xing, Fei; Wang, Xiaochu; You, Zheng; Chu, Daping
2016-03-07
Star tracker is one of the most promising optical attitude measurement devices and it is widely used in spacecraft for its high accuracy. However, how to realize and verify such an accuracy remains a crucial but unsolved issue until now. The authenticity of the accuracy measurement method of a star tracker will eventually determine the satellite performance. A new and robust accuracy measurement method for a star tracker based on the direct astronomical observation is proposed here. In comparison with the conventional method with simulated stars, this method utilizes real navigation stars as observation targets which makes the measurement results more authoritative and authentic. Transformations between different coordinate systems are conducted on the account of the precision movements of the Earth, and the error curves of directional vectors are obtained along the three axes. Based on error analysis and accuracy definitions, a three-axis accuracy evaluation criterion has been proposed in this paper, which could determine pointing and rolling accuracy of a star tracker directly. Experimental measurements confirm that this method is effective and convenient to implement. Such a measurement environment is close to the in-orbit conditions and it can satisfy the stringent requirement for high-accuracy star trackers.
Analyzing Virtual Physics Simulations with Tracker
NASA Astrophysics Data System (ADS)
Claessens, Tom
2017-12-01
In the physics teaching community, Tracker is well known as a user-friendly open source video analysis software, authored by Douglas Brown. With this tool, the user can trace markers indicated on a video or on stroboscopic photos and perform kinematic analyses. Tracker also includes a data modeling tool that allows one to fit some theoretical equations of motion onto experimentally obtained data. In the field of particle mechanics, Tracker has been effectively used for learning and teaching about projectile motion, "toss up" and free-fall vertical motion, and to explain the principle of mechanical energy conservation. Also, Tracker has been successfully used in rigid body mechanics to interpret the results of experiments with rolling/slipping cylinders and moving rods. In this work, I propose an original method in which Tracker is used to analyze virtual computer simulations created with a physics-based motion solver, instead of analyzing video recording or stroboscopic photos. This could be an interesting approach to study kinematics and dynamics problems in physics education, in particular when there is no or limited access to physical labs. I demonstrate the working method with a typical (but quite challenging) problem in classical mechanics: a slipping/rolling cylinder on a rough surface.
TE-Tracker: systematic identification of transposition events through whole-genome resequencing.
Gilly, Arthur; Etcheverry, Mathilde; Madoui, Mohammed-Amin; Guy, Julie; Quadrana, Leandro; Alberti, Adriana; Martin, Antoine; Heitkam, Tony; Engelen, Stefan; Labadie, Karine; Le Pen, Jeremie; Wincker, Patrick; Colot, Vincent; Aury, Jean-Marc
2014-11-19
Transposable elements (TEs) are DNA sequences that are able to move from their location in the genome by cutting or copying themselves to another locus. As such, they are increasingly recognized as impacting all aspects of genome function. With the dramatic reduction in cost of DNA sequencing, it is now possible to resequence whole genomes in order to systematically characterize novel TE mobilization in a particular individual. However, this task is made difficult by the inherently repetitive nature of TE sequences, which in some eukaryotes compose over half of the genome sequence. Currently, only a few software tools dedicated to the detection of TE mobilization using next-generation-sequencing are described in the literature. They often target specific TEs for which annotation is available, and are only able to identify families of closely related TEs, rather than individual elements. We present TE-Tracker, a general and accurate computational method for the de-novo detection of germ line TE mobilization from re-sequenced genomes, as well as the identification of both their source and destination sequences. We compare our method with the two classes of existing software: specialized TE-detection tools and generic structural variant (SV) detection tools. We show that TE-Tracker, while working independently of any prior annotation, bridges the gap between these two approaches in terms of detection power. Indeed, its positive predictive value (PPV) is comparable to that of dedicated TE software while its sensitivity is typical of a generic SV detection tool. TE-Tracker demonstrates the benefit of adopting an annotation-independent, de novo approach for the detection of TE mobilization events. We use TE-Tracker to provide a comprehensive view of transposition events induced by loss of DNA methylation in Arabidopsis. TE-Tracker is freely available at http://www.genoscope.cns.fr/TE-Tracker . We show that TE-Tracker accurately detects both the source and destination of novel transposition events in re-sequenced genomes. Moreover, TE-Tracker is able to detect all potential donor sequences for a given insertion, and can identify the correct one among them. Furthermore, TE-Tracker produces significantly fewer false positives than common SV detection programs, thus greatly facilitating the detection and analysis of TE mobilization events.
NASA Technical Reports Server (NTRS)
Hockridge, R. R.
1973-01-01
Trade-off studies and screening evaluations were made of commercial polymers and silicone foam sheet stock. A low modulus, low density 0.26 gm/cc modification was developed of the GE-RESD PD-200 system based upon GE RTV-560 silicone polymer. The bond system modification was initially characterized for mechanical and thermal properties, evaluated for application methods, and its capability demonstrated as a strain arrestor bond system.
A graphite-lined regeneratively cooled thrust chamber
NASA Technical Reports Server (NTRS)
Stubbs, V. R.
1972-01-01
Design concepts, based on use of graphite as a thermal barrier for regeneratively cooled FLOX-methane thrust chambers, have been screened and concepts selected for detailed thermodynamic, stress, and fabrication analyses. A single design employing AGCarb-101, a fibrous graphite composite material, for a thermal barrier liner and an electroformed nickel structure with integral coolant passages was selected for fabrication and testing. The fabrication processes and the test results are described and illustrated.
Space Shuttle development update
NASA Technical Reports Server (NTRS)
Brand, V.
1984-01-01
The development efforts, since the STS-4 flight, in the Space Shuttle (SS) program are presented. The SS improvements introduced in the last two years include lower-weight loads, communication through the Tracking and Data Relay Satellite, expanded extravehicular activity capability, a maneuvering backpack and the manipulator foot restraint, the improvements in thermal projection system, the 'optional terminal area management targeting' guidance software, a rendezvous system with radar and star tracker sensors, and improved on-orbit living conditions. The flight demonstrations include advanced launch techniques (e.g., night launch and direct insertion to orbit); the on-orbit demonstrations; and added entry and launching capabilities. The entry aerodynamic analysis and entry flight control fine tuning are described. Reusability, improved ascent performance, intact abort and landing flexibility, rollout control, and 'smart speedbrakes' are among the many improvements planned for the future.
Shuttle infrared telescope facility (SIRTF) preliminary design study
NASA Technical Reports Server (NTRS)
1976-01-01
An overall picture of the SIRTF system is first presented, including the telescope, focal plane instruments, cryogen supply, shuttle and spacelab support subsystems, mechanical and data interfaces with the vehicles, ground support equipment, and system requirements. The optical, mechanical, and thermal characteristics of the telescope are then evaluated, followed by a description of the SIRTF internal stabilization subsystem and its interface with the IPS. Expected performance in the shuttle environment is considered. Tradeoff studies are described, including the Gregorian versus the Cassegrain telescope, aperture diameter tradeoff, a CCD versus an image dissector for the star tracker, the large ambient telescope versus the SIRTF, and a dedicated gimbal versus the IPS. Operations from integration through launch and recovery are also discussed and cost estimates for the program are presented.
Temperature dependence of attitude sensor coalignments on the Solar Maximum Mission (SMM)
NASA Technical Reports Server (NTRS)
Pitone, D. S.; Eudell, A. H.; Patt, F. S.
1990-01-01
The temperature correlation of the relative coalignment between the fine-pointing sun sensor and fixed-head star trackers measured on the Solar Maximum Mission (SMM) is analyzed. An overview of the SMM, including mission history and configuration, is given. Possible causes of the misalignment variation are discussed, with focus placed on spacecraft bending due to solar-radiation pressure, electronic or mechanical changes in the sensors, uncertainty in the attitude solutions, and mounting-plate expansion and contraction due to thermal effects. Yaw misalignment variation from the temperature profile is assessed, and suggestions for spacecraft operations are presented, involving methods to incorporate flight measurements of the temperature-versus-alignment function and its variance in operational procedures and the spacecraft structure temperatures in the attitude telemetry record.
A star tracker insensitive to stray light generated by radiation sources close to the field of view
NASA Astrophysics Data System (ADS)
Romoli, A.; Gambicorti, L.; Simonetti, F.; Zuccaro Marchi, A.
2017-11-01
Aim of this work is to propose an innovative star tracker, practically insensitive to the radiation coming from the sun or from other strong planetary sources out of (but near) the Field of View. These sources need to be stopped in some way. The classical solution to reject the unwanted radiation is to place a shadow (or baffle) before the star tracker objective. The shadow size depends on the Field of View and on the minimum angle subtended by the source (i.e. the sun) with respect to the optical axis of the star tracker. The lower is this angle the larger is the shadow. Requests for star trackers able to work with the sun as close as possible to the Field of View are increasing, due to the need of maximum mission flexibility. The innovation of this proposed star tracker is conceived by using spatial filtering with a concept complementary to that of coronagraph for sun corona observation, allowing to drastically reduce the size of the shadow. It can also work close to antennas and other part of the platform, which, when illuminated by the sun, become secondary sources capable to blind the star tracker. This kind of accommodation offers three main advantages: no cumbersome shadows (baffle), maximum flexibility in terms of mission profile, less platform location constraints. This new star sensor concept, dated 2007, is now patent pending. Galileo Avionica (now Selex Galileo) is the owner of the patent.
Flamarique, I; Santosh, P; Zuddas, A; Arango, C; Purper-Ouakil, D; Hoekstra, P J; Coghill, D; Schulze, U; Dittmann, R W; Buitelaar, J K; Lievesley, K; Frongia, R; Llorente, C; Méndez, I; Sala, R; Fiori, F; Castro-Fornieles, J
2016-12-13
To create a self-reported, internet-based questionnaire for the assessment of suicide risk in children and adolescents. As part of the EU project 'Suicidality: Treatment Occurring in Paediatrics' (STOP project), we developed web-based Patient Reported Outcome Measures (PROMs) for children and adolescents and for proxy reports by parents and clinicians in order to assess suicidality. Based on a literature review, expert panels and focus groups of patients, we developed the items of the STOP Suicidality Assessment Scale (STOP-SAS) in Spanish and English, translated it into four more languages, and optimized it for web-based presentation using the HealthTracker TM platform. Of the total 19 questions developed for the STOP-SAS, four questions that assess low-level suicidality were identified as screening questions (three of them for use with children, and all four for use with adolescents, parents and clinicians). A total of 395 adolescents, 110 children, 637 parents and 716 clinicians completed the questionnaire using the HealthTracker TM , allowing us to evaluate the internal consistency and convergent validity of the STOP-SAS with the clinician-rated Columbia Suicide Severity Rating Scale (C-SSRS). Validity was also assessed with the receiver operating characteristic (ROC) area of the STOP-SAS with the C-SSRS. The STOP-SAS comprises 19 items in its adolescent, parent, and clinician versions, and 14 items in its children's version. Good internal consistency was found for adolescents (Cronbach's alpha: 0.965), children (Cronbach's alpha: 0.922), parents (Cronbach's alpha: 0.951) and clinicians (Cronbach's alpha: 0.955) versions. A strong correlation was found between the STOP-SAS and the C-SSRS for adolescents (r:0.670), parents (r:0.548), clinicians (r:0.863) and children (r:0.654). The ROC area was good for clinicians' (0.917), adolescents' (0.834) and parents' (0.756) versions but only fair (0.683) for children's version. The STOP-SAS is a comprehensive, web-based PROM developed on the HealthTracker TM platform, and co-designed for use by adolescents, children, parents and clinicians. It allows the evaluation of aspects of suicidality and shows good reliability and validity.
NASA Astrophysics Data System (ADS)
Gumbs, Godfrey; Balassis, Antonios; Dahal, Dipendra; Lawrence Glasser, M.
2016-10-01
We compute and compare the effects due to a uniform perpendicular magnetic field as well as temperature on the static polarization functions for monolayer graphene (MLG), associated with the Dirac point, with that for the two-dimensional electron liquid (2DEL) with the use of comprehensive numerical calculations. The relevance of our study to the Friedel oscillations for the screening of the potential for a dilute distribution of impurities is reported too. Our results show substantial differences due to screening for the 2DEL and MLG which have not been given adequate attention previously.
SensibleSleep: A Bayesian Model for Learning Sleep Patterns from Smartphone Events
Sekara, Vedran; Jonsson, Håkan; Larsen, Jakob Eg; Lehmann, Sune
2017-01-01
We propose a Bayesian model for extracting sleep patterns from smartphone events. Our method is able to identify individuals’ daily sleep periods and their evolution over time, and provides an estimation of the probability of sleep and wake transitions. The model is fitted to more than 400 participants from two different datasets, and we verify the results against ground truth from dedicated armband sleep trackers. We show that the model is able to produce reliable sleep estimates with an accuracy of 0.89, both at the individual and at the collective level. Moreover the Bayesian model is able to quantify uncertainty and encode prior knowledge about sleep patterns. Compared with existing smartphone-based systems, our method requires only screen on/off events, and is therefore much less intrusive in terms of privacy and more battery-efficient. PMID:28076375
SensibleSleep: A Bayesian Model for Learning Sleep Patterns from Smartphone Events.
Cuttone, Andrea; Bækgaard, Per; Sekara, Vedran; Jonsson, Håkan; Larsen, Jakob Eg; Lehmann, Sune
2017-01-01
We propose a Bayesian model for extracting sleep patterns from smartphone events. Our method is able to identify individuals' daily sleep periods and their evolution over time, and provides an estimation of the probability of sleep and wake transitions. The model is fitted to more than 400 participants from two different datasets, and we verify the results against ground truth from dedicated armband sleep trackers. We show that the model is able to produce reliable sleep estimates with an accuracy of 0.89, both at the individual and at the collective level. Moreover the Bayesian model is able to quantify uncertainty and encode prior knowledge about sleep patterns. Compared with existing smartphone-based systems, our method requires only screen on/off events, and is therefore much less intrusive in terms of privacy and more battery-efficient.
Schwartzman, José Salomão; Velloso, Renata de Lima; D'Antino, Maria Eloísa Famá; Santos, Silvana
2015-05-01
To compare visual fixation at social stimuli in Rett syndrome (RT) and autism spectrum disorders (ASD) patients. Visual fixation at social stimuli was analyzed in 14 RS female patients (age range 4-30 years), 11 ASD male patients (age range 4-20 years), and 17 children with typical development (TD). Patients were exposed to three different pictures (two of human faces and one with social and non-social stimuli) presented for 8 seconds each on the screen of a computer attached to an eye-tracker equipment. Percentage of visual fixation at social stimuli was significantly higher in the RS group compared to ASD and even to TD groups. Visual fixation at social stimuli seems to be one more endophenotype making RS to be very different from ASD.
Tsai, Charlie; Lee, Kyoungjin; Yoo, Jong Suk; ...
2016-02-16
Density functional theory calculations are used to investigate thermal water decomposition over the close-packed (111), stepped (211), and open (100) facets of transition metal surfaces. A descriptor-based approach is used to determine that the (211) facet leads to the highest possible rates. As a result, a range of 96 binary alloys were screened for their potential activity and a rate control analysis was performed to assess how the overall rate could be improved.
Long-range electrostatic screening in ionic liquids
Gebbie, Matthew A.; Dobbs, Howard A.; Valtiner, Markus; Israelachvili, Jacob N.
2015-01-01
Electrolyte solutions with high concentrations of ions are prevalent in biological systems and energy storage technologies. Nevertheless, the high interaction free energy and long-range nature of electrostatic interactions makes the development of a general conceptual picture of concentrated electrolytes a significant challenge. In this work, we study ionic liquids, single-component liquids composed solely of ions, in an attempt to provide a novel perspective on electrostatic screening in very high concentration (nonideal) electrolytes. We use temperature-dependent surface force measurements to demonstrate that the long-range, exponentially decaying diffuse double-layer forces observed across ionic liquids exhibit a pronounced temperature dependence: Increasing the temperature decreases the measured exponential (Debye) decay length, implying an increase in the thermally driven effective free-ion concentration in the bulk ionic liquids. We use our quantitative results to propose a general model of long-range electrostatic screening in ionic liquids, where thermally activated charge fluctuations, either free ions or correlated domains (quasiparticles), take on the role of ions in traditional dilute electrolyte solutions. This picture represents a crucial step toward resolving several inconsistencies surrounding electrostatic screening and charge transport in ionic liquids that have impeded progress within the interdisciplinary ionic liquids community. More broadly, our work provides a previously unidentified way of envisioning highly concentrated electrolytes, with implications for diverse areas of inquiry, ranging from designing electrochemical devices to rationalizing electrostatic interactions in biological systems. PMID:26040001
Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC)
Han, Taewon; Mainelis, Gediminas
2017-01-01
Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10–30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods. PMID:28983124
Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC).
Han, Taewon; Mainelis, Gediminas
2017-05-01
Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10-30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods.
NASA Astrophysics Data System (ADS)
Reaungamornrat, S.; Otake, Y.; Uneri, A.; Schafer, S.; Mirota, D. J.; Nithiananthan, S.; Stayman, J. W.; Khanna, A. J.; Reh, D. D.; Gallia, G. L.; Taylor, R. H.; Siewerdsen, J. H.
2012-02-01
Conventional surgical tracking configurations carry a variety of limitations in line-of-sight, geometric accuracy, and mismatch with the surgeon's perspective (for video augmentation). With increasing utilization of mobile C-arms, particularly those allowing cone-beam CT (CBCT), there is opportunity to better integrate surgical trackers at bedside to address such limitations. This paper describes a tracker configuration in which the tracker is mounted directly on the Carm. To maintain registration within a dynamic coordinate system, a reference marker visible across the full C-arm rotation is implemented, and the "Tracker-on-C" configuration is shown to provide improved target registration error (TRE) over a conventional in-room setup - (0.9+/-0.4) mm vs (1.9+/-0.7) mm, respectively. The system also can generate digitally reconstructed radiographs (DRRs) from the perspective of a tracked tool ("x-ray flashlight"), the tracker, or the C-arm ("virtual fluoroscopy"), with geometric accuracy in virtual fluoroscopy of (0.4+/-0.2) mm. Using a video-based tracker, planning data and DRRs can be superimposed on the video scene from a natural perspective over the surgical field, with geometric accuracy (0.8+/-0.3) pixels for planning data overlay and (0.6+/-0.4) pixels for DRR overlay across all C-arm angles. The field-of-view of fluoroscopy or CBCT can also be overlaid on real-time video ("Virtual Field Light") to assist C-arm positioning. The fixed transformation between the x-ray image and tracker facilitated quick, accurate intraoperative registration. The workflow and precision associated with a variety of realistic surgical tasks were significantly improved using the Tracker-on-C - for example, nearly a factor of 2 reduction in time required for C-arm positioning, reduction or elimination of dose in "hunting" for a specific fluoroscopic view, and confident placement of the x-ray FOV on the surgical target. The proposed configuration streamlines the integration of C-arm CBCT with realtime tracking and demonstrated utility in a spectrum of image-guided interventions (e.g., spine surgery) benefiting from improved accuracy, enhanced visualization, and reduced radiation exposure.
A Bit of Fit: Minimalist Intervention in Adolescents Based on a Physical Activity Tracker
Gaudet, Jeffrey; Gallant, François
2017-01-01
Background Only 5% of Canadian youth meet the recommended 60 minutes of moderate to vigorous physical activity (MVPA) per day, with leisure time being increasingly allocated to technology usage. Direct-to-consumer mHealth devices that promote physical activity, such as wrist-worn physical activity trackers, have features with potential appeal to youth. Objective The primary purpose of this study was to determine whether a minimalist physical activity tracker-based intervention would lead to an increase in physical activity in young adolescents. A secondary aim of this study was to assess change in physical activity across a 7-week intervention, as measured by the tracker. Methods Using a quasi-experimental crossover design, two groups of 23 young adolescents (aged 13-14 years) were randomly assigned to immediate intervention or delayed intervention. The intervention consisted of wearing a Fitbit-Charge-HR physical activity tracker over a 7-week period. Actical accelerometers were used to measure participants’ levels of MVPA before and at the end of intervention periods for each group. Covariates such as age, sex, stage of change for physical activity behavior, and goal commitment were also measured. Results There was an increase in physical activity over the course of the study period, though it was not related to overall physical activity tracker use. An intervention response did, however, occur in a subset of participants. Specifically, exposure to the physical activity tracker was associated with an average daily increase in MVPA by more than 15 minutes (P=.01) among participants who reported being in the action and maintenance stages of behavior change in relation to participation in physical activity. Participants in the precontemplation, contemplation, and preparation stages of behavior change had no change in their level of MVPA (P=.81). Conclusions These results suggest that physical activity trackers may elicit improved physical activity related behavior in young adolescents demonstrating a readiness to be active. Future studies should seek to investigate if integrating physical activity trackers as part of more intensive interventions leads to greater increases in physical activity across different levels of stages of behavior change and if these changes can be sustained over longer periods of time. PMID:28684384
Optical Property Enhancement and Durability Evaluation of Heat Receiver Aperture Shield Materials
NASA Technical Reports Server (NTRS)
deGroh, Kim K.; Jaworske, Donald A.; Smith, Daniela C.
1998-01-01
Under the Solar Dynamic Flight Demonstration (SDFD) program, NASA Lewis Research Center worked with AlliedSignal Aerospace, the heat receiver contractor, on the development, characterization and durability testing of refractory metals to obtain appropriate optical and thermal properties for the SDFD heat receiver aperture shield. Molybdenum and tungsten foils were grit-blasted using silicon carbide or alumina grit under various grit-blasting conditions for optical property enhancement. Black rhenium coated tungsten foil was also evaluated. Tungsten, black rhenium-coated tungsten, and grit-blasted tungsten screens of various mesh sizes were placed over the pristine and grit-blasted foils for optical property characterization. Grit-blasting was found to be effective in decreasing the specular reflectance and the absorptance/emittance ratio of the refractory foils. The placement of a screen further enhanced these optical properties, with a grit-blasted screen over a grit-blasted foil producing the best results. Based on the optical property enhancement results, samples were tested for atomic oxygen and vacuum heat treatment durability. Grit-blasted (Al2O3 grit) 2 mil tungsten foil was chosen for the exterior layer of the SDFD heat receiver aperture shield. A 0.007 in. wire diameter, 20 x 20 mesh tungsten screen was chosen to cover the tungsten foil. Based on these test results, a heat receiver aperture shield test unit has been built with the screen covered grit-blast tungsten foil exterior layers. The aperture shield was tested and verified the thermal and structural durability of the outer foil layers during an off-pointing period.
COMDECOM: predicting the lifetime of screening compounds in DMSO solution.
Zitha-Bovens, Emrin; Maas, Peter; Wife, Dick; Tijhuis, Johan; Hu, Qian-Nan; Kleinöder, Thomas; Gasteiger, Johann
2009-06-01
The technological evolution of the 1990s in both combinatorial chemistry and high-throughput screening created the demand for rapid access to the compound deck to support the screening process. The common strategy within the pharmaceutical industry is to store the screening library in DMSO solution. Several studies have shown that a percentage of these compounds decompose in solution, varying from a few percent of the total to a substantial part of the library. In the COMDECOM (COMpound DECOMposition) project, the compound stability of screening compounds in DMSO solution is monitored in an accelerated thermal, hydrolytic, and oxidative decomposition program. A large database with stability data is collected, and from this database, a predictive model is being developed. The aim of this program is to build an algorithm that can flag compounds that are likely to decompose-information that is considered to be of utmost importance (e.g., in the compound acquisition process and when evaluation screening results of library compounds, as well as in the determination of optimal storage conditions).
On-Orbit Solar Dynamics Observatory (SDO) Star Tracker Warm Pixel Analysis
NASA Technical Reports Server (NTRS)
Felikson, Denis; Ekinci, Matthew; Hashmall, Joseph A.; Vess, Melissa
2011-01-01
This paper describes the process of identification and analysis of warm pixels in two autonomous star trackers on the Solar Dynamics Observatory (SDO) mission. A brief description of the mission orbit and attitude regimes is discussed and pertinent star tracker hardware specifications are given. Warm pixels are defined and the Quality Index parameter is introduced, which can be explained qualitatively as a manifestation of a possible warm pixel event. A description of the algorithm used to identify warm pixel candidates is given. Finally, analysis of dumps of on-orbit star tracker charge coupled devices (CCD) images is presented and an operational plan going forward is discussed. SDO, launched on February 11, 2010, is operated from the NASA Goddard Space Flight Center (GSFC). SDO is in a geosynchronous orbit with a 28.5 inclination. The nominal mission attitude points the spacecraft X-axis at the Sun, with the spacecraft Z-axis roughly aligned with the Solar North Pole. The spacecraft Y-axis completes the triad. In attitude, SDO moves approximately 0.04 per hour, mostly about the spacecraft Z-axis. The SDO star trackers, manufactured by Galileo Avionica, project the images of stars in their 16.4deg x 16.4deg fields-of-view onto CCD detectors consisting of 512 x 512 pixels. The trackers autonomously identify the star patterns and provide an attitude estimate. Each unit is able to track up to 9 stars. Additionally, each tracker calculates a parameter called the Quality Index, which is a measure of the quality of the attitude solution. Each pixel in the CCD measures the intensity of light and a warns pixel is defined as having a measurement consistently and significantly higher than the mean background intensity level. A warns pixel should also have lower intensity than a pixel containing a star image and will not move across the field of view as the attitude changes (as would a dim star image). It should be noted that the maximum error introduced in the star tracker attitude solution during suspected warm pixel corruptions is within the specified 36 attitude error budget requirement of [35, 70, 70] arcseconds. Thus, the star trackers provided attitude accuracy within the specification for SDO. The star tracker images are intentionally defocused so each star image is detected in more than one CCD pixel. The position of each star is calculated as an intensity-weighted average of the illuminated pixels. The exact method of finding the positions is proprietary to the tracker manufacturer. When a warm pixel happens to be in the vicinity of a star, it can corrupt the calculation of the position of that particular star, thereby corrupting the estimate of the attitude.
Puri, Arjun; Kim, Ben; Nguyen, Olivier; Stolee, Paul; Tung, James; Lee, Joon
2017-11-15
Wearable activity trackers are newly emerging technologies with the anticipation for successfully supporting aging-in-place. Consumer-grade wearable activity trackers are increasingly ubiquitous in the market, but the attitudes toward, as well as acceptance and voluntary use of, these trackers in older population are poorly understood. The aim of this study was to assess acceptance and usage of wearable activity trackers in Canadian community-dwelling older adults, using the potentially influential factors as identified in literature and technology acceptance model. A mixed methods design was used. A total of 20 older adults aged 55 years and older were recruited from Southwestern Ontario. Participants used 2 different wearable activity trackers (Xiaomi Mi Band and Microsoft Band) separately for each segment in the crossover design study for 21 days (ie, 42 days total). A questionnaire was developed to capture acceptance and experience at the end of each segment, representing 2 different devices. Semistructured interviews were conducted with 4 participants, and a content analysis was performed. Participants ranged in age from 55 years to 84 years (mean age: 64 years). The Mi Band gained higher levels of acceptance (16/20, 80%) compared with the Microsoft Band (10/20, 50%). The equipment characteristics dimension scored significantly higher for the Mi Band (P<.05). The amount a participant was willing to pay for the device was highly associated with technology acceptance (P<.05). Multivariate logistic regression with 3 covariates resulted in an area under the curve of 0.79. Content analysis resulted in the formation of the following main themes: (1) smartphones as facilitators of wearable activity trackers; (2) privacy is less of a concern for wearable activity trackers, (3) value proposition: self-awareness and motivation; (4) subjective norm, social support, and sense of independence; and (5) equipment characteristics matter: display, battery, comfort, and aesthetics. Older adults were mostly accepting of wearable activity trackers, and they had a clear understanding of its value for their lives. Wearable activity trackers were uniquely considered more personal than other types of technologies, thereby the equipment characteristics including comfort, aesthetics, and price had a significant impact on the acceptance. Results indicated that privacy was less of concern for older adults, but it may have stemmed from a lack of understanding of the privacy risks and implications. These findings add to emerging research that investigates acceptance and factors that may influence acceptance of wearable activity trackers among older adults. ©Arjun Puri, Ben Kim, Olivier Nguyen, Paul Stolee, James Tung, Joon Lee. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.11.2017.
Online Object Tracking, Learning and Parsing with And-Or Graphs.
Wu, Tianfu; Lu, Yang; Zhu, Song-Chun
2017-12-01
This paper presents a method, called AOGTracker, for simultaneously tracking, learning and parsing (TLP) of unknown objects in video sequences with a hierarchical and compositional And-Or graph (AOG) representation. The TLP method is formulated in the Bayesian framework with a spatial and a temporal dynamic programming (DP) algorithms inferring object bounding boxes on-the-fly. During online learning, the AOG is discriminatively learned using latent SVM [1] to account for appearance (e.g., lighting and partial occlusion) and structural (e.g., different poses and viewpoints) variations of a tracked object, as well as distractors (e.g., similar objects) in background. Three key issues in online inference and learning are addressed: (i) maintaining purity of positive and negative examples collected online, (ii) controling model complexity in latent structure learning, and (iii) identifying critical moments to re-learn the structure of AOG based on its intrackability. The intrackability measures uncertainty of an AOG based on its score maps in a frame. In experiments, our AOGTracker is tested on two popular tracking benchmarks with the same parameter setting: the TB-100/50/CVPR2013 benchmarks , [3] , and the VOT benchmarks [4] -VOT 2013, 2014, 2015 and TIR2015 (thermal imagery tracking). In the former, our AOGTracker outperforms state-of-the-art tracking algorithms including two trackers based on deep convolutional network [5] , [6] . In the latter, our AOGTracker outperforms all other trackers in VOT2013 and is comparable to the state-of-the-art methods in VOT2014, 2015 and TIR2015.
PROPOSAL FOR A SILICON VERTEX TRACKER (VTX) FOR THE PHENIX EXPERIMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
AKIBA,Y.
2004-10-01
We propose the construction of a Silicon Vertex Tracker (VTX) for the PHENIX experiment at RHIC. The VTX will substantially enhance the physics capabilities of the PHENIX central arm spectrometers. Our prime motivation is to provide precision measurements of heavy-quark production (charm and beauty) in A+A, p(d)+A, and polarized p+p collisions. These are key measurements for the future RHIC program, both for the heavy ion program as it moves from the discovery phase towards detailed investigation of the properties of the dense nuclear medium created in heavy ion collisions, and for the exploration of the nucleon spin-structure functions. In addition,more » the VTX will also considerably improve other measurements with PHENIX. The main physics topics addressed by the VTX are: (1) Hot and dense strongly interacting matter--(a) Potential enhancement of charm production, (b) Open beauty production, (c) Flavor dependence of jet quenching and QCD energy loss, (d) Accurate charm reference for quarkonium, (e) Thermal dilepton radiation, (f) High p{sub T} phenomena with light flavors above 10-15 GeV/c in p{sub T}, and (g) Upsilon spectroscopy in the e{sup +}e{sup -} decay channel. (2) Gluon spin structure of the nucleon--(a) {Delta}G/G with charm, (b) {Delta}G/G with beauty, and (c) x dependence of {Delta}G/G with {gamma}-jet correlations. (3) Nucleon structure in nuclei--Gluon shadowing over broad x-range.« less
Combinations of 148 navigation stars and the star tracker
NASA Technical Reports Server (NTRS)
Duncan, R.
1980-01-01
The angular separation of all star combinations for 148 nav star on the onboard software for space transportation system-3 flight and following missions is presented as well as the separation of each pair that satisfies the viewing constraints of using both star trackers simultaneously. Tables show (1) shuttle star catalog 1980 star position in M 1950 coordinates; (2) two star combination of 148 nav stars; and (3) summary of two star-combinations of the star tracker 5 deg filter. These 148 stars present 10,875 combinations. For the star tracker filters of plus or minus 5 deg, there are 875 combinations. Formalhaut (nav star 26) has the best number of combinations, which is 33.
Robust Visual Tracking Revisited: From Correlation Filter to Template Matching.
Liu, Fanghui; Gong, Chen; Huang, Xiaolin; Zhou, Tao; Yang, Jie; Tao, Dacheng
2018-06-01
In this paper, we propose a novel matching based tracker by investigating the relationship between template matching and the recent popular correlation filter based trackers (CFTs). Compared to the correlation operation in CFTs, a sophisticated similarity metric termed mutual buddies similarity is proposed to exploit the relationship of multiple reciprocal nearest neighbors for target matching. By doing so, our tracker obtains powerful discriminative ability on distinguishing target and background as demonstrated by both empirical and theoretical analyses. Besides, instead of utilizing single template with the improper updating scheme in CFTs, we design a novel online template updating strategy named memory, which aims to select a certain amount of representative and reliable tracking results in history to construct the current stable and expressive template set. This scheme is beneficial for the proposed tracker to comprehensively understand the target appearance variations, recall some stable results. Both qualitative and quantitative evaluations on two benchmarks suggest that the proposed tracking method performs favorably against some recently developed CFTs and other competitive trackers.
Chemoreception of hunger levels alters the following behaviour of a freshwater snail.
Larcher, Marie; Crane, Adam L
2015-12-01
Chemically-mediated orientation is essential for many animals that must locate sites containing resources such as mates or food. One way to find these areas is by using publically-available information from other individuals. We tested a freshwater snail, Physa gyrina, for chemoreception of conspecific cues and predicted they could discriminate between cues based on information regarding hunger levels. We placed 'tracker' snails into a 2-arm arena where they could either follow or avoid an area previously used by a 'marker' snail. The hunger levels of both trackers and markers was manipulated, being either starved or fed. Starved and fed trackers did not differ in their following response when markers were hungry, but starved trackers were significantly more likely to follow fed markers, compared to fed trackers that tended to avoid areas used by fed markers. This outcome suggests that P. gyrina uses conspecific chemical cues to find food and potentially in some situations to avoid intra-specific food competition. Copyright © 2015 Elsevier B.V. All rights reserved.
Star tracker operation in a high density proton field
NASA Technical Reports Server (NTRS)
Miklus, Kenneth J.; Kissh, Frank; Flynn, David J.
1993-01-01
Algorithms that reject transient signals due to proton effects on charge coupled device (CCD) sensors have been implemented in the HDOS ASTRA-l Star Trackers to be flown on the TOPEX mission scheduled for launch in July 1992. A unique technique for simulating a proton-rich environment to test trackers is described, as well as the test results obtained. Solar flares or an orbit that passes through the South Atlantic Anomaly can subject the vehicle to very high proton flux levels. There are three ways in which spurious proton generated signals can impact tracker performance: the many false signals can prevent or extend the time to acquire a star; a proton-generated signal can compromise the accuracy of the star's reported magnitude and position; and the tracked star can be lost, requiring reacquisition. Tests simulating a proton-rich environment were performed on two ASTRA-1 Star Trackers utilizing these new algorithms. There were no false acquisitions, no lost stars, and a significant reduction in reported position errors due to these improvements.
Optimum working fluids for solar powered Rankine cycle cooling of buildings
NASA Astrophysics Data System (ADS)
Wali, E.
1980-01-01
A number of fluids were screened for their operational reliability and thermal stability as working fluids for domestic solar Rankine cycle cooling. The results indicate that the halogenated compound R-113, followed by the fluorinated compound FC-88, is best suited for safe Rankine cycle operation. Further dynamic investigations are, however, needed to study the thermal stability of these fluids in the presence and absence of lubricants in copper, steel, and alloy conduits
2012-12-01
photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase... photovoltaic (PV) system to use a maximum power point tracker ( MPPT ) to increase the power output of the solar array. Currently, most military... MPPT ) is an optimizing circuit that is used in conjunction with photovoltaic (PV) arrays to achieve the maximum delivery of power from the array
A Methodology to Analyze Photovoltaic Tracker Uptime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muller, Matthew T; Ruth, Dan
A metric is developed to analyze the daily performance of single-axis photovoltaic (PV) trackers. The metric relies on comparing correlations between the daily time series of the PV power output and an array of simulated plane-of-array irradiances for the given day. Mathematical thresholds and a logic sequence are presented, so the daily tracking metric can be applied in an automated fashion on large-scale PV systems. The results of applying the metric are visually examined against the time series of the power output data for a large number of days and for various systems. The visual inspection results suggest that overall,more » the algorithm is accurate in identifying stuck or functioning trackers on clear-sky days. Visual inspection also shows that there are days that are not classified by the metric where the power output data may be sufficient to identify a stuck tracker. Based on the daily tracking metric, uptime results are calculated for 83 different inverters at 34 PV sites. The mean tracker uptime is calculated at 99% based on 2 different calculation methods. The daily tracking metric clearly has limitations, but as there is no existing metrics in the literature, it provides a valuable tool for flagging stuck trackers.« less
Serchi, V; Peruzzi, A; Cereatti, A; Della Croce, U
2016-01-01
The knowledge of the visual strategies adopted while walking in cognitively engaging environments is extremely valuable. Analyzing gaze when a treadmill and a virtual reality environment are used as motor rehabilitation tools is therefore critical. Being completely unobtrusive, remote eye-trackers are the most appropriate way to measure the point of gaze. Still, the point of gaze measurements are affected by experimental conditions such as head range of motion and visual stimuli. This study assesses the usability limits and measurement reliability of a remote eye-tracker during treadmill walking while visual stimuli are projected. During treadmill walking, the head remained within the remote eye-tracker workspace. Generally, the quality of the point of gaze measurements declined as the distance from the remote eye-tracker increased and data loss occurred for large gaze angles. The stimulus location (a dot-target) did not influence the point of gaze accuracy, precision, and trackability during both standing and walking. Similar results were obtained when the dot-target was replaced by a static or moving 2D target and "region of interest" analysis was applied. These findings foster the feasibility of the use of a remote eye-tracker for the analysis of gaze during treadmill walking in virtual reality environments.
Kanstrup, Anne Marie; Bertelsen, Pernille; Jensen, Martin B
2018-01-01
Activity trackers are designed to support individuals in monitoring and increasing their physical activity. The use of activity trackers among individuals diagnosed with depression and anxiety has not yet been examined. This pilot study investigates how this target group engages with an activity tracker during a 10-week health intervention aimed to increase their physical activity level and improve their physical and mental health. Two groups of 11 young adults (aged 18-29 years) diagnosed with depression or anxiety participated in the digital health intervention. The study used mixed methods to investigate the research question. Quantitative health data were used to assess the intervention's influence on the participants' health and qualitative data provided insights into the participants' digital health experience. The study demonstrated an ambiguous influence from the use of an activity tracker with positive physical and mental health results, but a fading and even negative digital health engagement and counterproductive competition. The ambiguous results identify a need for (1) developing strategies for health professionals to provide supervised use of activity trackers and support the target groups' abilities to convert health information about physical activity into positive health strategies, and (2) designing alternatives for health promoting IT targeted users who face challenges and need motivation beyond self-tracking and competition.
Star Tracker Performance Estimate with IMU
NASA Technical Reports Server (NTRS)
Aretskin-Hariton, Eliot D.; Swank, Aaron J.
2015-01-01
A software tool for estimating cross-boresight error of a star tracker combined with an inertial measurement unit (IMU) was developed to support trade studies for the Integrated Radio and Optical Communication project (iROC) at the National Aeronautics and Space Administration Glenn Research Center. Typical laser communication systems, such as the Lunar Laser Communication Demonstration (LLCD) and the Laser Communication Relay Demonstration (LCRD), use a beacon to locate ground stations. iROC is investigating the use of beaconless precision laser pointing to enable laser communication at Mars orbits and beyond. Precision attitude knowledge is essential to the iROC mission to enable high-speed steering of the optical link. The preliminary concept to achieve this precision attitude knowledge is to use star trackers combined with an IMU. The Star Tracker Accuracy (STAcc) software was developed to rapidly assess the capabilities of star tracker and IMU configurations. STAcc determines the overall cross-boresight error of a star tracker with an IMU given the characteristic parameters: quantum efficiency, aperture, apparent star magnitude, exposure time, field of view, photon spread, detector pixels, spacecraft slew rate, maximum stars used for quaternion estimation, and IMU angular random walk. This paper discusses the supporting theory used to construct STAcc, verification of the program and sample results.
Pineros, Oscar E
2002-01-01
Eye tracker systems have been developed concomitantly with small scanning beams to theoretically reduce ablation zone decentration and for accurate registration of all the laser pulses on the cornea. The purpose of the study was to compare the tracker-assisted with the manual centration method. Twenty-five patients (48 eyes) with myopia and/or astigmatism had laser in situ keratomileusis (LASIK) between August 1998 and February 1999 with the Technolas 117C laser. Twenty patients (38 eyes, 80%) were available for follow-up at 3 months after surgery. Eyes were assigned randomly to one of two ablation zone centration methods: Group 1: Tracker-assisted (20 eyes), Group 2: Manual (18 eyes). Mean distance between the ablation zone center and the pupillary center in the tracker-assisted centration group was 0.55 +/- 0.30 mm (range, 0.10 to 1.4 mm), and in the manual centration group, 0.43 +/- 0.23 mm (range, 0.10 to 1.0 mm) (P = .177). There was no statistically significant difference in postoperative contrast sensitivity, glare, and Topographical Corneal Surface Regularity Index (SRI) between the two groups. We obtained good results with both centration methods. We did not find superiority of the tracker-assisted over manual regarding ablation zone centration, vision quality, or regularity of the ablation.
The James Webb Space Telescope
NASA Technical Reports Server (NTRS)
Nowak, Maria; Eichorn, William; Hill, Michael; Hylan, Jason; Marsh, James; Ohl, Raymond; Sampler, Henry; Wright, Geraldine; Crane, Allen; Herrera, Acey;
2007-01-01
The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approx.40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISIM optical metering structure is a roughly 2.2x1.7x2.2mY, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISM structure must meet its requirements at the approx.40K cryogenic operating temperature. The SIs are aligned to the structure s coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified.
NASA Astrophysics Data System (ADS)
Kaplan, Herbert
1988-01-01
Based on encouraging results on the Army's programs for infrared mass screening of printed circuit boards at the depot level, the US Army CECOM (Communication-Electronics Command) undertook a one-year investigation of the applicability of similar techniques to screening and diagnostics of mechanical assemblies. These included tanks, helicopters, transport vehicles and their major subassemblies (transmissions, engines, axles, etc.) at field and depot levels. Honeyhill Technical Company was tasked to classify candidate assemblies and perform preliminary measurements using Army-owned general-purpose thermal imaging equipment. The investigations yielded positive results, and it was decided to pursue a comprehensive measurements program using field-mobile equipment specifically procured for the program. This paper summarizes the results of the investigations, outlines the measurements techniques utilized, describes the classification and selection of candidate assemblies, and reports on progress toward the goals of the program.
NASA Technical Reports Server (NTRS)
Wilkinson, W. H.; Kirkhart, F. P.; Kistler, C. W.; Duckworth, W. H.; Ungar, E. W.; Foster, E. L.
1970-01-01
Technical problems of design and flight qualification of the proposed classes of surface insulation materials and leading edge materials were reviewed. A screening test plan, a preliminary design data test plan and a design data test plan were outlined. This program defined the apparent critical differences between the surface insulators and the leading edge materials, structuring specialized screening test plans for each of these two classes of materials. Unique testing techniques were shown to be important in evaluating the structural interaction aspects of the surface insulators and a separate task was defined to validate the test plan. In addition, a compilation was made of available information on proposed material (including metallic TPS), previous shuttle programs, pertinent test procedures, and other national programs of merit. This material was collected and summarized in an informally structured workbook.
NASA Astrophysics Data System (ADS)
Refat, Moamen S.
2013-03-01
Complexes of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with curcumin ligand as antitumor activity were synthesized and characterized by elemental analysis, conductometry, magnetic susceptibility, UV-Vis, IR, Raman, ESR, 1H-NMR spectroscopy, X-ray diffraction analysis of powdered samples and thermal analysis, and screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as a monobasic bidentate ligand towards the central metal ion with an oxygen's donor atoms sequence of both sbnd OH and Cdbnd O groups under keto-enol structure. From the microanalytical data, the stoichiometry of the complexes 1:2 (metal:ligand) was found. The ligand and their metal complexes were screened for antibacterial activity against Escherichia Coli, Staphylococcus aureus, Bacillus subtilis and Pseudomonas aeruginosa and fungicidal activity against Aspergillus flavus and Candida albicans.
Dwivedi, S; Srivastava, S; Mishra, S; Dixit, B; Kumar, A; Tripathi, R D
2008-10-30
The present investigation was carried out to screen native plants growing in fly-ash (FA) contaminated areas near National Thermal Power Corporation, Tanda, Uttar Pradesh, India with a view to using them for the eco-restoration of the area. A total number of 17 plants (9 aquatic, 6 terrestrial and 2 algal species) were collected and screened for heavy metal (Fe, Zn, Cu, Mo, B, Si, Al, Cr, Pb, Cd, Hg and As) accumulation. Differential accumulation of various heavy metals by different species of plants was observed. Hydrilla verticillata was found to be the most efficient metal accumulator among 9 aquatic plants, Eclipta alba among 6 terrestrial plants and Phormedium papyraceum between 2 algal species. In general, the maximum levels of most metals were found in terrestrial plants while the lowest in algal species. However, translocation of the metals from root to shoot was found to be higher in aquatic plants than terrestrial ones. These results suggest that various aquatic, terrestrial and algal species of plants may be used in a synergistic way to remediate and restore the FA contaminated areas.
NASA Technical Reports Server (NTRS)
Bailey, P. G.
1977-01-01
Oxide-Dispersion-strengthened (ODS) Ni-Cr-Al alloy systems were exploited for turbine engine vanes which would be used for the space shuttle thermal protection system. Available commercial and developmental advanced ODS alloys were evaluated, and three were selected based on established vane property goals and manufacturing criteria. The selected alloys were evaluated in an engine test. Candidate alloys were screened by strength, thermal fatigue resistance, oxidation and sulfidation resistance. The Ni-16Cr (3 to 5)Al-ThO2 system was identified as having attractive high temperature oxidation resistance. Subsequent work also indicated exceptional sulfidation resistance for these alloys.
Distributed databases for materials study of thermo-kinetic properties
NASA Astrophysics Data System (ADS)
Toher, Cormac
2015-03-01
High-throughput computational materials science provides researchers with the opportunity to rapidly generate large databases of materials properties. To rapidly add thermal properties to the AFLOWLIB consortium and Materials Project repositories, we have implemented an automated quasi-harmonic Debye model, the Automatic GIBBS Library (AGL). This enables us to screen thousands of materials for thermal conductivity, bulk modulus, thermal expansion and related properties. The search and sort functions of the online database can then be used to identify suitable materials for more in-depth study using more precise computational or experimental techniques. AFLOW-AGL source code is public domain and will soon be released within the GNU-GPL license.
Using CarbonTracker carbon flux estimates to improve a terrestrial carbon cycle model
NASA Astrophysics Data System (ADS)
Peters, W.; Krol, M.; Miller, J. B.; Tans, P. P.; Carvalhais, N.; Schaefer, K.
2009-12-01
Estimates of net ecosystem exchange (NEE) from NOAA’s CarbonTracker CO2 data assimilation system show patterns of annual net uptake not represented in most terrestrial carbon cycle models. This is mainly because such models lack information on the land-use history of individual ecosystems, which is the main driver of long-term mean carbon exchange. Instead, they assume the biosphere to be in steady-state, with annual gross photosynthesis equalling ecosystem respiration everywhere. This limits their use in interpreting observations of carbon dynamics such as with eddy-covariance techniques or through atmospheric CO2 records. We have implemented a method that takes the long-term mean NEE estimates from CarbonTracker to derive the size of the dominant carbon pool in each ecosystem of the SIBCASA biosphere model. With the new pool sizes, the SIBCASA model is no longer in steady-state and reproduces annual carbon uptake patterns from CarbonTracker. We will show that the non steady-state SIBCASA model is not only much more consistent with the atmospheric CO2 record, but also with independent data on standing wood biomass and forest age from the Forest Inventory and Analysis (FIA) Program of the U.S. Forest Service. Four years of CarbonTracker NEE are needed to reliably derive a long term mean for this process, and we use three other years from CarbonTracker to evaluate the non steady state SIBCASA NEE. We will furthermore show that the non steady-state SIBCASA NEE is a much better first-guess for the CarbonTracker data assimilation process, allowing more confidence in its final NEE estimate, and reducing a systematic bias in CarbonTracker modeled atmospheric CO2. This overcomes a long standing issue in inverse modeling, and opens the way for further assessment and improvement of carbon cycle models such as SIBCASA.
Youth Oriented Activity Trackers: Comprehensive Laboratory- and Field-Based Validation
2017-01-01
Background Commercial activity trackers are growing in popularity among adults and some are beginning to be marketed to children. There is, however, a paucity of independent research examining the validity of these devices to detect physical activity of different intensity levels. Objectives The purpose of this study was to determine the validity of the output from 3 commercial youth-oriented activity trackers in 3 phases: (1) orbital shaker, (2) structured indoor activities, and (3) 4 days of free-living activity. Methods Four units of each activity tracker (Movband [MB], Sqord [SQ], and Zamzee [ZZ]) were tested in an orbital shaker for 5-minutes at three frequencies (1.3, 1.9, and 2.5 Hz). Participants for Phase 2 (N=14) and Phase 3 (N=16) were 6-12 year old children (50% male). For Phase 2, participants completed 9 structured activities while wearing each tracker, the ActiGraph GT3X+ (AG) research accelerometer, and a portable indirect calorimetry system to assess energy expenditure (EE). For Phase 3, participants wore all 4 devices for 4 consecutive days. Correlation coefficients, linear models, and non-parametric statistics evaluated the criterion and construct validity of the activity tracker output. Results Output from all devices was significantly associated with oscillation frequency (r=.92-.99). During Phase 2, MB and ZZ only differentiated sedentary from light intensity (P<.01), whereas the SQ significantly differentiated among all intensity categories (all comparisons P<.01), similar to AG and EE. During Phase 3, AG counts were significantly associated with activity tracker output (r=.76, .86, and .59 for the MB, SQ, and ZZ, respectively). Conclusions Across study phases, the SQ demonstrated stronger validity than the MB and ZZ. The validity of youth-oriented activity trackers may directly impact their effectiveness as behavior modification tools, demonstrating a need for more research on such devices. PMID:28724509
Nelson, Sandahl H; Weiner, Lauren S
2018-01-01
Background There has been a rapid increase in the use of technology-based activity trackers to promote behavior change. However, little is known about how individuals use these trackers on a day-to-day basis or how tracker use relates to increasing physical activity. Objective The aims were to use minute level data collected from a Fitbit tracker throughout a physical activity intervention to examine patterns of Fitbit use and activity and their relationships with success in the intervention based on ActiGraph-measured moderate to vigorous physical activity (MVPA). Methods Participants included 42 female breast cancer survivors randomized to the physical activity intervention arm of a 12-week randomized controlled trial. The Fitbit One was worn daily throughout the 12-week intervention. ActiGraph GT3X+ accelerometer was worn for 7 days at baseline (prerandomization) and end of intervention (week 12). Self-reported frequency of looking at activity data on the Fitbit tracker and app or website was collected at week 12. Results Adherence to wearing the Fitbit was high and stable, with a mean of 88.13% of valid days over 12 weeks (SD 14.49%). Greater adherence to wearing the Fitbit was associated with greater increases in ActiGraph-measured MVPA (binteraction=0.35, P<.001). Participants averaged 182.6 minutes/week (SD 143.9) of MVPA on the Fitbit, with significant variation in MVPA over the 12 weeks (F=1.91, P=.04). The majority (68%, 27/40) of participants reported looking at their tracker or looking at the Fitbit app or website once a day or more. Changes in Actigraph-measured MVPA were associated with frequency of looking at one’s data on the tracker (b=−1.36, P=.07) but not significantly associated with frequency of looking at one’s data on the app or website (P=.36). Conclusions This is one of the first studies to explore the relationship between use of a commercially available activity tracker and success in a physical activity intervention. A deeper understanding of how individuals engage with technology-based trackers may enable us to more effectively use these types of trackers to promote behavior change. Trial Registration ClinicalTrials.gov NCT02332876; https://clinicaltrials.gov/ct2/show/NCT02332876?term=NCT02332876 &rank=1 (Archived by WebCite at http://www.webcitation.org/6wplEeg8i). PMID:29402761
Hartman, Sheri J; Nelson, Sandahl H; Weiner, Lauren S
2018-02-05
There has been a rapid increase in the use of technology-based activity trackers to promote behavior change. However, little is known about how individuals use these trackers on a day-to-day basis or how tracker use relates to increasing physical activity. The aims were to use minute level data collected from a Fitbit tracker throughout a physical activity intervention to examine patterns of Fitbit use and activity and their relationships with success in the intervention based on ActiGraph-measured moderate to vigorous physical activity (MVPA). Participants included 42 female breast cancer survivors randomized to the physical activity intervention arm of a 12-week randomized controlled trial. The Fitbit One was worn daily throughout the 12-week intervention. ActiGraph GT3X+ accelerometer was worn for 7 days at baseline (prerandomization) and end of intervention (week 12). Self-reported frequency of looking at activity data on the Fitbit tracker and app or website was collected at week 12. Adherence to wearing the Fitbit was high and stable, with a mean of 88.13% of valid days over 12 weeks (SD 14.49%). Greater adherence to wearing the Fitbit was associated with greater increases in ActiGraph-measured MVPA (b interaction =0.35, P<.001). Participants averaged 182.6 minutes/week (SD 143.9) of MVPA on the Fitbit, with significant variation in MVPA over the 12 weeks (F=1.91, P=.04). The majority (68%, 27/40) of participants reported looking at their tracker or looking at the Fitbit app or website once a day or more. Changes in Actigraph-measured MVPA were associated with frequency of looking at one's data on the tracker (b=-1.36, P=.07) but not significantly associated with frequency of looking at one's data on the app or website (P=.36). This is one of the first studies to explore the relationship between use of a commercially available activity tracker and success in a physical activity intervention. A deeper understanding of how individuals engage with technology-based trackers may enable us to more effectively use these types of trackers to promote behavior change. ClinicalTrials.gov NCT02332876; https://clinicaltrials.gov/ct2/show/NCT02332876?term=NCT02332876 &rank=1 (Archived by WebCite at http://www.webcitation.org/6wplEeg8i). ©Sheri J Hartman, Sandahl H Nelson, Lauren S Weiner. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.02.2018.
Breadboard stellar tracker system test report, volume 2
NASA Technical Reports Server (NTRS)
1981-01-01
Complete data from a test program designed to evaluate the performance of a star tracker, a breadboard tracker system, is presented in tabular form. All data presented was normalized to the pixel dimension of 20 micrometers. Data from determination of maximum spatial noise as it applies to the coarse and fine acquisition modes is presented. Pointing accuracy test data, raw pixel data for the track cycle, and data from equipment related tests is also presented.
S-band range tracker and Surveillance Lab interface
NASA Astrophysics Data System (ADS)
Bush, B. D.
1983-09-01
This report documents the design, construction, test and laboratory integration of the range tracker and associated subsystems for the RADC/OC Surveillance Laboratory's S-Band tracking radar. This development was accomplished over the period from December 1981 to November 1983 and was designed, constructed and tested entirely in-house. This report contains information on the use of the range tracker, its interfaces to other laboratory equipment, the philosophy behind its design, the detailed design of the hardware (including schematics, timing and cabling diagrams), the detailed software design (including flowcharts), and the mathematical description of its algorithms. The range tracker will be used in conjunction with other equipment in the OC Surveillance Lab in the taking and recording of radar data during flight tests.
Reduction of low frequency error for SED36 and APS based HYDRA star trackers
NASA Astrophysics Data System (ADS)
Ouaknine, Julien; Blarre, Ludovic; Oddos-Marcel, Lionel; Montel, Johan; Julio, Jean-Marc
2017-11-01
In the frame of the CNES Pleiades satellite, a reduction of the star tracker low frequency error, which is the most penalizing error for the satellite attitude control, was performed. For that purpose, the SED36 star tracker was developed, with a design based on the flight qualified SED16/26. In this paper, the SED36 main features will be first presented. Then, the reduction process of the low frequency error will be developed, particularly the optimization of the optical distortion calibration. The result is an attitude low frequency error of 1.1" at 3 sigma along transverse axes. The implementation of these improvements to HYDRA, the new multi-head APS star tracker developed by SODERN, will finally be presented.
Thermal fatigue resistance of NASA WAZ-20 alloy with three commercial coatings
NASA Technical Reports Server (NTRS)
Bizon, P. T.; Oldrieve, R. E.
1975-01-01
Screening tests using three commercial coatings (Jocoat, HI-15, and RT-1A) on the nickel-base alloy NASA WAZ-20 were performed by cyclic exposure in a Mach 1 burner facility. These tests showed Jocoated WAZ-20 to have the best cracking resistance. The thermal fatigue resistance of Jocoated WAZ-20 in both the random polycrystalline and directionally solidified polycrystalline forms relative to that of other superalloys was then evaluated in a fluidized-bed facility. This investigation showed that Jocoated random polycrystalline WAZ-20 ranked approximately in midrange in thermal fatigue life. The thermal fatigue life of directionally solidified Jocoated WAZ-20 was shorter than that of other directionally solidified alloys but still longer than that of all alloys in the random polycrystalline form.
Hypohydration and Acute Thermal Stress Affect Mood State but not Cognition or Dynamic Postural
2012-10-12
of the feet and ankles . The LCD screen presented a cursor interfaced with the movement of the platform. Balance scores were given based on three...Vol- unteers were asked to rate their thermal sensation (TS) using an 8-point Likert scale with verbal anchors from 0 (unbearably cold) to 8...unbearably hot). Thirst was asses- sed using a similar 8-point Likert scale with verbal anchors from 1 (not thirst at all) to 9 (very, very thirsty) (Gagge
Phonon bottleneck identification in disordered nanoporous materials
NASA Astrophysics Data System (ADS)
Romano, Giuseppe; Grossman, Jeffrey C.
2017-09-01
Nanoporous materials are a promising platform for thermoelectrics in that they offer high thermal conductivity tunability while preserving good electrical properties, a crucial requirement for high-efficiency thermal energy conversion. Understanding the impact of the pore arrangement on thermal transport is pivotal to engineering realistic materials, where pore disorder is unavoidable. Although there has been considerable progress in modeling thermal size effects in nanostructures, it has remained a challenge to screen such materials over a large phase space due to the slow simulation time required for accurate results. We use density functional theory in connection with the Boltzmann transport equation to perform calculations of thermal conductivity in disordered porous materials. By leveraging graph theory and regressive analysis, we identify the set of pores representing the phonon bottleneck and obtain a descriptor for thermal transport, based on the sum of the pore-pore distances between such pores. This approach provide a simple tool to estimate phonon suppression in realistic porous materials for thermoelectric applications and enhance our understanding of heat transport in disordered materials.
NASA Astrophysics Data System (ADS)
Mercier, F.; Samaniego, B.; Soriano, T.; Beaufils, G.; Fernandez Lisbona, E.; Dettlaff, K.; Jensen, H.
2014-08-01
The thermal / electrical imbalance phenomenon on the satellite solar arrays is a common issue inherent to the negative thermal voltage coefficient of the triple junction cells, which is usually already taken into account with basic precautions on the solar panel layout.In the frame of the ESA TRP study "Investigation on Solar Array thermal and electrical imbalance phenomenon on power systems equipped with Maximum Power Point Tracker (MPPT)" performed by Airbus Defence & Space (former Astrium Toulouse and Ottobrunn) and TERMA, in-depth analyses were conducted for the first time to better understand and characterize the secondary maximum power point phenomenon for various representative mission cases, whether in Earth vicinity or not. With the help of a newly developed detailed thermo-electrical coupled solver and a wide range of solar cell characterizations in flux and temperature, multiple sets of simulations were run to simulate realistic solar panel characteristics.The study showed that no secondary false maximum power point can be created on the solar panel characteristic IV curve for missions around Earth vicinity, at the sole exception of critical shadowing cases. Furthermore, the same conclusions apply for missions up to Mars orbit. The only potential threats come from the missions further than Mars (typically Jupiter missions) where various very high heterogeneities could lead to multiple maxima. This is deeply linked to the LILT (low illumination low temperature) conditions applied to the current solar cell triple junction characteristics and shape. Moreover, thermo-electrical imbalances that do not create secondary power point can still seriously grieve the solar array power output performances. This power loss can however be accurately assessed by the newly developed solver in support of in-development missions like Juice.
NASA Technical Reports Server (NTRS)
2013-01-01
Topics include: Cloud Absorption Radiometer Autonomous Navigation System - CANS, Software Method for Computed Tomography Cylinder Data Unwrapping, Re-slicing, and Analysis, Discrete Data Qualification System and Method Comprising Noise Series Fault Detection, Simple Laser Communications Terminal for Downlink from Earth Orbit at Rates Exceeding 10 Gb/s, Application Program Interface for the Orion Aerodynamics Database, Hyperspectral Imager-Tracker, Web Application Software for Ground Operations Planning Database (GOPDb) Management, Software Defined Radio with Parallelized Software Architecture, Compact Radar Transceiver with Included Calibration, Software Defined Radio with Parallelized Software Architecture, Phase Change Material Thermal Power Generator, The Thermal Hogan - A Means of Surviving the Lunar Night, Micromachined Active Magnetic Regenerator for Low-Temperature Magnetic Coolers, Nano-Ceramic Coated Plastics, Preparation of a Bimetal Using Mechanical Alloying for Environmental or Industrial Use, Phase Change Material for Temperature Control of Imager or Sounder on GOES Type Satellites in GEO, Dual-Compartment Inflatable Suitlock, Modular Connector Keying Concept, Genesis Ultrapure Water Megasonic Wafer Spin Cleaner, Piezoelectrically Initiated Pyrotechnic Igniter, Folding Elastic Thermal Surface - FETS, Multi-Pass Quadrupole Mass Analyzer, Lunar Sulfur Capture System, Environmental Qualification of a Single-Crystal Silicon Mirror for Spaceflight Use, Planar Superconducting Millimeter-Wave/Terahertz Channelizing Filter, Qualification of UHF Antenna for Extreme Martian Thermal Environments, Ensemble Eclipse: A Process for Prefab Development Environment for the Ensemble Project, ISS Live!, Space Operations Learning Center (SOLC) iPhone/iPad Application, Software to Compare NPP HDF5 Data Files, Planetary Data Systems (PDS) Imaging Node Atlas II, Automatic Calibration of an Airborne Imaging System to an Inertial Navigation Unit, Translating MAPGEN to ASPEN for MER, Support Routines for In Situ Image Processing, and Semi-Supervised Eigenbasis Novelty Detection.
tkLayout: a design tool for innovative silicon tracking detectors
NASA Astrophysics Data System (ADS)
Bianchi, G.
2014-03-01
A new CMS tracker is scheduled to become operational for the LHC Phase 2 upgrade in the early 2020's. tkLayout is a software package developed to create 3d models for the design of the CMS tracker and to evaluate its fundamental performance figures. The new tracker will have to cope with much higher luminosity conditions, resulting in increased track density, harsher radiation exposure and, especially, much higher data acquisition bandwidth, such that equipping the tracker with triggering capabilities is envisaged. The design of an innovative detector involves deciding on an architecture offering the best trade-off among many figures of merit, such as tracking resolution, power dissipation, bandwidth, cost and so on. Quantitatively evaluating these figures of merit as early as possible in the design phase is of capital importance and it is best done with the aid of software models. tkLayout is a flexible modeling tool: new performance estimates and support for different detector geometries can be quickly added, thanks to its modular structure. Besides, the software executes very quickly (about two minutes), so that many possible architectural variations can be rapidly modeled and compared, to help in the choice of a viable detector layout and then to optimize it. A tracker geometry is generated from simple configuration files, defining the module types, layout and materials. Support structures are automatically added and services routed to provide a realistic tracker description. The tracker geometries thus generated can be exported to the standard CMS simulation framework (CMSSW) for full Monte Carlo studies. tkLayout has proven essential in giving guidance to CMS in studying different detector layouts and exploring the feasibility of innovative solutions for tracking detectors, in terms of design, performance and projected costs. This tool has been one of the keys to making important design decisions for over five years now and has also enabled project engineers and simulation experts to focus their efforts on other important or specific issues. Even if tkLayout was designed for the CMS tracker upgrade project, its flexibility makes it experiment-agnostic, so that it could be easily adapted to model other tracking detectors. The technology behind tkLayout is presented, as well as some of the results obtained in the context of the CMS silicon tracker design studies.
A Bit of Fit: Minimalist Intervention in Adolescents Based on a Physical Activity Tracker.
Gaudet, Jeffrey; Gallant, François; Bélanger, Mathieu
2017-07-06
Only 5% of Canadian youth meet the recommended 60 minutes of moderate to vigorous physical activity (MVPA) per day, with leisure time being increasingly allocated to technology usage. Direct-to-consumer mHealth devices that promote physical activity, such as wrist-worn physical activity trackers, have features with potential appeal to youth. The primary purpose of this study was to determine whether a minimalist physical activity tracker-based intervention would lead to an increase in physical activity in young adolescents. A secondary aim of this study was to assess change in physical activity across a 7-week intervention, as measured by the tracker. Using a quasi-experimental crossover design, two groups of 23 young adolescents (aged 13-14 years) were randomly assigned to immediate intervention or delayed intervention. The intervention consisted of wearing a Fitbit-Charge-HR physical activity tracker over a 7-week period. Actical accelerometers were used to measure participants' levels of MVPA before and at the end of intervention periods for each group. Covariates such as age, sex, stage of change for physical activity behavior, and goal commitment were also measured. There was an increase in physical activity over the course of the study period, though it was not related to overall physical activity tracker use. An intervention response did, however, occur in a subset of participants. Specifically, exposure to the physical activity tracker was associated with an average daily increase in MVPA by more than 15 minutes (P=.01) among participants who reported being in the action and maintenance stages of behavior change in relation to participation in physical activity. Participants in the precontemplation, contemplation, and preparation stages of behavior change had no change in their level of MVPA (P=.81). These results suggest that physical activity trackers may elicit improved physical activity related behavior in young adolescents demonstrating a readiness to be active. Future studies should seek to investigate if integrating physical activity trackers as part of more intensive interventions leads to greater increases in physical activity across different levels of stages of behavior change and if these changes can be sustained over longer periods of time. ©Jeffrey Gaudet, François Gallant, Mathieu Bélanger. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 06.07.2017.
Thermal performance and heat transport in aquifer thermal energy storage
NASA Astrophysics Data System (ADS)
Sommer, W. T.; Doornenbal, P. J.; Drijver, B. C.; van Gaans, P. F. M.; Leusbrock, I.; Grotenhuis, J. T. C.; Rijnaarts, H. H. M.
2014-01-01
Aquifer thermal energy storage (ATES) is used for seasonal storage of large quantities of thermal energy. Due to the increasing demand for sustainable energy, the number of ATES systems has increased rapidly, which has raised questions on the effect of ATES systems on their surroundings as well as their thermal performance. Furthermore, the increasing density of systems generates concern regarding thermal interference between the wells of one system and between neighboring systems. An assessment is made of (1) the thermal storage performance, and (2) the heat transport around the wells of an existing ATES system in the Netherlands. Reconstruction of flow rates and injection and extraction temperatures from hourly logs of operational data from 2005 to 2012 show that the average thermal recovery is 82 % for cold storage and 68 % for heat storage. Subsurface heat transport is monitored using distributed temperature sensing. Although the measurements reveal unequal distribution of flow rate over different parts of the well screen and preferential flow due to aquifer heterogeneity, sufficient well spacing has avoided thermal interference. However, oversizing of well spacing may limit the number of systems that can be realized in an area and lower the potential of ATES.
... certain health conditions External Resources Weight loss, weight management, nutrition, meal planning tools… Super Tracker SuperTracker: My Plan Food Diary [PDF – 34KB] Physical Activity Diary [PDF – 52KB] ...
Centroid tracker and aimpoint selection
NASA Astrophysics Data System (ADS)
Venkateswarlu, Ronda; Sujata, K. V.; Venkateswara Rao, B.
1992-11-01
Autonomous fire and forget weapons have gained importance to achieve accurate first pass kill by hitting the target at an appropriate aim point. Centroid of the image presented by a target in the field of view (FOV) of a sensor is generally accepted as the aimpoint for these weapons. Centroid trackers are applicable only when the target image is of significant size in the FOV of the sensor but does not overflow the FOV. But as the range between the sensor and the target decreases the image of the target will grow and finally overflow the FOV at close ranges and the centroid point on the target will keep on changing which is not desirable. And also centroid need not be the most desired/vulnerable point on the target. For hardened targets like tanks, proper aimpoint selection and guidance up to almost zero range is essential to achieve maximum kill probability. This paper presents a centroid tracker realization. As centroid offers a stable tracking point, it can be used as a reference to select the proper aimpoint. The centroid and the desired aimpoint are simultaneously tracked to avoid jamming by flares and also to take care of the problems arising due to image overflow. Thresholding of gray level image to binary image is a crucial step in centroid tracker. Different thresholding algorithms are discussed and a suitable algorithm is chosen. The real-time hardware implementation of centroid tracker with a suitable thresholding technique is presented including the interfacing to a multimode tracker for autonomous target tracking and aimpoint selection. The hardware uses very high speed arithmetic and programmable logic devices to meet the speed requirement and a microprocessor based subsystem for the system control. The tracker has been evaluated in a field environment.
Use of LysoTracker dyes: a flow cytometric study of autophagy.
Chikte, Shaheen; Panchal, Neelam; Warnes, Gary
2014-02-01
The flow cytometric use of LysoTracker dyes was employed to investigate the autophagic process and to compare this with the upregulation of autophagy marker, the microtubule-associated protein LC3B. Although the mechanism of action of LysoTracker dyes is not fully understood, they have been used in microscopy to image acidic spherical organelles, and their use in flow cytometry has not been thoroughly investigated in the study of autophagy. This investigation uses numerous autophagy-inducing agents including chloroquine (CQ), rapamycin, low serum (<1%) RPMI, and nutrient starvation to induce autophagy in Jurkat T-cell leukemia and K562 erythromyeloid cell lines. LC3B showed an increase with CQ treatment although this was different to LysoTracker signals in terms of dose and time. Rapamycin, low serum (<1%) RPMI, and nutrient starvation induction of autophagy also induced an increase in LysoTracker and LC3B signals. CQ also induced apoptosis in cell lines, which was blocked by pan-caspase inhibitor z-VAD resulting in a reduction in cells undergoing apoptosis and a subsequent upregulation of autophagic markers LC3B and lysosomal dye signals. Given that LC3B and LysoTracker are measuring different biological events in the autophagic process, they surprisingly both upregulated during autophagic process. This study, however, shows that although LysoTracker dyes do not specifically label lysosomes or autophagosomes within the cell, they allow the simultaneous measurement of an autophagy-related process and other live-cell functions, which are not possible with the standard LC3B antibody-labeling technique. This method has the advantage of other live-cell LCB-GFP-tagged experiments in that be used to analyze patient cells as well as easier to use and significantly less costly. Copyright © 2013 International Society for Advancement of Cytometry.
NASA Astrophysics Data System (ADS)
Aguilar-Marín, Pablo; Chavez-Bacilio, Mario; Jáuregui-Rosas, Segundo
2018-05-01
Tracker is a piece of freeware software, designed to use video recorded images of the motion of objects as input data, and has been mostly applied in physics education to analyse and simulate physical phenomena in mechanics. In this work we report the application of Tracker to the study of experiments in electricity and magnetism using analog instruments for electrical signal measurements. As we are unable to directly video-track the motion of electrons in electric circuits, the angular deflections of the instruments’ pointers were video captured instead. The kinematic variables (angular position as a function of time) had to be related to the electrical ones (voltages and currents as a function of time). Two well-known experiments in physics teaching, the RC circuit for charging and discharging a capacitor and Faraday electromagnetic induction, were chosen to illustrate the procedures. The third experiment analysed and modeled with Tracker was the rather well-known electromagnetic retardation of disk- or cylinder-shaped magnets falling inside non-magnetic metallic pipes. Instead of metallic pipes we used an aluminum plate with an arrangement of a couple of parallelepiped-shaped magnets falling parallel to the plate. In the three cases studied, the experimental and the Tracker simulation results were in very good agreement. These outcomes show that it is possible to exploit the potential of Tracker software in areas other than mechanics, in areas where electrical signals are involved. The experiments are inexpensive and simple to perform, and are suitable for high school and introductory undergraduate courses in electricity, magnetism and electronics. We propose the use of Tracker combined with analog measuring devices to explore further its applications in electricity, magnetism, electronics and in other experimental sciences where electrical signals are involved.
Santiani, Alexei; Ugarelli, Alejandra; Evangelista-Vargas, Shirley
2016-10-01
Epididymal alpaca sperm represent an alternative model for the study of alpaca semen. The objective of this study was to characterize the normal values of some functional variables in epididymal alpaca sperm using imaging flow cytometry. Alpaca testicles (n=150) were processed and sperm were recovered from the cauda epididymides. Only 76 samples with acceptable motility and sperm count were considered for assessment by imaging flow cytometry. Acrosome integrity and integrity/viability were assessed by FITC-PSA/PI and FITC-PNA/PI. Mitochondrial membrane potential (MMP) was assessed by MitoTracker CMXRos and MitoTracker Deep Red FM. Lipid peroxidation was evaluated using BODIPY 581/591 C11. Results show that the mean values for acrosome-intact sperm were 95.03±6.39% and 93.34±7.96%, using FITC-PSA and FITC-PNA, respectively. The mean values for acrosome-intact viable sperm were 60.58±12.12% with FITC-PSA/PI and 58.81±12.94% with FITC-PNA/PI. Greater MMP was detected in 65.03±15.92% and 59.52±19.19%, using MitoTracker CMXRos and MitoTracker Deep Red FM, respectively. Lipid peroxidation was 0.84±0.95%. Evaluation of acrosome-intact and acrosome-intact viable sperm with FITC-PSA/PI compared with. FITC-PNA/PI or MMP with MitoTracker CMXRos compared with MitoTracker Deep Red FM were correlated (P<0.05). The MMP using MitoTracker CMXRos was the only variable correlated (P<0.05) with sperm motility (r=0.3979). This report provides a basis for future research related to alpaca semen using the epididymal sperm model. Copyright © 2016 Elsevier B.V. All rights reserved.
Bosc, R; Fitoussi, A; Pigneur, F; Tacher, V; Hersant, B; Meningaud, J-P
2017-08-01
The augmented reality on smart glasses allows the surgeon to visualize three-dimensional virtual objects during surgery, superimposed in real time to the anatomy of the patient. This makes it possible to preserve the vision of the surgical field and to dispose of added computerized information without the need to use a physical surgical guide or a deported screen. The three-dimensional objects that we used and visualized in augmented reality came from the reconstructions made from the CT-scans of the patients. These objects have been transferred through a dedicated application on stereoscopic smart glasses. The positioning and the stabilization of the virtual layers on the anatomy of the patients were obtained thanks to the recognition, by the glasses, of a tracker placed on the skin. We used this technology, in addition to the usual locating methods for preoperative planning and the selection of perforating vessels for 12 patients operated on a breast reconstruction, by perforating flap of deep lower epigastric artery. The "hands-free" smart glasses with two stereoscopic screens make it possible to provide the reconstructive surgeon with binocular visualization in the operative field of the vessels identified with the CT-scan. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Rett syndrome: basic features of visual processing-a pilot study of eye-tracking.
Djukic, Aleksandra; Valicenti McDermott, Maria; Mavrommatis, Kathleen; Martins, Cristina L
2012-07-01
Consistently observed "strong eye gaze" has not been validated as a means of communication in girls with Rett syndrome, ubiquitously affected by apraxia, unable to reply either verbally or manually to questions during formal psychologic assessment. We examined nonverbal cognitive abilities and basic features of visual processing (visual discrimination attention/memory) by analyzing patterns of visual fixation in 44 girls with Rett syndrome, compared with typical control subjects. To determine features of visual fixation patterns, multiple pictures (with the location of the salient and presence/absence of novel stimuli as variables) were presented on the screen of a TS120 eye-tracker. Of the 44, 35 (80%) calibrated and exhibited meaningful patterns of visual fixation. They looked longer at salient stimuli (cartoon, 2.8 ± 2 seconds S.D., vs shape, 0.9 ± 1.2 seconds S.D.; P = 0.02), regardless of their position on the screen. They recognized novel stimuli, decreasing the fixation time on the central image when another image appeared on the periphery of the slide (2.7 ± 1 seconds S.D. vs 1.8 ± 1 seconds S.D., P = 0.002). Eye-tracking provides a feasible method for cognitive assessment and new insights into the "hidden" abilities of individuals with Rett syndrome. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Cameron, R.; Aldcroft, T.; Podgorski, W. A.; Freeman, M. D.
2000-01-01
The aspect determination system of the Chandra X-ray Observatory plays a key role in realizing the full potential of Chandra's X-ray optics and detectors. We review the performance of the spacecraft hardware components and sub-systems, which provide information for both real time control of the attitude and attitude stability of the Chandra Observatory and also for more accurate post-facto attitude reconstruction. These flight components are comprised of the aspect camera (star tracker) and inertial reference units (gyros), plus the fiducial lights and fiducial transfer optics which provide an alignment null reference system for the science instruments and X-ray optics, together with associated thermal and structural components. Key performance measures will be presented for aspect camera focal plane data, gyro performance both during stable pointing and during maneuvers, alignment stability and mechanism repeatability.
Minimum Error Bounded Efficient L1 Tracker with Occlusion Detection (PREPRINT)
2011-01-01
Minimum Error Bounded Efficient `1 Tracker with Occlusion Detection Xue Mei\\ ∗ Haibin Ling† Yi Wu†[ Erik Blasch‡ Li Bai] \\Assembly Test Technology...proposed BPR-L1 tracker is tested on several challenging benchmark sequences involving chal- lenges such as occlusion and illumination changes. In all...point method de - pends on the value of the regularization parameter λ. In the experiments, we found that the total number of PCG is a few hundred. The
Long-life 3-axis satellite attitude sensing, phase 1
NASA Technical Reports Server (NTRS)
Arild, Tor
1987-01-01
The purpose was to investigate the feasibility of new, moderate-cost, high reliability navigation sensors for high-altitude satellites, using stellar sources to obviate the use of gyroscopic devices. The primary investigation focused on the need for developing a star tracker model to replace an old star tracker which is still needed for current probe and satellite programs. One innovative element of the proposed star tracker was the design, development, and testing of technology components related to a phase scrambler plate. The purpose of the phase scrambler plate is to convert the impulse response of the optical system from a point image to a uniformly bright, square, angularly large, in-focus image of the star source. A collimated star source was built and tested. A breadboard star tracker with an 8 x 8 degree field of view was designed and built. It was tested in normal quad-cell mode (without the phase scrambler plate) and with the phase scrambler plate. Although the phase scrambler plate was crudely made, the performance of the star tracker breadboard was greatly improved using the phase scrambler plate, instead of system defocus. If further developed, the phase scrambler plate may be added as a low-cost retroconversion to any objective lens to greatly improve quad-cell or CCD array tracking; applications include star trackers, laser metrology, laser machining optics, and surveying instrumentation.
Development of a digital mobile solar tracker
NASA Astrophysics Data System (ADS)
Baidar, S.; Kille, N.; Ortega, I.; Sinreich, R.; Thomson, D.; Hannigan, J.; Volkamer, R.
2015-11-01
We have constructed and deployed a fast digital solar tracker aboard a moving ground-based platform. The tracker consists of two rotating mirrors, a lens, an imaging camera, and a motion compensation system that provides the Euler angles of the mobile platform in real time. The tracker can be simultaneously coupled to UV-Vis and FTIR spectrometers making it a versatile tool to measure the absorption of trace gases using solar incoming radiation. The integrated system allows the tracker to operate autonomously while the mobile laboratory is in motion. Mobile direct sun Differential Optical Absorption Spectroscopy (mobile DS-DOAS) observations using this tracker were conducted during summer 2014 as part of the Front Range Photochemistry and Pollution Experiment (FRAPPE) in Colorado, USA. We demonstrate an angular precision of 0.052° (about 1/10 of the solar disk diameter) during research drives, and verify this tracking precision from measurements of the center to limb darkening (CLD, the changing appearance of Fraunhofer lines) in the mobile DS-DOAS spectra. The high photon flux from direct sun observation enables measurements of nitrogen dioxide (NO2) slant columns with high temporal resolution, and reveals spatial detail in the variations of NO2 vertical column densities (VCDs). The NO2 VCD from DS-DOAS is compared with a co-located MAX-DOAS instrument. Overall good agreement is observed amid a highly heterogeneous air mass.
Development of a digital mobile solar tracker
NASA Astrophysics Data System (ADS)
Baidar, Sunil; Kille, Natalie; Ortega, Ivan; Sinreich, Roman; Thomson, David; Hannigan, James; Volkamer, Rainer
2016-03-01
We have constructed and deployed a fast digital solar tracker aboard a moving ground-based platform. The tracker consists of two rotating mirrors, a lens, an imaging camera, and a motion compensation system that provides the Euler angles of the mobile platform in real time. The tracker can be simultaneously coupled to UV-Vis and Fourier transform infrared spectrometers, making it a versatile tool to measure the absorption of trace gases using solar incoming radiation. The integrated system allows the tracker to operate autonomously while the mobile laboratory is in motion. Mobile direct sun differential optical absorption spectroscopy (mobile DS-DOAS) observations using this tracker were conducted during summer 2014 as part of the Front Range Air Pollution and Photochemistry Experiment (FRAPPE) in Colorado, USA. We demonstrate an angular precision of 0.052° (about 1/10 of the solar disk diameter) during research drives and verify this tracking precision from measurements of the center to limb darkening (CLD, the changing appearance of Fraunhofer lines) in the mobile DS-DOAS spectra. The high photon flux from direct sun observation enables measurements of nitrogen dioxide (NO2) slant columns with high temporal resolution and reveals spatial detail in the variations of NO2 vertical column densities (VCDs). The NO2 VCD from DS-DOAS is compared with a co-located MAX-DOAS instrument. Overall good agreement is observed amid a highly heterogeneous air mass.
Bush, Nigel E; Ouellette, Gary; Kinn, Julie
2014-12-01
Many military personnel returning from deployment experience increases in psychological symptoms, including post-traumatic stress disorder (PTSD), depression, and mood changes. Patient health diaries are commonly used for self-reporting over time away from the clinic. "T2 Mood Tracker" is an application ("app") for smartphones and other mobile devices that enables users to rate their moods, to self-monitor across time, and to report their emotional experiences to health providers. We designed T2 Mood Tracker to track symptoms associated with deployment-related behavioral health issues, including PTSD, Head Injury, Stress, Depression, Anxiety, and General Well-Being. We field-tested T2 Mood Tracker with a small sample of redeployed soldiers under treatment for behavioral health issues at a Warrior Transition Unit. Participants used the app an average of 10 different days over the 2- to 3-week test period. Consensus was that T2 Mood Tracker was easy to use, useful and beneficial. The majority said they would use the app in the future, would recommend it to other service members, and would use the app to share their mood information with a provider. Warrior Transition Unit providers were enthusiastic about the potential of T2 Mood Tracker as a tool for use with their patients. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
NASA Astrophysics Data System (ADS)
Acero, R.; Santolaria, J.; Pueo, M.; Aguilar, J. J.; Brau, A.
2015-11-01
High-range measuring equipment like laser trackers need large dimension calibrated reference artifacts in their calibration and verification procedures. In this paper, a new verification procedure for portable coordinate measuring instruments based on the generation and evaluation of virtual distances with an indexed metrology platform is developed. This methodology enables the definition of an unlimited number of reference distances without materializing them in a physical gauge to be used as a reference. The generation of the virtual points and reference lengths derived is linked to the concept of the indexed metrology platform and the knowledge of the relative position and orientation of its upper and lower platforms with high accuracy. It is the measuring instrument together with the indexed metrology platform one that remains still, rotating the virtual mesh around them. As a first step, the virtual distances technique is applied to a laser tracker in this work. The experimental verification procedure of the laser tracker with virtual distances is simulated and further compared with the conventional verification procedure of the laser tracker with the indexed metrology platform. The results obtained in terms of volumetric performance of the laser tracker proved the suitability of the virtual distances methodology in calibration and verification procedures for portable coordinate measuring instruments, broadening and expanding the possibilities for the definition of reference distances in these procedures.
Vann, Charles S.
2003-09-09
This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.
A novel design of dual-channel optical system of star-tracker based on non-blind area PAL system
NASA Astrophysics Data System (ADS)
Luo, Yujie; Bai, Jian
2016-07-01
Star-tracker plays an important role in satellite navigation. Considering the satellites on near-Earth orbit, the system usually has two optical systems: one for observing the profile of Earth and the other for capturing the positions of stars. In this paper, we demonstrate a novel kind of dual-channel optical observation system of star-tracker with non-blind area PAL imaging system based on dichroic filter, which can combine both different observation channels into an integrated structure and realize the feature of miniaturization. According to the practical usage of star-tracker and the features of dichroic filter, we set the ultraviolet band as the PAL channel to observe the Earth with the FOV ranging from 40°-60°, and set the visible band as the front imaging channel to capture the stars far away from this system with the FOV ranging from 0°-20°. Consequently, the rays of both channels are converged on the same image plane, improving the efficiency of pixels of detector and reducing the weight and size of whole star-tracker system.
Ground Testing Strategies for Verifying the Slew Rate Tolerance of Star Trackers
Dzamba, Tom; Enright, John
2014-01-01
The performance of a star tracker is largely based on the availability of its attitude solution. Several methods exist to assess star tracker availability under both static and dynamic imaging conditions. However, these methods typically make various idealizations that can limit the accuracy of these results. This study aims to increase the fidelity of star tracker availability modeling by accounting for the effects of detection logic and pixel saturation on star detection. We achieve this by developing an analytical model for the focal plane intensity distribution of a star in the presence of sensor slew. Using the developed model, we examine the effects of slew rate on star detection using simulations and lab tests. The developed approach allows us to determine the maximum slew rate for which a star of a given stellar magnitude can still be detected. This information can then be used to describe the availability of a star tracker attitude solution as a function of slew rate, both spatially, across the entire celestial sphere, or locally, along a specified orientation track. PMID:24577522
Effective Visual Tracking Using Multi-Block and Scale Space Based on Kernelized Correlation Filters
Jeong, Soowoong; Kim, Guisik; Lee, Sangkeun
2017-01-01
Accurate scale estimation and occlusion handling is a challenging problem in visual tracking. Recently, correlation filter-based trackers have shown impressive results in terms of accuracy, robustness, and speed. However, the model is not robust to scale variation and occlusion. In this paper, we address the problems associated with scale variation and occlusion by employing a scale space filter and multi-block scheme based on a kernelized correlation filter (KCF) tracker. Furthermore, we develop a more robust algorithm using an appearance update model that approximates the change of state of occlusion and deformation. In particular, an adaptive update scheme is presented to make each process robust. The experimental results demonstrate that the proposed method outperformed 29 state-of-the-art trackers on 100 challenging sequences. Specifically, the results obtained with the proposed scheme were improved by 8% and 18% compared to those of the KCF tracker for 49 occlusion and 64 scale variation sequences, respectively. Therefore, the proposed tracker can be a robust and useful tool for object tracking when occlusion and scale variation are involved. PMID:28241475
Effective Visual Tracking Using Multi-Block and Scale Space Based on Kernelized Correlation Filters.
Jeong, Soowoong; Kim, Guisik; Lee, Sangkeun
2017-02-23
Accurate scale estimation and occlusion handling is a challenging problem in visual tracking. Recently, correlation filter-based trackers have shown impressive results in terms of accuracy, robustness, and speed. However, the model is not robust to scale variation and occlusion. In this paper, we address the problems associated with scale variation and occlusion by employing a scale space filter and multi-block scheme based on a kernelized correlation filter (KCF) tracker. Furthermore, we develop a more robust algorithm using an appearance update model that approximates the change of state of occlusion and deformation. In particular, an adaptive update scheme is presented to make each process robust. The experimental results demonstrate that the proposed method outperformed 29 state-of-the-art trackers on 100 challenging sequences. Specifically, the results obtained with the proposed scheme were improved by 8% and 18% compared to those of the KCF tracker for 49 occlusion and 64 scale variation sequences, respectively. Therefore, the proposed tracker can be a robust and useful tool for object tracking when occlusion and scale variation are involved.
Development and Testing of the AMEGO Silicon Tracker System
NASA Astrophysics Data System (ADS)
Griffin, Sean; Amego Team
2018-01-01
The All-sky Medium Energy Gamma-ray Observatory (AMEGO) is a probe-class mission in consideration for the 2020 decadal review designed to operate at energies from ˜ 200 keV to > 10 GeV. Operating a detector in this energy regime is challenging due to the crossover in the interaction cross-section for Compton scattering and pair production. AMEGO is made of four major subsystems: a plastic anticoincidence detector for rejecting cosmic-ray events, a silicon tracker for measuring the energies of Compton scattered electrons and pair-production products, a CZT calorimeter for measuring the energy and location of Compton scattered photons, and a CsI calorimeter for measuring the energy of the pair-production products at high energies. The tracker comprises layers of dual-sided silicon strip detectors which provide energy and localization information for Compton scattering and pair-production events. A prototype tracker system is under development at GSFC; in this contribution we provide details on the verification, packaging, and testing of the prototype tracker, as well as present plans for the development of the front-end electronics, beam tests, and a balloon flight.
Long Term Outdoor Testing of Low Concentration Solar Modules
NASA Astrophysics Data System (ADS)
Fraas, Lewis; Avery, James; Minkin, Leonid; Huang, H. X.; Hebrink, Tim; Hurt, Rik; Boehm, Robert
2011-12-01
A 1-axis carousel tracker equipped with four 3-sun low-concentration mirror modules has now been under test outdoors at the University of Nevada in Las Vegas (UNLV) for three years. There are three unique features associated with this unit. First, simple linear mirrors are used to reduce the amount of expensive single crystal silicon in order to potentially lower the module cost while potentially maintaining cell efficiencies over 20% and high module efficiency. Simple linear mirrors also allow the use of a single axis tracker. Second, the azimuth carousel tracker is also unique allowing trackers to be used on commercial building rooftops. Third, an experiment is underway comparing aluminum based mirrors with novel 3M Company multilayer polymeric mirrors which are potentially very low cost. Comparing the data from March of 2008 through March of 2011 shows that the aluminum mirror degradation to date is negligible and that the carousel tracker has been operating continuously and reliable. Also, no degradation has been observed for the 3M brand cool mirrors after one year in use.
Robust visual tracking via multiscale deep sparse networks
NASA Astrophysics Data System (ADS)
Wang, Xin; Hou, Zhiqiang; Yu, Wangsheng; Xue, Yang; Jin, Zefenfen; Dai, Bo
2017-04-01
In visual tracking, deep learning with offline pretraining can extract more intrinsic and robust features. It has significant success solving the tracking drift in a complicated environment. However, offline pretraining requires numerous auxiliary training datasets and is considerably time-consuming for tracking tasks. To solve these problems, a multiscale sparse networks-based tracker (MSNT) under the particle filter framework is proposed. Based on the stacked sparse autoencoders and rectifier linear unit, the tracker has a flexible and adjustable architecture without the offline pretraining process and exploits the robust and powerful features effectively only through online training of limited labeled data. Meanwhile, the tracker builds four deep sparse networks of different scales, according to the target's profile type. During tracking, the tracker selects the matched tracking network adaptively in accordance with the initial target's profile type. It preserves the inherent structural information more efficiently than the single-scale networks. Additionally, a corresponding update strategy is proposed to improve the robustness of the tracker. Extensive experimental results on a large scale benchmark dataset show that the proposed method performs favorably against state-of-the-art methods in challenging environments.
He, Dong; Luo, Wen; Wang, Zhiyuan; Lv, Pengmei; Yuan, Zhenhong; Huang, Shaowei; Xv, Jingliang
2017-07-01
Directed evolution has been proved an effective way to improve the stability of proteins, but high throughput screening assays for directed evolution with simultaneous improvement of two or more properties are still rare. In this study, we aimed to establish a membrane-blot assay for use in the high-throughput screening of Rhizomucor miehei lipases (RMLs). With the assistance of the membrane-blot screening assay, a mutant E47K named G10 that showed improved thermal stability was detected in the first round of error-prone PCR. Using G10 as the parent, two variants G10-11 and G10-20 that showed improved thermal stability and methanol tolerance without loss of activity compared to the wild type RML were obtained. The T 50 60 -value of G10-11 and G10-20 increased by 12°C and 6.5°C, respectively. After incubation for 1h, the remaining residual activity of G10-11 and G10-20 was 63.45% and 74.33%, respectively, in 50% methanol, and 15.98% and 30.22%, respectively, in 80% methanol. Thus, we successfully developed a membrane-blot assay that could be used for the high-throughput screening of RMLs with improved thermostability and methanol tolerance. Based on our findings, we believe that our newly developed membrane-blot assay will have potential applications in directed evolution in the future. Copyright © 2017 Elsevier Inc. All rights reserved.
... 3 years 4 years 5 years Milestone Tracker App Milestones in Action: Photos & Videos 2 months 4 ... milestone checklists (PDF) Download the Milestone Tracker mobile app View the Milestones in Action photo and video ...
75 FR 5996 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-05
... and OMB Number: Synchronized Predeployment and Operational Tracker (SPOT) System; OMB Control Number... Operational Tracker (SPOT) System before deployment outside the United States. Data collection on contractors...
NASA Technical Reports Server (NTRS)
Otaguro, W. S.; Kesler, L. O.; Land, K. C.; Rhoades, D. E.
1987-01-01
An intelligent tracker capable of robotic applications requiring guidance and control of platforms, robotic arms, and end effectors has been developed. This packaged system capable of supervised autonomous robotic functions is partitioned into a multiple processor/parallel processing configuration. The system currently interfaces to cameras but has the capability to also use three-dimensional inputs from scanning laser rangers. The inputs are fed into an image processing and tracking section where the camera inputs are conditioned for the multiple tracker algorithms. An executive section monitors the image processing and tracker outputs and performs all the control and decision processes. The present architecture of the system is presented with discussion of its evolutionary growth for space applications. An autonomous rendezvous demonstration of this system was performed last year. More realistic demonstrations in planning are discussed.
Context Aware Programmable Trackers for the Next Generation Internet
NASA Astrophysics Data System (ADS)
Sousa, Pedro
This work introduces and proposes the concept of context aware programmable trackers for the next generation Internet. The proposed solution gives ground for the development of advanced applications based on the P2P paradigm and will foster collaborative efforts among several network entities (e.g. P2P applications and ISPs). The proposed concept of context aware programmable trackers allows that several peer selection strategies might be supported by a P2P tracker entity able to improve the peer selection decisions according with pre-defined objectives and external inputs provided by specific services. The flexible, adaptive and enhanced peer selection semantics that might be achieved by the proposed solution will contribute for devising novel P2P based services and business models for the future Internet.
Multiple Image Arrangement for Subjective Quality Assessment
NASA Astrophysics Data System (ADS)
Wang, Yan; Zhai, Guangtao
2017-12-01
Subjective quality assessment serves as the foundation for almost all visual quality related researches. Size of the image quality databases has expanded from dozens to thousands in the last decades. Since each subjective rating therein has to be averaged over quite a few participants, the ever-increasing overall size of those databases calls for an evolution of existing subjective test methods. Traditional single/double stimulus based approaches are being replaced by multiple image tests, where several distorted versions of the original one are displayed and rated at once. And this naturally brings upon the question of how to arrange those multiple images on screen during the test. In this paper, we answer this question by performing subjective viewing test with eye tracker for different types arrangements. Our research indicates that isometric arrangement imposes less duress on participants and has more uniform distribution of eye fixations and movements and therefore is expected to generate more reliable subjective ratings.
The forensic holodeck: an immersive display for forensic crime scene reconstructions.
Ebert, Lars C; Nguyen, Tuan T; Breitbeck, Robert; Braun, Marcel; Thali, Michael J; Ross, Steffen
2014-12-01
In forensic investigations, crime scene reconstructions are created based on a variety of three-dimensional image modalities. Although the data gathered are three-dimensional, their presentation on computer screens and paper is two-dimensional, which incurs a loss of information. By applying immersive virtual reality (VR) techniques, we propose a system that allows a crime scene to be viewed as if the investigator were present at the scene. We used a low-cost VR headset originally developed for computer gaming in our system. The headset offers a large viewing volume and tracks the user's head orientation in real-time, and an optical tracker is used for positional information. In addition, we created a crime scene reconstruction to demonstrate the system. In this article, we present a low-cost system that allows immersive, three-dimensional and interactive visualization of forensic incident scene reconstructions.
Co-located haptic and 3D graphic interface for medical simulations.
Berkelman, Peter; Miyasaka, Muneaki; Bozlee, Sebastian
2013-01-01
We describe a system which provides high-fidelity haptic feedback in the same physical location as a 3D graphical display, in order to enable realistic physical interaction with virtual anatomical tissue during modelled procedures such as needle driving, palpation, and other interventions performed using handheld instruments. The haptic feedback is produced by the interaction between an array of coils located behind a thin flat LCD screen, and permanent magnets embedded in the instrument held by the user. The coil and magnet configuration permits arbitrary forces and torques to be generated on the instrument in real time according to the dynamics of the simulated tissue by activating the coils in combination. A rigid-body motion tracker provides position and orientation feedback of the handheld instrument to the computer simulation, and the 3D display is produced using LCD shutter glasses and a head-tracking system for the user.
Characterization of Phase Separation Propensity for Amorphous Spray Dried Dispersions.
McNamara, Daniel; Yin, Shawn; Pan, Duohai; Crull, George; Timmins, Peter; Vig, Balvinder
2017-02-06
A generalized screening approach, applying isothermal calorimetry at 37 °C 100% RH, to formulations of spray dried dispersions (SDDs) for two active pharmaceutical ingredients (APIs) (BMS-903452 and BMS-986034) is demonstrated. APIs 452 and 034, with similar chemotypes, were synthesized and promoted during development for oral dosing. Both APIs were formulated as SDDs for animal exposure studies using the polymer hydroxypropylmethlycellulose acetyl succinate M grade (HPMCAS-M). 452 formulated at 30% (wt/wt %) was an extremely robust SDD that was able to withstand 40 °C 75% RH open storage conditions for 6 months with no physical evidence of crystallization or loss of dissolution performance. Though 034 was a chemical analogue with similar physical chemical properties to 452, a physically stable SDD of 034 could not be formulated in HPMCAS-M at any of the drug loads attempted. This study was used to develop experience with specific physical characterization laboratory techniques to evaluate the physical stability of SDDs and to characterize the propensity of SDDs to phase separate and possibly crystallize. The screening strategy adopted was to stress the formulated SDDs with a temperature humidity screen, within the calorimeter, and to apply orthogonal analytical techniques to gain a more informed understanding of why these SDDs formulated with HPMCAS-M demonstrated such different physical stability. Isothermal calorimetry (thermal activity monitor, TAM) was employed as a primary stress screen wherein the SDD formulations were monitored for 3 days at 37 °C 100% RH for signs of phase separation and possible crystallization of API. Powder X-ray diffraction (pXRD), modulated differential scanning calorimetry (mDSC), Fourier transform infrared spectroscopy (FTIR), and solid state nuclear magnetic resonance (ssNMR) were all used to examine formulated SDDs and neat amorphous drug. 452 SDDs formulated at 30% (wt/wt %) or less did not show phase separation behavior upon exposure to 37 °C 100% RH for 3 days. 034 SDD formulations from 10 through 50% (wt/wt %) all demonstrated thermal traces consistent with exothermic phase separation events over 3 days at 37 °C 100% RH in the TAM. However, only the 15, 30, and 50% containing 034 samples showed pXRD patterns consistent with crystalline material in post-TAM samples. Isothermal calorimetry is a useful screening tool to probe robust SDD physical performance and help investigate the level of drug polymer miscibility under a humid stress. Orthogonal analytical techniques such as pXRD, ssNMR, and FTIR were key in this SDD formulation screening to gain physical understanding and confirm or refute whether physical changes occur during the observed thermal events characterized by the calorimetric screening experiments.
NASA Astrophysics Data System (ADS)
Li Heng, Su; Chow, Winston
2017-04-01
Human thermal comfort research is important as climate discomfort can adversely affect both health and work productivity in cities; however, such biometeorological work in low-latitude urban areas is still relatively unstudied hitherto. In the tropical metropolis of Singapore, a suite of policies have been implemented aimed at improving environmental sustainability via increasing car-free commutes and pedestrian movement during work/school journeys, with the consequence that individuals will likely have increased personal exposure through a variety of spaces (and climates) during typical daily activities. As such, research into exploring the thermal (dis)comfort experienced during pedestrian movements across these indoor, outdoor and transitional (semi-outdoor) spaces would yield interesting applied biometerological insights. This pilot study thus investigates how pedestrian thermal comfort varies spatially across a university campus, and how the physical intensity of pedestrian travel affects thermal comfort across these spaces. Over a 10-week period, we profiled six students for both their objective and subjective pedestrian thermal comfort during traverses across different spaces. Data were obtained through use of (a.) of a heat stress sensor, (b.) a fitness tracker, and (b.) a questionnaire survey to record traverse measurements of the microclimate, their physiological data, and their perceived microclimate comfort respectively. Measured climate and physiological data were used to derive commonly-used thermal comfort indices like wet-bulb globe temperature (WBGT) and physiological equivalent temperature (PET). Further, interviews were conducted with all six subjects at the end of the fieldwork period to ascertain details on individual acclimatization behavior and adaptation strategies. The results indicate that (a.) more than 50% of the microclimatic conditions within each indoor, semi-outdoor, and outdoor space exceeded heat stress thresholds of both PET and WBGT, and that participants often were at "high" risk of heat stress from pedestrian movement; (b.) participants were most comfortable with humidity sensations across all spaces compared to other microclimate sensations (e.g. wind, heat, sun); (c.) correlation between microclimate sensation and WBGT varied across participants and across spaces, with stronger correlation between sun sensation votes and WBGT for most participants, and (d.) heart rates of individuals were not significant in estimating and predicting PET for activities such as pedestrian walking. Present results confirm that WBGT applies better to hot climates and outdoor thermal comfort, but not so for hot, humid climates and indoor thermal comfort. Self-reported (subjective) thermal comfort also differed from measured (objective) thermal comfort and across participants because acclimatized individuals can have different sensitivities and acceptance towards (dis)comfort arising from pedestrian movement across spaces. Finally, we suggest that future pedestrian thermal comfort studies employ longitudinal studies and traverse measurements to consider the critical aspects of thermal history and individual sensitivities to on (dis)comfort levels.
NASA Astrophysics Data System (ADS)
Belen'kii, Mikhail S.; Rye, Vincent; Runyeon, Hope
2007-09-01
A concept of a Hybrid Wavefront-based Stochastic Parallel Gradient Decent (WSPGD) Adaptive Optics (AO) system for correcting the combined effects of Beacon Anisoplanatism and Thermal Blooming is introduced. This system integrates a conventional phase conjugate (PC) AO system with a WSPGD AO system. It uses on-axis wavefront measurements of a laser return from an extended beacon to generate initial deformable mirror (DM) commands. Since high frequency phase components are removed from the wavefront of a laser return by a low-pass filter effect of an extended beacon, the system also uses off-axis wavefront measurements to provide feedback for a multi-dithering beam control algorithm in order to generate additional DM commands that account for those missing high frequency phase components. Performance of the Hybrid WSPGD AO system was evaluated in simulation using a wave optics code. Numerical analysis was performed for two tactical scenarios that included ranges of L = 2 km and L = 20 km, ratio of aperture diameter to Fried parameter, D/r 0, of up to 15, ratio of beam spot size at the target to isoplanatic angle, θ B/θ 0, of up to 40, and general distortion number characterizing the strength of Thermal Blooming, N d = 50, 75, and 100. A line-of-sight in the corrected beam was stabilized using a target-plane tracker. The simulation results reveal that the Hybrid WSPGD AO system can efficiently correct the effects of Beacon Anisoplanatism and Thermal Blooming, providing improved compensation of Thermal Blooming in the presence of strong turbulence. Simulation results also indicate that the Hybrid WSPGD AO system outperforms a conventional PC AO system, increasing the Strehl ratio by up to 300% in less than 50 iterations. A follow-on laboratory demonstration performed under a separate program confirmed our theoretical predictions.
78 FR 38695 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-27
..., Associated Form and OMB Number: Synchronized Predeployment and Operational Tracker (SPOT) System; OMB Control... Operational Tracker (SPOT) System before deployment outside of the United States. Data collection on...
Optical contacting for gravity probe star tracker
NASA Technical Reports Server (NTRS)
Wright, J. J.; Zissa, D. E.
1984-01-01
A star-tracker telescope, constructed entirely of fused silica elements optically contacted together, has been proposed to provide submilliarc-second pointing accuracy for Gravity Probe. A bibliography and discussion on optical contacting (the bonding of very flat, highly polished surfaces without the use of adhesives) are presented. Then results from preliminary experiments on the strength of optical contacts including a tensile strength test in liquid helium are discussed. Suggestions are made for further study to verify an optical contacting method for the Gravity Probe star-tracker telescope.
2016-09-19
REPORT TYPE 3. DATES COVERED (From - To) 21-10-16 Conference Proceedings 10/2015 – 03/2016 4. TITLE AND SUBTITLE Which eye tracker is right for...Force Research Laboratory 711th Human Performance Wing Airman Systems Directorate Warfighter Interface Division Applied Neuroscience Branch Wright...88ABW-2016-1334; Human Factors and Ergonomics Society 2016 Annual Meeting 19 – 23 Sept 2016 14. Though not often mentioned, the price point of many
Radiation-Hard Breadboard Star Tracker. Attachment 1.
1985-09-01
fdL RETURN DONE !! * . *• , . -+., -• -: . . E+ . . .. j , ’ - - V.r.*r - , It - ’Cjf0 Q -****r.. ... " * *. " . -. tu ’ * Checkadapt 3- 2"Jj...TRACK POSITION, it will use the 3 70! CURRENT STAR #, X POSITION, Y POSITION for 5180 ! information sent to the tracker interface. 7_390 5t0 0 Track _it...CRITERIA which is currently defines as the number of times 57 20 ! the tracker will try and track the star before it is dropped, 5730 it will also
Star tracker error analysis: Roll-to-pitch nonorthogonality
NASA Technical Reports Server (NTRS)
Corson, R. W.
1979-01-01
An error analysis is described on an anomaly isolated in the star tracker software line of sight (LOS) rate test. The LOS rate cosine was found to be greater than one in certain cases which implied that either one or both of the star tracker measured end point unit vectors used to compute the LOS rate cosine had lengths greater than unity. The roll/pitch nonorthogonality matrix in the TNB CL module of the IMU software is examined as the source of error.
NASA Astrophysics Data System (ADS)
Lee, Jae-Yong; Kim, Hyo-Jun; Kim, Young-Joo
2016-02-01
A semi-transparent screen with hemisphere micro-patterns was proposed and designed to enhance the brightness uniformity of the display image toward the driver for a direct-view type head-up display. The hemisphere micro-patterns were designed to consider the inclined angle of the windshield for efficient reflection and scattering toward to the driver. The density and radius of the hemisphere micro-patterns were adjusted as a function of position on the screen based on the geometrical calculation and analyzed by the commercial optical simulation tool based on a ray-tracing method. The designed hemisphere micro-patterns was fabricated by the thermal reflow method and evaluated to confirm the uniform illumination. From the results, the semi-transparent screen with variable micro-patterns shows the 91.9 % of brightness uniformity with the enhanced luminance compare to a screen without micro-patterns. A luminance of fabricated screen also shows good agreement with the simulation result to reflect the clear and bright driving information to the driver.
Schiebel, Johannes; Radeva, Nedyalka; Köster, Helene; Metz, Alexander; Krotzky, Timo; Kuhnert, Maren; Diederich, Wibke E; Heine, Andreas; Neumann, Lars; Atmanene, Cedric; Roecklin, Dominique; Vivat-Hannah, Valérie; Renaud, Jean-Paul; Meinecke, Robert; Schlinck, Nina; Sitte, Astrid; Popp, Franziska; Zeeb, Markus; Klebe, Gerhard
2015-09-01
Fragment-based lead discovery is gaining momentum in drug development. Typically, a hierarchical cascade of several screening techniques is consulted to identify fragment hits which are then analyzed by crystallography. Because crystal structures with bound fragments are essential for the subsequent hit-to-lead-to-drug optimization, the screening process should distinguish reliably between binders and non-binders. We therefore investigated whether different screening methods would reveal similar collections of putative binders. First we used a biochemical assay to identify fragments that bind to endothiapepsin, a surrogate for disease-relevant aspartic proteases. In a comprehensive screening approach, we then evaluated our 361-entry library by using a reporter-displacement assay, saturation-transfer difference NMR, native mass spectrometry, thermophoresis, and a thermal shift assay. While the combined results of these screening methods retrieve 10 of the 11 crystal structures originally predicted by the biochemical assay, the mutual overlap of individual hit lists is surprisingly low, highlighting that each technique operates on different biophysical principles and conditions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lewis, Dawna E; Smith, Nicholas A; Spalding, Jody L; Valente, Daniel L
Visual information from talkers facilitates speech intelligibility for listeners when audibility is challenged by environmental noise and hearing loss. Less is known about how listeners actively process and attend to visual information from different talkers in complex multi-talker environments. This study tracked looking behavior in children with normal hearing (NH), mild bilateral hearing loss (MBHL), and unilateral hearing loss (UHL) in a complex multi-talker environment to examine the extent to which children look at talkers and whether looking patterns relate to performance on a speech-understanding task. It was hypothesized that performance would decrease as perceptual complexity increased and that children with hearing loss would perform more poorly than their peers with NH. Children with MBHL or UHL were expected to demonstrate greater attention to individual talkers during multi-talker exchanges, indicating that they were more likely to attempt to use visual information from talkers to assist in speech understanding in adverse acoustics. It also was of interest to examine whether MBHL, versus UHL, would differentially affect performance and looking behavior. Eighteen children with NH, eight children with MBHL, and 10 children with UHL participated (8-12 years). They followed audiovisual instructions for placing objects on a mat under three conditions: a single talker providing instructions via a video monitor, four possible talkers alternately providing instructions on separate monitors in front of the listener, and the same four talkers providing both target and nontarget information. Multi-talker background noise was presented at a 5 dB signal-to-noise ratio during testing. An eye tracker monitored looking behavior while children performed the experimental task. Behavioral task performance was higher for children with NH than for either group of children with hearing loss. There were no differences in performance between children with UHL and children with MBHL. Eye-tracker analysis revealed that children with NH looked more at the screens overall than did children with MBHL or UHL, though individual differences were greater in the groups with hearing loss. Listeners in all groups spent a small proportion of time looking at relevant screens as talkers spoke. Although looking was distributed across all screens, there was a bias toward the right side of the display. There was no relationship between overall looking behavior and performance on the task. The present study examined the processing of audiovisual speech in the context of a naturalistic task. Results demonstrated that children distributed their looking to a variety of sources during the task, but that children with NH were more likely to look at screens than were those with MBHL/UHL. However, all groups looked at the relevant talkers as they were speaking only a small proportion of the time. Despite variability in looking behavior, listeners were able to follow the audiovisual instructions and children with NH demonstrated better performance than children with MBHL/UHL. These results suggest that performance on some challenging multi-talker audiovisual tasks is not dependent on visual fixation to relevant talkers for children with NH or with MBHL/UHL.
NASA Astrophysics Data System (ADS)
Baysal, Gulcin; Kalav, Berdan; Karagüzel Kayaoğlu, Burçak
2017-10-01
In the current study, it is aimed to determine the effect of pigment concentration on fastness and colour values of thermal and ultraviolet (UV) curable pigment printing on synthetic leather. For this purpose, thermal curable solvent-based and UV curable water-based formulations were prepared with different pigment concentrations (3, 5 and 7%) separately and applied by screen printing technique using a screen printing machine. Samples printed with solvent-based formulations were thermally cured and samples printed with water-based formulations were cured using a UV curing machine equipped with gallium and mercury (Ga/Hg) lamps at room temperature. The crock fastness values of samples printed with solvent-based formulations showed that increase in pigment concentration was not effective on both dry and wet crock fastness values. On the other hand, in samples printed with UV curable water-based formulations, dry crock fastness was improved and evaluated as very good for all pigment concentrations. However, increasing the pigment concentration affected the wet crock fastness values adversely and lower values were observed. As the energy level increased for each irradiation source, the fastness values were improved. In comparison with samples printed with solvent-based formulations, samples printed with UV curable water-based formulations yielded higher K/S values at all pigment concentrations. The results suggested that, higher K/S values can be obtained in samples printed with UV curable water-based formulations at a lower pigment concentration compared to samples printed with solvent-based formulations.
NASA Astrophysics Data System (ADS)
Bowman, Cheryl L.; Jaworske, Donald A.; Stanford, Malcolm K.; Persinger, Justin A.; Khorsandi, Behrooz; Blue, Thomas E.
2007-01-01
The development of a nuclear power system for space missions, such as the Jupiter Icy Moons Orbiter or a lunar outpost, requires substantially more compact reactor design than conventional terrestrial systems. In order to minimize shielding requirements and hence system weight, the radiation tolerance of component materials within the power conversion and heat rejection systems must be defined. Two classes of coatings, thermal control paints and solid lubricants, were identified as material systems for which limited radiation hardness information was available. Screening studies were designed to explore candidate coatings under a predominately fast neutron spectrum. The Ohio State Research Reactor Facility staff performed irradiation in a well characterized, mixed energy spectrum and performed post irradiation analysis of representative coatings for thermal control and solid lubricant applications. Thermal control paints were evaluated for 1 MeV equivalent fluences from 1013 to 1015 n/cm2. No optical degradation was noted although some adhesive degradation was found at higher fluence levels. Solid lubricant coatings were evaluated for 1 MeV equivalent fluences from 1015 to 1016 n/cm2 with coating adhesion and flexibility used for post irradiation evaluation screening. The exposures studied did not lead to obvious property degradation indicating the coatings would have survived the radiation environment for the previously proposed Jupiter mission. The results are also applicable to space power development programs such as fission surface power for future lunar and Mars missions.
NASA Technical Reports Server (NTRS)
Bowman, Cheryl L.; Jaworske, Donald A.; Stanford, Malcolm K.; Persinger, Justin A.; Khorsandi, Behrooz; Blue, Thomas E.
2007-01-01
The development of a nuclear power system for space missions, such as the Jupiter Icy Moons Orbiter or a lunar outpost, requires substantially more compact reactor design than conventional terrestrial systems. In order to minimize shielding requirements and hence system weight, the radiation tolerance of component materials within the power conversion and heat rejection systems must be defined. Two classes of coatings, thermal control paints and solid lubricants, were identified as material systems for which limited radiation hardness information was available. Screening studies were designed to explore candidate coatings under a predominately fast neutron spectrum. The Ohio State Research Reactor Facility staff performed irradiation in a well characterized, mixed energy spectrum and performed post irradiation analysis of representative coatings for thermal control and solid lubricant applications. Thermal control paints were evaluated for 1 MeV equivalent fluences from 10(exp 13) to 10(exp 15) n per square centimeters. No optical degradation was noted although some adhesive degradation was found at higher fluence levels. Solid lubricant coatings were evaluated for 1 MeV equivalent fluences from 10(exp 15) to 10(exp 16) n per square centimeters with coating adhesion and flexibility used for post irradiation evaluation screening. The exposures studied did not lead to obvious property degradation indicating the coatings would have survived the radiation environment for the previously proposed Jupiter mission. The results are also applicable to space power development programs such as fission surface power for future lunar and Mars missions.
High-throughput cocrystal slurry screening by use of in situ Raman microscopy and multi-well plate.
Kojima, Takashi; Tsutsumi, Shunichirou; Yamamoto, Katsuhiko; Ikeda, Yukihiro; Moriwaki, Toshiya
2010-10-31
Cocrystal has attracted much attention in order to improve poor physicochemical properties, since cocrystal former crystallize with the ionic drugs as well as nonionic drugs. Cocrystal screening was usually conducted by crystallization, slurry and co-grinding techniques, however sensitivity, cost and time for screening were limited because of issues such as dissociation of cocrystal during crystallization and cost and time required for slurry and co-grinding methods. To overcome these issues, novel high-throughput cocrystal slurry screening was developed by using in situ Raman microscope and a multi-well plate. Cocrystal screening of indomethacin was conducted with 46 cocrystal formers and potential cocrystals were prepared on a large scale for the characterization with powder X-ray diffractometry, thermal analysis, and Raman microscopy and (1)H NMR spectroscopy. Compared with the characterization of scale-up cocrystals, the cocrystal screening indicated that indomethacin structured novel cocrystals with D/L-mandelic acid, nicotinamide, lactamide and benzamide which was not obtained in the screening with crystallization technique previously reported. In addition, the screening provided not only information of cocrystal formation within a day but also information of equilibrium of cocrystal formation and polymorphic transformation in one screening. Information obtained in this screening allows effective solid form selection by saving cost and time for the development. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Nesbitt, James A.; McCue, Terry R.; Barrett, Charles A.; Miller, Robert A.
2002-01-01
Ceramic thermal barrier coatings will play an increasingly important role in advanced gas turbine engines because of their ability to enable further increases in engine temperatures. However, the coating performance and durability become a major concern under the increasingly harsh thermal cycling conditions. Advanced zirconia- and hafnia-based cluster oxide thermal barrier coatings with lower thermal conductivity and improved thermal stability are being developed using a high-heat-flux laser-rig based test approach. Although the new composition coatings were not yet optimized for cyclic durability, an initial durability screening of numerous candidate coating materials was carried out using conventional furnace cyclic tests. In this paper, furnace thermal cyclic behavior of the advanced plasma-sprayed zirconia-yttria-based thermal barrier coatings that were co-doped with multi-component rare earth oxides was investigated at 1163 C using 45 min hot cycles. The ceramic coating failure mechanisms were studied by using scanning electron microscopy combined with X-ray diffraction phase analysis after the furnace tests. The coating cyclic lifetime will be discussed in relation to coating phase structures, total dopant concentrations, and other properties.
40 CFR 240.207-2 - Recommended procedures: Design.
Code of Federal Regulations, 2010 CFR
2010-07-01
....207-2 Section 240.207-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures... attractive. The tipping, residue discharge, and waste salvage areas should be screened from public view, and...
Autonomous star sensor ASTRO APS: flight experience on Alphasat
NASA Astrophysics Data System (ADS)
Schmidt, U.; Fiksel, T.; Kwiatkowski, A.; Steinbach, I.; Pradarutti, B.; Michel, K.; Benzi, E.
2015-06-01
Jena-Optronik GmbH, located in Jena/Germany, has profound experience in designing and manufacturing star trackers since the early 80s. Today the company has a worldwide leading position in supplying geo-stationary and Earth observation satellites with robust and reliable star tracker systems. In the first decade of the new century Jena-Optronik received a development contract (17317/2003/F/WE) from the European Space Agency to establish the technologically challenging elements for which advanced star tracker technologies as CMOS Active Pixel Sensors were being introduced or were considered strategic. This activity was performed in the frame of the Alphabus large platform pre-development lead by ESA and the industrial Joint Project Team consisting of Astrium (now Airbus Defence and Space), Thales Alenia Space and CNES (Centre national d'études spatiales). The new autonomous star tracker, ASTRO APS (Active Pixel Sensor), extends the Jena-Optronik A stro-series CCD-based star tracker products taken the full benefit of the CMOS APS technology. ASTRO APS is a fully autonomous compact star tracker carrying either the space-qualified radiation hard STAR1000 or the HAS2 APS detectors. The star tracker is one of four Technology Demonstration Payloads (TDP6) carried by Alphasat as hosted payload in the frame of a successful Private Public Partnership between ESA and Inmarsat who owns and operates the satellite as part of its geo-stationary communication satellites fleet. TDP6 supports also directly TDP1, a Laser Communication Terminal, for fine pointing tasks. Alphasat was flawlessly brought in orbit at the end of July 2013 by a European Ariane 5 launcher. Only a few hours after launch the star tracker received its switch ON command and acquired nominally within 6 s the inertial 3-axes attitude. In the following days of the early in-orbit operations of Alphasat the TDP6 unit tracked reliably all the spacecraft maneuvers including the 0.1 and 0.2°/s spin stabilization for Sun pointing, all of the apogee engine thrusts, Moon field of view transits and recovered to stable tracking after several Earth and Sun blindings before the spacecraft entered a preliminary Earth pointing in a nominal geo-stationary attitude. The Jena-Optronik TDP6 operation center received daily the star tracker status and attitude data. The huge amount of acquired raw data has been evaluated to characterize the ASTRO APS (STAR1000) star tracker in-orbit performance. The paper will present in detail these data processing activities and will show the extraordinary good results. Due to the diverse transfer orbit satellite operations the key performance star tracker data like attitude random noise, single star noise, star brightness measurement, baffle Sun exclusion angle, temperature control, etc., could be derived and have been compared to the ground based laboratory and field measurements. The ultimate performance parameters achieved and verified as well as the lessons learned from the comparison to the ground test data are summarized in the conclusion of the paper.
Silver-Teflon coating improvement
NASA Technical Reports Server (NTRS)
Reed, M. W.
1976-01-01
Approximately forty adhesives were subjected to laboratory screening. Seven candidate adhesives were selected from the screening tests and evaluated in a thermal vacuum test on radiator panels similar to the anticipated flight hardware configuration. Several classes of adhesives based on epoxide, polyester, silicone, and urethane resin systems were tested. These included contact adhesives, heat cured adhesives, heat and pressure cured adhesives, pressure sensitive adhesives, and two part paint-on or spray-on adhesives. The panels were tested in a space environmental simulation laboratory chamber during the July 9-20, 1973 time span.
Screen-Cage Ion Plating Of Silver On Polycrystalline Alumina
NASA Technical Reports Server (NTRS)
Spalvins, Talivaldis; Sliney, Harold E.; Deadmore, Daniel L.
1995-01-01
Screen-cage ion plating (SCIP) cost-effective technique offering high throwing power for deposition of adherent metal films on ceramic substrates. Applies silver films to complexly shaped substrates of polycrystalline alumina. Silver adheres tenaciously and reduces friction. SCIP holds promise for applying lubricating soft metallic films to high-temperature ceramic components of advanced combustion engines. Other potential uses include coating substrates with metal for protection against corrosion, depositing electrical conductors on dielectric substrates, making optically reflective or electrically or thermally conductive surface layers, and applying decorative metal coats to ceramic trophies or sculptures.
Star Identification Without Attitude Knowledge: Testing with X-Ray Timing Experiment Data
NASA Technical Reports Server (NTRS)
Ketchum, Eleanor
1997-01-01
As the budget for the scientific exploration of space shrinks, the need for more autonomous spacecraft increases. For a spacecraft with a star tracker, the ability to determinate attitude from a lost in space state autonomously requires the capability to identify the stars in the field of view of the tracker. Although there have been efforts to produce autonomous star trackers which perform this function internally, many programs cannot afford these sensors. The author previously presented a method for identifying stars without a priori attitude knowledge specifically targeted for onboard computers as it minimizes the necessary computer storage. The method has previously been tested with simulated data. This paper provides results of star identification without a priori attitude knowledge using flight data from two 8 by 8 degree charge coupled device star trackers onboard the X-Ray Timing Experiment.
A Brightness-Referenced Star Identification Algorithm for APS Star Trackers
Zhang, Peng; Zhao, Qile; Liu, Jingnan; Liu, Ning
2014-01-01
Star trackers are currently the most accurate spacecraft attitude sensors. As a result, they are widely used in remote sensing satellites. Since traditional charge-coupled device (CCD)-based star trackers have a limited sensitivity range and dynamic range, the matching process for a star tracker is typically not very sensitive to star brightness. For active pixel sensor (APS) star trackers, the intensity of an imaged star is valuable information that can be used in star identification process. In this paper an improved brightness referenced star identification algorithm is presented. This algorithm utilizes the k-vector search theory and adds imaged stars' intensities to narrow the search scope and therefore increase the efficiency of the matching process. Based on different imaging conditions (slew, bright bodies, etc.) the developed matching algorithm operates in one of two identification modes: a three-star mode, and a four-star mode. If the reference bright stars (the stars brighter than three magnitude) show up, the algorithm runs the three-star mode and efficiency is further improved. The proposed method was compared with other two distinctive methods the pyramid and geometric voting methods. All three methods were tested with simulation data and actual in orbit data from the APS star tracker of ZY-3. Using a catalog composed of 1500 stars, the results show that without false stars the efficiency of this new method is 4∼5 times that of the pyramid method and 35∼37 times that of the geometric method. PMID:25299950
A brightness-referenced star identification algorithm for APS star trackers.
Zhang, Peng; Zhao, Qile; Liu, Jingnan; Liu, Ning
2014-10-08
Star trackers are currently the most accurate spacecraft attitude sensors. As a result, they are widely used in remote sensing satellites. Since traditional charge-coupled device (CCD)-based star trackers have a limited sensitivity range and dynamic range, the matching process for a star tracker is typically not very sensitive to star brightness. For active pixel sensor (APS) star trackers, the intensity of an imaged star is valuable information that can be used in star identification process. In this paper an improved brightness referenced star identification algorithm is presented. This algorithm utilizes the k-vector search theory and adds imaged stars' intensities to narrow the search scope and therefore increase the efficiency of the matching process. Based on different imaging conditions (slew, bright bodies, etc.) the developed matching algorithm operates in one of two identification modes: a three-star mode, and a four-star mode. If the reference bright stars (the stars brighter than three magnitude) show up, the algorithm runs the three-star mode and efficiency is further improved. The proposed method was compared with other two distinctive methods the pyramid and geometric voting methods. All three methods were tested with simulation data and actual in orbit data from the APS star tracker of ZY-3. Using a catalog composed of 1500 stars, the results show that without false stars the efficiency of this new method is 4~5 times that of the pyramid method and 35~37 times that of the geometric method.
High-Performance Screen-Printed Thermoelectric Films on Fabrics.
Shin, Sunmi; Kumar, Rajan; Roh, Jong Wook; Ko, Dong-Su; Kim, Hyun-Sik; Kim, Sang Il; Yin, Lu; Schlossberg, Sarah M; Cui, Shuang; You, Jung-Min; Kwon, Soonshin; Zheng, Jianlin; Wang, Joseph; Chen, Renkun
2017-08-04
Printing techniques could offer a scalable approach to fabricate thermoelectric (TE) devices on flexible substrates for power generation used in wearable devices and personalized thermo-regulation. However, typical printing processes need a large concentration of binder additives, which often render a detrimental effect on electrical transport of the printed TE layers. Here, we report scalable screen-printing of TE layers on flexible fiber glass fabrics, by rationally optimizing the printing inks consisting of TE particles (p-type Bi 0.5 Sb 1.5 Te 3 or n-type Bi 2 Te 2.7 Se 0.3 ), binders, and organic solvents. We identified a suitable binder additive, methyl cellulose, which offers suitable viscosity for printability at a very small concentration (0.45-0.60 wt.%), thus minimizing its negative impact on electrical transport. Following printing, the binders were subsequently burnt off via sintering and hot pressing. We found that the nanoscale defects left behind after the binder burnt off became effective phonon scattering centers, leading to low lattice thermal conductivity in the printed n-type material. With the high electrical conductivity and low thermal conductivity, the screen-printed TE layers showed high room-temperature ZT values of 0.65 and 0.81 for p-type and n-type, respectively.
Low-G fluid transfer technology study
NASA Technical Reports Server (NTRS)
Stark, J. A.
1976-01-01
Technology gaps and system characteristics critical to cryogenic and noncryogenic in-orbit fluid transfer were identified. Four different supply systems were conceptually designed as space shuttle payloads. These were; (1) space tug supply - LH2, LO2, N2H4, He - linear acceleration for liquid acquisition with supply module and tug separated from shuttle, (2) tug supply using orbiter drag, (3) orbiter supply - N2O4,MMH,He, H2,O2 - surface tension screens, (4) multiple receivers supply 0 solar electric propulsion stage, Hg, diaphragm - HEAO B, HEe, paddle fluid rotation-satellite control section, N2H4, screens. It was found that screens had the best overall potential for low weight and simplicity, however, thermal problems with cryogenics still need final resolution.
NASA Astrophysics Data System (ADS)
Linh, Dang Khanh; Khanh, Nguyen Quoc
2018-03-01
We calculate the zero-temperature conductivity of bilayer graphene (BLG) impacted by Coulomb impurity scattering using four different screening models: unscreened, Thomas-Fermi (TF), overscreened and random phase approximation (RPA). We also calculate the conductivity and thermal conductance of BLG using TF, zero- and finite-temperature RPA screening functions. We find large differences between the results of the models and show that TF and finite-temperature RPA give similar results for diffusion thermopower Sd. Using the finite-temperature RPA, we calculate temperature and density dependence of Sd in BLG on SiO2, HfO2 substrates and suspended BLG for different values of interlayer distance c and distance between the first layer and the substrate d.
Mercer, Kathryn; Giangregorio, Lora; Schneider, Eric; Chilana, Parmit; Li, Melissa; Grindrod, Kelly
2016-01-27
Physical inactivity and sedentary behavior increase the risk of chronic illness and death. The newest generation of "wearable" activity trackers offers potential as a multifaceted intervention to help people become more active. To examine the usability and usefulness of wearable activity trackers for older adults living with chronic illness. We recruited a purposive sample of 32 participants over the age of 50, who had been previously diagnosed with a chronic illness, including vascular disease, diabetes, arthritis, and osteoporosis. Participants were between 52 and 84 years of age (mean 64); among the study participants, 23 (72%) were women and the mean body mass index was 31 kg/m(2). Participants tested 5 trackers, including a simple pedometer (Sportline or Mio) followed by 4 wearable activity trackers (Fitbit Zip, Misfit Shine, Jawbone Up 24, and Withings Pulse) in random order. Selected devices represented the range of wearable products and features available on the Canadian market in 2014. Participants wore each device for at least 3 days and evaluated it using a questionnaire developed from the Technology Acceptance Model. We used focus groups to explore participant experiences and a thematic analysis approach to data collection and analysis. Our study resulted in 4 themes: (1) adoption within a comfort zone; (2) self-awareness and goal setting; (3) purposes of data tracking; and (4) future of wearable activity trackers as health care devices. Prior to enrolling, few participants were aware of wearable activity trackers. Most also had been asked by a physician to exercise more and cited this as a motivation for testing the devices. None of the participants planned to purchase the simple pedometer after the study, citing poor accuracy and data loss, whereas 73% (N=32) planned to purchase a wearable activity tracker. Preferences varied but 50% felt they would buy a Fitbit and 42% felt they would buy a Misfit, Jawbone, or Withings. The simple pedometer had a mean acceptance score of 56/95 compared with 63 for the Withings, 65 for the Misfit and Jawbone, and 68 for the Fitbit. To improve usability, older users may benefit from devices that have better compatibility with personal computers or less-expensive Android mobile phones and tablets, and have comprehensive paper-based user manuals and apps that interpret user data. For older adults living with chronic illness, wearable activity trackers are perceived as useful and acceptable. New users may need support to both set up the device and learn how to interpret their data.
Mercer, Kathryn; Giangregorio, Lora; Schneider, Eric; Chilana, Parmit; Li, Melissa
2016-01-01
Background Physical inactivity and sedentary behavior increase the risk of chronic illness and death. The newest generation of “wearable” activity trackers offers potential as a multifaceted intervention to help people become more active. Objective To examine the usability and usefulness of wearable activity trackers for older adults living with chronic illness. Methods We recruited a purposive sample of 32 participants over the age of 50, who had been previously diagnosed with a chronic illness, including vascular disease, diabetes, arthritis, and osteoporosis. Participants were between 52 and 84 years of age (mean 64); among the study participants, 23 (72%) were women and the mean body mass index was 31 kg/m2. Participants tested 5 trackers, including a simple pedometer (Sportline or Mio) followed by 4 wearable activity trackers (Fitbit Zip, Misfit Shine, Jawbone Up 24, and Withings Pulse) in random order. Selected devices represented the range of wearable products and features available on the Canadian market in 2014. Participants wore each device for at least 3 days and evaluated it using a questionnaire developed from the Technology Acceptance Model. We used focus groups to explore participant experiences and a thematic analysis approach to data collection and analysis. Results Our study resulted in 4 themes: (1) adoption within a comfort zone; (2) self-awareness and goal setting; (3) purposes of data tracking; and (4) future of wearable activity trackers as health care devices. Prior to enrolling, few participants were aware of wearable activity trackers. Most also had been asked by a physician to exercise more and cited this as a motivation for testing the devices. None of the participants planned to purchase the simple pedometer after the study, citing poor accuracy and data loss, whereas 73% (N=32) planned to purchase a wearable activity tracker. Preferences varied but 50% felt they would buy a Fitbit and 42% felt they would buy a Misfit, Jawbone, or Withings. The simple pedometer had a mean acceptance score of 56/95 compared with 63 for the Withings, 65 for the Misfit and Jawbone, and 68 for the Fitbit. To improve usability, older users may benefit from devices that have better compatibility with personal computers or less-expensive Android mobile phones and tablets, and have comprehensive paper-based user manuals and apps that interpret user data. Conclusions For older adults living with chronic illness, wearable activity trackers are perceived as useful and acceptable. New users may need support to both set up the device and learn how to interpret their data. PMID:26818775
Lieffers, Jessica R L; Haresign, Helen; Mehling, Christine; Hanning, Rhona M
2016-09-15
Little is known about use of goal setting and tracking tools within online programs to support nutrition and physical activity behaviour change. In 2011, Dietitians of Canada added "My Goals," a nutrition and physical activity behaviour goal setting and tracking tool to their free publicly available self-monitoring website (eaTracker® ( http://www.eaTracker.ca/ )). My Goals allows users to: a) set "ready-made" SMART (Specific, Measurable, Attainable, Realistic, Time-related) goals (choice of n = 87 goals from n = 13 categories) or "write your own" goals, and b) track progress using the "My Goals Tracker." The purpose of this study was to characterize: a) My Goals user demographics, b) types of goals set, and c) My Goals Tracker use. Anonymous data on all goals set using the My Goals feature from December 6/2012-April 28/2014 by users ≥19y from Ontario and Alberta, Canada were obtained. This dataset contained: anonymous self-reported user demographic data, user set goals, and My Goals Tracker use data. Write your own goals were categorized by topic and specificity. Data were summarized using descriptive statistics. Multivariate binary logistic regression was used to determine associations between user demographics and a) goal topic areas and b) My Goals Tracker use. Overall, n = 16,511 goal statements (75.4 % ready-made; 24.6 % write your own) set by n = 8,067 adult users 19-85y (83.3 % female; mean age 41.1 ± 15.0y, mean BMI 28.8 ± 7.6kg/m(2)) were included for analysis. Overall, 33.1 % of ready-made goals were from the "Managing your Weight" category. Of write your own goal entries, 42.3 % were solely distal goals (most related to weight management); 38.6 % addressed nutrition behaviour change (16.6 % had unspecific general eating goals); 18.1 % addressed physical activity behaviour change (47.3 % had goals without information on exercise amount and type). Many write your own goals were poor quality (e.g., non-specific (e.g., missing amounts)), and possibly unrealistic (e.g., no sugar). Few goals were tracked (<10 %). Demographic variables had statistically significant relations with goal topic areas and My Goals Tracker use. eaTracker® users had high interest in goal setting and the My Goals feature, however, self-written goals were often poor quality and goal tracking was rare. Further research is needed to better support users.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lenihan, Elizabeth M
The objectives of this research were to further characterize exotic by adapted corn inbreds by studying the impact of environment on their starch thermal properties, and investigating the development of starch thermal properties during kernel maturation by using differential scanning calorimetry (DSC). A method to expedite identification of unusual starch thermal traits was investigated by examining five corn kernels at a time, instead of one kernel, which the previous screening methods used. Corn lines with known thermal functions were blended with background starch (control) in ratios of unique starch to control starch, and analyzed by using DSC. Control starch wasmore » representative of typical corn starch. The values for each ratio within a mutant type were unique (α < 0.01) for most DSC measurements. These results supported the five-kernel method for rapidly screening large amounts of corn germplasm to identify unusual starch traits. The effects of 5 growing locations on starch thermal properties from exotic by adapted corn and Corn Belt lines were studied using DSC. The warmest location, Missouri, generally produced starch with greater gelatinization onset temperature (T oG), narrower range of gelatinization (R G), and greater enthalpy of gelatinization (ΔH G). The coolest location, Illinois, generally resulted in starch with lower T oG, wider R G, and lower ΔH G. Starch from the Ames 1 farm had thermal properties similar to those of Illinois, whereas starch from the Ames 2 farm had thermal properties similar to those of Missouri. The temperature at Ames 2 may have been warmer since it was located near a river; however, soil type and quality also were different. Final corn starch structure and function change during development and maturity. Thus, the changes in starch thermal properties during 5 stages of endosperm development from exotic by adapted corn and Corn Belt lines at two locations were studied by using DSC. The T oG tended to decrease during maturation of the kernel, whereas theΔH G tended not to change. Retrogradation parameters did not vary greatly among days after pollination (DAP) and between locations. Genotypes were affected differently by environments and significant interactions were found between genotype, environment,and DAP.« less
Facebook Apps for Smoking Cessation: A Review of Content and Adherence to Evidence-Based Guidelines
2014-01-01
Background Facebook is the most popular social network site, with over 1 billion users globally. There are millions of apps available within Facebook, many of which address health and health behavior change. Facebook may represent a promising channel to reach smokers with cessation interventions via apps. To date, there have been no published reports about Facebook apps for smoking cessation. Objective The purpose of this study was to review the features and functionality of Facebook apps for smoking cessation and to determine the extent to which they adhere to evidence-based guidelines for tobacco dependence treatment. Methods In August 2013, we searched Facebook and three top Internet search engines using smoking cessation keywords to identify relevant Facebook apps. Resultant apps were screened for eligibility (smoking cessation-related, English language, and functioning). Eligible apps were reviewed by 2 independent coders using a standardized coding scheme. Coding included content features (interactive, informational, and social) and adherence to an established 20-item index (possible score 0-40) derived from the US Public Health Service’s Clinical Practice Guidelines for Treating Tobacco Use and Dependence. Results We screened 22 apps for eligibility; of these, 12 underwent full coding. Only 9 apps were available on Facebook. Facebook apps fell into three broad categories: public pledge to quit (n=3), quit-date–based calculator/tracker (n=4), or a multicomponent quit smoking program (n=2). All apps incorporated interactive, informational, and social features except for two quit-date–based calculator/trackers apps (lacked informational component). All apps allowed app-related posting within Facebook (ie, on self/other Facebook profile), and four had a within-app “community” feature to enable app users to communicate with each other. Adherence index summary scores among Facebook apps were low overall (mean 15.1, SD 7.8, range 7-30), with multicomponent apps scoring the highest. Conclusions There are few smoking cessation apps available within Facebook. Among those available, adherence to cessation treatment guidelines was low. Smoking cessation interventions provided via the Facebook platform are a unique and as yet untapped treatment strategy that can harness existing social support and social networks for quitting. Research is needed to examine whether apps that adhere to clinical practice guidelines for tobacco dependence treatment are more effective in promoting cessation than those that do not. PMID:25205129
Facebook apps for smoking cessation: a review of content and adherence to evidence-based guidelines.
Jacobs, Megan A; Cobb, Caroline O; Abroms, Lorien; Graham, Amanda L
2014-09-09
Facebook is the most popular social network site, with over 1 billion users globally. There are millions of apps available within Facebook, many of which address health and health behavior change. Facebook may represent a promising channel to reach smokers with cessation interventions via apps. To date, there have been no published reports about Facebook apps for smoking cessation. The purpose of this study was to review the features and functionality of Facebook apps for smoking cessation and to determine the extent to which they adhere to evidence-based guidelines for tobacco dependence treatment. In August 2013, we searched Facebook and three top Internet search engines using smoking cessation keywords to identify relevant Facebook apps. Resultant apps were screened for eligibility (smoking cessation-related, English language, and functioning). Eligible apps were reviewed by 2 independent coders using a standardized coding scheme. Coding included content features (interactive, informational, and social) and adherence to an established 20-item index (possible score 0-40) derived from the US Public Health Service's Clinical Practice Guidelines for Treating Tobacco Use and Dependence. We screened 22 apps for eligibility; of these, 12 underwent full coding. Only 9 apps were available on Facebook. Facebook apps fell into three broad categories: public pledge to quit (n=3), quit-date-based calculator/tracker (n=4), or a multicomponent quit smoking program (n=2). All apps incorporated interactive, informational, and social features except for two quit-date-based calculator/trackers apps (lacked informational component). All apps allowed app-related posting within Facebook (ie, on self/other Facebook profile), and four had a within-app "community" feature to enable app users to communicate with each other. Adherence index summary scores among Facebook apps were low overall (mean 15.1, SD 7.8, range 7-30), with multicomponent apps scoring the highest. There are few smoking cessation apps available within Facebook. Among those available, adherence to cessation treatment guidelines was low. Smoking cessation interventions provided via the Facebook platform are a unique and as yet untapped treatment strategy that can harness existing social support and social networks for quitting. Research is needed to examine whether apps that adhere to clinical practice guidelines for tobacco dependence treatment are more effective in promoting cessation than those that do not.
jTracker and Monte Carlo Comparison
NASA Astrophysics Data System (ADS)
Selensky, Lauren; SeaQuest/E906 Collaboration
2015-10-01
SeaQuest is designed to observe the characteristics and behavior of `sea-quarks' in a proton by reconstructing them from the subatomic particles produced in a collision. The 120 GeV beam from the main injector collides with a fixed target and then passes through a series of detectors which records information about the particles produced in the collision. However, this data becomes meaningful only after it has been processed, stored, analyzed, and interpreted. Several programs are involved in this process. jTracker (sqerp) reads wire or hodoscope hits and reconstructs the tracks of potential dimuon pairs from a run, and Geant4 Monte Carlo simulates dimuon production and background noise from the beam. During track reconstruction, an event must meet the criteria set by the tracker to be considered a viable dimuon pair; this ensures that relevant data is retained. As a check, a comparison between a new version of jTracker and Monte Carlo was made in order to see how accurately jTracker could reconstruct the events created by Monte Carlo. In this presentation, the results of the inquest and their potential effects on the programming will be shown. This work is supported by U.S. DOE MENP Grant DE-FG02-03ER41243.
Encoding color information for visual tracking: Algorithms and benchmark.
Liang, Pengpeng; Blasch, Erik; Ling, Haibin
2015-12-01
While color information is known to provide rich discriminative clues for visual inference, most modern visual trackers limit themselves to the grayscale realm. Despite recent efforts to integrate color in tracking, there is a lack of comprehensive understanding of the role color information can play. In this paper, we attack this problem by conducting a systematic study from both the algorithm and benchmark perspectives. On the algorithm side, we comprehensively encode 10 chromatic models into 16 carefully selected state-of-the-art visual trackers. On the benchmark side, we compile a large set of 128 color sequences with ground truth and challenge factor annotations (e.g., occlusion). A thorough evaluation is conducted by running all the color-encoded trackers, together with two recently proposed color trackers. A further validation is conducted on an RGBD tracking benchmark. The results clearly show the benefit of encoding color information for tracking. We also perform detailed analysis on several issues, including the behavior of various combinations between color model and visual tracker, the degree of difficulty of each sequence for tracking, and how different challenge factors affect the tracking performance. We expect the study to provide the guidance, motivation, and benchmark for future work on encoding color in visual tracking.
Measurement of thermal conductivity and thermal diffusivity using a thermoelectric module
NASA Astrophysics Data System (ADS)
Beltrán-Pitarch, Braulio; Márquez-García, Lourdes; Min, Gao; García-Cañadas, Jorge
2017-04-01
A proof of concept of using a thermoelectric module to measure both thermal conductivity and thermal diffusivity of bulk disc samples at room temperature is demonstrated. The method involves the calculation of the integral area from an impedance spectrum, which empirically correlates with the thermal properties of the sample through an exponential relationship. This relationship was obtained employing different reference materials. The impedance spectroscopy measurements are performed in a very simple setup, comprising a thermoelectric module, which is soldered at its bottom side to a Cu block (heat sink) and thermally connected with the sample at its top side employing thermal grease. Random and systematic errors of the method were calculated for the thermal conductivity (18.6% and 10.9%, respectively) and thermal diffusivity (14.2% and 14.7%, respectively) employing a BCR724 standard reference material. Although errors are somewhat high, the technique could be useful for screening purposes or high-throughput measurements at its current state. This new method establishes a new application for thermoelectric modules as thermal properties sensors. It involves the use of a very simple setup in conjunction with a frequency response analyzer, which provides a low cost alternative to most of currently available apparatus in the market. In addition, impedance analyzers are reliable and widely spread equipment, which facilities the sometimes difficult access to thermal conductivity facilities.
Intelligent modular star and target tracker: a new generation of attitude sensors
NASA Astrophysics Data System (ADS)
Schmidt, Uwe; Strobel, Rainer; Wunder, Dietmar; Graf, Eberhart
2018-04-01
This paper, "Intelligent modular star and target tracker: a new generation of attitude sensors," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
NASA Technical Reports Server (NTRS)
1988-01-01
Hughes Aircraft Corporation's Probeye Model 3300 Thermal Video System consists of tripod mounted infrared scanner that detects the degree of heat emitted by an object and a TV monitor on which results are displayed. Latest addition to Hughes line of infrared medical applications can detect temperature variations as fine as one-tenth of a degree centigrade. Thermography, proving to be a valuable screening tool in diagnosis, can produce information to preclude necessity of performing more invasive tests that may be painful and hazardous. Also useful in verifying a patient's progress through therapy and rehabilitation.
Retroreflector field tracker. [noncontact optical position sensor for space application
NASA Technical Reports Server (NTRS)
Wargocki, F. E.; Ray, A. J.; Hall, G. E.
1984-01-01
An electrooptical position-measuring instrument, the Retroreflector Field Tracker or RFT, is described. It is part of the Dynamic Augmentation Experiment - a part of the payload of Space Shuttle flight 41-D in Summer 1984. The tracker measures and outputs the position of 23 reflective targets placed on a 32-m solar array to provide data for determination of the dynamics of the lightweight structure. The sensor uses a 256 x 256 pixel CID detector; the processor electronics include three Z-80 microprocessors. A pulsed laser diode illuminator is used.
Sense of presence and anxiety during virtual social interactions between a human and virtual humans.
Morina, Nexhmedin; Brinkman, Willem-Paul; Hartanto, Dwi; Emmelkamp, Paul M G
2014-01-01
Virtual reality exposure therapy (VRET) has been shown to be effective in treatment of anxiety disorders. Yet, there is lack of research on the extent to which interaction between the individual and virtual humans can be successfully implanted to increase levels of anxiety for therapeutic purposes. This proof-of-concept pilot study aimed at examining levels of the sense of presence and anxiety during exposure to virtual environments involving social interaction with virtual humans and using different virtual reality displays. A non-clinical sample of 38 participants was randomly assigned to either a head-mounted display (HMD) with motion tracker and sterescopic view condition or a one-screen projection-based virtual reality display condition. Participants in both conditions engaged in free speech dialogues with virtual humans controlled by research assistants. It was hypothesized that exposure to virtual social interactions will elicit moderate levels of sense of presence and anxiety in both groups. Further it was expected that participants in the HMD condition will report higher scores of sense of presence and anxiety than participants in the one-screen projection-based display condition. Results revealed that in both conditions virtual social interactions were associated with moderate levels of sense of presence and anxiety. Additionally, participants in the HMD condition reported significantly higher levels of presence than those in the one-screen projection-based display condition (p = .001). However, contrary to the expectations neither the average level of anxiety nor the highest level of anxiety during exposure to social virtual environments differed between the groups (p = .97 and p = .75, respectively). The findings suggest that virtual social interactions can be successfully applied in VRET to enhance sense of presence and anxiety. Furthermore, our results indicate that one-screen projection-based displays can successfully activate levels of anxiety in social virtual environments. The outcome can prove helpful in using low-cost projection-based virtual reality environments for treating individuals with social phobia.
Morrison, Leanne G; Hargood, Charlie; Lin, Sharon Xiaowen; Dennison, Laura; Joseph, Judith; Hughes, Stephanie; Michaelides, Danius T; Johnston, Derek; Johnston, Marie; Michie, Susan; Little, Paul; Smith, Peter Wf; Weal, Mark J; Yardley, Lucy
2014-10-22
Advancements in mobile phone technology offer huge potential for enhancing the timely delivery of health behavior change interventions. The development of smartphone-based health interventions (apps) is a rapidly growing field of research, yet there have been few longitudinal examinations of how people experience and use these apps within their day-to-day routines, particularly within the context of a hybrid Web- and app-based intervention. This study used an in-depth mixed-methods design to examine individual variation in (1) impact on self-reported goal engagement (ie, motivation, self-efficacy, awareness, effort, achievement) of access to a weight management app (POWeR Tracker) when provided alongside a Web-based weight management intervention (POWeR) and (2) usage and views of POWeR Tracker. Thirteen adults were provided access to POWeR and were monitored over a 4-week period. Access to POWeR Tracker was provided in 2 alternate weeks (ie, weeks 1 and 3 or weeks 2 and 4). Participants' goal engagement was measured daily via self-report. Mixed effects models were used to examine change in goal engagement between the weeks when POWeR Tracker was and was not available and whether the extent of change in goal engagement varied between individual participants. Usage of POWeR and POWeR Tracker was automatically recorded for each participant. Telephone interviews were conducted and analyzed using inductive thematic analysis to further explore participants' experiences using POWeR and POWeR Tracker. Access to POWeR Tracker was associated with a significant increase in participants' awareness of their eating (β1=0.31, P=.04) and physical activity goals (β1=0.28, P=.03). The level of increase varied between individual participants. Usage data showed that participants used the POWeR website for similar amounts of time during the weeks when POWeR Tracker was (mean 29 minutes, SD 31 minutes) and was not available (mean 27 minutes, SD 33 minutes). POWeR Tracker was mostly accessed in short bursts (mean 3 minutes, SD 2 minutes) during convenient moments or moments when participants deemed the intervention content most relevant. The qualitative data indicated that nearly all participants agreed that it was more convenient to access information on-the-go via their mobiles compared to a computer. However, participants varied in their views and usage of the Web- versus app-based components and the informational versus tracking tools provided by POWeR Tracker. This study provides evidence that smartphones have the potential to improve individuals' engagement with their health-related goals when used as a supplement to an existing online intervention. The perceived convenience of mobile access to information does not appear to deter use of Web-based interventions or strengthen the impact of app access on goal engagement. A mixed-methods design enabled exploration of individual variation in daily usage of the app-based tools.
Hargood, Charlie; Lin, Sharon Xiaowen; Dennison, Laura; Joseph, Judith; Hughes, Stephanie; Michaelides, Danius T; Johnston, Derek; Johnston, Marie; Michie, Susan; Little, Paul; Smith, Peter WF; Weal, Mark J; Yardley, Lucy
2014-01-01
Background Advancements in mobile phone technology offer huge potential for enhancing the timely delivery of health behavior change interventions. The development of smartphone-based health interventions (apps) is a rapidly growing field of research, yet there have been few longitudinal examinations of how people experience and use these apps within their day-to-day routines, particularly within the context of a hybrid Web- and app-based intervention. Objective This study used an in-depth mixed-methods design to examine individual variation in (1) impact on self-reported goal engagement (ie, motivation, self-efficacy, awareness, effort, achievement) of access to a weight management app (POWeR Tracker) when provided alongside a Web-based weight management intervention (POWeR) and (2) usage and views of POWeR Tracker. Methods Thirteen adults were provided access to POWeR and were monitored over a 4-week period. Access to POWeR Tracker was provided in 2 alternate weeks (ie, weeks 1 and 3 or weeks 2 and 4). Participants’ goal engagement was measured daily via self-report. Mixed effects models were used to examine change in goal engagement between the weeks when POWeR Tracker was and was not available and whether the extent of change in goal engagement varied between individual participants. Usage of POWeR and POWeR Tracker was automatically recorded for each participant. Telephone interviews were conducted and analyzed using inductive thematic analysis to further explore participants’ experiences using POWeR and POWeR Tracker. Results Access to POWeR Tracker was associated with a significant increase in participants’ awareness of their eating (β1=0.31, P=.04) and physical activity goals (β1=0.28, P=.03). The level of increase varied between individual participants. Usage data showed that participants used the POWeR website for similar amounts of time during the weeks when POWeR Tracker was (mean 29 minutes, SD 31 minutes) and was not available (mean 27 minutes, SD 33 minutes). POWeR Tracker was mostly accessed in short bursts (mean 3 minutes, SD 2 minutes) during convenient moments or moments when participants deemed the intervention content most relevant. The qualitative data indicated that nearly all participants agreed that it was more convenient to access information on-the-go via their mobiles compared to a computer. However, participants varied in their views and usage of the Web- versus app-based components and the informational versus tracking tools provided by POWeR Tracker. Conclusions This study provides evidence that smartphones have the potential to improve individuals’ engagement with their health-related goals when used as a supplement to an existing online intervention. The perceived convenience of mobile access to information does not appear to deter use of Web-based interventions or strengthen the impact of app access on goal engagement. A mixed-methods design enabled exploration of individual variation in daily usage of the app-based tools. PMID:25355131
Examining the role of dopamine D2 and D3 receptors in Pavlovian conditioned approach behaviors.
Fraser, Kurt M; Haight, Joshua L; Gardner, Eliot L; Flagel, Shelly B
2016-05-15
Elucidating the neurobiological mechanisms underlying individual differences in the extent to which reward cues acquire the ability to act as incentive stimuli may contribute to the development of successful treatments for addiction and related disorders. We used the sign-tracker/goal-tracker animal model to examine the role of dopamine D2 and D3 receptors in the propensity to attribute incentive salience to reward cues. Following Pavlovian training, wherein a discrete lever-cue was paired with food reward, rats were classified as sign- or goal-trackers based on the resultant conditioned response. We examined the effects of D2/D3 agonists, 7-OH-DPAT (0.01-0.32mg/kg) or pramipexole (0.032-0.32mg/kg), the D2/D3 antagonist raclopride (0.1mg/kg), and the selective D3 antagonist, SB-277011A (6 or 24mg/kg), on the expression of sign- and goal-tracking conditioned responses. The lever-cue acquired predictive value and elicited a conditioned response for sign- and goal-trackers, but only for sign-trackers did it also acquire incentive value. Following administration of either 7-OH-DPAT, pramipexole, or raclopride, the performance of the previously acquired conditioned response was attenuated for both sign- and goal-trackers. For sign-trackers, the D2/D3 agonist, 7-OH-DPAT, also attenuated the conditioned reinforcing properties of the lever-cue. The selective D3 antagonist did not affect either conditioned response. Alterations in D2/D3 receptor signaling, but not D3 signaling alone, transiently attenuate a previously acquired Pavlovian conditioned response, regardless of whether the response is a result of incentive motivational processes. These findings suggest activity at the dopamine D2 receptor is critical for a reward cue to maintain either its incentive or predictive qualities. Copyright © 2016 Elsevier B.V. All rights reserved.
A refined technique to calculate finite helical axes from rigid body trackers.
McLachlin, Stewart D; Ferreira, Louis M; Dunning, Cynthia E
2014-12-01
Finite helical axes (FHAs) are a potentially effective tool for joint kinematic analysis. Unfortunately, no straightforward guidelines exist for calculating accurate FHAs using prepackaged six degree-of-freedom (6 DOF) rigid body trackers. Thus, this study aimed to: (1) describe a protocol for calculating FHA parameters from 6 DOF rigid body trackers using the screw matrix and (2) to maximize the number of accurate FHAs generated from a given data set using a moving window analysis. Four Optotrak® Smart Markers were used as the rigid body trackers, two moving and two fixed, at different distances from the hinge joint of a custom-machined jig. 6D OF pose information was generated from 51 static positions of the jig rotated and fixed in 0.5 deg increments up to 25 deg. Output metrics included the FHA direction cosines, the rotation about the FHA, the translation along the axis, and the intercept of the FHA with the plane normal to the jig's hinge joint. FHA metrics were calculated using the relative tracker rotation from the starting position, and using a moving window analysis to define a minimum acceptable rotational displacement between the moving tracker data points. Data analysis found all FHA rotations calculated from the starting position were within 0.15 deg of the prescribed jig rotation. FHA intercepts were most stable when determined using trackers closest to the hinge axis. Increasing the moving window size improved the FHA direction cosines and center of rotation accuracy. Window sizes larger than 2 deg had an intercept deviation of less than 1 mm. Furthermore, compared to the 0 deg window size, the 2 deg window had a 90% improvement in FHA intercept precision while generating almost an equivalent number of FHA axes. This work identified a solution to improve FHA calculations for biomechanical researchers looking to describe changes in 3D joint motion.
Deep coupling of star tracker and MEMS-gyro data under highly dynamic and long exposure conditions
NASA Astrophysics Data System (ADS)
Sun, Ting; Xing, Fei; You, Zheng; Wang, Xiaochu; Li, Bin
2014-08-01
Star trackers and gyroscopes are the two most widely used attitude measurement devices in spacecrafts. The star tracker is supposed to have the highest accuracy in stable conditions among different types of attitude measurement devices. In general, to detect faint stars and reduce the size of the star tracker, a method with long exposure time method is usually used. Thus, under dynamic conditions, smearing of the star image may appear and result in decreased accuracy or even failed extraction of the star spot. This may cause inaccuracies in attitude measurement. Gyros have relatively good dynamic performance and are usually used in combination with star trackers. However, current combination methods focus mainly on the data fusion of the output attitude data levels, which are inadequate for utilizing and processing internal blurred star image information. A method for tracking deep coupling stars and MEMS-gyro data is proposed in this work. The method achieves deep fusion at the star image level. First, dynamic star image processing is performed based on the angular velocity information of the MEMS-gyro. Signal-to-noise ratio (SNR) of the star spot could be improved, and extraction is achieved more effectively. Then, a prediction model for optimal estimation of the star spot position is obtained through the MEMS-gyro, and an extended Kalman filter is introduced. Meanwhile, the MEMS-gyro drift can be estimated and compensated though the proposed method. These enable the star tracker to achieve high star centroid determination accuracy under dynamic conditions. The MEMS-gyro drift can be corrected even when attitude data of the star tracker are unable to be solved and only one navigation star is captured in the field of view. Laboratory experiments were performed to verify the effectiveness of the proposed method and the whole system.
Examining the Role of Dopamine D2 and D3 Receptors in Pavlovian Conditioned Approach Behaviors
Fraser, Kurt M.; Haight, Joshua L.; Gardner, Eliot L.; Flagel, Shelly B.
2016-01-01
Elucidating the neurobiological mechanisms underlying individual differences in the extent to which reward cues acquire the ability to act as incentive stimuli may contribute to the development of successful treatments for addiction and related disorders. We used the sign-tracker/goal-tracker animal model to examine the role of dopamine D2 and D3 receptors in the propensity to attribute incentive salience to reward cues. Following Pavlovian training, wherein a discrete lever-cue was paired with food reward, rats were classified as sign- or goal-trackers based on the resultant conditioned response. We examined the effects of D2/D3 agonists, 7-OH-DPAT (0.01–0.32 mg/kg) or pramipexole (0.032–0.32 mg/kg), the D2/D3 antagonist raclopride (0.1 mg/kg), and the selective D3 antagonist, SB-277011A (6 or 24 mg/kg), on the expression of sign- and goal-tracking conditioned responses. The lever-cue acquired predictive value and elicited a conditioned response for sign- and goal-trackers, but only for sign-trackers did it also acquire incentive value. Following administration of either 7-OH-DPAT, pramipexole, or raclopride, the performance of the previously acquired conditioned response was attenuated for both sign- and goal-trackers. For sign-trackers, the D2/D3 agonist, 7-OH-DPAT, also attenuated the conditioned reinforcing properties of the lever-cue. The selective D3 antagonist did not affect either conditioned response. Alterations in D2/D3 receptor signaling, but not D3 signaling alone, transiently attenuate a previously acquired Pavlovian conditioned response, regardless of whether the response is a result of incentive motivational processes. These findings suggest activity at the dopamine D2 receptor is critical for a reward cue to maintain either its incentive or predictive qualities. PMID:26909847
Lee, Hoe C.; Yanting Chee, Derserri; Selander, Helena; Falkmer, Torbjorn
2012-01-01
Background Current methods of determining licence retainment or cancellation is through on-road driving tests. Previous research has shown that occupational therapists frequently assess drivers’ visual attention while sitting in the back seat on the opposite side of the driver. Since the eyes of the driver are not always visible, assessment by eye contact becomes problematic. Such procedural drawbacks may challenge validity and reliability of the visual attention assessments. In terms of correctly classified attention, the aim of the study was to establish the accuracy and the inter-rater reliability of driving assessments of visual attention from the back seat. Furthermore, by establishing eye contact between the assessor and the driver through an additional mirror on the wind screen, the present study aimed to establish how much such an intervention would enhance the accuracy of the visual attention assessment. Methods Two drivers with Parkinson's disease (PD) and six control drivers drove a fixed route in a driving simulator while wearing a head mounted eye tracker. The eye tracker data showed where the foveal visual attention actually was directed. These data were time stamped and compared with the simultaneous manual scoring of the visual attention of the drivers. In four of the drivers, one with Parkinson's disease, a mirror on the windscreen was set up to arrange for eye contact between the driver and the assessor. Inter-rater reliability was performed with one of the Parkinson drivers driving, but without the mirror. Results Without mirror, the overall accuracy was 56% when assessing the three control drivers and with mirror 83%. However, for the PD driver without mirror the accuracy was 94%, whereas for the PD driver with a mirror the accuracy was 90%. With respect to the inter-rater reliability, a 73% agreement was found. Conclusion If the final outcome of a driving assessment is dependent on the subcategory of a protocol assessing visual attention, we suggest the use of an additional mirror to establish eye contact between the assessor and the driver. The clinicians’ observations on-road should not be a standalone assessment in driving assessments. Instead, eye trackers should be employed for further analyses and correlation in cases where there is doubt about a driver's attention. PMID:22461850
Kappa and Hirschberg ratio measured with an automated video gaze tracker.
Schaeffel, Frank
2002-05-01
To develop a fast automated procedure to measure kappa and the Hirschberg ratio for immediate use in a video gaze tracker. Using the hardware platform of the PowerRefractor and a 200 mm lens, the pupil was imaged with a resolution of 57 pixels/mm, at a camera distance of 90 cm. Both the positions of the first Purkinje image and the edges of the pupil were located at 25 Hz sampling rate with subpixel resolution using video image processing software developed under Borland C++. Subjects fixated on a red spot on the left side of the monitor. If their fixation was stable (standard deviation <0.2 degrees in 25 subsequent measurements evaluated in 1 s), the fixation spot appeared automatically on the right side, and the procedure was repeated. Data on the angular position of the optical axis for both targets were stored and provided kappa and the Hirschberg ratio with a standard deviation of about 0.2 degrees or better. This enabled the system to track fixation with a resolution of about 0.2 degrees. (1) Kappa was +3.91+/-2.73 degrees (right eyes), -3.93+/-2.68 degrees (left eyes, mean +/- SD from 24 young adults). Kappa was highly correlated in both eyes (r = 0.8996), but there were significant asymmetries between both eyes in three subjects (delta up to 3 degrees). (2) The Hirschberg ratios were 12.93+/-1.23 degrees/mm = 22.56 delta/mm (right eyes) and 12.82+/-1.49 degrees/mm = 22.38 delta/mm (left eyes). They were also highly correlated in both eyes (r = 0.931). (3) Neither kappa nor the Hirschberg ratios were correlated to refractive errors (range +0.50 to -7.75 D, mean -1.73+/-2.29 D [spherical equivalents]). (1) The video gaze tracker measured fixation with an angular resolution high enough to display the eye position during reading of individual words on the computer screen. (2) The applicable Hirschberg ratio changed with the power of the spectacles of the subjects by about 3% per diopter. (3) In some subjects, there were significant differences in the geometry of both eyeballs, which may be important in the analysis of strabismus. (4) Consistent with the assumption of retinal stretching, the linear distance of the fovea from the optical axis appeared to increase in myopia.
Swarm- Validation of Star Tracker and Accelerometer Data
NASA Astrophysics Data System (ADS)
Schack, Peter; Schlicht, Anja; Pail, Roland; Gruber, Thomas
2016-08-01
The ESA Swarm mission is designed to advance studies in the field of magnetosphere, thermosphere and gravity field. To be fortunate on this task precise knowledge of the orientation of the Swarm satellites is required together with knowledge about external forces acting on the satellites. The key sensors providing this information are the star trackers and the accelerometers. Based on star tracker studies conducted by the Denmark Technical University (DTU), we found interesting patterns in the interboresight angles on all three satellites, which are partly induced by temperature alterations. Additionally, structures of horizontal stripes seem to be caused by the unique distribution of observed stars on the charge-coupled device of the star trackers. Our accelerometer analyses focus on spikes and pulses in the observations. Those short term events on Swarm might originate from electrical processes introduced by sunlight illuminating the nadir foil. Comparisons to GOCE and GRACE are included.
Compressed normalized block difference for object tracking
NASA Astrophysics Data System (ADS)
Gao, Yun; Zhang, Dengzhuo; Cai, Donglan; Zhou, Hao; Lan, Ge
2018-04-01
Feature extraction is very important for robust and real-time tracking. Compressive sensing provided a technical support for real-time feature extraction. However, all existing compressive tracking were based on compressed Haar-like feature, and how to compress many more excellent high-dimensional features is worth researching. In this paper, a novel compressed normalized block difference feature (CNBD) was proposed. For resisting noise effectively in a highdimensional normalized pixel difference feature (NPD), a normalized block difference feature extends two pixels in the original formula of NPD to two blocks. A CNBD feature can be obtained by compressing a normalized block difference feature based on compressive sensing theory, with the sparse random Gaussian matrix as the measurement matrix. The comparative experiments of 7 trackers on 20 challenging sequences showed that the tracker based on CNBD feature can perform better than other trackers, especially than FCT tracker based on compressed Haar-like feature, in terms of AUC, SR and Precision.
Combined Feature Based and Shape Based Visual Tracker for Robot Navigation
NASA Technical Reports Server (NTRS)
Deans, J.; Kunz, C.; Sargent, R.; Park, E.; Pedersen, L.
2005-01-01
We have developed a combined feature based and shape based visual tracking system designed to enable a planetary rover to visually track and servo to specific points chosen by a user with centimeter precision. The feature based tracker uses invariant feature detection and matching across a stereo pair, as well as matching pairs before and after robot movement in order to compute an incremental 6-DOF motion at each tracker update. This tracking method is subject to drift over time, which can be compensated by the shape based method. The shape based tracking method consists of 3D model registration, which recovers 6-DOF motion given sufficient shape and proper initialization. By integrating complementary algorithms, the combined tracker leverages the efficiency and robustness of feature based methods with the precision and accuracy of model registration. In this paper, we present the algorithms and their integration into a combined visual tracking system.
Miniaturized star tracker for micro spacecraft with high angular rate
NASA Astrophysics Data System (ADS)
Li, Jianhua; Li, Zhifeng; Niu, Zhenhong; Liu, Jiaqi
2017-10-01
There is a clear need for miniaturized, lightweight, accurate and inexpensive star tracker for spacecraft with large anglar rate. To face these new constraints, the Beijing Institute of Space Long March Vehicle has designed, built and flown a low cost miniaturized star tracker that provides autonomous ("Lost in Space") inertial attitude determination, 2 Hz 3-axis star tracking, and digital imaging with embedded compression. Detector with high sensitivity is adopted to meet the dynamic and miniature requirement. A Sun and Moon avoiding method based on the calculation of Sun and Moon's vector by astronomical theory is proposed. The produced prototype weight 0.84kg, and can be used for a spacecraft with 6°/s anglar rate. The average angle measure error is less than 43 arc second. The ground verification and application of the star tracker during the pick-up flight test showed that the capability of the product meet the requirement.
Ma, Huilian; Jin, Jing; Li, Yun; Chen, Jiping
2017-10-08
A method of comprehensive screening of the target and non-target volatile organic compounds (VOCs) in industrial exhaust gas using thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) has been developed. In this paper, two types of solid phase adsorption column were compared, and the Tenex SS TD Tube was selected. The analytes were enriched into the adsorption tube by constant flow sampling, and detected by TD-GC-MS in full scan mode. Target compounds were quantified by internal standard method, and the quantities of non-target compounds were calculated by response coefficient of toluene. The method detection limits (MDLs) for the 24 VOCs were 1.06 to 5.44 ng, and MDLs could also be expressed as 0.004 to 0.018 mg/m 3 assuming that the sampling volume was 300 mL. The average recoveries were in the range of 78.4% to 89.4% with the relative standard deviations (RSDs) of 3.9% to 14.4% ( n =7). The established analytical method was applied for the comprehensive screening of VOCs in a waste incineration power plant in Dalian city. Twenty-nine VOCs were identified. In these compounds, only five VOCs were the target compounds set in advance, which accounted for 26.7% of the total VOCs identified. Therefore, this study further proved the importance of screening non-target compounds in the analysis of VOCs in industrial exhaust gas, and has certain reference significance for the complete determination of VOCs distribution.
MSFC Skylab contamination control systems mission evaluation
NASA Technical Reports Server (NTRS)
1974-01-01
Cluster external contamination control evaluation was made throughout the Skylab Mission. This evaluation indicated that contamination control measures instigated during the design, development, and operational phases of this program were adequate to reduce the general contamination environment external to the Cluster below the threshold senstivity levels for experiments and affected subsystems. Launch and orbit contamination control features included eliminating certain vents, rerouting vents for minimum contamination impact, establishing filters, incorporating materials with minimum outgassing characteristics and developing operational constraints and mission rules to minimize contamination effects. Prior to the launch of Skylab, contamination control math models were developed which were used to predict Cluster surface deposition and background brightness levels throughout the mission. The report summarizes the Skylab system and experiment contamination control evaluation. The Cluster systems and experiments evaluated include Induced Atmosphere, Corollary and ATM Experiments, Thermal Control Surfaces, Solar Array Systems, Windows and Star Tracker.
NASA Astrophysics Data System (ADS)
Kharlamov, Petr; Dementev, Dmitrii; Shitenkov, Mikhail
2017-10-01
High-energy heavy-ion collision experiments provide the unique possibility to create and investigate extreme states of strongly-interacted matter and address the fundamental aspects of QCD. The experimental investigation the QCD phase diagram would be a major breakthrough in our understanding of the properties of nuclear matter. The reconstruction of the charged particles created in the nuclear collisions, including the determination of their momenta, is the central detection task in high-energy heavy-ion experiments. It is taken up by the Silicon Tracking System in CBM@FAIR and by Inner Tracker in MPD@NICA currently under development. These experiments requires very fast and radiation hard detectors, a novel data read-out and analysis concept including free streaming front-end electronics. Thermal and beam tests of prototype detector modules for these tracking systems showed the stability of sensors and readout electronics operation.
Thermally-Constrained Fuel-Optimal ISS Maneuvers
NASA Technical Reports Server (NTRS)
Bhatt, Sagar; Svecz, Andrew; Alaniz, Abran; Jang, Jiann-Woei; Nguyen, Louis; Spanos, Pol
2015-01-01
Optimal Propellant Maneuvers (OPMs) are now being used to rotate the International Space Station (ISS) and have saved hundreds of kilograms of propellant over the last two years. The savings are achieved by commanding the ISS to follow a pre-planned attitude trajectory optimized to take advantage of environmental torques. The trajectory is obtained by solving an optimal control problem. Prior to use on orbit, OPM trajectories are screened to ensure a static sun vector (SSV) does not occur during the maneuver. The SSV is an indicator that the ISS hardware temperatures may exceed thermal limits, causing damage to the components. In this paper, thermally-constrained fuel-optimal trajectories are presented that avoid an SSV and can be used throughout the year while still reducing propellant consumption significantly.
Kuhn, Brittany N; Klumpner, Marin S; Covelo, Ignacio R; Campus, Paolo; Flagel, Shelly B
2018-04-01
The paraventricular nucleus of the thalamus (PVT) has been shown to mediate cue-motivated behaviors, such as sign- and goal-tracking, as well as reinstatement of drug-seeking behavior. However, the role of the PVT in mediating individual variation in cue-induced drug-seeking behavior remains unknown. This study aimed to determine if inactivation of the PVT differentially mediates cue-induced drug-seeking behavior in sign-trackers and goal-trackers. Rats were characterized as sign-trackers (STs) or goal-trackers (GTs) based on their Pavlovian conditioned approach behavior. Rats were then exposed to 15 days of cocaine self-administration, followed by a 2-week forced abstinence period and then extinction training. Rats then underwent tests for cue-induced reinstatement and general locomotor activity, prior to which they received an infusion of either saline (control) or baclofen/muscimol (B/M) to inactivate the PVT. Relative to control animals of the same phenotype, GTs show a robust increase in cue-induced drug-seeking behavior following PVT inactivation, whereas the behavior of STs was not affected. PVT inactivation did not affect locomotor activity in either phenotype. In GTs, the PVT appears to inhibit the expression of drug-seeking, presumably by attenuating the incentive value of the drug cue. Thus, inactivation of the PVT releases this inhibition in GTs, resulting in an increase in cue-induced drug-seeking behavior. PVT inactivation did not affect cue-induced drug-seeking behavior in STs, suggesting that the role of the PVT in encoding the incentive motivational value of drug cues differs between STs and GTs.
El-Amrawy, Fatema
2015-01-01
Objectives The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Methods Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. Results The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. Conclusions The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure. PMID:26618039
El-Amrawy, Fatema; Nounou, Mohamed Ismail
2015-10-01
The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure.
Into the deep: Evaluation of SourceTracker for assessment of faecal contamination of coastal waters.
Henry, Rebekah; Schang, Christelle; Coutts, Scott; Kolotelo, Peter; Prosser, Toby; Crosbie, Nick; Grant, Trish; Cottam, Darren; O'Brien, Peter; Deletic, Ana; McCarthy, David
2016-04-15
Faecal contamination of recreational waters is an increasing global health concern. Tracing the source of the contaminant is a vital step towards mitigation and disease prevention. Total 16S rRNA amplicon data for a specific environment (faeces, water, soil) and computational tools such as the Markov-Chain Monte Carlo based SourceTracker can be applied to microbial source tracking (MST) and attribution studies. The current study applied artificial and in-laboratory derived bacterial communities to define the potential and limitations associated with the use of SourceTracker, prior to its application for faecal source tracking at three recreational beaches near Port Phillip Bay (Victoria, Australia). The results demonstrated that at minimum multiple model runs of the SourceTracker modelling tool (i.e. technical replicates) were required to identify potential false positive predictions. The calculation of relative standard deviations (RSDs) for each attributed source improved overall predictive confidence in the results. In general, default parameter settings provided high sensitivity, specificity, accuracy and precision. Application of SourceTracker to recreational beach samples identified treated effluent as major source of human-derived faecal contamination, present in 69% of samples. Site-specific sources, such as raw sewage, stormwater and bacterial populations associated with the Yarra River estuary were also identified. Rainfall and associated sand resuspension at each location correlated with observed human faecal indicators. The results of the optimised SourceTracker analysis suggests that local sources of contamination have the greatest effect on recreational coastal water quality. Copyright © 2016 Elsevier Ltd. All rights reserved.
Computational design and experimental validation of new thermal barrier systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Shengmin
2015-03-31
The focus of this project is on the development of a reliable and efficient ab initio based computational high temperature material design method which can be used to assist the Thermal Barrier Coating (TBC) bond-coat and top-coat design. Experimental evaluations on the new TBCs are conducted to confirm the new TBCs’ properties. Southern University is the subcontractor on this project with a focus on the computational simulation method development. We have performed ab initio density functional theory (DFT) method and molecular dynamics simulation on screening the top coats and bond coats for gas turbine thermal barrier coating design and validationmore » applications. For experimental validations, our focus is on the hot corrosion performance of different TBC systems. For example, for one of the top coatings studied, we examined the thermal stability of TaZr 2.75O 8 and confirmed it’s hot corrosion performance.« less
Optimization of Norbornadiene Compounds for Solar Thermal Storage by First-Principles Calculations.
Kuisma, Mikael; Lundin, Angelica; Moth-Poulsen, Kasper; Hyldgaard, Per; Erhart, Paul
2016-07-21
Molecular photoswitches capable of storing solar energy are interesting candidates for future renewable energy applications. Here, using quantum mechanical calculations, we carry out a systematic screening of crucial optical (solar spectrum match) and thermal (storage energy density) properties of 64 such compounds based on the norbornadiene-quadricyclane system. Whereas a substantial number of these molecules reach the theoretical maximum solar power conversion efficiency, this requires a strong red-shift of the absorption spectrum, which causes undesirable absorption by the photoisomer as well as reduced thermal stability. These compounds typically also have a large molecular mass, leading to low storage densities. By contrast, single-substituted systems achieve a good compromise between efficiency and storage density, while avoiding competing absorption by the photo-isomer. This establishes guiding principles for the future development of molecular solar thermal storage systems. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development of infrared thermal imager for dry eye diagnosis
NASA Astrophysics Data System (ADS)
Chiang, Huihua Kenny; Chen, Chih Yen; Cheng, Hung You; Chen, Ko-Hua; Chang, David O.
2006-08-01
This study aims at the development of non-contact dry eye diagnosis based on an infrared thermal imager system, which was used to measure the cooling of the ocular surface temperature of normal and dry eye patients. A total of 108 subjects were measured, including 26 normal and 82 dry eye patients. We have observed that the dry eye patients have a fast cooling of the ocular surface temperature than the normal control group. We have developed a simplified algorithm for calculating the temperature decay constant of the ocular surface for discriminating between normal and dry eye. This study shows the diagnostic of dry eye syndrome by the infrared thermal imager system has reached a sensitivity of 79.3%, a specificity of 75%, and the area under the ROC curve 0.841. The infrared thermal imager system has a great potential to be developed for dry eye screening with the advantages of non-contact, fast, and convenient implementation.
NASA Technical Reports Server (NTRS)
Valentine, Peter G.; Lawrence, Timothy W.; Gubert, Michael K.; Milos, Frank S.; Kiser, James D.; Ohlhorst, Craig W.; Koenig, John R.
2006-01-01
As a collaborative effort among NASA Centers, the "Lightweight Nonmetallic Thermal Protection Materials Technology" Project was set up to assist mission/vehicle design trade studies, to support risk reduction in thermal protection system (TPS) material selections, to facilitate vehicle mass optimization, and to aid development of human-rated TPS qualification and certification plans. Missions performing aerocapture, aerobraking, or direct aeroentry rely on advanced heatshields that allow reductions in spacecraft mass by minimizing propellant requirements. Information will be presented on candidate materials for such reentry approaches and on screening tests conducted (material property and space environmental effects tests) to evaluate viable candidates. Seventeen materials, in three classes (ablatives, tiles, and ceramic matrix composites), were studied. In additional to physical, mechanical, and thermal property tests, high heat flux laser tests and simulated-reentry oxidation tests were performed. Space environmental effects testing, which included exposures to electrons, atomic oxygen, and hypervelocity impacts, was also conducted.
Tripi, Jordan A; Dent, Micheal L; Meyer, Paul J
2017-02-01
Individuals prone to attribute incentive salience to food-associated stimuli ("cues") are also more sensitive to cues during drug seeking and drug taking. This may be due in part to a difference in sensitivity to the affective or other stimulus properties of the drug. In rats, these properties are associated with 50-kHz ultrasonic vocalizations (USVs), in that they are elicited during putative positive affective and motivational states, including in response to drugs of abuse. We sought to determine whether individual differences in the tendency to attribute incentive salience to a food cue (as measured by approach) were associated with differences in cocaine-induced USVs. We also tested whether the food cue would elicit USVs and if this response was related to approach to the food cue. In experiment 1, rats underwent Pavlovian conditioned approach (PavCA) training where they learned to associate a cue (an illuminated lever) with the delivery of a food pellet into a food cup. Subjects were categorized based on their approach to the cue ("sign-trackers") or to the food cup ("goal-trackers"). Rats subsequently underwent nine testing days in which they were given saline or cocaine (10 mg/kg i.p) and placed into a locomotor chamber. In experiment 2, rats were first tested in the locomotor chambers for one saline-treated day followed by one cocaine-treated day and then trained in PavCA. USVs were recorded from a subset of individuals during the last day of PavCA to determine if the food cue would elicit USVs. Sign-trackers produced 5-24 times more cocaine-induced 50 kHz USVs compared to goal-trackers for all days of experiment 1, and this response sensitized with repeated cocaine, only in sign-trackers. Similarly in experiment 2, individuals that produced the most cocaine-induced USVs on a single exposure also showed the greatest tendency to sign-track during PavCA. Lastly, while sign-trackers produced more USVs during PavCA generally, the cue itself did not elicit additional USVs in sign- or goal-trackers. These results indicate a robust and consistent relationship between approach to a food cue and cocaine-induced USV production. Thus, these USVs may index the neurobiological differences underlying the behavioral distinctions of sign- and goal-trackers.
Training Surgical Residents With a Haptic Robotic Central Venous Catheterization Simulator.
Pepley, David F; Gordon, Adam B; Yovanoff, Mary A; Mirkin, Katelin A; Miller, Scarlett R; Han, David C; Moore, Jason Z
Ultrasound guided central venous catheterization (CVC) is a common surgical procedure with complication rates ranging from 5 to 21 percent. Training is typically performed using manikins that do not simulate anatomical variations such as obesity and abnormal vessel positioning. The goal of this study was to develop and validate the effectiveness of a new virtual reality and force haptic based simulation platform for CVC of the right internal jugular vein. A CVC simulation platform was developed using a haptic robotic arm, 3D position tracker, and computer visualization. The haptic robotic arm simulated needle insertion force that was based on cadaver experiments. The 3D position tracker was used as a mock ultrasound device with realistic visualization on a computer screen. Upon completion of a practice simulation, performance feedback is given to the user through a graphical user interface including scoring factors based on good CVC practice. The effectiveness of the system was evaluated by training 13 first year surgical residents using the virtual reality haptic based training system over a 3 month period. The participants' performance increased from 52% to 96% on the baseline training scenario, approaching the average score of an expert surgeon: 98%. This also resulted in improvement in positive CVC practices including a 61% decrease between final needle tip position and vein center, a decrease in mean insertion attempts from 1.92 to 1.23, and a 12% increase in time spent aspirating the syringe throughout the procedure. A virtual reality haptic robotic simulator for CVC was successfully developed. Surgical residents training on the simulation improved to near expert levels after three robotic training sessions. This suggests that this system could act as an effective training device for CVC. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Björnsdotter, Maria K; Jonker, Willem; Legradi, Jessica; Kool, Jeroen; Ballesteros-Gómez, Ana
2017-12-01
Thermal paper contains potentially toxic additives, such as bisphenol A (BPA), as a common color developer. Because of its known endocrine disrupting effects, structural analogues to BPA, such as bisphenol S (BPS), D-8 and Pergafast 201, have been used as alternatives, but little is known about the presence and toxicological effects of alternatives other than BPS. In this study, thermal paper is screened by direct probe ambient mass spectrometry (rapid pre-screening method not requiring sample preparation) and by liquid chromatography (LC) with high resolution time-of flight (TOF-MS) mass spectrometry. Cash receipts and other thermal paper products (cinema tickets, boarding passes and luggage tags) were analyzed. Besides BPA and BPS, other developers only recently reported (Pergafast 201, D-8) or to the best of our knowledge not reported before (D-90, TGSA, BPS-MAE) were frequently found as well as some related unreported impurities (2,4-BPS that is a BPS related impurity and a TGSA related impurity). To gain some insight into the potential estrogenicity of the detected developers, a selection of extracts was further analyzed using a LC-nanofractionation platform in combination with cell-based bioassay testing. These preliminary results seems to indicate very low or absence of estrogenic activity for Pergafast 201, D-8, D-90, TGSA and BPS-MAE in comparison to BPA and BPS, although further dose-response tests with authentic standards are required to confirm these results. Compounds for which standards were available were also tested for developmental toxicity and neurotoxicity using zebrafish (Danio rerio) embryos. TGSA and D-8 induced similar teratogenic effects as BPA in zebrafish embryos. BPS and 2,4-BPS did not induce any developmental effects but 2,4-BPS did alter the locomotor activity at the tested concentration. Our findings suggest that the alternatives used as alternatives to BPA (except BPS) might not be estrogenic. However, TGSA and D-8 showed abnormal developmental effects similar to BPA. Copyright © 2017 Elsevier B.V. All rights reserved.
Shima, Jun; Ando, Akira; Takagi, Hiroshi
2008-03-01
Yeasts used in bread making are exposed to air-drying stress during dried yeast production processes. To clarify the genes required for air-drying tolerance, we performed genome-wide screening using the complete deletion strain collection of diploid Saccharomyces cerevisiae. The screening identified 278 gene deletions responsible for air-drying sensitivity. These genes were classified based on their cellular function and on the localization of their gene products. The results showed that the genes required for air-drying tolerance were frequently involved in mitochondrial functions and in connection with vacuolar H(+)-ATPase, which plays a role in vacuolar acidification. To determine the role of vacuolar acidification in air-drying stress tolerance, we monitored intracellular pH. The results showed that intracellular acidification was induced during air-drying and that this acidification was amplified in a deletion mutant of the VMA2 gene encoding a component of vacuolar H(+)-ATPase, suggesting that vacuolar H(+)-ATPase helps maintain intracellular pH homeostasis, which is affected by air-drying stress. To determine the effects of air-drying stress on mitochondria, we analysed the mitochondrial membrane potential under air-drying stress conditions using MitoTracker. The results showed that mitochondria were extremely sensitive to air-drying stress, suggesting that a mitochondrial function is required for tolerance to air-drying stress. We also analysed the correlation between oxidative-stress sensitivity and air-drying-stress sensitivity. The results suggested that oxidative stress is a critical determinant of sensitivity to air-drying stress, although ROS-scavenging systems are not necessary for air-drying stress tolerance. (c) 2008 John Wiley & Sons, Ltd.
Screen printing technology applied to silicon solar cell fabrication
NASA Technical Reports Server (NTRS)
Thornhill, J. W.; Sipperly, W. E.
1980-01-01
The process for producing space qualified solar cells in both the conventional and wraparound configuration using screen printing techniques was investigated. Process modifications were chosen that could be easily automated or mechanized. Work was accomplished to optimize the tradeoffs associated with gridline spacing, gridline definition and junction depth. An extensive search for possible front contact metallization was completed. The back surface field structures along with the screen printed back contacts were optimized to produce open circuit voltages of at least an average of 600 millivolts. After all intended modifications on the process sequence were accomplished, the cells were exhaustively tested. Electrical tests at AMO and 28 C were made before and after boiling water immersion, thermal shock, and storage under conditions of high temperature and high humidity.
NASA Technical Reports Server (NTRS)
Thornhill, J. W.
1977-01-01
The development of a process for fabricating 2 x 4 cm back surface field silicon solar cells having screen printed wraparound contacts is described. This process was specifically designed to be amenable for incorporation into the automated nonvacuum production line. Techniques were developed to permit the use of screen printing for producing improved back surface field structures, wraparound dielectric layers, and wraparound contacts. The optimized process sequence was then used to produce 1852 finished cells. Tests indicated an average conversion efficiency of 11% at AMO and 28 C, with an average degradation of maximum power output of 1.5% after boiling water immersion or thermal shock cycling. Contact adherence was satisfactory after these tests, as well as long term storage at high temperature and high humidity.
Remote control radioactive-waste removal system uses modulated laser transmitter
NASA Technical Reports Server (NTRS)
Burcher, E. E.; Kopia, L. P.; Rowland, C. W.; Sinclair, A. R.
1971-01-01
Laser remote control system consists of transmitter, auto tracker, and receiver. Transmitter and tracker, packaged together and bore sighted, constitute control station, receiver is slave station. Model has five command channels and optical link operating range of 110 m.
Design of the forward straw tube tracker for the PANDA experiment
NASA Astrophysics Data System (ADS)
Smyrski, J.; Apostolou, A.; Biernat, J.; Czyżycki, W.; Filo, G.; Fioravanti, E.; Fiutowski, T.; Gianotti, P.; Idzik, M.; Korcyl, G.; Korcyl, K.; Lisowski, E.; Lisowski, F.; Płażek, J.; Przyborowski, D.; Przygoda, W.; Ritman, J.; Salabura, P.; Savrie, M.; Strzempek, P.; Swientek, K.; Wintz, P.; Wrońska, A.
2017-06-01
The design of the Forward Tracker for the Forward Spectrometer of the PANDA experiment is described. The tracker consists of 6 tracking stations, each comprising 4 planar double layers of straw tube detectors, and has a total material budget of only 2% X0. The straws are made self-supporting by a 1 bar over-pressure of the working gas mixture (Ar/CO2). This allows to use lightweight and compact rectangular support frames for the double layers and to split the frames into pairs of C-shaped half-frames for an easier installation on the beam line.
Enhanced online convolutional neural networks for object tracking
NASA Astrophysics Data System (ADS)
Zhang, Dengzhuo; Gao, Yun; Zhou, Hao; Li, Tianwen
2018-04-01
In recent several years, object tracking based on convolution neural network has gained more and more attention. The initialization and update of convolution filters can directly affect the precision of object tracking effective. In this paper, a novel object tracking via an enhanced online convolution neural network without offline training is proposed, which initializes the convolution filters by a k-means++ algorithm and updates the filters by an error back-propagation. The comparative experiments of 7 trackers on 15 challenging sequences showed that our tracker can perform better than other trackers in terms of AUC and precision.
Electrical production testing of the D0 Silicon microstrip tracker detector modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
D0, SMT Production Testing Group; /Fermilab
The D0 Silicon Microstrip Tracker (SMT) is the innermost system of the D0 detector in Run 2. It consists of 912 detector units, corresponding to 5 different types of assemblies, which add up to a system with 792,576 readout channels. The task entrusted to the Production Testing group was to thoroughly debug, test and grade each detector module before its installation in the tracker. This note describes the production testing sequence and the procedures by which the detector modules were electrically tested and characterized at the various stages of their assembly.
A laser-based eye-tracking system.
Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J
2002-11-01
This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.
Design of a cost-effective laser spot tracker
NASA Astrophysics Data System (ADS)
Artan, Göktuǧ Gencehan; Sari, Hüseyin
2017-05-01
One of the most important aspects of guided systems is detection. The most convenient detection in the sense of precision can be achieved with a laser spot tracker. This study deals with a military grade, high performance and cost-effective laser spot tracker for a guided system. The aim is to develop a high field of view system that will detect a laser spot from a distance of 3 kilometers in which the target is designated from 3 kilometers with a laser. The study basically consists of the system design, modeling, producing and the conducting performance tests of the whole system.
Low-Frequency Error Extraction and Compensation for Attitude Measurements from STECE Star Tracker
Lai, Yuwang; Gu, Defeng; Liu, Junhong; Li, Wenping; Yi, Dongyun
2016-01-01
The low frequency errors (LFE) of star trackers are the most penalizing errors for high-accuracy satellite attitude determination. Two test star trackers- have been mounted on the Space Technology Experiment and Climate Exploration (STECE) satellite, a small satellite mission developed by China. To extract and compensate the LFE of the attitude measurements for the two test star trackers, a new approach, called Fourier analysis, combined with the Vondrak filter method (FAVF) is proposed in this paper. Firstly, the LFE of the two test star trackers’ attitude measurements are analyzed and extracted by the FAVF method. The remarkable orbital reproducibility features are found in both of the two test star trackers’ attitude measurements. Then, by using the reproducibility feature of the LFE, the two star trackers’ LFE patterns are estimated effectively. Finally, based on the actual LFE pattern results, this paper presents a new LFE compensation strategy. The validity and effectiveness of the proposed LFE compensation algorithm is demonstrated by the significant improvement in the consistency between the two test star trackers. The root mean square (RMS) of the relative Euler angle residuals are reduced from [27.95′′, 25.14′′, 82.43′′], 3σ to [16.12′′, 15.89′′, 53.27′′], 3σ. PMID:27754320
DOE Office of Scientific and Technical Information (OSTI.GOV)
Argo, P.E.; DeLapp, D.; Sutherland, C.D.
TRACKER is an extension of a three-dimensional Hamiltonian raytrace code developed some thirty years ago by R. Michael Jones. Subsequent modifications to this code, which is commonly called the {open_quotes}Jones Code,{close_quotes} were documented by Jones and Stephensen (1975). TRACKER incorporates an interactive user`s interface, modern differential equation integrators, graphical outputs, homing algorithms, and the Ionospheric Conductivity and Electron Density (ICED) ionosphere. TRACKER predicts the three-dimensional paths of radio waves through model ionospheres by numerically integrating Hamilton`s equations, which are a differential expression of Fermat`s principle of least time. By using continuous models, the Hamiltonian method avoids false caustics and discontinuousmore » raypath properties often encountered in other raytracing methods. In addition to computing the raypath, TRACKER also calculates the group path (or pulse travel time), the phase path, the geometrical (or {open_quotes}real{close_quotes}) pathlength, and the Doppler shift (if the time variation of the ionosphere is explicitly included). Computational speed can be traded for accuracy by specifying the maximum allowable integration error per step in the integration. Only geometrical optics are included in the main raytrace code; no partial reflections or diffraction effects are taken into account. In addition, TRACKER does not lend itself to statistical descriptions of propagation -- it requires a deterministic model of the ionosphere.« less
Popelka, Stanislav; Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka
2016-01-01
The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe.
Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka
2016-01-01
The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe. PMID:27087805
NASA Technical Reports Server (NTRS)
Lee, Michael
1995-01-01
Since the original post-launch calibration of the FHSTs (Fixed Head Star Trackers) on EUVE (Extreme Ultraviolet Explorer) and UARS (Upper Atmosphere Research Satellite), the Flight Dynamics task has continued to analyze the FHST performance. The algorithm used for inflight alignment of spacecraft sensors is described and the equations for the errors in the relative alignment for the simple 2 star tracker case are shown. Simulated data and real data are used to compute the covariance of the relative alignment errors. Several methods for correcting the alignment are compared and results analyzed. The specific problems seen on orbit with UARS and EUVE are then discussed. UARS has experienced anomalous tracker performance on an FHST resulting in continuous variation in apparent tracker alignment. On EUVE, the FHST residuals from the attitude determination algorithm showed a dependence on the direction of roll during survey mode. This dependence is traced back to time tagging errors and the original post launch alignment is found to be in error due to the impact of the time tagging errors on the alignment algorithm. The methods used by the FDF (Flight Dynamics Facility) to correct for these problems is described.
Could we do better? Behavioural tracking on recommended consumer health websites.
Burkell, Jacquelyn; Fortier, Alexandre
2015-09-01
This study examines behavioural tracking practices on consumer health websites, contrasting tracking on sites recommended by information professionals with tracking on sites returned by Google. Two lists of consumer health websites were constructed: sites recommended by information professionals and sites returned by Google searches. Sites were divided into three groups according to source (Recommended-Only, Google-Only or both) and type (Government, Not-for-Profit or Commercial). Behavioural tracking practices on each website were documented using a protocol that detected cookies, Web beacons and Flash cookies. The presence and the number of trackers that collect personal information were contrasted across source and type of site; a second set of analyses specifically examined Advertising trackers. Recommended-Only sites show lower levels of tracking - especially tracking by advertisers - than do Google-Only sites or sites found through both sources. Government and Not-for-Profit sites have fewer trackers, particularly from advertisers, than do Commercial sites. Recommended sites, especially those from Government or Not-for-Profit organisations, present a lower privacy threat than sites returned by Google searches. Nonetheless, most recommended websites include some trackers, and half include at least one Advertising tracker. To protect patron privacy, information professionals should examine the tracking practices of the websites they recommend. © 2015 Health Libraries Group.
NASA Astrophysics Data System (ADS)
Riegel, C.; Backhaus, M.; Van Hoorne, J. W.; Kugathasan, T.; Musa, L.; Pernegger, H.; Riedler, P.; Schaefer, D.; Snoeys, W.; Wagner, W.
2017-01-01
A part of the upcoming HL-LHC upgrade of the ATLAS Detector is the construction of a new Inner Tracker. This upgrade opens new possibilities, but also presents challenges in terms of occupancy and radiation tolerance. For the pixel detector inside the inner tracker, hybrid modules containing passive silicon sensors and connected readout chips are presently used, but require expensive assembly techniques like fine-pitch bump bonding. Silicon devices fabricated in standard commercial CMOS technologies, which include part or all of the readout chain, are also investigated offering a reduced cost as they are cheaper per unit area than traditional silicon detectors. If they contain the full readout chain, as for a fully monolithic approach, there is no need for the expensive flip-chip assembly, resulting in a further cost reduction and material savings. In the outer pixel layers of the ATLAS Inner Tracker, the pixel sensors must withstand non-ionising energy losses of up to 1015 n/cm2 and offer a timing resolution of 25 ns or less. This paper presents test results obtained on a monolithic test chip, the TowerJazz 180nm Investigator, towards these specifications. The presented program of radiation hardness and timing studies has been launched to investigate this technology's potential for the new ATLAS Inner Tracker.
Kim, Youngdeok; Lumpkin, Angela; Lochbaum, Marc; Stegemeier, Steven; Kitten, Karla
2018-08-01
This study examined the effects of utilizing a wearable activity tracker in a credit-based physical activity instructional program (PAIP) for promoting physical activity (PA) in college students. Fourteen PAIP courses in a large public university were randomly assigned into intervention (k = 7; n = 101) and control (k = 7; n = 86) groups. All courses focused on a core curriculum that covers basic exercise and behavioral science contents through lectures and activity sessions. A Misfit Flash activity tracker was provided to students in the intervention group. Objective PA assessments occurred at baseline, mid-, and end-of-semester during a 15-week academic semester. The control group showed a significant reduction in moderate- and vigorous-intensity PA (MVPA) minutes from baseline to the end-of-semester (P <.05), whereas the intervention group showed no changes in MVPA minutes over time. However, the intervention group also showed increased sedentary time and decreased time spent in light-intensity PA during the intervention period. Taken together, the present study found null effects of utilizing the wearable activity tracker in promoting PA in college students suggesting that intervention of primary using the wearable activity tracker as a behavior change strategy may not be effective to increase in PA in this setting.
Tsai, Jason Sheng-Hong; Du, Yan-Yi; Huang, Pei-Hsiang; Guo, Shu-Mei; Shieh, Leang-San; Chen, Yuhua
2011-07-01
In this paper, a digital redesign methodology of the iterative learning-based decentralized adaptive tracker is proposed to improve the dynamic performance of sampled-data linear large-scale control systems consisting of N interconnected multi-input multi-output subsystems, so that the system output will follow any trajectory which may not be presented by the analytic reference model initially. To overcome the interference of each sub-system and simplify the controller design, the proposed model reference decentralized adaptive control scheme constructs a decoupled well-designed reference model first. Then, according to the well-designed model, this paper develops a digital decentralized adaptive tracker based on the optimal analog control and prediction-based digital redesign technique for the sampled-data large-scale coupling system. In order to enhance the tracking performance of the digital tracker at specified sampling instants, we apply the iterative learning control (ILC) to train the control input via continual learning. As a result, the proposed iterative learning-based decentralized adaptive tracker not only has robust closed-loop decoupled property but also possesses good tracking performance at both transient and steady state. Besides, evolutionary programming is applied to search for a good learning gain to speed up the learning process of ILC. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
Participatory Sensing Marine Debris: Current Trends and Future Opportunities
NASA Astrophysics Data System (ADS)
Jambeck, J.; Johnsen, K.
2016-02-01
The monitoring of litter and debris is challenging at the global scale because of spatial and temporal variability, disconnected local organizations and the use of paper and pen for documentation. The Marine Debris Tracker mobile app and citizen science program allows for the collection of global standardized data at a scale, speed and efficiency that was not previously possible. The app itself also serves as an outreach and education tool, creating an engaged participatory sensing instrument. This instrument is characterized by several aspects including range and frequency, accuracy and precision, accessibility, measurement dimensions, participant performance, and statistical analysis. Also, important to Marine Debris Tracker is open data and transparency. A web portal provides data that users have logged allowing immediate feedback to users and additional education opportunities. The engagement of users through a top tracker competition and social media keeps participants interested in the Marine Debris Tracker community. Over half a million items have been tracked globally, and maps provide both global and local distribution of data. The Marine Debris Tracker community and dataset continues to grow daily. We will present current usage and engagement, participatory sensing data distributions, choropleth maps of areas of active tracking, and discuss future technologies and platforms to expand data collection and conduct statistical analysis.
Sloan, Robert A; Kim, Youngdeok; Sahasranaman, Aarti; Müller-Riemenschneider, Falk; Biddle, Stuart J H; Finkelstein, Eric A
2018-03-22
A recent meta-analysis surmised pedometers were a useful panacea to independently reduce sedentary time (ST). To further test and expand on this deduction, we analyzed the ability of a consumer-wearable activity tracker to reduce ST and prolonged sedentary bouts (PSB). We originally conducted a 12-month randomized control trial where 800 employees from 13 organizations were assigned to control, activity tracker, or one of two activity tracker plus incentive groups designed to increase step count. The primary outcome was accelerometer measured moderate-to-vigorous physical activity. We conducted a secondary analysis on accelerometer measured daily ST and PSB bouts. A general linear mixed model was used to examine changes in ST and prolonged sedentary bouts, followed by between-group pairwise comparisons. Regression analyses were conducted to examine the association of changes in step counts with ST and PSB. The changes in ST and PSB were not statistically significant and not different between the groups (P < 0.05). Increases in step counts were concomitantly associated with decreases in ST and PSB, regardless of intervention (P < 0.05). Caution should be taken when considering consumer-wearable activity trackers as a means to reduce sedentary behavior. Trial registration NCT01855776 Registered: August 8, 2012.
Brakenridge, C L; Fjeldsoe, B S; Young, D C; Winkler, E A H; Dunstan, D W; Straker, L M; Healy, G N
2016-11-04
Office workers engage in high levels of sitting time. Effective, context-specific, and scalable strategies are needed to support widespread sitting reduction. This study aimed to evaluate organisational-support strategies alone or in combination with an activity tracker to reduce sitting in office workers. From one organisation, 153 desk-based office workers were cluster-randomised (by team) to organisational support only (e.g., manager support, emails; 'Group ORG', 9 teams, 87 participants), or organisational support plus LUMOback activity tracker ('Group ORG + Tracker', 9 teams, 66 participants). The waist-worn tracker provided real-time feedback and prompts on sitting and posture. ActivPAL3 monitors were used to ascertain primary outcomes (sitting time during work- and overall hours) and other activity outcomes: prolonged sitting time (≥30 min bouts), time between sitting bouts, standing time, stepping time, and number of steps. Health and work outcomes were assessed by questionnaire. Changes within each group (three- and 12 months) and differences between groups were analysed by linear mixed models. Missing data were multiply imputed. At baseline, participants (46 % women, 23-58 years) spent (mean ± SD) 74.3 ± 9.7 % of their workday sitting, 17.5 ± 8.3 % standing and 8.1 ± 2.7 % stepping. Significant (p < 0.05) reductions in sitting time (both work and overall) were observed within both groups, but only at 12 months. For secondary activity outcomes, Group ORG significantly improved in work prolonged sitting, time between sitting bouts and standing time, and overall prolonged sitting time (12 months), and in overall standing time (three- and 12 months); while Group ORG + Tracker, significantly improved in work prolonged sitting, standing, stepping and overall standing time (12 months). Adjusted for confounders, the only significant between-group differences were a greater stepping time and step count for Group ORG + Tracker relative to Group ORG (+20.6 min/16 h day, 95 % CI: 3.1, 38.1, p = 0.021; +846.5steps/16 h day, 95 % CI: 67.8, 1625.2, p = 0.033) at 12 months. Observed changes in health and work outcomes were small and not statistically significant. Organisational-support strategies with or without an activity tracker resulted in improvements in sitting, prolonged sitting and standing; adding a tracker enhanced stepping changes. Improvements were most evident at 12 months, suggesting the organisational-support strategies may have taken time to embed within the organisation. Australian New Zealand Clinical Trial Registry: ACTRN12614000252617 . Registered 10 March 2014.
Borysko, Petro; Moroz, Yurii S; Vasylchenko, Oleksandr V; Hurmach, Vasyl V; Starodubtseva, Anastasia; Stefanishena, Natalia; Nesteruk, Kateryna; Zozulya, Sergey; Kondratov, Ivan S; Grygorenko, Oleksandr O
2018-05-09
A combination approach of a fragment screening and "SAR by catalog" was used for the discovery of bromodomain-containing protein 4 (BRD4) inhibitors. Initial screening of 3695-fragment library against bromodomain 1 of BRD4 using thermal shift assay (TSA), followed by initial hit validation, resulted in 73 fragment hits, which were used to construct a follow-up library selected from available screening collection. Additionally, analogs of inactive fragments, as well as a set of randomly selected compounds were also prepared (3 × 3200 compounds in total). Screening of the resulting sets using TSA, followed by re-testing at several concentrations, counter-screen, and TR-FRET assay resulted in 18 confirmed hits. Compounds derived from the initial fragment set showed better hit rate as compared to the other two sets. Finally, building dose-response curves revealed three compounds with IC 50 = 1.9-7.4 μM. For these compounds, binding sites and conformations in the BRD4 (4UYD) have been determined by docking. Copyright © 2018 Elsevier Ltd. All rights reserved.
Basu, Partha; Meheus, Filip; Chami, Youssef; Hariprasad, Roopa; Zhao, Fanghui; Sankaranarayanan, Rengaswamy
2017-07-01
Management algorithms for screen-positive women in cervical cancer prevention programs have undergone substantial changes in recent years. The WHO strongly recommends human papillomavirus (HPV) testing for primary screening, if affordable, or if not, then visual inspection with acetic acid (VIA), and promotes treatment directly following screening through the screen-and-treat approach (one or two clinic visits). While VIA-positive women can be offered immediate ablative treatment based on certain eligibility criteria, HPV-positive women need to undergo subsequent VIA to determine their eligibility. Simpler ablative methods of treatment such as cryotherapy and thermal coagulation have been demonstrated to be effective and to have excellent safety profiles, and these have become integral parts of new management algorithms. The challenges faced by low-resource countries are many and include, from the management perspective, identifying an affordable point-of-care HPV detection test, minimizing over-treatment, and installing an effective information system to ensure high compliance to treatment and follow-up. © 2017 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics.
Exploring virtual worlds with head-mounted displays
NASA Astrophysics Data System (ADS)
Chung, James C.; Harris, Mark R.; Brooks, F. P.; Fuchs, Henry; Kelley, Michael T.
1989-02-01
Research has been conducted in the use of simple head mounted displays in real world applications. Such units provide the user with non-holographic true 3-D information, since the kinetic depth effect, stereoscopy, and other visual cues combine to immerse the user in a virtual world which behaves like the real world in some respects. UNC's head mounted display was built inexpensively from commercially available off-the-shelf components. Tracking of the user's head position and orientation is performed by a Polhemus Navigation Sciences' 3SPACE tracker. The host computer uses the tracking information to generate updated images corresponding to the user's new left eye and right eye views. The images are broadcast to two liquid crystal television screens (220x320 pixels) mounted on a horizontal shelf at the user's forehead. The user views these color screens through half-silvered mirrors, enabling the computer generated image to be superimposed upon the user's real physical environment. The head mounted display was incorporated into existing molecular and architectural applications being developed at UNC. In molecular structure studies, chemists are presented with a room sized molecule with which they can interact in a manner more intuitive than that provided by conventional 2-D displays and dial boxes. Walking around and through the large molecule may provide quicker understanding of its structure, and such problems as drug enzyme docking may be approached with greater insight.
Electroanalytical applications of screen-printable surfactant-induced sol-gel graphite composites
Guadalupe, Ana R.; Guo, Yizhu
2001-05-15
A process for preparing sol-gel graphite composite electrodes is presented. This process preferably uses the surfactant bis(2-ethylhexyl) sulfosuccinate (AOT) and eliminates the need for a cosolvent, an acidic catalyst, a cellulose binder and a thermal curing step from prior art processes. Fabrication of screen-printed electrodes by this process provides a simple approach for electroanalytical applications in aqueous and nonaqueous solvents. Examples of applications for such composite electrodes produced from this process include biochemical sensors such as disposable, single-use glucose sensors and ligand modified composite sensors for metal ion sensitive sensors.
Advanced Gas Turbine (AGT) powertrain system development for automotive applications
NASA Technical Reports Server (NTRS)
1982-01-01
Topics covered include the AGT 101 engine test; compressor design modification; cold air turbine testing; Mod 1 alloy turbine rotor fabrication; combustion aspects; regenerator development; and thermal screening tests for ceramic materials. The foil gas bearings, rotor dynamics, and AGT controls and accessories are also considered.
Dish-based CPV-T for rooftop generation
NASA Astrophysics Data System (ADS)
Davila-Peralta, Christian; Hyatt, Justin; Alfred, Dan; Struble, Morgan; Sodari, Frank; Angel, Roger
2017-09-01
Hybrid CPV-T with combined electrical and thermal output is well suited to solar generation from fixed limited areas, such as on the roof of an industrial or commercial facility with need for heat. This application will become especially attractive once overall electrical conversion efficiency of 40% is reached, as is projected for REhnu CPV systems using multijunction cells of 50% efficiency, anticipated in a few years. We outline here a configuration of dish- based CPV trackers optimized for close packing on a flat roof in a triangular grid, with a mirror area-to-ground area ratio of 50%. When the geometry of shadowing averaged over a year is taken into account, 80% of all the sunlight that would strike the rooftop is directed into the receivers. Such an array on a given area of flat roof will generate more electrical energy than would be possible with conventional PV panels, even if covering the entire rooftop, because of silicon's relative inefficiency. For example, in Tucson, the annual average global flux of 5.7 kWh/m2/day on a horizontal surface covered with 22% silicon modules will yield 1.25 kWh/m2/day. We show that a CPV system collecting 80% of all the direct sunlight of 7.0 kWh/m2 and converting it with 40% efficiency will yield 2.24 kWh/m2/day of rooftop area, nearly twice as much4. Thermal power will double again the total energy yield. A dual axis CPV-T tracker designed specifically very close spacing has been built to carry a single dish mirror of the standard type used in REhnu's M-8 generator, described by Stalcup et al in these proceedings1,2. Sunlight is collected and focused by a single square paraboloidal mirror, 1.65 × 1.65 m with focal length of 1.5 m. For closest possible packing without mechanical interference, and for broad distribution of load on a rooftop, the mirror and receiver are mounted to a C-ring structure, configured such that the elevation and azimuth axes intersect at a virtual pivot, at the center of the sphere that just clears the receiver and the corners of the mirror. Initial tests of closed loop tracking show an accuracy of 0.03° rms under calm conditions, and 0.04° rms in 6 m/sec wind.
Individual Differences in the Attribution of Incentive Salience to a Pavlovian Alcohol Cue
Villaruel, Franz R.; Chaudhri, Nadia
2016-01-01
Individual differences exist in the attribution of incentive salience to conditioned stimuli associated with food. Here, we investigated whether individual differences also manifested with a Pavlovian alcohol conditioned stimulus (CS). We compiled data from five experiments that used a Pavlovian autoshaping paradigm and tests of conditioned reinforcement. In all experiments, male, Long-Evans rats with unrestricted access to food and water were acclimated to 15% ethanol. Next, rats received Pavlovian autoshaping training, in which a 10 s presentation of a retractable lever served as the CS and 0.2 mL of 15% ethanol served as the unconditioned stimulus (US). Finally, rats underwent conditioned reinforcement tests in which nose-pokes to an active aperture led to brief presentations of the lever-CS, but nose-pokes to an inactive aperture had no consequence. Rats were categorized as sign-trackers, goal-trackers and intermediates based on a response bias score that reflected their tendencies to sign-track or goal-track at different times during training. We found that distinct groups of rats either consistently interacted with the lever-CS (“sign-trackers”) or routinely approached the port during the lever-CS (“goal-trackers”) across a majority of the training sessions. However, some individuals (“shifted sign-trackers”) with an early tendency to goal-track later shifted to comparable asymptotic levels of sign-tracking as the group identified as sign-trackers. The lever-CS functioned as a conditioned reinforcer for sign-trackers and shifted sign-trackers, but not for goal-trackers. These results provide evidence of robust individual differences in the extent to which a Pavlovian alcohol cue gains incentive salience and functions as a conditioned reinforcer. PMID:28082877
Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries.
DeHoff, Paul H; Barrett, Allyson A; Lee, Robert B; Anusavice, Kenneth J
2008-06-01
To test the hypothesis that bilayer ceramic cylinders and spheres can provide valid confirmation of thermal incompatibility stresses predicted by finite element analyses. A commercial core ceramic and an experimental core ceramic were used to fabricate open-ended cylinders and core ceramic spheres. The core cylinders and spheres were veneered with one of four commercial dental ceramics representing four thermally compatible groups and four thermally incompatible groups. Axisymmetric thermal and viscoelastic elements in the ANSYS finite element program were used to calculate temperatures and stresses for each geometry and ceramic combination. This process required a transient heat transfer analysis for each combination to determine input temperatures for the structural model. After fabrication, each specimen was examined visually using fiberoptic transillumination for evidence of cracking. There were 100% failures of the thermally incompatible cylinders while none of the thermally compatible combinations failed. Among the spheres, 100% of the thermally incompatible systems failed, 16% of one of the thermally compatible systems failed, and none of the remaining compatible combinations failed. The calculated stress values were in general agreement with the experimental observations, i.e., low residual stresses for the specimens that did not fail and high residual stresses for the specimens that did fail. Simple screening geometries can be used to identify highly incompatible ceramic combinations, but they do not identify marginally incompatible systems.
Thermal compatibility of dental ceramic systems using cylindrical and spherical geometries
DeHoff, Paul H.; Barrett, Allyson A.; Lee, Robert B.; Anusavice, Kenneth J.
2009-01-01
Objective To test the hypothesis that bilayer ceramic cylinders and spheres can provide valid confirmation of thermal incompatibility stresses predicted by finite element analyses. Methods A commercial core ceramic and an experimental core ceramic were used to fabricate open-ended cylinders and core ceramic spheres. The core cylinders and spheres were veneered with one of four commercial dental ceramics representing four thermally compatible groups and four thermally incompatible groups. Axisymmetric thermal and viscoelastic elements in the ANSYS finite element program were used to calculate temperatures and stresses for each geometry and ceramic combination. This process required a transient heat transfer analysis for each combination to determine input temperatures for the structural model. Results After fabrication, each specimen was examined visually using fiberoptic transillumination for evidence of cracking. There were 100% failures of the thermally incompatible cylinders while none of the thermally compatible combinations failed. Among the spheres, 100% of the thermally incompatible systems failed, 16% of one of the thermally compatible systems failed, and none of the remaining compatible combinations failed. The calculated stress values were in general agreement with the experimental observations, i.e., low residual stresses for the specimens that did not fail and high residual stresses for the specimens that did fail. Significance Simple screening geometries can be used to identify highly incompatible ceramic combinations, but they do not identify marginally incompatible systems. PMID:17949805
Tang, Runze; Zhang, Tonglai; Chen, Yongpeng; Liang, Hao; Li, Bingyang; Zhou, Zunning
2018-05-06
Effective shielding area is a crucial indicator for the evaluation of the infrared smoke-obscuring effectiveness on the battlefield. The conventional methods for assessing the shielding area of the smoke screen are time-consuming and labor intensive, in addition to lacking precision. Therefore, an efficient and convincing technique for testing the effective shielding area of the smoke screen has great potential benefits in the smoke screen applications in the field trial. In this study, a thermal infrared sensor with a mid-wavelength infrared (MWIR) range of 3 to 5 μm was first used to capture the target scene images through clear as well as obscuring smoke, at regular intervals. The background subtraction in motion detection was then applied to obtain the contour of the smoke cloud at each frame. The smoke transmittance at each pixel within the smoke contour was interpolated based on the data that was collected from the image. Finally, the smoke effective shielding area was calculated, based on the accumulation of the effective shielding pixel points. One advantage of this approach is that it utilizes only one thermal infrared sensor without any other additional equipment in the field trial, which significantly contributes to the efficiency and its convenience. Experiments have been carried out to demonstrate that this approach can determine the effective shielding area of the field infrared smoke both practically and efficiently.
Design of a high temperature subsurface thermal energy storage system
NASA Astrophysics Data System (ADS)
Zheng, Qi
Solar thermal energy is taking up increasing proportions of future power generation worldwide. Thermal energy storage technology is a key method for compensating for the inherent intermittency of solar resources and solving the time mismatch between solar energy supply and electricity demand. However, there is currently no cost-effective high-capacity compact storage technology available (Bakker et al., 2008). The goal of this work is to propose a high temperature subsurface thermal energy storage (HSTES) technology and demonstrate its potential energy storage capability by developing a solar-HSTES-electricity generation system. In this work, main elements of the proposed system and their related state-of-art technologies are reviewed. A conceptual model is built to illustrate the concept, design, operating procedure and application of such a system. A numerical base model is built within the TOUGH2-EOS1 multiphase flow simulator for the evaluation of system performance. Additional models are constructed and simulations are done to identify the effect of different operational and geological influential factors on the system performance. Our work shows that when the base model is run with ten years operation of alternate injection and production processes - each for a month - with a thermal power input of 10.85 MW, about 83% of the injected thermal energy could be recovered within each working cycle from a stabilized HSTES system. After the final conversion into electrical energy, a relative (compared with the direct use of hot water) electricity generation efficiency of 73% is obtained. In a typical daily storage scenario, the simulated thermal storage efficiency could exceed 78% and the relative electricity generation efficiency is over 66% in the long run. In a seasonal storage scenario, these two efficiencies reach 69% and 53% respectively by the end of the simulation period of 10 years. Additional simulations reveal a thinner storage aquifer with a higher horizontal-to-vertical permeability ratio is favored by the storage system. A basin-shape reservoir is more favored than a flat reservoir, while a flat reservoir is better than a dome-shape reservoir. The effect of aquifer stratification is variable: it depends on the relative position of the well screen and the impermeable lenses within the reservoir. From the operational aspect, the well screen position is crucial and properly shortening the screen length can help heat recovery. The proportion of the injection/storage/recovery processes within a cycle, rather than their exact lengths, affects the storage efficiency. Reservoir preheating helps improve the energy storage efficiency for the first several cycles. However, it does not contribute much to the system performance in the long run. Simulations also indicate that buoyancy effect is of significant importance in heat distribution and the plume migration. Reducing the gravity override effect of the heat plume could be an important consideration in efficiency optimization.
Study of thermal insulation for airborne liquid hydrogen fuel tanks
NASA Technical Reports Server (NTRS)
Ruccia, F. E.; Lindstrom, R. S.; Lucas, R. M.
1978-01-01
A concept for a fail-safe thermal protection system was developed. From screening tests, approximately 30 foams, adhesives, and reinforcing fibers using 0.3-meter square liquid nitrogen cold plate, CPR 452 and Stafoam AA1602, both reinforced with 10 percent by weight of 1/16 inch milled OCF Style 701 Fiberglas, were selected for further tests. Cyclic tests with these materials in 2-inch thicknesses bonded on a 0.6-meter square cold plate with Crest 7410 adhesive systems, were successful. Zero permeability gas barriers were identified and found to be compatible with the insulating concept.
Linked gas chromatograph-thermal energy analyzer/ion trap mass spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alcaraz, A.; Martin, W.H.; Andresen, B.D.
1991-05-01
The capability of comparing a nitrogen chromatogram generated from a gas chromatograph (GC, Varian model 3400) linked to a thermal energy analyzer (TEA, Thermedics Inc. Model 610) with a total ion chromatogram (from a Finnigan-MAT Ion Trap Mass Spectrometer, ITMS) has provided a new means to screen and identifying trace levels of nitrogen-containing compounds in complex mixtures. Prior to the work described here, it has not been possible to simultaneously acquire TEA and MS data. What was needed was a viable GC-TEA/ITMS interface to combine the capabilities of both instruments. 4 figs.
CPV Cell Infant Mortality Study
NASA Astrophysics Data System (ADS)
Bosco, Nick; Sweet, Cassi; Silverman, Timothy J.; Kurtz, Sarah
2011-12-01
Six hundred and fifty CPV cells were characterized before packaging and then after a four-hour concentrated on-sun exposure. An observed infant mortality failure rate was reproduced and attributed to epoxy die-attach voiding at the corners of the cells. These voids increase the local thermal resistance allowing thermal runaway to occur under normal operating conditions in otherwise defect-free cells. FEM simulations and experiments support this hypothesis. X-ray transmission imaging of the affected assemblies was found incapable of detecting all suspect voids and therefore cannot be considered a reliable screening technique in the case of epoxy die-attach.
78 FR 18563 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-27
... Tracker (SPOT) System; OMB Control Number 0704-0460. Needs and Uses: In accordance with section 861 of... data into the Synchronized Predeployment and Operational Tracker (SPOT) System before deployment... designated the SPOT as the joint Web- based database to assist the Combatant Commander (CCDR) in maintaining...
Oregon regional intelligent transportation systems (ITS) integration program. Final phase II report
DOT National Transportation Integrated Search
2002-07-12
The purpose of the Transit Tracker evaluation is to collect and analyze data related to a change in bus riders behaviors and perceptions of service and security as a result of the Transit Tracker information displays. Four measures of effectivenes...
DOT National Transportation Integrated Search
2003-11-14
Transit Tracker uses global positioning system (GPS) technology to track how far a bus is along its scheduled route. This document presents the evaluation strategies and objectives, the data collection methodologies, and the results of the evaluation...
A post-processing algorithm for time domain pitch trackers
NASA Astrophysics Data System (ADS)
Specker, P.
1983-01-01
This paper describes a powerful post-processing algorithm for time-domain pitch trackers. On two successive passes, the post-processing algorithm eliminates errors produced during a first pass by a time-domain pitch tracker. During the second pass, incorrect pitch values are detected as outliers by computing the distribution of values over a sliding 80 msec window. During the third pass (based on artificial intelligence techniques), remaining pitch pulses are used as anchor points to reconstruct the pitch train from the original waveform. The algorithm produced a decrease in the error rate from 21% obtained with the original time domain pitch tracker to 2% for isolated words and sentences produced in an office environment by 3 male and 3 female talkers. In a noisy computer room errors decreased from 52% to 2.9% for the same stimuli produced by 2 male talkers. The algorithm is efficient, accurate, and resistant to noise. The fundamental frequency micro-structure is tracked sufficiently well to be used in extracting phonetic features in a feature-based recognition system.
ASME B89.4.19 Performance Evaluation Tests and Geometric Misalignments in Laser Trackers
Muralikrishnan, B.; Sawyer, D.; Blackburn, C.; Phillips, S.; Borchardt, B.; Estler, W. T.
2009-01-01
Small and unintended offsets, tilts, and eccentricity of the mechanical and optical components in laser trackers introduce systematic errors in the measured spherical coordinates (angles and range readings) and possibly in the calculated lengths of reference artifacts. It is desirable that the tests described in the ASME B89.4.19 Standard [1] be sensitive to these geometric misalignments so that any resulting systematic errors are identified during performance evaluation. In this paper, we present some analysis, using error models and numerical simulation, of the sensitivity of the length measurement system tests and two-face system tests in the B89.4.19 Standard to misalignments in laser trackers. We highlight key attributes of the testing strategy adopted in the Standard and propose new length measurement system tests that demonstrate improved sensitivity to some misalignments. Experimental results with a tracker that is not properly error corrected for the effects of the misalignments validate claims regarding the proposed new length tests. PMID:27504211
Real-Time Visual Tracking through Fusion Features
Ruan, Yang; Wei, Zhenzhong
2016-01-01
Due to their high-speed, correlation filters for object tracking have begun to receive increasing attention. Traditional object trackers based on correlation filters typically use a single type of feature. In this paper, we attempt to integrate multiple feature types to improve the performance, and we propose a new DD-HOG fusion feature that consists of discriminative descriptors (DDs) and histograms of oriented gradients (HOG). However, fusion features as multi-vector descriptors cannot be directly used in prior correlation filters. To overcome this difficulty, we propose a multi-vector correlation filter (MVCF) that can directly convolve with a multi-vector descriptor to obtain a single-channel response that indicates the location of an object. Experiments on the CVPR2013 tracking benchmark with the evaluation of state-of-the-art trackers show the effectiveness and speed of the proposed method. Moreover, we show that our MVCF tracker, which uses the DD-HOG descriptor, outperforms the structure-preserving object tracker (SPOT) in multi-object tracking because of its high-speed and ability to address heavy occlusion. PMID:27347951
Kernelized correlation tracking with long-term motion cues
NASA Astrophysics Data System (ADS)
Lv, Yunqiu; Liu, Kai; Cheng, Fei
2018-04-01
Robust object tracking is a challenging task in computer vision due to interruptions such as deformation, fast motion and especially, occlusion of tracked object. When occlusions occur, image data will be unreliable and is insufficient for the tracker to depict the object of interest. Therefore, most trackers are prone to fail under occlusion. In this paper, an occlusion judgement and handling method based on segmentation of the target is proposed. If the target is occluded, the speed and direction of it must be different from the objects occluding it. Hence, the value of motion features are emphasized. Considering the efficiency and robustness of Kernelized Correlation Filter Tracking (KCF), it is adopted as a pre-tracker to obtain a predicted position of the target. By analyzing long-term motion cues of objects around this position, the tracked object is labelled. Hence, occlusion could be detected easily. Experimental results suggest that our tracker achieves a favorable performance and effectively handles occlusion and drifting problems.
Action-Driven Visual Object Tracking With Deep Reinforcement Learning.
Yun, Sangdoo; Choi, Jongwon; Yoo, Youngjoon; Yun, Kimin; Choi, Jin Young
2018-06-01
In this paper, we propose an efficient visual tracker, which directly captures a bounding box containing the target object in a video by means of sequential actions learned using deep neural networks. The proposed deep neural network to control tracking actions is pretrained using various training video sequences and fine-tuned during actual tracking for online adaptation to a change of target and background. The pretraining is done by utilizing deep reinforcement learning (RL) as well as supervised learning. The use of RL enables even partially labeled data to be successfully utilized for semisupervised learning. Through the evaluation of the object tracking benchmark data set, the proposed tracker is validated to achieve a competitive performance at three times the speed of existing deep network-based trackers. The fast version of the proposed method, which operates in real time on graphics processing unit, outperforms the state-of-the-art real-time trackers with an accuracy improvement of more than 8%.
NASA Astrophysics Data System (ADS)
Tykhonov, A.; Ambrosi, G.; Asfandiyarov, R.; Azzarello, P.; Bernardini, P.; Bertucci, B.; Bolognini, A.; Cadoux, F.; D'Amone, A.; De Benedittis, A.; De Mitri, I.; Di Santo, M.; Dong, Y. F.; Duranti, M.; D'Urso, D.; Fan, R. R.; Fusco, P.; Gallo, V.; Gao, M.; Gargano, F.; Garrappa, S.; Gong, K.; Ionica, M.; La Marra, D.; Lei, S. J.; Li, X.; Loparco, F.; Marsella, G.; Mazziotta, M. N.; Peng, W. X.; Qiao, R.; Salinas, M. M.; Surdo, A.; Vagelli, V.; Vitillo, S.; Wang, H. Y.; Wang, J. Z.; Wang, Z. M.; Wu, D.; Wu, X.; Zhang, F.; Zhang, J. Y.; Zhao, H.; Zimmer, S.
2018-06-01
The DArk Matter Particle Explorer (DAMPE) is a space-borne particle detector designed to probe electrons and gamma-rays in the few GeV to 10 TeV energy range, as well as cosmic-ray proton and nuclei components between 10 GeV and 100 TeV. The silicon-tungsten tracker-converter is a crucial component of DAMPE. It allows the direction of incoming photons converting into electron-positron pairs to be estimated, and the trajectory and charge (Z) of cosmic-ray particles to be identified. It consists of 768 silicon micro-strip sensors assembled in 6 double layers with a total active area of 6.6 m2. Silicon planes are interleaved with three layers of tungsten plates, resulting in about one radiation length of material in the tracker. Internal alignment parameters of the tracker have been determined on orbit, with non-showering protons and helium nuclei. We describe the alignment procedure and present the position resolution and alignment stability measurements.
High thermal conductivity liquid metal pad for heat dissipation in electronic devices
NASA Astrophysics Data System (ADS)
Lin, Zuoye; Liu, Huiqiang; Li, Qiuguo; Liu, Han; Chu, Sheng; Yang, Yuhua; Chu, Guang
2018-05-01
Novel thermal interface materials using Ag-doped Ga-based liquid metal were proposed for heat dissipation of electronic packaging and precision equipment. On one hand, the viscosity and fluidity of liquid metal was controlled to prevent leakage; on the other hand, the thermal conductivity of the Ga-based liquid metal was increased up to 46 W/mK by incorporating Ag nanoparticles. A series of experiments were performed to evaluate the heat dissipation performance on a CPU of smart-phone. The results demonstrated that the Ag-doped Ga-based liquid metal pad can effectively decrease the CPU temperature and change the heat flow path inside the smart-phone. To understand the heat flow path from CPU to screen through the interface material, heat dissipation mechanism was simulated and discussed.
Ultralow Thermal Conductivity in Full Heusler Semiconductors.
He, Jiangang; Amsler, Maximilian; Xia, Yi; Naghavi, S Shahab; Hegde, Vinay I; Hao, Shiqiang; Goedecker, Stefan; Ozoliņš, Vidvuds; Wolverton, Chris
2016-07-22
Semiconducting half and, to a lesser extent, full Heusler compounds are promising thermoelectric materials due to their compelling electronic properties with large power factors. However, intrinsically high thermal conductivity resulting in a limited thermoelectric efficiency has so far impeded their widespread use in practical applications. Here, we report the computational discovery of a class of hitherto unknown stable semiconducting full Heusler compounds with ten valence electrons (X_{2}YZ, X=Ca, Sr, and Ba; Y=Au and Hg; Z=Sn, Pb, As, Sb, and Bi) through high-throughput ab initio screening. These new compounds exhibit ultralow lattice thermal conductivity κ_{L} close to the theoretical minimum due to strong anharmonic rattling of the heavy noble metals, while preserving high power factors, thus resulting in excellent phonon-glass electron-crystal materials.
Bergsdorf, Christian; Fiez-Vandal, Cédric; Sykes, David A; Bernet, Pascal; Aussenac, Sonia; Charlton, Steven J; Schopfer, Ulrich; Ottl, Johannes; Duckely, Myriam
2016-03-01
Integral membrane proteins (IMPs) play an important role in many cellular events and are involved in numerous pathological processes. Therefore, understanding the structure and function of IMPs is a crucial prerequisite to enable successful targeting of these proteins with low molecular weight (LMW) ligands early on in the discovery process. To optimize IMP purification/crystallization and to identify/characterize LMW ligand-target interactions, robust, reliable, high-throughput, and sensitive biophysical methods are needed. Here, we describe a differential scanning fluorimetry (DSF) screening method using the thiol-reactive BODIPY FL-cystine dye to monitor thermal unfolding of the G-protein-coupled receptor (GPCR), CXCR2. To validate this method, the seven-transmembrane protein CXCR2 was analyzed with a set of well-characterized antagonists. This study showed that the new DSF assay assessed reliably the stability of CXCR2 in a 384-well format. The analysis of 14 ligands with a potency range over 4 log units demonstrated the detection/characterization of LMW ligands binding to the membrane protein target. Furthermore, DSF results cross-validated with the label-free differential static light scattering (DSLS) thermal denaturation method. These results underline the potential of the BODIPY assay format as a general tool to investigate membrane proteins and their interaction partners. © 2015 Society for Laboratory Automation and Screening.
Ensemble control of Kondo screening in molecular adsorbates
Maughan, Bret; Zahl, Percy; Sutter, Peter; ...
2017-04-06
Switching the magnetic properties of organic semiconductors on a metal surface has thus far largely been limited to molecule-by-molecule tip-induced transformations in scanned probe experiments. Here we demonstrate with molecular resolution that collective control of activated Kondo screening can be achieved in thin-films of the organic semiconductor titanyl phthalocyanine on Cu(110) to obtain tunable concentrations of Kondo impurities. Using low-temperature scanning tunneling microscopy and spectroscopy, we show that a thermally activated molecular distortion dramatically shifts surface–molecule coupling and enables ensemble-level control of Kondo screening in the interfacial spin system. This is accompanied by the formation of a temperature-dependent Abrikosov–Suhl–Kondo resonancemore » in the local density of states of the activated molecules. This enables coverage-dependent control over activation to the Kondo screening state. Finally, our study thus advances the versatility of molecular switching for Kondo physics and opens new avenues for scalable bottom-up tailoring of the electronic structure and magnetic texture of organic semiconductor interfaces at the nanoscale.« less
Characterization of the Ecosole HCPV tracker and single module inverter
NASA Astrophysics Data System (ADS)
Carpanelli, Maurizio; Borelli, Gianni; Verdilio, Daniele; De Nardis, Davide; Migali, Fabrizio; Cancro, Carmine; Graditi, Giorgio
2015-09-01
BECAR, the Beghelli group's R&D company, is leading ECOSOLE (Elevated COncentration SOlar Energy), one of the largest European Demonstration projects in solar photovoltaic. ECOSOLE, started in 2012, is focused on the study, design, and realization of new HCPV generator made of high efficiency PV modules equipped with SoG (Silicone on Glass) fresnel lenses and III-V solar cells, and a low cost matched solar tracker with distributed inverters approach. The project also regards the study and demonstration of new high throughput methods for the industrial large scale productions, at very low manufacturing costs. This work reports the description of the characterization of the tracker and single module.
Reconstruction software of the silicon tracker of DAMPE mission
NASA Astrophysics Data System (ADS)
Tykhonov, A.; Gallo, V.; Wu, X.; Zimmer, S.
2017-10-01
DAMPE is a satellite-borne experiment aimed to probe astroparticle physics in the GeV-TeV energy range. The Silicon tracker (STK) is one of the key components of DAMPE, which allows the reconstruction of trajectories (tracks) of detected particles. The non-negligible amount of material in the tracker poses a challenge to its reconstruction and alignment. In this paper we describe methods to address this challenge. We present the track reconstruction algorithm and give insight into the alignment algorithm. We also present our CAD-to-GDML converter, an in-house tool for implementing detector geometry in the software from the CAD drawings of the detector.
P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC
NASA Astrophysics Data System (ADS)
Adam, W.; Bergauer, T.; Brondolin, E.; Dragicevic, M.; Friedl, M.; Frühwirth, R.; Hoch, M.; Hrubec, J.; König, A.; Steininger, H.; Waltenberger, W.; Alderweireldt, S.; Beaumont, W.; Janssen, X.; Lauwers, J.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Beghin, D.; Brun, H.; Clerbaux, B.; Delannoy, H.; De Lentdecker, G.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, Th.; Léonard, A.; Luetic, J.; Postiau, N.; Seva, T.; Vanlaer, P.; Vannerom, D.; Wang, Q.; Zhang, F.; Abu Zeid, S.; Blekman, F.; De Bruyn, I.; De Clercq, J.; D'Hondt, J.; Deroover, K.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Van Mulders, P.; Van Parijs, I.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caudron, A.; Delaere, C.; Delcourt, M.; De Visscher, S.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Michotte, D.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Szilasi, N.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Caebergs, T.; Daubie, E.; Hammad, G. H.; Härkönen, J.; Lampén, T.; Luukka, P.; Peltola, T.; Tuominen, E.; Tuovinen, E.; Eerola, P.; Tuuva, T.; Baulieu, G.; Boudoul, G.; Caponetto, L.; Combaret, C.; Contardo, D.; Dupasquier, T.; Gallbit, G.; Lumb, N.; Mirabito, L.; Perries, S.; Vander Donckt, M.; Viret, S.; Agram, J.-L.; Andrea, J.; Bloch, D.; Bonnin, C.; Brom, J.-M.; Chabert, E.; Chanon, N.; Charles, L.; Conte, E.; Fontaine, J.-Ch.; Gross, L.; Hosselet, J.; Jansova, M.; Tromson, D.; Autermann, C.; Feld, L.; Karpinski, W.; Kiesel, K. M.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Pierschel, G.; Preuten, M.; Rauch, M.; Schael, S.; Schomakers, C.; Schulz, J.; Schwering, G.; Wlochal, M.; Zhukov, V.; Pistone, C.; Fluegge, G.; Kuensken, A.; Pooth, O.; Stahl, A.; Aldaya, M.; Asawatangtrakuldee, C.; Beernaert, K.; Bertsche, D.; Contreras-Campana, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Gallo, E.; Garay Garcia, J.; Hansen, K.; Haranko, M.; Harb, A.; Hauk, J.; Keaveney, J.; Kalogeropoulos, A.; Kleinwort, C.; Lohmann, W.; Mankel, R.; Maser, H.; Mittag, G.; Muhl, C.; Mussgiller, A.; Pitzl, D.; Reichelt, O.; Savitskyi, M.; Schuetze, P.; Walsh, R.; Zuber, A.; Biskop, H.; Buhmann, P.; Centis-Vignali, M.; Garutti, E.; Haller, J.; Hoffmann, M.; Lapsien, T.; Matysek, M.; Perieanu, A.; Scharf, Ch.; Schleper, P.; Schmidt, A.; Schwandt, J.; Sonneveld, J.; Steinbrück, G.; Vormwald, B.; Wellhausen, J.; Abbas, M.; Amstutz, C.; Barvich, T.; Barth, Ch.; Boegelspacher, F.; De Boer, W.; Butz, E.; Caselle, M.; Colombo, F.; Dierlamm, A.; Freund, B.; Hartmann, F.; Heindl, S.; Husemann, U.; Kornmayer, A.; Kudella, S.; Muller, Th.; Simonis, H. J.; Steck, P.; Weber, M.; Weiler, Th.; Anagnostou, G.; Asenov, P.; Assiouras, P.; Daskalakis, G.; Kyriakis, A.; Loukas, D.; Paspalaki, L.; Siklér, F.; Veszprémi, V.; Bhardwaj, A.; Dalal, R.; Jain, G.; Ranjan, K.; Bakhshiansohl, H.; Behnamian, H.; Khakzad, M.; Naseri, M.; Cariola, P.; Creanza, D.; De Palma, M.; De Robertis, G.; Fiore, L.; Franco, M.; Loddo, F.; Silvestris, L.; Maggi, G.; Martiradonna, S.; My, S.; Selvaggi, G.; Albergo, S.; Cappello, G.; Chiorboli, M.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Saizu, M. A.; Tricomi, A.; Tuve, C.; Barbagli, G.; Brianzi, M.; Ciaranfi, R.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Latino, G.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Scarlini, E.; Sguazzoni, G.; Strom, D.; Viliani, L.; Ferro, F.; Lo Vetere, M.; Robutti, E.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Pedrini, D.; Azzi, P.; Bacchetta, N.; Bisello, D.; Dall'Osso, M.; Pozzobon, N.; Tosi, M.; De Canio, F.; Gaioni, L.; Manghisoni, M.; Nodari, B.; Riceputi, E.; Re, V.; Traversi, G.; Comotti, D.; Ratti, L.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Checcucci, B.; Ciangottini, D.; Fanò, L.; Gentsos, C.; Ionica, M.; Leonardi, R.; Manoni, E.; Mantovani, G.; Marconi, S.; Mariani, V.; Menichelli, M.; Modak, A.; Morozzi, A.; Moscatelli, F.; Passeri, D.; Placidi, P.; Postolache, V.; Rossi, A.; Saha, A.; Santocchia, A.; Storchi, L.; Spiga, D.; Androsov, K.; Azzurri, P.; Arezzini, S.; Bagliesi, G.; Basti, A.; Boccali, T.; Borrello, L.; Bosi, F.; Castaldi, R.; Ciampa, A.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Magazzu, G.; Martini, L.; Mazzoni, E.; Messineo, A.; Moggi, A.; Morsani, F.; Palla, F.; Palmonari, F.; Raffaelli, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Bellan, R.; Costa, M.; Covarelli, R.; Da Rocha Rolo, M.; Demaria, N.; Rivetti, A.; Dellacasa, G.; Mazza, G.; Migliore, E.; Monteil, E.; Pacher, L.; Ravera, F.; Solano, A.; Fernandez, M.; Gomez, G.; Jaramillo Echeverria, R.; Moya, D.; Gonzalez Sanchez, F. J.; Vila, I.; Virto, A. L.; Abbaneo, D.; Ahmed, I.; Albert, E.; Auzinger, G.; Berruti, G.; Bianchi, G.; Blanchot, G.; Bonnaud, J.; Caratelli, A.; Ceresa, D.; Christiansen, J.; Cichy, K.; Daguin, J.; D'Auria, A.; Detraz, S.; Deyrail, D.; Dondelewski, O.; Faccio, F.; Frank, N.; Gadek, T.; Gill, K.; Honma, A.; Hugo, G.; Jara Casas, L. M.; Kaplon, J.; Kornmayer, A.; Kottelat, L.; Kovacs, M.; Krammer, M.; Lenoir, P.; Mannelli, M.; Marchioro, A.; Marconi, S.; Mersi, S.; Martina, S.; Michelis, S.; Moll, M.; Onnela, A.; Orfanelli, S.; Pavis, S.; Peisert, A.; Pernot, J.-F.; Petagna, P.; Petrucciani, G.; Postema, H.; Rose, P.; Tropea, P.; Troska, J.; Tsirou, A.; Vasey, F.; Vichoudis, P.; Verlaat, B.; Zwalinski, L.; Bachmair, F.; Becker, R.; di Calafiori, D.; Casal, B.; Berger, P.; Djambazov, L.; Donega, M.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meinhard, M.; Perozzi, L.; Roeser, U.; Starodumov, A.; Tavolaro, V.; Wallny, R.; Zhu, D.; Amsler, C.; Bösiger, K.; Caminada, L.; Canelli, F.; Chiochia, V.; de Cosa, A.; Galloni, C.; Hreus, T.; Kilminster, B.; Lange, C.; Maier, R.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Taroni, S.; Yang, Y.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Kaestli, H.-C.; Kotlinski, D.; Langenegger, U.; Meier, B.; Rohe, T.; Streuli, S.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Jacob, J.; Seif El Nasr-Storey, S.; Cole, J.; Hoad, C.; Hobson, P.; Morton, A.; Reid, I. D.; Auzinger, G.; Bainbridge, R.; Dauncey, P.; Hall, G.; James, T.; Magnan, A.-M.; Pesaresi, M.; Raymond, D. M.; Uchida, K.; Garabedian, A.; Heintz, U.; Narain, M.; Nelson, J.; Sagir, S.; Speer, T.; Swanson, J.; Tersegno, D.; Watson-Daniels, J.; Chertok, M.; Conway, J.; Conway, R.; Flores, C.; Lander, R.; Pellett, D.; Ricci-Tam, F.; Squires, M.; Thomson, J.; Yohay, R.; Burt, K.; Ellison, J.; Hanson, G.; Olmedo, M.; Si, W.; Yates, B. R.; Gerosa, R.; Sharma, V.; Vartak, A.; Yagil, A.; Zevi Della Porta, G.; Dutta, V.; Gouskos, L.; Incandela, J.; Kyre, S.; Mullin, S.; Patterson, A.; Qu, H.; White, D.; Dominguez, A.; Bartek, R.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Apresyan, A.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cheung, H. W. K.; Chramowicz, J.; Christian, D.; Cooper, W. E.; Deptuch, G.; Derylo, G.; Gingu, C.; Grünendahl, S.; Hasegawa, S.; Hoff, J.; Howell, J.; Hrycyk, M.; Jindariani, S.; Johnson, M.; Kahlid, F.; Lei, C. M.; Lipton, R.; Lopes De Sá, R.; Liu, T.; Los, S.; Matulik, M.; Merkel, P.; Nahn, S.; Prosser, A.; Rivera, R.; Schneider, B.; Sellberg, G.; Shenai, A.; Spiegel, L.; Tran, N.; Uplegger, L.; Voirin, E.; Berry, D. R.; Chen, X.; Ennesser, L.; Evdokimov, A.; Evdokimov, O.; Gerber, C. E.; Hofman, D. J.; Makauda, S.; Mills, C.; Sandoval Gonzalez, I. D.; Alimena, J.; Antonelli, L. J.; Francis, B.; Hart, A.; Hill, C. S.; Parashar, N.; Stupak, J.; Bortoletto, D.; Bubna, M.; Hinton, N.; Jones, M.; Miller, D. H.; Shi, X.; Tan, P.; Baringer, P.; Bean, A.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Wilson, G.; Ivanov, A.; Mendis, R.; Mitchell, T.; Skhirtladze, N.; Taylor, R.; Anderson, I.; Fehling, D.; Gritsan, A.; Maksimovic, P.; Martin, C.; Nash, K.; Osherson, M.; Swartz, M.; Xiao, M.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Monroy, J.; Siado, J.; Hahn, K.; Sevova, S.; Sung, K.; Trovato, M.; Bartz, E.; Gershtein, Y.; Halkiadakis, E.; Kyriacou, S.; Lath, A.; Nash, K.; Osherson, M.; Schnetzer, S.; Stone, R.; Walker, M.; Malik, S.; Norberg, S.; Ramirez Vargas, J. E.; Alyari, M.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Kharchilava, A.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; McDermott, K.; Mirman, N.; Rinkevicius, A.; Ryd, A.; Salvati, E.; Skinnari, L.; Soffi, L.; Tao, Z.; Thom, J.; Tucker, J.; Zientek, M.; Akgün, B.; Ecklund, K. M.; Kilpatrick, M.; Nussbaum, T.; Zabel, J.; Betchart, B.; Covarelli, R.; Demina, R.; Hindrichs, O.; Petrillo, G.; Eusebi, R.; Osipenkov, I.; Perloff, A.; Ulmer, K. A.
2017-06-01
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.
Using "Tracker" to Prove the Simple Harmonic Motion Equation
ERIC Educational Resources Information Center
Kinchin, John
2016-01-01
Simple harmonic motion (SHM) is a common topic for many students to study. Using the free, though versatile, motion tracking software; "Tracker", we can extend the students experience and show that the general equation for SHM does lead to the correct period of a simple pendulum.
Radar Detection of Marine Mammals
2010-09-30
associative tracker using the Munkres algorithm was used. This was then expanded to include a track - before - detect algorithm, the Baysean Field...small, slow moving objects (i.e. whales). In order to address the third concern (M2 mode), we have tested using a track - before - detect tracker termed
Summer 1980 Directory of Navy Electro-Optical Professionals.
1981-01-19
4864 E-0 Oceanographic Applications Pressman , A. 335 4864 Satellite Analysis-, Environinental/Intelligence Tooma. S, 332 4810 E-0 Measurement of Sea...Teate. George 3924 372 1/ TV Trackers 3722 Teppo, E. A. 3151 3723 Laser Technology Thomas, Virgil 31404 5283 TV Camera/Trackers Thompson, Barry 3943
75 FR 45093 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-02
...; student tracker database updates, 16 hours. Burden Hours: 11,328. Needs and Uses: Under the authority of... application, by academic professors/advisors. NOAA OEd student scholar alumni are also requested to provide... tracker database with the required student information. In addition, the collected student data supports...
Analysis and research on thermal infrared properties and adaptability of the camouflage net
NASA Astrophysics Data System (ADS)
Cui, Guangzhen; Hu, Jianghua; Jian, Chaochao; Yang, Juntang
2016-10-01
As camouflage equipment, camouflage net which covers or obstruct the enemy reconnaissance and attack, have the compatibility such as optics, infrared, radar wave band performance. To improve the adaptive between the camouflage net with background in infrared wavelengths, the heat shield and heat integration requirements on the surface of the camouflage net was analyzed. The condition that satisfied the heat shield was when the average thermal infrared transmittance was less than 25.38% on camouflage screen surface. Studies have shown that camouflage nets and the background field fused together when infrared radiation temperature difference control is within the scope of ± 4K . Experiment on temperature contrast was tested in situ background, thermal camouflage spots and camouflage net with sponge material, the infrared heat maps was recorded in the period of experiment through the thermal imager. Results showed that the thermal inertia of camouflage net was markedly lower than the background and the exposed signs were obvious. It was difficult to reach camouflage thermal infrared fusion requirements by relying on camouflage spot emissivity, but sponge which mix with polymer resin can reduce target significance in the context of mottled and realize the fusion effect.
Uncertainty estimation and multi sensor fusion for kinematic laser tracker measurements
NASA Astrophysics Data System (ADS)
Ulrich, Thomas
2013-08-01
Laser trackers are widely used to measure kinematic tasks such as tracking robot movements. Common methods to evaluate the uncertainty in the kinematic measurement include approximations specified by the manufacturers, various analytical adjustment methods and the Kalman filter. In this paper a new, real-time technique is proposed, which estimates the 4D-path (3D-position + time) uncertainty of an arbitrary path in space. Here a hybrid system estimator is applied in conjunction with the kinematic measurement model. This method can be applied to processes, which include various types of kinematic behaviour, constant velocity, variable acceleration or variable turn rates. The new approach is compared with the Kalman filter and a manufacturer's approximations. The comparison was made using data obtained by tracking an industrial robot's tool centre point with a Leica laser tracker AT901 and a Leica laser tracker LTD500. It shows that the new approach is more appropriate to analysing kinematic processes than the Kalman filter, as it reduces overshoots and decreases the estimated variance. In comparison with the manufacturer's approximations, the new approach takes account of kinematic behaviour with an improved description of the real measurement process and a reduction in estimated variance. This approach is therefore well suited to the analysis of kinematic processes with unknown changes in kinematic behaviour as well as the fusion among laser trackers.
Liu, Jun; Liu, Wenjing; Yang, Jun
2016-02-11
We confirmed that ATP is released from cochlear marginal cells in the stria vascular but the cell organelle in which ATP stores was not identified until now. Thus, we studied the ATP-containing cell organelles and suggest that these are lysosomes. Primary cultures of marginal cells of Sprague-Dawley rats aged 1-3 days was established. Vesicles within marginal cells stained with markers were identified under confocal laser scanning microscope and transmission electron microscope (TEM). Then ATP release from marginal cells was measured after glycyl-L-phenylalanine-ß- naphthylamide (GPN) treatment using a bioluminescent assay. Quinacrine-stained granules within marginal cells were labeled with LysoTracker, a lysosome tracer, and lysosomal-associated membrane protein 1(LAMP1), but not labeled with the mitochondrial tracer MitoTracker. Furthermore, LysoTracker-labelled puncta showed accumulation of Mant-ATP, an ATP analog. Treatment with 200 μM GPN quenched fluorescently labeled puncta after incubation with LysoTracker or quinacrine, but not MitoTracker. Quinacrine-labeled organelles observed by TEM were lysosomes, and an average 27.7 percent increase in ATP luminescence was observed in marginal cells extracellular fluid after GPN treatment. ATP-containing vesicles in cochlear marginal cells of the stria vascular from neonatal rats are likely lysosomes. ATP release from marginal cells may be via Ca(2+)-dependent lysosomal exocytosis.