Self-interference between forward and backward propagating parts of a single acoustic plate mode
NASA Astrophysics Data System (ADS)
Germano, M.; Alippi, A.; Angelici, M.; Bettucci, A.
2002-04-01
Near and far fields of a particular (S1) Lamb mode, generated on a steel plate by means of a wedge transducer, are investigated. These show an oscillating behavior of the radial profile of the acoustic field amplitude that can be interpreted and modelled as interference phenomenon between forward and backward propagating parts of the Lamb mode, simultaneously generated at the interface between transducer and plate.
Self-interference between forward and backward propagating parts of a single acoustic plate mode.
Germano, M; Alippi, A; Angelici, M; Bettucci, A
2002-04-01
Near and far fields of a particular (S(1)) Lamb mode, generated on a steel plate by means of a wedge transducer, are investigated. These show an oscillating behavior of the radial profile of the acoustic field amplitude that can be interpreted and modelled as interference phenomenon between forward and backward propagating parts of the Lamb mode, simultaneously generated at the interface between transducer and plate.
He, Jianpeng; Dixon, Steve; Hill, Samuel; Xu, Ke
2017-01-01
Electromagnetic acoustic transducers (EMATs) are non-contact, ultrasonic transducers that are usually kept within 5 mm from the sample surface to obtain a sufficient signal-to-noise ratio (SNR). One important issue associated with operation on a ferromagnetic plate is that the strong attraction force from the magnet can affect measurements and make scanning difficult. This paper investigates a method to generate fundamental, symmetric Lamb waves on a ferromagnetic plate. A coil-only, low-weight, generation EMAT is designed and investigated, operating at lift-offs of over 5 mm. Another design of an EMAT is investigated using a rectangular magnet with a much higher lift-off than the coil, of up to 19 mm. This results in a much lower force between the EMAT and sample, making scanning the EMAT much easier. PMID:28471377
Low-cost ultrasonic lamb-wave transducer
NASA Technical Reports Server (NTRS)
Kammerer, C. C.
1978-01-01
Transducer propagates Lamb wave through thin aluminum sheet material. Model includes two elements that measure effects of damping and loading which, in turn, are indirectly equated to bond integrity. Transducer has been used to evaluate bond integrity of aluminum facing adhesively bonded to aluminum facing. Because of versatility, it is now possible to inspect many objects of different configurations that could not be reached with earlier transducers.
Defect Detection on Carbon Fibre Reinforced Plastics (cfrp) with Laser Generated Lamb Waves
NASA Astrophysics Data System (ADS)
Focke, O.; Huke, P.; Hildebrandt, A.
2011-06-01
Standard ultrasound methods using a phased-array or a single transducer are commonly used for non-destructive evaluation (NDE) during manufacturing of carbon fiber reinforced plastics (CFRP) parts and certificated testing schemes were developed for individual parts and geometries. However, most testing methods need direct contact, matching gels and remain therefore time consuming. Laser-Ultrasonics is advantageous due to the contactless measurement technology and high accessibility even on complex parts. Despite the non-destructive testing with body waves, we show that the NDE can be expanded using two-dimensional surface (Lamb) waves for detection of delaminations close to the surface or small deteriorations caused by e.g. impacts. Lamb waves have been excited with a single transducer and with a short-pulse Laser with additionally producing A0-and S0-Lamb waves. The waves were detected with a shearography setup that allows for measuring two-dimensionally the displacement of a surface. Short integration times of the camera were realized using a pulsed ruby laser for illumination. As a consequence to the anisotropy the propagation in different directions exhibits individual characteristics like amplitude, damping and velocity. This has motivated to build up models for the propagation of Lamb waves and to compare them with experimental results.
Directional nonlinear guided wave mixing: Case study of counter-propagating shear horizontal waves
NASA Astrophysics Data System (ADS)
Hasanian, Mostafa; Lissenden, Cliff J.
2018-04-01
While much nonlinear ultrasonics research has been conducted on higher harmonic generation, wave mixing provides the potential for sensitive measurements of incipient damage unencumbered by instrumentation nonlinearity. Studies of nonlinear ultrasonic wave mixing, both collinear and noncollinear, for bulk waves have shown the robust capability of wave mixing for early damage detection. One merit of bulk wave mixing lies in their non-dispersive nature, but guided waves enable inspection of otherwise inaccessible material and a variety of mixing options. Co-directional guided wave mixing was studied previously, but arbitrary direction guided wave mixing has not been addressed until recently. Wave vector analysis is applied to study variable mixing angles to find wave mode triplets (two primary waves and a secondary wave) resulting in the phase matching condition. As a case study, counter-propagating Shear Horizontal (SH) guided wave mixing is analyzed. SH wave interactions generate a secondary Lamb wave mode that is readily receivable. Reception of the secondary Lamb wave mode is compared for an angle beam transducer, an air coupled transducer, and a laser Doppler vibrometer (LDV). Results from the angle beam and air coupled transducers are quite consistent, while the LDV measurement is plagued by variability issues.
The propagation of Lamb waves in multilayered plates: phase-velocity measurement
NASA Astrophysics Data System (ADS)
Grondel, Sébastien; Assaad, Jamal; Delebarre, Christophe; Blanquet, Pierrick; Moulin, Emmanuel
1999-05-01
Owing to the dispersive nature and complexity of the Lamb waves generated in a composite plate, the measurement of the phase velocities by using classical methods is complicated. This paper describes a measurement method based upon the spectrum-analysis technique, which allows one to overcome these problems. The technique consists of using the fast Fourier transform to compute the spatial power-density spectrum. Additionally, weighted functions are used to increase the probability of detecting the various propagation modes. Experimental Lamb-wave dispersion curves of multilayered plates are successfully compared with the analytical ones. This technique is expected to be a useful way to design composite parts integrating ultrasonic transducers in the field of health monitoring. Indeed, Lamb waves and particularly their velocities are very sensitive to defects.
Modelling ultrasound guided wave propagation for plate thickness measurement
NASA Astrophysics Data System (ADS)
Malladi, Rakesh; Dabak, Anand; Murthy, Nitish Krishna
2014-03-01
Structural Health monitoring refers to monitoring the health of plate-like walls of large reactors, pipelines and other structures in terms of corrosion detection and thickness estimation. The objective of this work is modeling the ultrasonic guided waves generated in a plate. The piezoelectric is excited by an input pulse to generate ultrasonic guided lamb waves in the plate that are received by another piezoelectric transducer. In contrast with existing methods, we develop a mathematical model of the direct component of the signal (DCS) recorded at the terminals of the piezoelectric transducer. The DCS model uses maximum likelihood technique to estimate the different parameters, namely the time delay of the signal due to the transducer delay and amplitude scaling of all the lamb wave modes due to attenuation, while taking into account the received signal spreading in time due to dispersion. The maximum likelihood estimate minimizes the energy difference between the experimental and the DCS model-generated signal. We demonstrate that the DCS model matches closely with experimentally recorded signals and show it can be used to estimate thickness of the plate. The main idea of the thickness estimation algorithm is to generate a bank of DCS model-generated signals, each corresponding to a different thickness of the plate and then find the closest match among these signals to the received signal, resulting in an estimate of the thickness of the plate. Therefore our approach provides a complementary suite of analytics to the existing thickness monitoring approaches.
Multimodal sparse reconstruction in guided wave imaging of defects in plates
NASA Astrophysics Data System (ADS)
Golato, Andrew; Santhanam, Sridhar; Ahmad, Fauzia; Amin, Moeness G.
2016-07-01
A multimodal sparse reconstruction approach is proposed for localizing defects in thin plates in Lamb wave-based structural health monitoring. The proposed approach exploits both the sparsity of the defects and the multimodal nature of Lamb wave propagation in plates. It takes into account the variation of the defects' aspect angles across the various transducer pairs. At low operating frequencies, only the fundamental symmetric and antisymmetric Lamb modes emanate from a transmitting transducer. Asymmetric defects scatter these modes and spawn additional converted fundamental modes. Propagation models are developed for each of these scattered and spawned modes arriving at the various receiving transducers. This enables the construction of modal dictionary matrices spanning a two-dimensional array of pixels representing potential defect locations in the region of interest. Reconstruction of the region of interest is achieved by inverting the resulting linear model using the group sparsity constraint, where the groups extend across the various transducer pairs and the different modes. The effectiveness of the proposed approach is established with finite-element scattering simulations of the fundamental Lamb wave modes by crack-like defects in a plate. The approach is subsequently validated with experimental results obtained from an aluminum plate with asymmetric defects.
Real-time nondestructive evaluation of fiber composite laminates using low-frequency Lamb waves
NASA Astrophysics Data System (ADS)
díAz Valdés, Sergio H.; Soutis, Costas
2002-05-01
Amid the nondestructive evaluation techniques available for the inspection of composite materials, only a few are suitable for implementation while the component is in service. The investigation examines the application of Lamb waves at low-frequency-thickness products for the detection of delaminations in thick composite laminates. Surface-mounted piezoelectric devices were excited with a tone burst to generate elastic waves in the structure. Experiments were carried out on composite beam specimens where wave propagation distances over 2 m were achieved and artificially induced delaminations as small as 1 cm2 were successfully identified. The feasibility of employing piezoelectric devices for the development of smart structures, where a small and lightweight transducer system design is required, has been demonstrated. The resonance spectrum method, which is based on the study of spectra obtained by forced mechanical resonance of samples using sine-sweep excitation, has been proposed as a technique for measuring the Ao Lamb mode phase velocity. The finite-element method was also used to investigate qualitatively the dynamic response of laminates to wave propagation. Several locations and spatial distribution of the actuators were examined showing the advantages of using transducers arrays for the inspection of large structures.
Development of dual PZT transducers for reference-free crack detection in thin plate structures.
Sohn, Hoon; Kim, Seuno Bum
2010-01-01
A new Lamb-wave-based nondestructive testing (NDT) technique, which does not rely on previously stored baseline data, is developed for crack monitoring in plate structures. Commonly, the presence of damage is identified by comparing "current data" measured from a potentially damaged stage of a structure with "baseline data" previously obtained at the intact condition of the structure. In practice, structural defects typically take place long after collection of the baseline data, and the baseline data can be also affected by external loading, temperature variations, and changing boundary conditions. To eliminate the dependence on the baseline data comparison, the authors previously developed a reference-free NDT technique using 2 pairs of collocated lead zirconate titanate (PZT) transducers placed on both sides of a plate. This reference-free technique is further advanced in the present study by the necessity of attaching transducers only on a single surface of a structure for certain applications such as aircraft. To achieve this goal, a new design of PZT transducers called dual PZT transducers is proposed. Crack formation creates Lamb wave mode conversion due to a sudden thickness change of the structure. This crack appearance is instantly detected from the measured Lamb wave signals using the dual PZT transducers. This study also suggests a reference-free statistical approach that enables damage classification using only the currently measured data set. Numerical simulations and experiments were conducted using an aluminum plate with uniform thickness and fundamental Lamb waves modes to demonstrate the applicability of the proposed technique to reference-free crack detection.
Excitation of plane Lamb wave in plate-like structures under applied surface loading
NASA Astrophysics Data System (ADS)
Zhou, Kai; Xu, Xinsheng; Zhao, Zhen; Yang, Zhengyan; Zhou, Zhenhuan; Wu, Zhanjun
2018-02-01
Lamb waves play an important role in structure health monitoring (SHM) systems. The excitation of Lamb waves has been discussed for a long time with absorbing results. However, little effort has been made towards the precise characterization of Lamb wave excitation by various transducer models with mathematical foundation. In this paper, the excitation of plane Lamb waves with plane strain assumption in isotropic plate structures under applied surface loading is solved with the Hamiltonian system. The response of the Lamb modes excited by applied loading is expressed analytically. The effect of applied loading is divided into the product of two parts as the effect of direction and the effect of distribution, which can be changed by selecting different types of transducer and the corresponding transducer configurations. The direction of loading determines the corresponding displacement of each mode. The effect of applied loading on the in-plane and normal directions depends on the in-plane and normal displacements at the surface respectively. The effect of the surface loading distribution on the Lamb mode amplitudes is mainly reflected by amplitude versus frequency or wavenumber. The frequencies at which the maxima and minima of the S0 or A0 mode response occur depend on the distribution of surface loading. The numerical results of simulations conducted on an infinite aluminum plate verify the theoretical prediction of not only the direction but also the distribution of applied loading. A pure S0 or A0 mode can be excited by selecting the appropriate direction and distribution at the corresponding frequency.
Balvantín, A J; Diosdado-De-la-Peña, J A; Limon-Leyva, P A; Hernández-Rodríguez, E
2018-02-01
In this work, fundamental symmetric Lamb wave S0 mode is characterized in terms of its velocity variation as function of the interfacial conditions between solid bodies in contact. Imperfect contact conditions are numerically and experimentally determined by using ultrasonic Lamb wave propagation parameters. For the study, an experimental system was used, formed by two solid aluminum rods (25.4mm in diameter) axially loading a thin aluminum plate to control contact interfacial stiffness. The axially applied load on the aluminum plate was varied from 0MPa to 10MPa. Experimental Lamb wave signals were excited on the plate through two longitudinal contact transducers (1MHz of central frequency) using a pitch-catch configuration. Numerical simulations of contact conditions and Lamb wave propagation were performed through Finite Element Analysis (FEA) in commercial software, ANSYS 15®. Simulated Lamb wave signals were generated by means of a 5 cycles tone burst signals with different frequency values. Results indicate a velocity change in both, experimental and simulated Lamb wave signals as function of the applied load. Finally, a comparison between numerical results and experimental measurements was performed obtaining a good agreement. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Sang Jun
Autonomous structural health monitoring (SHM) systems using active sensing devices have been studied extensively to diagnose the current state of aerospace, civil infrastructure and mechanical systems in near real-time and aims to eventually reduce life-cycle costs by replacing current schedule-based maintenance with condition-based maintenance. This research develops four schemes for SHM applications: (1) a simple and reliable PZT transducer self-sensing scheme; (2) a smart PZT self-diagnosis scheme; (3) an instantaneous reciprocity-based PZT diagnosis scheme; and (4) an effective PZT transducer tuning scheme. First, this research develops a PZT transducer self-sensing scheme, which is a necessary condition to accomplish a PZT transducer self-diagnosis. Main advantages of the proposed self-sensing approach are its simplicity and adaptability. The necessary hardware is only an additional self-sensing circuit which includes a minimum of electric components. With this circuit, the self-sensing parameters can be calibrated instantaneously in the presence of changing operational and environmental conditions of the system. In particular, this self-sensing scheme focuses on estimating the mechanical response in the time domain for the subsequent applications of the PZT transducer self-diagnosis and tuning with guided wave propagation. The most significant challenge of this self-sensing comes from the fact that the magnitude of the mechanical response is generally several orders of magnitude smaller than that of the input signal. The proposed self-sensing scheme fully takes advantage of the fact that any user-defined input signals can be applied to a host structure and the input waveform is known. The performance of the proposed self-sensing scheme is demonstrated by theoretical analysis, numerical simulations and various experiments. Second, this research proposes a smart PZT transducer self-diagnosis scheme based on the developed self-sensing scheme. Conventionally, the capacitance change of the PZT wafer is monitored to identify the abnormal PZT condition because the capacitance of the PZT wafer is linearly proportional to its size and also related to the bonding condition. However, temperature variation is another primary factor that affects the PZT capacitance. To ensure the reliable transducer self-diagnosis, two different self-diagnosis features are proposed to differentiate two main PZT wafer defects, i.e., PZT debonding and PZT cracking, from temperature variations and structural damages. The PZT debonding is identified using two indices based on time reversal process (TRP) without any baseline data. Also, the PZT cracking is identified by monitoring the change of the generated Lamb wave power ratio index with respect to the driving frequency. The uniqueness of this self-diagnosis scheme is that the self-diagnosis features can differentiate the PZT defects from environmental variations and structural damages. Therefore, it is expected to minimize false-alarms which are induced by operational or environmental variations as well as structural damages. The applicability of the proposed self-diagnosis scheme is verified by theoretical analysis, numerical simulations, and experimental tests. Third, a new methodology of guided wave-based PZT transducer diagnosis is developed to identify PZT transducer defects without using prior baseline data. This methodology can be applied when a number of same-size PZT transducers are attached to a target structure to form a sensor network. The advantage of the proposed technique is that abnormal PZT transducers among intact PZT transducers can be detected even when the system being monitored is subjected to varying operational and environmental conditions or changing structural conditions. To achieve this goal, the proposed diagnosis technique utilizes the linear reciprocity of guided wave propagation between a pair of surface-bonded PZT transducers. Finally, a PZT transducer tuning scheme is being developed for selective Lamb wave excitation and sensing. This is useful for structural damage detection based on Lamb wave propagation because the proper transducer size and the corresponding input frequency can be is crucial for selective Lamb wave excitation and sensing. The circular PZT response model is derived, and the energy balance is included for a better prediction of the PZT responses because the existing PZT response models do not consider any energy balance between Lamb wave modes. In addition, two calibration methods are also suggested in order to model the PZT responses more accurately by considering a bonding layer effect. (Abstract shortened by UMI.)
Tiwari, Kumar Anubhav; Raisutis, Renaldas; Mazeika, Liudas; Samaitis, Vykintas
2018-03-26
In this paper, a novel 2D analytical model based on the Huygens's principle of wave propagation is proposed in order to predict the directivity patterns of contact type ultrasonic transducers in the generation of guided waves (GWs). The developed model is able to estimate the directivity patterns at any distance, at any excitation frequency and for any configuration and shape of the transducers with prior information of phase dispersive characteristics of the guided wave modes and the behavior of transducer. This, in turn, facilitates to choose the appropriate transducer or arrays of transducers, suitable guided wave modes and excitation frequency for the nondestructive testing (NDT) and structural health monitoring (SHM) applications. The model is demonstrated for P1-type macro-fiber composite (MFC) transducer glued on a 2 mm thick aluminum (Al) alloy plate. The directivity patterns of MFC transducer in the generation of fundamental guided Lamb modes (the S0 and A0) and shear horizontal mode (the SH0) are successfully obtained at 80 kHz, 5-period excitation signal. The results are verified using 3D finite element (FE) modelling and experimental investigation. The results obtained using the proposed model shows the good agreement with those obtained using numerical simulations and experimental analysis. The calculation time using the analytical model was significantly shorter as compared to the time spent in experimental analysis and FE numerical modelling.
NASA Astrophysics Data System (ADS)
Sun, Wenxiu; Liu, Guoqiang; Xia, Hui; Xia, Zhengwu
2018-03-01
Accurate acquisition of the detection signal travel time plays a very important role in cross-hole tomography. The experimental platform of aluminum plate under the perpendicular magnetic field is established and the bilinear time-frequency analysis methods, Wigner-Ville Distribution (WVD) and the pseudo-Wigner-Ville distribution (PWVD), are applied to analyse the Lamb wave signals detected by electromagnetic acoustic transducer (EMAT). By extracting the same frequency component of the time-frequency spectrum as the excitation frequency, the travel time information can be obtained. In comparison with traditional linear time-frequency analysis method such as short-time Fourier transform (STFT), the bilinear time-frequency analysis method PWVD is more appropriate in extracting travel time and recognizing patterns of Lamb wave.
High-frequency Lamb wave device composed of MEMS structure using LiNbO3 thin film and air gap.
Kadota, Michio; Ogami, Takashi; Yamamoto, Kansho; Tochishita, Hikari; Negoro, Yasuhiro
2010-11-01
High-frequency devices operating at 3 GHz or higher are required, for instance, for future 4th generation mobile phone systems in Japan. Using a substrate with a high acoustic velocity is one method to realize a high-frequency acoustic or elastic device. A Lamb wave has a high velocity when the substrate thickness is thin. To realize a high-frequency device operating at 3 GHz or higher using a Lamb wave, a very thin (less than 0.5 μm thick) single-crystal plate must be used. It is difficult to fabricate such a very thin single crystal plate. The authors have attempted to use a c-axis orientated epitaxial LiNbO(3) thin film deposited by a chemical vapor deposition system (CVD) instead of using a thin LiNbO(3) single crystal plate. Lamb wave resonators composed of a interdigital transducer (IDT)/the LiNbO(3) film/air gap/base substrate structure like micro-electromechanical system (MEMS) transducers were fabricated. These resonators have shown a high frequency of 4.5 and 6.3 GHz, which correspond to very high acoustic velocities of 14,000 and 12,500 m/s, respectively, have excellent characteristics such as a ratio of resonant and antiresonant impedance of 52 and 38 dB and a wide band of 7.2% and 3.7%, respectively, and do not have spurious responses caused by the 0th modes of shear horizontal (SH(0)) and symmetric (S(0)) modes.
Non-contact feature detection using ultrasonic Lamb waves
Sinha, Dipen N [Los Alamos, NM
2011-06-28
Apparatus and method for non-contact ultrasonic detection of features on or within the walls of hollow pipes are described. An air-coupled, high-power ultrasonic transducer for generating guided waves in the pipe wall, and a high-sensitivity, air-coupled transducer for detecting these waves, are disposed at a distance apart and at chosen angle with respect to the surface of the pipe, either inside of or outside of the pipe. Measurements may be made in reflection or transmission modes depending on the relative position of the transducers and the pipe. Data are taken by sweeping the frequency of the incident ultrasonic waves, using a tracking narrow-band filter to reduce detected noise, and transforming the frequency domain data into the time domain using fast Fourier transformation, if required.
Non-contact ultrasonic gas flow metering using air-coupled leaky Lamb waves.
Fan, Zichuan; Jiang, Wentao; Wright, William M D
2018-04-23
This paper describes a completely non-contact ultrasonic method of gas flow metering using air-coupled leaky Lamb waves. To show proof of principle, a simplified representation of gas flow in a duct, comprising two separated thin isotropic plates with a gas flowing between them, has been modelled and investigated experimentally. An airborne compression wave emitted from an air-coupled capacitive ultrasonic transducer excited a leaky Lamb wave in the first plate in a non-contact manner. The leakage of this Lamb wave crossed the gas flow at an angle between the two plates as a compression wave, and excited a leaky Lamb wave in the second plate. An air-coupled capacitive ultrasonic transducer on the opposite side of this second plate then detected the airborne compression wave leakage from the second Lamb wave. As the gas flow shifted the wave field between the two plates, the point of Lamb wave excitation in the second plate was displaced in proportion to the gas flow rate. Two such measurements, in opposite directions, formed a completely non-contact contra-propagating Lamb wave flow meter, allowing measurement of the flow velocity between the plates. A COMSOL Multiphysics® model was used to visualize the wave fields, and accurately predicted the time differences that were then measured experimentally. Experiments using different Lamb wave frequencies and plate materials were also similarly verified. This entirely non-contact airborne approach to Lamb wave flow metering could be applied in place of clamp-on techniques in thin-walled ducts or pipes. Copyright © 2018 Elsevier B.V. All rights reserved.
Detecting Lamb waves with broadband acousto-ultrasonic signals in composite structures
NASA Technical Reports Server (NTRS)
Kautz, Harold E.
1992-01-01
Lamb waves can be produced and detected in ceramic matrix composites (CMC) and metal matrix composites (MMC) plates using the acousto-ultrasonic configuration employing broadband transducers. Experimental dispersion curves of lowest symmetric and lowest antisymmetric modes behave in a manner analogous to the graphite/polymer theoretical curves. In this study a basis has been established for analyzing Lamb wave velocities for characterizing composite plates. Lamb wave disperison curves and group velocities were correlated with variations in axial stiffness and shear stiffness in MMC and CMC. For CMCs, interfacial shear strength was also correlated with the first antisymmetric Lamb mode.
Detecting Lamb waves with broad-band acousto-ultrasonic signals in composite structures
NASA Technical Reports Server (NTRS)
Kautz, Harold E.
1992-01-01
Lamb waves can be produced and detected in ceramic matrix composites (CMC) and metal matrix composites (MMC) plates using the acousto-ultrasonic configuration employing broadband transducers. Experimental dispersion curves of lowest symmetric and antisymmetric modes behave in a manner analogous to the graphite/polymer theoretical curves. In this study a basis has been established for analyzing Lamb wave velocities for characterizing composite plates. Lamb wave dispersion curves and group velocities were correlated with variations in axial stiffness and shear stiffness in MMC and CMC. For CMC, interfacial shear strength was also correlated with the first antisymmetric Lamb mode.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belle R. Upadhyaya; J. Wesley Hines
2004-09-27
Integrity monitoring and flaw diagnostics of flat beams and tubular structures was investigated in this research task using guided acoustic signals. A piezo-sensor suite was deployed to activate and collect Lamb wave signals that propagate along metallic specimens. The dispersion curves of Lamb waves along plate and tubular structures are generated through numerical analysis. Several advanced techniques were explored to extract representative features from acoustic time series. Among them, the Hilbert-Huang transform (HHT) is a recently developed technique for the analysis of non-linear and transient signals. A moving window method was introduced to generate the local peak characters from acousticmore » time series, and a zooming window technique was developed to localize the structural flaws. The time-frequency analysis and pattern recognition techniques were combined for classifying structural defects in brass tubes. Several types of flaws in brass tubes were tested, both in the air and in water. The techniques also proved to be effective under background/process noise. A detailed theoretical analysis of Lamb wave propagation was performed and simulations were carried out using the finite element software system ABAQUS. This analytical study confirmed the behavior of the acoustic signals acquired from the experimental studies. The report presents the background the analysis of acoustic signals acquired from piezo-electric transducers for structural defect monitoring. A comparison of the use of time-frequency techniques, including the Hilbert-Huang transform, is presented. The report presents the theoretical study of Lamb wave propagation in flat beams and tubular structures, and the need for mode separation in order to effectively perform defect diagnosis. The results of an extensive experimental study of detection, location, and isolation of structural defects in flat aluminum beams and brass tubes are presented. The results of this research show the feasibility of on-line monitoring of small structural flaws by the use of transient and nonlinear acoustic signal analysis, and its implementation by the proper design of a piezo-electric transducer suite.« less
Patra, Subir; Ahmed, Hossain; Banerjee, Sourav
2018-01-18
Peridynamic based elastodynamic computation tool named Peri-elastodynamics is proposed herein to simulate the three-dimensional (3D) Lamb wave modes in materials for the first time. Peri-elastodynamics is a nonlocal meshless approach which is a scale-independent generalized technique to visualize the acoustic and ultrasonic waves in plate-like structure, micro-electro-mechanical systems (MEMS) and nanodevices for their respective characterization. In this article, the characteristics of the fundamental Lamb wave modes are simulated in a sample plate-like structure. Lamb wave modes are generated using a surface mounted piezoelectric (PZT) transducer which is actuated from the top surface. The proposed generalized Peri-elastodynamics method is not only capable of simulating two dimensional (2D) in plane wave under plane strain condition formulated previously but also capable of accurately simulating the out of plane Symmetric and Antisymmetric Lamb wave modes in plate like structures in 3D. For structural health monitoring (SHM) of plate-like structures and nondestructive evaluation (NDE) of MEMS devices, it is necessary to simulate the 3D wave-damage interaction scenarios and visualize the different wave features due to damages. Hence, in addition, to simulating the guided ultrasonic wave modes in pristine material, Lamb waves were also simulated in a damaged plate. The accuracy of the proposed technique is verified by comparing the modes generated in the plate and the mode shapes across the thickness of the plate with theoretical wave analysis.
Temperature effects in ultrasonic Lamb wave structural health monitoring systems.
Lanza di Scalea, Francesco; Salamone, Salvatore
2008-07-01
There is a need to better understand the effect of temperature changes on the response of ultrasonic guided-wave pitch-catch systems used for structural health monitoring. A model is proposed to account for all relevant temperature-dependent parameters of a pitch-catch system on an isotropic plate, including the actuator-plate and plate-sensor interactions through shear-lag behavior, the piezoelectric and dielectric permittivity properties of the transducers, and the Lamb wave dispersion properties of the substrate plate. The model is used to predict the S(0) and A(0) response spectra in aluminum plates for the temperature range of -40-+60 degrees C, which accounts for normal aircraft operations. The transducers examined are monolithic PZT-5A [PZT denotes Pb(Zr-Ti)O3] patches and flexible macrofiber composite type P1 patches. The study shows substantial changes in Lamb wave amplitude response caused solely by temperature excursions. It is also shown that, for the transducers considered, the response amplitude changes follow two opposite trends below and above ambient temperature (20 degrees C), respectively. These results can provide a basis for the compensation of temperature effects in guided-wave damage detection systems.
Giurgiutiu, Victor
2017-01-01
Piezoelectric wafer active sensors (PWAS) are commonly used for detecting Lamb waves for structural health monitoring application. However, in most applications of active sensing, the signals are of high-amplitude and easy to detect. In this article, we have shown a new avenue of using the PWAS transducer for detecting the low-amplitude fatigue-crack related acoustic emission (AE) signals. Multiphysics finite element (FE) simulations were performed with two PWAS transducers bonded to the structure. Various configurations of the sensors were studied by using the simulations. One PWAS was placed near to the fatigue-crack and the other one was placed at a certain distance from the crack. The simulated AE event was generated at the crack tip. The simulation results showed that both PWAS transducers were capable of sensing the AE signals. To validate the multiphysics simulation results, an in-situ AE-fatigue experiment was performed. Two PWAS transducers were bonded to the thin aerospace test coupon. The fatigue crack was generated in the test coupon which had produced low-amplitude acoustic waves. The low-amplitude fatigue-crack related AE signals were successfully captured by the PWAS transducers. The distance effect on the captured AE signals was also studied. It has been shown that some high-frequency contents of the AE signal have developed as they travel away from the crack. PMID:28817081
Combined distributed and concentrated transducer network for failure indication
NASA Astrophysics Data System (ADS)
Ostachowicz, Wieslaw; Wandowski, Tomasz; Malinowski, Pawel
2010-03-01
In this paper algorithm for discontinuities localisation in thin panels made of aluminium alloy is presented. Mentioned algorithm uses Lamb wave propagation methods for discontinuities localisation. Elastic waves were generated and received using piezoelectric transducers. They were arranged in concentrated arrays distributed on the specimen surface. In this way almost whole specimen could be monitored using this combined distributed-concentrated transducer network. Excited elastic waves propagate and reflect from panel boundaries and discontinuities existing in the panel. Wave reflection were registered through the piezoelectric transducers and used in signal processing algorithm. Proposed processing algorithm consists of two parts: signal filtering and extraction of obstacles location. The first part was used in order to enhance signals by removing noise from them. Second part allowed to extract features connected with wave reflections from discontinuities. Extracted features damage influence maps were a basis to create damage influence maps. Damage maps indicated intensity of elastic wave reflections which corresponds to obstacles coordinates. Described signal processing algorithms were implemented in the MATLAB environment. It should be underlined that in this work results based only on experimental signals were presented.
Selective Excitation of Lamb-Waves for Damage Detection in Composites
NASA Astrophysics Data System (ADS)
Petculescu, G.; Krishnaswamy, S.; Achenbach, J. D.
2006-03-01
Sensors based on periodic arrays of coherent piezoelectric sources (comb design) are used to selectively excite and detect Lamb waves in aluminum and AS4/3601 unidirectional carbon-epoxy plates. 110 μm PVDF film poled in the thickness direction is used as piezoelectric material. An algorithm to eliminate the effect of coupling in amplitude measurements, using individual Lamb modes excited/detected by the same transducer pair, is described. A multiple-impact test showing a decrease in amplitude and group velocity as damage progresses is used as an example.
NASA Astrophysics Data System (ADS)
Syed, Ahmed Rashid
Among the great physical challenges faced by the current front-end semiconductor equipment manufacturers is the accurate and repeatable surface temperature measurement of wafers during various fabrication steps. Close monitoring of temperature is essential in that it ensures desirable device characteristics to be reliably reproduced across various wafer lots. No where is the need to control temperature more pronounced than it is during Rapid Thermal Processing (RTP) which involves temperature ramp rates in excess of 200°C/s. This dissertation presents an elegant and practical approach to solve the wafer surface temperature estimation problem, in context of RTP, by deploying hardware that acquires the necessary data while preserving the integrity and purity of the wafer. In contrast to the widely used wafer-contacting (and hence contaminating) methods, such as bonded thermocouples, or environment sensitive schemes, such as light-pipes and infrared pyrometry, the proposed research explores the concept of utilizing Lamb (acoustic) waves to detect changes in wafer surface temperature, during RTP. Acoustic waves are transmitted to the wafer via an array of quartz rods that normally props the wafer inside an RTP chamber. These waves are generated using piezoelectric transducers affixed to the bases of the quartz rods. The group velocity of Lamb waves traversing the wafer surface undergoes a monotonic decrease with rise in wafer temperature. The correspondence of delay in phase of the received Lamb waves and the ambient temperature, along all direct paths between sending and receiving transducers, yields a psuedo real-time thermal image of the wafer. Although the custom built hardware-setup implements the above "proof-of-concept" scheme by transceiving acoustic signals at a single frequency, the real-world application will seek to enhance the data acquistion. rate (>1000 temperature measurements per seconds) by sending and receiving Lamb waves at multiple frequencies (by employing broadband quartz rod-transducer assembles). Experimental results, as predicted by prior rigorous simulations, prove that the temperature measurement accuracy obtained through several dynamic runs using the above specified approach, is better than +/-2°C. Furthermore, these results are highly repeatable and independent of wafer treatment conditions, thereby extolling the versatility and immunity of the new method from environmental conditions.
NASA Technical Reports Server (NTRS)
Prosser, W. H.; Seale, M. D.; Smith, B. T.
1997-01-01
Acoustic waves propagate in thin plates as guided or Lamb modes. The velocities of these modes are dispersive in that they depend not only on the material elastic properties and density, but also on the frequency. Accurate characterization of Lamb wave dispersion is important in many acoustic based nondestructive evaluation techniques. It is necessary for ultrasonic measurements in thin plates to determine elastic properties and for flaw detection and localization. In acoustic emission (AE) testing, if not taken into account, highly dispersive Lamb mode propagation can lead to large errors in source location. In this study, the pseudo Wigner-Ville distribution (PWVD) was used for measurement of group velocity dispersion of Lamb waves in a unidirectional graphite/epoxy (AS4/3502) laminate. The PWVD is one of a number of transforms which provide a time-frequency representation of a digitized time series. Broad band acoustic waves were generated by a pencil lead fracture (Hsu-Neilsen source) and were detected with broad band ultrasonic transducers. The arrival times for the lowest order symmetric (S(sub 0)) and antisymmetric (A(sub 0)) Lamb modes were determined from measurements of the time at which the respective peak amplitudes occurred in the PWVD. Measurements were made at several source-to-detector distances and a least squares fit used to calculate the velocity. Results are presented for propagation along, and perpendicular to, the fiber direction. Theoretical dispersion curves were also calculated and a comparison between theory and experiment demonstrates good agreement.
NASA Astrophysics Data System (ADS)
Lim, Say Ian; Liu, Yu; Soh, Chee Kiong
2012-04-01
Fatigue cracks often initiate at the weld toes of welded steel connections. Usually, these cracks cannot be identified by the naked eyes. Existing identification methods like dye-penetration test and alternating current potential drop (ACPD) may be useful for detecting fatigue cracks at the weld toes. To apply these non-destructive evaluation (NDE) techniques, the potential sites have to be accessible during inspection. Therefore, there is a need to explore other detection and monitoring techniques for fatigue cracks especially when their locations are inaccessible or cost of access is uneconomical. Electro-mechanical Impedance (EMI) and Lamb wave techniques are two fast growing techniques in the Structural Health Monitoring (SHM) community. These techniques use piezoelectric ceramics (PZT) for actuation and sensing. Since the monitoring site is only needed to be accessed once for the instrumentation of the transducers, remote monitoring is made possible. The permanent locations of these transducers also translate to having consistent measurement for monitoring. The main focus of this study is to conduct a comparative investigation on the effectiveness and efficiency of the EMI technique and the Lamb wave technique for successful fatigue crack identification and monitoring of welded steel connections using piezoelectric transducers. A laboratory-sized non-load carrying fillet weld specimen is used in this study. The specimen is subjected to cyclic tensile load and data for both techniques are acquired at stipulated intervals. It can be concluded that the EMI technique is sensitive to the crack initiation phase while the Lamb wave technique correlates well with the crack propagation phase.
Lamb Wave-Based Structural Health Monitoring on Composite Bolted Joints under Tensile Load
Yang, Bin; Xuan, Fu-Zhen; Xiang, Yanxun; Li, Dan; Zhu, Wujun; Tang, Xiaojun; Xu, Jichao; Yang, Kang; Luo, Chengqiang
2017-01-01
Online and offline monitoring of composite bolted joints under tensile load were investigated using piezoelectric transducers. The relationships between Lamb wave signals, pre-tightening force, the applied tensile load, as well as the failure modes were investigated. Results indicated that S0/A0 wave amplitudes decrease with the increasing of load. Relationships between damage features and S0/A0 mode were built based on the finite element (FE) simulation and experimental results. The possibility of application of Lamb wave-based structure health monitoring in bolted joint-like composite structures was thus achieved. PMID:28773014
NASA Astrophysics Data System (ADS)
Hasanian, Mostafa; Lissenden, Cliff J.
2017-08-01
The extraordinary sensitivity of nonlinear ultrasonic waves to the early stages of material degradation makes them excellent candidates for nondestructive material characterization. However, distinguishing weak material nonlinearity from instrumentation nonlinearity remains problematic for second harmonic generation approaches. A solution to this problem is to mix waves having different frequencies and to let their mutual interaction generate sum and difference harmonics at frequencies far from those of the instrumentation. Mixing of bulk waves and surface waves has been researched for some time, but mixing of guided waves has not yet been investigated in depth. A unique aspect of guided waves is their dispersive nature, which means we need to assure that a wave can propagate at the sum or difference frequency. A wave vector analysis is conducted that enables selection of primary waves traveling in any direction that generate phase matched secondary waves. We have tabulated many sets of primary waves and phase matched sum and difference harmonics. An example wave mode triplet of two counter-propagating collinear shear horizontal waves that interact to generate a symmetric Lamb wave at the sum frequency is simulated using finite element analysis and then laboratory experiments are conducted. The finite element simulation eliminates issues associated with instrumentation nonlinearities and signal-to-noise ratio. A straightforward subtraction method is used in the experiments to identify the material nonlinearity induced mutual interaction and show that the generated Lamb wave propagates on its own and is large enough to measure. Since the Lamb wave has different polarity than the shear horizontal waves the material nonlinearity is clearly identifiable. Thus, the mutual interactions of shear horizontal waves in plates could enable volumetric characterization of material in remote regions from transducers mounted on just one side of the plate.
Frequency steerable acoustic transducers
NASA Astrophysics Data System (ADS)
Senesi, Matteo
Structural health monitoring (SHM) is an active research area devoted to the assessment of the structural integrity of critical components of aerospace, civil and mechanical systems. Guided wave methods have been proposed for SHM of plate-like structures using permanently attached piezoelectric transducers, which generate and sense waves to evaluate the presence of damage. Effective interrogation of structural health is often facilitated by sensors and actuators with the ability to perform electronic, i.e. phased array, scanning. The objective of this research is to design an innovative directional piezoelectric transducer to be employed for the localization of broadband acoustic events, or for the generation of Lamb waves for active interrogation of structural health. The proposed Frequency Steerable Acoustic Transducers (FSATs) are characterized by a spatial arrangement of active material which leads to directional characteristics varying with frequency. Thus FSATs can be employed both for directional sensing and generation of guided waves without relying on phasing and control of a large number of channels. The analytical expression of the shape of the FSATs is obtained through a theoretical formulation for continuously distributed active material as part of a shaped piezoelectric device. The FSAT configurations analyzed in this work are a quadrilateral array and a geometry which corresponds to a spiral in the wavenumber domain. The quadrilateral array is experimentally validated, confirming the concept of frequency-dependent directionality. Its limited directivity is improved by the Wavenumber Spiral FSAT (WS-FSAT), which, instead, is characterized by a continuous frequency dependent directionality. Preliminary validations of the WS-FSAT, using a laser doppler vibrometer, are followed by the implementation of the WS-FSAT as a properly shaped piezo transducer. The prototype is first used for localization of acoustic broadband sources. Signal processing algorithms and related imaging techniques for damage location are also presented. Finally, the WS-FSAT has also been experimentally validated in generation.
Acousto-optic modulation of a photonic crystal nanocavity with Lamb waves in microwave K band
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tadesse, Semere A.; School of Physics and Astronomy, University of Minnesota, Minneapolis, Minnesota 55455; Li, Huan
2015-11-16
Integrating nanoscale electromechanical transducers and nanophotonic devices potentially can enable acousto-optic devices to reach unprecedented high frequencies and modulation efficiency. Here, we demonstrate acousto-optic modulation of a photonic crystal nanocavity using Lamb waves with frequency up to 19 GHz, reaching the microwave K band. The devices are fabricated in suspended aluminum nitride membrane. Excitation of acoustic waves is achieved with interdigital transducers with period as small as 300 nm. Confining both acoustic wave and optical wave within the thickness of the membrane leads to improved acousto-optic modulation efficiency in these devices than that obtained in previous surface acoustic wave devices. Ourmore » system demonstrates a scalable optomechanical platform where strong acousto-optic coupling between cavity-confined photons and high frequency traveling phonons can be explored.« less
Wang, Dengjiang; Zhang, Weifang; Wang, Xiangyu; Sun, Bo
2016-01-01
This study presents a novel monitoring method for hole-edge corrosion damage in plate structures based on Lamb wave tomographic imaging techniques. An experimental procedure with a cross-hole layout using 16 piezoelectric transducers (PZTs) was designed. The A0 mode of the Lamb wave was selected, which is sensitive to thickness-loss damage. The iterative algebraic reconstruction technique (ART) method was used to locate and quantify the corrosion damage at the edge of the hole. Hydrofluoric acid with a concentration of 20% was used to corrode the specimen artificially. To estimate the effectiveness of the proposed method, the real corrosion damage was compared with the predicted corrosion damage based on the tomographic method. The results show that the Lamb-wave-based tomographic method can be used to monitor the hole-edge corrosion damage accurately. PMID:28774041
Application of optical interferometry in focused acoustic field measurement
NASA Astrophysics Data System (ADS)
Wang, Yuebing; Sun, Min; Cao, Yonggang; Zhu, Jiang
2018-07-01
Optical interferometry has been successfully applied in measuring acoustic pressures in plane-wave fields and spherical-wave fields. In this paper, the "effective" refractive index for focused acoustic fields was developed, through numerical simulation and experiments, the feasibility of the optical method in measuring acoustic fields of focused transducers was proved. Compared with the results from a membrane hydrophone, it was concluded that the optical method has good spatial resolution and is suitable for detecting focused fields with fluctuant distributions. The influences of a few factors (the generated lamb wave, laser beam directivity, etc.) were analyzed, and corresponding suggestions were proposed for effective application of this technology.
Measurement of leaky Lamb wave dispersion curves with application on coating characterization
NASA Astrophysics Data System (ADS)
Lee, Yung-Chun; Cheng, Sheng Wen
2001-04-01
This paper describes a new measurement system for measuring dispersion curves of leaky Lamb waves. The measurement system is based on a focusing PVDF transducer, the defocusing measurement, the V(f,z) waveform processing method, and an image displaying technique. The measurement system is applied for the determination of thin-film elastic properties, namely Young's modulus and shear modulus, by the inversion of dispersion curves measured from a thin-film/plate configuration. Elastic constants of electro-deposited nickel layers are determined with this method.
Lu, Guangtao; Feng, Qian; Li, Yourong; Wang, Hao; Song, Gangbing
2017-01-01
During the propagation of ultrasonic waves in structures, there is usually energy loss due to ultrasound energy diffusion and dissipation. The aim of this research is to characterize the ultrasound energy diffusion that occurs due to small-size damage on an aluminum plate using piezoceramic transducers, for the future purpose of developing a damage detection algorithm. The ultrasonic energy diffusion coefficient is related to the damage distributed in the medium. Meanwhile, the ultrasonic energy dissipation coefficient is related to the inhomogeneity of the medium. Both are usually employed to describe the characteristics of ultrasound energy diffusion. The existence of multimodes of Lamb waves in metallic plate structures results in the asynchronous energy transport of different modes. The mode of Lamb waves has a great influence on ultrasound energy diffusion as a result, and thus has to be chosen appropriately. In order to study the characteristics of ultrasound energy diffusion in metallic plate structures, an experimental setup of an aluminum plate with a through-hole, whose diameter varies from 0.6 mm to 1.2 mm, is used as the test specimen with the help of piezoceramic transducers. The experimental results of two categories of damages at different locations reveal that the existence of damage changes the energy transport between the actuator and the sensor. Also, when there is only one dominate mode of Lamb wave excited in the structure, the ultrasound energy diffusion coefficient decreases approximately linearly with the diameter of the simulated damage. Meanwhile, the ultrasonic energy dissipation coefficient increases approximately linearly with the diameter of the simulated damage. However, when two or more modes of Lamb waves are excited, due to the existence of different group velocities between the different modes, the energy transport of the different modes is asynchronous, and the ultrasonic energy diffusion is not strictly linear with the size of the damage. Therefore, it is recommended that only one dominant mode of Lamb wave should be excited during the characterization process, in order to ensure that the linear relationship between the damage size and the characteristic parameters is maintained. In addition, the findings from this paper demonstrate the potential of developing future damage detection algorithms using the linear relationships between damage size and the ultrasound energy diffusion coefficient or ultrasonic energy dissipation coefficient when a single dominant mode is excited. PMID:29207530
NASA Astrophysics Data System (ADS)
Othmani, Cherif; Takali, Farid; Njeh, Anouar
2017-06-01
In this paper, the propagation of the Lamb waves in the GaAs-FGPM-AlAs sandwich plate is studied. Based on the orthogonal function, Legendre polynomial series expansion is applied along the thickness direction to obtain the Lamb dispersion curves. The convergence and accuracy of this polynomial method are discussed. In addition, the influences of the volume fraction p and thickness hFGPM of the FGPM middle layer on the Lamb dispersion curves are developed. The numerical results also show differences between the characteristics of Lamb dispersion curves in the sandwich plate for various gradient coefficients of the FGPM middle layer. In fact, if the volume fraction p increases the phase velocity will increases and the number of modes will decreases at a given frequency range. All the developments performed in this paper were implemented in Matlab software. The corresponding results presented in this work may have important applications in several industry areas and developing novel acoustic devices such as sensors, electromechanical transducers, actuators and filters.
NASA Astrophysics Data System (ADS)
De Marchi, Luca; Marzani, Alessandro; Moll, Jochen; Kudela, Paweł; Radzieński, Maciej; Ostachowicz, Wiesław
2017-07-01
The performance of Lamb wave based monitoring systems, both in terms of diagnosis time and data complexity, can be enhanced by increasing the number of transducers used to actuate simultaneously the guided waves in the inspected medium. However, in case of multiple simultaneously-operated actuators the interference among the excited wave modes within the acquired signals has to be considered for the further processing. To this aim, in this work a code division strategy based on the Warped Frequency Transform is presented. At first, the proposed procedure encodes actuation pulses using Gold sequences. Next, for each considered actuator the acquired signals are compensated from dispersion by cross correlating the warped version of the actuated and received signals. Compensated signals form the base for a final wavenumber imaging meant at emphasizing defects and or anomalies by removing incident wavefield and edge reflections. The proposed strategy is tested numerically, and validated through an experiment in which guided waves are actuated in a plate by four piezoelectric transducers operating simultaneously.
Lamb wave propagation in Z-pin reinforced co-cured composite pi-joints
NASA Astrophysics Data System (ADS)
Swenson, Eric D.; Soni, Som R.; Kapoor, Hitesh
2010-04-01
This paper presents an initial study on Lamb wave propagation characteristics in z-pin reinforced, co-cured composite pi-joints for the purposes of structural health monitoring (SHM). Pi-joint test articles were designed and created to replicate a co-cured, all composite skin-spar joint found within a typical aircraft wing structure. Because pi-joints exhibit various complex damage modes, formal studies are required if SHM systems are to be developed to monitor these types of joints for potential damage. Experiments were conducted on a undamaged (healthy) and damaged test articles where Lamb waves were excited using one lead zirconate titanate (PZT) transducer. A three-dimensional (3D) scanning laser Doppler vibrometer (LDV) was used to collect high-density scans of both the in-plane and out-of-plane velocity measurements. In the damaged test article, where delamination, matrix cracking, and fiber breakage can clearly be seen, changes in both the fundamental antisymmetric A0 and symmetric S0 Lamb wave modes are apparent. In both test articles, the effects of narrow geometry, discontinuity due to the attachment of the web, and thickness has detectable effects on Lamb wave propagation. From the comparisons between Lamb waves propagating through the undamaged and damaged test articles, it is clear that damage can be detected using Lamb waves in z-pin reinforced, co-cured composite pi-joints for this case of extensive damage.
Lamb wave tomographic imaging system for aircraft structural health assessment
NASA Astrophysics Data System (ADS)
Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.
1999-01-01
A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.
Lowe, Premesh S; Duan, Wenbo; Kanfoud, Jamil; Gan, Tat-Hean
2017-11-04
There is an increasing interest in using ultrasonic guided waves to assess the structural degradation of above-ground storage tank floors. This is a non-invasive and economically viable means of assessing structural degradation. Above-ground storage tank floors are ageing assets which need to be inspected periodically to avoid structural failure. At present, normal-stress type transducers are bonded to the tank annular chime to generate a force field in the thickness direction of the floor and excite fundamental symmetric and asymmetric Lamb modes. However, the majority of above-ground storage tanks in use have no annular chime due to a simplified design and/or have a degraded chime due to corrosion. This means that transducers cannot be mounted on the chime to assess structural health according to the present technology, and the market share of structural health monitoring of above-ground storage tank floors using ultrasonic guided wave is thus limited. Therefore, the present study investigates the potential of using the tank wall to bond the transducer instead of the tank annular chime. Both normal and shear type transducers were investigated numerically, and results were validated using a 4.1 m diameter above-ground storage tank. The study results show shear mode type transducers bonded to the tank wall can be used to assess the structural health of the above-ground tank floors using an ultrasonic guided wave. It is also shown that for the cases studied there is a 7.4 dB signal-to-noise ratio improvement at 45 kHz for the guided wave excitation on the tank wall using shear mode transducers.
Kanfoud, Jamil; Gan, Tat-Hean
2017-01-01
There is an increasing interest in using ultrasonic guided waves to assess the structural degradation of above-ground storage tank floors. This is a non-invasive and economically viable means of assessing structural degradation. Above-ground storage tank floors are ageing assets which need to be inspected periodically to avoid structural failure. At present, normal-stress type transducers are bonded to the tank annular chime to generate a force field in the thickness direction of the floor and excite fundamental symmetric and asymmetric Lamb modes. However, the majority of above-ground storage tanks in use have no annular chime due to a simplified design and/or have a degraded chime due to corrosion. This means that transducers cannot be mounted on the chime to assess structural health according to the present technology, and the market share of structural health monitoring of above-ground storage tank floors using ultrasonic guided wave is thus limited. Therefore, the present study investigates the potential of using the tank wall to bond the transducer instead of the tank annular chime. Both normal and shear type transducers were investigated numerically, and results were validated using a 4.1 m diameter above-ground storage tank. The study results show shear mode type transducers bonded to the tank wall can be used to assess the structural health of the above-ground tank floors using an ultrasonic guided wave. It is also shown that for the cases studied there is a 7.4 dB signal-to-noise ratio improvement at 45 kHz for the guided wave excitation on the tank wall using shear mode transducers. PMID:29113058
Higher order acoustoelastic Lamb wave propagation in stressed plates.
Pei, Ning; Bond, Leonard J
2016-11-01
Modeling and experiments are used to investigate Lamb wave propagation in the direction perpendicular to an applied stress. Sensitivity, in terms of changes in velocity, for both symmetrical and anti-symmetrical modes was determined. Codes were developed based on analytical expressions for waves in loaded plates and they were used to give wave dispersion curves. The experimental system used a pair of compression wave transducers on variable angle wedges, with set separation, and variable frequency tone burst excitation, on an aluminum plate 0.16 cm thick with uniaxial applied loads. The loads, which were up to 600 με, were measured using strain gages. Model results and experimental data are in good agreement. It was found that the change in Lamb wave velocity, due to the acoustoelastic effect, for the S 1 mode exhibits about ten times more sensitive, in terms of velocity change, than the traditional bulk wave measurements, and those performed using the fundamental Lamb modes. The data presented demonstrate the potential for the use of higher order Lamb modes for online industrial stress measurement in plate, and that the higher sensitivity seen offers potential for improved measurement systems.
Material and Phonon Engineering for Next Generation Acoustic Devices
NASA Astrophysics Data System (ADS)
Kuo, Nai-Kuei
This thesis presents the theoretical and experimental work related to micromachining of low intrinsic loss sapphire and phononic crystals for engineering new classes of electroacoustic devices for frequency control applications. For the first time, a low loss sapphire suspended membrane was fabricated and utilized to form the main body of a piezoelectric lateral overtone bulk acoustic resonator (LOBAR). Since the metalized piezoelectric transducer area in a LOBAR is only a small fraction of the overall resonant cavity (made out of sapphire), high quality factor (Q) overtones are attained. The experiment confirms the low intrinsic mechanical loss of the transferred sapphire thin film, and the resonators exhibit the highest Q of 5,440 at 2.8 GHz ( f·Q of 1.53.1013 Hz). This is also the highest f·Q demonstrated for aluminum-nitride-(AIN)-based Lamb wave devices to date. Beyond demonstrating a low loss device, this experimental work has laid the foundation for the future development of new micromechanical devices based on a high Q, high hardness and chemically resilient material. The search for alternative ways to more efficiently perform frequency control functionalities lead to the exploration of Phononic Crystal (PnC) structures in AIN thin films. Four unit cell designs were theoretically and experimentally investigated to explore the behavior of phononic bandgaps (PBGs) in the ultra high frequency (UHF) range: (i) the conventional square lattice with circular air scatterer, (ii) the inverse acoustic bandgap (IABG) structure, (iii) the fractal PnC, and (iv) the X-shaped PnC. Each unit cell has its unique frequency characteristic that was exploited to synthesize either cavity resonators or improve the performance of acoustic delay lines. The PBGs operate in the range of 770 MHz to 1 GHz and exhibit a maximum acoustic rejection of 40 dB. AIN Lamb wave transducers (LWTs) were employed for the experimental demonstration of the PBGs and cavity resonances. Ultra-wide bandwidth (˜10%) was achieved by implementing slanted finger transducers (SFIT) in thin film AIN. The impulse response and coupling of modes (COM) models commonly used for surface acoustic wave (SAW) devices were developed to design the operating frequency and bandwidth of the LWTs. These techniques enabled access to fast frequency solutions (impulse response method) and good pass-band ripple estimation (COM) for any piezoelectric Lamb-wave based device. The conventional and IABG unit cell designs were explored for the making of cavity resonators. A PnC cavity made with conventional design exhibits a Q of 675 at 665 MHz. Despite the low Q, its value is very high when the volume of the cavity is taken into account ( Q per unit volume of 3.1017/m3). In order to understand the limited value of Q a detailed finite element analysis is performed to unveil its dependence on the specific design of the transducer. The capabilities of the X-shaped PnCs were harvested for synthesizing a method to suppress the sidelobe response of an AIN Lamb wave (SFIT) delay line. 10 dB of sidelobe magnitude reduction was attained while leaving the pass-band unaltered. Although at a very preliminary stage, the theoretical and experimental work on AIN PnC has demonstrated that new acoustic capabilities are enabled by these metamaterials. Future electroacoustic devices that perform frequency control functions in a compact and low loss fashion can now be envisioned.
Micromachined capacitive ultrasonic immersion transducer array
NASA Astrophysics Data System (ADS)
Jin, Xuecheng
Capacitive micromachined ultrasonic transducers (cMUTs) have emerged as an attractive alternative to conventional piezoelectric ultrasonic transducers. They offer performance advantages of wide bandwidth and sensitivity that have heretofore been attainable. In addition, micromachining technology, which has benefited from the fast-growing microelectronics industry, enables cMUT array fabrication and electronics integration. This thesis describes the design and fabrication of micromachined capacitive ultrasonic immersion transducer arrays. The basic transducer electrical equivalent circuit is derived from Mason's theory. The effects of Lamb waves and Stoneley waves on cross coupling and acoustic losses are discussed. Electrical parasitics such as series resistance and shunt capacitance are also included in the model of the transducer. Transducer fabrication technology is systematically studied. Device dimension control in both vertical and horizontal directions, process alternatives and variations in membrane formation, via etch and cavity sealing, and metalization as well as their impact on transducer performance are summarized. Both 64 and 128 element 1-D array transducers are fabricated. Transducers are characterized in terms of electrical input impedance, bandwidth, sensitivity, dynamic range, impulse response and angular response, and their performance is compared with theoretical simulation. Various schemes for cross coupling reduction is analyzed, implemented, and verified with both experiments and theory. Preliminary results of immersion imaging are presented using 64 elements 1-D array transducers for active source imaging.
On selection of primary modes for generation of strong internally resonant second harmonics in plate
NASA Astrophysics Data System (ADS)
Liu, Yang; Chillara, Vamshi Krishna; Lissenden, Cliff J.
2013-09-01
The selection of primary shear-horizontal (SH) and Rayleigh-Lamb (RL) ultrasonic wave modes that generate cumulative second harmonics in homogeneous isotropic plates is analyzed by theoretical modeling. Selection criteria include: internal resonance (synchronism and nonzero power flux), group velocity matching, and excitability/receivability. The power flux, group velocity matching, and excitability are tabulated for the SH and RL internal resonance points. The analysis indicates that SH waves can generate cumulative symmetric RL secondary wave fields. Laboratory experiments on aluminum plates demonstrate that excitation of the SH3 primary mode generates the s4 secondary RL mode and that the secondary wave field amplitude increases linearly with propagation distance. Simple magnetostrictive transducers were used to excite the primary SH wave and to receive the SH and RL wave signals. Reception of these wave modes having orthogonal polarizations was achieved by simply reorienting the electrical coil. The experiment was complicated by the presence of a nonplanar primary wavefront, however finite element simulations were able to clarify the experimental results.
Spiral-shaped piezoelectric sensors for Lamb waves direction of arrival (DoA) estimation
NASA Astrophysics Data System (ADS)
De Marchi, L.; Testoni, N.; Marzani, A.
2018-04-01
A novel strategy to design piezoelectric sensors suited for direction of arrival (DoA) estimation of incoming Lamb waves is presented in this work. The designed sensor is composed by two piezoelectric patches (P1, P2) bonded on the structure to be inspected. In particular, by exploiting the Radon transform, the proposed procedure computes the shape of P2 given the shape of P1 so that the difference in time of arrival (DToA) of the Lamb waves at the two patches is linearly related to the DoA while being agnostic of the waveguide dispersion curves. With a dedicated processing procedure, the waveforms acquired from the two electrodes and digitized can be used to retrieve the DoA information. Numerical and experimental results show that DoA estimation performed by means of the proposed shaped transducers is extremely robust.
Research on a Lamb Wave and Particle Filter-Based On-Line Crack Propagation Prognosis Method.
Chen, Jian; Yuan, Shenfang; Qiu, Lei; Cai, Jian; Yang, Weibo
2016-03-03
Prognostics and health management techniques have drawn widespread attention due to their ability to facilitate maintenance activities based on need. On-line prognosis of fatigue crack propagation can offer information for optimizing operation and maintenance strategies in real-time. This paper proposes a Lamb wave-particle filter (LW-PF)-based method for on-line prognosis of fatigue crack propagation which takes advantages of the possibility of on-line monitoring to evaluate the actual crack length and uses a particle filter to deal with the crack evolution and monitoring uncertainties. The piezoelectric transducers (PZTs)-based active Lamb wave method is adopted for on-line crack monitoring. The state space model relating to crack propagation is established by the data-driven and finite element methods. Fatigue experiments performed on hole-edge crack specimens have validated the advantages of the proposed method.
Fatigue disbonding analysis of wide composite panels by means of Lamb waves
NASA Astrophysics Data System (ADS)
Michalcová, Lenka; Rechcígel, Lukáš; Bělský, Petr; Kucharský, Pavel
2018-03-01
Guided wave-based monitoring of composite structures plays an important role in the area of structural health monitoring (SHM) of aerospace structures. Adhesively bonded joints have not yet fulfilled current airworthiness requirements; hence, assemblies of carbon fibre-reinforced parts still require mechanical fasteners, and a verified SHM method with reliable disbonding/delamination detection and propagation assessment is needed. This study investigated the disbonding/delamination propagation in adhesively bonded panels using Lamb waves during fatigue tests. Analyses focused on the proper frequency and mode selection, sensor placement and selection of parameter sensitive to the growth of disbonding areas. Piezoelectric transducers placed across the bonded area were used as actuators and sensors. Lamb wave propagation was investigated considering the actual shape of the crack front and the mode of the crack propagation. The actual cracked area was determined by ultrasonic A-scans. A correlation between the crack propagation rate and the A0 mode velocity was found.
Multi Reflection of Lamb Wave Emission in an Acoustic Waveguide Sensor
Schmitt, Martin; Olfert, Sergei; Rautenberg, Jens; Lindner, Gerhard; Henning, Bernd; Reindl, Leonhard Michael
2013-01-01
Recently, an acoustic waveguide sensor based on multiple mode conversion of surface acoustic waves at the solid—liquid interfaces has been introduced for the concentration measurement of binary and ternary mixtures, liquid level sensing, investigation of spatial inhomogenities or bubble detection. In this contribution the sound wave propagation within this acoustic waveguide sensor is visualized by Schlieren imaging for continuous and burst operation the first time. In the acoustic waveguide the antisymmetrical zero order Lamb wave mode is excited by a single phase transducer of 1 MHz on thin glass plates of 1 mm thickness. By contact to the investigated liquid Lamb waves propagating on the first plate emit pressure waves into the adjacent liquid, which excites Lamb waves on the second plate, what again causes pressure waves traveling inside the liquid back to the first plate and so on. The Schlieren images prove this multi reflection within the acoustic waveguide, which confirms former considerations and calculations based on the receiver signal. With this knowledge the sensor concepts with the acoustic waveguide sensor can be interpreted in a better manner. PMID:23447010
Multi reflection of Lamb wave emission in an acoustic waveguide sensor.
Schmitt, Martin; Olfert, Sergei; Rautenberg, Jens; Lindner, Gerhard; Henning, Bernd; Reindl, Leonhard Michael
2013-02-27
Recently, an acoustic waveguide sensor based on multiple mode conversion of surface acoustic waves at the solid-liquid interfaces has been introduced for the concentration measurement of binary and ternary mixtures, liquid level sensing, investigation of spatial inhomogenities or bubble detection. In this contribution the sound wave propagation within this acoustic waveguide sensor is visualized by Schlieren imaging for continuous and burst operation the first time. In the acoustic waveguide the antisymmetrical zero order Lamb wave mode is excited by a single phase transducer of 1 MHz on thin glass plates of 1 mm thickness. By contact to the investigated liquid Lamb waves propagating on the first plate emit pressure waves into the adjacent liquid, which excites Lamb waves on the second plate, what again causes pressure waves traveling inside the liquid back to the first plate and so on. The Schlieren images prove this multi reflection within the acoustic waveguide, which confirms former considerations and calculations based on the receiver signal. With this knowledge the sensor concepts with the acoustic waveguide sensor can be interpreted in a better manner.
NASA Astrophysics Data System (ADS)
Pieczonka, Łukasz; Ambroziński, Łukasz; Staszewski, Wiesław J.; Barnoncel, David; Pérès, Patrick
2017-12-01
This paper introduces damage identification approach based on guided ultrasonic waves and 3D laser Doppler vibrometry. The method is based on the fact that the symmetric and antisymmetric Lamb wave modes differ in amplitude of the in-plane and out-of-plane vibrations. Moreover, the modes differ also in group velocities and normally they are well separated in time. For a given time window both modes can occur simultaneously only close to the wave source or to a defect that leads to mode conversion. By making the comparison between the in-plane and out-of-plane wave vector components the detection of mode conversion is possible, allowing for superior and reliable damage detection. Experimental verification of the proposed damage identification procedure is performed on fuel tank elements of Reusable Launch Vehicles designed for space exploration. Lamb waves are excited using low-profile, surface-bonded piezoceramic transducers and 3D scanning laser Doppler vibrometer is used to characterize the Lamb wave propagation field. The paper presents theoretical background of the proposed damage identification technique as well as experimental arrangements and results.
NASA Astrophysics Data System (ADS)
Harb, M. S.; Yuan, F. G.
2015-03-01
Conventional ultrasound inspection has been a standard non-destructive testing method for providing an in-service evaluation and noninvasive means of probing the interior of a structure. In particular, measurement of the propagation characteristics of Lamb waves allows inspection of plates that are typical components in aerospace industry. A rapid, complete non-contact hybrid approach for excitation and detection of Lamb waves is presented and applied for non-destructive evaluation of composites. An air-coupled transducer (ACT) excites ultrasonic waves on the surface of a composite plate, generating different propagating Lamb wave modes and a laser Doppler vibrometer (LDV) is used to measure the out-of-plane velocity of the plate. This technology, based on direct waveform imaging, focuses on measuring dispersive curves for A0 mode in a composite laminate and its anisotropy. A two-dimensional fast Fourier transform (2D-FFT) is applied to out-of-plane velocity data captured experimentally using LDV to go from the time-spatial domain to frequency-wavenumber domain. The result is a 2D array of amplitudes at discrete frequencies and wavenumbers for A0 mode in a given propagation direction along the composite. The peak values of the curve are then used to construct frequency wavenumber and phase velocity dispersion curves, which are also obtained directly using Snell's law and the incident angle of the excited ultrasonic waves. A high resolution and strong correlation between numerical and experimental results are observed for dispersive curves with Snell's law method in comparison to 2D-FFT method. Dispersion curves as well as velocity curves for the composite plate along different directions of wave propagation are measured. The visual read-out of the dispersion curves at different propagation directions as well as the phase velocity curves provide profiling and measurements of the composite anisotropy. The results proved a high sensitivity of the air-coupled and laser ultrasound technique in non-contact characterization of Lamb wave dispersion and material anisotropy of composite plates using simple Snell's law method.
Symmetry properties of second harmonics generated by antisymmetric Lamb waves
NASA Astrophysics Data System (ADS)
Zhu, Wujun; Xiang, Yanxun; Liu, Chang-Jun; Deng, Mingxi; Xuan, Fu-Zhen
2018-03-01
Symmetry properties of second harmonics generated by antisymmetric primary Lamb waves are systematically studied in this work. In theory, the acoustic field of second harmonic Lamb waves is obtained by using the perturbation approximation and normal modal method, and the energy flux transfer from the primary Lamb waves to second harmonics is mainly explored. Symmetry analyses indicate that either the symmetric or antisymmetric Lamb waves can merely generate the symmetric second harmonics. Finite element simulations are performed on the nonlinear Lamb wave propagation of the antisymmetric A0 mode in the low frequency region. The signals of the second harmonics and the symmetric second harmonic s0 mode are found to be exactly equivalent in the time domain. The relative acoustic nonlinearity parameter A2/A12 oscillates with the propagation distance, and the oscillation amplitude and spatial period are well consistent with the theoretical prediction of the A0-s0 mode pair, which means that only the second harmonic s0 mode is generated by the antisymmetric primary A0 mode. Experiments are further conducted to examine the cumulative generation of symmetric second harmonics for the antisymmetric-symmetric mode pair A3-s6. Results show that A2/A12 increases linearly with the propagation distance, which means that the symmetric second harmonic s6 mode is generated cumulatively by the antisymmetric primary A3 mode. The present investigation systematically corroborates the proposed theory that only symmetric second harmonics can be generated accompanying the propagation of antisymmetric primary Lamb waves in a plate.
NASA Astrophysics Data System (ADS)
Wan, Xiang; Tse, Peter W.; Zhang, Xuhui; Xu, Guanghua; Zhang, Qing; Fan, Hongwei; Mao, Qinghua; Dong, Ming; Wang, Chuanwei; Ma, Hongwei
2018-04-01
Under the discipline of nonlinear ultrasonics, in addition to second harmonic generation, static component generation is another frequently used nonlinear ultrasonic behavior in non-destructive testing (NDT) and structural health monitoring (SHM) communities. However, most previous studies on static component generation are mainly based on using longitudinal waves. It is desirable to extend static component generation from primary longitudinal waves to primary Lamb waves. In this paper, static component generation from the primary Lamb waves is studied. Two major issues are numerically investigated. First, the mode of static displacement component generated from different primary Lamb wave modes is identified. Second, cumulative effect of static displacement component from different primary Lamb wave modes is also discussed. Our study results show that the static component wave packets generated from the primary S0, A0 and S1 modes share the almost same group velocity equal to the phase velocity of S0 mode tending to zero frequency c plate . The finding indicates that whether the primary mode is S0, A0 or S1, the static components generated from these primary modes always share the nature of S0 mode. This conclusion is also verified by the displacement filed of these static components that the horizontal displacement field is almost uniform and the vertical displacement filed is antisymmetric across the thickness of the plate. The uniform distribution of horizontal displacement filed enables the static component, regardless of the primary Lamb modes, to be a promising technique for evaluating microstructural damages buried in the interior of a structure. Our study also illustrates that the static components are cumulative regardless of whether the phase velocity of the primary and secondary waves is matched or not. This observation indicates that the static component overcomes the limitations of the traditional nonlinear Lamb waves satisfying phase velocity matching condition to achieve cumulative second harmonic generation. This nature also enables the primary Lamb waves excited at a low center frequency to generate static component used for inspecting large-scale structures with micro-scale damages.
Design and characterization of an ultrasonic lamb-wave power delivery system.
Kural, Aleksander; Pullin, Rhys; Holford, Karen; Lees, Jonathan; Naylon, Jack; Paget, Christophe; Featherston, Carol
2013-06-01
In this paper, a novel design for an ultrasonic power transmission system designed for use in aircraft structural monitoring systems is described. The prototype system uses ultrasonic Lamb waves to carry energy along plates, such as those used in aircraft structures, and commercially available piezoelectric patch transducers as the transmitter and receiver. This sets it apart from other acoustic power transmission systems reported to date. The optimum configuration transmitted 12.7 mW of power across a distance of 54 cm in a 1.5-mm-thick aluminum plate, while being driven by a 20-Vpp, 35-kHz sinusoidal electric signal. This is in the same order of magnitude as the power required by the wireless sensors nodes of a structural health monitoring system currently being developed by Cardiff University and its partners. Thus, the power transmission system can be considered a viable component of the power source combination considered for the sensor nodes, which will also include vibration and thermal energy harvesting. The paper describes the design and optimization of the transmission and reception circuits with the use of inductive compensation. The use of laser vibrometry to characterize the transducers and to understand the signal propagation between them is also reported.
Dispersion of Lamb waves in a honeycomb composite sandwich panel.
Baid, Harsh; Schaal, Christoph; Samajder, Himadri; Mal, Ajit
2015-02-01
Composite materials are increasingly being used in advanced aircraft and aerospace structures. Despite their many advantages, composites are often susceptible to hidden damages that may occur during manufacturing and/or service of the structure. Therefore, safe operation of composite structures requires careful monitoring of the initiation and growth of such defects. Ultrasonic methods using guided waves offer a reliable and cost effective method for defects monitoring in advanced structures due to their long propagation range and their sensitivity to defects in their propagation path. In this paper, some of the useful properties of guided Lamb type waves are investigated, using analytical, numerical and experimental methods, in an effort to provide the knowledge base required for the development of viable structural health monitoring systems for composite structures. The laboratory experiments involve a pitch-catch method in which a pair of movable transducers is placed on the outside surface of the structure for generating and recording the wave signals. The specific cases considered include an aluminum plate, a woven composite laminate and an aluminum honeycomb sandwich panel. The agreement between experimental, numerical and theoretical results are shown to be excellent in certain frequency ranges, providing a guidance for the design of effective inspection systems. Copyright © 2014 Elsevier B.V. All rights reserved.
García-Gómez, Joaquín; Rosa-Zurera, Manuel; Romero-Camacho, Antonio; Jiménez-Garrido, Jesús Antonio; García-Benavides, Víctor
2018-01-01
Pipeline inspection is a topic of particular interest to the companies. Especially important is the defect sizing, which allows them to avoid subsequent costly repairs in their equipment. A solution for this issue is using ultrasonic waves sensed through Electro-Magnetic Acoustic Transducer (EMAT) actuators. The main advantage of this technology is the absence of the need to have direct contact with the surface of the material under investigation, which must be a conductive one. Specifically interesting is the meander-line-coil based Lamb wave generation, since the directivity of the waves allows a study based in the circumferential wrap-around received signal. However, the variety of defect sizes changes the behavior of the signal when it passes through the pipeline. Because of that, it is necessary to apply advanced techniques based on Smart Sound Processing (SSP). These methods involve extracting useful information from the signals sensed with EMAT at different frequencies to obtain nonlinear estimations of the depth of the defect, and to select the features that better estimate the profile of the pipeline. The proposed technique has been tested using both simulated and real signals in steel pipelines, obtaining good results in terms of Root Mean Square Error (RMSE). PMID:29518927
Guided Wave Sensing In a Carbon Steel Pipe Using a Laser Vibrometer System
NASA Astrophysics Data System (ADS)
Ruíz Toledo, Abelardo; Salazar Soler, Jordi; Chávez Domínguez, Juan Antonio; García Hernández, Miguel Jesús; Turó Peroy, Antoni
2010-05-01
Non-Destructive Evaluation (NDE) techniques have achieved a great development during the last decades as a valuable tool for material characterization, manufacturing control and structural integrity tests. Among these tools, the guided wave technology has been rapidly extended because it reduces inspection time and costs compared to the ordinary point by point testing in large structures, as well as because of the possibility of inspecting under insulation and coating conditions. This fast development has motivated the creation of several inspection and material characterization systems including different technologies which can be combined with this technique. Different measurements systems based on laser techniques have been presented in order to inspect pipes, plates and diverse structures. Many of them are experimental systems of high cost and complexity which combine the employment of a laser for generation of waves in the structure and an interferometer for detection. Some of them employ air-coupled ultrasound generation transducers, with high losses in air and which demand high energy for exciting waves in materials of high stiffness. The combined employment of a commercial vibrometer system for Lamb wave sensing in plates has been successfully shown in the literature. In this paper we present a measurement system based on the combined employment of a piezoelectric wedge transducer and a laser vibrometer to sense guided acoustic waves in carbon steel pipes. The measurement system here presented is mainly compounded of an angular wedge transducer, employed to generate the guided wave and a commercial laser vibrometer used in the detection process. The wedge transducer is excited by means of a signal function generator whose output signal has been amplified with a power signal amplifier. A high precision positioning system is employed to place the laser beam at different points through the pipe surface. The signal detected by the laser vibrometer system is amplified with a signal amplifier and then it is displayed in a digital storage oscilloscope. This set-up offers the possibility of analyzing in a simpler way the wave propagation and the material evaluation in pipes of certain wall thickness. The material characterization considering distinct wave propagation modes can be easily achieved, changing the different incident angles of the wedge piezoelectric probe and their combined employment with several driving signals. Moreover, this experimental sensing system offers other possibilities of inspecting and analyzing the wave propagation in some features (bends, flange joints, welds,…) of the pipe surface which cause very large reflections and mode conversions and which in practice limits the inspection range when are inspected with conventional receiving transducer arrangements.
Quantitative damage imaging using Lamb wave diffraction tomography
NASA Astrophysics Data System (ADS)
Zhang, Hai-Yan; Ruan, Min; Zhu, Wen-Fa; Chai, Xiao-Dong
2016-12-01
In this paper, we investigate the diffraction tomography for quantitative imaging damages of partly through-thickness holes with various shapes in isotropic plates by using converted and non-converted scattered Lamb waves generated numerically. Finite element simulations are carried out to provide the scattered wave data. The validity of the finite element model is confirmed by the comparison of scattering directivity pattern (SDP) of circle blind hole damage between the finite element simulations and the analytical results. The imaging method is based on a theoretical relation between the one-dimensional (1D) Fourier transform of the scattered projection and two-dimensional (2D) spatial Fourier transform of the scattering object. A quantitative image of the damage is obtained by carrying out the 2D inverse Fourier transform of the scattering object. The proposed approach employs a circle transducer network containing forward and backward projections, which lead to so-called transmission mode (TMDT) and reflection mode diffraction tomography (RMDT), respectively. The reconstructed results of the two projections for a non-converted S0 scattered mode are investigated to illuminate the influence of the scattering field data. The results show that Lamb wave diffraction tomography using the combination of TMDT and RMDT improves the imaging effect compared with by using only the TMDT or RMDT. The scattered data of the converted A0 mode are also used to assess the performance of the diffraction tomography method. It is found that the circle and elliptical shaped damages can still be reasonably identified from the reconstructed images while the reconstructed results of other complex shaped damages like crisscross rectangles and racecourse are relatively poor. Project supported by the National Natural Science Foundation of China (Grant Nos. 11474195, 11274226, 11674214, and 51478258).
Crispo, M; Vilariño, M; dos Santos-Neto, P C; Núñez-Olivera, R; Cuadro, F; Barrera, N; Mulet, A P; Nguyen, T H; Anegón, I; Menchaca, A
2015-02-01
Lentiviral technology has been recently proposed to generate transgenic farm animals more efficiently and easier than traditional techniques. The objective was to evaluate several parameters of lambs obtained by lentiviral transgenesis in comparison with non-transgenic counterparts. In vitro produced embryos were microinjected (TG group) at two-cell stage with a lentiviral construct containing enhanced green fluorescent protein (eGFP) gene, while embryos produced by in vitro fertilization (IVF group) or intrauterine insemination (IUI group) were not microinjected. Microinjection technique efficiently generated eight-cell transgenic embryos (97.4%; 114/117). Development rate on day 5 after fertilization was similar for TG (39.3%, 46/117) and IVF embryos (39.6%, 44/111). Pregnancy rate was detected in 50.0% (6/12) of recipient ewes with TG embryos, in 46.7% (7/15) with IVF embryos, and in 65.0% (13/20) of IUI ewes (P = NS). Nine lambs were born in TG group, six lambs in IVF group, and 16 lambs in IUI group. All TG lambs (9/9) were GFP positive to real-time PCR and eight (88.9%) showed a strong and evident GFP expression in mucosae, eyes and keratin tissues. Fetal growth monitored every 15 day by ultrasonography did not show significant differences. Transgenic lambs neither differ in morphometric variables in comparison with non transgenic IVF lambs within 3 months after birth. Transmission of the transgene to the progeny was observed in green fluorescent embryos produced by IVF using semen from the TG founder lambs. In conclusion, this study demonstrates the high efficiency of lentiviral technology to produce transgenic sheep, with no clinic differences in comparison with non transgenic lambs.
Nondestructive evaluation of helicopter rotor blades using guided Lamb modes.
Chakrapani, Sunil Kishore; Barnard, Daniel; Dayal, Vinay
2014-03-01
This paper presents an application for turning and direct modes in a complex composite laminate structure. The propagation and interaction of turning modes and fundamental Lamb modes are investigated in the skin, spar and web sections of a helicopter rotor blade. Finite element models were used to understand the various mode conversions at geometric discontinuities such as web-spar joints. Experimental investigation was carried out with the help of air coupled ultrasonic transducers. The turning and direct modes were confirmed with the help of particle displacements and velocities. Experimental B-Scans were performed on damaged and undamaged samples for qualitative and quantitative assessment of the structure. A strong correlation between the numerical and experimental results was observed and reported. Copyright © 2013 Elsevier B.V. All rights reserved.
Micromachined ultrasonic transducers for air-coupled nondestructive evaluation
NASA Astrophysics Data System (ADS)
Hansen, Sean T.; Degertekin, F. Levent; Khuri-Yakub, Butrus T.
1999-01-01
Conventional methods of ultrasonic non-destructive evaluation (NDE) use liquids to couple sound waves into the test samples. This either requires immersion of the parts to be examined or the use of complex and bulky water squirting systems that must be scanned over the structure. Air-coupled ultrasonic systems eliminate these requirements if the losses at air-solid interfaces are tolerable. Micromachined capacitive ultrasonic transducers (cMUTs) have been shown to have more than 100 dB dynamic range when used in the bistatic transmission mode. In this paper, we present results of a pitch-catch transmission system using cMUTs that achieves a 103 dB dynamic range. Each transducer consists of 10,000 silicon nitride membranes of 100 micrometers diameter connected in parallel. This geometry result in transducers with a resonant frequency around 2.3 MHz. These transducers can be used in transmission experiments at normal incident to the sample or to excite and detect guided waves in aluminum and composite plates. In this paper we present ultrasonic defect detection results from both through transmission and guided Lamb wave experiments in aluminum and composite plates, such as those used in aircraft.
2015-05-01
fatigue an induced ultrasonic elastic vibration (via piezoelectric transducers [ PZTs ]) propagates through the dogbone specimen. A receiver PZT picks up...inspection of fatigue crack growth in aluminum 7075-T6 dogbone specimens. Acellent Technologies, Inc., is supporting this project through providing...January 2015. 15. SUBJECT TERMS structural health monitoring, probabilistics, fatigue damage, guided waves, Lamb waves 16. SECURITY CLASSIFICATION OF
In Situ Estimation of Applied Biaxial Loads with Lamb Waves (Preprint)
2012-07-01
be correct. IV. EXPERIMENTS AND RESULTS Fatigue tests were conducted for an array of six surface-bonded PZT transducers permanently attached to...because of their cumulative effects on the fatigue life of the structures. Waves propagating between array elements are directly affected by applied loads...their cumulative effects on the fatigue life of the structures. Waves propagating between array elements are directly affected by applied loads
Guided ultrasonic wave beam skew in silicon wafers
NASA Astrophysics Data System (ADS)
Pizzolato, Marco; Masserey, Bernard; Robyr, Jean-Luc; Fromme, Paul
2018-04-01
In the photovoltaic industry, monocrystalline silicon wafers are employed for solar cells with high conversion efficiency. Micro-cracks induced by the cutting process in the thin wafers can lead to brittle wafer fracture. Guided ultrasonic waves would offer an efficient methodology for the in-process non-destructive testing of wafers to assess micro-crack density. The material anisotropy of the monocrystalline silicon leads to variations of the guided wave characteristics, depending on the propagation direction relative to the crystal orientation. Selective guided ultrasonic wave excitation was achieved using a contact piezoelectric transducer with custom-made wedges for the A0 and S0 Lamb wave modes and a transducer holder to achieve controlled contact pressure and orientation. The out-of-plane component of the guided wave propagation was measured using a non-contact laser interferometer. The phase slowness (velocity) of the two fundamental Lamb wave modes was measured experimentally for varying propagation directions relative to the crystal orientation and found to match theoretical predictions. Significant wave beam skew was observed experimentally, especially for the S0 mode, and investigated from 3D finite element simulations. Good agreement was found with the theoretical predictions based on nominal material properties of the silicon wafer. The important contribution of guided wave beam skewing effects for the non-destructive testing of silicon wafers was demonstrated.
77 FR 69506 - Exelon Generation Company, LLC., Oyster Creek Nuclear Generating Station; Exemption
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-19
... INFORMATION CONTACT: John G. Lamb, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone 301-415-3100, email: John.Lamb@nrc.gov . SUPPLEMENTARY INFORMATION: On...
NASA Astrophysics Data System (ADS)
Amory, V.; Lhémery, A.
2008-02-01
Inspection of irregular components is problematical: maladjustment of transducer shoes to surfaces causes aberrations. Flexible phased-arrays (FPAs) designed at CEA LIST to maximize contact are driven by adapted delay laws to compensate for irregularities. Optimizing FPA requires simulation tools. The behavior of one element computed by FEM is observed at the surface and its radiation experimentally validated. Efforts for one element prevent from simulating a FPA by FEM. A model is proposed where each element behaves as nonuniform source of stresses. Exact and asymptotic formulas for Lamb problem are used as convolution kernels for longitudinal, transverse and head waves; the latter is of primary importance for angle-T-beam inspections.
Lateral acoustic wave resonator comprising a suspended membrane of low damping resonator material
Olsson, Roy H.; El-Kady; , Ihab F.; Ziaei-Moayyed, Maryam; Branch; , Darren W.; Su; Mehmet F.,; Reinke; Charles M.,
2013-09-03
A very high-Q, low insertion loss resonator can be achieved by storing many overtone cycles of a lateral acoustic wave (i.e., Lamb wave) in a lithographically defined suspended membrane comprising a low damping resonator material, such as silicon carbide. The high-Q resonator can sets up a Fabry-Perot cavity in a low-damping resonator material using high-reflectivity acoustic end mirrors, which can comprise phononic crystals. The lateral overtone acoustic wave resonator can be electrically transduced by piezoelectric couplers. The resonator Q can be increased without increasing the impedance or insertion loss by storing many cycles or wavelengths in the high-Q resonator material, with much lower damping than the piezoelectric transducer material.
USDA-ARS?s Scientific Manuscript database
Ewe productivity (i.e., total numbers or weight of lamb weaned ÷ number of breeding ewes) is a key indicator of lamb production efficiency. This second-generation study compared various measures of ewe productivity and ewe and lamb performance in an extensive rangeland production system of ewes of 3...
NASA Astrophysics Data System (ADS)
Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei; Sohn, Hoon; Lim, Hyung Jin
2018-01-01
This paper presents experimental and theoretical analyses of the second harmonic generation due to non-linear interaction of Lamb waves with a fatigue crack. Three-dimensional (3D) finite element (FE) simulations and experimental studies are carried out to provide physical insight into the mechanism of second harmonic generation. The results demonstrate that the 3D FE simulations can provide a reasonable prediction on the second harmonic generated due to the contact nonlinearity at the fatigue crack. The effect of the wave modes on the second harmonic generation is also investigated in detail. It is found that the magnitude of the second harmonic induced by the interaction of the fundamental symmetric mode (S0) of Lamb wave with the fatigue crack is much higher than that by the fundamental anti-symmetric mode (A0) of Lamb wave. In addition, a series of parametric studies using 3D FE simulations are conducted to investigate the effect of the fatigue crack length to incident wave wavelength ratio, and the influence of the excitation frequency on the second harmonic generation. The outcomes show that the magnitude and directivity pattern of the generated second harmonic depend on the fatigue crack length to incident wave wavelength ratio as well as the ratio of S0 to A0 incident Lamb wave amplitude. In summary, the findings of this study can further advance the use of second harmonic generation in damage detection.
Ultrasonic flaw detection in a monorail box beam
NASA Astrophysics Data System (ADS)
Zheng, Peng; Greve, David W.; Oppenheim, Irving J.
2009-03-01
A steel box beam in a monorail application is constructed with an epoxy grout wearing surface, precluding visual inspection of its top flange. This paper describes a sequence of experimental research tasks to develop an ultrasonic system to detect flaws (such as fatigue cracks) in that flange, and the results of a field test to demonstrate system performance. The problem is constrained by the fact that the flange is exposed only along its longitudinal edges, and by the fact that permanent installation of transducers at close spacing was deemed to be impractical. The system chosen for development, after experimental comparison of alternate technologies, features angle-beam ultrasonic transducers with fluid coupling to the flange edge; the emitting transducers create transverse waves that travel diagonally across the width of the flange, where an array of receiving transducers detect flaw reflections and flaw shadows. The system rolls along the box beam, surveying (screening) the top flange for the presence of flaws. In a first research task, conducted on a full-size beam specimen, we compared waves generated from different transducer locations, either the flange edge or the web face, and at different frequency ranges. At relatively low frequencies, such as 100 kHz, we observed Lamb wave modes, and at higher frequency, in the MHz range, we observed nearlylongitudinal waves with trailing pulses. In all cases we observed little attenuation by the wearing surface and little influence of reflection at the web-flange joints. At the conclusion of this task we made the design decision to use edgemounted transducers at relatively high frequency, with correspondingly short wavelength, for best scattering from flaws. In a second research task we conducted experiments at 55% scale on a steel plate, with machined flaws of different size, and detected flaws of target size for the intended application. We then compared the performance of bonded transducers, fluid-coupled transducers, and angle-beam (wedge) transducers; from that comparison we made the design decision to use wedges, which beam the wave to increase the scattering from flaws. We also compared the performance of wired transducers using fluid coupling to that of wireless (inductively coupled) transducers mounted permanently. Although the wireless transducers achieved flaw detection, the necessary spacing (determined experimentally) would have required an impractical number of transducers. Therefore, we made the design decision to use wedge transducers with fluid coupling. In a third research task we developed and tested a rolling system with a water channel for acoustic coupling, including a study of its sensitivity to misalignment, and in a fourth task we devised a data display to create a pattern of reflections or shadows that could be easily interpreted as evidence of a flaw. Finally, we conducted a field test on the full-size system in a region containing bolt holes, which act as a physical simulation of a flaw, and show successful detection of reflections and shadows from those holes.
Frequency wavenumber design of spiral macro fiber composite directional transducers
NASA Astrophysics Data System (ADS)
Carrara, Matteo; Ruzzene, Massimo
2015-04-01
This work is focused on design and testing of a novel class of transducers for Structural Health Monitoring (SHM), able to perform directional interrogation of plate-like structures. These transducers leverage guided waves (GWs), and in particular Lamb waves, that have emerged as a very prominent option for assessing the state of a structure during operation. GW-SHM approaches greatly benefit from the use of transducers with controllable directional characteristics, so that selective scanning of a surface can be performed to locate damage, impacts, or cracks. In the concepts that we propose, continuous beam steering and directional actuation are achieved through proper selection of the excitation frequency. The design procedure takes advantage of the wavenumber representation of the device, and formulates the problem using a Fourier-based approach. The active layer of the transducer is made of piezoelectric fibers embedded into an epoxy matrix, allowing the device to be flexible, and thus suitable for application on non{ at surfaces. Proper shaping of the electrodes pattern through a compensation function allows taking into account the anisotropy level introduced by the active layer. The resulting spiral frequency steerable acoustic actuator is a configuration that features (i) enhanced performance, (ii) reduced complexity, and (iii) reduced hardware requirements of such devices.
Lamb wave propagation in monocrystalline silicon wafers.
Fromme, Paul; Pizzolato, Marco; Robyr, Jean-Luc; Masserey, Bernard
2018-01-01
Monocrystalline silicon wafers are widely used in the photovoltaic industry for solar panels with high conversion efficiency. Guided ultrasonic waves offer the potential to efficiently detect micro-cracks in the thin wafers. Previous studies of ultrasonic wave propagation in silicon focused on effects of material anisotropy on bulk ultrasonic waves, but the dependence of the wave propagation characteristics on the material anisotropy is not well understood for Lamb waves. The phase slowness and beam skewing of the two fundamental Lamb wave modes A 0 and S 0 were investigated. Experimental measurements using contact wedge transducer excitation and laser measurement were conducted. Good agreement was found between the theoretically calculated angular dependency of the phase slowness and measurements for different propagation directions relative to the crystal orientation. Significant wave skew and beam widening was observed experimentally due to the anisotropy, especially for the S 0 mode. Explicit finite element simulations were conducted to visualize and quantify the guided wave beam skew. Good agreement was found for the A 0 mode, but a systematic discrepancy was observed for the S 0 mode. These effects need to be considered for the non-destructive testing of wafers using guided waves.
Murayama, Riichi; Makiyama, Shunnichi; Kodama, Mitutoshi; Taniguchi, Yasutoshi
2004-04-01
For inspection of a storage tank and pipeline in service, the application of an automatic inspection system (nondestructive inspection robot) is desirable, because manual inspection is difficult to perfectly and exactly perform due to the enormous amount of inspection needed. However, an ultrasonic nondestructive inspection robot with a piezoelectric oscillator needs to touch only the material surface to be directly inspected using a coupling medium. That is, the material surface and the sensor must always be held by constant pressure in the vertical direction on the material side. Actually, it is difficult to overcome these problems; thus an ultrasonic inspection robot could not be widely applied. We then tried to develop an ultrasonic inspection robot with an electromagnetic acoustic transducer (EMAT) which did not require a coupling medium to inspect the circumferential pipe parts. We developed a special EMAT that could transmit and receive alternately a Lamb wave with high sensitivity and a SH-plate wave without influence by the welded part. The method by which the inspection robot turned around the direction of the steel pipe surroundings was executed by observing the tape pasted in the direction of the steel pipe surroundings with an installed CCD camera. In this report, the basic mechanism of this inspection robot and an examination of results are described.
Harmonic generation of Lamb waves
NASA Astrophysics Data System (ADS)
Ing, Ros Kiri
2002-11-01
Lamb waves are dispersive waves that propagate following a number of distinct modes that depend on the values of the central frequency and frequency band. According to such properties and using the time-reversal process, it is shown that the hyperfocusing effect may be experienced [R. K. Ing and M. Fink, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 45, 1032-1043 (1998)]. Such a focusing effect both relates the time recompression of the dispersive Lamb waves and constructive interference on the focus point of the modes involved. The hyperfocusing effect is interesting because it allows the amplitude of the Lamb waves to reach huge values on the focus point. In our experiments, Lamb waves with normal amplitudes of micrometer values have been achieved on the free surface of a Duralumin plate of 3 mm thickness. By analyzing the Lamb waves in the neighborhood of the focus point using the 2-D Fourier transform technique, a nonlinear process of harmonic generation is then observed--the fundamental frequency component is centered at 1.5 MHz. This nonlinear process is under study and quantified.
Plane Wave SH₀ Piezoceramic Transduction Optimized Using Geometrical Parameters.
Boivin, Guillaume; Viens, Martin; Belanger, Pierre
2018-02-10
Structural health monitoring is a prominent alternative to the scheduled maintenance of safety-critical components. The nondispersive nature as well as the through-thickness mode shape of the fundamental shear horizontal guided wave mode (SH 0 ) make it a particularly attractive candidate for ultrasonic guided wave structural health monitoring. However, plane wave excitation of SH 0 at a high level of purity remains challenging because of the existence of the fundamental Lamb modes (A 0 and S 0 ) below the cutoff frequency thickness product of high-order modes. This paper presents a piezoelectric transducer concept optimized for plane SH 0 wave transduction based on the transducer geometry. The transducer parameter exploration was initially performed using a simple analytical model. A 3D multiphysics finite element model was then used to refine the transducer design. Finally, an experimental validation was conducted with a 3D laser Doppler vibrometer system. The analytical model, the finite element model, and the experimental measurement showed excellent agreement. The modal selectivity of SH 0 within a 20 ∘ beam opening angle at the design frequency of 425 kHz in a 1.59 mm aluminum plate was 23 dB, and the angle of the 6 dB wavefront was 86 ∘ .
Shasa, Desiree R.; Odhiambo, John F.; Long, Nathan M.; Tuersunjiang, Nuermaimaiti; Nathanielsz, Peter W.; Ford, Stephen P.
2014-01-01
Background/Objectives We have reported that maternal overnutrition/obesity (OB) in sheep resulting from feeding 150% of National Research Council (NRC) requirements throughout gestation, leads to maternal hyperglycemia and hyperinsulinemia. Further, newborn lambs born to OB vs. control-fed (CON, 100% of NRC) ewes exhibited greater adiposity, increased blood cortisol, insulin and glucose and the elimination of the postnatal leptin spike seen in lambs born to CON ewes. This early postnatal leptin peak is necessary for development of hypothalamic circuits which program appetite in later life. This study evaluated the multigenerational impact of OB on insulin:glucose dynamics of mature female F1 offspring fed only to requirements throughout gestation, and on their lambs (F2 generation). Design and Methods Adult F1 female offspring born to OB (n=10) or CON (n=7) ewes were utilized. All F1 ewes were subjected to a glucose tolerance test at midgestation and late gestation. Jugular blood was obtained from F2 lambs at birth (day 1) through postnatal day 11, and plasma glucose, insulin, cortisol and leptin concentrations determined. Dual Energy X-ray Absorptiometry (DEXA) was utilized to determine bone mineral density (BMD), bone mineral content (BMC), lean tissue mass, and fat tissue mass. Results Fasted blood glucose and insulin concentrations were greater (P < 0.05) in OBF1 than CONF1 ewes at mid- and late gestation. Further, after glucose infusion, both glucose and insulin concentrations remained higher in OBF1 ewes (P < 0.05) than CONF1 ewes demonstrating greater insulin resistance. Blood concentrations of glucose, insulin, and cortisol, and adiposity were higher (P < 0.01) in OBF2 lambs than CONF2 lambs at birth. Importantly, OBF2 lambs failed to exhibit the early postnatal leptin peak exhibited by CONF2 lambs. Conclusions These data suggest that these OBF2 lambs are predisposed to exhibit the same metabolic alterations as their mothers, suggesting a multi-generational programming effect. PMID:25354845
Strain Wave Acquisition by a Fiber Optic Coherent Sensor for Impact Monitoring
Sbarufatti, Claudio; Beligni, Alessio; Gilioli, Andrea; Ferrario, Maddalena; Mattarei, Marco; Martinelli, Mario; Giglio, Marco
2017-01-01
A novel fiber optic sensing technology for high frequency dynamics detection is proposed in this paper, specifically tailored for structural health monitoring applications based on strain wave analysis, for both passive impact identification and active Lamb wave monitoring. The sensing solution relies on a fiber optic-based interferometric architecture associated to an innovative coherent detection scheme, which retrieves in a completely passive way the high-frequency phase information of the received optical signal. The sensing fiber can be arranged into different layouts, depending on the requirement of the specific application, in order to enhance the sensor sensitivity while still ensuring a limited gauge length if punctual measures are required. For active Lamb wave monitoring, this results in a sensing fiber arranged in multiple loops glued on an aluminum thin panel in order to increase the phase signal only in correspondence to the sensing points of interest. Instead, for passive impact identification, the required sensitivity is guaranteed by simply exploiting a longer gauge length glued to the structure. The fiber optic coherent (FOC) sensor is exploited to detect the strain waves emitted by a piezoelectric transducer placed on the aluminum panel or generated by an impulse hammer, respectively. The FOC sensor measurements have been compared with both a numerical model based on Finite Elements and traditional piezoelectric sensors, confirming a good agreement between experimental and simulated results for both active and passive impact monitoring scenarios. PMID:28773154
NASA Astrophysics Data System (ADS)
Lu, Mingyu; Qu, Yongwei; Lu, Ye; Ye, Lin; Zhou, Limin; Su, Zhongqing
2012-04-01
An experimental study is reported in this paper demonstrating monitoring of surface-fatigue crack propagation in a welded steel angle structure using Lamb waves generated by an active piezoceramic transducer (PZT) network which was freely surface-mounted for each PZT transducer to serve as either actuator or sensor. The fatigue crack was initiated and propagated in welding zone of a steel angle structure by three-point bending fatigue tests. Instead of directly comparing changes between a series of specific signal segments such as S0 and A0 wave modes scattered from fatigue crack tips, a variety of signal statistical parameters representing five different structural status obtained from marginal spectrum in Hilbert-huang transform (HHT), indicating energy progressive distribution along time period in the frequency domain including all wave modes of one wave signal were employed to classify and distinguish different structural conditions due to fatigue crack initiation and propagation with the combination of using principal component analysis (PCA). Results show that PCA based on marginal spectrum is effective and sensitive for monitoring the growth of fatigue crack although the received signals are extremely complicated due to wave scattered from weld, multi-boundaries, notch and fatigue crack. More importantly, this method indicates good potential for identification of integrity status of complicated structures which cause uncertain wave patterns and ambiguous sensor network arrangement.
Adaptive elastic metasurfaces for wave front manipulation
NASA Astrophysics Data System (ADS)
Li, Shilong; Xu, Jiawen; Tang, Jiong
2018-04-01
In this research, by combining the concept of elastic metasurfaces with piezoelectric transducer with shunted circuitry, we investigate the designs of elastic metasurfaces, consisting of an array of piezoelectric transducers shunted with negative capacitance, which is capable of modulating wave fronts adaptively. In order to construct different adaptive elastic metasurfaces, different phase profiles along the interface can be framed through properly adjusting the negative capacitance values. Flat planar lenses for focusing transmitted A0 Lamb waves are achieved, and possess the flexibility of changing focal locations through electromechanical tunings. Additionally, nonparaxial self-bending beams with arbitrary trajectories and source illusion devices can also be accomplished owing to the free manipulation of phase shifts. With their versatility and tunability, the adaptive elastic metasurfaces could pave new avenues to a wide variety of potential applications, such as nondestructive testing, ultrasound imaging, and caustic engineering.
Using PVDF for wavenumber-frequency analysis and excitation of guided waves
NASA Astrophysics Data System (ADS)
Ren, Baiyang; Cho, Hwanjeong; Lissenden, Cliff J.
2018-04-01
The role of transducers in nondestructive evaluation using ultrasonic guided waves cannot be overstated. Energy conversion from electrical to mechanical for actuation and then back to electrical for signal processing broadly describes transduction, but there are many other aspects of transducers that determine their effectiveness. Recently we have reported on polyvinylidene difluoride (PVDF) array sensors that enable determination of the wavenumber spectrum, which enables modal content in the received signal to be characterized. Modal content is an important damage indicator because, for example, mode conversion is a frequent consequence of wave interaction with defects. Some of the positive attributes of PVDF sensors are: broad frequency bandwidth, compliance for use on curved surfaces, limited influence on the passing wave, minimal cross-talk between elements, low profile, low mass, and inexpensive. The anisotropy of PVDF films also enables them to receive either Lamb waves or shear horizontal waves by proper alignment of the material principal coordinate axes. Placing a patterned set of electrodes on the PVDF film provides data from an array of elements. A linear array of elements is used to enable a 2D fast Fourier transform to determine the wavenumber spectrum of both Lamb waves and shear horizontal waves in an aluminum plate. Moreover, since PVDF film can sustain high voltage excitation, high power pulsers can be used to improve the signal-to-noise ratio. The capability of PVDF as a transmitter has been demonstrated with high voltage excitation.
Ultrasonic wave-based structural health monitoring embedded instrument.
Aranguren, G; Monje, P M; Cokonaj, Valerijan; Barrera, Eduardo; Ruiz, Mariano
2013-12-01
Piezoelectric sensors and actuators are the bridge between electronic and mechanical systems in structures. This type of sensor is a key element in the integrity monitoring of aeronautic structures, bridges, pressure vessels, wind turbine blades, and gas pipelines. In this paper, an all-in-one system for Structural Health Monitoring (SHM) based on ultrasonic waves is presented, called Phased Array Monitoring for Enhanced Life Assessment. This integrated instrument is able to generate excitation signals that are sent through piezoelectric actuators, acquire the received signals in the piezoelectric sensors, and carry out signal processing to check the health of structures. To accomplish this task, the instrument uses a piezoelectric phased-array transducer that performs the actuation and sensing of the signals. The flexibility and strength of the instrument allow the user to develop and implement a substantial part of the SHM technique using Lamb waves. The entire system is controlled using configuration software and has been validated through functional, electrical loading, mechanical loading, and thermal loading resistance tests.
Demonstration of Shear Waves, Lamb Waves, and Rayleigh Waves by Mode Conversion.
ERIC Educational Resources Information Center
Leung, W. P.
1980-01-01
Introduces an experiment that can be demonstrated in the classroom to show that shear waves, Rayleigh waves, and Lamb waves can be easily generated and observed by means of mode conversion. (Author/CS)
Detection of crack in thin cylindrical pipes using piezo-actuated Lamb waves
NASA Astrophysics Data System (ADS)
Tua, P. S.; Quek, S. T.; Wang, Q.
2005-05-01
The detection of cracks in beams and plates using piezo-actuated Lamb waves has been presented in the last SPIE Symposium. This paper is an extension of the technique to pipes. It has been shown that for a thin-walled pipe, the assumption of Lamb wave propagation is valid. Such waves can be efficiently excited using piezoceramic transducers (PZT) with good control on the pulse characteristics to assess the health of structural components, such as the presence of cracks. In this paper, a systematic methodology to detect and locate cracks in homogenous cylinder/pipe based on the time-of-flight and strength analysis of propagating Lamb wave is proposed. By observing the attenuation in strength of the direct wave incidence at the sensor, the presence of a crack along the propagation path can be determined. At least four actuation positions, two on each end of the pipe segment of interest, are needed to exhaustively interrogate for the presence of cracks. The detailed procedure for locating and tracing the geometry of the crack(s) is described. It is shown experimentally that the detection using circular PZT actuator and sensor, with dimensions of 5.0 mm diameter and 0.5 mm thick, is possible for an aluminum pipe segment of up to at least 4.0 m in length. The proposed methodology is also explored for the aluminum pipe under more practical situations, such as burying it in sand with only the actuator and sensor positions exposed. Experimental results obtained showed the feasibility of detecting the 'concealed' crack on the pipe buried in sand.
Neural-Fuzzy model Based Steel Pipeline Multiple Cracks Classification
NASA Astrophysics Data System (ADS)
Elwalwal, Hatem Mostafa; Mahzan, Shahruddin Bin Hj.; Abdalla, Ahmed N.
2017-10-01
While pipes are cheaper than other means of transportation, this cost saving comes with a major price: pipes are subject to cracks, corrosion etc., which in turn can cause leakage and environmental damage. In this paper, Neural-Fuzzy model for multiple cracks classification based on Lamb Guide Wave. Simulation results for 42 sample were collected using ANSYS software. The current research object to carry on the numerical simulation and experimental study, aiming at finding an effective way to detection and the localization of cracks and holes defects in the main body of pipeline. Considering the damage form of multiple cracks and holes which may exist in pipeline, to determine the respective position in the steel pipe. In addition, the technique used in this research a guided lamb wave based structural health monitoring method whereas piezoelectric transducers will use as exciting and receiving sensors by Pitch-Catch method. Implementation of simple learning mechanism has been developed specially for the ANN for fuzzy the system represented.
A Baseline-Free Defect Imaging Technique in Plates Using Time Reversal of Lamb Waves
NASA Astrophysics Data System (ADS)
Hyunjo, Jeong; Sungjong, Cho; Wei, Wei
2011-06-01
We present an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional sidebands that contain the time-of-flight information on the defect location. One of the side-band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free imaging of a defect.
NASA Astrophysics Data System (ADS)
Zahedi, Sulmaz
This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.
Zhou, Wensong; Li, Hui; Yuan, Fuh-Gwo
2015-03-01
A new piezoelectric wafer made from a PMN-PT single crystal with dominant piezoelectric coefficient d36 is proposed to generate and detect guided waves on isotropic plates. The in-plane shear coupled with electric field arising from the piezoelectric coefficient is not usually present for conventional piezoelectric wafers, such as lead zirconate titanate (PZT). The direct piezoelectric effect of coefficient d36 indicates that under external in-plane shear stress the charge is induced on a face perpendicular to the poled z-direction. On thin plates, this type of piezoelectric wafer will generate shear horizontal (SH) waves in two orthogonal wave propagation directions as well as two Lamb wave modes in other wave propagation directions. Finite element analyses are employed to explore the wave disturbance in terms of time-varying displacements excited by the d36 wafer in different directions of wave propagation to understand all the guided wave modes accurately. Experiments are conducted to examine the voltage responses received by this type of wafer, and also investigate results of tuning frequency and effects of d31 piezoelectric coefficient, which is intentionally ignored in the finite element analysis. All results demonstrate the main features and utility of proposed d36 piezoelectric wafer for guided wave generation and detection in structural health monitoring. Copyright © 2014 Elsevier B.V. All rights reserved.
Inhaled carbon monoxide does not cause pulmonary vasodilation in the late-gestation fetal lamb.
Grover, T R; Rairigh, R L; Zenge, J P; Abman, S H; Kinsella, J P
2000-04-01
As observed with nitric oxide (NO), carbon monoxide (CO) binds and may activate soluble guanylate cyclase and increase cGMP levels in smooth muscle cells in vitro. Because inhaled NO (I(NO)) causes potent and sustained pulmonary vasodilation, we hypothesized that inhaled CO (I(CO)) may have similar effects on the perinatal lung. To determine whether I(CO) can lower pulmonary vascular resistance (PVR) during the perinatal period, we studied the effects of I(CO) on late-gestation fetal lambs. Catheters were placed in the main pulmonary artery, left pulmonary artery (LPA), aorta, and left atrium to measure pressure. An ultrasonic flow transducer was placed on the LPA to measure blood flow to the left lung. After baseline measurements, fetal lambs were mechanically ventilated with a hypoxic gas mixture (inspired O(2) fraction < 0.10) to maintain a constant fetal arterial PO(2). After 60 min (baseline), the lambs were treated with I(CO) [5-2,500 parts/million (ppm)]. Comparisons were made with I(NO) (5 and 20 ppm) and combined I(NO) (5 ppm) and I(CO) (100 and 2,500 ppm). We found that I(CO) did not alter left lung blood flow or PVR at any of the study doses. In contrast, low-dose I(NO) decreased PVR by 47% (P < 0.005). The combination of I(NO) and I(CO) did not enhance the vasodilator response to I(NO). To determine whether endogenous CO contributes to vascular tone in the fetal lung, zinc protoporphyrin IX, an inhibitor of heme oxygenase, was infused into the LPA in three lambs. Zinc protoporphyrin IX had no effect on baseline PVR, aortic pressure, or the pressure gradient across the ductus arteriosus. We conclude that I(CO) does not cause vasodilation in the near-term ovine transitional circulation, and endogenous CO does not contribute significantly to baseline pulmonary vascular tone or ductus arteriosus tone in the late-gestation ovine fetus.
NASA Astrophysics Data System (ADS)
Castaings, Michel; Hosten, Bernard
2003-05-01
The propagation of Lamb-like waves in sandwich plates made of anisotropic and viscoelastic material layers is studied. A semi-analytical model is described and used for predicting the dispersion curves (phase velocity, energy velocity, and complex wave-number) and the through-thickness distribution fields (displacement, stress, and energy flow). Guided modes propagating along a test-sandwich plate are shown to be quite different than classical Lamb modes, because this structure does not have the mirror symmetry, contrary to most of composite material plates. Moreover, the viscoelastic material properties imply complex roots of the dispersion equation to be found that lead to connections between some of the dispersion curves, meaning that some of the modes get coupled together. Gradual variation from zero to nominal values of the imaginary parts of the viscoelastic moduli shows that the mode coupling depends on the level of material viscoelasticity, except for one particular case where this phenomenon exists whether the medium is viscoelastic or not. The model is used to quantify the sensitivity of both the dispersion curves and the through-thickness mode shapes to the level of material viscoelasticity, and to physically explain the mode-coupling phenomenon. Finite element software is also used to confirm results obtained for the purely elastic structure. Finally, experiments are made using ultrasonic, air-coupled transducers for generating and detecting guided modes in the test-sandwich structure. The mode-coupling phenomenon is then confirmed, and the potential of the air-coupled system for developing single-sided, contactless, NDT applications of such structures is discussed.
A cross-sectional study of 329 farms in England to identify risk factors for ovine clinical mastitis
Cooper, S.; Huntley, S.J.; Crump, R.; Lovatt, F.; Green, L.E.
2016-01-01
The aims of this study were to estimate the incidence rate of clinical mastitis (IRCM) and identify risk factors for clinical mastitis in suckler ewes to generate hypotheses for future study. A postal questionnaire was sent to 999 randomly selected English sheep farmers in 2010 to gather data on farmer reported IRCM and flock management practices for the calendar year 2009, of which 329 provided usable information. The mean IRCM per flock was 1.2/100 ewes/year (CI:1.10:1.35). The IRCM was 2.0, 0.9 and 1.3/100 ewes/year for flocks that lambed indoors, outdoors and a combination of both, respectively. Farmers ran a variety of managements before, during and after lambing that were not comparable within one model, therefore six mixed effects over-dispersed Poisson regression models were developed. Factors significantly associated with increased IRCM were increasing percentage of the flock with poor udder conformation, increasing mean number of lambs reared/ewe and when some or all ewes lambed in barns compared with outdoors (Model 1). For ewes housed in barns before lambing (Model 2), concrete, earth and other materials were associated with an increase in IRCM compared with hardcore floors (an aggregate of broken bricks and stones). For ewes in barns during lambing (Model 3), an increase in IRCM was associated with concrete compared with hardcore flooring and where bedding was stored covered outdoors or in a building compared with bedding stored outdoors uncovered. For ewes in barns after lambing (Model 4), increased IRCM was associated with earth compared with hardcore floors, and when fresh bedding was added once per week compared with at a frequency of ≤2 days or twice/week. The IRCM was lower for flocks where some or all ewes remained in the same fields before, during and after lambing compared with flocks that did not (Model 5). Where ewes and lambs were turned outdoors after lambing (Model 6), the IRCM increased as the age of the oldest lambs at turnout increased. We conclude that the reported IRCM is low but highly variable and that the complexity of management of sheep around lambing limits the insight into generating hypotheses at flock level for risks for clinical mastitis across the whole industry. Whilst indoor production was generally associated with an increased IRCM, for ewes with large litter size indoor lambing was protective, we hypothesise that this is possibly because of better nutrition or reduced exposure to poor weather and factors associated with hygiene. PMID:26809634
Conversion of evanescent Lamb waves into propagating waves via a narrow aperture edge.
Yan, Xiang; Yuan, Fuh-Gwo
2015-06-01
This paper presents a quantitative study of conversion of evanescent Lamb waves into propagating in isotropic plates. The conversion is substantiated by prescribing time-harmonic Lamb displacements/tractions through a narrow aperture at an edge of a semi-infinite plate. Complex-valued dispersion and group velocity curves are employed to characterize the conversion process. The amplitude coefficient of the propagating Lamb modes converted from evanescent is quantified based on the complex reciprocity theorem via a finite element analysis. The power flow generated into the plate can be separated into radiative and reactive parts made on the basis of propagating and evanescent Lamb waves, where propagating Lamb waves are theoretically proved to radiate pure real power flow, and evanescent Lamb waves carry reactive pure imaginary power flow. The propagating power conversion efficiency is then defined to quantitatively describe the conversion. The conversion efficiency is strongly frequency dependent and can be significant. With the converted propagating waves from evanescent, sensors at far-field can recapture some localized damage information that is generally possessed in evanescent waves and may have potential application in structural health monitoring.
New improvement of the combined optical fiber transducer for landslide monitoring
NASA Astrophysics Data System (ADS)
Zhu, Z.-W.; Yuan, Q.-Y.; Liu, D.-Y.; Liu, B.; Liu, J.-C.; Luo, H.
2014-08-01
Landslide monitoring is important in predicting the behavior of landslides, thereby ensuring environmental, life, and property safety. On the basis of our previous studies, we conducted the double shear test by using a third-generation optical fiber transducer that uses expandable polystyrene (EPS) as base material. However, the third-generation transducer has poor performance when cohesive force is present between the grout and capillary stainless steel pipe of the transducer. Thus, the fourth-generation optical fiber transducer was invented. Similar to the third-generation transducer, the fourth-generation transducer also used EPS as its base material. Single shear test was conducted on the fourth-generation transducer after being grouted with cement mortar (1 : 1 mix ratio). The micro-bend loss mechanism of the optical fiber was considered, and the optical time domain reflectometry instrument was used. The fact that the loss sequence of optical fibers subjected to loading is different at various locations is found. The relationship of the loading-point displacement vs. optical fiber sliding distance and optical loss were measured. Results show that the maximum initial measurement precision of the newly proposed device is 1 mm, the corresponding sliding distance is 21 mm, and the dynamic range is 0-20 mm. The fourth-generation transducer can measure the movement direction of loadings, thus making this transducer applicable for landslide monitoring.
Kassou, Koussila; Remram, Youcef; Laugier, Pascal; Minonzio, Jean-Gabriel
2017-11-01
Guided waves-based techniques are currently under development for quantitative cortical bone assessment. However, the signal interpretation is challenging due to multiple mode overlapping. To overcome this limitation, dry point-contact transducers have been used at low frequencies for a selective excitation of the zeroth order anti-symmetric Lamb A0 mode, a mode whose dispersion characteristics can be used to infer the thickness of the waveguide. In this paper, our purpose was to extend the technique by combining a dry point-contact transducers approach to the SVD-enhanced 2-D Fourier transform in order to measure the dispersion characteristics of the flexural mode. The robustness of our approach is assessed on bone-mimicking phantoms covered or not with soft tissue-mimicking layer. Experiments were also performed on a bovine bone. Dispersion characteristics of measured modes were extracted using a SVD-based signal processing technique. The thickness was obtained by fitting a free plate model to experimental data. The results show that, in all studied cases, the estimated thickness values are in good agreement with the actual thickness values. From the results, we speculate that in vivo cortical thickness assessment by measuring the flexural wave using point-contact transducers is feasible. However, this assumption has to be confirmed by further in vivo studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Ripoll, G; Lobón, S; Joy, M
2018-09-01
Measurement of thiobarbituric acid reactive substances (TBARS) is a well-established method for determine lipid oxidation in meat. This assay, however, is time-consuming and generates undesired chemical waste. Dam's milk is the principal source of vitamins and provitamins that delay lipid oxidation of light lamb meat; these compounds are stored in the lamb's muscle tissue. Hence, lamb meat could be used to determine the origin of the dam's diet. The aim of this study is to evaluate Near-infrared reflectance spectroscopy (NIRS) as a tool for determining the lipid peroxidation of light lamb meat and differentiate the meat of light lambs according the diet of their dams during lactation (grazing alfalfa, lucerne, or fed a total mixed ration). NIRS using select wavelengths was able to detect the lipid oxidation of meat (TBARS method). NIRS can detect analytes at concentrations of parts per million. Moreover, the feed diets were discriminated successfully. Copyright © 2018 Elsevier Ltd. All rights reserved.
A Novel Strategy for landslide displacement and its direction monitoring
NASA Astrophysics Data System (ADS)
Zhu, Z.-W.; Yuan, Q.-Y.; Liu, D.-Y.; Liu, B.; Liu, J.-C.; Luo, H.
2013-12-01
Landslide monitoring is important in predicting the behavior of landslides, thereby ensuring environmental, life, and property safety. On the basis of our previous studies, we conducted the double shear test by using a third-generation optical fiber transducer that uses expandable polystyrene (EPS) as base material. However, the third-generation transducer has poor performance when cohesive force is present between the grout and capillary stainless steel pipe of the transducer. Thus, the fourth-generation optical fiber transducer was invented. Similar to the third-generation transducer, the fourth-generation transducer also used EPS as its base material. Single shear test was conducted on the fourth-generation transducer after being grouted with cement mortar (1:1 mix ratio). The micro-bend loss mechanism of the optical fiber was considered, and the optical time domain reflectometry instrument was used. The fact that the loss sequence of optical fibers subjected to loading is different at various locations is found. The relationship of the loading-point displacement VS. optical fiber sliding distance and optical loss were measured. Results show that the maximum initial measurement precision of the newly proposed device is 1mm, the corresponding sliding distance is 21 mm, and the dynamic range is 0-20 mm. The fourth-generation transducer can measure the movement direction of loadings, thus making this transducer applicable for landslide monitoring.
2012-01-20
ultrasonic Lamb waves to plastic strain and fatigue life. Theory was developed and validated to predict second harmonic generation for specific mode... Fatigue and damage generation and progression are processes consisting of a series of interrelated events that span large scales of space and time...strain and fatigue life A set of experiments were completed that worked to relate the acoustic nonlinearity measured with Lamb waves to both the
Detection and generation of first sound in4He by vibrating superleak transducers
NASA Astrophysics Data System (ADS)
Giordano, N.; Edison, N.
1986-07-01
Measurement is made of the first-sound generation and detection efficiencies of vibrating superleak transducers (VSTs) operated in superfluid4He. This is accomplished by using an ordinary pressure transducer to generate first sound with a VST as the detector, and by using a pressure transducer to detect the sound generated by a VST. The results are in reasonably good agreement with the current theory of VST operation.
Detection and generation of first sound in /sup 4/He by vibrating superleak transducers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giordano, N.; Edison, N.
Measurement is made of the first-sound generation and detection efficiencies of vibrating superleak transducers (VSTs) operated in superfluid /sup 4/He. This is accomplished by using an ordinary pressure transducer to generate first sound with a VST as the detector, and by using a pressure transducer to detect the sound generated by a VST. The results are in reasonably good agreement with the current theory of VST operation.
Cooper, S; Huntley, S J; Crump, R; Lovatt, F; Green, L E
2016-03-01
The aims of this study were to estimate the incidence rate of clinical mastitis (IRCM) and identify risk factors for clinical mastitis in suckler ewes to generate hypotheses for future study. A postal questionnaire was sent to 999 randomly selected English sheep farmers in 2010 to gather data on farmer reported IRCM and flock management practices for the calendar year 2009, of which 329 provided usable information. The mean IRCM per flock was 1.2/100 ewes/year (CI:1.10:1.35). The IRCM was 2.0, 0.9 and 1.3/100 ewes/year for flocks that lambed indoors, outdoors and a combination of both, respectively. Farmers ran a variety of managements before, during and after lambing that were not comparable within one model, therefore six mixed effects over-dispersed Poisson regression models were developed. Factors significantly associated with increased IRCM were increasing percentage of the flock with poor udder conformation, increasing mean number of lambs reared/ewe and when some or all ewes lambed in barns compared with outdoors (Model 1). For ewes housed in barns before lambing (Model 2), concrete, earth and other materials were associated with an increase in IRCM compared with hardcore floors (an aggregate of broken bricks and stones). For ewes in barns during lambing (Model 3), an increase in IRCM was associated with concrete compared with hardcore flooring and where bedding was stored covered outdoors or in a building compared with bedding stored outdoors uncovered. For ewes in barns after lambing (Model 4), increased IRCM was associated with earth compared with hardcore floors, and when fresh bedding was added once per week compared with at a frequency of ≤2 days or twice/week. The IRCM was lower for flocks where some or all ewes remained in the same fields before, during and after lambing compared with flocks that did not (Model 5). Where ewes and lambs were turned outdoors after lambing (Model 6), the IRCM increased as the age of the oldest lambs at turnout increased. We conclude that the reported IRCM is low but highly variable and that the complexity of management of sheep around lambing limits the insight into generating hypotheses at flock level for risks for clinical mastitis across the whole industry. Whilst indoor production was generally associated with an increased IRCM, for ewes with large litter size indoor lambing was protective, we hypothesise that this is possibly because of better nutrition or reduced exposure to poor weather and factors associated with hygiene. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Robust laser-based detection of Lamb waves using photo-EMF sensors
NASA Astrophysics Data System (ADS)
Klein, Marvin B.; Bacher, Gerald D.
1998-03-01
Lamb waves are easily generated and detected using laser techniques. It has been shown that both symmetric and antisymmetric modes can be produced, using single-spot and phased array generation. Detection has been demonstrated with Michelson interferometers, but these instruments can not function effectively on rough surfaces. By contrast, the confocal Fabry-Perot interferometer can interrogate rough surfaces, but generally is not practical for operation below 300 kHz. In this paper we will present Lamb wave data on a number of parts using a robust, adaptive receiver based on photo-emf detection. This receiver has useful sensitivity down to at least 100 kHz, can process speckled beams and can be easily configured to measure both out-of-plane and in- plane motion with a single probe beam.
NASA Astrophysics Data System (ADS)
Yuan, Shenfang; Chen, Jian; Yang, Weibo; Qiu, Lei
2017-08-01
Fatigue crack growth prognosis is important for prolonging service time, improving safety, and reducing maintenance cost in many safety-critical systems, such as in aircraft, wind turbines, bridges, and nuclear plants. Combining fatigue crack growth models with the particle filter (PF) method has proved promising to deal with the uncertainties during fatigue crack growth and reach a more accurate prognosis. However, research on prognosis methods integrating on-line crack monitoring with the PF method is still lacking, as well as experimental verifications. Besides, the PF methods adopted so far are almost all sequential importance resampling-based PFs, which usually encounter sample impoverishment problems, and hence performs poorly. To solve these problems, in this paper, the piezoelectric transducers (PZTs)-based active Lamb wave method is adopted for on-line crack monitoring. The deterministic resampling PF (DRPF) is proposed to be used in fatigue crack growth prognosis, which can overcome the sample impoverishment problem. The proposed method is verified through fatigue tests of attachment lugs, which are a kind of important joint component in aerospace systems.
Lamb mode selection for accurate wall loss estimation via guided wave tomography
NASA Astrophysics Data System (ADS)
Huthwaite, P.; Ribichini, R.; Lowe, M. J. S.; Cawley, P.
2014-02-01
Guided wave tomography offers a method to accurately quantify wall thickness losses in pipes and vessels caused by corrosion. This is achieved using ultrasonic waves transmitted over distances of approximately 1-2m, which are measured by an array of transducers and then used to reconstruct a map of wall thickness throughout the inspected region. To achieve accurate estimations of remnant wall thickness, it is vital that a suitable Lamb mode is chosen. This paper presents a detailed evaluation of the fundamental modes, S0 and A0, which are of primary interest in guided wave tomography thickness estimates since the higher order modes do not exist at all thicknesses, to compare their performance using both numerical and experimental data while considering a range of challenging phenomena. The sensitivity of A0 to thickness variations was shown to be superior to S0, however, the attenuation from A0 when a liquid loading was present was much higher than S0. A0 was less sensitive to the presence of coatings on the surface of than S0.
Imaging of a Defect in Thin Plates Using the Time Reversal of Single Mode Lamb Waves
NASA Astrophysics Data System (ADS)
Jeong, Hyunjo; Lee, Jung-Sik; Bae, Sung-Min
2011-06-01
This paper presents an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional sidebands that contain the time-of-flight information on the defect location. One of the side band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free detection of a defect, so that experimental studies are needed to verify the proposed method and to be applied to real structure.
Allain, D; Foulquié, D; Autran, P; Francois, D; Bouix, J
2014-01-01
The Romane sheep breed proved to be adapted to harsh conditions with high prolificacy and lamb survival in outdoor farming, even under bad climate conditions. This breed shows large variability in its fleece type at birth and it has been suggested that lamb survival could be related to birthcoat type. The aim of the present study was to: i) characterize the coat of the lamb at birth and quantify lamb survival in relation to the birthcoat type and its protective properties concerning heat loss in the Romane breed raised under permanent exposure outdoors from birth, and ii) estimate genetic parameters of birthcoat type in relation to lamb survival and live body weight. A total of 7,880 lambs from 104 sires and 1,664 dams were used in a 14-yr experiment. The pedigree file included 9,625 individuals over 15 generations. Birthcoat type, coat surface temperature, coat depth, lamb survival, and growth were measured from birth to weaning. Weather data (temperature, wind speed, relative humidity, and precipitation) were recorded daily during lambing time. Two types of coats were observed at birth: hairy coat (62.9% of lambs) with a long coat depth (average 23.3 mm) or woolly 1 (37.1% of lambs) with a short coat depth (average 8.3 mm). Birthcoat type was an important factor affecting lamb survival and growth from birth in the Romane breed. Total mortality rate was significantly less in hairy-bearing coat lambs than in short-woolly coat ones: 7.0% vs. 9.6%, 11.6 % vs. 14.8%, and 15.7 % vs. 20.1 % at 2, 10, and 50 d, respectively, and the relative risks of death increased by 37%, 67%, and 46 % at 2, 10, and 50 d of age, respectively, in short-woolly lambs. At birth, a significant lower coat surface temperature, indicating less heat loss, was observed in long-hairy coat lambs compared with others (21.1°C vs. 26.1°C). Heavier body weights and better growth performances up to the age of 50 d were observed in long-hairy-bearing coat lambs. Lamb survival was positively correlated to weather conditions at lambing time in short-woolly lambs, whereas no relation was observed in hairy-coat lambs. Heritability estimate of birthcoat type (hairy or woolly) is high (0.88). Genetic correlations between birthcoat type, lamb survival, and live body weight at birth were positive and moderate, suggesting that it would be beneficial to take birthcoat into account as an adaptive trait in any genetic strategies for sheep production in harsh conditions on rangelands.
Rao, Jing; Ratassepp, Madis; Lisevych, Danylo; Hamzah Caffoor, Mahadhir; Fan, Zheng
2017-12-12
Corrosion is a major safety and economic concern to various industries. In this paper, a novel ultrasonic guided wave tomography (GWT) system based on self-designed piezoelectric sensors is presented for on-line corrosion monitoring of large plate-like structures. Accurate thickness reconstruction of corrosion damages is achieved by using the dispersive regimes of selected guided waves and a reconstruction algorithm based on full waveform inversion (FWI). The system makes use of an array of miniaturised piezoelectric transducers that are capable of exciting and receiving highly dispersive A0 Lamb wave mode at low frequencies. The scattering from transducer array has been found to have a small effect on the thickness reconstruction. The efficiency and the accuracy of the new system have been demonstrated through continuous forced corrosion experiments. The FWI reconstructed thicknesses show good agreement with analytical predictions obtained by Faraday's law and laser measurements, and more importantly, the thickness images closely resemble the actual corrosion sites.
Damage Identification of Wind Turbine Blades Using Piezoelectric Transducers
Choi, Seong-Won; Farinholt, Kevin M.; Taylor, Stuart G.; ...
2014-01-01
This paper presents the experimental results of active-sensing structural health monitoring (SHM) techniques, which utilize piezoelectric transducers as sensors and actuators, for determining the structural integrity of wind turbine blades. Specifically, Lamb wave propagations and frequency response functions at high frequency ranges are used to estimate the condition of wind turbine blades. For experiments, a 1 m section of a CX-100 blade is used. The goal of this study is to assess and compare the performance of each method in identifying incipient damage with a consideration given to field deployability. Overall, these methods yielded a sufficient damage detection capability to warrantmore » further investigation. This paper also summarizes the SHM results of a full-scale fatigue test of a 9 m CX-100 blade using piezoelectric active sensors. This paper outlines considerations needed to design such SHM systems, experimental procedures and results, and additional issues that can be used as guidelines for future investigations.« less
A straightforward experimental method to evaluate the Lamb-Mössbauer factor of a 57Co/Rh source
NASA Astrophysics Data System (ADS)
Spina, G.; Lantieri, M.
2014-01-01
In analyzing Mössbauer spectra by means of the integral transmission function, a correct evaluation of the recoilless fs factor of the source at the position of the sample is needed. A novel method to evaluate fs for a 57Co source is proposed. The method uses the standard transmission experimental set up and it does not need further measurements but the ones that are mandatory in order to center the Mössbauer line and to calibrate the Mössbauer transducer. Firstly, the background counts are evaluated by collecting a standard Multi Channel Scaling (MCS) spectrum of a tick metal iron foil absorber and two Pulse Height Analysis (PHA) spectra with the same life-time and setting the maximum velocity of the transducer at the same value of the MCS spectrum. Secondly, fs is evaluated by fitting the collected MCS spectrum throughout the integral transmission approach. A test of the suitability of the technique is presented, too.
Steen, Arvid; Strøm, Turid; Bernhoft, Aksel
2008-03-31
Selenium is part of the antioxidant defence system in animals and humans. The available selenium concentration in soil is low in many regions of the world. The purpose of this study was to evaluate the effect of organic versus inorganic selenium supplementation on selenium status of ewes, their lambs, and slaughter lambs. Ewes on four organic farms were allocated five or six to 18 pens. The ewes were given either 20 mg/kg inorganic selenium as sodium selenite or organic selenium as selenized nonviable yeast supplementation for the two last months of pregnancy. Stipulated selenium concentrations in the rations were below 0.40 mg/kg dry matter. In addition 20 male lambs were given supplements from November until they were slaughtered in March. Silage, hay, concentrates, and individual ewe blood samples were taken before and after the mineral supplementation period, and blood samples were taken from the newborn lambs. Blood samples from ewes and lambs in the same pens were pooled. Muscle samples were taken from slaughter lambs in March. Selenium concentrations were determined by atomic absorption spectrometry with a hydride generator system. In the ANOVA model, selenium concentration was the continuous response variable, and selenium source and farm were the nominal effect variables. Two-sample t-test was used to compare selenium concentrations in muscle samples from the slaughtered lambs that received either organic or inorganic selenium supplements. In all ewe pens the whole blood selenium concentrations increased during the experimental period. In addition, ewe pens that received organic selenium had significantly higher whole blood selenium concentrations (mean 0.28 microg/g) than ewe pens that received inorganic selenium (mean 0.24 microg/g). Most prominent, however, was the difference in their lambs; whole blood mean selenium concentration in lambs from mothers that received organic selenium (mean 0.27 microg/g) was 30% higher than in lambs from mothers that received inorganic selenium (mean 0.21 microg/g). Slaughter lambs that received organic selenium had 50% higher meat selenium concentrations (mean 0.12 mg/kg wet weight) than lambs that received inorganic selenium (mean 0.08 mg/kg wet weight). Organic selenium supplementation gave higher selenium concentration in ewe and newborn lamb blood and slaughter lamb meat than inorganic selenium supplementation.
Steen, Arvid; Strøm, Turid; Bernhoft, Aksel
2008-01-01
Background Selenium is part of the antioxidant defence system in animals and humans. The available selenium concentration in soil is low in many regions of the world. The purpose of this study was to evaluate the effect of organic versus inorganic selenium supplementation on selenium status of ewes, their lambs, and slaughter lambs. Methods Ewes on four organic farms were allocated five or six to 18 pens. The ewes were given either 20 mg/kg inorganic selenium as sodium selenite or organic selenium as selenized nonviable yeast supplementation for the two last months of pregnancy. Stipulated selenium concentrations in the rations were below 0.40 mg/kg dry matter. In addition 20 male lambs were given supplements from November until they were slaughtered in March. Silage, hay, concentrates, and individual ewe blood samples were taken before and after the mineral supplementation period, and blood samples were taken from the newborn lambs. Blood samples from ewes and lambs in the same pens were pooled. Muscle samples were taken from slaughter lambs in March. Selenium concentrations were determined by atomic absorption spectrometry with a hydride generator system. In the ANOVA model, selenium concentration was the continuous response variable, and selenium source and farm were the nominal effect variables. Two-sample t-test was used to compare selenium concentrations in muscle samples from the slaughtered lambs that received either organic or inorganic selenium supplements. Results In all ewe pens the whole blood selenium concentrations increased during the experimental period. In addition, ewe pens that received organic selenium had significantly higher whole blood selenium concentrations (mean 0.28 μg/g) than ewe pens that received inorganic selenium (mean 0.24 μg/g). Most prominent, however, was the difference in their lambs; whole blood mean selenium concentration in lambs from mothers that received organic selenium (mean 0.27 μg/g) was 30% higher than in lambs from mothers that received inorganic selenium (mean 0.21 μg/g). Slaughter lambs that received organic selenium had 50% higher meat selenium concentrations (mean 0.12 mg/kg wet weight) than lambs that received inorganic selenium (mean 0.08 mg/kg wet weight). Conclusion Organic selenium supplementation gave higher selenium concentration in ewe and newborn lamb blood and slaughter lamb meat than inorganic selenium supplementation. PMID:18377659
Acousto-ultrasonics to Assess Material and Structural Properties
NASA Technical Reports Server (NTRS)
Kautz, Harold E.
2002-01-01
This report was created to serve as a manual for applying the Acousto-Ultrasonic NDE method, as practiced at NASA Glenn, to the study of materials and structures for a wide range of applications. Three state of the art acousto-ultrasonic (A-U) analysis parameters, ultrasonic decay (UD) rate, mean time
Damping, amplitude, aging tests of stacked transducers for shock wave generation.
Sferruzza, Jean-Pierre; Birer, Alain; Chavrier, Françoise; Cathignol, Dominique
2002-10-01
New clinical concepts in lithotripsy demand small shock heads. Reducing the size of piezoelectric shock heads will be possible only if the pressure generated at the surface of each transducer can be increased so that the total pressure at the focus remains the same. To solve this problem, different solutions were proposed. For example, it has been demonstrated that piezocomposite material, as opposed to piezoceramic material, allows the generation of a higher surface pressure before breaking, mainly because radial modes are dramatically reduced. In addition, in a previous paper, we showed the feasibility of generating high-pressure pulse waves without increasing the transducer voltage by using sandwiched transducers, which are a stack of two or more transducers. Some discrepancies appeared, however, between the pressure measured at the surface of the front transducer and the arithmetic sum of the pressures generated by each transducer constituting the stack. In fact, development of such stacked transducers capable of generating surface pressures in the range of 2 to 5 MPa is very complex, which may explain why no aging tests have been reported in the literature thus far. In the first part of this paper, we theoretically determine the importance of the electroacoustical coupling between the two transducers on the generated surface pressure. We show that pressure losses due to these electroacoustical couplings are less than 5%. Experimental measurements done on a stacked transducer assembled and tightened in a castor oil-filled tank are in excellent accordance with the theoretical measurements. Using this assembly technique, it was possible to obtain, on average, out of four elements, a pressure of 7.5 MPa for the duration of 4 million shocks, which would allow the treatment of approximately 1000 patients.
Darwish, R A; Ashmawy, T A M
2011-10-01
During lambing the expression of an appropriate behavioural response from both the ewe and the lamb are extremely important to lamb survival. The aim of this study was to show the effect of length and difficulty of the birth process on the expression of maternal and neonatal behaviour with consequences on homeothermy and survival of the neonate lamb. Data were collected from 61 Finnish Landrace × Rahmani crossbred (second generation) primiparous ewes and their single born lambs. Based on the average length of parturition, the ewes were grouped into short birth (less than 32.5 min) and long birth (equal to or higher than 32.5 min) classes. The data recorded include maternal and neonatal behaviour, lamb body temperature over the first 3 days of life and survival rate of the neonate lamb during the first week after birth. Blood samples were also collected from the lamb, pre-suckling and at 24 and 72 h after birth. The obtained sera were assayed for thyroid hormones (T(3) and T(4)) that are associated with heat production. Ewes that had prolonged and difficult births did not show competent maternal behaviour compared to mothers with short and un-complicated deliveries, as they were slower to begin grooming their lambs after birth, spent less time licking their lambs, made less low-pitched vocalizations and nosing, were more likely to show rejection behaviour (10.34 % vs 5.4 %, P < 0.05), and were more likely to move away when the lamb sought the udder in an attempt to suck (acceptance rate, 55.5 % vs 64.79 %, P < 0.05). Similarly, lambs from a prolonged and difficult birth were significantly less vigorous after birth, as they had taken more time to stand, reach the udder and to suck successfully. These lambs had lower serum concentrations of T(3) and T(4), and they also had a reduced ability to maintain body temperature after birth. This effect persisted over the first 3 days of life and was associated with higher neonatal mortality in the first week after birth (11.54 %), compared to lambs from short and non-stressful birth processes (2.86 %, P < 0.01). From the present study, it can be concluded that, prolonged deliveries with birthing difficulty were one of the main causes of death of large, single-born lambs, as these complications cause the expression of inappropriate behavioural responses from both the ewe and neonatal lamb. Thus, interventions designed to reduce the incidence of prolonged parturitions are likely to be associated with better welfare for the ewe and the lamb and consequently improved lamb homeothermy and survival. Copyright © 2011 Elsevier Inc. All rights reserved.
Crack detection in fastener holes using surface acoustic wave
NASA Astrophysics Data System (ADS)
Bao, Xiao-Qi; Varadan, Vasundara V.; Varadan, Vijay K.
1995-05-01
This paper presents an investigation of the monitoring of cracks at the edge of fastener holes on plates using an ultrasonic pulse-echo technique. Our studies show that, if the surface of the plate surrounding the hold is free, an acoustic wave on the surface of the plate is able to detect the cracks located in an arc of 60 degree(s). When the inner surface of the hole is free, surface acoustic waves on the inner surface are alternate choices. For the case when all these surfaces are in tight contact with other parts, hence unavailable for mounting transducers, a particular type of Lamb wave mode is presented.
Ultrasonic wireless health monitoring
NASA Astrophysics Data System (ADS)
Petit, Lionel; Lefeuvre, Elie; Guyomar, Daniel; Richard, Claude; Guy, Philippe; Yuse, Kaori; Monnier, Thomas
2006-03-01
The integration of autonomous wireless elements in health monitoring network increases the reliability by suppressing power supplies and data transmission wiring. Micro-power piezoelectric generators are an attractive alternative to primary batteries which are limited by a finite amount of energy, a limited capacity retention and a short shelf life (few years). Our goal is to implement such an energy harvesting system for powering a single AWT (Autonomous Wireless Transmitter) using our SSH (Synchronized Switch Harvesting) method. Based on a non linear process of the piezoelement voltage, this SSH method optimizes the energy extraction from the mechanical vibrations. This AWT has two main functions : The generation of an identifier code by RF transmission to the central receiver and the Lamb wave generation for the health monitoring of the host structure. A damage index is derived from the variation between the transmitted wave spectrum and a reference spectrum. The same piezoelements are used for the energy harvesting function and the Lamb wave generation, thus reducing mass and cost. A micro-controller drives the energy balance and synchronizes the functions. Such an autonomous transmitter has been evaluated on a 300x50x2 mm 3 composite cantilever beam. Four 33x11x0.3 mm 3 piezoelements are used for the energy harvesting and for the wave lamb generation. A piezoelectric sensor is placed at the free end of the beam to track the transmitted Lamb wave. In this configuration, the needed energy for the RF emission is 0.1 mJ for a 1 byte-information and the Lamb wave emission requires less than 0.1mJ. The AWT can harvested an energy quantity of approximately 20 mJ (for a 1.5 Mpa lateral stress) with a 470 μF storage capacitor. This corresponds to a power density near to 6mW/cm 3. The experimental AWT energy abilities are presented and the damage detection process is discussed. Finally, some envisaged solutions are introduced for the implementation of the required data processing into an autonomous wireless receiver, in terms of reduction of the energy and memory costs.
Microhydraulic transducer technology for actuation and power generation
NASA Astrophysics Data System (ADS)
Hagood, Nesbitt W.; Roberts, David C.; Saggere, Laxminarayana; Breuer, Kenneth S.; Chen, Kuo-Shen; Carretero, Jorge A.; Li, Hanqing; Mlcak, Richard; Pulitzer, Seward W.; Schmidt, Martin A.; Spearing, S. Mark; Su, Yu-Hsuan
2000-06-01
The paper introduces a novel transducer technology, called the solid-state micro-hydraulic transducer, currently under development at MIT. The new technology is enabled through integration of micromachining technology, piezoelectrics, and microhydraulic concepts. These micro-hydraulic transducers are capable of bi-directional electromechanical energy conversion, i.e., they can operate as both an actuator that supplies high mechanical force in response to electrical input and an energy generator that transduces electrical energy from mechanical energy in the environment. These transducers are capable of transducing energy at very high specific power output in the order of 1 kW/kg, and thus, they have the potential to enable many novel applications. The concept, the design, and the potential applications of the transducers are presented. Present efforts towards the development of these transducers, and the challenges involved therein, are also discussed.
Poulter, James A; El-Sayed, Walid; Shore, Roger C; Kirkham, Jennifer; Inglehearn, Chris F; Mighell, Alan J
2014-01-01
The conventional approach to identifying the defective gene in a family with an inherited disease is to find the disease locus through family studies. However, the rapid development and decreasing cost of next generation sequencing facilitates a more direct approach. Here, we report the identification of a frameshift mutation in LAMB3 as a cause of dominant hypoplastic amelogenesis imperfecta (AI). Whole-exome sequencing of three affected family members and subsequent filtering of shared variants, without prior genetic linkage, sufficed to identify the pathogenic variant. Simultaneous analysis of multiple family members confirms segregation, enhancing the power to filter the genetic variation found and leading to rapid identification of the pathogenic variant. LAMB3 encodes a subunit of Laminin-5, one of a family of basement membrane proteins with essential functions in cell growth, movement and adhesion. Homozygous LAMB3 mutations cause junctional epidermolysis bullosa (JEB) and enamel defects are seen in JEB cases. However, to our knowledge, this is the first report of dominant AI due to a LAMB3 mutation in the absence of JEB.
Kocak, D; Ozel, M Z; Gogus, F; Hamilton, J F; Lewis, A C
2012-12-15
The grilling of meat may generate dangerous levels of mutagenic and carcinogenic nitrosamines (NAs). Meat and vegetable samples underwent a two-step solid-phase extraction before analysis by comprehensive gas chromatography with a nitrogen chemiluminescence detection system (GCxGC-NCD). The GCxGC-NCD method showed high selectivity, sensitivity and equimolarity in its response to six specific NAs. NA contamination of charcoal-grilled lamb at various stages of cooking and with various fat contents and also charcoal-grilled vegetables were investigated. The grilling of lamb on unready charcoal resulted in the formation of considerable quantities of NAs. Grilling lamb on properly prepared, ready charcoal resulted in an increase in total concentrations of six NAs from 0 to 4.51 μg kg(-1) over a period of 16 min. Increasing the fat content of the grilled lamb from 5% to 20% caused a modest increase in total concentrations of the six investigated NAs from 4.51 to 5.30 μg kg(-1). Copyright © 2012 Elsevier Ltd. All rights reserved.
Berg, E P; Neary, M K; Forrest, J C; Thomas, D L; Kauffman, R G
1996-11-01
Market weight lambs, average weight 52.5 kg (+/-6.1), were used to evaluate nontraditional live animal measurements as predictors of carcass composition. The sample population (n = 106) represented U.S. market lambs and transcended geographic location, breed, carcass weight, yield grade, and production system. Realtime ultrasonic (RU) measurements and bioelectrical impedance analysis (BIA) were used for development and evaluation of prediction equations for % boneless, closely trimmed primal cuts (BCTPC), weight or % of dissected lean tissue (TDL), and chemically derived weight or % fat-free lean (FFL). Longitudinal ultrasonic images were obtained parallel to the longissimus thoracis et lumborum (LTL), positioning the last costae in the center of the transducer head. Images were saved and fat and LTL depths were derived from printed images of the ultrasonic scans. Bioelectrical impedance analysis was administered via a four-terminal impedance plethysmograph operating at 800 microA at 50 kHz. Impedance measurements of whole-body resistance and reactance were recorded. Prediction equations including common linear measurements of live weight, heart girth, hindsaddle length, and shoulder height were also evaluated. All measurements were taken just before slaughter. Bioelectrical impedance measurements (as compared to RU and linear measurements) provided equations for %BCTPC, TDL, %TDL, FFL and %FFL with the highest R2 and lowest root mean square error. Even though BIA provided the best equations of the three methodologies tested, prediction of proportional yield (%BCTPC, %TDL, and %FFL) was marginal (R2 = .296, .551, and .551, respectively). Equations combining BIA, RU, and linear measurements greatly improved equations for prediction of proportional lean yield.
Method and apparatus for generating acoustic energy
Guerrero, Hector N.
2002-01-01
A method and apparatus for generating and emitting amplified coherent acoustic energy. A cylindrical transducer is mounted within a housing, the transducer having an acoustically open end and an acoustically closed end. The interior of the transducer is filled with an active medium which may include scattering nuclei. Excitation of the transducer produces radially directed acoustic energy in the active medium, which is converted by the dimensions of the transducer, the acoustically closed end thereof, and the scattering nuclei, to amplified coherent acoustic energy directed longitudinally within the transducer. The energy is emitted through the acoustically open end of the transducer. The emitted energy can be used for, among other things, effecting a chemical reaction or removing scale from the interior walls of containment vessels.
Dual-Use Transducer for Use with a Boundary-Stiffened Panel and Method of Using the Same
NASA Technical Reports Server (NTRS)
Schiller, Noah H. (Inventor); Cabell, Randolph H. (Inventor)
2011-01-01
A transducer for use with a boundary-stiffened panel has an inter-digitated electrode (IDE) and a piezoelectric wafer portion positioned therebetween. The IDE and/or the wafer portion are triangular, with one edge or side aligned with a boundary edge of the panel. The transducer generates and transmits an output force to the panel in response to an input voltage signal from a sensor, which can be another transducer as described above or an accelerometer. A controller can generate an output force signal in response to the input voltage signal to help cancel the input voltage signal. A method of using the transducer minimizes vibration in the panel by connecting multiple transducers around a perimeter thereof. Motion is measured at different portions of the panel, and a voltage signal determined from the motion is transmitted to the transducers to generate an output force at least partially cancelling or damping the motion.
Zhao, Youxuan; Li, Feilong; Cao, Peng; Liu, Yaolu; Zhang, Jianyu; Fu, Shaoyun; Zhang, Jun; Hu, Ning
2017-08-01
Since the identification of micro-cracks in engineering materials is very valuable in understanding the initial and slight changes in mechanical properties of materials under complex working environments, numerical simulations on the propagation of the low frequency S 0 Lamb wave in thin plates with randomly distributed micro-cracks were performed to study the behavior of nonlinear Lamb waves. The results showed that while the influence of the randomly distributed micro-cracks on the phase velocity of the low frequency S 0 fundamental waves could be neglected, significant ultrasonic nonlinear effects caused by the randomly distributed micro-cracks was discovered, which mainly presented as a second harmonic generation. By using a Monte Carlo simulation method, we found that the acoustic nonlinear parameter increased linearly with the micro-crack density and the size of micro-crack zone, and it was also related to the excitation frequency and friction coefficient of the micro-crack surfaces. In addition, it was found that the nonlinear effect of waves reflected by the micro-cracks was more noticeable than that of the transmitted waves. This study theoretically reveals that the low frequency S 0 mode of Lamb waves can be used as the fundamental waves to quantitatively identify micro-cracks in thin plates. Copyright © 2017 Elsevier B.V. All rights reserved.
Analysis of Critically Refracted Longitudinal and Lamb Waves for Stress Characterization
NASA Astrophysics Data System (ADS)
Pei, Ning
The global production of metal, in particular, steel and aluminum keeps increasing. This material is used with various fabrication processes, such as, welding, forging, and rolling that can induce stresses in the material that can subsequently impact product performance and cause phenomena such as cracking and corrosion. When investigating plate materials it is necessary to map both texture and stress under a range of loading conditions. To address these needs a wide range of both destructive and nondestructive tools have been used. One family of methods are those based on ultrasonic measurements that relate ultrasonic velocity to properties, in particular stress. Two particular challenges are faced which are the relative insensitivity of compression and shear waves to stress and that there are also other factors which can also change velocity and these are temperature, texture and grain size. This project focused on an analysis of ultrasonic velocity measurements and specifically ways to improve performance and capabilities for stress characterization. Two approaches were considered and are reported: the critically refracted ultrasonic longitudinal (LCR) wave and higher order Lamb waves. The LCR wave method was modelled and optimized based on the fact that the sensitivity between waves and stress can reach maximum when they propagate in the same direction. However, in reality this wave typically propagates at an angle to stress, which will decrease its sensitivity. This thesis reports a numerical model used to investigate the transducers parameters that can influence the directivity of the LCR wave and hence enable performance optimization when used for industrial applications. An orthogonal test method is used to study the transducer parameters which influence the LCR wave beams and this method provides a design tool that can be used to study and optimize multiple parameter experiments and identify which parameter or parameters are of most significance. The example considered simulation of the acoustic field in a 2-D water-steel model is obtained using a Spatial Fourier Analysis method. The significance of the effects of incident angle, the aperture and the center frequency of the transducer were studied. Results show that the aperture, the center frequency and the incident angle are the most important factors in controlling the directivity of the resulting LCR wave fields.
NASA Astrophysics Data System (ADS)
Zhang, Hongxiang; Tang, Zifan; Wang, Zhan; Pan, Shuting; Han, Ziyu; Sun, Chongling; Zhang, Menglun; Duan, Xuexin; Pang, Wei
2018-06-01
We report the nonlinear acoustic streaming effect and the fast manipulation of microparticles by microelectromechanical Lamb-wave resonators in a microliter droplet. The device, consisting of four Lamb-wave resonators on a silicon die, generates cylindrical traveling waves in a liquid and efficiently drives nine horizontal vortices within a 1 -μ l droplet; the performance of the device coincides with the numerical model prediction. Experimentally, the particles are enriched at the stagnation center of the main vortex on the free surface of the droplet in open space without microfluidic channels. In addition, the trajectories of the particles in the droplet can be controlled by the excitation power.
Standing wave performance test of IDT-SAW transducer prepared by silk-screen printing
NASA Astrophysics Data System (ADS)
Wang, Ziping; Jiang, Zhengxuan; Chen, Liangbin; Li, Yefei; Li, Meixia; Wang, Shaohan
2018-05-01
With the advantages of high performance and low loss, interdigital surface acoustic wave (IDT-SAW) transducers are widely used in the fields of nondestructive testing, communication and broadcasting. The production, performance and application of surface acoustic wave (SAW) actuators has become a research hotspot. Based on the basic principle of SAW, an IDT-SAW transducer is designed and fabricated using silk-screen printing in this work. The experiment results show that in terms of SAW performance, the fabricated IDT-SAW transducer can generate standing wave fields comparable to those generated using traditional fabrication methods. The resonant frequency response of the IDT-SAW transducer and SAW attenuation coefficient were obtained by experiments. It has provided a method to test the transducer sensing performance by using fabricated IDT-SAW transducer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinding, K.; Searfass, C.; Malarich, N.
2014-02-18
Applications for non-destructive evaluation and structural health monitoring of steam generators require ultrasonic transducers capable of withstanding the high temperatures of the pipes and heat exchangers. These applications require a strong coupling of the transducer to the heat exchanger’s complex geometry at the elevated temperatures. Our objective is to use spray-on piezo-electrics for depositing comb transducers onto the curved surfaces. This paper shows results for composite transducers such as lead zirconate titanate/ bismuth titanate and bismuth titanate/ lithium niobate. The comb transducers were prepared by precision laser ablation. The feasibility of producing second harmonic waves in rods with these spay-onmore » comb transducers was demonstrated and paves the way toward measuring material degradation early-on before crack initiation occurs.« less
Steam generator on-line efficiency monitor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R.K.; Kaya, A.; Keyes, M.A. IV
1987-08-04
This patent describes a system for automatically and continuously determining the efficiency of a combustion process in a fossil-fuel fired vapor generator for utilization by an automatic load control system that controls the distribution of a system load among a plurality of vapor generators, comprising: a first function generator, connected to an oxygen transducer for sensing the level of excess air in the flue gas, for generating a first signal indicative of the total air supplied for combustion in percent by weight; a second function generator, connected to a combustibles transducer for sensing the level of combustibles in the fluemore » gas, for generating a second signal indicative of the percent combustibles present in the flue gas; means for correcting the first signal, connected to the first and second function generators, when the oxygen transducer is of a type that operates at a temperature level sufficient to cause the unburned combustibles to react with the oxygen present in the flue gas; an ambient air temperature transducer for generating a third signal indicative of the temperature of the ambient air supplied to the vapor generator for combustion.« less
Development of Vibration-Based Piezoelectric Raindrop Energy Harvesting System
NASA Astrophysics Data System (ADS)
Wong, Chin Hong; Dahari, Zuraini
2017-03-01
The trend of finding new means to harvest energy has triggered numerous researches to explore the potential of raindrop energy harvesting. This paper presents an investigation on raindrop energy harvesting which compares the performance of polyvinylidene fluoride (PVDF) cantilever and bridge structure transducers and the development of a raindrop energy harvesting system. The parameters which contribute to the output voltage such as droplet size, droplets released at specific heights and dimensions of PVDF transducers are analyzed. Based on the experimental results, the outcomes have shown that the bridge structure transducer generated a higher voltage than the cantilever. Several dimensions have been tested and it was found that the 30 mm × 4 mm × 25 μm bridge structure transducer generated a relatively high AC open-circuit voltage, which is 4.22 V. The power generated by the bridge transducer is 18 μW across a load of 330 kΩ. The transducer is able to drive up a standard alternative current (AC) to direct current (DC) converter (full-wave bridge rectifier). It generated a DC voltage, V DC of 8.7 mV and 229 pW across a 330 kΩ resistor per drop. It is also capable to generate 9.3 nJ in 20 s from an actual rain event.
Delamination detection in smart composite beams using Lamb waves
NASA Astrophysics Data System (ADS)
Ip, Kim-Ho; Mai, Yiu-Wing
2004-06-01
This paper presents a feasibility study on using Lamb waves to detect and locate through-width delamination in fiber-reinforced plastic beams. An active diagnostic system is proposed for clamped-free specimens. It consists of a piezoelectric patch and an accelerometer both mounted near the support. Such a system can locate damage in an absolute sense, that is, a priori knowledge on the response from pristine specimens is not required. The fundamental anti-symmetric Lamb wave mode is chosen as the diagnostic wave. It is generated by applying a voltage in the form of sinusoidal bursts to the piezoelectric patch. The proposed system was applied to locate delaminations in some fabricated Kevlar/epoxy beam specimens. With an appropriate actuating frequency, distortions of waveforms due to boundary reflections can be reduced. Based on their arrival times and the known propagating speed of Lamb waves, the delaminations can be located. The errors associated with the predicted damage positions range from 4.5% to 8.5%.
Pérez-Fonseca, Agustín; Alcala-Canto, Yazmin; Salem, Abdelfattah Z M; Alberti-Navarro, Aldo B
2016-12-15
The current study aimed to determine the anti-Eimeria efficacy of an extract of grapefruit peels (GF) and commercial naringenin (NAR) in naturally-infected lambs, as well as the influence of these flavonoids on the oxidative status during ovine coccidiosis. Pharmacokinetic profiles were also determined. Extracts were administered per os to Eimeria naturally infected growing lambs during 90 consecutive days. The commercial anticoccidial drug toltrazuril (TTZ) was included in this trial as a standard. Twenty-four lambs were divided into four groups: NAR, lambs given a daily dose of 5mg of a commercial naringenin extract of 98% higher purity per kg body weight; GF, lambs that recived a daily dose of 5mg of ethanolic extract of grapefruit peels per kg body weight; TTZ, lambs treated with 20mg of toltrazuril/kg body weight on days 0 and 15 of the experiment; and CTRL, untreated lambs that received daily dose of 30ml of water. Daily doses of GF and NAR were dissolved in 30ml of water and orally given to animals; whereas toltrazuril was administered as a single dose of an undiluted suspension to lambs of the TTZ group. The CTRL group received 30ml of water; as well as the TTZ group for the period after the single dose administration. Fecal and serum samples were collected from all lambs. Anticoccidial efficacy was estimated by coprological techniques. Generation of nitric oxide levels and the antioxidant capacity of the experimental compounds were determined by the Griess and ABTS assays, respectively. The pharmacokinetic parameters of NAR and the GF extract were obtained. On day 30 post-ingestion, anticoccidial efficacy was 91.76% (NAR) and 89.65% (GF); whereas 99.63% of efficacy was achieved with TTZ 15days after treatment. NAR, GF and TTZ significantly reduced oxidative stress in infected animals. The mean daily weight gain for each group was 122g (NAR), 122g (GF), 143g (TTZ) and 98g (CTRL). Following the oral administration of NAR and GF, values in plasma approached maximum concentrations within 2.1 to 2.5h. In conclusion, the administration of NAR and the GF extract reduced Eimeria oocyst output, oxidative stress and promoted higher mean daily weight gains in infected lambs. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tian, Jiajun; Zhang, Qi; Han, Ming
2013-05-01
Fiber-optic ultrasonic transducers are an important component of an active ultrasonic testing system for structural health monitoring. Fiber-optic transducers have several advantages such as small size, light weight, and immunity to electromagnetic interference that make them much more attractive than the current available piezoelectric transducers, especially as embedded and permanent transducers in active ultrasonic testing for structural health monitoring. In this paper, a distributed fiber-optic laser-ultrasound generation based on the ghost-mode of tilted fiber Bragg gratings is studied. The influences of the laser power and laser pulse duration on the laser-ultrasound generation are investigated. The results of this paper are helpful to understand the working principle of this laser-ultrasound method and improve the ultrasonic generation efficiency.
NASA Astrophysics Data System (ADS)
Emadi, Tahereh Arezoo; Buchanan, Douglas A.
2014-03-01
A robust capacitive micromachined ultrasonic transducer has been developed. In this novel configuration, a stack of two deflectable membranes are suspended over a fixed bottom electrode. Similar to conventional capacitive ultrasonic transducers, a generated electrostatic force between the electrodes causes the membranes to deflect and vibrate. However, in this new configuration the transducer effective cavity height is reduced due to the deflection of two membranes. Therefore, the transducer spring constant is more susceptible to bias voltage, which in return reduces the required bias voltage. The transducers have been produced employing a MEMS sacrificial technique where two different membrane anchoring (curved- and flat- anchors) structures, with similar membrane radii were fabricated. Highly doped polysilicon was used as the membrane material. The resonant frequencies of the two transducers have been investigated. It was found that the transducers with curved membrane anchors exhibits a larger resonant frequency shift compared to the transducers with flat membranes for a given bias voltage. Comparison has been made between the spring constant of the flat membrane transducer and that of a conventional single membrane transducer. It is shown that the multiple moving membrane transducer exhibits a larger reduction in the spring constant compared to the conventional transducer, when driven with the same bias voltage. This results in a transducer with a higher power generation capability and sensitivity.
NASA Astrophysics Data System (ADS)
Li, Youping; Lu, Jinsong; Cheng, Jian; Yin, Yongzhen; Wang, Jianlan
2017-04-01
Based on the summaries of the rules about the vibration measurement for hydro-generator sets with respect to relevant standards, the key issues of the vibration measurement, such as measurement modes, the transducer selection are illustrated. In addition, the problems existing in vibration measurement are pointed out. The actual acquisition data of head cover vertical vibration respectively obtained by seismic transducer and eddy current transducer in site hydraulic turbine performance tests during the rising of the reservoir upstream level in a certain hydraulic power plant are compared. The difference of the data obtained by the two types of transducers and the potential reasons are presented. The application conditions of seismic transducer and eddy current transducer for hydro-generator set vibration measurement are given based on the analysis. Research subjects that should be focused on about the topic discussed in this paper are suggested.
The Dynamic Performance of Flexural Ultrasonic Transducers.
Feeney, Andrew; Kang, Lei; Rowlands, George; Dixon, Steve
2018-01-18
Flexural ultrasonic transducers are principally used as proximity sensors and for industrial metrology. Their operation relies on a piezoelectric ceramic to generate a flexing of a metallic membrane, which delivers the ultrasound signal. The performance of flexural ultrasonic transducers has been largely limited to excitation through a short voltage burst signal at a designated mechanical resonance frequency. However, a steady-state amplitude response is not generated instantaneously in a flexural ultrasonic transducer from a drive excitation signal, and differences in the drive characteristics between transmitting and receiving transducers can affect the measured response. This research investigates the dynamic performance of flexural ultrasonic transducers using acoustic microphone measurements and laser Doppler vibrometry, supported by a detailed mechanical analog model, in a process which has not before been applied to the flexural ultrasonic transducer. These techniques are employed to gain insights into the physics of their vibration behaviour, vital for the optimisation of industrial ultrasound systems.
The Dynamic Performance of Flexural Ultrasonic Transducers
Kang, Lei; Rowlands, George; Dixon, Steve
2018-01-01
Flexural ultrasonic transducers are principally used as proximity sensors and for industrial metrology. Their operation relies on a piezoelectric ceramic to generate a flexing of a metallic membrane, which delivers the ultrasound signal. The performance of flexural ultrasonic transducers has been largely limited to excitation through a short voltage burst signal at a designated mechanical resonance frequency. However, a steady-state amplitude response is not generated instantaneously in a flexural ultrasonic transducer from a drive excitation signal, and differences in the drive characteristics between transmitting and receiving transducers can affect the measured response. This research investigates the dynamic performance of flexural ultrasonic transducers using acoustic microphone measurements and laser Doppler vibrometry, supported by a detailed mechanical analog model, in a process which has not before been applied to the flexural ultrasonic transducer. These techniques are employed to gain insights into the physics of their vibration behaviour, vital for the optimisation of industrial ultrasound systems. PMID:29346297
Low Differential Pressure Generator
NASA Technical Reports Server (NTRS)
Stout, Stephen J. (Inventor); Deyoe, Richard T. (Inventor)
1997-01-01
A method and apparatus for evaluating low differential pressure transducers includes a pressure generator in the form of a piston-cylinder assembly having a piston that may be manually positioned precisely within the cylinder to change the volume and thus the pressure at respective sides of the piston. At one side of the piston the cylinder communicates with a first chamber and at the other side of the piston the cylinder communicates with a second chamber, the first and second chambers being formed within a common tank by a partition wall. The chambers each communicate with the transducer to be evaluated and a standard pre-calibrated transducer the transducers being connected fluidly in parallel so that a pressure differential between air in the two chambers resulting from movement of the piston within the cylinder is communicated to both the transducer to be evaluated and the standard transducer, and the outputs of the transducers is observed and recorded.
Topology optimized design of functionally graded piezoelectric ultrasonic transducers
NASA Astrophysics Data System (ADS)
Rubio, Wilfredo Montealegre; Buiochi, Flávio; Adamowski, Julio Cezar; Silva, Emílio C. N.
2010-01-01
This work presents a new approach to systematically design piezoelectric ultrasonic transducers based on Topology Optimization Method (TOM) and Functionally Graded Material (FGM) concepts. The main goal is to find the optimal material distribution of Functionally Graded Piezoelectric Ultrasonic Transducers, to achieve the following requirements: (i) the transducer must be designed to have a multi-modal or uni-modal frequency response, which defines the kind of generated acoustic wave, either short pulse or continuous wave, respectively; (ii) the transducer is required to oscillate in a thickness extensional mode or piston-like mode, aiming at acoustic wave generation applications. Two kinds of piezoelectric materials are mixed for producing the FGM transducer. Material type 1 represents a PZT-5A piezoelectric ceramic and material type 2 represents a PZT-5H piezoelectric ceramic. To illustrate the proposed method, two Functionally Graded Piezoelectric Ultrasonic Transducers are designed. The TOM has shown to be a useful tool for designing Functionally Graded Piezoelectric Ultrasonic Transducers with uni-modal or multi-modal dynamic behavior.
NASA Technical Reports Server (NTRS)
Paffenholz, Joseph; Fox, Jon W.; Gu, Xiaobai; Jewett, Greg S.; Datta, Subhendu K.
1990-01-01
Scattering of Rayleigh-Lamb waves by a normal surface-breaking crack in a plate has been studied both theoretically and experimentally. The two-dimensionality of the far field, generated by a ball impact source, is exploited to characterize the source function using a direct integration technique. The scattering of waves generated by this impact source by the crack is subsequently solved by employing a Green's function integral expression for the scattered field coupled with a finite element representation of the near field. It is shown that theoretical results of plate response, both in frequency and time, are similar to those obtained experimentally. Additionally, implication for practical applications are discussed.
MOSFET-based high voltage short pulse generator for ultrasonic transducer excitation
NASA Astrophysics Data System (ADS)
Hidayat, Darmawan; Setianto, Syafei, Nendi Suhendi; Wibawa, Bambang Mukti
2018-02-01
This paper presents the generation of a high-voltage short pulse for the excitation of high frequency ultrasonic transducers. This is highly required in the purpose of various ultrasonic-based evaluations, particularly when high resolution measurement is necessary. A high voltage (+760 V) DC voltage source was pulsated by an ultrafast switching MOSFET which was driven by a pulse generator circuit consisting of an astable multivibrator, a one-shot multivibrator with Schmitt trigger input and a high current MOSFET driver. The generated pulses excited a 200-kHz and a 1-MHz ultrasonic transducers and tested in the transmission mode propagation to evaluate the performances of the generated pulse. The test results showed the generator were able to produce negative spike pulses up to -760 V voltage with the shortest time-width of 107.1 nanosecond. The transmission-received ultrasonic waves show frequency oscillation at 200 and 961 kHz and their amplitudes varied with the voltage of excitation pulse. These results conclude that the developed pulse generator is applicable to excite transducer for the generation of high frequency ultrasonic waves.
Actively generated noise liquid flowmeter.
Tanisawa, S; Hirose, H; Yoshihisa, N
1994-01-01
A new noise flowmeter with two transducers has been tested experimentally in water. It detects the noises generated by the interaction between artificially introduced air bubbles and a built-in obstacle with a downstream transducer, and differentiates them from the external noises detected by the upstream transducer in a pipe. The system includes processing instrumentation with functions such as averaging and difference-operating for reduction of external noise effects.
Baseline-free damage detection in composite plates based on the reciprocity principle
NASA Astrophysics Data System (ADS)
Huang, Liping; Zeng, Liang; Lin, Jing
2018-01-01
Lamb wave based damage detection techniques have been widely used in composite structures. In particular, these techniques usually rely on reference signals, which are significantly influenced by the operational and environmental conditions. To solve this issue, this paper presents a baseline-free damage inspection method based on the reciprocity principle. If a localized nonlinear scatterer exists along the wave path, the reciprocity breaks down. Through estimating the loss of reciprocity, the delamination could be detected. A reciprocity index (RI), which compares the discrepancy between the signal received in transducer B when emitting from transducer A and the signal received in A when the same source is located in B, is established to quantitatively analyze the reciprocity. Experimental results show that the RI value of a damaged path is much higher than that of a healthy path. In addition, the effects of the parameters of excitation signal (i.e., central frequency and bandwidth) and the position of delamination on the RI value are discussed. Furthermore, a RI based probabilistic imaging algorithm is proposed for detecting delamination damage of composite plates without reference signals. Finally, the effectiveness of this baseline-free damage detection method is validated by an experimental example.
Optimal sensor placement for active guided wave interrogation of complex metallic components
NASA Astrophysics Data System (ADS)
Coelho, Clyde K.; Kim, Seung Bum; Chattopadhyay, Aditi
2011-04-01
With research in structural health monitoring (SHM) moving towards increasingly complex structures for damage interrogation, the placement of sensors is becoming a key issue in the performance of the damage detection methodologies. For ultrasonic wave based approaches, this is especially important because of the sensitivity of the travelling Lamb waves to material properties, geometry and boundary conditions that may obscure the presence of damage if they are not taken into account during sensor placement. The framework proposed in this paper defines a sensing region for a pair of piezoelectric transducers in a pitch-catch damage detection approach by taking into account the material attenuation and probability of false alarm. Using information about the region interrogated by a sensoractuator pair, a simulated annealing optimization framework was implemented in order to place sensors on complex metallic geometries such that a selected minimum damage type and size could be detected with an acceptable probability of false alarm anywhere on the structure. This approach was demonstrated on a lug joint to detect a crack and on a large Naval SHM test bed and resulted in a placement of sensors that was able to interrogate all parts of the structure using the minimum number of transducers.
Physics of thermo-acoustic sound generation
NASA Astrophysics Data System (ADS)
Daschewski, M.; Boehm, R.; Prager, J.; Kreutzbruck, M.; Harrer, A.
2013-09-01
We present a generalized analytical model of thermo-acoustic sound generation based on the analysis of thermally induced energy density fluctuations and their propagation into the adjacent matter. The model provides exact analytical prediction of the sound pressure generated in fluids and solids; consequently, it can be applied to arbitrary thermal power sources such as thermophones, plasma firings, laser beams, and chemical reactions. Unlike existing approaches, our description also includes acoustic near-field effects and sound-field attenuation. Analytical results are compared with measurements of sound pressures generated by thermo-acoustic transducers in air for frequencies up to 1 MHz. The tested transducers consist of titanium and indium tin oxide coatings on quartz glass and polycarbonate substrates. The model reveals that thermo-acoustic efficiency increases linearly with the supplied thermal power and quadratically with thermal excitation frequency. Comparison of the efficiency of our thermo-acoustic transducers with those of piezoelectric-based airborne ultrasound transducers using impulse excitation showed comparable sound pressure values. The present results show that thermo-acoustic transducers can be applied as broadband, non-resonant, high-performance ultrasound sources.
Absolute calibration technique for broadband ultrasonic transducers
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, John H. (Inventor)
1994-01-01
Calibrating an ultrasonic transducer can be performed with a reduced number of calculations and testing. A wide-band pulser is connected to an ultrasonic transducer under test to generate ultrasonic waves in a liquid. A single frequency is transmitted to the electrostatic acoustic transducer (ESAT) and the voltage change produced is monitored. Then a broadband ultrasonic pulse is generated by the ultrasonic transducer and received by the ESAT. The output of the ESAT is amplified and input to a digitized oscilloscope for fast Fourier transform. The resulting plot is normalized with the monitored signal from the single frequency pulse. The plot is then corrected for characteristics of the membrane and diffraction effects. The transfer function of the final plot is determined. The transfer function gives the final sensitivity of the ultrasonic transducer as a function of frequency. The advantage of the system is the speed of calibrating the transducer by a reduced number of measurements and removal of the membrane and diffraction effects.
Opto-acoustic transducer for medical applications
Benett, William; Celliers, Peter; Da Silva, Luiz; Glinsky, Michael; London, Richard; Maitland, Duncan; Matthews, Dennis; Krulevich, Peter; Lee, Abraham
2002-01-01
This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control.
Opto-acoustic transducer for medical applications
Benett, William; Celliers, Peter; Da Silva, Luiz; Glinsky, Michael; London, Richard; Maitland, Duncan; Matthews, Dennis; Krulevich, Peter; Lee, Abraham
1999-01-01
This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control.
Opto-acoustic transducer for medical applications
Benett, W.; Celliers, P.; Da Silva, L.; Glinsky, M.; London, R.; Maitland, D.; Matthews, D.; Krulevich, P.; Lee, A.
1999-08-31
This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control. 7 figs.
NASA Astrophysics Data System (ADS)
Kreger, Stephen T.; Sang, Alex K.; Garg, Naman; Michel, Julia
2013-05-01
Fiber-optic ultrasonic transducers are an important component of an active ultrasonic testing system for structural health monitoring. Fiber-optic transducers have several advantages such as small size, light weight, and immunity to electromagnetic interference that make them much more attractive than the current available piezoelectric transducers, especially as embedded and permanent transducers in active ultrasonic testing for structural health monitoring. In this paper, a distributed fiber-optic laser-ultrasound generation based on the ghost-mode of tilted fiber Bragg gratings is studied. The influences of the laser power and laser pulse duration on the laser-ultrasound generation are investigated. The results of this paper are helpful to understand the working principle of this laser-ultrasound method and improve the ultrasonic generation efficiency.
Silicon wafer temperature monitoring using all-fiber laser ultrasonics
NASA Astrophysics Data System (ADS)
Alcoz, Jorge J.; Duffer, Charles E.
1998-03-01
Laser-ultrasonics is a very attractive technique for in-line process control in the semiconductor industry as it is compatible with the clean room environment and offers the capability to inspect parts at high-temperature. We describe measurements of the velocity of laser-generated Lamb waves in silicon wafers as a function of temperature using fiber- optic laser delivery and all-fiber interferometric sensing. Fundamental anti-symmetric Lamb-wave modes were generated in 5 inches < 111 > silicon wafers using a Nd:YAG laser coupled to a large-core multimode fiber. Generation was also performed using an array of sources created with a diffraction grating. For detection a compact fiber-optic sensor was used which is well suited for industrial environments as it is compact, rugged, stable, and low-cost. The wafers were heated up to 1000 degrees C and the temperature correlated with ultrasonic velocity measurements.
Multifrequency ultrasound transducers for conformal interstitial thermal therapy.
Chopra, Rajiv; Luginbuhl, Chris; Foster, F Stuart; Bronskill, Michael J
2003-07-01
Control over the pattern of thermal damage generated by interstitial ultrasound heating applicators can be enhanced by changing the ultrasound frequency during heating. The ability to change transmission frequency from a single transducer through the use of high impedance front layers was investigated in this study. The transmission spectrum of multifrequency transducers was calculated using the KLM equivalent circuit model and verified with experimental measurements on prototype transducers. The addition of a quarter-wavelength thick PZT (unpoled) front layer enabled the transmission of ultrasound at two discrete frequencies, 4.7 and 9.7 MHz, from a transducer with an original resonant frequency of 8.4 MHz. Three frequency transmission at 3.3, 8.4, and 10.8 MHz was possible for a transducer with a half-wavelength thick front layer. Calculations of the predicted thermal lesion size at each transmission frequency indicated that the depth of thermal lesion could be varied by a factor of 1.6 for the quarter-wavelength front layer. Heating experiments performed in excised liver tissue with a dual-frequency applicator confirmed this ability to control the shape of thermal lesions during heating to generate a desired geometry. Practical interstitial designs that enable the generation of shaped thermal lesions are feasible.
Numerical and experimental study of Lamb wave propagation in a two-dimensional acoustic black hole
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Shiling; Shen, Zhonghua, E-mail: shenzh@njust.edu.cn; Lomonosov, Alexey M.
2016-06-07
The propagation of laser-generated Lamb waves in a two-dimensional acoustic black-hole structure was studied numerically and experimentally. The geometrical acoustic theory has been applied to calculate the beam trajectories in the region of the acoustic black hole. The finite element method was also used to study the time evolution of propagating waves. An optical system based on the laser-Doppler vibration method was assembled. The effect of the focusing wave and the reduction in wave speed of the acoustic black hole has been validated.
Environmental control system transducer development study
NASA Technical Reports Server (NTRS)
Brudnicki, M. J.
1973-01-01
A failure evaluation of the transducers used in the environmental control systems of the Apollo command service module, lunar module, and portable life support system is presented in matrix form for several generic categories of transducers to enable identification of chronic failure modes. Transducer vendors were contacted and asked to supply detailed information. The evaluation data generated for each category of transducer were compiled and published in failure design evaluation reports. The evaluation reports also present a review of the failure and design data for the transducers and suggest both design criteria to improve reliability of the transducers and, where necessary, design concepts for required redesign of the transducers. Remedial designs were implemented on a family of pressure transducers and on the oxygen flow transducer. The design concepts were subjected to analysis, breadboard fabrication, and verification testing.
Parameters influencing focalization spot in time reversal of acoustic waves
NASA Astrophysics Data System (ADS)
Zophoniasson, Harald; Bolzmacher, Christian; Hafez, Moustafa
2015-05-01
Time reversal is an approach that can be used to focus acoustic waves in a particular location on a surface, allowing a multitouch tactile feedback interaction. The spatial resolution in this case depends on several parameters, such as geometrical parameters, frequency used and material properties, described by the Lamb wave theory. This paper highlights the impact of frequency, geometrical parameters such as plate thickness and transducer's surface on the focused spot dimensions. In this paper a study of the influence of the plate's thickness and the frequency bandwidth used in the focusing process is presented. It is also shown that the dimension of the piezoelectric diaphragms used has little influence on the spatial resolution. Resonant behavior of the plate and its implication on focus point dimension and focalization contrast were investigated.
A micro-machined source transducer for a parametric array in air.
Lee, Haksue; Kang, Daesil; Moon, Wonkyu
2009-04-01
Parametric array applications in air, such as highly directional parametric loudspeaker systems, usually rely on large radiators to generate the high-intensity primary beams required for nonlinear interactions. However, a conventional transducer, as a primary wave projector, requires a great deal of electrical power because its electroacoustic efficiency is very low due to the large characteristic mechanical impedance in air. The feasibility of a micro-machined ultrasonic transducer as an efficient finite-amplitude wave projector was studied. A piezoelectric micro-machined ultrasonic transducer array consisting of lead zirconate titanate uni-morph elements was designed and fabricated for this purpose. Theoretical and experimental evaluations showed that a micro-machined ultrasonic transducer array can be used as an efficient source transducer for a parametric array in air. The beam patterns and propagation curves of the difference frequency wave and the primary wave generated by the micro-machined ultrasonic transducer array were measured. Although the theoretical results were based on ideal parametric array models, the theoretical data explained the experimental results reasonably well. These experiments demonstrated the potential of micro-machined primary wave projector.
NASA Astrophysics Data System (ADS)
Wang, Qingdong; Li, Yuzhi; Ma, Qingyu; Guo, Gepu; Tu, Juan; Zhang, Dong
2018-01-01
In order to improve the capability of particle trapping close to the source plane, theoretical and experimental studies on near-field multiple traps of paraxial acoustic vortices (AVs) with a strengthened acoustic gradient force (AGF) generated by a sector transducer array were conducted. By applying the integration of point source radiation, numerical simulations for the acoustic fields generated by the sector transducer array were conducted and compared with those produced by the circular transducer array. It was proved that strengthened AGFs of near-field multiple AVs with higher peak pressures and smaller vortex radii could be produced by the sector transducer array with a small topological charge. The axial distributions of the equivalent potential gradient indicated that the AGFs of paraxial AVs in the near field were much higher than those in the far field, and the distances at the near-field vortex antinodes were also proved to be the ideal trapping positions with relatively higher AGFs. With the established 8-channel AV generation system, theoretical studies were also verified by the experimental measurements of pressure and phase for AVs with various topological charges. The formation of near-field multiple paraxial AVs was verified by the cross-sectional circular pressure distributions with perfect phase spirals around central pressure nulls, and was also proved by the vortex nodes and antinodes along the center axis. The favorable results demonstrated the feasibility of generating near-field multiple traps of paraxial AVs with strengthened AGF using the sector transducer array, and suggested the potential applications of close-range particle trapping in biomedical engineering.
NASA Astrophysics Data System (ADS)
Uchida, Takeyoshi; Kikuchi, Tsuneo
2013-07-01
Ultrasonic power is one of the key quantities closely related to the safety of medical ultrasonic equipment. An ultrasonic power standard is required for establishment of safety. Generally, an ultrasonic power standard below approximately 20 W is established by the radiation force balance (RFB) method as the most accurate measurement method. However, RFB is not suitable for high ultrasonic power because of thermal damage to the absorbing target. Consequently, an alternative method to RFB is required. We have been developing a measurement technique for high ultrasonic power by the calorimetric method. In this study, we examined the effect of heat generation of an ultrasound transducer on ultrasonic power measured by the calorimetric method. As a result, an excessively high ultrasonic power was measured owing to the effect of heat generation from internal loss in the transducer. A reference ultrasound transducer with low heat generation is required for a high ultrasonic power standard established by the calorimetric method.
NASA Astrophysics Data System (ADS)
Qiu, Lei; Yuan, Shenfang; Shi, Xiaoling; Huang, Tianxiang
2012-07-01
Piezoelectric transducer (PZT) and Lamb wave based structural health monitoring (SHM) method have been widely studied for on-line SHM of high-performance structures. To monitor large-scale structures, a dense PZTs array is required. In order to improve the placement efficiency and reduce the wire burden of the PZTs array, the concept of the piezoelectric transducers layer (PSL) was proposed. The PSL consists of PZTs, a flexible interlayer with printed wires and signal input/output interface. For on-line SHM on real aircraft structures, there are two main issues on electromagnetic interference and connection reliability of the PSL. To address the issues, an electromagnetic shielding design method of the PSL to reduce spatial electromagnetic noise and crosstalk is proposed and a combined welding-cementation process based connection reliability design method is proposed to enhance the connection reliability between the PZTs and the flexible interlayer. Two experiments on electromagnetic interference suppression are performed to validate the shielding design of the PSL. The experimental results show that the amplitudes of the spatial electromagnetic noise and crosstalk output from the shielded PSL developed by this paper are - 15 dB and - 25 dB lower than those of the ordinary PSL, respectively. Other two experiments on temperature durability ( - 55 °C-80 °C ) and strength durability (160-1600μɛ, one million load cycles) are applied to the PSL to validate the connection reliability. The low repeatability errors (less than 3% and less than 5%, respectively) indicate that the developed PSL is of high connection reliability and long fatigue life.
Translating science into the next generation meat quality program for Australian lamb.
Pethick, D W; Ball, A J; Banks, R G; Gardner, G E; Rowe, J B; Jacob, R H
2014-02-01
This paper introduces a series of papers in the form of a special edition that reports phenotypic analyses done in parallel with genotypic analyses for the Australian Sheep Industry Cooperative Research Centre (Sheep CRC) using data generated from the information nucleus flock (INF). This has allowed new knowledge to be gained of the genetic, environment and management factors that impact on the carcase and eating quality, visual appeal, odour and health attributes of Australian lamb meat. The research described involved close collaboration with commercial partners across the supply chain in the sire breeding as well as the meat processing industries. This approach has enabled timely delivery and adoption of research results to industry in an unprecedented way and provides a good model for future research. © 2013.
NASA Astrophysics Data System (ADS)
Ozevin, Didem; Greve, David W.; Oppenheim, Irving J.; Pessiki, Stephen
2005-05-01
We describe the design, fabrication, testing and application (in structural experiments) of our 2004 (second generation) MEMS device, designed for acoustic emission sensing based upon experiments with our 2002 (first generation) device. Both devices feature a suite of resonant-type transducers in the frequency range between 100 kHz and 1 MHz. The 2002 device was designed to operate in an evacuated housing because of high squeeze film damping, as confirmed in our earlier experiments. In additional studies involving the 2002 device, experimental simulation of acoustic emissions in a steel plate, using pencil lead break or ball impact loading, showed that the transducers in the frequency range of 100 kHz-500 kHz presented clearer output signals than the transducers with frequencies higher than 500 kHz. Using the knowledge gained from the 2002 device, we designed and fabricated our second generation device in 2004 using the multi-user polysilicon surface micromachining (MUMPs) process. The 2004 device has 7 independent capacitive type transducers, compared to 18 independent transducers in the 2002 device, including 6 piston type transducers in the frequency range of 100 kHz to 500 kHz and 1 piston type transducer at 1 MHz to capture high frequency information. Piston type transducers developed in our research have two uncoupled modes so that twofold information can be acquired from a single transducer. In addition, the piston shape helps to reduce residual stress effect of surface micromachining process. The center to center distance between etch holes in the vibrating plate was reduced from 30 μm to 13 μm, in order to reduce squeeze film damping. As a result, the Q factor under atmospheric pressure for the 100 kHz transducer was increased to 2.37 from 0.18, and therefore the vacuum housing has been eliminated from the 2004 device. Sensitivities of transducers were also increased, by enlarging transducer area, in order to capture significant small amplitude acoustic emission events. The average individual transducer area in the 2004 device was increased to 6.97 mm2 as compared to 2.51 mm2 in the 2002 device. In this paper, we report the new experimental results on the characterization of the 2004 device and compare them with analytical results. We show improvements in sensitivity as measured by capacitance and as measured by pencil lead break experiments. Improvement in damping is also evaluated by admittance measurement in atmosphere. Pencil lead break experiments also show that transducers can operate in atmospheric pressure. Finally, we apply the device to acoustic emission experiments on crack propagation in a steel beam specimen, precracked in fatigue, in a four-point bending test.
Moulin, Emmanuel; Grondel, Sébastien; Assaad, Jamal; Duquenne, Laurent
2008-12-01
The work described in this paper is intended to present a simple and efficient way of modeling a full Lamb wave emission and reception system. The emitter behavior and the Lamb wave generation are predicted using a two-dimensional (2D) hybrid finite element-normal mode expansion model. Then the receiver electrical response is obtained from a finite element computation with prescribed displacements. A numerical correction is applied to the 2D results in order to account for the in-plane radiation divergence caused by the finite length of the emitter. The advantage of this modular approach is that realistic configurations can be simulated without performing cumbersome modeling and time-consuming computations. It also provides insight into the physical interpretation of the results. A good agreement is obtained between predicted and measured signals. The range of application of the method is discussed.
Instrument For Simulation Of Piezoelectric Transducers
NASA Technical Reports Server (NTRS)
Mcnichol, Randal S.
1996-01-01
Electronic instrument designed to simulate dynamic output of integrated-circuit piezoelectric acceleration or pressure transducer. Operates in conjunction with external signal-conditioning circuit, generating square-wave signal of known amplitude for use in calibrating signal-conditioning circuit. Instrument also useful as special-purpose square-wave generator in other applications.
Aggarwal, Saurabh; Gross, Christine M.; Kumar, Sanjiv; Datar, Sanjeev; Oishi, Peter; Kalka, Gokhan; Schreiber, Christian; Fratz, Sohrab; Fineman, Jeffrey R.; Black, Stephen M.
2012-01-01
Pulmonary vasodilation is mediated through the activation of protein kinase G (PKG) via a signaling pathway involving nitric oxide (NO), natriuretic peptides (NP), and cyclic guanosine monophosphate (cGMP). In pulmonary hypertension secondary to congenital heart disease, this pathway is endogenously activated by an early vascular upregulation of NO and increased myocardial B-type NP expression and release. In the treatment of pulmonary hypertension, this pathway is exogenously activated using inhaled NO or other pharmacological agents. Despite this activation of cGMP, vascular dysfunction is present, suggesting that NO-cGMP independent mechanisms are involved and were the focus of this study. Exposure of pulmonary artery endothelial or smooth muscle cells to the NO donor, Spermine NONOate (SpNONOate), increased peroxynitrite (ONOO−) generation and PKG-1α nitration, while PKG-1α activity was decreased. These changes were prevented by superoxide dismutase (SOD) or manganese(III)tetrakis(1-methyl-4-pyridyl)porphyrin (MnTMPyP) and mimicked by the ONOO− donor, 3-morpholinosydnonimine N-ethylcarbamide (SIN-1). Peripheral lung extracts from 4-week old lambs with increased pulmonary blood flow and pulmonary hypertension (Shunt lambs with endogenous activation of cGMP) or juvenile lambs treated with inhaled NO for 24h (with exogenous activation of cGMP) revealed increased ONOO− levels, elevated PKG-1α nitration, and decreased kinase activity without changes in PKG-1α protein levels. However, in Shunt lambs treated with L-arginine or lambs administered polyethylene glycol conjugated-SOD (PEG-SOD) during inhaled NO exposure, ONOO− and PKG-1α nitration were diminished and kinase activity was preserved. Together our data reveal that vascular dysfunction can occur, despite elevated levels of cGMP, due to PKG-1α nitration and subsequent attenuation of activity. PMID:21351102
Lakshminrusimha, Satyan; Porta, Nicolas F. M.; Farrow, Kathryn N.; Chen, Bernadette; Gugino, Sylvia F.; Kumar, Vasanth H.; Russell, James A.; Steinhorn, Robin H.
2009-01-01
Prostacyclin is a pulmonary vasodilator and is produced by prostacyclin synthase and stimulates adenylate cyclase (AC) via the prostacyclin receptor (IP) to produce cAMP. Forskolin is a direct stimulant of AC. Phosphodiesterase 3 hydrolyzes cAMP and is inhibited by milrinone. Objective To characterize the prostacyclin-AC-cAMP pathway in the ovine ductal ligation model of persistent pulmonary hypertension of the newborn (PPHN). Setting University-based laboratory animal facility. Subjects Lambs delivered to time-dated pregnant ewes. Interventions Fifth generation pulmonary arteries (PA) and lung parenchyma were isolated from control fetal lambs (n = 8) and fetal lambs with PPHN induced by antenatal ductal ligation (n = 9). We studied relaxation responses to various agonists (milrinone, forskolin, prostacyclin, and iloprost, a prostacyclin analog) that increase cAMP in PA after half-maximal constriction with norepinephrine and pretreatment with propranolol ± indo-methacin. Lung protein levels of prostacyclin synthase, IP, AC2, and phosphodiesterase 3A were analyzed by Western blot and cAMP by enzyme-linked immunoassay. Main Results Milrinone relaxed control and PPHN PA and pretreatment with indomethacin significantly impaired this response. Relaxation to milrinone, prostacyclin, and iloprost were significantly impaired in PA from PPHN lambs. Pretreatment with milrinone markedly enhanced relaxation to prostacyclin and iloprost in PPHN PA, similar to relaxation in control PA. Relaxation to forskolin was similar in control and PPHN PAs indicating normal AC activity. Protein levels of prostacyclin synthase and IP were decreased in PPHN lungs compared with control, but AC2, cAMP, and phosphodiesterase 3A remained unchanged. Conclusions Prostacyclin and iloprost are dilators of PAs from PPHN lambs and their effect is enhanced by milrinone. This combination therapy may be an effective strategy in the management of patients with PPHN. PMID:19057444
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J.M. Jr.; Stormshak, F.; Thompson, J.M.
This study determined whether chronic exposure of female lambs to the electric and magnetic fields (EMF) of a high voltage transmission line can alter pineal secretion of melatonin and the normal occurrence of puberty. Twenty female Suffolk lambs were assigned randomly in equal numbers to a control and a treatment group. Treatment from 2 to 10 mo of age consisted of continuous exposure within the electrical environment of a 500-kV transmission line (mean electric field 6 kV/m, mean magnetic field 40 mG). Treated lambs were penned directly beneath the transmission line; control lambs were maintained in a pen of similarmore » construction 229 m from the line where EMF were at ambient levels (mean electric field < 10 V/m, mean magnetic field < 0.3 mG). Melatonin was analyzed by RIA in serum of blood samples collected at 0.5-3-h intervals over eight 48-h periods. To assess attainment of puberty, serum concentrations of progesterone were determined by RIA from blood samples collected twice weekly beginning at 19 wk of age. Concentrations of circulating melatonin in control and treated lambs were low during daylight hours and increased during nighttime hours. The characteristic pattern of melatonin secretion during nighttime (amplitude, phase, and duration) did not differ between control and treatment groups. Age at puberty and number of subsequent estrous cycles also did not differ between groups. These data suggest that chronic exposure of developing female sheep to 60-Hz environmental EMF does not affect the mechanisms underlying the generation of the circadian pattern of melatonin secretion or the mechanisms involved in the onset of reproductive activity.« less
Casellas, J; Bach, R
2012-06-01
Lambing interval is a relevant reproductive indicator for sheep populations under continuous mating systems, although there is a shortage of selection programs accounting for this trait in the sheep industry. Both the historical assumption of small genetic background and its unorthodox distribution pattern have limited its implementation as a breeding objective. In this manuscript, statistical performances of 3 alternative parametrizations [i.e., symmetric Gaussian mixed linear (GML) model, skew-Gaussian mixed linear (SGML) model, and piecewise Weibull proportional hazard (PWPH) model] have been compared to elucidate the preferred methodology to handle lambing interval data. More specifically, flock-by-flock analyses were performed on 31,986 lambing interval records (257.3 ± 0.2 d) from 6 purebred Ripollesa flocks. Model performances were compared in terms of deviance information criterion (DIC) and Bayes factor (BF). For all flocks, PWPH models were clearly preferred; they generated a reduction of 1,900 or more DIC units and provided BF estimates larger than 100 (i.e., PWPH models against linear models). These differences were reduced when comparing PWPH models with different number of change points for the baseline hazard function. In 4 flocks, only 2 change points were required to minimize the DIC, whereas 4 and 6 change points were needed for the 2 remaining flocks. These differences demonstrated a remarkable degree of heterogeneity across sheep flocks that must be properly accounted for in genetic evaluation models to avoid statistical biases and suboptimal genetic trends. Within this context, all 6 Ripollesa flocks revealed substantial genetic background for lambing interval with heritabilities ranging between 0.13 and 0.19. This study provides the first evidence of the suitability of PWPH models for lambing interval analysis, clearly discarding previous parametrizations focused on mixed linear models.
Ultrasonic Leak Detection System
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor); Moerk, J. Steven (Inventor)
1998-01-01
A system for detecting ultrasonic vibrations. such as those generated by a small leak in a pressurized container. vessel. pipe. or the like. comprises an ultrasonic transducer assembly and a processing circuit for converting transducer signals into an audio frequency range signal. The audio frequency range signal can be used to drive a pair of headphones worn by an operator. A diode rectifier based mixing circuit provides a simple, inexpensive way to mix the transducer signal with a square wave signal generated by an oscillator, and thereby generate the audio frequency signal. The sensitivity of the system is greatly increased through proper selection and matching of the system components. and the use of noise rejection filters and elements. In addition, a parabolic collecting horn is preferably employed which is mounted on the transducer assembly housing. The collecting horn increases sensitivity of the system by amplifying the received signals. and provides directionality which facilitates easier location of an ultrasonic vibration source.
Acoustic emission testing of composite vessels under sustained loading
NASA Technical Reports Server (NTRS)
Lark, R. F.; Moorhead, P. E.
1978-01-01
Acoustic emissions (AE) generated from Kevlar 49/epoxy composite pressure vessels subjected to sustained load-to-failure tests were studied. Data from two different transducer locations on the vessels were compared. It was found that AE from vessel wall-mounted transducers showed a wide variance from those for identical vessels subjected to the same pressure loading. Emissions from boss-mounted transducers did, however, yield values that were relatively consistent. It appears that the signals from the boss-mounted transducers represent an integrated average of the emissions generated by fibers fracturing during the vessel tests. The AE from boss-mounted transducers were also independent of time for vessel failure. This suggests that a similar number of fiber fractures must occur prior to initiation of vessel failure. These studies indicate a potential for developing an AE test procedure for predicting the residual service life or integrity of composite vessels.
Ultrasound pressure distributions generated by high frequency transducers in large reactors.
Leong, Thomas; Coventry, Michael; Swiergon, Piotr; Knoerzer, Kai; Juliano, Pablo
2015-11-01
The performance of an ultrasound reactor chamber relies on the sound pressure level achieved throughout the system. The active volume of a high frequency ultrasound chamber can be determined by the sound pressure penetration and distribution provided by the transducers. This work evaluated the sound pressure levels and uniformity achieved in water by selected commercial scale high frequency plate transducers without and with reflector plates. Sound pressure produced by ultrasonic plate transducers vertically operating at frequencies of 400 kHz (120 W) and 2 MHz (128 W) was characterized with hydrophones in a 2 m long chamber and their effective operating distance across the chamber's vertical cross section was determined. The 2 MHz transducer produced the highest pressure amplitude near the transducer surface, with a sharp decline of approximately 40% of the sound pressure occurring in the range between 55 and 155 mm from the transducer. The placement of a reflector plate 500 mm from the surface of the transducer was shown to improve the sound pressure uniformity of 2 MHz ultrasound. Ultrasound at 400 kHz was found to penetrate the fluid up to 2 m without significant losses. Furthermore, 400 kHz ultrasound generated a more uniform sound pressure distribution regardless of the presence or absence of a reflector plate. The choice of the transducer distance to the opposite reactor wall therefore depends on the transducer plate frequency selected. Based on pressure measurements in water, large scale 400 kHz reactor designs can consider larger transducer distance to opposite wall and larger active cross-section, and therefore can reach higher volumes than when using 2 MHz transducer plates. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging
NASA Technical Reports Server (NTRS)
Seale, Michael D.; Madaras, Eric I.
2004-01-01
The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.
Transmit beamforming for optimal second-harmonic generation.
Hoilund-Kaupang, Halvard; Masoy, Svein-Erik
2011-08-01
A simulation study of transmit ultrasound beams from several transducer configurations is conducted to compare second-harmonic imaging at 3.5 MHz and 11 MHz. Second- harmonic generation and the ability to suppress near field echoes are compared. Each transducer configuration is defined by a chosen f-number and focal depth, and the transmit pressure is estimated to not exceed a mechanical index of 1.2. The medium resembles homogeneous muscle tissue with nonlinear elasticity and power-law attenuation. To improve computational efficiency, the KZK equation is utilized, and all transducers are circular-symmetric. Previous literature shows that second-harmonic generation is proportional to the square of the transmit pressure, and that transducer configurations with different transmit frequencies, but equal aperture and focal depth in terms of wavelengths, generate identical second-harmonic fields in terms of shape. Results verify this for a medium with attenuation f1. For attenuation f1.1, deviations are found, and the high frequency subsequently performs worse than the low frequency. The results suggest that high frequencies are less able to suppress near-field echoes in the presence of a heterogeneous body wall than low frequencies.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Use of terms âPersian Lamb,â âBroadtail Lamb... Regulations § 301.8 Use of terms “Persian Lamb,” “Broadtail Lamb,” and “Persian-broadtail Lamb” permitted. (a) The term Persian Lamb may be used to describe the skin of the young lamb of the Karakul breed of sheep...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Lamb. 1280.111 Section 1280.111 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means...
Design of HIFU transducers for generating specified nonlinear ultrasound fields
Rosnitskiy, Pavel B.; Yuldashev, Petr V.; Sapozhnikov, Oleg A.; Maxwell, Adam; Kreider, Wayne; Bailey, Michael R.; Khokhlova, Vera A.
2016-01-01
Various clinical applications of high intensity focused ultrasound (HIFU) have different requirements for the pressure levels and degree of nonlinear waveform distortion at the focus. The goal of this work was to determine transducer design parameters that produce either a specified shock amplitude in the focal waveform or specified peak pressures while still maintaining quasilinear conditions at the focus. Multi-parametric nonlinear modeling based on the KZK equation with an equivalent source boundary condition was employed. Peak pressures, shock amplitudes at the focus, and corresponding source outputs were determined for different transducer geometries and levels of nonlinear distortion. Results are presented in terms of the parameters of an equivalent single-element, spherically shaped transducer. The accuracy of the method and its applicability to cases of strongly focused transducers were validated by comparing the KZK modeling data with measurements and nonlinear full-diffraction simulations for a single-element source and arrays with 7 and 256 elements. The results provide look-up data for evaluating nonlinear distortions at the focus of existing therapeutic systems as well as for guiding the design of new transducers that generate specified nonlinear fields. PMID:27775904
Mahjoubi, E; Amanlou, H; Hossein Yazdi, M; Aghaziarati, N; Noori, G R; Vahl, C I; Bradford, B J; Baumgard, L H
2016-06-01
Thirty-two Afshari lambs were used in a completely randomized design with a 2 × 2 factorial arrangement of treatments to evaluate a nutritional supplement designed to provide multiple gluconeogenic precursors during heat stress (HS). Lambs were housed in thermal neutral (TN) conditions and fed ad libitum for 8 d to obtain covariate data (period 1 [P1]) for the subsequent experimental period (period 2 [P2]). During P2, which lasted 9 d, half of the lambs were subjected to HS and the other 16 lambs were maintained in TN conditions but pair fed (PFTN) to the HS lambs. Half of the lambs in each thermal regime were fed (top-dressed) 100 g/d of a feed supplement designed to provide gluconeogenic precursors (8 lambs in HS [heat stress with Glukosa {HSG}] and 8 lambs in PFTN [pair-fed thermal neutral with Glukosa]) and the other lambs in both thermal regimes were fed only the basal control diet (HS without Glukosa [HSC] and pair-fed thermal neutral without Glukosa). Heat stress decreased DMI (14%) and by design there were no differences between the thermal treatments, but HSG lambs had increased DMI (7.5%; < 0.05) compared with the HSC lambs. Compared with PFTN lambs, rectal temperature and skin temperature at the rump, shoulder, and legs of HS lambs were increased ( < 0.05) at 0700 and 1400 h. Rectal temperature at 1400 h decreased for HSG lambs (0.15 ± 0.03°C; < 0.05) compared with HSC lambs. Despite similar DMI between thermal treatments, ADG for HS and PFTN lambs in P2 was decreased 55 and 85%, respectively, compared with lambs in P1 ( < 0.01). Although the prefeeding glucose concentration was not affected by thermal treatment or diet, HSG lambs had increased postfeeding glucose concentration compared with HSC lambs ( < 0.05). In contrast to the glucose responses, circulating insulin was influenced only by thermal treatment; HS lambs had increased insulin concentration ( < 0.01) before feeding and decreased concentration ( < 0.05) after feeding compared with PFTN lambs. Heat-stressed lambs had decreased NEFA concentration before feeding ( < 0.01) but not after feeding relative to PFTN lambs. Although this nutritional strategy did not affect ADG, the lower rectal temperature in HSG lambs indicates that dietary inclusion of a mixture of glucogenic precursors can potentially benefit animal health during HS.
NASA Astrophysics Data System (ADS)
Hu, Liang; Zhao, Nannan; Gao, Zhijian; Mao, Kai; Chen, Wenyu; Fu, Xin
2018-05-01
Determination of the distribution of a generated acoustic field is valuable for studying ultrasonic transducers, including providing the guidance for transducer design and the basis for analyzing their performance, etc. A method calculating the acoustic field based on laser-measured vibration velocities on the ultrasonic transducer surface is proposed in this paper. Without knowing the inner structure of the transducer, the acoustic field outside it can be calculated by solving the governing partial differential equation (PDE) of the field based on the specified boundary conditions (BCs). In our study, the BC on the transducer surface, i.e. the distribution of the vibration velocity on the surface, is accurately determined by laser scanning measurement of discrete points and follows a data fitting computation. In addition, to ensure the calculation accuracy for the whole field even in an inhomogeneous medium, a finite element method is used to solve the governing PDE based on the mixed BCs, including the discretely measured velocity data and other specified BCs. The method is firstly validated on numerical piezoelectric transducer models. The acoustic pressure distributions generated by a transducer operating in an homogeneous and inhomogeneous medium, respectively, are both calculated by the proposed method and compared with the results from other existing methods. Then, the method is further experimentally validated with two actual ultrasonic transducers used for flow measurement in our lab. The amplitude change of the output voltage signal from the receiver transducer due to changing the relative position of the two transducers is calculated by the proposed method and compared with the experimental data. This method can also provide the basis for complex multi-physical coupling computations where the effect of the acoustic field should be taken into account.
7 CFR 1280.112 - Lamb products.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Lamb products. 1280.112 Section 1280.112 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.112 Lamb products. Lamb...
Analysis of Rayleigh-Lamb Modes in Soft-solids with Application to Surface Wave Elastography
NASA Astrophysics Data System (ADS)
Benech, Nicolás; Grinspan, Gustavo; Aguiar, Sofía; Brum, Javier; Negreira, Carlos; tanter, Mickäel; Gennisson, Jean-Luc
The goal of Surface Wave Elastography (SE) techniques is to estimate the shear elasticity of the sample by measuring the surface wave speed. In SE the thickness of the sample is often assumed to be infinite, in this way, the surface wave speed is directly linked to the sample's shear elasticity. However for many applications this assumption is not true. In this work, we study experimentally the Rayleigh-Lamb modes in soft solids of finite thickness to explore the optimal conditions for SWE. Experiments were carried out in three tissue mimicking phantoms of different thicknesses (10 mm, 20 mm and 60 mm) and same shear elasticity. The surface waves were generated at the surface of the phantom using piston attached to a mechanical vibrator. The central frequency of the excitation was varied between 60 Hz to 160 Hz. One component of the displacement field generated by the piston was measured at the surface and in the bulk of the sample trough a standard speckle tracking technique using a 256 element, 7.5 MHz central frequency linear array and an ultrasound ultrafast electronics. Finally, by measuring the phase velocity at each excitation frequency, velocity dispersion curves were obtained for each phantom. The results show that instead of a Rayleigh wave, zero order symmetric (S0) and antisymmetric (A0) Lamb modes are excited with this type of source. Moreover, in this study we show that due to the near field effects of the source, which are appreciable only in soft solids at low frequencies, both Lamb modes are separable in time and space. We show that while the Ao mode dominates close the source, the S0 mode dominates far away.
NASA Astrophysics Data System (ADS)
Shan, Feng; Guo, Xiasheng; Tu, Juan; Cheng, Jianchun; Zhang, Dong
The high-intensity focused ultrasound (HIFU) has become an attractive therapeutic tool for the noninvasive tumor treatment. The ultrasonic transducer is the key component in HIFU treatment to generate the HIFU energy. The dimension of focal region generated by the transducer is closely relevant to the safety of HIFU treatment. Therefore, it is essential to numerically investigate the focal region of the transducer. Although the conventional acoustic wave equations have been used successfully to describe the acoustic field, there still exist some inherent drawbacks. In this work, we presented an axisymmetric isothermal multi-relaxation-time lattice Boltzmann method (MRT-LBM) model with the Bouzidi-Firdaouss-Lallemand (BFL) boundary condition in cylindrical coordinate system. With this model, some preliminary simulations were firstly conducted to determine a reasonable value of the relaxation parameter. Then, the validity of the model was examined by comparing the results obtained with the LBM results with the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and the Spheroidal beam equation (SBE) for the focused transducers with different aperture angles, respectively. In addition, the influences of the aperture angle on the focal region were investigated. The proposed model in this work will provide significant references for the parameter optimization of the focused transducer for applications in the HIFU treatment or other fields, and provide new insights into the conventional acoustic numerical simulations.
Multiharmonic Frequency-Chirped Transducers for Surface-Acoustic-Wave Optomechanics
NASA Astrophysics Data System (ADS)
Weiß, Matthias; Hörner, Andreas L.; Zallo, Eugenio; Atkinson, Paola; Rastelli, Armando; Schmidt, Oliver G.; Wixforth, Achim; Krenner, Hubert J.
2018-01-01
Wide-passband interdigital transducers are employed to establish a stable phase lock between a train of laser pulses emitted by a mode-locked laser and a surface acoustic wave generated electrically by the transducer. The transducer design is based on a multiharmonic split-finger architecture for the excitation of a fundamental surface acoustic wave and a discrete number of its overtones. Simply by introducing a variation of the transducer's periodicity p , a frequency chirp is added. This combination results in wide frequency bands for each harmonic. The transducer's conversion efficiency from the electrical to the acoustic domain is characterized optomechanically using single quantum dots acting as nanoscale pressure sensors. The ability to generate surface acoustic waves over a wide band of frequencies enables advanced acousto-optic spectroscopy using mode-locked lasers with fixed repetition rate. Stable phase locking between the electrically generated acoustic wave and the train of laser pulses is confirmed by performing stroboscopic spectroscopy on a single quantum dot at a frequency of 320 MHz. Finally, the dynamic spectral modulation of the quantum dot is directly monitored in the time domain combining stable phase-locked optical excitation and time-correlated single-photon counting. The demonstrated scheme will be particularly useful for the experimental implementation of surface-acoustic-wave-driven quantum gates of optically addressable qubits or collective quantum states or for multicomponent Fourier synthesis of tailored nanomechanical waveforms.
Alba-Hurtado, F; Romero-Escobedo, E; Muñoz-Guzmán, M A; Torres-Hernández, G; Becerril-Pérez, C M
2010-09-20
The study compares the parasitological and productive traits of Criollo lambs native to the central Mexican Plateau (CNCMP) and Suffolk (SU) lambs experimentally infected with Haemonchus contortus. CNCMP lambs (n=20) and SU lambs (n=15) were infected with L3 of H. contortus while five lambs of each genotype were kept as controls. Fecal egg count (FEC), packed cell volume (PCV), blood eosinophil number (BEN), ocular mucous membrane color (as measured by the FAMACHA index), changes in body condition score (BCS) and cumulative live weight gain (CLWG) were measured weekly during a 20-week period. On week 20, all animals were euthanized and the number of adult worms (AW) in the abomasum was counted. Infected SU lambs had higher (p<0.05) FEC and AW mean values compared to CNCMP lambs, which had a higher mean BEN count (p<0.05). Infected lambs had lower PCV values than controls, regardless of genotype, and had a negative correlation (r=-0.84, p<0.05) with the FAMACHA index. BCS tended to decline for infected SU lambs and increased slightly for infected CNCMP lambs. CLWG differed in all groups (p<0.05); infected SU lambs gained 12.1+/-1.9kg, infected CNCMP lambs gained 18.8+/-0.7kg, control SU lambs gained 34.6+/-1.6kg, and control CNCMP lambs gained 26.9+/-0.8kg. In conclusion, CNCMP lambs had a smaller worm burden, a better ability to maintain their productive traits, and were less affected by infection with Haemonchus contortus.
Frequency coded sensors incorporating tapers
NASA Technical Reports Server (NTRS)
Hines, Jacqueline H. (Inventor); Solie, Leland P. (Inventor)
2010-01-01
A surface acoustic wave device includes a piezoelectric substrate on which is formed a transducer that generates acoustic waves on the surface of the substrate from electrical waves received by the transducer. The waves are carried along an acoustic track to either a second transducer or a reflector. The transducers or transducer and reflector are formed of subsections that are constructed to operate at mutually different frequencies. The subsections of at least one of the transducers or transducer and reflector are out of alignment with respect to one another relative to the transverse of the propagation direction. The out of aligned subsections provide not only a frequency component but also a time to the signal output signal. Frequency response characteristics are improved. An alternative embodiment provides that the transducers and/or reflectors are continuously tapered instead of having discrete frequency subsections.
Jonker, A; Hickey, S M; Rowe, S J; Janssen, P H; Shackell, G; Elmes, S; Bain, W E; Wing, J; Greer, G J; Bryson, B; MacLean, S; Dodds, K G; Pinares-Patiño, C S; Young, E A; Knowler, K; Pickering, N K; McEwan, J C
2018-05-07
Methane (CH4) emission traits were previously found to be heritable and repeatable in sheep fed alfalfa pellets in respiration chambers (RC). More rapid screening methods are, however, required to increase genetic progress and to provide a cost effective method to the farming industry for maintaining the generation of breeding values in the future. The objective of the current study was to determine CH4 and carbon dioxide (CO2) emissions using several one-hour portable accumulation chamber (PAC) measurements from lambs and again as ewes, while grazing ryegrass based pasture. Many animals with PAC measurements were also measured in RC while fed alfalfa pellets at 2.0 × maintenance metabolizable energy requirements (MEm). Heritability estimates from mixed models for CH4 and CO2 production (g/d) were 0.19 and 0.16, respectively, when measured using PAC with lambs; 0.20 and 0.27, respectively, when measured using PAC with ewes; and 0.23 and 0.34, respectively, when measured using RC with lambs. For measured gas traits, repeatabilities of measurements collected 14 days apart ranged from 0.33 to 0.55 for PAC (combined lambs and ewes) and were greater at 0.65 to 0.76 for the same traits measured using RC. Genetic correlations (rg) between PAC in lambs and ewes were 0.99 for CH4, 0.93 for CH4+CO2 and 0.85 for CH4/(CH4+CO2), suggesting CH4 emissions in lambs and ewes are the same trait. Genetic correlations between PAC and RC measurements were lower, at 0.62 to 0.67 for CH4 and 0.41 to 0.42 for CH4+CO2, likely reflecting different environmental conditions associated with the protocols used with the two measurement methods. The CH4/(CH4+CO2) ratio was the most similar genetic trait measured using PAC (both lambs and ewes, 63 and 66% selection efficiency, respectively) compared with CH4 yield (g/kg DMI) measured using RC. These results suggest that PAC measurements have considerable value as a rapid low cost method to estimate breeding values for CH4 emissions in sheep.
Borton, R J; Loerch, S C; McClure, K E; Wulf, D M
2005-06-01
Targhee x Hampshire lambs (average BW 24 +/- 1 kg) were used to determine the effect of finishing on concentrate or by grazing ryegrass forage on slaughter weights of 52 kg (N) or 77 kg (H) on tissue accretion and lamb wholesale cutout. When fed to similar slaughter weights, the wholesale cuts of concentrate-fed lambs were heavier (P < 0.05) than the same cuts from forage-fed lambs; however, when expressed as a percentage of side weight, carcasses of forage-fed lambs had a higher (P < 0.001) percentage of leg than concentrate-fed lambs. Increasing slaughter weight from 52 to 77 kg resulted in a 1-kg increase in loin weight for lambs finished on concentrate and a 0.60-kg increase for lambs finished on forage (diet x slaughter weight, P < 0.03); however, the increased loin weight for lambs finished on concentrate was due largely to increased fat deposition. For lambs slaughtered at 77 kg, those finished on forage had more lean mass in the leg, loin, rack, and shoulder than those finished on concentrate, but lean mass in these cuts did not differ between diets for lambs slaughtered at 52 kg (diet x slaughter weight, P < 0.01). At the normal slaughter weight (52 kg), concentrate-fed lambs had 50% more dissectible fat than forage-fed lambs, whereas at the heavy slaughter weight, a 79% greater amount of dissectible fat was observed for concentrate- vs. forage-fed lambs (diet x slaughter weight, P < 0.001). Lean and fat accretion rates were higher (P < 0.001) for concentrate-fed lambs than for forage-fed lambs. The lean-to-fat ratio of forage-fed lambs was higher (P < 0.001) than that of concentrate-fed lambs; however, forage finishing decreased accretion rates of all tissues compared with concentrate feeding, and these differences between forage and concentrate feeding were magnified at heavier slaughter weights.
Manipulation of Liquids Using Phased Array Generation of Acoustic Radiation Pressure
NASA Technical Reports Server (NTRS)
Oeftering, Richard C. (Inventor)
2000-01-01
A phased array of piezoelectric transducers is used to control and manipulate contained as well as uncontained fluids in space and earth applications. The transducers in the phased array are individually activated while being commonly controlled to produce acoustic radiation pressure and acoustic streaming. The phased array is activated to produce a single pulse, a pulse burst or a continuous pulse to agitate, segregate or manipulate liquids and gases. The phased array generated acoustic radiation pressure is also useful in manipulating a drop, a bubble or other object immersed in a liquid. The transducers can be arranged in any number of layouts including linear single or multi- dimensional, space curved and annular arrays. The individual transducers in the array are activated by a controller, preferably driven by a computer.
Calibration of a horizontally acting force transducer with the use of a simple pendulum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taberner, Andrew J.; Hunter, Ian W.; BioInstrumentation Laboratory, Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139 and Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139
This article details the implementation of a method for calibrating horizontally measuring force transducers using a pendulum. The technique exploits the sinusoidal inertial force generated by a suspended mass as it pendulates about a point on the measurement axis of the force transducer. The method is used to calibrate a reconfigurable, custom-made force transducer based on exchangeable cantilevers with stiffness ranging from 10 to 10{sup 4} N/m. In this implementation, the relative combined standard uncertainty in the calibrated transducer stiffness is 0.41% while the repeatability of the calibration technique is 0.46%.
Management of maternal-offspring behavior to improve lamb survival in easy care sheep systems.
Everett-Hincks, J M; Dodds, K G
2008-04-01
This paper examines the environmental and management factors affecting lamb survival on high-performing sheep farms in New Zealand. Improved lambing percentage is the biggest contributor to higher profits on New Zealand sheep farms. Many sheep breeders have selected and bred ewes for increased fecundity over the last 4 decades. The increased proportion of ewes having triplets is of concern to farmers and to industry because neonatal lamb mortality is highest in triplets. The majority of lamb deaths occur in the first 3 d after birth and range from 5 to 30% for individual sheep flocks. The ability of a lamb to survive to weaning is determined by genetics, behavior, physiology, and the environment, including on-farm management practices. We investigated the effects of dam body condition in pregnancy, weather during lambing, lamb birth weight, and maternal behavior on single, twin, and triplet lamb viability at birth, lamb death risks from dystocia, and starvation exposure and survival through to weaning for 20 industry flocks from 2003 to 2004 (15,821 lambs). Ewes with higher body condition scores in mid pregnancy had heavier lambs at birth (P < 0.01). Lambs weighing 5.5 to 6 kg at birth (P < 0.01) were more likely to be viable at birth and survive to weaning than heavier or lighter lambs. Weather conditions during late pregnancy (P < 0.05) proved more important than conditions during lambing (P < 0.05) in determining lamb viability and survival through to weaning. Older ewes and ewes with triplets require considerably more attention for farmers to realize their production potential. This information can help formulate appropriate management programs to improve lamb survival rates under easy care farming systems.
Lamb-type waves generated by a cylindrical bubble oscillating between two planar elastic walls
Mekki-Berrada, F.; Thibault, P.; Marmottant, P.
2016-01-01
The volume oscillation of a cylindrical bubble in a microfluidic channel with planar elastic walls is studied. Analytical solutions are found for the bulk scattered wave propagating in the fluid gap and the surface waves of Lamb-type propagating at the fluid–solid interfaces. This type of surface wave has not yet been described theoretically. A dispersion equation for the Lamb-type waves is derived, which allows one to evaluate the wave speed for different values of the channel height h. It is shown that for h<λt, where λt is the wavelength of the transverse wave in the walls, the speed of the Lamb-type waves decreases with decreasing h, while for h on the order of or greater than λt, their speed tends to the Scholte wave speed. The solutions for the wave fields in the elastic walls and in the fluid are derived using the Hankel transforms. Numerical simulations are carried out to study the effect of the surface waves on the dynamics of a bubble confined between two elastic walls. It is shown that its resonance frequency can be up to 50% higher than the resonance frequency of a similar bubble confined between two rigid walls. PMID:27274695
Hot foil transducer skin friction sensor
NASA Technical Reports Server (NTRS)
Vranas, T. (Inventor)
1982-01-01
The device utilizes foil transducers with only one edge exposed to the fluid flow. The surfaces are polished producing a foil transducer that does not generate turbulence while sufficiently thick to carry the required electrical current for high temperature fluid flow. The assembly utilizes a precut layered metal sandwich with attached electrodes eliminating a need for welding and individual sensor calibration.
Assessment of commercial lamb meat quality by British and Spanish taste panels.
Sañudo, C; Nute, G R; Campo, M M; María, G; Baker, A; Sierra, I; Enser, M E; Wood, J D
1998-01-01
Trained sensory panels in Britain and Spain assessed loin meat from commercial lambs purchased in Spain, which included Welsh lamb (imported from Britain) and two Spanish breeds (Merino and Rasa Aragonesa). The British panel also assessed British lamb purchased in local butcher shops and supermarkets. Sensory panels, in each country, received meat from the same lambs and used their local methods of cooking and assessment. Spanish panels used unstructured line scales to measure lamb odour intensity, tenderness, juiciness, lamb flavour intensity and two hedonic scales of flavour liking and overall liking. The British panel used 8 point category scales with the same attributes. Results from both panels in objective parameters were in agreement, hence showing that different trained sensory panels may arrive at the same conclusion. However, when panellists were allowed to make hedonic judgements (preference), the British panel preferred British lamb and the Spanish panel preferred Spanish lamb. This finding has important consequences for lamb producers who export their lambs and demonstrates that the underlying reasons for different preferences should be investigated. Production variables are discussed in relation to their influence on lamb eating quality and as a way to tailor lamb eating quality attributes familiar to consumers in the importing country.
Lin, Kuang-Wei; Hall, Timothy L; Xu, Zhen; Cain, Charles A
2015-08-01
When histotripsy pulses shorter than 2 cycles are applied, the formation of a dense bubble cloud relies only on the applied peak negative pressure (p-) exceeding the "intrinsic threshold" of the medium (absolute value of 26-30 MPa in most soft tissues). It has been found that a sub-threshold high-frequency probe pulse (3 MHz) can be enabled by a sub-threshold low-frequency pump pulse (500 kHz) where the sum exceeds the intrinsic threshold, thus generating lesion-producing dense bubble clouds ("dual-beam histotripsy"). Here, the feasibility of using an imaging transducer to provide the high-frequency probe pulse in the dual-beam histotripsy approach is investigated. More specifically, an ATL L7-4 imaging transducer (Philips Healthcare, Andover, MA, USA), pulsed by a V-1 Data Acquisition System (Verasonics, Redmond, WA, USA), was used to generate the high-frequency probe pulses. The low-frequency pump pulses were generated by a 20-element 345-kHz array transducer, driven by a custom high-voltage pulser. These dual-beam histotripsy pulses were applied to red blood cell tissue-mimicking phantoms at a pulse repetition frequency of 1 Hz, and optical imaging was used to visualize bubble clouds and lesions generated in the red blood cell phantoms. The results indicated that dense bubble clouds (and resulting lesions) were generated when the p- of the sub-threshold pump and probe pulses combined constructively to exceed the intrinsic threshold. The average size of the smallest reproducible lesions using the imaging probe pulse enabled by the sub-threshold pump pulse was 0.7 × 1.7 mm, whereas that using the supra-threshold pump pulse alone was 1.4 × 3.7 mm. When the imaging transducer was steered laterally, bubble clouds and lesions were steered correspondingly until the combined p- no longer exceeded the intrinsic threshold. These results were also validated with ex vivo porcine liver experiments. Using an imaging transducer for dual-beam histotripsy can have two advantages: (i) lesion steering can be achieved using the steering of the imaging transducer (implemented with the beamformer of the accompanying programmable ultrasound system), and (ii) treatment can be simultaneously monitored when the imaging transducer is used in conjunction with an ultrasound imaging system. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Lin, Kuang-Wei; Hall, Timothy L.; Xu, Zhen; Cain, Charles A.
2015-01-01
When applying histotripsy pulses shorter than 2 cycles, the formation of a dense bubble cloud only relies on the applied peak negative pressure (p-) exceeding the “intrinsic threshold” of the medium (absolute value of 26 – 30 MPa in most soft tissue). A previous study conducted by our research group showed that a sub-threshold high-frequency probe pulse (3 MHz) can be enabled by a sub-threshold low-frequency pump pulse (500 kHz) where the sum exceeds the intrinsic threshold, thus generating lesion-producing dense bubble clouds (“dual-beam histotripsy”). This paper investigates the feasibility of using an imaging transducer to provide the high-frequency probe pulse in the dual-beam histotripsy approach. More specifically, an ATL L7–4 imaging transducer, pulsed by a Verasonics V-1 Data Acquisition System, was used to generate the high-frequency probe pulses. The low-frequency pump pulses were generated by a 20-element 345 kHz array transducer, driven by a custom high voltage pulser. These dual-beam histotripsy pulses were applied to red-blood-cell (RBC) tissue-mimicking phantoms at a pulse repetition frequency of 1 Hz, and optical imaging was used to visualize bubble clouds and lesions generated in the RBC phantoms. The results showed that dense bubble clouds (and resulting lesions) were generated when the p- of the sub-threshold pump and probe pulses combined constructively to exceed the intrinsic threshold. The average size of the smallest reproducible lesions using the imaging probe pulse enabled by the sub-threshold pump pulse was 0.7 × 1.7 mm while that using the supra-threshold pump pulse alone was 1.4 × 3.7 mm. When the imaging transducer was steered laterally, bubble clouds and lesions were steered correspondingly until the combined p- no longer exceeded the intrinsic threshold. These results were also validated with ex vivo porcine liver experiments. Using an imaging transducer for dual-beam histotripsy can have two advantages, 1) lesion steering can be achieved using the steering of the imaging transducer (implemented with the beamformer of the accompanying programmable ultrasound system) and 2) treatment can be simultaneously monitored when the imaging transducer is used in conjunction with an ultrasound imaging system. PMID:25929995
Freitas-de-Melo, A; Ungerfeld, R; Hötzel, M J; Orihuela, A; Pérez-Clariget, R
2017-02-01
Low pasture allowance during gestation affects ewes' BW at parturition, the bond with their lamb, lamb development, and thus also may affect their responses to weaning. The objectives were to determine if native pasture allowance from before conception until late pregnancy affects ewe-lamb behaviours at lambing, ewes' milk yield, lambs' BW, and the behavioural and physiological changes of ewes and lambs at weaning. From 23 days before conception until 122 days of pregnancy, 24 ewes grazed on two different native pasture allowances: high (10 to 12 kg of dry matter (DM)/100 kg of BW per day; HPA treatment; n=12) or low (5 to 8 kg of DM/100 kg of BW per day; LPA treatment; n=12). Thereafter, all ewes grazed on Festuca arundinacea and received rice bran and crude glycerine. Ewes' body condition score (BCS) and BW were recorded during pregnancy and postpartum periods. Milk yield was determined on days 32, 41 and 54 after lambing. Lambs' BW was recorded from birth until 72 days after lambing. Latency from parturition until the ewe licked her lamb, maternal behaviour score (a test that evaluates maternal attachment to the lamb) and latency for lamb to stand up and suckle were determined. The behaviour of the lambs and ewes was recorded before and after weaning (at 65 days). The ewes' serum total protein, albumin and globulin concentrations were measured before and after weaning. The HPA ewes presented greater BW (P<0.005) and BCS (P<0.005) than the LPA ewes during pregnancy and postpartum (P<0.04), and had a greater milk yield than the LPA ewes (P<0.03). Treatments did not influence any behaviour at lambing, lambs' BW, neither the ewes' behavioural and physiological changes at weaning. HPA lambs paced and vocalized more than LPA lambs (P<0.0001). The variation of albumin concentration before and after weaning was greater in the HPA lambs than in the LPA lambs (P<0.0001). In conclusion, although ewes' BW, BCS and milk production were affected by pasture allowance until late pregnancy, this did not affect the behaviours that lead to the establishment of the mother-young bond, nor the ewes' behavioural responses at weaning. Lambs reared by ewes that grazed on low pasture allowance during pregnancy presented fewer behavioural changes and a lower decrease of albumin concentration after weaning. Lambs' BW was not affected by the feeding received by their mothers.
A flex-compressive-mode piezoelectric transducer for mechanical vibration/strain energy harvesting.
Li, Xiaotian; Guo, Mingsen; Dong, Shuxiang
2011-04-01
A piezoelectric transducer for harvesting energy from ambient mechanical vibrations/strains under pressure condition was developed. The proposed transducer was made of two ring-type piezoelectric stacks, one pair of bow-shaped elastic plates, and one shaft that pre-compresses them. This transducer works in flex-compressive (F-C) mode, which is different from a conventional flex-tensional (F-T) one, to transfer a transversely applied force F into an amplified longitudinal force N pressing against the two piezo-stacks via the two bowshaped elastic plates, generating a large electric voltage output via piezoelectric effect. Our experimental results show that without an electric load, an F-C mode piezo-transducer could generate a maximum electric voltage output of up to 110 Vpp, and with an electric load of 40 κΩ, it a maximum power output of 14.6 mW under an acceleration excitation of 1 g peak-peak at the resonance frequency of 87 Hz. © 2011 IEEE
Ekiz, Bulent; Kocak, Omur; Yalcintan, Hulya; Yilmaz, Alper
2016-02-01
Effects of suckling length (45, 75 and 120 days) and birth type (single and twin) on lamb growth, slaughtering and carcass quality characteristics were investigated using 40 Kivircik lambs. SC-45 and SC-75 lambs were weaned at 45 and 75 days of age, respectively, whilst SC-120 lambs remained with their mothers until the end of the experimental period. Lambs from all studied groups were slaughtered at 120 days of age. Weaning treatment caused a decrease in average daily gain in SC-45 and SC-75 lambs, and therefore, final weight was higher in SC-120 lambs than lambs from weaned groups. SC-120 lambs had higher empty body weight, cold carcass weight, dressing percentage, carcass measurements, carcass fatness (proportions of the kidney knob and channel fat, subcutaneous and intramuscular fat in pelvic limb) and non-carcass fatness (omental and mesenteric fat proportion) than weaned lambs. As a conclusion, the potential losses in meat production due to weaning should be considered before deciding the weaning of lambs at early ages.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means ovine animals of any age, including ewes and rams. ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means ovine animals of any age, including ewes and rams. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means ovine animals of any age, including ewes and rams. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.111 Lamb. Lamb means ovine animals of any age, including ewes and rams. ...
A U-shaped linear ultrasonic motor using longitudinal vibration transducers with double feet.
Liu, Yingxiang; Liu, Junkao; Chen, Weishan; Shi, Shengjun
2012-05-01
A U-shaped linear ultrasonic motor using longitudinal vibration transducers with double feet was proposed in this paper. The proposed motor contains a horizontal transducer and two vertical transducers. The horizontal transducer includes two exponential shape horns located at the leading ends, and each vertical transducer contains one exponential shape horn. The horns of the horizontal transducer and the vertical transducer intersect at the tip ends where the driving feet are located. Longitudinal vibrations are superimposed in the motor and generate elliptical motions at the driving feet. The two vibration modes of the motor are discussed, and the motion trajectories of driving feet are deduced. By adjusting the structural parameters, the resonance frequencies of two vibration modes were degenerated. A prototype motor was fabricated and measured. Typical output of the prototype is no-load speed of 854 mm/s and maximum thrust force of 40 N at a voltage of 200 V(rms).
Carcass and meat quality of Assaf milk fed lambs: Effect of rearing system and sex.
Rodríguez, A B; Landa, R; Bodas, R; Prieto, N; Mantecón, A R; Giráldez, F J
2008-10-01
The effect of sex and rearing system on growth and carcass and meat characteristics of milk fed Assaf lambs was studied. Thirty-six lambs, 18 males and 18 females were used. Twelve lambs remained with their mothers throughout the experiment (NR). Within 24-36h of birth, the rest were housed individually and fed twice a day ad libitum (AAR) or at 70% of ad libitum consumption (RAR) with reconstituted cow's milk. Sex did not affect animal performance, yet females showed higher carcass and non-carcass fat deposits. NR lambs showed greater BWG than AAR fed lambs, and AAR, higher than the RAR. Differences between naturally and artificially reared lambs in CCW and killing out percentage were not significant. Empty digestive tract and mesenteric fat weights were greater for RAR than NR lambs, with the AAR lambs demonstrating intermediate values; conversely, omental fat was greater in NR lambs. Carcass ether extract content was greater for NR lambs, possibly due to the greater growth. Use of ad libitum cow's milk substitute in suckling lambs twice a day resulted in less body weight gain but similar killing out percentages compared to naturally raised lambs. A 70% restricted supply increased the days in suckling and reduced carcass fatness and compactness. Except for water loss, which was less in NR than artificially fed lambs, no differences were found in meat characteristics.
A KLM-circuit model of a multi-layer transducer for acoustic bladder volume measurements.
Merks, E J W; Borsboom, J M G; Bom, N; van der Steen, A F W; de Jong, N
2006-12-22
In a preceding study a new technique to non-invasively measure the bladder volume on the basis of non-linear wave propagation was validated. It was shown that the harmonic level generated at the posterior bladder wall increases for larger bladder volumes. A dedicated transducer is needed to further verify and implement this approach. This transducer must be capable of both transmission of high-pressure waves at fundamental frequency and reception of up to the third harmonic. For this purpose, a multi-layer transducer was constructed using a single element PZT transducer for transmission and a PVDF top-layer for reception. To determine feasibility of the multi-layer concept for bladder volume measurements, and to ensure optimal performance, an equivalent mathematical model on the basis of KLM-circuit modeling was generated. This model was obtained in two subsequent steps. Firstly, the PZT transducer was modeled without PVDF-layer attached by means of matching the model with the measured electrical input impedance. It was validated using pulse-echo measurements. Secondly, the model was extended with the PVDF-layer. The total model was validated by considering the PVDF-layer as a hydrophone on the PZT transducer surface and comparing the measured and simulated PVDF responses on a wave transmitted by the PZT transducer. The obtained results indicated that a valid model for the multi-layer transducer was constructed. The model showed feasibility of the multi-layer concept for bladder volume measurements. It also allowed for further optimization with respect to electrical matching and transmit waveform. Additionally, the model demonstrated the effect of mechanical loading of the PVDF-layer on the PZT transducer.
Electromagnetomechanical elastodynamic model for Lamb wave damage quantification in composites
NASA Astrophysics Data System (ADS)
Borkowski, Luke; Chattopadhyay, Aditi
2014-03-01
Physics-based wave propagation computational models play a key role in structural health monitoring (SHM) and the development of improved damage quantification methodologies. Guided waves (GWs), such as Lamb waves, provide the capability to monitor large plate-like aerospace structures with limited actuators and sensors and are sensitive to small scale damage; however due to the complex nature of GWs, accurate and efficient computation tools are necessary to investigate the mechanisms responsible for dispersion, coupling, and interaction with damage. In this paper, the local interaction simulation approach (LISA) coupled with the sharp interface model (SIM) solution methodology is used to solve the fully coupled electro-magneto-mechanical elastodynamic equations for the piezoelectric and piezomagnetic actuation and sensing of GWs in fiber reinforced composite material systems. The final framework provides the full three-dimensional displacement as well as electrical and magnetic potential fields for arbitrary plate and transducer geometries and excitation waveform and frequency. The model is validated experimentally and proven computationally efficient for a laminated composite plate. Studies are performed with surface bonded piezoelectric and embedded piezomagnetic sensors to gain insight into the physics of experimental techniques used for SHM. The symmetric collocation of piezoelectric actuators is modeled to demonstrate mode suppression in laminated composites for the purpose of damage detection. The effect of delamination and damage (i.e., matrix cracking) on the GW propagation is demonstrated and quantified. The developed model provides a valuable tool for the improvement of SHM techniques due to its proven accuracy and computational efficiency.
A NEW PRINCIPLE FOR ELECTROMAGNETIC CATHETER FLOW METERS*
Kolin, Alexander
1969-01-01
An electromagnetic catheter flow meter is described in which the magnetic field is generated by two parallel bundles of wire carrying equal currents in opposite directions. The electrodes are fixed centrally to the insulated wire bundles that generate the magnetic field. The flow sensor is flexible, resembling a split catheter. The flow transducer is designed to constrict as it is introduced through a branch artery and to expand in the main artery over the span of its diameter. The principle is suitable for branch flow measurement as well as for measurement of flow in a major artery or vein by the same transducer. A special method of guiding the electrode wires results in a zero base line at zero flow for the entire range of diameters accommodating the field generating coil. The electrodes could be used in this configuration with a magnetic field generated by coils external to the patient for blood flow measurements with a catheter of reduced gauge. The transducer can be made smaller in circumference than those employed in other electromagnetic flow measuring catheter devices. This feature is of special value for envisaged clinical uses (percutaneous introduction) to minimize surgical intervention. The velocity sensitivity of the flow transducer is a logarithmic function of the tube diameter. The flow throughout the entire tube cross section contributes to the flow signal. It is sufficient to calibrate the transducer by one measurement in a dielectric conduit of less than maximum diameter. The sensitivity at other diameters follows from a logarithmic plot. The diameter of the blood vessel is outlined by the transducer in radiograms, thus obviating the need for radiopaque materials. The principle was demonstrated by measurements in vitro. Experiments in vivo, derivation of equations, and construction details will be published elsewhere. Images PMID:5257127
Biasing of Capacitive Micromachined Ultrasonic Transducers.
Caliano, Giosue; Matrone, Giulia; Savoia, Alessandro Stuart
2017-02-01
Capacitive micromachined ultrasonic transducers (CMUTs) represent an effective alternative to piezoelectric transducers for medical ultrasound imaging applications. They are microelectromechanical devices fabricated using silicon micromachining techniques, developed in the last two decades in many laboratories. The interest for this novel transducer technology relies on its full compatibility with standard integrated circuit technology that makes it possible to integrate on the same chip the transducers and the electronics, thus enabling the realization of extremely low-cost and high-performance devices, including both 1-D or 2-D arrays. Being capacitive transducers, CMUTs require a high bias voltage to be properly operated in pulse-echo imaging applications. The typical bias supply residual ripple of high-quality high-voltage (HV) generators is in the millivolt range, which is comparable with the amplitude of the received echo signals, and it is particularly difficult to minimize. The aim of this paper is to analyze the classical CMUT biasing circuits, highlighting the features of each one, and to propose two novel HV generator architectures optimized for CMUT biasing applications. The first circuit proposed is an ultralow-residual ripple (<5 [Formula: see text]) HV generator that uses an extremely stable sinusoidal power oscillator topology. The second circuit employs a commercially available integrated step-up converter characterized by a particularly efficient switching topology. The circuit is used to bias the CMUT by charging a buffer capacitor synchronously with the pulsing sequence, thus reducing the impact of the switching noise on the received echo signals. The small area of the circuit (about 1.5 cm 2 ) makes it possible to generate the bias voltage inside the probe, very close to the CMUT, making the proposed solution attractive for portable applications. Measurements and experiments are shown to demonstrate the effectiveness of the new approaches presented.
Rastle-Simpson, S; D'Souza, K; Redhead, A; Singh-Knights, D; Baptiste, Q; Knights, M
2017-10-01
The effect of season (S), lamb rearing system (RT) and grain supplementation (GS) on post-partum fertility in Katahdin ewes and growth in Katahdin lambs was evaluated. Katahdin ewes were bred to lamb in fall (n = 36) or spring (n = 56) and at approximately 2.5 months post-partum were randomly assigned to be permanently separated or to continue to suckle their lambs for an additional 3 months. All ewes were joined with rams following treatment to synchronize oestrus. Weaned (W, n = 84) and continuously suckled lambs (CSK, n = 88) were fed forage only (n = 84; hay and pasture for fall- and spring-born lambs respectively) or were supplemented (n = 88; 18% crude protein ration ad libitum) and all weighed biweekly. Ewes rebred in the fall had a shorter ram introduction to lambing interval (p < 0.05), higher prolificacy (p = 0.001) and higher lambing rates (p = 0.02); however, the proportion of ewes lambing was not affected by season. The first service lambing rate was lower in ewes continuously suckling lambs in the spring, but not in the fall breeding season (S × RT, p = 0.03). Lambs that continuously suckled their dams and were supplemented grew quicker and gained more (p < 0.001) than their weaned and unsupplemented counterparts. The effect of CSK on growth rate of lambs was greater in the spring (RT × S; p = 0.05), and the effect of supplementation on growth rate of lambs was greater in the fall (GS × S; p < 0.0001). In conclusion, Katahdin lambs achieved higher weight gains from continuous suckling and grain supplementation. Moreover, Katahdin ewes are capable of early rebreeding post-partum while suckling their lambs, which makes them suited for use in accelerated lambing programmes. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.
Observations on the alimentary tract of gnotobiotic lambs.
Lysons, R J; Alexander, T J; Wellstead, P D; Jennings, I W
1976-01-01
Seventeen gnotobiotic lambs were reared up to 21 weeks of age on cows' milk followed by sterile solid diets similar to diets fed to conventional lambs. Seven were inoculated with limited defined populations of rumen bacteria, seven were left uninoculated and three were dosed with rumen contents from conventional sheep ('conventionalised'). Seven naturally-born lambs were reared for purposes of comparison. As with other species of gnotobiotic animals, both the inoculated and the uninoculated gnotobiotic lambs had small, poorly developed lymph nodes, soft colon contents and thin intestinal walls. Unlike other species the caeca of gnotobiotic lambs were of normal size. The overall size of the reticulo-rumen including contents relative to body weight was similar in gnotobiotic and conventional lambs. However, macroscopically, the musculature of the rumen seemed to be poorly developed and histological studies showed hypoplasia of the muscle tissue of both the rumen and reticulum. Rumination was noted only infrequently in gnotobiotic lambs. The epithelium of the rumen and reticulum of the uninoculated gnotobiotic lambs was similar to that of neonatal lambs, but there was normal development of papillae in gnotobiotic lambs inoculated with limited defined populations of rumen bacteria and in conventionalised lambs. Degenerative changes were observed histologically in some of the organs of gnotobiotic lambs which were consistent with nutritional deficiencies.
Chillara, Vamshi Krishna; Pantea, Cristian; Sinha, Dipen N.
2017-02-06
We present a very simple approach to generate a collimated ultrasonic beam that exploits the natural Bessel-like vibration pattern of the radial modes of a piezoelectric disc with lateral clamping. This eliminates the need for the conventional annular Bessel pattern of the electrodes with individual electrode excitation on the piezo-disc, thus simplifying the transducer design. Numerical and experimental studies are carried out to investigate the Bessel-like vibration patterns of these radial modes showing an excellent agreement between these two studies. Measured ultrasonic beam- pro les in water from the radial modes con rm the profile to be a Bessel beam.more » Collimated beam generation from radial modes is investigated using a coupled electromechanical finite-element model. It is found that clamping the lateral edges of piezoelectric transducers results in a high-degree of collimation with practically no side-lobes similar to a parametric array beam. Ultrasonic beam- profile measurements in water with both free and clamped piezoelectric transducer are presented. The collimated beam generation using the present technique of using the laterally clamped radial modes finds significant applications in low-frequency imaging through highly attenuating materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chillara, Vamshi Krishna; Pantea, Cristian; Sinha, Dipen N.
We present a very simple approach to generate a collimated ultrasonic beam that exploits the natural Bessel-like vibration pattern of the radial modes of a piezoelectric disc with lateral clamping. This eliminates the need for the conventional annular Bessel pattern of the electrodes with individual electrode excitation on the piezo-disc, thus simplifying the transducer design. Numerical and experimental studies are carried out to investigate the Bessel-like vibration patterns of these radial modes showing an excellent agreement between these two studies. Measured ultrasonic beam- pro les in water from the radial modes con rm the profile to be a Bessel beam.more » Collimated beam generation from radial modes is investigated using a coupled electromechanical finite-element model. It is found that clamping the lateral edges of piezoelectric transducers results in a high-degree of collimation with practically no side-lobes similar to a parametric array beam. Ultrasonic beam- profile measurements in water with both free and clamped piezoelectric transducer are presented. The collimated beam generation using the present technique of using the laterally clamped radial modes finds significant applications in low-frequency imaging through highly attenuating materials.« less
Tian, Jiajun; Zhang, Qi; Han, Ming
2013-03-11
Active ultrasonic testing is widely used for medical diagnosis, material characterization and structural health monitoring. Ultrasonic transducer is a key component in active ultrasonic testing. Due to their many advantages such as small size, light weight, and immunity to electromagnetic interference, fiber-optic ultrasonic transducers are particularly attractive for permanent, embedded applications in active ultrasonic testing for structural health monitoring. However, current fiber-optic transducers only allow effective ultrasound generation at a single location of the fiber end. Here we demonstrate a fiber-optic device that can effectively generate ultrasound at multiple, selected locations along a fiber in a controllable manner based on a smart light tapping scheme that only taps out the light of a particular wavelength for laser-ultrasound generation and allow light of longer wavelengths pass by without loss. Such a scheme may also find applications in remote fiber-optic device tuning and quasi-distributed biochemical fiber-optic sensing.
Design of HIFU Transducers for Generating Specified Nonlinear Ultrasound Fields.
Rosnitskiy, Pavel B; Yuldashev, Petr V; Sapozhnikov, Oleg A; Maxwell, Adam D; Kreider, Wayne; Bailey, Michael R; Khokhlova, Vera A
2017-02-01
Various clinical applications of high-intensity focused ultrasound have different requirements for the pressure levels and degree of nonlinear waveform distortion at the focus. The goal of this paper is to determine transducer design parameters that produce either a specified shock amplitude in the focal waveform or specified peak pressures while still maintaining quasi-linear conditions at the focus. Multiparametric nonlinear modeling based on the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation with an equivalent source boundary condition was employed. Peak pressures, shock amplitudes at the focus, and corresponding source outputs were determined for different transducer geometries and levels of nonlinear distortion. The results are presented in terms of the parameters of an equivalent single-element spherically shaped transducer. The accuracy of the method and its applicability to cases of strongly focused transducers were validated by comparing the KZK modeling data with measurements and nonlinear full diffraction simulations for a single-element source and arrays with 7 and 256 elements. The results provide look-up data for evaluating nonlinear distortions at the focus of existing therapeutic systems as well as for guiding the design of new transducers that generate specified nonlinear fields.
Zhang, Shuzeng; Li, Xiongbing; Jeong, Hyunjo
2017-01-01
A theoretical model, along with experimental verification, is developed to describe the generation, propagation and reception of a Rayleigh wave using angle beam wedge transducers. The Rayleigh wave generation process using an angle beam wedge transducer is analyzed, and the actual Rayleigh wave sound source distributions are evaluated numerically. Based on the reciprocity theorem and considering the actual sound source, the Rayleigh wave beams are modeled using an area integral method. The leaky Rayleigh wave theory is introduced to investigate the reception of the Rayleigh wave using the angle beam wedge transducers, and the effects of the wave spreading in the wedge and transducer size are considered in the reception process. The effects of attenuations of the Rayleigh wave and leaky Rayleigh wave are discussed, and the received wave results with different sizes of receivers are compared. The experiments are conducted using two angle beam wedge transducers to measure the Rayleigh wave, and the measurement results are compared with the predictions using different theoretical models. It is shown that the proposed model which considers the wave spreading in both the sample and wedges can be used to interpret the measurements reasonably. PMID:28632183
Zhang, Shuzeng; Li, Xiongbing; Jeong, Hyunjo
2017-06-20
A theoretical model, along with experimental verification, is developed to describe the generation, propagation and reception of a Rayleigh wave using angle beam wedge transducers. The Rayleigh wave generation process using an angle beam wedge transducer is analyzed, and the actual Rayleigh wave sound source distributions are evaluated numerically. Based on the reciprocity theorem and considering the actual sound source, the Rayleigh wave beams are modeled using an area integral method. The leaky Rayleigh wave theory is introduced to investigate the reception of the Rayleigh wave using the angle beam wedge transducers, and the effects of the wave spreading in the wedge and transducer size are considered in the reception process. The effects of attenuations of the Rayleigh wave and leaky Rayleigh wave are discussed, and the received wave results with different sizes of receivers are compared. The experiments are conducted using two angle beam wedge transducers to measure the Rayleigh wave, and the measurement results are compared with the predictions using different theoretical models. It is shown that the proposed model which considers the wave spreading in both the sample and wedges can be used to interpret the measurements reasonably.
NASA Astrophysics Data System (ADS)
Su, Hua; Lu, Ronghua; Chang, Judy C.; Kan, Yuet Wai
1997-12-01
About 70% of hepatocellular carcinomas are known to express α -fetoprotein, which is normally expressed in fetal but not in adult livers. To induce herpes simplex virus-thymidine kinase expression in these cancer cells, we constructed an adeno-associated viral vector containing the HSV-TK gene under the control of the α -fetoprotein enhancer and albumin promoter. We previously demonstrated in vitro that although this vector can transduce a variety of human cells, only transduced AFP and albumin-expressing hepatocellular carcinoma cell lines were sensitive to killing by ganciclovir (GCV). In the present study, we explored the effect of this vector on hepatocellular carcinoma cells in vivo. Subcutaneous tumors generated in nude mice by implanting hepatocellular carcinoma cells previously transduced with this vector shrank dramatically after treatment with GCV. Bystander effect was also observed on the tumors generated by mixing transduced and untransduced cells. To test whether the tumor cells can be transduced by the virus in vivo, we injected the recombinant adeno-associated virus into tumors generated by untransduced hepatocarcinoma cell line. Tumor growth were retarded after treatment with GCV. These experiments demonstrate the feasibility of in vivo transduction of tumor cell with rAAV.
7 CFR 1280.206 - Certification of organizations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion... substantial quantity of lamb or lamb products; and (2) A primary purpose of the organization is in the...
Croft, A; Duffield, T; Menzies, P; Leslie, K; Bagg, R; Dick, P
2000-01-01
The effect of tilmicosin on the incidence of clinical mastitis and subsequent lamb performance was studied in 9 sheep flocks in Ontario. Ewes were treated randomly with either tilmicosin or placebo approximately one month prior to lambing. Outcome was assessed by comparing rates of clinical mastitis, palpable udder abnormalities, and preweaning (50-day) lamb weights between the 2 treatment groups, while controlling for other important variables. Lambs raised by multiparous ewes treated with tilmicosin were significantly heavier than lambs from placebo-treated multiparous ewes at 50 days. Lambs from tilmicosin-treated ewes were on average 0.52 kg heavier than lambs in the placebo group. There was no difference between treatment groups in the weight of lambs from first parity ewes. Tilmicosin treatment resulted in a 43% decrease in palpable udder abnormalities. Incidence of clinical mastitis did not differ between experimental groups. The administration of tilmicosin prelambing, at the time of routine clostridial disease vaccination, may be a beneficial and convenient way to reduce mastitis infection and improve the preweaning gain of lambs. PMID:10769768
Factors affecting fecal egg counts in periparturient Katahdin ewes and their lambs.
Notter, D R; Burke, J M; Miller, J E; Morgan, J L M
2017-01-01
Selection for low fecal egg counts (FEC) can be used to genetically enhance resistance to gastrointestinal nematode parasites in growing lambs, thereby reducing the frequency of use of anthelmintics, facilitating marketing of organic lamb, and reducing the risk of development of anthelmintic resistance by the parasite. Recording of FEC in lambs has, therefore, been incorporated into several national sheep genetic evaluation programs. Ewes in late gestation and early lactation are also vulnerable to parasite infection and commonly experience a periparturient rise in FEC. This study was designed to assess factors associated with the periparturient rise in FEC in Katahdin ewes and associated changes in FEC in their lambs. Data came from 1,487 lambings by 931 Katahdin ewes from 11 farms in the Eastern United States. Fecal egg counts were measured in ewes at approximately 0, 30, and 60 d postpartum and in their lambs at approximately 60, 90, and 120 d of age. Approximately 1,400 lambs were evaluated at each measurement age. Data were analyzed separately for ewes and lambs and also initially analyzed separately for each measurement time. Repeated-measures analyses were then used to evaluate responses across measurement times. In ewes, FEC peaked at approximately 28 d postpartum, and we concluded that informative periparturient FEC could be obtained from 1 wk before until approximately 5 wk after lambing. Yearling ewes had higher FEC than adult ewes ( < 0.01), and ewes that nursed twin or triplet lambs had higher FEC than ewes that nursed single lambs ( < 0.01). In lambs, FEC increased through approximately 120 d of age. Lambs from yearling ewes and lambs nursed in larger litters were, like their dams, at greater risk of parasitism ( < 0.05). Ewes and lambs in these groups would benefit from enhanced monitoring of parasite loads at lambing and in early lactation. Correlations () between FEC in lambs at 90 d of age and FEC in ewes at 0, 30, and 60 d postpartum of 0.05 to 0.09 ( ≤ 0.05) support the presence of a genetic relationship between these 2 indicators of parasite resistance.
NASA Astrophysics Data System (ADS)
Allison, Eric
In this investigation, a propulsion system is introduced for propelling and guiding an object through a fluid. Thrust for forward motion and for turning is produced by acoustic waves generated by piezoelectric ultrasonic transducers. The principle of operation of the transducers is described, and methods are presented for the design of the entire system, including the transducers, signal generator, guidance and control system, and the power source. A wirelessly controlled proof-of-concept device was constructed. This device demonstrates the operation and practicality of the propulsion and guidance systems and illustrates that they may be employed in situations where the use of conventional propulsive devices such as propellers or jets is unfeasible.
Lévy, F; Keller, M; Cornilleau, F; Moussu, C; Ferreira, G
2010-09-01
Ewes form a selective olfactory memory for their lambs after 2 hr of mother-young interaction following parturition. Mothers will subsequently reject any strange lamb at suckling. The present study investigated whether artificial vaginocervical stimulation (VCS) allows the formation of a selective bond with an unfamiliar lamb and whether it interferes with the maintenance of the bond formed with the familiar lamb. At 2 hr postpartum, mothers were separated from their familiar lamb after having formed a selective bond with it and were given 10 min of mechanical VCS. In the "VCS + lamb" group (n = 24) an unfamiliar lamb was left with the ewe for 2 hr whereas in the "VCS no lamb" group (n = 26) the mother was left alone for the same period of time. Ewes of the "no VCS" group (n = 14) did not receive any VCS. In the majority of animals of the "VCS + lamb" group (23/24) VCS induced a complete acceptance of the unfamiliar lamb without any disruption of the bond previously formed with the familiar lamb. VCS or 2 hr of separation did not disrupt the maintenance of the selective bond initially formed with the familiar lamb since all the ewes of the "VCS no lamb" and "no VCS" groups accepted it at suckling.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Lamb. 65.190 Section 65.190 Agriculture Regulations of..., PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS, PEANUTS, AND GINSENG General Provisions Definitions § 65.190 Lamb. Lamb means meat produced from sheep. ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND... producer, feeder, or seedstock producer shares the proceeds received for the lamb or lamb products sold..., or livestock market in the business of receiving lambs or lamb products for sale on commission for or...
7 CFR 1280.217 - Lamb purchases.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Lamb purchases. 1280.217 Section 1280.217 Agriculture... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Assessments § 1280.217 Lamb purchases. (a...
Acharya, M; Burke, J M; Coffey, K P; Kegley, E B; Miller, J E; Smyth, E; Welborn, M G; Terrill, T H; Mosjidis, J A; Rosenkrans, C
2016-04-01
Prolonged feeding of sericea lespedeza (SL) previously led to reduced serum concentrations of Mo, a cofactor in an enzyme complex that may be involved in weight gain. The current objective was to determine the effect of Mo supplementation on changes in serum, fecal, urine, and liver concentrations of trace minerals in lambs fed SL leaf meal pellets. Thirty ram lambs weaned in May (84 ± 1.5 d of age and 27 ± 1.1 kg; D 0) were blocked by BW, breed type (full or three-fourths Katahdin), and EBV of parasite resistance and randomly assigned to be fed 900 g/d of an alfalfa-based supplement (CON; = 10) or a SL-based supplement ( = 20) for 103 d. Supplements were formulated to be isonitrogenous and isocaloric and to meet trace mineral requirements. Within the SL group, individual lambs were administered either 5 mL water or 5 mL of water with 163.3 mg of sodium molybdate (SLMO). Serum was collected on d 28, 56, and 104; a liver sample was collected by biopsy on d 104 to determine concentrations of trace minerals. Data were analyzed using a mixed model and orthogonal contrasts. Serum concentrations of Mo increased in response to the drench and were greatest in SLMO lambs and then CON lambs and lowest in SL lambs ( < 0.001). Concentrations of Mo in the liver ( < 0.001) were similar between CON and SLMO lambs and were lower in SL lambs than other groups. Serum ( < 0.001) and liver ( = 0.013) concentrations of zinc (Zn) were reduced in both SL and SLMO lambs compared with CON lambs. Serum concentrations of cobalt (Co) increased in CON lambs compared with SL and SLMO lambs between d 0 and 56 but were similar on d 104 (diet × day, < 0.005) as with concentrations in the liver. Serum and liver concentrations of copper (Cu) were greatest ( < 0.001 and < 0.001, respectively) in CON lambs followed by SL lambs and then SLMO lambs. Serum concentrations of selenium (Se) tended ( = 0.10) to be reduced in SL lambs compared with CON and SLMO lambs, but concentrations in the liver were reduced in SL lambs compared with CON lambs and even more so in SLMO lambs ( < 0.003). Although the dietary Mo did increase stores of Mo in the animal and reduced copper, trace minerals associated with metalloproteins-Mo, copper, selenium, and zinc-were reduced in the liver of SL- and/or SLMO-fed lambs. These reductions could be associated with the lower weight gains previously observed after prolonged feeding of SL.
Establishment and development of ruminal hydrogenotrophs in methanogen-free lambs.
Fonty, Gérard; Joblin, Keith; Chavarot, Michel; Roux, Remy; Naylor, Graham; Michallon, Fabien
2007-10-01
The aim of this work was to determine whether reductive acetogenesis can provide an alternative to methanogenesis in the rumen. Gnotobiotic lambs were inoculated with a functional rumen microbiota lacking methanogens and reared to maturity on a fibrous diet. Lambs with a methanogen-free rumen grew well, and the feed intake and ruminal volatile fatty acid concentrations for lambs lacking ruminal methanogens were lower but not markedly dissimilar from those for conventional lambs reared on the same diet. A high population density (10(7) to 10(8) cells g(-1)) of ruminal acetogens slowly developed in methanogen-free lambs. Sulfate- and fumarate-reducing bacteria were present, but their population densities were highly variable. In methanogen-free lambs, the hydrogen capture from fermentation was low (28 to 46%) in comparison with that in lambs containing ruminal methanogens (>90%). Reductive acetogenesis was not a significant part of ruminal fermentation in conventional lambs but contributed 21 to 25% to the fermentation in methanogen-free meroxenic animals. Ruminal H(2) utilization was lower in lambs lacking ruminal methanogens, but when a methanogen-free lamb was inoculated with a methanogen, the ruminal H(2) utilization was similar to that in conventional lambs. H(2) utilization in lambs containing a normal ruminal microflora was age dependent and increased with the animal age. The animal age effect was less marked in lambs lacking ruminal methanogens. Addition of fumarate to rumen contents from methanogen-free lambs increased H(2) utilization. These findings provide the first evidence from animal studies that reductive acetogens can sustain a functional rumen and replace methanogens as a sink for H(2) in the rumen.
Structural health monitoring of plates with surface features using guided ultrasonic waves
NASA Astrophysics Data System (ADS)
Fromme, P.
2009-03-01
Distributed array systems for guided ultrasonic waves offer an efficient way for the long-term monitoring of the structural integrity of large plate-like structures. The measurement concept involving baseline subtraction has been demonstrated under laboratory conditions. For the application to real technical structures it needs to be shown that the methodology works equally well in the presence of structural and surface features. Problems employing this structural health monitoring concept can occur due to the presence of additional changes in the signal reflected at undamaged parts of the structure. The influence of the signal processing parameters and transducer placement on the damage detection and localization accuracy is discussed. The use of permanently attached, distributed sensors for the A0 Lamb wave mode has been investigated. Results are presented using experimental data obtained from laboratory measurements and Finite Element simulated signals for a large steel plate with a welded stiffener.
Notter, D R; Mousel, M R; Lewis, G S; Leymaster, K A; Taylor, J B
2017-09-01
Ewe productivity (i.e., total number or weight of lambs weaned per breeding ewe) is a key indicator of lamb production efficiency. This study compared various measures of ewe productivity and ewe and lamb performance among ewes of 3 breed types mated to rams of 4 terminal-sire breed types in an extensive rangeland production system. Purebred Rambouillet ( = 212), purebred Polypay ( = 236), and crossbred Romanov-White Dorper × Rambouillet (RW-RA; = 231) ewes were produced from locally adapted Polypay and Rambouillet ewes and then annually mated to Columbia, Suffolk, Columbia × Suffolk, or Suffolk × Columbia sires for up to 4 yr, beginning at 1 yr of age. The cumulative number and weight of lambs weaned through 4 yr were greater for RW-RA (5.9 lambs and 153 kg, respectively) and Polypay ewes (4.9 lambs and 123 kg, respectively) than for Rambouillet ewes (2.9 lambs and 99 kg, respectively) and also were greater for RW-RA ewes than for Polypay ewes (all < 0.001). Greater productivity of RW-RA and Polypay ewes, compared with Rambouillet ewes, was driven by greater lambing rates (ewes lambing per ewe exposed) as ewe lambs (87 and 77 vs. 31%, respectively; < 0.001) and greater ( < 0.001) litter sizes as ewe lambs (1.3, 1.3, and 1.0, respectively) and adult ewes (2.1, 2.0, and 1.6, respectively). The RW-RA ewes also had greater longevity ( < 0.01) and cumulative lambing rates ( < 0.001) than Polypay and Rambouillet ewes. Lamb BW at birth and weaning in adult ewes favored less-prolific Rambouillet ewes ( < 0.001), but after adjustment for type of birth and rearing and weaning age, differences in weaning BW among ewe breed types were small and not significant ( = 0.08). Effects of sire breed type on measures of cumulative ewe productivity were not significant ( > 0.74), but Suffolk-sired lambs had the heaviest adjusted birth weights ( = 0.01) and Columbia-sired lambs tended to have the lightest adjusted weaning weights ( = 0.12). Combined effects of heterosis and additive breed effects were associated with greater lambing rates in ewe lambs, larger litters at all ages, and substantially greater number and weight of lambs weaned for Polypay and RW-RA ewes than for Rambouillet ewes.
Physics of direct-contact ultrasonic cloth drying process
Peng, Chang; Ravi, Saitej; Patel, Viral K.; ...
2017-02-27
Existing methods of drying fabrics involve energy-intensive thermal evaporation of moisture from clothes. Drying fabrics using high-frequency vibrations of piezoelectric transducers can substantially reduce drying time and energy consumption. In this method, vibrational energy generates instability on the liquid-air interface and mechanically ejects water from a wet fabric. For the first time, the physics of the ultrasonic fabric drying process in direct-contact mode is studied. The kinematic and thermal responses of water droplets and fabrics on piezoelectric crystal transducers and metal mesh–based transducers are studied. The results suggest that on piezoelectric crystal transducers, the response of a droplet subjected tomore » ultrasonic excitation is dictated by the relative magnitude of the surface tension and the ultrasonic excitation forces. The drying process for a fabric on the studied transducers consists of two regimes—vibrational and thermal. When the water content is high, the vibrational forces can eject bulk water rapidly. But the more strongly bound water within the smaller fabric pores evaporates by the thermal energy generated as a result of the viscous losses. Our study finds that a metal mesh–based transducer is more suitable for dewatering fabrics, as it facilitates the ejection of water from the fabric–transducer interface to the opposite side of the mesh. A demonstration unit developed consumes 10–20% of the water latent heat energy at water contents greater than 20%.« less
Energetic balance in an ultrasonic reactor using focused or flat high frequency transducers.
Hallez, L; Touyeras, F; Hihn, J Y; Klima, J
2007-09-01
In order to undertake irradiation of polymer blocks or films by ultrasound, this paper deals with the measurements of ultrasonic power and its distribution within the cell by several methods. The electric power measured at the transducer input is compared to the ultrasonic power input to the cell evaluated by calorimetry and radiation force measurement for different generator settings. Results obtained in the specific case of new transducer types (composites and focused composites i.e., HIFU: high intensity focused ultrasound) provide an opportunity to conduct a discussion about measurement methods. It has thus been confirmed that these measurement techniques can be applied to HIFU transducers. For all cases, results underlined the fact that measurement of radiation pressure for power evaluation is more adapted to low powers (<15 W) and that measurement by calorimetry is a valid technique for global energy measurements. Composites and monocomponent transducers were compared and it appears that the presence of an adaptation glass plate reduces the efficiency of the monocomponent transducers. The distribution of ultrasonic intensity is qualitatively depicted by sono-chemiluminescence of luminol. Finally, the quantity of energy absorbed by samples placed in the sound field is determined and the temperature distribution monitored as a function of wall distance. This energetic balance allows us to understand the global behaviour of all experimental set-ups made up of a generator-transducer-liquid and sample.
Physics of direct-contact ultrasonic cloth drying process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Chang; Ravi, Saitej; Patel, Viral K.
Existing methods of drying fabrics involve energy-intensive thermal evaporation of moisture from clothes. Drying fabrics using high-frequency vibrations of piezoelectric transducers can substantially reduce drying time and energy consumption. In this method, vibrational energy generates instability on the liquid-air interface and mechanically ejects water from a wet fabric. For the first time, the physics of the ultrasonic fabric drying process in direct-contact mode is studied. The kinematic and thermal responses of water droplets and fabrics on piezoelectric crystal transducers and metal mesh–based transducers are studied. The results suggest that on piezoelectric crystal transducers, the response of a droplet subjected tomore » ultrasonic excitation is dictated by the relative magnitude of the surface tension and the ultrasonic excitation forces. The drying process for a fabric on the studied transducers consists of two regimes—vibrational and thermal. When the water content is high, the vibrational forces can eject bulk water rapidly. But the more strongly bound water within the smaller fabric pores evaporates by the thermal energy generated as a result of the viscous losses. Our study finds that a metal mesh–based transducer is more suitable for dewatering fabrics, as it facilitates the ejection of water from the fabric–transducer interface to the opposite side of the mesh. A demonstration unit developed consumes 10–20% of the water latent heat energy at water contents greater than 20%.« less
An Ultrasonic Clamp for Bloodless Partial Nephrectomy
NASA Astrophysics Data System (ADS)
Lafon, Cyril; Bouchoux, Guillaume; Murat, François Joseph; Birer, Alain; Theillère, Yves; Chapelon, Jean Yves; Cathignol, Dominique
2007-05-01
Maximum conservation of the kidney is preferable through partial nephrectomy for patients at risk of disease recurrence of renal cancers. Haemostatic tools are needed in order to achieve bloodless surgery and reduce post surgery morbidity. Two piezo-ceramic transducers operating at a frequency of 4 MHz were mounted on each arm of a clamp. When used for coagulation purposes, two transducers situated on opposite arms of the clamp were driven simultaneously. Heat delivery was optimized as each transducers mirrored back to targeted tissues the wave generated by the opposite transducer. Real-time treatment monitoring with an echo-based technique was also envisaged with this clamp. Therapy was periodically interrupted so one transducer could generate a pulse. The echo returning from the opposite transducer was treated. Coagulation necroses were obtained in vitro on substantial thicknesses (23-38mm) of pig liver over exposure durations ranging from 30s to 130s, and with acoustic intensities of less than 15W/cm2 per transducer. Both kidneys of two pigs were treated in vivo with the clamp (14.5W/cm2 for 90s), and the partial nephrectomies performed proved to be bloodless. In vitro and in vivo, wide transfixing lesions corresponded to an echo energy decrease superior to -10dB and parabolic form of the time of flight versus treatment time. In conclusion, this ultrasound clamp has proven to be an excellent mean for achieving monitored haemostasis in kidney.
Soysal, Deniz; Cibik, Recep; Aydin, Cenk; Ak, İbrahim
2011-04-01
Growth performance, carcass characteristics, post-slaughtering and haematological parameters of Kivircik and Karacabey Merino male lambs in conventional and organic management systems were compared. The animals which were weaned at 7 weeks of age were divided into Kivircik conventional, Kivircik organic (KO), Karacabey Merino conventional and Karacabey Merino organic (MO) groups containing 12 lambs each. Fattening was ended when lambs attained 35 kg of live weight. The time to attain the determined fattening weight was significantly different among the groups, and Merino lambs having higher live weight gain were earlier than Kivircik lambs (p < 0.05). Overall conventional (CG) and organic group lambs were also compared. Live weight gain, intra-abdominal fat amount, external fat thickness and visceral organ weight were significantly higher in CG lambs (p < 0.05). Higher haematocrit and erythrocyte counts were obtained with the CG group (p < 0.05), whilst triglyceride, total plasma cholesterol and lipoprotein (HDL, LDL, VLDL) levels between groups were not significant. Pneumonia was the unique infection, with an incidence of 50% (six lambs) and 16.6% (two lambs) for MO and KO animals, respectively. The mortality rate was 16.6% (two lambs) for MO group, whilst no mortality was recorded for KO group animals. The present study has shown that although Karacabey merino lambs had higher growth performance compared to Kivircik lambs, organically fattened lambs in whole exhibited inferior growth performance. Lower infection and mortality observed with Kivircik lambs suggested that they could be more resistant to infections and outdoor environmental conditions.
Guided wave crack detection and size estimation in stiffened structures
NASA Astrophysics Data System (ADS)
Bhuiyan, Md Yeasin; Faisal Haider, Mohammad; Poddar, Banibrata; Giurgiutiu, Victor
2018-03-01
Structural health monitoring (SHM) and nondestructive evaluation (NDE) deals with the nondestructive inspection of defects, corrosion, leaks in engineering structures by using ultrasonic guided waves. In the past, simplistic structures were often considered for analyzing the guided wave interaction with the defects. In this study, we focused on more realistic and relatively complicated structure for detecting any defect by using a non-contact sensing approach. A plate with a stiffener was considered for analyzing the guided wave interactions. Piezoelectric wafer active transducers were used to produce excitation in the structures. The excitation generated the multimodal guided waves (aka Lamb waves) that propagate in the plate with stiffener. The presence of stiffener in the plate generated scattered waves. The direct wave and the additional scattered waves from the stiffener were experimentally recorded and studied. These waves were considered as a pristine case in this research. A fine horizontal semi-circular crack was manufactured by using electric discharge machining in the same stiffener. The presence of crack in the stiffener produces additional scattered waves as well as trapped waves. These scattered waves and trapped wave modes from the cracked stiffener were experimentally measured by using a scanning laser Doppler vibrometer (SLDV). These waves were analyzed and compared with that from the pristine case. The analyses suggested that both size and shape of the horizontal crack may be predicted from the pattern of the scattered waves. Different features (reflection, transmission, and mode-conversion) of the scattered wave signals are analyzed. We found direct transmission feature for incident A0 wave mode and modeconversion feature for incident S0 mode are most suitable for detecting the crack in the stiffener. The reflection feature may give a better idea of sizing the crack.
Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves
NASA Astrophysics Data System (ADS)
Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei
2018-05-01
Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRADE REPRESENTATIVE IMPLEMENTATION OF TARIFF-RATE QUOTA FOR IMPORTS OF LAMB MEAT § 2014.2 Definitions... meanings assigned as follows: (a) Lamb meat means fresh, chilled, or frozen lamb meat, provided for in...-quota lamb meat means lamb meat that is entered under the in-quota rate of duty. (c) Participating...
7 CFR 59.302 - Mandatory weekly reporting for lambs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory weekly reporting for lambs. 59.302 Section... (CONTINUED) LIVESTOCK MANDATORY REPORTING Lamb Reporting § 59.302 Mandatory weekly reporting for lambs. (a... domestic from imported market purchases: (1) The quantity of lambs purchased through a negotiated purchase...
USDA-ARS?s Scientific Manuscript database
Genetic parameters for ewe reproductive traits [number of lambs born (NLB) and number of lambs weaned (NLW)] and ewe peri-parturient rise (PPR) fecal egg counts (FEC) at lambing (PPR0) and at 30-d post lambing (PPR30), and their genetic relationships with lamb BW and FEC in Katahdin sheep were estim...
Stuen, S; Bergström, K
2001-01-01
The effect of 2 different oxytetracycline treatments in acute E. phagocytophila infected lambs was investigated. Twenty 5-month-old lambs of the Dala and Rygja breeds were used. Ten lambs were inoculated intravenously with a stabilate of an ovine E. phagocytophila strain. On the third day of fever, 4 lambs were given long-acting oxytetracycline (Terramycin prolongatum vet®, Pfizer) (20 mg/kg) intramuscularly and another 4 lambs were given short-acting oxytetracycline (Terramycin vet®, Pfizer) (10 mg/kg) intravenously for 5 consecutive days. The lambs were examined for the presence of Ehrlichia infection by blood smear evaluation, polymerase chain reaction (PCR) and antibody titre against E. equi. One month after the last antibiotic treatment, 250 ml citrate blood from each of these lambs were inoculated into each of 10 susceptible lambs, which were observed during the following 6 weeks. The results indicate that oxytetracycline given in the acute stage of the infection may effectively teminate the development of fever, rickettsemia and weight reduction in E. phagocytophila infected lambs. No difference was observed between the 2 treatment groups. However, at least 3 of 8 antibiotic treated lambs (37.5%) were still infected with granulocytic Ehrlichia 3 months after treatment. PMID:11887394
Acoustooptic pulse-echo transducer system
NASA Technical Reports Server (NTRS)
Claus, R. O.; Wade, J. C.
1983-01-01
A pulse-echo transducer system which uses an ultrasonic generating element and an optical detection technique is described. The transmitting transducer consists of a concentric ring electrode pattern deposited on a circular, X-cut quartz substrate with a circular hole in the center. The rings are independently pulsed with a sequence high voltage signals phased in such a way that the ultrasonic waves generated by the separate rings superimpose to produce a composite field which is focused at a controllable distance below the surface of the specimen. The amplitude of the field reflected from this focus position is determined by the local reflection coefficient of the medium at the effective focal point. By processing the signals received for a range of ultrasonic transducer array focal lengths, the system can be used to locate and size anomalies within solids and liquids. Applications in both nondestructive evaluation and biomedical scanning are suggested.
A novel serrated columnar phased array ultrasonic transducer
NASA Astrophysics Data System (ADS)
Zou, Cheng; Sun, Zhenguo; Cai, Dong; Song, Hongwei; Chen, Qiang
2016-02-01
Traditionally, wedges are required to generate transverse waves in a solid specimen and mechanical rotation device is needed for interrogation of a specimen with a hollow bore, such as high speed railway locomotive axles, turbine rotors, etc. In order to eliminate the mechanical rotation process, a novel array pattern of phased array ultrasonic transducers named as serrated columnar phased array ultrasonic transducer (SCPAUT) is designed. The elementary transducers are planar rectangular, located on the outside surface of a cylinder. This layout is aimed to generate electrically rotating transverse waveforms so as to inspect the longitudinal cracks on the outside surface of a specimen which has a hollow bore at the center, such as the high speed railway locomotive axles. The general geometry of the SCPAUT and the inspection system are illustrated. A FEM model and mockup experiment has been carried out. The experiment results are in good agreement with the FEM simulation results.
A novel ultrasonic clutch using near-field acoustic levitation.
Chang, Kuo-Tsi
2004-10-01
This paper investigates design, fabrication and drive of an ultrasonic clutch with two transducers. For the two transducers, one serving as a driving element of the clutch is connected to a driving shaft via a coupling, and the other serving as a slave element of the clutch is connected to a slave shaft via another coupling. The principle of ultrasonic levitation is first expressed. Then, a series-resonant inverter is used to generate AC voltages at input terminals of each transducer, and a speed measuring system with optic sensors is used to find the relationship between rotational speed of the slave shaft and applied voltage of each transducer. Moreover, contact surfaces of the two transducers are coupled by the frictional force when both the two transducers are not energized, and separated using the ultrasonic levitation when at least one of the two transducers is energized at high voltages at resonance.
Derscheid, Rachel J; van Geelen, Albert; Berkebile, Abigail R; Gallup, Jack M; Hostetter, Shannon J; Banfi, Botond; McCray, Paul B; Ackermann, Mark R
2014-02-01
Recent studies have revealed that the human and nonrodent mammalian airway mucosa contains an oxidative host defense system. This three-component system consists of the hydrogen peroxide (H2O2)-producing enzymes dual oxidase (Duox)1 and Duox2, thiocyanate (SCN(-)), and secreted lactoperoxidase (LPO). The LPO-catalyzed reaction between H2O2 and SCN(-) yields the bactericidal hypothiocyanite (OSCN(-)) in airway surface liquid (ASL). Although SCN(-) is the physiological substrate of LPO, the Duox/LPO/halide system can generate hypoiodous acid when the iodide (I(-)) concentration is elevated in ASL. Because hypoiodous acid, but not OSCN(-), inactivates respiratory syncytial virus (RSV) in cell culture, we used a lamb model of RSV to test whether potassium iodide (KI) could enhance this system in vivo. Newborn lambs received KI by intragastric gavage or were left untreated before intratracheal inoculation of RSV. KI treatment led to a 10-fold increase in ASL I(-) concentration, and this I(-) concentration was approximately 30-fold higher than that measured in the serum. Also, expiratory effort, gross lung lesions, and pulmonary expression of an RSV antigen and IL-8 were reduced in the KI-treated lambs as compared with nontreated control lambs. Inhibition of LPO activity significantly increased lesions, RSV mRNA, and antigen. Similar experiments in 3-week-old lambs demonstrated that KI administration was associated with reduced gross lesions, decreased RSV titers in bronchoalveolar lavage fluid, and reduced RSV antigen expression. Overall, these data indicate that high-dose KI supplementation can be used in vivo to lessen the severity of RSV infections, potentially through the augmentation of mucosal oxidative defenses.
Suh, Jung Hee; Jarad, George; VanDeVoorde, Rene G.; Miner, Jeffrey H.
2011-01-01
Pierson syndrome is a congenital nephrotic syndrome with ocular and neurological defects caused by mutations in LAMB2, the gene encoding the basement membrane protein laminin β2 (Lamβ2). It is the kidney glomerular basement membrane (GBM) that is defective in Pierson syndrome, as Lamβ2 is a component of laminin-521 (LM-521; α5β2γ1), the major laminin in the mature GBM. In both Pierson syndrome and the Lamb2−/− mouse model for this disease, laminin β1 (Lamβ1), a structurally similar homolog of Lamβ2, is marginally increased in the GBM, but it fails to fully compensate for the loss of Lamβ2, leading to the filtration barrier defects and nephrotic syndrome. Here we generated several lines of Lamβ1 transgenic mice and used them to show that podocyte-specific Lamβ1 expression in Lamb2−/− mice abrogates the development of nephrotic syndrome, correlating with a greatly extended lifespan. In addition, the more Lamβ1 was expressed, the less urinary albumin was excreted. Transgenic Lamβ1 expression increased the level of Lamα5 in the GBM of rescued mice, consistent with the desired increased deposition of laminin-511 (α5β1γ1) trimers. Ultrastructural analysis revealed occasional knob-like subepithelial GBM thickening but intact podocyte foot processes in aged rescued mice. These results suggest the possibility that up-regulation of LAMB1 in podocytes, should it become achievable, would likely lessen the severity of nephrotic syndrome in patients carrying LAMB2 mutations. PMID:21876163
Suh, Jung Hee; Jarad, George; VanDeVoorde, Rene G; Miner, Jeffrey H
2011-09-13
Pierson syndrome is a congenital nephrotic syndrome with ocular and neurological defects caused by mutations in LAMB2, the gene encoding the basement membrane protein laminin β2 (Lamβ2). It is the kidney glomerular basement membrane (GBM) that is defective in Pierson syndrome, as Lamβ2 is a component of laminin-521 (LM-521; α5β2γ1), the major laminin in the mature GBM. In both Pierson syndrome and the Lamb2(-/-) mouse model for this disease, laminin β1 (Lamβ1), a structurally similar homolog of Lamβ2, is marginally increased in the GBM, but it fails to fully compensate for the loss of Lamβ2, leading to the filtration barrier defects and nephrotic syndrome. Here we generated several lines of Lamβ1 transgenic mice and used them to show that podocyte-specific Lamβ1 expression in Lamb2(-/-) mice abrogates the development of nephrotic syndrome, correlating with a greatly extended lifespan. In addition, the more Lamβ1 was expressed, the less urinary albumin was excreted. Transgenic Lamβ1 expression increased the level of Lamα5 in the GBM of rescued mice, consistent with the desired increased deposition of laminin-511 (α5β1γ1) trimers. Ultrastructural analysis revealed occasional knob-like subepithelial GBM thickening but intact podocyte foot processes in aged rescued mice. These results suggest the possibility that up-regulation of LAMB1 in podocytes, should it become achievable, would likely lessen the severity of nephrotic syndrome in patients carrying LAMB2 mutations.
Mixing of ultrasonic Lamb waves in thin plates with quadratic nonlinearity.
Li, Feilong; Zhao, Youxuan; Cao, Peng; Hu, Ning
2018-07-01
This paper investigates the propagation of Lamb waves in thin plates with quadratic nonlinearity by one-way mixing method using numerical simulations. It is shown that an A 0 -mode wave can be generated by a pair of S 0 and A 0 mode waves only when mixing condition is satisfied, and mixing wave signals are capable of locating the damage zone. Additionally, it is manifested that the acoustic nonlinear parameter increases linearly with quadratic nonlinearity but monotonously with the size of mixing zone. Furthermore, because of frequency deviation, the waveform of the mixing wave changes significantly from a regular diamond shape to toneburst trains. Copyright © 2018 Elsevier B.V. All rights reserved.
Modal simulation analysis of novel 3D elliptical ultrasonic transducer
NASA Astrophysics Data System (ADS)
Kurniawan, R.; Ali, S.; Ko, T. J.
2018-03-01
This paper aims to present the modal simulation analysis results of a novel 3D elliptical ultrasonic transducer. This research aims to develop a novel elliptical transducer that works in ultrasonic and is able to generate a three dimensional motion in Cartesian space. The concept of the transducer design is basically to find a coupling frequency of the longitudinal-bending-bending mode. To achieve that purpose, the modal simulation analysis was performed to find a proper dimension of the transducer, thus the natural frequency of the 1st longitudinal mode is much closed with the two of natural frequency of the 3rd bending mode. The finite element modelling (FEM) was used to perform this work.
Apparatus for checking the direction of polarization of shear-wave ultrasonic transducers
Karplus, Henry H. B.
1980-01-01
An apparatus for checking the direction of polarization of shear-wave ultrasonic transducers comprises a first planar surface for mounting the shear-wave transducer, a second planar surface inclined at a predetermined angle to the first surface to generate longitudinal waves by mode conversion, and a third planar surface disposed at a second predetermined angle to the first for mounting a longitudinal-wave ultrasonic transducer. In an alternate embodiment, two second planar surfaces at the predetermined angle are placed at an angle to each other. The magnitude of the shear wave is a function of the angle between the direction of polarization of the transducer and the mode-conversion surface.
Apparatus for checking the direction of polarization of shear-wave ultrasonic transducers
Karplus, H.H.B.; Forster, G.A.
An apparatus for checking the direction of polarization of shear-wave ultrasonic transducers comprises a first planar surface for mounting the shear-wave transducer, a second planar surface inclined at a predetermined angle to the first surface to generate longitudinal waves by mode conversion, and a third planar surface disposed at a second predetermined angle to the first for mounting a longitudinal-wave ultransonic transducer. In an alternate embodiment, two second planar surfaces at the predetermined angle are placed at an angle to each other. The magnitude of the shear wave is a function of the angle between the direction of polarization of the transducer and the mode-conversion surface.
The numerical simulation of Lamb wave propagation in laser welding of stainless steel
NASA Astrophysics Data System (ADS)
Zhang, Bo; Liu, Fang; Liu, Chang; Li, Jingming; Zhang, Baojun; Zhou, Qingxiang; Han, Xiaohui; Zhao, Yang
2017-12-01
In order to explore the Lamb wave propagation in laser welding of stainless steel, the numerical simulation is used to show the feature of Lamb wave. In this paper, according to Lamb dispersion equation, excites the Lamb wave on the edge of thin stainless steel plate, and presents the reflection coefficient for quantizing the Lamb wave energy, the results show that the reflection coefficient is increased with the welding width increasing,
The effects of feeding clinoptilolite on hematology, performance, and health of newborn lambs.
Norouzian, M A; Valizadeh, R; Khadem, A A; Afzalzadeh, A; Nabipour, A
2010-11-01
The effects of feeding clinoptilolite on hematology, performance, and health of newborn Balouchi lambs were evaluated in this experiment. In a completely randomized design, 30 newborn lambs were allocated to three groups and fed by basal diet (C0; without clinoptilolite) and C1 and C2 (the basal diet plus 1.5% and 3% clinoptilolite, respectively, for 6 weeks (3 weeks before and 3 weeks after weaning)). Blood samples were taken from all lambs, at the time when the animals were allocated to the experimental diet and at the end of each week of experiment, and analyzed for hematology, plasma fibrinogen, and total protein. Performance and health of all lambs were measured. Fecal consistency score and diarrhea severity were evaluated. There was no difference between lambs in case of hematological parameters. Lambs fecal consistency score and severity of diarrhea were lowest (P < 0.05) for lambs on C1 and C2 and highest for lambs on C0. Dry matter intake and feed conservation ratio were similar between the groups of lambs fed by different diets, but daily gain of lambs differed significantly (P < 0.05) and was higher in C2. It was concluded that addition of 3% clinoptilolite to starter diet of newborn lamb can reduce incidence and severity of diarrhea, although its effect on hematology and performance was negligible.
7 CFR 59.301 - Mandatory Daily Reporting for Lambs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory Daily Reporting for Lambs. 59.301 Section 59... (CONTINUED) LIVESTOCK MANDATORY REPORTING Lamb Reporting § 59.301 Mandatory Daily Reporting for Lambs. (a) In... prices for lambs (per hundredweight) established on that day as F.O.B. feedlot or delivered at the plant...
The duration of passive protection against Taenia ovis larvae in lambs.
Heath, D D; Yong, W K; Osborn, P J; Parmeter, S N; Lawrence, S B; Twaalfhoven, H
1979-10-01
In an attempt to induce passive protection in lambs against Taenia ovis larvae that would last for the 15-20 weeks from birth to slaughter as fat lambs, one group of ewes was immunized by a series of injections of 2000, 4000, 8000, 16 000 and 32 000 activated oncospheres of Taenia ovis prior to parturition. Another group of ewes was not immunized. All ewes had previously grazed pasture lightly infected with T. ovis eggs. Most lambs from non-immunized ewes developed cysts after oral infection with T. ovis eggs. However, no lambs from immunized ewes developed cysts up to and including 6 weeks after birth. Between 8 and 16 weeks after birth a proportion of lambs were found to be susceptible to infection. By 18 weeks after birth all lambs were apparently susceptible. The 99% confidence band for the mean duration of demonstrable complement-fixing antibody titres was 6.2-7.8 weeks for lambs from immunized ewes. The persistence of maternal protective antibody in some lambs could possibly preclude successful active immunization of all lambs against T. ovis larvae before 18 weeks of age.
Mousel, M R; Notter, D R; Leeds, T D; Zerby, H N; Moeller, S J; Lewis, G S
2013-05-01
Postfabrication carcass component weights of 517 crossbred wether lambs were analyzed to evaluate 4 terminal-sire breeds. Wethers were produced over 3 yr from single-sire matings of 22 Columbia, 22 USMARC-Composite (Composite), 21 Suffolk, and 17 Texel rams to adult Rambouillet ewes. Lambs were reared to weaning in an extensive western rangeland production system and finished in a feedlot on a high-energy finishing diet. When wethers reached a mean BW of 54.4, 61.2, or 68.0 kg, they were transported to The Ohio State University abattoir for harvest. After refrigeration for approximately 24 h, chilled carcass weight (CCW) was measured, carcasses were fabricated according to Style A of Institutional Meat Purchase Specifications, and postfabrication weights were recorded. At comparable numbers of days on feed, Suffolk-sired lambs had heavier (P < 0.04) neck, breast, shoulder, foreshank, rack, loin, leg, sirloin, roast-ready rack, trimmed loin, and boneless leg cuts than progeny of the other sire breeds. Boneless sirloins were heavier (P < 0.01) for Suffolk-sired than Composite-sired lambs but did not differ from those for Columbia- or Texel-sired lambs. Columbia- and Suffolk-sired lambs had heavier (P < 0.01) hindshanks than Texel-sired lambs. Suffolk-sired lambs had heavier (P < 0.01) high-value cuts (rack, loin, leg, and sirloin) and trimmed high-value cuts than progeny of the other sire breeds. Cutting loss (CCW - wholesale cut weights) and high-value trimming loss were greatest (P < 0.02) for Suffolk-sired lambs and least for Texel- and Composite-sired lambs. Sire breed did not affect (P > 0.06) flank weight. Data adjusted to comparable CCW reduced the number of significant sire-breed effects and changed sire-breed rankings of carcass component weights, for which sire breeds differed. After adjusting, Suffolk-sired lambs had lighter (P < 0.05) loins than Columbia- and Composite-sired lambs, Composite-sired lambs had heavier (P < 0.05) high-value cuts than Suffolk-sired lambs, and Suffolk- and Columbia-sired lambs had heavier (P < 0.05) necks than Texel-sired lambs. At predicted backfat thickness of 6.6 mm, Composite-sired lambs had a greater (P < 0.05) percentage of high-value cuts than Suffolk-sired lambs before but not after trimming. Producers can use these results to select terminal-sire breeds that will complement their production system and improve lamb value.
Odhaib, Kifah Jumaah; Adeyemi, Kazeem Dauda; Ahmed, Muideen Adewale; Jahromi, Muhammad Faseleh; Jusoh, Shokri; Samsudin, Anjas Asmara; Alimon, Abdul Razak; Yaakub, Halimatun; Sazili, Awis Qurni
2018-06-01
The objective of this study was to determine the effects of dietary supplementation of Nigella sativa L. seeds, Rosmarinus officinalis L. leaves and their combination on rumen metabolism, nutrient intake and digestibility, growth performance, immune response and blood metabolites in Dorper lambs. Twenty-four entire male Dorper lambs (18.68 ± 0.6 kg, 4-5 months old) were randomly assigned to a concentrate mixture containing on a dry matter basis either, no supplement (control, T1), 1% R. officinalis leaves (T2), 1% N. sativa seeds (T3) or 1% R. officinalis leaves +1% N. sativa seeds (T4). The lambs had ad libitum access to urea-treated rice straw (UTRS) and were raised for 90 days. Supplemented lambs had greater (P < 0.05) intake of DM and UTRS than the control lambs. The T4 lambs had lower (P < 0.05) nutrient digestibility than those fed other treatments. Total and daily weight gain was greater (P < 0.05) in T2 lambs than those fed other diets. The T3 and T4 lambs had greater (P < 0.05) ruminal pH than the T1 and T2 lambs. Supplemented lambs had lower (P < 0.05) ruminal total volatile fatty acids, acetate, propionate, NH 3 -N and C18:0 than the control lambs. The T4 lambs had lower (P < 0.05) population of Fibrobacter succinogenes, Ruminococcus albus, methanogens and total protozoa compared with those fed other diets. Supplemented lambs had lower (P < 0.05) neutrophils, basophils and serum urea and greater (P < 0.05) serum IgA and IgG compared with the control lambs. The current results emphasised the variation in the efficacy of medicinal plants in ruminant nutrition.
Futro, Agnieszka; Masłowska, Katarzyna; Dwyer, Cathy M.
2015-01-01
Although neonatal farm animals are frequently subjected to painful management procedures, the role of maternal behaviour in pain coping, has not been much studied. We investigated whether ewes were able to distinguish between lambs in pain and those that were not, and whether their behaviour altered depending on the severity of lamb pain. Eighty male lambs were allocated to one of 4 pain treatments within 24 hours of birth. Lambs were either handled only (C), bilaterally castrated with tight rubber rings (RR), as for RR but with the application of a Burdizzo clamp immediately proximal to the ring (Combined) or subjected to short scrotum castration (SSC) where the testicles were retained within the abdomen and only the scrotum removed. The behaviour of the ewe, treated lamb and untreated sibling where present (n = 54) were recorded for 30 minutes after treatment. Castration treatment increased the expression of abnormal standing and lying postures, specific pain-related behaviours (head-turning, stamping/kicking, easing quarters, tail wagging) and composite pain scores (P<0.001 for all). The greatest expression of pain-related behaviours was shown by lambs in the RR group, which were the only group to show rolling responses indicative of severe pain, followed by the SSC group. Ewes expressed more licking/sniffing responses to the RR and SSC lambs than towards the Combined and C lambs (P<0.05), and oriented most to RR lambs and least to C lambs (P<0.001). Ewes with two lambs also directed more attention towards the treated than the untreated lamb (P<0.001). The quantity of maternal care directed towards the lamb was positively correlated with the expression of active pain behaviours. The data demonstrate that ewes are able to discriminate between lambs in pain and those that are not, and that their response is increased with a greater severity of pain. PMID:26217942
NASA Astrophysics Data System (ADS)
Akle, Barbar; Nawshin, Saila; Leo, Donald
2006-03-01
Ionomeric polymer transducers have received considerable attention in the past several years. These actuators, sometimes referred to as artificial muscles, have the ability to generate large bending strain and moderate stress at low applied voltages. Typically, ionic polymer actuators are composed of Nafion-117 membranes with platinum electrodes and are saturated with water diluents. Recently the authors have developed a novel fabrication technique named the Direct Assembly Process (DAP), which allowed good control on electrode morphology and composition. The DAP consists of spraying two high surface area metal-ionomer electrodes on a Nafion membrane. A single- walled carbon nanotubes (SWNT) and ruthenium dioxide (RuO II) hybrid electrode was sprayed on a Formamide hydrated Nafion-117 membrane using the DAP method. This transducer was shown to generate 9.4% peak-peak strain under the application of +/-2V at a strain rate of 1%/sec. Furthermore using the DAP one is capable of incorporating several types of diluents in ionomeric polymer transducers. Transducers with ionic liquid diluents are demonstrated to operate in air for long periods of time. In this work we will present a reliability study of transducers fabricated using the DAP. Each transducer is tested under a frequency range of 0.2Hz to 1Hz, and a potential of +/-1V to +/-3V. Water hydrated transducers dehydrates and stop moving within 5 minutes while operating in air under +/-2V. Transducers with Formamide diluents operate for 20,000 cycles under +/-1.5V and 0.5Hz (around 11hrs), while they degrade in less than 3000 cycles under +/-2V and 0.5Hz. Ionic liquid based transducers are demonstrated to operate in air for over 400,000 with little loss in performance, and over 1 million cycle with a loss of only 43%. Actuators with several electrode compositions are fabricated and a correlation between the reliability of ionic liquid-ionic polymer transducers and maximum strain will be presented. This correlation will be used to assess the adhesion between the high surface area electrodes and the Nafion membrane. SEM images of tested transducers will be presented.
Ekeom, Didace; Hadj Henni, Anis; Cloutier, Guy
2013-03-01
This work demonstrates, with numerical simulations, the potential of an octagonal probe for the generation of radiation forces in a set of points following a path surrounding a breast lesion in the context of dynamic ultrasound elastography imaging. Because of the in-going wave adaptive focusing strategy, the proposed method is adapted to induce shear wave fronts to interact optimally with complex lesions. Transducer elements were based on 1-3 piezocomposite material. Three-dimensional simulations combining the finite element method and boundary element method with periodic boundary conditions in the elevation direction were used to predict acoustic wave radiation in a targeted region of interest. The coupling factor of the piezocomposite material and the radiated power of the transducer were optimized. The transducer's electrical impedance was targeted to 50 Ω. The probe was simulated by assembling the designed transducer elements to build an octagonal phased-array with 256 elements on each edge (for a total of 2048 elements). The central frequency is 4.54 MHz; simulated transducer elements are able to deliver enough power and can generate the radiation force with a relatively low level of voltage excitation. Using dynamic transmitter beamforming techniques, the radiation force along a path and resulting acoustic pattern in the breast were simulated assuming a linear isotropic medium. Magnitude and orientation of the acoustic intensity (radiation force) at any point of a generation path could be controlled for the case of an example representing a heterogeneous medium with an embedded soft mechanical inclusion.
Nonlinear Lamb waves for fatigue damage identification in FRP-reinforced steel plates.
Wang, Yikuan; Guan, Ruiqi; Lu, Ye
2017-09-01
A nonlinear Lamb-wave-based method for fatigue crack detection in steel plates with and without carbon fibre reinforcement polymer (CFRP) reinforcement is presented in this study. Both numerical simulation and experimental evaluation were performed for Lamb wave propagation and its interaction with a fatigue crack on these two steel plate types. With the generation of the second harmonic, the damage-induced wave nonlinearities were identified by surface-bonded piezoelectric sensors. Numerical simulation revealed that the damage-induced wave component at the second harmonic was slightly affected by the existence of CFRP laminate, although the total wave energy was decreased because of wave leakage into the CFRP laminate. Due to unavoidable nonlinearity from the experimental environments, it was impractical to directly extract the time-of-flight of the second harmonic for locating the crack. To this end, the correlation coefficient of benchmark and signal with damage at double frequency in the time domain was calculated, based on which an imaging method was introduced to locate the fatigue crack in steel plates with and without CFRP laminates. Copyright © 2017 Elsevier B.V. All rights reserved.
Alazzeh, A Y; Abughazaleh, A A; Awawdeh, F T; Abdelrahman, M M; Al-Rayyan, N A
2009-07-01
This experiment was conducted to investigate the effect of the inclusion of saltbush (Atriplex sp.) on the productive performance and blood mineral profile of fattening lambs. Eighteen Awassi lambs, 70 +/- 3 days of age and 23 +/- 1.8 kg body weights, were randomly selected and divided into three equal groups. Lambs in group one (control) were offered 0.2 kg/day shredded straw of barley (tibin) as the sole source of roughage, while lambs in treatment groups 2 and 3 were provided either 0.2 kg/day Atriplex nummularia or Atriplex halimus as their sole roughage content for 10 weeks. All lambs were also provided 1.1 kg/day of concentrate ration. Although lambs fed A. halimus had significantly (P < 0.05) lower dry matter intake than the control group, the daily weight gain of the two groups of lambs were not significantly different (P > 0.05). Lambs fed either A. nummularia or A. halimus had significantly lower (P < 0.05) calcium and copper levels but significantly higher (P < 0.05) cobalt levels in their blood serum than the control group. Zinc blood serum level was not affected (P > 0.05) by the treatment diets. These results suggested that A. nummularia and A. halimus can substitute for barley straw in the ration of fattening Awassi lambs without compromising lambs weight gain; however, special attention should be given to the mineral status in lambs if saltbush is a major feed component for prolonged periods of time.
IEEE 1451.2 based Smart sensor system using ADuc847
NASA Astrophysics Data System (ADS)
Sreejithlal, A.; Ajith, Jose
IEEE 1451 standard defines a standard interface for connecting transducers to microprocessor based data acquisition systems, instrumentation systems, control and field networks. Smart transducer interface module (STIM) acts as a unit which provides signal conditioning, digitization and data packet generation functions to the transducers connected to it. This paper describes the implementation of a microcontroller based smart transducer interface module based on IEEE 1451.2 standard. The module, implemented using ADuc847 microcontroller has 2 transducer channels and is programmed using Embedded C language. The Sensor system consists of a Network Controlled Application Processor (NCAP) module which controls the Smart transducer interface module (STIM) over an IEEE1451.2-RS232 bus. The NCAP module is implemented as a software module in C# language. The hardware details, control principles involved and the software implementation for the STIM are described in detail.
[Study of the pathogenesis of paecilomycosis-complicated echinococcosis].
Abdiev, F T; Mamysheva, N O; Streliaeva, A V; Gasparian, E R; Sagieva, A T; Sadykov, R V; Lazareva, N B; Kurilov, D V; Akhmedov, Iu M; Sadykov, V M; Shcheglova, T A; Zuev, S S; Mukhitdinov, Sh M; Vakhidova, A V
2012-01-01
Experiments were carried out on 35 lambs infected with echinococcus eggs taken from canine donors, 5 lambs with echinococcosis, 5 lambs with echinococcosis + paecilomycosis, 5 lambs with coenurosis, 5 with cysticercosis ovis, 5 with alveococcosis, 5 with paecilomycosis, inoculated by the material taken from patients; and 5 healthy lambs formed a control group. Cystic hydatidosis was found to induce substantial cardiovascular changes.
An Extracorporeal Artificial Placenta Supports Extremely Premature Lambs for One Week
Bryner, Benjamin; Gray, Brian; Perkins, Elena; Davis, Ryan; Hoffman, Hayley; Barks, John; Owens, Gabe; Bocks, Martin; Rojas-Peña, Alvaro; Hirschl, Ronald; Bartlett, Robert; Mychaliska, George
2015-01-01
Purpose The treatment of extreme prematurity remains an unsolved problem. We developed an artificial placenta (AP) based on extracorporeal life support (ECLS) that simulates the intrauterine environment and provides gas exchange without mechanical ventilation (MV), and compared it to the current standard of neonatal care. Methods Extremely premature lambs (110-120d; term=145d) were used. AP lambs (n=9) were cannulated (jugular drainage, umbilical vein reinfusion) for ECLS .Control lambs (n=7) were intubated, ventilated, given surfactant, and transitioned to high-frequency oscillatory ventilation. All lambs received parenteral nutrition, antibiotics, and steroids. Hemodynamics, blood gases, hemoglobin, and circuit flows were measured. Results Four premature lambs survived for 1 week on the AP; one survived 6 days. Adequate oxygenation and ventilation were provided by the AP. The MV lambs survived 2-8 hours. Each of these lambs experienced a transient improvement with surfactant, but developed progressive hypercapnea and hypoxia despite high airway pressures and HFOV. Conclusions Extremely premature lambs were supported for 1 week with the AP with hemodynamic stability and adequate gas exchange; mechanically ventilated lambs succumbed within 8 hours. Further studies will assess control of fetal circulation and organ maturation on the AP. PMID:25598091
Effect of morning vs. afternoon grazing on intramuscular fatty acid composition in lamb.
Vasta, Valentina; Pagano, Renato Italo; Luciano, Giuseppe; Scerra, Manuel; Caparra, Pasquale; Foti, Francesco; Cilione, Caterina; Biondi, Luisa; Priolo, Alessandro; Avondo, Marcella
2012-01-01
The aim of this study was to assess whether different grazing management affect animal performance and meat fatty acid composition. Thirty-five lambs were divided into three groups: 12 lambs grazed from 9 am to 5 pm (8 h group); 11 lambs grazed from 9 am to 1 pm (4hAM group) and 12 lambs grazed from 1 pm to 5 pm (4hPM group). The trial was conducted over 72 days. The 8 h lambs had greater DMI (P<0.0005) and final body weight (P<0.05) than the 4hPM and 4hAM lambs while carcass weight was not different between the three groups. The meat of the 4hPM lambs contained greater (P<0.05) percentages of polyunsaturated fatty acids, C18:2 cis-9 trans-11 and lower saturated fatty acids and C18:0 than the meat of the 8 h and 4hAM lambs. It is concluded that allowing lambs to graze during the afternoon rather than during 8 h does not compromise the carcass yield and results in a healthier meat fatty acid profile. Copyright © 2011 Elsevier Ltd. All rights reserved.
Lakshminrusimha, Satyan; Wedgwood, Stephen; Czech, Lyubov; Gugino, Sylvia F.; Russell, James A.; Farrow, Kathryn N.; Steinhorn, Robin H.
2012-01-01
In the pulmonary vasculature, cGMP levels are regulated by soluble guanylate cyclase (sGC) and phosphodiesterase 5 (PDE5). We previously reported that lambs with persistent pulmonary hypertension of the newborn (PPHN) demonstrate increased reactive oxygen species (ROS) and altered sGC and PDE5 activity, with resultant decreased cGMP. The objective of this study was to evaluate the effects of hydrocortisone on pulmonary vascular function, ROS, and cGMP in the ovine ductal ligation model of PPHN. PPHN lambs were ventilated with 100% O2 for 24 h. Six lambs received 5 mg/kg hydrocortisone every 8 h times three doses (PPHN-hiHC), five lambs received 3 mg/kg hydrocortisone followed by 1 mg·kg−1·dose−1 times two doses (PPHN-loHC), and six lambs were ventilated with O2 alone (PPHN). All groups were compared with healthy 1-day spontaneously breathing lambs (1DSB). O2 ventilation of PPHN lambs decreased sGC activity, increased PDE5 activity, and increased ROS vs. 1DSB lambs. Both hydrocortisone doses significantly improved arterial-to-alveolar ratios relative to PPHN lambs, decreased PDE5 activity, and increased cGMP relative to PPHN lambs. High-dose hydrocortisone also increased sGC activity, decreased PDE5 expression, decreased ROS, and increased total vascular SOD activity vs. PPHN lambs. These data suggest that hydrocortisone treatment in clinically relevant doses improves oxygenation and decreases hyperoxia-induced changes in sGC and PDE5 activity, increasing cGMP levels. Hydrocortisone reduces ROS levels in part by increasing SOD activity in PPHN lambs ventilated with 100% O2. We speculate that hydrocortisone increases cGMP by direct effects on sGC and PDE5 expression and by attenuating abnormalities induced by oxidant stress. PMID:22198909
Liu, Shimin; Lei, Jason; Hancock, Serina; Scanlan, Victoria; Broomfield, Steve; Currie, Andrew; Thompson, Andrew
2016-10-01
Wool growth in Merino sheep demands a high level of sulphur amino acids, competing with body growth and the immune system, which may play a role in increasing the risk of lamb mortality. The hypothesis that dietary supplementation of methionine (Met) to Merino ewes during the late stages of pregnancy will improve foetal growth and alter immune competency of ewes and lambs was tested in a total of 120 grazing, pregnant Merino ewes. Sixty ewes were group-supplemented with 6.3 g/d rumen-protected Met (Met-Plus) per sheep from day 111 of pregnancy until day 7 after lambing, and the other 60 animals were used as a non-supplemented Control. Lambs from Met-supplemented ewes tended to be 10% heavier than Control lambs (p = 0.10), which did not affected the survival rate at weaning significantly. The supplemented ewes had slightly higher concentrations of total glutathione (GSH) in plasma at lambing (p < 0.06), but there were no differences between 1 and 3 months post-lambing in GSH, glutathione disulphide (GSSG) and the GSSG:GSH ratio. The GSSG:GSH ratio in the blood of ewes was elevated at lambing (p < 0.05), hinting that ewes were undergoing increased oxidative stress. The Met supplementation elevated the total IgG concentration (p < 0.05) in lambs aged 4 and 6 weeks, but did not change the IgG concentrations in colostrum and in plasma of 1-week-old lambs, and white blood cell counts and leukocyte types. The trend towards higher lamb birth weights in the Met-supplemented group requires further investigation as this may influence survival at birth and weaning.
Genetic parameters for lamb birth weight, survival and death risk traits.
Everett-Hincks, J M; Mathias-Davis, H C; Greer, G J; Auvray, B A; Dodds, K G
2014-07-01
This paper reports genetic parameters for lamb survival and mortality traits on sheep farms in New Zealand. Lamb survival and mortality records were obtained from 38 flocks (103,357 lambs) from 5 yr of lambing data (2007 to 2011) and include many breeds and their crosses (predominantly Romney, Perendale, Coopworth, and Texel). A number of models were tested, all including environmental weather effects and investigating the random environmental effect of dam and litter (dam/year) as well as logit transformation for binary traits. Total heritability (direct + maternal) estimates were low for lamb viability at birth (0.01), lamb death risk to dystocia (0.01), and lamb death risk to starvation exposure (0.01) from birth to 3 d of age in an analysis accounting for direct and maternal genetic effects and the maternal environmental effects. Lamb survival heritabilities reported are very low (total heritabilities range from 0.02 to 0.06). The total heritabilities for the lamb death risk traits are lower than reported estimates of survival to 3 d of age or to weaning suggesting selection for the postmortem traits are not warranted at this time within these flocks. The total heritability for lamb birth weight was moderate (0.38) and the genetic correlations with the lamb death risk traits suggested that directional selection on lamb birth weight would have an effect on survival, although it is likely to have a nonlinear effect and therefore an optimum birth weight at which survival is maximized. This study has also shown that the total heritabilities may be overestimated when not accounting for maternal genetic and environment effects and in particular not accounting for the random environmental effect of litter (dam/year).
Linlor, W.I.; Kerns, Q.A.
1960-11-15
A system is given for detecting incremental changes in a transducer impedance terminating a transmission line. Principal novelty resides in the transducer impedance terminating the line in a mismatch and a pulse generator being provided to apply discrete pulses to the input end of the line. The amplitudes of the pulses reflected to the input end of the line from the mismatched transducer impedance are then observed as a very accurate measure of the instantaneous value of the latter.
Development of dynamic calibration methods for POGO pressure transducers. [for space shuttle
NASA Technical Reports Server (NTRS)
Hilten, J. S.; Lederer, P. S.; Vezzetti, C. F.; Mayo-Wells, J. F.
1976-01-01
Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.
NASA Astrophysics Data System (ADS)
Dreyer, Uilian José; Vagner da Silva, Erlon; Martelli, Cicero; Cardozo da Silva, Jean Carlos
2017-08-01
In this paper, we propose a new multiparametric optical fiber transducer applied to an electric generator of 370 MVA. The optical transducer has three multiplexed FBGs in the same optical fiber as the sensing element. The FBG sensors can simultaneously measure both the temperature and vibration independently of the other multiplexed FBGs. The installation in the power plant was performed using six transducers and it was obtained 23 hours of simultaneous vibration and temperature measurement. All the FBGs used to monitor generator vibration were able to monitor the frequency of mechanical and electromagnetic vibrations, which were measured at 2 Hz and 120 Hz, respectively. During the measurement, the machine was turned off due to a failure and all the FBGs sensed temperature changes, as well as frequency vibration changes. The largest temperature difference measured between the FBGs during the test is approximately 2°C.
Wańkowska, Marta; Polkowska, Jolanta; Misztal, Tomasz; Romanowicz, Katarzyna
2012-07-01
The aim of the study was to elucidate the effects of ovarian hormones on somatostatin in the hypothalamic neurons and growth hormone (GH) secretion during the postnatal growth and development of sheep. The study was performed on 9-week-old (infantile) lambs that were ovary-intact (OVI) or ovariectomized (OVX) at 39 days of age, and on 16-week-old (juvenile) lambs that were OVI or OVX at 88 days of age. Hormones in neurons and somatotropic cells were assayed with immunohistochemistry and radioimmunoassay. Following ovariectomy, immunoreactive somatostatin was more abundant (p<0.05) in the hypothalamus of infantile lambs, whereas in juvenile lambs it was more abundant (p<0.05) in the periventricular nucleus but reduced (p<0.01) in the median eminence. In contrast to somatostatin in the hypothalamus, the content of immunoreactive GH in the hypophysis was less in OVX infantile lambs, but greater in OVX juvenile lambs (p<0.05). Basal blood serum concentrations of GH were greater (p<0.05) in OVX infantile lambs, whereas in OVX juvenile lambs, mean and basal concentrations of GH and amplitude of GH pulses were less than in OVI lambs (p<0.05). The postnatal increase in body weight was greatest in middle-late infancy (p<0.01). The body weight did not differ (p>0.05) between OVI and OVX lambs. In conclusion, ovarian factors may inhibit the GH secretion in infantile lambs but enhance the GH secretion in juvenile lambs. Transition to puberty, as related to the growth rate, appears to be due mainly to change in gonadal influence on the somatostatin neurosecretion. A stimulation of somatostatin output in the median eminence by gonadal factors in infancy is followed by a stimulation of somatostatin accumulation after infancy. Thus, ovarian factors modulate mechanisms within the somatotropic system of lambs to synchronize the somatic growth with sexual development. Copyright © 2012 Elsevier B.V. All rights reserved.
Gronqvist, Gabriella V; Corner-Thomas, Rene A; Kenyon, Paul R; Stafford, Kevin J; Morris, Stephen T; Hickson, Rebecca Edith
2018-04-12
Triplet-born lambs are less likely to survive to weaning than twin-born or single-born lambs. Appropriate ewe-lamb bonding behaviours and lamb vigour behaviours are necessary for survival of lambs. The aim of this experiment was to determine whether maternal nutrition during late pregnancy influenced behaviour of the ewe and her lambs soon after birth, and to determine whether mid-pregnancy body condition score (BCS) influenced any behavioural response. The experiments included ewes that were in BCS 2.0, 2.5 or 3.0 in mid-pregnancy and were fed either ad libitum or to pregnancy-maintenance requirements in late-pregnancy (day 115 until 136 in experiment one, and day 128 until 141 in experiment two). The time taken for lambs to stand, contact dam, suck from dam and follow dam was recorded three to 18 hours after birth. The number of high- and low-pitched bleats emitted by the ewe and lambs was recorded, along with maternal behaviour score (MBS) of the ewe. Lambs in experiment two underwent a maternal-recognition test at 12 or 24 h. There were significant effects of feeding treatment on bleating behaviour of ewes and lambs, but these were inconsistent among BCS groups and between experiments. Lamb vigour behaviours were not affected by feeding treatment. In experiment one, there was no effect of feeding treatment or BCS on MBS, but in experiment two, ewes in BCS3 in mid-pregnancy had greater MBS than ewes in BCS2 in mid-pregnancy (MBS 3.1/5 vs MBS 2.1/5; P<0.05). Given there were no repeatable effects on behaviour of ewes and lambs, ad libitum feeding rather than feeding for pregnancy-maintenance requirements can not be used to improve behaviours soon after birth of triplet-bearing ewes in BCS 2 - 3 and their lambs in extensive pastoral conditions.
Performance of Djallonké sheep under an extensive system of production in Faranah, Guinea.
Mourad, M; Gbanamou, G; Balde, I B
2001-10-01
A total of 147 ewes, 4 rams and 188 lambs of their progeny of the Djallonké breed of sheep were used to study the factors affecting reproductive and growth traits and the causes of lamb mortality. Data on ewes were collected during a 12-month period, while those on the lambs born to 123 of the ewes were collected until they were 12 months of age. The average fertility and abortion rates were 0.84 and 0.09. The fertility rate increased and the abortion rate decreased with increasing age of the ewes (p<0.05). The number of lambs born per ewe joined, litter weight at birth per ewe joined and litter weight at weaning per ewe joined were 1.28, 3.5 kg and 17 kg, respectively. The average numbers of lambs born per ewe, lambs born alive per ewe, lambs born dead per ewe and lambs per ewe that died between birth and weaning were 1.53, 1.43, 0.03 and 0.3, respectively. The age of the ewes significantly (p<0.05) affected all these traits except the number of dead lambs and the index of fertility (94%). The age of the ewes significantly (p<0.05) affected the birth weight and the weight at 6 and 12 months of age, whereas the lambing season significantly (p<0.05) affected all the growth traits studied. The type of birth was the most important source of variation in body weights of lambs. Sex had no significant (p>0.05) effect on the growth traits studied. The complex 'starvation-bad management-light body weight at birth' caused 48% of the lamb mortality between birth and weaning, while diarrhoea, pneumonia and internal and external parasites caused approximately 52% of the lamb mortality over the same period. The seasonal raw mortality rate of the lambs before weaning was highest in the humid season.
High-frequency guided ultrasonic waves to monitor corrosion thickness loss
NASA Astrophysics Data System (ADS)
Fromme, Paul; Bernhard, Fabian; Masserey, Bernard
2017-02-01
Corrosion due to adverse environmental conditions can occur for a range of industrial structures, e.g., ships and offshore oil platforms. Pitting corrosion and generalized corrosion can lead to the reduction of the strength and thus degradation of the structural integrity. The nondestructive detection and monitoring of corrosion damage in difficult to access areas can be achieved using high frequency guided ultrasonic waves propagating along the structure. Using standard ultrasonic transducers with single sided access to the structure, the two fundamental Lamb wave modes were selectively generated simultaneously, penetrating through the complete thickness of the structure. The wave propagation and interference of the guided wave modes depends on the thickness of the structure. Numerical simulations were performed using a 2D Finite Difference Method (FDM) algorithm in order to visualize the guided wave propagation and energy transfer across the plate thickness. Laboratory experiments were conducted and the wall thickness reduced initially uniformly by milling of the steel structure. Further measurements were conducted using accelerated corrosion in salt water. From the measured signal change due to the wave mode interference, the wall thickness reduction was monitored and good agreement with theoretical predictions was achieved. Corrosion can lead to non-uniform thickness reduction and the influence of this on the propagation of the high frequency guided ultrasonic waves was investigated. The wave propagation in a steel specimen with varying thickness was measured experimentally and the influence on the wave propagation characteristics quantified.
Mineral composition of lamb carcasses from the United States and New Zealand.
Lin, K C; Cross, H R; Johnson, H K; Breidenstein, B C; Randecker, V; Field, R A
1988-01-01
The mineral composition-iron (Fe), zinc (Zn), copper (Cu), calcium (Ca), magnesium (Mg), sodium (Na), potassium (K), fluoride (F), and phosphorus (P) (New Zealand lamb only)-of lean tissue from lamb retail cuts was studied. Twenty-four US lamb carcasses of different ages (5 to 11 months), geographical regions (Texas, Colorado and Montana) and USDA quality grades (Prime and Choice) and 27 New Zealand lamb carcasses from three weight groups (11 to 12·5 kg, 13 to 14·5 kg, and 16·5 to 18 kg), age rangining from 7 to 8 months, were selected for use in this study. Mineral concentrations were influenced more by retail cut and age than by quality grade or weigth group. Foreshank and shoulder cuts from both the US and New Zealand group consistently had the highest (P < 0·05) Zn content among the cuts. The K content of the muscle in US lambs increased as age increased, while the level of Ca and Zn in New Zealand lambs decreased as carcass weight increased. Except for Ca, the mineral concentrations of the lean tissue from US lambs were higher than the New Zealand lambs, although the differences were not always significant. US lambs had approximately 20%, 30% and 37% more Fe, Zn and Mg, respectively, but 27% less Ca than lean tissue from the New Zealand lambs. Copyright © 1989. Published by Elsevier Ltd.
Thermacoustic piezoelectric generator
Keolian; Robert M. , Wuthrich; John W. , Bastyr; Kevin J.
2010-08-10
An electroactive transducer converts between acoustical power and electrical power. The transducer includes a diaphragm and a perimeter member. The perimeter member includes at least one electroactive element and is mechanically coupled to the perimeter of the diaphragm such that displacement of the diaphragm stresses the electroactive element.
A New Omni-Directional EMAT for Ultrasonic Lamb Wave Tomography Imaging of Metallic Plate Defects
Huang, Songling; Wei, Zheng; Zhao, Wei; Wang, Shen
2014-01-01
This paper proposes a new omni-directional electromagnetic acoustic transducer (EMAT) for the ultrasonic Lamb wave (ULW) tomography imaging (TI) of defects in metallic plates. The proposed EMAT is composed of a permanent magnet and a coil with a contra-flexure structure. This new EMAT coil structure is used for omni-directional ULW transmission and reception and ULW TI for the first time. The theoretical background and the working principles of this EMAT are presented and analyzed. The experimental results of its use on a 3 mm thick aluminum plate indicate that the EMAT with a contra-flexure coil (CFC) can transmit and receive a pure single A0 mode ULW with a high signal-to-noise ratio (SNR). Thus, the extraction of the projection data used for ULW TI may be performed accurately. The circumferential consistency of the projection data is only slightly influenced by the distortion of the eddy current field that is induced by the new CFC with an irregular shape. When the new EMAT array is used for ULW TI using the cross-hole method and SIRT arithmetic, a desirable imaging quality can be achieved, and the estimated size of an artificial corrosion defect agreed well with its actual value. The relation between the reconstruction resolution and the number of the new EMATs used is analyzed. More TI experiments are carried out when the aluminum plate defect is in two different locations relative to the EMAT array, for the further investigation of the performances of the new EMATs. PMID:24561398
Genetic evaluation of weaning weight and probability of lambing at 1 year of age in Targhee lambs
USDA-ARS?s Scientific Manuscript database
The objective of this study was to investigate genetic control of 120-day weaning weight and the probability of lambing at 1 year of age in Targhee ewe lambs. Records of 5,967 ewe lambs born from 1989 to 2012 and first exposed to rams for breeding at approximately 7 months of age were analyzed. Reco...
Dwyer, C M
2008-04-01
The relatively intensive supervision afforded many ewes at lambing time is a barrier to the development of low-input sheep management systems. However, in some flocks, reduction in this level of supervision may initially affect lamb mortality and animal welfare. In this review, possibilities for optimizing behavioral interaction between the ewe and lamb are considered, with the goal of improving lamb survival without the need for high levels of human supervision. At birth, ewes show specific behavioral patterns (e.g., licking or grooming, low-pitched bleats, udder acceptance) that facilitate the transition of the lamb from pre- to postnatal life and that accompany the formation of an exclusive olfactory memory for the lamb. The lamb also performs a specific sequence of behaviors directed toward standing, finding the udder, and sucking. The successful accomplishment of these behavior patterns is vital for the formation of a strong attachment between both partners, and for lamb survival. The expression of maternal behavior in the ewe is affected by her previous maternal experience, by nutrition in pregnancy, by breed, by temperament, and, to some extent, by the behavior of her lamb. The maternal care expressed by a ewe at parturition is indicative of her behavior throughout that lactation and in successive pregnancies, suggesting an underlying basis to maternal care intrinsic to that ewe. Studies with Scottish Blackface and Suffolk ewes show that ewes expressing high levels of maternal care have elevated plasma estradiol in late gestation compared with ewes with poorer maternal care, and that circulating estradiol concentration is correlated with maternal behaviors. Although the genetic basis of maternal behaviors has still to be fully determined, there are possibilities of improving maternal behavior by selection, and a better understanding of the neuroendocrine processes underlying individual differences in maternal behavior may help in developing selection strategies. In addition, selection on lamb behaviors, which show some genetic basis, may also be a route to improve lamb survival. Because behavior of both the ewe and lamb is affected by environmental factors, appropriate management, through pregnancy and at parturition, will enhance the expression of maternal behavior and lamb vigor, and so contribute to improving lamb survival.
Development of lightweight structural health monitoring systems for aerospace applications
NASA Astrophysics Data System (ADS)
Pearson, Matthew
This thesis investigates the development of structural health monitoring systems (SHM) for aerospace applications. The work focuses on each aspect of a SHM system covering novel transducer technologies and damage detection techniques to detect and locate damage in metallic and composite structures. Secondly the potential of energy harvesting and power arrangement methodologies to provide a stable power source is assessed. Finally culminating in the realisation of smart SHM structures. 1. Transducer Technology A thorough experimental study of low profile, low weight novel transducers not normally used for acoustic emission (AE) and acousto-ultrasonics (AU) damage detection was conducted. This included assessment of their performance when exposed to aircraft environments and feasibility of embedding these transducers in composites specimens in order to realise smart structures. 2. Damage Detection An extensive experimental programme into damage detection utilising AE and AU were conducted in both composites and metallic structures. These techniques were used to assess different damage mechanism within these materials. The same transducers were used for novel AE location techniques coupled with AU similarity assessment to successfully detect and locate damage in a variety of structures. 3. Energy Harvesting and Power Management Experimental investigations and numerical simulations were undertaken to assess the power generation levels of piezoelectric and thermoelectric generators for typical vibration and temperature differentials which exist in the aerospace environment. Furthermore a power management system was assessed to demonstrate the ability of the system to take the varying nature of the input power and condition it to a stable power source for a system. 4. Smart Structures The research conducted is brought together into a smart carbon fibre wing showcasing the novel embedded transducers for AE and AU damage detection and location, as well as vibration energy harvesting. A study into impact damage detection using the techniques showed the successful detection and location of damage. Also the feasibility of the embedded transducers for power generation was assessed..
The passive transfer of immunity to Taenia ovis in lambs via colostrum.
Sutton, R J
1979-09-01
Colostrum from ewes that had been repeatedly exposed to cestode infection, whether or not their immunity was boosted by vaccination with Taenia ovis, transferred a strong immunity to the lambs. Susceptible ewes, not recently exposed to tapeworm eggs, gave no protection to their lambs via the colostrum. There was no evidence that colostrum-deprived lambs were more susceptible to infection with T ovis than lambs that received colostrum from non-immune ewes. Colostrum from naturally immune vaccinated ewes gave good protection to lambs for up to six weeks but thereafter the effect was variable. The immunity that developed in susceptible ewes after vaccination with activated embryos was not passed on to the lambs via the colostrum.
Lamb Wave Assessment of Fiber Volume Fraction in Composites
NASA Technical Reports Server (NTRS)
Seale, Michael D.; Smith, Barry T.; Prosser, W. H.; Zalameda, Joseph N.
1998-01-01
Among the various techniques available, ultrasonic Lamb waves offer a convenient method of examining composite materials. Since the Lamb wave velocity depends on the elastic properties of a material, an effective tool exists to evaluate composites by measuring the velocity of these waves. Lamb waves can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper discusses a study in which Lamb waves were used to examine fiber volume fraction variations of approximately 0.40-0.70 in composites. The Lamb wave measurements were compared to fiber volume fractions obtained from acid digestion tests. Additionally, a model to predict the fiber volume fraction from Lamb wave velocity values was evaluated.
7 CFR 1280.210 - Powers and duties of the Board.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion... (including producer information), designed to strengthen the lamb industry's position in the marketplace...
7 CFR 1280.201 - Establishment and membership.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion... Lamb Promotion, Research and Information Board of 13 members. Members of the Board shall be appointed...
Breeding objectives for Targhee sheep.
Borg, R C; Notter, D R; Kuehn, L A; Kott, R W
2007-11-01
Breeding objectives were developed for Targhee sheep under rangeland production conditions. Traits considered were those for which EPD were available from the US National Sheep Improvement Program and included direct and maternal effects on 120-d weaning weight (WW and MM, respectively); yearling weight (YW); yearling fleece weight, fiber diameter, and staple length; and percent lamb crop (PLC), measured as the number of lambs born per 100 ewes lambing. A bioeconomic model was used to predict the effects of a change of 1 additive SD in EPD for each trait, holding all other traits constant at their mean, on animal performance, feed requirements, feed costs, and economic returns. Resulting economic weightings were then used to derive selection indexes. Indexes were derived separately for 3 prolificacy levels (1.41, 1.55, and 1.70 lambs/ewe lambing), 2 triplet survival levels (50 and 67%), 2 lamb pricing policies (with or without discounting of prices for heavy feeder lambs), and 3 forage cost scenarios (renting pasture, purchasing hay, or reducing flock size to accommodate increased nutrient requirements for production). Increasing PLC generally had the largest impact on profitability, although an increase in WW was equally important, with low feed costs and no discounting of prices for heavy feeder lambs. Increases in PLC were recommended at all 3 prolificacy levels, but with low triplet survival the value of increasing PLC eventually declined as the mean litter size increased to approximately 2.15 lambs/ewe lambing and above. Increasing YW (independent of WW) increased ewe maintenance costs and reduced profitability. Predicted changes in breeding values for WW and YW under index selection varied with lamb pricing policy and feed costs. With low feed costs or no discounts for heavy lambs, YW increased at a modest rate in association with increasing WW, but with high feed costs or discounting of heavy lambs, genetic trends in WW were reduced by approximately 50% to constrain increases in YW. Changes in EPD for MM or fleece traits generally had smaller effects on profitability than changes in PLC, WW, and YW. Two indexes designed to address current rangeland production conditions (low forage costs and discounting of heavy feeder lambs) or more intensive and integrated production with retained ownership and value-based marketing of lambs (higher forage costs and no discounting of heavy lambs) were anticipated to meet the needs of most Targhee producers.
Gholami, Mohammad Amin; Forouzmand, Masihollah; Khajavi, Mokhtar; Hossienifar, Shima; Naghiha, Reza
2018-01-01
The purpose of this study was to investigate the effect of different corn processing methods on rumen microbial flora, histomorphometry and fermentation in fattening male lambs. Twenty male lambs (average age and weight of 90 days and 25.00 ± 1.10 kg, respectively) were used in a completely randomized design including four treatments and five replicates each over 80 days long period: 1) Lambs fed ground corn seeds; 2) Lambs fed steam-rolled corn; 3) Lambs fed soaked corn seeds (24 hr) and 4) Lambs fed soaked corn seeds (48 hr). At the end of the experiment, three lambs of each treatment were slaughtered and samples were collected for pH, volatile fatty acids, amylolytic, proteolytic, cellulytic and heterophilic bacteria and protozoa assessment. The number of proteolytic bacteria in soaked corn seeds was significantly increased in comparison with other treatments. The thickness of wall, papillae and muscular layers of rumen in the soaked corn seeds treatment was significantly increased. Overall, from a practical point of view, soaked corn processing could be generally used in lambs fattening system. PMID:29719663
Thermal effects on transducer material for heat assisted magnetic recording application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Rong, E-mail: Ji-Rong@dsi.a-star.edu.sg; Xu, Baoxi; Cen, Zhanhong
2015-05-07
Heat Assisted Magnetic Recording (HAMR) is a promising technology for next generation hard disk drives with significantly increased data recording capacities. In HAMR, an optical near-field transducer (NFT) is used to concentrate laser energy on a magnetic recording medium to fulfill the heat assist function. The key components of a NFT are transducer material, cladding material, and adhesion material between the cladding and the transducer materials. Since transducer materials and cladding materials have been widely reported, this paper focuses on the adhesion materials between the Au transducer and the Al{sub 2}O{sub 3} cladding material. A comparative study for two kindsmore » of adhesion material, Ta and Cr, has been conducted. We found that Ta provides better thermal stability to the whole transducer than Cr. This is because after thermal annealing, chromium forms oxide material at interfaces and chromium atoms diffuse remarkably into the Au layer and react with Au to form Au alloy. This study also provides insights on the selection of adhesion material for HAMR transducer.« less
Airborne ultrasonic transducer using polymer-based elastomer with high output-to-weight ratio
NASA Astrophysics Data System (ADS)
Wu, Jiang; Mizuno, Yosuke; Tabaru, Marie; Nakamura, Kentaro
2015-08-01
With the properties of low density, low elastic modulus, and low mechanical loss, poly(phenylene sulfide) (PPS) is a suitable material as the elastomer in an airborne ultrasonic transducer for generating large vibration velocity. In this study, we design and fabricate a transducer composed of a PPS-based longitudinal vibrator and a PPS-based disk of 0.3 mm thickness to obtain high-intensity ultrasound. The rated sound pressure at a distance of 300 mm reached 38.9 Pa (125 dB, 0 dB re. 0.02 mPa) when the frequency and voltage were 58.90 kHz and 20 V. The weight of this transducer is 6.3 g. The ratio of the sound pressure to the weight of the prototype transducer is 1.8 times larger than that of the commercial transducer. The experimental results indicate that PPS is a good substitute for metal as the elastomer for manufacturing airborne ultrasonic transducers with a high output-to-weight ratio.
High energy, low frequency, ultrasonic transducer
Brown, Albert E.
2000-01-01
A wide bandwidth, ultrasonic transducer to generate nondispersive, extensional, pulsed acoustic pressure waves into concrete reinforced rods and tendons. The wave propagation distance is limited to double the length of the rod. The transducer acoustic impedance is matched to the rod impedance for maximum transfer of acoustic energy. The efficiency of the transducer is approximately 60 percent, depending upon the type of active elements used in the transducer. The transducer input energy is, for example, approximately 1 mJ. Ultrasonic reflections will occur at points along the rod where there are changes of one percent of a wavelength in the rod diameter. A reduction in the rod diameter will reflect a phase reversed echo, as compared with the reflection from an incremental increase in diameter. Echo signal processing of the stored waveform permits a reconstruction of those echoes into an image of the rod. The ultrasonic transducer has use in the acoustic inspection of long (40+foot) architectural reinforcements and structural supporting members, such as in bridges and dams.
Characterization of noncontact piezoelectric transducer with conically shaped piezoelement
NASA Technical Reports Server (NTRS)
Williams, James H., Jr.; Ochi, Simeon C. U.
1988-01-01
The characterization of a dynamic surface displacement transducer (IQI Model 501) by a noncontact method is presented. The transducer is designed for ultrasonic as well as acoustic emission measurements and, according to the manufacturer, its characteristic features include a flat frequency response range which is from 50 to 1000 kHz and a quality factor Q of less than unity. The characterization is based on the behavior of the transducer as a receiver and involves exciting the transducer directly by transient pulse input stress signals of quasi-electrostatic origin and observing its response in a digital storage oscilloscope. Theoretical models for studying the response of the transducer to pulse input stress signals and for generating pulse stress signals are presented. The characteristic features of the transducer which include the central frequency f sub o, quality factor Q, and flat frequency response range are obtained by this noncontact characterization technique and they compare favorably with those obtained by a tone burst method which are also presented.
7 CFR 1280.117 - Producer information.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.117 Producer information..., or other information that would facilitate an increase in the demand for lambs or lamb products. ...
USDA-ARS?s Scientific Manuscript database
This study estimated genetic parameters for ewe reproductive traits [number of lambs born (NLB) and weaned (NLW) per ewe lambing] and peri-parturient (PPR) fecal egg counts (FEC) at lambing (PPR0) and 30 d postpartum (PPR30), and their genetic relationships with lamb BW and FEC in Katahdin sheep. Th...
Interaction of Lamb Waves with Fatigue Cracks in Aluminum
2011-09-01
Interaction of Lamb Waves with Fatigue Cracks in Aluminum E. D. SWENSON, C. T. OWENS and C. ALLEN ABSTRACT Elastic waves can travel across...the interaction of Lamb waves with both open and closed low-cycle fatigue cracks in aluminum plates using a three-dimensional laser Doppler vibrometer...and antisymmetric Lamb wave modes differ upon encountering fatigue cracks. INTRODUCTION The use of guided elastic waves (Lamb waves) has shown
Miller, C M; Ganesh, S; Garland, C B; Leathwick, D M
2015-07-01
To measure the magnitude and variability in production responses to anthelmintic treatments administered to adult ewes around lambing. Ewes carrying twin lambs, from sheep and beef farms (eight in Year 1 and six in Year 2) in the Wairarapa region of New Zealand, were enrolled in 14 trials (part of an experiment carried out on one farm in one year). Experiment 1 compared ewes treated 2-4 weeks pre-lambing with a controlled release capsule (CRC) containing abamectin, albendazole, Se and Co, to ewes injected pre-lambing with a long-acting Se plus vitamin B12 product, and to untreated ewes. Experiment 2 included these treatments, plus a CRC administered at pregnancy scanning. Experiment 3 included the same treatments as Experiment 1, plus administration of a CRC containing albendazole, Se and Co, injectable moxidectin or oral derquantel plus abamectin, all administered pre-lambing, or oral derquantel plus abamectin administered 4-6 weeks after lambing. Variables compared were ewe liveweight at weaning and pre-mating, lamb liveweight at weaning, total weight of lamb weaned per ewe and ewe dag score at weaning. Ewes treated with a CRC pre-lambing were heavier than untreated ewes (mean 3.2 kg) at weaning in 12/14 trials, and pre-mating (mean 2.8 kg) in 9/14 trials (p<0.001). Compared with mineral-treated ewes the mean difference was 2.8 kg pre-lambing (9/14 trials) and 1.7 kg pre-weaning (6/14 trials). Lambs reared by treated ewes were heavier (mean 1.55 kg) at weaning in 6/14 trials (p<0.001), but there was no effect of CRC treatment on total weight of lambs weaned per ewe (p=0.507). Variation in weight of lamb weaned per ewe was largely explained by differences in lamb survival from birth to weaning (p<0.001), with no effect of CRC treatment (p>0.65). Treatment of ewes with a CRC at pregnancy scanning was neither better nor worse than a pre-lambing treatment (p=0.065). There was no difference in the response from treatment with either of the two CRC or moxidectin. Treatment with short-acting oral anthelmintics resulted in no consistent benefit. Anthelmintic treatments administered to ewes around lambing resulted in variable responses between farms and years, which in some trials were negative for some variables, and some of the variability was due to the mineral component of the CRC. The widespread perception amongst farmers and veterinarians that anthelmintic treatment of ewes around lambing will always result in positive benefits is not supported.
Embedded Ultrasonic Transducers for Active and Passive Concrete Monitoring
Niederleithinger, Ernst; Wolf, Julia; Mielentz, Frank; Wiggenhauser, Herbert; Pirskawetz, Stephan
2015-01-01
Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer’s axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature, …) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences. PMID:25923928
Neville, T L; Caton, J S; Hammer, C J; Reed, J J; Luther, J S; Taylor, J B; Redmer, D A; Reynolds, L P; Vonnahme, K A
2010-11-01
Lambs born from feed-restricted or overfed ewes can be lighter at birth, whereas maternal Se supplementation can increase fetal size near term. We hypothesized that birth weight would be inversely related to feed efficiency and growth rates during postnatal development. To examine the effects of maternal dietary Se and nutrient restriction or excess on postnatal lamb growth, diet digestibility, and N retention, 82 ewe lambs (52.2 ± 0.8 kg) were allotted randomly to 1 of 6 treatments in a 2 × 3 factorial arrangement. Factors were dietary Se [adequate Se (9.5 μg/kg of BW; ASe) vs. high Se (Se-enriched yeast; 81.8 μg/kg of BW; HSe)] and maternal nutritional intake [60% (restricted, RES), 100% (control, CON), or 140% (high, HI) of NRC requirements]. Selenium treatments began at breeding. Nutritional treatments began on d 50 of gestation. Lambs were immediately removed from their dams at parturition, provided artificial colostrum, and fed milk replacer until weaning. After weaning, lambs were maintained using common management and on common diets until necropsy at 180 d. Male and female lambs from RES-fed ewes were lighter (P ≤ 0.03) at birth than lambs from CON-fed ewes, with lambs from HI-fed ewes being intermediate. Although maternal nutritional intake influenced (P < 0.06) BW gain before weaning on d 57, both maternal nutritional intake and sex of offspring influenced (P ≤ 0.09) BW gain from d 57 to 180. Although maternal nutritional intake did not influence (P ≥ 0.35) female lamb BW gain, male lambs from RES-fed ewes were lighter (P ≤ 0.09) than those from CON-fed ewes until d 162. By d 180, male lambs from RES- and HI-fed ewes were lighter (P ≤ 0.09) than those from CON-fed ewes. In a subset of lambs used in a feed efficiency study, namely, those born to ASe ewes, HI maternal nutritional intake decreased (P ≤ 0.09) ADG and G:F compared with lambs born to RES- and CON-fed ewes, which did not differ (P ≥ 0.60). Conversely, when lambs were born to HSe ewes, HI maternal nutritional intake increased (P ≤ 0.01) ADG and G:F compared with CON, with RES being intermediate. Moreover, lambs born to ASe-HI ewes had decreased (P < 0.01) ADG and G:F compared with lambs born to HSe-HI ewes. Furthermore, male lambs had a greater (P < 0.01) G:F than female lambs. Maternal diet did not affect (P ≥ 0.11) N retention in male lambs. These data indicate that maternal nutrition during gestation and sex of the offspring alter postnatal growth and efficiency of growth in offspring despite similar postnatal management.
Radio-frequency plasma transducer for use in harsh environments.
May, Andrew; Andarawis, Emad
2007-10-01
We describe a compact transducer used to generate and modulate low-intensity radio-frequency atmospheric pressure plasma (RF-APP) for high temperature gap measurement and generation of air-coupled ultrasound. The new transducer consists of a quarter-wave transmission line where the ground return path is a coaxial solenoid winding. The RF-APP is initiated at the open end of the transmission line and stabilized by passive negative feedback between the electrical impedance of the plasma and the energy stored in the solenoid. The electrical impedance of the plasma was measured at the lower-voltage source end of the transducer, eliminating the need to measure kilovolt-level voltages near the discharge. We describe the use of a 7 MHz RF-APP prototype as a harsh-environment clearance sensor to demonstrate the suitability of plasma discharges for a common nondestructive inspection application. Clearance measurements of 0-5 mm were performed on a rotating calibration target with a measurement precision of 0.1 mm and a 20 kHz sampling rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Faqi; Zeng, Deping; He, Min
2015-12-15
Resolution of high intensity focused ultrasound (HIFU) focusing is limited by the wave diffraction. We have developed a spherical cavity transducer with two open ends to improve the focusing precision without sacrificing the acoustic intensity (App Phys Lett 2013; 102: 204102). This work aims to theoretically and experimentally investigate the frequency dependence of the acoustic field generated from the spherical cavity transducer with two open ends. The device emits high intensity ultrasound at the frequency ranging from 420 to 470 kHz, and the acoustic field is measured by a fiber optic probe hydrophone. The measured results shows that the sphericalmore » cavity transducer provides high acoustic intensity for HIFU treatment only in its resonant modes, and a series of resonant frequencies can be choosen. Furthermore, a finite element model is developed to discuss the frequency dependence of the acoustic field. The numerical simulations coincide well with the measured results.« less
Cellular polypropylene polymer foam as air-coupled ultrasonic transducer materials.
Satyanarayan, L; Haberman, Michael R; Berthelot, Yves H
2010-10-01
Cellular polypropylene polymer foams, also known as ferroelectrets, are compelling candidates for air-coupled ultrasonic transducer materials because of their excellent acoustic impedance match to air and because they have a piezoelectric d(33) coefficient superior to that of PVDF. This study investigates the performance of ferroelectret transducers in the generation and reception of ultrasonic waves in air. As previous studies have noted, the piezoelectric coupling coefficients of these foams depend on the number, size, and distribution of charged voids in the microstructure. The present work studies the influence of these parameters both theoretically and experimentally. First, a three-dimensional model is employed to explain the variation of piezoelectric coupling coefficients, elastic stiffness, and dielectric permittivity as a function of void fraction based on void-scale physics and void geometry. Laser Doppler vibrometer (LDV) measurements of the effective d(33) coefficient of a specially fabricated prototype transmitting transducer are then shown which clearly indicate that the charged voids in the ferroelectret material are randomly distributed in the plane of the foam. The frequency-dependent dynamic d(33) coefficient is then reported from 50 to 500 kHz for different excitation voltages and shown to be largely insensitive to drive voltage. Lastly, two ferroelectret transducers are operated in transmit-receive mode and the received signal is shown to accurately represent the corresponding signal generated by the transmitting transducer as measured using LDV.
Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing.
Jang, Jihun; Chang, Jin Ho
2016-08-06
Beauty treatment for skin requires a high-intensity focused ultrasound (HIFU) transducer to generate coagulative necrosis in a small focal volume (e.g., 1 mm³) placed at a shallow depth (3-4.5 mm from the skin surface). For this, it is desirable to make the F-number as small as possible under the largest possible aperture in order to generate ultrasound energy high enough to induce tissue coagulation in such a small focal volume. However, satisfying both conditions at the same time is demanding. To meet the requirements, this paper, therefore, proposes a double-focusing technique, in which the aperture of an ultrasound transducer is spherically shaped for initial focusing and an acoustic lens is used to finally focus ultrasound on a target depth of treatment; it is possible to achieve the F-number of unity or less while keeping the aperture of a transducer as large as possible. In accordance with the proposed method, we designed and fabricated a 7-MHz double-focused ultrasound transducer. The experimental results demonstrated that the fabricated double-focused transducer had a focal length of 10.2 mm reduced from an initial focal length of 15.2 mm and, thus, the F-number changed from 1.52 to 1.02. Based on the results, we concluded that the proposed double-focusing method is suitable to decrease F-number while maintaining a large aperture size.
Location identification of closed crack based on Duffing oscillator transient transition
NASA Astrophysics Data System (ADS)
Liu, Xiaofeng; Bo, Lin; Liu, Yaolu; Zhao, Youxuan; Zhang, Jun; Deng, Mingxi; Hu, Ning
2018-02-01
The existence of a closed micro-crack in plates can be detected by using the nonlinear harmonic characteristics of the Lamb wave. However, its location identification is difficult. By considering the transient nonlinear Lamb under the noise interference, we proposed a location identification method for the closed crack based on the quantitative measurement of Duffing oscillator transient transfer in the phase space. The sliding short-time window was used to create a window truncation of to-be-detected signal. And then, the periodic extension processing for transient nonlinear Lamb wave was performed to ensure that the Duffing oscillator has adequate response time to reach a steady state. The transient autocorrelation method was used to reduce the occurrence of missed harmonic detection due to the random variable phase of nonlinear Lamb wave. Moreover, to overcome the deficiency in the quantitative analysis of Duffing system state by phase trajectory diagram and eliminate the misjudgment caused by harmonic frequency component contained in broadband noise, logic operation method of oscillator state transition function based on circular zone partition was adopted to establish the mapping relation between the oscillator transition state and the nonlinear harmonic time domain information. Final state transition discriminant function of Duffing oscillator was used as basis for identifying the reflected and transmitted harmonics from the crack. Chirplet time-frequency analysis was conducted to identify the mode of generated harmonics and determine the propagation speed. Through these steps, accurate position identification of the closed crack was achieved.
High spatial resolution imaging for structural health monitoring based on virtual time reversal
NASA Astrophysics Data System (ADS)
Cai, Jian; Shi, Lihua; Yuan, Shenfang; Shao, Zhixue
2011-05-01
Lamb waves are widely used in structural health monitoring (SHM) of plate-like structures. Due to the dispersion effect, Lamb wavepackets will be elongated and the resolution for damage identification will be strongly affected. This effect can be automatically compensated by the time reversal process (TRP). However, the time information of the compensated waves is also removed at the same time. To improve the spatial resolution of Lamb wave detection, virtual time reversal (VTR) is presented in this paper. In VTR, a changing-element excitation and reception mechanism (CERM) rather than the traditional fixed excitation and reception mechanism (FERM) is adopted for time information conservation. Furthermore, the complicated TRP procedure is replaced by simple signal operations which can make savings in the hardware cost for recording and generating the time-reversed Lamb waves. After the effects of VTR for dispersive damage scattered signals are theoretically analyzed, the realization of VTR involving the acquisition of the transfer functions of damage detecting paths under step pulse excitation is discussed. Then, a VTR-based imaging method is developed to improve the spatial resolution of the delay-and-sum imaging with a sparse piezoelectric (PZT) wafer array. Experimental validation indicates that the damage scattered wavepackets of A0 mode in an aluminum plate are partly recompressed and focalized with their time information preserved by VTR. Both the single damage and the dual adjacent damages in the plate can be clearly displayed with high spatial resolution by the proposed VTR-based imaging method.
Grigg, Jamin L; Wolfe, Lisa L; Fox, Karen A; Killion, Halcyon J; Jennings-Gaines, Jessica; Miller, Michael W; P Dreher, Brian
2017-07-01
We evaluated the use of vaginal implant transmitters (VITs) as a means of detecting, capturing, and radio collaring Rocky Mountain bighorn sheep ( Ovis canadensis canadensis) lambs to estimate survival and to facilitate carcass recovery to assess causes of mortality. We focused on one of several bighorn herds in Colorado, US, suffering from depressed recruitment that was not preceded by a classic all-age die-off. We captured, radio-collared, diagnosed pregnancy by ultrasound examination, and inserted VITs into 15 pregnant ewes from a herd residing near Granite, Colorado. We were subsequently able to collar a lamb from each of 13 VITs, and two additional lambs opportunistically from ewes without transmitters. As lambs died, we recovered and submitted carcasses for necropsy and laboratory assessment. All lambs captured and one additional lamb (carcass found opportunistically) were dead by about 130 d of age: 11 died of apparent pneumonia (all within 8-10 wk of age), one died from trauma after being kicked or trampled, one was killed by a mountain lion ( Puma concolor ), and three died of starvation likely caused by abandonment after capture. Pneumonic lambs had involvement of Mycoplasma ovipneumoniae and leukotoxigenic Bibersteinia trehalosi . The use of VITs and lamb collars enabled us to efficiently identify pneumonia as the predominant cause of depressed lamb recruitment in this herd; however, we urge care in neonatal lamb handling to minimize abandonment.
7 CFR 1280.211 - Prohibited activities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information... and agents of the lamb industry from engaging in: (a) Any action that would be a conflict of interest...
7 CFR 1280.216 - Procedure for obtaining a refund.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Expenses § 1280... collected applicant's assessment; (3) Number of head of lambs, weight of lambs, or its equivalent, on which...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.107 Feeder. Feeder means any person who acquires ownership of lambs and feeds such lambs in the U.S. until they reach slaughter...
7 CFR 1280.221 - Prohibition on use of funds.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Assessments... pursuant to this title shall not make false or misleading claims on behalf of lamb or lamb products or...
Slocum, M K; Halden, N F; Parkinson, J S
1987-01-01
The tar and tap loci of Escherichia coli encode methyl-accepting inner membrane proteins that mediate chemotactic responses to aspartate and maltose or to dipeptides. These genes lie adjacent to each other in the same orientation on the chromosome and have extensive sequence homology throughout the C-terminal portions of their coding regions. Many spontaneous deletions in the tar-tap region appear to be generated by recombination between these regions of homology, leading to gene fusions that produce hybrid transducer molecules in which the N terminus of Tar is joined to the C terminus of Tap. The properties of two such hybrids are described in this report. Although Tar and Tap molecules have homologous domain structures, these Tar-Tap hybrids exhibited defects in stimulus detection and flagellar signaling. Both hybrid transducers retained Tar receptor specificity, but had reduced detection sensitivity. This defect was correlated with the presence of the C-terminal methyl-accepting segment of Tap, which may have more methylation sites than its Tar counterpart, leading to elevated steady-state methylation levels in the hybrid molecules. One of the hybrids, which carried a more extensive segment from Tap, appeared to generate constitutive signals that locked the flagellar motors in a counterclockwise rotational mode. Changes in the methylation state of this transducer were ineffective in cancelling this aberrant signal. These findings implicate the conserved C-terminal domain of bacterial transducers in the generation or regulation of flagellar signals. Images PMID:3110130
Knights, Marlon; Ramgattie, Reeza; Siew, Narendra; Singh-Knights, Doolarie; Bourne, Gregory
2011-06-01
The efficacy of using a low cost system for delivering progesterone as part of an estrous synchronization protocol in sheep was evaluated. In experiment 1, Barbados Black Belly ewes (n=34) and ewe lambs (n=35; 37.5±0.9 kg) were assigned to be untreated, control animals (C), or to receive PGF(2α) on d0 (PG), or receive two injections of progesterone (200mg, i.m. each) on D -5 and on D -2.5, prior to PGF(2α), on D 0 (2PPG). Treatment with 2PPG increased the proportion of animals lambing to the first service (P<0.05), an effect that was greater in ewe lambs than ewes (treatment × parity; P<0.05). The interval from ram introduction to lambing and the mean lambing day was less (P=0.04) in the 2PPG-treated animals compared to control animals. In Experiment 2, lactating ewes from experiment 1 (n=61) 60-85 days postpartum were assigned within parity and number of lambs reared to remain nursing (S; n=29) or weaned (W; n=32) 3 weeks prior to treatment with the 2PPG protocol. There was no effect of treatment on the proportion of animals lambing to the first service or overall, interval from ram introduction to lambing and lambing interval. An 8-month lambing interval was observed in ewes in which estrus was synchronized regardless of physiological state. In conclusion, the two-progesterone injection synchronization protocol may be used as a practical low cost and efficient method of synchronizing estrus to reduce the lambing interval and maximize productivity in tropical breeds of sheep. Copyright © 2011 Elsevier B.V. All rights reserved.
Temperament and its heritability in Corriedale and Merino lambs.
Zambra, N; Gimeno, D; Blache, D; van Lier, E
2015-03-01
Temperament can be defined as the fearfulness and reactivity of an animal in response to humans and strange, novel or threatening environments. The productive performance of an animal is affected by its temperament, and selection of calm animals might improve their adaptation to the farming environment and handling, as well as improve productivity. The temperament was measured in lambs of two breeds of sheep in Uruguay. The effects of dam's age, type of birth, age of the lamb and contemporary group (CG; lambs belonging to the same year, flock, sex and rearing group) on the temperament of the lambs and the heritability of temperament were estimated with a Bayesian analysis using Gibbs sampling. Overall, 4962 Corriedale lambs and 2952 Merino lambs from 13 farms were tested. Temperament was measured using the isolation box test, isolating a lamb inside the box for 30 s, and recording the vibrations produced by its movements. The average temperament score (±s.e.m.) of the Corriedale lambs was 24.7 (±0.23) and that of the Merino was 36.8 (±0.45). Temperament was not associated with dam's age, type of birth or lamb's age. There were no relevant differences in the agitation score between lambs born in 2010 and 2011. The mean of the distribution of possible values of heritability (±s.d.) was 0.18 (±0.05) for the Corriedale and 0.31 (±0.06) for the Merino. The likelihood of heritability values to be greater than 0.15 exceeded 70% in the Corriedale and 90% in the Merino. The temperament of Merino and Corriedale sheep in Uruguay is moderately heritable. It is not related to dam's age, type of birth or age of the lambs; however, it is affected by some aspect of the CG.
Techniques for capturing bighorn sheep lambs
Smith, Joshua B.; Walsh, Daniel P.; Goldstein, Elise J.; Parsons, Zachary D.; Karsch, Rebekah C.; Stiver, Julie R.; Cain, James W.; Raedeke, Kenneth J.; Jenks, Jonathan A.
2014-01-01
Low lamb recruitment is a major challenge facing managers attempting to mitigate the decline of bighorn sheep (Ovis canadensis), and investigations into the underlying mechanisms are limited because of the inability to readily capture and monitor bighorn sheep lambs. We evaluated 4 capture techniques for bighorn sheep lambs: 1) hand-capture of lambs from radiocollared adult females fitted with vaginal implant transmitters (VITs), 2) hand-capture of lambs of intensively monitored radiocollared adult females, 3) helicopter net-gunning, and 4) hand-capture of lambs from helicopters. During 2010–2012, we successfully captured 90% of lambs from females that retained VITs to ≤1 day of parturition, although we noted differences in capture rates between an area of high road density in the Black Hills (92–100%) of South Dakota, USA, and less accessible areas of New Mexico (71%), USA. Retention of VITs was 78% with pre-partum expulsion the main cause of failure. We were less likely to capture lambs from females that expelled VITs ≥1 day of parturition (range = 80–83%) or females that were collared without VITs (range = 60–78%). We used helicopter net-gunning at several sites in 1999, 2001–2002, and 2011, and it proved a useful technique; however, at one site, attempts to capture lambs led to lamb predation by golden eagles (Aquila chrysaetos). We attempted helicopter hand-captures at one site in 1999, and they also were successful in certain circumstances and avoided risk of physical trauma from net-gunning; however, application was limited. In areas of low accessibility or if personnel lack the ability to monitor females and/or VITs for extended periods, helicopter capture may provide a viable option for lamb capture.
de Melo, Gleice Kelli Ayardes; Ítavo, Camila Celeste Brandão Ferreira; Monteiro, Kedma Leonora Silva; da Silva, Jonilson Araújo; da Silva, Pâmila Carolini Gonçalves; Ítavo, Luís Carlos Vinhas; Borges, Dyego Gonçalves Lino; de Almeida Borges, Fernando
2017-05-30
This study evaluated the effect of creep feeding a protein supplement on the susceptibility of suckling lambs to infection with gastrointestinal helminths. Male and female lambs were grazed on Brachiaria spp. pastures next to their mothers. Animals were allocated to one of two treatments: creep feeding (261g/d) and control (no supplementation). The trial period was the suckling of lambs during two years of study: May-October 2013 and March-July 2014. Supplementary creep feeding of lambs improved animal performance (P<0.05). Creep-fed lambs reached 18kg body weight in 64 d, but unsupplemented lambs required 77 d to reach the same weight. Lambs were susceptible to helminth infection during lactation; lambs in both treatments had high fecal egg counts (FECs), with means >1000 eggs per gram, as early as 45days of age, when the daily grazing time per animal increased. Creep feeding reduced the FECs of suckling lambs >60days of age in infections dominated by Haemonchus contortus. Totals of 20 and 48 anthelmintic treatments were administered to the supplemented and unsupplemented animals, respectively. The effect of this variable, however, was significant (P<0.05) only after 60days, when nine and 28 treatments had been administered to the supplemented and unsupplemented lambs, respectively. The number of strongyloid larvae recovered from the paddock did not differ significantly (P >0.05) between the two treatments, indicating similar challenges by infective larvae to both groups. The supplementation of lambs by creep feeding can thus be a strategy for the sustainable control of helminth infection, because it reduces the dependence on anthelmintic treatment. Copyright © 2017. Published by Elsevier B.V.
USDA-ARS?s Scientific Manuscript database
Our objective was to establish doses of orally-administered NaClO3 that reduced presence of generic Escherichia coli in intestines of ewes and neonatal lambs managed in a shed-lambing system. Neonatal lambs (n = 32; age = 7.1 ± 1.2 d; BW = 6.8 ± 1.0 kg) and yearling ewes (n = 44; BW = 74.8 ± 5.6 kg)...
Lamb and kid mortality in village flocks in the coastal savanna zone of Ghana.
Turkson, P K
2003-12-01
A cohort study was designed to observe and follow up mortality in lambs and kids in 88 flocks of sheep and goats under the traditional production system in five villages within the coastal savanna zone of Ghana over a 2-year period. The overall mortality rates for kids and lambs were 30.8% and 33.5%, respectively. Significantly higher proportions of kids (80.2%) and lambs (75.6%) up to 3 months of age died compared to kids and lambs from 4 to 12 months of age. The differences in mortality rates, either between male and female kids and lambs or between single-born and multiple-birth kids and lambs, were not significant. The odds ratio (OR) and relative risks (RR) for lambs and kids, on the basis of sex and birth types, were not significant; neither were the values obtained for attributable risk, attributable fraction, population attributable risk and population attributable fraction. The overall mortality rate on the basis of species of animal was not significant. At the village level, significant differences in the proportions of mortality on the basis of sex were seen in two villages. At Akotokyir, more male lambs (54.2%) died compared to females (27.6%), while at Apewosika more female lambs (42.2%) died compared to males (16.7%). The only significant difference in mortality proportions on the basis of birth type at the village level was seen at Apewosika, where more single-born kids died (52.8%) compared to kids born with sibling(s) (28.4%). The significant ORs for mortalities were 3.10 for male lambs at Akotokyir, 3.35 for female lambs at Apewosika and 2.82 for single-born kids at Apewosika. The corresponding RRs were equally significant. On the basis of species, significantly more lambs died at Akotokyir (44.2%) and Kwesimprah (44.7%) compared to kids. The implications of these findings are discussed.
Al Khewani, Talal; Momani Shaker, Mohamed; Al-Olofi, Samer
2014-12-01
A fattening experiment was carried out to analyze and evaluate the effect of ram lamb genotype on the growth, feed conversion (FC), and carcass value of Dhamari ram lambs, F1 crossbreds of Dhamari × Tehami (F1 DhT), and Tehami ram lambs. Genotype of the ram lambs including the experiment (n = 30) had high significant effect on total weight gain (TWG), average daily gain (ADG), and FC (P < 0.01-0.001). Genotype of the lamb had significant effect on hot and cold dressing percentage (P < 0.001). Also, genotype of the lamb had significant effect on the highest leg percentage (P < 0.001). Furthermore, genotype of the ram lambs had significant effect on musculus longissimus dorsi (MLD) area (P < 0.001). Genotype of the ram lamb had significant effect on TWG, ADG, and FC (P < 0.001). The results of moisture percentage, crude protein percentage, and ash percentage of muscle samples were significantly influenced by ram lamb's genotype (P < 0.001). Fasting live weight and other carcass measurements (hot carcass weight, leg weight, loin weight, shoulder weight, first quality cuts weight) have a positive and highest correlations (P < 0.001). The positive and the highest correlations were found between fasting live weight and hot carcass weight, first quality parts weight. In addition, the positive and the highest correlations were found between hot carcass weight and first quality cuts weight. In general, the results of this study documented that F1 DhT was better than Tehami ram lambs in ADG, TWG, and FC. Additionally, the results show that the feed conversion was in F1 DhT crossbreds ram lambs better than pure Dhamari and Tehami ram lambs, mainly in the carcass indicators.
Enhancing nutritiousness of lamb meat and preventing selenium deficiency.
USDA-ARS?s Scientific Manuscript database
Lamb meat is a naturally flavorful and nutritious product. Our research indicates that feeding a specific wheat-milling coproduct will enhance the nutritiousness of lamb, potentially add monetary value to lamb, and prevent Se deficiency. Selenium is an essential micromineral, and Se supplementation ...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-24
...] RIN 0581-AD29 Mandatory Country of Origin Labeling of Beef, Pork, Lamb, Chicken, Goat Meat, Wild and... (including veal), lamb, chicken, goat, and pork; ground beef, ground lamb, ground chicken, ground goat, and...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Assessments § 1280.218 Exporter. Each person exporting live lambs shall remit to the Board an assessment on such lambs at the time of export at the rate...
The impact of genetics on retail meat value in Australian lamb.
Anderson, F; Pethick, D W; Gardner, G E
2016-07-01
Lean (muscle), fat, and bone composition of 1554 lamb carcasses from Maternal, Merino and Terminal sired lambs was measured using computed tomography scanning. Lamb sires were diverse in their range of Australian Sheep Breeding Values for post weaning c-site eye muscle depth (PEMD) and fat depth (PFAT), and post weaning weight (PWWT). Lean value, representing predicted lean weight multiplied by retail value, was determined for lambs at the same carcass weight or the same age. At the same carcass weight, lean value was increased the most by reducing sire PFAT, followed by increasing PEMD and PWWT. However for lambs of the same age, increasing sire PWWT increased lean value the most. Terminal sired lambs, on average, had greater lean value irrespective of whether comparisons were made at the same age or weight. Lean value was greater in Merino compared to Maternal sired lambs at equal carcass weight, however the reverse was true when comparisons were made at the same age. Copyright © 2016 Elsevier Ltd. All rights reserved.
Understanding consumers' perception of lamb meat using free word association.
de Andrade, Juliana Cunha; de Aguiar Sobral, Louise; Ares, Gastón; Deliza, Rosires
2016-07-01
The aims of the present study were to gather information about Brazilian consumers' perception of lamb meat and to study whether the perception is affected by the consumption frequency of this type of meat. A total of 1025 Brazilian consumers completed word association task with lamb meat. The elicited words were analyzed using inductive coding. Participants' associations with lamb meat were mainly related to sensory characteristics and hedonic attitudes and feelings, indicating that they might be the main motivations for consuming this product. Participants strongly associated lamb meat with special consumption occasions, which suggests that lack of perceived appropriateness for everyday consumption situations might be a barrier for increasing lamb meat consumption. Conceptualization of lamb meat was strongly affected by frequency of consumption of this product. Results from the present work provide a comprehensive insight on Brazilian consumers' perception of lamb meat, which can be used to develop strategies to increase its consumption and improve profitability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T
2009-10-01
State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.
Acoustic levitation of a large solid sphere
NASA Astrophysics Data System (ADS)
Andrade, Marco A. B.; Bernassau, Anne L.; Adamowski, Julio C.
2016-07-01
We demonstrate that acoustic levitation can levitate spherical objects much larger than the acoustic wavelength in air. The acoustic levitation of an expanded polystyrene sphere of 50 mm in diameter, corresponding to 3.6 times the wavelength, is achieved by using three 25 kHz ultrasonic transducers arranged in a tripod fashion. In this configuration, a standing wave is created between the transducers and the sphere. The axial acoustic radiation force generated by each transducer on the sphere was modeled numerically as a function of the distance between the sphere and the transducer. The theoretical acoustic radiation force was verified experimentally in a setup consisting of an electronic scale and an ultrasonic transducer mounted on a motorized linear stage. The comparison between the numerical and experimental acoustic radiation forces presents a good agreement.
Optical micromachined ultrasound transducers (OMUT)--a new approach for high-frequency transducers.
Tadayon, Mohammad Amin; Ashkenazi, Shai
2013-09-01
The sensitivity and reliability of piezoelectric ultrasound transducers severely degrade in applications requiring high frequency and small element size. Alternative technologies such as capacitive micromachined ultrasound transducers (CMUT) and optical sensing and generation of ultrasound have been proposed and studied for several decades. In this paper, we present a new type of device based on optical micromachined ultrasound transducer (OMUT) technology. OMUTs rely on microfabrication techniques to construct micrometerscale air cavities capped by an elastic membrane. A modified photoresist bonding process has been developed to facilitate the fabrication of these devices. We will describe the design, fabrication, and testing of prototype OMUT devices which implement a receive-only function. Future design modifications are proposed for incorporating complete transmit¿receive functionality in a single element.
Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis.
Kim, Jinwook; Lindsey, Brooks D; Chang, Wei-Yi; Dai, Xuming; Stavas, Joseph M; Dayton, Paul A; Jiang, Xiaoning
2017-06-14
Effective removal or dissolution of large blood clots remains a challenge in clinical treatment of acute thrombo-occlusive diseases. Here we report the development of an intravascular microbubble-mediated sonothrombolysis device for improving thrombolytic rate and thus minimizing the required dose of thrombolytic drugs. We hypothesize that a sub-megahertz, forward-looking ultrasound transducer with an integrated microbubble injection tube is more advantageous for efficient thrombolysis by enhancing cavitation-induced microstreaming than the conventional high-frequency, side-looking, catheter-mounted transducers. We developed custom miniaturized transducers and demonstrated that these transducers are able to generate sufficient pressure to induce cavitation of lipid-shelled microbubble contrast agents. Our technology demonstrates a thrombolysis rate of 0.7 ± 0.15 percent mass loss/min in vitro without any use of thrombolytic drugs.
Impact of rotational grazing on management of gastrointestinal nematodes in weaned lambs.
Burke, J M; Miller, J E; Terrill, T H
2009-07-07
Gastrointestinal nematode (GIN) control for 'natural' or organic lamb production is needed, especially where Haemonchus contortus is prevalent. The objective was to determine the impact of rotational grazing on GIN infection of weaned lambs. In year 1, naturally infected Katahdin lambs (120 days of age) were randomly assigned to graze (1) continuous bermudagrass (CB; n=14), (2) rotational bermudagrass moved every 3.5 days and returned to original plot 35 days later for three rotations (RB; n=14), or (3) rotational bermudagrass rotated when forage height fell below 10 cm (RBH; n=7) where first day of grazing=Day 0. In late summer, all lambs were supplemented with 500 g corn/SBM because of poor condition. The following year, similar animals were used and included the CB (n=18) and the RB (n=36) groups only. In both years, fecal egg counts (FECs) and blood packed cell volume (PCV) were determined every 7-14 days and body weight every 28 days. Individuals were dewormed with 0.5 g copper oxide wire particles (COWP) when FAMACHA score increased to 3 or more. Between 0 and 3 deworming treatments per lamb were necessary and there tended to be fewer RB than CB lambs dewormed by Day 84 for both years combined (P<0.001). Worm free tracer lambs were introduced to CB (n=6) and RB (n=8) plots following the last rotation during the first year to determine worm burdens after 20 days of grazing. Abomasal worm burden tended to be greater in RB than CB or RBH tracer lambs (P<0.10), but intestinal worm numbers were similar. Differences may be due to differences in grazing patterns among groups. Body weight gains were similar between CB and RB groups. Economic value between the CB and RB lambs was similar based on number of lambs that could have been marketed as organic. For both years, lambs relied exclusively on COWP for GIN control with the exception of one lamb. In summary, while there was a reduced incidence of deworming in the RB compared with the CB group of lambs, estimated economic value of these systems was similar.
The Tea-Carbon Dioxide Laser as a Means of Generating Ultrasound in Solids
NASA Astrophysics Data System (ADS)
Taylor, Gregory Stuart
1990-01-01
Available from UMI in association with The British Library. Requires signed TDF. The aim of this thesis is to characterise the interaction between pulsed, high power, 10.6 mu m radiation and solids. The work is considered both in the general context of laser generation of ultrasound and specifically to gain a deeper understanding of the interaction between a laser supported plasma and a solid. The predominant experimental tools used are the homodyne Michelson interferometer and a range of electromagnetic acoustic transducers. To complement the ultrasonic data, various plasma inspection techniques, such as high speed, streak camera photography and reflection photometry, have been used to correlate the plasma properties with those of the ultrasonic transients. The work involving the characterisation of a laser supported plasma with a solid, which is based on previous experimental and theoretical analysis, gives an increased understanding of the plasma's ultrasonic generation mechanism. The ability to record the entire plasma-sample interaction, time history yields information of the internal dynamics of the plasma growth and shock wave generation. The interaction of the radiation with a solid is characterised in both the plasma breakdown and non-breakdown regimes by a wide ultrasonic source. The variation in source diameter enables the transition from a point to a near planar ultrasonic source to be studied. The resultant ultrasonic modifications are examined in terms of the wave structure and the directivity pattern. The wave structure is analysed in terms of existing wide source, bulk wave theories and extended to consider the effects on surface and Lamb waves. The directivity patterns of the longitudinal and shear waves are analysed in terms of top-hat and non -uniform source profiles, giving additional information into the radiation-solid interaction. The wide, one dimensional source analysis is continued to a two dimensional, extended ultrasonic source, generated on non-metals by the optical penetration of radiation within the target. The generation of ultrasound in both metals and non-metals, using the CO_2 laser, is shown to be an efficient process and may be employed almost totally non-destructively. Such a laser may therefore be used effectively on a greatly enhanced range of materials than those tested to-date via laser generation, resulting in the increased suitability of the laser technique within the field of Non Destructive Testing.
Propagation of time-reversed Lamb waves in bovine cortical bone in vitro.
Lee, Kang Il; Yoon, Suk Wang
2015-01-01
The present study aims to investigate the propagation of time-reversed Lamb waves in bovine cortical bone in vitro. The time-reversed Lamb waves were successfully launched at 200 kHz in 18 bovine tibiae through a time reversal process of Lamb waves. The group velocities of the time-reversed Lamb waves in the bovine tibiae were measured using the axial transmission technique. They showed a significant correlation with the cortical thickness and tended to follow the theoretical group velocity of the lowest order antisymmetrical Lamb wave fairly well, consistent with the behavior of the slow guided wave in long cortical bones.
Aguayo-Ulloa, L A; Pascual-Alonso, M; Olleta, J L; Sañudo, C; Miranda-de la Lama, G C; María, G A
2015-07-01
We analysed the effect of a modified pen using a wooden screen with flaps and cereal straw as forage and bedding, on behaviour, stress response, performance and meat quality variables of lambs housed in feedlots. Sixty male lambs were placed in enriched (ESF) or conventional (CO) pens (3 pens/treatment, 10 lambs/pen). The CO environment was barren. The ESF lambs showed a great preference for the provided items, which encouraged more natural and richer behaviour, reducing stereotypies and lamb aggressions, and increasing affiliations (P ≤ 0.05), which improves group cohesion. However, ESF lambs also developed a more natural coping style to the handling, evidenced by the higher cortisol levels (65.4 vs. 43.8 nmol/L) and a higher eye temperature as response to the reactivity test (38.1 vs. 37.8 °C). The ESF lambs had a higher (P ≤ 0.05) slaughter weight (27.2 vs. 26.3 kg), conformation score (7.38 vs. 6.07) and pH 24 (5.63 vs. 5.56) but lower cooking losses (12.9 vs. 14.9%) than CO lambs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mutagenicity of basic fractions derived from lamb and beef cooked by common household methods.
Barrington, P J; Baker, R S; Truswell, A S; Bonin, A M; Ryan, A J; Paulin, A P
1990-03-01
Mutagen production was examined in lamb and beef in relation to certain common household cooking methods. Mutagenicity was assessed, after extraction of the basic fraction of cooked meat samples, using Salmonella typhimurium strain TA1538 with added rat-liver S-9 homogenate. Little or no mutagenicity was found in barbecued lamb chops, in microwave-cooked lamb chops, sirloin steak, leg of lamb, or rolled beef loaf, in roasted leg of lamb or rolled beef loaf, in stewed blade steak or in boiled chuck steak. However, the basic fraction from well-done, edible fried or grilled meat contained mutagenic activity equivalent to approximately 30,000 TA1538 revertants/100 g cooked meat. It was found tht the mutagenic activity of grilled lamb chops, sirloin and rump steaks was directly related to the average surface temperatures attained during cooking. Use of butter as a frying medium was particularly associated with higher mutagenicity in meat samples. Fried meats (rump and fillet steaks) generally yielded higher mutagenic activity than did grilled meats (rump steak, lamb chops) at comparable temperatures of the cooking medium. Using similar cooking procedures, lamb did not differ markedly from beef in mutagenic activity.
Infrared thermal imaging as a method to evaluate heat loss in newborn lambs.
Labeur, L; Villiers, G; Small, A H; Hinch, G N; Schmoelzl, S
2017-12-01
Thermal imaging technology has been identified as a potential method for non-invasive study of thermogenesis in the neonatal lamb. In comparison to measurement of the core body temperature, infrared thermography may observe thermal loss and thermogenesis linked to subcutaneous brown fat depots. This study aimed to identify a suitable method to measure heat loss in the neonatal lamb under a cold challenge. During late pregnancy (day 125), ewes were subjected to either shearing (n=15) or mock handling (sham-shorn for 2min mimicking the shearing movements) (n=15). Previous studies have shown an increase in brown adipose tissue deposition in lambs born to ewes shorn during pregnancy and we hypothesized that the shearing treatment would impact thermoregulatory capacities in newborn lambs. Lambs born to control ewes (n=14; CONTROL) and shorn ewes (n=13; SHORN) were subjected to a cold challenge of 1h duration at 4h after birth. During the cold challenge, thermography images were taken every 10min, from above, at a fixed distance from the dorsal midline. On each image, four fixed-size areas were identified (shoulder, mid loin, hips and rump) and the average and maximum temperatures of each recorded. In all lambs, body surface temperature decreased over time. Overall the SHORN lambs appeared to maintain body surface temperature better than CONTROL lambs, while CONTROL lambs appeared to have higher core temperature. At 30min post cold challenge SHORN lambs tended to have higher body surface temperatures than lambs (P=0.0474). Both average and maximum temperatures were highest at the hips. Average temperature was lowest at the shoulder (P<0.05), while maximum temperatures were lowest at both shoulder and rump (P<0.005). These results indicate that lambs born to shorn ewes maintained their radiated body surface temperature better than CONTROL lambs. In conjunction with core temperature changes under cold challenge, this insight will allow us to understand whether increased body surface temperature contributes to increased overall heat loss or whether increased body surface temperature is indeed a mechanism contributing to maintenance of core body temperature under cold challenge conditions. This study has confirmed the utility of infrared thermography images to capture and identify different levels of thermoregulatory capacity in newborn lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Laser-based ultrasonics by dual-probe interferometer detection and narrow-band ultrasound generation
NASA Astrophysics Data System (ADS)
Huang, Jin
1993-01-01
Despite the advantages of laser-based ultrasonic (LBU) systems, the overall sensitivity of LBU systems needs to be improved for practical applications. Progress is reported to achieve better LBU detection accuracy and sensitivity for applications with surface waves and Lamb waves. A novel dual-probe laser interferometer has been developed to measure the same signal at two points. The dual-probe interferometer is a modification of a conventional single-probe interferometer in that the reference beam is guided to a second detecting point on the specimen surface to form a differential measurement mode, which measure the difference of the displacements at the two points. This dual-probe interferometer is particularly useful for accurate measurements of the speed and attenuation of surface waves and Lamb waves. The dual-probe interferometer has been applied to obtain accurate measurements of the surface wave speed and attenuation on surfaces of increasing surface roughness. It has also been demonstrated that with an appropriate signal processing method, namely, the power cepstrum method, the dual-probe interferometer is applicable to measure the local surface wave speed even when the probe separation is so small that the two waveforms in the interferometer output signal overlap in the time domain. Narrow-band signal generation and detection improve the sensitivity of LBU systems. It is proposed to use a diffraction grating to form an array of illuminating strips which form a source of narrowband surface and Lamb waves. The line-array of thermoelastic sources generates narrow-band signals whose frequency and bandwidth can be easily controlled. The optimum line-array parameters, such as width, spacing and the number of lines in the array have been derived theoretically and verified experimentally. Narrow-band signal generation with optimum parameters has been demonstrated. The enhanced LBU system with dual-probe detection and narrowband signal generation has been successfully applied to the detection of cracks emanating from rivet holes in aircraft fuselage panel samples. A compact fiber-optic dual-probe interferometer has also been developed and applied to the above mentioned problem of crack detection. Results agree well with those obtained with a bulk LBU system.
Sohi, R; Trompf, J; Marriott, H; Bervan, A; Godoy, B I; Weerasinghe, M; Desai, A; Jois, M
2017-11-01
The objectives of this study were to validate the application of Bluetooth technology to determine maternal pedigree and to determine ewe-lamb spatial relationships in extensive farming systems. A total of 35 first-cross Merino ewes (Merino × Border Leicester and East Friesian) and 23 of their lambs aged 1 to 3 wk were fitted with activity monitors equipped with Bluetooth (BT) technology (ActiGraph wGT3X-BT) by means of halters and collars, respectively. The BT devices on lambs were programmed to receive wireless signals once every minute from nearby BT units on ewes, which were programmed as beacons sending BT signals 4 times every second. Ewes and lambs fitted with sensors were dispatched into the paddocks, and after 10 d, the sensor units were retrieved and the BT signals received by lambs were downloaded using the ActiGraph software. The maternal pedigree of the lambs was determined as the ewe from which the lamb received the most BT signals. The distance between the lamb receiving the signal and the ewe sending the signal was estimated from the strength of BT signal received. The pedigree determined by BT was compared with the pedigree determined by DNA profiling and verification. The results showed that the accuracy of maternal pedigree determined by BT signals reached 100% within the first 15 min of returning animals to pasture of ewes and lambs fitted with sensors. Maternal signals (counts/d) received by 1-, 2-, and 3-wk-old lambs were 617 ± 102, 603 ± 54, and 498 ± 36, respectively, and the corresponding nonmaternal signals received were 140 ± 27, 106 ± 30, and 155 ± 39, respectively. Maternal signals received during the dark period were significantly higher than the maternal signals received during the light period ( < 0.05). Maternal signals received during the light period by 3-wk-old lambs were significantly lower when compared with those received by 1- and 2-wk-old lambs. Over 90% of the BT signals received from within 2 m of the lamb were from its mother. The maternal BT signals expressed as a portion of total BT signals decreased with increasing distance from the lamb. The results show that BT wireless networking is a fast and reliable method for the determination of maternal pedigree of lambs in extensive farming systems. In addition, wireless BT technology is also useful in determining mother-offspring spatial relationships.
Villalba, J J; Spackman, C; Goff, B M; Klotz, J L; Griggs, T; MacAdam, J W
2016-02-01
It was hypothesized that a tannin-rich legume such as sainfoin attenuates the negative postingestive effects of ergot alkaloids in tall fescue. Thirty-two 4-mo-old lambs were individually penned and randomly assigned to a 2 × 2 factorial arrangement with 2 legume species, sainfoin (SAN; 2.9% condensed tannins) or cicer milkvetch (CIC; without tannins) and a mixed ration containing tall fescue seed (50:30:20 seed:beet pulp:alfalfa) with 2 levels of endophyte infection (endophyte-infected tall fescue seed [E+; 3,150 ug/L ergovaline] or endophyte-free tall fescue seed [E-]). For a 10-d baseline period, half of the lambs were fed SAN and half were fed CIC and all lambs had ad libitum amounts of E-. In an ensuing 10-d experimental period, the protocol was the same except half of the lambs fed SAN or CIC received E+ instead of E-. Subsequently, all lambs could choose between their respective legume and seed-containing ration and between E+ and E-. Finally, an in vitro radial diffusion assay was conducted to determine whether tannins isolated from SAN would bind to alkaloids isolated from E+. All groups consumed similar amounts of E- during baseline period ( > 0.10), but lambs ate more E- than E+ during the experimental period ( < 0.05) and lambs offered SAN ate more E+ than lambs offered CIC ( < 0.05). Groups fed E- during the baseline and experimental periods had similar rectal temperatures ( > 0.10), but lambs fed E+ had lower rectal temperatures per gram of feed ingested when supplemented with SAN than with CIC ( < 0.05). Lambs fed E+ had greater concentrations of hemoglobin and more red blood cells than lambs fed E- ( < 0.05), but plasmatic concentrations of cortisol and prolactin did not differ among treatments ( > 0.10). All lambs preferred their treatment ration over their treatment legume, but lambs in the SAN and E+ treatment ate more legume + ration than lambs in the CIC and E+ (CIC-E+; < 0.05) treatment. All lambs preferred E- over E+, but lambs in the CIC-E+ treatment ate the least amount of E+ ( < 0.05). Binding of isolated SAN tannins to protein was reduced by the E+ isolate ( < 0.05), suggesting a tannin-alkaloid complexation but only from tannins extracted from SAN fed early in the experimental period. In summary, SAN supplementation increased intake of and preference for E+ and reduced rectal temperatures relative to CIC supplementation. Our results suggest that these effects were mediated by the condensed tannins in SAN through alkaloid inactivation, an interaction that declined with plant maturity.
Whitney, T R; Lupton, C J; Muir, J P; Adams, R P; Stewart, W C
2014-03-01
Effects of using ground redberry juniper and dried distillers grains with solubles (DDGS) in Rambouillet lamb (n = 45) feedlot diets on growth, blood serum, fecal, and wool characteristics were evaluated. In a randomized design study with 2 feeding periods (Period 1 = 64% concentrate diet, 35 d; Period 2 = 85% concentrate diet, 56 d), lambs were individually fed 5 isonitrogenous diets: a control diet (CNTL) that contained oat hay but not DDGS or juniper or DDGS-based diets in which 0 (0JUN), 33 (33JUN), 66 (66JUN), or 100% (100JUN) of the oat hay was replaced by juniper. During Period 1, lambs fed CNTL had greater (P < 0.05) DMI and ADG and tended to have greater (P < 0.10) G:F than lambs fed 0JUN or lambs fed DDGS-based diets. Lamb DMI, ADG, and G:F quadratically increased (P < 0.008) as juniper increased in the DDGS-based diets. During Period 2, lambs fed CNTL had greater (P < 0.05) DMI than lambs fed 0JUN or lambs fed DDGS-based diets, but ADG was similar (P > 0.41). Compared to 0JUN, lambs fed CNTL had similar (P = 0.12) G:F and tended to have less G:F (P = 0.07) than lambs fed DDGS-based diets. Among lambs fed DDGS-based diets, DMI was similar (P > 0.19), ADG increased linearly (P = 0.03), and G:F tended to decrease quadratically (P = 0.06) as juniper increased in the diet. Serum IGF-1, serum urea N (SUN), and fecal N were greater (P < 0.05) and serum Ca and P and fecal P were similar (P > 0.13) for lambs fed CNTL vs. lambs fed DDGS-based diets (CNTL). Within lambs fed DDGS-based diets, SUN increased quadratically (P = 0.01) and fecal N increased linearly (P = 0.004), which can partially be attributed to increased dietary urea and condensed tannin intake. Most wool characteristics were not affected, but wool growth per kilogram of BW decreased quadratically (P = 0.04) as percentage of juniper increased in the DDGS-based diets. When evaluating the entire 91-d feeding trial, results indicated that replacing all of the ground oat hay with ground juniper leaves and stems in lamb growing and finishing diets is not detrimental to animal performance and that DDGS-based diets can reduce total feedlot costs, as compared to sorghum grain and cottonseed meal-based diets. However, compared to using juniper or oat hay as the sole roughage source, using both during the growing period (Period 1) enhanced growth performance and further reduced total feedlot costs.
Noncontact measurement of guided ultrasonic wave scattering for fatigue crack characterization
NASA Astrophysics Data System (ADS)
Fromme, P.
2013-04-01
Fatigue cracks can develop in aerospace structures at locations of stress concentration such as fasteners. For the safe operation of the aircraft fatigue cracks need to be detected before reaching a critical length. Guided ultrasonic waves offer an efficient method for the detection and characterization of fatigue cracks in large aerospace structures. Noncontact excitation of guided waves was achieved using electromagnetic acoustic transducers (EMAT). The transducers were developed for the specific excitation of the A0 Lamb mode. Based on the induced eddy currents in the plate a simple theoretical model was developed and reasonably good agreement with the measurements was achieved. However, the detection sensitivity for fatigue cracks depends on the location and orientation of the crack relative to the measurement locations. Crack-like defects have a directionality pattern of the scattered field depending on the angle of the incident wave relative to the defect orientation and on the ratio of the characteristic defect size to wavelength. The detailed angular dependency of the guided wave field scattered at crack-like defects in plate structures has been measured using a noncontact laser interferometer. Good agreement with 3D Finite Element simulation predictions was achieved for machined part-through and through-thickness notches. The amplitude of the scattered wave was quantified for a variation of angle of the incident wave relative to the defect orientation and the defect depth. These results provide the basis for the defect characterization in aerospace structures using guided wave sensors.
Dever, M L; Kahn, L P
2015-04-30
The aim for this experiment was to look for evidence of milk transfer of anthelmintic actives from ewes to their suckling lambs by reference to lambs' faecal worm egg count (WEC). The hypothesis was that WEC will decline in lambs suckling ewes treated with anthelmintics known to be lipophilic. One group of lactating Border Leicester×Merino ewes were treated (TX) with a combination of short (2.5mg/kg monepantel) and long-acting (1mg/kg moxidectin long-acting injection and a sustained release of 4.62g albendazole over 100 days) anthelmintics to remove gastrointestinal nematode (GIN) burden on day 0. The other group of lactating ewes (UTX) and all lambs (White Suffolk sires) were not treated. Ewes and lambs grazed as a single group and were exposed to GIN (predominately Haemonchus contortus) infection from pasture. Measurements were taken on days 0 and 7. WEC of lambs suckling UTX ewes increased from 6441 to 10,341 eggs per gram (epg) between days 0 and 7, while there was a 51% reduction in WEC for lambs suckling TX ewes. Packed cell volume (PCV) was significantly higher for lambs suckling TX ewes on day 7 compared to lambs suckling UTX ewes (28.5% vs. 24.9%, p=0.039). These results suggest that lambs suckling ewes treated with lipophilic anthelmintics received a sub-therapeutic dose via milk which would increase selection within the GIN (H. contortus) population for anthelmintic resistance. Copyright © 2015 Elsevier B.V. All rights reserved.
Sericea lespdeza as an aid in the control of Emeria spp. in lambs.
Burke, J M; Miller, J E; Terrill, T H; Orlik, S T; Acharya, M; Garza, J J; Mosjidis, J A
2013-03-31
The objective was to examine the effects of feeding sericea lespedeza leaf meal (SL) on control of coccidiosis in lambs. In Exp. 1, naturally infected lambs (n=76) were weaned (102.7±1.4 d of age) in May (spring) and randomly assigned in a 2×2 factorial design to receive 2% of BW/d of alfalfa pellets (control) or SL with or without amprolium added to drinking water (n=38/level or 19/treatment). Fecal oocyst counts (FOC), egg counts (FEC), and fecal score (1=solid pellets; 5=slurry) were determined every 7d between weaning and 21 d post-weaning. In Exp. 2, twin rearing ewes were randomly assigned to two groups, and their naturally infected lambs were fed a control creep supplement (16% CP; n=40) or SL pellets (14% CP; n=32) 30 d before weaning. Intake of SL was initially low (100g/lamb daily) and increased to 454 g/lamb daily after weaning. Lambs were weaned at 103.6±0.9 d of age and moved to semi-confinement. The FEC, FOC, packed cell volume (PCV), fecal score, and dag score (soiling around rear of lamb; 1=no soiling; 5=heavy soiling) were determined at d -14, 0 (weaning), 7, 14, and 21. In Exp. 3, lambs were randomly assigned to a control or SL diet (n=12/diet) fed at 1.4 kg/d for 22d and inoculated with 50,000 sporulated oocysts on d 8, 11, and 13. The FEC, FOC, and fecal score were determined every 2 to 3d between d 1 and 29 (d 0=first day of dietary treatment). Data on all experiments were analyzed using mixed models. The FOC and FEC data were log transformed. Chi squared analysis was used to determine differences in incidence of treatment (sulfadimethoxine) for coccidiosis in Exp. 1 and 2. In Exp. 1, FOC and FEC were similar between dietary groups, and FOC declined more rapidly in amprolium treated lambs following weaning (P<0.001). Fecal score was higher in the control compared with the SL fed lambs (P=0.05), suggesting more signs of coccidiosis in control lambs. In Exp. 2, FOC was similar initially but was reduced in SL fed lambs by weaning and remained lower thereafter (P=0.004). Dag (P=0.01) and fecal (P=0.001) scores were similar before weaning, but lower in SL fed lambs by weaning and remained lower thereafter. No SL lambs required treatment for coccidiosis, whereas 33% of control lambs required treatment (P<0.001). Fecal egg counts were similar before weaning but were reduced in SL compared with control fed lambs after weaning (P<0.001). In Exp. 3, FOC (P<0.001) and FEC (P<0.001) were reduced in SL compared with control fed lambs. Sericea lespedeza was effective in the prevention and control of coccidiosis as well as in reducing GIN infection. Use of SL could reduce lamb loss post-weaning, reduce the need to treat for coccidiosis, and create a significant economic benefit to livestock producers. Published by Elsevier B.V.
7 CFR 4279.175 - Domestic lamb industry adjustment assistance program set aside.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 15 2010-01-01 2010-01-01 false Domestic lamb industry adjustment assistance program... GUARANTEED LOANMAKING Business and Industry Loans § 4279.175 Domestic lamb industry adjustment assistance... National Office to fund loans to lamb processors for real estate purchases and improvements; working...
21 CFR 880.5640 - Lamb feeding nipple.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lamb feeding nipple. 880.5640 Section 880.5640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5640 Lamb feeding nipple. (a) Identification. A lamb feeding nipple is a device intended for...
7 CFR 784.5 - Payment eligibility.
Code of Federal Regulations, 2010 CFR
2010-01-01
... lambs in the herd for at least one complete, normal offspring lambing cycle, the end of which shall... maintain the lambs for that period in accord with that certification. The “offspring” lambing cycle refers... must be engaged in the business of producing and marketing agricultural products at the time of filing...
Lashley, Vd; Roe, Wd; Kenyon, Pr; Thompson, Kg
2014-05-01
To compare the vascular and neuronal changes in the central nervous system (CNS) of lambs that died in the first 3 days after birth, from various causes, with control lambs subject to euthanasia. Dead lambs (n=65) were collected daily during the period 07 September 2010 to 26 September 2010 from a flock of 200 twin-lamb-bearing ewes. Age-matched lambs from the same flock were subject to euthanasia as a control group (n=39). Necropsies were conducted on all study lambs. The cause of death in lambs found dead was categorised as starvation-mismothering-exposure complex (SME), dystocia, or other, based on gross necropsy findings. Deaths were categorised as SME in lambs with necropsy lesions of pericardial, perirenal and mesenteric fat catabolism, an empty gastrointestinal tract and completely inflated lungs. Dystocia was diagnosed by the presence of a swollen tongue, injected sclera and subcutaneous oedema and haemorrhage around the head and neck or hind limbs. Deaths were categorised as other if an obvious cause of death could not be ascertained and if evidence of infection was identified. The CNS of each lamb necropsied was assessed grossly for haemorrhage, and using histopathology to determine vascular and neuronal changes. Immunohistochemistry was performed on selected cases (n=36) to confirm neuronal death. Of the 65 lambs found dead, 16 (25%) had evidence of cerebral and spinal meningeal haemorrhage, whereas of the 39 clinically normal control lambs, all displayed gross evidence of cerebral and spinal meningeal haemorrhage. There was no evidence of parenchymal vacuolation, neuronal vacuolation or ischaemic neurons in any of the lamb brain sections including those that died with evidence of dystocia. There was no difference, within the regions examined, in mean vascular score between lambs categorised by cause of death (p>0.05). The overall mean vascular score for the brain stem was greater than the mid brain (p=0.02) and the cortex (p=0.005) but did not differ from either the spinal cord or cerebellum (p>0.3). The vascular score for the spinal cord was greater than the mid brain (p=0.01) and cortex (p=0.003). Lambs that died of dystocia had less immunoreactivity for microtubule associated protein 2 (MAP2) in the hilus/CA4 region of the hippocampus (p=0.02) and dentate gyrus of the hippocampus (p=0.006) than those that were subject to euthanasia. Neither gross nor histological vascular changes in the CNS could be used to distinguish newborn lambs that had been subject to euthanasia from those that died with evidence of SME or dystocia, so meningeal haemorrhages in or on the brain and spinal cord of lambs that die in the neonatal period cannot be used to support a diagnosis of birth injury or dystocia. The CA4 region and the dentate gyrus of the hippocampus are useful regions for detecting hypoxic/ischaemic injury in lambs with evidence of dystocia. There was no evidence that hypoxia/ischaemia contributed to lambs dying of SME. The results of this study suggest that vascular changes in the CNS of newborn lambs may be produced artefactually. Caution is warranted with respect to interpretation of these vascular changes.
NASA Technical Reports Server (NTRS)
Anderson, Karl F. (Inventor); Parker, Allen R., Jr. (Inventor)
1993-01-01
A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.
Gehring, K; Cheng, C H; Nikaido, H; Jap, B K
1991-01-01
We have directly measured the stoichiometry of maltodextrin-binding sites in LamB. Scatchard plots and computer fitting of flow dialysis (rate-of-dialysis) experiments clearly establish three independent binding sites per LamB trimer, with a dissociation constant of approximately 60 microM for maltoheptaose. The current model for LamB's function as a specific pore is discussed with respect to the symmetry in LamB's kinetic properties and the implications of our results. Images PMID:2001992
Ghasemi, Negareh; Zare, Firuz; Davari, Pooya; Vilathgamuwa, Mahinda; Ghosh, Arindam; Langton, Christian; Weber, Peter
2017-02-01
Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric transducer impedance has been discussed in different literatures, the trend of the nonlinearity at different frequencies with respect to excitation voltage variations has not been clearly investigated in practice. In this paper, to demonstrate how the nonlinearity behaves, a sandwich piezoceramic transducer was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30-200V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer. Copyright © 2016 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
7 CFR 1280.208 - Compensation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
Kerr, Nancy J
2007-10-01
A stillborn Suffolk ewe lamb with 2 heads was found to have tarsal arthrogryposis, kypholordosis, craniorachischisis totalis, cheiloschisis, palatoschisis, deviation of the right maxilla, prognathia, patent ductus arteriosus, 3 ventricular septal defects, and 4 great vessels. The lamb was born twin to a normal lamb. No definitive etiology was established.
Myopathy and hepatic lipidosis in weaned lambs due to vitamin E deficiency.
Menzies, Paula; Langs, Lisa; Boermans, Herman; Martin, John; McNally, John
2004-03-01
A sheep flock experienced losses in weaned lambs from myopathy and hepatic lipidosis. Investigation revealed painful ambulation, illthrift, and unexpected death in lambs with normal selenium levels, deficient vitamin E levels, and elevated muscle and liver enzyme levels. Vitamin E deficiency should be considered when investigating myopathy and illthrift in lambs.
Ripoll, G; González-Calvo, L; Molino, F; Calvo, J H; Joy, M
2013-04-01
Indoor-kept concentrate-fed light lambs (n=54) were supplemented with 500 mg of dl-α-tocopheryl acetate/kg concentrate for 0, 10, 20 and 30 d before slaughtering at 22-24 kg BW. Simultaneously, 8 lambs with their dams were alfalfa-grazed and the lambs were slaughtered at the same weight. The age at slaughter and carcass characteristics were more affected by grazing than by supplementation with α-tocopherol. The grazing lambs had similar α-tocopherol levels to the lambs fed concentrate with dl-α-tocopheryl acetate for 10 days before slaughter. The length of the feeding period affected the evolution of the color, delaying the blooming and discoloration of the meat. Feeding lambs α-tocopherol enriched concentrate during the last 10 days of life or grazing them on alfalfa drastically diminished the lipid oxidation of the meat. Alfalfa grazing is a feasible alternative to increase light lamb meat shelf life without using additives. Copyright © 2012 Elsevier Ltd. All rights reserved.
Desclozeaux, Marion; Jelocnik, Martina; Whitting, Katrina; Saifzadeh, Siamak; Bommana, Sankhya; Potter, Andrew; Gerdts, Volker; Timms, Peter; Polkinghorne, Adam
2017-06-14
Arthritis and kerato-conjunctivitis caused by Chlamydia pecorum in lambs are difficult to diagnose and treat. We tested the ability of a prototype C. pecorum vaccine (SC-vaccine), comprised of C. pecorum major outer membrane protein (MOMP-G) and polymorphic membrane protein G (PmpG), to trigger a Chlamydia-specific humoral and cell-mediated immune response in lambs and pregnant ewes. Vaccinations with the SC-vaccine (one and two injections) were very well tolerated by all ewes and lambs. Although the overall immune responses of ewes to SC-vaccination was poor, their lambs showed stronger antigen-specific immune response than lambs from control vaccine ewes. SC-vaccination in lambs triggered production of systemic anti-MOMP-G and anti-PmpG IgG antibodies and secretory IgA in the ocular mucosa. Double vaccination caused statistically significant increases in the height and duration of the humoral response. Antigen-specific IFN-γ was produced in the peripheral blood mononuclear cells of vaccinated lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Oltra, O R; Farmer, L J; Gordon, A W; Moss, B W; Birnie, J; Devlin, D J; Tolland, E L C; Tollerton, I J; Beattie, A M; Kennedy, J T; Farrell, D
2015-02-01
In this study, important eating quality attributes that influence consumer liking for grilled lamb loin have been identified using preference mapping techniques. The eating quality attributes identified as driving the consumer liking of lamb loin steaks were “tenderness”, “sweet flavour”, “meaty aftertaste”, “roast lamb flavour” and “roast lamb aftertaste”. In contrast, the texture attribute “rubbery” and the flavour attributes “bitter flavour” and "bitter aftertaste" had a negative influence on consumer perceptions. Associations were observed between eating quality and a number of instrumental and chemical measurements. Warner Bratzler Shear Force showed an association with “rubbery” texture and a negative association with “tenderness” and consumer liking scores. The compounds, glucose, glucose-6-phosphate, inosine, inosine monophosphate and adenosine monophosphate were associated with the attributes, “sweet flavour”,“meaty aftertaste”, “roast lamb flavour”, “roast lamb aftertaste” and with consumer scores for liking of lamb which is probably caused by the role some of these compounds play as precursors of flavour and as taste compounds.
Iqbal, Muhammad Kashif; Ijaz, Muhammad; Aslam, Hassaan Bin; Farooqi, Shahid Hussain; Ahmad, Syed Saleem; Akhtar, Raheela
2017-11-01
Salmonella enterica (S. enterica) is the major zoonotic threat for small ruminants and humans responsible for huge economic losses and high mortality in Pakistan. Lambs and kids of Lahore district were examined to determine the prevalence, hematology and chemotherapy of S. enterica. A total of 200 diarrheic samples (n=100 lambs; n=100 kids) were collected and examined; 59 (29.50%) were found positive for S. enterica. Lambs had lightly greater prevalence (31%) than kids (29%). The frequency analysis (OR=1.16 [reciprocal =0.87]) showed non-significant difference in both the lambs and kids. The significant decrease (Pℜ0.001) in hemoglobin, pack cell volume and total erythrocyte count was observed in infected lambs and kids. Results of in-vitro antibiotic susceptibility test revealed that S. enteric isolated from both lambs and kids were susceptible to levofloxacin, ciprofloxacin, ofloxacin, gentamicin, azithromycin, tobramycin, amoxicillin, ampicillin and nalidixic acid. Where as the results of in vivo antibiotic trials showed that isolates from both lambs and the kids with diarrhea were susceptible to levofloxacin and ciprofloxacin.
Distribution of volatile branched-chain fatty acids in various lamb tissues.
Brennand, C P; Lindsay, R C
1992-01-01
Volatile fatty acids (C4-C11) including even-, odd-, and branched-chain members in lamb tissues were quantitatively analyzed. Volatile branched-chain fatty acids (BCFA) were more concentrated in subcutaneous adipose tissue samples (rump, shoulder, breast) than in perinepheric adipose or muscle tissues. Perinepheric adipose tissue contained relatively high quantities of n-chain, even-numbered fatty acids and very low levels of BCFA. Greater variation existed in fatty acid profiles among similar subcutaneous adipose tissues from different lambs than between samples of adipose tissue from different carcass sites from a given lamb sample. 4-Methyl- and 4-ethyloctanoic acids were present at concentrations greatly above threshold levels in all lamb fats tested, and thus upon hydrolysis would contribute species-related flavors to lamb. 4-Methylnonanoic concentrations in lamb fats ranged from nondetectable to greater than the threshold level, and therefore this compound would not always contribute to the species-related flavors of lamb. Lean meat samples contained very low concentrations of 4-methyl- and 4-ethyloctanoic acids. Copyright © 1992. Published by Elsevier Ltd.
Effect of aflatoxin on performance, hematology, and clinical immunology in lambs.
Fernández, A; Hernández, M; Verde, M T; Sanz, M
2000-01-01
Twenty-four female lambs were intoxicated with a diet contaminated with 2 ppm aflatoxin for a period of 37 d. Twelve lambs were maintained as the control group. After this period, the lambs were left for 35 d without aflatoxin in their feed. Performance, hematology and clinical immunology were examined in the intoxicated lambs. A non-significant decrease in body weight was observed in the intoxicated lambs during the intoxication period, whereas a significant decrease (P<0.001) in average daily gain was noted on the last day of intoxication and during the clearance period. No significant differences were observed in erythrocyte count, white blood cell count or differential leukocyte count between the groups. Bacteriostatic activity of the serum was lower in the intoxicated lambs, however, there was no effect on serum opsonic activity. Phagocytosis by the neutrophils was higher during the intoxication period and the levels of IgG were elevated in the intoxicated lambs. In vivo cellular immunity was assessed by intradermal injection of phytohemagglutinin; the response was lower during intoxication period. These results indicate that a lowering in the average daily gain was the most sensitive indicator of aflatoxicosis in lambs, and that the immune response was altered, which could render the animals more susceptible to infectious diseases. PMID:10680657
Effect of feeding Mucuna pruriens on helminth parasite infestation in lambs.
Huisden, C M; Adesogan, A T; Gaskin, J M; Courtney, C H; Raji, A M; Kang, T
2010-02-17
Mucuna pruriens is a tropical legume anecdotally reputed to have anthelmintic properties. This study was conducted to examine the validity of such claims. The aim of this study was to determine if ingestion of Mucuna seeds reduces helminth parasite infestation in lambs. Thirty-six Dorper x Katahdin ram lambs were assigned to three treatments, a cottonseed meal based control diet, a diet in which Mucuna replaced cottonseed meal and the control diet with levamisole (7.5mg/kg body weight) administration. All diets were isonitrogenous and isocaloric. The 12 lambs in each treatment were assigned randomly to 4 pens, each containing 3 lambs. Lambs were trickle infected three times per week by gavage with infectious Haemonchus contortus larvae (2000 larvae/lamb) for 3 weeks. Levamisole treatment decreased fecal egg counts by 87% and abomasal worm counts by 83%. Mucuna intake did not statistically affect fecal egg counts or abomasal worm counts, though numerical (P>0.10) reductions of 7.4% and 18.1%, respectively were evident. Anemia indicators, feed intake, and lamb growth were unaffected by treatment. Levamisole reduced the Haemonchus parasite burden in lambs significantly but feeding Mucuna reduced the burden by levels unlikely to eliminate the clinical effects of parasitism. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Czynski, Adam J.; Terry, Michael H.; Deming, Douglas D.; Power, Gordon G.; Buchholz, John N.; Blood, Arlin B.
2013-01-01
Cerebral vessels in the premature newborn brain are well supplied with adrenergic nerves, stemming from the superior cervical ganglia (SCG), but their role in regulation of blood flow remains uncertain. To test this function twelve premature or two-week-old lambs were instrumented with laser Doppler flow probes in the parietal cortices to measure changes in blood flow during changes in systemic blood pressure and electrical stimulation of the SCG. In lambs delivered prematurely at ∼129 days gestation cerebral perfusion and driving pressure demonstrated a direct linear relationship throughout the physiologic range, indicating lack of autoregulation. In contrast, in lambs two-weeks of age, surgical removal of one SCG resulted in ipsilateral loss of autoregulation during pronounced hypertension. Electrical stimulation of one SCG elicited unilateral increases in cerebral resistance to blood flow in both pre-term and two-week-old lambs, indicating functioning neural pathways in the instrumented, anesthetized lambs. We conclude cerebral autoregulation is non-functional in preterm lambs following cesarean delivery. Adrenergic control of cerebral vascular resistance becomes effective in newborn lambs within two-weeks after birth but SCG-dependent autoregulation is essential only during pronounced hypertension, well above the normal range of blood pressure. PMID:24349256
Subharmonics, Chaos, and Beyond
NASA Technical Reports Server (NTRS)
Adler, Laszlo; Yost, William T.; Cantrell, John H.
2011-01-01
While studying finite amplitude ultrasonic wave resonance in a one dimensional liquid-filled cavity, which is formed by a narrow band transducer and a plane reflector, subharmonics of the driver's frequency were observed in addition to the expected harmonic structure. Subsequently it was realized that the system was one of the many examples where parametric resonance takes place and in which the observed subharmonics are parametrically generated. Parametric resonance occurs in any physical system which has a periodically modulated natural frequency. The generation mechanism also requires a sufficiently high threshold value of the driving amplitude so that the system becomes increasingly nonlinear in response. The nonlinear features were recently investigated and are the objective of this presentation. An ultrasonic interferometer with optical precision was built. The transducers were compressional undamped quartz and Lithium Niobate crystals ranging from 1-10 Mhz, and driven by a high power amplifier. Both an optical diffraction system and a receive transducer attached to an aligned reflector with lapped flat and parallel surfaces were used to observe the generated frequency components in the cavity.
ULTRASONIC FLAW DETECTION METHOD AND MEANS
Worlton, D.C.
1961-08-15
A method of detecting subsurface flaws in an object using ultrasonic waves is described. An ultnasonic wave of predetermined velocity and frequency is transmitted to engage the surface of the object at a predetermined angle of inci dence thereto. The incident angle of the wave to the surface is determined with respect to phase velocity, incident wave velocity, incident wave frequency, and the estimated depth of the flaw so that Lamb waves of a particular type and mode are induced only in the portion of the object between the flaw and the surface. These Lamb waves are then detected as they leave the object at an angle of exit equal to the angle of incidence. No waves wlll be generated in the object and hence received if no flaw exists beneath the surface. (AEC)
Belanche, A; Balcells, J; de la Fuente, G; Yañez-Ruíz, D R; Fondevila, M; Calleja, L
2010-10-01
This study examined the reticulo-rumen characteristics of the microbial community and its fermentative characteristics in milk-fed, at weaning and finished lambs in a conventional fattening system. Five lambs were assigned to each of three groups: milk-fed lambs slaughtered at 30 days (T30), weaned lambs slaughtered at 45 days (T45) and 'finished lambs' slaughtered at 90 days (T90). At slaughter, rumen size, fermentation parameters (pH, volatile fatty acids and microbial enzyme activity) and protozoal counts were recorded. Quantitative PCR was used to quantify the genes encoding 16S and 18S ribosomal DNA of the rumen bacterial and protozoal populations, respectively, and the sequential colonization of the rumen by cellulolytic (Ruminococcus albus, Ruminococcus flavefaciens) and amylolytic (Prevotella ruminicola, Streptococcus bovis) bacteria, and protozoa (Entodinium sp.). Denaturing gradient gel electrophoresis was used to study the development of rumen microbiota biodiversity. Intake of solid food before weaning caused a significant increase in rumen weight (p < 0.0001) and bacterial DNA (p < 0.05) and volatile fatty acid analysis concentration (p < 0.01), whereas pH declined. In milk-fed lambs, cellulolytic bacteria were evident after 30 days. Thereafter, in the 45-day and 90-day groups, the proportions of R. flavefaciens decreased and R. albus increased. Amylolytic bacteria were present in milk-fed lambs; the proportion of P. ruminicola increased in fattening lambs and S. bovis was the least abundant species. Protozoal concentrations were irregular; milk-fed lambs had a significant number of protozoa species from Entodinium and subfamily Isotrichiidae, but they disappeared at weaning. Lamb rumen were refaunated in some individuals at 90 days (Entodinium and subfamily Diplodiniinae spp.), although individual concentrations were variable. © 2009 Blackwell Verlag GmbH.
Cassirer, E F; Rudolph, K M; Fowler, P; Coggins, V L; Hunter, D L; Miller, M W
2001-01-01
We conducted field and laboratory experiments to evaluate whether treating pregnant bighorn ewes with a combination of an experimental Pasteurella trehalosi and Mannheimia haemolytica (formerly P. haemolytica) vaccine and a commercially-available bovine P. multocida and M. haemolytica vaccine would increase lamb survival following a pneumonia epidemic. Three free-ranging bighorn herds affected by pasteurellosis outbreaks between November 1995 and June 1996 were included in the field experiment. Post-epidemic lamb survival was low in all three herds in 1996, with November lamb:ewe ratios of < or = 8:100. In March 1997, thirty-six ewes (12/herd) were captured and radiocollared. Half of the ewes captured in each herd were randomly selected to receive both vaccines; the other half were injected with 0.9% saline solution as controls. Lambs born to radiocollared ewes were observed two or more times per week and were considered to have survived if they were alive in October 1997, about 6 mo after birth. Lamb survival differed among herds (range 22% to 100%), and survival of lambs born to vaccinated ewes was lower (P = 0.08) than survival of lambs born to unvaccinated ewes. Bronchopneumonia (pasteurellosis) was the dominant cause of mortality among lambs examined. We concurrently evaluated vaccine effects on survival of lambs born to seven captive ewes removed from the wild during the 1995-96 epidemic. Antibody titers were high in captive ewes prior to vaccination, and vaccines failed to enhance antibody titers in treated captive ewes. None of the captive-born lambs survived. These data suggest that, using existing technology, vaccinating bighorn ewes following pneumonia epidemics has little chance of increasing neonatal survival and population recovery.
Acoustic levitation of a large solid sphere
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrade, Marco A. B., E-mail: marcobrizzotti@gmail.com; Bernassau, Anne L.; Adamowski, Julio C.
2016-07-25
We demonstrate that acoustic levitation can levitate spherical objects much larger than the acoustic wavelength in air. The acoustic levitation of an expanded polystyrene sphere of 50 mm in diameter, corresponding to 3.6 times the wavelength, is achieved by using three 25 kHz ultrasonic transducers arranged in a tripod fashion. In this configuration, a standing wave is created between the transducers and the sphere. The axial acoustic radiation force generated by each transducer on the sphere was modeled numerically as a function of the distance between the sphere and the transducer. The theoretical acoustic radiation force was verified experimentally in a setupmore » consisting of an electronic scale and an ultrasonic transducer mounted on a motorized linear stage. The comparison between the numerical and experimental acoustic radiation forces presents a good agreement.« less
NASA Astrophysics Data System (ADS)
Fan, Xiaofeng; Ha, Kanglyeol; Kim, Moojoon; Kang, Gwansuk; Choi, Min Joo; Oh, Junghwan
2018-07-01
An optoacoustic film transducer was fabricated by coating carbon nanotubes (CNTs) and poly(dimethylsiloxane) (PDMS) on the surface of a thin flexible optical poly(ethylene terephthalate) (PET) sheet. When a laser pulse was irradiated on the film transducer, a shockwave, with superimposed waves reflected from the surface and the back of the film, was generated. The shockwave had very small pulse widths of 20–30 ns, and the maximum pressure of 5.4 MPa was obtained at 10 mm from the surface of the transducer. A line-focused optoacoustic source was fabricated using the film transducer, and its characteristics were investigated. A very high maximum pressure of about 35 MPa was obtained using the source. It was demonstrated that the source can engrave a line trace on a chalk surface.
Effects of early human handling on the pain sensitivity of young lambs.
Guesgen, Mirjam J; Beausoleil, Ngaio J; Stewart, Mairi
2013-01-01
Pain sensitivity of lambs changes over the first weeks of life. However, the effects of early treatments such as human handling on pain sensitivity are unknown for this species. This study investigated the effects of regular early gentle human handling on the pain sensitivity of lambs, indicated by their behavioural responses to tail docking. Prospective part-blinded experimental study. Twenty-nine singleton Coopworth lambs (females n=14, males n=15). Starting at one day of age, lambs were either handled twice daily for 2 weeks (Handled), were kept in the presence of lambs who were being handled but were not handled themselves (Presence), or were exposed to a human only during routine feeding and care (Control). At 3 weeks of age, all lambs were tail docked using rubber rings. Changes in behaviour due to docking were calculated and change data were analyzed using two-way anova with treatment and test pen as main factors. All lambs showed significant increases in the frequency and duration of behaviours indicative of pain, including 'abnormal' behaviours, and decreases in the frequency and duration of 'normal' behaviours after docking. Handled lambs showed a smaller increase in the time spent lying abnormally after docking than did Control lambs (mean transformed change in proportion of 30 minutes spent±SE: Control 0.55±0.04; Handled 0.38±0.03; Presence 0.48±0.03; C versus H t=3.45, p=0.007). These results provide some evidence that handling early in life may reduce subsequent pain sensitivity in lambs. While the behavioural effects of handling on pain behaviour were subtle, the results suggest, at the very least, that early handling does not increase pain sensitivity in lambs and suggests there is still flexibility postnatally in the pain processing system of a precocial species. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
Atkinson, R L; Toone, C D; Ludden, P A
2010-02-01
Four ruminally and duodenally cannulated Suffolk wether lambs (34.5 +/- 2.0 kg initial BW) were used in a 4 x 4 Latin square-designed experiment to examine the effects of ruminal protein degradability and supplementation frequency on site and extent of digestion in lambs consuming a low-quality forage diet. Wethers were fed a basal diet of mature crested wheatgrass hay (4.2% CP) for ad libitum consumption plus 1 of 4 supplements: 1) a high RDP supplement provided daily (RDP-D), 2) the high RDP supplement provided on alternate days (RDP-A), 3) a high RUP supplement provided on alternate days (RUP-A), or 4) a 50:50 mixture of the RDP and RUP supplements, provided on alternate days (MIX-A). Forage OM, N, NDF, or ADF intakes were not affected by treatment. True ruminal OM digestibility was greater (P < 0.001) for MIX-A lambs compared with other treatments. True ruminal N digestibility was less (P < 0.01) in RUP-A lambs compared with other treatments. Ruminal digestibilities of NDF and ADF were greater (P
Burke, J M; Miller, J E; Olcott, D D; Olcott, B M; Terrill, T H
2004-09-02
The objective of the experiment was to determine the optimal dose of copper oxide wire particles (COWPs) to reduce infection of Haemonchus contortus in male lambs. Five to six-month-old hair breed lambs were housed on concrete and fed 450 (L; n = 25) or 675 g (H; n = 25) corn/soybean meal supplement and bermudagrass hay. In July, lambs were inoculated with 10,000 L(3) larvae (97% H. contortus; Day 0). Lambs were administered 0, 2, 4, or 6 g COWP on Day 28. Concentrations of copper in the liver were determined. There were no effects of supplement level on concentrations of copper in the liver and a linear relationship existed between COWP treatment and concentrations of copper in liver (P < 0.001). Least squares means of the 0, 2, 4, 6 g COWP treatments were 62.2, 135.7, 161.1, and 208.4 ppm (P < 0.001). Between Days 0 and 28, PCV declined and by Day 42, PCV of all COWP-treated lambs was markedly higher than control lambs and remained higher (COWP x day, P < 0.05). By Day 21, PCV was greater in the H compared with the L group of lambs (P < 0.001). Within 14 days of COWP treatment FEC declined from more than 8000 eggs/g (epg) to less than 250 epg in all COWP-treated lambs (COWP x day, P < 0.001). The numbers of H. contortus in the abomasum were greatly reduced in all COWP-treated groups of lambs and remaining nematodes were predominantly males. FEC were greater in L versus H supplemented lambs and values decreased to a greater extent in H lambs when treated with COWP (supplement x COWP; P < 0.02). The 2 g COWP was effective in alleviating H. contortus infection and reducing number of egg-laying nematodes in the abomasum with the lowest concentration of copper in the liver of the COWP treatment groups. PCV values were more favorable for lambs fed the higher level of supplement, especially when FEC were greater than 8000 epg.
Curved PVDF airborne transducer.
Wang, H; Toda, M
1999-01-01
In the application of airborne ultrasonic ranging measurement, a partially cylindrical (curved) PVDF transducer can effectively couple ultrasound into the air and generate strong sound pressure. Because of its geometrical features, the ultrasound beam angles of a curved PVDF transducer can be unsymmetrical (i.e., broad horizontally and narrow vertically). This feature is desired in some applications. In this work, a curved PVDF air transducer is investigated both theoretically and experimentally. Two resonances were observed in this transducer. They are length extensional mode and flexural bending mode. Surface vibration profiles of these two modes were measured by a laser vibrometer. It was found from the experiment that the surface vibration was not uniform along the curvature direction for both vibration modes. Theoretical calculations based on a model developed in this work confirmed the experimental results. Two displacement peaks were found in the piezoelectric active direction of PVDF film for the length extensional mode; three peaks were found for the flexural bending mode. The observed peak positions were in good agreement with the calculation results. Transient surface displacement measurements revealed that vibration peaks were in phase for the length extensional mode and out of phase for the flexural bending mode. Therefore, the length extensional mode can generate a stronger ultrasound wave than the flexural bending mode. The resonance frequencies and vibration amplitudes of the two modes strongly depend on the structure parameters as well as the material properties. For the transducer design, the theoretical model developed in this work can be used to optimize the ultrasound performance.
Plastic Muscles TM as lightweight, low voltage actuators and sensors
NASA Astrophysics Data System (ADS)
Bennett, Matthew; Leo, Donald; Duncan, Andrew
2008-03-01
Using proprietary technology, Discover Technologies has developed ionomeric polymer transducers that are capable of long-term operation in air. These "Plastic Muscle TM" transducers are useful as soft distributed actuators and sensors and have a wide range of applications in the aerospace, robotics, automotive, electronics, and biomedical industries. Discover Technologies is developing novel fabrication methods that allow the Plastic Muscles TM to be manufactured on a commercial scale. The Plastic Muscle TM transducers are capable of generating more than 0.5% bending strain at a peak strain rate of over 0.1 %/s with a 3 V input. Because the Plastic Muscles TM use an ionic liquid as a replacement solvent for water, they are able to operate in air for long periods of time. Also, the Plastic Muscles TM do not exhibit the characteristic "back relaxation" phenomenon that is common in water-swollen devices. The elastic modulus of the Plastic Muscle TM transducers is estimated to be 200 MPa and the maximum generated stress is estimated to be 1 MPa. Based on these values, the maximum blocked force at the tip of a 6 mm wide, 35 mm long actuator is estimated to be 19 mN. Modeling of the step response with an exponential series reveals nonlinearity in the transducers' behavior.
Economics of callipyge lamb production.
Busboom, J R; Wahl, T I; Snowder, G D
1999-01-01
This paper examines the economic implications of callipyge (CLPG) lamb production. The price, as it relates to competing meats and excess fat, significantly impact lamb demand, and CLPG genetics improves those factors. The CLPG phenotype does not affect number or weight of lambs weaned or postweaning ADG, but it does improve postweaning feed efficiency by approximately 10%; dressing percentage approximately 7.5%; and yields of wholesale leg (11.8%), loin (4.7%), rack (2.5%), and shoulder (2.3%). Total production costs for a 59-kg lamb are 4% lower in CLPG lambs due to improved feed efficiency. Assuming pelt and offal value pays for slaughter costs, the costs of normal (N) and CLPG carcasses are the same as for live lambs, $81 and $78, respectively; but, due to dressing percentage, the N carcass weighs 29.2 kg and the CLPG carcass, 31.4 kg. Thus, carcass costs for N and CLPG lambs are $2.77/kg and $2.49/kg, respectively. Decreased feed costs, combined with increased carcass and primal cut yields for CLPG lambs, lowers the price required to recover meat costs for leg, loin, rack, and shoulder by 19.7, 14.4, 12.6, and 11.9%, respectively. Successful marketing of CLPG loin and rack depends on the use of one of several postharvest tenderization procedures. Moisture-enhanced pork is accepted by consumers and often sells for a premium; and moisture enhancement may be appropriate for CLPG lamb. The meat cost per kilogram (including a $.10 per kilogram treatment cost) of tenderized and moisture-enhanced CLPG leg, loin, rack, and shoulder containing 10% added water and ingredients would be lowered to $2.51, $4.65, $5.34, and $1.85, respectively. That represents a total of a 20.9% reduction in cost-basis price. When expressed on the basis of increased revenue from the additional yield of cuts at a given market price, the value of CLPG and moisture-enhanced CLPG cuts from a 59-kg lamb would be, respectively, 14.2% and 23.4% higher than for N lamb. Industrywide adoption of CLPG could increase intermediate-run U.S. profits by $109 million, but the actual effects of CLPG attributes, such as a visual appeal, lower fat and cholesterol content, and reduced seam fat, on consumer demand need to be quantified. If accepted by packers and consumers, moisture-enhanced CLPG lamb has the potential to decrease the cost of lamb to consumers and increase lamb industry profitability.
Rajaei Sharifabadi, H; Naserian, A A; Valizadeh, R; Nassiry, M R; Bottje, W G; Redden, R R
2016-08-01
Two experiments were conducted to evaluate the effect of moderate feed restriction on productivity of lambs classified on the basis of phenotypic expression of residual feed intake (RFI). In Exp. 1, 58 fat-tailed Kurdi ram lambs (32.1 ± 4.2 kg BW) were individually fed, ad libitum, a pelleted diet (35% alfalfa hay and 65% concentrate). Feed intake and ADG were determined for a 6-wk period and 3 feed efficiency measures including RFI, G:F, and partial efficiency of maintenance (PEM) were calculated. The lambs were sorted based on RFI and the 16 highest RFI (RFI ≥ mean + 0.5 SD) and 16 lowest RFI (RFI ≤ mean - 0.5 SD) lambs were subjected to body composition (BC) and DM digestibility (DMD) analysis. Feeding behavior traits (FB) were also evaluated for 24 h using a regular 5-min interval observation method. The high- and low-RFI lambs (14 lambs/RFI group) so classified in Exp. 1 were used in Exp. 2. Half of the lambs in each RFI group were randomly selected to be fed ad libitum or 85% of ad libitum (restricted feeding), which resulted in 4 experimental groups: 1) ad libitum high-RFI, 2) feed restricted high-RFI, 3) ad libitum low-RFI, and 4) feed restricted low-RFI. The lambs were fed the same diet as Exp. 1, and growth efficiency during a 6-wk test period as well as BC, DMD, and FB were also determined in Exp. 2. In Exp. 1, the low-RFI lambs consumed 14% ( < 0.01) less feed than high-RFI lambs. Differences were also observed between high- and low-RFI groups for G:F ( = 0.01), RFI ( < 0.01), and PEM ( < 0.01) in Exp. 1, but no differences were detected between high- and low-RFI lambs for ADG ( = 0.79), DMD ( = 0.42), BC ( > 0.72), and FB ( > 0.24). In Exp.2, the restriction feeding regime negatively affected ADG ( < 0.01) and G:F ( = 0.02) in low-RFI lambs, whereas G:F ( = 0.02) and PEM ( < 0.01) were improved in high-RFI lambs under the feed restriction condition. No effects of feed restriction on DMD ( = 0.87) and BC ( > 0.05) were observed. The lambs fed at the restricted level of intake presented a greater time ( < 0.01) and rate ( = 0.01) of eating than those fed ad libitum. Although bunk visits and feeding events were decreased ( < 0.01) with feed restriction, no interaction ( > 0.05) was detected between RFI phenotype and feeding regime for FB. In summary, feeding high-RFI lambs at 85% of ad libitum level improved G:F with no effect on ADG, whereas growth performance was reduced by feeding low-RFI lambs at 85% of ad libitum. However, these changes in feed efficiency were not related to DMD, BC, or FB.
Early experience with diverse foods increases intake of nonfamiliar flavors and feeds in sheep.
Catanese, F; Distel, R A; Provenza, F D; Villalba, J J
2012-08-01
This study determined whether early experiences by sheep with monotonous or diverse diets influence intake of unfamiliar flavors and feeds later in life. Thirty 2-mo-old lambs were randomly assigned to 3 treatment diets (n = 10): diverse (DIV), diverse with plant toxins (DIV+T), and monotonous (MON). Lambs in DIV received in 9 successive periods of exposure 4-way choice combinations of 2 foods high in energy and 2 foods high in protein from an array of 6 foods: 3 high in energy [beet pulp, oat grain, and a mix of milo:grape pomace (60:40)] and 3 high in digestible protein (DP) (soybean meal, alfalfa, corn gluten meal). Lambs in DIV+T received the same exposure as DIV, but 2 plant toxins, oxalic acid (1.5%) and quebracho tannins (10%), were randomly added to 2 of the feeds in each of the choice combinations. Lambs in MON received a monotonous balanced diet, made with a mixture of all 6 feeds detailed before. All treatments received their feed in 4 separate buckets. During exposure, treatments did not differ in total daily DMI (P = 0.31), but daily intake of ME was less (P < 0.02) and daily intake of DP was greater (P < 0.03) for lambs in DIV and DIV+T than for lambs in MON. Treatments did not differ in ADG or G:F (P > 0.05). After exposure, lambs were offered a familiar feed (wheat bran) containing novel flavors (maple, garlic, or bitter) and 2-way choices of novel feeds (fescue hay vs. corn distillers grains, rice vs. calf manna, and green peas vs. rolled oats). Intake of maple-flavored wheat bran tended (P = 0.08) to be greater for lambs in DIV than for lambs in DIV+T and MON. Intake of bitter-flavored and garlic-flavored wheat bran were greater (P = 0.03 and P = 0.04, respectively) for lambs in DIV and DIV+T than for lambs in MON. During 2-way choice trials, lambs in DIV, but not in DIV+T, showed greater intakes of fescue hay (P = 0.05) and rice (P = 0.04) than lambs in MON. Intake of green peas was greater (P = 0.03) for lambs in DIV and DIV+T than for lambs in MON. At the end of testing, lambs in DIV but not in DIV+T showed greater ADG than lambs in MON (P = 0.05). Thus, early exposure to diverse foods enhanced acceptance of novel flavors relative to early exposure to a monotonous ration. Early experience with diverse feeds plus plant toxins led to a less diverse diet than early experience with diverse feeds. Early exposure to diverse feeds may be beneficial in production systems that require rapid acceptance and high intake of unfamiliar feeds.
Coding and quantification of a facial expression for pain in lambs.
Guesgen, M J; Beausoleil, N J; Leach, M; Minot, E O; Stewart, M; Stafford, K J
2016-11-01
Facial expressions are routinely used to assess pain in humans, particularly those who are non-verbal. Recently, there has been an interest in developing coding systems for facial grimacing in non-human animals, such as rodents, rabbits, horses and sheep. The aims of this preliminary study were to: 1. Qualitatively identify facial feature changes in lambs experiencing pain as a result of tail-docking and compile these changes to create a Lamb Grimace Scale (LGS); 2. Determine whether human observers can use the LGS to differentiate tail-docked lambs from control lambs and differentiate lambs before and after docking; 3. Determine whether changes in facial action units of the LGS can be objectively quantified in lambs before and after docking; 4. Evaluate effects of restraint of lambs on observers' perceptions of pain using the LGS and on quantitative measures of facial action units. By comparing images of lambs before (no pain) and after (pain) tail-docking, the LGS was devised in consultation with scientists experienced in assessing facial expression in other species. The LGS consists of five facial action units: Orbital Tightening, Mouth Features, Nose Features, Cheek Flattening and Ear Posture. The aims of the study were addressed in two experiments. In Experiment I, still images of the faces of restrained lambs were taken from video footage before and after tail-docking (n=4) or sham tail-docking (n=3). These images were scored by a group of five naïve human observers using the LGS. Because lambs were restrained for the duration of the experiment, Ear Posture was not scored. The scores for the images were averaged to provide one value per feature per period and then scores for the four LGS action units were averaged to give one LGS score per lamb per period. In Experiment II, still images of the faces nine lambs were taken before and after tail-docking. Stills were taken when lambs were restrained and unrestrained in each period. A different group of five human observers scored the images from Experiment II. Changes in facial action units were also quantified objectively by a researcher using image measurement software. In both experiments LGS scores were analyzed using a linear MIXED model to evaluate the effects of tail docking on observers' perception of facial expression changes. Kendall's Index of Concordance was used to measure reliability among observers. In Experiment I, human observers were able to use the LGS to differentiate docked lambs from control lambs. LGS scores significantly increased from before to after treatment in docked lambs but not control lambs. In Experiment II there was a significant increase in LGS scores after docking. This was coupled with changes in other validated indicators of pain after docking in the form of pain-related behaviour. Only two components, Mouth Features and Orbital Tightening, showed significant quantitative changes after docking. The direction of these changes agree with the description of these facial action units in the LGS. Restraint affected people's perceptions of pain as well as quantitative measures of LGS components. Freely moving lambs were scored lower using the LGS over both periods and had a significantly smaller eye aperture and smaller nose and ear angles than when they were held. Agreement among observers for LGS scores were fair overall (Experiment I: W=0.60; Experiment II: W=0.66). This preliminary study demonstrates changes in lamb facial expression associated with pain. The results of these experiments should be interpreted with caution due to low lamb numbers. Copyright © 2016 Elsevier B.V. All rights reserved.
7 CFR 1280.207 - Term of office.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
NASA Astrophysics Data System (ADS)
Finkel, Peter
2008-03-01
We report on new nondestructive evaluation technique based on electromagnetic modulation of ultrasonic signal for detection of the small crack, flaws and inclusions in thin-walled parts. The electromagnetically induced high density current pulse produces stresses which alter the ultrasonic waves scanning the part with the defect and modulate ultrasonic signal. The excited electromagnetic field can produces crack-opening due to Lorentz forces that increase the ultrasonic reflection. The Joule heating associated with the high density current, and consequent thermal stresses may cause both crack-closure, as well as crack-opening, depending on various factors. Experimental data is presented here for the case of a small crack near holes in thin-walled structures. The measurements were taken at 2-10 MHz with a Lamb wave wedge transducer. It is shown that electromagnetic transient modulation of the ultrasonic echo pulse tone-burst suggest that this method could be used to enhance detection of small cracks and ferromagnetic inclusions in thin walled metallic structures.
Drent, Esther; Groen, Richard W J; Noort, Willy A; Themeli, Maria; Lammerts van Bueren, Jeroen J; Parren, Paul W H I; Kuball, Jürgen; Sebestyen, Zsolt; Yuan, Huipin; de Bruijn, Joost; van de Donk, Niels W C J; Martens, Anton C M; Lokhorst, Henk M; Mutis, Tuna
2016-05-01
Adoptive transfer of chimeric antigen receptor-transduced T cells is a promising strategy for cancer immunotherapy. The CD38 molecule, with its high expression on multiple myeloma cells, appears a suitable target for antibody therapy. Prompted by this, we used three different CD38 antibody sequences to generate second-generation retroviral CD38-chimeric antigen receptor constructs with which we transduced T cells from healthy donors and multiple myeloma patients. We then evaluated the preclinical efficacy and safety of the transduced T cells. Irrespective of the donor and antibody sequence, CD38-chimeric antigen receptor-transduced T cells proliferated, produced inflammatory cytokines and effectively lysed malignant cell lines and primary malignant cells from patients with acute myeloid leukemia and multi-drug resistant multiple myeloma in a cell-dose, and CD38-dependent manner, despite becoming CD38-negative during culture. CD38-chimeric antigen receptor-transduced T cells also displayed significant anti-tumor effects in a xenotransplant model, in which multiple myeloma tumors were grown in a human bone marrow-like microenvironment. CD38-chimeric antigen receptor-transduced T cells also appeared to lyse the CD38(+) fractions of CD34(+) hematopoietic progenitor cells, monocytes, natural killer cells, and to a lesser extent T and B cells but did not inhibit the outgrowth of progenitor cells into various myeloid lineages and, furthermore, were effectively controllable with a caspase-9-based suicide gene. These results signify the potential importance of CD38-chimeric antigen receptor-transduced T cells as therapeutic tools for CD38(+) malignancies and warrant further efforts to diminish the undesired effects of this immunotherapy using appropriate strategies. Copyright© Ferrata Storti Foundation.
Kerr, Nancy J.
2007-01-01
A stillborn Suffolk ewe lamb with 2 heads was found to have tarsal arthrogryposis, kypholordosis, craniorachischisis totalis, cheiloschisis, palatoschisis, deviation of the right maxilla, prognathia, patent ductus arteriosus, 3 ventricular septal defects, and 4 great vessels. The lamb was born twin to a normal lamb. No definitive etiology was established. PMID:17987971
Myopathy and hepatic lipidosis in weaned lambs due to vitamin E deficiency
2004-01-01
Abstract A sheep flock experienced losses in weaned lambs from myopathy and hepatic lipidosis. Investigation revealed painful ambulation, illthrift, and unexpected death in lambs with normal selenium levels, deficient vitamin E levels, and elevated muscle and liver enzyme levels. Vitamin E deficiency should be considered when investigating myopathy and illthrift in lambs. PMID:15072198
NASA Astrophysics Data System (ADS)
Akle, Barbar; Nawshin, Saila; Leo, Donald
2007-04-01
Ionomeric polymer transducers have received considerable attention in the past several years. These actuators, sometimes referred to as artificial muscles, have the ability to generate large bending strain and moderate stress at low applied voltages. As sensors, ionic polymer transducers generate an electric response due to mechanical strain. Typically, ionic polymer transducers are composed of Nafion-117 membranes with platinum electrodes and are saturated with water diluents. Recently the authors have developed a novel fabrication technique called the direct assembly process (DAP), which allowed improved control of the electrode morphology and composition. The DAP consists of spraying two high surface area metal-ionomer electrodes on a Nafion membrane. The benefits of the DAP process over previous methods is the ability to control the thickness of the electrode, the ability to control the composition of the electrode layer of the transducer, and the ability for it to be used with a wide variety of diluents. In past work we have demonstrated that platinum, ruthenium dioxide, and single-walled carbon nanotubes can be used as electrode material with diluents such as water, formamide, and ionic liquids. In this work we will present a reliability study of transducers fabricated using the DAP. Water-hydrated transducers dehydrate and stop moving within 5 min while operating in air under the application of ± 2 V. Ionic liquid based transducers are demonstrated to operate in air for over 400 000 cycles with little loss in performance, and are reliable up to 1 million cycles with a performance loss of less than 43%. The main source of degradation is the adhesion of the conductive surface to the high surface area electrode. This is enhanced in this study by using a PUU linking polymer that has good adhesion properties to gold. Large voltage and large strain are proven to decrease the life of the transducer. Formamide based samples are stable for 3 days under a 1 V actuation signal, while they are only reliable for 3-4 h under a 2 V actuation signal. Solvent evaporation is the main reason for degradation in formamide samples and it is increased at 2 V, indicating some electrochemical activity at such high voltages. Finally the initial drop in performance and the fluctuation in the generated strain are shown to be due to the loss of humidity absorbed from ambient air and the fluctuation in this ambient humidity, respectively.
Smart concrete slabs with embedded tubular PZT transducers for damage detection
NASA Astrophysics Data System (ADS)
Gao, Weihang; Huo, Linsheng; Li, Hongnan; Song, Gangbing
2018-02-01
The objective of this study is to develop a new concept and methodology of smart concrete slab (SCS) with embedded tubular lead zirconate titanate transducer array for image based damage detection. Stress waves, as the detecting signals, are generated by the embedded tubular piezoceramic transducers in the SCS. Tubular piezoceramic transducers are used due to their capacity of generating radially uniform stress waves in a two-dimensional concrete slab (such as bridge decks and walls), increasing the monitoring range. A circular type delay-and-sum (DAS) imaging algorithm is developed to image the active acoustic sources based on the direct response received by each sensor. After the scattering signals from the damage are obtained by subtracting the baseline response of the concrete structures from those of the defective ones, the elliptical type DAS imaging algorithm is employed to process the scattering signals and reconstruct the image of the damage. Finally, two experiments, including active acoustic source monitoring and damage imaging for concrete structures, are carried out to illustrate and demonstrate the effectiveness of the proposed method.
NASA Astrophysics Data System (ADS)
Vilhelm, Jan; Slavík, Lubomír
2014-05-01
For the purpose of non-destructive monitoring of rock properties in the underground excavation it is possible to perform repeated high-accuracy P- and S-wave velocity measurements. This contribution deals with preliminary results gained during the preparation of micro-seismic long-term monitoring system. The field velocity measurements were made by pulse-transmission technique directly on the rock outcrop (granite) in Bedrichov gallery (northern Bohemia). The gallery at the experimental site was excavated using TBM (Tunnel Boring Machine) and it is used for drinking water supply, which is conveyed in a pipe. The stable measuring system and its automatic operation lead to the use of piezoceramic transducers both as a seismic source and as a receiver. The length of measuring base at gallery wall was from 0.5 to 3 meters. Different transducer coupling possibilities were tested namely with regard of repeatability of velocity determination. The arrangement of measuring system on the surface of the rock massif causes better sensitivity of S-transducers for P-wave measurement compared with the P-transducers. Similarly P-transducers were found more suitable for S-wave velocity determination then P-transducers. The frequency dependent attenuation of fresh rock massif results in limited frequency content of registered seismic signals. It was found that at the distance between the seismic source and receiver from 0.5 m the frequency components above 40 kHz are significantly attenuated. Therefore for the excitation of seismic wave 100 kHz transducers are most suitable. The limited frequency range should be also taken into account for the shape of electric impulse used for exciting of piezoceramic transducer. The spike pulse generates broad-band seismic signal, short in the time domain. However its energy after low-pass filtration in the rock is significantly lower than the energy of seismic signal generated by square wave pulse. Acknowledgments: This work was partially supported by the Technology Agency of the Czech Republic, project No. TA 0302408
Herndon, Caroline N.; Shanthalingam, Sudarvili; Knowles, Donald P.; Call, Douglas R.; Srikumaran, Subramaniam
2011-01-01
Mannheimia haemolytica consistently causes fatal bronchopneumonia in bighorn sheep (BHS; Ovis canadensis) under natural and experimental conditions. Leukotoxin is the primary virulence factor of this organism. BHS are more susceptible to developing fatal pneumonia than the related species Ovis aries (domestic sheep [DS]). In BHS herds affected by pneumonia, lamb recruitment is severely impaired for years subsequent to an outbreak. We hypothesized that a lack of maternally derived antibodies (Abs) against M. haemolytica provides an immunologic basis for enhanced susceptibility of BH lambs to population-limiting pneumonia. Therefore, the objective of this study was to determine the titers of Abs directed against M. haemolytica in the sera of BH and domestic lambs at birth through 12 weeks of age. Results revealed that BH lambs had approximately 18-fold lower titers of Ab against surface antigens of M. haemolytica and approximately 20-fold lower titers of leukotoxin-neutralizing Abs than domestic lambs. The titers of leukotoxin-neutralizing Abs in the serum and colostrum samples of BH ewes were approximately 157- and 50-fold lower than those for domestic ewes, respectively. Comparatively, the higher titers of parainfluenza 3 virus-neutralizing Abs in the BH lambs ruled out the possibility that these BHS had an impaired ability to passively transfer Abs to their lambs. These results suggest that lower levels of leukotoxin-neutralizing Abs in the sera of BH ewes, and resultant low Ab titers in their lambs, may be a critical factor in the poor lamb recruitment in herds affected by pneumonia. PMID:21613459
Coulon, Marjorie; Nowak, Raymond; Andanson, Stephane; Petit, Bérengère; Lévy, Frédéric; Boissy, Alain
2015-07-01
Consequences of prenatal stress on emotional reactivity and cognitive abilities in offspring are under-documented in precocial mammals. Here, we investigated to what extent emotional reactivity, judgment bias and spatial learning abilities of lambs are affected by chronic stress during late pregnancy and by their dams' emotional reactivity. The 20 highest-responsive (HR) and 20 lowest-responsive (LR) ewes from a population of 120 Romane ewes were selected according to their pre-mating reactivity to social isolation in a new environment. Over the final third of pregnancy, 10 HR ewes and 10 LR ewes were exposed daily to various unpredictable aversive events such as restraint, mixing groups and transport while the other 20 selected ewes were not. In a human and an object test, prenatally-stressed lambs were more fearful than control lambs, but the prenatal stress effect was moderated by the reactivity of the mothers: prenatally-stressed lambs from ewes with high emotional reactivity were more affected. Prenatally-stressed lambs did not perform as well as control lambs in a maze test and showed pessimistic-like judgment in a cognitive bias test. Prenatally-stressed lambs were thus characterized by a negative affective state with increased fear reactions and impaired cognitive evaluation. The development of negative moods could have long-lasting consequences on the coping strategies of the lambs in response to their rearing conditions. © 2015 Wiley Periodicals, Inc.
Modeling of Piezoelectric Energy Harvesting Using Cymbal Transducers
NASA Astrophysics Data System (ADS)
Kim, Hyeoungwoo; Priya, Shashank; Uchino, Kenji
2006-07-01
This study reports the experimental and analytical results on a piezoelectric cymbal with 29 mm diameter and 1 mm thickness operating under force of 70 N in the frequency range of 10-200 Hz. It was found that the generated power increases with the frequency and around 100 mW can be harvested at frequency of 200 Hz across a 200 kΩ resistor. Power generation from the cymbal transducer was modeled by using the theory developed for the Belleville spring. The calculated results were found to be in good agreement with the experimental results. The results indicate that the metal-ceramic composite transducer “CYMBAL” is the most promising structure for harvesting the electric energy from automobile engine vibrations. The metal cap enhances the endurance of the ceramic to sustain high loads along with stress amplification.
Code of Federal Regulations, 2010 CFR
2010-01-01
... lamb of skeletal origin that is produced in conformance with all applicable Food Safety and Inspection... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS...
Code of Federal Regulations, 2011 CFR
2011-01-01
... lamb of skeletal origin that is produced in conformance with all applicable Food Safety and Inspection... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS...
Code of Federal Regulations, 2012 CFR
2012-01-01
... lamb of skeletal origin that is produced in conformance with all applicable Food Safety and Inspection... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS...
Code of Federal Regulations, 2013 CFR
2013-01-01
... lamb of skeletal origin that is produced in conformance with all applicable Food Safety and Inspection... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS...
Code of Federal Regulations, 2014 CFR
2014-01-01
... lamb of skeletal origin that is produced in conformance with all applicable Food Safety and Inspection... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS...
USDA-ARS?s Scientific Manuscript database
Forty hair-type lambs were examined in a 70-d study to determine the effects of gender (castrate; C vs. intact; I) and forage type on carcass traits and sensory acceptability. Lambs were procured from a single source in Missouri and one-half were randomly castrated. Lambs were randomly assigned to t...
7 CFR 59.303 - Mandatory reporting of lamb carcasses and boxed lamb.
Code of Federal Regulations, 2011 CFR
2011-01-01
... following information on total carlot-based lamb carcass transactions not later than 3 p.m. central time in... per hundredweight on an F.O.B. plant basis; (2) The quantity for each lot of each transaction, quoted... price for each lot of each boxed lamb cut sale, quoted in dollars per hundredweight on a F.O.B. plant...
7 CFR 59.303 - Mandatory reporting of lamb carcasses and boxed lamb.
Code of Federal Regulations, 2012 CFR
2012-01-01
... following information on total carlot-based lamb carcass transactions not later than 3 p.m. central time in... per hundredweight on an F.O.B. plant basis; (2) The quantity for each lot of each transaction, quoted... price for each lot of each boxed lamb cut sale, quoted in dollars per hundredweight on a F.O.B. plant...
7 CFR 59.303 - Mandatory reporting of lamb carcasses and boxed lamb.
Code of Federal Regulations, 2014 CFR
2014-01-01
... following information on total carlot-based lamb carcass transactions not later than 3 p.m. central time in... per hundredweight on an F.O.B. plant basis; (2) The quantity for each lot of each transaction, quoted... price for each lot of each boxed lamb cut sale, quoted in dollars per hundredweight on a F.O.B. plant...
16 CFR 301.9 - Use of terms “Mouton Lamb” and “Shearling Lamb” permitted.
Code of Federal Regulations, 2010 CFR
2010-01-01
... terms “Mouton Lamb” and “Shearling Lamb” permitted. (a) The term Mouton Lamb may be used to describe the skin of a lamb which has been sheared, the hair straightened, chemically treated, and thermally set to produce a moisture repellant finish; as for example: Dyed Mouton Lamb (b) The term Shearling Lamb may be...
7 CFR 59.301 - Mandatory Daily Reporting for Lambs.
Code of Federal Regulations, 2011 CFR
2011-01-01
... shall report to the Secretary at least once each reporting day not later than 2 p.m. central time the... categorized by: (1) The type of purchase; (2) The class of lamb; (3) The quantity of lambs purchased on a live..., quality grade, yield grade, or any type of purchase; (8) Lamb state of origin; (9) The pelt type; and (10...
Consumer Perception of the Quality of Lamb and Lamb Confit
2018-01-01
The patterns of food consumption in general and those of meat, in particular, are constantly changing. These changes are due not only to socioeconomic and cultural trends that affect the whole society but also to the specific lifestyles of consumer groups. Due to the importance of consumer lifestyle, the objectives of this study were (i) to identify the profiles of lamb meat consumers according to their orientation toward convenience, as defined by their eating and cooking habits; (ii) to characterize these profiles according to their socioeconomic characteristics and their preferences regarding the intrinsic and extrinsic quality signals of lamb meat; and (iii) to analyze the willingness to pay for lamb confit. In this study, four types of consumers have been differentiated according to their lifestyles related to lamb consumption. These groups, due to their characteristics, could be called “Gourmet”, “Disinterested”, “Conservative”, and “Basic”. The Gourmet group has characteristics that make it especially interesting to market a product such as lamb confit. However, this group is unaware of this product. Therefore, a possible strategy to expand the commercialization of light lamb and the confit product would be guided marketing to this niche market. PMID:29786652
Consumer Perception of the Quality of Lamb and Lamb Confit.
Ripoll, Guillermo; Joy, Margalida; Panea, Begoña
2018-05-22
The patterns of food consumption in general and those of meat, in particular, are constantly changing. These changes are due not only to socioeconomic and cultural trends that affect the whole society but also to the specific lifestyles of consumer groups. Due to the importance of consumer lifestyle, the objectives of this study were (i) to identify the profiles of lamb meat consumers according to their orientation toward convenience, as defined by their eating and cooking habits; (ii) to characterize these profiles according to their socioeconomic characteristics and their preferences regarding the intrinsic and extrinsic quality signals of lamb meat; and (iii) to analyze the willingness to pay for lamb confit. In this study, four types of consumers have been differentiated according to their lifestyles related to lamb consumption. These groups, due to their characteristics, could be called "Gourmet", "Disinterested", "Conservative", and "Basic". The Gourmet group has characteristics that make it especially interesting to market a product such as lamb confit. However, this group is unaware of this product. Therefore, a possible strategy to expand the commercialization of light lamb and the confit product would be guided marketing to this niche market.
Acoustic cross-correlation flowmeter for solid-gas flow
Sheen, S.H.; Raptis, A.C.
1984-05-14
Apparatus for measuring particle velocity in a solid-gas flow within a pipe includes: first and second transmitting transducers for transmitting first and second ultrasonic signals into the pipe at first and second locations, respectively, along the pipe; an acoustic decoupler, positioned between said first and second transmitting transducers, for acoustically isolating said first and second signals from one another; first and second detecting transducers for detecting said first and second signals and for generating first and second detected signals; and means for cross-correlating said first and second output signals.
Thermal energy harvesters with piezoelectric or electrostatic transducer
NASA Astrophysics Data System (ADS)
Prokaryn, Piotr; Domański, Krzysztof; Marchewka, Michał; Tomaszewski, Daniel; Grabiec, Piotr; Puscasu, Onoriu; Monfray, Stéphane; Skotnicki, Thomas
2014-08-01
This paper describes the idea of the energy harvester which converts thermal gradient present in environment into electricity. Two kinds of such devices are proposed and their prototypes are shown and discussed. The main parts of harvesters are bimetallic spring, piezoelectric transducer or electrostatic transducer with electret. The applied piezomembrane was commercial available product but electrets was made by authors. In the paper a fabrication procedure of electrets formed by the corona discharge process is described. Devices were compared in terms of generated power, charging current, and the voltage across a storage capacitor.
The development of the pupillary light reflex and menace response in neonatal lambs and kids.
Raoofi, Afshin; Mirfakhraie, Pejman; Yourdkhani, Sorush
2011-03-01
The aim of this study was to investigate the development of the pupillary light reflex and menace response in neonatal lambs and goat kids. Thirty lambs and 33 kids were assessed daily from birth until the pupillary light reflex and menace response had become established. All animals had a controlled pupillary light reflex within 20 h of birth. Lambs and kids had developed menace responses by 8 ± 3 and 14 ± 2 days, respectively. The Mann-Whitney test revealed a significant difference (P < 0.001) in the ages at which lambs and kids developed a menace response. Male kids developed this response significantly (P = 0.006) later than females. There was no sex difference in the menace response in the lambs. Overall, the findings indicated that lambs develop a menace response earlier than kids, and female kids develop this response more rapidly than their male counterparts. Copyright © 2010 Elsevier Ltd. All rights reserved.
Lamb Wave Assessment of Fatigue and Thermal Damage in Composites
NASA Technical Reports Server (NTRS)
Seale, Michael D.; Smith, Barry T.; Prosser, W. H.
2004-01-01
Among the various techniques available, ultrasonic Lamb waves offer a convenient method of evaluating composite materials. Since the Lamb wave velocity depends on the elastic properties of a structure, an effective tool exists to monitor damage in composites by measuring the velocity of these waves. Lamb wave measurements can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper describes two studies which monitor fatigue damage and two studies which monitor thermal damage in composites using Lamb waves. In the fatigue studies, the Lamb wave velocity is compared to modulus measurements obtained using strain gage measurements in the first experiment and the velocity is monitored along with the crack density in the second. In the thermal damage studies, one examines samples which were exposed to varying temperatures for a three minute duration and the second includes rapid thermal damage in composites by intense laser beams. In all studies, the Lamb wave velocity is demonstrated to be an excellent method to monitor damage in composites.
Whitney, T R
2017-08-01
Ground woody products and urea are low-cost roughage and N sources. Rambouillet ewe lambs ( = 48, 6 lambs/treatment; initial BW = 42 kg ± 3.8) were used to evaluate effects of using ground (juniper) and urea in supplements on feedlot lamb growth traits, blood serum parameters, and fecal characteristics. In a randomized complete block design (40 d), lambs were individually fed an ad libitum basal sorghum-Sudangrass hay diet, which was fed separate from 1 of 8 supplemental diets (6 lambs/diet; 533 g of supplement/d, as-fed basis). Treatment structure was a 4 × 2 factorial: 4 concentrations of ground juniper (JN: 15%, 30%, 45%, or 60% of DM) and 2 concentrations of urea (UR: 1 or 3% of DM). Lamb growth traits were evaluated on d 0, 5, 12, 19, 26, 33, and 40; blood serum was evaluated on d 6 to 8, 20 to 22, and 34 (at h 3 and 6), and feces was evaluated on d 35. Compared to lambs fed all of the other treatments, lambs fed JN60UR1 or JN60UR3 had reduced supplement DMI (negative quadratic, = 0.007). Hay and total DMI were variable across day (JN × UR × day, < 0.04), but no linear or quadratic trends were detected ( > 0.10). A JN × day interaction was detected ( < 0.001) for lamb BW and the JN × day negative quadratic trend ( = 0.02) for BW was influenced by reduced ADG (linear decrease, < 0.001) of lambs fed JN60. Lambs supplemented with UR3 vs. UR1 tended ( = 0.06) to have reduced BW but had similar ( > 0.17) ADG and G:F. Lamb G:F fluctuated across day (JN × day, = 0.007), but the JN × day quadratic trend ( < 0.001) was mainly due to reduced G:F in lambs fed JN45 or JN60 diets. As the percentage of JN increased in the supplement, serum IGF-1 linearly decreased ( = 0.04), and serum urea N quadratically increased ( < 0.001). The UR × hour interaction ( < 0.001) for serum urea N resulted from a greater decline from 3 to 6 h after feeding in lambs supplemented with UR1 vs. UR3. Increasing JN concentration tended to quadratically increase ( = 0.09) fecal DM and linearly decrease ( = 0.002) fecal N, but an effect due to dietary UR was not detected ( > 0.34). Results indicated that daily supplement DMI was restricted only by using JN60. However, a 60% JN-based supplement will not make an effective rangeland supplement for growing ewe lambs, and using 3% UR should not be considered, especially since daily UR intake was not restricted enough to be considered safe.
Annett, R W; Carson, A F; Dawson, L E R; Kilpatrick, D J
2011-05-01
The objectives of this study were to investigate the effect of dietary lipid source on the growth and carcass characteristics of lambs sourced from a range of crossbred hill ewes. Over a 2-year period, 466 lambs representing the progeny of Scottish Blackface (BF × BF), Swaledale (SW) × BF, North Country Cheviot (CH) × BF, Lleyn (LL) × BF and Texel (T) × BF ewes were sourced from six commercial hill flocks and finished on one of four diets: grass pellets (GP), cereal-based concentrate (CC), CC enriched with oilseed rape (CR) and CC enriched with fish oil (CF). Dry matter intake (DMI) was highest (P < 0.001) in lambs offered GP; however, carcass weight gain (CWG) and feed conversion efficiency were higher (P < 0.001) in lambs fed concentrate-based diets. For lambs offered concentrate-based diets, DMI and live weight gain were lower (P < 0.001) for CF than CC or CR. Lambs with T × BF dams achieved a higher (P < 0.05) daily CWG and CWG/kg DMI than BF × BF, SW × BF or LL × BF dams. When lambs were slaughtered at fat score 3, CH × BF, LL × BF and T × BF dams increased carcass weight by 0.8 to 1.4 kg (P < 0.001) and conformation score (CS) by 0.2 to 0.4 units (P < 0.001) compared with BF × BF or SW × BF dams. However, breed effects on carcass conformation were reduced by 50% when lambs were slaughtered at a constant carcass weight. Diets CC and CR increased carcass weight by 0.8 to 1.6 kg (P < 0.001) and CS by 0.1 to 0.3 units (P < 0.001) compared with GP and CF. Both, dam breed and dietary effects on carcass conformation were associated with an increase (P < 0.001) in shoulder width of the lambs. Lambs fed CF and slaughtered at a constant carcass weight had more subcutaneous fat over the Longissumus dorsi (P < 0.05), Iliocostalis thoracis (P < 0.001) and Obliquus internus abdominis (P < 0.001) compared with those fed CC. However, these effects were removed when lambs were slaughtered at a constant fat score. At both endpoints, lambs from T × BF dams contained less (P < 0.05) perinephric and retroperitoneal fat than SW × BF or LL × BF dams fed GP or CC, respectively. The results from this study show that using crossbred ewes sired by CH, LL or T sires will increase carcass weight and improve carcass conformation of lambs sourced from hill flocks. Inclusion of oilseed rape in lamb finishing diets had only minor effects on performance compared with a standard CC but feeding fish oil or GP impacted negatively on lamb growth and carcass quality.
Candle soot nanoparticles-polydimethylsiloxane composites for laser ultrasound transducers
NASA Astrophysics Data System (ADS)
Chang, Wei-Yi; Huang, Wenbin; Kim, Jinwook; Li, Sibo; Jiang, Xiaoning
2015-10-01
Generation of high power laser ultrasound strongly demands the advanced materials with efficient laser energy absorption, fast thermal diffusion, and large thermoelastic expansion capabilities. In this study, candle soot nanoparticles-polydimethylsiloxane (CSNPs-PDMS) composite was investigated as the functional layer for an optoacoustic transducer with high-energy conversion efficiency. The mean diameter of the collected candle soot carbon nanoparticles is about 45 nm, and the light absorption ratio at 532 nm wavelength is up to 96.24%. The prototyped CSNPs-PDMS nano-composite laser ultrasound transducer was characterized and compared with transducers using Cr-PDMS, carbon black (CB)-PDMS, and carbon nano-fiber (CNFs)-PDMS composites, respectively. Energy conversion coefficient and -6 dB frequency bandwidth of the CSNPs-PDMS composite laser ultrasound transducer were measured to be 4.41 × 10-3 and 21 MHz, respectively. The unprecedented laser ultrasound transduction performance using CSNPs-PDMS nano-composites is promising for a broad range of ultrasound therapy applications.
Characteristics of Ultrasonic Linear Motor that Incorporates Two Transducers at an Acute Angle
NASA Astrophysics Data System (ADS)
Suzuki, Atsuyuki; Tsunoji, Masaki; Tsujino, Jiromaru
2013-07-01
In this study, we have developed an ultrasonic linear motor that incorporates two transducers at an acute angle. The two transducers are used to generate the vertical and horizontal vibration components. The complex vibration is excited using two electrical sources with a phase shift. Ultrasonic motors have unique characteristics such as silent motion and absence of magnetic noise. These characteristics are suitable for use in hospitals and so on. Therefore, we focus on developing actuators for use in a medical bed, specifically a bedsore prevention bed. A study of the vibration characteristics of the motor showed that the resonant frequencies of the transducers were appropriate, although the vibration amplitude of one transducer was less than that of the other. A study of the load characteristics showed that a no-load speed of 267 mm/s and a maximum thrust of 40 N were obtained.
Hart, K J; Sinclair, L A; Wilkinson, R G; Huntington, J A
2011-11-01
Two experiments were conducted to investigate the effect of inclusion of whole-crop pea (WCP) silages, differing in condensed tannin content, as a substitute for grass silage (GS) and soybean meal on lamb metabolism, performance, plasma metabolites, digestibility, and carcass characteristics. In both experiments lambs were offered either solely GS or a 50:50 mix on a DM basis of GS with either low-tannin (LTPS) or high-tannin (HTPS) pea silage ad libitum. Each forage mix was fed with either 400 g/d of low-protein (LP) concentrate or 400 g/d of LP with an additional 200 g/d of pelletized soybean meal (HP), resulting in 6 dietary treatments. Experiment 1 examined the effects of the diets on metabolism, digestibility, and N balance using 6 lambs in 4 periods of 21 d in an incomplete crossover design. Experiment 2 used 48 lambs and examined the effects of the diets on ADG, plasma metabolites, and carcass characteristics over 56 d. Both experiments were analyzed using a 3 × 2 factorial arrangement of treatments. In Exp. 1, lambs offered the LTPS diets had a greater (P < 0.05) digestibility of DM and OM than those offered the GS diets. Lambs offered the WCP silages had an increased (P < 0.05) N intake, N output, and digestibility of GE compared with those offered GS. Mean N digestibility was greatest (P < 0.05) in lambs offered LTPS. Lambs offered HP diets had increased (P < 0.001) digestibility of DM, OM, GE and N, and N- intake, output, retention, and digestibility compared with those offered the LP diets. In Exp. 2, there was no effect (P > 0.05) of forage type on intake, slaughter BW, or feed conversion efficiency (FCE). However, lambs offered the LTPS had a greater (P < 0.05) ADG than those offered the GS diets. Feeding diets containing HP increased (P < 0.001) total DMI, slaughter BW, ADG, and FCE. Lambs offered the WCP had a greater (P < 0.05) plasma β-hydroxybutyrate and urea concentration compared with those offered the GS diets. Feeding lambs HP diets increased (P < 0.05) plasma urea and total protein. Forage mix had no effect (P > 0.05) on carcass composition except for fat depth, which was greater (P < 0.05) in lambs offered WCP silage. Diets containing the HP increased (P < 0.05) carcass weight, hind leg circumference, chop dimensions, and kidney weight. It was concluded that lambs offered LTPS performed better than those offered GS and that LTPS has a concentrate sparing effect. Additionally, the increased tannin concentration in HTPS did not increase performance over lambs offered either GS or LTPS.
Radunz, A E; Fluharty, F L; Susin, I; Felix, T L; Zerby, H N; Loerch, S C
2011-02-01
Mature pregnant crossbred ewes (n = 90) were used in a randomized complete block design experiment and were assigned to 1 of 3 winter-feeding systems differing in primary feed source: haylage (HL), limit-fed corn (CN), or limit-fed dried distillers grains (DDGS). Effects of these winter-feeding strategies on postweaning progeny performance were determined. Lamb progeny (n = 96) were weaned at 61 ± 4 d of age and fed a common high-concentrate diet. Lambs were assigned to feedlot pen (n = 18) based on dam mid-gestation pen. Growth rate, DMI, and ADG were determined for the first 40 d of the finishing period. At 96 ± 4 d of age, 1 wether lamb was randomly selected from each pen (n = 18) for a glucose tolerance test. The experiment was terminated, and lambs were slaughtered individually when they were determined to have achieved 0.6-cm 12th-rib fat thickness. After a 24-h chill, carcass data were collected and a 2.54-cm chop was removed from each lamb from the LM posterior to the 12th rib for ether extract analysis. Additional carcass measurements of bone, muscle, and fat from the shoulder, rack, loin, and leg were collected on 35 carcasses. At weaning, lamb BW was not different among treatments, whereas final BW tended to be greater (P = 0.09) for lambs from ewes fed DDGS and CN during gestation than from those fed HL. Overall lamb growth rate from birth to slaughter was not different among treatments. Lambs from ewes fed DDGS vs. CN or HL tended to have a greater initial insulin response (P = 0.09). Dressing percent was less (P = 0.04) in lambs from ewes fed DDGS, but no difference (P = 0.16) was detected in HCW among treatments. As expected, 12th rib fat thickness was similar among treatments, whereas LM area was largest to smallest (P = 0.05) in lambs from ewes fed CN, HL, and DDGS, respectively. Proportion of internal fat tended to be greatest to smallest (P = 0.06) in lambs from ewes fed DDGS, CN, and HL, respectively. Calculated boneless trimmed retail cuts percentage was less (P = 0.04) in lambs from ewes fed DDGS than CN or HL. Loin muscle weight as a percentage of wholesale cut tended (P = 0.10) to be greater in lambs from ewes fed CN and HL than DDGS, whereas other muscle, bone, and fat weights and proportions were similar (P > 0.24) among treatments. Prepartum diet during mid to late gestation of ewes altered postnatal fat and muscle deposition and may be associated with alterations in insulin sensitivity of progeny.
Electromagnetic midsagittal articulometer systems for transducing speech articulatory movements.
Perkell, J S; Cohen, M H; Svirsky, M A; Matthies, M L; Garabieta, I; Jackson, M T
1992-12-01
This paper describes two electromagnetic midsagittal articulometer (EMMA) systems that were developed for transducing articulatory movements during speech production. Alternating magnetic fields are generated by transmitter coils that are mounted in an assembly that fits on the head of a speaker. The fields induce alternating voltages in a number of small transducer coils that are attached to articulators in the midline plane, inside and outside the vocal tract. The transducers are connected by fine lead wires to receiver electronics whose output voltages are processed to yield measures of transducer locations as a function of time. Measurement error can arise with this method, because as the articulators move and change shape, the transducers can undergo a varying amount of rotational misalignment with respect to the transmitter axes; both systems are designed to correct for transducer misalignment. For this purpose, one system uses two transmitters and biaxial transducers; the other uses three transmitters and single-axis transducers. The systems have been compared with one another in terms of their performance, human subjects compatibility, and ease of use. Both systems can produce useful midsagittal-plane data on articular movement, and each one has a specific set of advantages and limitations. (Two commercially available systems are also described briefly for comparison purposes). If appropriate experimental controls are used, the three-transmitter system is preferable for practical reasons.
Acharya, M; Burke, J M; Coffey, K P; Kegley, E B; Miller, J E; Huff, G R; Smyth, E; Terrill, T H; Mosjidis, J A; Rosenkrans, C
2015-04-01
Sericea lespedeza (SL; Lespedeza cuneata) is a legume rich in condensed tannins that can be grazed or fed to small ruminants for parasite control. Condensed tannins, a secondary plant compound in SL, may lead to unintended consequences such as changes in production. In our preliminary research, there was consistently a reduction in serum and liver concentrations of Mo. The objective of this study was to determine the effect of SL with or without Mo supplementation on changes in BW, hematology, and serum biochemistry in lambs. Thirty ram lambs weaned in May (84 ± 1.5 d of age; 27 ± 1.1 kg) were blocked by BW, breed type (full or three-fourths Katahdin), and EBV of parasite resistance and randomly assigned to be fed 900 g of alfalfa-based supplement (CON; n = 10) or SL-based supplement (n = 20) for 103 d. Supplements were formulated to be isonitrogenous and isocaloric and to meet trace mineral requirements. Within the SL diet, half of the lambs received 490 mg sodium molybdate weekly (SLMO). Body condition scores and BW were determined every 14 d and blood and feces collected to determine hematological and serum biochemical profiles and fecal egg counts (FEC). Data were analyzed using a mixed model with repeated measures and orthogonal contrasts. The white blood cell counts tended to be reduced in SL- and SLMO-fed lambs compared with CON-fed lambs (P < 0.06), which was associated with a reduction in neutrophils (P < 0.001). Red blood cell counts were also reduced in SL but not SLMO lambs compared with CON lambs (P < 0.04). There was a reduction in blood packed cell volume (P < 0.04) and serum concentrations of albumin (P < 0.001) and creatinine (P < 0.02) in both SL and SLMO lambs compared with CON lambs. Similarly, concentrations of blood urea nitrogen were reduced in both SL and SLMO lambs, but differences among dietary treatments disappeared after 42 d of feeding (treatment × day, P < 0.004). Serum concentrations of total proteins were reduced only in SLMO lambs compared with other lambs (P < 0.001). Body weight and FEC were similar among dietary treatments. Means of all measurements were within a normal range, even though there were subtle but significant differences between dietary groups. Feeding a diet high in condensed tannin-rich SL did not lead to serious effects on hematology or serum biochemistry in lambs.
Carcass composition and meat quality of equally mature kids and lambs.
Santos, V A C; Silva, S R; Azevedo, J M T
2008-08-01
Carcass composition and meat quality attributes of 55 suckling kids (27 males and 28 females) and 57 suckling lambs (28 males and 29 females) of Portuguese native breeds were investigated. These suckling kid and lamb meats are European meat quality labels produced according to "Cabrito de Barroso- PGI" and "Borrego Terrincho-PDO" specifications, respectively. Female kids were slaughtered at 9.1 +/- 0.36 kg of BW, and male kids were slaughtered at 10.4 +/- 0.37 kg of BW, corresponding to 20.1 and 17.7% of maturity, respectively. Female lambs were slaughtered at 8.6 +/- 0.53 kg of BW, and male lambs were slaughtered at 9.9 +/- 0.23 kg of BW, corresponding to 19.9 and 17.1% of maturity, respectively. At 24 h postmortem, various yield and quality measurements were collected. The left sides of the carcasses were dissected into muscle, subcutaneous fat, intermuscular fat, and bone. Final pH, instrumental color (L*, a*, b*), carcass measurements, and kidney knob and pelvic fat were also determined. Samples of LM were taken from the lumbar and thoracic cuts for intramuscular and meat quality determinations. At 72 h postmortem, a sample of LM was used for cooking losses and Warner-Bratzler shear force determination. Suckling lambs had greater dressing proportion than suckling kids (P < 0.01). Carcass fatness was not affected by species (P > 0.05), but females had greater kidney knob and pelvic fat proportion than males (P < 0.01). Lambs had greater proportions of the highly valued leg cut and lower proportions of shoulder, anterior rib, and neck cuts than kids. Dissection results indicated that kid carcasses had greater muscle content and lower dissected fat and bone than lambs. Kids had greater (P < 0.001) muscle ultimate pH value than lambs (5.8 +/- 0.02 vs. 5.6 +/- 0.02). Males had greater (P < 0.05) muscle ultimate pH value than females (5.7 +/- 0.02 vs. 5.6 +/- 0.02). The kid meat was significantly lighter (P < 0.05) and less yellow (P < 0.001) than the lamb meat. Kids presented less cooking losses (P < 0.001) than lambs, and shear force value was significantly greater (P < 0.01) in lamb meat. The kid meat had significantly more moisture (P < 0.001) and less intramuscular fat content (P < 0.001) than lambs. At this maturity stage, there were significant differences on both carcass and meat quality attributes of suckling kids and lambs, possibly due to inherent differences between species.
Burke, J M; Miller, J E; Brauer, D K
2005-08-10
The objective of the experiment was to determine the effectiveness of copper oxide wire particles (COWP) in pregnant ewes and safety to lambs. COWP have been used recently as an anthelmintic in small ruminants to overcome problems associated with nematode resistance to chemical dewormers. Doses of COWP (
Whitney, T R; Muir, J P
2010-04-01
Effects of replacing cottonseed hulls with dry redberry juniper leaves on performance and serum NEFA, urea N, and IGF-1 were investigated in Rambouillet lambs (n = 24, initial BW = 28.6 +/- 4.94 kg). In a study with 2 feeding periods (period 1 = 65% concentrate ration, 28 d; period 2 = 85% concentrate ration, 49 d), lambs were individually fed ad libitum treatment diets containing cottonseed hulls (control; CSH), one-half of the cottonseed hulls replaced by dry juniper leaves (CSHJ), or all the cottonseed hulls replaced by dry juniper leaves (JUN). Lamb BW was similar on d 0 and 14, but increasing juniper in the diet linearly reduced (P = 0.04) BW on d 28. Differences in BW during period 1 are attributed to ADG and average daily DMI linearly decreasing (P < 0.001) with increasing concentrations of juniper, with lambs fed CSH, CSHJ, or JUN diets having ADG of 0.34, 0.30, and 0.14 kg, respectively. Differences in average daily DMI are attributed to secondary compounds in the cottonseed hulls and juniper and nutrient-toxin interactions. Lambs fed CSHJ diets had the greatest (P = 0.04) G:F compared with lambs fed CSH and JUN during period 1. Lambs fed JUN diets tended to have the greatest (P = 0.09) NEFA concentrations during period 1, and increasing juniper in the diet linearly reduced (P = 0.006) serum urea N and IGF-1 on d 14 and 28, respectively. During period 2, intake and growth of lambs fed JUN diet rapidly increased, resulting in all lambs having similar ADG, DMI, G:F, and BW. When period 2 began (d 33), serum NEFA and urea N were similar (P > 0.12) among lambs, but serum IGF-1 tended to be linearly reduced (P = 0.09) by increasing juniper in the diet. At times during period 2, lambs fed CSHJ had the greatest (P < 0.02) serum urea N (d 40 and 82) and IGF-1 (d 54) concentrations. Results were interpreted to indicate that air-dried redberry juniper leaves can replace all of the cottonseed hulls in lamb feedlot rations. Feeding 30% juniper in the diet for a longer period of time during the initial feeding period probably would have further reduced growth performance.
Eysker, M; Bakker, N; Kooyman, F N J; Olthuis, S Olde; Ploeger, H W
2006-09-10
In 2004, an experiment was carried out to evaluate the effect of biological control through feeding spores of Duddingtonia flagrans on parasitic gastroenteritis in lambs, kept under an evasive grazing system. In total 66 lambs were used. Forty naturally infected 3-month old ram lambs were weaned in mid June, and divided into four groups of 10 lambs. On 21 June, G1-G4 were moved to four separate virtually clean plots, they were moved after 4 and 8 weeks to similar plots, and housed after 12 weeks to be necropsied 16 days later. The other 26 lambs had been raised helminth-free, and were used as pairs of tracer lambs. All but one of these pairs, were grazed during the last 2 weeks on each plot. The remaining pair (TA) was grazed during the last 2 weeks on pasture (30 August to 13 September) on the plot that had been grazed by G3 between 19 July and 16 August, to study inhibited development in Haemonchus contortus. All lambs were fed 200 g of concentrates daily throughout the whole period, and those of G1 and G2 were also fed 500,000 spores of D. flagrans/kg bodyweight daily. The faecal cultures demonstrated a high reduction in yield as a result of fungal application. However, no differences between groups were seen in weight gain, faecal egg counts, pasture larval counts, worm counts and tracer worm counts. H. contortus was the dominant species, and it is obvious that the moves at 4-week intervals prevented the development of severe haemonchosis. This is in particular demonstrated by the much higher worm counts in the two TA tracer lambs grazed. Nevertheless, increases to high faecal egg counts 3 weeks after the first and second moves, indicated acquisition of infection before these moves and at least subclinical haemonchosis. This was supported with the worm counts of lambs and tracer lambs. A higher proportion of inhibited early L4 than in other tracers and than in the permanent lambs were found in the pair of TA tracer lambs. This indicates that moves to new pastures in late summer and autumn delays the onset of inhibition.
Fullerene reinforced ionic polymer transducer
NASA Astrophysics Data System (ADS)
Jung, J. H.; Cheng, T. H.; Oh, I. K.
2009-07-01
Novel fullerene reinforced nano-composite transducers based on nafion were developed inorder to improve the ionic polymer metal composite transducer. The fullerene reinforced nano-composite membranes were fabricated by recasting method with 0.1 and 0.5 weight percentage of a Fullerenes. Stress-Strain tests showed tremendous increase in stiffness and modulus of the nano-composite membranes even at these minute concentrations of Fullerenes. Ionic exchange capacity analysis and proton conductivity test were performed to calculate the electrical property of the composite films. Water uptake was measured to understand the liquid adsorbing characteristics of the membranes. Also, tip displacement of the nano-composite membrane transducer was investigated under AC excitations with various magnitudes and frequencies. Furthermore, the generated energy was measured from external sinusoidal physical input vibration with several displacements and frequencies by using a mechanical shaker. As a result, the fullerene reinforced nanocomposite membrane based on nafion shows higher stiffness and Young's modulus than that of pure nafion membrane. Also, the nano-composite membrane had better water uptake and proton conductivity than the pure membrane. Fullerene reinforced nano-composite membrane transducer actuates to a much larger deformations than pure nafion membrane transducer. The developed membrane transducer dissipates more energy from the physical input vibration than that of unfilled(or virgin) Nafion membrane transducer.
Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun
2013-04-01
To make full use of the vibrational energy of a longitudinal transducer, a rectangle-type linear ultrasonic motor with four driving feet is proposed in this paper. This new motor consists of four longitudinal vibration transducers which are arranged in a rectangle and form an enclosed construction. Lead zirconate titanate ceramics are embedded into the middle of the transducer and fastened by a wedge-caulking mechanism. Each transducer includes an exponentially shaped horn located on each end. The horns of the vertical transducers intersect at the base of the horizontal transducers' horns; the tip ends of the horizontal transducers' horns are used as the driving feet. Longitudinal vibrations are superimposed in the motor and generate elliptical movements at the tip ends of the horns. The working principle of the proposed motor is analyzed. The resonance frequencies of two working modes are tuned to be close to each other by adjusting the structural parameters. Transient analysis is developed to gain the vibration characteristics of the motor. A prototype motor is fabricated and measured. The vibration test results verify the feasibility of the proposed design. Typical output of the prototype is a no-load speed of 928 mm/s and maximum thrust force of 60 N at a voltage of 200 Vrms.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.128 Wool. Wool means fiber from the fleece of a lamb. ...
NASA Astrophysics Data System (ADS)
Nan, Hao; Boyle, Kevin C.; Apte, Nikhil; Aliroteh, Miaad S.; Bhuyan, Anshuman; Nikoozadeh, Amin; Khuri-Yakub, Butrus T.; Arbabian, Amin
2015-02-01
A radio frequency (RF)/ultrasound hybrid imaging system using airborne capacitive micromachined ultrasonic transducers (CMUTs) is proposed for the remote detection of embedded objects in highly dispersive media (e.g., water, soil, and tissue). RF excitation provides permittivity contrast, and ultra-sensitive airborne-ultrasound detection measures thermoacoustic-generated acoustic waves that initiate at the boundaries of the embedded target, go through the medium-air interface, and finally reach the transducer. Vented wideband CMUTs interface to 0.18 μm CMOS low-noise amplifiers to provide displacement detection sensitivity of 1.3 pm at the transducer surface. The carefully designed vented CMUT structure provides a fractional bandwidth of 3.5% utilizing the squeeze-film damping of the air in the cavity.
USDA-ARS?s Scientific Manuscript database
Quality measures of lamb longissimus dorsi were evaluated in 514 crossbred wether lambs to assess sire breed differences. Wethers were produced over 3 yr from single-sire matings of 22 Columbia, 22 USMARC-Composite (Composite), 21 Suffolk, and 17 Texel rams to adult Rambouillet ewes. Lambs were rear...
Code of Federal Regulations, 2011 CFR
2011-01-01
... or top-cross breed of such sheep, having hair formed in knuckled curls. (b) The term Broadtail Lamb... breed of sheep or top-cross breed of such sheep, having hair formed in flattened knuckled curls with a...; or (2) any other lamb skins having hair in a wavy or open curl pattern. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
... or top-cross breed of such sheep, having hair formed in knuckled curls. (b) The term Broadtail Lamb... breed of sheep or top-cross breed of such sheep, having hair formed in flattened knuckled curls with a...; or (2) any other lamb skins having hair in a wavy or open curl pattern. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
... or top-cross breed of such sheep, having hair formed in knuckled curls. (b) The term Broadtail Lamb... breed of sheep or top-cross breed of such sheep, having hair formed in flattened knuckled curls with a...; or (2) any other lamb skins having hair in a wavy or open curl pattern. ...
Code of Federal Regulations, 2012 CFR
2012-01-01
... or top-cross breed of such sheep, having hair formed in knuckled curls. (b) The term Broadtail Lamb... breed of sheep or top-cross breed of such sheep, having hair formed in flattened knuckled curls with a...; or (2) any other lamb skins having hair in a wavy or open curl pattern. ...
Mellema, Daniel C; Song, Pengfei; Kinnick, Randall R; Urban, Matthew W; Greenleaf, James F; Manduca, Armando; Chen, Shigao
2016-09-01
Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) "push beam" to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. These constraints have limited the implementation of ARF to high-end clinical systems. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity. PROSE generates shear waves using a harmonic mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a "strain-like" compression artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed images were obtained by applying a local frequency estimation (LFE) technique, capable of generating a 2D map from a single frame of shear wave motion. The shear wave imaging frame rate of PROSE is comparable to the vibration frequency, which can be an order of magnitude higher than ARF based techniques. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300 Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥ 19 dB) between the target and background.
Mellema, Daniel C.; Song, Pengfei; Kinnick, Randall R.; Urban, Matthew W.; Greenleaf, James F.; Manduca, Armando; Chen, Shigao
2017-01-01
Ultrasound shear wave elastography (SWE) utilizes the propagation of induced shear waves to characterize the shear modulus of soft tissue. Many methods rely on an acoustic radiation force (ARF) “push beam” to generate shear waves. However, specialized hardware is required to generate the push beams, and the thermal stress that is placed upon the ultrasound system, transducer, and tissue by the push beams currently limits the frame-rate to about 1 Hz. These constraints have limited the implementation of ARF to high-end clinical systems. This paper presents Probe Oscillation Shear Elastography (PROSE) as an alternative method to measure tissue elasticity. PROSE generates shear waves using a harmonic mechanical vibration of an ultrasound transducer, while simultaneously detecting motion with the same transducer under pulse-echo mode. Motion of the transducer during detection produces a “strain-like” compression artifact that is coupled with the observed shear waves. A novel symmetric sampling scheme is proposed such that pulse-echo detection events are acquired when the ultrasound transducer returns to the same physical position, allowing the shear waves to be decoupled from the compression artifact. Full field-of-view (FOV) two-dimensional (2D) shear wave speed images were obtained by applying a local frequency estimation (LFE) technique, capable of generating a 2D map from a single frame of shear wave motion. The shear wave imaging frame rate of PROSE is comparable to the vibration frequency, which can be an order of magnitude higher than ARF based techniques. PROSE was able to produce smooth and accurate shear wave images from three homogeneous phantoms with different moduli, with an effective frame rate of 300Hz. An inclusion phantom study showed that increased vibration frequencies improved the accuracy of inclusion imaging, and allowed targets as small as 6.5 mm to be resolved with good contrast (contrast-to-noise ratio ≥19 dB) between the target and background. PMID:27076352
Eating quality of lamb meat: effects of breed, sex, degree of maturity and nutritional management.
Arsenos, G; Banos, G; Fortomaris, P; Katsaounis, N; Stamataris, C; Tsaras, L; Zygoyiannis, D
2002-04-01
The eating quality of lamb meat of three indigenous Greek dairy breeds of sheep, reared under different nutritional management conditions, was assessed by Taste Panel Tests (TPT). Lean samples from the leg joints of 69 lamb carcasses of the Boutsko (B), Serres (S) and Karagouniko (K) breed were used. For the first TPT, 24 lambs (four males and four females of each breed) were reared in individual pens on a concentrate ration fed ad libitum. For the second TPT, 27 individual penned male lambs were fed on Lucerne hay ad libitum and on three different levels of concentrate: High (H), Medium, (M) and Low (L). For the third TPT, 18 male lambs were used; initially the groups were fed indoors for 63 days on three different levels of concentrate (H, M and L) together with ad libitum Lucerne hay, and subsequently finished on irrigated, sown pasture. For TPT 1, leg joints were obtained from lambs that had been slaughtered at 30, 45, 60 or 90% of mature weight (PMW) for each breed. For TPT 2, lambs were slaughtered at 23, 28 or 33 kg target slaughter live weights (TSLW), common for all breeds. For TPT 3, lambs were slaughtered at 48 or 55% of PMW for each breed. Panellists assessed warm, roasted lean samples of leg joints and rated Flavour, Juiciness, Tenderness and Overall Acceptability. In TPT 1, degree of maturity significantly affected Flavour, Tenderness and Overall Acceptability whereas sex affected only Flavour. In TPT 2, breed and concentrate level significantly affected the quality characteristics, but concentrate level had no significant effect in TPT 3. Effects associated with slaughter weight were significant for most characteristics in all TPT, with decreasing acceptability for older/heavier lambs. Significant interactions were found between breed and the other factors in TPT 2 and TPT 3 for most quality characteristics. Results from these studies suggest changing traditional production systems may enhance the eating quality of lamb meat.
Effect of milk replacer and rumen inert fat on growth and reproduction of Malpura ram lambs.
Kumar, D; Bhatt, R S; Karim, S A; Naqvi, S M K
2014-04-01
The objective of this study was to assess the effects of milk replacer and rumen inert fat on growth, testicular development, puberty, semen production and sperm motion characteristics of ram lambs reared under intensive management in semi-arid climatic conditions. Seven-day-old male lambs of Malpura breed (n=20) were divided equally into two groups. Up to weaning, the lambs in G1 group (control) were fed concentrate, green khejri (Prosopis cineraria) leaves and cowpea (Vigna unguiculata) hay along with suckling of dams, whereas lambs in G2 group were fed reconstituted milk at 17 g/lamb per day for the 1st week and at 34 g/lamb per day from 2nd week in addition to the feed inputs given in G1. During post weaning, lambs in the G1 group were given control concentrate, whereas in G2 the control concentrate supplemented with 40 g rumen inert fat per kg of feed was offered along with dry pala (Zizyphus nummularia) and ardu (Ailanthus excelsa) leaves. BWs of lambs were recorded weekly up to 6 months of age. Ram lambs of both the groups were trained for semen collection at a weekly interval from the age of 5 months and simultaneously testicular measurements were recorded fortnightly. The feeding of milk replacer and rumen inert fat had positive (P<0.05) effects on BW, testicular length, testicular volume, semen volume, sperm concentration, mass motility, % motility, % rapid, medium or slow motile spermatozoa. However, no significant effect was observed on testicular breadth, scrotal circumference, age of puberty, sperm velocities and other CASA-derived parameters. The results of this study indicate that higher plane of nutrition in the form of milk-replacer feeding during preweaning and rumen inert fat-supplemented feed during the postweaning period to growing ram lambs enhances their growth, testicular development and semen quality.
Do Lambs Perceive Regular Human Stroking as Pleasant? Behavior and Heart Rate Variability Analyses
Coulon, Marjorie; Nowak, Raymond; Peyrat, Julie; Chandèze, Hervé; Boissy, Alain; Boivin, Xavier
2015-01-01
Stroking by humans is beneficial to the human-animal relationship and improves welfare in many species that express intraspecific allogrooming, but very few studies have looked at species like sheep that do not express such contact except around parturition. This study investigated the way lambs perceive regular human tactile contact using behavioral and physiological responses. Twenty-four lambs were reared and bucket-fed in groups of four. All were stroked daily by their familiar caregiver. At 8 weeks of age, the lambs were individually tested in their home pen but in a 1×1m open-barred pen after a 15h period of habituation to physical separation from peers while remaining in visual and auditory contact. Half of the lambs received stroking by their caregiver for 8min and half were exposed to their caregiver’s immobile presence. Heart rate and heart rate variability were recorded and analyzed by 2-min slots over the same interval based on three measures: mean heart rate value (HR), root mean square of successive differences (RMSSD) and standard deviation of all intervals measured between consecutive sinus beats (SDNN). Behavioral responses (ear postures of the lamb and time spent in contact with the familiar caregiver, on the knees of the familiar caregiver, and moving) were recorded throughout the test. Lamb HR decreased continuously while in the presence of their caregiver. Lambs being stroked showed slower HR and higher RMSSD which reflected positive emotional states compared to lambs left unstroked. All behavioral variables were highly correlated with the main component axis of the PCA analyses: the more the animals stayed in contact with their caregiver, the less they moved and the more their ears were hanging. This first component clearly differentiates lambs being stroked or not. Behavioral and physiological observations support the hypothesis that gentle physical contact with the caregiver is perceived positively by lambs. PMID:25714604
2013-01-01
The genetic trends in fitness (inbreeding, fertility and survival) of a closed nucleus flock of Menz sheep under selection during ten years for increased body weight were investigated to evaluate the consequences of selection for body weight on fitness. A mate selection tool was used to optimize in retrospect the actual selection and matings conducted over the project period to assess if the observed genetic gains in body weight could have been achieved with a reduced level of inbreeding. In the actual selection, the genetic trends for yearling weight, fertility of ewes and survival of lambs were 0.81 kg, –0.00026% and 0.016% per generation. The average inbreeding coefficient remained zero for the first few generations and then tended to increase over generations. The genetic gains achieved with the optimized retrospective selection and matings were highly comparable with the observed values, the correlation between the average breeding values of lambs born from the actual and optimized matings over the years being 0.99. However, the level of inbreeding with the optimized mate selections remained zero until late in the years of selection. Our results suggest that an optimal selection strategy that considers both genetic merits and coancestry of mates should be adopted to sustain the Menz sheep breeding program. PMID:23783076
Generation of biallelic knock-out sheep via gene-editing and somatic cell nuclear transfer
Li, Honghui; Wang, Gui; Hao, Zhiqiang; Zhang, Guozhong; Qing, Yubo; Liu, Shuanghui; Qing, Lili; Pan, Weirong; Chen, Lei; Liu, Guichun; Zhao, Ruoping; Jia, Baoyu; Zeng, Luyao; Guo, Jianxiong; Zhao, Lixiao; Zhao, Heng; Lv, Chaoxiang; Xu, Kaixiang; Cheng, Wenmin; Li, Hushan; Zhao, Hong-Ye; Wang, Wen; Wei, Hong-Jiang
2016-01-01
Transgenic sheep can be used to achieve genetic improvements in breeds and as an important large-animal model for biomedical research. In this study, we generated a TALEN plasmid specific for ovine MSTN and transfected it into fetal fibroblast cells of STH sheep. MSTN biallelic-KO somatic cells were selected as nuclear donor cells for SCNT. In total, cloned embryos were transferred into 37 recipient gilts, 28 (75.7%) becoming pregnant and 15 delivering, resulting in 23 lambs, 12 of which were alive. Mutations in the lambs were verified via sequencing and T7EI assay, and the gene mutation site was consistent with that in the donor cells. Off-target analysis was performed, and no off-target mutations were detected. MSTN KO affected the mRNA expression of MSTN relative genes. The growth curve for the resulting sheep suggested that MSTN KO caused a remarkable increase in body weight compared with those of wild-type sheep. Histological analyses revealed that MSTN KO resulted in muscle fiber hypertrophy. These findings demonstrate the successful generation of MSTN biallelic-KO STH sheep via gene editing in somatic cells using TALEN technology and SCNT. These MSTN mutant sheep developed and grew normally, and exhibited increased body weight and muscle growth. PMID:27654750
Abo Omar, J M; Omar, M
2012-07-01
Effects of partial substitution of barley grain and soybean meal with fleabane (FB) Conyza bonariensis on growth performances and body compositions of 24 male local Awassi lambs were studied. All lambs were male with an average BW of 20.3 kg (s.d. = 2.0 kg) at the beginning of the experiment. Animals were randomly divided into four groups of six lambs each. Lambs in each group received individually their cereal-soybean-based total mixed rations with levels of FB: 0, 50, 100 and 150 g/kg dry matter (DM) diet, which replaced similar values of barley and soybean meal. All rations were isonitrogenous and isocaloric. The fattening experiment lasted 9 weeks, after which all lambs were slaughtered. The composition of nutrients in the C. bonariensis were 89.6%, 15.0%, 28.0%, 30.0% and 10% for organic matter, CP, NDF, ADF and lignin, respectively. At the end of the experiment, lambs fed 100 and 150 g FB/kg DM diets gained more weight (P < 0.05) than those fed the control and 50 g FB/kg DM diets. The DM intake was lower in lambs fed the highest level of FB compared with intakes of lambs in other treatments. Diet content of FB had significant effect (P < 0.05) on weights of empty body, carcass, gut and external (hide, head and feet) among all animals. However, FB had no effects on lambs' thoracic organs (lungs and heart) and liver. Muscle, bone, omental and mesenteric fat, subcutaneous, intermuscular, pelvic and kidney fat weights (g/kg empty BW) were not affected by FB feeding. Carcass fat was decreased (P < 0.05) by the increase of FB. Total body fat was the same in all animals of the experiment.
Ma, Tao; Deng, Kaidong; Tu, Yan; Zhang, Naifeng; Si, Bingwen; Xu, Guishan; Diao, Qiyu
2017-01-01
Dorper is an important breed for meat purpose and widely used in the livestock industry of the world. However, the protein requirement of Dorper crossbred has not been investigated. The current paper reports the net protein (NP) and metabolizable protein (MP) requirements of Dorper crossbred ram lambs from 20 to 35 kg BW. Thirty-five Dorper × thin-tailed Han crossbred lambs weaned at approximately 50 d of age (20.3 ± 2.15 kg of BW) were used. Seven lambs of 25 kg BW were slaughtered as the baseline animals at the start of the trial. An intermediate group of seven randomly selected lambs fed ad libitum was slaughtered at 28.6 kg BW. The remaining 21 lambs were randomly divided into three levels of dry matter intake: ad libitum or 70% or 40% of ad libitum intake. Those lambs were slaughtered when the lambs fed ad libitum reached 35 kg BW. Total body N and N retention were measured. The daily NP and MP requirements for maintenance were 1.89 and 4.52 g/kg metabolic shrunk BW (SBW 0.75 ). The partial efficiency of MP utilization for maintenance was 0.42. The NP requirement for growth ranged from 12.1 to 43.5 g/d, for the lambs gaining 100 to 350 g/d, and the partial efficiency of MP utilization for growth was 0.86. The NP and MP requirements for the maintenance and growth of Dorper crossbred male lambs were lower than the recommendations of American and British nutritional systems.
Santos, A; Valdés, C; Giráldez, F J; López, S; France, J; Frutos, J; Fernández, M; Andrés, S
2018-01-24
The present study was designed to describe the effects of early feed restriction of Merino lambs on feed efficiency during the fattening period by examining ruminal microbiota and fermentation parameters, gastrointestinal morphology, digestibility or liver proteome. In total, 24 male Merino lambs were randomly assigned to two experimental treatments (n=12 per treatment). Lambs of the first group (ad libitum (ADL)) were kept permanently with the dams, whereas the other 12 lambs (restricted (RES)) were milk restricted. When lambs reached a live BW (LBW) of 15 kg, all the animals were offered the same complete pelleted diet (35 g dry matter/kg LBW per day) until slaughter at a LBW of 27 kg. The RES lambs showed poorer feed efficiency during the fattening period when compared with the ADL group (feed to gain ratio, 3.69 v. 3.05, P<0.001). No differences were observed in ruminal microbiota, fermentation parameters or apparent digestibility. However, the proportion of the small intestine and the length of ileal villi were reduced in the RES lambs. In total, 26 spots/proteins were identified in the liver proteomic profile, with significant differences (P<0.05) between experimental treatments, suggesting a higher catabolism of proteins and a reduction in β-oxidation of fatty acids in RES lambs when compared with the ADL animals. In conclusion, early feed restriction of Merino lambs during the suckling period promotes long-term effects on the small intestine and the proteomic profile of the liver, which may influence the metabolic use of nutrients, thus negatively affecting feed efficiency during the fattening phase.
Energy requirements of Texel crossbred lambs.
Galvani, D B; Pires, C C; Kozloski, G V; Wommer, T P
2008-12-01
Two trials were conducted to determine the energy requirements of feedlot Texel crossbred lambs. In a comparative slaughter trial, thirty 11/16 Texel x 5/16 Ile de France crossbred noncastrated male lambs, weaned at 42 d of age (16.2 +/- 2.1 kg of shrunk BW; SBW), were used. Five lambs were randomly chosen and slaughtered after 10 d of experimental management and diet adaptation (baseline group). Fifteen lambs then were fed for ad libitum intake and slaughtered at 25, 30, or 35 kg of SBW. The remaining 10 lambs were randomly assigned to 2 levels of DMI, either 70 or 55% of the ad libitum intake, and were slaughtered concomitantly with lambs of the 35 kg of SBW group. Total body N, fat, and energy contents were determined. In a digestibility trial, 6 Texel x Ile de France crossbred lambs (30.4 +/- 2.6 kg of SBW) were housed in metabolic cages and used in a replicated 3 x 3 Latin square experiment to evaluate the energetic value of the diet at different feed intake levels. Net and ME requirements for maintenance were 58.6 and 91 kcal/kg(0.75) of SBW, respectively. Consequently, partial efficiency of energy use for maintenance was 0.64. Body fat content varied from 72.7 to 125.9 g/kg of empty BW, respectively, for 13.1 and 28.2 kg of empty BW. Net energy requirements for growth of lambs at 15 and 35 kg of SBW at an ADG of 250 g were 424 and 553 kcal/d, respectively. Partial efficiency of energy use for growth was 0.47. Texel x Ile de France crossbred growing lambs used in this study showed decreased nutritional requirements than those reported by most nutritional systems.
Stable isotopes to discriminate lambs fed herbage or concentrate both obtained from C(3) plants.
Moreno-Rojas, Jose M; Vasta, Valentina; Lanza, Alfio; Luciano, Giuseppe; Ladroue, Virginie; Guillou, Claude; Priolo, Alessandro
2008-12-01
This study was aimed at determining whether isotopic ratio mass spectrometry (IRMS) enables us to discriminate between lambs fed herbage or concentrate, both obtained from C(3) plants, and those fed a concentrate obtained from C(4) plants. Thirty-four Comisana male lambs (age 45 days) were assigned to three feeding treatments. Fourteen lambs were fed vetch (Vicia sativa) ad libitum. Another fourteen lambs received a barley-based concentrate. The remaining six lambs were fed a maize-based concentrate. After 60 days of experimental treatment the animals were slaughtered and the wool, perirenal fat and muscle longissimus dorsi were sampled. The delta(13)C and delta(15)N values of the muscle, wool and feed were measured by continuous flow elemental analysis (CF-EA)-IRMS. The delta(13)C of the fat was determined likewise. The isotopic composition of the tissues reflected that of the three diets. For the lambs which were fed herbage the muscle delta(13)C values were higher (P < 0.0005) and delta(15)N values were lower (P < 0.0005) than those of the lambs receiving concentrates. The delta(15)N and delta(13)C values in the muscle and delta(13)C values in the adipose tissue allowed perfect discrimination between the lambs fed the three different diets. The regression between the delta(13)C values measured in muscle and in wool of lambs was linear (R(2) = 0.99; P < 0.0005). This result shows that delta(13)C measured in the wool can predict muscle delta(13)C distribution, suggesting that wool is a valuable matrix for meat authentication.
Syndecan-1 and Metastasis Dormancy
2015-09-01
Sdc1 WT vs Sdc1 KO mice (p = 0.36). - 5 - Major Task 2: Optimize 3D lung microenvironment assay Subtask 1: Transduce HMVEC-L with E4ORF1 and mCherry...micro-channel devices (see below) but have not yet transduced them with E4ORF1 nor labeled them. If we succeed in generating defined vascular
Enhanced Thermal Ablation by Combining Ultrasound Contrast Agents with a Miniature Flat Transducer
NASA Astrophysics Data System (ADS)
Murillo, A.; Goldendstedt, C.; Lafon, C.; Cathignol, D.; Chapelon, J.-Y.
2007-05-01
Miniature transducers can be used for performing interstitial thermal ablation. Increasing the frequency of non-focused transducers enhances energy deposition but limits the therapeutic range. In order to treat extended tumors, new therapeutic strategies must be explored. This work aimed to combine ultrasound contrast agents (UCA) with flat transducers for increasing the treatment depth. The idea consists in increasing attenuation away from the transducer to favor remote heat deposition. Thermal ablation is induced in three steps. 1- Attenuation raises by injecting UCA; 2- Destruction of bubbles next to the transducer by pulsed high intensity bursts, results in a gradient of attenuation; 3- Continuous ultrasound are applied for generating a localized thermal lesion. In vitro tests were performed on temperature-sensitive tissue phantoms in which the UCA BR14 (Bracco) was injected during the liquid phase. The feasibility of the idea was demonstrated in three stages. 1- The coefficient of attenuation was measured with the force balance as a function of the concentration of BR14. For 0.8 and 4.8% attenuation at 10MHz was found to be 0.35 and 1.33 Np/cm respectively. 2- Pulsed ultrasound was applied on phantoms to destroy UCA. Based on the echogenicity decay evidenced on ultrasound images, a 1MPa-pressure was required at 10MHz. 3- Heating beams were applied on phantoms presenting a gradient in attenuation. Lesions were 1.5 times larger than in phantoms with constant attenuation. This study demonstrates that UCA can be selectively destroyed in order to generate a gradient of attenuation and extended thermal lesions.
7 CFR 1280.129 - Wool products.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.129 Wool products. Wool..., excluding pelts. Lamb Promotion, Research, and Information Board ...
[Liposomal-amphotericin B efficacy and safety].
Hamada, Yukihiro; Komatsu, Toshiaki; Seto, Yoshinori; Matsubara, Hajime; Kume, Hikaru; Sunakawa, Keisuke; Yago, Kazuo
2010-03-01
Liposomal amphotericin B (L-AMB), a lipid-based amphotericin B formulation, has been used in Japan since June 2006 to treat fungal infection. In the 3 years since L-AMB was launched, few reports have been made on its status. To ensure its appropriate use, we restrospectively reviewed its efficacy and safety in treating fungal infections. 25 subjects with fungal infection treated with L-AMB from April 2007 until February 2008. Of those, 16 showed clinical improvement. Elevated serum creatinine occurred in 1 and decreased serum potassium in 6. We found a positive relationship between the serum potassium decrease and L-AMB dose. Logistic regression analysis of this relationship showed that serum potassium tended to fall on day 5 to 6 of L-AMB administration. While L-AMB appears highly effective in fungal infection, it requires serum potassium monitoring to ensure patient safety.
Angell, J W; Jones, G L; Voigt, K; Grove-White, D H
2013-08-31
Drunken lamb syndrome (DLS) has recently been described as lamb D-lactic acidosis syndrome (LDLAS). In 2012, 18 lambs aged between 7 days and 28 days with LDLAS were identified. Biochemically, each lamb had a metabolic acidosis characterised by D-lactic acidosis and exhibited clinical signs including: not hyperthermic, no evidence of dehydration, demonstrating an ataxic gait tending to recumbency (DLS) and possibly somnolence. These lambs received 50 mmol of sodium bicarbonate as an 8.4 per cent solution given orally, together with parenteral long-acting amoxicillin. All 18 cases made a full clinical recovery. This study demonstrates a novel effective treatment for a disease that is usually fatal, and also demonstrates a strong correlation between venous plasma bicarbonate concentrations and venous plasma D-lactate concentrations (R(2)=0.49).
Lamb Wave Tomography for Corrosion Mapping
NASA Technical Reports Server (NTRS)
Hinders, Mark K.; McKeon, James C. P.
1999-01-01
As the world-wide civil aviation fleet continues to age, methods for accurately predicting the presence of structural flaws-such as hidden corrosion-that compromise airworthiness become increasingly necessary. Ultrasonic guided waves, Lamb waves, allow large sections of aircraft structures to be rapidly inspected. However, extracting quantitative information from Lamb wave data has always involved highly trained personnel with a detailed knowledge of mechanical-waveguide physics. Our work focuses on using a variety of different tomographic reconstruction techniques to graphically represent the Lamb wave data in images that can be easily interpreted by technicians. Because the velocity of Lamb waves depends on thickness, we can convert the travel times of the fundamental Lamb modes into a thickness map of the inspection region. In this paper we show results for the identification of single or multiple back-surface corrosion areas in typical aluminum aircraft skin structures.
Gentle vs. aversive handling of pregnant ewes: II. Physiology and behavior of the lambs.
Coulon, M; Hild, S; Schroeer, A; Janczak, A M; Zanella, A J
2011-07-06
We compared the effects of aversive and gentle handling in late pregnant ewes on fearfulness, heart rate variability and spatial learning in lambs. Twenty-four Norwegian-Dala ewes were studied. Ewes were subjected to gentle (i.e. soft talking and calm behavior) or aversive handling (i.e. swift movements and shouting) for 10 min twice a day during the last five weeks of pregnancy. Lambs from aversively (AVS) or gently (GEN) treated ewes were tested at 4 weeks of age. Lamb behavior was recorded during a) a human approach test, composed of 4 min of isolation and 4 min of exposure to an unfamiliar human, b) an umbrella startle test followed by 5-min recording, and c) two repetitions of a maze test. In addition, heart rate variability was recorded telemetrically before and after the human and startle tests. The baseline heart rate variability measures suggested a lower influence of vagal stimulation in AVS lambs. In the human approach test, AVS lambs vocalized and explored the environment less, and were slower to approach the human. They also tended to have higher flight distances during the startle test than the GEN lambs. The prenatal treatment had no significant effect in the maze test. In conclusion, we showed that aversive handling of pregnant ewes increased fearfulness and reduced vagal tone in their progeny compared to GEN lambs. These effects can have consequences for how lambs cope with rearing conditions. Copyright © 2011 Elsevier Inc. All rights reserved.
Lamb survival analysis from birth to weaning in Iranian Kermani sheep.
Barazandeh, Arsalan; Moghbeli, Sadrollah Molaei; Vatankhah, Mahmood; Hossein-Zadeh, Navid Ghavi
2012-04-01
Survival records from 1,763 Kermani lambs born between 1996 and 2004 from 294 ewes and 81 rams were used to determine genetic and non-genetic factors affecting lamb survival. Traits included were lamb survival across five periods from birth to 7, 14, 56, 70, and 90 days of age. Traits were analyzed under Weibull proportional hazard sire models. Several binary analyses were also conducted using animal models. Statistical models included the fixed class effects of sex of lamb, month and year of birth, a covariate effect of birth weight, and random genetic effects of both sire (in survival analyses) and animal (in binary analyses). The average survival to 90 days of age was 94.8%. Hazard rates ranged from 1.00 (birth to 90 days of age) to 1.73 (birth to 7 days of age) between the two sexes indicating that male lambs were at higher risk of mortality than females (P < 0.01). This study also revealed a curvilinear relationship between lamb survival and lamb birth weight, suggesting that viability and birth weight could be considered simultaneously in the selection programs to obtain optimal birth weight in Kermani lambs. Estimates of heritabilities from survival analyses were medium and ranged from 0.23 to 0.29. In addition, heritability estimates obtained from binary analyses were low and varied from 0.04 to 0.09. The results of this study suggest that progress in survival traits could be possible through managerial strategies and genetic selection.
Zonabend König, E; Ojango, J M K; Audho, J; Mirkena, T; Strandberg, E; Okeyo, A M; Philipsson, J
2017-01-01
Meat production is the most important trait in the breeding objectives of sheep production in East Africa. The aim of this study was to investigate breed differences in live weight, conformation, carcass traits and economic values for meat production among Red Maasai and Dorper sheep and their crosses. In total, 88 ram lambs, which were reared at the ILRI experimental station, Kapiti plains Estate in Central Kenya, were used for the study. The lambs were slaughtered at Kenya Meat Commission (KMC) at about 1 year of age. Prior to slaughter, the lambs were weighed, measured and assessed by experienced evaluators, and at the abattoir carcass traits were recorded. Large breed differences were found for most traits. Dorper lambs were heavier at delivery for slaughter and had better carcass grade but lower dressing percentage and fat levels than Red Maasai. Crossbreds were generally better than the parental breeds. Evaluators were willing to pay more for the Dorper lambs for slaughter although carcass weights later were shown not to be higher than for Red Maasai. Evaluators undervalued Red Maasai lambs by 8-13 % compared to Dorper lambs according to the prices quoted per kilogramme live or carcass weight by KMC. Live weight was better than any other live measure in predicting carcass weight. Due to the overall higher ranking of the crossbred lambs for meat production, Dorper may be useful as a terminal sire breed for crossing with Red Maasai ewes.
System for generating a beam of acoustic energy from a borehole, and applications thereof
Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian; Nihei, Kurt T.; Schmitt, Denis P.; Skelt, Christopher
2012-09-04
In some aspects of the invention, a device, positioned within a well bore, configured to generate and direct an acoustic beam into a rock formation around a borehole is disclosed. The device comprises a source configured to generate a first signal at a first frequency and a second signal at a second frequency; a transducer configured to receive the generated first and the second signals and produce acoustic waves at the first frequency and the second frequency; and a non-linear material, coupled to the transducer, configured to generate a collimated beam with a frequency equal to the difference between the first frequency and the second frequency by a non-linear mixing process, wherein the non-linear material includes one or more of a mixture of liquids, a solid, a granular material, embedded microspheres, or an emulsion.
System for generating a beam of acoustic energy from a borehole, and applications thereof
Vu, Cung Khac [Houston, TX; Sinha, Dipen N [Los Alamos, NM; Pantea, Cristian [Los Alamos, NM; Nihei, Kurt T [Oakland, CA; Schmitt, Denis P [Katy, TX; Skelt, Christopher [Houston, TX
2012-07-31
In some aspects of the invention, a device, positioned within a well bore, configured to generate and direct an acoustic beam into a rock formation around a borehole is disclosed. The device comprises a source configured to generate a first signal at a first frequency and a second signal at a second frequency; a transducer configured to receive the generated first and the second signals and produce acoustic waves at the first frequency and the second frequency; and a non-linear material, coupled to the transducer, configured to generate a collimated beam with a frequency equal to the difference between the first frequency and the second frequency by a non-linear mixing process, wherein the non-linear material includes one or more of a mixture of liquids, a solid, a granular material, embedded microspheres, or an emulsion.
Wichgers Schreur, Paul J.; van Keulen, Lucien; Kant, Jet; Oreshkova, Nadia; Moormann, Rob J. M.; Kortekaas, Jeroen
2016-01-01
Rift Valley fever virus (RVFV) is transmitted among susceptible animals by mosquito vectors. Although the virus can be isolated from nasal and oral swabs of infected animals and is known to be highly infectious when administered experimentally via oral or respiratory route, horizontal transmission of the virus is only sporadically reported in literature. We considered that immunosuppression resulting from stressful conditions in the field may increase the susceptibility to horizontally transmitted RVFV. Additionally, we reasoned that horizontal transmission may induce immune responses that could affect the susceptibility of contact-exposed animals to subsequent infection via mosquito vectors. To address these two hypotheses, viremic lambs were brought into contact with sentinel lambs. One group of sentinel lambs was treated with the immunosuppressive synthetic glucocorticosteroid dexamethasone and monitored for signs of disease and presence of virus in the blood and target organs. Another group of contact-exposed sentinel lambs remained untreated for three weeks and was subsequently challenged with RVFV. We found that none of the dexamethasone-treated contact-exposed lambs developed detectable viremia, antibody responses or significant increases in cytokine mRNA levels. Susceptibility of immunocompetent lambs to RVFV infection was not influenced by previous contact-exposure. Our results are discussed in light of previous findings. PMID:27014211
Zhang, Shuzeng; Li, Xiongbing; Jeong, Hyunjo; Hu, Hongwei
2018-05-12
Angle beam wedge transducers are widely used in nonlinear Rayleigh wave experiments as they can generate Rayleigh wave easily and produce high intensity nonlinear waves for detection. When such a transducer is used, the spurious harmonics (source nonlinearity) and wave diffraction may occur and will affect the measurement results, so it is essential to fully understand its acoustic nature. This paper experimentally investigates the nonlinear Rayleigh wave beam fields generated and received by angle beam wedge transducers, in which the theoretical predictions are based on the acoustic model developed previously for angle beam wedge transducers [S. Zhang, et al., Wave Motion, 67, 141-159, (2016)]. The source of the spurious harmonics is fully characterized by scrutinizing the nonlinear Rayleigh wave behavior in various materials with different driving voltages. Furthermore, it is shown that the attenuation coefficients for both fundamental and second harmonic Rayleigh waves can be extracted by comparing the measurements with the predictions when the experiments are conducted at many locations along the propagation path. A technique is developed to evaluate the material nonlinearity by making appropriate corrections for source nonlinearity, diffraction and attenuation. The nonlinear parameters of three aluminum alloy specimens - Al 2024, Al 6061 and Al 7075 - are measured, and the results indicate that the measurement results can be significantly improved using the proposed method. Copyright © 2018. Published by Elsevier B.V.
Validation of a hybrid electromagnetic-piezoelectric vibration energy harvester
NASA Astrophysics Data System (ADS)
Edwards, Bryn; Hu, Patrick A.; Aw, Kean C.
2016-05-01
This paper presents a low frequency vibration energy harvester with contact based frequency up-conversion and hybrid electromagnetic-piezoelectric transduction. An electromagnetic generator is proposed as a power source for low power wearable electronic devices, while a second piezoelectric generator is investigated as a potential power source for a power conditioning circuit for the electromagnetic transducer output. Simulations and experiments are conducted in order to verify the behaviour of the device under harmonic as well as wide-band excitations across two key design parameters—the length of the piezoelectric beam and the excitation frequency. Experimental results demonstrated that the device achieved a power output between 25.5 and 34 μW at an root mean squared (rms) voltage level between 16 and 18.5 mV for the electromagnetic transducer in the excitation frequency range of 3-7 Hz, while the output power of the piezoelectric transducer ranged from 5 to 10.5 μW with a minimum peak-to-peak output voltage of 6 V. A multivariate model validation was performed between experimental and simulation results under wide-band excitation in terms of the rms voltage outputs of the electromagnetic and piezoelectric transducers, as well as the peak-to-peak voltage output of the piezoelectric transducer, and it is found that the experimental data fit the model predictions with a minimum probability of 63.4% across the parameter space.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.106 Exporter. Exporter means any person who exports domestic live lambs from the United States. ...
Liu, Huawei; Li, Ke; Mingbin, Lv; Zhao, Jinshan; Xiong, Benhai
2016-06-01
A study was conducted to evaluate the effects of chestnut tannins (CT) on the meat quality, welfare and antioxidant status of heat-stressed lambs. Lambs in one group were raised at 20°C and fed a basal diet (N), and three other groups (32°C) were fed a basal diet with 0 (CT0), 5 (CT5), and 10 g (CT10) of CT/kg. Addition of CT increased the b* and L* values of meat and superoxide dismutase and glutathione peroxidase activity in the serum and liver of heat-stressed lambs. The malondialdehyde concentration in meat, serum, and liver of heat-stressed lambs was decreased by dietary CT supplementation. Lambs in the CT0 group had higher cortisol, T3, and T4 levels, creatine kinase activity, white blood cell count, neutrophil count, neutrophil:lymphocyte ratio and a lower lymphocyte count than that in the N and CT10 groups. In conclusion, the addition of CT improved meat quality, certain stress parameters, and the antioxidant status of heat-stressed lambs. Copyright © 2016 Elsevier Ltd. All rights reserved.
López-Andrés, Patricia; Luciano, Giuseppe; Vasta, Valentina; Gibson, Trevor M; Biondi, Luisa; Priolo, Alessandro; Mueller-Harvey, Irene
2013-08-01
A total of sixteen lambs were divided into two groups and fed two different diets. Of these, eight lambs were fed a control diet (C) and eight lambs were fed the C diet supplemented with quebracho tannins (C+T). The objective of the present study was to assess whether dietary quebracho tannins can improve the antioxidant capacity of lamb liver and plasma and if such improvement is due to a direct transfer of phenolic compounds or their metabolites, to the animal tissues. Feed, liver and plasma samples were purified by solid-phase extraction (SPE) and analysed by liquid chromatography-MS for phenolic compounds. Profisitinidin compounds were identified in the C+T diet. However, no phenolic compounds were found in lamb tissues. The liver and the plasma from lambs fed the C+T diet displayed a greater antioxidant capacity than tissues from lambs fed the C diet, but only when samples were not purified with SPE. Profisetinidin tannins from quebracho seem not to be degraded or absorbed in the gastrointestinal tract. However, they induced antioxidant effects in animal tissues.
Ripoll, G; Albertí, P; Joy, M
2012-02-01
One hundred and twenty-seven lambs were fed as follows: lambs and dams grazing alfalfa (Gr); the same as Gr but lambs had access to concentrate (Gr + S); ewes grazed and lambs received milk and concentrate until weaning and thereafter concentrate and straw (Rat-Gr); ewes and lambs were stall-fed (Ind). Lambs were slaughtered at 22-24 kg live weight and fat and M. rectus abdominis colour was measured instrumentally and subjectively. The evolution of the instrumental colour and texture of M. longissimus lumborum was also recorded. There were significant differences in the instrumental colour of subcutaneous fat amongst feeding systems, but no differences were observed upon visual appraisal. On average, M. rectus abdominis colour in the four feeding systems was classed as pink. Differences in longissimus thoracis colour at 0 h disappeared at 24h of air exposure and there were no differences in pH or cooking losses. At no time were any differences in instrumental texture found. Copyright © 2011 Elsevier Ltd. All rights reserved.
Intramuscular fatty acid composition of lambs fed diets containing alternative protein sources.
Scerra, M; Caparra, P; Foti, F; Cilione, C; Zappia, G; Motta, C; Scerra, V
2011-03-01
Thirty male Merinizzata italiana lambs were divided into three groups after weaning according to live weight. The diet of the three groups differed in the main protein source used in the concentrate, soybean meal for treatment SBM, faba bean for treatment FB and peas for treatment PEA. Lambs were fed ad libitum and slaughtered at about 160 days of age. Meat from the PEA group had higher proportions of the essential fatty acids C18:2 ω-6 and C18:3 ω-3 than from FB and SBM lambs and consequently its derivatives, C20:4 ω-6 and C20:5 ω-3 respectively, were higher in meat from PEA animals, compared to SBM and FB ones. The total n-3 fatty acids were highest in meat from PEA lambs and consequently PEA lambs showed a more favourable n-6/n-3 ratio. In conclusion the use of legume seeds such as peas in lamb diets positively affected intramuscular fatty acid composition. Copyright © 2010 The American Meat Science Association. Published by Elsevier Ltd. All rights reserved.
Aguayo-Ulloa, L A; Pascual-Alonso, M; Campo, M M; Olleta, J L; Villarroel, M; Pizarro, D M; Miranda-de la Lama, G C; María, G A
2014-08-01
We analysed the effect of enriched housing on the sensory meat quality and fatty acid composition of longissimus muscle in 60 entire Rasa Aragonesa lambs, housed indoors for 5 weeks in six pens (10 lambs/pen, 0.95 m(2)/lamb, initial weight 17.13±0.18 kg and carcass mean 12.23±0.23 kg); three control pens (barren) and three enriched pens (straw, platform with ramps and a small ramp). The final weight, carcass weight, fatness scores and cooking losses of meat from enriched lambs (EG) were higher and pH 24 was lower (P ≤ 0.05). The EG lambs had more C18:0 and total SFA (P ≤ 0.05). Lamb odour and grass odour were more intense in EG (P ≤ 0.05). Overall liking was higher for EG (P ≤ 0.05) and associated with tenderness (P ≤ 0.0001). The results suggest that environmental enrichment can have effects on fatty acid composition and sensory meat quality. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hoffman, L C; Muller, M; Cloete, S W P; Schmidt, D
2003-12-01
The effect of crossbreeding on lamb meat quality was examined on the M. longissimus dorsi and M. semimembranosus of South African lamb breed combinations. The lambs were sired by Dormer (D) and Suffolk (S) rams and born to Merino (M), Dohne Merino (DM) and SA Mutton Merino (SAMM) ewes to give six breed combinations. Ratings of sensory attributes on the M. semimembranosus of the different lamb breed combinations were obtained from a trained descriptive panel. The moisture, total lipids, protein, ash, mineral content and fatty acid composition of the M. semimembranosus were also obtained. Physical parameters measured on the M. longissimus dorsi were: pH(48), drip loss, cooking loss and Warner-Bratzler shear force (WBS). Breed did not have a significant effect (P>0.05) on the sensory quality of lamb, except for D×SAMM lambs which only showed a significantly higher (P⩽0.05) initial juiciness compared to S×M. However, breed had a significant effect on pH(48), WBS, protein content and the fatty acid and mineral composition.
The Productivity of Male Thin-Tailed Lambs and Sheep Fed Complete Feed
NASA Astrophysics Data System (ADS)
Aluns, M. S.; Luthfi, N.
2018-02-01
The aim of this study is to examine the productivity of thin tailed lambs and sheep fed complete feed. The material used in this study were 6 thin tailed lambs aged ± 5 months with an average body weight of 15.41 ± 2.11 kg (CV 37.04%) and 6 thin tailed rams aged ± 1 year with an average body weight of 23, 01 ± 1.91 kg (CV 28.83%). The animals were raised intensively with complete feed as much as 3.5% of body weight. The feed contained 12% crude protein (CP) and 55% Total Digestible Nutrients (TDNs). The results showed that the average feed intake was 567.10 g DMI/d in lambs and 726.24 g DMI per day in sheep. An average of body gain of lambs was 0.02 kg/d and 0.01 kg/d. The day matter digestibility of lambs achieves 50.23% and 50.74% in sheep. Based on results, it can be inferred that lambs has same digestibility with sheep and has more efficient to be fattened than sheep.
NASA Astrophysics Data System (ADS)
Gaydecki, P.
2009-07-01
A system is described for the design, downloading and execution of arbitrary functions, intended for use with acoustic and low-frequency ultrasonic transducers in condition monitoring and materials testing applications. The instrumentation comprises a software design tool and a powerful real-time digital signal processor unit, operating at 580 million multiplication-accumulations per second (MMACs). The embedded firmware employs both an established look-up table approach and a new function interpolation technique to generate the real-time signals with very high precision and flexibility. Using total harmonic distortion (THD) analysis, the purity of the waveforms have been compared with those generated using traditional analogue function generators; this analysis has confirmed that the new instrument has a consistently superior signal-to-noise ratio.
Method and Apparatus for Assessment of Changes in Intracranial Pressure
NASA Technical Reports Server (NTRS)
Yost, William T. (Inventor); Cantrell, John H. (Inventor)
2002-01-01
A non-invasive method and apparatus for monitoring changes in intracranial pressure which removes extracranial effects from the measurements. The method and apparatus can include the supplying of a fixed frequency electrical output to a transducer coupled to the patient's head, thereby generating an acoustical tone burst in the patient's head which generates a first echo and a second echo, the first echo reflecting from a first interface in the side of the patient's head coupled to the transducer, and the second echo reflecting from a second interface at the opposite side of the patient's head. The first and second echoes are received by the transducer which can generate a first electrical signal and a second electrical signal, wherein the first and second electrical signals vary in accordance with the corresponding first and second echoes. The counterbalancing phase shifts required to bring about quadrature between each of the first and second electrical signals and the fixed frequency electrical output can be measured, and values for the change in intracranial distance based on the changes in the counterbalancing phase shifts can be obtained.
Design of compact piezoelectric transducers for shock wave applications
NASA Astrophysics Data System (ADS)
Dreyer, Thomas; Liebler, Marko; Riedlinger, Rainer E.; Ginter, Siegfried
2003-10-01
The application of focused intense sound pulses to treat several orthopedic diseases has gained in importance during the past years. Self-focusing piezoelectric transducers known from ESWL are not well suited for this purpose due to their size. Therefore compact transducers have to be designed. This implies an increase of the pressure pulse amplitude generated at the radiating surface. A stacked placement of two piezoelectric layers driven by two high-voltage pulses with an adjustable delay accomplishes this. Several designs are presented here representing transducers of different sizes. In principle piezoelectric transducers have the ability to vary the pressure pulse shape to a wider extent than other shock wave sources. Based on FEM simulations of the transducer the influence of some driving parameters, like a variation of the interpulse delay or shape of the driving voltage, on the resulting focal pressure signal is demonstrated. The results show the feasibility to control some parameters of the signal, for example the peak negative pressure amplitude. This possibility could provide new aspects in basic research as well as in clinical applications.
Development of a directivity controlled piezoelectric transducer for sound reproduction
NASA Astrophysics Data System (ADS)
Bédard, Magella; Berry, Alain
2005-04-01
One of the inherent limitations of loudspeaker systems in audio reproduction is their inability to reproduce the possibly complex acoustic directivity patterns of real sound sources. For music reproduction for example, it may be desirable to separate diffuse field and direct sound components and project them with different directivity patterns. Because of their properties, poly (vinylidene fluoride) (PVDF) films offer lot of advantages for the development of electroacoustic transducers. A system of piezoelectric transducers made with PVDF that show a controllable directivity was developed. A cylindrical omnidirectional piezoelectric transducer is used to produce an ambient field, and a piezoelectric transducers system, consisting of a series of curved sources placed around a cylinder frame, is used to produce a sound field with a given directivity. To develop the system, a numerical model was generated with ANSYS Multiphysics TM8.1 and used to calculate the mechanical response of the piezoelectric transducer. The acoustic radiation of the driver was then computed using the Kirchoff-Helmoltz theorem. Numerical and experimental results of the mechanical and acoustical response of the system will be shown.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.116 Producer. Producer means any person who owns and produces lambs in the United States for sale. ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.102 Board. Board means the Lamb Promotion, Research, and Information Board established pursuant to § 1280.201. ...
7 CFR 1280.211 - Prohibited activities.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; and (c) Any advertising, including promotion, research, and information activities authorized to be... AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Lamb Promotion, Research, and Information...
Guided wave propagation in metallic and resin plates loaded with water on single surface
NASA Astrophysics Data System (ADS)
Hayashi, Takahiro; Inoue, Daisuke
2016-02-01
Our previous papers reported dispersion curves for leaky Lamb waves in a water-loaded plate and wave structures for several typical modes including quasi-Scholte waves [1,2]. The calculations were carried out with a semi-analytical finite element (SAFE) method developed for leaky Lamb waves. This study presents SAFE calculations for transient guided waves including time-domain waveforms and animations of wave propagation in metallic and resin water-loaded plates. The results show that non-dispersive and non-attenuated waves propagating along the interface between the fluid and the plate are expected for effective non-destructive evaluation of such fluid-loaded plates as storage tanks and transportation pipes. We calculated transient waves in both steel and polyvinyl chloride (PVC) plates loaded with water on a single side and input dynamic loading from a point source on the other water-free surface as typical examples of metallic and resin plates. For a steel plate, there exists a non-dispersive and non-attenuated mode, called the quasi-Scholte wave, having an almost identical phase velocity to that of water. The quasi-Scholte wave has superior generation efficiency in the low frequency range due to its broad energy distribution across the plate, whereas it is localized near the plate-water interface at higher frequencies. This means that it has superior detectability of inner defects. For a PVC plate, plural non-attenuated modes exist. One of the non-attenuated modes similar to the A0 mode of the Lamb wave in the form of a group velocity dispersion curve is promising for the non-destructive evaluation of the PVC plate because it provides prominent characteristics of generation efficiency and low dispersion.
Mousel, M R; Notter, D R; Leeds, T D; Zerby, H N; Moeller, S J; Taylor, J B; Lewis, G S
2014-07-01
Quality measures of lamb longissimus dorsi were evaluated in 514 crossbred wether lambs to assess sire breed differences. Wethers were produced over 3 yr from single-sire matings of 22 Columbia, 22 U.S. Meat Animal Research Center (USMARC)-Composite (Composite), 21 Suffolk, and 17 Texel rams to adult Rambouillet ewes. Lambs were reared to weaning in an extensive western rangeland production system and finished in a feedlot on a high-energy finishing diet. One of three harvest groups were randomly assigned to each lamb, and lambs were transported to The Ohio State University abattoir when the mean BW of wethers remaining in the feedlot reached 54.4, 61.2, or 68.0 kg. After harvest, subjective lean quality scores were assigned and LM pH (immediately after and 24 h after harvest), color (quantified as Minolta L*, a*, and b*), intramuscular fat (IMF), cooking loss percentage, and Warner-Bratzler shear force (WBSF) were determined. Statistical models included fixed effects of sire breed, year of birth, and harvest group and random effects of sire (nested within sire breed and year) and maternal grandsire. Year and harvest group were significant (P < 0.04) for all traits, except harvest group was not for WBSF and lean quality (P > 0.28). At comparable numbers of days on feed, Texel-sired wethers had the greatest (more desirable; P < 0.01) subjective lean quality scores while Composite- and Suffolk-sired lambs were intermediate and Columbia-sired lambs had the lowest (less desirable). Minolta L* values were greater (P < 0.02) for Texel- than Columbia-sired lambs, although this difference is not visually discernible by humans. No significant (P > 0.05) sire breed effects were detected for LM pH at or 24 h after harvest, Minolta a* and b*, IMF, percentage of cooking loss, and WBSF at comparable numbers of days on feed. At comparable chilled carcass weight, significant (P < 0.01) sire breed effects were detected for subjective lean quality score. Texel-sired lambs had greater scores than Columbia- and Suffolk-sired lambs, but Composite-sired lambs did not differ from lambs sired by the other sire breeds. Sire breed effects were not detected (P > 0.15) for LM pH at or 24 h after harvest, Minolta L*, a*, and b*, cooking loss percentage, IMF, and WBSF at comparable chilled carcass weight. Therefore, results of the present study indicated that the 4 sire breeds produced crossbred lamb carcasses that had similar and desirable LM quality measurements, meeting consumer expectations.
Acoustic cross-correlation flowmeter for solid-gas flow
Sheen, Shuh-Haw; Raptis, Apostolos C.
1986-01-01
Apparatus for measuring particle velocity in a solid-gas flow within a pipe includes: first and second transmitting transducers for transmitting first and second ultrasonic signals into the pipe at first and second locations, respectively, along the pipe; an acoustic decoupler, positioned between said first and second transmitting transducers, for acoustically isolating said first and second signals from one another; first and second detecting transducers for detecting said first and second signals and for generating first and second detected signals in response to said first and second detected signals; and means for cross-correlating said first and second output signals.
A digital transducer and digital microphone using an optical technique
NASA Astrophysics Data System (ADS)
Ghelmansarai, F. A.
1996-09-01
A transducer is devised to measure pressure, displacements or angles by optical means. This transducer delivers a digital output without relying on interferometry techniques or analogue-to-digital converters. This device is based on an optical scanner and an optical detector. An inter-digital photoconductive detector (IDPC) is employed that delivers a series of pulses, whose number depends on the scan length. A pre-objective scanning configuration is used that allows for the possibility of a flat image plane. The optical scanner provides scanning of IDPC and the generated scan length is proportional to the measurand.
Hynynen, Kullervo; Yin, Jianhua
2009-03-01
A method that uses lateral coupling to reduce the electrical impedance of small transducer elements in generating ultrasound waves was tested. Cylindrical, radially polled transducer elements were driven at their length resonance frequency. Computer simulation and experimental studies showed that the electrical impedance of the transducer element could be controlled by the cylinder wall thickness, while the operation frequency was determined by the cylinder length. Acoustic intensity (averaged over the cylinder diameter) over 10 W / cm(2) (a therapeutically relevant intensity) was measured from these elements.
Electrical potentials in bone induced by ultrasound irradiation in the megahertz range
NASA Astrophysics Data System (ADS)
Okino, M.; Coutelou, S.; Mizuno, K.; Yanagitani, T.; Matsukawa, M.
2013-09-01
Low frequency mechanical studies have reported the contribution of stress-induced electrical potentials to bone metabolism. However, the healing mechanism of bone fractures by low intensity ultrasound is not yet clear. We demonstrate that bone can generate electrical potentials by ultrasound irradiation in the MHz range. Electrical potentials were obtained from the output of bovine cortical bone transducers. In the range of 0.7-2.5 MHz, sensitivities of bone transducers were around 1/1000 of a poly (vinylidene fluoride) ultrasonic transducer and did not depend on magnitude and alignment of hydroxyapatite crystallites in bone.
Garcia, J C; Layton, S A; Rubal, B J
1989-05-01
This study compares the frequency response characteristics of catheter-mounted piezoelectric sound transducers with micromanometric transducers. The tip of a 8F catheter with two piezoelectric transducers and two micromanometers was inserted into a water-filled chamber that had a speaker fixed at one end. The speaker was driven by a power amplifier and sine wave generator. The outputs of the transducers were connected to a low-level amplifier. The piezoelectric transducer behaved as a tunable high-pass filter that could be modified by altering the input impedance of the low level amplifier; the frequency response characteristics were examined at five input impedances ranging from 0.96 to 11.8 megohms. The peak-to-peak outputs of the piezoelectric and pressure transducers were recorded at frequency ranges from DC to 1 kHz with a wide-band oscilloscope. The ratio of the outputs from the piezotransducer and micromanometer (Vph/Vpr) was plotted vs. frequency for each input impedance and analyzed to determine the piezotransducer's output resistance and equivalent capacitance; roll-off frequencies were then calculated. The equivalent capacitance of the piezo-element was determined to be 500-700 picofarads. Series capacitance acted with network resistance to produce a predictable frequency-dependent change in signal amplitude and phase angle. The inherent noise of the pressure transducer was found to be approximately 0.2 mm Hg, while the noise of the piezoelectric transducer was immeasurably low. The piezoelectric phonotransducers were superior to micromanometer transducers in their higher gain and lower noise, suggesting that these transducers may prove useful to physiologic and clinical studies for measuring intravascular sound.
Nagy, Peter B; Simonetti, Francesco; Instanes, Geir
2014-09-01
Recent improvements in tomographic reconstruction techniques generated a renewed interest in short-range ultrasonic guided wave inspection for real-time monitoring of internal corrosion and erosion in pipes and other plate-like structures. Emerging evidence suggests that in most cases the fundamental asymmetric A0 mode holds a distinct advantage over the earlier market leader fundamental symmetric S0 mode. Most existing A0 mode inspections operate at relatively low inspection frequencies where the mode is highly dispersive therefore very sensitive to variations in wall thickness. This paper examines the potential advantages of increasing the inspection frequency to the so-called constant group velocity (CGV) point where the group velocity remains essentially constant over a wide range of wall thickness variation, but the phase velocity is still dispersive enough to allow accurate wall thickness assessment from phase angle measurements. This paper shows that in the CGV region the crucial issue of temperature correction becomes especially simple, which is particularly beneficial when higher-order helical modes are also exploited for tomography. One disadvantage of working at such relatively high inspection frequency is that, as the slower A0 mode becomes faster and less dispersive, the competing faster S0 mode becomes slower and more dispersive. At higher inspection frequencies these modes cannot be separated any longer based on their vibration polarization only, which is mostly tangential for the S0 mode while mostly normal for the A0 at low frequencies, as the two modes become more similar as the frequency increases. Therefore, we propose a novel method for suppressing the unwanted S0 mode based on the Poisson effect of the material by optimizing the angle of inclination of the equivalent transduction force of the Electromagnetic Acoustic Transducers (EMATs) used for generation and detection purposes. Copyright © 2014 Elsevier B.V. All rights reserved.
Non-contact ultrasonic defect imaging in composites
NASA Astrophysics Data System (ADS)
Tenoudji, F. Cohen; Citerne, J. M.; Dutilleul, H.; Busquet, D.
2016-02-01
In the situations where conventional NDT ultrasonic techniques using immersion of the part under inspection or its contact with the transducers cannot be used, in-air investigation presents an alternative. The huge impedance mismatch between the part material and air (transmission loss in the order of 80 dB for a thin metallic plate) induces having to deal very small signals and unfavorable signal to noise ratios. The approach adopted here is the use of the crack of a spark generated by an induction coil as a sound source and an electrostatic polyethylene membrane microphone as a receiver [1]. The advantage of this source is that the spark power is high (several kilowatts) and its power is directly coupled to air during the energy release. In some difficult situations, an elliptical mirror is used to concentrate the sound beam power on the surface of the part [2,3]. Stability and reproducibility of the sound generated by the spark, which are a necessity in order to perform quantitative evaluations, are achieved in our experiment. This permits also an increase of the signal to noise ratio by signal accumulation. The sound pulse duration of few microseconds allows operating in pulse echo in some circumstances. The bandwidth of the source is large, of several hundred of kilohertz, and that of the microphone above 100 kHz allow the flexibility to address different kinds of materials. The technique allows an easy, in-air, non contact, inspection of structural composite parts, with pulse waves, with an excellent signal to noise ratio. An X-Y ultrasonic scanning ultrasonic system for material inspection using this technique has been realized. Results obtained in transmission and reflection are presented. Defects in carbon composite plates and in honeycomb are imaged in transmission Echographic measurements show that defect detection can be performed in thin plates using Lamb waves propagation when only one sided inspection of the part is possible.
Periconceptional growth hormone treatment alters fetal growth and development in lambs.
Koch, J M; Wilmoth, T A; Wilson, M E
2010-05-01
Research in the area of fetal programming has focused on intrauterine growth restriction. Few studies have attempted to examine programming mechanisms that ultimately lead to lambs with a greater potential for postnatal growth. We previously demonstrated that treatment of ewes with GH at the time of breeding led to an increase in birth weight. Therefore, the objective of this study was to determine the effects of a single injection of sustained-release GH given during the periconceptional period on fetal growth and development and to determine if the GH axis would be altered in these offspring. Estrus was synchronized using 2 injections of PGF(2alpha); at the time of the second injection, ewes assigned to treatment were also given an injection of sustained-release GH. A maternal jugular vein sample was taken weekly to analyze IGF-I as a proxy for GH to estimate the duration of the treatment effect. In ewes treated with GH, IGF-I increased (P < 0.05) by wk 1 and remained elevated until wk 4 postinjection. Lambs were weighed, crown-rump length and abdominal girth were determined, and a plasma sample was collected. In a subset of male lambs, liver, heart, and brain weights were obtained, as well as left and right ventricular wall thicknesses. On postnatal d 100, a subset of ewe lambs were weighed and challenged with an intravenous injection of GHRH. Lambs from treated ewes had increased (P < 0.05) birth weight and abdominal girth compared with control lambs; however, there was no difference in crown-rump length. Expression of GH receptor and IGF-I were increased (P < 0.05) in lambs gestated by GH-treated ewes compared with control ewes. The left ventricular wall was thinner (P < 0.05) from lambs in the GH-treated group compared with control lambs. On postnatal d 100, those ewe lambs born to ewes treated with GH continued to be heavier (P < 0.05) and had no IGF-I response to GHRH challenge. In conclusion, treating ewes with a single injection of GH appeared to alter fetal growth and development. Lambs born to ewes treated with GH were larger at birth and had altered organ development, which may indicate that early maternal GH treatment may lead to permanent changes in the developing fetus. The ewe lambs maintained their growth performance to at least 100 d of postnatal life and appeared to have an altered GH axis, as demonstrated by the altered response to GHRH.
Basso, F C; Adesogan, A T; Lara, E C; Rabelo, C H S; Berchielli, T T; Teixeira, I A M A; Siqueira, G R; Reis, R A
2014-12-01
This study aimed to examine the effects of feeding corn silage inoculated without or with either Lactobacillus buchneri (LB) alone or a combination of LB and Lactobacillus plantarum (LBLP) on the apparent digestibility, ruminal fermentation, microbial protein synthesis, and growth performance of lambs. Thirty Santa Inês×Dorper crossbred intact males lambs weighing 20.4±3.8 kg were blocked by weight into 10 groups. Lambs in each group were randomly assigned to 1 of the following 3 dietary treatments: untreated (Control), LB, and LBLP silage. Lambs were fed experimental diets for 61 d. The apparent digestibility was indirectly estimated from indigestible NDF measured on d 57 to 59. Spot urine samples were collected from all animals on d 59 to estimate microbial protein synthesis. Lambs were slaughtered for carcass evaluation on d 61 when they weighed 32.4±5.2 kg. Six additional ruminally cannulated Santa Inês×Dorper crossbred wethers weighing 40.5±1.8 kg were used to examine dietary effects on ruminal fermentation. Average daily gain was increased when lambs were fed LBLP silage (P<0.05) but not LB silage. The LBLP silage had the highest (P<0.05) lactic acid concentration and both inoculated silages had greater acetic acid concentrations than the Control silage (P<0.05). Inoculation of corn silage increased intakes of DM, OM, CP, NDF, total carbohydrate (CHO), and GE by the lambs but decreased digestibility of DM, OM, CP, total and nonstructural carbohydrates, and concentration of GE and ME. (P<0.05). Nevertheless, lambs fed inoculated silages had greater microbial N supply than those on the Control treatment (P<0.05). The acetate to propionate ratio was lower in ruminal fluid of wethers in LBLP treatment than LB and Control treatment (P<0.05) and ruminal pH tended to be greater in LB lambs than in LBLP and Control wethers (P<0.10). Finally, the inoculation with both bacteria combined enhanced the silage fermentation. The intakes of DM, OM, CP, NDF, and GE were improved in the lambs fed corn silage inoculated with L. buchneri alone or combined with L. plantarum. The microbial N supply was enhanced in the lambs fed corn silage inoculated with L. buchneri. The inoculation of L. buchneri combined with L. plantarum reduced the acetate to propionate ratio in ruminal fluid and improved the ADG of lambs.
Stable isotope ratio analysis for authentication of lamb meat.
Piasentier, E; Valusso, R; Camin, F; Versini, G
2003-07-01
The effectiveness of the analysis of stable isotope ratios ((13)C/(12)C and (15)N/(14)N) in fractions of lamb meat, measured by isotope ratio mass spectrometry, was evaluated as a method of feeding and geographical origin authentication. Analyses were carried out on meat from 12 lamb types, produced in couples in six European countries (country of origin, CO) and divided in three groups according to the feeding regime during their finishing period: suckled milk only, pasture without any solid supplementation and supplementation containing maize grain (feeding regime, FR). These analyses were made on two samples of longissimus thoracis muscle, taken from the 13th rib section of the left side of two different lambs, randomly chosen between the 120 selected to represent each lamb type. δ(13)C values varied significantly in different meat fractions, the difference being higher in protein than in fat (average difference 5.0‰). However, the pairs δ(13)C values of crude fat and protein were highly correlated (r=0.976) and affected by lamb type in a similar fashion, mainly reflecting animals' feeding regime. Even δ(15)N values of meat protein fraction showed significant differences between lamb types, not dependant on the feeding regime. In fact, lambs fed on similar diets, but in different countries, gave meat with different (15)N relative abundances. These findings provide the possibility of discriminating lamb types within the same feeding regime. Canonical discriminant analysis was carried out to evaluate whether lamb meat from different CO or FR or CO×FR interaction could be mathematically distinguished by its stable isotope ratios. On the basis of CO, the corrected empirical allocation of 79.2% of the initial observations and the corrected cross-validation of two thirds of the individual meat samples was obtained. FR gave better results: 91.7% of the individual meat samples was both correctly allocated and cross-validated, indicating the high potential of stable isotope ratio analysis as a tool for lamb diet characterisation. The most satisfactory classification attained, using K-means clustering technique and canonical discriminant analysis, enabled a good resolution of six CO×FR groups of lamb types: Icelandic fed on pasture; British and French grazing; Italian; suckled and Karagouniko concentrates finished; French Lacaune; Ternasco de Aragon. It was concluded that multielement stable isotope analysis may be considered promising for the reliable evaluation of lamb meat authenticity, in the same way as for wine, fruit juice, honey and dairy products.
Polwarth and Texel ewe parturition duration and its association with lamb birth asphyxia.
Dutra, F; Banchero, G
2011-10-01
The objective of the present study was to test the hypothesis that parturition duration is related to birth asphyxia in lambs and that asphyxia affects newborn lamb viability and vigor. Two sire and dam genotypes (Texel: TX; Polwarth: PW) and their crosses were represented in the study. Eighty lambs (25 PW sire × PW dam, 13 TX × TX, 25 TX × PW, and 17 PW × TX) born to 69 grazing ewes were used. At birth, the log₁₀ length of the second stage of parturition, birth weight, placental weight, and several body measurements were recorded on all lambs, and jugular blood samples were analyzed with the i-Stat Portable Clinical Analyzer (Abbott, Montevideo, Uruguay). A modified Apgar viability score at birth and lamb behavior during their first hour of life were recorded. Brain weight, muscle:bone ratio, and bone density were recorded in 20 male lambs (5 from each breed group) that were euthanized and dissected 24 h after birth. Data were analyzed by linear regression, least squares ANOVA, and ordinal and binary logistic regressions. Mean blood gas and acid-base variables were 7.21 ± 0.09 for pH, 18.4 ± 9.8 mmHg for partial pressure of oxygen, 53 ± 12.5 mmHg for partial pressure of carbon dioxide, and -4 ± 5.1 mmol/L for extracellular fluid base excess. Parturition duration increased with birth weight (P < 0.001) and was shorter in TX ewes (P < 0.001), female lambs (P < 0.05), twins (P < 0.09), and twin females (sex × litter size interaction, P < 0.02). Twenty-six (32.9%) lambs were born asphyxiated (pO₂ < 10 mmHg or pH <7.1). Parturition duration increased the risk of asphyxia (P < 0.001), decreased the viability score (P < 0.001), and increased the latency to suckle the udder (P < 0.05). Twin-born lambs presented at birth a 16-fold greater risk of asphyxia (P < 0.01) and reduced placental efficiency (P < 0.05). Texel-sired lambs appeared immature at birth, with less bone density (P < 0.05), smaller brain (P < 0.05), shorter forelimbs (P < 0.05), greater anterior (P < 0.001) and posterior (P < 0.05) neck circumference, and greater muscle:bone ratio (P < 0.05). Immaturity may explain greater TX biotype survival. Together these results demonstrate that a relationship exists between parturition duration, neonatal viability and behavior, and acid-base balance values in single- and twin-born lambs, suggesting that birth asphyxia is an important risk factor in perinatal lamb mortality.
Index selection in terminal sires improves lamb performance at finishing.
Márquez, G C; Haresign, W; Davies, M H; Roehe, R; Bünger, L; Simm, G; Lewis, R M
2013-01-01
Lamb meat is often perceived by consumers as fatty, and consumption has decreased in recent decades. A lean growth index was developed in the UK for terminal sire breeds to increase carcass lean content and constrain fat content at a constant age end point. The purposes of this study were 1) to evaluate the effects of index selection of terminal sires on their crossbred offspring at finishing and 2) to evaluate its effectiveness within terminal sire breeds. Approximately 70% of lambs marketed in the UK have been sired by rams of breeds typically thought of as specialized terminal sires. The most widely used are Charollais, Suffolk, and Texel. These breeds participated in sire referencing schemes from the early 1990s by sharing rams among flocks selected on the lean growth index. From 1999 to 2002 approximately 15 "high" and 15 "low" lean growth index score rams were selected from within their sire referencing schemes and mated to Welsh and Scottish Mule ewes. Their crossbred offspring were commercially reared on 3 farms in the UK. Lambs were finished to an estimated 11% subcutaneous fat by visual evaluation. At finishing, lambs were weighed, ultrasonically scanned, and assessed for condition score and conformation. Records were obtained for 6356 lambs on finishing BW (FWT), ultrasonic muscle depth (UMD), ultrasonic fat depth, overall condition score (OCS), and conformation of gigot, loin, and shoulder. Ultrasonic fat depth was log transformed (logUFD) to approach normality. High-index-sired lambs were heavier at finishing (1.2±0.2 kg) with thicker UMD (0.7±0.2 mm) and less logUFD (0.08±0.01 mm; P<0.05). There were no differences in OCS or conformation based on the sire index or breed (P>0.08). Suffolk-sired lambs were heavier than Charollais (1.0±0.3 kg), which were heavier than Texel (0.9±0.3 kg; P<0.001). Texel-sired lambs had thicker UMD than Charollais (0.7±0.2 mm; P<0.001) but were not different than Suffolk. Charollais-sired lambs had greater logUFD than both Texel (0.098±0.016 mm) and Suffolk (0.061±0.017 mm) sired lambs (P<0.001). Within a breed, high- and low-index-sired lambs differed in performance with the exceptions of FWT and UMD in Suffolks. Index selection produced heavier and leaner lambs at finishing. Producers have flexibility in choosing the terminal sire that best fits their production system.
Bonanno, A; Di Miceli, G; Di Grigoli, A; Frenda, A S; Tornambè, G; Giambalvo, D; Amato, G
2011-01-01
The nutritional effects of sulla (Hedysarum coronarium L.) forage containing condensed tannins (CT) on growth of lambs, and carcass and meat quality were investigated. Thirty-two male Comisana lambs aged 100 ± 8 days weighing 19.0 ± 2.8 kg were fed fresh forage of sulla or CT-free annual ryegrass (Lolium multiflorum Lam. subsp. Wersterwoldicum) for 49 days until slaughter; in addition, each lamb was supplied with 200 g/days of concentrate. Eight lambs per diet had been previously treated with anthelmintic drugs to remove nematode parasites. Measurements of BW and feed intake, and counts of faecal nematode eggs were made. Carcass parameters were recorded after slaughter, and tissue components of the hind leg were determined. Longissimus dorsi meat was evaluated for pH, colour, thawing and cooking losses, Warner-Bratzler shear force, chemical composition and sensory properties based on triangle tests. Relative to ryegrass-fed lambs, sulla-fed lambs had significantly greater dry matter (DM) and protein intake, a more favourable feed conversion ratio, and superior growth rate, final BW at 150 days of age, carcass weight, yield and fatness. These results were attributed to the high protein and non-structural carbohydrate content of sulla, and also to the moderate CT content of sulla (16.7 and 20.3 g/kg of DM in offered and consumed sulla forage, respectively). Anthelmintic treatment did not affect lamb growth, as the level of parasitic infection (initial and final) was low. The physical, chemical and sensory properties of the lamb meat were not influenced by diet.
Simulation of transducer-couplant effects on broadband ultrasonic signals
NASA Technical Reports Server (NTRS)
Vary, A.
1980-01-01
The increasing use of broadband, pulse-echo ultrasonics in nondestructive evaluation of flaws and material properties has generated a need for improved understanding of the way signals are modified by coupled and bonded thin-layer interfaces associated with transducers. This understanding is most important when using frequency spectrum analyses for characterizing material properties. In this type of application, signals emanating from material specimens can be strongly influenced by couplant and bond-layers in the acoustic path. Computer synthesized waveforms were used to simulate a range of interface conditions encountered in ultrasonic transducer systems operating in the 20 to 80 MHz regime. The adverse effects of thin-layer multiple reflections associated with various acoustic impedance conditions are demonstrated. The information presented is relevant to ultrasonic transducer design, specimen preparation, and couplant selection.
Smith, Richard W.
1979-01-01
An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.
Apparatus and method for prevention of cracking in welded brittle alloys
Kronberg, James W.; Younkins, Robert M.
2000-01-01
An apparatus and method for reducing cracking in a heated material as the material cools. The apparatus includes a variable frequency electric signal generator that is coupled to a transducer. The transducer produces a variable frequency acoustic signal in response to the variable frequency electric signal, which is applied to the heated material to reduce cracking as the material cools.
NASA Technical Reports Server (NTRS)
Peterson, Thomas M.
2001-01-01
The next series of planetary exploration missions require a method of extracting rock and soil core samples. Therefore a prototype ultrasonic core driller (UTCD) was developed to meet the constraints of Small Bodies Exploration and Mars Sample Return Missions. The constraints in the design are size, weight, power, and axial loading. The ultrasonic transducer requires a relatively low axial load, which is one of the reasons this technology was chosen. The ultrasonic generator breadboard section can be contained within the 5x5x3 limits and weighs less than two pounds. Based on results attained the objectives for the first phase were achieved. A number of transducer probes were made and tested. One version only drills, and the other will actually provide a small core from a rock. Because of a more efficient transducer/probe, it will run at very low power (less than 5 Watts) and still drill/core. The prototype generator was built to allow for variation of all the performance-effecting elements of the transducer/probe/end effector, i.e., pulse, duty cycle, frequency, etc. The heart of the circuitry is what will be converted to a surface mounted board for the next phase, after all the parameters have been optimized and the microprocessor feedback can be installed.
7 CFR 1280.235 - Proceedings after termination.
Code of Federal Regulations, 2010 CFR
2010-01-01
... SERVICE (MARKETING AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Miscellaneous... be utilized, to the extent practicable, in the interest of continuing one or more of the lamb...
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Miscellaneous § 1280.233 Referenda. (a... determined by the Secretary, have engaged in the production, feeding, handling, or slaughter of lamb; or the...
Li, Fei; Wang, Zhilan; Dong, Chunxiao; Li, Fadi; Wang, Weimin; Yuan, Zehu; Mo, Futao; Weng, Xiuxiu
2017-01-01
Several ruminal cellulolytic bacteria species are sensitive to pH and could therefore be used as biomarkers to determine the risk of sub-acute ruminal acidosis (SARA) in finishing lambs. This study compared a 2–4 h post feeding ruminal pH measurement to abundances of the ruminal pH-sensitive bacteria to evaluate the risk of SARA in a herd of 120 finishing lambs. The lambs were reared in individual units for 50 days. Ruminal fluid was collected by use of an orogastric tube on day 51 2-4 h after feeding. Although the lambs were fed an identical diet, they responded differently in the abundances of four ruminal pH sensitive cellulolytic bacteria (Ruminococcus albus, Ruminococcus flavefaciens and Fibrobacter succinogenes and Butyrivibrio fibrisolvens). Lambs with the most or the least cellulolytic bacteria were then classified as either lower SARA risk (LSR, n = 10) or higher SARA risk group (HSR, n = 10), respectively. Data showed that the ruminal pH and VFA profiles were uncorrelated with the number of cellulolytic bacteria (P > 0.050). Lambs with the HSR showed lower ruminal pH (P = 0.013) and acetate to propionate ratio (P = 0.018), higher concentrations of lactate (P = 0.035) and proportion of propionate (P = 0.033) compared to those with the LSR. The DMI and ADG did not differ in LSR and HSR lambs (P > 0.050). A diversity analysis revealed significantly lower diversity in HSR lambs than in LSR (Simpson index, P = 0.004). The relative abundances of the phyla Bacteroidetes, Fibrobacteres, Verruomicrobia, and Proteobacteria were higher in LSR lambs than in HSR (P < 0.050). The abundances of several phyla including Firmicutes, Tenericutes and Actinobacteria were higher in the HSR than in the LSR group (P < 0.050). The bacterial communities of the LSR and HSR clustered separately in rumen based on the Unifrac distances, indicating distinct bacteria communities at OTU level between the LSR and HSR lambs. Overall, there was no correlation between 2 and 4 h post-feeding ruminal pH and the abundance of pH-sensitive bacteria and the amount of these bacteria could be used as a potential biomarker of SARA in lamb herd. PMID:29312208
Sterndale, S; Broomfield, S; Currie, A; Hancock, S; Kearney, G A; Lei, J; Liu, S; Lockwood, A; Scanlan, V; Smith, G; Thompson, A N
2018-05-01
Vitamin E and selenium have been reported to improve immune function across a range of species. Ewes lambing on poor-quality dry pasture in autumn in Western Australia are at risk of being deficient in vitamin E and selenium at lambing thus predisposing their lambs to deficiencies and increasing the risk of infection and disease. This study tested the hypotheses that (i) supplementation of autumn-lambing ewes with vitamin E plus selenium in late gestation will increase the concentrations of vitamin E and selenium in plasma in the ewe and lamb and (ii) that the increased concentrations of vitamin E and selenium in plasma in the lambs will improve their innate and adaptive immune responses and thus survival. Pregnant Merino ewes were divided into a control group (n=58) which received no supplementation or a group supplemented with vitamin E plus selenium (n=55). On days 111, 125 and 140 of pregnancy ewes in the vitamin E plus selenium group were given 4 g all-rac-α-tocopherol acetate orally. On day 111 the ewes were also given 60 mg of selenium as barium selenate by subcutaneous injection. The concentrations of α-tocopherol and selenium were measured in ewes and/or lambs from day 111 of pregnancy to 14 weeks of age±10 days (weaning). Immune function of the lamb was assessed by analysing the numbers and phagocytic capacities of monocytes and polymorphonuclear leucocytes and plasma IgG and anti-tetanus toxoid antibody concentrations between birth and 14 weeks of age±10 days. Maternal supplementation with vitamin E plus selenium increased the concentration of α-tocopherol in plasma (1.13 v. 0.67 mg/l; P<0.001) and selenium in whole blood (0.12 v. 0.07 mg/l; P<0.01) of the ewes at lambing compared with controls. Supplementation also increased the concentration of α-tocopherol (0.14 v. 0.08 mg/l; P<0.001) and selenium (0.08 v. 0.05 mg/l; P<0.01) in lambs at birth compared with controls. There was no significant effect of supplementation on immune function or survival in the lambs.
Taheri, Mohammad Reza; Zamiri, Mohammad Javad; Rowghani, Ebrahim; Akhlaghi, Amir
2013-01-01
Feed cost has a significant effect on the economic efficiency of feedlot lambs; therefore, the use of low-cost non-conventional feedstuffs, such as olive pulp (OP), has the potential to decrease the production costs. Because optimum inclusion of OP-treated silages has not been determined in feedlot lambs, an experiment was conducted to determine the effect of inclusion of OP ensiled with additives in the diet on the feedlot performance and carcass attributes of feedlot lambs. Ram lambs of Mehraban and Ghezel breeds (n = 50 lambs per breed) were randomly allotted to 10 groups and fed with one of the nine diets containing OP silage or a control diet. Silage treatments were: (1) OP silage without additives (OPS), (2) OP ensiled with 8 % beet molasses and 0.4 % formic acid (OP-MF), and (3) OP ensiled with 8 % beet molasses, 0.4 % formic acid and 0.5 % urea (OP-MFU). The control diet contained 50 % alfalfa hay and 50 % barley grain. Three levels from each silage were chosen to replace the barley grain (10, 20, or 30 % dry matter basis). The lambs were slaughtered after 92 days, and the average daily gain (ADG), feed conversion ratio (FCR), and carcass characteristics were determined. Feeding OPS to fat-tailed lambs, at an inclusion level of 30 %, decreased the carcass dressing percentage, mainly as a result of decreased brisket percentage, but the ADG and FCR values were not adversely affected. Ghezel lambs had higher ADG than Mehraban lambs, but the visceral fat weight percentage, flap weight percentage, and back fat depth were higher in Mehraban. The crude protein content in the longissimus dorsi (LD) muscle was higher in Ghezel, but the dry matter percentage was higher in Mehraban (P < 0.05). Other attributes were not significantly affected by breed (P > 0.05). Most carcass characteristics, including major cuts, were not affected by OPS feeding; therefore, feeding OPS (up to 30 %) can be economical for feedlot lambs. Most carcass characteristics, including major cuts, were not affected by OPS levels used in this experiment; therefore, inclusion of OPS (up to 30 %) in the diet may reduce the cost of raising feedlot lambs. This also could help alleviate the problem of storage of OP in oil factories.
A Measurement Method for the Power Generation Characteristics of Piezoelectric Elements
NASA Astrophysics Data System (ADS)
Ichiki, Masaaki; Maeda, Ryutaro; Kitahara, Tokio
The electrical and mechanical properties of piezoelectrics for power generation in wearable electronic devices were measured using an experimental apparatus. With a 40 N applied load, the peak output power of PZT system transducers was measured at 3 μW, comprising 1.8 V and 1.7 μA. The electro-mechanical coupling constant was measured at 0.53 using PZT in the same apparatus in short- and open-circuit conditions. It is possible to harness mW power by installing piezoelectric transducers on the soles of footwear, where the total weight of a human is applied most efficiently.
USDA-ARS?s Scientific Manuscript database
Pneumonia is a population-limiting disease of bighorn sheep (BHS; Ovis canadensis) and a recognized disease entity in domestic sheep (DS; Ovis aries) worldwide. Respiratory disease in BHS lambs can persist for years after all-age outbreaks, resulting in suppressed lamb recruitment. It has been sugge...
Role of carriers in the transmission of pneumonia in bighorn sheep (Ovis canadensis)
Raghavan, Bindu; Erickson, Kayla; Kugadas, Abirami; Batra, Sai A.; Call, Douglas R.; Davis, Margaret A.; Foreyt, William J.
2016-01-01
ABSTRACT In the absence of livestock contact, recurring lamb mortality in bighorn sheep (Ovis canadensis) populations previously exposed to pneumonia indicates the likely presence of carriers of pneumonia-causing pathogens, and possibly inadequate maternally derived immunity. To investigate this problem we commingled naïve, pregnant ewes (n=3) with previously exposed rams (n=2). Post-commingling, all ewes and lambs born to them acquired pneumonia-causing pathogens (leukotoxin-producing Pasteurellaceae and Mycoplasma ovipneumoniae), with subsequent lamb mortality between 4-9 weeks of age. Infected ewes became carriers for two subsequent years and lambs born to them succumbed to pneumonia. In another experiment, we attempted to suppress the carriage of leukotoxin-producing Pasteurellaceae by administering an antibiotic to carrier ewes, and evaluated lamb survival. Lambs born to both treatment and control ewes (n=4 each) acquired pneumonia and died. Antibody titers against leukotoxin-producing Pasteurellaceae in all eight ewes were ‘protective’ (>1:800 and no apparent respiratory disease); however their lambs were either born with comparatively low titers, or with high (but non-protective) titers that declined rapidly within 2-8 weeks of age, rendering them susceptible to fatal disease. Thus, exposure to pneumonia-causing pathogens from carrier ewes, and inadequate titers of maternally derived protective antibodies, are likely to render bighorn lambs susceptible to fatal pneumonia. PMID:27185269
A novel mutation of laminin β2 (LAMB2) in two siblings with renal failure.
Falix, Farah A; Bennebroek, Carlien A M; van der Zwaag, Bert; Lapid-Gortzak, Ruth; Florquin, Sandrine; Oosterveld, Michiel J S
2017-04-01
This report describes a novel mutation of LAMB2, the gene associated with Pierson syndrome (microcoria-congenital nephrosis syndrome), in two female siblings. The c.970T>C p.(Cys324Arg) mutation in the LAMB2 gene affects one of the eight highly conserved cysteine residues within the first EGF-like module of the laminin β2 protein. These residues form disulfide bonds in order to achieve a correct 3D structure of the protein. The reported phenotype is considered a relatively mild variant of Pierson syndrome and is associated with later-onset (18 months) therapy-resistant nephrotic syndrome leading to renal failure, and ocular abnormalities consisting of high myopia, microcoria, diverse retinal abnormalities, hence a low level of visual acuity. Importantly, the reported LAMB2 mutation was associated with normal neurological development in both siblings. this report presents the variability of the renal, ocular and neurological phenotypes associated with LAMB2 mutations and underscores the importance of ophthalmologic examination in all children with unexplained renal insufficiency or nephrotic syndrome. What is known • LAMB2 mutations are associated with Pierson syndrome • Pierson syndrome is associated with congenital nephrotic syndrome, microcoria and neurological deficits What is new • A novel mutation in the LAMB2 gene in two female siblings • Genotype and clinical phenotype description of a novel LAMB2 mutation.
Effects of road type during transport on lamb welfare and meat quality in dry hot climates.
Miranda-de la Lama, Genaro C; Monge, Paula; Villarroel, Morris; Olleta, Jose Luis; García-Belenguer, Sylvia; María, Gustavo A
2011-06-01
This study determined whether transporting lambs on paved (PR) or unpaved roads (UR) for 3 h had an effect on plasma stress indicators (cortisol, lactate, glucose, creatine kinase [CK], red blood cells, white blood cells, hematocrit, and neutrophil/lymphocyte [N/L] ratio) and instrumental meat quality (pH24, bruising score, water holding capacity [WHC], color, and texture). A total of 48 Rasa Aragonesa male lambs were used that were approximately 100 days old (12.5 kg ± 1.64, carcass weight). The results suggest that transport on unpaved roads had a significant influence on physiological and hematological stress parameters. Road type had a significant effect on all variables, except for white and red blood cells, and hematocrit levels. The UR lambs had significantly higher (at least p ≤ 0.01) cortisol, lactate, glucose, and CK levels and a higher N/L ratio than PR lambs. Meat from UR lambs had some dark-cutting characteristics, with a darker color, higher ultimate pH, and higher tenderness values than PR. In conclusion, lambs transported on unpaved roads had a more intense stress response and poorer meat quality than lambs transported on paved roads. An effort to improve the logistics associated with route planning is necessary to prevent welfare problems during transport to slaughter.
Effect of legume grains as a source of dietary protein on the quality of organic lamb meat.
Bonanno, Adriana; Tornambè, Gabriele; Di Grigoli, Antonino; Genna, Vincenzo; Bellina, Vincenzo; Di Miceli, Giuseppe; Giambalvo, Dario
2012-11-01
This study evaluated the effects on lamb growth, carcass traits and meat quality of replacing conventional soybean meal in the diet with alternative legume grains. Twenty-eight male lambs of Comisana breed weighing 16.9 ± 2.7 kg at weaning (66 ± 6 days old) were assigned to one of four diets. Until slaughter at 129 ± 6 days of age, each group received ad libitum pelleted alfalfa hay and concentrates differing in the source of protein: chickpea, faba bean, pea or soybean meal. Lambs fed chickpea showed higher dry matter and protein intakes from concentrate than those fed soybean. Lambs' growth, carcass weight and net dressing percentage did not vary by protein source, although chickpea lambs had more perirenal and pelvic fat than those in the soybean group. Diet did not affect chemical composition, colour, thawing and cooking losses, tenderness, and sensory properties of meat. Chickpea increased trans-vaccenic and linoleic acid, and chickpea and faba bean increased the isomers of conjugated linoleic acid. Legume grains can completely replace soybean meal in concentrate, resulting in lamb carcasses and meat of comparable quality. Chickpea leads to an increase in feed intake of lambs and in fat depots in the carcass, and a more beneficial fatty acid profile. Copyright © 2012 Society of Chemical Industry.
Effect of muscle type, salt and pH on cooked meat haemoprotein formation in lamb and beef.
Lytras, G N; Geileskey, A; King, R D; Ledward, D A
1999-06-01
The rate of cooked meat haemoprotein formation, measured as the rate of loss of myoglobin solubility, in lamb was dependent on the muscles anatomical location and temperature. Lamb longissimus dorsi musle at 55 to 70°C formed cooked meat haemoprotein more rapidly than the muscles in the shoulder and leg. The formation in lamb was more rapid than in beef. The rate in high pH beef (7.25) l. dorsi was lower than found in beef l. dorsi of normal pH but in low pH lamb (5.38) l. dorsi the rate was, at most temperatures, also slower than found in this muscle from lamb of normal pH. In the presence of NaCl the rate of cooked meat haemoprotein formation was faster (almost doubled at 2g/100g meat) than found in the corresponding salt free lamb and beef samples. Other additives commonly added to meat products (mechanically recovered meat, oil, polyphosphates, soya, whey and caseinate) had little effect on the rate of cooked meat haemoprotein formation, at the levels normally used in meat products. It is concluded that for lamb products little if any myoglobin will remain soluble, and the products will look cooked before the recommended thermal treatment to inactivate Escherichia coli O157:H7 has been achieved. ©
Oocyte pick-up in juvenile lambs affects neither onset of puberty nor their future fertility.
Valasi, Irene; Menegatos, I; Papanikolaou, Th; Goulas, P; Amiridis, G S
2006-12-01
A study was designed to evaluate whether the time of onset of puberty and fertility of young ewe lambs would be affected by oocyte pick-up conducted in single or repeated sessions during the first months of lambs' live. Five groups of lambs from the Karagouniko breed were used (A-E each n=12). In group A no treatments were applied (control group) while, laparoscopical follicular aspiration (OPU) was performed early in the third, fourth and fifth month of lambs age (groups C-E, respectively). From the second to fifth month of their age, group B lambs were aspirated four times in monthly intervals. All lambs were weighed at birth, weaning, at second month and monthly thereafter until the eighth month of age. Progesterone priming and ovarian stimulation by serial FSH administrations proceeded each OPU session. To determine onset of puberty blood progesterone concentration was assayed in samples collected initially every week and after the seventh month of age twice weekly. From the seventh month a fertile ram was introduced in each group and oestrous behavior/mating was daily monitored and recorded. Pregnancy diagnosis was carried out by transabdominal ultrasound scanning 55 days after rams' removal. At the fourth and fifth month of age group B lambs were lighter (p<0.05) than controls, but this difference was later equalized. The time of onset of puberty did not differ between groups (p=0.069) and ranged between 224 and 270 days. Some animals (n=15) entered puberty with a full-length luteal phase having progesterone concentration greater than 1ng/ml, while others (n=32) exhibited one or two short luteal phases before luteal length restoration. During the first breeding season 41 animals were fertilized and maintained pregnancy to term, without noticeable differences between groups (p=0.555). During the second breeding season, all ewes were naturally served and lambed at the expected time. It is concluded that OPU in young dairy lambs does not affect the time of onset of puberty, the endocrine profile of the lambs and it does not compromise their future fertility even if it is applied at four successive months.
Device and method for generating a beam of acoustic energy from a borehole, and applications thereof
Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian; Nihei, Kurt; Schmitt, Denis P.; Skelt, Christopher
2010-11-23
In some aspects of the invention, a device, positioned within a well bore, configured to generate and direct an acoustic beam into a rock formation around a borehole is disclosed. The device comprises a source configured to generate a first signal at a first frequency and a second signal at a second frequency; a transducer configured to receive the generated first and the second signals and produce acoustic waves at the first frequency and the second frequency; and a non-linear material, coupled to the transducer, configured to generate a collimated beam with a frequency equal to the difference between the first frequency and the second frequency by a non-linear mixing process, wherein the non-linear material includes one or more of a mixture of liquids, a solid, a granular material, embedded microspheres, or an emulsion.
Piezoelectric diaphragm for vibration energy harvesting.
Minazara, E; Vasic, D; Costa, F; Poulin, G
2006-12-22
This paper presents a technique of electric energy generation using a mechanically excited unimorph piezoelectric membrane transducer. The electrical characteristics of the piezoelectric power generator are investigated under dynamic conditions. The electromechanical model of the generator is presented and used to predict its electrical performances. The experiments was performed with a piezoelectric actuator (shaker) moving a macroscopic 25 mm diameter piezoelectric membrane. A power of 0.65 mW was generated at the resonance frequency (1.71 kHz) across a 5.6 kOmega optimal resistor and for a 80 N force. A special electronic circuit has been conceived in order to increase the power harvested by the piezoelectric transducer. This electrical converter applies the SSHI (synchronized switch harvesting on inductor) technique, and leads to remarkable results: under the same actuation conditions the generated power reaches 1.7 mW, which is sufficient to supply a large range of low consumption sensors.
7 CFR 1280.114 - Part and subpart.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AGREEMENTS AND ORDERS; MISCELLANEOUS COMMODITIES), DEPARTMENT OF AGRICULTURE LAMB PROMOTION, RESEARCH, AND INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.114 Part and subpart. Part means the Lamb Promotion, Research, and Information Order and all rules and regulations issued...
Sagkan-Ozturk, A; Durgut, R; Ozturk, O H
2015-03-15
The aim of this study was to evaluate total antioxidant capacity (TAC), total oxidant status (TOS), and oxidative stress index (OSI) in sheep and lambs with cyctic eccinocoocosis (CE) diagnosed by ultrasonography and necropsy findings. A total of 9 sheep and 17 lambs with CE were used in this study and the findings were compared to those of 6 healthy control sheep. Ultrasonography were used for the diagnosis of CE in sheep and lambs, and necropsy was performed to check the presence of cysts in liver and lungs. Serum TOS and TAC were measured by a novel colorimetric method. The TOS-to-TAC ratios were also calculated as OSI values. Serum biochemical profiles were determined by conventional measurement methods as well. The mean values for TOS, TAC and OSI were significantly (p<0.001) lower in sheep and lambs with CE when compared with those of the control sheep, and they were also significantly lower in lambs with CE in comparison to the mean values obtained in sheep with CE. The levels of serum albumin, total cholesterol, creatinine, and triglycerides in lambs with CE were found out to decrease significantly (p<0.001) when compared with those of both sheep with EC and the control group. There were no significant differences between the groups in terms of other serum parameters. In addition, when clinically and some biochemical values were evaluated, CE was found to be more severe in lambs than in sheep. It was concluded that although common diagnostic cyst detection is performed by postmortem examination, ultrasonography could successfully be used in conjunction with serum biochemical profile detection and serum TOS, TAC and OSI measurements for diagnosis of cysts in liver and lungs of severely infected living sheep and lambs. Serum albumin, total cholesterol, creatinine, total protein and triglycerides might be used as indicators in sheep and particularly in lambs for the diagnosis of CE. Copyright © 2015 Elsevier B.V. All rights reserved.