Sample records for transfer agent cta

  1. Effect of the different chain transfer agents on molecular weight and optical properties of poly(methyl methacrylate)

    NASA Astrophysics Data System (ADS)

    Çetinkaya, Onur; Demirci, Gökhan; Mergo, Paweł

    2017-08-01

    Investigation of molecular weight and optical properties of poly(methyl metacrylate) (PMMA) polymerized in house with different chain transfer agents was studied. Isopropyl alcohol (IPA), n-butyl mercaptan (nBMC) and pentamethyl disilane (PMDS) were used as chain transfer agents. The molecular weight (Mw) of PMMA samples were measured by Ostwald viscometer. Mw of bulk polymer samples were decreased with increase the concentration of chain transfer agents (CTA). Since reactivity of used CTAs is not same, molecular weights of samples which were produced with different type of CTA but same concentration of CTA was varied. Higher concentration of n-BMC showed higher scattering. Transmission of samples could not be correlated with different concentration of CTA. Refractive index of samples was not affected by concentration of CTA nevertheless higher molecular weight of CTA showed higher refractive index.

  2. Retraction Note: Catalytic living ring-opening metathesis polymerization

    NASA Astrophysics Data System (ADS)

    Nagarkar, Amit A.; Kilbinger, Andreas F. M.

    2018-05-01

    We the authors are retracting this Article because of our failure to reproduce the molecular weight dispersities (PDI) shown in Fig. 4 using the chain-transfer agent described in the paper (CTA1). While the degenerate chain-transfer mechanism described in Fig. 3 is correct, the best molecular weight dispersities that could be reproduced with the chain-transfer agent shown in the Article are much larger (PDI > 2.0) than reported.We have since studied the kinetics of CTA1 in comparison with several other chain-transfer agents we are currently investigating and we now understand that the reactivity of CTA1 towards propagating ruthenium alkylidene complexes is very low. Very long monomer addition times would therefore have been necessary to gain control over the molecular weight distribution. Such long addition times would exceed the lifetime of the Grubbs catalyst in solution. Faster addition of the monomer has since repeatedly been shown to broaden the molecular weight dispersity.Additionally, the best chain-transfer agents we are currently investigating are orders of magnitude more reactive than CTA1 but give broader molecular weight dispersities than reported in Fig. 4. Molecular weight and dispersity control as shown in Fig. 4 is therefore an inappropriate claim for CTA1.The authors deeply regret these errors and apologize to the community.

  3. Crosslinking hydroxylated reduced graphene oxide with RAFT-CTA: A nano-initiator for preparation of well-defined amino acid-based polymer nanohybrids.

    PubMed

    Namvari, Mina; Biswas, Chandra S; Wang, Qiao; Liang, Wenlang; Stadler, Florian J

    2017-10-15

    Here, we demonstrate a novel reversible addition-fragmentation chain transfer agent (RAFT-CTA)-modified reduced graphene oxide nanosheets (CTA-rGONSs) by crosslinking rGONSs with a RAFT-CTA via esterification reaction. These nano CTA-rGONSs were used to polymerize a hydrophobic amino acid-based methacrylamide (N-acryloyl-l-phenylalanine methyl ester) monomer with different monomer/initiator ratios. Thermogravimetric analysis showed that the polymer-graphene composites were thermally more stable than GO itself. M n of the polymers increased with increasing monomer/initiator ratio, while the polydispersity index decreased, indicating controlled polymerization. The composites were stable in DMF even after two months. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Radiation-induced controlled polymerization of acrylic acid by RAFT and RAFT-MADIX methods in protic solvents

    NASA Astrophysics Data System (ADS)

    Sütekin, S. Duygu; Güven, Olgun

    2018-01-01

    The kinetic investigation of one-pot synthesis of poly(acrylic acid) (PAA) prepared via gamma radiation induced controlled polymerization was reported. PAA homopolymers were prepared by Reversible Addition-Fragmentation Chain Transfer (RAFT) polymerization in the presence of trithiocarbonate-based chain transfer agent (CTA) 2-(Dodecylthiocarbonothioylthio)-2-methylpropionic acid (DDMAT) and also by Reversible Addition-Fragmentation/Macromolecular Design by Inter-change of Xanthates (RAFT/MADIX) polymerization in the presence of a xanthate based CTA O-ethyl-S-(1-methoxycarbonyl) ethyl dithiocarbonate (RA1). The polymerizations were performed at room temperature by the virtue of ionizing radiation. Protic solvents were used for the RAFT polymerization of AA considering environmental profits. The linear first-order kinetic plot, close control of molecular weight by the monomer/CTA molar ratio supported that the polymerization proceeds in a living fashion. The linear increase in molecular weight with conversion monitored by Size Exclusion Chromatography (SEC) is another proof of controlling of polymerization. [Monomer]/[RAFT] ratio and conversion was controlled to obtain PAA in the molecular weight range of 6900-35,800 with narrow molecular weight distributions. Reaction kinetics and effect of the amount of RAFT agent were investigated in detail. Between two different types of CTA, trithiocarbonate based DDMAT was found to be more efficient in terms of low dispersity (Đ) and linear first-order kinetic behavior for the radiation induced controlled synthesis of PAA homopolymers.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jongmin; Saba, Stacey A.; Hillmyer, Marc A.

    We report on the phase separation behaviors of polymerization mixtures containing a polylactide macro-chain transfer agent (PLA-CTA), styrene, divinylbenzene, hydroxyl-terminated PLA (PLA-OH), and a molecular chain transfer agent which enable the ability to tune the pore size of a cross-linked polymer monolith in a facile manner. Cross-linked monoliths were produced from the mixtures via reversible addition-fragmentation chain transfer (RAFT) polymerization and converted into cross-linked porous polymers by selective removal of PLA while retaining the parent morphology. We demonstrate that pore sizes are tunable over a wide range of length scales from the meso- to macroporous regimes by adjusting the ratiomore » of PLA-CTA to PLA-OH in the reaction mixture which causes the phase separation mechanism to change from polymerization-induced microphase separation to polymerization-induced phase separation. The possibility of increasing porosity and inducing simultaneous micro- and macrophase separation was also realized by adjustments in the molar mass of PLA which enabled the synthesis of hierarchically meso- and macroporous polymers.« less

  6. Reversible Addition Fragmentation Chain Transfer (RAFT) Polymerization of 4-Vinylbenzaldehyde

    PubMed Central

    Sun, Guorong; Cheng, Chong; Wooley, Karen L.

    2008-01-01

    The direct reversible addition fragmentation chain transfer (RAFT) polymerization of 4-vinylbenzaldehyde (VBA) was established as a new synthetic method for the preparation of well-defined poly(vinylbenzaldehyde) (PVBA), a polymer having reactive aldehyde side chain substiuents. RAFT polymerization of VBA was investigated using S-1-dodecyl-S’-(α,α’-dimethyl-α”-acetic acid)trithiocarbonate (DDMAT) as chain transfer agent (CTA) and 2,2′-azobis(isobutyronitrile) (AIBN) as initiator in 1,4-dioxane or 2-butanone at 70-75 °C for 7.5-22.5 h. With 45-76% of monomer conversion, the resulting PVBA had well controlled number-average molecular weight (Mn) and low polydispersity (PDI < 1.17). The living characteristic of the RAFT polymerization process was confirmed by the linearity between the Mn values of PVBA and monomer conversions. Well-defined PVBA was further used as a macromolecular chain transfer agent (macro-CTA) in RAFT polymerization of styrene (St), and a block copolymer PVBA-b-PSt with relatively low polydispersity (PDI = 1.20) was successfully synthesized. PMID:19066633

  7. Synthesis, Characterization and Application of Thermoresponsive Polyhydroxyalkanoate-graft-Poly(N-isopropylacrylamide).

    PubMed

    Ma, Yi-Ming; Wei, Dai-Xu; Yao, Hui; Wu, Lin-Ping; Chen, Guo-Qiang

    2016-08-08

    A thermoresponsive graft copolymer polyhydroxyalkanoate-g-poly(N-isopropylacrylamide) or short as PHA-g-PNIPAm, was successfully synthesized via a three-step reaction. First, PNIPAm oligomer with a trithiocarbonate-based chain transfer agent (CTA), short as PNIPAm-CTA, with designed polymerization degree was synthesized via reversible addition-fragmentation chain transfer (RAFT) polymerization. Subsequently, the PNIPAm-CTA was treated with n-butylamine for aminolysis in order to obtain a pendant thiol group at the end of the chain (PNIPAm-SH). Finally, the PNIPAm-SH was grafted onto unsaturated P(3HDD-co-3H10U), a random copolymer of 3-hydroxydodecanoate (3HDD) and 3-hydroxy-10-undecylenate (3H10U), via a thiol-ene click reaction. Enhanced hydrophilicity and thermoresponsive property of the resulted PHA-g-PNIPAm were confirmed by water contact angle studies. The biocompatibility of PHA-g-PNIPAm was comparable to poly-3-hydroxybutyrate (PHB). The graft copolymer PHA-g-PNIPAm based on biopolyester PHA could be a promising material for biomedical applications.

  8. Carprofen-imprinted monolith prepared by reversible addition-fragmentation chain transfer polymerization in room temperature ionic liquids.

    PubMed

    Ban, Lu; Han, Xu; Wang, Xian-Hua; Huang, Yan-Ping; Liu, Zhao-Sheng

    2013-10-01

    To obtain fast separation, ionic liquids were used as porogens first in combination with reversible addition-fragmentation chain transfer (RAFT) polymerization to prepare a new type of molecularly imprinted polymer (MIP) monolith. The imprinted monolithic column was synthesized using a mixture of carprofen (template), 4-vinylpyridine, ethylene glycol dimethacrylate, [BMIM]BF4, and chain transfer agent (CTA). Some polymerization factors, such as template-monomer molar ratio, the degree of crosslinking, the composition of the porogen, and the content of CTA, on the column efficiency and imprinting effect of the resulting MIP monolith were systematically investigated. Affinity screening of structurally similar compounds with the template can be achieved in 200 s on the MIP monolith due to high column efficiency (up to 12,070 plates/m) and good column permeability. Recognition mechanism of the imprinted monolith was also investigated.

  9. Improved Livingness and Control over Branching in RAFT Polymerization of Acrylates: Could Microflow Synthesis Make the Difference?

    PubMed

    Derboven, Pieter; Van Steenberge, Paul H M; Vandenbergh, Joke; Reyniers, Marie-Francoise; Junkers, Thomas; D'hooge, Dagmar R; Marin, Guy B

    2015-12-01

    The superior capabilities of structured microreactors over batch reactors are demonstrated for reversible addition-fragmentation chain transfer (RAFT) solution polymerization of n-butyl acrylate with the aid of simulations, explicitly accounting for the chain length distribution of all macrospecies types. Since perfect isothermicity can be established in a microreactor, less side products due to backbiting and β-scission are formed compared to the batch operation in which ineffective heat removal leads to an undesirable temperature spike. For a given RAFT chain transfer agent (CTA), additional microstructural control results under microflow conditions by optimizing the reaction temperature, lowering the dilution degree, or decreasing the initial molar ratio of monomer to RAFT CTA. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The effect of glutathione as chain transfer agent in PNIPAAm-based thermo-responsive hydrogels for controlled release of proteins.

    PubMed

    Drapala, Pawel W; Jiang, Bin; Chiu, Yu-Chieh; Mieler, William F; Brey, Eric M; Kang-Mieler, Jennifer J; Pérez-Luna, Victor H

    2014-03-01

    To control degradation and protein release using thermo-responsive hydrogels for localized delivery of anti-angiogenic proteins. Thermo-responsive hydrogels derived from N-isopropylacrylamide (NIPAAm) and crosslinked with poly(ethylene glycol)-co-(L-lactic acid) diacrylate (Acry-PLLA-b-PEG-b-PLLA-Acry) were synthesized via free radical polymerization in the presence of glutathione, a chain transfer agent (CTA) added to modulate their degradation and release properties. Immunoglobulin G (IgG) and the recombinant proteins Avastin® and Lucentis® were encapsulated in these hydrogels and their release was studied. The encapsulation efficiency of IgG was high (75-87%) and decreased with CTA concentration. The transition temperature of these hydrogels was below physiological temperature, which is important for minimally invasive therapies involving these materials. The toxicity from unreacted monomers and free radical initiators was eliminated with a minimum of three buffer extractions. Addition of CTA accelerated degradation and resulted in complete protein release. Glutathione caused the degradation products to become solubilized even at 37°C. Hydrogels prepared without glutathione did not disintegrate nor released protein completely after 3 weeks at 37°C. PEGylation of IgG postponed the burst release effect. Avastin® and Lucentis® released from degraded hydrogels retained their biological activity. These systems offer a promising platform for the localized delivery of proteins.

  11. Well-defined single polymer nanoparticles for the antibody-targeted delivery of chemotherapeutic agents.

    PubMed

    Lane, D D; Chiu, D Y; Su, F Y; Srinivasan, S; Kern, H B; Press, O W; Stayton, P S; Convertine, A J

    2015-02-28

    Aqueous reversible addition-fragmentation chain transfer (RAFT) polymerization was employed to prepare a series of linear copolymers of N,N-dimethylacrylamide (DMA) and 2-hydroxyethylacrylamide (HEAm) with narrow Đ values over a molecular weight range spanning three orders of magnitude (10 3 to 10 6 Da). Trithiocarbonate-based RAFT chain transfer agents (CTAs) were grafted onto these scaffolds using carbodiimide chemistry catalyzed with DMAP. The resultant graft chain transfer agent (gCTA) was subsequently employed to synthesize polymeric brushes with a number of important vinyl monomer classes including acrylamido, methacrylamido, and methacrylate. Brush polymerization kinetics were evaluated for the aqueous RAFT polymerization of DMA from a 10 arm gCTA. Polymeric brushes containing hydroxyl functionality were further functionalized in order to prepare 2nd generation gCTAs which were subsequently employed to prepare polymers with a brushed-brush architecture with molecular weights in excess of 10 6 Da. These resultant single particle nanoparticles (SNPs) were employed as drug delivery vehicles for the anthracycline-based drug doxorubicin via copolymerization of DMA with a protected carbazate monomer (bocSMA). Cell-specific targeting functionality was also introduced via copolymerization with a biotin-functional monomer (bioHEMA). Drug release of the hydrazone linked doxorubicin was evaluated as function of pH and serum and chemotherapeutic activity was evaluated in SKOV3 ovarian cancer cells.

  12. Mapping the vascular anatomy of free transplanted soft tissue flaps with computed tomographic angiography.

    PubMed

    Rozen, Warren M; Chubb, Daniel; Ashton, Mark W; Webster, Howard R

    2012-05-01

    The use of advanced imaging technologies such as computed tomographic angiography (CTA) has opened the door to the analysis of microvascular anatomy not previously demonstrable with prior imaging techniques. While CTA has been used to evaluate the vascular anatomy of donor body regions in the planning of harvest of tissue for free flap transfer, the use of CTA to evaluate tissues after tissue transplantation has not been demonstrated. The current study aimed to explore whether vascular anatomy was able to highlight CTA within transferred flaps. The arterial and venous anatomy of a transferred deep inferior epigastric artery (DIEA) perforator (DIEP) flap was explored postoperatively with the use of CTA. Intra-flap vasculature was mapped and recorded qualitatively. Postoperative CTA is able to highlight the vascular pedicle of a transferred free flap, highlight the course of individual perforators supplying the flap, and map the zones of lesser perfusion by the source pedicle. The current study has demonstrated that CTA may be of value in identifying vascular anatomy within transferred tissue, as a guide to evaluate flap perfusion and planning further surgery involving the flap. © Springer-Verlag 2011

  13. Synthesis of surface-anchored DNA-polymer bioconjugates using reversible addition-fragmentation chain transfer polymerization.

    PubMed

    He, Peng; He, Lin

    2009-07-13

    We report here an approach to grafting DNA-polymer bioconjugates on a planar solid support using reversible addition-fragmentation chain transfer (RAFT) polymerization. In particular, a trithiocarbonate compound as the RAFT chain transfer agent (CTA) is attached to the distal point of a surface-immobilized oligonucleotide. Initiation of RAFT polymerization leads to controlled growth of polymers atop DNA molecules on the surface. Growth kinetics of poly(monomethoxy-capped oligo(ethylene glycol) methacrylate) atop DNA molecules is investigated by monitoring the change of polymer film thickness as a function of reaction time. The reaction conditions, including the polymerization temperature, the initiator concentration, the CTA surface density, and the selection of monomers, are varied to examine their impacts on the grafting efficiency of DNA-polymer conjugates. Comparing to polymer growth atop small molecules, the experimental results suggest that DNA molecules significantly accelerate polymer growth, which is speculated as a result of the presence of highly charged DNA backbones and purine/pyrimidine moieties surrounding the reaction sites.

  14. Highly Efficient One-Pot Synthesis of COS-Based Block Copolymers by Using Organic Lewis Pairs.

    PubMed

    Yang, Jia-Liang; Cao, Xiao-Han; Zhang, Cheng-Jian; Wu, Hai-Lin; Zhang, Xing-Hong

    2018-01-31

    A one-pot synthesis of block copolymer with regioregular poly(monothiocarbonate) block is described via metal-free catalysis. Lewis bases such as guanidine, quaternary onium salts, and Lewis acid triethyl borane (TEB) were equivalently combined and used as the catalysts. By using polyethylene glycol (PEG) as the macromolecular chain transfer agent (CTA), narrow polydispersity block copolymers were obtained from the copolymerization of carbonyl sulfide (COS) and propylene oxide (PO). The block copolymers had a poly(monothiocarbonate) block with perfect alternating degree and regioregularity. Unexpectedly, the addition of CTA to COS/PO copolymerization system could dramatically improve the turnover frequency (TOF) of PO (up to 240 h -1 ), higher than that of the copolymerization without CTA. In addition, the conversion of CTA could be up to 100% in most cases, as revealed by ¹H NMR spectra. Of consequence, the number-average molecular weights ( M n s) of the resultant block copolymers could be regulated by varying the feed ratio of CTA to PO. Oxygen-sulfur exchange reaction (O/S ER), which can generate randomly distributed thiocarbonate and carbonate units, was effectively suppressed in all of the cases in the presence of CTA, even at 80 °C. This work presents a versatile method for synthesizing sulfur-containing block copolymers through a metal-free route, providing an array of new block copolymers.

  15. Cost-effectiveness of a novel blood-pool contrast agent in the setting of chest pain evaluation in an emergency department.

    PubMed

    Espinosa, Gabriela; Annapragada, Ananth

    2013-10-01

    We evaluated three diagnostic strategies with the objective of comparing the current standard of care for individuals presenting acute chest pain and no history of coronary artery disease (CAD) with a novel diagnostic strategy using an emerging technology (blood-pool contrast agent [BPCA]) to identify the potential benefits and cost reductions. A decision analytic model of diagnostic strategies and outcomes using a BPCA and a conventional agent for CT angiography (CTA) in patients with acute chest pain was built. The model was used to evaluate three diagnostic strategies: CTA using a BPCA followed by invasive coronary angiography (ICA), CTA using a conventional agent followed by ICA, and ICA alone. The use of the two CTA-based triage tests before ICA in a population with a CAD prevalence of less than 47% was predicted to be more cost-effective than ICA alone. Using the base-case values and a cost premium for BPCA over the conventional CT agent (cost of BPCA ≈ 5× that of a conventional agent) showed that CTA with a BPCA before ICA resulted in the most cost-effective strategy; the other strategies were ruled out by simple dominance. The model strongly depends on the rates of complications from the diagnostic tests included in the model. In a population with an elevated risk of contrast-induced nephropathy (CIN), a significant premium cost per BPCA dose still resulted in the alternative whereby CTA using BPCA was more cost-effective than CTA using a conventional agent. A similar effect was observed for potential complications resulting from the BPCA injection. Conversely, in the presence of a similar complication rate from BPCA, the diagnostic strategy of CTA using a conventional agent would be the optimal alternative. BPCAs could have a significant impact in the diagnosis of acute chest pain, in particular for populations with high incidences of CIN. In addition, a BPCA strategy could garner further savings if currently excluded phenomena including renal disease and incidental findings were included in the decision model.

  16. Evaluation of Isoprene Chain Extension from PEO Macromolecular Chain Transfer Agents for the Preparation of Dual, Invertible Block Copolymer Nanoassemblies.

    PubMed

    Bartels, Jeremy W; Cauët, Solène I; Billings, Peter L; Lin, Lily Yun; Zhu, Jiahua; Fidge, Christopher; Pochan, Darrin J; Wooley, Karen L

    2010-09-14

    Two RAFT-capable PEO macro-CTAs, 2 and 5 kDa, were prepared and used for the polymerization of isoprene which yielded well-defined block copolymers of varied lengths and compositions. GPC analysis of the PEO macro-CTAs and block copolymers showed remaining unreacted PEO macro-CTA. Mathematical deconvolution of the GPC chromatograms allowed for the estimation of the blocking efficiency, about 50% for the 5 kDa PEO macro-CTA and 64% for the 2 kDa CTA. Self assembly of the block copolymers in both water and decane was investigated and the resulting regular and inverse assemblies, respectively, were analyzed with DLS, AFM, and TEM to ascertain their dimensions and properties. Assembly of PEO-b-PIp block copolymers in aqueous solution resulted in well-defined micelles of varying sizes while the assembly in hydrophobic, organic solvent resulted in the formation of different morphologies including large aggregates and well-defined cylindrical and spherical structures.

  17. Backbone degradable multiblock N-(2-hydroxypropyl)methacrylamide copolymer conjugates via reversible addition-fragmentation chain transfer polymerization and thiol-ene coupling reaction.

    PubMed

    Pan, Huaizhong; Yang, Jiyuan; Kopecková, Pavla; Kopecek, Jindrich

    2011-01-10

    Telechelic water-soluble HPMA copolymers and HPMA copolymer-doxorubicin (DOX) conjugates have been synthesized by RAFT polymerization mediated by a new bifunctional chain transfer agent (CTA) that contains an enzymatically degradable oligopeptide sequence. Postpolymerization aminolysis followed by chain extension with a bis-maleimide resulted in linear high molecular weight multiblock HPMA copolymer conjugates. These polymers are enzymatically degradable; in addition to releasing the drug (DOX), the degradation of the polymer backbone resulted in products with molecular weights similar to the starting material and below the renal threshold. The new multiblock HPMA copolymers hold potential as new carriers of anticancer drugs.

  18. Acceptance of Combined Coronary CT Angiography and Myocardial CT Perfusion versus Conventional Coronary Angiography in Patients with Coronary Stents—Intraindividual Comparison

    PubMed Central

    Martus, Peter; Laule, Michael; Dewey, Marc; Schönenberger, Eva

    2015-01-01

    Objectives To evaluate how well patients with coronary stents accept combined coronary computed tomography angiography (CTA) and myocardial CT perfusion (CTP) compared with conventional coronary angiography (CCA). Background While combined CTA and CTP may improve diagnostic accuracy compared with CTA alone, patient acceptance of CTA/CTP remains to be defined. Methods A total of 90 patients with coronary stents prospectively underwent CTA/CTP (both with contrast agent, CTP with adenosine) and CCA as part of the CARS-320 study. In this group, an intraindividual comparison of patient acceptance of CTA, CTP, and CCA was performed. Results CTP was experienced to be significantly more painful than CTA (p<0.001) and was associated with a higher frequency of dyspnea (p<0.001). Comparison of CTA/CTP with CCA revealed no significant differences in terms of pain (p = 0.141) and comfort (p = 0.377). Concern before CTA/CTP and CCA and overall satisfaction were likewise not significantly different (p = 0.097 and p = 0.123, respectively). Nevertheless, about two thirds (n = 60, 68%) preferred CTA/CTP to CCA (p<0.001). Moreover, patients felt less helpless during CTA/CTP than during CCA (p = 0.026). Lack of invasiveness and absence of pain were the most frequently mentioned advantages of CTA/CTP over CCA in our patient population. Conclusions CCA and combined CTA/CTP are equally well accepted by patients; however, more patients prefer CTA/CTP. CTP was associated with more intense pain than CTA and more frequently caused dyspnea than CTA alone. Trial Registration ClinicalTrials.gov NCT00967876 PMID:26327127

  19. Electroactivity of Aptamer at Soft Microinterface Arrays.

    PubMed

    Felisilda, Bren Mark B; Arrigan, Damien W M

    2018-06-26

    The electrochemical behavior of a synthetic oligonucleotide, thrombin-binding aptamer (TBA, 15-mer), was explored at a liquid-organogel microinterface array. TBA did not display any response when only background electrolytes were present in both phases. On the basis of literature reports that surfactants can influence nucleic acid detection, the response in the presence of cetyltrimethylammonium (CTA + ) was examined. With both TBA and CTA + in the aqueous phase, the transfer current for CTA + was diminished, signifying the interaction of CTA + with TBA. Experiments with CTA + spiked into the organic phase revealed a sharp current peak, consistent with the interfacial formation of a CTA + -TBA complex. However, use of CTA + as the organic phase electrolyte cation, as the salt with tetrakis(4-chlorophenyl)borate, greatly improved the response to TBA. In this case, a distinctive peak response (at ca. -0.25 V) was attributed to the transfer of CTA + across the soft interface to complex with aqueous phase TBA. Employing this process as a detection step enabled a detection limit of 0.11 μM TBA (by cyclic voltammetry). Furthermore, the presence of magnesium cations at physiological concentration resulted in the disappearance of the TBA response because of Mg 2+ -induced folding of TBA. Also, the current response of TBA was decreased by the addition of thrombin, indicating TBA interacted with this binding partner. Finally, the interfacial surfactant-aptamer interaction was explored in a synthetic urine matrix that afforded a detection limit of 0.29 μM TBA. These results suggest that aptamer-binding interactions can be monitored by electrochemistry at aqueous-organic interfaces and open up a new possibility for detection in aptamer-binding assays.

  20. Computed Tomography Angiography in Microsurgery: Indications, Clinical Utility, and Pitfalls

    PubMed Central

    Lee, Gordon K.; Fox, Paige M.; Riboh, Jonathan; Hsu, Charles; Saber, Sepideh; Rubin, Geoffrey D.; Chang, James

    2013-01-01

    Objective: Computed tomographic angiography (CTA) can be used to obtain 3-dimensional vascular images and soft-tissue definition. The goal of this study was to evaluate the reliability, usefulness, and pitfalls of CTA in preoperative planning of microvascular reconstructive surgery. Methods: A retrospective review of patients who obtained preoperative CTA in preparation for planned microvascular reconstruction was performed over a 5-year period (2001–2005). The influence of CTA on the original operative plan was assessed for each patient, and CTA results were correlated to the operative findings. Results: Computed tomographic angiography was performed on 94 patients in preparation for microvascular reconstruction. In 48 patients (51%), vascular abnormalities were noted on CTA. Intraoperative findings correlated with CTA results in 97% of cases. In 42 patients (45%), abnormal CTA findings influenced the original operative plan, such as the choice of vessels, side of harvest, or nature of the reconstruction (local flap instead of free tissue transfer). Technical difficulties in performing CTA were encountered in 5 patients (5%) in whom interference from external fixation devices was the main cause. Conclusions: This large study of CTA obtained for preoperative planning of reconstructive microsurgery at both donor and recipient sites study demonstrates that CTA is safe and highly accurate. Computed tomographic angiography can alter the surgeon's reconstructive plan when abnormalities are noted preoperatively and consequently improve results by decreasing vascular complication rates. The use of CTA should be considered for cases of microsurgical reconstruction where the vascular anatomy may be questionable. PMID:24023972

  1. Gas hold-up and oxygen mass transfer in three pneumatic bioreactors operating with sugarcane bagasse suspensions.

    PubMed

    Esperança, M N; Cunha, F M; Cerri, M O; Zangirolami, T C; Farinas, C S; Badino, A C

    2014-05-01

    Sugarcane bagasse is a low-cost and abundant by-product generated by the bioethanol industry, and is a potential substrate for cellulolytic enzyme production. The aim of this work was to evaluate the effects of air flow rate (QAIR), solids loading (%S), sugarcane bagasse type, and particle size on the gas hold-up (εG) and volumetric oxygen transfer coefficient (kLa) in three different pneumatic bioreactors, using response surface methodology. Concentric tube airlift (CTA), split-cylinder airlift (SCA), and bubble column (BC) bioreactor types were tested. QAIR and %S affected oxygen mass transfer positively and negatively, respectively, while sugarcane bagasse type and particle size (within the range studied) did not influence kLa. Using large particles of untreated sugarcane bagasse, the loop-type bioreactors (CTA and SCA) exhibited higher mass transfer, compared to the BC reactor. At higher %S, SCA presented a higher kLa value (0.0448 s−1) than CTA, and the best operational conditions in terms of oxygen mass transfer were achieved for %S < 10.0 g L−1 and QAIR > 27.0 L min−1. These results demonstrated that pneumatic bioreactors can provide elevated oxygen transfer in the presence of vegetal biomass, making them an excellent option for use in three-phase systems for cellulolytic enzyme production by filamentous fungi.

  2. Towards a flexible array control and operation framework for CTA

    NASA Astrophysics Data System (ADS)

    Birsin, E.; Colomé, J.; Hoffmann, D.; Koeppel, H.; Lamanna, G.; Le Flour, T.; Lopatin, A.; Lyard, E.; Melkumyan, D.; Oya, I.; Panazol, J.-L.; Schlenstedt, S.; Schmidt, T.; Schwanke, U.; Stegmann, C.; Walter, R.; Wegner, P.; CTA Consortium

    2012-12-01

    The Cherenkov Telescope Array (CTA) [1] will be the successor to current Imaging Atmospheric Cherenkov Telescopes (IACT) like H.E.S.S., MAGIC and VERITAS. CTA will improve in sensitivity by about an order of magnitude compared to the current generation of IACTs. The energy range will extend from well below 100 GeV to above 100 TeV. To accomplish these goals, CTA will consist of two arrays, one in each hemisphere, consisting of 50-80 telescopes and composed of three different telescope types with different mirror sizes. It will be the first open observatory for very high energy γ-ray astronomy. The Array Control working group of CTA is currently evaluating existing technologies which are best suited for a project like CTA. The considered solutions comprise the ALMA Common Software (ACS), the OPC Unified Architecture (OPC UA) and the Data Distribution Service (DDS) for bulk data transfer. The first applications, like an automatic observation scheduler and the control software for some prototype instrumentation have been developed.

  3. Respiration triggers heme transfer from cytochrome c peroxidase to catalase in yeast mitochondria

    PubMed Central

    Kathiresan, Meena; Martins, Dorival; English, Ann M.

    2014-01-01

    In exponentially growing yeast, the heme enzyme, cytochrome c peroxidase (Ccp1) is targeted to the mitochondrial intermembrane space. When the fermentable source (glucose) is depleted, cells switch to respiration and mitochondrial H2O2 levels rise. It has long been assumed that CCP activity detoxifies mitochondrial H2O2 because of the efficiency of this activity in vitro. However, we find that a large pool of Ccp1 exits the mitochondria of respiring cells. We detect no extramitochondrial CCP activity because Ccp1 crosses the outer mitochondrial membrane as the heme-free protein. In parallel with apoCcp1 export, cells exhibit increased activity of catalase A (Cta1), the mitochondrial and peroxisomal catalase isoform in yeast. This identifies Cta1 as a likely recipient of Ccp1 heme, which is supported by low Cta1 activity in ccp1Δ cells and the accumulation of holoCcp1 in cta1Δ mitochondria. We hypothesized that Ccp1’s heme is labilized by hyperoxidation of the protein during the burst in H2O2 production as cells begin to respire. To test this hypothesis, recombinant Ccp1 was hyperoxidized with excess H2O2 in vitro, which accelerated heme transfer to apomyoglobin added as a surrogate heme acceptor. Furthermore, the proximal heme Fe ligand, His175, was found to be ∼85% oxidized to oxo-histidine in extramitochondrial Ccp1 isolated from 7-d cells, indicating that heme labilization results from oxidation of this ligand. We conclude that Ccp1 responds to respiration-derived H2O2 via a previously unidentified mechanism involving H2O2-activated heme transfer to apoCta1. Subsequently, the catalase activity of Cta1, not CCP activity, contributes to mitochondrial H2O2 detoxification. PMID:25422453

  4. Respiration triggers heme transfer from cytochrome c peroxidase to catalase in yeast mitochondria.

    PubMed

    Kathiresan, Meena; Martins, Dorival; English, Ann M

    2014-12-09

    In exponentially growing yeast, the heme enzyme, cytochrome c peroxidase (Ccp1) is targeted to the mitochondrial intermembrane space. When the fermentable source (glucose) is depleted, cells switch to respiration and mitochondrial H2O2 levels rise. It has long been assumed that CCP activity detoxifies mitochondrial H2O2 because of the efficiency of this activity in vitro. However, we find that a large pool of Ccp1 exits the mitochondria of respiring cells. We detect no extramitochondrial CCP activity because Ccp1 crosses the outer mitochondrial membrane as the heme-free protein. In parallel with apoCcp1 export, cells exhibit increased activity of catalase A (Cta1), the mitochondrial and peroxisomal catalase isoform in yeast. This identifies Cta1 as a likely recipient of Ccp1 heme, which is supported by low Cta1 activity in ccp1Δ cells and the accumulation of holoCcp1 in cta1Δ mitochondria. We hypothesized that Ccp1's heme is labilized by hyperoxidation of the protein during the burst in H2O2 production as cells begin to respire. To test this hypothesis, recombinant Ccp1 was hyperoxidized with excess H2O2 in vitro, which accelerated heme transfer to apomyoglobin added as a surrogate heme acceptor. Furthermore, the proximal heme Fe ligand, His175, was found to be ∼ 85% oxidized to oxo-histidine in extramitochondrial Ccp1 isolated from 7-d cells, indicating that heme labilization results from oxidation of this ligand. We conclude that Ccp1 responds to respiration-derived H2O2 via a previously unidentified mechanism involving H2O2-activated heme transfer to apoCta1. Subsequently, the catalase activity of Cta1, not CCP activity, contributes to mitochondrial H2O2 detoxification.

  5. Three-dimensional venous visualization with phase-lag computed tomography angiography for reconstructive microsurgery.

    PubMed

    Sakakibara, Shunsuke; Onishi, Hiroyuki; Hashikawa, Kazunobu; Akashi, Masaya; Sakakibara, Akiko; Nomura, Tadashi; Terashi, Hiroto

    2015-05-01

    Most free flap reconstruction complications involve vascular compromise. Evaluation of vascular anatomy provides considerable information that can potentially minimize these complications. Previous reports have shown that contrast-enhanced computed tomography is effective for understanding three-dimensional arterial anatomy. However, most vascular complications result from venous thromboses, making imaging of venous anatomy highly desirable. The phase-lag computed tomography angiography (pl-CTA) technique involves 64-channel (virtually, 128-channel) multidetector CT and is used to acquire arterial images using conventional CTA. Venous images are three-dimensionally reconstructed using a subtraction technique involving combined venous phase and arterial phase images, using a computer workstation. This technique was used to examine 48 patients (12 lower leg reconstructions, 34 head and neck reconstructions, and 2 upper extremity reconstructions) without complications. The pl-CTA technique can be used for three-dimensional visualization of peripheral veins measuring approximately 1 mm in diameter. The pl-CTA information was especially helpful for secondary free flap reconstructions in the head and neck region after malignant tumor recurrence. In such cases, radical dissection of the neck was performed as part of the first operation, and many vessels, including veins, were resected and used in the first free-tissue transfer. The pl-CTA images also allowed visualization of varicose changes in the lower leg region and helped us avoid selecting those vessels for anastomosis. Thus, the pl-CTA-derived venous anatomy information was useful for exact evaluations during the planning of free-tissue transfers. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. FOST 2 Upgrade with Hollow-Fiber CTA FO Module and Generation of Osmotic Agent for Microorganism Growth Studies

    NASA Technical Reports Server (NTRS)

    Parodi, Jurek; Mangado, Jaione Romero; Stefanson, Ofir; Flynn, Michael; Shaw, Hali; Beeler, David

    2016-01-01

    FOST 2 is an integrated membrane system that incorporates a forward osmosis subsystem and a reverse osmosis subsystem working in series. It has been designed as a post treatment system to process the effluent from the Membrane Aerated Biological Reactor developed at NASA Johnson Space Center and Texas Tech University. Its function is to remove dissolved solids residual such as ammonia and suspended solids, as well as to provide a physical barrier to microbial and viral contamination. A tubular CTA membrane module from HTI and a flat-sheet lipid-base membrane module from Porifera were integrated and tested on FOST 2 in the past, using both a bioreactor's effluent and greywater as the feed solution. This paper documents the performance of FOST 2 after its upgrade with a hollow-fiber CTA membrane module from Toyobo, treating real black-water to generate the osmotic agent solution necessary to conduct growth studies of genetically engineered microorganism for the Synthetic Biological Membrane project.

  7. Reversible addition-fragmentation chain transfer polymerization of N-isopropylacrylamide: a comparison between a conventional and a fast initiator.

    PubMed

    Bouchékif, Hassen; Narain, Ravin

    2007-09-27

    The reversible addition-fragmentation chain transfer (RAFT) polymerization of N-isopropylacrylamide (NIPAM) was studied to determine the reasons for deviation of experimental molecular weights to lower molecular weight at high monomer conversion when S-1-dodecyl-S-(alpha,alpha'-dimethyl-alpha' '-acetic acid)trithiocarbonate (CTAm) and S,S-bis(alpha,alpha'-dimethyl-alpha' '-acetic acid)trithiocarbonate (CTAd) were used as RAFT agents at 65 degrees C. For this purpose, experiments were performed in N,N'-dimethylformamide (DMF) at the NIPAM/CTA ratio of 200 with initiators capable of yielding fast and slow initiation, respectively by photochemical and thermal process, either at ambient temperature or at 65 degrees C. When the polymerization of NIPAM was conducted under these conditions with Irgacure-2959 (IRGC) as photoinitiator, a continuing supply of primary radicals by incremental initiator addition was required to achieve reasonably high conversion. This effect was also apparent by the loss of linearity of the first-order kinetic plot with a conventional initiator (4,4-azobis(4-cyanovaleric acid) (ACVA) as azo-initiator, 10h (t1/2) decomposition at 65 degrees C) indicating that steady-state concentration of the macroradical decreases significantly with the initiator consumption. Nevertheless, polymers with predictable number-average molecular weight Mn (i.e., based on [monomer]/([CTA] + [initiator]) ratio) and narrow polydispersities were obtained (PDIs < 1.2) with CTAm indicating that the process of chain growth was controlled. When CTAd was used, instead of CTAm, the polymers obtained were characterized by a larger polydispersity (1.2 < PDIs < 1.3). The so-called "living steady-state concentration" in chain equilibration together with the linear dependence of Mn vs conversion was observed only when the 200/1 NIPAM/CTA mixture in DMF was subjected to a permanent photoirradiation at 65 degrees C. With ACVA, the deviation of the experimentally measured molecular weights at high conversion was accounted for by the simultaneous self-initiated polymerization of NIPAM with the controlled process in the presence of CTA at 65 degrees C. Similar drift from the linear dependence Mn vs conversion was also observed at 65 degrees C when a significant number of low molecular weight polymer chains were generated intentionally by photodecomposition of IRGC.

  8. A One-Step Route to CO2 -Based Block Copolymers by Simultaneous ROCOP of CO2 /Epoxides and RAFT Polymerization of Vinyl Monomers.

    PubMed

    Wang, Yong; Zhao, Yajun; Ye, Yunsheng; Peng, Haiyan; Zhou, Xingping; Xie, Xiaolin; Wang, Xianhong; Wang, Fosong

    2018-03-26

    The one-step synthesis of well-defined CO 2 -based diblock copolymers was achieved by simultaneous ring-opening copolymerization (ROCOP) of CO 2 /epoxides and RAFT polymerization of vinyl monomers using a trithiocarbonate compound bearing a carboxylic group (TTC-COOH) as the bifunctional chain transfer agent (CTA). The double chain-transfer effect allows for independent and precise control over the molecular weight of the two blocks and ensures narrow polydispersities of the resultant block copolymers (1.09-1.14). Notably, an unusual axial group exchange reaction between the aluminum porphyrin catalyst and TTC-COOH impedes the formation of homopolycarbonates. By taking advantage of the RAFT technique, it is able to meet the stringent demand for functionality control to well expand the application scopes of CO 2 -based polycarbonates. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. RAFT-synthesized Graft Copolymers that Enhance pH-dependent Membrane Destabilization and Protein Circulation Times

    PubMed Central

    Crownover, Emily; Duvall, Craig L.; Convertine, Anthony; Hoffman, Allan S.; Stayton, Patrick S.

    2012-01-01

    Here we describe a new graft copolymer architecture of poly(propylacrylic acid) (polyPAA) that displays potent pH-dependent, membrane-destabilizing activity and in addition is shown to enhance protein blood circulation kinetics. PolyPAA containing a single telechelic alkyne functionality was prepared via reversible addition-fragmentation chain transfer (RAFT) polymerization with an alkyne-functional chain transfer agent (CTA) and coupled to RAFT polymerized poly(azidopropyl methacrylate) (polyAPMA) through azide-alkyne [3+2] Huisgen cycloaddition. The graft copolymers become membrane destabilizing at endosomal pH values and are active at significantly lower concentrations than the linear polyPAA. A biotin terminated polyPAA graft copolymer was prepared by grafting PAA onto polyAPMA polymerized with a biotin functional RAFT CTA. The blood circulation time and biodistribution of tritium labeled avidin conjugated to the polyPAA graft copolymer was characterized along with a clinically utilized 40 kDa branched polyethylene glycol (PEG) also possessing biotin functionalization. The linear and graft polyPAA increase the area under the curve (AUC) over avidin alone by 9 and 12 times, respectively. Furthermore, polyPAA graft copolymer conjugates accumulated in tumor tissue significantly more than the linear polyPAA and the branched PEG conjugates. The collective data presented in this report indicate that the polyPAA graft copolymers exhibit robust pH-dependent, membrane-destabilizing activity, low cytotoxicity and significantly enhance blood circulation time and tumor accumulation. PMID:21699931

  10. Evaluation of right ventricular function by coronary computed tomography angiography using a novel automated 3D right ventricle volume segmentation approach: a validation study.

    PubMed

    Burghard, Philipp; Plank, Fabian; Beyer, Christoph; Müller, Silvana; Dörler, Jakob; Zaruba, Marc-Michael; Pölzl, Leo; Pölzl, Gerhard; Klauser, Andrea; Rauch, Stefan; Barbieri, Fabian; Langer, Christian-Ekkehardt; Schgoer, Wilfried; Williamson, Eric E; Feuchtner, Gudrun

    2018-06-04

    To evaluate right ventricle (RV) function by coronary computed tomography angiography (CTA) using a novel automated three-dimensional (3D) RV volume segmentation tool in comparison with clinical reference modalities. Twenty-six patients with severe end-stage heart failure [left ventricle (LV) ejection fraction (EF) <35%] referred to CTA were enrolled. A specific individually tailored biphasic contrast agent injection protocol was designed (80%/20% high/low flow) was designed. Measurement of RV function [EF, end-diastolic volume (EDV), end-systolic volume (ESV)] by CTA was compared with tricuspid annular plane systolic excursion (TAPSE) by transthoracic echocardiography (TTE) and right heart invasive catheterisation (IC). Automated 3D RV volume segmentation was successful in 26 (100%) patients. Read-out time was 3 min 33 s (range, 1 min 50s-4 min 33s). RV EF by CTA was stronger correlated with right atrial pressure (RAP) by IC (r = -0.595; p = 0.006) but weaker with TAPSE (r = 0.366, p = 0.94). When comparing TAPSE with RAP by IC (r = -0.317, p = 0.231), a weak-to-moderate non-significant inverse correlation was found. Interobserver correlation was high with r = 0.96 (p < 0.001), r = 0.86 (p < 0.001) and r = 0.72 (p = 0.001) for RV EDV, ESV and EF, respectively. CT attenuation of the right atrium (RA) and right ventricle (RV) was 196.9 ± 75.3 and 217.5 ± 76.1 HU, respectively. Measurement of RV function by CTA using a novel 3D volumetric segmentation tool is fast and reliable by applying a dedicated biphasic injection protocol. The RV EF from CTA is a closer surrogate of RAP than TAPSE by TTE. • Evaluation of RV function by cardiac CTA by using a novel 3D volume segmentation tool is fast and reliable. • A biphasic contrast agent injection protocol ensures homogenous RV contrast attenuation. • Cardiac CT is a valuable alternative modality to CMR for the evaluation of RV function.

  11. Preliminary effects of real-world factors on the recovery and exploitation of forensic impurity profiles of a nerve-agent simulant from office media.

    PubMed

    Fraga, Carlos G; Sego, Landon H; Hoggard, Jamin C; Acosta, Gabriel A Pérez; Viglino, Emilie A; Wahl, Jon H; Synovec, Robert E

    2012-12-28

    Dimethyl methylphosphonate (DMMP) was used as a chemical threat agent (CTA) simulant for a first look at the effects of real-world factors on the recovery and exploitation of a CTA's impurity profile for source matching. Four stocks of DMMP having different impurity profiles were disseminated as aerosols onto cotton, painted wall board, and nylon coupons according to a thorough experimental design. The DMMP-exposed coupons were then solvent extracted and analyzed for DMMP impurities by comprehensive 2D gas chromatography/mass spectrometry (GC×GC/MS). The similarities between the coupon DMMP impurity profiles and the known (reference) DMMP profiles were measured by dot products of the coupon profiles and known profiles and by score values obtained from principal component analysis. One stock, with a high impurity-profile selectivity value of 0.9 out of 1, had 100% of its respective coupons correctly classified and no false positives from other coupons. Coupons from the other three stocks with low selectivity values (0.0073, 0.012, and 0.018) could not be sufficiently distinguished from one another for reliable matching to their respective stocks. The results from this work support that: (1) extraction solvents, if not appropriately selected, can have some of the same impurities present in a CTA reducing a CTA's useable impurity profile, (2) low selectivity among a CTA's known impurity profiles will likely make definitive source matching impossible in some real-world conditions, (3) no detrimental chemical-matrix interference was encountered during the analysis of actual office media, (4) a short elapsed time between release and sample storage is advantageous for the recovery of the impurity profile because it minimizes volatilization of forensic impurities, and (5) forensic impurity profiles weighted toward higher volatility impurities are more likely to be altered by volatilization following CTA exposure. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Quantitative in vivo CT arthrography of the human osteoarthritic knee to estimate cartilage sulphated glycosaminoglycan content: correlation with ex-vivo reference standards.

    PubMed

    van Tiel, J; Siebelt, M; Reijman, M; Bos, P K; Waarsing, J H; Zuurmond, A-M; Nasserinejad, K; van Osch, G J V M; Verhaar, J A N; Krestin, G P; Weinans, H; Oei, E H G

    2016-06-01

    Recently, computed tomography arthrography (CTa) was introduced as quantitative imaging biomarker to estimate cartilage sulphated glycosaminoglycan (sGAG) content in human cadaveric knees. Our aim was to assess the correlation between in vivo CTa in human osteoarthritis (OA) knees and ex vivo reference standards for sGAG and collagen content. In this prospective observational study 11 knee OA patients underwent CTa before total knee replacement (TKR). Cartilage X-ray attenuation was determined in six cartilage regions. Femoral and tibial cartilage specimens harvested during TKR were re-scanned using equilibrium partitioning of an ionic contrast agent with micro-CT (EPIC-μCT), which served as reference standard for sGAG. Next, cartilage sGAG and collagen content were determined using dimethylmethylene blue (DMMB) and hydroxyproline assays. The correlation between CTa X-ray attenuation, EPIC-μCT X-ray attenuation, sGAG content and collagen content was assessed. CTa X-ray attenuation correlated well with EPIC-μCT (r = 0.76, 95% credibility interval (95%CI) 0.64 to 0.85). CTa correlated moderately with the DMMB assay (sGAG content) (r = -0.66, 95%CI -0.87 to -0.49) and to lesser extent with the hydroxyproline assay (collagen content) (r = -0.56, 95%CI -0.70 to -0.36). Outcomes of in vivo CTa in human OA knees correlate well with sGAG content. Outcomes of CTa also slightly correlate with cartilage collagen content. Since outcomes of CTa are mainly sGAG dependent and despite the fact that further validation using hyaline cartilage of other joints with different biochemical composition should be conducted, CTa may be suitable as quantitative imaging biomarker to estimate cartilage sGAG content in future clinical OA research. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  13. Vesselness propagation: a fast interactive vessel segmentation method

    NASA Astrophysics Data System (ADS)

    Cai, Wenli; Dachille, Frank; Harris, Gordon J.; Yoshida, Hiroyuki

    2006-03-01

    With the rapid development of multi-detector computed tomography (MDCT), resulting in increasing temporal and spatial resolution of data sets, clinical use of computed tomographic angiography (CTA) is rapidly increasing. Analysis of vascular structures is much needed in CTA images; however, the basis of the analysis, vessel segmentation, can still be a challenging problem. In this paper, we present a fast interactive method for CTA vessel segmentation, called vesselness propagation. This method is a two-step procedure, with a pre-processing step and an interactive step. During the pre-processing step, a vesselness volume is computed by application of a CTA transfer function followed by a multi-scale Hessian filtering. At the interactive stage, the propagation is controlled interactively in terms of the priority of the vesselness. This method was used successfully in many CTA applications such as the carotid artery, coronary artery, and peripheral arteries. It takes less than one minute for a user to segment the entire vascular structure. Thus, the proposed method provides an effective way of obtaining an overview of vascular structures.

  14. How You Can Partner with NIH | NCI Technology Transfer Center | TTC

    Cancer.gov

    NCI Technology Transfer Center (TTC) provides an array of agreements to support the National Cancer Institute's partnering. Deciding which type of agreement to use can be a challenge: CRADA, MTA, collaboration, agreement, CTA, Materials-CRADA

  15. Automatic aortic root segmentation in CTA whole-body dataset

    NASA Astrophysics Data System (ADS)

    Gao, Xinpei; Kitslaar, Pieter H.; Scholte, Arthur J. H. A.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Reiber, Johan H. C.

    2016-03-01

    Trans-catheter aortic valve replacement (TAVR) is an evolving technique for patients with serious aortic stenosis disease. Typically, in this application a CTA data set is obtained of the patient's arterial system from the subclavian artery to the femoral arteries, to evaluate the quality of the vascular access route and analyze the aortic root to determine if and which prosthesis should be used. In this paper, we concentrate on the automated segmentation of the aortic root. The purpose of this study was to automatically segment the aortic root in computed tomography angiography (CTA) datasets to support TAVR procedures. The method in this study includes 4 major steps. First, the patient's cardiac CTA image was resampled to reduce the computation time. Next, the cardiac CTA image was segmented using an atlas-based approach. The most similar atlas was selected from a total of 8 atlases based on its image similarity to the input CTA image. Third, the aortic root segmentation from the previous step was transferred to the patient's whole-body CTA image by affine registration and refined in the fourth step using a deformable subdivision surface model fitting procedure based on image intensity. The pipeline was applied to 20 patients. The ground truth was created by an analyst who semi-automatically corrected the contours of the automatic method, where necessary. The average Dice similarity index between the segmentations of the automatic method and the ground truth was found to be 0.965±0.024. In conclusion, the current results are very promising.

  16. Polyisobutylene chain end transformations: Block copolymer synthesis and click chemistry functionalizations

    NASA Astrophysics Data System (ADS)

    Magenau, Andrew Jackson David

    The primary objectives of this research were twofold: (1) development of synthetic procedures for combining quasiliving carbocationic polymerization (QLCCP) of isobutylene (IB) and reversible addition fragmentation chain transfer (RAFT) polymerization for block copolymer synthesis; (2) utilization of efficient, robust, and modular chemistries for facile functionalization of polyisobutylene (PIB). In the first study block copolymers consisting of PIB, and either PMMA or PS block segments, were synthesized by a site transformation approach combining living cationic and reversible addition-fragmentation chain transfer (RAFT) polymerizations. The initial PIB block was synthesized via quasiliving cationic polymerization using the TMPCl/TiCl4 initiation system and was subsequently converted into a hydroxylterminated PIB. Site transformation of the hydroxyl-terminated PIB into a macro chain transfer agent (PIB-CTA) was accomplished by N,N'-dicyclohexylcarbodiimide/dimethylaminopyridine-catalyzed esterification with 4-cyano-4-(dodecylsulfanylthiocarbonylsulfanyl)pentanoic acid. In the second study another site transformation approach was developed to synthesize a novel block copolymer, composed of PIB and PNIPAM segments. The PIB block was prepared via quasiliving cationic polymerization and end functionalized by in-situ quenching to yield telechelic halogen-terminated PIB. Azido functionality was obtained by displacement of the terminal halogen through nucleophilic substitution, which was confirmed by both 1H and 13C NMR. Coupling of an alkyne-functional chain transfer agent (CTA) to azido PIB was successfully accomplished through a copper catalyzed click reaction. Structure of the resulting PIB-based macro-CTA was verified with 1H NMR, FTIR, and GPC; whereas coupling reaction kinetics were monitored by real time variable temperature (VT) 1H NMR. In a third study, a click chemistry functionalization procedure was developed based upon the azide-alkyne 1,3-dipolar cycloaddition reaction. 1-(o-Azidoalkyl)pyrrolyl-terminated PIB was successfully synthesized both by substitution of the terminal halide of 1-(o-haloalkyl)pyrrolyl-terminated PIB with sodium azide and by in situ quenching of quasiliving PIB with a 1-(o-azidoalkyl)pyrrole. GPC indicated the absence of coupled PIB under optimized conditions, confirming exclusive mono-substitution on each pyrrole ring. In a fourth study, radical thiol-ene hydrothiolation "Click" chemistry was explored and adapted to easily and rapidly modify exo -olefin PIB with an array of thiol compounds bearing useful functionalities, including primary halogen, primary amine, primary hydroxyl, and carboxylic acid. The thiol-ene "click" procedure was shown to be applicable to both mono and difunctional exo-olefin polyisobutylene. Telechelic mono- and difunctional exo-olefin PIBs were synthesized via quasiliving cationic polymerization followed by quenching with the hindered amine, 1,2,2,6,6-pentamethylpiperidine. Lower reaction temperatures were found to increase exo-olefin conversion to near quantitative amounts. In the fifth study, thiol-terminated polyisobutylene (PIB-SH) was synthesized by reaction of thiourea with alpha,o-bromine-terminated PIB in a three step one-pot procedure. First the alkylisothiouronium salt was produced using a 1:1 (v:v) DMF:heptane cosolvent mixture at 90°C. Hydrolysis of the salt by aqueous base produced thiolate chain ends, which were then acidified to form the desired thiol functional group. An extension of this reaction was performed by a sequential thiol-ene/thiol-yne procedure to produce tetra-hydroxy functionalized PIB. 1H NMR was used to confirm formation of both alkyne and tetrahydroxyl functional species. Further utility of PIB-SH was demonstrated by base catalyzed thiol-isocyanate reactions. A model reaction was conducted with phenyl isocyanate in THF using triethylamine as the catalyst. Last, conversion of PIB-SH directly into a RAFT macro-CTA was accomplished, as shown by 1H NMR, by treatment of PIB-SH with triethylamine in carbon disulfide and subsequent alkylation with 2-bromopropionic acid. (Abstract shortened by UMI.)

  17. How to Create Conditioned Taste Aversion for Grazing Ground Covers in Woody Crops with Small Ruminants

    PubMed Central

    Manuelian, Carmen L.; Albanell, Elena; Rovai, Maristela; Caja, Gerardo

    2016-01-01

    Conditioned taste aversion (CTA) is a learning behavior process where animals are trained to reject certain feed after gastrointestinal discomfort has been produced. Lithium chloride (LiCl) is the preferred agent used in livestock to induce CTA because it specifically stimulates the vomit center. In addition, LiCl is commercially available, and easy to prepare and administer using a drenching gun. Nevertheless, some factors have to be considered to obtain an effective long-lasting CTA, which allows small ruminants to graze during the cropping season. A key aspect is to use animals with no previous contact with the target plant (the plant chosen to be avoided; new feed). Due to their native neophobic feeding behavior, small ruminants can easily associate the negative feedback effects with the new feed, resulting in a strong and persistent CTA. The recommended doses are 200 and 225 mg LiCl/kg body weight (BW) for goats and sheep, respectively. To induce CTA, 100 g of the target plant should be individually offered for at least 30 min, and LiCl administered thereafter if the intake is greater than 10 g. Each time the animal eats the target plant without negative consequences, the CTA becomes weaker. Consequently, to minimize the risk of target plant consumption, it is essential to have sufficient palatable ground cover available. The presence of an alternative feed (of quality and quantity) prevents the accidental consumption of the target plant. A close monitoring of the flock is recommended to remove and re-dose any animal consuming more than 4 bites or 10 g of the target plant. At the beginning of each grazing season, check the CTA status of each animal before moving them to the crop. PMID:27167860

  18. Poly(alkyl methacrylate) Brush-Grafted Silica Nanoparticles as Oil Lubricant Additives: Effects of Alkyl Pendant Groups on Oil Dispersibility, Stability, and Lubrication Property

    DOE PAGES

    Seymour, Bryan T.; Wright, Roger A. E.; Parrott, Alexander C.; ...

    2017-07-03

    This paper reports on the synthesis of a series of poly(alkyl methacrylate) brush-grafted, 23 nm silica nanoparticles (hairy NPs) and the study of the effect of alkyl pendant length on their use as oil lubricant additives for friction and wear reduction. The hairy NPs were prepared by surface-initiated reversible addition–fragmentation chain transfer polymerization from trithiocarbonate chain transfer agent (CTA)-functionalized silica NPs in the presence of a free CTA. We found that hairy NPs with sufficiently long alkyl pendant groups (containing >8 carbon atoms, such as 12, 13, 16, and 18 in this study) could be readily dispersed in poly(alphaolefin) (PAO),more » forming clear, homogeneous dispersions, and exhibited excellent stability at low and high temperatures as revealed by visual inspection and dynamic light scattering studies. Whereas poly(n-hexyl methacrylate) hairy NPs cannot be dispersed in PAO under ambient conditions or at 80 °C, interestingly, poly(2-ethylhexyl methacrylate) hairy NPs can be dispersed in PAO at 80 °C but not at room temperature, with a reversible clear-to-cloudy transition observed upon cooling. High-contact-stress ball-on-flat reciprocating sliding tribological tests at 100 °C showed significant reductions in both the coefficient of friction (up to 38%) and wear volume (up to 90% for iron flat) for transparent, homogeneous dispersions of hairy NPs in PAO at a concentration of 1.0 wt % compared with neat PAO. Finally, the formation of a load-bearing tribofilm at the rubbing interface was confirmed using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy.« less

  19. RAFT Aqueous Dispersion Polymerization Yields Poly(ethylene glycol)-Based Diblock Copolymer Nano-Objects with Predictable Single Phase Morphologies

    PubMed Central

    2013-01-01

    A poly(ethylene glycol) (PEG) macromolecular chain transfer agent (macro-CTA) is prepared in high yield (>95%) with 97% dithiobenzoate chain-end functionality in a three-step synthesis starting from a monohydroxy PEG113 precursor. This PEG113-dithiobenzoate is then used for the reversible addition–fragmentation chain transfer (RAFT) aqueous dispersion polymerization of 2-hydroxypropyl methacrylate (HPMA). Polymerizations conducted under optimized conditions at 50 °C led to high conversions as judged by 1H NMR spectroscopy and relatively low diblock copolymer polydispersities (Mw/Mn < 1.25) as judged by GPC. The latter technique also indicated good blocking efficiencies, since there was minimal PEG113 macro-CTA contamination. Systematic variation of the mean degree of polymerization of the core-forming PHPMA block allowed PEG113-PHPMAx diblock copolymer spheres, worms, or vesicles to be prepared at up to 17.5% w/w solids, as judged by dynamic light scattering and transmission electron microscopy studies. Small-angle X-ray scattering (SAXS) analysis revealed that more exotic oligolamellar vesicles were observed at 20% w/w solids when targeting highly asymmetric diblock compositions. Detailed analysis of SAXS curves indicated that the mean number of membranes per oligolamellar vesicle is approximately three. A PEG113-PHPMAx phase diagram was constructed to enable the reproducible targeting of pure phases, as opposed to mixed morphologies (e.g., spheres plus worms or worms plus vesicles). This new RAFT PISA formulation is expected to be important for the rational and efficient synthesis of a wide range of biocompatible, thermo-responsive PEGylated diblock copolymer nano-objects for various biomedical applications. PMID:24400622

  20. Poly(alkyl methacrylate) Brush-Grafted Silica Nanoparticles as Oil Lubricant Additives: Effects of Alkyl Pendant Groups on Oil Dispersibility, Stability, and Lubrication Property

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seymour, Bryan T.; Wright, Roger A. E.; Parrott, Alexander C.

    This paper reports on the synthesis of a series of poly(alkyl methacrylate) brush-grafted, 23 nm silica nanoparticles (hairy NPs) and the study of the effect of alkyl pendant length on their use as oil lubricant additives for friction and wear reduction. The hairy NPs were prepared by surface-initiated reversible addition–fragmentation chain transfer polymerization from trithiocarbonate chain transfer agent (CTA)-functionalized silica NPs in the presence of a free CTA. We found that hairy NPs with sufficiently long alkyl pendant groups (containing >8 carbon atoms, such as 12, 13, 16, and 18 in this study) could be readily dispersed in poly(alphaolefin) (PAO),more » forming clear, homogeneous dispersions, and exhibited excellent stability at low and high temperatures as revealed by visual inspection and dynamic light scattering studies. Whereas poly(n-hexyl methacrylate) hairy NPs cannot be dispersed in PAO under ambient conditions or at 80 °C, interestingly, poly(2-ethylhexyl methacrylate) hairy NPs can be dispersed in PAO at 80 °C but not at room temperature, with a reversible clear-to-cloudy transition observed upon cooling. High-contact-stress ball-on-flat reciprocating sliding tribological tests at 100 °C showed significant reductions in both the coefficient of friction (up to 38%) and wear volume (up to 90% for iron flat) for transparent, homogeneous dispersions of hairy NPs in PAO at a concentration of 1.0 wt % compared with neat PAO. Finally, the formation of a load-bearing tribofilm at the rubbing interface was confirmed using scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wieners, Gero, E-mail: gero.wieners@med.ovgu.d; Meyer, Frank; Halloul, Zuhir

    PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type IImore » was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.« less

  2. Immunomodulatory action of SGI-110, a hypomethylating agent, in acute myeloid leukemia cells

    PubMed Central

    Srivastava, Pragya; Paluch, Benjamin E.; Matsuzaki, Junko; James, Smitha R.; Collamat-Lai, Golda; Karbach, Julia; Nemeth, Michael J.; Taverna, Pietro; Karpf, Adam R.; Griffiths, Elizabeth A.

    2017-01-01

    The mechanism of clinical action for the FDA approved hypomethylating drugs azacitidine and decitabine remains unresolved and in this context the potential immunomodulatory effect of these agents on leukemic cells is an area of active investigation. Induced expression of methylated Cancer Testis Antigen (CTA) genes has been demonstrated in leukemic cell lines following exposure to hypomethylating drugs in vitro. SGI-110 is a novel hypomethylating dinucleotide with prolonged in vivo exposure and clinical activity in patients with MDS and AML. We demonstrate that this agent, like decitabine, produces robust re-expression of the CTAs NY-ESO-1 and MAGE-A, both in vitro and in leukemia-bearing AML xenografts. Upregulation of these genes in vitro was sufficient to induce cytotoxicity by HLA-compatible CD8+ T-cells specific for NY-ESO-1, a well-recognized and immunogenic CTA. Additionally, exposure to SGI-110 enhances MHC class I and co-stimulatory molecule expression, potentially contributing to recognition of CTAs. SGI-110, like the parent compound decitabine, induces expression of CTAs and might modulate immune recognition of myeloid malignancy. PMID:25260825

  3. Simultaneous operation and control of about 100 telescopes for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Wegner, P.; Colomé, J.; Hoffmann, D.; Houles, J.; Köppel, H.; Lamanna, G.; Le Flour, T.; Lopatin, A.; Lyard, E.; Melkumyan, D.; Oya, I.; Panazol, L.-I.; Punch, M.; Schlenstedt, S.; Schmidt, T.; Stegmann, C.; Schwanke, U.; Walter, R.; Consortium, CTA

    2012-12-01

    The Cherenkov Telescope Array (CTA) project is an initiative to build the next generation ground-based very high energy (VHE) gamma-ray instrument. Compared to current imaging atmospheric Cherenkov telescope experiments CTA will extend the energy range and improve the angular resolution while increasing the sensitivity up to a factor of 10. With about 100 separate telescopes it will be operated as an observatory open to a wide astrophysics and particle physics community, providing a deep insight into the non-thermal high-energy universe. The CTA Array Control system (ACTL) is responsible for several essential control tasks supporting the evaluation and selection of proposals, as well as the preparation, scheduling, and finally the execution of observations with the array. A possible basic distributed software framework for ACTL being considered is the ALMA Common Software (ACS). The ACS framework follows a container component model and contains a high level abstraction layer to integrate different types of device. To achieve a low-level consolidation of connecting control hardware, OPC UA (OPen Connectivity-Unified Architecture) client functionality is integrated directly into ACS, thus allowing interaction with other OPC UA capable hardware. The CTA Data Acquisition System comprises the data readout of all cameras and the transfer of the data to a camera server farm, thereby using standard hardware and software technologies. CTA array control is also covering conceptions for a possible array trigger system and the corresponding clock distribution. The design of the CTA observations scheduler is introducing new algorithmic technologies to achieve the required flexibility.

  4. Use of cognitive task analysis to guide the development of performance-based assessments for intraoperative decision making.

    PubMed

    Pugh, Carla M; DaRosa, Debra A

    2013-10-01

    There is a paucity of performance-based assessments that focus on intraoperative decision making. The purpose of this article is to review the performance outcomes and usefulness of two performance-based assessments that were developed using cognitive task analysis (CTA) frameworks. Assessment-A used CTA to create a "think aloud" oral examination that was administered while junior residents (PGY 1-2's, N = 69) performed a porcine-based laparoscopic cholecystectomy. Assessment-B used CTA to create a simulation-based, formative assessment of senior residents' (PGY 4-5's, N = 29) decision making during a laparoscopic ventral hernia repair. In addition to survey-based assessments of usefulness, a multiconstruct evaluation was performed using eight variables. When comparing performance outcomes, both approaches revealed major deficiencies in residents' intraoperative decision-making skills. Multiconstruct evaluation of the two CTA approaches revealed assessment method advantages for five of the eight evaluation areas: (1) Cognitive Complexity, (2) Content Quality, (3) Content Coverage, (4) Meaningfulness, and (5) Transfer and Generalizability. The two CTA performance assessments were useful in identifying significant training needs. While there are pros and cons to each approach, the results serve as a useful blueprint for program directors seeking to develop performance-based assessments for intraoperative decision making. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  5. Critical care physician cognitive task analysis: an exploratory study

    PubMed Central

    Fackler, James C; Watts, Charles; Grome, Anna; Miller, Thomas; Crandall, Beth; Pronovost, Peter

    2009-01-01

    Introduction For better or worse, the imposition of work-hour limitations on house-staff has imperiled continuity and/or improved decision-making. Regardless, the workflow of every physician team in every academic medical centre has been irrevocably altered. We explored the use of cognitive task analysis (CTA) techniques, most commonly used in other high-stress and time-sensitive environments, to analyse key cognitive activities in critical care medicine. The study objective was to assess the usefulness of CTA as an analytical tool in order that physician cognitive tasks may be understood and redistributed within the work-hour limited medical decision-making teams. Methods After approval from each Institutional Review Board, two intensive care units (ICUs) within major university teaching hospitals served as data collection sites for CTA observations and interviews of critical care providers. Results Five broad categories of cognitive activities were identified: pattern recognition; uncertainty management; strategic vs. tactical thinking; team coordination and maintenance of common ground; and creation and transfer of meaning through stories. Conclusions CTA within the framework of Naturalistic Decision Making is a useful tool to understand the critical care process of decision-making and communication. The separation of strategic and tactical thinking has implications for workflow redesign. Given the global push for work-hour limitations, such workflow redesign is occurring. Further work with CTA techniques will provide important insights toward rational, rather than random, workflow changes. PMID:19265517

  6. Critical care physician cognitive task analysis: an exploratory study.

    PubMed

    Fackler, James C; Watts, Charles; Grome, Anna; Miller, Thomas; Crandall, Beth; Pronovost, Peter

    2009-01-01

    For better or worse, the imposition of work-hour limitations on house-staff has imperiled continuity and/or improved decision-making. Regardless, the workflow of every physician team in every academic medical centre has been irrevocably altered. We explored the use of cognitive task analysis (CTA) techniques, most commonly used in other high-stress and time-sensitive environments, to analyse key cognitive activities in critical care medicine. The study objective was to assess the usefulness of CTA as an analytical tool in order that physician cognitive tasks may be understood and redistributed within the work-hour limited medical decision-making teams. After approval from each Institutional Review Board, two intensive care units (ICUs) within major university teaching hospitals served as data collection sites for CTA observations and interviews of critical care providers. Five broad categories of cognitive activities were identified: pattern recognition; uncertainty management; strategic vs. tactical thinking; team coordination and maintenance of common ground; and creation and transfer of meaning through stories. CTA within the framework of Naturalistic Decision Making is a useful tool to understand the critical care process of decision-making and communication. The separation of strategic and tactical thinking has implications for workflow redesign. Given the global push for work-hour limitations, such workflow redesign is occurring. Further work with CTA techniques will provide important insights toward rational, rather than random, workflow changes.

  7. Self-catalyzed photo-initiated RAFT polymerization for fabrication of fluorescent polymeric nanoparticles with aggregation-induced emission feature.

    PubMed

    Zeng, Guangjian; Liu, Meiying; Jiang, Ruming; Huang, Qiang; Huang, Long; Wan, Qing; Dai, Yanfeng; Wen, Yuanqing; Zhang, Xiaoyong; Wei, Yen

    2018-02-01

    In recent years, the fluorescent polymeric nanoparticles (FPNs) with aggregation-induced emission (AIE) feature have been extensively exploited in various biomedical fields owing to their advantages, such as low toxicity, biodegradation, excellent biocompatibility, good designability and optical properties. Therefore, development of a facile, efficient and well designable strategy should be of great importance for the biomedical applications of these AIE-active FPNs. In this work, a novel method for the fabrication of AIE-active FPNs has been developed through the self-catalyzed photo-initiated reversible addition fragmentation chain transfer (RAFT) polymerization using an AIE dye containing chain transfer agent (CTA), which could initiate the RAFT polymerization under light irradiation. The results suggested that the final AIE-active FPNs (named as TPE-poly(St-PEGMA)) showed great potential for biomedical applications owing to their optical and biological properties. More importantly, the method described in the work is rather simple and effective and can be further extended to prepare many other different AIE-active FPNs owing to the good monomer adoptability of RAFT polymerization. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Extragalactic photon-ALP conversion at CTA energies

    DOE PAGES

    Kartavtsev, A.; Raffelt, G.; Vogel, H.

    2017-01-12

    Magnetic fields in extragalactic space between galaxy clusters may induce conversions between photons and axion-like particles (ALPs), thereby shielding the photons from absorption on the extragalactic background light. For TeV gamma rays, the oscillation length (l osc) of the photon-ALP system becomes inevitably of the same order as the coherence length of the magnetic field l and the length over which the field changes significantly (transition length l t) due to refraction on background photons. We derive exact statistical evolution equations for the mean and variance of the photon and ALP transfer functions in the non-adiabatic regime (l osc ~more » l >> l t). We also make analytical predictions for the transfer functions in the quasi-adiabatic regime (l osc

  9. Artificial intelligence for the CTA Observatory scheduler

    NASA Astrophysics Data System (ADS)

    Colomé, Josep; Colomer, Pau; Campreciós, Jordi; Coiffard, Thierry; de Oña, Emma; Pedaletti, Giovanna; Torres, Diego F.; Garcia-Piquer, Alvaro

    2014-08-01

    The Cherenkov Telescope Array (CTA) project will be the next generation ground-based very high energy gamma-ray instrument. The success of the precursor projects (i.e., HESS, MAGIC, VERITAS) motivated the construction of this large infrastructure that is included in the roadmap of the ESFRI projects since 2008. CTA is planned to start the construction phase in 2015 and will consist of two arrays of Cherenkov telescopes operated as a proposal-driven open observatory. Two sites are foreseen at the southern and northern hemispheres. The CTA observatory will handle several observation modes and will have to operate tens of telescopes with a highly efficient and reliable control. Thus, the CTA planning tool is a key element in the control layer for the optimization of the observatory time. The main purpose of the scheduler for CTA is the allocation of multiple tasks to one single array or to multiple sub-arrays of telescopes, while maximizing the scientific return of the facility and minimizing the operational costs. The scheduler considers long- and short-term varying conditions to optimize the prioritization of tasks. A short-term scheduler provides the system with the capability to adapt, in almost real-time, the selected task to the varying execution constraints (i.e., Targets of Opportunity, health or status of the system components, environment conditions). The scheduling procedure ensures that long-term planning decisions are correctly transferred to the short-term prioritization process for a suitable selection of the next task to execute on the array. In this contribution we present the constraints to CTA task scheduling that helped classifying it as a Flexible Job-Shop Problem case and finding its optimal solution based on Artificial Intelligence techniques. We describe the scheduler prototype that uses a Guarded Discrete Stochastic Neural Network (GDSN), for an easy representation of the possible long- and short-term planning solutions, and Constraint Propagation techniques. A simulation platform, an analysis tool and different test case scenarios for CTA were developed to test the performance of the scheduler and are also described.

  10. Gadopentetate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning.

    PubMed

    Gupta, Atul K; Alberico, Ronald A; Litwin, Alan; Kanter, Peter; Grossman, Zachary D

    2002-01-01

    To demonstrate that gadopentetate dimeglumine is potentially an alternative contrast medium for computed tomographic angiography (CTA). One 12.2-kg Beagle dog was studied as proof of principle; the cervical vessels of three adult human patients were imaged for presurgical planning of the neck. Gadopentetate dimeglumine, 0.5 mol/l (Berlex Laboratories, Wayne, NJ, U.S.A.), a LightSpeed QX/i CT (General Electric Medical Systems, Milwaukee, WI, U.S.A.), and an Ultra Sparc II (SUN Microsystems, Santa Clara, CA, U.S.A.) running Advantage Windows 3.1 (General Electric Medical Systems) were used. Sufficient enhancement for CTA of the thoracic aorta, cervical vessels, and abdominal vessels was produced in the experimental dog, and the cervical vessels were clearly defined in all three patients. In that subset of patients with contraindications to iodinated contrast medium and for whom magnetic resonance angiography is inappropriate, gadopentetate dimeglumine may be an alternative contrast medium for CTA.

  11. Imaging techniques used in the diagnostic workup of acute venous thromboembolic disease.

    PubMed

    Tilve-Gómez, A; Rodríguez-Fernández, P; Trillo-Fandiño, L; Plasencia-Martínez, J M

    Early diagnosis is one of the most important factors affecting the prognosis of pulmonary embolism (PE); however, the clinical presentation of PE is often very unspecific and it can simulate other diseases. For these reasons, imaging tests, especially computed tomography angiography (CTA) of the pulmonary arteries, have become the keystone in the diagnostic workup of PE. The wide availability and high diagnostic performance of pulmonary CTA has led to an increase in the number of examinations done and a consequent increase in the population's exposure to radiation and iodinated contrast material. Thus, other techniques such as scintigraphy and venous ultrasonography of the lower limbs, although less accurate, continue to be used in certain circumstances, and optimized protocols have been developed for CTA to reduce the dose of radiation (by decreasing the kilovoltage) and the dose of contrast agents. We describe the technical characteristics and interpretation of the findings for each imaging technique used to diagnose PE and discuss their advantages and limitations; this knowledge will help the best technique to be chosen for each case. Finally, we comment on some data about the increased use of CTA, its clinical repercussions, its "overuse", and doubts about its cost-effectiveness. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Efficiency of High Molecular Weight Backbone Degradable HPMA Copolymer – Prostaglandin E1 Conjugate in Promotion of Bone Formation in Ovariectomized Rats

    PubMed Central

    Pan, Huaizhong; Sima, Monika; Miller, Scott C.; Kopečková, Pavla; Yang, Jiyuan; Kopeček, Jindřich

    2013-01-01

    Multiblock, high molecular weight, linear, backbone degradable HPMA copolymer-prostaglandin E1 (PGE1) conjugate has been synthesized by RAFT polymerization mediated by a new bifunctional chain transfer agent (CTA), which contains an enzymatically degradable oligopeptide sequence flanked by two dithiobenzoate groups, followed by post-polymerization aminolysis and thiol-ene chain extension. The multiblock conjugate contains Asp8 as the bone-targeting moiety and enzymatically degradable bonds in the polymer backbone; in vivo degradation produces cleavage products that are below the renal threshold. Using an ovariectomized (OVX) rat model, the accumulation in bone and efficacy to promote bone formation was evaluated; low molecular weight conjugates served as control. The results indicated a higher accumulation in bone, greater enhancement of bone density, and higher plasma osteocalcin levels for the backbone degradable conjugate. PMID:23731780

  13. Fabrication of polypyrrole-coated carbon nanotubes using oxidant-surfactant nanocrystals for supercapacitor electrodes with high mass loading and enhanced performance.

    PubMed

    Shi, Kaiyuan; Zhitomirsky, Igor

    2013-12-26

    A conceptually new approach to the fabrication of polypyrrole (PPy)-coated multiwalled carbon nanotubes (MWCNT) for application in electrodes of electrochemical supercapacitors (ES) is proposed. Cetrimonium persulfate (CTA)2S2O8 in the form of nanocrystals is used as an oxidant for the chemical polymerization of PPy. Ponceau S (PS) dye is investigated as a new anionic dopant. Testing results show that PS allows reduced PPy particle size and improved electrochemical performance, whereas (CTA)2S2O8 nanocrystals promote the formation of PPy nanofibers. We demonstrate for the first time that MWCNT can be efficiently dispersed using (CTA)2S2O8 nanocrystals. The analysis of the dispersion mechanism indicates that (CTA)2S2O8 dissociation is catalyzed by MWCNT. This new finding opens a new and promising strategy in MWCNT dispersion for colloidal processing of nanomaterials and electrophoretic nanotechnology. Uniformly coated MWCNT are obtained using (CTA)2S2O8 as a dispersant for MWCNT and oxidant for PPy polymerization and utilizing advantages of PS as an efficient dopant and nanostructure controlling agent. The analysis of the testing results provides an insight into the influence of PS molecular structure on PPy nanostructure and electrochemical properties. The PPy-coated MWCNT show superior electrochemical performance compared to PPy nanoparticles. The proof-of-principle is demonstrated by the fabrication of ES electrodes with excellent electrochemical performance at high active material loadings, good capacitance retention at high charge-discharge rates, and excellent cycling stability.

  14. Ferumoxytol MRA for transcatheter aortic valve replacement planning with renal insufficiency.

    PubMed

    Kallianos, Kimberly; Henry, Travis S; Yeghiazarians, Yerem; Zimmet, Jeffrey; Shunk, Kendrick A; Tseng, Elaine E; Mahadevan, Vaikom; Hope, Michael D

    2017-03-15

    Computed tomography angiography (CTA) is the test of choice for pre-procedure imaging of transcatheter aortic valve replacement (TAVR) candidates. The iodinated contrast required, however, increases the risk of renal dysfunction in patients with pre-existing renal failure. Ferumoxytol is a magnetic resonance imaging (MRI) contrast agent that can be used with renal failure. Its long vascular resonance time allows gated MRA sequences that approach CTA in image quality. We present respiratory and cardiac gated MRA enabled by ferumoxytol that can be post-processed in an analogous fashion to CTA. Seven patients with renal failure presenting for TAVR were imaged with respiratory and cardiac gated MRA at 3T using ferumoxtyol for contrast. Aortic annulus, root and peripheral access dimensions were calculated in a fashion identical to that used for CTA. Of these, 6 patients underwent a TAVR procedure and 5 had intraoperative valve assessment with transesophageal echocardiograph (TEE) using standard clinical protocols that employed both two- and three-dimensional techniques. Good correlation between MRA aortic annulus measurements and those from TEE were shown in 5 patients with mean annulus area of 392.4mm 2 (290-470 range) versus 374.1mm 2 (285-440 range), with a pairwise correlation coefficient of 0.92, p=0.029. All patients received Sapien valve implants (one 20mm, three 23mm, and two 26mm valves). Access decisions were guided by MRA with no complications. Annulus sizing resulted in no greater than trace/mild aortic regurgitation in all patients. Ferumoxytol MRA is a safe alternative to CTA in patients with renal failure for pre-TAVR analysis of the aortic root and peripheral access. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Low thermal budget annealing technique for high performance amorphous In-Ga-ZnO thin film transistors

    NASA Astrophysics Data System (ADS)

    Shin, Joong-Won; Cho, Won-Ju

    2017-07-01

    In this paper, we investigate a low thermal budget post-deposition-annealing (PDA) process for amorphous In-Ga-ZnO (a-IGZO) oxide semiconductor thin-film-transistors (TFTs). To evaluate the electrical characteristics and reliability of the TFTs after the PDA process, microwave annealing (MWA) and rapid thermal annealing (RTA) methods were applied, and the results were compared with those of the conventional annealing (CTA) method. The a-IGZO TFTs fabricated with as-deposited films exhibited poor electrical characteristics; however, their characteristics were improved by the proposed PDA process. The CTA-treated TFTs had excellent electrical properties and stability, but the CTA method required high temperatures and long processing times. In contrast, the fabricated RTA-treated TFTs benefited from the lower thermal budget due to the short process time; however, they exhibited poor stability. The MWA method uses a low temperature (100 °C) and short annealing time (2 min) because microwaves transfer energy directly to the substrate, and this method effectively removed the defects in the a-IGZO TFTs. Consequently, they had a higher mobility, higher on-off current ratio, lower hysteresis voltage, lower subthreshold swing, and higher interface trap density than TFTs treated with CTA or RTA, and exhibited excellent stability. Based on these results, low thermal budget MWA is a promising technology for use on various substrates in next generation displays.

  16. A unique role of the cholera toxin A1-DD adjuvant for long-term plasma and memory B cell development.

    PubMed

    Bemark, Mats; Bergqvist, Peter; Stensson, Anneli; Holmberg, Anna; Mattsson, Johan; Lycke, Nils Y

    2011-02-01

    Adjuvants have traditionally been appreciated for their immunoenhancing effects, whereas their impact on immunological memory has largely been neglected. In this paper, we have compared three mechanistically distinct adjuvants: aluminum salts (Alum), Ribi (monophosphoryl lipid A), and the cholera toxin A1 fusion protein CTA1-DD. Their influence on long-term memory development was dramatically different. Whereas a single immunization i.p. with 4-hydroxy-3-nitrophenyl acetyl (NP)-chicken γ-globulin and adjuvant stimulated serum anti-NP IgG titers that were comparable at 5 wk, CTA1-DD-adjuvanted responses were maintained for >16 mo with a half-life of anti-NP IgG ∼36 wk, but <15 wk after Ribi or Alum. A CTA1-DD dose-dependent increase in germinal center (GC) size and numbers was found, with >60% of splenic B cell follicles hosting GC at an optimal CTA1-DD dose. Roughly 7% of these GC were NP specific. This GC-promoting effect correlated well with the persistence of long-term plasma cells in the bone marrow and memory B cells in the spleen. CTA1-DD also facilitated increased somatic hypermutation and affinity maturation of NP-specific IgG Abs in a dose-dependent fashion, hence arguing that large GC not only promotes higher Ab titers but also high-quality Ab production. Adoptive transfer of splenic CD80(+), but not CD80(-), B cells, at 1 y after immunization demonstrated functional long-term anti-NP IgG and IgM memory cells. To our knowledge, this is the first report to specifically compare and document that adjuvants can differ considerably in their support of long-term immune responses. Differential effects on the GC reaction appear to be the basis for these differences.

  17. Added value of delayed computed tomography angiography in primary intracranial hemorrhage and hematoma size for predicting spot sign.

    PubMed

    Wu, Te Chang; Chen, Tai Yuan; Shiue, Yow Ling; Chen, Jeon Hor; Hsieh, Tsyh-Jyi; Ko, Ching Chung; Lin, Ching Po

    2018-04-01

    Background The computed tomography angiography (CTA) spot sign represents active contrast extravasation within acute primary intracerebral hemorrhage (ICH) and is an independent predictor of hematoma expansion (HE) and poor clinical outcomes. The spot sign could be detected on first-pass CTA (fpCTA) or delayed CTA (dCTA). Purpose To investigate the additional benefits of dCTA spot sign in primary ICH and hematoma size for predicting spot sign. Material and Methods This is a retrospective study of 100 patients who underwent non-contrast CT (NCCT) and CTA within 24 h of onset of primary ICH. The presence of spot sign on fpCTA or dCTA, and hematoma size on NCCT were recorded. The spot sign on fpCTA or dCTA for predicting significant HE, in-hospital mortality, and poor clinical outcomes (mRS ≥ 4) are calculated. The hematoma size for prediction of CTA spot sign was also analyzed. Results Only the spot sign on dCTA could predict high risk of significant HE and poor clinical outcomes as on fpCTA ( P < 0.05). With dCTA, there is increased sensitivity and negative predictive value (NPV) for predicting significant HE, in-hospital mortality, and poor clinical outcomes. The XY value (product of the two maximum perpendicular axial dimensions) is the best predictor (area under the curve [AUC] = 0.82) for predicting spot sign on fpCTA or dCTA in the absence of intraventricular and subarachnoid hemorrhage. Conclusion This study clarifies that dCTA imaging could improve predictive performance of CTA in primary ICH. Furthermore, the XY value is the best predictor for CTA spot sign.

  18. Maltopentaose-conjugated CTA for RAFT polymerization generating nanostructured bioresource-block copolymer.

    PubMed

    Togashi, Daichi; Otsuka, Issei; Borsali, Redouane; Takeda, Koichi; Enomoto, Kazushi; Kawaguchi, Seigou; Narumi, Atsushi

    2014-12-08

    We now describe the synthesis of a new family of oligosaccharide-conjugated functional molecules, which act as chain transfer agents (CTAs) for the reversible addition-fragmentation chain transfer (RAFT) polymerization. The synthesis was started from the catalyst-free direct N-glycosyl reaction of 5-azidopentylamine onto maltopentaose (Mal5) in dry methanol at room temperature and subsequent N-protected reaction with acetic anhydride, producing a stable oligosaccharide-building block, such as Mal5 with an azidopentyl group (Mal5-N3). The azido group was hydrogenated using platinum dioxide (PtO2) as a catalyst to give Mal5 with aminopentyl group (Mal5-NH2), which was then reacted with CTA molecules bearing activated ester moieties. These reactions produced Mal5-modified macro-CTAs (Mal5-CTAs, 1), which were used for the RAFT polymerizations of styrene (St) and methyl methacrylate (MMA) in DMF. The polymerizations were performed using the [M]0/[1]0 values ranging from 50 to 600, affording the Mal5-hybrid amphiphilic block copolymers (BCPs), such as Mal5-polystyrene (2) and Mal5-poly(methyl methacrylate) (3), with a quantitative end-functionality and the controlled molecular weights between 4310 and 20 300 g mol(-1). The small-angle X-ray scattering (SAXS) measurements were accomplished for 2 and 3 to ensure their abilities to form phase separated structures in their bulk states with the increasing temperatures from 30 to 190 °C. The featured results were observed for 2 (ϕMal5 = 0.14) and 3 (ϕMal5 = 0.16) at temperatures above 100 °C, where ϕMal5 denotes the volume fraction of the Mal5 unit in the BCP sample. For both BCP samples, the primary scattering peaks q* were clearly observed together with the higher-ordered scattering peaks √2q* and √3q*. Thus, these Mal5-hybrid amphiphilic BCP samples have a body centered cubic (BCC) phase morphology. The domain spacing (d) values of the BCC morphology for 2 (ϕMal5 = 0.14) and 3 (ϕMal5 = 0.16) were 10.4 and 9.55 nm, respectively, which were determined using Bragg's relation (d = 2π/q*). The present RAFT agents were shown to eventually provide the phase separated structural polymeric materials in which 5.4 nm bioresource-spherical domains were periodically arrayed at the interval of about 10 nm.

  19. Side-chain amino-acid-based pH-responsive self-assembled block copolymers for drug delivery and gene transfer.

    PubMed

    Kumar, Sonu; Acharya, Rituparna; Chatterji, Urmi; De, Priyadarsi

    2013-12-10

    Developing safe and effective nanocarriers for multitype of delivery system is advantageous for several kinds of successful biomedicinal therapy with the same carrier. In the present study, we have designed amino acid biomolecules derived hybrid block copolymers which can act as a promising vehicle for both drug delivery and gene transfer. Two representative natural chiral amino acid-containing (l-phenylalanine and l-alanine) vinyl monomers were polymerized via reversible addition-fragmentation chain transfer (RAFT) process in the presence of monomethoxy poly(ethylene glycol) based macro-chain transfer agents (mPEGn-CTA) for the synthesis of well-defined side-chain amino-acid-based amphiphilic block copolymers, monomethoxy poly(ethylene glycol)-b-poly(Boc-amino acid methacryloyloxyethyl ester) (mPEGn-b-P(Boc-AA-EMA)). The self-assembled micellar aggregation of these amphiphilic block copolymers were studied by fluorescence spectroscopy, atomic force microscopy (AFM) and scanning electron microscopy (SEM). Potential applications of these hybrid polymers as drug carrier have been demonstrated in vitro by encapsulation of nile red dye or doxorubicin drug into the core of the micellar nanoaggregates. Deprotection of side-chain Boc- groups in the amphiphilic block copolymers subsequently transformed them into double hydrophilic pH-responsive cationic block copolymers having primary amino groups in the side-chain terminal. The DNA binding ability of these cationic block copolymers were further investigated by using agarose gel retardation assay and AFM. The in vitro cytotoxicity assay demonstrated their biocompatible nature and these polymers can serve as "smart" materials for promising bioapplications.

  20. Commercial Refrigeration: Heat Transfer Optimization and Energy Reduction, Measurement and Verification of a Liquid Refrigerant Pump System Retrofit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaul, Chris; Sheppy, Michael

    This study describes the test results of a Refrigerant Pump System integrated into a commercial supermarket direct expansion (DX) vapor compression refrigeration system. The Liquid Refrigerant Pump System retrofit (patent-pending; application number 13/964,198) was introduced to NREL in August 2014 by CTA Architects Engineers.

  1. Esmolol is noninferior to metoprolol in achieving a target heart rate of 65 beats/min in patients referred to coronary CT angiography: a randomized controlled clinical trial.

    PubMed

    Maurovich-Horvat, Pál; Károlyi, Mihály; Horváth, Tamás; Szilveszter, Bálint; Bartykowszki, Andrea; Jermendy, Ádám L; Panajotu, Alexisz; Celeng, Csilla; Suhai, Ferenc I; Major, Gyöngyi P; Csobay-Novák, Csaba; Hüttl, Kálmán; Merkely, Béla

    2015-01-01

    Coronary CT angiography (CTA) is an established tool to rule out coronary artery disease. Performance of coronary CTA is highly dependent on patients' heart rates (HRs). Despite widespread use of β-blockers for coronary CTA, few studies have compared various agents used to achieve adequate HR control. We sought to assess if the ultrashort-acting β-blocker intravenous esmolol is at least as efficacious as the standard of care intravenous metoprolol for HR control during coronary CTA. Patients referred to coronary CTA with a HR >65 beats/min despite oral metoprolol premedication were enrolled in the study. We studied 412 patients (211 male; mean age, 57 ± 12 years). Two hundred four patients received intravenous esmolol, and 208 received intravenous metoprolol with a stepwise bolus administration protocol. HR and blood pressure were recorded at arrival, before, during, immediately after, and 30 minutes after the coronary CTA scan. Mean HRs of the esmolol and metoprolol groups were similar at arrival (78 ± 13 beats/min vs 77 ± 12 beats/min; P = .65) and before scan (68 ± 7 beats/min vs 69 ± 7 beats/min; P = .60). However, HR during scan was lower in the esmolol group vs the metoprolol group (58 ± 6 beats/min vs 61 ± 7 beats/min; P < .0001), whereas HRs immediately and 30 minutes after the scan were higher in the esmolol group vs the metoprolol group (68 ± 7 beats/min vs 66 ± 7 beats/min; P = .01 and 65 ± 8 beats/min vs 63 ± 8 beats/min; P < .0001; respectively). HR ≤ 65 beats/min was reached in 182 of 204 patients (89%) who received intravenous esmolol vs 162 of 208 of the patients (78%) who received intravenous metoprolol (P < .05). Of note, hypotension (systolic BP <100 mm Hg) was observed right after the scan in 19 patients (9.3%) in the esmolol group and in 8 patients (3.8%) in the metoprolol group (P < .05), whereas only 5 patients (2.5%) had hypotension 30 minutes after the scan in the esmolol group compared to 8 patients (3.8%) in the metoprolol group (P = .418). Intravenous esmolol with a stepwise bolus administration protocol is at least as efficacious as the standard of care intravenous metoprolol for HR control in patients who undergo coronary CTA. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  2. The use of cognitive task analysis to improve the learning of percutaneous tracheostomy placement.

    PubMed

    Sullivan, Maura E; Brown, Carlos V R; Peyre, Sarah E; Salim, Ali; Martin, Matthew; Towfigh, Shirin; Grunwald, Tiffany

    2007-01-01

    The purpose of the current study was to determine the effectiveness of using cognitive task analysis (CTA) to develop a curriculum to teach the behavioral skills and the cognitive strategies of a percutaneous tracheostomy (PT) placement. Postgraduate 2, 3, and 4 general surgery residents were randomly assigned to either the CTA group (N = 9) or the control group (N = 11). The CTA group was taught percutaneous tracheostomy placement using the CTA curriculum. The control group received the traditional curriculum. The CTA group performed significantly higher on the PT procedure at 1 month (CTA: 43.5 +/- 3.7, control 35.2 +/- 3.9, P = .001) and at 6 months post-instruction (CTA: 39.4 +/- 4.2, control: 31.8 +/- 5.8, P = .004). In addition, the CTA group demonstrated superior cognitive strategies than the control group (CTA: 25.4 +/- 5.3, control: 19.2 +/- 2.0, P = .004). The use of CTA was effective in improving the cognitive processes and technical skills of performing a PT for surgical residents.

  3. Novel hybrid materials based on the vanadium oxide nanobelts

    NASA Astrophysics Data System (ADS)

    Zabrodina, G. S.; Makarov, S. G.; Kremlev, K. V.; Yunin, P. A.; Gusev, S. A.; Kaverin, B. S.; Kaverina, L. B.; Ketkov, S. Yu.

    2016-04-01

    Novel hybrid materials based on zinc phthalocyanine and nanostructured vanadium oxides have attracted extensive attention for the development of academic research and innovative industrial applications such as flexible electronics, optical sensors and heterogeneous catalysts. Vanadium oxides nanobelts were synthesized via a hydrothermal treatment V2O5·nH2O gel with surfactants (TBAB, CTAB) used as structure-directing agents, where CTAB - cetyltrimethylammonium bromide, TBAB - tetrabutylammonium bromide. Hybrid materials were prepared decoration of (CTA)0.33V2O5 flexible nanobelts with cationic zinc phthalocyanine by the ion-exchange route. Investigations of the thermal stability, morphologies and structures of the (CTA)0.33V2O5, (TBA)0.16V2O5 nanobelts and zinc phthalocyanine exchange product were carried out. The hybrid materials based on the nanostructured vanadium oxide and zinc phthalocyanine were tested as photocatalysts for oxidation of citronellol and 2-mercaptoethanol by dioxygen.

  4. Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

    PubMed

    Ott, Sabine; Gölitz, Philipp; Adamek, Edyta; Royalty, Kevin; Doerfler, Arnd; Struffert, Tobias

    2015-08-01

    We compared flat-detector computed tomography angiography (FD-CTA) to multislice computed tomography (MS-CTA) and digital subtracted angiography (DSA) for the visualization of experimental aneurysms treated with stents, coils or a combination of both.In 20 rabbits, aneurysms were created using the rabbit elastase aneurysm model. Seven aneurysms were treated with coils, seven with coils and stents, and six with self-expandable stents alone. Imaging was performed by DSA, MS-CTA and FD-CTA immediately after treatment. Multiplanar reconstruction (MPR) was performed and two experienced reviewers compared aneurysm/coil package size, aneurysm occlusion, stent diameters and artifacts for each modality.In aneurysms treated with stents alone, the visualization of the aneurysms was identical in all three imaging modalities. Residual aneurysm perfusion was present in two cases and visible in DSA and FD-CTA but not in MS-CTA. The diameter of coil-packages was overestimated in MS-CT by 56% and only by 16% in FD-CTA compared to DSA (p < 0.05). The diameter of stents was identical for DSA and FD-CTA and was significantly overestimated in MS-CTA (p < 0.05). Beam/metal hardening artifacts impaired image quality more severely in MS-CTA compared to FD-CTA.MS-CTA is impaired by blooming and beam/metal hardening artifacts in the visualization of implanted devices. There was no significant difference between measurements made with noninvasive FD-CTA compared to gold standard of DSA after stenting and after coiling/stent-assisted coiling of aneurysms. FD-CTA may be considered as a non-invasive alternative to the gold standard 2D DSA in selected patients that require follow up imaging after stenting. © The Author(s) 2015.

  5. [Advantages and disadvantages of composite tissue allotransplantation].

    PubMed

    Yang, Yang; Lu, Binglun; Zhang, Hui; Xia, Wei; Yi, Chenggang; Guo, Shuzhong

    2009-12-01

    To review the research progress of composite tissue allotransplantation (CTA), analyze the superiority and the inferiority, and inform the possible direction of further research. Literature concerning CTA was reviewed and analyzed in terms of the limits of conventional reparative and reconstructive surgery, the definition of CTA, potential advantages, and treatment risks. The clinical research of CTA both at home and abroad proved that the therapeutic effect of CTA was better than that of conventional reparative and reconstructive surgery. However, the risks resulting from immunosuppressive therapy were still the primary factors restraining the wide clinical application of CTA. The development of immunosuppressive therapy explores a great development potential for the CTA, and how to decrease the treatment risk of immunosuppressive therapy will be the main research direction in the field of CTA.

  6. Comparative analysis of fluorescent angiography, computed tomographic angiography and magnetic resonance angiography for planning autologous breast reconstruction

    PubMed Central

    Chae, Michael P.; Hunter-Smith, David J.

    2015-01-01

    Background The high incidence of breast cancer and growing number of breast cancer patients undergoing mastectomy has led to breast reconstruction becoming an important part of holistic treatment for these patients. In planning autologous reconstructions, preoperative assessment of donor site microvascular anatomy with advanced imaging modalities has assisted in the appropriate selection of flap donor site, individual perforators, and lead to an overall improvement in flap outcomes. In this review, we compare the accuracy of fluorescent angiography, computed tomographic angiography (CTA), and magnetic resonance angiography (MRA) and their impact on clinical outcomes. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE was undertaken. Results Fluorescent angiography is technically limited by its inability to evaluate deep-lying perforators and hence, it has a minimal role in the preoperative setting. However, it may be useful intraoperatively in evaluating microvascular anastomotic patency and the mastectomy skin perfusion. CTA is currently widely considered the standard, due to its high accuracy and reliability. Multiple studies have demonstrated its ability to improve clinical outcomes, such as operative length and flap complications. However, concerns surrounding exposure to radiation and nephrotoxic contrast agents exist. MRA has been explored, however despite recent advances, the image quality of MRA is considered inferior to CTA. Conclusions Preoperative imaging is an essential component in planning autologous breast reconstruction. Fluorescent angiography presents minimal role as a preoperative imaging modality, but may be a useful intraoperative adjunct to assess the anastomosis and the mastectomy skin perfusion. Currently, CTA is the gold standard preoperatively. MRA has a role, particularly for women of younger age, iodine allergy, and renal impairment. PMID:26005648

  7. Nonenhanced MR angiography of the pulmonary arteries using single-shot radial quiescent-interval slice-selective (QISS): a technical feasibility study.

    PubMed

    Edelman, Robert R; Silvers, Robert I; Thakrar, Kiran H; Metzl, Mark D; Nazari, Jose; Giri, Shivraman; Koktzoglou, Ioannis

    2017-06-30

    For evaluation of the pulmonary arteries in patients suspected of pulmonary embolism, CT angiography (CTA) is the first-line imaging test with contrast-enhanced MR angiography (CEMRA) a potential alternative. Disadvantages of CTA include exposure to ionizing radiation and an iodinated contrast agent, while CEMRA is sensitive to respiratory motion and requires a gadolinium-based contrast agent. The primary goal of our technical feasibility study was to evaluate pulmonary arterial conspicuity using breath-hold and free-breathing implementations of a recently-developed nonenhanced approach, single-shot radial quiescent-interval slice-selective (QISS) MRA. Breath-hold and free-breathing, navigator-gated versions of radial QISS MRA were evaluated at 1.5 Tesla in three healthy subjects and 11 patients without pulmonary embolism or arterial occlusion by CTA. Images were scored by three readers for conspicuity of the pulmonary arteries through the level of the segmental branches. In addition, one patient with pulmonary embolism was imaged. Scan time for a 54-slice acquisition spanning the pulmonary arteries was less than 2 minutes for breath-hold QISS, and less than 3.4 min using free-breathing QISS. Pulmonary artery branches through the segmental level were conspicuous with either approach. Free-breathing scans showed only mild blurring compared with breath-hold scans. For both readers, less than 1% of pulmonary arterial segments were rated as "not seen" for breath-hold and navigator-gated QISS, respectively. In subjects with atrial fibrillation, single-shot radial QISS consistently depicted the pulmonary artery branches, whereas navigator-gated 3D balanced steady-state free precession showed motion artifacts. In one patient with pulmonary embolism, radial QISS demonstrated central pulmonary emboli comparably to CEMRA and CTA. The thrombi were highly conspicuous on radial QISS images, but appeared subtle and were not prospectively identified on scout images acquired using a single-shot bSSFP acquisition. In this technical feasibility study, both breath-hold and free-breathing single-shot radial QISS MRA enabled rapid, consistent demonstration of the pulmonary arteries through the level of the segmental branches, with only minimal artifacts from respiratory motion and cardiac arrhythmias. Based on these promising initial results, further evaluation in patients with suspected pulmonary embolism appears warranted.

  8. CT angiography - chest

    MedlinePlus

    ... aortic aneurysm - CTA chest; Venous thromboembolism - CTA lung; Blood clot - CTA lung; Embolus - CTA lung; CT pulmonary angiogram ... angiogram may be done: For symptoms that suggest blood clots in the lungs, such as chest pain, rapid ...

  9. Development of Medical Technology for Contingency Response to Marrow Toxic Agents

    DTIC Science & Technology

    2014-07-25

    Research in Transplantation : Create a platform that facilitates multicenter collaboration and data management. 15. SUBJECT TERMS Research in HLA ...Confirmatory Testing OTTR Organ Transplant Tracking Record CTA Clinical Trial Application P2P Peer-to-Peer PBMC Peripheral Blood Mononuclear Cells...NUMBER Project 1, 2, 3, 4 5f. WORK UNIT NUMBER N/A 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) National Marrow Donor Program 3001

  10. Long non-coding RNA CTA sensitizes osteosarcoma cells to doxorubicin through inhibition of autophagy

    PubMed Central

    Wang, Zhengguang; Liu, Zhendong; Wu, Song

    2017-01-01

    Recently, several long non-coding RNAs (lncRNAs) have been implicated in osteosarcoma (OS). However, the regulatory roles of lncRNAs in chemotherapy resistance of OS still remain unclear. This study aimed to screen a novel lncRNA that contributes to chemotherapeutic resistance of OS, and to explore the underlying mechanisms. Our data showed that lncRNA CTA was markedly downregulated in OS tissues compared to their matched non-tumor tissues, and low expression of lncRNA CTA was significantly associated with the advanced clinical stage and tumor size. In addition, OS patients with low lncRNA CTA levels showed a worse prognosis when compared with those with high expression of lncRNA CTA. Furthermore, we report that lncRNA CTA has an inverse relationship with miR-210 expression in OS tissues. LncRNA CTA could be activated by doxorubicin (DOX), and could promote OS cell apoptosis by competitively binding miR-210, while inhibit cell autophagy. On the other hand, lncRNA CTA was downregulated in DOX-resistant OS cells. Overexpression of lncRNA CTA reduced autophagy and subsequently overcame DOX resistance of OS in vitro and in vivo. Therefore, we demonstrate that lncRNA CTA is an essential regulator in DOX-induced OS cell apoptosis, and the lncRNA CTA-miR-210 axis plays an important role in reducing OS chemoresistance. PMID:28415557

  11. Gadolinium-enhanced computed tomographic angiography: current status.

    PubMed

    Rosioreanu, Alex; Alberico, Ronald A; Litwin, Alan; Hon, Man; Grossman, Zachary D; Katz, Douglas S

    2005-01-01

    This article reviews the research to date, as well as our clinical experience from two institutions, on gadolinium-enhanced computed tomographic angiography (gCTA) for imaging the body. gCTA may be an appropriate examination for the small percentage of patients who would benefit from noninvasive vascular imaging, but who have contraindications to both iodinated contrast and magnetic resonance imaging. gCTA is more expensive than CTA with iodinated contrast, due to the dose of gadolinium administered, and gCTA has limitations compared with CTA with iodinated contrast, in that parenchymal organs are not optimally enhanced at doses of 0.5 mmol/kg or lower. However, in our experience, gCTA has been a very useful problem-solving examination in carefully selected patients. With the advent of 16-64 detector CT, in combination with bolus tracking, we believe that the overall dose of gadolinium needed for diagnostic CTA examinations, while relatively high, can be safely administered.

  12. Hexadecyltrimethylammonium bromide (CTA-Br) and 1-butyl-3-methylimidazolium tetrafluoroborate (bmim-BF4) in aqueous solution: An ephemeral binary system.

    PubMed

    Comelles, Francesc; Ribosa, Isabel; Gonzalez, Juan José; Garcia, M Teresa

    2017-03-15

    Mixtures of the cationic surfactant hexadecyltrimethylammonium bromide (CTA-Br) and the ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate (bmim-BF 4 ) in aqueous solutions are expected to behave as typical binary cationic surfactant system taking into account the surface activity displayed by the ionic liquid, instead of considering the IL as a water cosolvent. Surface tension and conductivity measurements have been conducted as a function of the total concentration of the mixtures at different surfactant mole fraction (α CTA-Br ) to investigate the surface active properties. Turbidity immediately appearing when the compounds are mixed in water suggests the spontaneous formation of the low soluble compound hexadecyltrimethylammonium tetrafluoroborate (CTA-BF 4 ), together with the salt formed by the respective counterions bmim + and Br - in solution. For α CTA-Br ≠0.5, furthermore of the mentioned compounds, the spare bmim-BF 4 (for α CTA-Br <0.5) or CTA-Br (for α CTA-Br >0.5), are also present in the aqueous solution. Systems containing excess of bmim-BF 4 show a low critical aggregate concentration (cac), but an unexpected high surface tension at cac (γ cac ≈53-56mN/m), as pure CTA-BF 4 . For systems containing excess of CTA-Br, cac increases but γ cac decreases up to 36mN/m. Mixtures of pure CTA-BF 4 and bmim-BF 4 or CTA-Br behave as typical binary surfactant systems. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG-gating

    PubMed Central

    Manna, Carmelinda; Silva, Mario; Cobelli, Rocco; Poggesi, Sara; Rossi, Cristina; Sverzellati, Nicola

    2017-01-01

    PURPOSE We aimed to perform intraindividual comparison of computed tomography (CT) parameters, image quality, and radiation exposure between standard CT angiography (CTA) and high-pitch dual source (DS)-CTA, in subjects undergoing serial CTA of thoracoabdominal aorta. METHODS Eighteen subjects with thoracoabdominal CTA by standard technique and high-pitch DS-CTA technique within 6 months of each other were retrieved for intraindividual comparison of image quality in thoracic and abdominal aorta. Quantitative analysis was performed by comparison of mean aortic attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Qualitative analysis was performed by visual assessment of motion artifacts and diagnostic confidence. Radiation exposure was quantified by effective dose. Image quality was apportioned to radiation exposure by means of figure of merit. RESULTS Mean aortic attenuation and noise were higher in high-pitch DS-CTA of thoracoabdominal aorta, whereas SNR and CNR were similar in thoracic aorta and significantly lower in high-pitch DS-CTA of abdominal aorta (P = 0.024 and P = 0.016). High-pitch DS-CTA was significantly better in the first segment of thoracic aorta. Effective dose was reduced by 72% in high-pitch DS-CTA. CONCLUSION High-pitch DS-CTA without electrocardiography-gating is an effective technique for imaging aorta with very low radiation exposure and with significant reduction of motion artifacts in ascending aorta; however, the overall quality of high-pitch DS-CTA in abdominal aorta is lower than standard CTA. PMID:28703104

  14. Acquisition and retrieval of conditioned taste aversion is impaired by brain damage caused by two hours of pilocarpine-induced status epilepticus.

    PubMed

    Sroubek, J; Hort, J; Komárek, V; Langmeier, M; Brozek, G

    2001-01-01

    The effect of Cavalheiro's pilocarpine model of epileptogenesis upon conditioned taste aversion (CTA), an important example of nondeclarative memory, was studied in adult Long Evans rats. Deterioration of CTA was studied during the silent period between pilocarpine-induced status epilepticus (SE) and delayed spontaneous recurrent seizures. SE was elicited by i.p. injection of pilocarpine (320 mg/kg ) and interrupted after 2 hours by clonazepame (1 mg/kg i.p.). Peripheral cholinergic symptoms were suppressed by methylscopolamine (1 mg/kg i.p.), administered together with pilocarpine. CTA was formed against the salty taste of isotonic LiCl. In the experiment of CTA acquisition, the CTA was formed and tested during the silent period after SE. In the experiment of CTA retrieval, the CTA was acquired before SE and the retrieval itself was tested during the silent period. Retrieval of CTA acquired before SE was impaired more than the retrieval of CTA formed during the silent period. Our findings indicate that epileptic seizures can disrupt even non-declarative memory but that CTA formed by the damaged brain can use its better preserved parts for memory trace formation. Ketamine (50 mg/kg i.p.) applied 2 min after the onset of pilocarpine-induced status epilepticus protected memory deterioration.

  15. Assessment of vascular invasion by bone and soft tissue tumours of the limbs: usefulness of MDCT angiography.

    PubMed

    Thévenin, Fabrice S; Drapé, Jean-Luc; Biau, David; Campagna, Raphaël; Richarme, Delphine; Guerini, Henri; Chevrot, Alain; Larousserie, Frédérique; Babinet, Antoine; Anract, Philippe; Feydy, Antoine

    2010-06-01

    To evaluate the accuracy of computed tomography angiography (CTA) in predicting arterial encasement by limb tumours, by comparing CTA with surgical findings (gold standard). Preoperative CTA images of 55 arteries in 48 patients were assessed for arterial status: cross-sectional CTA images were scored as showing a fat plane between artery and tumour (score 0), slight contact between artery and tumour (score 1), partial arterial encasement (score 2) or total arterial encasement (score 3). Reformatted CTA images were assessed for arterial displacement, rigid wall, stenosis or occlusion. At surgery, arteries were classified as free or surgically encased; 45 arteries were free and 10 were surgically encased. Multivariate logistic regression identified the axial CTA score as a relevant predictor for arterial encasement and subsequent vascular intervention during surgery. All sites where CTA showed a fat plane between the tumour and the artery were classified as free at surgery (n = 28/28). The sensitivity of total arterial encasement on CTA (score 3) was 90%, specificity 93%, accuracy 93% and positive likelihood ratio 13.5. CTA evidence of total arterial encasement is a highly specific indication of arterial encasement. The presence of fat between the tumour and the artery on CTA rules out arterial involvement at surgery.

  16. Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.

    PubMed

    Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L

    2018-06-01

    Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.

  17. ECG-gated imaging of the left atrium and pulmonary veins: Intra-individual comparison of CTA and MRA.

    PubMed

    Fahlenkamp, U L; Lembcke, A; Roesler, R; Schwenke, C; Huppertz, A; Streitparth, F; Taupitz, M; Hamm, B; Wagner, M

    2013-10-01

    To compare electrocardiography (ECG)-gated computed tomography angiography (CTA) with ECG-gated magnetic resonance angiography (MRA) for assessment of the left atrium (LA) and pulmonary veins (PVs). Twenty-nine consecutive patients who underwent both cardiac CTA and MRA were evaluated. Contrast-enhanced CTA was performed with prospective ECG-gating using a 320 detector row CT system. Contrast-enhanced MRA was performed with prospective ECG-gating using a 1.5 T MRI system equipped with a 32 channel cardiac coil. MRA was acquired during free-breathing with a navigator-gated inversion-recovery prepared steady-state free precession sequence. Two readers independently assessed the CTA and MRA images for vascular definition of the PVs (from 0, not visualized, to 4, excellent definition) and ostial PV diameters. Variants of LA anatomy were assessed in consensus. CTA was successfully performed in all patients with a mean radiation exposure of 5.1 ± 2.2 mSv. MRA was successfully performed in 27 of 29 patients (93 %). Visual definition of PVs was rated significantly higher on CTA compared to MRA (p < 0.0001; reader 1: excellent/good ratings of CTA versus MRA: 100% versus 86%; reader 2: excellent/good ratings of CTA versus MRA: 99% versus 89%). Assessment of ostial PV diameters showed good correlation between CTA and MRA (reader 1: Pearson r = 0.91; reader 2: Pearson r = 0.82). Moreover, agreement between both imaging methods for evaluation of variants of LA anatomy was high (agreement rate of 95% (95% CI: 92-99%). ECG-gated CTA provides higher image quality compared to ECG-gated MRA. Nevertheless, both CTA and MRA provided similar information of LA anatomy and ostial PV diameters. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  19. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  20. Facile Synthesis of Worm-like Micelles by Visible Light Mediated Dispersion Polymerization Using Photoredox Catalyst

    PubMed Central

    Yeow, Jonathan; Xu, Jiangtao; Boyer, Cyrille

    2016-01-01

    Presented herein is a protocol for the facile synthesis of worm-like micelles by visible light mediated dispersion polymerization. This approach begins with the synthesis of a hydrophilic poly(oligo(ethylene glycol) methyl ether methacrylate) (POEGMA) homopolymer using reversible addition-fragmentation chain-transfer (RAFT) polymerization. Under mild visible light irradiation (λ = 460 nm, 0.7 mW/cm2), this macro-chain transfer agent (macro-CTA) in the presence of a ruthenium based photoredox catalyst, Ru(bpy)3Cl2 can be chain extended with a second monomer to form a well-defined block copolymer in a process known as Photoinduced Electron Transfer RAFT (PET-RAFT). When PET-RAFT is used to chain extend POEGMA with benzyl methacrylate (BzMA) in ethanol (EtOH), polymeric nanoparticles with different morphologies are formed in situ according to a polymerization-induced self-assembly (PISA) mechanism. Self-assembly into nanoparticles presenting POEGMA chains at the corona and poly(benzyl methacrylate) (PBzMA) chains in the core occurs in situ due to the growing insolubility of the PBzMA block in ethanol. Interestingly, the formation of highly pure worm-like micelles can be readily monitored by observing the onset of a highly viscous gel in situ due to nanoparticle entanglements occurring during the polymerization. This process thereby allows for a more reproducible synthesis of worm-like micelles simply by monitoring the solution viscosity during the course of the polymerization. In addition, the light stimulus can be intermittently applied in an ON/OFF manner demonstrating temporal control over the nanoparticle morphology. PMID:27340940

  1. Facile Synthesis of Worm-like Micelles by Visible Light Mediated Dispersion Polymerization Using Photoredox Catalyst.

    PubMed

    Yeow, Jonathan; Xu, Jiangtao; Boyer, Cyrille

    2016-06-08

    Presented herein is a protocol for the facile synthesis of worm-like micelles by visible light mediated dispersion polymerization. This approach begins with the synthesis of a hydrophilic poly(oligo(ethylene glycol) methyl ether methacrylate) (POEGMA) homopolymer using reversible addition-fragmentation chain-transfer (RAFT) polymerization. Under mild visible light irradiation (λ = 460 nm, 0.7 mW/cm(2)), this macro-chain transfer agent (macro-CTA) in the presence of a ruthenium based photoredox catalyst, Ru(bpy)3Cl2 can be chain extended with a second monomer to form a well-defined block copolymer in a process known as Photoinduced Electron Transfer RAFT (PET-RAFT). When PET-RAFT is used to chain extend POEGMA with benzyl methacrylate (BzMA) in ethanol (EtOH), polymeric nanoparticles with different morphologies are formed in situ according to a polymerization-induced self-assembly (PISA) mechanism. Self-assembly into nanoparticles presenting POEGMA chains at the corona and poly(benzyl methacrylate) (PBzMA) chains in the core occurs in situ due to the growing insolubility of the PBzMA block in ethanol. Interestingly, the formation of highly pure worm-like micelles can be readily monitored by observing the onset of a highly viscous gel in situ due to nanoparticle entanglements occurring during the polymerization. This process thereby allows for a more reproducible synthesis of worm-like micelles simply by monitoring the solution viscosity during the course of the polymerization. In addition, the light stimulus can be intermittently applied in an ON/OFF manner demonstrating temporal control over the nanoparticle morphology.

  2. The effectiveness of a cognitive task analysis informed curriculum to increase self-efficacy and improve performance for an open cricothyrotomy.

    PubMed

    Campbell, Julia; Tirapelle, Leslie; Yates, Kenneth; Clark, Richard; Inaba, Kenji; Green, Donald; Plurad, David; Lam, Lydia; Tang, Andrew; Cestero, Ramon; Sullivan, Maura

    2011-01-01

    This study explored the effects of a cognitive task analysis (CTA)-informed curriculum to increase surgical skills performance and self-efficacy beliefs for medical students and postgraduate surgical residents learning how to perform an open cricothyrotomy. Third-year medical students and postgraduate year 2 and 3 surgery residents were assigned randomly to either the CTA group (n = 12) or the control group (n = 14). The CTA group learned the open cricothyrotomy procedure using the CTA curriculum. The control group received the traditional curriculum. The CTA group outperformed the control group significantly based on a 19-point checklist score (CTA mean score: 17.75, standard deviation [SD] = 2.34; control mean score: 15.14, SD = 2.48; p = 0.006). The CTA group also reported significantly higher self-efficacy scores based on a 140-point self-appraisal inventory (CTA mean score: 126.10, SD = 16.90; control: 110.67, SD = 16.8; p = 0.029). The CTA curriculum was effective in increasing the performance and self-efficacy scores for postgraduate surgical residents and medical students performing an open cricothyrotomy. Copyright © 2011 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. Decoding Hemodynamics of Large Vessels via Dispersion of Contrast Agent in Cardiac Computed Tomography

    NASA Astrophysics Data System (ADS)

    Eslami, Parastou; Seo, Jung-Hee; Abd, Thura T.; George, Richard; Lardo, Albert C.; Chen, Marcus Y.; Mittal, Rajat

    2015-11-01

    Computed tomography angiography (CTA) has emerged as a powerful tool for the assessment of coronary artery disease and other cardiac conditions. Continuous improvements in the spatial and temporal resolution of CT scanners are revealing details regarding the spatially and temporally varying contrast concentration in the vasculature, that were not evident before. These contrast dispersion patterns offer the possibility of extracting useful information about the hemodynamics from the scans. In the current presentation, we will describe experimental studies carried out with CT compatible phantoms of coronary vessels that provide insights into the effect of imaging artifacts on the observed intracoronary contrast gradients. In addition, we will describe a series of computational fluid dynamics studies that explore the dispersion of contrast through the ascending-descending aorta with particular focus on the effect of the aortic curvature on the dispersion patterns. PE is supported by the NIH Graduate Partnership Program. RM and ACL pending patents in CTA based flow diagnostics and have other significant financial interests in these technologies.

  4. CTA1: Purified and display onto gram-positive enhancer matrix (GEM) particles as mucosal adjuvant.

    PubMed

    Zhang, Yuanpeng; Yu, Xiaoming; Hou, Liting; Chen, Jin; Li, Pengcheng; Qiao, Xuwen; Zheng, Qisheng; Hou, Jibo

    2018-01-01

    The A1 subunit of cholera toxin (CTA1) retains the adjuvant function of CT, without its toxic side effects, making the molecule a promising mucosal adjuvant. However, the methods required to obtain a pure product are both complicated and expensive, constricting its potential commercial applicability. Here, we fused the peptidoglycan binding domain (PA) to the C-terminus of CTA1, which enabled the fusion protein to be expressed by Bacillus subtilis, and secreted into the culture medium. CTA1 was then purified and displayed on GEM particles using a one step process, which resulted in the formation of CTA1-GEM complexes. Next, the CTA1-GEM complexes were used as an adjuvant to enhance the immune responses of mice to the influenza subunit vaccine. It was observed that the CTA1-GEM complexes enhanced specific systemic (IgG) and mucosal (IgA) immune responses against antigen, and induced cellular immune responses as well. The data presented here suggests that CTA1-GEM complexes can serve as a viable mucosal adjuvant. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Single Phase Dual-energy CT Angiography: One-stop-shop Tool for Evaluating Aneurysmal Subarachnoid Hemorrhage.

    PubMed

    Ni, Qian Qian; Tang, Chun Xiang; Zhao, Yan E; Zhou, Chang Sheng; Chen, Guo Zhong; Lu, Guang Ming; Zhang, Long Jiang

    2016-05-25

    Aneurysmal subarachnoid hemorrhages have extremely high case fatality in clinic. Early and rapid identifications of ruptured intracranial aneurysms seem to be especially important. Here we evaluate clinical value of single phase contrast-enhanced dual-energy CT angiograph (DE-CTA) as a one-stop-shop tool in detecting aneurysmal subarachnoid hemorrhage. One hundred and five patients who underwent true non-enhanced CT (TNCT), contrast-enhanced DE-CTA and digital subtraction angiography (DSA) were included. Image quality and detectability of intracranial hemorrhage were evaluated and compared between virtual non-enhanced CT (VNCT) images reconstructed from DE-CTA and TNCT. There was no statistical difference in image quality (P > 0.05) between VNCT and TNCT. The agreement of VNCT and TNCT in detecting intracranial hemorrhage reached 98.1% on a per-patient basis. With DSA as reference standard, sensitivity and specificity on a per-patient were 98.3% and 97.9% for DE-CTA in intracranial aneurysm detection. Effective dose of DE-CTA was reduced by 75.0% compared to conventional digital subtraction CTA. Thus, single phase contrast-enhanced DE-CTA is optimal reliable one-stop-shop tool for detecting intracranial hemorrhage with VNCT and intracranial aneurysms with DE-CTA with substantial radiation dose reduction compared with conventional digital subtraction CTA.

  6. Single Phase Dual-energy CT Angiography: One-stop-shop Tool for Evaluating Aneurysmal Subarachnoid Hemorrhage

    PubMed Central

    Ni, Qian Qian; Tang, Chun Xiang; Zhao, Yan E; Zhou, Chang Sheng; Chen, Guo Zhong; Lu, Guang Ming; Zhang, Long Jiang

    2016-01-01

    Aneurysmal subarachnoid hemorrhages have extremely high case fatality in clinic. Early and rapid identifications of ruptured intracranial aneurysms seem to be especially important. Here we evaluate clinical value of single phase contrast-enhanced dual-energy CT angiograph (DE-CTA) as a one-stop-shop tool in detecting aneurysmal subarachnoid hemorrhage. One hundred and five patients who underwent true non-enhanced CT (TNCT), contrast-enhanced DE-CTA and digital subtraction angiography (DSA) were included. Image quality and detectability of intracranial hemorrhage were evaluated and compared between virtual non-enhanced CT (VNCT) images reconstructed from DE-CTA and TNCT. There was no statistical difference in image quality (P > 0.05) between VNCT and TNCT. The agreement of VNCT and TNCT in detecting intracranial hemorrhage reached 98.1% on a per-patient basis. With DSA as reference standard, sensitivity and specificity on a per-patient were 98.3% and 97.9% for DE-CTA in intracranial aneurysm detection. Effective dose of DE-CTA was reduced by 75.0% compared to conventional digital subtraction CTA. Thus, single phase contrast-enhanced DE-CTA is optimal reliable one-stop-shop tool for detecting intracranial hemorrhage with VNCT and intracranial aneurysms with DE-CTA with substantial radiation dose reduction compared with conventional digital subtraction CTA. PMID:27222163

  7. Area postrema ablations in cats: Evidence for separate neural routes for motion- and xylazine-induced CTA and emesis

    NASA Technical Reports Server (NTRS)

    Corcoran, Meryl Lee; Fox, Robert A.; Brizzee, Kenneth R.; Crampton, G.; Daunton, Nancy G.

    1991-01-01

    Previous studies on the role of the area postrema (AP) in vomiting induced in the cat by motion and drugs have shown that the AP is not essential for motion-induced vomiting, but is necessary for vomiting to apomorphine and xylazine. To confirm these findings and to determine the role of the AP in the formation of Conditioned Taste Aversion (CTA), the AP was ablated bilaterally in 10 adult female cats. With one exception, the ablated cats continued to vomit to the same motion that elicited emesis before the ablation. Doses of xylazine and apomorphine that elicit emesis in intact cats, failed to induce emesis in the ablated cats. Histological examination indicated that 8 cats had complete lesions and 2 had partial lesions. Investigations of effects of AP ablations on CTA revealed that cats with complete lesions did not form CTA to flavored milk paired with xylazine-induced CTA. Seven of the eigth completely lesioned cats developed motion-induced CTA, even though emesis was not consistently elicited by motion. These results suggest that there are multiple routes for inducing CTA and the emetic reflex, that CTA can form without eliciting emesis, and that CTA may be a sensitive measure of sub-emetic motion sickness.

  8. Role of acetaldehyde in ethanol-induced conditioned taste aversion in rats.

    PubMed

    Escarabajal, M Dolores; De Witte, Philippe; Quertemont, Etienne

    2003-05-01

    In spite of many recent studies on the effects of acetaldehyde, it is still unclear whether acetaldehyde mediates the reinforcing and/or aversive effects of ethanol. The present study reexamined the role of acetaldehyde in ethanol-induced conditioned taste aversion (CTA). A first experiment compared ethanol- and acetaldehyde-induced CTA. In a second experiment, cyanamide, an aldehyde dehydrogenase inhibitor, was administered before conditioning with either ethanol or acetaldehyde to investigate the effects of acetaldehyde accumulation. A classic CTA protocol was used to associate the taste of a saccharin solution with either ethanol or acetaldehyde injections. In experiment 1, saccharin consumption was followed by injections of either ethanol (0, 0.5, 1.0, 1.5 or 2.0 g/kg) or acetaldehyde (0, 100, 170 or 300 mg/kg). In experiment 2, the rats were pretreated with either saline or cyanamide (25 mg/kg) before conditioning with either ethanol or acetaldehyde. Both ethanol and acetaldehyde induced significant CTA. However, ethanol produced a very strong CTA relative to acetaldehyde that induced only a weak CTA even at toxic doses. Cyanamide pretreatments significantly potentiated ethanol- but not acetaldehyde-induced CTA. The present results indicate that ethanol-induced CTA does not result from brain acetaldehyde effects. In contrast, it is suggested that the reinforcing effects of brain acetaldehyde might actually reduce ethanol-induced CTA. Our results also suggest that the inhibition of brain catalase activity may contribute to the potentiating effects of cyanamide on ethanol-induced CTA.

  9. Diagnostic accuracy of CTA and MRI/MRA in the evaluation of the cortical venous reflux in the intracranial dural arteriovenous fistula DAVF.

    PubMed

    Lin, Yen-Heng; Wang, Yu-Fen; Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang; Hsieh, Hong-Jen

    2018-01-01

    Computed tomography angiography (CTA) and magnetic resonance imaging/angiography (MRI/MRA) are used for the diagnosis of intracranial dural arteriovenous fistulas (DAVFs). The purpose of this study was to compare the diagnostic accuracy of CTA and magnetic resonance imaging/angiography (MRI/MRA) for detection of cortical venous reflux (CVR) in intracranial DAVFs. The records of patients with angiography-confirmed intracranial DAVFs who also received CTA and MRI/MRA from January 2008 to July 2016 were reviewed. CTA and MRI/MRA were reviewed for signs of CVR, and the diagnostic accuracy of individual signs was evaluated by receiver operating curve (ROC) analysis. A total 108 patients were included in this study. CTA signs of CVR included abnormal dilatation, early enhancement, and the presence of a medullary or pial vein. MRI/MRA signs of CVR included abnormal dilatation, early enhancement, flow-related enhancement, flow void, and medullary or pial venous collaterals. The sensitivity of individual CTA signs ranged from 62 to 96%, and specificities from 79 to 94%. The sensitivities of individual MRI/MRA signs ranged from 58 to 83%, and specificities from 77 to 93%. The area under ROC curve (AUC) of CTA and MRI/MRA were 0.91 and 0.87, respectively (P = 0.04 in direct comparison). In subgroup analysis, CTA had better diagnostic accuracy for higher grade disease (P = 0.05) and non-aggressive manifestation (P = 0.04). Both CTA and MRI/MRA have good diagnostic accuracy for detection of CVR in patients with intracranial DAVFs. There is modest evidence that CTA is better than MRI/MRA.

  10. Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16‐slice and 64‐slice scanner data with conventional coronary angiography

    PubMed Central

    Deetjen, Anja; Möllmann, Susanne; Conradi, Guido; Rolf, Andreas; Schmermund, Axel; Hamm, Christian W; Dill, Thorsten

    2007-01-01

    Objective To evaluate the radiation‐dose‐reduction potential of automatic exposure control (AEC) in 16‐slice and 64‐slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure. Design A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16‐slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64‐slice scanner (with AEC, without ECG‐triggered tube current modulation). Results In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8‐fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV. Conclusions This is the first study to show the significant dose‐reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA. PMID:17395667

  11. Activation of the hypothalamic-pituitary-adrenal axis in lithium-induced conditioned taste aversion learning.

    PubMed

    Jahng, Jeong Won; Lee, Jong-Ho

    2015-12-05

    Intraperitoneal injections (ip) of lithium chloride at large doses induce c-Fos expression in the brain regions implicated in conditioned taste aversion (CTA) learning, and also activate the hypothalamic-pituitary-adrenal (HPA) axis and increase the plasma corticosterone levels in rats. A pharmacologic treatment blunting the lithium-induced c-Fos expression in the brain regions, but not the HPA axis activation, induced CTA formation. Synthetic glucocorticoids at conditioning, but not glucocorticoid antagonist, attenuated the lithium-induced CTA acquisition. The CTA acquisition by ip lithium was not affected by adrenalectomy regardless of basal corticosterone supplement, but the extinction was delayed in the absence of basal corticosterone. Glucocorticoids overloading delayed the extinction memory formation of lithium-induced CTA. ip lithium consistently induced the brain c-Fos expression, the HPA activation and CTA formation regardless of the circadian activation of the HPA axis. Intracerebroventricular (icv) injections of lithium at day time also increased the brain c-Fos expression, activated the HPA axis and induced CTA acquisition. However, icv lithium at night, when the HPA axis shows its circadian activation, did not induce CTA acquisition nor activate the HPA axis, although it increased the brain c-Fos expression. These results suggest that the circadian activation of the HPA axis may affect central, but not peripheral, effect of lithium in CTA learning in rats, and the HPA axis activation may be necessary for the central effect of lithium in CTA formation. Also, glucocorticoids may be required for a better extinction; however, increased glucocorticoids hinder both the acquisition and the extinction of lithium-induced CTA. Copyright © 2015. Published by Elsevier B.V.

  12. The detection of the capsular tear at the undersurface of the extensor carpi radialis brevis tendon in chronic tennis elbow: the value of magnetic resonance imaging and computed tomography arthrography.

    PubMed

    Sasaki, Koichi; Tamakawa, Mitsuharu; Onda, Kazunori; Iba, Kosuke; Sonoda, Tomoko; Yamashita, Toshihiko; Wada, Takuro

    2011-04-01

    This study compared the diagnostic efficacy of magnetic resonance imaging (MRI) and computed tomography arthrography (CTA) in the assessment of capsular tears at the undersurface of the extensor carpi radials brevis tendon in chronic tennis elbow using arthroscopy as a gold standard. Because of the higher spatial resolution of CT, we hypothesized that CTA is superior to MRI for assessing capsular tears. We retrospectively reviewed 19 consecutive patients with chronic tennis elbow with preoperative MRI and CTA studies who underwent arthroscopic surgery. Three observers with different levels of training and experience (musculoskeletal radiologist, experienced elbow surgeon, and hand fellow) evaluated the capsular tear by MRI and CTA in a blinded manner. The results of the MRI and CTA were compared and the agreement among the 3 observers was determined using an intraclass correlation coefficient (ICC). Then, the results of the MRI and CTA examinations were compared with the intraoperative findings of the arthroscopic examination. The sensitivity, specificity, and κ value were calculated. The ICC of CTA (0.855) was superior to MRI (0.645). The sensitivity, specificity, and κ value of CTA were superior to those of MRI in each of the 3 observers. The κ value was 0.79, 0.89, and 0.79 for CTA, and 0.48, 0.48, and 0.27 for MRI for the radiologist, surgeon, and fellow, respectively. CTA was a reliable and accurate diagnostic modality compared with MRI to detect the capsular tear in patients with chronic tennis elbow. CTA was less influenced by the observer's experience. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Safety of coronary CT angiography and functional testing for stable chest pain in the PROMISE trial: A randomized comparison of test complications, incidental findings, and radiation dose.

    PubMed

    Lu, Michael T; Douglas, Pamela S; Udelson, James E; Adami, Elizabeth; Ghoshhajra, Brian B; Picard, Michael H; Roberts, Rhonda; Lee, Kerry L; Einstein, Andrew J; Mark, Daniel B; Velazquez, Eric J; Carter, William; Ridner, Michael; Al-Khalidi, Hussein R; Hoffmann, Udo

    Coronary computed tomography angiography (CTA) and functional testing strategies for stable chest pain yield similar outcomes; one aspect that may guide test choice is safety. We compared test safety (test complications, incidental findings, and effective radiation dose) between CTA and functional testing as-tested in PROMISE (PROspective Multicenter Imaging Study for Evaluation of Chest Pain). In the subgroup whose physicians intended nuclear stress over other functional tests if randomized to the functional arm, we compared radiation dose of CTA versus nuclear stress and identified characteristics associated with dose. Of 9470 patients, none had major and <1% had minor complications (CTA: 0.8% [37/4633] vs. functional: 0.6% [27/4837]). CTA identified more incidental findings (11.6% [539/4633] vs. 0.7% [34/4837], p < 0.001), most commonly pulmonary nodules (9.4%, 437/4633). CTA had similar 90-day cumulative radiation dose to functional testing. However, in the subgroup whose physicians intended nuclear stress (CTA 3147; nuclear 3203), CTA had lower median index test (8.8 vs. 12.6 mSv, p < 0.001) and 90-day cumulative (11.6 vs. 13.1 mSv, p < 0.001) dose, independent of patient characteristics. The lowest nuclear doses employed 1-day Tc-99m protocols (12.2 mSv). The lowest CTA doses were at sites performing ≥500 CTAs/year (6.9 mSv) and with advanced (latest available) CT scanners (5.5 mSv). Complications were negligibly rare for both CTA and functional testing. CTA detects more incidental findings. Compared to nuclear stress testing, CTA's lower radiation dose, independent of patient characteristics, makes it an attractive test choice. Radiation dose varies with imaging protocol, indicating opportunities to further reduce dose. (ClinicalTrials.gov number, NCT01174550). Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. The Cherenkov Telescope Array For Very High-Energy Astrophysics

    NASA Astrophysics Data System (ADS)

    Kaaret, Philip

    2015-08-01

    The field of very high energy (VHE) astrophysics had been revolutionized by the results from ground-based gamma-ray telescopes, including the current imaging atmospheric Cherenkov telescope (IACT) arrays: HESS, MAGIC and VERITAS. A worldwide consortium of scientists from 29 countries has formed to propose the Cherenkov Telescope Array (CTA) that will capitalize on the power of this technique to greatly expand the scientific reach of ground-based gamma-ray telescopes. CTA science will include key topics such as the origin of cosmic rays and cosmic particle acceleration, understanding extreme environments in regions close to neutron stars and black holes, and exploring physics frontiers through, e.g., the search for WIMP dark matter, axion-like particles and Lorentz invariance violation. CTA is envisioned to consist of two large arrays of Cherenkov telescopes, one in the southern hemisphere and one in the north. Each array will contain telescopes of different sizes to provide a balance between cost and array performance over an energy range from below 100 GeV to above 100 TeV. Compared to the existing IACT arrays, CTA will have substantially better angular resolution and energy resolution, will cover a much wider energy range, and will have up to an order of magnitude better sensitivity. CTA will also be operated as an open observatory and high-level CTA data will be placed into the public domain; these aspects will enable broad participation in CTA science from the worldwide scientific community to fully capitalize on CTA's potential. This talk will: 1) review the scientific motivation and capabilities of CTA, 2) provide an overview of the technical design and the status of prototype development, and 3) summarize the current status of the project in terms of its proposed organization and timeline. The plans for access to CTA data and opportunities to propose for CTA observing time will be highlighed.Presented on behalf of the CTA Consortium.

  15. Effects of abutment screw coating on implant preload.

    PubMed

    Park, Jae-Kyoung; Choi, Jin-Uk; Jeon, Young-Chan; Choi, Kyung-Soo; Jeong, Chang-Mo

    2010-08-01

    The aim of the present study was to investigate the effects of tungsten carbide carbon (WC/CTa) screw surface coating on abutment screw preload in three implant connection systems in comparison to noncoated titanium alloy (Ta) screws. Preload of WC/CTa abutment screws was compared to noncoated Ta screws in three implant connection systems. The differences in preloads were measured in tightening rotational angle, compression force, initial screw removal torque, and postload screw removal torque after 1 million cyclic loads. Preload loss percent was calculated to determine the efficacy of maintaining the preload of two abutment screw types in relation to implant connection systems. WC/CTa screws provided 10 degrees higher tightening rotational angle than Ta screws in all three connection systems. This difference was statistically significant (p < 0.05). External-hex butt joint implant connections had a higher compression force than the two internal conical implant connections. WC/CTa screws provided a statistically significantly higher compression force than Ta screws in all three implant connections (p < 0.05). Ta screws required statistically higher removal torque than WC/CTa screws in all three implant connections (p < 0.05); however, Ta screws needed statistically lower postload removal torque than WC/CTa screws in all three implant connections (p < 0.05). Ta screws had a statistically higher preload loss percent than WC/CTa screws in all three implant connections (p < 0.05), indicating that WC/CTa screws were superior in maintaining the preload than Ta screws. Within the limits of present study, the following conclusions were made: (1) WC/CTa screws provided higher preload than noncoated Ta screws in all three implant connection systems. (2) The initial removal torque for Ta screws required higher force than WC/CTa screws, whereas postload removal torque for Ta screws was lower than WC/CTa screws. Calculated Ta screw preload loss percent was higher than for WC/CTa screws, suggesting that WC/CTa screws were more effective in maintaining the preload than Ta screws. (3) Internal conical connections were more effective in maintaining the screw preload in cyclic loads than external-hex butt joint connections.

  16. Digital Subtraction Angiography or Computed Tomography Angiography in the Preoperative Evaluation of Lower Limb Peripheral Artery Disease - A Comparative Analysis.

    PubMed

    Dias-Neto, Marina; Marques, Catarina; Sampaio, Sérgio

    2017-01-01

    For several years, digital subtraction angiography (DSA) was considered the gold standard method for the evaluation of PAD patients. This is an invasive technique and allows a good evaluation of collaterals and the vessel lumen, even in cases with associated calcification. Nevertheless, recent technical development of computed tomography angiography (CTA) has improved its specificity and sensibility, besides the fact that CTA is a fast and non-invasive procedure. To characterize a cohort of lower limb PAD patients and clarify if there are differences among the patients preoperatively evaluated by DSA or CTA. This retrospective study focused on PAD patients with a Rutherford classification ≥ 3 and submitted to intervention (endovascular revascularization or open surgery). The CTA group included all patients submitted to this method as their preoperative exam, between March 2009 and April 2017. In the same period of time, patients submitted to DSA as their preoperative exam, were randomly selected. The exclusion criteria were: realization of the exam for a different diagnosis than PAD, amputation not preceded by revascularization, absence of intervention during a period of 1 year after the realization of the exam. The groups were compared upon the type of surgery (open vs endovascular), number of revascularization sectors, reintervention, amputation, mortality and length of hospital stay. 34 CTA patients and 71 DSA patients were included. The groups were demographically and clinically homogeneous. In what regards to arterial lesions, the DSA group showed more often lesions of the distal sector with TASC C or D classification (25% in DSA group and 0% in CTA group; p=0,001), as well as scarcity of runoff vessels (0 or 1 in 72% of DSA patients group and 26% in CTA group; p=0.001). There were no differences about the endovascular and open surgery ratio (1.8 to CTA and 1.4 to DSA; p=0.305), reintervention rates (21% CTA and 16% DSA; p=0.517), major amputation (9% CTA and 11% DSA; p=1), minor amputation (9% CTA and 16% DSA; p=0.541), mortality (18% CTA and 23% DSA; p=0,602), or length of hospital stay (median and (interquartile range) of 14 (27) for CTA and 14 (17) for DSA; p=0.933). CTA seems to be a method for morphological and therapeutic planning of PAD that is non-inferior to DSA.

  17. Excitation of lateral habenula neurons as a neural mechanism underlying ethanol-induced conditioned taste aversion.

    PubMed

    Tandon, Shashank; Keefe, Kristen A; Taha, Sharif A

    2017-02-15

    The lateral habenula (LHb) has been implicated in regulation of drug-seeking behaviours through aversion-mediated learning. In this study, we recorded neuronal activity in the LHb of rats during an operant task before and after ethanol-induced conditioned taste aversion (CTA) to saccharin. Ethanol-induced CTA caused significantly higher baseline firing rates in LHb neurons, as well as elevated firing rates in response to cue presentation, lever press and saccharin taste. In a separate cohort of rats, we found that bilateral LHb lesions blocked ethanol-induced CTA. Our results strongly suggest that excitation of LHb neurons is required for ethanol-induced CTA, and point towards a mechanism through which LHb firing may regulate voluntary ethanol consumption. Ethanol, like other drugs of abuse, has both rewarding and aversive properties. Previous work suggests that sensitivity to ethanol's aversive effects negatively modulates voluntary alcohol intake and thus may be important in vulnerability to developing alcohol use disorders. We previously found that rats with lesions of the lateral habenula (LHb), which is implicated in aversion-mediated learning, show accelerated escalation of voluntary ethanol consumption. To understand neural encoding in the LHb contributing to ethanol-induced aversion, we recorded neural firing in the LHb of freely behaving, water-deprived rats before and after an ethanol-induced (1.5 g kg -1 20% ethanol, i.p.) conditioned taste aversion (CTA) to saccharin taste. Ethanol-induced CTA strongly decreased motivation for saccharin in an operant task to obtain the tastant. Comparison of LHb neural firing before and after CTA induction revealed four main differences in firing properties. First, baseline firing after CTA induction was significantly higher. Second, firing evoked by cues signalling saccharin availability shifted from a pattern of primarily inhibition before CTA to primarily excitation after CTA induction. Third, CTA induction reduced the magnitude of lever press-evoked inhibition. Finally, firing rates were significantly higher during consumption of the devalued saccharin solution after CTA induction. Next, we studied sham- and LHb-lesioned rats in our operant CTA paradigm and found that LHb lesion significantly attenuated CTA effects in the operant task. Our data demonstrate the importance of LHb excitation in regulating expression of ethanol-induced aversion and suggest a mechanism for its role in modulating escalation of voluntary ethanol intake. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  18. Excitation of lateral habenula neurons as a neural mechanism underlying ethanol‐induced conditioned taste aversion

    PubMed Central

    Keefe, Kristen A.; Taha, Sharif A.

    2016-01-01

    Key points The lateral habenula (LHb) has been implicated in regulation of drug‐seeking behaviours through aversion‐mediated learning.In this study, we recorded neuronal activity in the LHb of rats during an operant task before and after ethanol‐induced conditioned taste aversion (CTA) to saccharin.Ethanol‐induced CTA caused significantly higher baseline firing rates in LHb neurons, as well as elevated firing rates in response to cue presentation, lever press and saccharin taste.In a separate cohort of rats, we found that bilateral LHb lesions blocked ethanol‐induced CTA.Our results strongly suggest that excitation of LHb neurons is required for ethanol‐induced CTA, and point towards a mechanism through which LHb firing may regulate voluntary ethanol consumption. Abstract Ethanol, like other drugs of abuse, has both rewarding and aversive properties. Previous work suggests that sensitivity to ethanol's aversive effects negatively modulates voluntary alcohol intake and thus may be important in vulnerability to developing alcohol use disorders. We previously found that rats with lesions of the lateral habenula (LHb), which is implicated in aversion‐mediated learning, show accelerated escalation of voluntary ethanol consumption. To understand neural encoding in the LHb contributing to ethanol‐induced aversion, we recorded neural firing in the LHb of freely behaving, water‐deprived rats before and after an ethanol‐induced (1.5 g kg−1 20% ethanol, i.p.) conditioned taste aversion (CTA) to saccharin taste. Ethanol‐induced CTA strongly decreased motivation for saccharin in an operant task to obtain the tastant. Comparison of LHb neural firing before and after CTA induction revealed four main differences in firing properties. First, baseline firing after CTA induction was significantly higher. Second, firing evoked by cues signalling saccharin availability shifted from a pattern of primarily inhibition before CTA to primarily excitation after CTA induction. Third, CTA induction reduced the magnitude of lever press‐evoked inhibition. Finally, firing rates were significantly higher during consumption of the devalued saccharin solution after CTA induction. Next, we studied sham‐ and LHb‐lesioned rats in our operant CTA paradigm and found that LHb lesion significantly attenuated CTA effects in the operant task. Our data demonstrate the importance of LHb excitation in regulating expression of ethanol‐induced aversion and suggest a mechanism for its role in modulating escalation of voluntary ethanol intake. PMID:27682823

  19. Transfiguring structural, optical and dielectric properties of cadmium thiourea acetate crystal by the addition of L-threonine for laser assisted device applications

    NASA Astrophysics Data System (ADS)

    Kulkarni, Rupali B.; Anis, Mohd; Hussaini, S. S.; Shirsat, Mahendra D.

    2018-03-01

    Present investigation reports the growth of pure and L-threonine (LT) doped cadmium thiourea acetate (CTA) crystals by slow solution evaporation technique followed by structural, optical and dielectric characterization studies. A bulk single crystal of LT-CTA has been grown at temperature 38 °C. The single crystal x-ray diffraction technique has been employed to confirm the structural parameters of pure and LT doped CTA crystals. The increase in optical transparency of LT-CTA crystal was ascertained in the range of 200 to 900 nm using UV-visible spectral analysis. The widened optical band gap of the LT-CTA crystal is found to be 4.7 eV. Pure and doped crystals are subjected to FT-IR analysis to indicate the presence of functional groups quantitatively. Appreciable enhancement in second harmonic generation (SHG) efficiency of LT-CTA crystal with reference to parent CTA was confirmed from Kurtz-Perry SHG test (1.31 times of CTA crystal). The assertive influence of LT on electrical properties of grown crystals has been investigated in the temperature range 35 °C-120 °C. Electronic purity and the color centered photoluminescence emission nature of pure and IA-CTA crystals were justified by luminescence analysis. With the aid of single beam Z-scan analysis, the Kerr lensing nonlinearity was identified and the magnitude of TONLO parameters has been determined. The cubic susceptibility (χ3) and figure of merit (FOM) was found to be 4.81 × 10-4esu and 978.35. Results vitalize LT-CTA for laser stabilization systems.

  20. Four-dimensional computed tomography angiographic evaluation of cranial dural arteriovenous fistula before and after embolization.

    PubMed

    Tian, Bing; Xu, Bing; Lu, Jianping; Liu, Qi; Wang, Li; Wang, Minjie

    2015-06-01

    This study aimed to evaluate the usefulness of four-dimensional CTA before and after embolization treatment with ONYX-18 in eleven patients with cranial dural arteriovenous fistulas, and to compare the results with those of the reference standard DSA. Eleven patients with cranial dural arteriovenous fistulas detected on DSA underwent transarterial embolization with ONYX-18. Four-dimensional CTA was performed an average of 2 days before and 4 days after DSA. Four-dimensional CTA and DSA images were reviewed by two neuroradiologists for identification of feeding arteries and drainage veins and for determining treatment effects. Interobserver and intermodality agreement between four-dimensional CTA and DSA were assessed. Forty-two feeding arteries were identified for 14 fistulas in the 11 patients. Of these, 36 (85.71%) were detected on four-dimensional CTA. After transarterial embolization, one patient got partly embolized, and the fistulas in the remaining 10 patients were completely occluded. The interobserver agreement for four-dimensional CTA and intermodality agreement between four-dimensional CTA and DSA were excellent (κ=1) for shunt location, identification of drainage veins, and fistula occlusion after treatment. Four-dimensional CTA images are highly accurate when compared with DSA images both before and after transarterial embolization treatment. Four-dimensional CTA can be used for diagnosis as well as follow-up of cranial dural arteriovenous fistulas in clinical settings. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Introducing the CTA concept

    NASA Astrophysics Data System (ADS)

    Acharya, B. S.; Actis, M.; Aghajani, T.; Agnetta, G.; Aguilar, J.; Aharonian, F.; Ajello, M.; Akhperjanian, A.; Alcubierre, M.; Aleksić, J.; Alfaro, R.; Aliu, E.; Allafort, A. J.; Allan, D.; Allekotte, I.; Amato, E.; Anderson, J.; Angüner, E. O.; Antonelli, L. A.; Antoranz, P.; Aravantinos, A.; Arlen, T.; Armstrong, T.; Arnaldi, H.; Arrabito, L.; Asano, K.; Ashton, T.; Asorey, H. G.; Awane, Y.; Baba, H.; Babic, A.; Baby, N.; Bähr, J.; Bais, A.; Baixeras, C.; Bajtlik, S.; Balbo, M.; Balis, D.; Balkowski, C.; Bamba, A.; Bandiera, R.; Barber, A.; Barbier, C.; Barceló, M.; Barnacka, A.; Barnstedt, J.; Barres de Almeida, U.; Barrio, J. A.; Basili, A.; Basso, S.; Bastieri, D.; Bauer, C.; Baushev, A.; Becerra, J.; Becherini, Y.; Bechtol, K. C.; Becker Tjus, J.; Beckmann, V.; Bednarek, W.; Behera, B.; Belluso, M.; Benbow, W.; Berdugo, J.; Berger, K.; Bernard, F.; Bernardino, T.; Bernlöhr, K.; Bhat, N.; Bhattacharyya, S.; Bigongiari, C.; Biland, A.; Billotta, S.; Bird, T.; Birsin, E.; Bissaldi, E.; Biteau, J.; Bitossi, M.; Blake, S.; Blanch Bigas, O.; Blasi, P.; Bobkov, A.; Boccone, V.; Boettcher, M.; Bogacz, L.; Bogart, J.; Bogdan, M.; Boisson, C.; Boix Gargallo, J.; Bolmont, J.; Bonanno, G.; Bonardi, A.; Bonev, T.; Bonifacio, P.; Bonnoli, G.; Bordas, P.; Borgland, A.; Borkowski, J.; Bose, R.; Botner, O.; Bottani, A.; Bouchet, L.; Bourgeat, M.; Boutonnet, C.; Bouvier, A.; Brau-Nogué, S.; Braun, I.; Bretz, T.; Briggs, M.; Bringmann, T.; Brook, P.; Brun, P.; Brunetti, L.; Buanes, T.; Buckley, J.; Buehler, R.; Bugaev, V.; Bulgarelli, A.; Bulik, T.; Busetto, G.; Buson, S.; Byrum, K.; Cailles, M.; Cameron, R.; Camprecios, J.; Canestrari, R.; Cantu, S.; Capalbi, M.; Caraveo, P.; Carmona, E.; Carosi, A.; Carr, J.; Carton, P.-H.; Casanova, S.; Casiraghi, M.; Catalano, O.; Cavazzani, S.; Cazaux, S.; Cerruti, M.; Chabanne, E.; Chadwick, P.; Champion, C.; Chen, A.; Chiang, J.; Chiappetti, L.; Chikawa, M.; Chitnis, V. R.; Chollet, F.; Chudoba, J.; Cieślar, M.; Cillis, A.; Cohen-Tanugi, J.; Colafrancesco, S.; Colin, P.; Colome, J.; Colonges, S.; Compin, M.; Conconi, P.; Conforti, V.; Connaughton, V.; Conrad, J.; Contreras, J. L.; Coppi, P.; Corona, P.; Corti, D.; Cortina, J.; Cossio, L.; Costantini, H.; Cotter, G.; Courty, B.; Couturier, S.; Covino, S.; Crimi, G.; Criswell, S. J.; Croston, J.; Cusumano, G.; Dafonseca, M.; Dale, O.; Daniel, M.; Darling, J.; Davids, I.; Dazzi, F.; De Angelis, A.; De Caprio, V.; De Frondat, F.; de Gouveia Dal Pino, E. M.; de la Calle, I.; De La Vega, G. A.; de los Reyes Lopez, R.; De Lotto, B.; De Luca, A.; de Mello Neto, J. R. T.; de Naurois, M.; de Oliveira, Y.; de Oña Wilhelmi, E.; de Souza, V.; Decerprit, G.; Decock, G.; Deil, C.; Delagnes, E.; Deleglise, G.; Delgado, C.; Della Volpe, D.; Demange, P.; Depaola, G.; Dettlaff, A.; Di Paola, A.; Di Pierro, F.; Díaz, C.; Dick, J.; Dickherber, R.; Dickinson, H.; Diez-Blanco, V.; Digel, S.; Dimitrov, D.; Disset, G.; Djannati-Ataï, A.; Doert, M.; Dohmke, M.; Domainko, W.; Dominis Prester, D.; Donat, A.; Dorner, D.; Doro, M.; Dournaux, J.-L.; Drake, G.; Dravins, D.; Drury, L.; Dubois, F.; Dubois, R.; Dubus, G.; Dufour, C.; Dumas, D.; Dumm, J.; Durand, D.; Dyks, J.; Dyrda, M.; Ebr, J.; Edy, E.; Egberts, K.; Eger, P.; Einecke, S.; Eleftheriadis, C.; Elles, S.; Emmanoulopoulos, D.; Engelhaupt, D.; Enomoto, R.; Ernenwein, J.-P.; Errando, M.; Etchegoyen, A.; Evans, P.; Falcone, A.; Fantinel, D.; Farakos, K.; Farnier, C.; Fasola, G.; Favill, B.; Fede, E.; Federici, S.; Fegan, S.; Feinstein, F.; Ferenc, D.; Ferrando, P.; Fesquet, M.; Fiasson, A.; Fillin-Martino, E.; Fink, D.; Finley, C.; Finley, J. P.; Fiorini, M.; Firpo Curcoll, R.; Flores, H.; Florin, D.; Focke, W.; Föhr, C.; Fokitis, E.; Font, L.; Fontaine, G.; Fornasa, M.; Förster, A.; Fortson, L.; Fouque, N.; Franckowiak, A.; Fransson, C.; Fraser, G.; Frei, R.; Albuquerque, I. F. M.; Fresnillo, L.; Fruck, C.; Fujita, Y.; Fukazawa, Y.; Fukui, Y.; Funk, S.; Gäbele, W.; Gabici, S.; Gabriele, R.; Gadola, A.; Galante, N.; Gall, D.; Gallant, Y.; Gámez-García, J.; García, B.; Garcia López, R.; Gardiol, D.; Garrido, D.; Garrido, L.; Gascon, D.; Gaug, M.; Gaweda, J.; Gebremedhin, L.; Geffroy, N.; Gerard, L.; Ghedina, A.; Ghigo, M.; Giannakaki, E.; Gianotti, F.; Giarrusso, S.; Giavitto, G.; Giebels, B.; Gika, V.; Giommi, P.; Girard, N.; Giro, E.; Giuliani, A.; Glanzman, T.; Glicenstein, J.-F.; Godinovic, N.; Golev, V.; Gomez Berisso, M.; Gómez-Ortega, J.; Gonzalez, M. M.; González, A.; González, F.; González Muñoz, A.; Gothe, K. S.; Gougerot, M.; Graciani, R.; Grandi, P.; Grañena, F.; Granot, J.; Grasseau, G.; Gredig, R.; Green, A.; Greenshaw, T.; Grégoire, T.; Grimm, O.; Grube, J.; Grudzinska, M.; Gruev, V.; Grünewald, S.; Grygorczuk, J.; Guarino, V.; Gunji, S.; Gyuk, G.; Hadasch, D.; Hagiwara, R.; Hahn, J.; Hakansson, N.; Hallgren, A.; Hamer Heras, N.; Hara, S.; Hardcastle, M. J.; Harris, J.; Hassan, T.; Hatanaka, K.; Haubold, T.; Haupt, A.; Hayakawa, T.; Hayashida, M.; Heller, R.; Henault, F.; Henri, G.; Hermann, G.; Hermel, R.; Herrero, A.; Hidaka, N.; Hinton, J.; Hoffmann, D.; Hofmann, W.; Hofverberg, P.; Holder, J.; Horns, D.; Horville, D.; Houles, J.; Hrabovsky, M.; Hrupec, D.; Huan, H.; Huber, B.; Huet, J.-M.; Hughes, G.; Humensky, T. B.; Huovelin, J.; Ibarra, A.; Illa, J. M.; Impiombato, D.; Incorvaia, S.; Inoue, S.; Inoue, Y.; Ioka, K.; Ismailova, E.; Jablonski, C.; Jacholkowska, A.; Jamrozy, M.; Janiak, M.; Jean, P.; Jeanney, C.; Jimenez, J. J.; Jogler, T.; Johnson, T.; Journet, L.; Juffroy, C.; Jung, I.; Kaaret, P.; Kabuki, S.; Kagaya, M.; Kakuwa, J.; Kalkuhl, C.; Kankanyan, R.; Karastergiou, A.; Kärcher, K.; Karczewski, M.; Karkar, S.; Kasperek, J.; Kastana, D.; Katagiri, H.; Kataoka, J.; Katarzyński, K.; Katz, U.; Kawanaka, N.; Kellner-Leidel, B.; Kelly, H.; Kendziorra, E.; Khélifi, B.; Kieda, D. B.; Kifune, T.; Kihm, T.; Kishimoto, T.; Kitamoto, K.; Kluźniak, W.; Knapic, C.; Knapp, J.; Knödlseder, J.; Köck, F.; Kocot, J.; Kodani, K.; Köhne, J.-H.; Kohri, K.; Kokkotas, K.; Kolitzus, D.; Komin, N.; Kominis, I.; Konno, Y.; Köppel, H.; Korohoda, P.; Kosack, K.; Koss, G.; Kossakowski, R.; Kostka, P.; Koul, R.; Kowal, G.; Koyama, S.; Kozioł, J.; Krähenbühl, T.; Krause, J.; Krawzcynski, H.; Krennrich, F.; Krepps, A.; Kretzschmann, A.; Krobot, R.; Krueger, P.; Kubo, H.; Kudryavtsev, V. A.; Kushida, J.; Kuznetsov, A.; La Barbera, A.; La Palombara, N.; La Parola, V.; La Rosa, G.; Lacombe, K.; Lamanna, G.; Lande, J.; Languignon, D.; Lapington, J.; Laporte, P.; Lavalley, C.; Le Flour, T.; Le Padellec, A.; Lee, S.-H.; Lee, W. H.; Leigui de Oliveira, M. A.; Lelas, D.; Lenain, J.-P.; Leopold, D. J.; Lerch, T.; Lessio, L.; Lieunard, B.; Lindfors, E.; Liolios, A.; Lipniacka, A.; Lockart, H.; Lohse, T.; Lombardi, S.; Lopatin, A.; Lopez, M.; López-Coto, R.; López-Oramas, A.; Lorca, A.; Lorenz, E.; Lubinski, P.; Lucarelli, F.; Lüdecke, H.; Ludwin, J.; Luque-Escamilla, P. L.; Lustermann, W.; Luz, O.; Lyard, E.; Maccarone, M. C.; Maccarone, T. J.; Madejski, G. M.; Madhavan, A.; Mahabir, M.; Maier, G.; Majumdar, P.; Malaguti, G.; Maltezos, S.; Manalaysay, A.; Mancilla, A.; Mandat, D.; Maneva, G.; Mangano, A.; Manigot, P.; Mannheim, K.; Manthos, I.; Maragos, N.; Marcowith, A.; Mariotti, M.; Marisaldi, M.; Markoff, S.; Marszałek, A.; Martens, C.; Martí, J.; Martin, J.-M.; Martin, P.; Martínez, G.; Martínez, F.; Martínez, M.; Masserot, A.; Mastichiadis, A.; Mathieu, A.; Matsumoto, H.; Mattana, F.; Mattiazzo, S.; Maurin, G.; Maxfield, S.; Maya, J.; Mazin, D.; Mc Comb, L.; McCubbin, N.; McHardy, I.; McKay, R.; Medina, C.; Melioli, C.; Melkumyan, D.; Mereghetti, S.; Mertsch, P.; Meucci, M.; Michałowski, J.; Micolon, P.; Mihailidis, A.; Mineo, T.; Minuti, M.; Mirabal, N.; Mirabel, F.; Miranda, J. M.; Mirzoyan, R.; Mizuno, T.; Moal, B.; Moderski, R.; Mognet, I.; Molinari, E.; Molinaro, M.; Montaruli, T.; Monteiro, I.; Moore, P.; Moralejo Olaizola, A.; Mordalska, M.; Morello, C.; Mori, K.; Mottez, F.; Moudden, Y.; Moulin, E.; Mrusek, I.; Mukherjee, R.; Munar-Adrover, P.; Muraishi, H.; Murase, K.; Murphy, A.; Nagataki, S.; Naito, T.; Nakajima, D.; Nakamori, T.; Nakayama, K.; Naumann, C.; Naumann, D.; Naumann-Godo, M.; Nayman, P.; Nedbal, D.; Neise, D.; Nellen, L.; Neustroev, V.; Neyroud, N.; Nicastro, L.; Nicolau-Kukliński, J.; Niedźwiecki, A.; Niemiec, J.; Nieto, D.; Nikolaidis, A.; Nishijima, K.; Nolan, S.; Northrop, R.; Nosek, D.; Nowak, N.; Nozato, A.; O'Brien, P.; Ohira, Y.; Ohishi, M.; Ohm, S.; Ohoka, H.; Okuda, T.; Okumura, A.; Olive, J.-F.; Ong, R. A.; Orito, R.; Orr, M.; Osborne, J.; Ostrowski, M.; Otero, L. A.; Otte, N.; Ovcharov, E.; Oya, I.; Ozieblo, A.; Padilla, L.; Paiano, S.; Paillot, D.; Paizis, A.; Palanque, S.; Palatka, M.; Pallota, J.; Panagiotidis, K.; Panazol, J.-L.; Paneque, D.; Panter, M.; Paoletti, R.; Papayannis, A.; Papyan, G.; Paredes, J. M.; Pareschi, G.; Parks, G.; Parraud, J.-M.; Parsons, D.; Paz Arribas, M.; Pech, M.; Pedaletti, G.; Pelassa, V.; Pelat, D.; Perez, M. d. C.; Persic, M.; Petrucci, P.-O.; Peyaud, B.; Pichel, A.; Pita, S.; Pizzolato, F.; Platos, Ł.; Platzer, R.; Pogosyan, L.; Pohl, M.; Pojmanski, G.; Ponz, J. D.; Potter, W.; Poutanen, J.; Prandini, E.; Prast, J.; Preece, R.; Profeti, F.; Prokoph, H.; Prouza, M.; Proyetti, M.; Puerto-Gimenez, I.; Pühlhofer, G.; Puljak, I.; Punch, M.; Pyzioł, R.; Quel, E. J.; Quinn, J.; Quirrenbach, A.; Racero, E.; Rajda, P. J.; Ramon, P.; Rando, R.; Rannot, R. C.; Rataj, M.; Raue, M.; Reardon, P.; Reimann, O.; Reimer, A.; Reimer, O.; Reitberger, K.; Renaud, M.; Renner, S.; Reville, B.; Rhode, W.; Ribó, M.; Ribordy, M.; Richer, M. G.; Rico, J.; Ridky, J.; Rieger, F.; Ringegni, P.; Ripken, J.; Ristori, P. R.; Riviére, A.; Rivoire, S.; Rob, L.; Roeser, U.; Rohlfs, R.; Rojas, G.; Romano, P.; Romaszkan, W.; Romero, G. E.; Rosen, S.; Rosier Lees, S.; Ross, D.; Rouaix, G.; Rousselle, J.; Rousselle, S.; Rovero, A. C.; Roy, F.; Royer, S.; Rudak, B.; Rulten, C.; Rupiński, M.; Russo, F.; Ryde, F.; Sacco, B.; Saemann, E. O.; Saggion, A.; Sahakian, V.; Saito, K.; Saito, T.; Saito, Y.; Sakaki, N.; Sakonaka, R.; Salini, A.; Sanchez, F.; Sanchez-Conde, M.; Sandoval, A.; Sandaker, H.; Sant'Ambrogio, E.; Santangelo, A.; Santos, E. M.; Sanuy, A.; Sapozhnikov, L.; Sarkar, S.; Sartore, N.; Sasaki, H.; Satalecka, K.; Sawada, M.; Scalzotto, V.; Scapin, V.; Scarcioffolo, M.; Schafer, J.; Schanz, T.; Schlenstedt, S.; Schlickeiser, R.; Schmidt, T.; Schmoll, J.; Schovanek, P.; Schroedter, M.; Schultz, C.; Schultze, J.; Schulz, A.; Schure, K.; Schwab, T.; Schwanke, U.; Schwarz, J.; Schwarzburg, S.; Schweizer, T.; Schwemmer, S.; Segreto, A.; Seiradakis, J.-H.; Sembroski, G. H.; Seweryn, K.; Sharma, M.; Shayduk, M.; Shellard, R. C.; Shi, J.; Shibata, T.; Shibuya, A.; Shum, E.; Sidoli, L.; Sidz, M.; Sieiro, J.; Sikora, M.; Silk, J.; Sillanpää, A.; Singh, B. B.; Sitarek, J.; Skole, C.; Smareglia, R.; Smith, A.; Smith, D.; Smith, J.; Smith, N.; Sobczyńska, D.; Sol, H.; Sottile, G.; Sowiński, M.; Spanier, F.; Spiga, D.; Spyrou, S.; Stamatescu, V.; Stamerra, A.; Starling, R.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Steiner, S.; Stergioulas, N.; Sternberger, R.; Sterzel, M.; Stinzing, F.; Stodulski, M.; Straumann, U.; Strazzeri, E.; Stringhetti, L.; Suarez, A.; Suchenek, M.; Sugawara, R.; Sulanke, K.-H.; Sun, S.; Supanitsky, A. D.; Suric, T.; Sutcliffe, P.; Sykes, J.; Szanecki, M.; Szepieniec, T.; Szostek, A.; Tagliaferri, G.; Tajima, H.; Takahashi, H.; Takahashi, K.; Takalo, L.; Takami, H.; Talbot, G.; Tammi, J.; Tanaka, M.; Tanaka, S.; Tasan, J.; Tavani, M.; Tavernet, J.-P.; Tejedor, L. A.; Telezhinsky, I.; Temnikov, P.; Tenzer, C.; Terada, Y.; Terrier, R.; Teshima, M.; Testa, V.; Tezier, D.; Thuermann, D.; Tibaldo, L.; Tibolla, O.; Tiengo, A.; Tluczykont, M.; Todero Peixoto, C. J.; Tokanai, F.; Tokarz, M.; Toma, K.; Torii, K.; Tornikoski, M.; Torres, D. F.; Torres, M.; Tosti, G.; Totani, T.; Toussenel, F.; Tovmassian, G.; Travnicek, P.; Trifoglio, M.; Troyano, I.; Tsinganos, K.; Ueno, H.; Umehara, K.; Upadhya, S. S.; Usher, T.; Uslenghi, M.; Valdes-Galicia, J. F.; Vallania, P.; Vallejo, G.; van Driel, W.; van Eldik, C.; Vandenbrouke, J.; Vanderwalt, J.; Vankov, H.; Vasileiadis, G.; Vassiliev, V.; Veberic, D.; Vegas, I.; Vercellone, S.; Vergani, S.; Veyssiére, C.; Vialle, J. P.; Viana, A.; Videla, M.; Vincent, P.; Vincent, S.; Vink, J.; Vlahakis, N.; Vlahos, L.; Vogler, P.; Vollhardt, A.; von Gunten, H.-P.; Vorobiov, S.; Vuerli, C.; Waegebaert, V.; Wagner, R.; Wagner, R. G.; Wagner, S.; Wakely, S. P.; Walter, R.; Walther, T.; Warda, K.; Warwick, R.; Wawer, P.; Wawrzaszek, R.; Webb, N.; Wegner, P.; Weinstein, A.; Weitzel, Q.; Welsing, R.; Werner, M.; Wetteskind, H.; White, R.; Wierzcholska, A.; Wiesand, S.; Wilkinson, M.; Williams, D. A.; Willingale, R.; Winiarski, K.; Wischnewski, R.; Wiśniewski, Ł.; Wood, M.; Wörnlein, A.; Xiong, Q.; Yadav, K. K.; Yamamoto, H.; Yamamoto, T.; Yamazaki, R.; Yanagita, S.; Yebras, J. M.; Yelos, D.; Yoshida, A.; Yoshida, T.; Yoshikoshi, T.; Zabalza, V.; Zacharias, M.; Zajczyk, A.; Zanin, R.; Zdziarski, A.; Zech, A.; Zhao, A.; Zhou, X.; Ziętara, K.; Ziolkowski, J.; Ziółkowski, P.; Zitelli, V.; Zurbach, C.; Żychowski, P.; CTA Consortium

    2013-03-01

    The Cherenkov Telescope Array (CTA) is a new observatory for very high-energy (VHE) gamma rays. CTA has ambitions science goals, for which it is necessary to achieve full-sky coverage, to improve the sensitivity by about an order of magnitude, to span about four decades of energy, from a few tens of GeV to above 100 TeV with enhanced angular and energy resolutions over existing VHE gamma-ray observatories. An international collaboration has formed with more than 1000 members from 27 countries in Europe, Asia, Africa and North and South America. In 2010 the CTA Consortium completed a Design Study and started a three-year Preparatory Phase which leads to production readiness of CTA in 2014. In this paper we introduce the science goals and the concept of CTA, and provide an overview of the project.

  2. CT Angiography (CTA)

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z CT Angiography (CTA) Computed tomography angiography (CTA) uses an ... are the limitations of CT Angiography? What is CT Angiography? Angiography is a minimally invasive medical test ...

  3. Blunt cerebrovascular injury screening with 64-channel multidetector computed tomography: more slices finally cut it.

    PubMed

    Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A

    2014-02-01

    Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.

  4. High prevalence of intracranial aneurysms in patients with aortic dissection or aneurysm: feasibility of extended aorta CT angiography with involvement of intracranial arteries.

    PubMed

    Lee, Dahye; Ahn, Sung Jun; Cho, Eun-Suk; Kim, Yong Bae; Song, Suk-Won; Jung, Woo Sang; Suh, Sang Hyun

    2017-10-01

    Previous studies have suggested a higher prevalence of intracranial aneurysms (IAs) in patients with aortic aneurysms (AAs). To carry out a preliminary study to evaluate the prevalence of IAs in these patients and the diagnostic feasibility of extended aorta CT angiography (CTA), including intracranial arteries as well as the aorta. We retrospectively reviewed all patients with a clinical diagnosis of AA or aortic dissection (AD) who had undergone aorta CTA as well as MR angiography, CTA, and/or DSA of the brain between 2009 and 2014. Since 2012, the extended aorta CTA protocol has been applied in these patients. Characteristics of IAs were classified with baseline clinical data. For quantitative and qualitative assessment by two independent raters, brain images obtained by extended aorta CTA and brain CTA were compared. The radiation dose of the two aorta protocols was compared. The prevalence of IA was 22.2% (35/158). All IAs were detected by extended aorta CTA, except one small aneurysm (<3 mm). The mean vascular attenuation value between brain images showed no difference (p=0.83), but the contrast-to-noise ratio was significantly lower in extended aorta CTA (p<0.001). In qualitative assessment, the interobserver agreement was substantial (k=0.79). For the radiation dose, the dose-length product of the extended aorta CTA increased with increment of the scan range (p=0.048). With a high prevalence of IAs in patients with ADs or AAs, extended aorta CTA could be used to evaluate aorta disease and IA in a single session. However, further prospective studies are needed to prove efficacy and safety of the extended aorta CTA protocol in patients with AAs or ADs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Cost and resource utilization associated with use of computed tomography to evaluate chest pain in the emergency department: the Rule Out Myocardial Infarction using Computer Assisted Tomography (ROMICAT) study.

    PubMed

    Hulten, Edward; Goehler, Alexander; Bittencourt, Marcio Sommer; Bamberg, Fabian; Schlett, Christopher L; Truong, Quynh A; Nichols, John; Nasir, Khurram; Rogers, Ian S; Gazelle, Scott G; Nagurney, John T; Hoffmann, Udo; Blankstein, Ron

    2013-09-01

    Coronary computed tomographic angiography (cCTA) allows rapid, noninvasive exclusion of obstructive coronary artery disease (CAD). However, concern exists whether implementation of cCTA in the assessment of patients presenting to the emergency department with acute chest pain will lead to increased downstream testing and costs compared with alternative strategies. Our aim was to compare observed actual costs of usual care (UC) with projected costs of a strategy including early cCTA in the evaluation of patients with acute chest pain in the Rule Out Myocardial Infarction Using Computer Assisted Tomography I (ROMICAT I) study. We compared cost and hospital length of stay of UC observed among 368 patients enrolled in the ROMICAT I study with projected costs of management based on cCTA. Costs of UC were determined by an electronic cost accounting system. Notably, UC was not influenced by cCTA results because patients and caregivers were blinded to the cCTA results. Costs after early implementation of cCTA were estimated assuming changes in management based on cCTA findings of the presence and severity of CAD. Sensitivity analysis was used to test the influence of key variables on both outcomes and costs. We determined that in comparison with UC, cCTA-guided triage, whereby patients with no CAD are discharged, could reduce total hospital costs by 23% (P<0.001). However, when the prevalence of obstructive CAD increases, index hospitalization cost increases such that when the prevalence of ≥ 50% stenosis is >28% to 33%, the use of cCTA becomes more costly than UC. cCTA may be a cost-saving tool in acute chest pain populations that have a prevalence of potentially obstructive CAD <30%. However, increased cost would be anticipated in populations with higher prevalence of disease.

  6. Predicting Intracerebral Hemorrhage Growth With the Spot Sign: The Effect of Onset-to-Scan Time.

    PubMed

    Dowlatshahi, Dar; Brouwers, H Bart; Demchuk, Andrew M; Hill, Michael D; Aviv, Richard I; Ufholz, Lee-Anne; Reaume, Michael; Wintermark, Max; Hemphill, J Claude; Murai, Yasuo; Wang, Yongjun; Zhao, Xingquan; Wang, Yilong; Li, Na; Sorimachi, Takatoshi; Matsumae, Mitsunori; Steiner, Thorsten; Rizos, Timolaos; Greenberg, Steven M; Romero, Javier M; Rosand, Jonathan; Goldstein, Joshua N; Sharma, Mukul

    2016-03-01

    Hematoma expansion after acute intracerebral hemorrhage is common and is associated with early deterioration and poor clinical outcome. The computed tomographic angiography (CTA) spot sign is a promising predictor of expansion; however, frequency and predictive values are variable across studies, possibly because of differences in onset-to-CTA time. We performed a patient-level meta-analysis to define the relationship between onset-to-CTA time and frequency and predictive ability of the spot sign. We completed a systematic review for studies of CTA spot sign and hematoma expansion. We subsequently pooled patient-level data on the frequency and predictive values for significant hematoma expansion according to 5 predefined categorized onset-to-CTA times. We calculated spot-sign frequency both as raw and frequency-adjusted rates. Among 2051 studies identified, 12 met our inclusion criteria. Baseline hematoma volume, spot-sign status, and time-to-CTA were available for 1176 patients, and 1039 patients had follow-up computed tomographies for hematoma expansion analysis. The overall spot sign frequency was 26%, decreasing from 39% within 2 hours of onset to 13% beyond 8 hours (P<0.001). There was a significant decrease in hematoma expansion in spot-positive patients as onset-to-CTA time increased (P=0.004), with positive predictive values decreasing from 53% to 33%. The frequency of the CTA spot sign is inversely related to intracerebral hemorrhage onset-to-CTA time. Furthermore, the positive predictive value of the spot sign for significant hematoma expansion decreases as time-to-CTA increases. Our results offer more precise risk stratification for patients with acute intracerebral hemorrhage and will help refine clinical prediction rules for intracerebral hemorrhage expansion. © 2016 American Heart Association, Inc.

  7. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    PubMed

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  8. Lower gastrointestinal bleeding: Role of 64-row computed tomographic angiography in diagnosis and therapeutic planning

    PubMed Central

    Ren, Jian-Zhuang; Zhang, Meng-Fan; Rong, Ai-Mei; Fang, Xiang-Jie; Zhang, Kai; Huang, Guo-Hao; Chen, Peng-Fei; Wang, Zhao-Yang; Duan, Xu-Hua; Han, Xin-Wei; Liu, Yan-Jie

    2015-01-01

    AIM: To determine the value of computed tomographic angiography (CTA) for diagnosis and therapeutic planning in lower gastrointestinal (GI) bleeding. METHODS: Sixty-three consecutive patients with acute lower GI bleeding underwent CTA before endovascular or surgical treatment. CTA was used to determine whether the lower GI bleeding was suitable for endovascular treatment, surgical resection, or conservative treatment in each patient. Treatment planning with CTA was compared with actual treatment decisions or endovascular or surgical treatment that had been carried out in each patient based on CTA findings. RESULTS: 64-row CTA detected active extravasation of contrast material in 57 patients and six patients had no demonstrable active bleeding, resulting in an accuracy of 90.5% in the detection of acute GI bleeding (57 of 63). In three of the six patients with no demonstrable active bleeding, active lower GI bleeding recurred within one week after CTA, and angiography revealed acute bleeding. The overall location-based accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the detection of GI bleeding by 64-row CTA were 98.8% (249 of 252), 95.0% (57 of 60), 100% (192 of 192), 100% (57 of 57), and 98.5% (192 of 195), respectively. Treatment planning was correctly established on the basis of 64-row CTA with an accuracy, sensitivity, specificity, PPV and NPV of 98.4% (248 of 252), 93.3% (56 of 60), 100% (192 of 192), 100% (56 of 56), and 97.5% (192 of 196), respectively, in a location-based evaluation. CONCLUSION: 64-row CTA is safe and effective in making decisions regarding treatment, without performing digital subtraction angiography or surgery, in the majority of patients with lower GI bleeding. PMID:25852291

  9. Evaluation of intra-aortic CT angiography performances for the visualisation of spinal vascular malformations' angioarchitecture.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Sourour, Nader-Antoine; Gabrieli, Joseph; Nouet, Aurélien; Shotar, Eimad; Cormier, Evelyne; Fahed, Robert; Cornu, Philippe; Chiras, Jacques

    2016-10-01

    To evaluate the performances of the CT-angiography by direct intra-aortic contrast media injection (IA-CTA) for spinal vascular malformations (SVMs)' imaging. Thirteen patients (8 males, 5 females, mean age: 56 y) with suspected SVM underwent IA-CTAs by direct intra-aortic iodinated contrast media injection (5 cc/s; 100 cc) via an arterial femoral or humeral access. Two independent observers evaluated the angioarchitecture of the SVMs and the visualisation of both the Adamkiewicz artery and the anterior spinal artery. Then a consensus was obtained between the 2 reviewers; the results of the IA-CTA were finally compared with those of the full spinal DSA evaluated in consensus. The IA-CTA was feasible in all cases and depicted the SVM in all except one case (92 %). Interrater agreement was good for the location of the SVMs' level. Intermodality (IA-CTA/DSA) agreement was excellent for the level and side of the shunt point, as well as for the SVM subtype evaluation. In 77 % of the cases, the Adamkiewicz artery was satisfactorily seen at the same time on IA-CTA. IA-CTA is a new technique that seems helpful to reach a better understanding of SMVs and may help to tailor more precisely their treatment. • IA-CTA is an accurate technique for the SVMs' angioarchitecture analysis • IA-CTA can locate, at the same time, the Adamkiewicz artery (AKA) • IA-CTA may be helpful in elderly patients with troublesome vasculature.

  10. Adapting Cognitive Task Analysis to Investigate Clinical Decision Making and Medication Safety Incidents.

    PubMed

    Russ, Alissa L; Militello, Laura G; Glassman, Peter A; Arthur, Karen J; Zillich, Alan J; Weiner, Michael

    2017-05-03

    Cognitive task analysis (CTA) can yield valuable insights into healthcare professionals' cognition and inform system design to promote safe, quality care. Our objective was to adapt CTA-the critical decision method, specifically-to investigate patient safety incidents, overcome barriers to implementing this method, and facilitate more widespread use of cognitive task analysis in healthcare. We adapted CTA to facilitate recruitment of healthcare professionals and developed a data collection tool to capture incidents as they occurred. We also leveraged the electronic health record (EHR) to expand data capture and used EHR-stimulated recall to aid reconstruction of safety incidents. We investigated 3 categories of medication-related incidents: adverse drug reactions, drug-drug interactions, and drug-disease interactions. Healthcare professionals submitted incidents, and a subset of incidents was selected for CTA. We analyzed several outcomes to characterize incident capture and completed CTA interviews. We captured 101 incidents. Eighty incidents (79%) met eligibility criteria. We completed 60 CTA interviews, 20 for each incident category. Capturing incidents before interviews allowed us to shorten the interview duration and reduced reliance on healthcare professionals' recall. Incorporating the EHR into CTA enriched data collection. The adapted CTA technique was successful in capturing specific categories of safety incidents. Our approach may be especially useful for investigating safety incidents that healthcare professionals "fix and forget." Our innovations to CTA are expected to expand the application of this method in healthcare and inform a wide range of studies on clinical decision making and patient safety.

  11. Exploring the Effect of Video Used to Enhance the Retrospective Verbal Protocol Analysis: A Multiple Case Study

    ERIC Educational Resources Information Center

    Monroe, Steven D.

    2012-01-01

    The purpose of this study was to explore how the use of video in the cognitive task analysis (CTA) retrospective verbal protocol analysis (RVPA) during a job analysis affects: (a) the quality of performing the CTA, (b) the time to complete the CTA, and (c) the cost to execute the CTA. Research has shown when using the simultaneous VPA during a CTA…

  12. CRTS-II Detection of Increased Optical Activity from CTA 102

    NASA Astrophysics Data System (ADS)

    Djorgovski, S. G.; Drake, A. J.; Mahabal, A. A.; Graham, M. J.; Christensen, E.; Larson, S. M.

    2017-12-01

    We report the detection of significant optical brightening of FSRQ CTA 102 by CRTS-II on 2017 Dec. 8.15 UT. At that time CTA 102 was seen to have risen approximately 1.4 mags (to V_CSS = 14.15) compared with previous observations taken on 2017 Nov. 23 UT. Additional survey observations taken on 2017 Dec. 15 UT show CTA 102 at V_CSS = 14.05.

  13. Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors.

    PubMed

    Bhatti, Aftab A; Chugtai, Aamir; Haslam, Philip; Talbot, David; Rix, David A; Soomro, Naeem A

    2005-11-01

    To prospectively compare the accuracy of multislice spiral computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) in evaluating the renal vascular anatomy in potential living renal donors. Thirty-one donors underwent multislice spiral CTA and gadolinium-enhanced MRA. In addition to axial images, multiplanar reconstruction and maximum intensity projections were used to display the renal vascular anatomy. Twenty-four donors had a left laparoscopic donor nephrectomy (LDN), whereas seven had right open donor nephrectomy (ODN); LDN was only considered if the renal vascular anatomy was favourable on the left. CTA and MRA images were analysed by two radiologists independently. The radiological and surgical findings were correlated after the surgery. CTA showed 33 arteries and 32 veins (100% sensitivity) whereas MRA showed 32 arteries and 31 veins (97% sensitivity). CTA detected all five accessory renal arteries whereas MRA only detected one. CTA also identified all three accessory renal veins whereas MRA identified two. CTA had a sensitivity of 97% and 47% for left lumbar and left gonadal veins, whereas MRA had a sensitivity of 74% and 46%, respectively. Multislice spiral CTA with three-dimensional reconstruction was more accurate than MRA for both renal arterial and venous anatomy.

  14. The immune complex CTA1-DD/IgG adjuvant specifically targets connective tissue mast cells through FcγRIIIA and augments anti-HPV immunity after nasal immunization.

    PubMed

    Fang, Y; Zhang, T; Lidell, L; Xu, X; Lycke, N; Xiang, Z

    2013-11-01

    We have previously reported that CTA1-DD/IgG immune complexes augment antibody responses in a mast cell-dependent manner following intranasal (IN) immunizations. However, from a safety perspective, mast cell activation could preclude clinical use. Therefore, we have extended these studies and demonstrate that CTA1-DD/IgG immune complexes administered IN did not trigger an anaphylactic reaction. Importantly, CTA1-DD/IgE immune complexes did not activate mast cells. Interestingly, only connective tissue, but not mucosal, mast cells could be activated by CTA1-DD/IgG immune complexes. This effect was mediated by FcγRIIIA, only expressed on connective tissue mast cells, and found in the nasal submucosa. FcγRIIIA-deficient mice had compromised responses to immunization adjuvanted by CTA1-DD/IgG. Proof-of-concept studies revealed that IN immunized mice with human papillomavirus (HPV) type 16 L1 virus-like particles (VLP) and CTA1-DD/IgG immune complexes demonstrated strong and sustained specific antibody titers in serum and vaginal secretions. From a mast cell perspective, CTA1-DD/IgG immune complexes appear to be safe and effective mucosal adjuvants.

  15. Cognitive task analysis for instruction in single-injection ultrasound guided-regional anesthesia

    NASA Astrophysics Data System (ADS)

    Gucev, Gligor V.

    Cognitive task analysis (CTA) is methodology for eliciting knowledge from subject matter experts. CTA has been used to capture the cognitive processes, decision-making, and judgments that underlie expert behaviors. A review of the literature revealed that CTA has not yet been used to capture the knowledge required to perform ultrasound guided regional anesthesia (UGRA). The purpose of this study was to utilize CTA to extract knowledge from UGRA experts and to determine whether instruction based on CTA of UGRA will produce results superior to the results of traditional training. This study adds to the knowledge base of CTA in being the first one to effectively capture the expert knowledge of UGRA. The derived protocol was used in a randomized, double blinded experiment involving UGRA instruction to 39 novice learners. The results of this study strongly support the hypothesis that CTA-based instruction in UGRA is more effective than conventional clinical instruction, as measured by conceptual pre- and post-tests, performance of a simulated UGRA procedure, and time necessary for the task performance. This study adds to the number of studies that have proven the superiority of CTA-informed instruction. Finally, it produced several validated instruments that can be used in instructing and evaluating UGRA.

  16. Investigating motion sickness using the conditioned taste aversion paradigm

    NASA Technical Reports Server (NTRS)

    Fox, Robert A.

    1990-01-01

    The use of conditioned taste aversion (CTA) to study motion sickness is reviewed. The use of CTA to measure motion sickness is supported by studies showing that an intact vestibular system is essential for the production of CTA when motion is the unconditioned stimulus. The magnitude of CTA is assessed at a time removed from exposure to motion, and therefore is not affected by residual effects of motion. Since the magnitude of CTA is assessed as volume or weight of flood or fluid, the degree of sickness is reflected in a continuous measure rather than in the discrete, all-or-none fashion characteristic of vomiting.

  17. Angiographic findings and clinical outcomes in asymptomatic patients with severe obstructive atherosclerosis on computed tomography angiography.

    PubMed

    Kornowski, Ran; Bachar, Gil N; Dvir, Danny; Fuchs, Shmuel; Atar, Eli

    2008-01-01

    Cardiac computed tomography angiography is a relatively new imaging modality to detect coronary atherosclerosis. To explore the diagnostic value of CTA in assessing coronary artery disease among asymptomatic patients. In this retrospective single-centered analysis, 622 consecutive patients underwent CTA of coronary arteries between November 2004 and May 2006 at the Mor Institute for Cardiovascular Imaging in Bnei Brak, Israel. All patients were asymptomatic but had at least one risk factor for atherosclerotic CAD. The initial 244 patients were examined with the 16-slice Brilliance CT scanner (Philips, Cleveland, OH, U.S.A.), and in the remaining 378 patients the 64-slice scanner (GE Healthcare, The Netherlands) with dedicated cardiac reconstruction software and electrocardiography triggering was used. Scanning was performed in the cranio-caudal direction. Images reconstructed in different phases of the cardiac cycle using a retrospective ECG-gated reconstruction algorithm were transferred to a dedicated workstation for review by experienced CT radiologists and cardiologists. Of 622 patients, 52 (8.4%) had severe obstructive atherosclerosis (suspected > or = 75% stenosis) according to CTA interpretation. Invasive coronary angiography was performed in 48 patients while 4 patients had no further procedure. A non-significant CAD (e.g., diameter stenosis < 70%) was identified in 6 of 48 patients (12%) by selective coronary angiography. Forty-two patients showed severe CAD with at least one lesion of 70% stenosis. Percutaneous coronary intervention was performed in 35 patients and coronary artery bypass grafting surgery in the other 4 patients. Angioplasty procedures were successful in all 35 patients and stents were utilized in all cases without complications. No further complications occurred among the study cohort undergoing either PCI or surgery. The 6 month survival rate in these patients was 100%. Non-invasive coronary CTA appears to be a reliable technique, with reasonably high accuracy, to detect obstructive atherosclerosis in asymptomatic high risk patients for atherosclerotic CAD.

  18. Intravascular ultrasound is a critical tool for accurate endograft sizing in the management of blunt thoracic aortic injury.

    PubMed

    Wallace, Gabriel A; Starnes, Benjamin W; Hatsukami, Thomas S; Sobel, Michael; Singh, Niten; Tran, Nam T

    2015-03-01

    Accurate measurement of true aortic luminal diameter (ALD) is critical for endograft sizing in endovascular treatment of blunt thoracic aortic injury (BTAI), but ALD is dynamic and changes with respect to patients' hemodynamic status. This study aimed to characterize how ALD at the time of diagnosis of BTAI compares with ALD at the time of endovascular repair and later at follow-up. This is an Institutional Review Board-approved, single-institution retrospective analysis of prospectively obtained data. Patients were included who presented between July 2007 and December 2012 with computed tomography angiography (CTA)-diagnosed BTAI; who underwent thoracic endovascular aortic repair (TEVAR); and who underwent preoperative CTA, intraoperative intravascular ultrasound (IVUS), and postimplantation CTA. Comparison measurements of the ALD were made among CTA and IVUS images at the level of the left subclavian artery (LSCA) and between initial CTA and postimplantation CTA at 10, 15, and 20 cm distal to the LSCA. Theoretical endograft sizes were determined and compared for each ALD at the LSCA. Twenty-two patients were included in the analysis. Mean age was 38 ± 14 years (range, 17-61 years), with 82% men and mean Injury Severity Score of 43 ± 11 (range, 24-66). Mean time from emergency department admission to initial CTA was -1.2 ± 5 hours (range, -13 to 11.5 hours; negative time implies imaging at an outside facility before admission). Mean time from initial CTA to IVUS was 1.2 ± 1.4 days (range, 2.5 hours-5.7 days) and from IVUS to postimplantation CTA 33 ± 45 days (range, 17 hours-169 days). Overall, ALD measured by IVUS was significantly larger than that by initial CTA (Δ2.5 ± 3.1 mm; P < .05). ALD was also larger at 10, 15, and 20 cm distal to the LSCA in comparing the postimplantation CTA with the initial CTA (Δ2.4, 2.0, and 2.0 mm, respectively; all P < .05). More than half the devices would be sized differently with ALD measured by IVUS at the time of TEVAR vs initial CTA. The ALD of patients with BTAI is significantly larger when it is measured by IVUS at the time of TEVAR compared with at the time of initial CTA. This difference in ALD may translate to undersizing of endografts used in TEVAR for BTAI. IVUS at the time of TEVAR provides a more accurate measurement of the actual ALD and should be used for endograft sizing for patients with BTAI. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  19. End Tidal Carbon Dioxide as a Screening Tool for Computed Tomography Angiogram in Postoperative Orthopaedic Patients Suspected of Pulmonary Embolism.

    PubMed

    Ramme, Austin J; Iturrate, Eduardo; Dweck, Ezra; Steiger, David J; Hutzler, Lorraine H; Fang, Yixin; Wang, Binhuan; Bosco, Joseph A; Sigmund, Alana E

    2016-10-01

    Computed tomography pulmonary angiography (CTA) is the gold standard for diagnosing pulmonary embolism (PE) but involves radiation and iodinated contrast exposure. Of orthopedic patients evaluated for PE, a minority have a positive CTA study. Herein, we evaluate end tidal carbon dioxide (ETCO2) as a method to identify patients at low risk for PE and may not require a CTA. We hypothesize that ETCO2 will be useful for predicting the absence of PE in postoperative orthopedic patients. In this prospective study, all patients older than 18 years who were admitted for orthopedic surgery and who had a CTA performed for PE were eligible. These patients underwent an ETCO2 measurement. Patients were determined to have PE if they had a positive PE-protocol CT. Between May 2014 and April 2015, 121 patients met the inclusion criteria for the study. Of these patients, 84 had a negative CTA examination, 25 had a positive examination, and 12 had a nondiagnostic examination. We found a statistically significant difference (P = .03) when comparing the average ETCO2 values for the positive and negative CTA groups. An ETCO2 cutoff value of 43 mm Hg was 100% sensitive with a negative predictive value of 100% for absence of PE on CTA. This study demonstrates a significant difference in ETCO2 measurements between postoperative orthopedic patients with and without CTA-detected PE. A cutoff value of >43 mm Hg may be useful in excluding patients from undergoing CTA. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Vascular Assessment for Transcatheter Aortic Valve Replacement: Intravascular Ultrasound Compared With Computed Tomography.

    PubMed

    Essa, Essa; Makki, Nader; Bittenbender, Peter; Capers, Quinn; George, Barry; Rushing, Gregory; Crestanello, Juan; Boudoulas, Konstantinos Dean; Lilly, Scott M

    2016-12-01

    Assessment of the femoral and iliac arteries is essential prior to transcatheter aortic valve replacement (TAVR). It is critical for establishing candidacy for a femoral approach, and can help predict vascular complications. Although computed tomography angiography (CTA) is the standard imaging modality, it has limitations. This study compared CTA with intravascular ultrasound (IVUS) in patients undergoing TAVR evaluation. Fifteen patients undergoing pre-TAVR coronary angiography and hemodynamic assessment were recruited. Following coronary angiography, patients underwent distal aortography, bilateral iliac and femoral arteriography, and IVUS assessment. Vascular tortuosity, minimum lumen diameter, and cross-sectional area were obtained and the findings were compared with those obtained from CTA. Correlation between IVUS and CTA was strong for minimum luminal diameter (r=0.62). Concordance was also strong between CTA and invasive iliofemoral angiography for assessment of tortuosity (r=0.75). Utilizing Bland-Altman analysis, vessel diameters obtained by IVUS were consistently greater than those obtained by CTA. The angiography and IVUS strategy was associated with a lower overall mean contrast utilization (29 cc vs 100 cc; P<.001), reduced mean radiation exposure (527 mGy vs 998 mGy; P=.045), and no significant difference in mean test duration (13.3 minutes vs 10 minutes; P=.12). For femoral and iliac arterial assessment prior to TAVR, IVUS is a viable alternative to CTA with comparable accuracy, and the potential for less contrast use and less radiation exposure. IVUS is also a valuable adjunct to CTA in patients with borderline femoral access diameters or considerable CTA artifacts.

  1. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    PubMed

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Risks and benefits of CT angiography in spontaneous intracerebral hemorrhage.

    PubMed

    Hotta, Kazuko; Sorimachi, Takatoshi; Osada, Takahiro; Baba, Tanefumi; Inoue, Go; Atsumi, Hideki; Ishizaka, Hideo; Matsuda, Minako; Hayashi, Naokazu; Matsumae, Mitsunori

    2014-05-01

    Few studies have examined the risk of computed tomography angiography (CTA) during the acute phase of spontaneous intracerebral hemorrhage (ICH), while the benefits of CTA in ICH have been well-documented. The present study investigated both the benefits of identifying spot signs, which are supposed to indicate hematoma enlargement after admission, and risks of CTA performed during the acute phase of ICH. We retrospectively assessed 323 consecutive patients with spontaneous ICHs admitted to our hospital between April 2009 and March 2012 and who underwent CTA on admission. In 80 patients (24.7 %), spot signs were demonstrated on CTA source images. Multivariate analysis revealed two independent factors correlated with presence of the spot sign: age and hematoma volume (p < 0.05 each). The presence of spot sign was associated with unfavorable outcomes at discharge and hematoma growth after admission (p < 0.05 each). Adverse events related to CTA occurred in 17 patients (5.2 %), including transient renal dysfunction in 16 patients and allergy to contrast medium in one patient. All adverse events completely resolved within 1 week. Presence of the spot sign indicated the possibility of hematoma growth and unfavorable outcomes. A small number of adverse events occurred in association with CTA, but without any permanent deficits. Given the potential benefits and risks, we believe that CTA performed at admission in all patients with ICH is beneficial to improve the outcomes.

  3. 3D/3D registration of coronary CTA and biplane XA reconstructions for improved image guidance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dibildox, Gerardo, E-mail: g.dibildox@erasmusmc.nl; Baka, Nora; Walsum, Theo van

    2014-09-15

    Purpose: The authors aim to improve image guidance during percutaneous coronary interventions of chronic total occlusions (CTO) by providing information obtained from computed tomography angiography (CTA) to the cardiac interventionist. To this end, the authors investigate a method to register a 3D CTA model to biplane reconstructions. Methods: The authors developed a method for registering preoperative coronary CTA with intraoperative biplane x-ray angiography (XA) images via 3D models of the coronary arteries. The models are extracted from the CTA and biplane XA images, and are temporally aligned based on CTA reconstruction phase and XA ECG signals. Rigid spatial alignment ismore » achieved with a robust probabilistic point set registration approach using Gaussian mixture models (GMMs). This approach is extended by including orientation in the Gaussian mixtures and by weighting bifurcation points. The method is evaluated on retrospectively acquired coronary CTA datasets of 23 CTO patients for which biplane XA images are available. Results: The Gaussian mixture model approach achieved a median registration accuracy of 1.7 mm. The extended GMM approach including orientation was not significantly different (P > 0.1) but did improve robustness with regards to the initialization of the 3D models. Conclusions: The authors demonstrated that the GMM approach can effectively be applied to register CTA to biplane XA images for the purpose of improving image guidance in percutaneous coronary interventions.« less

  4. Memory trace reactivation and behavioral response during retrieval are differentially modulated by amygdalar glutamate receptors activity: interaction between amygdala and insular cortex

    PubMed Central

    Osorio-Gómez, Daniel; Guzmán-Ramos, Kioko

    2017-01-01

    The insular cortex (IC) is required for conditioned taste aversion (CTA) retrieval. However, it remains unknown which cortical neurotransmitters levels are modified upon CTA retrieval. Using in vivo microdialysis, we observed that there were clear elevations in extracellular glutamate, norepinephrine, and dopamine in and around the center of the gustatory zone of the IC during CTA retrieval. Additionally, it has been reported that the amygdala–IC interaction is highly involved in CTA memory establishment. Therefore, we evaluated the effects of infusions of an AMPA receptor antagonist (CNQX) and a NMDA receptor antagonist (APV) into the amygdala on CTA retrieval and IC neurotransmitter levels. Infusion of APV into the amygdala impaired glutamate augmentation within the IC, whereas dopamine and norepinephrine levels augmentation persisted and a reliable CTA expression was observed. Conversely, CNQX infusion into the amygdala impaired the aversion response, as well as norepinephrine and dopamine augmentations in the IC. Interestingly, CNQX infusion did not affect glutamate elevation in the IC. To evaluate the functional meaning of neurotransmitters elevations within the IC on CTA response, we infused specific antagonists for the AMPA, NMDA, D1, and β-adrenergic receptor before retrieval. Results showed that activation of AMPA, D1, and β-adrenergic receptors is necessary for CTA expression, whereas NMDA receptors are not involved in the aversion response. PMID:27980072

  5. Preparation of gold nanoparticles by surfactant-promoted reductive reaction without extra reducing agent.

    PubMed

    Tang, Junqi; Huang, Jiamin; Man, Shi-Qing

    2013-02-15

    Cetyltrimethyl ammonium bromide (CTAB) has been extensively applied in the solution-phase synthesis of many types of colloidal nanoparticles. However, the uses of CTAB were mainly considered as template or capping agents to form controllable shape and protect the product from agglomeration. Here it was discovered that CATB could serve as a very mild reductant to reduce gold salt precursors preparing gold nanoparticles (GNPs) at base environment. CTAB acted as the reducing agent suffering a partial degradation and forming CTA macro radicals. FTIR proved the formation of CCl and/or CBr bond after CTAB degraded. The characterization of synthesized GNPs was examined by UV-Vis spectra, TEM and XRD. Several factors affecting the process of reaction, such as the amount of NaOH, the molar ratio of CTAB and HAuCl(4), the reaction temperature, the effect of light and oxygen, and stirring were discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Potential impact of clinical use of noninvasive FFRCT on radiation dose exposure and downstream clinical event rate.

    PubMed

    Bilbey, Nicolas; Blanke, Philipp; Naoum, Christopher; Arepalli, Chesnel Dey; Norgaard, Bjarne Linde; Leipsic, Jonathon

    2016-01-01

    This study aims to determine the potential impact of introducing noninvasive fractional flow reserve based on coronary computed tomography angiography (CTA) into clinical practice, with respect to radiation dose exposure and downstream event rate. We modeled a population of 1000 stable, symptomatic patients with suspected coronary artery disease, using the disease prevalence from the CONFIRM registry to estimate the pretest likelihood. Four potential clinical pathways were modeled based on the first noninvasive diagnostic test performed: (1) dobutamine echo; (2) single-photon emission computerized tomography (SPECT); (3) coronary CTA; and (4) CTA+FFRCT and leading to possible invasive coronary angiography. The posttest likelihood of testing positive/negative by each test was based on the presenting disease burden and diagnostic accuracy of each test. The dobutamine echo pathway resulted in the lowest radiation dose of 5.4 mSv, with 4.0 mSv from angiography and 1.4 mSv from percutaneous coronary intervention (PCI). The highest dose was with SPECT, with 26.5 mSv. The coronary computed tomography angiography (cCTA) pathway demonstrated a dose of 14.2 mSv, 3.7 mSv from cCTA, 7.7 mSv from angiography, and 2.8 mSv from PCI. The CTA+FFRCT pathway exhibited a radiation dose of 9.7 mSv, 3.7 mSv for cCTA, 4.2 mSv for angiography, and 1.8 mSv for PCI. Radiation dose exposure for CTA+FFRCT was lower than for SPECT (P<.001). The CTA+FFRCT pathway resulted in the lowest projected death/myocardial infarction rate at 1 year (2.44%) while the dobutamine stress pathway had the highest 1-year event rate (2.84%). Our analysis suggests that integrating FFRCT into the CTA clinical pathway may result in reduced cumulative radiation exposure, while promoting favorable clinical outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Task analysis method for procedural training curriculum development.

    PubMed

    Riggle, Jakeb D; Wadman, Michael C; McCrory, Bernadette; Lowndes, Bethany R; Heald, Elizabeth A; Carstens, Patricia K; Hallbeck, M Susan

    2014-06-01

    A central venous catheter (CVC) is an important medical tool used in critical care and emergent situations. Integral to proper care in many circumstances, insertion of a CVC introduces the risk of central line-associated blood stream infections and mechanical adverse events; proper training is important for safe CVC insertion. Cognitive task analysis (CTA) methods have been successfully implemented in the medical field to improve the training of postgraduate medical trainees, but can be very time-consuming to complete and require a significant time commitment from many subject matter experts (SMEs). Many medical procedures such as CVC insertion are linear processes with well-documented procedural steps. These linear procedures may not require a traditional CTA to gather the information necessary to create a training curriculum. Accordingly, a novel, streamlined CTA method designed primarily to collect cognitive cues for linear procedures was developed to be used by medical professionals with minimal CTA training. This new CTA methodology required fewer trained personnel, fewer interview sessions, and less time commitment from SMEs than a traditional CTA. Based on this study, a streamlined CTA methodology can be used to efficiently gather cognitive information on linear medical procedures for the creation of resident training curricula and procedural skills assessments.

  8. Predictive Value of CTA Spot Sign on Hematoma Expansion in Intracerebral Hemorrhage Patients

    PubMed Central

    Peng, Wen-Jie; Reis, Cesar; Reis, Haley

    2017-01-01

    Hematoma expansion (HE) occurs in approximately one-third of patients with intracerebral hemorrhage and leads to high rates of mortality and morbidity. Currently, contrast extravasation within hematoma, termed the spot sign on computed tomography angiography (CTA), has been identified as a strong independent predictor of early hematoma expansion. Past studies indicate that the spot sign is a dynamic entity and is indicative of active hemorrhage. Furthermore, to enhance the spot sign's accuracy of predicting HE, spot parameters observed on CTA or dynamic CTA were used for its quantification. In addition, spot signs detected on multiphase CTA and dynamic CTA are shown to have higher sensitivity and specificity when compared with simple standardized spot sign detection in recent studies. Based on the spot sign, novel methods such as leakage sign and rate of contrast extravasation were explored to redefine HE prediction in combination with clinical characteristics and spot sign on CTA to assist clinical judgment. The spot sign is an accepted independent predictor of active hemorrhage and is used in both secondary intracerebral hemorrhage and the process of surgical assessment for hemorrhagic risk in patients with ischemic stroke. Spot sign predicts patients at high risk for hematoma expansion. PMID:28852647

  9. CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    PubMed

    Foldyna, Borek; Szilveszter, Bálint; Scholtz, Jan-Erik; Banerji, Dahlia; Maurovich-Horvat, Pál; Hoffmann, Udo

    2018-04-01

    Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the presence, extent and composition of coronary atherosclerosis. The CAD-RADS classification is a comprehensive tool for summarising findings on a per-patient-basis dependent on the highest-grade coronary artery lesion, ranging from CAD-RADS 0 (absence of CAD) to CAD-RADS 5 (total occlusion of a coronary artery). In addition, it provides suggestions for clinical management for each classification, including further testing and therapeutic options. Despite some limitations, CAD-RADS may facilitate improved communication between imagers and patient caregivers. As such, CAD-RADS may enable a more efficient use of coronary CTA leading to more accurate utilisation of invasive coronary angiograms. Furthermore, widespread use of CAD-RADS may facilitate registry-based research of diagnostic and prognostic aspects of CTA. • CAD-RADS is a tool for standardising coronary CTA reports. • CAD-RADS includes clinical treatment recommendations based on CTA findings. • CAD-RADS has the potential to reduce variability of CTA reports.

  10. Conditioned taste avoidance induced by forced and voluntary wheel running in rats.

    PubMed

    Forristall, J R; Hookey, B L; Grant, V L

    2007-03-01

    Voluntary exercise by rats running in a freely rotating wheel (free wheel) produces conditioned taste avoidance (CTA) of a flavored solution consumed before running [e.g., Lett, B.T., Grant, V.L., 1996. Wheel running induces conditioned taste aversion in rats trained while hungry and thirsty. Physiol. Behav. 59, 699-702]. Forced exercise, swimming or running, also produces CTA in rats [e.g., Masaki, T., Nakajima, S., 2006. Taste aversion induced by forced swimming, voluntary running, forced running, and lithium chloride injection treatments. Physiol. Behav. 88, 411-416]. Energy expenditure may be the critical factor in producing such CTA. If so, forced running in a motorized running wheel should produce CTA equivalent to that produced by a similar amount of voluntary running. In two experiments, we compared forced running in a motorized wheel with voluntary running in a free wheel. Mean distance run over 30 min was equated as closely as possible in the two apparatuses. Both types of exercise produced CTA relative to sedentary, locked-wheel controls. However, voluntary running produced greater CTA than forced running. We consider differences between running in the free and motorized wheels that may account for the differences in strength of CTA.

  11. Predictive Value of CTA Spot Sign on Hematoma Expansion in Intracerebral Hemorrhage Patients.

    PubMed

    Peng, Wen-Jie; Reis, Cesar; Reis, Haley; Zhang, John; Yang, Jun

    2017-01-01

    Hematoma expansion (HE) occurs in approximately one-third of patients with intracerebral hemorrhage and leads to high rates of mortality and morbidity. Currently, contrast extravasation within hematoma, termed the spot sign on computed tomography angiography (CTA), has been identified as a strong independent predictor of early hematoma expansion. Past studies indicate that the spot sign is a dynamic entity and is indicative of active hemorrhage. Furthermore, to enhance the spot sign's accuracy of predicting HE, spot parameters observed on CTA or dynamic CTA were used for its quantification. In addition, spot signs detected on multiphase CTA and dynamic CTA are shown to have higher sensitivity and specificity when compared with simple standardized spot sign detection in recent studies. Based on the spot sign, novel methods such as leakage sign and rate of contrast extravasation were explored to redefine HE prediction in combination with clinical characteristics and spot sign on CTA to assist clinical judgment. The spot sign is an accepted independent predictor of active hemorrhage and is used in both secondary intracerebral hemorrhage and the process of surgical assessment for hemorrhagic risk in patients with ischemic stroke. Spot sign predicts patients at high risk for hematoma expansion.

  12. Computed tomographic angiography in stroke imaging: fundamental principles, pathologic findings, and common pitfalls.

    PubMed

    Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R

    2006-06-01

    The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.

  13. Application of the dynamically allocated virtual clustering management system to emulated tactical network experimentation

    NASA Astrophysics Data System (ADS)

    Marcus, Kelvin

    2014-06-01

    The U.S Army Research Laboratory (ARL) has built a "Network Science Research Lab" to support research that aims to improve their ability to analyze, predict, design, and govern complex systems that interweave the social/cognitive, information, and communication network genres. Researchers at ARL and the Network Science Collaborative Technology Alliance (NS-CTA), a collaborative research alliance funded by ARL, conducted experimentation to determine if automated network monitoring tools and task-aware agents deployed within an emulated tactical wireless network could potentially increase the retrieval of relevant data from heterogeneous distributed information nodes. ARL and NS-CTA required the capability to perform this experimentation over clusters of heterogeneous nodes with emulated wireless tactical networks where each node could contain different operating systems, application sets, and physical hardware attributes. Researchers utilized the Dynamically Allocated Virtual Clustering Management System (DAVC) to address each of the infrastructure support requirements necessary in conducting their experimentation. The DAVC is an experimentation infrastructure that provides the means to dynamically create, deploy, and manage virtual clusters of heterogeneous nodes within a cloud computing environment based upon resource utilization such as CPU load, available RAM and hard disk space. The DAVC uses 802.1Q Virtual LANs (VLANs) to prevent experimentation crosstalk and to allow for complex private networks. Clusters created by the DAVC system can be utilized for software development, experimentation, and integration with existing hardware and software. The goal of this paper is to explore how ARL and the NS-CTA leveraged the DAVC to create, deploy and manage multiple experimentation clusters to support their experimentation goals.

  14. In vitro cell transformation induced by synthetic amorphous silica nanoparticles.

    PubMed

    Fontana, Caroline; Kirsch, Anaïs; Seidel, Carole; Marpeaux, Léa; Darne, Christian; Gaté, Laurent; Remy, Aurélie; Guichard, Yves

    2017-11-01

    Synthetic amorphous silica nanoparticles (SAS) are among the most widely produced and used nanomaterials, but little is known about their carcinogenic potential. This study aims to evaluate the ability of four different SAS, two precipitated, NM-200 and NM-201, and two pyrogenic, NM-202 and NM-203, to induce the transformation process. For this, we used the recently developed in vitro Bhas 42 cell transformation assay (CTA). The genome of the transgenic Bhas 42 cells contains several copies of the v-Ha-ras gene, making them particularly sensitive to tumor-promoter agents. The Bhas 42 CTA, which includes an initiation assay and a promotion assay, was validated in our laboratory using known soluble carcinogenic substances. Its suitability for particle-type substances was verified by using quartz Min-U-Sil 5 (Min-U-Sil) and diatomaceous earth (DE) microparticles. As expected given their known transforming properties, Min-U-Sil responded positively in the Bhas 42 CTA and DE responded negatively. Transformation assays were performed with SAS at concentrations ranging from 2μg/cm 2 to 80μg/cm 2 . Results showed that all SAS have the capacity to induce transformed foci, interestingly only in the promotion assay, suggesting a mode of action similar to tumor-promoter substances. NM-203 exhibited transforming activity at a lower concentration than the other SAS. In conclusion, this study showed for the first time the transforming potential of different SAS, which act as tumor-promoter substances in the Bhas 42 model of cell transformation. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Comparison of TOF MRA, Contrast-Enhanced MRA and Subtracted CTA from CTP in Residue Evaluation of Treated Intracranial Aneurysms.

    PubMed

    Dündar, Tolga Turan; Aralaşmak, Ayşe; Özdemir, Hüseyin; Seyithanoğlu, Mehmet Hakan; Uysal, Ömer; Toprak, Hüseyin; Kitiş, Serkan; Özek, Erdinç; Alkan, Alpay

    2017-10-18

    To compare effectiveness of contrast-enhanced MRA (CE-MRA), 3D-Time-of-flight MRA (3D-TOF-MRA) and subtracted CTA from CTP (sub-CTA) in residue evaluation of intracranial aneurysms treated either with coiling or clipping. Sixteen treated aneurysms, which were evaluated with three methods within two weeks after the operation, were enrolled. The success of each imaging techniques in demonstration of residue aneurysm and nearby vessels was compared by Fisher\\'s Exact Test. The differences among three was evaluated by Cochran\\'s Q test (p ≤ 0.05). Perfusion abnormality was noted in % 81 of clipped and none of coiled patients. Vessel visualization in the vicinity of aneurysm was better in sub-CTA, followed by CE-MRA. In clipped aneurysms, sub-CTA revealed residue aneurysms in % 16,7 of the patients while 3D-TOF-MRA and CE-MRA revealed none. In coiled aneurysms, CE-MRA revealed residue aneurysms in 100 %, and TOF-MRA in 33,3 % while sub-CTA revealed none. Although dramatic differences were noted in the evaluation of residue aneurysm as well as nearby vessel visualization, no statistical significance noted due to very few patients in subcategories Conclusion: This is first study comparing the effectiveness of CE-MRA, 3D-TOF MRA and sub-CTA in residue aneurysms evaluation. Vessel visualization in the vicinity of aneurysm was better in sub-CTA in all regardless of coiling or clipping. Residue aneurysms were more commonly revealed by CE-MRA in coiled patients and more commonly and better shown by sub-CTA in clipped patients in addition of showing perfusion abnormality that's is more common in clipped patients.

  16. Clinical outcomes after magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) for pulmonary embolism evaluation.

    PubMed

    Repplinger, Michael D; Nagle, Scott K; Harringa, John B; Broman, Aimee T; Lindholm, Christopher R; François, Christopher J; Grist, Thomas M; Reeder, Scott B; Schiebler, Mark L

    2018-05-10

    To compare patient outcomes following magnetic resonance angiography (MRA) versus computed tomographic angiography (CTA) ordered for suspected pulmonary embolism (PE). In this IRB-approved, single-center, retrospective, case-control study, we reviewed the medical records of all patients evaluated for PE with MRA during a 5-year period along with age- and sex-matched controls evaluated with CTA. Only the first instance of PE evaluation during the study period was included. After application of our exclusion criteria to both study arms, the analysis included 1173 subjects. The primary endpoint was major adverse PE-related event (MAPE), which we defined as major bleeding, venous thromboembolism, or death during the 6 months following the index imaging test (MRA or CTA), obtained through medical record review. Logistic regression, chi-square test for independence, and Fisher's exact test were used with a p < 0.05 threshold. The overall 6-month MAPE rate following MRA (5.4%) was lower than following CTA (13.6%, p < 0.01). Amongst outpatients, the MAPE rate was lower for MRA (3.7%) than for CTA (8.0%, p = 0.01). Accounting for age, sex, referral source, BMI, and Wells' score, patients were less likely to suffer MAPE than those who underwent CTA, with an odds ratio of 0.44 [0.24, 0.80]. Technical success rate did not differ significantly between MRA (92.6%) and CTA (90.5%) groups (p = 0.41). Within the inherent limitations of a retrospective case-controlled analysis, we observed that the rate of MAPE was lower (more favorable) for patients following pulmonary MRA for the primary evaluation of suspected PE than following CTA.

  17. Mast cells contribute to the mucosal adjuvant effect of CTA1-DD after IgG-complex formation.

    PubMed

    Fang, Yu; Larsson, Lisa; Mattsson, Johan; Lycke, Nils; Xiang, Zou

    2010-09-01

    Mast cell activation is one of the most dramatic immune-mediated responses the body can encounter. In the worst scenario (i.e., anaphylaxis), this response is fatal. However, the importance of mast cells as initiators and effectors of both innate and adaptive immunity in healthy individuals has recently been appreciated. It was reported that mast cell activation can be used as an adjuvant to promote Ag-specific humoral immune responses upon vaccination. In this study, we have used a clinically relevant mucosal adjuvant, cholera toxin A1 subunit (CTA1)-DD, which is a fusion protein composed of CTA1, the ADP-ribosylating part of cholera toxin, and DD, two Ig-binding domains derived from Staphylococcus aureus protein A. CTA1-DD in combination with polyclonal IgG induced degranulation and production of TNF-alpha from mouse mast cells. Furthermore, CTA1-DD and polyclonal IgG complex induced mast cell degranulation in mouse skin tissue and nasal mucosa. We also found that intranasal immunization with hapten (4-hydroxy-3-nitrophenyl) acetyl (NP) coupled to chicken gammaglobulin admixed with CTA1-DD complexed with polyclonal IgG greatly enhanced serum IgG anti-NP Ab responses and stimulated higher numbers of NP-specific plasma cells in the bone marrow as compared with that observed in mice immunized with NP-chicken gammaglobulin with CTA1-DD alone. This CTA1-DD/IgG complex-mediated enhancement was mast cell dependent because it was absent in mast cell-deficient Kit(W-sh/W-sh) mice. In conclusion, our data suggest that a clinically relevant adjuvant, CTA1-DD, exerts additional augmenting effects through activation of mucosal mast cells, clearly demonstrating that mast cells could be further exploited for improving the efficacy of mucosal vaccines.

  18. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard.

    PubMed

    Joshi, Subodh B; Okabe, Teruo; Roswell, Robert O; Weissman, Gaby; Lopez, Cristian F; Lindsay, Joseph; Pichard, Augusto D; Weissman, Neil J; Waksman, Ron; Weigold, Wm Guy

    2009-10-15

    Computed tomographic angiography (CTA) is considered to have limited accuracy for quantifying exact percent diameter stenosis in coronary arteries. However, most studies evaluating CTA use quantitative coronary angiography (QCA) as the gold standard, a technique with its own limitations. We sought to determine whether CTA measurements of stenosis severity correlate better with intravascular ultrasound (IVUS) than with QCA. Luminal dimensions of 67 de novo coronary lesions were measured by CTA, IVUS, and QCA. IVUS was performed when lesion severity by angiography was equivocal. Mean percent diameter stenosis by QCA was 51 +/- 9.8% and mean IVUS minimal luminal area was 3.8 +/- 1.8 mm(2). There was a moderate correlation between CTA minimal luminal area and IVUS minimal luminal area (r(2) = 0.41, p <0.001), but no relation between CTA and QCA measurements of minimal luminal diameter (r(2) = 0.01, p = 0.57) or diameter stenosis (r(2) = 0.02, p = 0.31). There was also no relation between IVUS minimal luminal area and QCA diameter stenosis (r(2) = 0.01, p = 0.50). When lesions with moderate or severe calcification were excluded, the correlation between CTA minimal luminal area and IVUS minimal luminal area was good (r(2) = 0.68, p <0.001). In conclusion, in this cohort of patients with intermediate-grade lesions on cardiac catheterization, absolute measurements of stenosis severity on CTA correlated with IVUS but not with QCA. Our findings suggest that limitations of quantitative coronary angiography as a gold standard need to be considered in studies evaluating the accuracy of coronary CTA.

  19. Diagnostic performance of dual-energy CT stress myocardial perfusion imaging: direct comparison with cardiovascular MRI.

    PubMed

    Ko, Sung Min; Song, Meong Gun; Chee, Hyun Kun; Hwang, Hweung Kon; Feuchtner, Gudrun Maria; Min, James K

    2014-12-01

    The purpose of this study was to assess the diagnostic performance of stress perfusion dual-energy CT (DECT) and its incremental value when used with coronary CT angiography (CTA) for identifying hemodynamically significant coronary artery disease. One hundred patients with suspected or known coronary artery disease without chronic myocardial infarction detected with coronary CTA underwent stress perfusion DECT, stress cardiovascular perfusion MRI, and invasive coronary angiography (ICA). Stress perfusion DECT and cardiovascular stress perfusion MR images were used for detecting perfusion defects. Coronary CTA and ICA were evaluated in the detection of ≥50% coronary stenosis. The diagnostic performance of coronary CTA for detecting hemo-dynamically significant stenosis was assessed before and after stress perfusion DECT on a per-vessel basis with ICA and cardiovascular stress perfusion MRI as the reference standard. The performance of stress perfusion DECT compared with cardiovascular stress perfusion MRI on a per-vessel basis in the detection of perfusion defects was sensitivity, 89%; specificity, 74%; positive predictive value, 73%; negative predictive value, 90%. Per segment, these values were sensitivity, 76%; specificity, 80%; positive predictive value, 63%; and negative predictive value, 88%. Compared with ICA and cardiovascular stress perfusion MRI per vessel territory the sensitivity, specificity, positive predictive value, and negative predictive value of coronary CTA were 95%, 61%, 61%, and 95%. The values for stress perfusion DECT were 92%, 72%, 68%, and 94%. The values for coronary CTA and stress perfusion DECT were 88%, 79%, 73%, and 91%. The ROC AUC increased from 0.78 to 0.84 (p=0.02) with the use of coronary CTA and stress perfusion DECT compared with coronary CTA alone. Stress perfusion DECT plays a complementary role in enhancing the accuracy of coronary CTA for identifying hemodynamically significant coronary stenosis.

  20. CT versus MR Techniques in the Detection of Cervical Artery Dissection.

    PubMed

    Hanning, Uta; Sporns, Peter B; Schmiedel, Meilin; Ringelstein, Erich B; Heindel, Walter; Wiendl, Heinz; Niederstadt, Thomas; Dittrich, Ralf

    2017-11-01

    Spontaneous cervical artery dissection (sCAD) is an important etiology of juvenile stroke. The gold standard for the diagnosis of sCAD is convential angiography. However, magnetic resonance imaging (MRI)/MR angiography (MRA) and computed tomography (CT)/CT angiography (CTA) are frequently used alternatives. New developments such as multislice CT/CTA have enabled routine acquisition of thinner sections with rapid imaging times. The goal of this study was to compare the capability of recent developed 128-slice CT/CTA to MRI/MRA to detect radiologic features of sCAD. Retrospective review of patients with suspected sCAD (n = 188) in a database of our Stroke center (2008-2014), who underwent CT/CTA and MRI/MRA on initial clinical work-up. A control group of 26 patients was added. All Images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two modalities. Forty patients with 43 dissected arteries received both modalities (29 internal carotid arteries [ICAs] and 14 vertebral arteries [VAs]). All CADs were identified in CT/CTA and MRI/MRA. The features intimal flap, stenosis, and lumen irregularity appeared in both modalities. One high-grade stenosis was identified by CT/CTA that was expected occluded on MRI/MRA. Two MRI/MRA-confirmed pseudoaneurysms were missed by CT/CTA. None of the controls evidenced specific imaging signs for dissection. CT/CTA is a reliable and better available alternative to MRI/MRA for diagnosis of sCAD. CT/CTA should be used to complement MRI/MRA in cases where MRI/MRA suggests occlusion. Copyright © 2017 by the American Society of Neuroimaging.

  1. The role of coronary CT angiography in diagnosis of patent foramen ovale

    PubMed Central

    Kara, Kemal; Sivrioğlu, Ali Kemal; Öztürk, Ersin; İncedayı, Mehmet; Sağlam, Muzaffer; Arıbal, Serkan; Işılak, Zafer; Mutlu, Hakan

    2016-01-01

    PURPOSE We aimed to examine the incidence of patent foramen ovale (PFO) and atrial septal aneurysms (ASA) in the Turkish population using coronary computed tomography angiography (CTA); assess the feasibility of coronary CTA for PFO diagnosis by conducting a comparison with transthoracic echocardiography (TTE); and determine the diagnostic role and characteristics of the interatrial tunnel, free flap valve (FFV), and shunts. METHODS The present study was conducted retrospectively and included a sample of 782 patients. Coronary CTA results for all patients were evaluated for the following parameters: the presence of PFO, the degree of contrast jet (if present due to PFO), ASA existence, free flap valve (FFV) length, and PFO tunnel diameters (1 and 2). Coronary CTA and TTE results for PFO detection were also compared for 19 patients who underwent both procedures. RESULTS PFO was present in 118 patients (15%). In 19 patients who underwent both CTA and TTE, the shunt was present in 15 patients on TTE compared with nine patients on CTA. The sensitivity and specificity of CTA for shunt existence were 53% (8/15) and 75% (3/4), respectively. FFV was observed on CTA in 118 patients (15%). No significant relationship was observed between shunt existence and FFV length (P = 0.148), or between shunt existence and tunnel diameter-1 (P = 0.638) or diameter-2 (P = 0.058). ASAs were present in 16 patients (2%), while accompanying PFO was present in three patients (2.4%). CONCLUSION Coronary CTA constitutes a more practical and efficient alternative to TTE for PFO diagnosis. Further, it allows the clear visualization of anatomical details of the interatrial tunnel, shunts, and associated abnormalities and detects ASAs. PMID:27152642

  2. On the prospects of cross-calibrating the Cherenkov Telescope Array with an airborne calibration platform

    NASA Astrophysics Data System (ADS)

    Brown, Anthony M.

    2018-01-01

    Recent advances in unmanned aerial vehicle (UAV) technology have made UAVs an attractive possibility as an airborne calibration platform for astronomical facilities. This is especially true for arrays of telescopes spread over a large area such as the Cherenkov Telescope Array (CTA). In this paper, the feasibility of using UAVs to calibrate CTA is investigated. Assuming a UAV at 1km altitude above CTA, operating on astronomically clear nights with stratified, low atmospheric dust content, appropriate thermal protection for the calibration light source and an onboard photodiode to monitor its absolute light intensity, inter-calibration of CTA's telescopes of the same size class is found to be achievable with a 6 - 8 % uncertainty. For cross-calibration of different telescope size classes, a systematic uncertainty of 8 - 10 % is found to be achievable. Importantly, equipping the UAV with a multi-wavelength calibration light source affords us the ability to monitor the wavelength-dependent degradation of CTA telescopes' optical system, allowing us to not only maintain this 6 - 10 % uncertainty after the first few years of telescope deployment, but also to accurately account for the effect of multi-wavelength degradation on the cross-calibration of CTA by other techniques, namely with images of air showers and local muons. A UAV-based system thus provides CTA with several independent and complementary methods of cross-calibrating the optical throughput of individual telescopes. Furthermore, housing environmental sensors on the UAV system allows us to not only minimise the systematic uncertainty associated with the atmospheric transmission of the calibration signal, it also allows us to map the dust content above CTA as well as monitor the temperature, humidity and pressure profiles of the first kilometre of atmosphere above CTA with each UAV flight.

  3. Learning from Physical Analogies: A Study in Analogy and the Explanation Process

    DTIC Science & Technology

    1988-12-27

    support of the various transfer operations, the forward chaining ATRE rule system is paired with an abductive retriever. This is a backward chaining...pO) is believed.3 When a new datum is entered in the database, ATRE exhaustively runs all rules made executable by the datum’s presence in a forward ...ZR) INFLUENESST1 (CTA (AIOUN-O ?V-2)) NERTON V- (ASUM (DISSOLVE-RAT SELF))) ER ) (DSETT (SKSOLUTIO-S -12)COOL (NOTUM (LSSOU-THN-1 A CONTRATO V-P) ER

  4. The effects of area postrema lesions and selective vagotomy on motion-induced conditioned taste aversion

    NASA Technical Reports Server (NTRS)

    Fox, Robert A.; Sutton, R. L.; Mckenna, Susan

    1991-01-01

    Conditioned taste aversion (CTA) is one of several behaviors which was suggested as a putative measure of motion sickness in rats. A review is made of studies which used surgical disruption of area postrema or the vagus nerve to investigate whether CTA and vomiting induced by motion may depend on common neural pathways or structures. When the chemoreceptive function of the area postrema (AP) is destroyed by complete ablation, rats develop CTA and cats and monkeys develop CTA and vomit. Thus the AP is not crucially involved in either CTA or vomiting induced by motion. However, after complete denervation of the stomach or after labyrinthectomy rats do not develop CTA when motion is used as the unconditioned stimulus. Studies of brainstem projections of the vagus nerve, the area postrema, the periaqueductal grey, and the vestibular system are used as the basis for speculation about regions which could mediate both motion-induced vomiting and behavioral food aversion.

  5. Comparison of biofouling mechanisms between cellulose triacetate (CTA) and thin-film composite (TFC) polyamide forward osmosis membranes in osmotic membrane bioreactors.

    PubMed

    Wang, Xinhua; Zhao, Yanxiao; Yuan, Bo; Wang, Zhiwei; Li, Xiufen; Ren, Yueping

    2016-02-01

    There are two types of popular forward osmosis (FO) membrane materials applied for researches on FO process, cellulose triacetate (CTA) and thin film composite (TFC) polyamide. However, performance and fouling mechanisms of commercial TFC FO membrane in osmotic membrane bioreactors (OMBRs) are still unknown. In current study, its biofouling behaviors in OMBRs were investigated and further compared to the CTA FO membrane. The results indicated that β-D-glucopyranose polysaccharides and microorganisms accounted for approximately 77% of total biovolume on the CTA FO membrane while β-D-glucopyranose polysaccharides (biovolume ratio of 81.1%) were the only dominant biofoulants on the TFC FO membrane. The analyses on the biofouling structure implied that a tighter biofouling layer with a larger biovolume was formed on the CTA FO membrane. The differences in biofouling behaviors including biofoulants composition and biofouling structure between CTA and TFC FO membranes were attributed to different membrane surface properties. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. CT Angiography and Presentation NIH stroke Scale in Predicting TIA in Patients Presenting with Acute Stroke Symptoms.

    PubMed

    Karaman, Bedriye; Selph, James; Burdine, Joselyn; Graham, Cole Blease; Sen, Souvik

    2013-11-08

    Patient candidacy for acute stroke intervention, is currently assessed using brain computed tomography angiography (CTA) evidence of significant stenosis/occlusion (SSO) with a high National Institutes of Health Stroke Scale (NIHSS) (>6). This study examined the association between CTA without significant stenosis/occlusion (NSSO) and lower NIHSS (≤ 6) with transient ischemic attack (TIA) and other good clinical outcomes at discharge. Patients presenting <8 hours from stroke symptom onset, had an NIHSS assessment and brain CTA performed at presentation. Good clinical outcomes were defined as: discharge diagnosis of TIA, modified Rankin Score [mRS] ≤ 1, and home as the discharge disposition. Eighty-five patients received both an NIHSS at presentation and a CTA at 4.2 ± 2.2 hours from stroke symptom onset. Patients with NSSO on CTA as well as those with NIHSS≤6 had better outcomes at discharge (p<0.001). NIHSS ≤ 6 were more likely than NSSO (p=0.01) to have a discharge diagnosis of TIA (p<0.001). NSSO on CTA and NIHSS ≤ 6 also correlated with fewer deaths (p<0.001). Multivariable analyses showed NSSO on CTA (Adjusted OR: 5.8 95% CI: 1.2-27.0, p=0.03) independently predicted the discharge diagnosis of TIA. Addition of NIHSS ≤ 6 to NSSO on CTA proved to be a stronger independent predictor of TIA (Adjusted OR 18.7 95% CI: 3.5-98.9, p=0.001).

  7. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding.

    PubMed

    Wildgruber, Moritz; Wrede, Christian E; Zorger, Niels; Müller-Wille, René; Hamer, Okka W; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-03-01

    The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%-99%) and 29% (7 of 24 patients; 95% CI 12%-49%) of patients, respectively (p<0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%-63%) and 21% (5 of 24; 95% CI 7%-42%) of patients, respectively (p=0.06). Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB. Copyright © 2016. Published by Elsevier B.V.

  8. Contact topical anesthesia versus general anaesthesia in strabismus surgery.

    PubMed

    Vallés-Torres, J; Garcia-Martin, E; Fernández-Tirado, F J; Gil-Arribas, L M; Pablo, L E; Peña-Calvo, P

    2016-03-01

    To evaluate the anesthetic block provided by contact topical anesthesia (CTA) in strabismus surgery in adult patients. To analyze postoperative pain and surgical outcome obtained by CTA compared with general anesthesia (GA). Prospective longitudinal cohort study of adult patients undergoing strabismus surgery by CTA or GA. The intensity of pain perceived by patients during the course of surgery and in the postoperative period was measured using Numerical Pain Scale. The success of the surgical outcome, considered as a residual ocular deviation<10 prism diopters, was evaluated. Twenty-three patients were operated using CTA and 26 using AG. During the course of surgery, pain intensity experienced by patients in ATC group was 3.17±2.44. There were no differences between CTA group and AG group in the intensity of pain in the immediate postoperative period (2.13±2.39 vs. 2.77±2.18, respectively; P=.510) and during the first postoperative day (3.22±2.84 vs. 3.17±2.73; P=.923). Surgical success was significantly higher in the CTA group than in the GA group (78.3 vs. 73.1%; P=.019). CTA provides adequate sensory block to perform strabismus surgery. The control of postoperative pain is similar to that obtained with AG. Conservation of ocular motility providing CTA enables better surgical outcome. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  9. Adjuvant Activity of the Catalytic A1 Domain of Cholera Toxin for Retroviral Antigens Delivered by GeneGun▿

    PubMed Central

    Bagley, Kenneth C.; Lewis, George K.; Fouts, Timothy R.

    2011-01-01

    Most DNA-encoded adjuvants enhance immune responses to DNA vaccines in small animals but are less effective in primates. Here, we characterize the adjuvant activity of the catalytic A1 domain of cholera toxin (CTA1) for human immunodeficiency virus (HIV) and simian immunodeficiency virus (SIV) antigens in mice and macaques delivered by GeneGun. The inclusion of CTA1 with SIVmac239 Gag dramatically enhanced anti-Gag antibody responses in mice. The adjuvant effects of CTA1 for the secreted antigen HIV gp120 were much less pronounced than those for Gag, as the responses to gp120 were high in the absence of an adjuvant. CTA1 was a stronger adjuvant for Gag than was granulocyte-macrophage colony-stimulating factor (GM-CSF), and it also displayed a wider dose range than GM-CSF in mice. In macaques, CTA1 modestly enhanced the antibody responses to SIV Gag but potently primed for a recombinant Gag protein boost. The results of this study show that CTA1 is a potent adjuvant for SIV Gag when delivered by GeneGun in mice and that CTA1 provides a potent GeneGun-mediated DNA prime for a heterologous protein boost in macaques. PMID:21508173

  10. Adjuvant activity of the catalytic A1 domain of cholera toxin for retroviral antigens delivered by GeneGun.

    PubMed

    Bagley, Kenneth C; Lewis, George K; Fouts, Timothy R

    2011-06-01

    Most DNA-encoded adjuvants enhance immune responses to DNA vaccines in small animals but are less effective in primates. Here, we characterize the adjuvant activity of the catalytic A1 domain of cholera toxin (CTA1) for human immunodeficiency virus (HIV) and simian immunodeficiency virus (SIV) antigens in mice and macaques delivered by GeneGun. The inclusion of CTA1 with SIVmac239 Gag dramatically enhanced anti-Gag antibody responses in mice. The adjuvant effects of CTA1 for the secreted antigen HIV gp120 were much less pronounced than those for Gag, as the responses to gp120 were high in the absence of an adjuvant. CTA1 was a stronger adjuvant for Gag than was granulocyte-macrophage colony-stimulating factor (GM-CSF), and it also displayed a wider dose range than GM-CSF in mice. In macaques, CTA1 modestly enhanced the antibody responses to SIV Gag but potently primed for a recombinant Gag protein boost. The results of this study show that CTA1 is a potent adjuvant for SIV Gag when delivered by GeneGun in mice and that CTA1 provides a potent GeneGun-mediated DNA prime for a heterologous protein boost in macaques.

  11. Effects of heavy particle irradiation and diet on amphetamine- and lithium chloride-induced taste avoidance learning in rats

    NASA Technical Reports Server (NTRS)

    Rabin, Bernard M.; Shukitt-Hale, Barbara; Szprengiel, Aleksandra; Joseph, James A.

    2002-01-01

    Rats were maintained on diets containing either 2% blueberry or strawberry extract or a control diet for 8 weeks prior to being exposed to 1.5 Gy of 56Fe particles in the Alternating Gradient Synchrotron at Brookhaven National Laboratory. Three days following irradiation, the rats were tested for the effects of irradiation on the acquisition of an amphetamine- or lithium chloride-induced (LiCl) conditioned taste avoidance (CTA). The rats maintained on the control diet failed to show the acquisition of a CTA following injection of amphetamine. In contrast, the rats maintained on antioxidant diets (strawberry or blueberry extract) continued to show the development of an amphetamine-induced CTA following exposure to 56Fe particles. Neither irradiation nor diet had an effect on the acquisition of a LiCl-induced CTA. The results are interpreted as indicating that oxidative stress following exposure to 56Fe particles may be responsible for the disruption of the dopamine-mediated amphetamine-induced CTA in rats fed control diets; and that a reduction in oxidative stress produced by the antioxidant diets functions to reinstate the dopamine-mediated CTA. The failure of either irradiation or diet to influence LiCl-induced responding suggests that oxidative stress may not be involved in CTA learning following injection of LiCl.

  12. The use of cognitive task analysis to reveal the instructional limitations of experts in the teaching of procedural skills.

    PubMed

    Sullivan, Maura E; Yates, Kenneth A; Inaba, Kenji; Lam, Lydia; Clark, Richard E

    2014-05-01

    Because of the automated nature of knowledge, experts tend to omit information when describing a task. A potential solution is cognitive task analysis (CTA). The authors investigated the percentage of knowledge experts omitted when teaching a cricothyrotomy to determine the percentage of additional knowledge gained during a CTA interview. Three experts were videotaped teaching a cricothyrotomy in 2010 at the University of Southern California. After transcription, they participated in CTA interviews for the same procedure. Three additional surgeons were recruited to perform a CTA for the procedure, and a "gold standard" task list was created. Transcriptions from the teaching sessions were compared with the task list to identify omitted steps (both "what" and "how" to do). Transcripts from the CTA interviews were compared against the task list to determine the percentage of knowledge articulated by each expert during the initial "free recall" (unprompted) phase of the CTA interview versus the amount of knowledge gained by using CTA elicitation techniques (prompted). Experts omitted an average of 71% (10/14) of clinical knowledge steps, 51% (14/27) of action steps, and 73% (3.6/5) of decision steps. For action steps, experts described "how to do it" only 13% (3.6/27) of the time. The average number of steps that were described increased from 44% (20/46) when unprompted to 66% (31/46) when prompted. This study supports previous research that experts unintentionally omit knowledge when describing a procedure. CTA is a useful method to extract automated knowledge and augment expert knowledge recall during teaching.

  13. Effects of treadmill exercise on the LiCl-induced conditioned taste aversion in rats.

    PubMed

    Tsuboi, Hisanori; Hirai, Yoshiyuki; Maezawa, Hitoshi; Notani, Kenji; Inoue, Nobuo; Funahashi, Makoto

    2015-01-01

    Studies have shown that exercise can enhance learning and memory. Conditioned taste aversion (CTA) is an avoidance behavior induced by associative memory of the taste sensation for something pleasant or neutral with a negative visceral reaction caused by the coincident action of a toxic substance that is tasteless or administered systemically. We sought to measure the effects of treadmill exercise on CTA in rats by investigating the effects of exercise on acquisition, extinction and spontaneous recovery of CTA. We made two groups of rats: an exercise group that ran on a treadmill, and a control group that did not have structured exercise periods. To condition rats to disfavor a sweet taste, consumption of a 0.1% saccharin solution in place of drinking water was paired with 0.15M LiCl (2% body weight, i.p.) to induce visceral discomfort. We measured changes of saccharin consumption during acquisition and extinction of CTA. The exercise and no-exercise groups both acquired CTA to similar levels and showed maximum extinction of CTA around 6 days after acquisition. This result indicates that exercise affects neither acquisition nor extinction of CTA. However, in testing for preservation of CTA after much longer extinction periods that included exercise or not during the intervening period, exercising animals showed a significantly lower saccharin intake, irrespective of having exercised or not during the conditioning phase of the trial. This result suggests that exercise may help to preserve aversive memory (taste aversion in this example) as evidence by the significant spontaneous recovery of aversion in exercising animals. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Diagnosing Internal Herniation After Roux-en-Y Gastric Bypass Surgery: Literature Overview, Cadaver Study and the Added Value of 3D CT Angiography.

    PubMed

    Klop, Cornelis; Deden, Laura N; Aarts, Edo O; Janssen, Ignace M C; Pijl, Milan E J; van den Ende, Anneline; Witteman, Bart P L; de Jong, Gabie M; Aufenacker, Theo J; Slump, Cornelis H; Berends, Frits J

    2018-02-05

    The purposes of the study are to outline the complexity of diagnosing internal herniation after Roux-en-Y gastric bypass (RYGB) surgery and to investigate the added value of computed tomography angiography (CTA) for diagnosing internal herniation. A cadaver study was performed to investigate the manifestations of internal hernias and mesenteric vascularization. Furthermore, a prospective, ethics approved study with retrospective interpretation was conducted. Ten patients, clinically suspected for internal herniation, were prospectively included. After informed consent was obtained, these subjects underwent abdominal CT examination, including additional arterial phase CTA. All subjects underwent diagnostic laparoscopy for suspected internal herniation. The CTA was used to create a 3D reconstruction of the mesenteric arteries and surgical staples (3D CTA). The 3D CTA was interpreted, taking into account the presence and type of internal hernia that was found upon laparoscopy. Cadaveric analysis demonstrated the complexity of internal herniation. It also confirmed the expected changes in vascular structure and surgical staple arrangement in the presence of internal herniation. 3D CTA studies of the subjects with active internal hernias demonstrated remarkable differences when compared to control 3D CTA studies. The blood supply of herniated intestinal limbs in particular showed abnormal trajectories. Additionally, enteroenterostomy staple lines had migrated or altered orientation. 3D CTA is a promising technique for diagnosing active internal hernias. Our findings suggest that for diagnosing internal hernias, focus should probably shift from routine abdominal CT examination towards the 3D assessment of the mesenteric vasculature and surgical staples.

  15. Design concepts for the Cherenkov Telescope Array CTA: an advanced facility for ground-based high-energy gamma-ray astronomy

    NASA Astrophysics Data System (ADS)

    Actis, M.; Agnetta, G.; Aharonian, F.; Akhperjanian, A.; Aleksić, J.; Aliu, E.; Allan, D.; Allekotte, I.; Antico, F.; Antonelli, L. A.; Antoranz, P.; Aravantinos, A.; Arlen, T.; Arnaldi, H.; Artmann, S.; Asano, K.; Asorey, H.; Bähr, J.; Bais, A.; Baixeras, C.; Bajtlik, S.; Balis, D.; Bamba, A.; Barbier, C.; Barceló, M.; Barnacka, A.; Barnstedt, J.; Barres de Almeida, U.; Barrio, J. A.; Basso, S.; Bastieri, D.; Bauer, C.; Becerra, J.; Becherini, Y.; Bechtol, K.; Becker, J.; Beckmann, V.; Bednarek, W.; Behera, B.; Beilicke, M.; Belluso, M.; Benallou, M.; Benbow, W.; Berdugo, J.; Berger, K.; Bernardino, T.; Bernlöhr, K.; Biland, A.; Billotta, S.; Bird, T.; Birsin, E.; Bissaldi, E.; Blake, S.; Blanch, O.; Bobkov, A. A.; Bogacz, L.; Bogdan, M.; Boisson, C.; Boix, J.; Bolmont, J.; Bonanno, G.; Bonardi, A.; Bonev, T.; Borkowski, J.; Botner, O.; Bottani, A.; Bourgeat, M.; Boutonnet, C.; Bouvier, A.; Brau-Nogué, S.; Braun, I.; Bretz, T.; Briggs, M. S.; Brun, P.; Brunetti, L.; Buckley, J. H.; Bugaev, V.; Bühler, R.; Bulik, T.; Busetto, G.; Buson, S.; Byrum, K.; Cailles, M.; Cameron, R.; Canestrari, R.; Cantu, S.; Carmona, E.; Carosi, A.; Carr, J.; Carton, P. H.; Casiraghi, M.; Castarede, H.; Catalano, O.; Cavazzani, S.; Cazaux, S.; Cerruti, B.; Cerruti, M.; Chadwick, P. M.; Chiang, J.; Chikawa, M.; Cieślar, M.; Ciesielska, M.; Cillis, A.; Clerc, C.; Colin, P.; Colomé, J.; Compin, M.; Conconi, P.; Connaughton, V.; Conrad, J.; Contreras, J. L.; Coppi, P.; Corlier, M.; Corona, P.; Corpace, O.; Corti, D.; Cortina, J.; Costantini, H.; Cotter, G.; Courty, B.; Couturier, S.; Covino, S.; Croston, J.; Cusumano, G.; Daniel, M. K.; Dazzi, F.; de Angelis, A.; de Cea Del Pozo, E.; de Gouveia Dal Pino, E. M.; de Jager, O.; de La Calle Pérez, I.; de La Vega, G.; de Lotto, B.; de Naurois, M.; de Oña Wilhelmi, E.; de Souza, V.; Decerprit, B.; Deil, C.; Delagnes, E.; Deleglise, G.; Delgado, C.; Dettlaff, T.; di Paolo, A.; di Pierro, F.; Díaz, C.; Dick, J.; Dickinson, H.; Digel, S. W.; Dimitrov, D.; Disset, G.; Djannati-Ataï, A.; Doert, M.; Domainko, W.; Dorner, D.; Doro, M.; Dournaux, J.-L.; Dravins, D.; Drury, L.; Dubois, F.; Dubois, R.; Dubus, G.; Dufour, C.; Durand, D.; Dyks, J.; Dyrda, M.; Edy, E.; Egberts, K.; Eleftheriadis, C.; Elles, S.; Emmanoulopoulos, D.; Enomoto, R.; Ernenwein, J.-P.; Errando, M.; Etchegoyen, A.; Falcone, A. D.; Farakos, K.; Farnier, C.; Federici, S.; Feinstein, F.; Ferenc, D.; Fillin-Martino, E.; Fink, D.; Finley, C.; Finley, J. P.; Firpo, R.; Florin, D.; Föhr, C.; Fokitis, E.; Font, Ll.; Fontaine, G.; Fontana, A.; Förster, A.; Fortson, L.; Fouque, N.; Fransson, C.; Fraser, G. W.; Fresnillo, L.; Fruck, C.; Fujita, Y.; Fukazawa, Y.; Funk, S.; Gäbele, W.; Gabici, S.; Gadola, A.; Galante, N.; Gallant, Y.; García, B.; García López, R. J.; Garrido, D.; Garrido, L.; Gascón, D.; Gasq, C.; Gaug, M.; Gaweda, J.; Geffroy, N.; Ghag, C.; Ghedina, A.; Ghigo, M.; Gianakaki, E.; Giarrusso, S.; Giavitto, G.; Giebels, B.; Giro, E.; Giubilato, P.; Glanzman, T.; Glicenstein, J.-F.; Gochna, M.; Golev, V.; Gómez Berisso, M.; González, A.; González, F.; Grañena, F.; Graciani, R.; Granot, J.; Gredig, R.; Green, A.; Greenshaw, T.; Grimm, O.; Grube, J.; Grudzińska, M.; Grygorczuk, J.; Guarino, V.; Guglielmi, L.; Guilloux, F.; Gunji, S.; Gyuk, G.; Hadasch, D.; Haefner, D.; Hagiwara, R.; Hahn, J.; Hallgren, A.; Hara, S.; Hardcastle, M. J.; Hassan, T.; Haubold, T.; Hauser, M.; Hayashida, M.; Heller, R.; Henri, G.; Hermann, G.; Herrero, A.; Hinton, J. A.; Hoffmann, D.; Hofmann, W.; Hofverberg, P.; Horns, D.; Hrupec, D.; Huan, H.; Huber, B.; Huet, J.-M.; Hughes, G.; Hultquist, K.; Humensky, T. B.; Huppert, J.-F.; Ibarra, A.; Illa, J. M.; Ingjald, J.; Inoue, Y.; Inoue, S.; Ioka, K.; Jablonski, C.; Jacholkowska, A.; Janiak, M.; Jean, P.; Jensen, H.; Jogler, T.; Jung, I.; Kaaret, P.; Kabuki, S.; Kakuwa, J.; Kalkuhl, C.; Kankanyan, R.; Kapala, M.; Karastergiou, A.; Karczewski, M.; Karkar, S.; Karlsson, N.; Kasperek, J.; Katagiri, H.; Katarzyński, K.; Kawanaka, N.; Kȩdziora, B.; Kendziorra, E.; Khélifi, B.; Kieda, D.; Kifune, T.; Kihm, T.; Klepser, S.; Kluźniak, W.; Knapp, J.; Knappy, A. R.; Kneiske, T.; Knödlseder, J.; Köck, F.; Kodani, K.; Kohri, K.; Kokkotas, K.; Komin, N.; Konopelko, A.; Kosack, K.; Kossakowski, R.; Kostka, P.; Kotuła, J.; Kowal, G.; Kozioł, J.; Krähenbühl, T.; Krause, J.; Krawczynski, H.; Krennrich, F.; Kretzschmann, A.; Kubo, H.; Kudryavtsev, V. A.; Kushida, J.; La Barbera, N.; La Parola, V.; La Rosa, G.; López, A.; Lamanna, G.; Laporte, P.; Lavalley, C.; Le Flour, T.; Le Padellec, A.; Lenain, J.-P.; Lessio, L.; Lieunard, B.; Lindfors, E.; Liolios, A.; Lohse, T.; Lombardi, S.; Lopatin, A.; Lorenz, E.; Lubiński, P.; Luz, O.; Lyard, E.; Maccarone, M. C.; Maccarone, T.; Maier, G.; Majumdar, P.; Maltezos, S.; Małkiewicz, P.; Mañá, C.; Manalaysay, A.; Maneva, G.; Mangano, A.; Manigot, P.; Marín, J.; Mariotti, M.; Markoff, S.; Martínez, G.; Martínez, M.; Mastichiadis, A.; Matsumoto, H.; Mattiazzo, S.; Mazin, D.; McComb, T. J. L.; McCubbin, N.; McHardy, I.; Medina, C.; Melkumyan, D.; Mendes, A.; Mertsch, P.; Meucci, M.; Michałowski, J.; Micolon, P.; Mineo, T.; Mirabal, N.; Mirabel, F.; Miranda, J. M.; Mirzoyan, R.; Mizuno, T.; Moal, B.; Moderski, R.; Molinari, E.; Monteiro, I.; Moralejo, A.; Morello, C.; Mori, K.; Motta, G.; Mottez, F.; Moulin, E.; Mukherjee, R.; Munar, P.; Muraishi, H.; Murase, K.; Murphy, A. Stj.; Nagataki, S.; Naito, T.; Nakamori, T.; Nakayama, K.; Naumann, C.; Naumann, D.; Nayman, P.; Nedbal, D.; Niedźwiecki, A.; Niemiec, J.; Nikolaidis, A.; Nishijima, K.; Nolan, S. J.; Nowak, N.; O'Brien, P. T.; Ochoa, I.; Ohira, Y.; Ohishi, M.; Ohka, H.; Okumura, A.; Olivetto, C.; Ong, R. A.; Orito, R.; Orr, M.; Osborne, J. P.; Ostrowski, M.; Otero, L.; Otte, A. N.; Ovcharov, E.; Oya, I.; Oziȩbło, A.; Paiano, S.; Pallota, J.; Panazol, J. L.; Paneque, D.; Panter, M.; Paoletti, R.; Papyan, G.; Paredes, J. M.; Pareschi, G.; Parsons, R. D.; Paz Arribas, M.; Pedaletti, G.; Pepato, A.; Persic, M.; Petrucci, P. O.; Peyaud, B.; Piechocki, W.; Pita, S.; Pivato, G.; Płatos, Ł.; Platzer, R.; Pogosyan, L.; Pohl, M.; Pojmański, G.; Ponz, J. D.; Potter, W.; Prandini, E.; Preece, R.; Prokoph, H.; Pühlhofer, G.; Punch, M.; Quel, E.; Quirrenbach, A.; Rajda, P.; Rando, R.; Rataj, M.; Raue, M.; Reimann, C.; Reimann, O.; Reimer, A.; Reimer, O.; Renaud, M.; Renner, S.; Reymond, J.-M.; Rhode, W.; Ribó, M.; Ribordy, M.; Rico, J.; Rieger, F.; Ringegni, P.; Ripken, J.; Ristori, P.; Rivoire, S.; Rob, L.; Rodriguez, S.; Roeser, U.; Romano, P.; Romero, G. E.; Rosier-Lees, S.; Rovero, A. C.; Roy, F.; Royer, S.; Rudak, B.; Rulten, C. B.; Ruppel, J.; Russo, F.; Ryde, F.; Sacco, B.; Saggion, A.; Sahakian, V.; Saito, K.; Saito, T.; Sakaki, N.; Salazar, E.; Salini, A.; Sánchez, F.; Sánchez Conde, M. Á.; Santangelo, A.; Santos, E. M.; Sanuy, A.; Sapozhnikov, L.; Sarkar, S.; Scalzotto, V.; Scapin, V.; Scarcioffolo, M.; Schanz, T.; Schlenstedt, S.; Schlickeiser, R.; Schmidt, T.; Schmoll, J.; Schroedter, M.; Schultz, C.; Schultze, J.; Schulz, A.; Schwanke, U.; Schwarzburg, S.; Schweizer, T.; Seiradakis, J.; Selmane, S.; Seweryn, K.; Shayduk, M.; Shellard, R. C.; Shibata, T.; Sikora, M.; Silk, J.; Sillanpää, A.; Sitarek, J.; Skole, C.; Smith, N.; Sobczyńska, D.; Sofo Haro, M.; Sol, H.; Spanier, F.; Spiga, D.; Spyrou, S.; Stamatescu, V.; Stamerra, A.; Starling, R. L. C.; Stawarz, Ł.; Steenkamp, R.; Stegmann, C.; Steiner, S.; Stergioulas, N.; Sternberger, R.; Stinzing, F.; Stodulski, M.; Straumann, U.; Suárez, A.; Suchenek, M.; Sugawara, R.; Sulanke, K. H.; Sun, S.; Supanitsky, A. D.; Sutcliffe, P.; Szanecki, M.; Szepieniec, T.; Szostek, A.; Szymkowiak, A.; Tagliaferri, G.; Tajima, H.; Takahashi, H.; Takahashi, K.; Takalo, L.; Takami, H.; Talbot, R. G.; Tam, P. H.; Tanaka, M.; Tanimori, T.; Tavani, M.; Tavernet, J.-P.; Tchernin, C.; Tejedor, L. A.; Telezhinsky, I.; Temnikov, P.; Tenzer, C.; Terada, Y.; Terrier, R.; Teshima, M.; Testa, V.; Tibaldo, L.; Tibolla, O.; Tluczykont, M.; Todero Peixoto, C. J.; Tokanai, F.; Tokarz, M.; Toma, K.; Torres, D. F.; Tosti, G.; Totani, T.; Toussenel, F.; Vallania, P.; Vallejo, G.; van der Walt, J.; van Eldik, C.; Vandenbroucke, J.; Vankov, H.; Vasileiadis, G.; Vassiliev, V. V.; Vegas, I.; Venter, L.; Vercellone, S.; Veyssiere, C.; Vialle, J. P.; Videla, M.; Vincent, P.; Vink, J.; Vlahakis, N.; Vlahos, L.; Vogler, P.; Vollhardt, A.; Volpe, F.; von Gunten, H. P.; Vorobiov, S.; Wagner, S.; Wagner, R. M.; Wagner, B.; Wakely, S. P.; Walter, P.; Walter, R.; Warwick, R.; Wawer, P.; Wawrzaszek, R.; Webb, N.; Wegner, P.; Weinstein, A.; Weitzel, Q.; Welsing, R.; Wetteskind, H.; White, R.; Wierzcholska, A.; Wilkinson, M. I.; Williams, D. A.; Winde, M.; Wischnewski, R.; Wiśniewski, Ł.; Wolczko, A.; Wood, M.; Xiong, Q.; Yamamoto, T.; Yamaoka, K.; Yamazaki, R.; Yanagita, S.; Yoffo, B.; Yonetani, M.; Yoshida, A.; Yoshida, T.; Yoshikoshi, T.; Zabalza, V.; Zagdański, A.; Zajczyk, A.; Zdziarski, A.; Zech, A.; Ziȩtara, K.; Ziółkowski, P.; Zitelli, V.; Zychowski, P.

    2011-12-01

    Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.

  16. Cost-effectiveness of digital subtraction angiography in the setting of computed tomographic angiography negative subarachnoid hemorrhage.

    PubMed

    Jethwa, Pinakin R; Punia, Vineet; Patel, Tapan D; Duffis, E Jesus; Gandhi, Chirag D; Prestigiacomo, Charles J

    2013-04-01

    Recent studies have documented the high sensitivity of computed tomography angiography (CTA) in detecting a ruptured aneurysm in the presence of acute subarachnoid hemorrhage (SAH). The practice of digital subtraction angiography (DSA) when CTA does not reveal an aneurysm has thus been called into question. We examined this dilemma from a cost-effectiveness perspective by using current decision analysis techniques. A decision tree was created with the use of TreeAge Pro Suite 2012; in 1 arm, a CTA-negative SAH was followed up with DSA; in the other arm, patients were observed without further imaging. Based on literature review, costs and utilities were assigned to each potential outcome. Base-case and sensitivity analyses were performed to determine the cost-effectiveness of each strategy. A Monte Carlo simulation was then conducted by sampling each variable over a plausible distribution to evaluate the robustness of the model. With the use of a negative predictive value of 95.7% for CTA, observation was found to be the most cost-effective strategy ($6737/Quality Adjusted Life Year [QALY] vs $8460/QALY) in the base-case analysis. One-way sensitivity analysis demonstrated that DSA became the more cost-effective option if the negative predictive value of CTA fell below 93.72%. The Monte Carlo simulation produced an incremental cost-effectiveness ratio of $83 083/QALY. At the conventional willingness-to-pay threshold of $50 000/QALY, observation was the more cost-effective strategy in 83.6% of simulations. The decision to perform a DSA in CTA-negative SAH depends strongly on the sensitivity of CTA, and therefore must be evaluated at each center treating these types of patients. Given the high sensitivity of CTA reported in the current literature, performing DSA on all patients with CTA negative SAH may not be cost-effective at every institution.

  17. A safe and effective management strategy for blunt cerebrovascular injury: Avoiding unnecessary anticoagulation and eliminating stroke.

    PubMed

    Shahan, Charles P; Magnotti, Louis J; Stickley, Shaun M; Weinberg, Jordan A; Hendrick, Leah E; Uhlmann, Rebecca A; Schroeppel, Thomas J; Hoit, Daniel A; Croce, Martin A; Fabian, Timothy C

    2016-06-01

    Few injuries have produced as much debate with respect to management as have blunt cerebrovascular injuries (BCVIs). Recent work (American Association for the Surgery of Trauma 2013) from our institution suggested that 64-channel multidetector computed tomographic angiography (CTA) could be the primary screening tool for BCVI. Consequently, our screening algorithm changed from digital subtraction angiography (DSA) to CTA, with DSA reserved for definitive diagnosis of BCVI following CTA-positive study results or unexplained neurologic findings. The current study was performed to evaluate outcomes, including the potential for missed clinically significant BCVI, since this new management algorithm was adopted. Patients who underwent DSA (positive CTA finding or unexplained neurologic finding) over an 18-month period subsequent to the previous study were identified. Screening and confirmatory test results, complications, and BCVI-related strokes were reviewed and compared. A total of 228 patients underwent DSA: 64% were male, with mean age and Injury Severity Score (ISS) of 43 years and 22, respectively. A total of 189 patients (83%) had a positive screening CTA result. Of these, DSA confirmed injury in 104 patients (55%); the remaining 85 patients (45%) (false-positive results) were found to have no injury on DSA. Five patients (4.8%) experienced BCVI-related strokes, unchanged from the previous study (3.9%, p = 0.756); two were symptomatic at trauma center presentation, and three occurred while receiving appropriate therapy. No patient with a negative screening CTA result experienced a stroke. This management scheme using 64-channel CTA for screening coupled with DSA for definitive diagnosis was proven to be safe and effective in identifying clinically significant BCVIs and maintaining a low stroke rate. Definitive diagnosis by DSA led to avoidance of potentially harmful anticoagulation in 45% of CTA-positive patients (false-positive results). No strokes resulted from injuries missed by CTA. Diagnostic study, level III.

  18. The High-Level Interface Definitions in the ASTRI/CTA Mini Array Software System (MASS)

    NASA Astrophysics Data System (ADS)

    Conforti, V.; Tosti, G.; Schwarz, J.; Bruno, P.; Cefal‘A, M.; Paola, A. D.; Gianotti, F.; Grillo, A.; Russo, F.; Tanci, C.; Testa, V.; Antonelli, L. A.; Canestrari, R.; Catalano, O.; Fiorini, M.; Gallozzi, S.; Giro, E.; Palombara, N. L.; Leto, G.; Maccarone, M. C.; Pareschi, G.; Stringhetti, L.; Trifoglio, M.; Vercellone, S.; Astri Collaboration; Cta Consortium

    2015-09-01

    ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is a Flagship Project funded by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. Within this framework, INAF is currently developing an end-to-end prototype, named ASTRI SST-2M, of a Small Size Dual-Mirror Telescope for the Cherenkov Telescope Array, CTA. A second goal of the project is the realization of the ASTRI/CTA mini-array, which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The ASTRI Mini Array Software System (MASS) is designed to support the ASTRI/CTA mini-array operations. MASS is being built on top of the ALMA Common Software (ACS) framework, which provides support for the implementation of distributed data acquisition and control systems, and functionality for log and alarm management, message driven communication and hardware devices management. The first version of the MASS system, which will comply with the CTA requirements and guidelines, will be tested on the ASTRI SST-2M prototype. In this contribution we present the interface definitions of the MASS high level components in charge of the ASTRI SST-2M observation scheduling, telescope control and monitoring, and data taking. Particular emphasis is given to their potential reuse for the ASTRI/CTA mini-array.

  19. Carotid artery stents on CT angiography: in vitro comparison of different stent designs and sizes using 16-, 64- and 320-row CT scanners.

    PubMed

    Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan

    2014-10-01

    CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. CONSEQUENCES OF REPEATED ETHANOL EXPOSURE DURING EARLY OR LATE ADOLESCENCE ON CONDITIONED TASTE AVERSIONS IN RATS

    PubMed Central

    Saalfield, Jessica; Spear, Linda

    2015-01-01

    Alcohol use is prevalent during adolescence, yet little is known about possible long-lasting consequences.. Recent evidence suggests that adolescents are less sensitive than adults to ethanol’s aversive effects, an insensitivity that may be retained into adulthood after repeated adolescent ethanol exposure. This study assessed whether intermittent ethanol exposure during early or late adolescence (early-AIE or late-AIE, respectively) would affect ethanol conditioned taste aversions 2 days (CTA1) and >3 weeks (CTA2) post-exposure using supersaccharin and saline as conditioning stimuli (CS), respectively. Pair-housed male Sprague-Dawley rats received 4 g/kg i.g. ethanol (25%) or water every 48 hours from postnatal day (P) 25–45 (early AIE) or P45–65 (late AIE), or were left non-manipulated (NM). During conditioning, 30 min home cage access to the CS was followed by 0, 1, 1.5, 2 or 2.5 g/kg ethanol i.p., with testing 2 days later. Attenuated CTA relative to controls was seen among early and late AIE animals at both CTA1 and CTA2, an effect particularly pronounced at CTA1 after late AIE. Thus, adolescent exposure to ethanol was found to induce an insensitivity to ethanol CTA seen soon after exposure and lasting into adulthood, and evident with ethanol exposures not only early but also later in adolescence. PMID:25698309

  1. Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

    PubMed

    Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui

    2014-01-01

    The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.

  2. 64-MDCT angiography of blunt vascular injuries of the neck.

    PubMed

    Chokshi, Falgun H; Munera, Felipe; Rivas, Luis A; Henry, Robert P; Quencer, Robert M

    2011-03-01

    CT angiography (CTA) using 64-MDCT enables timely evaluation of injuries associated with blunt neck trauma. The purpose of this article is to familiarize the reader with the most frequent CTA signs of blunt vascular injury. CTA is a valuable tool to detect blunt vascular injuries, especially using its multiplanar and 3D reconstruction capabilities.

  3. Cognitive Task Analysis for Instruction in Single-Injection Ultrasound Guided-Regional Anesthesia

    ERIC Educational Resources Information Center

    Gucev, Gligor V.

    2012-01-01

    Cognitive task analysis (CTA) is methodology for eliciting knowledge from subject matter experts. CTA has been used to capture the cognitive processes, decision-making, and judgments that underlie expert behaviors. A review of the literature revealed that CTA has not yet been used to capture the knowledge required to perform ultrasound guided…

  4. The value of Retrospective and Concurrent Think Aloud in formative usability testing of a physician data query tool.

    PubMed

    Peute, Linda W P; de Keizer, Nicolette F; Jaspers, Monique W M

    2015-06-01

    To compare the performance of the Concurrent (CTA) and Retrospective (RTA) Think Aloud method and to assess their value in a formative usability evaluation of an Intensive Care Registry-physician data query tool designed to support ICU quality improvement processes. Sixteen representative intensive care physicians participated in the usability evaluation study. Subjects were allocated to either the CTA or RTA method by a matched randomized design. Each subject performed six usability-testing tasks of varying complexity in the query tool in a real-working context. Methods were compared with regard to number and type of problems detected. Verbal protocols of CTA and RTA were analyzed in depth to assess differences in verbal output. Standardized measures were applied to assess thoroughness in usability problem detection weighted per problem severity level and method overall effectiveness in detecting usability problems with regard to the time subjects spent per method. The usability evaluation of the data query tool revealed a total of 43 unique usability problems that the intensive care physicians encountered. CTA detected unique usability problems with regard to graphics/symbols, navigation issues, error messages, and the organization of information on the query tool's screens. RTA detected unique issues concerning system match with subjects' language and applied terminology. The in-depth verbal protocol analysis of CTA provided information on intensive care physicians' query design strategies. Overall, CTA performed significantly better than RTA in detecting usability problems. CTA usability problem detection effectiveness was 0.80 vs. 0.62 (p<0.05) respectively, with an average difference of 42% less time spent per subject compared to RTA. In addition, CTA was more thorough in detecting usability problems of a moderate (0.85 vs. 0.7) and severe nature (0.71 vs. 0.57). In this study, the CTA is more effective in usability-problem detection and provided clarification of intensive care physician query design strategies to inform redesign of the query tool. However, CTA does not outperform RTA. The RTA additionally elucidated unique usability problems and new user requirements. Based on the results of this study, we recommend the use of CTA in formative usability evaluation studies of health information technology. However, we recommend further research on the application of RTA in usability studies with regard to user expertise and experience when focusing on user profile customized (re)design. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. High spatial resolution time-resolved magnetic resonance angiography of lower extremity tumors at 3T

    PubMed Central

    Wu, Gang; Jin, Teng; Li, Ting; Morelli, John; Li, Xiaoming

    2016-01-01

    Abstract The aim of this study was to compare diagnostic value of high spatial resolution time-resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol to Computed tomography angiography (CTA) for preoperative evaluation of lower extremity tumors. This prospective study was approved by the institutional review board. Fifty consecutive patients (31 men, 19 women, age range 18–80 years, average age 42.7 years) with lower extremity tumors underwent TWIST magnetic resonance angiography (MRA) and CTA. Digital subtraction angiography was available for 8 patients. Image quality of MRA was compared with CTA by 2 radiologists according to a 4-point Likert scale. Arterial involvement by tumor was compared using kappa test between MRA and CTA. The ability to identify feeding arteries and arterio-venous fistulae (AVF) was compared using Wilcoxon signed rank test and McNemar test, respectively. Image quality of MRA and CTA was rated without a statistically significant difference (3.88 ± 0.37 vs. 3.97 ± 0.16, P = 0.135). Intramodality agreement was high for the identification of arterial invasion (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers found AVF in 27 of 50 MRA cases and 14 of 50 CTA cases (P < 0.001). Mean feeding arteries identified with MRA were significantly more than that with CTA (2.08 ± 1.72 vs. 1.62 ± 1.52, P = .02). TWIST MRA is a reliable imaging modality for the assessment of lower extremity tumors. TWIST MRA is comparable to CTA for the identification of AVF and feeding arteries. PMID:27631262

  6. [COMPARISON OF FEMORAL CONDYLAR TWIST ANGLE IN THREE DIMENSIONAL RECONSTRUCTION DIGITAL MODELS OF KNEE JOINT BASED ON TWO DIMENSIONAL IMAGES OF MRI AND CT].

    PubMed

    Huang, Zan; Li, Yanlin; Hu, Meng; Li, Jian; You, Zhimin; Wang, Guoliang; He, Chuan

    2015-02-01

    To study the difference of femoral condylar twist angle (CTA) measurement in three dimensional (3-D) reconstruction digital models of human knee joint based on the two dimensional (2-D) images of MRI and CT so as to provide a reference for selecting the best method of CTA measurement in preoperative design for the femoral prosthesis rotational position. The CTA of 10 human cadaveric knee joint was measured in 3-D digital models based on MRI (group A), in 3-D digital models based on CT (group B), in the cadaveric knee joint with cartilage (group C), and in the cadaveric knee joint without cartilage (group D), respectively. The statistical analysis of the differences was made among the measurements of the CTA. The CTA values measured in 3-D digital models were (6.43 ± 0.53) degrees in group A and (3.31 ± 1.07) degrees in group B, showing significant difference (t = 10.235, P = 0.000). The CTA values measured in the cadaveric knee joint were (5.21 ± 1.28) degrees in group C and (3.33 ± 1.12) degrees in group D, showing significant difference (t = 5.770, P = 0.000). There was significant difference in the CTA values between group B and group C (t = 5.779, P = 0.000), but no significant difference was found between group A and group C (t = 3.219, P = 0.110). The CTA values measured in the 3-D digital models based on MRI are closer to the actual values measured in the knee joint with cartilage, and benefit for preoperative plan.

  7. Prediction of vascular abnormalities on CT angiography in patients with acute headache.

    PubMed

    Alons, Imanda M E; Goudsmit, Ben F J; Jellema, Korné; van Walderveen, Marianne A A; Wermer, Marieke J H; Algra, Ale

    2018-05-09

    Patients with acute headache increasingly undergo CT-angiography (CTA) to evaluate underlying vascular causes. The aim of this study is to determine clinical and non-contrast CT (NCCT) criteria to select patients who might benefit from CTA. We retrospectively included patients with acute headache who presented to the emergency department of an academic medical center and large regional teaching hospital and underwent NCCT and CTA. We identified factors that increased the probability of finding a vascular abnormality on CTA, performed multivariable regression analyses and determined discrimination with the c-statistic. A total of 384 patients underwent NCCT and CTA due to acute headache. NCCT was abnormal in 194 patients. Among these, we found abnormalities in 116 cases of which 99 aneurysms. In the remaining 190 with normal NCCT we found abnormalities in 12 cases; four unruptured aneurysms, three cerebral venous thrombosis', two reversible cerebral vasoconstriction syndromes, two cervical arterial dissections and one cerebellar infarction. In multivariable analysis abnormal NCCT, lowered consciousness and presentation within 6 hr of headache onset were independently associated with abnormal CTA. The c-statistic of abnormal NCCT alone was 0.80 (95% CI: 0.75-0.80), that also including the other two variables was 0.84 (95% CI: 0.80-0.88). If NCCT was normal no other factors could help identify patients at risk for abnormalities. In patients with acute headache abnormal NCCT is the strongest predictor of a vascular abnormality on CTA. If NCCT is normal no other predictors increase the probability of finding an abnormality on CTA and diagnostic yield is low. © 2018 The Authors. Brain and Behavior published by Wiley Periodicals, Inc.

  8. Cost-effectiveness of angiographic imaging in isolated perimesencephalic subarachnoid hemorrhage.

    PubMed

    Kalra, Vivek B; Wu, Xiao; Forman, Howard P; Malhotra, Ajay

    2014-12-01

    The purpose of this study is to perform a comprehensive cost-effectiveness analysis of all possible permutations of computed tomographic angiography (CTA) and digital subtraction angiography imaging strategies for both initial diagnosis and follow-up imaging in patients with perimesencephalic subarachnoid hemorrhage on noncontrast CT. Each possible imaging strategy was evaluated in a decision tree created with TreeAge Pro Suite 2014, with parameters derived from a meta-analysis of 40 studies and literature values. Base case and sensitivity analyses were performed to assess the cost-effectiveness of each strategy. A Monte Carlo simulation was conducted with distributional variables to evaluate the robustness of the optimal strategy. The base case scenario showed performing initial CTA with no follow-up angiographic studies in patients with perimesencephalic subarachnoid hemorrhage to be the most cost-effective strategy ($5422/quality adjusted life year). Using a willingness-to-pay threshold of $50 000/quality adjusted life year, the most cost-effective strategy based on net monetary benefit is CTA with no follow-up when the sensitivity of initial CTA is >97.9%, and CTA with CTA follow-up otherwise. The Monte Carlo simulation reported CTA with no follow-up to be the optimal strategy at willingness-to-pay of $50 000 in 99.99% of the iterations. Digital subtraction angiography, whether at initial diagnosis or as part of follow-up imaging, is never the optimal strategy in our model. CTA without follow-up imaging is the optimal strategy for evaluation of patients with perimesencephalic subarachnoid hemorrhage when modern CT scanners and a strict definition of perimesencephalic subarachnoid hemorrhage are used. Digital subtraction angiography and follow-up imaging are not optimal as they carry complications and associated costs. © 2014 American Heart Association, Inc.

  9. Evaluation of dynamic infrared thermography as an alternative to CT angiography for perforator mapping in breast reconstruction: a clinical study.

    PubMed

    Weum, Sven; Mercer, James B; de Weerd, Louis

    2016-07-15

    The current gold standard for preoperative perforator mapping in breast reconstruction with a DIEP flap is CT angiography (CTA). Dynamic infrared thermography (DIRT) is an imaging method that does not require ionizing radiation or contrast injection. We evaluated if DIRT could be an alternative to CTA in perforator mapping. Twenty-five patients scheduled for secondary breast reconstruction with a DIEP flap were included. Preoperatively, the lower abdomen was examined with hand-held Doppler, DIRT and CTA. Arterial Doppler sound locations were marked on the skin. DIRT examination involved rewarming of the abdominal skin after a mild cold challenge. The locations of hot spots on DIRT were compared with the arterial Doppler sound locations. The rate and pattern of rewarming of the hot spots were analyzed. Multiplanar CT reconstructions were used to see if hot spots were related to perforators on CTA. All flaps were based on the perforator selected with DIRT and the surgical outcome was analyzed. First appearing hot spots were always associated with arterial Doppler sounds and clearly visible perforators on CTA. The hot spots on DIRT images were always slightly laterally located in relation to the exit points of the associated perforators through the rectus abdominis fascia on CTA. Some periumbilical perforators were not associated with hot spots and showed communication with the superficial inferior epigastric vein on CTA. The selected perforators adequately perfused all flaps. This study confirms that perforators selected with DIRT have arterial Doppler sound, are clearly visible on CTA and provide adequate perfusion for DIEP breast reconstruction. Retrospectively registered at ClinicalTrials.gov with identifier NCT02806518 .

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fraga, Carlos G.; Sego, Landon H.; Hoggard, Jamin C.

    Dimethyl methylphosphonate (DMMP) was used as a chemical threat agent (CTA) simulant for a first look at the effects of real-world factors on the recovery and exploitation of a CTA’s impurity profile for source matching. Four stocks of DMMP having different impurity profiles were disseminated as aerosols onto cotton, painted wall board, and nylon coupons according to a thorough experimental design. The DMMP-exposed coupons were then solvent extracted and analyzed for DMMP impurities by comprehensive 2-D gas chromatography/mass spectrometry (GC×GC/MS). The similarities between the coupon DMMP impurity profiles and the known (reference) DMMP profiles were measured by dot products ofmore » the coupon profiles and known profiles and by score values obtained from principal component analysis. One stock, with a high impurity-profile selectivity value of 0.9 out of 1, had 100% of its respective coupons correctly classified and no false positives from other coupons. Coupons from the other three stocks with low selectivity values (0.0073, 0.012, and 0.018) could not be sufficiently distinguished from one another for reliable matching to their respective stocks. The results from this work support that: (1) extraction solvents, if not appropriately selected, can have some of the same impurities present in a CTA reducing a CTA’s useable impurity profile, (2) low selectivity among a CTA’s known impurity profiles will likely make definitive source matching impossible in some real-world conditions, (3) no detrimental chemical-matrix interference was encountered during the analysis of actual office media, (4) a short elapsed time between release and sample storage is advantageous for the recovery of the impurity profile because it minimizes volatilization of forensic impurities, and (5) forensic impurity profiles weighted towards higher volatility impurities are more likely to be altered by volatilization following CTA exposure.« less

  11. Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

    PubMed Central

    Henak, C.R.; Abraham, C.L.; Peters, C.L.; Sanders, R.K.; Weiss, J.A.; Anderson, A.E.

    2014-01-01

    AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (~5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98–6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required. PMID:25070373

  12. Origin of the sphere-to-rod transition in cationic micelles with aromatic counterions: specific ion hydration in the interfacial region matters.

    PubMed

    Geng, Yan; Romsted, Laurence S; Froehner, Sandro; Zanette, Dino; Magid, Linda J; Cuccovia, Iolanda M; Chaimovich, Hernan

    2005-01-18

    Sphere-to-rod transitions of cetyltrimethylammonium (CTA+) micelles with dichlorobenzoate counterions are remarkably substituent dependent. Simultaneous estimates of the interfacial molarities of H2O, MeOH, and Cl- and 2,6- and 3,5-dichlorobenzoate (2,6OBz and 3,5OBz) counterions were obtained by the chemical trapping method in mixed micelles of CTACl/CTA3,5OBz and CTACl/CTA2,6OBz without added salt. Increasing the CTA3,5OBz mole fraction produces a marked concurrent increase in interfacial 3,5OBz- and a decrease in interfacial H2O concentrations through the sphere-to-rod transition. No abrupt concentration changes are observed with increasing CTA2,6OBz mole fraction. Counterion-specific changes in the interfacial water concentration may be a major contributor to the delicate balance of forces governing micellar morphology.

  13. 17 CFR 240.17Ad-10 - Prompt posting of certificate detail to master securityholder files, maintenance of accurate...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... between co-transfer agents and recordkeeping transfer agents, maintenance of current control book...-transfer agents and recordkeeping transfer agents, maintenance of current control book, retention of certificate detail and “buy-in” of physical over-issuance. (a)(1) Every recordkeeping transfer agent shall...

  14. Induction of cancer testis antigen expression in circulating acute myeloid leukemia blasts following hypomethylating agent monotherapy

    PubMed Central

    Srivastava, Pragya; Paluch, Benjamin E.; Matsuzaki, Junko; James, Smitha R.; Collamat-Lai, Golda; Blagitko-Dorfs, Nadja; Ford, Laurie Ann; Naqash, Rafeh; Lübbert, Michael; Karpf, Adam R.; Nemeth, Michael J.; Griffiths, Elizabeth A.

    2016-01-01

    Cancer testis antigens (CTAs) are promising cancer associated antigens in solid tumors, but in acute myeloid leukemia, dense promoter methylation silences their expression. Leukemia cell lines exposed to HMAs induce expression of CTAs. We hypothesized that AML patients treated with standard of care decitabine (20mg/m2 per day for 10 days) would demonstrate induced expression of CTAs. Peripheral blood blasts serially isolated from AML patients treated with decitabine were evaluated for CTA gene expression and demethylation. Induction of NY-ESO-1 and MAGEA3/A6, were observed following decitabine. Re-expression of NY-ESO-1 and MAGEA3/A6 was associated with both promoter specific and global (LINE-1) hypomethylation. NY-ESO-1 and MAGEA3/A6 mRNA levels were increased irrespective of clinical response, suggesting that these antigens might be applicable even in patients who are not responsive to HMA therapy. Circulating blasts harvested after decitabine demonstrate induced NY-ESO-1 expression sufficient to activate NY-ESO-1 specific CD8+ T-cells. Induction of CTA expression sufficient for recognition by T-cells occurs in AML patients receiving decitabine. Vaccination against NY-ESO-1 in this patient population is feasible. PMID:26883197

  15. 77 FR 43903 - Intent To Prepare an Environmental Impact Statement for Proposed Transit Improvements to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-26

    ... Administration (FTA), as the lead federal agency, and the Chicago Transit Authority (CTA) published a Notice of... interested parties that the EIS will no longer be a Tier 1 EIS as originally proposed. The methodology and... analysis are available on the CTA Web site www.transitchicago.com/rpmproject . The CTA operates the rapid...

  16. 17 CFR Appendix C to Part 4 - Form CTA-PR

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 1 2014-04-01 2014-04-01 false Form CTA-PR C Appendix C to Part 4 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION COMMODITY POOL OPERATORS AND COMMODITY TRADING ADVISORS Pt. 4, App. C Appendix C to Part 4—Form CTA-PR ER24FE12.052 ER24FE12...

  17. Childhood-onset Takayasu arteritis: an update.

    PubMed

    Mathew, Ashish J; Goel, Ruchika; Kumar, Sathish; Danda, Debashish

    2016-02-01

    Childhood-onset Takayasu arteritis (c-TA) is a distinct subset affecting a wide age group, ranging from young infants to adolescents and it differs from adult TA in many aspects. There is scarcity of data on c-TA worldwide. The disease is classified using the European League Against Rheumatism/Pediatric Rheumatology International Trials Organization/Pediatric Rheumatology European Society criteria. The non-specific nature of presenting complaints and lack of appropriate biomarkers delay the early diagnosis of this illness and many children present with complications, which become irreversible once they set in. One of the largest cohorts of 40 children with c-TA from our center reports hypertension as the commonest presenting feature. Systemic symptoms like headache, fever and weight loss are also described. Assessment of disease in c-TA is done by correlating clinical features with raised inflammatory markers. Advanced imaging plays an important role in diagnosis. In c-TA, the role of magnetic resonance angiography is advocated, taking into consideration the enormous amount of radiation exposure with other modalities. Complications of c-TA include cardiovascular, pulmonary, neurological and those arising secondary to long-term steroid and immunosuppression therapy. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  18. Re-evaluation of the reward comparison hypothesis for alcohol abuse.

    PubMed

    He, Alan Bo-Han; Chang, Yu-Chieh; Meng, Anna Wan Yun; Huang, Andrew Chih Wei

    2017-08-14

    This study examined whether various doses of ethanol induced reward or aversion and then evaluated Grigson's reward comparison hypothesis (1997). Rats were given a 0.1% saccharin solution (conditioned stimulus 1 [CS1]) 15min prior to administration of a 0, 0.05, 0.125, 0.20, 0.35, or 0.50g/kg dose of ethanol (unconditioned stimulus [US]). The rats were then exposed to a paired compartment (CS2) for 30min. The low dose of 0.05g/kg ethanol did not induce conditioned suppression (i.e., conditioned taste aversion [CTA]) or conditioned place preference (CPP). The dose of 0.125g/kg ethanol induced CPP but not CTA. High doses of ethanol, including 0.35g/kg and 0.50g/kg, produced CTA but not CPP. The middle dose of 0.20g/kg ethanol simultaneously induced CTA and CPP. As a result, the reward comparison hypothesis cannot explain the present finding that the middle dose of ethanol induced CTA and CPP. Meanwhile, the high doses of ethanol induced motivationally aversive CTA but not rewarding CPP. The reward comparison hypothesis should be updated further. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. SCA8 Repeat Expansion: Large CTA/CTG Repeat Alleles Are More Common in Ataxic Patients, Including Those with SCA6

    PubMed Central

    Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi

    2003-01-01

    We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85–399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as α1A-voltage–dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients. PMID:12545428

  20. SCA8 repeat expansion: large CTA/CTG repeat alleles are more common in ataxic patients, including those with SCA6.

    PubMed

    Izumi, Yuishin; Maruyama, Hirofumi; Oda, Masaya; Morino, Hiroyuki; Okada, Takayuki; Ito, Hidefumi; Sasaki, Iwao; Tanaka, Hiroyasu; Komure, Osamu; Udaka, Fukashi; Nakamura, Shigenobu; Kawakami, Hideshi

    2003-03-01

    We analyzed the SCA8 CTA/CTG repeat in a large group of Japanese subjects. The frequency of large alleles (85-399 CTA/CTG repeats) was 1.9% in spinocerebellar ataxia (SCA), 0.4% in Parkinson disease, 0.3% in Alzheimer disease, and 0% in a healthy control group; the frequency was significantly higher in the group with SCA than in the control group. Homozygotes for large alleles were observed only in the group with SCA. In five patients with SCA from two families, a large SCA8 CTA/CTG repeat and a large SCA6 CAG repeat coexisted. Age at onset was correlated with SCA8 repeats rather than SCA6 repeats in these five patients. In one of these families, at least one patient showed only a large SCA8 CTA/CTG repeat allele, with no large SCA6 CAG repeat allele. We speculate that the presence of a large SCA8 CTA/CTG repeat allele influences the function of channels such as alpha(1A)-voltage-dependent calcium channel through changing or aberrant splicing, resulting in the development of cerebellar ataxia, especially in homozygous patients.

  1. Brain-derived neurotrophic factor into adult neocortex strengthens a taste aversion memory.

    PubMed

    Martínez-Moreno, Araceli; Rodríguez-Durán, Luis F; Escobar, Martha L

    2016-01-15

    Nowadays, it is known that brain derived neurotrophic-factor (BDNF) is a protein critically involved in regulating long-term memory related mechanisms. Previous studies from our group in the insular cortex (IC), a brain structure of the temporal lobe implicated in acquisition, consolidation and retention of conditioned taste aversion (CTA), demonstrated that BDNF is essential for CTA consolidation. Recent studies show that BDNF-TrkB signaling is able to mediate the enhancement of memory. However, whether BDNF into neocortex is able to enhance aversive memories remains unexplored. In the present work, we administrated BDNF in a concentration capable of inducing in vivo neocortical LTP, into the IC immediately after CTA acquisition in two different conditions: a "strong-CTA" induced by 0.2M lithium chloride i.p. as unconditioned stimulus, and a "weak-CTA" induced by 0.1M lithium chloride i.p. Our results show that infusion of BDNF into the IC converts a weak CTA into a strong one, in a TrkB receptor-dependent manner. The present data suggest that BDNF into the adult insular cortex is sufficient to increase an aversive memory-trace. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Aortic Center: specialized care improves outcomes and decreases mortality

    PubMed Central

    Sales, Marcela da Cunha; Frota Filho, José Dario; Aguzzoli, Cristiane; Souza, Leonardo Dornelles; Rösler, Álvaro Machado; Lucio, Eraldo Azevedo; Leães, Paulo Ernesto; Pontes, Mauro Ricardo Nunes; Lucchese, Fernando Antônio

    2014-01-01

    Objective To compare in-hospital outcomes in aortic surgery in our cardiac surgery unit, before and after foundation of our Center for Aortic Surgery (CTA). Methods Prospective cohort with non-concurrent control. Foundation of CTA required specialized training of surgical, anesthetic and intensive care unit teams, routine neurological monitoring, endovascular and hybrid facilities, training of the support personnel, improvement of the registry and adoption of specific protocols. We included 332 patients operated on between: January/2003 to December/2007 (before-CTA, n=157, 47.3%); and January/2008 to December/2010 (CTA, n=175, 52.7%). Baseline clinical and demographic data, operative variables, complications and in-hospital mortality were compared between both groups. Results Mean age was 58±14 years, with 65% male. Group CTA was older, had higher rate of diabetes, lower rates of COPD and HF, more non-urgent surgeries, endovascular procedures, and aneurysms. In the univariate analysis, CTA had lower mortality (9.7 vs. 23.0%, P=0.008), which occurred consistently across different diseases and procedures. Other outcomes which were reduced in CTA included lower rates of reinterventions (5.7 vs 11%, P=0.046), major complications (20.6 vs. 33.1%, P=0.007), stroke (4.6 vs. 10.9%, P=0.045) and sepsis (1.7 vs. 9.6%, P=0.001), as compared to before-CTA. Multivariable analysis adjusted for potential counfounders revealed that CTA was independently associated with mortality reduction (OR=0.23, IC 95% 0.08 – 0.67, P=0.007). CTA independent mortality reduction was consistent in the multivariable analysis stratified by disease (aneurysm, OR=0.18, CI 95% 0.03 – 0.98, P=0.048; dissection, OR=0.31, CI 95% 0.09 – 0.99, P=0.049) and by procedure (hybrid, OR=0.07, CI 95% 0.007 – 0.72, P=0.026; Bentall, OR=0.18, CI 95% 0.038 – 0.904, P=0.037). Additional multivariable predictors of in-hospital mortality included creatinine (OR=1.7 [1.1-2.6], P=0.008), urgent surgery (OR=5.0 [1.5-16.7], P=0.008) and thoracoabdominal aneurysm (OR=24.6 [3.1-194.1], P=0.002). Conclusion Thoracic aorta surgery in specialized center was associated with lower incidence of complications and all-cause mortality as compared to usual care. PMID:25714201

  3. Acute, but not chronic, exposure to d-cycloserine facilitates extinction and modulates spontaneous recovery of a conditioned taste aversion.

    PubMed

    Mickley, G Andrew; Remus, Jennifer L; Ramos, Linnet; Wilson, Gina N; Biesan, Orion R; Ketchesin, Kyle D

    2012-01-18

    D-cycloserine, the glutamate N-methyl-D-aspartate receptor partial agonist, has been reported to facilitate the extinction of learned fears acquired in both naturalistic and laboratory settings. The current study extended this literature by evaluating the ability of either chronic or acute administrations of DCS to modulate the extinction and spontaneous recovery of a conditioned taste aversion (CTA). Twenty-three hour fluid-deprived Sprague-Dawley rats acquired a strong CTA following 3 pairings of a conditioned stimulus (CS; 0.3% oral saccharin)+unconditioned stimulus [US; 81 mg/kg (i.p.) lithium chloride (LiCl)]. In separate groups of rats, we then employed 2 different extinction paradigms: (1) CS-only (CSO-EXT) in which saccharin was presented every-other day, or (2) Explicitly Unpaired (EU-EXT) in which both saccharin and LiCl were presented but on alternate days. Previous studies have indicated that the EU-EXT procedure speeds up the extinction process. Further, spontaneous recovery of a CTA emerges following CSO-EXT but the EU-EXT paradigm causes a suppression of spontaneous recovery. DCS (15 mg/kg, i.p.) was administered immediately after daily liquid presentations (saccharin or water, alternate days) during the extinction period. In an acute drug manipulation, DCS (15 mg/kg, i.p.) or saline control injections were administered for 4 days only. This was done during one of 3 different phases of extinction [i.e., static (2-5%), early dynamic (8-16%), or middle dynamic (20-40%) saccharin reacceptance]. Other animals assigned to the chronic DCS condition received daily DCS (15 mg/kg, i.p.) throughout extinction. Changes in saccharin drinking in these animals were compared to the data from rats that received no drug (saline controls). Once rats met our criterion for asymptotic extinction (90% reacceptance of the CS) they entered a 30-day latency period during which they received water for 1 h/day. The day after the completion of the latency period, a final opportunity to drink saccharin was provided (spontaneous recovery test). Saline-treated control rats that went through the EU-EXT procedure achieved asymptotic extinction more quickly than did the CSO-EXT rats and did not exhibit a spontaneous recovery of the CTA. Chronic DCS treatments did not significantly reduce the time to achieve asymptotic CTA extinction in rats exposed to either CSO or EU extinction methods. Further, animals treated with DCS throughout EU-EXT exhibited a spontaneous recovery of the CTA whereas the saline-treated, EU-EXT rats did not. Thus, chronic DCS treatment did not shorten the time to extinguish a CTA and this treatment eliminated the ability of EU-EXT to block spontaneous recovery of the CTA. Acute DCS treatments were more effective in reducing the time required to extinguish a CTA than were chronic drug treatments. Moreover, the timing of these acute DCS treatments affected spontaneous recovery of the CTA depending on the extinction method employed. Acute DCS administrations later in extinction were more effective in reducing spontaneous recovery than were early administrations if the rats went through the CSO-EXT procedure. However, late-in-extinction administrations of DCS facilitated spontaneous recovery of the CTA in rats that experienced the EU-EXT method. These data agree with other findings suggesting that DCS treatments are more effective when administered a limited number of times. Our data extend these findings to the CTA paradigm and further suggest that, depending on the extinction paradigm employed, acute exposure to DCS can speed up CTA extinction and reduce spontaneous recovery of the aversion. The timing of the acute DCS treatment during extinction is generally less important than its duration in predicting the rate of CTA extinction. However, the timing of acute DCS treatments during extinction and the method of extinction employed can interact to affect spontaneous recovery of a CTA. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Consequences of repeated ethanol exposure during early or late adolescence on conditioned taste aversions in rats.

    PubMed

    Saalfield, Jessica; Spear, Linda

    2015-12-01

    Alcohol use is prevalent during adolescence, yet little is known about possible long-lasting consequences. Recent evidence suggests that adolescents are less sensitive than adults to ethanol's aversive effects, an insensitivity that may be retained into adulthood after repeated adolescent ethanol exposure. This study assessed whether intermittent ethanol exposure during early or late adolescence (early-AIE or late-AIE, respectively) would affect ethanol conditioned taste aversions 2 days (CTA1) and >3 weeks (CTA2) post-exposure using supersaccharin and saline as conditioning stimuli (CS), respectively. Pair-housed male Sprague-Dawley rats received 4g/kg i.g. ethanol (25%) or water every 48 h from postnatal day (P) 25-45 (early AIE) or P45-65 (late AIE), or were left non-manipulated (NM). During conditioning, 30 min home cage access to the CS was followed by 0, 1, 1.5, 2 or 2.5g/kg ethanol i.p., with testing 2 days later. Attenuated CTA relative to controls was seen among early and late AIE animals at both CTA1 and CTA2, an effect particularly pronounced at CTA1 after late AIE. Thus, adolescent exposure to ethanol was found to induce an insensitivity to ethanol CTA seen soon after exposure and lasting into adulthood, and evident with ethanol exposures not only early but also later in adolescence. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    PubMed

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, <50 HU) volume, and remodelling index. Plaques were qualitatively assessed for CTA features of disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P < 0.0001). Clinically stable patients commonly manifest plaques with features of disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  6. High pressure study of a highly energetic nitrogen-rich carbon nitride, cyanuric triazide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laniel, Dominique; Desgreniers, Serge; Downie, Laura E.

    Cyanuric triazide (CTA), a nitrogen-rich energetic material, was compressed in a diamond anvil cell up to 63.2 GPa. Samples were characterized by x-ray diffraction, Raman, and infrared spectroscopy. A phase transition occurring between 29.8 and 30.7 GPa was found by all three techniques. The bulk modulus and its pressure derivative of the low pressure phase were determined by fitting the 300 K isothermal compression data to the Birch-Murnaghan equation of state. Due to the strong photosensitivity of CTA, synchrotron generated x-rays and visible laser radiation both lead to the progressive conversion of CTA into a two dimensional amorphous C=N network,more » starting from 9.2 GPa. As a result of the conversion, increasingly weak and broad x-ray diffraction lines were recorded from crystalline CTA as a function of pressure. Hence, a definite structure could not be obtained for the high pressure phase of CTA. Results from infrared spectroscopy carried out to 40.5 GPa suggest the high pressure formation of a lattice built of tri-tetrazole molecular units. The decompression study showed stability of the high pressure phase down to 13.9 GPa. Finally, two CTA samples, one loaded with neon and the other with nitrogen, used as pressure transmitting media, were laser-heated to approximately 1100 K and 1500 K while compressed at 37.7 GPa and 42.0 GPa, respectively. In both cases CTA decomposed resulting in amorphous compounds, as recovered at ambient conditions.« less

  7. Computed tomography and magnetic resonance angiography in the evaluation of aberrant origin of the external carotid artery branches.

    PubMed

    Cappabianca, Salvatore; Scuotto, Assunta; Iaselli, Francesco; Pignatelli di Spinazzola, Nicoletta; Urraro, Fabrizio; Sarti, Giuseppe; Montemarano, Marcella; Grassi, Roberto; Rotondo, Antonio

    2012-07-01

    Aim of our study was to evaluate the prevalence of aberrant origin of the branches of the external carotid artery (ECA) in 97 patients by computed tomography (CTA) and magnetic resonance angiography (MRA) and to compare the accuracy of these two techniques in the visualization of the ECA system. All patients underwent CTA and MRA examination of the head and neck. Multiplanar and volumetric reformations were obtained in all cases. For each set of images, the presence of aberrant origin of the branches of the external carotid artery was investigated. MRA and CTA images of each patient were compared to define their information content. Anatomical anomalies were found in 88 heminecks, with a prevalence of 53.3%. In the 61 patients in whom the CTA was performed before the MRA, the latter method showed only 92% of abnormalities detected at the first examination; in the 36 patients in whom MRA was performed first, CTA identified all of the anomalies highlighted by the former, adding 12 new. Knowledge of the anomalies of origin of the ECA branches is essential for the head and neck surgeon; the high prevalence of anomalies found in our series as in the previous studies indicates the opportunity to perform a CTA or a MRA of the head and neck before any surgical or interventional procedure. CTA is the method of choice in the evaluation of anomalies of origin of the branches of the ECA and in the definition of their course.

  8. Multiphase whole-body CT angiography before multiorgan retrieval in clinically brain dead patients: Role and influence on clinical practice.

    PubMed

    Tache, A; Badet, N; Azizi, A; Behr, J; Verdy, S; Delabrousse, E

    2016-06-01

    To evaluate the contribution of multiphase whole-body CT angiography (CTA) for identifying the contra-indications to multiorgan retrieval (MOR) and improving the preoperative organ harvesting strategy. One hundred and eleven consecutive patients who were clinically brain dead underwent multiphase whole-body CTA to confirm the diagnosis of brain death and for assessment of MOR. The CTA protocol included volumetric acquisitions of the brain and abdominopelvic cavity without IV administration of iodinated contrast material, then images of the thorax-abdomen-pelvis 25s after IV contrast administration, of the brain at 60s and finally an abdominopelvic CT acquisition at 90s. The diagnosis of brain death was based on well-established criteria. The assessment of thorax, abdomen and pelvis was based on a systematic checklist. Post-processing imaging techniques were used in all patients. No organs were retrieved from 21 patients due to patient refusal (19%). Twenty-two potential MOR were denied because of general contra-indications including 12/22 (54%) based on CTA criteria alone. Finally, 68 patients were eligible for MOR and 160 organs were harvested. The exclusion of specific organs was based on CTA alone for 2/16 livers, 4/70 kidneys and 5/55 lungs. Fifty hearts and 58 pancreases were not harvested, none based on CTA results alone. Hepatic abnormalities and vascular anatomical variants were identified in 10% of patients. At least one renal artery variant was found in 28% of patients, 13% presented with a double renal vein and 8% with a hepato-mesenteric artery. Multiphase whole-body CTA for MOR is based on the simultaneous association of cerebral CTA to determine brain death with CTA of the thorax, abdomen and pelvis. This rapid, standardized and easily accessible procedure has no harmful effects on harvested kidneys. It makes it possible to select the donors and the organs to be harvested and allows the retrieving surgeon to identify and anticipate technical difficulties. Copyright © 2015 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  9. Sex Differences in Functional Stress Test Versus CT Angiography in Symptomatic Patients With Suspected CAD: Insights From PROMISE

    PubMed Central

    Pagidipati, Neha J.; Hemal, Kshipra; Coles, Adrian; Mark, Daniel B.; Dolor, Rowena J.; Pellikka, Patricia A.; Hoffmann, Udo; Litwin, Sheldon E.; Udelson, James; Daubert, Melissa A.; Shah, Svati H.; Martinez, Beth; Lee, Kerry L.; Douglas, Pamela S.

    2016-01-01

    Background Risk stratification is an important goal of cardiac noninvasive tests (NITs), yet little contemporary data exist on the prognostic value of different NITs by patient sex. Objectives To compare the results and prognostic information derived from anatomic versus stress testing in stable men and women with suspected coronary artery disease. Methods In 8966 PROMISE trial patients tested as randomized (4500 computed tomographic angiography [CTA], 52% female; 4466 stress testing, 53% female), we assessed the relationship between sex and NIT results using logistic regression, and the relationship between sex and a composite of death, myocardial infarction, and unstable angina hospitalization using Cox proportional hazards models. Results In women, a positive CTA (≥70% stenosis) was less likely than a positive stress test (8% vs. 12%, adjusted OR 0.67 [95% CI 0.55-0.82]). Compared with negative tests, a positive CTA was more strongly associated with subsequent clinical events than a positive stress test (CTA adjusted HR 5.86 [95% CI 3.32-10.35]; stress adjusted HR 2.27 [95% CI 1.21-4.25]; adjusted p=0.028). Men were more likely to have a positive CTA than stress test (16% vs. 14%, adjusted OR 1.23 [95% CI 1.04-1.47]). Compared with negative tests, a positive CTA was less strongly associated with subsequent clinical events than a positive stress test in men, although this difference was not statistically significant (CTA adjusted HR 2.80 [95% CI 1.76-4.45]; stress adjusted HR 4.42 [95% CI 2.77-7.07]; adjusted p=0.168). Negative CTA and stress tests were equally likely to predict an event in both sexes (adjusted p-values=NS). A significant interaction between sex, NIT type, and test result (p=0.01) suggests that sex and NIT type jointly influence the relationship between test result and clinical events. Conclusions The prognostic value of an NIT result varies by test type and patient sex. Women appear to derive more prognostic information from a CTA, while men tend to derive similar prognostic value from both test types. PMID:27058908

  10. An innovative method of planning and displaying flap volume in DIEP flap breast reconstructions.

    PubMed

    Hummelink, S; Verhulst, Arico C; Maal, Thomas J J; Hoogeveen, Yvonne L; Schultze Kool, Leo J; Ulrich, Dietmar J O

    2017-07-01

    Determining the ideal volume of the harvested flap to achieve symmetry in deep inferior epigastric artery perforator (DIEP) flap breast reconstructions is complex. With preoperative imaging techniques such as 3D stereophotogrammetry and computed tomography angiography (CTA) available nowadays, we can combine information to preoperatively plan the optimal flap volume to be harvested. In this proof-of-concept, we investigated whether projection of a virtual flap planning onto the patient's abdomen using a projection method could result in harvesting the correct flap volume. In six patients (n = 9 breasts), 3D stereophotogrammetry and CTA data were combined from which a virtual flap planning was created comprising perforator locations, blood vessel trajectory and flap size. All projected perforators were verified with Doppler ultrasound. Intraoperative flap measurements were collected to validate the determined flap delineation volume. The measured breast volume using 3D stereophotogrammetry was 578 ± 127 cc; on CTA images, 527 ± 106 cc flap volumes were planned. The nine harvested flaps weighed 533 ± 109 g resulting in a planned versus harvested flap mean difference of 5 ± 27 g (flap density 1.0 g/ml). In 41 out of 42 projected perforator locations, a Doppler signal was audible. This proof-of-concept shows in small numbers that flap volumes can be included into a virtual DIEP flap planning, and transferring the virtual planning to the patient through a projection method results in harvesting approximately the same volume during surgery. In our opinion, this innovative approach is the first step in consequently achieving symmetric breast volumes in DIEP flap breast reconstructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Practical considerations for optimizing cardiac computed tomography protocols for comprehensive acquisition prior to transcatheter aortic valve replacement.

    PubMed

    Khalique, Omar K; Pulerwitz, Todd C; Halliburton, Sandra S; Kodali, Susheel K; Hahn, Rebecca T; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Leon, Martin B; D'Souza, Belinda; Einstein, Andrew J

    2016-01-01

    Transcatheter aortic valve replacement (TAVR) is performed frequently in patients with severe, symptomatic aortic stenosis who are at high risk or inoperable for open surgical aortic valve replacement. Computed tomography angiography (CTA) has become the gold standard imaging modality for pre-TAVR cardiac anatomic and vascular access assessment. Traditionally, cardiac CTA has been most frequently used for assessment of coronary artery stenosis, and scanning protocols have generally been tailored for this purpose. Pre-TAVR CTA has different goals than coronary CTA and the high prevalence of chronic kidney disease in the TAVR patient population creates a particular need to optimize protocols for a reduction in iodinated contrast volume. This document reviews details which allow the physician to tailor CTA examinations to maximize image quality and minimize harm, while factoring in multiple patient and scanner variables which must be considered in customizing a pre-TAVR protocol. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. The Cognition and Neuroergonomics (CaN) Collaborative Technology Alliance (CTA): Scientific Vision, Approach, and Translational Paths

    DTIC Science & Technology

    2012-09-01

    The Cognition and Neuroergonomics (CaN) Collaborative Technology Alliance (CTA): Scientific Vision, Approach, and Translational Paths by...The Cognition and Neuroergonomics (CaN) Collaborative Technology Alliance (CTA): Scientific Vision, Approach, and Translational Paths Kelvin S. Oie...REPORT DATE (DD-MM-YYYY) September 2012 2. REPORT TYPE Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE The Cognition and Neuroergonomics

  13. Spin-powered Pulsars in the CTA Era

    NASA Astrophysics Data System (ADS)

    Romani, Roger W.

    2016-04-01

    What can CTA do for the study of isolated and binary neutron stars? Are the recent Crab observations the vanguard of numerous strong pulsed detections in the CTA era? Will the typical pulsar show only the tail of the Fermi spectrum? Or will we be tantalized by a handful of new unusual sources? I review our current HE picture and suggest that pulsar binaries represent a new TeV frontier.

  14. Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.

    PubMed

    Ellmann, Stephan; Kammerer, Ferdinand; Allmendinger, Thomas; Brand, Michael; Janka, Rolf; Hammon, Matthias; Lell, Michael M; Uder, Michael; Kramer, Manuel

    2016-10-01

    This study aimed to determine the degree of radiation dose reduction in neck CT angiography (CTA) achievable with Sinogram-affirmed iterative reconstruction (SAFIRE) algorithms. 10 consecutive patients scheduled for neck CTA were included in this study. CTA images of the external carotid arteries either were reconstructed with filtered back projection (FBP) at full radiation dose level or underwent simulated dose reduction by proprietary reconstruction software. The dose-reduced images were reconstructed using either SAFIRE 3 or SAFIRE 5 and compared with full-dose FBP images in terms of vessel definition. 5 observers performed a total of 3000 pairwise comparisons. SAFIRE allowed substantial radiation dose reductions in neck CTA while maintaining vessel definition. The possible levels of radiation dose reduction ranged from approximately 34 to approximately 90% and depended on the SAFIRE algorithm strength and the size of the vessel of interest. In general, larger vessels permitted higher degrees of radiation dose reduction, especially with higher SAFIRE strength levels. With small vessels, the superiority of SAFIRE 5 over SAFIRE 3 was lost. Neck CTA can be performed with substantially less radiation dose when SAFIRE is applied. The exact degree of radiation dose reduction should be adapted to the clinical question, in particular to the smallest vessel needing excellent definition.

  15. Spot sign on 90-second delayed computed tomography angiography improves sensitivity for hematoma expansion and mortality: prospective study.

    PubMed

    Ciura, Viesha A; Brouwers, H Bart; Pizzolato, Raffaella; Ortiz, Claudia J; Rosand, Jonathan; Goldstein, Joshua N; Greenberg, Steven M; Pomerantz, Stuart R; Gonzalez, R Gilberto; Romero, Javier M

    2014-11-01

    The computed tomography angiography (CTA) spot sign is a validated biomarker for poor outcome and hematoma expansion in intracerebral hemorrhage. The spot sign has proven to be a dynamic entity, with multimodal imaging proving to be of additional value. We investigated whether the addition of a 90-second delayed CTA acquisition would capture additional intracerebral hemorrhage patients with the spot sign and increase the sensitivity of the spot sign. We prospectively enrolled consecutive intracerebral hemorrhage patients undergoing first pass and 90-second delayed CTA for 18 months at a single academic center. Univariate and multivariate logistic regression were performed to assess clinical and neuroimaging covariates for relationship with hematoma expansion and mortality. Sensitivity of the spot sign for hematoma expansion on first pass CTA was 55%, which increased to 64% if the spot sign was present on either CTA acquisition. In multivariate analysis the spot sign presence was associated with significant hematoma expansion: odds ratio, 17.7 (95% confidence interval, 3.7-84.2; P=0.0004), 8.3 (95% confidence interval, 2.0-33.4; P=0.004), and 12.0 (95% confidence interval, 2.9-50.5; P=0.0008) if present on first pass, delayed, or either CTA acquisition, respectively. Spot sign presence on either acquisitions was also significant for mortality. We demonstrate improved sensitivity for predicting hematoma expansion and poor outcome by adding a 90-second delayed CTA, which may enhance selection of patients who may benefit from hemostatic therapy. © 2014 American Heart Association, Inc.

  16. Computed Tomographic Angiography of the Pancreas in Cats with Chronic Diabetes Mellitus Compared to Normal Cats.

    PubMed

    Secrest, S; Sharma, A; Bugbee, A

    2018-03-02

    Diabetes mellitus (DM) is a common endocrinopathy in cats. No known diagnostic test or patient characteristic at the time of diagnosis can predict likely disease course, unlike in people in whom computed tomographic angiography (CTA) is used. No published data exist regarding the CTA appearance of the pancreas in cats with DM, and thus, it is unknown what if any CTA variables should be further assessed for associations with pancreatic endocrine function. A significant difference in pancreatic attenuation, volume, and size will be identified between normal cats and those with chronic DM on CTA. Ten healthy control cats and 15 cats with naturally occurring DM present for >12 months. Prospective cross-sectional study comparing pancreatic attenuation, enhancement pattern, size, volume, pancreatic volume-to-body weight ratio (V:BW), pancreatic arterial: portal phase ratio (A:P), time-to-arterial enhancement, and time-to-peak portal enhancement on CTA between sedated healthy control cats and those with chronic DM. The pancreas in cats with chronic DM was significantly larger, had higher volume, higher V:BW, and shorter time-to-peak portal enhancement on CTA when compared to normal cats. Peak portal enhancement time, pancreatic size, pancreatic volume, and V:BW can be used to differentiate normal sedated cats from those with chronic DM by CTA. These variables warrant further investigation to identify possible associations with endocrine function. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Late Protein Synthesis-Dependent Phases in CTA Long-Term Memory: BDNF Requirement

    PubMed Central

    Martínez-Moreno, Araceli; Rodríguez-Durán, Luis F.; Escobar, Martha L.

    2011-01-01

    It has been proposed that long-term memory (LTM) persistence requires a late protein synthesis-dependent phase, even many hours after memory acquisition. Brain-derived neurotrophic factor (BDNF) is an essential protein synthesis product that has emerged as one of the most potent molecular mediators for long-term synaptic plasticity. Studies in the rat hippocampus have been shown that BDNF is capable to rescue the late-phase of long-term potentiation as well as the hippocampus-related LTM when protein synthesis was inhibited. Our previous studies on the insular cortex (IC), a region of the temporal cortex implicated in the acquisition and storage of conditioned taste aversion (CTA), have demonstrated that intracortical delivery of BDNF reverses the deficit in CTA memory caused by the inhibition of IC protein synthesis due to anisomycin administration during early acquisition. In this work, we first analyze whether CTA memory storage is protein synthesis-dependent in different time windows. We observed that CTA memory become sensible to protein synthesis inhibition 5 and 7 h after acquisition. Then, we explore the effect of BDNF delivery (2 μg/2 μl per side) in the IC during those late protein synthesis-dependent phases. Our results show that BDNF reverses the CTA memory deficit produced by protein synthesis inhibition in both phases. These findings support the notion that recurrent rounds of consolidation-like events take place in the neocortex for maintenance of CTA memory trace and that BDNF is an essential component of these processes. PMID:21960964

  18. Coronary Computed Tomographic Angiography-Derived Fractional Flow Reserve for Therapeutic Decision Making.

    PubMed

    Tesche, Christian; Vliegenthart, Rozemarijn; Duguay, Taylor M; De Cecco, Carlo N; Albrecht, Moritz H; De Santis, Domenico; Langenbach, Marcel C; Varga-Szemes, Akos; Jacobs, Brian E; Jochheim, David; Baquet, Moritz; Bayer, Richard R; Litwin, Sheldon E; Hoffmann, Ellen; Steinberg, Daniel H; Schoepf, U Joseph

    2017-12-15

    This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD. The therapeutic strategy (optimal medical therapy alone vs revascularization) and the appropriate revascularization procedure (percutaneous coronary intervention vs coronary artery bypass grafting) were selected using cCTA-CT-FFR. Thirty-six patients (49%) had a functionally significant CAD based on ICA-FFR. cCTA-CT-FFR correctly identified a functionally significant CAD and the need of revascularization in 35 of 36 patients (97%). When revascularization was deemed indicated, the same revascularization procedure (32 percutaneous coronary interventions and 3 coronary artery bypass grafting) was chosen in 35 of 35 patients (100%). Overall, identical management strategies were selected in 73 of the 74 patients (99%). cCTA-CT-FFR shows excellent performance to identify patients with and without the need for revascularization and to select the appropriate revascularization strategy. cCTA-CT-FFR as a noninvasive "one-stop shop" has the potential to change diagnostic workflows and to directly inform therapeutic decision making in patients with suspected CAD. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The diagnostic accuracy and outcomes after coronary computed tomography angiography vs. conventional functional testing in patients with stable angina pectoris: a systematic review and meta-analysis.

    PubMed

    Nielsen, Lene H; Ortner, Nino; Nørgaard, Bjarne L; Achenbach, Stephan; Leipsic, Jonathon; Abdulla, Jawdat

    2014-09-01

    To systematically review and perform a meta-analysis of the diagnostic accuracy and post-test outcomes of conventional exercise electrocardiography (XECG) and single-photon emission computed tomography (SPECT) compared with coronary computed tomography angiography (coronary CTA) in patients suspected of stable coronary artery disease (CAD). We systematically searched for studies published from January 2002 to February 2013 examining the diagnostic accuracy (defined as at least ≥50% luminal obstruction on invasive coronary angiography) and outcomes of coronary CTA (≥16 slice) in comparison with XECG and SPECT. The search revealed 11 eligible studies (N = 1575) comparing the diagnostic accuracy and 7 studies (N = 216.603) the outcomes of coronary CTA vs. XECG or/and SPECT. The per-patient sensitivity [95% confidence interval (95% CI)] to identify significant CAD was 98% (93-99%) for coronary CTA vs. 67% (54-78%) (P < 0.001) for XECG and 99% (96-100%) vs. 73% (59-83%) (P = 0.001) for SPECT. The specificity (95% CI) of coronary CTA was 82% (63-93%) vs. 46% (30-64%) (P < 0.001) for XECG and 71% (60-80%) vs. 48% (31-64%) (P = 0.14) for SPECT. The odds ratio (OR) of downstream test utilization (DTU) for coronary CTA vs. XECG/SPECT was 1.38 (1.33-1.43, P < 0.001), for revascularization 2.63 (2.50-2.77, P < 0.001), for non-fatal myocardial infarction 0.53 (0.39-0.72, P < 0.001), and for all-cause mortality 1.01 (0.87-1.18, P = 0.87). The up-front diagnostic performance of coronary CTA is higher than of XECG and SPECT. When compared with XECG/SPECT testing, coronary CTA testing is associated with increased DTU and coronary revascularization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  20. Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal.

    PubMed

    Kaemmerer, Nadine; Brand, Michael; Hammon, Matthias; May, Matthias; Wuest, Wolfgang; Krauss, Bernhard; Uder, Michael; Lell, Michael M

    2016-10-01

    Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.

  1. 18F-FDG-PET/CT angiography in the diagnosis of infective endocarditis and cardiac device infection in adult patients with congenital heart disease and prosthetic material.

    PubMed

    Pizzi, María N; Dos-Subirà, L; Roque, Albert; Fernández-Hidalgo, Nuria; Cuéllar-Calabria, Hug; Pijuan Domènech, Antonia; Gonzàlez-Alujas, María T; Subirana-Domènech, M T; Miranda-Barrio, B; Ferreira-González, Ignacio; González-López, Juan J; Igual, Albert; Maisterra-Santos, Olga; García-Dorado, David; Castell-Conesa, Joan; Almirante, Benito; Escobar Amores, Manuel; Tornos, Pilar; Aguadé-Bruix, Santiago

    2017-12-01

    Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18 F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. "No zone" approach in penetrating neck trauma reduces unnecessary computed tomography angiography and negative explorations.

    PubMed

    Ibraheem, Kareem; Khan, Muhammad; Rhee, Peter; Azim, Asad; O'Keeffe, Terence; Tang, Andrew; Kulvatunyou, Narong; Joseph, Bellal

    2018-01-01

    The most recent management guidelines advocate computed tomography angiography (CTA) for any suspected vascular or aero-digestive injuries in all zones and give zone II injuries special consideration. We hypothesized that physical examination can safely guide CTA use in a "no zone" approach. An 8-year retrospective analysis of all adult trauma patients with penetrating neck trauma (PNT) was performed. We included all patients in whom the platysma was violated. Patients were classified into three groups as follows: hard signs, soft signs, and asymptomatic. CTA use, positive CTA (contrast extravasation, dissection, or intimal flap) and operative details were reported. Primary outcomes were positive CTA and therapeutic neck exploration (TNE) (defined by repair of major vascular or aero-digestive injuries). A total of 337 patients with PNT met the inclusion criteria. Eighty-two patients had hard signs and all of them went to the operating room, of which 59 (72%) had TNE. One hundred fifty-six patients had soft signs, of which CTA was performed in 121 (78%), with positive findings in 12 (10%) patients. The remaining 35 (22%) underwent initial neck exploration, of which 14 (40%) were therapeutic yielding a high rate of negative exploration. Ninty-nine patients were asymptomatic, of which CTA was performed in 79 (80%), with positive findings in 3 (4%), however, none of these patients required TNE. On sub analysis based on symptoms, there was no difference in the rate of TNE between the neck zones in patients with hard signs (P = 0.23) or soft signs (P = 0.51). Regardless of the zone of injury, asymptomatic patients did not require a TNE. Physical examination regardless of the zone of injury should be the primary guide to CTA or TNE in patients with PNT. Following traditional zone-based guidelines can result in unnecessary negative explorations in patients with soft signs and may need rethinking. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. When are CT angiograms indicated for patients with lower extremity fractures? A review of 275 extremities.

    PubMed

    Monazzam, Shafagh; Goodell, Parker B; Salcedo, Edgardo S; Nelson, Sandahl H; Wolinsky, Philip R

    2017-01-01

    Computed tomography angiogram (CTA) is frequently utilized to detect vascular injuries even without examination findings indicating a vascular injury. We had the following hypotheses: (1) a CTA for lower extremity fractures with no clinical signs of a vascular injury is not indicated, and (2) fracture location and pattern would correlate with the risk of a vascular injury. A retrospective review was conducted on patients who had an acute lower extremity fracture(s) and a CTA. Their charts were reviewed for multiple factors including the presence or absence of hard or soft signs of a vascular injury, soft tissue status, and fracture location/pattern. Every CTA radiology report was reviewed and any vascular intervention or amputation resulting from a vascular injury was recorded. Statistical analysis was performed. Of the 275 CTAs of fractured extremities reviewed, 80 (29%) had a positive CTA finding and 16 (6%) required treatment. A total of 109 (40%) of the extremities had no hard or soft signs; all had normal CTAs. Having at least one hard or soft sign was a significant risk factor for having a positive CTA. An open fracture, isolated proximal third fibula fracture, distal and shaft tibia fractures, and the presence of multiple fractures in one extremity were also associated with an increased risk for having a positive CTA. We found no evidence to support the routine use of CTAs to evaluate lower extremity fractures unless at least one hard or soft sign is present. The presence of an open fracture, distal tibia or tibial shaft fractures, multiple fractures in one extremity, and/or an isolated proximal third fibula fracture increases the risk of having a finding consistent with a vascular injury on a CTA. Only 6% of the cases required treatment, and all of them had diminished or absent distal pulses on presentation. Diagnostic test, level III.

  4. Incremental diagnostic quality gain of CTA over V/Q scan in the assessment of pulmonary embolism by means of a Wells score Bayesian model: results from the ACDC collaboration.

    PubMed

    Cochon, Laila; McIntyre, Kaitlin; Nicolás, José M; Baez, Amado Alejandro

    2017-08-01

    Our objective was to evaluate the diagnostic value of computed tomography angiography (CTA) and ventilation perfusion (V/Q) scan in the assessment of pulmonary embolism (PE) by means of a Bayesian statistical model. Wells criteria defined pretest probability. Sensitivity and specificity of CTA and V/Q scan for PE were derived from pooled meta-analysis data. Likelihood ratios calculated for CTA and V/Q were inserted in the nomogram. Absolute (ADG) and relative diagnostic gains (RDG) were analyzed comparing post- and pretest probability. Comparative gain difference was calculated for CTA ADG over V/Q scan integrating ANOVA p value set at 0.05. The sensitivity for CT was 86.0% (95% CI: 80.2%, 92.1%) and specificity of 93.7% (95% CI: 91.1%, 96.3%). The V/Q scan yielded a sensitivity of 96% (95% CI: 95%, 97%) and a specificity of 97% (95% CI: 96%, 98%). Bayes nomogram results for CTA were low risk and yielded a posttest probability of 71.1%, an ADG of 56.1%, and an RDG of 374%, moderate-risk posttest probability was 85.1%, an ADG of 56.1%, and an RDG of 193.4%, and high-risk posttest probability was 95.2%, an ADG of 36.2%, and an RDG of 61.35%. The comparative gain difference for low-risk population was 46.1%; in moderate-risk 41.6%; and in high-risk a 22.1% superiority. ANOVA analysis for LR+ and LR- showed no significant difference (p = 0.8745, p = 0.9841 respectively). This Bayesian model demonstrated a superiority of CTA when compared to V/Q scan for the diagnosis of pulmonary embolism. Low-risk patients are recognized to have a superior overall comparative gain favoring CTA.

  5. 17 CFR 240.17Ac2-2 - Annual reporting requirement for registered transfer agents.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... inaccurate, incomplete, or misleading. A transfer agent may file an amendment at any time; however, in order... for registered transfer agents. 240.17Ac2-2 Section 240.17Ac2-2 Commodity and Securities Exchanges... Organizations § 240.17Ac2-2 Annual reporting requirement for registered transfer agents. (a) Every transfer...

  6. Biomimetic PEGylation of carbon nanotubes through surface-initiated RAFT polymerization.

    PubMed

    Shi, Yingge; Zeng, Guanjian; Xu, Dazhuang; Liu, Meiying; Wang, Ke; Li, Zhen; Fu, Lihua; Zhang, Qingsong; Zhang, Xiaoyong; Wei, Yen

    2017-11-01

    Carbon nanotubes (CNTs) are a type of one-dimensional carbon nanomaterials that possess excellent physicochemical properties and have been potentially utilized for a variety of applications. Surface modification of CNTs with polymers is a general route to expand and improve the performance of CNTs and has attracted great research interest over the past few decades. Although many methods have been developed previously, most of these methods still showed some disadvantages, such as low efficiency, complex experimental procedure and harsh reaction conditions etc. In this work, we reported a practical and novel way to fabricate CNTs based polymer composites via the combination of mussel inspired chemistry and reversible addition fragmentation chain transfer (RAFT) polymerization. First, the amino group was introduced onto the surface of CNTs via self-polymerization of dopamine. Then, chain transfer agent can be immobilized on the amino groups functionalized CNTs to obtain CNT-PDA-CTA, which can be utilized for surface-initiated RAFT polymerization. A water soluble and biocompatible monomer poly(ethylene glycol) monomethyl ether methacrylate (PEGMA) was adopted to fabricate pPEGMA functionalized CNTs through RAFT polymerization. The successful preparation of CNTs based polymer composites (CNT-pPEGMA) was confirmed by transmission electron microscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis and X-ray photoelectron spectroscopy in details. The CNT-pPEGMA showed good dispersibility and desirable biocompatibility, making them highly potential for biomedical applications. More importantly, a large number of CNTs based polymer composites could also be fabricated through the same strategy when different monomers were used due to the good monomer adaptability of RAFT polymerization. Therefore, this strategy should be a general method for preparation of various multifunctional CNTs based polymer composites. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Comparison of the clinical efficacy of craniotomy and craniopuncture therapy for the early stage of moderate volume spontaneous intracerebral haemorrhage in basal ganglia: Using the CTA spot sign as an entry criterion.

    PubMed

    Ge, Chunyan; Zhao, Wangmiao; Guo, Hong; Sun, Zhaosheng; Zhang, Wanzeng; Li, Xiaowei; Yang, Xuehui; Zhang, Jinrong; Wang, Dongxin; Xiang, Yi; Mao, Jianhui; Zhang, Wenchao; Guo, Hao; Zhang, Yazhao; Chen, Jianchao

    2018-06-01

    Surgical treatment is widely used for haematoma removal in spontaneous intracerebral haemorrhage (ICH) patients, but there is controversy about the selection of surgical methods. The CT angiography (CTA) spot sign has been proven to be a promising factor predicting haematoma expansion and is recommended as an entry criterion for haemostatic therapy in patients with ICH. This trial was designed to evaluate the clinical efficacy of two surgical methods (haematoma removal by craniotomy and craniopuncture combined with urokinase infusion) for patients in the early stage (≤6h from symptom onset) of spontaneous ICH with a moderate haematoma volume (30 ml - 60 ml). From January 2012 to July 2017, 196 eligible patients treated in our institution were enrolled according to the inclusion criteria. The patients were divided into the CTA spot sign positive type and CTA spot sign negative type according to the presence or absence of the CTA spot sign. For each type, the patients were randomly assigned to two groups, i.e., the craniotomy group, in which patients underwent craniotomy with haematoma removal, and the craniopuncture group, in which patients underwent minimally invasive craniopuncture combined with urokinase infusion therapy. Neurological function was evaluated with the Scandinavian Stroke Scale (SSS) at day 14. The disability level and the activities of daily living were assessed using a modified Rankin Scale (mRS) and Barthel Index (BI) at day 90. Case fatalities were recorded at day 14 and 90. Complications were recorded during hospitalization. For the CTA spot sign positive type, the craniotomy group had a higher SSS than that in the craniopuncture group (P < 0.05) at day 14. The rebleeding rate was higher in the craniopuncture group than that in the craniotomy group (P < 0.05) during hospitalization. The craniotomy group had a lower mRS than that in the craniopuncture group (P < 0.01) and had a higher BI than that in the craniopuncture group (P < 0.05) at day 90. There was no statistically significant difference in the fatality rate between the two groups. For the CTA spot sign negative type, there were no significant differences in the SSS, mRS, BI, fatality rate and complication rate between the two groups. ICH can be divided into the CTA spot sign positive and negative type according to the presence or absence of the CTA spot sign. For the CTA spot sign positive type, patients can benefit from craniotomy with haematoma removal, which can reduce the postoperative rebleeding rate and improve the prognosis. For the CTA spot sign negative type, both craniotomy and craniopuncture are applicable. Considering simple procedure and minor surgical injury, craniopuncture can be a more reasonable choice. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. The increased use of computed tomography angiography and magnetic resonance angiography as the sole imaging modalities prior to infrainguinal bypass has had no effect on outcomes.

    PubMed

    Shue, Bing; Damle, Rachelle N; Flahive, Julie; Kalish, Jeffrey A; Stone, David H; Patel, Virendra I; Schanzer, Andres; Baril, Donald T

    2015-08-01

    Angiography remains the gold standard imaging modality before infrainguinal bypass. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have emerged as noninvasive alternatives for preoperative imaging. We sought to examine contemporary trends in the utilization of CTA and MRA as isolated imaging modalities before infrainguinal bypass and to compare outcomes following infrainguinal bypass in patients who underwent CTA or MRA versus those who underwent conventional arteriography. Patients undergoing infrainguinal bypass within the Vascular Study Group of New England were identified (2003-2012). Patients were stratified by preoperative imaging modality: CTA/MRA alone or conventional angiography. Trends in utilization of these modalities were examined and demographics of these groups were compared. Primary end points included primary patency, secondary patency, and major adverse limb events (MALE) at 1 year as determined by Kaplan-Meier analysis. Multivariable Cox proportional hazards models were constructed to evaluate the effect of imaging modality on primary patency, secondary patency, and MALE after adjusting for confounders. In 3123 infrainguinal bypasses, CTA/MRA alone was used in 462 cases (15%) and angiography was used in 2661 cases (85%). Use of CTA/MRA alone increased over time, with 52 (11%) bypasses performed between 2003 and 2005, 189 (41%) bypasses performed between 2006 and 2009, and 221 (48%) bypasses performed between 2010 and 2012 (P < 0.001). Patients with CTA/MRA alone, compared with patients with angiography, more frequently underwent bypass for claudication (33% vs. 26%, P = 0.001) or acute limb ischemia (13% vs. 5%, P < 0.0001), more frequently had prosthetic conduits (39% vs. 30%, P = 0.001), and less frequently had tibial/pedal targets (32% vs. 40%, P = 0.002). After adjusting for these and other confounders, multivariable analysis demonstrated that the use of CTA/MRA alone was not associated with a significant difference in 1 year primary patency (hazard ratio [HR] 0.95, 95% confidence interval [CI] 0.78-1.16), secondary patency (HR 1.30, 95% CI 0.99-1.72), or MALE (HR 1.08, 95% CI 0.89-1.32). CTA and MRA are being increasingly used as the sole preoperative imaging modality before infrainguinal bypass. This shift in practice patterns appears to have no measurable effect on outcomes at 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. A prototype for the real-time analysis of the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Bulgarelli, Andrea; Fioretti, Valentina; Zoli, Andrea; Aboudan, Alessio; Rodríguez-Vázquez, Juan José; Maier, Gernot; Lyard, Etienne; Bastieri, Denis; Lombardi, Saverio; Tosti, Gino; De Rosa, Adriano; Bergamaschi, Sonia; Interlandi, Matteo; Beneventano, Domenico; Lamanna, Giovanni; Jacquemier, Jean; Kosack, Karl; Antonelli, Lucio Angelo; Boisson, Catherine; Burkowski, Jerzy; Buson, Sara; Carosi, Alessandro; Conforti, Vito; Contreras, Jose Luis; De Cesare, Giovanni; de los Reyes, Raquel; Dumm, Jon; Evans, Phil; Fortson, Lucy; Fuessling, Matthias; Graciani, Ricardo; Gianotti, Fulvio; Grandi, Paola; Hinton, Jim; Humensky, Brian; Knödlseder, Jürgen; Malaguti, Giuseppe; Marisaldi, Martino; Neyroud, Nadine; Nicastro, Luciano; Ohm, Stefan; Osborne, Julian; Rosen, Simon; Tacchini, Alessandro; Torresi, Eleonora; Testa, Vincenzo; Trifoglio, Massimo; Weinstein, Amanda

    2014-07-01

    The Cherenkov Telescope Array (CTA) observatory will be one of the biggest ground-based very-high-energy (VHE) γ- ray observatory. CTA will achieve a factor of 10 improvement in sensitivity from some tens of GeV to beyond 100 TeV with respect to existing telescopes. The CTA observatory will be capable of issuing alerts on variable and transient sources to maximize the scientific return. To capture these phenomena during their evolution and for effective communication to the astrophysical community, speed is crucial. This requires a system with a reliable automated trigger that can issue alerts immediately upon detection of γ-ray flares. This will be accomplished by means of a Real-Time Analysis (RTA) pipeline, a key system of the CTA observatory. The latency and sensitivity requirements of the alarm system impose a challenge because of the anticipated large data rate, between 0.5 and 8 GB/s. As a consequence, substantial efforts toward the optimization of highthroughput computing service are envisioned. For these reasons our working group has started the development of a prototype of the Real-Time Analysis pipeline. The main goals of this prototype are to test: (i) a set of frameworks and design patterns useful for the inter-process communication between software processes running on memory; (ii) the sustainability of the foreseen CTA data rate in terms of data throughput with different hardware (e.g. accelerators) and software configurations, (iii) the reuse of nonreal- time algorithms or how much we need to simplify algorithms to be compliant with CTA requirements, (iv) interface issues between the different CTA systems. In this work we focus on goals (i) and (ii).

  10. Subcomponent vaccine based on CTA1-DD adjuvant with incorporated UreB class II peptides stimulates protective Helicobacter pylori immunity.

    PubMed

    Nedrud, John G; Bagheri, Nayer; Schön, Karin; Xin, Wei; Bergroth, Hilda; Eliasson, Dubravka Grdic; Lycke, Nils Y

    2013-01-01

    A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB). The protective efficacy of the selected peptides together with cholera toxin (CT) was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD) that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform.

  11. Subcomponent Vaccine Based on CTA1-DD Adjuvant with Incorporated UreB Class II Peptides Stimulates Protective Helicobacter pylori Immunity

    PubMed Central

    Nedrud, John G.; Bagheri, Nayer; Schön, Karin; Xin, Wei; Bergroth, Hilda; Eliasson, Dubravka Grdic; Lycke, Nils Y.

    2013-01-01

    A mucosal vaccine against Helicobacter pylori infection could help prevent gastric cancers and peptic ulcers. While previous attempts to develop such a vaccine have largely failed because of the requirement for safe and effective adjuvants or large amounts of well defined antigens, we have taken a unique approach to combining our strong mucosal CTA1-DD adjuvant with selected peptides from urease B (UreB). The protective efficacy of the selected peptides together with cholera toxin (CT) was first confirmed. However, CT is a strong adjuvant that unfortunately is precluded from clinical use because of its toxicity. To circumvent this problem we have developed a derivative of CT, the CTA1-DD adjuvant, that has been found safe in non-human primates and equally effective compared to CT when used intranasally. We genetically fused the selected peptides into the CTA1-DD plasmid and found after intranasal immunizations of Balb/c mice using purified CTA1-DD with 3 copies of an H. pylori urease T cell epitope (CTA1-UreB3T-DD) that significant protection was stimulated against a live challenge infection. Protection was, however, weaker than with the gold standard, bacterial lysate+CT, but considering that we only used a single epitope in nanomolar amounts the results convey optimism. Protection was associated with enhanced Th1 and Th17 immunity, but immunizations in IL-17A-deficient mice revealed that IL-17 may not be essential for protection. Taken together, we have provided evidence for the rational design of an effective mucosal subcomponent vaccine against H. pylori infection based on well selected protective epitopes from relevant antigens incorporated into the CTA1-DD adjuvant platform. PMID:24391754

  12. Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion: Cost-Effectiveness Analysis.

    PubMed

    Beyer, Sebastian E; Hunink, Myriam G; Schöberl, Florian; von Baumgarten, Louisa; Petersen, Steffen E; Dichgans, Martin; Janssen, Hendrik; Ertl-Wagner, Birgit; Reiser, Maximilian F; Sommer, Wieland H

    2015-07-01

    This study evaluated the cost-effectiveness of different noninvasive imaging strategies in patients with possible basilar artery occlusion. A Markov decision analytic model was used to evaluate long-term outcomes resulting from strategies using computed tomographic angiography (CTA), magnetic resonance imaging, nonenhanced CT, or duplex ultrasound with intravenous (IV) thrombolysis being administered after positive findings. The analysis was performed from the societal perspective based on US recommendations. Input parameters were derived from the literature. Costs were obtained from United States costing sources and published literature. Outcomes were lifetime costs, quality-adjusted life-years (QALYs), incremental cost-effectiveness ratios, and net monetary benefits, with a willingness-to-pay threshold of $80,000 per QALY. The strategy with the highest net monetary benefit was considered the most cost-effective. Extensive deterministic and probabilistic sensitivity analyses were performed to explore the effect of varying parameter values. In the reference case analysis, CTA dominated all other imaging strategies. CTA yielded 0.02 QALYs more than magnetic resonance imaging and 0.04 QALYs more than duplex ultrasound followed by CTA. At a willingness-to-pay threshold of $80,000 per QALY, CTA yielded the highest net monetary benefits. The probability that CTA is cost-effective was 96% at a willingness-to-pay threshold of $80,000/QALY. Sensitivity analyses showed that duplex ultrasound was cost-effective only for a prior probability of ≤0.02 and that these results were only minimally influenced by duplex ultrasound sensitivity and specificity. Nonenhanced CT and magnetic resonance imaging never became the most cost-effective strategy. Our results suggest that CTA in patients with possible basilar artery occlusion is cost-effective. © 2015 The Authors.

  13. Dissociation between peripheral blood chimerism and tolerance to hindlimb composite tissue transplants: preferential localization of chimerism in donor bone

    PubMed Central

    Rahhal, Dina N.; Xu, Hong; Huang, Wei-Chao; Wu, Shengli; Wen, Yujie; Huang, Yiming; Ildstad, Suzanne T.

    2009-01-01

    Background Mixed chimerism induces donor-specific tolerance to composite tissue allotransplants (CTA). In the present studies, we used a nonmyeloablative conditioning approach to establish chimerism and promote CTA acceptance. Methods WF (RT1Au) rats were conditioned with 600-300 cGy total body irradiation (TBI, day-1), 100 × 106 T cell-depleted ACI (RT1Aabl) bone marrow cells were transplanted day 0, followed by a 11-day course of tacrolimus and one dose of anti-lymphocyte serum (day 10). Heterotopic osteomyocutaneous flap transplantation was performed 4-6 weeks after bone marrow transplantation. Results Mixed chimerism was initially achieved in almost all recipients, but long-term acceptance of CTA was only achieved in rats treated with 600 cGy TBI. When anti-αβ-TCR mAb (day-3) was added into the regimens, donor chimerism was similar to recipients preconditioned without anti-αβ-TCR mAb. However, the long-term CTA survival was significantly improved in chimeras receiving ≥ 300 cGy TBI plus anti-αβ-TCR mAb. Higher levels of donor chimerism were associated with CTA acceptance. The majority of flap-acceptors lost peripheral blood (PB) chimerism within 6 months. However, donor chimerism persisted in transplanted bone at significantly higher levels compared to other hematopoietic compartments. The compartment donor chimerism may be responsible for the maintenance of tolerance to CTA. Long-term acceptors were tolerant to a donor skin graft challenge even in the absence of PB chimerism. Conclusions Mixed chimerism established by nonmyeloablative conditioning induces long-term acceptance of CTA which is associated with persistent chimerism preferentially in transplanted donor bone. PMID:19920776

  14. Alternative diagnoses based on CT angiography of the chest in patients with suspected pulmonary thromboembolism

    PubMed Central

    Ferreira, Eleci Vaz; Gazzana, Marcelo Basso; Sarmento, Muriel Bossle; Guazzelli, Pedro Arends; Hoffmeister, Mariana Costa; Guerra, Vinicius André; Seligman, Renato; Knorst, Marli Maria

    2016-01-01

    Objective : To determine the prevalence of alternative diagnoses based on chest CT angiography (CTA) in patients with suspected pulmonary thromboembolism (PTE) who tested negative for PTE, as well as whether those alternative diagnoses had been considered prior to the CTA. Methods : This was a cross-sectional, retrospective study involving 191 adult patients undergoing CTA for suspected PTE between September of 2009 and May of 2012. Chest X-rays and CTAs were reviewed to determine whether the findings suggested an alternative diagnosis in the cases not diagnosed as PTE. Data on symptoms, risk factors, comorbidities, length of hospital stay, and mortality were collected. Results : On the basis of the CTA findings, PTE was diagnosed in 47 cases (24.6%). Among the 144 patients not diagnosed with PTE via CTA, the findings were abnormal in 120 (83.3%). Such findings were consistent with an alternative diagnosis that explained the symptoms in 75 patients (39.3%). Among those 75 cases, there were only 39 (20.4%) in which the same alterations had not been previously detected on chest X-rays. The most common alternative diagnosis, made solely on the basis of the CTA findings, was pneumonia (identified in 20 cases). Symptoms, risk factors, comorbidities, and the in-hospital mortality rate did not differ significantly between the patients with and without PTE. However, the median hospital stay was significantly longer in the patients with PTE than in those without (18.0 and 9.5 days, respectively; p = 0.001). Conclusions : Our results indicate that chest CTA is useful in cases of suspected PTE, because it can confirm the diagnosis and reveal findings consistent with an alternative diagnosis in a significant number of patients. PMID:26982039

  15. Effect of CTA Tube Current on Spot Sign Detection and Accuracy for Prediction of Intracerebral Hemorrhage Expansion.

    PubMed

    Morotti, A; Romero, J M; Jessel, M J; Brouwers, H B; Gupta, R; Schwab, K; Vashkevich, A; Ayres, A; Anderson, C D; Gurol, M E; Viswanathan, A; Greenberg, S M; Rosand, J; Goldstein, J N

    2016-05-19

    Reduction of CT tube current is an effective strategy to minimize radiation load. However, tube current is also a major determinant of image quality. We investigated the impact of CTA tube current on spot sign detection and diagnostic performance for intracerebral hemorrhage expansion. We retrospectively analyzed a prospectively collected cohort of consecutive patients with primary intracerebral hemorrhage from January 2001 to April 2015 who underwent CTA. The study population was divided into 2 groups according to the median CTA tube current level: low current (<350 mA) and high current (≥350 mA). CTA first-pass readings for spot sign presence were independently analyzed by 2 readers. Baseline and follow-up hematoma volumes were assessed by semiautomated computer-assisted volumetric analysis. Sensitivity, specificity, positive and negative predictive values, and accuracy of spot sign in predicting hematoma expansion were calculated. This study included 709 patients (288 and 421 in the low- and high-current groups, respectively). A higher proportion of low-current scans identified at least 1 spot sign (20.8% versus 14.7%, P = .034), but hematoma expansion frequency was similar in the 2 groups (18.4% versus 16.2%, P = .434). Sensitivity and positive and negative predictive values were not significantly different between the 2 groups. Conversely, high-current scans showed superior specificity (91% versus 84%, P = .015) and overall accuracy (84% versus 77%, P = .038). CTA obtained at high levels of tube current showed better diagnostic accuracy for prediction of hematoma expansion by using spot sign. These findings may have implications for future studies using the CTA spot sign to predict hematoma expansion for clinical trials. © 2016 American Society of Neuroradiology.

  16. Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography.

    PubMed

    Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro

    2018-01-01

    We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.

  17. Plaque imaging with CT—a comprehensive review on coronary CT angiography based risk assessment

    PubMed Central

    Kolossváry, Márton; Szilveszter, Bálint; Merkely, Béla

    2017-01-01

    CT based technologies have evolved considerably in recent years. Coronary CT angiography (CTA) provides robust assessment of coronary artery disease (CAD). Early coronary CTA imaging—as a gate-keeper of invasive angiography—has focused on the presence of obstructive stenosis. Coronary CTA is currently the only non-invasive imaging modality for the evaluation of non-obstructive CAD, which has been shown to contribute to adverse cardiac events. Importantly, improved spatial resolution of CT scanners and novel image reconstruction algorithms enable the quantification and characterization of atherosclerotic plaques. State-of-the-art CT imaging can therefore reliably assess the extent of CAD and differentiate between various plaque features. Recent studies have demonstrated the incremental prognostic value of adverse plaque features over luminal stenosis. Comprehensive coronary plaque assessment holds potential to significantly improve individual risk assessment incorporating adverse plaque characteristics, the extent and severity of atherosclerotic plaque burden. As a result, several coronary CTA based composite risk scores have been proposed recently to determine patients at high risk for adverse events. Coronary CTA became a promising modality for the evaluation of functional significance of coronary lesions using CT derived fractional flow reserve (FFR-CT) and/or rest/dynamic myocardial CT perfusion. This could lead to substantial reduction in unnecessary invasive catheterization procedures and provide information on ischemic burden of CAD. Discordance between the degree of stenosis and ischemia has been recognized in clinical landmark trials using invasive FFR. Both lesion stenosis and composition are possibly related to myocardial ischemia. The evaluation of lesion-specific ischemia using combined functional and morphological plaque information could ultimately improve the diagnostic performance of CTA and thus patient care. In this review we aimed to summarize current evidence on comprehensive coronary artery plaque assessment using coronary CTA. PMID:29255692

  18. Impact of coronary calcium score on the prevalence of coronary artery stenosis on dual source CT coronary angiography in caucasian patients with an intermediate risk.

    PubMed

    Meyer, Mathias; Henzler, Thomas; Fink, Christian; Vliegenthart, Rozemarijn; Barraza, J Michael; Nance, John W; Apfaltrer, Paul; Schoenberg, Stefan O; Wasser, Klaus

    2012-11-01

    To investigate the prevalence of significant coronary artery stenosis on coronary computed tomography angiography (cCTA) in symptomatic Caucasian patients with an intermediate risk score at different levels of coronary artery calcification (CAC). In total, 383 consecutive symptomatic Caucasian patients (147 females, 60 ± 13 years) with an intermediate risk score underwent nonenhanced CT for CAC scoring immediately before contrast-enhanced cCTA on a dual-source CT scanner. Additionally clinically indicated invasive coronary angiography (ICA) was performed in 90 patients. The prevalence of significant coronary artery stenosis (>50%) on cCTA and ICA was correlated at different CAC score levels. Of 121 patients with a zero CAC score, none had significant coronary artery stenosis on cCTA or ICA. Coronary CTA diagnosed in 54 of 70 patients with high CAC score (>400), a significant stenosis. Subsequent ICA confirmed significant stenosis in 30 of 32 patients. Sensitivity and a negative predictive value of CAC score ruling out significant stenosis on cCTA were 100% and 100%, respectively, using cutoff value of zero and specificity and positive predictive value to predict significant stenosis on cCTA were 79% and 51%, respectively, using a cutoff value of >400. Significant coronary artery stenosis is extremely unlikely, with an estimated risk of 4 in 1000 patients in symptomatic Caucasian patients with an intermediate risk score and negative CAC score. To reduce radiation exposure, radiation-free tests should be considered for differential diagnosis of chest pain in these patients. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  19. Case series of 64 slice computed tomography-computed tomographic angiography with 3D reconstruction to diagnose symptomatic cerebral aneurysms: new standard of care?

    PubMed Central

    Jehle, Dietrich; Chae, Floria; Wai, Jonathan; Cloud, Sam; Pierce, David; Meyer, Michael

    2012-01-01

    CT angiography (CTA) has improved significantly over the past few years such that the reconstructed images of the cerebral arteries may now be equivalent to conventional digital angiography. The new technology of 64 slice multi-detector CTA can reconstruct detailed images that can reliably identify small cerebral aneurysms, even those <3mm. In addition, it is estimated that CT followed by lumbar puncture (LP) misses up to 4% of symptomatic aneurysms. We present a series of cases that illustrates how CT followed by CTA may be replacing CT-LP as the standard of care in working up patients for symptomatic cerebral aneurysms and the importance of performing three dimensional (3D) reconstructions. A series of seven cases of symptomatic cerebral aneurysms were identified that illustrate the sensitivity of CT-CTA versus CT-LP and the importance of 3D reconstruction in identifying these aneurysms. Surgical treatment was recommended for 6 of the 7 patients with aneurysms and strict hypertension control was recommended for the seventh patient. Some of these patients demonstrated subarachnoid hemorrhage on presentation while others had negative LPs. A number of these patients with negative LPs were clearly symptomatic from their aneurysms. At least one of these cerebral aneurysms was not apparent on CTA without 3D reconstruction. 3D reconstruction of CTA is crucial to adequately identify cerebral aneurysms. This case series helps reinforce the importance of 3D reconstruction. There is some data to suggest that 64 slice CT-CTA may be equivalent or superior to CT-LP in the detection of symptomatic cerebral aneurysms. PMID:22593806

  20. Evaluating the use and utility of noninvasive angiography in diagnosing traumatic blunt cerebrovascular injury.

    PubMed

    Wang, Anthony C; Charters, Michael A; Thawani, Jayesh P; Than, Khoi D; Sullivan, Stephen E; Graziano, Gregory P

    2012-06-01

    Digital subtraction angiography (DSA) is the gold standard for radiographic diagnosis of blunt cerebrovascular injury (BCVI), but use of computed tomography angiography (CTA) and magnetic resonance angiography (MRA) has increased dramatically in BCVI screening. This study explores the utility, effectiveness, and cost of noninvasive CTA and MRA screening for BCVI. Medical records of 2,025 consecutive adults evaluated for acute blunt neck trauma and BCVI were reviewed retrospectively. The incidence of BCVI, level(s) of cervical injury, involvement of foramina transversaria and internal carotid canals, presence of bony dislocation or subluxation, and subsequent treatment received were assessed. Asymptomatic patients were analyzed based on fracture and injury patterns. The cost effectiveness of CTA compared with DSA and the effects of CTA sensitivity and screening yield were determined. Of reviewed patients, 196 received CTA or MRA. Thirty-eight patients (19.4%) were diagnosed with BCVI. Screening yield in patients symptomatic at presentation was 48.8%. Large-vessel internal carotid, vertebral, anterior spinal, and basilar artery occlusion were associated with a positive screen, as were concurrent stroke and spinal cord injury (p < 0.01). Of patients with injuries found with noninvasive imaging, 50.0% of BCVI involved C1-3 fracture, 34.2% involved subluxation, and 65.8% involved foramina transversaria. In both symptomatic and asymptomatic patients, CTA screening was more cost effective than DSA. Noninvasive imaging is a safe, accurate, and cost-effective tool for BCVI screening. Symptomatic presentation was the best predictor of BCVI. Significant cost savings were realized using CTA rather than DSA, with similar effectiveness and patient outcomes. Diagnostic study, level III; economic analysis, level IV. Copyright © 2012 by Lippincott Williams & Wilkins

  1. Diagnostic Accuracy of CT Coronary Angiography According to Pretest Probability of Coronary Artery Disease and Severity of Coronary Arterial Calcification: The CorE-64 International, Multicenter Study

    PubMed Central

    Arbab-Zadeh, Armin; Miller, Julie M; Rochitte, Carlos E; Dewey, Marc; Niinuma, Hiroyuki; Gottlieb, Ilan; Paul, Narinder; Clouse, Melvin E.; Shapiro, Edward P.; Hoe, John; Lardo, Albert C.; Bush, David E.; de Roos, Albert; Cox, Christopher; Brinker, Jeffrey; Lima, Joăo A. C.

    2012-01-01

    Objectives Assess the impact of patient population characteristics on accuracy by CT angiography (CTA) to detect obstructive coronary artery disease (CAD). Background The ability of CTA to exclude obstructive CAD in patients of different pretest probabilities and in presence of coronary calcification remains uncertain. Methods For the CorE-64 study 371 patients underwent CTA and cardiac catheterization for the detection of obstructive CAD defined as 50% or greater luminal stenosis by quantitative coronary angiography (QCA). This analysis includes 80 initially excluded patients with a calcium score ≥ 600. Area under the receiver-operating-characteristics curve (AUC) was used to evaluate CTA diagnostic accuracy compared to QCA in patients according to calcium score and pretest probability of CAD. Results Analysis of patient-based quantitative CTA accuracy revealed an AUC of 0.93 (95% confidence interval [CI] 0.90-0.95). AUC remained 0.93 (0.90-0.96) after excluding patients with known CAD but decreased to 0.81 (0.71-0.89) in patients with calcium score ≥ 600 (p=0.077). While AUC were similar (0.93, 0.92, and 0.93, respectively) for patients with intermediate, high pretest probability for CAD, and known CAD, negative predictive values were different: 0.90, 0.83, and 0.50, respectively. Negative predictive values decreased from 0.93 to 0.75 for patients with calcium score < or ≥ 100, respectively (p= 0.053). Conclusions Both pretest probability for CAD and coronary calcium scoring should be considered before using CTA for excluding obstructive CAD. CTA is less effective for this purpose in patients with calcium score ≥ 600 and in patients with a high pretest probability for obstructive CAD. PMID:22261160

  2. A standardized Hippophae extract (SBL-1) counters neuronal tissue injuries and changes in neurotransmitters: implications in radiation protection.

    PubMed

    Bala, Madhu; Gupta, Vanita; Prasad, Jagdish

    2017-12-01

    Effects of a radioprotective, standardized leaf extract (code SBL-1) from traditional medicinal plant, sea buckthorn [Hippophae rhamnoides L. (Elaeagnaceae)], on neurotransmitters and brain injuries in rats showing radiation-induced conditioned taste aversion (CTA), are not known. Understanding CTA in rats is important because its process is considered parallel to nausea and vomiting in humans. This study investigated the levels of neurotransmitters, antioxidant defences and histological changes in rats showing radiation CTA, and their modification by SBL-1. The inbred male Sprague-Dawley rats (age 65 days, weighing 190 ± 10 g) were used. Saccharin-preferring rats were selected using standard procedure and divided into groups. Group I (untreated control) was administered sterile water, group II was 60 Co-γ-irradiated (2 Gy), and group III was administered SBL-1 before irradiation. Observations were recorded up to day 5. Irradiation (2 Gy) caused (i) non-recoverable CTA (≥ 64.7 ± 5.0%); (ii) degenerative changes in cerebral cortex, amygdala and hippocampus; (iii) increases in brain dopamine (DA, 63.4%), norepinephrine (NE, 157%), epinephrine (E, 233%), plasma NE (103%) and E (160%); and (iv) decreases in brain superoxide dismutase (67%), catalase (60%) and glutathione (51%). SBL-1 treatment (12 mg/kg body weight) 30 min before irradiation (i) countered brain injuries, (ii) reduced CTA (38.7 ± 3.0%, day 1) and (iii) normalized brain DA, NE, E, superoxide dismutase, catalase and CTA from day 3 onwards. Radiation CTA was coupled with brain injuries, disturbances in neurotransmitters and antioxidant defences. SBL-1 pretreatment countered these disturbances, indicating neuroprotective action.

  3. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    PubMed

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  4. Fractional flow reserve by computerized tomography and subsequent coronary revascularization

    PubMed Central

    Packard, René R. Sevag; Li, Dong; Budoff, Matthew J.; Karlsberg, Ronald P.

    2017-01-01

    Aims Fractional flow reserve by computerized tomography (FFR-CT) provides non-invasive functional assessment of the hemodynamic significance of coronary artery stenosis. We determined the FFR-CT values, receiver operator characteristic (ROC) curves, and predictive ability of FFR-CT for actual standard of care guided coronary revascularization. Methods and results Consecutive outpatients who underwent coronary CT angiography (coronary CTA) followed by invasive angiography over a 24-month period from 2012 to 2014 were identified. Studies that fit inclusion criteria (n = 75 patients, mean age 66, 75% males) were sent for FFR-CT analysis, and results stratified by coronary artery calcium (CAC) scores. Coronary CTA studies were re-interpreted in a blinded manner, and baseline FFR-CT values were obtained retrospectively. Therefore, results did not interfere with clinical decision-making. Median FFR-CT values were 0.70 in revascularized (n = 69) and 0.86 in not revascularized (n = 138) coronary arteries (P < 0.001). Using clinically established significance cut-offs of FFR-CT ≤0.80 and coronary CTA ≥70% stenosis for the prediction of clinical decision-making and subsequent coronary revascularization, the positive predictive values were 74 and 88% and negative predictive values were 96 and 84%, respectively. The area under the curve (AUC) for all studied territories was 0.904 for coronary CTA, 0.920 for FFR-CT, and 0.941 for coronary CTA combined with FFR-CT (P = 0.001). With increasing CAC scores, the AUC decreased for coronary CTA but remained higher for FFR-CT (P < 0.05). Conclusion The addition of FFR-CT provides a complementary role to coronary CTA and increases the ability of a CT-based approach to identify subsequent standard of care guided coronary revascularization. PMID:27469588

  5. Acquisition and expression of conditioned taste aversion differentially affects extracellular signal regulated kinase and glutamate receptor phosphorylation in rat prefrontal cortex and nucleus accumbens

    PubMed Central

    Marotta, Roberto; Fenu, Sandro; Scheggi, Simona; Vinci, Stefania; Rosas, Michela; Falqui, Andrea; Gambarana, Carla; De Montis, M. Graziella; Acquas, Elio

    2014-01-01

    Conditioned taste aversion (CTA) can be applied to study associative learning and its relevant underpinning molecular mechanisms in discrete brain regions. The present study examined, by immunohistochemistry and immunocytochemistry, the effects of acquisition and expression of lithium-induced CTA on activated Extracellular signal Regulated Kinase (p-ERK) in the prefrontal cortex (PFCx) and nucleus accumbens (Acb) of male Sprague-Dawley rats. The study also examined, by immunoblotting, whether acquisition and expression of lithium-induced CTA resulted in modified levels of phosphorylation of glutamate receptor subunits (NR1 and GluR1) and Thr34- and Thr75-Dopamine-and-cAMP-Regulated PhosphoProtein (DARPP-32). CTA acquisition was associated with an increase of p-ERK-positive neurons and phosphorylated NR1 receptor subunit (p-NR1) in the PFCx, whereas p-GluR1, p-Thr34- and p-Thr75-DARPP-32 levels were not changed in this brain region. CTA expression increased the number of p-ERK-positive neurons in the shell (AcbSh) and core (AcbC) but left unmodified p-NR1, p-GluR1, p-Thr34- and p-Thr75-DARPP-32 levels. Furthermore, post-embedding immunogold quantitative analysis in AcbSh revealed that CTA expression significantly increased nuclear p-ERK immunostaining as well as p-ERK-labeled axo-spinous contacts. Overall, these results indicate that ERK and NR1, but not GluR1 and DARPP-32, are differentially phosphorylated as a consequence of acquisition and expression of aversive associative learning. Moreover, these results confirm that CTA represents an useful approach to study the molecular basis of associative learning in rats and suggest the involvement of ERK cascade in learning-associated synaptic plasticity. PMID:24847227

  6. Involvement of BDNF signaling transmission from basolateral amygdala to infralimbic prefrontal cortex in conditioned taste aversion extinction.

    PubMed

    Xin, Jian; Ma, Ling; Zhang, Tian-Yi; Yu, Hui; Wang, Yue; Kong, Liang; Chen, Zhe-Yu

    2014-05-21

    Brain-derived neurotrophic factor (BDNF) and its receptor, tropomyosin-related kinase receptor B (TrkB), play a critical role in memory extinction. However, the detailed role of BDNF in memory extinction on the basis of neural circuit has not been fully understood. Here, we aim to investigate the role of BDNF signaling circuit in mediating conditioned taste aversion (CTA) memory extinction of the rats. We found region-specific changes in BDNF gene expression during CTA extinction. CTA extinction led to increased BDNF gene expression in the basolateral amygdala (BLA) and infralimbic prefrontal cortex (IL) but not in the central amygdaloid nucleus (CeA) and hippocampus (HIP). Moreover, blocking BDNF signaling or exogenous microinjection of BDNF into the BLA or IL could disrupt or enhance CTA extinction, which suggested that BDNF signaling in the BLA and IL is necessary and sufficient for CTA extinction. Interestingly, we found that microinjection of BDNF-neutralizing antibody into the BLA could abolish the extinction training-induced BDNF mRNA level increase in the IL, but not vice versa, demonstrating that BDNF signaling is transmitted from the BLA to IL during extinction. Finally, the accelerated extinction learning by infusion of exogenous BDNF in the BLA could also be blocked by IL infusion of BDNF-neutralizing antibody rather than vice versa, indicating that the IL, but not BLA, is the primary action site of BDNF in CTA extinction. Together, these data suggest that BLA-IL circuit regulates CTA memory extinction by identifying BDNF as a key regulator. Copyright © 2014 the authors 0270-6474/14/347302-12$15.00/0.

  7. Diagnostic Accuracy of Computer Tomography Angiography and Magnetic Resonance Angiography in the Stenosis Detection of Autologuous Hemodialysis Access: A Meta-Analysis

    PubMed Central

    Liu, Shiyuan

    2013-01-01

    Purpose To compare the diagnostic performances of computer tomography angiography (CTA) and magnetic resonance angiography (MRA) for detection and assessment of stenosis in patients with autologuous hemodialysis access. Materials and Methods Search of PubMed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to May 2013 for studies comparing CTA or MRA with DSA or surgery for autologuous hemodialysis access. Eligible studies were in English language, aimed to detect more than 50% stenosis or occlusion of autologuous vascular access in hemodialysis patients with CTA and MRA technology and provided sufficient data about diagnosis performance. Methodological quality was assessed by the Quality Assessment of Diagnostic Studies (QUADAS) instrument. Sensitivities (SEN), specificities (SPE), positive likelihood ratio (PLR), negative likelihood values (NLR), diagnostic odds ratio (DOR) and areas under the receiver operator characteristic curve (AUC) were pooled statistically. Potential threshold effect, heterogeneity and publication bias was evaluated. The clinical utility of CTA and MRA in detection of stenosis was also investigated. Result Sixteen eligible studies were included, with a total of 500 patients. Both CTA and MRA were accurate modality (sensitivity, 96.2% and 95.4%, respectively; specificity, 97.1 and 96.1%, respectively; DOR [diagnostic odds ratio], 393.69 and 211.47, respectively) for hemodialysis vascular access. No significant difference was detected between the diagnostic performance of CTA (AUC, 0.988) and MRA (AUC, 0.982). Meta-regression analyses and subgroup analyses revealed no statistical difference. The Deek’s funnel plots suggested a publication bias. Conclusion Diagnostic performance of CTA and MRA for detecting stenosis of hemodialysis vascular access had no statistical difference. Both techniques may function as an alternative or an important complement to conventional digital subtraction angiography (DSA) and may be able to help guide medical management. PMID:24194928

  8. Different Imaging Strategies in Patients With Possible Basilar Artery Occlusion

    PubMed Central

    Beyer, Sebastian E.; Hunink, Myriam G.; Schöberl, Florian; von Baumgarten, Louisa; Petersen, Steffen E.; Dichgans, Martin; Janssen, Hendrik; Ertl-Wagner, Birgit; Reiser, Maximilian F.

    2015-01-01

    Background and Purpose— This study evaluated the cost-effectiveness of different noninvasive imaging strategies in patients with possible basilar artery occlusion. Methods— A Markov decision analytic model was used to evaluate long-term outcomes resulting from strategies using computed tomographic angiography (CTA), magnetic resonance imaging, nonenhanced CT, or duplex ultrasound with intravenous (IV) thrombolysis being administered after positive findings. The analysis was performed from the societal perspective based on US recommendations. Input parameters were derived from the literature. Costs were obtained from United States costing sources and published literature. Outcomes were lifetime costs, quality-adjusted life-years (QALYs), incremental cost-effectiveness ratios, and net monetary benefits, with a willingness-to-pay threshold of $80 000 per QALY. The strategy with the highest net monetary benefit was considered the most cost-effective. Extensive deterministic and probabilistic sensitivity analyses were performed to explore the effect of varying parameter values. Results— In the reference case analysis, CTA dominated all other imaging strategies. CTA yielded 0.02 QALYs more than magnetic resonance imaging and 0.04 QALYs more than duplex ultrasound followed by CTA. At a willingness-to-pay threshold of $80 000 per QALY, CTA yielded the highest net monetary benefits. The probability that CTA is cost-effective was 96% at a willingness-to-pay threshold of $80 000/QALY. Sensitivity analyses showed that duplex ultrasound was cost-effective only for a prior probability of ≤0.02 and that these results were only minimally influenced by duplex ultrasound sensitivity and specificity. Nonenhanced CT and magnetic resonance imaging never became the most cost-effective strategy. Conclusions— Our results suggest that CTA in patients with possible basilar artery occlusion is cost-effective. PMID:26022634

  9. Effectiveness of the clinical teaching associate model to improve clinical learning outcomes: a randomized controlled trial.

    PubMed

    Parchebafieh, Samaneh; Gholizadeh, Leila; Lakdizaji, Sima; Ghiasvandiyan, Shahrzad; Davoodi, Arefeh

    2014-01-01

    This study examined the effectiveness of the clinical teaching associate (CTA) model to improve clinical learning outcomes in nursing students. Students were randomly allocated to either the CTA (n = 28) or traditional training group (n = 32), and their clinical knowledge, skills, and satisfaction with the learning experience were assessed and compared. The results showed that the CTA model was equally effective in improving clinical knowledge, skills, and satisfaction of nursing students.

  10. Anatomical Reproducibility of a Head Model Molded by a Three-dimensional Printer

    PubMed Central

    KONDO, Kosuke; NEMOTO, Masaaki; MASUDA, Hiroyuki; OKONOGI, Shinichi; NOMOTO, Jun; HARADA, Naoyuki; SUGO, Nobuo; MIYAZAKI, Chikao

    We prepared rapid prototyping models of heads with unruptured cerebral aneurysm based on image data of computed tomography angiography (CTA) using a three-dimensional (3D) printer. The objective of this study was to evaluate the anatomical reproducibility and accuracy of these models by comparison with the CTA images on a monitor. The subjects were 22 patients with unruptured cerebral aneurysm who underwent preoperative CTA. Reproducibility of the microsurgical anatomy of skull bone and arteries, the length and thickness of the main arteries, and the size of cerebral aneurysm were compared between the CTA image and rapid prototyping model. The microsurgical anatomy and arteries were favorably reproduced, apart from a few minute regions, in the rapid prototyping models. No significant difference was noted in the measured lengths of the main arteries between the CTA image and rapid prototyping model, but errors were noted in their thickness (p < 0.001). A significant difference was also noted in the longitudinal diameter of the cerebral aneurysm (p < 0.01). Regarding the CTA image as the gold standard, reproducibility of the microsurgical anatomy of skull bone and main arteries was favorable in the rapid prototyping models prepared using a 3D printer. It was concluded that these models are useful tools for neurosurgical simulation. The thickness of the main arteries and size of cerebral aneurysm should be comprehensively judged including other neuroimaging in consideration of errors. PMID:26119896

  11. Activation of Cell Surface Bound 20S Proteasome Inhibits Vascular Cell Growth and Arteriogenesis

    PubMed Central

    Ito, Wulf D.; Lund, Natalie; Zhang, Ziyang; Buck, Friedrich; Lellek, Heinrich; Horst, Andrea; Machens, Hans-Günther; Schunkert, Heribert; Schaper, Wolfgang; Meinertz, Thomas

    2015-01-01

    Arteriogenesis is an inflammatory process associated with rapid cellular changes involving vascular resident endothelial progenitor cells (VR-EPCs). Extracellular cell surface bound 20S proteasome has been implicated to play an important role in inflammatory processes. In our search for antigens initially regulated during collateral growth mAb CTA 157-2 was generated against membrane fractions of growing collateral vessels. CTA 157-2 stained endothelium of growing collateral vessels and the cell surface of VR-EPCs. CTA 157-2 bound a protein complex (760 kDa) that was identified as 26 kDa α7 and 21 kDa β3 subunit of 20S proteasome in mass spectrometry. Furthermore we demonstrated specific staining of 20S proteasome after immunoprecipitation of VR-EPC membrane extract with CTA 157-2 sepharose beads. Functionally, CTA 157-2 enhanced concentration dependently AMC (7-amino-4-methylcoumarin) cleavage from LLVY (N-Succinyl-Leu-Leu-Val-Tyr) by recombinant 20S proteasome as well as proteasomal activity in VR-EPC extracts. Proliferation of VR-EPCs (BrdU incorporation) was reduced by CTA 157-2. Infusion of the antibody into the collateral circulation reduced number of collateral arteries, collateral proliferation, and collateral conductance in vivo. In conclusion our results indicate that extracellular cell surface bound 20S proteasome influences VR-EPC function in vitro and collateral growth in vivo. PMID:26146628

  12. The ERdj5-Sel1L complex facilitates cholera toxin retrotranslocation

    PubMed Central

    Williams, Jeffrey M.; Inoue, Takamasa; Banks, Lindsey; Tsai, Billy

    2013-01-01

    Cholera toxin (CT) traffics from the host cell surface to the endoplasmic reticulum (ER), where the toxin's catalytic CTA1 subunit retrotranslocates to the cytosol to induce toxicity. In the ER, CT is captured by the E3 ubiquitin ligase Hrd1 via an undefined mechanism to prepare for retrotranslocation. Using loss-of-function and gain-of-function approaches, we demonstrate that the ER-resident factor ERdj5 promotes CTA1 retrotranslocation, in part, via its J domain. This Hsp70 cochaperone regulates binding between CTA and the ER Hsp70 BiP, a chaperone previously implicated in toxin retrotranslocation. Importantly, ERdj5 interacts with the Hrd1 adaptor Sel1L directly through Sel1L's N-terminal lumenal domain, thereby linking ERdj5 to the Hrd1 complex. Sel1L itself also binds CTA and facilitates toxin retrotranslocation. By contrast, EDEM1 and OS-9, two established Sel1L binding partners, do not play significant roles in CTA1 retrotranslocation. Our results thus identify two ER factors that promote ER-to-cytosol transport of CTA1. They also indicate that ERdj5, by binding to Sel1L, triggers BiP–toxin interaction proximal to the Hrd1 complex. We postulate this scenario enables the Hrd1-associated retrotranslocation machinery to capture the toxin efficiently once the toxin is released from BiP. PMID:23363602

  13. False positive computed tomographic angiography for Stanford type A aortic dissection.

    PubMed

    Bandali, Murad F; Hatem, Muhammed A; Appoo, Jehangir J; Hutchison, Stuart J; Wong, Jason K

    2015-12-01

    Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Department bedside ultrasound suggesting an intimal flap in the aorta, CTA was requested to better assess the ascending aorta and was interpreted as consistent with Stanford Type A aortic dissection with thrombosis of the false lumen in the ascending aorta. However, intra-operative imaging (TEE and epi-aortic scanning) did not identify an intimal flap or dissection, and neither did definitive surgical inspection of the aorta. The suspected aortic dissection and thrombosed false lumen were not visualized on repeat CTA two days later. False positive diagnosis of Stanford Type A aortic dissection on CTA can be the result of technical factors, streak artifacts, motion artifacts, and periaortic structures. In this case, non-uniform arterial contrast enhancement secondary to unrecognized biventricular dysfunction resulted in the false positive CTA appearance of an intimal flap and mural thrombus. Intra-operative TEE and epi-aortic scanning were proven correct in excluding aortic dissection by the standard of definitive surgical inspection of the aorta.

  14. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    PubMed

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. The ASTRI mini-array software system (MASS) implementation: a proposal for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Tanci, Claudio; Tosti, Gino; Conforti, Vito; Schwarz, Joseph; Antolini, Elisa; Antonelli, L. A.; Bulgarelli, Andrea; Bigongiari, Ciro; Bruno, Pietro; Canestrari, Rodolfo; Capalbi, Milvia; Cascone, Enrico; Catalano, Osvaldo; Di Paola, Andrea; Di Pierro, Federico; Fioretti, Valentina; Gallozzi, Stefano; Gardiol, Daniele; Gianotti, Fulvio; Giro, Enrico; Grillo, Alessandro; La Palombara, Nicola; Leto, Giuseppe; Lombardi, Saverio; Maccarone, Maria C.; Pareschi, Giovanni; Russo, Federico; Sangiorgi, Pierluca; Scuderi, Salvo; Stringhetti, Luca; Testa, Vincenzo; Trifoglio, Massimo; Vercellone, Stefano; Zoli, Andrea

    2016-08-01

    The ASTRI mini-array, composed of nine small-size dual mirror (SST-2M) telescopes, has been proposed to be installed at the southern site of the Cherenkov Telescope Array (CTA), as a set of preproduction units of the CTA observatory. The ASTRI mini-array is a collaborative and international effort carried out by Italy, Brazil and South Africa and led by the Italian National Institute of Astrophysics, INAF. We present the main features of the current implementation of the Mini-Array Software System (MASS) now in use for the activities of the ASTRI SST-2M telescope prototype located at the INAF observing station on Mt. Etna, Italy and the characteristics that make it a prototype for the CTA control software system. CTA Data Management (CTADATA) and CTA Array Control and Data Acquisition (CTA-ACTL) requirements and guidelines as well as the ASTRI use cases were considered in the MASS design, most of its features are derived from the Atacama Large Millimeter/sub-millimeter Array Control software. The MASS will provide a set of tools to manage all onsite operations of the ASTRI mini-array in order to perform the observations specified in the short term schedule (including monitoring and controlling all the hardware components of each telescope and calibration device), to analyze the acquired data online and to store/retrieve all the data products to/from the onsite repository.

  16. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    PubMed

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  17. Conditioned taste aversion dependent regulation of amygdala gene expression.

    PubMed

    Panguluri, Siva K; Kuwabara, Nobuyuki; Kang, Yi; Cooper, Nigel; Lundy, Robert F

    2012-02-28

    The present experiments investigated gene expression in the amygdala following contingent taste/LiCl treatment that supports development of conditioned taste aversion (CTA). The use of whole genome chips and stringent data set filtering led to the identification of 168 genes regulated by CTA compared to non-contingent LiCl treatment that does not support CTA learning. Seventy-six of these genes were eligible for network analysis. Such analysis identified "behavior" as the top biological function, which was represented by 15 of the 76 genes. These genes included several neuropeptides, G protein-coupled receptors, ion channels, kinases, and phosphatases. Subsequent qRT-PCR analyses confirmed changes in mRNA expression for 5 of 7 selected genes. We were able to demonstrate directionally consistent changes in protein level for 3 of these genes; insulin 1, oxytocin, and major histocompatibility complex class I-C. Behavioral analyses demonstrated that blockade of central insulin receptors produced a weaker CTA that was less resistant to extinction. Together, these results support the notion that we have identified downstream genes in the amygdala that contribute to CTA learning. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. 17 CFR 240.17Ad-10 - Prompt posting of certificate detail to master securityholder files, maintenance of accurate...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... between co-transfer agents and recordkeeping transfer agents, maintenance of current control book... securityholder files, maintenance of accurate securityholder files, communications between co-transfer agents and recordkeeping transfer agents, maintenance of current control book, retention of certificate detail and “buy-in...

  19. 17 CFR 240.17Ad-10 - Prompt posting of certificate detail to master securityholder files, maintenance of accurate...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... between co-transfer agents and recordkeeping transfer agents, maintenance of current control book... securityholder files, maintenance of accurate securityholder files, communications between co-transfer agents and recordkeeping transfer agents, maintenance of current control book, retention of certificate detail and “buy-in...

  20. 17 CFR 240.17Ad-10 - Prompt posting of certificate detail to master securityholder files, maintenance of accurate...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... between co-transfer agents and recordkeeping transfer agents, maintenance of current control book... securityholder files, maintenance of accurate securityholder files, communications between co-transfer agents and recordkeeping transfer agents, maintenance of current control book, retention of certificate detail and “buy-in...

  1. Cholinergic dependence of taste memory formation: evidence of two distinct processes.

    PubMed

    Gutiérrez, Ranier; Rodriguez-Ortiz, Carlos J; De La Cruz, Vanesa; Núñez-Jaramillo, Luis; Bermudez-Rattoni, Federico

    2003-11-01

    Learning the aversive or positive consequences associated with novel taste solutions has a strong significance for an animal's survival. A lack of recognition of a taste's consequences could prevent ingestion of potential edibles or encounter death. We used conditioned taste aversion (CTA) and attenuation of neophobia (AN) to study aversive and safe taste memory formation. To determine if muscarinic receptors in the insular cortex participate differentially in both tasks, we infused the muscarinic antagonists scopolamine at distinct times before or after the presentation of a strong concentration of saccharin, followed by either an i.p. injection of a malaise-inducing agent or no injection. Our results showed that blockade of muscarinic receptors before taste presentation disrupts both learning tasks. However, the same treatment after the taste prevents AN but not CTA. These results clearly demonstrate that cortical cholinergic activity participates in the acquisition of both safe and aversive memory formation, and that cortical muscarinic receptors seem to be necessary for safe but not for aversive taste memory consolidation. These results suggest that the taste memory trace is processed in the insular cortex simultaneously by at least two independent mechanisms, and that their interaction would determine the degree of aversion or preference learned to a novel taste.

  2. Bacteroides Fragilis OmpA: Utility as a Live Vaccine Vector for Biodefense Agents

    DTIC Science & Technology

    2009-01-01

    shared by all four homologs are highlighted in black. Positions where amino acid similarity is shared by all four homologs are highlighted in gray ...study Primers for RT PCR OmpA1-F gga tat gac ggt gtt gcc ag this study OmpA1-R tag cag cag cca tgt cat tc this study OmpA2-F tag aag gtg cat...gga cta ct this study OmpA2-R aac cgc caa tag cat tgg ac this study OmpA3-F act ccg ctg atc aat gtg tc this study OmpA3-R cgt ctg cac gca tag tga ag

  3. The Effectiveness of a Cognitive Task Analysis Informed Curriculum to Increase Self-Efficacy and Improve Performance for an Open Cricothyrotomy

    DTIC Science & Technology

    2011-01-01

    either the CTA group (n 12) or the control group (n 14). The CTA group learned the open cricothyrotomy procedure using the CTA curriculum. The...completed a 6-item pretest that posed open - ended questions regarding actions and decisions required to conduct the procedure given a specific... posttest assessing their knowl- edge of the procedure. Parallel forms of the pretest and post- test instruments were developed using different case scenar

  4. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.

    PubMed

    Törnqvist, P; Dias, N; Sonesson, B; Kristmundsson, T; Resch, T

    2015-04-01

    Re-interventions after endovascular abdominal aortic aneurysm repair (EVAR) are common and therefore a strict imaging follow up protocol is required. The purpose of this study was to evaluate whether cone beam computed tomography (CBCT) can detect intra-operative complications and to compare this with angiography and the 1 month CT follow up (computed tomography angiography [CTA]). Fifty-one patients (44 men) were enrolled in a prospective trial. Patients underwent completion angiography and CBCT during infrarenal EVAR. Contrast was used except when pre-operative renal insufficiency was present or if the maximum contrast dose threshold was reached. CBCT reconstruction included the top of the stent graft to the iliac bifurcation. Endoleaks, kinks, or compressions were recorded. CBCT was technically successful in all patients. Twelve endoleaks were detected on completion digital subtraction angiography (CA). CBCT detected 4/5 type 1 endoleaks, but only one type 2 endoleak. CTA identified eight type 2 endoleaks and one residual type I endoleak. Two cases of stent compression were seen on CA. CBCT revealed five stent compressions and one kink, which resulted in four intra-operative adjunctive manoeuvres. CTA identified all cases of kinks or compressions that were left untreated. Two of them were corrected later. No additional kinks/compressions were found on CTA. Groin closure consisted of 78 fascia sutures, nine cut downs, and 11 percutaneous sutures. Seven femoral artery pseudoaneurysms (<1 cm) were detected on CTA, but no intervention was needed. CA is better than CBCT in detecting and categorizing endoleaks but CBCT (with or without contrast) is better than CA for detection of kinks or stentgraft compression. CTA plus CBCT identified all significant complications noted on the 1 month follow up CTA. The use of intra-operative CA and CBCT could replace early CTA after standard EVAR thus reducing overall radiation and contrast use. Technical development might further improve the resolution and usefulness of CBCT. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFR(CT): outcome and resource impacts study.

    PubMed

    Douglas, Pamela S; Pontone, Gianluca; Hlatky, Mark A; Patel, Manesh R; Norgaard, Bjarne L; Byrne, Robert A; Curzen, Nick; Purcell, Ian; Gutberlet, Matthias; Rioufol, Gilles; Hink, Ulrich; Schuchlenz, Herwig Walter; Feuchtner, Gudrun; Gilard, Martine; Andreini, Daniele; Jensen, Jesper M; Hadamitzky, Martin; Chiswell, Karen; Cyr, Derek; Wilk, Alan; Wang, Furong; Rogers, Campbell; De Bruyne, Bernard

    2015-12-14

    In symptomatic patients with suspected coronary artery disease (CAD), computed tomographic angiography (CTA) improves patient selection for invasive coronary angiography (ICA) compared with functional testing. The impact of measuring fractional flow reserve by CTA (FFRCT) is unknown. At 11 sites, 584 patients with new onset chest pain were prospectively assigned to receive either usual testing (n = 287) or CTA/FFR(CT) (n = 297). Test interpretation and care decisions were made by the clinical care team. The primary endpoint was the percentage of those with planned ICA in whom no significant obstructive CAD (no stenosis ≥50% by core laboratory quantitative analysis or invasive FFR < 0.80) was found at ICA within 90 days. Secondary endpoints including death, myocardial infarction, and unplanned revascularization were independently and blindly adjudicated. Subjects averaged 61 ± 11 years of age, 40% were female, and the mean pre-test probability of obstructive CAD was 49 ± 17%. Among those with intended ICA (FFR(CT)-guided = 193; usual care = 187), no obstructive CAD was found at ICA in 24 (12%) in the CTA/FFR(CT) arm and 137 (73%) in the usual care arm (risk difference 61%, 95% confidence interval 53-69, P< 0.0001), with similar mean cumulative radiation exposure (9.9 vs. 9.4 mSv, P = 0.20). Invasive coronary angiography was cancelled in 61% after receiving CTA/FFR(CT) results. Among those with intended non-invasive testing, the rates of finding no obstructive CAD at ICA were 13% (CTA/FFR(CT)) and 6% (usual care; P = 0.95). Clinical event rates within 90 days were low in usual care and CTA/FFR(CT) arms. Computed tomographic angiography/fractional flow reserve by CTA was a feasible and safe alternative to ICA and was associated with a significantly lower rate of invasive angiography showing no obstructive CAD. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  6. Role for the Rostromedial Tegmental Nucleus in Signaling the Aversive Properties of Alcohol.

    PubMed

    Glover, Elizabeth J; McDougle, Molly J; Siegel, Griffin S; Jhou, Thomas C; Chandler, L Judson

    2016-08-01

    While the rewarding effects of alcohol contribute significantly to its addictive potential, it is becoming increasingly appreciated that alcohol's aversive properties also play an important role in the propensity to drink. Despite this, the neurobiological mechanism for alcohol's aversive actions is not well understood. The rostromedial tegmental nucleus (RMTg) was recently characterized for its involvement in aversive signaling and has been shown to encode the aversive properties of cocaine, yet its involvement in alcohol's aversive actions have not been elucidated. Adult male and female Long-Evans rats underwent conditioned taste aversion (CTA) procedures where exposure to a novel saccharin solution was paired with intraperitoneal administration of saline, lithium chloride (LiCl), or ethanol (EtOH). Control rats underwent the same paradigm except that drug and saccharin exposure were explicitly unpaired. Saccharin consumption was measured on test day in the absence of drug administration, and rats were sacrificed 90 to 105 minutes following access to saccharin. Brains were subsequently harvested and processed for cFos immunohistochemistry. The number of cFos-labeled neurons was counted in the RMTg and the lateral habenula (LHb)-a region that sends prominent glutamatergic input to the RMTg. In rats that received paired drug and saccharin exposure, EtOH and LiCl induced significant CTA compared to saline to a similar degree in males and females. Both EtOH- and LiCl-induced CTA significantly enhanced cFos expression in the RMTg and LHb but not the hippocampus. Similar to behavioral measures, no significant effect of sex on CTA-induced cFos expression was observed. cFos expression in both the RMTg and LHb was significantly correlated with CTA magnitude with greater cFos being associated with more pronounced CTA. In addition, cFos expression in the RMTg was positively correlated with LHb cFos. These data suggest that the RMTg and LHb are involved in the expression of CTA and are consistent with previous work implicating the RMTg in aversive signaling. Furthermore, increased cFos expression in the RMTg following EtOH-induced CTA suggests that this region plays a role in signaling alcohol's aversive properties. Copyright © 2016 by the Research Society on Alcoholism.

  7. The Cherenkov Telescope Array Observatory: top level use cases

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Kosack, K.; Hinton, J.; Tosti, G.; Schwanke, U.; Schwarz, J.; Colomé, P.; Conforti, V.; Khelifi, B.; Goullon, J.; Ong, R.; Markoff, S.; Contreras, J. L.; Lucarelli, F.; Antonelli, L. A.; Bigongiari, C.; Boisson, C.; Bosnjak, Z.; Brau-Nogué, S.; Carosi, A.; Chen, A.; Cotter, G.; Covino, S.; Daniel, M.; De Cesare, G.; de Ona Wilhelmi, E.; Della Volpe, M.; Di Pierro, F.; Fioretti, V.; Füßling, M.; Garczarczyk, M.; Gaug, M.; Glicenstein, J. F.; Goldoni, P.; Götz, D.; Grandi, P.; Heller, M.; Hermann, G.; Inoue, S.; Knödlseder, J.; Lenain, J.-P.; Lindfors, E.; Lombardi, S.; Luque-Escamilla, P.; Maier, G.; Marisaldi, M.; Mundell, C.; Neyroud, N.; Noda, K.; O'Brien, P.; Petrucci, P. O.; Martí Ribas, J.; Ribó, M.; Rodriguez, J.; Romano, P.; Schmid, J.; Serre, N.; Sol, H.; Schussler, F.; Stamerra, A.; Stolarczyk, T.; Vandenbrouck, J.; Vercellone, S.; Vergani, S.; Zech, A.; Zoli, A.

    2016-08-01

    Today the scientific community is facing an increasing complexity of the scientific projects, from both a technological and a management point of view. The reason for this is in the advance of science itself, where new experiments with unprecedented levels of accuracy, precision and coverage (time and spatial) are realised. Astronomy is one of the fields of the physical sciences where a strong interaction between the scientists, the instrument and software developers is necessary to achieve the goals of any Big Science Project. The Cherenkov Telescope Array (CTA) will be the largest ground-based very high-energy gamma-ray observatory of the next decades. To achieve the full potential of the CTA Observatory, the system must be put into place to enable users to operate the telescopes productively. The software will cover all stages of the CTA system, from the preparation of the observing proposals to the final data reduction, and must also fit into the overall system. Scientists, engineers, operators and others will use the system to operate the Observatory, hence they should be involved in the design process from the beginning. We have organised a workgroup and a workflow for the definition of the CTA Top Level Use Cases in the context of the Requirement Management activities of the CTA Observatory. Scientists, instrument and software developers are collaborating and sharing information to provide a common and general understanding of the Observatory from a functional point of view. Scientists that will use the CTA Observatory will provide mainly Science Driven Use Cases, whereas software engineers will subsequently provide more detailed Use Cases, comments and feedbacks. The main purposes are to define observing modes and strategies, and to provide a framework for the flow down of the Use Cases and requirements to check missing requirements and the already developed Use-Case models at CTA sub-system level. Use Cases will also provide the basis for the definition of the Acceptance Test Plan for the validation of the overall CTA system. In this contribution we present the organisation and the workflow of the Top Level Use Cases workgroup.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larsen, Michael B.; Van Horn, J. David; Wu, Fei

    The synthesis of microporous polymers generally requires postpolymerization modification via hyper-cross-linking to trap the polymeric network in a state with high void volume. An alternative approach utilizes rigid, sterically demanding monomers to inhibit efficient packing, thus leading to a high degree of free volume between polymer side groups and main chains. Herein we combine polymers of intrinsic microporosity with polymerization-induced microphase separation (PIMS), a versatile methodology for the synthesis of nanostructured materials that can be rendered mesoporous. Copolymerization of various styrenic monomers with divinylbenzene in the presence of a poly(lactide) terminated with a chain-transfer agent (PLA-CTA) results in kinetic trappingmore » of a microphase-separated state. Subsequent etching of PLA provides a bicontinuous mesoporous network. Using equilibrium and kinetic nitrogen sorption experiments as well as positron annihilation lifetime spectroscopy (PALS), we demonstrate that variations in the steric characteristics of the styrenic monomer impart the network with microporosity, resulting in hierarchically (meso and micro) porous materials. Additionally, structure–property relationships of the styrenic monomer with total surface area and pore volume indicate that the glass transition temperature (Tg) of the corresponding styrenic homopolymers provides a reasonable measure of the steric interactions and resultant microporosity in these systems. Finally, PALS provides insight into micro- and mesoscopic void volume differences between porous monoliths containing either tert-butyl or TMS-modified styrenic monomers compared to the parent, unmodified styrene.« less

  9. Overlapping memory trace indispensable for linking, but not recalling, individual memories.

    PubMed

    Yokose, Jun; Okubo-Suzuki, Reiko; Nomoto, Masanori; Ohkawa, Noriaki; Nishizono, Hirofumi; Suzuki, Akinobu; Matsuo, Mina; Tsujimura, Shuhei; Takahashi, Yukari; Nagase, Masashi; Watabe, Ayako M; Sasahara, Masakiyo; Kato, Fusao; Inokuchi, Kaoru

    2017-01-27

    Memories are not stored in isolation from other memories but are integrated into associative networks. However, the mechanisms underlying memory association remain elusive. Using two amygdala-dependent behavioral paradigms-conditioned taste aversion (CTA) and auditory-cued fear conditioning (AFC)-in mice, we found that presenting the conditioned stimulus used for the CTA task triggered the conditioned response of the AFC task after natural coreactivation of the memories. This was accompanied through an increase in the overlapping neuronal ensemble in the basolateral amygdala. Silencing of the overlapping ensemble suppressed CTA retrieval-induced freezing. However, retrieval of the original CTA or AFC memory was not affected. A small population of coshared neurons thus mediates the link between memories. They are not necessary for recalling individual memories. Copyright © 2017, American Association for the Advancement of Science.

  10. Strategies for the follow-up of gravitational wave transients with the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Bartos, I.; Di Girolamo, T.; Gair, J. R.; Hendry, M.; Heng, I. S.; Humensky, T. B.; Márka, S.; Márka, Z.; Messenger, C.; Mukherjee, R.; Nieto, D.; O'Brien, P.; Santander, M.

    2018-06-01

    The observation of the electromagnetic counterpart of gravitational-wave (GW) transient GW170817 demonstrated the potential in extracting astrophysical information from multimessenger discoveries. The forthcoming deployment of the first telescopes of the Cherenkov Telescope Array (CTA) observatory will coincide with Advanced LIGO/Virgo's next observing run, O3, enabling the monitoring of gamma-ray emission at E > 20 GeV, and thus particle acceleration, from GW sources. CTA will not be greatly limited by the precision of GW localization as it will be capable of rapidly covering the GW error region with sufficient sensitivity. We examine the current status of GW searches and their follow-up effort, as well as the status of CTA, in order to identify some of the general strategies that will enhance CTA's contribution to multimessenger discoveries.

  11. Simulated gamma-ray pulse profile of the Crab pulsar with the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Burtovoi, A.; Zampieri, L.

    2016-07-01

    We present simulations of the very high energy (VHE) gamma-ray light curve of the Crab pulsar as observed by the Cherenkov Telescope Array (CTA). The CTA pulse profile of the Crab pulsar is simulated with the specific goal of determining the accuracy of the position of the interpulse. We fit the pulse shape obtained by the Major Atmospheric Gamma-Ray Imaging Cherenkov (MAGIC) telescope with a three-Gaussian template and rescale it to account for the different CTA instrumental and observational configurations. Simulations are performed for different configurations of CTA and for the ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) mini-array. The northern CTA configuration will provide an improvement of a factor of ˜3 in accuracy with an observing time comparable to that of MAGIC (73 h). Unless the VHE spectrum above 1 TeV behaves differently from what we presently know, unreasonably long observing times are required for a significant detection of the pulsations of the Crab pulsar with the high-energy-range sub-arrays. We also found that an independent VHE timing analysis is feasible with Large Size Telescopes. CTA will provide a significant improvement in determining the VHE pulse shape parameters necessary to constrain theoretical models of the gamma-ray emission of the Crab pulsar. One of such parameters is the shift in phase between peaks in the pulse profile at VHE and in other energy bands that, if detected, may point to different locations of the emission regions.

  12. A novel non-toxic combined CTA1-DD and ISCOMS adjuvant vector for effective mucosal immunization against influenza virus.

    PubMed

    Eliasson, Dubravka Grdic; Helgeby, Anja; Schön, Karin; Nygren, Caroline; El-Bakkouri, Karim; Fiers, Walter; Saelens, Xavier; Lövgren, Karin Bengtsson; Nyström, Ida; Lycke, Nils Y

    2011-05-23

    Here we demonstrate that by using non-toxic fractions of saponin combined with CTA1-DD we can achieve a safe and above all highly efficacious mucosal adjuvant vector. We optimized the construction, tested the requirements for function and evaluated proof-of-concept in an influenza A virus challenge model. We demonstrated that the CTA1-3M2e-DD/ISCOMS vector provided 100% protection against mortality and greatly reduced morbidity in the mouse model. The immunogenicity of the vector was superior to other vaccine formulations using the ISCOM or CTA1-DD adjuvants alone. The versatility of the vector was best exemplified by the many options to insert, incorporate or admix vaccine antigens with the vector. Furthermore, the CTA1-3M2e-DD/ISCOMS could be kept 1 year at 4°C or as a freeze-dried powder without affecting immunogenicity or adjuvanticity of the vector. Strong serum IgG and mucosal IgA responses were elicited and CD4 T cell responses were greatly enhanced after intranasal administration of the combined vector. Together these findings hold promise for the combined vector as a mucosal vaccine against influenza virus infections including pandemic influenza. The CTA1-DD/ISCOMS technology represents a breakthrough in mucosal vaccine vector design which successfully combines immunomodulation and targeting in a safe and stable particulate formation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    PubMed

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  14. Ruptured Distal Posterior Inferior Cerebellar Artery (PICA) Aneurysms Associated with Cerebellar Arterial Venous Malformations (AVMs): A Case Series and Review of the Literature Demonstrating the Need for Angiographic Evaluation and Feasibility of Endovascular Treatment.

    PubMed

    Case, David; Kumpe, David; Cava, Luis; Neumann, Robert; White, Andrew; Roark, Christopher; Seinfeld, Joshua

    2017-01-01

    The characteristics, diagnosis, and preferred management strategies for distal posterior inferior cerebellar artery (PICA) aneurysms associated with cerebellar arteriovenous malformation (AVMs) are poorly understood. We present a case series with attention to aneurysm angioarchitecture, diagnostic imaging, treatment approaches, and a thorough review of the literature. With this information, we demonstrate a specific anatomical pattern for these aneurysms, an underreported need for conventional digital subtraction angiography (DSA) during evaluation, along with the utility of endovascular treatment with liquid embolic agents. Neurosurgical patients from 2005 to 2016 were reviewed to identify PICA aneurysms along with distal PICA aneurysms. Details of their presentation, imaging studies, associated AVMs and treatment were recorded. A thorough literature search of previous case series and case reports of distal PICA aneurysms with and without associated small cerebellar AVMs was performed with PubMed and Google Scholar. Thirty-four patients with PICA aneurysms were identified at our institution, 12 of which were in a distal segment. All 12 of these patients underwent DSA as a part of their evaluation. Of the 12 patients with distal PICA aneurysms, 9 presented with subarachnoid hemorrhage and intraventricular hemorrhage. Five of these patients had a small occult cerebellar AVM. All nine patients presenting with a ruptured distal PICA aneurysm had a Fischer grade 4 subarachnoid hemorrhage. Of the five patients with a small occult cerebellar AVM, the AVM nidus was missed on computed tomography angiogram (CTA) interpretation but easily visualized with DSA. CTA followed by DSA with concurrent endovascular treatment was performed in 9 of the 12 patients with distal PICA aneurysms. Two of the 12 patients were treated with microsurgical clip ligation, and one mycotic aneurysm was identified and treated with antibiotics. Parent vessel sacrifice was used distal to the aneurysm in all 5 associated AVM cases with liquid embolic agents as well as AVM embolization in 3 of the 5 cases. Fifty-one well-described case reports of distal PICA aneurysms associated with small cerebellar AVMs have been reported in the literature. A total of 12 well-described case series of distal PICA aneurysms that comment on associated AVMs describe an associated small cerebellar AVM incidence of 4%-50%. In our case series, the incidence of an associated small cerebellar AVM with a distal PICA aneurysm was 42%. In cases of distal PICA aneurysms, there is a frequent association of a small cerebellar AVM. In our series, CTA was an inadequate diagnostic study to identify the associated AVM, and DSA was necessary to definitely visualize the AVM nidus. Endovascular treatment of the aneurysm and AVM with the use of liquid embolic agents was a feasible and useful management strategy. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The ASTRI/CTA mini-array software system

    NASA Astrophysics Data System (ADS)

    Tosti, Gino; Schwarz, Joseph; Antonelli, Lucio Angelo; Trifoglio, Massimo; Catalano, Osvaldo; Maccarone, Maria Concetta; Leto, Giuseppe; Gianotti, Fulvio; Canestrari, Rodolfo; Giro, Enrico; Fiorini, Mauro; La Palombara, Nicola; Pareschi, Giovanni; Stringhetti, Luca; Vercellone, Stefano; Conforti, Vito; Tanci, Claudio; Bruno, Pietro; Grillo, Alessandro; Testa, Vincenzo; di Paola, Andrea; Gallozzi, Stefano

    2014-07-01

    ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is a Flagship Project financed by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. The main goals of the ASTRI project are the realization of an end-to-end prototype of a Small Size Telescope (SST) for the Cherenkov Telescope Array (CTA) in a dual- mirror configuration (SST-2M) and, subsequently, of a mini-array comprising seven SST-2M telescopes. The mini-array will be placed at the final CTA Southern Site, which will be part of the CTA seed array, around which the whole CTA observatory will be developed. The Mini-Array Software System (MASS) will provide a comprehensive set of tools to prepare an observing proposal, to perform the observations specified therein (monitoring and controlling all the hardware components of each telescope), to analyze the acquired data online and to store/retrieve all the data products to/from the archive. Here we present the main features of the MASS and its first version, to be tested on the ASTRI SST-2M prototype that will be installed at the INAF observing station located at Serra La Nave on Mount Etna in Sicily.

  16. The role of computed tomography in detecting splenic arteriovenous fistula and concomitant atrial myxoma.

    PubMed

    Rroji, Arben; Bilaj, Fatmir; Qirinxhi, Denis; Vucini, Ortencia; Hasimi, Endri; Goda, Artan

    2014-01-01

    Female, 45 FINAL DIAGNOSIS: Arterio-venous fistula of the splean Symptoms: Lef-side abdominal pain Medication: - Clinical Procedure: - Specialty: Surgery. Rare disease. Splenic arterial-venous fistula and atrial myxoma are not rare cases but the co-existence of both lesions in the same patient is unpublished so far. A 45- year-old woman presented with vague left flank pain. She was initially scanned by B-dimensional echography, which revealed multiple enlarged hypo-echoic lesions in the splenic hilum. To further characterize the lesion, we performed computed tomography angiography (CTA). CTA showed dilatation of the splenic artery, and aneurismal dilatation of the splenic vein, associated with early opacification of the portal system. CTA showed also an intrasplenic venous aneurism, which was presumed to be the site of fistulous communication. Celiac arteriography confirmed the CTA findings. A left atrial mass was detected by cardiac echography, which was evaluated better by CTA, and was consistent with atrial myxoma. The patient underwent open surgery in different stage with resection of the atrial mass and spleen. The postoperative period was uneventful. This is a unique case in the literature, showing the coexistence of a dual-pathology splenic arterial venous fistula and atrial myxoma.

  17. Blind consent? A social psychological investigation of non-readership of click-through agreements.

    PubMed

    Plaut, Victoria C; Bartlett, Robert P

    2012-08-01

    Across two studies we aimed to measure empirically the extent of non-readership of click-through agreements (CTAs), identify the dominant beliefs about CTAs contributing to non-readership, and experimentally manipulate these beliefs to decrease automatic non-reading behavior and enhance contract efficiency. In our initial questionnaire study (Study 1), as predicted, the vast majority of participants reported not reading CTAs and the most prevalent beliefs about CTAs contributing to non-readership included: they are too long and time-consuming, they are all the same, they give one no choice but to agree, they are irrelevant, and vendors are generally reputable. Manipulating these beliefs on a simulated music website (Study 2) revealed an increase in readership. In addition, CTA comprehension and CTA rejection rates were both increased significantly by manipulating the length of the CTA. These results demonstrate support for the influence of widely held beliefs about CTAs on contract readership, provide evidence against the common "limited cognition" perspective on non-readership, and suggest that presenting CTAs in a short, readable format can increase CTA readership and comprehension as well as shopping of CTA terms. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  18. Duplex Ultrasonography Has Limited Utility in Detection of Postoperative DVT After Primary Total Joint Arthroplasty.

    PubMed

    Vira, Shaleen; Ramme, Austin J; Alaia, Michael J; Steiger, David; Vigdorchik, Jonathan M; Jaffe, Frederick

    2016-07-01

    Duplex ultrasound is routinely used to evaluate suspected deep venous thrombosis after total joint arthroplasty. When there is a clinical suspicion for a pulmonary embolism, a chest angiogram (chest CTA) is concomitantly obtained. Two questions were addressed: First, for the population of patients who receive duplex ultrasound after total joint arthroplasty, what is the rate of positive results? Second, for these patients, how many of these also undergo chest CTA for clinical suspicion of pulmonary embolus and how many of these tests are positive? Furthermore, what is the correlation between duplex ultrasound results and chest CTA results? A retrospective chart review was conducted of total joint replacement patients in 2011 at a single institution. Inclusion criteria were adult patients who underwent a postoperative duplex ultrasonography for clinical suspicion of deep venous thrombosis (DVT). Demographic data, result of duplex scan, clinical indications for obtaining the duplex scan, and DVT prophylaxis used were recorded. Additionally, if a chest CTA was obtained for clinical suspicion for pulmonary embolus, results and clinical indication for obtaining the test were recorded. The rate of positive results for duplex ultrasonography and chest CTA was computed and correlated based on clinical indications. Two hundred ninety-five patients underwent duplex ultrasonography of which only 0.7% were positive for a DVT. One hundred three patients underwent a chest CTA for clinical suspicion of a pulmonary embolism (PE) of which 26 revealed a pulmonary embolus, none of which had a positive duplex ultrasound. Postoperative duplex scans have a low rate of positive results. A substantial number of patients with negative duplex results subsequently underwent chest CTA for clinical suspicion for which a pulmonary embolus was found, presumably resulting from a DVT despite negative duplex ultrasound result. A negative duplex ultrasonography should not rule out the presence of a DVT which can embolize to the lungs and thus should not preclude further workup when clinical suspicion exists for a pulmonary embolus.

  19. CTA1-DD adjuvant promotes strong immunity against human immunodeficiency virus type 1 envelope glycoproteins following mucosal immunization.

    PubMed

    Sundling, Christopher; Schön, Karin; Mörner, Andreas; Forsell, Mattias N E; Wyatt, Richard T; Thorstensson, Rigmor; Karlsson Hedestam, Gunilla B; Lycke, Nils Y

    2008-12-01

    Strategies to induce potent and broad antibody responses against the human immunodeficiency virus type 1 (HIV-1) envelope glycoproteins (Env) at both systemic and mucosal sites represent a central goal for HIV-1 vaccine development. Here, we show that the non-toxic CTA1-DD adjuvant promoted mucosal and systemic humoral and cell-mediated immune responses following intranasal (i.n.) immunizations with trimeric or monomeric forms of HIV-1 Env in mice and in non-human primates. Env-specific IgG subclasses in the serum of immunized mice reflected a balanced Th1/Th2 type of response. Strikingly, i.n. immunizations with Env and the CTA1-DD adjuvant induced substantial levels of mucosal anti-Env IgA in bronchial alveolar lavage and also detectable levels in vaginal secretions. By contrast, parenteral immunizations of Env formulated in Ribi did not stimulate mucosal IgA responses, while the two adjuvants induced a similar distribution of Env-specific IgG-subclasses in serum. A single parenteral boost with Env in Ribi adjuvant into mice previously primed i.n. with Env and CTA1-DD, augmented the serum anti-Env IgG levels to similar magnitudes as those observed after three intraperitoneal immunizations with Env in Ribi. The augmenting potency of CTA1-DD was similar to that of LTK63 or CpG oligodeoxynucleotides (ODN). However, in contrast to CpG ODN, the effect of CTA1-DD and LTK63 appeared to be independent of MyD88 and toll-like receptor signalling. This is the first demonstration that CTA1-DD augments specific immune responses also in non-human primates, suggesting that this adjuvant could be explored further as a clinically safe mucosal vaccine adjuvant for humoral and cell-mediated immunity against HIV-1 Env.

  20. Fourth update on CT angiography of coronary stents: in vitro evaluation of 24 novel stent types.

    PubMed

    Hickethier, Tilman; Wenning, Justus; Doerner, Jonas; Maintz, David; Michels, Guido; Bunck, Alexander C

    2017-01-01

    Background Non-invasive evaluation of coronary stent patency by coronary computed tomography angiography (cCTA) remains challenging. Multiple studies showed that CT technology but also individual stent design strongly influence the assessability of coronary stents by cCTA. Purpose To expand the available data on cCTA characteristics of coronary stents by 24 novel types to help interpreting examinations of patients after stent placement and selecting which stents are suitable for assessment by cCTA. Material and Methods Twenty-four novel coronary stents (17 cobalt-chromium, six stainless-steel, one platinum-chromium) were examined in a coronary phantom. Standard cCTA parameters with stent-specific algorithms were used. Image quality was quantified for each stent using established parameters (in-stent attenuation alteration and visible lumen diameter). Results Most stents (n = 14) showed lumen visibilities of 45-55%. No severe restriction of lumen visibility (>60%) was found. The majority of stents (n = 13) caused only small intraluminal attenuation deviations and no severe alterations (>20%) were found. When grouped by manufacturing material, no significant differences were found between cobalt-chromium and stainless-steel with identical mean visible diameters (1.52 ± 0.17 mm vs. 1.52 ± 0.13 mm) and comparable attenuation alterations (35.04 ± 16.56 HU vs. 21.25 ± 14.60 HU). The only platinum-chromium stent showed a smaller visible diameter (1.23 mm) and higher attenuation alteration (41.70 HU), but was also deemed to be assessable by cCTA. Conclusion All 24 novel evaluated stents are eligible for non-invasive evaluation by cCTA without significant differences between cobalt-chromium and stainless-steel stents. This updated catalogue of CT appearances of current coronary stents may serve as reference when taking care of patients with stents in need of coronary imaging.

  1. Diagnostic accuracy of semi-automatic quantitative metrics as an alternative to expert reading of CT myocardial perfusion in the CORE320 study.

    PubMed

    Ostovaneh, Mohammad R; Vavere, Andrea L; Mehra, Vishal C; Kofoed, Klaus F; Matheson, Matthew B; Arbab-Zadeh, Armin; Fujisawa, Yasuko; Schuijf, Joanne D; Rochitte, Carlos E; Scholte, Arthur J; Kitagawa, Kakuya; Dewey, Marc; Cox, Christopher; DiCarli, Marcelo F; George, Richard T; Lima, Joao A C

    To determine the diagnostic accuracy of semi-automatic quantitative metrics compared to expert reading for interpretation of computed tomography perfusion (CTP) imaging. The CORE320 multicenter diagnostic accuracy clinical study enrolled patients between 45 and 85 years of age who were clinically referred for invasive coronary angiography (ICA). Computed tomography angiography (CTA), CTP, single photon emission computed tomography (SPECT), and ICA images were interpreted manually in blinded core laboratories by two experienced readers. Additionally, eight quantitative CTP metrics as continuous values were computed semi-automatically from myocardial and blood attenuation and were combined using logistic regression to derive a final quantitative CTP metric score. For the reference standard, hemodynamically significant coronary artery disease (CAD) was defined as a quantitative ICA stenosis of 50% or greater and a corresponding perfusion defect by SPECT. Diagnostic accuracy was determined by area under the receiver operating characteristic curve (AUC). Of the total 377 included patients, 66% were male, median age was 62 (IQR: 56, 68) years, and 27% had prior myocardial infarction. In patient based analysis, the AUC (95% CI) for combined CTA-CTP expert reading and combined CTA-CTP semi-automatic quantitative metrics was 0.87(0.84-0.91) and 0.86 (0.83-0.9), respectively. In vessel based analyses the AUC's were 0.85 (0.82-0.88) and 0.84 (0.81-0.87), respectively. No significant difference in AUC was found between combined CTA-CTP expert reading and CTA-CTP semi-automatic quantitative metrics in patient based or vessel based analyses(p > 0.05 for all). Combined CTA-CTP semi-automatic quantitative metrics is as accurate as CTA-CTP expert reading to detect hemodynamically significant CAD. Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  2. Comparison of Spot Sign, Blend Sign and Black Hole Sign for Outcome Prediction in Patients with Intracerebral Hemorrhage

    PubMed Central

    Sporns, Peter B.; Schwake, Michael; Kemmling, André; Minnerup, Jens; Schwindt, Wolfram; Niederstadt, Thomas; Schmidt, Rene; Hanning, Uta

    2017-01-01

    Background and Purpose Blend sign (BS) and black hole sign (BHS) on non-contrast computed tomography (NCCT) and spot sign (SS) on CT-angiography (CTA) are indicators of early hematoma expansion in spontaneous intracerebral hemorrhage (ICH). However, their independent contributions to outcome have not been well explored. Methods In this retrospective study, inclusion criteria were: 1) spontaneous ICH and 2) NCCT and CTA performed on admission within 6 hours after onset of symptoms. Discharge outcome was dichotomized as good (modified Rankin Scale [mRS] 0-3) and poor (mRS 4-6) outcomes. The impacts of BHS, BS and SS on outcome were assessed in univariate and multivariable logistic regression models. Results Of 182 patients with spontaneous ICH, 26 (14.3%) presented with BHS, 37 (20.3%) with BS and 39 (21.4%) with SS. There was a substantial correlation between SS and BS (κ=0.701) and a moderate correlation between SS and BHS (κ=0.424). In univariable logistic regression, higher baseline hematoma volume (P<0.001), intraventricular hemorrhage (P=0.002) and the presence of BHS/BS/SS (all P<0.001) on admission CT scan were associated with poor outcome. Multivariable analysis identified intraventricular haemorrhage (odds ratio [OR] 2.22 per mL, P=0.022), baseline hematoma volume (OR 1.03 per mL, P<0.001) and SS on CTA (OR 11.43, P<0.001) as independent predictors of poor outcome, showing that SS compared to BS and BHS was more powerful to predict poor outcome. Conclusions The NCCT BHS and BS are correlated with the CTA SS and are reliable predictors of poor outcome in patients with ICH. Of the CT variables indicating early hematoma expansion, SS on CTA was the most reliable outcome predictor. However, given their correlation with SS on CTA, BS and BHS on NCCT can be useful for predicting outcome if CTA is not obtainable. PMID:29037015

  3. Comparison of Spot Sign, Blend Sign and Black Hole Sign for Outcome Prediction in Patients with Intracerebral Hemorrhage.

    PubMed

    Sporns, Peter B; Schwake, Michael; Kemmling, André; Minnerup, Jens; Schwindt, Wolfram; Niederstadt, Thomas; Schmidt, Rene; Hanning, Uta

    2017-09-01

    Blend sign (BS) and black hole sign (BHS) on non-contrast computed tomography (NCCT) and spot sign (SS) on CT-angiography (CTA) are indicators of early hematoma expansion in spontaneous intracerebral hemorrhage (ICH). However, their independent contributions to outcome have not been well explored. In this retrospective study, inclusion criteria were: 1) spontaneous ICH and 2) NCCT and CTA performed on admission within 6 hours after onset of symptoms. Discharge outcome was dichotomized as good (modified Rankin Scale [mRS] 0-3) and poor (mRS 4-6) outcomes. The impacts of BHS, BS and SS on outcome were assessed in univariate and multivariable logistic regression models. Of 182 patients with spontaneous ICH, 26 (14.3%) presented with BHS, 37 (20.3%) with BS and 39 (21.4%) with SS. There was a substantial correlation between SS and BS (κ=0.701) and a moderate correlation between SS and BHS (κ=0.424). In univariable logistic regression, higher baseline hematoma volume ( P <0.001), intraventricular hemorrhage ( P =0.002) and the presence of BHS/BS/SS (all P <0.001) on admission CT scan were associated with poor outcome. Multivariable analysis identified intraventricular haemorrhage (odds ratio [OR] 2.22 per mL, P =0.022), baseline hematoma volume (OR 1.03 per mL, P <0.001) and SS on CTA (OR 11.43, P <0.001) as independent predictors of poor outcome, showing that SS compared to BS and BHS was more powerful to predict poor outcome. The NCCT BHS and BS are correlated with the CTA SS and are reliable predictors of poor outcome in patients with ICH. Of the CT variables indicating early hematoma expansion, SS on CTA was the most reliable outcome predictor. However, given their correlation with SS on CTA, BS and BHS on NCCT can be useful for predicting outcome if CTA is not obtainable.

  4. Chronic dietary magnesium-L-threonate speeds extinction and reduces spontaneous recovery of a conditioned taste aversion

    PubMed Central

    Mickley, G. Andrew; Hoxha, Nita; Luchsinger, Joseph L.; Rogers, Morgan M.; Wiles, Nathanael R.

    2013-01-01

    Elevation of brain magnesium enhances synaptic plasticity and extinction of conditioned fear memories. This experiment examined the generalizability of this phenomenon by studying the effects of a novel magnesium compound, magnesium-L-threonate (MgT), on conditioned taste aversion (CTA) extinction and spontaneous recovery (SR). Adult male Sprague-Dawley rats were maintained on a 23-hour water deprivation cycle and acquired a CTA following the taste of a CS [0.3% saccharin + 16mg/ml MgT (SAC+MgT)] paired with a US [81 mg/kg (i.p.) Lithium Chloride (LiCl)]. Following CTA acquisition, rats drank a water + MgT solution for up to 1 hour/day over the next 31 days. For 14 additional days, some animals continued water + MgT treatment, but others drank water only to allow MgT to be eliminated from the body. We then employed 2 different extinction paradigms: (1) CS-Only (CSO), in which SAC was presented, every-other day, or (2) Explicitly Unpaired (EU), in which both SAC and LiCl were presented, but on alternate days. EU extinction procedures have been shown to speed CTA extinction and reduce spontaneous recovery of the aversion. Throughout extinction, half of the rats in each group continued to drink MgT (now in SAC or supplemental water+MgT solution), whereas the other half drank SAC only/water only until SAC drinking reached ≥ 90% of baseline (asymptotic extinction). Rats receiving MgT just before/during extinction drank less SAC on the first day of extinction suggesting that they had retained a stronger CTA. MgT enhanced the rate of extinction. Furthermore, the MgT-treated rats showed a relatively modest SR of the CTA 30 days later – indicating that the extinction procedure was more effective for these animals. Our data suggest that long-term dietary MgT may enhance the consolidation/retention of a CTA, speed extinction, and inhibit SR of this learned aversion. PMID:23474371

  5. The catalytic A1 domains of cholera toxin and heat-labile enterotoxin are potent DNA adjuvants that evoke mixed Th1/Th17 cellular immune responses

    PubMed Central

    Bagley, Kenneth; Xu, Rong; Ota-Setlik, Ayuko; Egan, Michael; Schwartz, Jennifer; Fouts, Timothy

    2015-01-01

    DNA encoded adjuvants are well known for increasing the magnitude of cellular and/or humoral immune responses directed against vaccine antigens. DNA adjuvants can also tune immune responses directed against vaccine antigens to better protect against infection of the target organism. Two potent DNA adjuvants that have unique abilities to tune immune responses are the catalytic A1 domains of Cholera Toxin (CTA1) and Heat-Labile Enterotoxin (LTA1). Here, we have characterized the adjuvant activities of CTA1 and LTA1 using HIV and SIV genes as model antigens. Both of these adjuvants enhanced the magnitude of antigen-specific cellular immune responses on par with those induced by the well-characterized cytokine adjuvants IL-12 and GM-CSF. CTA1 and LTA1 preferentially enhanced cellular responses to the intracellular antigen SIVmac239-gag over those for the secreted HIVBaL-gp120 antigen. IL-12, GM-CSF and electroporation did the opposite suggesting differences in the mechanisms of actions of these diverse adjuvants. Combinations of CTA1 or LTA1 with IL-12 or GM-CSF generated additive and better balanced cellular responses to both of these antigens. Consistent with observations made with the holotoxin and the CTA1-DD adjuvant, CTA1 and LTA1 evoked mixed Th1/Th17 cellular immune responses. Together, these results show that CTA1 and LTA1 are potent DNA vaccine adjuvants that favor the intracellular antigen gag over the secreted antigen gp120 and evoke mixed Th1/Th17 responses against both of these antigens. The results also indicate that achieving a balanced immune response to multiple intracellular and extracellular antigens delivered via DNA vaccination may require combining adjuvants that have different and complementary mechanisms of action. PMID:26042527

  6. TH-AB-207A-03: Skin Dose to Patients Receiving Multiple CTA and CT Exams of the Head

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nawfel, RD; Young, G

    Purpose: To measure patient skin dose from CT angiography (CTA) and CT exams of the head, and determine if patients having multiple exams could receive cumulative doses that approach or exceed deterministic thresholds. Methods: This study was HIPAA compliant and conducted with IRB approval. Patient skin doses were measured over a 4 month period using nanoDot OSL dosimeters placed on the head of 52 patients for two CT scanners. On each scanner, 26 patients received CT exams (scanner 1: 10 females, 16 males, mean age 64.2 years; scanner 2: 18 females, 8 males, mean age 61.2 years). CT exam dosemore » metrics, CTDIvol and dose-length product (DLP) were recorded for each exam. Additionally, skin dose was measured on an acrylic skull phantom in each scanner and on a neuro-interventional imaging system using clinical protocols. Measured dose data was used to estimate peak skin dose (PSD) for 4 patients receiving multiple exams including CTA, head CT, and cerebral angiography. Results: For scanner 1, the mean PSD for CTA exams (98.9 ± 5.3 mGy) and for routine head CT exams (39.2 ± 3.7 mGy) agreed reasonably well with the PSD measured on the phantom, 105.4 mGy and 40.0 mGy, respectively. Similarly for scanner 2, the mean PSD for CTA exams (98.8 ± 7.4 mGy) and for routine head CT exams (42.9 ± 9.4 mGy) compared well with phantom measurements, 95.2 mGy and 37.6 mGy, respectively. In addition, the mean PSD was comparable between scanners for corresponding patient exams, CTA and routine head CT respectively. PSD estimates ranged from 1.9 – 4.5 Gy among 4 patients receiving multiple exams. Conclusion: Patients having several exams including both CTA and routine head CT may receive cumulative doses approaching or exceeding the threshold for single dose deterministic effects.« less

  7. Feasibility and safety of augmented-reality glass for computed tomography-assisted percutaneous revascularization of coronary chronic total occlusion: A single center prospective pilot study.

    PubMed

    Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Staruch, Adam D; Kepka, Cezary; Rokicki, Jakub K; Sieradzki, Bartosz; Witkowski, Adam

    2017-11-01

    Percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) may be facilitated by projection of coronary computed tomography angiography (CTA) datasets in the catheterization laboratory. There is no data on the feasibility and safety outcomes of CTA-assisted CTO PCI using a wearable augmented-reality glass. A total of 15 patients scheduled for elective antegrade CTO intervention were prospectively enrolled and underwent preprocedural coronary CTA. Three-dimensional and curved multiplanar CT reconstructions were transmitted to a head-mounted hands-free computer worn by interventional cardiologists during CTO PCI to provide additional information on CTO tortuosity and calcification. The results of CTO PCI using a wearable computer were compared with a time-matched prospective angiographic registry of 59 patients undergoing antegrade CTO PCI without a wearable computer. Operators' satisfaction was assessed by a 5-point Likert scale. Mean age was 64 ± 8 years and the mean J-CTO score was 2.1 ± 0.9 in the CTA-assisted group. The voice-activated co-registration and review of CTA images in a wearable computer during CTO PCI were feasible and highly rated by PCI operators (4.7/5 points). There were no major adverse cardiovascular events. Compared with standard CTO PCI, CTA-assisted recanalization of CTO using a wearable computer showed more frequent selection of the first-choice stiff wire (0% vs 40%, p < 0.001) and lower contrast exposure (166 ± 52 vs 134 ± 43 ml, p = 0.03). Overall CTO success rates and safety outcomes remained similar between both groups. CTA-assisted CTO PCI using an augmented-reality glass is feasible and safe, and might reduce the resources required for the interventional treatment of CTO. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    PubMed

    Meshaal, Marwa Sayed; Kassem, Hussein Heshmat; Samir, Ahmad; Zakaria, Ayman; Baghdady, Yasser; Rizk, Hussein Hassan

    2015-01-01

    Infective endocarditis (IE) is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs). These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA) is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE. From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention. The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%). Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32%) had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%). The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture. Routine brain CT/CTA resulted in changes in the treatment plan in a significant proportion of patients with IE, even those without clinically evident neurological disease. Routine brain CT/CTA may be indicated in all hospitalized patients with IE.

  9. Evaluation of the Monitor-CTA Automatic Vehicle Monitoring System

    DOT National Transportation Integrated Search

    1974-03-01

    In June 1972 the Urban Mass Transportation Administration requested that the Transportation System Center of DOT perform an evaluation of the CTA (Chicago Transit Authority) Monitor-Automatic Vehicle Monitor (AVM) system. TSC planned the overall eval...

  10. Monte Carlo performance studies for the site selection of the Cherenkov Telescope Array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassan, T.; Arrabito, L.; Bernlöhr, K.

    The Cherenkov Telescope Array (CTA) represents the next generation of ground-based instruments for very-high-energy (VHE) gamma-ray astronomy, aimed at improving on the sensitivity of current-generation experiments by an order of magnitude and providing coverage over four decades of energy. The current CTA design consists of two arrays of tens of imaging atmospheric Cherenkov Telescopes, comprising Small, Medium and Large-Sized Telescopes, with one array located in each of the Northern and Southern Hemispheres. To study the effect of the site choice on the overall CTA performance and support the site evaluation process, detailed Monte Carlo simulations have been performed. These resultsmore » show the impact of different site-related attributes such as altitude, night-sky background and local geomagnetic field on CTA performance for the observation of VHE gamma rays.« less

  11. Design Concepts for the Cherenkov Telescope Array CTA: An Advanced Facility for Ground-Based High-Energy Gamma-Ray Astronomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Actis, M

    Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTAmore » is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.« less

  12. Monte Carlo performance studies for the site selection of the Cherenkov Telescope Array

    DOE PAGES

    Hassan, T.; Arrabito, L.; Bernlöhr, K.; ...

    2017-05-03

    The Cherenkov Telescope Array (CTA) represents the next generation of ground-based instruments for very-high-energy (VHE) gamma-ray astronomy, aimed at improving on the sensitivity of current-generation experiments by an order of magnitude and providing coverage over four decades of energy. The current CTA design consists of two arrays of tens of imaging atmospheric Cherenkov Telescopes, comprising Small, Medium and Large-Sized Telescopes, with one array located in each of the Northern and Southern Hemispheres. To study the effect of the site choice on the overall CTA performance and support the site evaluation process, detailed Monte Carlo simulations have been performed. These resultsmore » show the impact of different site-related attributes such as altitude, night-sky background and local geomagnetic field on CTA performance for the observation of VHE gamma rays.« less

  13. 77 FR 52075 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... all registered transfer agents to report to issuers and the appropriate regulatory agency in the event... certificates presented to the transfer agent for purchase, redemption or transfer. In addition, the rule requires transfer agents to report to the appropriate regulatory agency in the event of a failure to post...

  14. Differential effects of beta-adrenergic receptor blockade in the medial prefrontal cortex during aversive and incidental taste memory formation.

    PubMed

    Reyes-López, J; Nuñez-Jaramillo, L; Morán-Guel, E; Miranda, M I

    2010-08-11

    The medial prefrontal cortex (mPFC) is a brain area crucial for memory, attention, and decision making. Specifically, the noradrenergic system in this cortex is involved in aversive learning, as well as in the retrieval of these memories. Some evidence suggests that this area has an important role during taste memory, particularly during conditioned taste aversion (CTA), a model of aversive memory. Despite some previous evidence, there is scarce information about the role of adrenergic receptors in the mPFC during formation of aversive taste memory and appetitive/incidental taste memory. The goal of this research was to evaluate the role of mPFC beta-adrenergic receptors during CTA acquisition/consolidation or CTA retrieval, as well as during incidental taste memory formation using the model of latent inhibition of CTA. The results showed that infusions in the mPFC of the beta-adrenergic antagonist propranolol before CTA acquisition impaired both short- and long-term aversive taste memory formation, and also that propranolol infusions before the memory test impaired CTA retrieval. However, propranolol infusions before pre-exposure to the taste during the latent inhibition procedure had no effect on incidental taste memory acquisition or consolidation. These data indicate that beta-adrenergic receptors in the mPFC have different functions during taste memory formation: they have an important role during aversive taste association as well as during aversive retrieval but not during incidental taste memory formation. Copyright (c) 2010 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. The contribution of clinical assessments to the diagnostic algorithm of pulmonary embolism.

    PubMed

    Turan, Onur; Turgut, Deniz; Gunay, Turkan; Yilmaz, Erkan; Turan, Ayse; Akkoclu, Atila

    2017-01-01

    Pulmonary thromboembolism (PE) is a major disease in respiratory emergencies. Thoracic CT angiography (CTA) is an important method of visualizing PE. Because of the high radiation and contrast exposure, the method should be performed selectively in patients in whom PE is suspected. The aim of the study was to identify the role of clinical scoring systems utilizing CTA results to diagnose PE. The study investigated 196 patients referred to the hospital emergency service in whom PE was suspected and CTA performed. They were evaluated by empirical, Wells, Geneva and Miniati assessments and classified as low, intermediate and high clinical probability. They were also classified according to serum D-dimer levels. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated and evaluated according to CTA findings. Empirical scoring was found to have the highest sensitivity, while the Wells system had the highest specificity. When low D-dimer levels and "low probabilty" were evaluated together for each scoring system, the sensitivity was found to be 100% for all methods. Wells scoring with a cut-off score of 4 had the highest specificity (56.1%). Clinical scoring systems may be guides for patients in whom PE is suspected in the emergency department. The empirical and Wells scoring systems are effective methods for patient selection. Adding evaluation of D-dimer serum levels to the clinical scores could identify patients in whom CTA should be performed. Since CTA can only be used conservatively, the use of clinical scoring systems in conjunction with D-dimer levels can be a useful guide for patient selection.

  16. Denver screening protocol for blunt cerebrovascular injury reduces the use of multi-detector computed tomography angiography.

    PubMed

    Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian

    2014-06-01

    Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.

  17. Cost analysis of non-invasive fractional flow reserve derived from coronary computed tomographic angiography in Japan.

    PubMed

    Kimura, Takeshi; Shiomi, Hiroki; Kuribayashi, Sachio; Isshiki, Takaaki; Kanazawa, Susumu; Ito, Hiroshi; Ikeda, Shunya; Forrest, Ben; Zarins, Christopher K; Hlatky, Mark A; Norgaard, Bjarne L

    2015-01-01

    Percutaneous coronary intervention (PCI) based on fractional flow reserve (FFRcath) measurement during invasive coronary angiography (CAG) results in improved patient outcome and reduced healthcare costs. FFR can now be computed non-invasively from standard coronary CT angiography (cCTA) scans (FFRCT). The purpose of this study is to determine the potential impact of non-invasive FFRCT on costs and clinical outcomes of patients with suspected coronary artery disease in Japan. Clinical data from 254 patients in the HeartFlowNXT trial, costs of goods and services in Japan, and clinical outcome data from the literature were used to estimate the costs and outcomes of 4 clinical pathways: (1) CAG-visual guided PCI, (2) CAG-FFRcath guided PCI, (3) cCTA followed by CAG-visual guided PCI, (4) cCTA-FFRCT guided PCI. The CAG-visual strategy demonstrated the highest projected cost ($10,360) and highest projected 1-year death/myocardial infarction rate (2.4 %). An assumed price for FFRCT of US $2,000 produced equivalent clinical outcomes (death/MI rate: 1.9 %) and healthcare costs ($7,222) for the cCTA-FFRCT strategy and the CAG-FFRcath guided PCI strategy. Use of the cCTA-FFRCT strategy to select patients for PCI would result in 32 % lower costs and 19 % fewer cardiac events at 1 year compared to the most commonly used CAG-visual strategy. Use of cCTA-FFRCT to select patients for CAG and PCI may reduce costs and improve clinical outcome in patients with suspected coronary artery disease in Japan.

  18. 17 CFR 5.19 - Pending legal proceedings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., CPO, CTA or IB is a party or to which its property or assets is subject with respect to retail forex... merchant, CPO, CTA or IB and alleging violations, with regard to retail forex transactions, of: (1) The Act...

  19. 17 CFR 5.19 - Pending legal proceedings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., CPO, CTA or IB is a party or to which its property or assets is subject with respect to retail forex... merchant, CPO, CTA or IB and alleging violations, with regard to retail forex transactions, of: (1) The Act...

  20. Role for the rostromedial tegmental nucleus in signaling the aversive properties of alcohol

    PubMed Central

    Glover, Elizabeth J.; McDougle, Molly J.; Siegel, Griffin S.; Jhou, Thomas C.; Chandler, L. Judson

    2016-01-01

    Background While the rewarding effects of alcohol contribute significantly to its addictive potential, it is becoming increasingly appreciated that alcohol’s aversive properties also play an important role in the propensity to drink. Despite this, the neurobiological mechanism for alcohol’s aversive actions is not well understood. The rostromedial tegmental nucleus (RMTg) was recently characterized for its involvement in aversive signaling and has been shown to encode the aversive properties of cocaine, yet its involvement in alcohol’s aversive actions have not been elucidated. Methods Adult male and female Long-Evans rats underwent conditioned taste aversion (CTA) procedures where exposure to a novel saccharin solution was paired with i.p. administration of saline, lithium chloride (LiCl), or ethanol (EtOH). Control rats underwent the same paradigm except that drug and saccharin exposure were explicitly unpaired. Saccharin consumption was measured on test day in the absence of drug administration and rats were sacrificed 90–105 min following access to saccharin. Brains were subsequently harvested and processed for cFos immunohistochemistry. The number of cFos labeled neurons was counted in the RMTg and the lateral habenula (LHb) – a region that sends prominent glutamatergic input to the RMTg. Results In rats that received paired drug and saccharin exposure, EtOH and LiCl induced significant CTA compared to saline to a similar degree in males and females. Both EtOH- and LiCl-induced CTA significantly enhanced cFos expression in the RMTg and LHb but not the hippocampus. Similar to behavioral measures, no significant effect of sex on CTA-induced cFos expression was observed. cFos expression in both the RMTg and LHb was significantly correlated to CTA magnitude with greater cFos being associated with more pronounced CTA. In addition, cFos expression in the RMTg was positively correlated with LHb cFos. Conclusions These data suggest that the RMTg and LHb are involved in the expression of CTA and are consistent with previous work implicating the RMTg in aversive signaling. Furthermore, increased cFos expression in the RMTg following EtOH-induced CTA suggests that this region plays a role in signaling alcohol’s aversive properties. PMID:27388762

  1. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.

    PubMed

    Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu

    2016-09-01

    Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that the low tube voltage CT protocol is a powerful tool to reduce the radiation dose in CTA, especially with pCTA and cCTA. © 2016 John Wiley & Sons Ltd.

  2. 76 FR 16707 - Rule 17Ad-17; Transfer Agents', Brokers', and Dealers' Obligation To Search for Lost...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... 3235-AL11 Rule 17Ad-17; Transfer Agents', Brokers', and Dealers' Obligation To Search for Lost Securityholders; Paying Agents' Obligation To Search for Missing Securityholders AGENCY: Securities and Exchange... Rule 17Ad-17, ``Transfer Agents' Obligation to Search for Lost Securityholders'' to: extend to brokers...

  3. 76 FR 20061 - Self-Regulatory Organizations; The Depository Trust Company; Order Granting Approval of a...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ... Relating to the Requirement To Maintain a Balance Certificate in the Fast Automated Securities Transfer... transfer agents'') hold DTC securities in the form of balance certificates.\\4\\ The balance certificates are... issue for which the FAST transfer agent acts as transfer agent. The Balance Certificate Agreement is...

  4. Analyzing railroad dispatchers' strategies : a cognitive task analysis of a distributed planning task

    DOT National Transportation Integrated Search

    1998-10-11

    This paper describes a preliminary cognitive task analysis (CTA) that is being conducted to examine how experienced train dispatchers manage and schedule trains. The CTA uses ethnographic field observations and structured interview techniques. The ob...

  5. Production of permeable cellulose triacetate membranes

    DOEpatents

    Johnson, B.M.

    1986-12-23

    A phase inversion process for the preparation of cellulose triacetate (CTA) and regenerated cellulose membranes is disclosed. Such membranes are useful as supports for liquid membranes in facilitated transport processes, as microfiltration membranes, as dialysis or ultrafiltration membranes, and for the preparation of ion-selective electrodes. The process comprises the steps of preparing a casting solution of CTA in a solvent comprising a mixture of cyclohexanone and methylene chloride, casting a film from the casting solution, and immersing the cast film in a methanol bath. The resulting CTA membrane may then be hydrolyzed to regenerated cellulose using conventional techniques.

  6. Production of permeable cellulose triacetate membranes

    DOEpatents

    Johnson, Bruce M.

    1986-01-01

    A phase inversion process for the preparation of cellulose triacetate (CTA) and regenerated cellulose membranes is disclosed. Such membranes are useful as supports for liquid membranes in facilitated transport processes, as microfiltration membranes, as dialysis or ultrafiltration membranes, and for the preparation of ion-selective electrodes. The process comprises the steps of preparing a casting solution of CTA in a solvent comprising a mixture of cyclohexanone and methylene chloride, casting a film from the casting solution, and immersing the cast film in a methanol bath. The resulting CTA membrane may then be hydrolyzed to regenerated cellulose using conventional techniques.

  7. 3.0Tesla magnetic resonance angiography (MRA) for comprehensive renal evaluation of living renal donors: pilot study with computerized tomography angiography (CTA) comparison.

    PubMed

    Gulati, Mittul; Dermendjian, Harout; Gómez, Ana M; Tan, Nelly; Margolis, Daniel J; Lu, David S; Gritsch, H Albin; Raman, Steven S

    2016-01-01

    Most living related donor (LRD) kidneys are harvested laparoscopically. Renal vascular anatomy helps determine donor suitability for laparoscopic nephrectomy. Computed tomography angiography (CTA) is the current gold standard for preoperative imaging; magnetic resonance angiography (MRA) offers advantages including lack of ionizing radiation and lower incidence of contrast reactions. We evaluated 3.0T MRA for assessing renal anatomy of LRDs. Thirty consecutive LRDs underwent CTA followed by 3.0T MRA. Data points included number and branching of vessels, incidental findings, and urothelial opacification. Studies were individually evaluated by three readers blinded to patient data. Studies were reevaluated in consensus with discrepancies revealed, and final consensus results were labeled "truth". Compared with consensus "truth", both computed tomography (CT) and magnetic resonance imaging were highly accurate for assessment of arterial and venous anatomy, although CT was superior for detection of late venous confluence as well as detection of renal stones. Both modalities were comparable in opacification of lower ureters and bladder; MRA underperformed CTA for opacification of upper urinary tracts. 3.0T MRA enabled excellent detection of comprehensive renal anatomy compared to CTA in LRDs. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Establishing a composite tissue allotransplantation program.

    PubMed

    Pomahac, Bohdan

    2012-01-01

    Composite tissue allotransplantation (CTA) has emerged as a promising surgical option to restore the form and function of missing or severely damaged structures such as the face, hands, or trachea. Currently, there are four active CTA programs in the United States and numerous others under development. The process of development of a CTA program in the United States involves successful collaboration between a strong project leader with vested clinical research interest, a multidisciplinary team of investigators, an Institutional Review Board, a regional Organ Processing Organization (PO), and the hospital's administration. The process of establishment of a CTA program can be slow and lengthy, therefore the project leader must strive to maintain the enthusiasm alive and drive the project forward. At all phases of development, the project must remain focused on the patients, must recognize and address all potential patient safety issues, must take into account the concerns, issues and logistic hurdles faced by the OPO, and must be financially responsible by ensuring that postoperative costs related to medical care and life-long immunosuppression are covered by medical insurance. This article describes the process of establishment of a CTA program at Brigham and Women's Hospital, Boston, MA with special emphasis on strategy and planning. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Pre-exposure to wheel running disrupts taste aversion conditioning.

    PubMed

    Salvy, Sarah-Jeanne; Pierce, W David; Heth, Donald C; Russell, James C

    2002-05-01

    When rats are given access to a running wheel after drinking a flavored solution, they subsequently drink less of that flavor solution. It has been suggested that running produces a conditioned taste aversion (CTA). This study explored whether CTA is eliminated by prior exposure to wheel running [i.e., unconditioned stimulus (UCS) pre-exposure effect]. The rats in the experimental group (UW) were allowed to wheel run for 1 h daily for seven consecutive days of pre-exposure. Rats in the two other groups had either access to locked wheels (LW group) or were maintained in their home cages (HC group) during the pre-exposure days. All rats were then exposed to four paired and four unpaired trials using a "ABBAABBA" design. Conditioning trials were composed of one flavored liquid followed by 60-min access to wheel running. For the unpaired trials, rats received a different flavor not followed by the opportunity to run. All rats were then initially tested for water consumption followed by tests of the two flavors (paired or unpaired) in a counterbalanced design. Rats in the UW group show no CTA to the liquid paired with wheel running, whereas LW and HC groups developed CTA. These results indicate that pre-exposure to wheel running (i.e., the UCS), eliminates subsequent CTA.

  10. [Preoperative assessment of renal vascular anatomy for donor nephrectomy: Is CT superior to MRI?].

    PubMed

    Arvin-Berod, A; Bricault, I; Terrier, N; Skowron, O; Cadi, P; Boillot, B; Thuillier, C; Cluze, C; Descotes, J-L; Rambeaud, J-J; Long, J-A

    2011-01-01

    computed tomography angiography (CTA) and magnetic resonance angiography (MRA) are both used in the preoperative assessment of vascular anatomy before donor nephrectomy. Our objective was to determine retrospectively and to compare the sensitivity of CTA and MRA imaging in preoperative renal vascularisation in living kidney donors. between 1999 and 2007, 42 kidney donors were assessed in our center: 27 by MRA, 10 by CTA, and five by both techniques. Images were interpreted using multiplanar reconstructions. Results were compared retrospectively with peroperative findings; discordant cases were re-examined by an experienced radiologist. Numbers of vessels detected with imaging methods was compared with numbers actually found at the operating time. MRA showed 35/43 arteries (Se 81.4 %) and 33/34 veins (Se 97.1 %), and CTA showed 18/18 arteries (Se 100 %) and 15/16 veins (Se 93.8 %). The presence of multiple arteries was detected in only one third of cases (3/9) on MRI scans; this difference was statistically significant. The missed arteries were not detected on second examination of the MRI scans with the knowledge of peroperative findings. MRA is less sensitive than CTA for preoperative vascularisation imaging in living renal donors, especially in the detection of multiple renal arteries. 2010 Elsevier Masson SAS. All rights reserved.

  11. Cognitive Task Analysis for Instructional Design: Applications in Distance Education.

    ERIC Educational Resources Information Center

    Redding, Richard E.

    1995-01-01

    Provides an overview of cognitive task analysis-based instructional design (CTA-BID) and its applications in the design of instructional and testing materials for distance education. Reviews developments in education, psychology, and instructional design that complement CTA-BID. (Author/AEF)

  12. Audit of CT reporting standards in cases of intracerebral haemorrhage at a comprehensive stroke centre in Australia.

    PubMed

    Barras, Christen D; Asadi, Hamed; Phal, Pramit M; Tress, Brian M; Davis, Stephen M; Desmond, Patricia M

    2016-12-01

    Multiple CT-derived biomarkers that are predictive of intracerebral haemorrhage (ICH) growth and outcome have been described in the literature, but the extent to which these appear in imaging reports of ICH is unknown. The aim of this retrospective process audit was to determine which of the known predictors of ICH outcome was recorded in reports of the disease, with a view to providing reporting recommendations, as appropriate. We examined the initial CT report of patients diagnosed with ICH presenting to a metropolitan comprehensive stroke centre and meeting inclusion criteria during the audit period between 1 March 2013 and 28 February 2014. Each report was assessed for the inclusion of the following ICH characteristics: the number of measurement dimensions; volume; location; hydrocephalus; shape; density; 'CTA spot sign' (where CTA was performed). A total of 100 patients met audit inclusion criteria. At least one ICH dimension was recorded in 90% of reports; however, 39% did not include the measurements in three dimensions and volume was reported in just 6%. No ICH dimension was recorded in 10% of reports. With the exception of density and shape, reporting of other CT features exceeded 95%. Where CTA was performed (58%), 14 (24%) of 58 reported the 'CTA spot sign' status. In this audit, volume was the most under-reported of the established ICH characteristics predictive of ICH outcome. Readily calculated from multiplanar reformats using the ABC/2 technique, the routine reporting of ICH volume is recommended. More reporting attention to ICH density heterogeneity and shape irregularity is encouraged, given their emerging importance. Where acute CTA is performed, the presence of any dynamic haemorrhage (CTA spot sign) should be reported. © 2016 The Royal Australian and New Zealand College of Radiologists.

  13. Morphology-based three-dimensional segmentation of coronary artery tree from CTA scans

    NASA Astrophysics Data System (ADS)

    Banh, Diem Phuc T.; Kyprianou, Iacovos S.; Paquerault, Sophie; Myers, Kyle J.

    2007-03-01

    We developed an algorithm based on a rule-based threshold framework to segment the coronary arteries from angiographic computed tomography (CTA) data. Computerized segmentation of the coronary arteries is a challenging procedure due to the presence of diverse anatomical structures surrounding the heart on cardiac CTA data. The proposed algorithm incorporates various levels of image processing and organ information including region, connectivity and morphology operations. It consists of three successive stages. The first stage involves the extraction of the three-dimensional scaffold of the heart envelope. This stage is semiautomatic requiring a reader to review the CTA scans and manually select points along the heart envelope in slices. These points are further processed using a surface spline-fitting technique to automatically generate the heart envelope. The second stage consists of segmenting the left heart chambers and coronary arteries using grayscale threshold, size and connectivity criteria. This is followed by applying morphology operations to further detach the left and right coronary arteries from the aorta. In the final stage, the 3D vessel tree is reconstructed and labeled using an Isolated Connected Threshold technique. The algorithm was developed and tested on a patient coronary artery CTA that was graciously shared by the Department of Radiology of the Massachusetts General Hospital. The test showed that our method constantly segmented the vessels above 79% of the maximum gray-level and automatically extracted 55 of the 58 coronary segments that can be seen on the CTA scan by a reader. These results are an encouraging step toward our objective of generating high resolution models of the male and female heart that will be subsequently used as phantoms for medical imaging system optimization studies.

  14. Utilization of cardiac computed tomography angiography and outpatient invasive coronary angiography in Ontario, Canada.

    PubMed

    Roifman, Idan; Rezai, Mohammad R; Wijeysundera, Harindra C; Chow, Benjamin J W; Wright, Graham A; Tu, Jack V

    2015-01-01

    Cardiac computed tomography angiography (coronary CTA) has emerged as a non-invasive method of diagnosing coronary artery disease. The extent of utilization and uptake of this technology since initiation of its funding by the government of Ontario is unknown. The aim of our study was to examine coronary CTA utilization and the rates of elective invasive coronary angiography and revascularization before and after funding initiation. We studied all coronary CTAs performed on adults in Ontario after initiation of funding. We also used an interrupted time series analysis to compare the average monthly rates of invasive angiography and revascularization before and after initiation of funding. There was an initial steep increase in age-and sex-standardized rates of coronary CTA from 5.0 to 11.4/100,000 over the first two quarters after funding initiation. Afterwards, there was a gradual increase in utilization from 11.4 to 17.1/100,000 over two subsequent calendar years. There was a significant reduction in both the mean monthly outpatient invasive coronary angiography (from 20.7 to 19.9 per 100,000 (p = 0.0004)) and revascularization (from 4.9 to 4.4 per 100,000 (p < 0.0001)) rates in the three years following introduction of the coronary CTA billing code as compared to the three prior to its introduction. Since the introduction of coronary CTA funding in Ontario, there has been a steady and controlled increase in its utilization. The increasing use of coronary CTA was associated with a reduction in both the rates of invasive angiography and revascularization. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  15. Dissociation between peripheral blood chimerism and tolerance to hindlimb composite tissue transplants: preferential localization of chimerism in donor bone.

    PubMed

    Rahhal, Dina N; Xu, Hong; Huang, Wei-Chao; Wu, Shengli; Wen, Yujie; Huang, Yiming; Ildstad, Suzanne T

    2009-09-27

    Mixed chimerism induces donor-specific tolerance to composite tissue allotransplants (CTAs). In the present studies, we used a nonmyeloablative conditioning approach to establish chimerism and promote CTA acceptance. Wistar Furth (RT1A(u)) rats were conditioned with 600 to 300 cGy total body irradiation (TBI, day-1), and 100 x 10(6) T-cell-depleted ACI (RT1A(abl)) bone marrow cells were transplanted on day 0, followed by a 11-day course of tacrolimus and one dose of antilymphocyte serum (day 10). Heterotopic osteomyocutaneous flap transplantation was performed 4 to 6 weeks after bone marrow transplantation. Mixed chimerism was initially achieved in almost all recipients, but long-term acceptance of CTA was only achieved in rats treated with 600 cGy TBI. When anti-alphabeta-T-cell receptor (TCR) monoclonal antibody (mAb) (day-3) was added into the regimens, donor chimerism was similar to recipients preconditioned without anti-alphabeta-TCR mAb. However, the long-term CTA survival was significantly improved in chimeras receiving more than or equal to 300 cGy TBI plus anti-alphabeta-TCR mAb. Higher levels of donor chimerism were associated with CTA acceptance. The majority of flap acceptors lost peripheral blood chimerism within 6 months. However, donor chimerism persisted in the transplanted bone at significantly higher levels compared with other hematopoietic compartments. The compartment donor chimerism may be responsible for the maintenance of tolerance to CTA. Long-term acceptors were tolerant to a donor skin graft challenge even in the absence of peripheral blood chimerism. Mixed chimerism established by nonmyeloablative conditioning induces long-term acceptance of CTA, which is associated with persistent chimerism preferentially in the transplanted donor bone.

  16. Automatic detection of left and right ventricles from CTA enables efficient alignment of anatomy with myocardial perfusion data.

    PubMed

    Piccinelli, Marina; Faber, Tracy L; Arepalli, Chesnal D; Appia, Vikram; Vinten-Johansen, Jakob; Schmarkey, Susan L; Folks, Russell D; Garcia, Ernest V; Yezzi, Anthony

    2014-02-01

    Accurate alignment between cardiac CT angiographic studies (CTA) and nuclear perfusion images is crucial for improved diagnosis of coronary artery disease. This study evaluated in an animal model the accuracy of a CTA fully automated biventricular segmentation algorithm, a necessary step for automatic and thus efficient PET/CT alignment. Twelve pigs with acute infarcts were imaged using Rb-82 PET and 64-slice CTA. Post-mortem myocardium mass measurements were obtained. Endocardial and epicardial myocardial boundaries were manually and automatically detected on the CTA and both segmentations used to perform PET/CT alignment. To assess the segmentation performance, image-based myocardial masses were compared to experimental data; the hand-traced profiles were used as a reference standard to assess the global and slice-by-slice robustness of the automated algorithm in extracting myocardium, LV, and RV. Mean distances between the automated and the manual 3D segmented surfaces were computed. Finally, differences in rotations and translations between the manual and automatic surfaces were estimated post-PET/CT alignment. The largest, smallest, and median distances between interactive and automatic surfaces averaged 1.2 ± 2.1, 0.2 ± 1.6, and 0.7 ± 1.9 mm. The average angular and translational differences in CT/PET alignments were 0.4°, -0.6°, and -2.3° about x, y, and z axes, and 1.8, -2.1, and 2.0 mm in x, y, and z directions. Our automatic myocardial boundary detection algorithm creates surfaces from CTA that are similar in accuracy and provide similar alignments with PET as those obtained from interactive tracing. Specific difficulties in a reliable segmentation of the apex and base regions will require further improvements in the automated technique.

  17. Venous phase of computed tomography angiography increases spot sign detection, but intracerebral hemorrhage expansion is greater in spot signs detected in arterial phase.

    PubMed

    Rodriguez-Luna, David; Dowlatshahi, Dar; Aviv, Richard I; Molina, Carlos A; Silva, Yolanda; Dzialowski, Imanuel; Lum, Cheemun; Czlonkowska, Anna; Boulanger, Jean-Martin; Kase, Carlos S; Gubitz, Gord; Bhatia, Rohit; Padma, Vasantha; Roy, Jayanta; Stewart, Teri; Huynh, Thien J; Hill, Michael D; Demchuk, Andrew M

    2014-03-01

    Variability in computed tomography angiography (CTA) acquisitions may be one explanation for the modest accuracy of the spot sign for predicting intracerebral hemorrhage expansion detected in the multicenter Predicting Hematoma Growth and Outcome in Intracerebral Hemorrhage Using Contrast Bolus CT (PREDICT) study. This study aimed to determine the frequency of the spot sign in intracerebral hemorrhage and its relationship with hematoma expansion depending on the phase of image acquisition. PREDICT study was a prospective observational cohort study of patients with intracerebral hemorrhage presenting within 6 hours from onset. A post hoc analysis of the Hounsfield units of an artery and venous structure were measured on CTA source images of the entire PREDICT cohort in a core laboratory. Each CTA study was classified into arterial or venous phase and into 1 of 5 specific image acquisition phases. Significant hematoma expansion and total hematoma enlargement were recorded at 24 hours. Overall (n=371), 77.9% of CTA were acquired in arterial phase. The spot sign, present in 29.9% of patients, was more frequently seen in venous phase as compared with arterial phase (39% versus 27.3%; P=0.041) and the later the phase of image acquisition (P=0.095). Significant hematoma expansion (P=0.253) and higher total hematoma enlargement (P=0.019) were observed more frequently among spot sign-positive patients with earlier phases of image acquisition. Later image acquisition of CTA improves the frequency of spot sign detection. However, spot signs identified in earlier phases may be associated with greater absolute enlargement. A multiphase CTA including arterial and venous acquisitions could be optimal in patients with intracerebral hemorrhage.

  18. Chemical stability and cytotoxicity of human insulin loaded in cationic DPPC/CTA/DDAB liposomes.

    PubMed

    Manosroi, Aranya; Khositsuntiwong, Narinthorn; Komno, Chonlada; Manosroi, Worapaka; Werner, Rolf G; Manosoi, Jiradej

    2011-04-01

    Liposomes were prepared from DPPC (dipalmitoyl phosphatidyl choline) mixed with Chol (cholesterol) and CTA [cholest-5-en-3-ol(3beta)(trimethylammonio) acetate] or DDAB (dioctadecyl dimethyl ammonium bromide) at various molar ratios by chloroform film method with sonication. The most physical stable (no sedimentation with an average zeta potential value of 47.7+/-1.44 mV) liposomal formulation (DPPC/CTA/DDAB at 7:2:1 molar ratio) was selected to load with human insulin (0.45 mg/mL) by the freeze dried empty liposomes (FDELs) method with the entrapment efficiency of human insulin of 62.72% (determined by gel filtration). Liposomes were spherical shape with unilamellar structure and an average size of 2.26+/-0.87 microm determined by TEM. The percentages of insulin remaining in liposomes when stored at 4+/-2, 30+/-2 and 45+/-2 degrees C for 4 months were 26.21, 36.86 and 15.75% which were higher than human insulin solution of 6.13, 11.31 and 2.61 times, respectively. The percentages of entrapment of human insulin were 62.72 at initial and at 31.72, 64.10 and 8.10 when kept at 4+/-2, 30+/-2 and 45+/-2 degrees C, respectively, for 4 months. The synthesized cationic lipid, CTA, and the DPPC/Chol/CTA liposomes loaded with human insulin demonstrated no cytotoxicity on normal human skin fibroblast but some cytotoxic effects on mouth epidermal cancer cell line. This study has demonstrated the enhancement of chemical stability of human insulin with no cytotoxicity when loaded this protein in cationic DPPC/CTA/DDAB liposomes. The results indicated the potential application of this cationic liposomal formulation for topical therapeutic use.

  19. Computed Tomography Angiography in Patients Evaluated for Acute Pulmonary Embolism with Low Serum D-dimer Levels: A Prospective Study.

    PubMed

    Gimber, Lana Hirai; Travis, R Ing; Takahashi, Jayme M; Goodman, Torrey L; Yoon, Hyo-Chun

    2009-01-01

    Pulmonary computed tomography angiography (CTA) and the Wells criteria both have interobserver variability in the assessment of pulmonary embolism (PE). Quantitative D-dimer assay findings have been shown to have a high negative predictive value in patients with low pretest probability of PE. Evaluate roles for clinical probability and CTA in Emergency Department (ED) patients suspected of acute PE but having a low serum D-dimer level. Prospective observational study of ED patients with possible PE who underwent pulmonary CTA and had D-dimer levels

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: anni.sailer@mumc.nl; Haan, Michiel W. de, E-mail: m.de.haan@mumc.nl; Graaf, Rick de, E-mail: r.de.graaf@mumc.nl

    PurposeThis study was designed to evaluate the feasibility of endovascular guidance by means of live fluoroscopy fusion with magnetic resonance angiography (MRA) and computed tomography angiography (CTA).MethodsFusion guidance was evaluated in 20 endovascular peripheral artery interventions in 17 patients. Fifteen patients had received preinterventional diagnostic MRA and two patients had undergone CTA. Time for fluoroscopy with MRA/CTA coregistration was recorded. Feasibility of fusion guidance was evaluated according to the following criteria: for every procedure the executing interventional radiologists recorded whether 3D road-mapping provided added value (yes vs. no) and whether PTA and/or stenting could be performed relying on the fusionmore » road-map without need for diagnostic contrast-enhanced angiogram series (CEAS) (yes vs. no). Precision of the fusion road-map was evaluated by recording maximum differences between the position of the vasculature on the virtual CTA/MRA images and conventional angiography.ResultsAverage time needed for image coregistration was 5 ± 2 min. Three-dimensional road-map added value was experienced in 15 procedures in 12 patients. In half of the patients (8/17), intervention was performed relying on the fusion road-map only, without diagnostic CEAS. In two patients, MRA roadmap showed a false-positive lesion. Excluding three patients with inordinate movements, mean difference in position of vasculature on angiography and MRA/CTA road-map was 1.86 ± 0.95 mm, implying that approximately 95 % of differences were between 0 and 3.72 mm (2 ± 1.96 standard deviation).ConclusionsFluoroscopy with MRA/CTA fusion guidance for peripheral artery interventions is feasible. By reducing the number of CEAS, this technology may contribute to enhance procedural safety.« less

  1. Coronary artery atherosclerosis and risk stratification in young adults with an intermediate pretest likelihood detected by multidetector computed tomography.

    PubMed

    Hou, Zhi-hui; Lu, Bin; Gao, Yang; Yu, Fang-fang; Cao, Hui-li; Jiang, Shi-liang; Roy, Sion K; Budoff, Matthew J

    2012-11-01

    To document the prevalence of coronary artery disease (CAD) and major adverse cardiac events (MACE) in patients younger than 45 years of age with intermediate pretest likelihood of CAD, and to determine whether coronary computed tomography angiography (cCTA) is useful for risk stratification of this cohort. We followed 452 intermediate pretest likelihood (according to Diamond and Forrester) outpatients who were suspected of CAD and underwent cCTA. They were all younger than 45 years old. The endpoint was MACE, defined as composite cardiac death, nonfatal myocardial infarction, or coronary revascularization. Follow-up was completed in 427 patients (94.5%) with a median follow-up period of 1081 days. No plaque was noted in 357 (83.6%) patients. Nonsignificant CAD was noted in 33 (7.7%) individuals and 37 (8.7%) patients with significant CAD. At the end of the follow-up period, 12 (2.8%) patients experienced MACE. The annualized event rate was 0.2% in patients with no plaque, 2.0% in patients with nonsignificant CAD, and 7.3% in patients with significant CAD. Hypertension, smoking, and significant CAD in cCTA were significant predictors of MACE in univariate analysis. Moreover, cCTA remained a predictor (P < .001) of events after multivariate correction (hazard ratio: 8.345, 95% CI: 3.438-17.823, P < .001). The prevalence of CAD and MACE in young adults with an intermediate pretest likelihood of CAD was considerable. cCTA is effective in restratifying patients into either a low or high posttest risk group. These results further emphasize the usefulness of cCTA in this cohort. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  2. Ethanol-induced conditioned taste aversion in male sprague-dawley rats: impact of age and stress.

    PubMed

    Anderson, Rachel I; Varlinskaya, Elena I; Spear, Linda P

    2010-12-01

    Age-specific characteristics may contribute to the elevation in ethanol intake commonly reported among adolescents compared to adults. This study was designed to examine age-related differences in sensitivity to ethanol's aversive properties using a conditioned taste aversion (CTA) procedure with sucrose serving as the conditioned stimulus (CS). Given that ontogenetic differences in responsiveness to stressors have been previously reported, the role of stressor exposure on the development of CTA was also assessed. Experiment 1 examined the influence of 5 days of prior restraint stress exposure on the expression of CTA in a 2-bottle test following 1 pairing of a sucrose solution with ethanol. In Experiment 2, the effects of 7 days of social isolation on the development of CTA were observed using a 1-bottle test following multiple sucrose-ethanol pairings. This study revealed age-related differences in the development of ethanol-induced CTA. In Experiment 1, adolescents required a higher dose of ethanol than adults to demonstrate an aversion. In Experiment 2, adolescents required not only a higher ethanol dose but also more pairings of ethanol with the sucrose CS. No effects of prior stressor exposure were observed in either experiment. Together, these experiments demonstrate an adolescent-specific insensitivity to the aversive properties of ethanol that elicit CTA, a pattern not influenced by repeated restraint stress or housing in social isolation. This age-related insensitivity to the dysphoric effects of ethanol is consistent with other work from our laboratory, adding further to the evidence that adolescent rats are less susceptible to negative consequences of ethanol that may serve as cues to curb consumption. Copyright © 2010 by the Research Society on Alcoholism.

  3. Differences in sensitivity to ethanol-induced conditioned taste aversions emerge after pre- or post-pubertal gonadectomy in male and female rats.

    PubMed

    Morales, Melissa; Spear, Linda P

    2013-03-01

    We have previously demonstrated that gonadectomy either prior to (early) or after (late) puberty elevated ethanol consumption in males to levels similar to intact adult females-effects that were attenuated by testosterone replacement. To assess whether alterations in the aversive effects of ethanol might contribute to gonadectomy-associated increases in ethanol intake in males, the present study examined the impact of gonadectomy on conditioned taste aversions (CTA) to ethanol in male and female Sprague-Dawley rats. Animals were gonadectomized, received sham surgery (SH) or non-manipulated (NM) on postnatal (P) day 23 (early) or 67 (late) and tested for CTA to ethanol in adulthood. Water-deprived rats were given 1 hr access every-other-day to 10% sucrose followed by an injection of ethanol (0, 1g/kg) for 5 test sessions. Test data were analyzed to determine the first day significant aversions emerged in each ethanol group (i.e., sucrose intakes significantly less than their saline-injected counterparts). Early gonadectomized males acquired the CTA more rapidly than did early SH and NM males (day 1 vs 3 and 4 respectively), whereas a gonadectomy-associated enhancement in ethanol CTA was not evident in late males. Among females, gonadectomy had little impact on ethanol-induced CTA, with females in all groups showing an aversion by the first or second day, regardless of surgery age. These data suggest that previously observed elevations in ethanol intake induced by either pre- or post-pubertal gonadectomy in males are not related simply to gonadectomy-induced alterations in the aversive effects of ethanol indexed via CTA. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Gaudric, Julien; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Jenny, Catherine; Koskas, Fabien; Chiras, Jacques

    2013-11-01

    The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA.

  5. Clinical evaluation of plasma insulin and C-peptide levels with 3 different high-flux dialyzers in diabetic patients on hemodialysis.

    PubMed

    Abe, M; Okada, K; Maruyama, T; Inoshita, A; Ikeda, K; Uto, E; Kikuchi, F; Matsumoto, K

    2008-10-01

    Changes in plasma immunoreactive insulin (IRI) and connecting-peptide immunoreactivity (CPR) concentrations during hemodialysis (HD) were evaluated in diabetic HD patients with 3 different high-flux membranes. The removal properties of the membranes were compared. In this prospective controlled study, 15 stable diabetic patients on HD were randomly selected for 6 HD sessions with 3 different membranes: polysulfone (PS), cellulose triacetate (CTA), and polymethylmethacrylate (PMMA). Blood samples were obtained from the blood tubing at the arterial (A) site at the beginning and end of the sixth HD session. At 60 minutes after dialysis initiation, blood samples were obtained from both the A and venous (V) sites of the dialyzer to investigate the clearance and removal properties of the membranes. The plasma IRI and CPR levels decreased significantly at each time point with all 3 membranes. IRI clearance with the PS membrane was significantly higher than that with the CTA and PMMA membranes. No difference was observed in the IRI reduction rate between the 3 membranes. CPR clearance and reduction rate with the PMMA membrane were lower than with the PS and CTA membranes. No significant difference was observed in serum creatinine clearance and reduction rates between the 3 membranes; however, serum urea nitrogen clearance was significantly lower with the PMMA membrane compared with the PS and CTA membranes. A significantly high beta2-microglobulin clearance and reduction rate was achieved in the order PS > CTA > PMMA. Plasma IRI and CPR are cleared by HD; their clearance rates differ with the dialyzer membranes. Plasma IRI clearance with the PS membrane is higher than that with the CTA and PMMA membranes.

  6. Increase of glucocorticoids is not required for the acquisition, but hinders the extinction, of lithium-induced conditioned taste aversion.

    PubMed

    Kim, Kyu-Nam; Kim, Bom-Taeck; Kim, Young-Sang; Lee, Jong-Ho; Jahng, Jeong Won

    2014-05-05

    Lithium chloride at doses sufficient to induce conditioned taste aversion (CTA) causes c-Fos expression in the paraventricular nucleus and increases the plasma level of corticosterone with activation of the hypothalamic-pituitary-adrenal axis. This study was conducted to define the role of glucocorticoid in the acquisition and extinction of lithium-induced CTA. In experiment 1, Sprague-Dawley rats received dexamethasone (2mg/kg) or RU486 (20mg/kg) immediately after 5% sucrose access, and then an intraperitoneal injection of isotonic lithium chloride (12ml/kg) was followed with 30min interval. Rats had either 1 or 7 days of recovery period before the daily sucrose drinking tests. In experiment 2, rats were conditioned with the sucrose-lithium pairing, and then received dexamethasone or vehicle at 30min before each drinking test. In experiment 3, adrenalectomized (ADX or ADX+B) rats were subjected to sucrose drinking tests after the sucrose-lithium pairing. Dexamethasone, but not RU486, pretreatment blunted the formation of lithium-induced CTA memory. Dexamethasone prior to each drinking test suppressed sucrose consumption and prolonged the extinction of lithium-induced CTA. Sucrose consumption was significantly suppressed not only in ADX+B rats but also in ADX rats during the first drinking session; however, a significant decrease was found only in ADX rats on the fourth drinking session. These results reveal that glucocorticoid is not a necessary component in the acquisition, but an important player in the extinction, of lithium-induced CTA, and suggest that a pulse increase of glucocorticoid may hinder the extinction memory formation of lithium-induced CTA. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. COMPARISON BETWEEN COMPUTED TOMOGRAPHIC ARTHROGRAPHY, RADIOGRAPHY, ULTRASONOGRAPHY, AND ARTHROSCOPY FOR THE DIAGNOSIS OF FEMOROTIBIAL JOINT DISEASE IN WESTERN PERFORMANCE HORSES.

    PubMed

    Nelson, Brad B; Kawcak, Chris E; Goodrich, Laurie R; Werpy, Natasha M; Valdés-Martínez, Alejandro; McIlwraith, C Wayne

    2016-07-01

    The femorotibial joints are a common source of lameness in Western performance horses. The objective of this prospective study was to compare the radiography, ultrasonography, computed tomographic arthrography (CTA), and arthroscopy findings in horses with lameness localized to the femorotibial joints. Twenty-five stifles in 24 horses were included and were evaluated with all four of these diagnostic methods. Defects detected in femorotibial joint structures were compared between diagnostic methods using a McNemar's test to evaluate for disagreement. Cranial medial meniscotibial desmopathy was most detected on arthroscopy (in 14/25 cases) and was only detected on ultrasonography in three out of 11 (27.3%) arthroscopically observed cases, but was detected on CTA in nine out of 12 (75%) arthroscopically observed cases. Medial meniscal injury located on the craniolateral border was most detected on arthroscopy (n = 9) and was detected on CTA in five cases, but on ultrasonography in 0 cases. Detection of articular cartilage defects on the medial femoral condyle was most detected with arthroscopy (24/25, 96% cases) and was also detected on CTA in 12/20 (60%) cases with a significant disagreement identified between modalities (P = 0.02). Cranial and caudal cruciate ligament defects were detected on CTA in 6/22 (27.3%) and 7/19 (36.8%) cases, respectively, and with arthroscopy in 3/25 (12%) and 2/25 (8%) cases, respectively. The use of CTA detected more defects in the cruciate ligaments, proximal tibia, and ligament entheses than the other diagnostic methods, but was not reliable for detection of articular cartilage damage on the medial femoral condyle. © 2016 American College of Veterinary Radiology.

  8. Rationale and design of the PREDICT (Plaque Registration and Evaluation Detected In Computed Tomography) registry.

    PubMed

    Yamamoto, Hideya; Awai, Kazuo; Kuribayashi, Sachio; Kihara, Yasuki

    2014-01-01

    At least two-thirds of cases of acute coronary syndrome are caused by disruption of an atherosclerotic plaque. The natural history of individual plaques is unknown and needs to be established. The Plaque Registration and Evaluation Detected In Computed Tomography (PREDICT) registry is a prospective, multicenter, longitudinal, observational registry. This registry was designed to examine the relationships among coronary CT angiography (CTA) findings and clinical findings, mortality, and morbidity. The relationships among progression of coronary atherosclerosis, including changes in plaque characteristics on coronary CTA, and serum lipid levels and modification of coronary risk factors will also be evaluated. From October 2009 to December 2012, 3015 patients who underwent coronary CTA in 29 centers in Japan were enrolled. These patients were followed for 2 years. The primary end points were considered as all-cause mortality and major cardiac events, including cardiac death, nonfatal myocardial infarction, and unstable angina that required hospitalization. The secondary end points were heart failure that required administration of diuretics, target vessel revascularization, cerebral infarction, peripheral arterial disease, and invasive coronary angiography. Blood pressure, serum lipid, and C-reactive protein levels and all cardiovascular events were recorded at 1 and 2 years. If the initial coronary CTA showed any stenosis or plaques, follow-up coronary CTA was scheduled at 2 years to determine changes in coronary lesions, including changes in plaque characteristics. Analysis of the PREDICT registry data will clarify the relationships between coronary CTA findings and cardiovascular mortality and morbidity in a collaborative multicenter fashion. This trial is registered at www.clinicaltrials.gov as NCT 00991835. Copyright © 2014 Society of Cardiovascular Computed Tomography. All rights reserved.

  9. Vertebrobasilar system computed tomographic angiography in central vertigo

    PubMed Central

    Paşaoğlu, Lale

    2017-01-01

    Abstract The incidence of vertigo in the population is 20% to 30% and one-fourth of the cases are related to central causes. The aim of this study was to evaluate computed tomography angiography (CTA) findings of the vertebrobasilar system in central vertigo without stroke. CTA and magnetic resonance images of patients with vertigo were retrospectively evaluated. One hundred twenty-nine patients suspected of having central vertigo according to history, physical examination, and otological and neurological tests without signs of infarction on diffusion-weighted magnetic resonance imaging were included in the study. The control group included 120 patients with similar vascular disease risk factors but without vertigo. Vertebral and basilar artery diameters, hypoplasias, exit-site variations of vertebral artery, vertebrobasilar tortuosity, and stenosis of ≥50% detected on CTA were recorded for all patients. Independent-samples t test was used in variables with normal distribution, and Mann–Whitney U test in non-normal distribution. The difference of categorical variable distribution according to groups was analyzed with χ2 and/or Fisher exact test. Vertebral artery hypoplasia and ≥50% stenosis were seen more often in the vertigo group (P = 0.000, <0.001). Overall 78 (60.5%) vertigo patients had ≥50% stenosis, 54 (69.2%) had stenosis at V1 segment, 9 (11.5%) at V2 segment, 2 (2.5%) at V3 segment, and 13 (16.6%) at V4 segment. Both vertigo and control groups had similar basilar artery hypoplasia and ≥50% stenosis rates (P = 0.800, >0.05). CTA may be helpful to clarify the association between abnormal CTA findings of vertebral arteries and central vertigo. This article reveals the opportunity to diagnose posterior circulation abnormalities causing central vertigo with a feasible method such as CTA. PMID:28328808

  10. Vertebrobasilar system computed tomographic angiography in central vertigo.

    PubMed

    Paşaoğlu, Lale

    2017-03-01

    The incidence of vertigo in the population is 20% to 30% and one-fourth of the cases are related to central causes. The aim of this study was to evaluate computed tomography angiography (CTA) findings of the vertebrobasilar system in central vertigo without stroke.CTA and magnetic resonance images of patients with vertigo were retrospectively evaluated. One hundred twenty-nine patients suspected of having central vertigo according to history, physical examination, and otological and neurological tests without signs of infarction on diffusion-weighted magnetic resonance imaging were included in the study. The control group included 120 patients with similar vascular disease risk factors but without vertigo. Vertebral and basilar artery diameters, hypoplasias, exit-site variations of vertebral artery, vertebrobasilar tortuosity, and stenosis of ≥50% detected on CTA were recorded for all patients. Independent-samples t test was used in variables with normal distribution, and Mann-Whitney U test in non-normal distribution. The difference of categorical variable distribution according to groups was analyzed with χ and/or Fisher exact test.Vertebral artery hypoplasia and ≥50% stenosis were seen more often in the vertigo group (P = 0.000, <0.001). Overall 78 (60.5%) vertigo patients had ≥50% stenosis, 54 (69.2%) had stenosis at V1 segment, 9 (11.5%) at V2 segment, 2 (2.5%) at V3 segment, and 13 (16.6%) at V4 segment. Both vertigo and control groups had similar basilar artery hypoplasia and ≥50% stenosis rates (P = 0.800, >0.05).CTA may be helpful to clarify the association between abnormal CTA findings of vertebral arteries and central vertigo.This article reveals the opportunity to diagnose posterior circulation abnormalities causing central vertigo with a feasible method such as CTA.

  11. Communication and coordination demands of railroad roadway worker activities and implications for new technology

    DOT National Transportation Integrated Search

    2007-11-01

    This report documents the results of a cognitive task analysis (CTA) that examined the cognitive and collaborative demands and : activities of railroad roadway workers. The purpose of the CTA of roadway workers was to understand the factors that comp...

  12. Evaluation of the strength of cement-treated aggregate for pavement bases.

    DOT National Transportation Integrated Search

    2006-01-01

    Cement-treated aggregate (CTA) is commonly used to provide a stable base for pavements that are placed over weak soil subgrades. Because CTA reduces the thickness of the aggregate required to provide a durable base by approximately one-half, using it...

  13. Pedestrian/bicyclist warning devices and signs at CTA rail-highway grade crossings.

    DOT National Transportation Integrated Search

    2015-12-14

    The focus of this research was on individuals who utilize legally authorized CTA highway-rail crossings with pedestrian access. While trespassing is a major public safety issue, it is not the focus of this research. : An extensive review of the liter...

  14. Assessing the teaching of procedural skills: can cognitive task analysis add to our traditional teaching methods?

    PubMed

    Sullivan, Maura E; Ortega, Adrian; Wasserberg, Nir; Kaufman, Howard; Nyquist, Julie; Clark, Richard

    2008-01-01

    The purpose of this study was to determine if a cognitive task analysis (CTA) could capture steps and decision points that were not articulated during traditional teaching of a colonoscopy. Three expert colorectal surgeons were videotaped performing a colonoscopy. After the videotapes were transcribed, the experts participated in a CTA. A 26-step procedural checklist and a 16-step cognitive demands table was created by using information obtained in the CTA. The videotape transcriptions were transposed onto the procedural checklist and cognitive demands table to identify steps and decision points that were omitted during traditional teaching. Surgeon A described 50% of "how-to" steps and 43% of decision points. Surgeon B described 30% of steps and 25% of decisions. Surgeon C described 26% of steps and 38% of cognitive decisions. By using CTA, we were able to identify relevant steps and decision points that were omitted during traditional teaching by all 3 experts.

  15. Sensitivity of the Cherenkov Telescope Array to the detection of a dark matter signal in comparison to direct detection and collider experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balazs, Csaba; Conrad, Jan; Farmer, Ben

    Imaging atmospheric Cherenkov telescopes (IACTs) that are sensitive to potential γ-ray signals from dark matter (DM) annihilation above ~50 GeV will soon be superseded by the Cherenkov Telescope Array (CTA). CTA will have a point source sensitivity an order of magnitude better than currently operating IACTs and will cover a broad energy range between 20 GeV and 300 TeV. Using effective field theory and simplified models to calculate γ-ray spectra resulting from DM annihilation, we compare the prospects to constrain such models with CTA observations of the Galactic center with current and near-future measurements at the Large Hadron Collider (LHC)more » and direct detection experiments. Here, for DM annihilations via vector or pseudoscalar couplings, CTA observations will be able to probe DM models out of reach of the LHC, and, if DM is coupled to standard fermions by a pseudoscalar particle, beyond the limits of current direct detection experiments.« less

  16. Sensitivity of the Cherenkov Telescope Array to the detection of a dark matter signal in comparison to direct detection and collider experiments

    DOE PAGES

    Balazs, Csaba; Conrad, Jan; Farmer, Ben; ...

    2017-10-04

    Imaging atmospheric Cherenkov telescopes (IACTs) that are sensitive to potential γ-ray signals from dark matter (DM) annihilation above ~50 GeV will soon be superseded by the Cherenkov Telescope Array (CTA). CTA will have a point source sensitivity an order of magnitude better than currently operating IACTs and will cover a broad energy range between 20 GeV and 300 TeV. Using effective field theory and simplified models to calculate γ-ray spectra resulting from DM annihilation, we compare the prospects to constrain such models with CTA observations of the Galactic center with current and near-future measurements at the Large Hadron Collider (LHC)more » and direct detection experiments. Here, for DM annihilations via vector or pseudoscalar couplings, CTA observations will be able to probe DM models out of reach of the LHC, and, if DM is coupled to standard fermions by a pseudoscalar particle, beyond the limits of current direct detection experiments.« less

  17. 17 CFR 240.17Ad-21T - Operational capability in a Year 2000 environment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... cessation or transfer of these functions. (e)(1)(i) If you are a registered non-bank transfer agent that has... every registered non-bank transfer agent that uses computers in the conduct of its business as a...., Washington, DC 20549-6628 Attention: Y2K Compliance. (d)(1) If you are a registered non-bank transfer agent...

  18. Pre-procedural assessment of aortic annulus dimensions for transcatheter aortic valve replacement: comparison of a non-contrast 3D MRA protocol with contrast-enhanced cardiac dual-source CT angiography.

    PubMed

    Ruile, Philipp; Blanke, Philipp; Krauss, Tobias; Dorfs, Stephan; Jung, Bernd; Jander, Nikolaus; Leipsic, Jonathon; Langer, Mathias; Neumann, Franz-Josef; Pache, Gregor

    2016-04-01

    To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  19. Outcomes of anatomical versus functional testing for coronary artery disease.

    PubMed

    Douglas, Pamela S; Hoffmann, Udo; Patel, Manesh R; Mark, Daniel B; Al-Khalidi, Hussein R; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J; Fordyce, Christopher B; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S; Krucoff, Mitchell W; Malhotra, Vinay; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Yow, Eric; Cooper, Lawton S; Lee, Kerry L

    2015-04-02

    Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P=0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P=0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute; PROMISE ClinicalTrials.gov number, NCT01174550.).

  20. Preoperative computed tomography angiography for planning DIEP flap breast reconstruction reduces operative time and overall complications

    PubMed Central

    Rozen, Warren Matthew; Chowdhry, Muhammad; Band, Bassam; Ramakrishnan, Venkat V.; Griffiths, Matthew

    2016-01-01

    Background The approach and operative techniques associated with breast reconstruction have steadily been refined since its inception, with abdominal perforator-based flaps becoming the gold standard reconstructive option for women undergoing breast cancer surgery. The current study comprises a cohort of 632 patients, in whom specific operative times are recorded by a blinded observer, and aims to address the potential benefits seen with the use of computer tomography (CT) scanning preoperatively on operative outcomes, complications and surgical times. Methods A prospectively recorded, retrospective review was undertaken of patients undergoing autologous breast reconstruction with a DIEP flap at the St Andrews Centre over a 4-year period from 2010 to 2014. Computed tomography angiography (CTA) scanning of patients began in September 2012 and thus 2 time periods were compared: 2 years prior to the use of CTA scans and 2 years afterwards. For all patients, key variables were collected including patient demographics, operative times, flap harvest time, pedicle length, surgeon experience and complications. Results In group 1, comprising patients within the period prior to CTA scans, 265 patients underwent 312 flaps; whilst in group 2, the immediately following 2 years, 275 patients had 320 flaps. The use of preoperative CTA scans demonstrated a significant reduction in flap harvest time of 13 minutes (P<0.013). This significant time saving was seen in all flap modifications: unilateral, bilateral and bipedicled DIEP flaps. The greatest time saving was seen in bipedicle flaps, with a 35-minute time saving. The return to theatre rate significantly dropped from 11.2% to 6.9% following the use of CTA scans, but there was no difference in the total failure rate. Conclusions The study has demonstrated both a benefit to flap harvest time as well as overall operative times when using preoperative CTA. The use of CTA was associated with a significant reduction in complications requiring a return to theatre in the immediate postoperative period. Modern scanners and techniques can reduce the level of ionising radiation, facilitating patients being able to benefit from the advantages that this preoperative planning can convey. PMID:27047777

  1. Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease

    PubMed Central

    Douglas, Pamela S.; Hoffmann, Udo; Patel, Manesh R.; Mark, Daniel B.; Al-Khalidi, Hussein R.; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J.; Fordyce, Christopher B.; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S.; Krucoff, Mitchell W.; Malhotra, Vinay; Picard, Michael H.; Udelson, James E.; Velazquez, Eric J.; Yow, Eric; Cooper, Lawton S.; Lee, Kerry L.

    2015-01-01

    BACKGROUND Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. METHODS We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. RESULTS The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P = 0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P = 0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). CONCLUSIONS In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute; PROMISE ClinicalTrials.gov number, NCT01174550.) PMID:25773919

  2. Liposome encapsulation of chelating agents

    DOEpatents

    Rahman, Yueh Erh

    1976-01-13

    A method for transferring a chelating agent across a cellular membrane by encapsulating the charged chelating agent within liposomes and carrying the liposome-encapsulated chelating agent to the cellular membrane where the liposomes containing the chelating agent will be taken up by the cells, thereby transferring the chelating agent across the cellular membrane. A chelating agent can be introduced into the interior of a cell of a living organism wherein the liposomes will be decomposed, releasing the chelating agent to the interior of the cell. The released chelating agent will complex intracellularly deposited toxic heavy metals, permitting the more soluble metal complex to transfer across the cellular membrane from the cell and subsequently be removed from the living organism.

  3. Prototyping the graphical user interface for the operator of the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Sadeh, I.; Oya, I.; Schwarz, J.; Pietriga, E.

    2016-07-01

    The Cherenkov Telescope Array (CTA) is a planned gamma-ray observatory. CTA will incorporate about 100 imaging atmospheric Cherenkov telescopes (IACTs) at a Southern site, and about 20 in the North. Previous IACT experiments have used up to five telescopes. Subsequently, the design of a graphical user interface (GUI) for the operator of CTA involves new challenges. We present a GUI prototype, the concept for which is being developed in collaboration with experts from the field of Human-Computer Interaction (HCI). The prototype is based on Web technology; it incorporates a Python web server, Web Sockets and graphics generated with the d3.js Javascript library.

  4. Optimization of image quality in pulmonary CT angiography with low dose of contrast material

    NASA Astrophysics Data System (ADS)

    Assi, Abed Al Nasser; Abu Arra, Ali

    2017-06-01

    Aim: The aim of this study was to compare objective image quality data for patient pulmonary embolism between a conventional pulmonary CTA protocol with respect to a novel acquisition protocol performed with optimize radiation dose and less amount of iodinated contrast medium injected to the patients during PE scanning. Materials and Methods: Sixty- four patients with Pulmonary Embolism (PE) possibility, were examined using angio-CT protocol. Patients were randomly assigned to two groups: A (16 women and 16 men, with age ranging from 19-89 years) mean age, 62 years with standard deviation 16; range, 19-89 years) - injected contrast agent: 35-40 ml. B (16 women and 16 men, with age ranging from 28-86 years) - injected contrast agent: 70-80 ml. Other scanning parameters were kept constant. Pulmonary vessel enhancement and image noise were quantified; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective vessel contrast was assessed by two radiologists in consensus. Result: A total of 14 cases of PE (22 %) were found in the evaluated of subjects (nine in group A, and five in group B). All PE cases were detected by the two readers. There was no significant difference in the size or location of the PEs between the two groups, the average image noise was 14 HU for group A and 19 HU for group B. The difference was not statistically significant (p = 0.09). Overall, the SNR and CNR were slightly higher on group B (24.4 and 22.5 respectively) compared with group A (19.4 and 16.4 respectively), but those differences were not statistically significant (p = 0.71 and p = 0.35, respectively). Conclusion and Discussion: Both groups that had been evaluated by pulmonary CTA protocol allow similar image quality to be achieved as compared with each other's, with optimize care dose for both protocol and contrast volume were reduced by 50 % in new protocol comparing to the conventional protocol.

  5. 76 FR 16843 - Order Cancelling Registrations of Certain Transfer Agents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-64102] Order Cancelling Registrations of Certain Transfer Agents March 21, 2011. On November 4, 2010, notice was published in the Federal Register... transfer agents.\\2\\ For the reasons discussed below, the Commission is cancelling the registration of the...

  6. 77 FR 59225 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-26

    ...-17) requires approximately 477 registered transfer agents to conduct searches using third party... agencies with monitoring transfer agents and ensuring compliance with the rule. We estimate that the average number of hours necessary for each transfer agent to comply with Rule 17Ad-17 is five hours...

  7. Methods for Conducting Cognitive Task Analysis for a Decision Making Task.

    DTIC Science & Technology

    1996-01-01

    Cognitive task analysis (CTA) improves traditional task analysis procedures by analyzing the thought processes of performers while they complete a...for using these methods to conduct a CTA for domains which involve critical decision making tasks in naturalistic settings. The cognitive task analysis methods

  8. Initial screening test for blunt cerebrovascular injury: Validity assessment of whole-body computed tomography.

    PubMed

    Laser, Adriana; Kufera, Joseph A; Bruns, Brandon R; Sliker, Clint W; Tesoriero, Ronald B; Scalea, Thomas M; Stein, Deborah M

    2015-09-01

    Our whole-body computed tomography protocol (WBCT), used to image patients with polytrauma, consists of a noncontrast head computed tomography (CT) followed by a multidetector computed tomography (40- or 64- slice) that includes an intravenous, contrast-enhanced scan from the face through the pelvis. WBCT is used to screen for blunt cerebrovascular injury (BCVI) during initial CT imaging of the patient with polytrauma and allows for early initiation of therapy with the goal of avoiding stroke. WBCT has not been directly compared with CT angiography (CTA) of the neck as a screening tool for BCVI. We hypothesize that WBCT is a valid modality to diagnose BCVI compared with neck CTA, thus screening patients with polytrauma for BCVI and limiting the need for subsequent CTA. A retrospective review of the trauma registry was conducted for all patients diagnosed with BCVI from June 2009 to June 2013 at our institution. All injuries, identified and graded on initial WBCT, were compared with neck CTA imaging performed within the first 72 hours. Sensitivity was calculated for WBCT by the use of CTA as the reference standard. Proportions of agreement also were calculated between the grades of injury for both imaging modalities. A total of 319 injured vessels were identified in 227 patients. On initial WBCT 80 (25%) of the injuries were grade I, 75 (24%) grade II, 45 (14%) grade III, 41 (13%) grade IV, and 58 (18%) were classified as indeterminate: 27 vertebral and 31 carotid lesions. Twenty (6%) of the 319 injuries were not detected on WBCT but identified on subsequent CTA (9 grade I, 7 grade II, 4 grade III); 6 vertebral and 14 carotid. For each vessel type and for all vessels combined, WBCT demonstrated sensitivity rates of over 90% to detect BCVI among the population of patients with at least one vessel injured. There was concordant grading of injuries between WBCT and initial diagnostic CTA in 154 (48% of all injuries). Lower grade injures were more discordant than higher grades (55% vs 13%, respectively; P < .001). Grading was upgraded 8% of the time and downgraded 25%. WBCT holds promise as a rapid screening test for BCVI in the patient with polytrauma to identify injuries in the early stage of the trauma evaluation, thus allowing more rapid initiation of treatment. In addition, in those patients with high risk for BCVI but whose WBCT results are negative for BCVI, neck CTA should be considered to more confidently exclude low-grade injuries. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Sex differences in the effects of ethanol pre-exposure during adolescence on ethanol-induced conditioned taste aversion in adult rats

    PubMed Central

    Sherrill, Luke K.; Berthold, Claire; Koss, Wendy A.; Juraska, Janice M.; Gulley, Joshua M.

    2011-01-01

    Alcohol use, which typically begins during adolescence and differs between males and females, is influenced by both the rewarding and aversive properties of the drug. One way adolescent alcohol use may modulate later consumption is by reducing alcohol s aversive properties. Here, we used a conditioned taste aversion (CTA) paradigm to determine if pre-exposure to alcohol (ethanol) during adolescence would attenuate ethanol-induced CTA assessed in adulthood in a sex-dependent manner. Male and female Long-Evans rats were given intraperitoneal (i.p.) injections of saline or 3.0 g/kg ethanol in a binge-like pattern during postnatal days (PD) 35–45. In adulthood (> PD 100), rats were given access to 0.1% saccharin, followed by saline or ethanol (1.0 or 1.5 g/kg, i.p.), over four conditioning sessions. We found sex differences in ethanol-induced CTA, with males developing a more robust aversion earlier in conditioning. Sex differences in the effects of pre-exposure were also evident: males, but not females, showed an attenuated CTA in adulthood following ethanol pre-exposure, which occurred approximately nine weeks earlier. Taken together, these findings indicate that males are more sensitive to the aversive properties of ethanol than females. In addition, the ability of pre-exposure to the ethanol US to attenuate CTA is enhanced in males compared to females. PMID:21767576

  10. Evaluation of novel PMTs of worldwide best parameters for the CTA project

    NASA Astrophysics Data System (ADS)

    Mirzoyan, R.; Müller, D.; Hose, J.; Menzel, U.; Nakajima, D.; Takahashi, M.; Teshima, M.; Toyama, T.; Yamamoto, T.

    2017-02-01

    Photomultiplier Tubes (PMT) are the most widespread detectors for measuring fast and faint light signals. About six years ago, we started an improvement program for the PMT candidates for the Cherenkov Telescope Array (CTA) project in cooperation with the companies Hamamatsu Photonics K.K. (Japan) and Electron Tubes Enterprises Ltd. (England). CTA is the next major Imaging Atmospheric Cherenkov Telescopes array for ground-based high energy gamma-ray astrophysics. A total of ∼ 100 telescopes of sizes of 23 m, 12 m and 4 m in diameter will be built in northern and southern hemispheres. For CTA we need PMTs with the highest quantum efficiency and photoelectron collection efficiency, short pulse width of a few ns, low transit time spread and very low afterpulsing. The manufacturers were able to produce 1.5‧ PMTs of enhanced peak quantum efficiency of ∼ 40 % . These collect up to 95-98% of photoelectrons onto the first dynode for the wavelengths ≥ 400 nm . A pulse width of ≤ 3 ns has been achieved at the selected operational gain of 40k. The afterpulsing for a threshold of ≥ 4 photoelectrons is dramatically reduced, down to the level of 0.02%. We will report on the measurements of 1.5‧ PMTs from Hamamatsu and Electron Tubes Enterprises as candidate PMTs for the CTA project. The novel 1.5‧ PMTs have the worldwide best parameters.

  11. 17 CFR 240.17Ad-21T - Operational capability in a Year 2000 environment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... cessation or transfer of these functions. (e)(1)(i) If you are a registered non-bank transfer agent that has... to every registered non-bank transfer agent that uses computers in the conduct of its business as a...., Washington, DC 20549-6628 Attention: Y2K Compliance. (d)(1) If you are a registered non-bank transfer agent...

  12. 17 CFR 240.17Ad-21T - Operational capability in a Year 2000 environment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... cessation or transfer of these functions. (e)(1)(i) If you are a registered non-bank transfer agent that has... to every registered non-bank transfer agent that uses computers in the conduct of its business as a...., Washington, DC 20549-6628 Attention: Y2K Compliance. (d)(1) If you are a registered non-bank transfer agent...

  13. 17 CFR 240.17Ad-21T - Operational capability in a Year 2000 environment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... cessation or transfer of these functions. (e)(1)(i) If you are a registered non-bank transfer agent that has... to every registered non-bank transfer agent that uses computers in the conduct of its business as a...., Washington, DC 20549-6628 Attention: Y2K Compliance. (d)(1) If you are a registered non-bank transfer agent...

  14. 75 FR 68012 - Notice of Intention To Cancel Registrations of Certain Transfer Agents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-04

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-63211] Notice of Intention To Cancel Registrations of Certain Transfer Agents October 29, 2010. Notice is hereby given that the Securities and... Securities Exchange Act of 1934 (``Act''),\\1\\ cancelling the registrations of the transfer agents whose names...

  15. 78 FR 4768 - Lost Securityholders and Unresponsive Payees

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-23

    ... 17Ad-17, ``Transfer Agents' Obligation to Search for Lost Securityholders'' to: extend the requirements of Rule 17Ad-17 to search for lost securityholders from only recordkeeping transfer agents to brokers... requirement that recordkeeping transfer agents search for ``lost securityholders.'' \\5\\ \\4\\ 17 CFR 240.17Ad-17...

  16. 76 FR 70516 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... Budget for extension and approval. Rule 17Ad-6 requires every registered transfer agent to make and keep... taken to perform transfer agent activities (to ensure compliance with the minimum performance standards... appointment or termination of the transfer agent; (4) stop orders or notices of adverse claims to the...

  17. 77 FR 38865 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ...) (17 CFR 240.17Ad-4) is used to document when transfer agents are exempt, or no longer exempt, from the minimum performance standards and certain recordkeeping provisions of the Commission's transfer agent rules. Rule 17Ad-4(c) sets forth the conditions under which a registered transfer agent loses its exempt...

  18. Comparative Cognitive Task Analysis

    DTIC Science & Technology

    2007-01-01

    is to perform a task analyses to determine how people operate in a specific domain on a specific task. Cognitive Task Analysis (CTA) is a set of...accomplish a task. In this chapter, we build on CTA methods by suggesting that comparative cognitive task analysis (C2TA) can help solve the aforementioned

  19. Exploiting Tumor-Activated Testes Proteins to Enhance Efficacy of First-Line Chemotherapeutics in NSCLC

    DTIC Science & Technology

    2015-10-01

    TERMS Cancer Testis Antigen (CTA), Fanconia- Anemia (FA), DNA Damage, Genomic Instability, DNA Double Strand Break (DSB) 16. SECURITY CLASSIFICATION OF...Cancer Testis Antigen (CTA) o Fanconia- Anemia (FA) o DNA Damage o Genomic Instability o DNA Double Strand Break (DSB) 3. Accomplishments • What

  20. Noise Assessment of the Chicago Transit Authority Rail Rapid Transit System

    DOT National Transportation Integrated Search

    1979-01-01

    The report describes the noise on and near the Chicago Transit Authority (CTA) urban rail transit lines. The CTA urban rail lines consist of approximately 86 miles of two-way revenue track (of which 9.6 miles are in subway) and 155 stations. Noise da...

  1. Barrier to Success: Community College Students Critical Thinking Skills.

    ERIC Educational Resources Information Center

    Pearson, Charlene V.

    In 1991, a study was conducted using the Watson-Glaser Critical Thinking Appraisal (CTA) to determine how well students at Rancho Santiago College (RSC), a large, multicultural community institution in Santa Ana, California, demonstrated critical thinking abilities. Written at the ninth grade reading level, the CTA attempts to assess an…

  2. Conversion of the CTA, Inc., en route operations concepts database into a formal sentence outline job task taxonomy.

    DOT National Transportation Integrated Search

    1993-01-01

    FAA Air Traffic Control Operations Concepts Volume VI: ARTCC-Host En Route Controllers (1990) developed by CTA, Inc., a technical description of the duties of an En Route air traffic control specialist (ATCS), formatted in User Interface Language, wa...

  3. The recent NIR Flare of the Blazar CTA102

    NASA Astrophysics Data System (ADS)

    Carrasco, L.; Escobedo, G.; Porras, A.; Recillas, E.; Chavushyan, V.; Mayya, D. Y.

    2018-01-01

    Following the report of increased Gamma-Ray activity detected by AGILE of the high redshift QSO (z=1.037) CTA102 cross identified with the radio source 4C+11.69 and the Gamma-ray source 2FGLJ2232.4+1143 by Lucarelli et al.(ATEL #11045).

  4. 64-Slice Computed Tomographic Angiography for the Diagnosis of Intermediate Risk Coronary Artery Disease

    PubMed Central

    2010-01-01

    Executive Summary In July 2009, the Medical Advisory Secretariat (MAS) began work on Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease (CAD), an evidence-based review of the literature surrounding different cardiac imaging modalities to ensure that appropriate technologies are accessed by patients suspected of having CAD. This project came about when the Health Services Branch at the Ministry of Health and Long-Term Care asked MAS to provide an evidentiary platform on effectiveness and cost-effectiveness of non-invasive cardiac imaging modalities. After an initial review of the strategy and consultation with experts, MAS identified five key non-invasive cardiac imaging technologies for the diagnosis of CAD. Evidence-based analyses have been prepared for each of these five imaging modalities: cardiac magnetic resonance imaging, single photon emission computed tomography, 64-slice computed tomographic angiography, stress echocardiography, and stress echocardiography with contrast. For each technology, an economic analysis was also completed (where appropriate). A summary decision analytic model was then developed to encapsulate the data from each of these reports (available on the OHTAC and MAS website). The Non-Invasive Cardiac Imaging Technologies for the Diagnosis of Coronary Artery Disease series is made up of the following reports, which can be publicly accessed at the MAS website at: www.health.gov.on.ca/mas or at www.health.gov.on.ca/english/providers/program/mas/mas_about.html Single Photon Emission Computed Tomography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Stress Echocardiography with Contrast for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis 64-Slice Computed Tomographic Angiography for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Cardiac Magnetic Resonance Imaging for the Diagnosis of Coronary Artery Disease: An Evidence-Based Analysis Pease note that two related evidence-based analyses of non-invasive cardiac imaging technologies for the assessment of myocardial viability are also available on the MAS website: Positron Emission Tomography for the Assessment of Myocardial Viability: An Evidence-Based Analysis Magnetic Resonance Imaging for the Assessment of Myocardial Viability: an Evidence-Based Analysis The Toronto Health Economics and Technology Assessment Collaborative has also produced an associated economic report entitled: The Relative Cost-effectiveness of Five Non-invasive Cardiac Imaging Technologies for Diagnosing Coronary Artery Disease in Ontario [Internet]. Available from: http://theta.utoronto.ca/reports/?id=7 Objective The objective of this report is to determine the accuracy of computed tomographic angiography (CTA) compared to the more invasive option of coronary angiography (CA) in the detection of coronary artery disease (CAD) in stable (non-emergent) symptomatic patients. CT Angiography CTA is a cardiac imaging test that assesses the presence or absence, as well as the extent, of coronary artery stenosis for the diagnosis of CAD. As such, it is a test of cardiac structure and anatomy, in contrast to the other cardiac imaging modalities that assess cardiac function. It is, however, unclear as to whether cardiac structural features alone, in the absence cardiac function information, are sufficient to determine the presence or absence of intermediate pretest risk of CAD. CTA technology is changing rapidly with increasing scan speeds and anticipated reductions in radiation exposure. Initial scanners based on 4, 8, 16, 32, and 64 slice machines have been available since the end of 2004. Although 320-slice machines are now available, these are not widely diffused and the existing published evidence is specific to 64-slice scanners. In general, CTA allows for 3-dimensional (3D) viewing of the coronary arteries derived from software algorithms of 2-dimensional (2D) images. The advantage of CTA over CA, the gold standard for the diagnosis of CAD, is that it is relatively less invasive and may serve as a test in determining which patients are best suited for a CA. CA requires insertion of a catheter through an artery in the arm or leg up to the area being studied, yet both tests involve contrast agents and radiation exposure. Therefore, the identification of patients for whom CTA or CA is more appropriate may help to avoid more invasive tests, treatment delays, and unnecessary radiation exposure. The main advantage of CA, however, is that treatment can be administered in the same session as the test procedure and as such, it’s recommended for patients with a pre-test probability of CAD of ≥80%. The progression to the more invasive CA allows for the diagnosis and treatment in one session without the added radiation exposure from a previous CTA. The visibility of arteries in CTA images is best in populations with a disease prevalence, or pre-test probabilities of CAD, of 40% to 80%, beyond which patients are considered at high pre-test probability. Visibility decreases with increasing prevalence as arteries become increasingly calcified (coronary artery calcification is based on the Agaston score). Such higher risk patients are not candidates for the less invasive diagnostic procedures and should proceed directly to CA, where treatment can be administered in conjunction with the test itself, while bypassing the radiation exposure from CTA. CTA requires the addition of an ionated contrast, which can be administered only in patients with sufficient renal function (creatinine levels >30 micromoles/litre) to allow for the clearing of the contrast from the body. In some cases, the contrast is administered in patients with creatinine levels less than 30 micromoles/litre. A second important criterion for the administration of the CTA is patient heart rate, which should be less than 65 beats/min for the single source CTA machines and less than 80 beats/min for the dual source machines. To decrease heart rates to these levels, beta-blockers are often required. Although the accuracy of these two machines does not differ, the dual source machines can be utilized in a higher proportion of patients than the single source machines for patients with heart beats of up to 80 beats/min. Approximately 10% of patients are considered ineligible for CTA because of this inability to decrease heart rates to the required levels. Additional contra-indications include renal insufficiency as described above and atrial fibrillation, with approximately 10% of intermediate risk patients ineligible for CTA due these contraindications. The duration of the procedure may be between 1 and 1.5 hours, with about 15 minutes for the CTA and the remaining time for the preparation of the patient. CTA is licensed by Health Canada as a Class III device. Currently, two companies have licenses for 64-slice CT scanners, Toshiba Medical Systems Corporation (License 67604) and Philips Medical Systems (License 67599 and 73260). Research Questions How does the accuracy of CTA compare to the more invasive CA in the diagnosis of CAD in symptomatic patients at intermediate risk of the disease? How does the accuracy for CTA compare to other modalities in the detection of CAD? Research Methods Literature Search A literature search was performed on July 20, 2009 using OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), the Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) for studies published from January 1, 2004 until July 20, 2009. Abstracts were reviewed by a single reviewer and, for those studies meeting the eligibility criteria, full-text articles were obtained. Reference lists were also examined for any relevant studies not identified through the search. The quality of evidence was assessed as high, moderate, low or very low according to GRADE methodology. Inclusion Criteria English language articles and English or French-language HTAs published from January 1, 2004 to July 20, 2009. Randomized controlled trials (RCTs), non-randomized clinical trials, systematic reviews and meta-analyses. Studies of symptomatic patients at intermediate pre-test probability of CAD. Studies of single source CTA compared to CA for the diagnosis of CAD. Studies in which sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) could be established. HTAs, SRs, clinical trials, observational studies. Exclusion Criteria Non-English studies. Pediatric populations. Studies of patients at low or high pre-test probability of CAD. Studies of unstable patients, e.g., emergency room visits, or a prior diagnosis of CAD. Studies in patients with non-ischemic heart disease. Studies in which outcomes were not specific to those of interest in this report. Studies in which CTA was not compared to CA in a stable population. Outcomes of Interest) CAD defined as ≥50% stenosis. Comparator Coronary angiography. Measures of Interest Sensitivity, specificity; Negative predictive value (NPV), positive predictive value (PPV); Area under the curve (AUC) and diagnostic odds ratios (DOR). Results of Literature Search and Evidence-Based Analysis The literature search yielded two HTAs, the first published by MAS in April 2005, the other from the Belgian Health Care Knowledge Centre published in 2008, as well as three recent non-randomized clinical studies. The three most significant studies concerning the accuracy of CTA versus CA are the CORE-64 study, the ACCURACY trial, and a prospective, multicenter, multivendor study conducted in the Netherlands. Five additional non-randomized studies were extracted from the Belgian Health Technology Assessment (2008). To provide summary estimates of sensitivity, specificity, area under the SROC curve (AUC) and diagnostic odds rations (DORs), a meta-analysis of the above-mentioned studies was conducted. Pooled estimates of sensitivity and specificity were 97.7% (95%CI: 95.5% - 99.9%) and 78.8% (95%CI: 70.8% - 86.8%), respectively. These results indicate that the sensitivity of CTA is almost as good as CA, while its specificity is poorer. The diagnostic odds ratio (DOR) was estimated at 157.0 (95%CI: 11.2 - 302.7) and the AUC was found to be 0.94; however, the inability to provide confidence estimates for this estimate decreased its utility as an adequate outcome measure in this review. This meta-analysis was limited by the significant heterogeneity between studies for both the pooled sensitivity and specificity (heterogeneity Chi-square p=0.000). To minimize these statistical concerns, the analysis was restricted to studies of intermediate risk patients with no previous history of cardiac events. Nevertheless, the underlying prevalence of CAD ranged from 24.8% to 78% between studies, indicating that there was still some variability in the pre-test probabilities of disease within this stable population. The variation in the prevalence of CAD, accompanied with differences in the proportion of calcification, likely affected the specificity directly and the sensitivity indirectly across studies. In February 2010, the results of the Ontario Multi-detector Computed Tomography Coronary Angiography Study (OMCAS) became available and were thus included in a second meta-analysis of the above studies. The OMCAS was a non-randomized double-blind study conducted in 3 centers in Ontario that was conducted as a result of a MAS review from 2005 requesting an evaluation of the accuracy of 64-slice CTA for CAD detection. Within 10 days of their scheduled CA, all patients received an additional evaluation with CTA. Included in the meta-analysis with the above-mentioned studies are 117 symptomatic patients with intermediate probability of CAD (10% - 90% probability), resulting in a pooled sensitivity of 96.1% (95%CI: 94.0%-98.3%) and pooled specificity of 81.5% (95%CI: 73.0% - 89.9%). Summary of Findings CTA is almost as good as CA in detecting true positives but poorer in the rate of false positives. The main value of CTA may be in ruling out significant CAD. Increased prevalence of CAD decreases study specificity, whereas specificity is increased in the presence of increased arterial calcification even in lower prevalence studies. Positive CT angiograms may require additional tests such as stress tests or the more invasive CA, partly to identify false positives. Radiation exposure is an important safety concern that needs to be considered, particularly the cumulative exposures from repeat CTAs. PMID:23074388

  5. 17 CFR 240.17Ad-17 - Transfer agents' obligation to search for lost securityholders.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., each recordkeeping transfer agent shall conduct two data base searches using at least one information data base service. The transfer agent shall search by taxpayer identification number or by name if a.... Such data base searches must be conducted without charge to a lost securityholder and with the...

  6. 17 CFR 240.17Ad-17 - Transfer agents' obligation to search for lost securityholders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., each recordkeeping transfer agent shall conduct two data base searches using at least one information data base service. The transfer agent shall search by taxpayer identification number or by name if a.... Such data base searches must be conducted without charge to a lost securityholder and with the...

  7. 17 CFR 240.17Ad-17 - Transfer agents' obligation to search for lost securityholders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., each recordkeeping transfer agent shall conduct two data base searches using at least one information data base service. The transfer agent shall search by taxpayer identification number or by name if a.... Such data base searches must be conducted without charge to a lost securityholder and with the...

  8. The Oxidation of Terminal Alkenes by Permanganate: A Practical Demonstration of the Use of Phase Transfer Agents.

    ERIC Educational Resources Information Center

    Brown, Keith C.; And Others

    1982-01-01

    Use of phase transfer agents to facilitate/accelerate chemical reactions has become an established practice, particularly in organic chemistry. Describes an undergraduate laboratory procedure demonstrating the principles involved in the use of said agents. Includes student results from phase transfer assisted permanganate oxidations. (Author/JN)

  9. Dorsal medial prefrontal cortex contributes to conditioned taste aversion memory consolidation and retrieval.

    PubMed

    Gonzalez, Maria Carolina; Villar, Maria Eugenia; Igaz, Lionel M; Viola, Haydée; Medina, Jorge H

    2015-12-01

    The medial prefrontal cortex (mPFC) is known for its role in decision making and memory processing, including the participation in the formation of extinction memories. However, little is known regarding its contribution to aversive memory consolidation. Here we demonstrate that neural activity and protein synthesis are required in the dorsal mPFC for memory formation of a conditioned taste aversion (CTA) task and that this region is involved in the retrieval of recent and remote long-term CTA memory. In addition, both NMDA receptor and CaMKII activity in dorsal mPFC are needed for CTA memory consolidation, highlighting the complexity of mPFC functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Conditioned taste aversion induced by motion is prevented by selective vagotomy in the rat

    NASA Technical Reports Server (NTRS)

    Fox, Robert A.; Mckenna, Susan

    1991-01-01

    The role of the vagus nerve in motion-induced conditioned taste aversion (CTA) was studied in hooded rats. Animals with complete, selective gastric vagotomy failed to form conditioned taste aversion after multiple conditioning sessions in which the conditioned stimulus (a cider vinegar solution) was drunk immediately before a 30-min exposure to vertical axis rotation at 150 deg/s. Results are discussed with reference to the use of CTA as a measure of motion-induced 'sickness' or gastrointestinal disturbance, and because motion-induced CTA requires that both the vagus nerve and the vestibular apparatus be intact, in light of the possible convergence of vegal and vestibular functions.

  11. Applying Cognitive Work Analysis to Time Critical Targeting Functionality

    DTIC Science & Technology

    2004-10-01

    Cognitive Task Analysis , CTA, Cognitive Task Analysis , Human Factors, GUI, Graphical User Interface, Heuristic Evaluation... Cognitive Task Analysis MITRE Briefing January 2000 Dynamic Battle Management Functional Architecture 3-1 Section 3 Human Factors...clear distinction between Cognitive Work Analysis (CWA) and Cognitive Task Analysis (CTA), therefore this document will refer to these

  12. 78 FR 58362 - Consolidated Tape Association; Notice of Filing of the Eighteenth Substantive Amendment to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-70428; File No. SR-CTA-2013-05] Consolidated...''),\\1\\ and Rule 608 thereunder,\\2\\ notice is hereby given that on September 9, 2013, the Consolidated... Securities and Exchange Commission (``Commission'') a proposal to amend the Second Restatement of the CTA...

  13. The Use of Cognitive Task Analysis to Capture Expertise for Tracheal Extubation Training in Anesthesiology

    ERIC Educational Resources Information Center

    Embrey, Karen K.

    2012-01-01

    Cognitive task analysis (CTA) is a knowledge elicitation technique employed for acquiring expertise from domain specialists to support the effective instruction of novices. CTA guided instruction has proven effective in improving surgical skills training for medical students and surgical residents. The standard, current method of teaching clinical…

  14. Is Cognitive Test-Taking Anxiety Associated With Academic Performance Among Nursing Students?

    PubMed

    Duty, Susan M; Christian, Ladonna; Loftus, Jocelyn; Zappi, Victoria

    2016-01-01

    The cognitive component of test anxiety was correlated with academic performance among nursing students. Modest but statistically significant lower examination grade T scores were observed for students with high compared with low levels of cognitive test anxiety (CTA). High levels of CTA were associated with reduced academic performance.

  15. Integrated studies on the use of cognitive task analysis to capture surgical expertise for central venous catheter placement and open cricothyrotomy.

    PubMed

    Yates, Kenneth; Sullivan, Maura; Clark, Richard

    2012-01-01

    Cognitive task analysis (CTA) methods were used for 2 surgical procedures to determine (1) the extent that experts omitted critical information, (2) the number of experts required to capture the optimalamount of information, and (3) the effectiveness of a CTA-informed curriculum. Six expert physicians for both the central venous catheter placement and open cricothyrotomy were interviewed. The transcripts were coded, corrected, and aggregated as a "gold standard." The information captured for each surgeon was then analyzed against the gold standard. Experts omitted an average of 34% of the decisions for the central venous catheter and 77% of the decisions for the Cric. Three to 4 experts were required to capture the optimal amount of information. A significant positive effect on performance (t([21]) = 2.08, P = .050), and self-efficacy ratings (t([18]) = 2.38, P = .029) were found for the CTA-informed curriculum for cricothyrotomy. CTA is an effective method to capture expertise in surgery and a valuable component to improve surgical training. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Reducing radiation dose without compromising image quality in preoperative perforator flap imaging with CTA using ASIR technology.

    PubMed

    Niumsawatt, Vachara; Debrotwir, Andrew N; Rozen, Warren Matthew

    2014-01-01

    Computed tomographic angiography (CTA) has become a mainstay in preoperative perforator flap planning in the modern era of reconstructive surgery. However, the increased use of CTA does raise the concern of radiation exposure to patients. Several techniques have been developed to decrease radiation dosage without compromising image quality, with varying results. The most recent advance is in the improvement of image reconstruction using an adaptive statistical iterative reconstruction (ASIR) algorithm. We sought to evaluate the image quality of ASIR in preoperative deep inferior epigastric perforator (DIEP) flap surgery, through a direct comparison with conventional filtered back projection (FBP) images. A prospective review of 60 consecutive ASIR and 60 consecutive FBP CTA images using similar protocol (except for radiation dosage) was undertaken, analyzed by 2 independent reviewers. In both groups, we were able to accurately identify axial arteries and their perforators. Subjective analysis of image quality demonstrated no statistically significant difference between techniques. ASIR can thus be used for preoperative imaging with similar image quality to FBP, but with a 60% reduction in radiation delivery to patients.

  17. 75 FR 13146 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... Office of Management and Budget for extension and approval. Rule 17Ad-10 requires registered transfer... for which it performs transfer agent functions, including the purchase, transfer and redemptions of securities. In addition, the rule also requires transfer agents that maintain securityholder records to...

  18. Preparation and Cross-Linking of All-Acrylamide Diblock Copolymer Nano-Objects via Polymerization-Induced Self-Assembly in Aqueous Solution

    PubMed Central

    2017-01-01

    Various carboxylic acid-functionalized poly(N,N-dimethylacrylamide) (PDMAC) macromolecular chain transfer agents (macro-CTAs) were chain-extended with diacetone acrylamide (DAAM) by reversible addition–fragmentation chain transfer (RAFT) aqueous dispersion polymerization at 70 °C and 20% w/w solids to produce a series of PDMAC–PDAAM diblock copolymer nano-objects via polymerization-induced self-assembly (PISA). TEM studies indicate that a PDMAC macro-CTA with a mean degree of polymerization (DP) of 68 or higher results in the formation of well-defined spherical nanoparticles with mean diameters ranging from 40 to 150 nm. In contrast, either highly anisotropic worms or polydisperse vesicles are formed when relatively short macro-CTAs (DP = 40–58) are used. A phase diagram was constructed to enable accurate targeting of pure copolymer morphologies. Dynamic light scattering (DLS) and aqueous electrophoresis studies indicated that in most cases these PDMAC–PDAAM nano-objects are surprisingly resistant to changes in either solution pH or temperature. However, PDMAC40–PDAAM99 worms do undergo partial dissociation to form a mixture of relatively short worms and spheres on adjusting the solution pH from pH 2–3 to around pH 9 at 20 °C. Moreover, a change in copolymer morphology from worms to a mixture of short worms and vesicles was observed by DLS and TEM on heating this worm dispersion to 50 °C. Postpolymerization cross-linking of concentrated aqueous dispersions of PDMAC–PDAAM spheres, worms, or vesicles was performed at ambient temperature using adipic acid dihydrazide (ADH), which reacts with the hydrophobic ketone-functionalized PDAAM chains. The formation of hydrazone groups was monitored by FT-IR spectroscopy and afforded covalently stabilized nano-objects that remained intact on exposure to methanol, which is a good solvent for both blocks. Rheological studies indicated that the cross-linked worms formed a stronger gel compared to linear precursor worms. PMID:28260814

  19. Synthesis and application of a new carboxylated cellulose derivative. Part I: Removal of Co(2+), Cu(2+) and Ni(2+) from monocomponent spiked aqueous solution.

    PubMed

    Teodoro, Filipe Simões; Ramos, Stela Nhandeyara do Carmo; Elias, Megg Madonyk Cota; Mageste, Aparecida Barbosa; Ferreira, Gabriel Max Dias; da Silva, Luis Henrique Mendes; Gil, Laurent Frédéric; Gurgel, Leandro Vinícius Alves

    2016-12-01

    A new carboxylated cellulose derivative (CTA) was prepared from the esterification of cellulose with 1,2,4-Benzenetricarboxylic anhydride. CTA was characterized by percent weight gain (pwg), amount of carboxylic acid groups (nCOOH), elemental analysis, FTIR, TGA, solid-state (13)C NMR, X-ray diffraction (DRX), specific surface area, pore size distribution, SEM and EDX. The best CTA synthesis condition yielded a pwg and nCOOH of 94.5% and 6.81mmolg(-1), respectively. CTA was used as an adsorbent material to remove Co(2+), Cu(2+) and Ni(2+) from monocomponent spiked aqueous solution. Adsorption studies were developed as a function of the solution pH, contact time and initial adsorbate concentration. Langmuir model better fitted the experimental adsorption data and the maximum adsorption capacities estimated by this model were 0.749, 1.487 and 1.001mmolg(-1) for Co(2+), Cu(2+) and Ni(2+), respectively. The adsorption mechanism was investigated by using isothermal titration calorimetry. The values of ΔadsH° were in the range from 5.36 to 8.09kJmol(-1), suggesting that the mechanism controlling the phenomenon is physisorption. Desorption and re-adsorption studies were also performed. Desorption and re-adsorption efficiencies were closer to 100%, allowing the recovery of both metal ions and CTA adsorbent. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Transient inhibition of protein synthesis in the rat insular cortex delays extinction of conditioned taste aversion with cyclosporine A.

    PubMed

    Hadamitzky, Martin; Orlowski, Kathrin; Schwitalla, Jan Claudius; Bösche, Katharina; Unteroberdörster, Meike; Bendix, Ivo; Engler, Harald; Schedlowski, Manfred

    2016-09-01

    Conditioned responses gradually weaken and eventually disappear when subjects are repeatedly exposed to the conditioned stimulus (CS) in the absence of the unconditioned stimulus (US), a process called extinction. Studies have demonstrated that extinction of conditioned taste aversion (CTA) can be prevented by interfering with protein synthesis in the insular cortex (IC). However, it remained unknown whether it is possible to pharmacologically stabilize the taste aversive memory trace over longer periods of time. Thus, the present study aimed at investigating the time frame during which extinction of CTA can be efficiently prevented by blocking protein synthesis in the IC. Employing an established conditioning paradigm in rats with saccharin as CS, and the immunosuppressant cyclosporine A (CsA) as US, we show here that daily bilateral intra-insular injections of the protein synthesis inhibitor anisomycin (120μg/μl) immediately after retrieval significantly diminished CTA extinction over a period of five retrieval days and subsequently reached levels of saline-infused controls. These findings demonstrate that it is possible to efficiently delay but not to fully prevent CTA extinction during repeated retrieval trials by blocking protein translation with daily bilateral infusions of anisomycin in the IC. These data confirm and extent earlier reports indicating that the role of protein synthesis in CTA extinction learning is not limited to gastrointestinal malaise-inducing drugs such as lithium chloride (LiCl). Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Evaluation of radiation dose of triple rule-out coronary angiography protocols with different scan length using 256-slice CT

    NASA Astrophysics Data System (ADS)

    Tsai, Chia-Jung; Lee, Jason J. S.; Chen, Liang-Kuang; Mok, Greta S. P.; Hsu, Shih-Ming; Wu, Tung-Hsin

    2011-10-01

    Triple rule-out coronary CT angiography (TRO-CTA) is a new approach for providing noninvasive visualization of coronary arteries with simultaneous evaluation of pulmonary arteries, thoracic aorta and other intrathoracic structures. The increasing use of TRO-CTA examination with longer scan length is associated with the concerns about radiation dose and their corresponding cancer risk. The purpose of this study is to evaluate organ dose and effective dose for the TRO-CTA examination with 2 scan lengths: TRO std and TRO ext, using 256-slice CT. TRO-CTA examinations were performed on a 256-slice CT scanner without ECG-based tube current modulation. Absorbed organ doses were measured using an anthropomorphic phantom and thermal-luminance dosimeters (TLDs). Effective dose was determined by taking a sum of the measured absorbed organ doses multiplied with the tissue weighting factor based on ICRP-103, and compared to that calculated using the dose-length product (DLP) method. We obtained high organ doses in the thyroid, esophagus, breast, heart and lung in both TRO-CTA protocols. Effective doses of the TRO std and TRO ext protocols with the phantom method were 26.37 and 42.49 mSv, while those with the DLP method were 19.68 and 38.96 mSv, respectively. Our quantitative dose information establishes a relationship between radiation dose and scanning length, and can provide a practical guidance to best clinical practice.

  2. CT angiography in the setting of suspected acute mesenteric ischemia: prevalence of ischemic and alternative diagnoses.

    PubMed

    Henes, Frank Oliver; Pickhardt, Perry J; Herzyk, Andrzej; Lee, Scott J; Motosugi, Utaroh; Derlin, Thorsten; Lubner, Meghan G; Adam, Gerhard; Schön, Gerhard; Bannas, Peter

    2017-04-01

    The purpose of the study was to determine the prevalence of ischemic and alternative diagnoses and the diagnostic accuracy of CT angiography (CTA) in the setting of suspected acute mesenteric ischemia (AMI). We included 959 patients undergoing CTA for the evaluation of suspected AMI. The final clinical diagnosis was used to determine the prevalence of ischemic and alternative diagnoses and to calculate the diagnostic accuracy of CTA. Prevalence of diagnoses by age, sex, and admission status was compared using Cochran-Armitage and χ 2 tests. Prevalence was 18.8% (180/959) for AMI and 61.2% (587/959) for specific alternative diagnoses. In the remaining 20.0% (192/959), no clear clinical diagnosis was established. The most frequent alternative diagnoses were small-bowel obstruction (10.4%; 61/587), infectious colitis (8.7%; 51/587), pneumonia (6.5%; 38/587), cholecystitis (6.1%; 36/587), and diverticulitis (5.6%; 33/587). Prevalence of specific alternative diagnoses varied significantly according to both age (p < .013) and admissions status (p < 0.001). CTA had a sensitivity and specificity for diagnosing AMI of 89.4%/99.5% and for alternative diagnoses of 86.7%/96.9%, respectively. In the setting of suspected AMI, the prevalence of ischemic and alternative diagnoses varies significantly by age, sex, and admission status. CTA provides for rapid and non-invasive assessment of ischemic and alternative diagnoses with high diagnostic accuracy.

  3. Sex differences in the effects of ethanol pre-exposure during adolescence on ethanol-induced conditioned taste aversion in adult rats.

    PubMed

    Sherrill, Luke K; Berthold, Claire; Koss, Wendy A; Juraska, Janice M; Gulley, Joshua M

    2011-11-20

    Alcohol use, which typically begins during adolescence and differs between males and females, is influenced by both the rewarding and aversive properties of the drug. One way adolescent alcohol use may modulate later consumption is by reducing alcohol's aversive properties. Here, we used a conditioned taste aversion (CTA) paradigm to determine if pre-exposure to alcohol (ethanol) during adolescence would attenuate ethanol-induced CTA assessed in adulthood in a sex-dependent manner. Male and female Long-Evans rats were given intraperitoneal (i.p.) injections of saline or 3.0g/kg ethanol in a binge-like pattern during postnatal days (PD) 35-45. In adulthood (>PD 100), rats were given access to 0.1% saccharin, followed by saline or ethanol (1.0 or 1.5g/kg, i.p.), over four conditioning sessions. We found sex differences in ethanol-induced CTA, with males developing a more robust aversion earlier in conditioning. Sex differences in the effects of pre-exposure were also evident: males, but not females, showed an attenuated CTA in adulthood following ethanol pre-exposure, which occurred approximately nine weeks earlier. Taken together, these findings indicate that males are more sensitive to the aversive properties of ethanol than females. In addition, the ability of pre-exposure to the ethanol US to attenuate CTA is enhanced in males compared to females. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Dynamic Computed Tomography Angiography: Role in the Evaluation of Popliteal Artery Entrapment Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anil, Gopinathan, E-mail: ivyanil10@gmail.com; Tay, Kiang-Hiong; Howe, Tse-Chiang

    2011-04-15

    This study reviews our experience with dynamic computed tomographic angiography (CTA) as an imaging modality in the evaluation of popliteal artery entrapment syndrome (PAES). Eight patients with surgically proven PAES were included in this study. Dynamic CTA studies performed with the feet in neutral and plantar flexed positions were reviewed for the detailed anatomy of the region and to define the location and extent of the stenosis, occlusions and collateral circulation. These findings were compared with intraoperative observations. CTA provided adequate angiographic and anatomic information required to arrive at the diagnosis and make a surgical decision. Thirteen limbs were affectedmore » in eight patients. There was popliteal artery occlusion in four limbs, stenosis at rest that was accentuated on stress imaging in two limbs, and patent popliteal artery with marked stenosis on stress imaging in seven limbs. Long-segment stenosis was seen in functional entrapment compared to short-segment stenosis in anatomic PAES. Anteroposterior compression of the popliteal artery in anatomic PAES unlike the side-to-side compression in functional PAES was a unique observation in this study. The CTA and surgical characterisation and classification of PAES matched in all the patients, except for misinterpretation of compressing fibrous bands as accessory slips of muscles in three limbs. In conclusion, dynamic CTA is a robust diagnostic tool that provides clinically relevant information and serves as a rapidly performed and easily available 'one-stop-shop' imaging modality in the management of PAES.« less

  5. [Values of computed tomography angiogram in non-cardiac surgery planning and cardiac risk assessment of coronary atherosclerosis during perioperative period].

    PubMed

    Chang, Rui-ping; Ju, Hai-yue; Zhang, Xing-hua; Wu, Jian; Zhang, Fan; Mi, Wei-dong; Cao, Xiu-tang; Gao, Chang-qing; Yang, Li

    2013-02-19

    To explore the values of detecting coronary atherosclerosis by computed tomography angiogram (CTA) on non-cardiac surgery planning and cardiac risk assessment of coronary atherosclerosis during perioperative period. A total of 89 patients with suspected coronary heart disease (CHD) scheduled for non-cardiac surgery underwent coronary CTA to evaluate luminal stenosis and calculate calcification score. There were 56 males and 33 females with a mean age of 65.1 years. Operative sites included chests (n = 29), abdomens and pelvis (n = 26), large vessels (n = 3), bones and joints (n = 19) and other regions (n = 12). Reasons of abandoned or postponed surgery were documented to analyze the influence of CTA results on surgery planning. Cardiac events were recorded to assess the correlation with coronary atherosclerosis. Among them, 75 patients (84.27%) were diagnosed as atherosclerosis while 10 patients (11.24%) were negative; 2 patients had coronary artery bypass and another 2 had stent implantation. According to the results of CTA, 12 operations (13.48%) were canceled and 8 (8.98%) postponed after interventions. Severe stenosis of coronary lumen had significant effects on surgery planning (P = 0.003) while calcification score did not. In patients undergoing surgery as scheduled or after intervention, 1 had atrial fibrillation at post-operation. For the patients with suspected CHD scheduled for non-cardiac surgery, severity of coronary stenosis may greatly influence surgery planning. Preoperative coronary CTA may decrease the incidence of cardiac events during perioperative period.

  6. Occurrence of spot signs from hypodensity areas on precontrast CT in intracerebral hemorrhage.

    PubMed

    Nishiyama, Jun; Sorimachi, Takatoshi; Aoki, Rie; Inoue, Go; Matsumae, Mitsunori

    2017-05-01

    Both the spot signs, which is a bright spot on computed tomography angiography (CTA) source images, and hypodensity areas within a hematoma on precontrast CT scans, which presumably represent uncoagulated blood, have been reported to be predictive of hematoma enlargement in acute spontaneous intracerebral hematoma (ICH). The aim was to investigate densities on precontrast CT scans in an area within a hematoma that matched the locations of spot signs on CTA source images. In consecutive cases of spontaneous ICH admitted within 6 h after onset, early spot signs on CTA source images and delayed spot signs on delayed-phase CT scans 90 s after CTA were evaluated. Of 177 patients undergoing CTA, 41 (23.2%) showed early spot signs. Among 146 patients who underwent delayed-phase CT scans, 23 (15.8%) demonstrated delayed spot signs but not early spot signs. Spot signs originated from hypodensity areas, including densities <50 HU, in 30 of 35 patients (85.7%) with early spot signs and in 8 of 23 (34.8%) with delayed spot signs. Early spot signs arose from hypodensity areas more frequently than delayed spot signs (p < 0.05). Hematoma enlargement was observed in 10 of 24 patients (41.7%) with early spot signs, but in none with delayed spot signs. Some hypodensity areas within ICHs may indicate uncoagulated blood related to ongoing leakage, which are seen as spot signs. Minimum densities in hypodensity areas might correlate with the speed and volume of bleeding.

  7. Mexican and Mexican American Student Reflections on Transfer: Institutional Agents and the Continued Role of the Community College

    ERIC Educational Resources Information Center

    Cortez, Edén; Castro, Erin L.

    2017-01-01

    This qualitative analysis draws upon the experiences of six Mexican and Mexican American community college transfer students during the 2012-2013 academic year. Relying on literature regarding institutional agents, we examine students' reflections regarding pre- and post-transfer support from both institutional agents and structured student…

  8. 17 CFR 240.17Ad-10 - Prompt posting of certificate detail to master securityholder files, maintenance of accurate...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... between co-transfer agents and recordkeeping transfer agents, maintenance of current control book... Supervised Investment Bank Holding Company Rules § 240.17Ad-10 Prompt posting of certificate detail to master... recordkeeping transfer agents, maintenance of current control book, retention of certificate detail and “buy-in...

  9. Failure to Find Ethanol-Induced Conditioned Taste Aversion in Honey Bees (Apis mellifera L.).

    PubMed

    Varnon, Christopher A; Dinges, Christopher W; Black, Timothy E; Wells, Harrington; Abramson, Charles I

    2018-04-24

    Conditioned taste aversion (CTA) learning is a highly specialized form of conditioning found across taxa that leads to avoidance of an initially neutral stimulus, such as taste or odor, that is associated with, but is not the cause of, a detrimental health condition. This study examines if honey bees (Apis mellifera L.) develop ethanol (EtOH)-induced CTA. Restrained bees were first administered a sucrose solution that was cinnamon scented, lavender scented, or unscented, and contained either 0, 2.5, 5, 10, or 20% EtOH. Then, 30 minutes later, we used a proboscis extension response (PER) conditioning procedure where the bees were taught to associate either cinnamon odor, lavender odor, or an air-puff with repeated sucrose feedings. For some bees, the odor of the previously consumed EtOH solution was the same as the odor associated with sucrose in the conditioning procedure. If bees are able to learn EtOH-induced CTA, they should show an immediate low level of response to odors previously associated with EtOH. We found that bees did not develop CTA despite the substantial inhibitory and aversive effects EtOH has on behavior. Instead, bees receiving a conditioning odor that was previously associated with EtOH showed an immediate high level of response. While this demonstrates bees are capable of one-trial learning common to CTA experiments, this high level of response is the opposite of what would occur if the bees developed a CTA. Responding on subsequent trials also showed a general inhibitory effect of EtOH. Finally, we found that consumption of cinnamon extract reduced the effects of EtOH. The honey bees' lack of learned avoidance to EtOH mirrors that seen in human alcoholism. These findings demonstrate the usefulness of honey bees as an insect model for EtOH consumption. Copyright © 2018 by the Research Society on Alcoholism.

  10. Accuracy of Computed Tomographic Perfusion in Diagnosis of Brain Death: A Prospective Cohort Study.

    PubMed

    Sawicki, Marcin; Sołek-Pastuszka, Joanna; Chamier-Ciemińska, Katarzyna; Walecka, Anna; Bohatyrewicz, Romuald

    2018-05-04

    BACKGROUND This study was designed to determine diagnostic accuracy of computed tomographic perfusion (CTP) compared to computed tomographic angiography (CTA) for the diagnosis of brain death (BD). MATERIAL AND METHODS Whole-brain CTP was performed in patients diagnosed with BD and in patients with devastating brain injury with preserved brainstem reflexes. CTA was derived from CTP datasets. Cerebral blood flow (CBF) and volume (CBV) were calculated in all brain regions. CTP findings were interpreted as confirming diagnosis of BD (positive) when CBF and CBV in all ROIs were below 10 mL/100 g/min and 1.0 mL/100 g, respectively. CTA findings were interpreted using a 4-point system. RESULTS Fifty brain-dead patients and 5 controls were included. In brain-dead patients, CTP results revealed CBF 0.00-9.98 mL/100 g/min and CBV 0.00-0.99 mL/100 g, and were thus interpreted as positive in all patients. CTA results suggested 7 negative cases, providing 86% sensitivity. In the non-brain-dead group, CTP results revealed CBF 2.37-37.59 mL/100 g/min and CBV 0.73-2.34 mL/100 g. The difference between values of CBF and CBV in the brain-dead and non-brain-dead groups was statistically significant (p=0.002 for CBF and p=0.001 for CBV). CTP findings in all non-brain-dead patients were interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTP in the diagnosis of BD. In all non-brain-dead patients, CTA revealed preserved intracranial filling and was interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTA in diagnosis of BD. CONCLUSIONS Whole-brain CTP seems to be a highly sensitive and specific method in diagnosis of BD.

  11. Determination of Endograft Apposition, Position, and Expansion in the Aortic Neck Predicts Type Ia Endoleak and Migration After Endovascular Aneurysm Repair.

    PubMed

    Schuurmann, Richte C L; van Noort, Kim; Overeem, Simon P; van Veen, Ruben; Ouriel, Kenneth; Jordan, William D; Muhs, Bart E; 't Mannetje, Yannick W; Reijnen, Michel M P J; Fioole, Bram; Ünlü, Çağdaş; Brummel, Peter; de Vries, Jean-Paul P M

    2018-06-01

    To describe the added value of determining changes in position and apposition on computed tomography angiography (CTA) after endovascular aneurysm repair (EVAR) to detect early caudal displacement of the device and to prevent type Ia endoleak. Four groups of elective EVAR patients were selected from a dataset purposely enriched with type Ia endoleak and migration (>10 mm) cases. The groups included cases of late type Ia endoleak (n=36), migration (n=9), a type II endoleak (n=16), and controls without post-EVAR complications (n=37). Apposition of the endograft fabric with the aortic neck, shortest distance between the fabric and the renal arteries, expansion of the main body (or dilatation of the aorta in the infrarenal sealing zone), and tilt of the endograft toward the aortic axis were determined on the first postoperative and the last available CTA scan without type Ia endoleak or migration. Differences in these endograft dimensions were compared between the first vs last scan and among the 4 groups. No significant differences in endograft configurations were observed among the groups on the first postoperative CTA scan. On the last CTA scan before a complication arose, the position of the fabric relative to the renal arteries, expansion of the main body, and apposition of the fabric with the aortic neck were significantly different between the type Ia endoleak (median follow-up 15 months) and migration groups (median follow-up 23 months) compared with the control group (median follow-up 19 months). Most endograft dimensions had changed significantly compared with the first postoperative CTA scan for all groups. Apposition had increased in the control group but had decreased significantly in the type Ia endoleak and migration groups. Progressive changes in dimensions of the endograft within the infrarenal neck could be detected on regular CTA scans before the complication became urgent in many patients.

  12. Role of CTA1R7K-COL-DD as a novel therapeutic mucosal tolerance-inducing vector for treatment of collagen-induced arthritis.

    PubMed

    Hasselberg, Annemarie; Schön, Karin; Tarkowski, Andrej; Lycke, Nils

    2009-06-01

    To determine whether a cholera toxin-derived, novel immunomodulating fusion protein, CTA1R7K-COL-DD, carrying the class II major histocompatibility complex H-2q-restricted type II collagen peptide aa 259-274, can induce therapeutic tolerance and prevent collagen-induced arthritis (CIA) when administered intranasally in DBA/1 mice, and to assess whether ADP-ribosylation at the mucosal membranes exerts a regulatory function such that the outcome of tolerance or immune enhancement can be controlled. DBA/1 mice with CIA were treated intranasally with CTA1R7K-COL-DD. The therapeutic effect was monitored for 46 days after the onset of disease. Clinical scoring of disease, histologic examination of inflammation, and bone erosion were assessed, and cytokine levels were determined in the serum or supernatants from splenocytes stimulated with recall antigen. The protective effect of CTA1R7K-COL-DD resulted in roughly 60% of the mice having no clinical signs or histologic evidence of disease after treatment, and those with CIA had significantly milder disease with less bone erosion. The protective status was associated with lower serum titers of IgG1, IgG2a, IgG2b, and IgG3 anticollagen and a substantial decrease in the production of interleukin-6 (IL-6), IL-17, and interferon-gamma, while levels of IL-10 were markedly up-regulated both in the serum and at the T cell level. The enzymatically inactive mutant fusion protein CTA1R7K-COL-DD provided substantial therapeutic protection against CIA following intranasal administration. The mechanism behind the effect appears to be mediated by peptide-specific regulatory T cells induced by mucosal exposure to the peptide containing CTA1R7K-COL-DD vector. In addition, ADP-ribosylation at the mucosal membranes acts as a key regulator controlling mucosal tolerance or immunity.

  13. Reducing Variability in Orthogonal Reformatted Image Quality Associated With Axial Long-z-Axis CT Angiography.

    PubMed

    Stein, Erica B; Liu, Peter S; Kazerooni, Ella A; Barber, Karen; Davenport, Matthew S

    2016-12-01

    The objective of our study was to reduce variation in image quality of orthogonal reformatted images generated from long-z-axis CT angiography (CTA) studies of the upper and lower extremities. Upper and lower extremity CTA studies were targeted at a single health care system. A correctly performed CTA examination was defined as one that met the following three criteria: Sagittal and coronal reformats were obtained, a high-resolution matrix greater than 512 × 512 was used, and reformatted images were available in a distance-measurable format. Baseline data were collected from February 1, 2014, through September 30, 2014. Corrective actions were implemented during three consecutive plan-do-check-act (PDCA) cycles from October 1, 2014, through July 31, 2015, that addressed human, technical, and systematic variations. A 3-month maintenance period followed in which no intervention was performed. Longitudinal data were analyzed monthly using a statistical process control chart (p-chart). The total number of long-z-axis extremity CTA studies analyzed was as follows: 351 CTA studies were analyzed at baseline, 94 at the first PDCA cycle, 92 at the second PDCA cycle, 114 at the third PDCA cycle, and 138 during the maintenance period. The monthly rate of correctly performed studies ranged from 7% to 51% (mean, 38% ± 13% [SD]) during the baseline period, 32-59% (mean, 46% ± 14%) during the first PDCA cycle, 40-81% (mean, 61% ± 21%) during the second PDCA cycle, and 80-82% (mean, 81% ± 0.9%) during the third PDCA cycle. The monthly rate improved to 90-91% (mean, 91% ± 0.5%) during the maintenance period. The upper and lower control limits of the p-chart were upshifted after the second and third PDCA cycles. Correcting systematic and technical variations led to the greatest improvements in reformat accuracy. Obtaining consistently and correctly reformatted images from long-z-axis CTA studies is achievable using iterative PDCA cycles.

  14. Diagnostic accuracy of 64-slice multidetector CT angiography for detection of in-stent restenosis of vertebral artery ostium stents: comparison with conventional angiography.

    PubMed

    Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo

    2014-10-01

    There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Rate of Contrast Extravasation on CT Angiography Predicts Hematoma Expansion and Mortality in Primary Intracerebral Hemorrhage

    PubMed Central

    Brouwers, H. Bart; Battey, Thomas W.K.; Musial, Hayley H.; Ciura, Viesha A.; Falcone, Guido J.; Ayres, Alison M.; Vashkevich, Anastasia; Schwab, Kristin; Viswanathan, Anand; Anderson, Christopher D.; Greenberg, Steven M.; Pomerantz, Stuart R.; Ortiz, Claudia J.; Goldstein, Joshua N.; Gonzalez, R. Gilberto; Rosand, Jonathan; Romero, Javier M.

    2015-01-01

    Background and Purpose In primary intracerebral hemorrhage (ICH), the presence of contrast extravasation following CT angiography (CTA), termed the ‘spot sign’, predicts hematoma expansion and mortality. Since the biological underpinnings of the spot sign are not fully understood, we investigated whether the rate of contrast extravasation - which may reflect the rate of bleeding - predicts expansion and mortality beyond the simple presence of the spot sign. Methods Consecutive ICH patients with first-pass CTA followed by a 90-second delayed post-contrast CT (delayed CTA) were included. CTAs were reviewed for spot sign presence by two blinded readers. Spot sign volumes on first-pass and delayed CTA and ICH volumes were measured using semi-automated software. Extravasation rates were calculated and tested for association with hematoma expansion and mortality using uni- and multivariable logistic regression. Results 162 patients were included, 48 (30%) of whom had ≥1 spot sign. Median spot sign volume was 0.04mL on first-pass CTA and 0.4mL on delayed CTA. Median extravasation rate was 0.23mL/min overall, and 0.30mL/min among expanders versus 0.07mL/min in non-expanders. Extravasation rates were also significantly higher in patients who died in hospital: 0.27mL/min versus 0.04mL/min. In multivariable analysis, the extravasation rate was independently associated with in-hospital mortality (OR1.09 [95%CI 1.04–1.18], p=0.004), 90-day mortality (OR1.15 [95%CI 1.08–1.27], p=0.0004), and hematoma expansion (OR1.03 [95%CI 1.01–1.08], p=0.047). Conclusions Contrast extravasation rate, or spot sign growth, further refines the ability to predict hematoma expansion and mortality. Our results support the hypothesis that the spot sign directly measures active bleeding in acute ICH. PMID:26243220

  16. Rate of Contrast Extravasation on Computed Tomographic Angiography Predicts Hematoma Expansion and Mortality in Primary Intracerebral Hemorrhage.

    PubMed

    Brouwers, H Bart; Battey, Thomas W K; Musial, Hayley H; Ciura, Viesha A; Falcone, Guido J; Ayres, Alison M; Vashkevich, Anastasia; Schwab, Kristin; Viswanathan, Anand; Anderson, Christopher D; Greenberg, Steven M; Pomerantz, Stuart R; Ortiz, Claudia J; Goldstein, Joshua N; Gonzalez, R Gilberto; Rosand, Jonathan; Romero, Javier M

    2015-09-01

    In primary intracerebral hemorrhage, the presence of contrast extravasation after computed tomographic angiography (CTA), termed the spot sign, predicts hematoma expansion and mortality. Because the biological underpinnings of the spot sign are not fully understood, we investigated whether the rate of contrast extravasation, which may reflect the rate of bleeding, predicts expansion and mortality beyond the simple presence of the spot sign. Consecutive intracerebral hemorrhage patients with first-pass CTA followed by a 90-second delayed postcontrast CT (delayed CTA) were included. CTAs were reviewed for spot sign presence by 2 blinded readers. Spot sign volumes on first-pass and delayed CTA and intracerebral hemorrhage volumes were measured using semiautomated software. Extravasation rates were calculated and tested for association with hematoma expansion and mortality using uni- and multivariable logistic regressions. One hundred and sixty-two patients were included, 48 (30%) of whom had ≥1 spot sign. Median spot sign volume was 0.04 mL on first-pass CTA and 0.4 mL on delayed CTA. Median extravasation rate was 0.23 mL/min overall and 0.30 mL/min among expanders versus 0.07 mL/min in nonexpanders. Extravasation rates were also significantly higher in patients who died in hospital: 0.27 mL/min versus 0.04 mL/min. In multivariable analysis, the extravasation rate was independently associated with in-hospital mortality (odds ratio, 1.09 [95% confidence interval, 1.04-1.18], P=0.004), 90-day mortality (odds ratio, 1.15 [95% confidence interval, 1.08-1.27]; P=0.0004), and hematoma expansion (odds ratio, 1.03 [95% confidence interval, 1.01-1.08]; P=0.047). Contrast extravasation rate, or spot sign growth, further refines the ability to predict hematoma expansion and mortality. Our results support the hypothesis that the spot sign directly measures active bleeding in acute intracerebral hemorrhage. © 2015 American Heart Association, Inc.

  17. Prospects for PWNe and SNRs science with the ASTRI mini-array of pre-production small-sized telescopes of the Cherenkov telescope array

    NASA Astrophysics Data System (ADS)

    Burtovoi, A.; Zampieri, L.; Giuliani, A.; Bigongiari, C.; Di Pierro, F.; Stamerra, A.

    2017-01-01

    The development and construction of the Cherenkov Telescope Array (CTA) opens up new opportunities for the study of very high energy (VHE, E > 100 GeV) sources. As a part of CTA, the ASTRI project, led by INAF, has one of the main goals to develop one of the mini-arrays of CTA pre-production telescopes, proposed to be installed at the CTA southern site. Thanks to the innovative dual-mirror optical design of its small-sized telescopes, the ASTRI mini-array will be characterized by a large field of view, an excellent angular resolution and a good sensitivity up to energies of several tens of TeV. Pulsar wind nebulae, along with Supernova Remnants, are among the most abundant sources that will be identified and investigated, with the ultimate goal to move significantly closer to an understanding of the origin of cosmic rays (CR). As part of the ongoing effort to investigate the scientific capabilities for both CTA as a whole and the ASTRI mini-array, we performed simulations of the Vela X region. We simulated its extended VHE γ-ray emission using the results of the detailed H.E.S.S. analysis of this source. We estimated the resolving capabilities of the diffuse emission and the detection significance of the pulsar with both CTA as a whole and the ASTRI mini-array. Moreover with these instruments it will be possible to observe the high-energy end of SNRs spectrum, searching for particles with energies near the cosmic-rays "knee" (E ˜ 1015 eV). We simulated a set of ASTRI mini-array observations for one young and an evolved SNRs in order to test the capabilities of this instrument to discover and study PeVatrons on the Galactic plane.

  18. Computed Tomography Angiography in Patients Evaluated for Acute Pulmonary Embolism with Low Serum D-dimer Levels: A Prospective Study

    PubMed Central

    Gimber, Lana Hirai; Travis, R Ing; Takahashi, Jayme M; Goodman, Torrey L; Yoon, Hyo-Chun

    2009-01-01

    Context: Pulmonary computed tomography angiography (CTA) and the Wells criteria both have interobserver variability in the assessment of pulmonary embolism (PE). Quantitative D-dimer assay findings have been shown to have a high negative predictive value in patients with low pretest probability of PE. Objective: Evaluate roles for clinical probability and CTA in Emergency Department (ED) patients suspected of acute PE but having a low serum D-dimer level. Design: Prospective observational study of ED patients with possible PE who underwent pulmonary CTA and had D-dimer levels ≤1.0 μg/mL. Main Outcome: Clinical probability of PE determined by ED physicians using standard published criteria; pulmonary CTAs read by initial and study radiologists kept unaware of D-dimer results. Results: In 16 months, 744 patients underwent pulmonary CTA, with 347 study participants who had a D-dimer level ≤ 1.0 μg/mL. In one participant, CTA showed a PE that was agreed on by both the initial and study radiologists. In six participants, the initial findings were reported as positive for PE but were not interpreted as positive by the study radiologist. In none of these participants was PE diagnosed on the basis of clinical probability, of findings on ancillary studies and three-month follow-up examination, or by another radiologist, unaware of findings, acting as a tiebreaker. Conclusion: Pulmonary CTA findings positive for acute embolism should be viewed with caution, especially if the suspected PE is in a distal segmental or subsegmental artery in a patient with a serum D-dimer level of ≤1.0 μg/mL. Furthermore, the Wells criteria may be of limited additional value in this group of patients with low D-dimer levels because most will have low or intermediate clinical probability of PE. PMID:20740096

  19. Long-Term Prognostic Value of Coronary CT Angiography in Asymptomatic Type 2 Diabetes Mellitus.

    PubMed

    Kang, Se Hun; Park, Gyung-Min; Lee, Seung-Whan; Yun, Sung-Cheol; Kim, Young-Hak; Cho, Young-Rak; Park, Hyun Woo; Suh, Jon; Yang, Dong Hyun; Kang, Joon-Won; Lim, Tae-Hwan; Jung, Chang Hee; Koh, Eun Hee; Lee, Woo Je; Kim, Min-Seon; Lee, Ki-Up; Park, Joong-Yeol

    2016-11-01

    This study sought to evaluate the long-term prognostic value of coronary computed tomography angiography (CTA) in asymptomatic patients with type 2 diabetes mellitus. There are limited data on the long-term prognostic impact of coronary CTA in asymptomatic patients with type 2 diabetes mellitus. This study analyzed clinical outcomes of 591 consecutive asymptomatic patients with type 2 diabetes mellitus who underwent coronary CTA (mean age 62.2 ± 8.3 years and 352 men [59.6%]). A cardiac event was defined as a composite of cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, or late coronary revascularization. Patients were categorized into 3 groups according to severity of coronary artery disease (CAD) on coronary CTA: normal coronary arteries, nonobstructive CAD (<50%), and obstructive CAD (≥50%). One hundred sixty-eight patients (28.4%) had normal coronary arteries, whereas 236 (39.9%) patients had nonobstructive CAD and 187 (31.6%) had obstructive CAD. During the follow-up period (median 5.3 years [interquartile range: 4.7 to 5.8 years]), 37 cardiac events occurred in 29 patents: 10 cardiac deaths, 2 nonfatal myocardial infarctions, 8 cases of unstable angina, and 17 late coronary revascularizations. The 6-year event-free survival rates were 99.3 ± 0.7% in patients with normal coronary arteries, 96.7 ± 1.2% in patients with nonobstructive CAD, and 86.2 ± 3.0% in patients with obstructive CAD (log-rank p < 0.001). Asymptomatic patients with type 2 diabetes mellitus with normal coronary arteries or nonobstructive CAD on coronary CTA show excellent clinical outcomes over a follow-up period of more than 5 years, whereas prognosis is worse in patients with obstructive CAD. These findings suggest long-term prognostic value of coronary CTA for asymptomatic type 2 diabetes mellitus. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. The Cherenkov Telescope Array production system for Monte Carlo simulations and analysis

    NASA Astrophysics Data System (ADS)

    Arrabito, L.; Bernloehr, K.; Bregeon, J.; Cumani, P.; Hassan, T.; Haupt, A.; Maier, G.; Moralejo, A.; Neyroud, N.; pre="for the"> CTA Consortium, DIRAC Consortium,

    2017-10-01

    The Cherenkov Telescope Array (CTA), an array of many tens of Imaging Atmospheric Cherenkov Telescopes deployed on an unprecedented scale, is the next-generation instrument in the field of very high energy gamma-ray astronomy. An average data stream of about 0.9 GB/s for about 1300 hours of observation per year is expected, therefore resulting in 4 PB of raw data per year and a total of 27 PB/year, including archive and data processing. The start of CTA operation is foreseen in 2018 and it will last about 30 years. The installation of the first telescopes in the two selected locations (Paranal, Chile and La Palma, Spain) will start in 2017. In order to select the best site candidate to host CTA telescopes (in the Northern and in the Southern hemispheres), massive Monte Carlo simulations have been performed since 2012. Once the two sites have been selected, we have started new Monte Carlo simulations to determine the optimal array layout with respect to the obtained sensitivity. Taking into account that CTA may be finally composed of 7 different telescope types coming in 3 different sizes, many different combinations of telescope position and multiplicity as a function of the telescope type have been proposed. This last Monte Carlo campaign represented a huge computational effort, since several hundreds of telescope positions have been simulated, while for future instrument response function simulations, only the operating telescopes will be considered. In particular, during the last 18 months, about 2 PB of Monte Carlo data have been produced and processed with different analysis chains, with a corresponding overall CPU consumption of about 125 M HS06 hours. In these proceedings, we describe the employed computing model, based on the use of grid resources, as well as the production system setup, which relies on the DIRAC interware. Finally, we present the envisaged evolutions of the CTA production system for the off-line data processing during CTA operations and the instrument response function simulations.

  1. Effect of a topical anaesthetic formulation on the cortisol response to surgical castration of unweaned beef calves.

    PubMed

    McCarthy, D; Lomax, S; Windsor, P A; White, P J

    2016-01-01

    Impracticality and cost of existing pain management strategies during surgical castration of beef cattle have limited their widespread implementation on-farm. A farmer-applied topical anaesthetic formulation, originally developed and used commercially to mitigate the pain of mulesing in lambs, was investigated for its potential use for managing pain in surgically castrated calves. This formulation contained lidocaine, bupivacaine, adrenalin and cetrimide. In this study, 24 Angus bull calves were randomly allocated to (1) surgical castration (C, n=8), (2) surgical castration with the post-operative application of topical anaesthetic (CTA, n=8) and (3) sham castration/control (CON, n=8). The experiment was conducted over 2 days, with treatment groups evenly represented across each day. Calves were habituated to handling before the experiment and blood samples were collected for plasma cortisol measurement at defined time periods before, at and post treatment, (at -0.5, 0 h, then +0.5, 1, 1.5, 2, 4 and 6 h). There was a significant effect of time on cortisol concentrations across all treatment groups (P<0.01), with lowest concentrations at -0.5 and 6 h and peak concentration at 0.5 h being significantly higher than the cortisol response at 0 h. The effect of treatment was not significant (P=0.077), however, there was a trend for CON calves to display lower cortisol concentrations than C and CTA calves and CTA calves to display lower cortisol concentrations than C calves. The mean area under the curve (AUC) of CON calves was significantly lower than those of C and CTA calves (P=0.04), however, there was no significant difference between the AUCs of CTA and C calves. Immediate application of topical anaesthetic after surgical castration did not significantly reduce plasma cortisol concentrations. However, the trend for CTA calves to display lower cortisol concentrations than C calves warrants further investigation into the use of TA for pain relief of surgically castrated beef calves.

  2. Highly Sensitive Troponin I Followed by Advanced Coronary Artery Disease Assessment Using Computed Tomography Angiography Improves Acute Coronary Syndrome Risk Stratification Accuracy and Work-up in Acute Chest Pain Patients: Results from ROMICAT II Trial

    PubMed Central

    Mayrhofer, Thomas; Puchner, Stefan B.; Lu, Michael T.; Maurovich-Horvat, Pal; Pope, J. Hector; Truong, Quynh A.; Udelson, James E.; Peacock, W. Frank; White, Charles S.; Woodard, Pamela K.; Fleg, Jerome L.; Nagurney, John T.; Januzzi, James L.; Hoffmann, Udo

    2015-01-01

    Objectives We compared diagnostic accuracy of conventional troponin/traditional coronary artery disease (CAD) assessment and highly sensitive troponin (hsTn) I/advanced CAD assessment for acute coronary syndrome (ACS) during the index hospitalization. Background HsTn I and advanced assessment of CAD using coronary computed tomography angiography (CTA) are promising candidates to improve the accuracy of emergency department (ED) evaluation of patients with suspected ACS. Methods We performed an observational cohort study in patients with suspected ACS enrolled in the ROMICAT II trial and randomized to coronary CTA who also had hsTn I measurement at the time of the ED presentation. We assessed coronary CTA for traditional (no CAD, non-obstructive CAD, ≥50% stenosis) and advanced features of CAD (≥50% stenosis, high-risk plaque features: positive remodeling, low <30 Hounsfield Units plaque, napkin ring sign, spotty calcium). Results Of 160 patients (mean age: 53±8 years, 40% women) 10.6% were diagnosed with ACS. The ACS rate in patients with HsTn I below the limit of detection (n=9, 5.6%), intermediate (n=139, 86.9%), and above the 99th percentile (n=12, 7.5%) was 0%, 8.6%, and 58.3%, respectively. Absence of ≥50% stenosis and high-risk plaque ruled out ACS in patients with intermediate hsTn I (n=87, 54.4%; ACS rate 0%), while patients with both ≥50% stenosis and high-risk plaque were at high risk (n=13, 8.1%; ACS rate 69.2%) and patients with either ≥50% stenosis or high-risk plaque were at intermediate risk for ACS (n=39, 24.4%; ACS rate 7.7%). HsTn I/advanced coronary CTA assessment significantly improved the diagnostic accuracy for ACS as compared to conventional troponin/traditional coronary CTA (AUC 0.84, 95%CI 0.80-0.88 vs. 0.74, 95%CI 0.70-0.78; p<0.001). Conclusions HsTn I at the time of presentation followed by early advanced coronary CTA assessment improves the risk stratification and diagnostic accuracy for ACS as compared to conventional troponin and traditional coronary CTA assessment. (Multicenter Study to Rule Out Myocardial Infarction/Ischemia by Cardiac Computed Tomography [ROMICAT-II]; NCT01084239) PMID:26476506

  3. An imaging anatomical study on percutaneous kyphoplasty for lumbar via a unilateral transverse process-pedicle approach.

    PubMed

    Wang, Song; Wang, Qing; Kang, Jianping; Xiu, Peng; Wang, Gaoju

    2014-04-20

    An imaging anatomical measurement. To investigate the anatomical feasibility of percutaneous kyphoplasty for lumbar osteoporotic vertebral compression fractures via a unilateral transverse process-pedicle approach (TPA). Kyphoplasty via a unilateral approach has been reported and good clinical results have been achieved. However, because of the lack of an anatomical study, these approaches have yet to be popularized. A total of 150 lumbar vertebral bodies of 30 patients were simulated kyphoplasty on the computed tomographic scans through conventional transpedicle approach (CTA) and the TPA, respectively. Anatomical parameters including the distance between the entry point and the midline of the vertebral body, the puncture inclination angle, and the success rate of puncture were measured and compared. The distance between the entry point and the midline from L1 to L5 lumbar levels varied from 20.6 ± 2.2 mm to 28.6 ± 2.9 mm in the CTA group and from 23.6 ± 2.2 mm to 33.6 ± 2.9 mm in the TPA group. The entry point from L1 to L5 in the TPA group was 3.0 ± 2.1 mm to 5.1 ± 2.7 mm more lateral than that in the CTA group. The medial inclination angles from L1 to L5 were 30.2° ± 6.4° to 47.7° ± 5.4° in the TPA and 15.3° ± 6.0° to 22.8° ± 8.7° in the CTA group. The inclination angles in the TPA group were greater than that in the CTA group and the safe range of the puncture angles was also wider. The success rate was 51.7% in the CTA group and 87.7% in the TPA group. The entry point through a TPA was localized at the midline of the transverse process, 3.0 to 5.1 mm outside the lateral margin of the pedicle projection. Compared with CTA, the puncture inclination angle in the TPA approach was much larger with a wider safe puncture range. The TPA approach allowed an easy puncture to meet or surpass the midline of the lumbar vertebral body. N/A.

  4. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    PubMed

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p < 0.0001). Higher scores were associated with elevations in event risk (hazard ratio: 2.46 to 6.09; p < 0.0001). The ROC curve for prediction of death or MI was 0.7052 for CAD-RADS, which was noninferior to the Duke Index (0.7073; p = 0.893) and traditional CAD classification (0.7095; p = 0.783). ICA rates were 13% for CAD-RADS 0 to 2, 66% for CAD-RADS 3, and 84% for CAD-RADS ≥4A. For CAD-RADS 3, 58% of all catheterizations occurred within the first 30 days of follow-up. In a patient subset with available medication data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Fluorescence resonance energy transfer in microemulsions composed of tripled-chain surface active ionic liquids, RTILs, and biological solvent: an excitation wavelength dependence study.

    PubMed

    Banerjee, Chiranjib; Kundu, Niloy; Ghosh, Surajit; Mandal, Sarthak; Kuchlyan, Jagannath; Sarkar, Nilmoni

    2013-08-15

    In this article we have reported the fluorescence resonance energy transfer (FRET) study in our earlier characterized surface active ionic liquids (SAILs)-containing microemulsion, i.e., N-methyl-N-propylpyrrolidinium bis(trifluoromethanesulfonyl)imide ([P13][Tf2N])/[CTA][AOT]/isopropyl myristate ([IPM]) and N,N,N-trimethyl-N-propylammonium bis(trifluoromethanesulfonyl)imide ([N3111][Tf2N])/[CTA][AOT]/[IPM] microemulsions (Banerjee, C.; Mandal, S.; Ghosh, S.; Kuchlyan, J.; Kundu, N.; Sarkar, N. J. Phys. Chem. B 2013, 117, 3927-3934). The occurrence of effective FRET from the donor, coumarin-153 (C-153) to the acceptor rhodamine 6G (R6G) is evident from the decrease in the steady state fluorescence intensity of the donor with addition of acceptor and subsequent increase in the fluorescence intensity of the acceptor in the presence of donor. The excitation wavelength dependent FRET from C-153 to R6G has also been performed to assess the dynamic heterogeneity of these confined systems. In time-resolved experiments, the significant rise time of the acceptor in the presence of the donor further confirms the occurrence of FRET. The multiple donor-acceptor (D-A) distances, for various microemulsions, obtained from the rise times of the acceptor emission in the presence of a donor can be rationalized from the varying distribution of the donor, C-153, in the different regions of the microemulsion. Time-resolved measurement reveals that with increasing excitation wavelength from 408 to 440 nm, the contribution of the faster rise component of FRET increases significantly due to the close proximity of the C-153 and R6G in the polar region of the microemulsion where occurrence of FRET is very high. Moreover, we have also studied the FRET with variation of R (R = [room temperature ionic liquids (RTILs)]/[surfactant]) and shown that the effect of excitation wavelength on FRET is similar irrespective of R values.

  6. The Role of Duplex Ultrasound In Detecting Graft Thrombosis And Endoleak After Endovascular Aortic Repair For Abdominal Aneurysm.

    PubMed

    Mazzaccaro, Daniela; Farina, Augusto; Petsos, Kostantinos; Nano, Giovanni

    2018-05-19

    to assess the role of DUS in detecting endoleaks (EL) and graft thrombosis (GT) in a cohort of patients submitted to EVAR for elective infrarenal AAA in two centers. Data of all consecutive patients treated in two Operative Unit of Vascular Surgery, from 01/01/2000 to 31/12/2016, were retrospectively collected and evaluated. Follow-up data were analyzed to evaluate survival and device-related complications, both at thirty-day and in the mid-term. The results of CTA and DUS that were performed yearly, with a time interval between the two exams lower than 30 days, were paired in terms of maximum transverse diameters of the aneurysmal sac, identification of EL and of GT. Sensibility (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV) and accuracy (ACC) of the DUS were calculated with respect to data of each paired CTA and to data of the real clinical diagnosis of either EL or GT. A Student's t test was performed to compare the aneurysmal sac diameters measured with DUS to those of CTA. "Kappa" coefficient of agreement was also calculated. A P value <0.05 was the level reference for statistical significance. A total of 920 patients (104 female, 11.3%) underwent EVAR for elective infrarenal AAA. Technical success was achieved in 910 cases (98.9%). At 30 days, there were 5 deaths (0.5%), no GT and 3 small type II EL which didn't require any adjunctive procedure. Mean follow-up was 64.8 months (range 1-120.3 months). Survival and freedom from complications were estimated to be 78.4%+1.9% and 48.3%+1.7% respectively at 10 years. Seventy-six more EL and 8 GT were recorded. Considering the CTA as the gold standard, SE, SP, and ACC of DUS in the detection of the EL were 93.2%+5.8%, 98.8%+1.1% and 97.8%, respectively, with a PPV of 94.5%+5.2% and a NPV of 98.3%+1.4%. Considering however the real diagnosis of the EL, SE, SP and ACC of DUS were slightly lower (89.4%+6.9%, 98.5%+1.3% and 96.9%, respectively), as well as PPV and NPV (93.1%+5.8% and 97.7%+1.6% respectively). K coefficient of agreement between the measurements of the sac maximum transverse diameter recorded at DUS and CTA was 0.91, with a little underestimation of the aneurysm diameter at DUS if compared to CTA (mean diameter difference of 2.5 mm, 95% CI: 2.25-2.75mm). DUS has proven to be a reliable exam in identifying all GT and most EL after EVAR, if compared to CTA. A good correlation was also observed between the measurements of the sac maximum transverse diameter recorded at DUS and CTA, with a little underestimation of the aneurysm diameter at DUS if compared to CTA. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. 77 FR 38229 - Rules Prohibiting the Aggregation of Orders To Satisfy Minimum Block Sizes or Cap Size...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ..., investment advisers and foreign persons (as described in this release), to transact block trades for customers who are not ECPs, if such CTA, investment adviser or foreign person has more than $25,000,000 in... eligible contract participants (``non-ECPS''), if such CTA, investment adviser or foreign person has more...

  8. Locality-Aware CTA Clustering For Modern GPUs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ang; Song, Shuaiwen; Liu, Weifeng

    2017-04-08

    In this paper, we proposed a novel clustering technique for tapping into the performance potential of a largely ignored type of locality: inter-CTA locality. We first demonstrated the capability of the existing GPU hardware to exploit such locality, both spatially and temporally, on L1 or L1/Tex unified cache. To verify the potential of this locality, we quantified its existence in a broad spectrum of applications and discussed its sources of origin. Based on these insights, we proposed the concept of CTA-Clustering and its associated software techniques. Finally, We evaluated these techniques on all modern generations of NVIDIA GPU architectures. Themore » experimental results showed that our proposed clustering techniques could significantly improve on-chip cache performance.« less

  9. Learning to Predict Consequences as a Method of Knowledge Transfer in Reinforcement Learning.

    PubMed

    Chalmers, Eric; Contreras, Edgar Bermudez; Robertson, Brandon; Luczak, Artur; Gruber, Aaron

    2017-04-17

    The reinforcement learning (RL) paradigm allows agents to solve tasks through trial-and-error learning. To be capable of efficient, long-term learning, RL agents should be able to apply knowledge gained in the past to new tasks they may encounter in the future. The ability to predict actions' consequences may facilitate such knowledge transfer. We consider here domains where an RL agent has access to two kinds of information: agent-centric information with constant semantics across tasks, and environment-centric information, which is necessary to solve the task, but with semantics that differ between tasks. For example, in robot navigation, environment-centric information may include the robot's geographic location, while agent-centric information may include sensor readings of various nearby obstacles. We propose that these situations provide an opportunity for a very natural style of knowledge transfer, in which the agent learns to predict actions' environmental consequences using agent-centric information. These predictions contain important information about the affordances and dangers present in a novel environment, and can effectively transfer knowledge from agent-centric to environment-centric learning systems. Using several example problems including spatial navigation and network routing, we show that our knowledge transfer approach can allow faster and lower cost learning than existing alternatives.

  10. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing.

    PubMed

    Nielsen, Lene H; Olsen, Jens; Markenvard, John; Jensen, Jesper M; Nørgaard, Bjarne L

    2013-05-01

    The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). In two coronary units at Lillebaelt Hospital, Denmark, 498 patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs associated with downstream diagnostic utilization (DTU), treatment, ambulatory visits, and hospitalizations were registered. There was no difference between cohorts in demographic characteristics or the pre-test probability of significant CAD. The mean (SD) age was 56 (11) years; 52% were men; and 96% were at low-intermediate pre-test probability of CAD. All serious cardiac events (n = 3) during follow-up occurred in patients with a negative ex-test result. Mean costs per patient associated with DTU, ambulatory visits, and cardiovascular medication were significantly higher in the ex-test than in the CTA group. The mean (SD) total costs per patient at the end of the follow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs when compared with the ex-test. These findings need confirmation in future prospective trials.

  11. Aortitis in giant cell arteritis: diagnosis with FDG PET/CT and agreement with CT angiography.

    PubMed

    Hommada, Mona; Mekinian, Arsène; Brillet, Pierre-Yves; Abad, Sébastien; Larroche, Claire; Dhôte, Robin; Fain, Olivier; Soussan, Michael

    2017-11-01

    To assess the detection rate of aortitis in giant cell arteritis (GCA) with fluorodeoxyglucose positron emission tomography/computed tomography (PET) and to compare the findings with CT angiography (CTA). Fifty-two GCA patients and 27 controls were included. GCA patients had a PET scan at diagnosis (35/52) or during relapse (17/52). Concomitant CTA was performed in 35/52 patients. Aortitis was defined as FDG uptake higher than the liver for PET and wall thickness≥3mm for CTA. Agreement between PET and CTA was evaluated by the kappa coefficient and Spearman correlation coefficient. Aortitis was diagnosed using PET in 40% (14/35) of patients at diagnosis and in 0% of controls (0/27). Agreement was perfect between PET and CT at a patient-based level, and very good at a vascular segment-based level (kappa: 0.72 to 1). PET was positive in 35% (6/17) of patients scanned during GCA relapse, showing aortitis (n=4) and/or articular uptake (n=4). Discrepancies between PET and CT were observed only in relapsing GCA (n=3). Correlation between the maximum standardized uptake value and wall thickness was moderate at diagnosis (r: 0.57 to 0.7) and not statistically significant during relapse. The detection rate of aortitis in GCA patients using PET is 40%, approximately in the range of CTA rates, suggesting that the two techniques have similar sensitivity. PET seems valuable in relapsing GCA, allowing the detection of vascular and articular activities. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. The utility of hand transplantation in hand amputee patients.

    PubMed

    Alolabi, Noor; Chuback, Jennifer; Grad, Sharon; Thoma, Achilles

    2015-01-01

    To measure the desirable health outcome, termed utility, and the expected quality-adjusted life years (QALYs) gained with hand composite tissue allotransplantation (CTA) using hand amputee patients and the general public. Using the standard gamble (SG) and time trade-off (TTO) techniques, utilities were obtained from 30 general public participants and 12 amputee patients. The health utility and net QALYs gained or lost with transplantation were computed. A sensitivity analysis was conducted to account for the effects of lifelong immunosuppression on the life expectancy of transplant recipients. Higher scores represent greater utility. Hand amputation mean health utility as measured by the SG and TTO methods, respectively, was 0.72 and 0.80 for the general public and 0.69 and 0.70 for hand amputees. In comparison, hand CTA mean health utility was 0.74 and 0.82 for the general public and 0.83 and 0.86 for amputees. Hand CTA imparted an expected gain of 0.9 QALYs (SG and TTO) in the general public and 7.0 (TTO) and 7.8 (SG) QALYs in hand amputees. A loss of at least 1.7 QALYs was demonstrated when decreasing the life expectancy in the sensitivity analysis in the hand amputee group. Hand amputee patients did not show a preference toward hand CTA with its inherent risks. With this procedure being increasingly adopted worldwide, the benefits must be carefully weighed against the risks of lifelong immunosuppressive therapy. This study does not show clear benefit to advocate hand CTA. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Cognitive Task Analysis: Bringing Olympic Athlete Style Training to Surgical Education.

    PubMed

    Wingfield, Laura R; Kulendran, Myutan; Chow, Andre; Nehme, Jean; Purkayastha, Sanjay

    2015-08-01

    Surgical training is changing and evolving as time, pressure, and legislative demands continue to mount on trainee surgeons. A paradigm change in the focus of training has resulted in experts examining the cognitive steps needed to perform complex and often highly pressurized surgical procedures. To provide an overview of the collective evidence on cognitive task analysis (CTA) as a surgical training method, and determine if CTA improves a surgeon's performance as measured by technical and nontechnical skills assessment, including precision, accuracy, and operative errors. A systematic literature review was performed. PubMed, Cochrane, and reference lists were analyzed for appropriate inclusion. A total of 595 surgical participants were identified through the literature review and a total of 13 articles were included. Of these articles, 6 studies focused on general surgery, 2 focused on practical procedures relevant to surgery (central venous catheterization placement), 2 studies focused on head and neck surgical procedures (cricothyroidotomy and percutaneous tracheostomy placement), 2 studies highlighted vascular procedures (endovascular aortic aneurysm repair and carotid artery stenting), and 1 detailed endovascular repair (abdominal aorta and thoracic aorta). Overall, 92.3% of studies showed that CTA improves surgical outcome parameters, including time, precision, accuracy, and error reduction in both simulated and real-world environments. CTA has been shown to be a more effective training tool when compared with traditional methods of surgical training. There is a need for the introduction of CTA into surgical curriculums as this can improve surgical skill and ultimately create better patient outcomes. © The Author(s) 2014.

  14. Electrocardiogram‐gated coronary CT angiography dose estimates using ImPACT

    PubMed Central

    Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Koshida, Kichiro; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Toyama, Hiroshi; Kato, Ryoichi

    2016-01-01

    The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), prospective CTA, continuous CTA/cardiac function analysis (CFA), and CTA/CFA modulation. Accordingly, we clarified the CT dose index (CTDI) to determine the relationship between heart rate (HR) and X‐ray exposure. As a secondary objective, we compared radiation doses using modified ImPACT, a whole‐body dosimetry phantom study, and the k‐factor method to verify the validity of the dose results obtained with modified ImPACT. The effective dose determined for the reference person (4.66 mSv at 60 beats per minute (bpm) and 33.43 mSv at 90 bpm) were approximately 10% less than those determined for the phantom study (5.28 mSv and 36.68 mSv). The effective doses according to the k‐factor (0.014 mSv·mGy−1·cm−1; 2.57 mSv and 17.10 mSv) were significantly lower than those obtained with the other two methods. In the present study, we have shown that ImPACT, when modified for cardiac applications, can assess both absorbed and effective doses. The results of our dose comparison indicate that modified ImPACT dose assessment is a promising and practical method for evaluating coronary CTA. PACS number(s): 87.57.Q‐, 87.59.Dj, 87.57.uq PMID:27455500

  15. Computed Tomography Perfusion Improves Diagnostic Accuracy in Acute Posterior Circulation Stroke.

    PubMed

    Sporns, Peter; Schmidt, Rene; Minnerup, Jens; Dziewas, Rainer; Kemmling, André; Dittrich, Ralf; Zoubi, Tarek; Heermann, Philipp; Cnyrim, Christian; Schwindt, Wolfram; Heindel, Walter; Niederstadt, Thomas; Hanning, Uta

    2016-01-01

    Computed tomography perfusion (CTP) has a high diagnostic value in the detection of acute ischemic stroke in the anterior circulation. However, the diagnostic value in suspected posterior circulation (PC) stroke is uncertain, and whole brain volume perfusion is not yet in widespread use. We therefore studied the additional value of whole brain volume perfusion to non-contrast CT (NCCT) and CT angiography source images (CTA-SI) for infarct detection in patients with suspected acute ischemic PC stroke. This is a retrospective review of patients with suspected stroke in the PC in a database of our stroke center (n = 3,011) who underwent NCCT, CTA and CTP within 9 h after stroke onset and CT or MRI on follow-up. Images were evaluated for signs and pc-ASPECTS locations of ischemia. Three imaging models - A (NCCT), B (NCCT + CTA-SI) and C (NCCT + CTA-SI + CTP) - were compared with regard to the misclassification rate relative to gold standard (infarction in follow-up imaging) using the McNemar's test. Of 3,011 stroke patients, 267 patients had a suspected stroke in the PC and 188 patients (70.4%) evidenced a PC infarct on follow-up imaging. The sensitivity of Model C (76.6%) was higher compared with that of Model A (21.3%) and Model B (43.6%). CTP detected significantly more ischemic lesions, especially in the cerebellum, posterior cerebral artery territory and thalami. Our findings in a large cohort of consecutive patients show that CTP detects significantly more ischemic strokes in the PC than CTA and NCCT alone. © 2016 S. Karger AG, Basel.

  16. Accuracy of magnetic resonance imaging, magnetic resonance arthrography and computed tomography for the detection of chondral lesions of the knee.

    PubMed

    Smith, Toby O; Drew, Benjamin T; Toms, Andoni P; Donell, Simon T; Hing, Caroline B

    2012-12-01

    To assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and computed tomography arthrography (CTA) for the detection of chondral lesions of the patellofemoral and tibiofemoral joints. A review of published and unpublished literature sources was conducted on 22nd September 2011. All studies assessing the diagnostic test accuracy (sensitivity/specificity) of MRI or MRA or CTA for the assessment of adults with chondral (cartilage) lesions of the knee (tibiofemoral/patellofemoral joints) with surgical comparison (arthroscopic or open) as the reference test were included. Data were analysed through meta-analysis. Twenty-seven studies assessing 2,592 knees from 2,509 patients were included. The findings indicated that whilst presenting a high specificity (0.95-0.99), the sensitivity of MRA, MRI and CTA ranged from 0.70 to 0.80. MRA was superior to MRI and CTA for the detection of patellofemoral joint chondral lesions and that higher field-strength MRI scanner and grade four lesions were more accurately detected compared with lower field-strength and grade one lesions. There appeared no substantial difference in diagnostic accuracy between the interpretation from musculoskeletal and general radiologists when undertaking an MRI review of tibiofemoral and patellofemoral chondral lesions. Specialist radiological imaging is specific for cartilage disease in the knee but has poorer sensitivity to determine the therapeutic options in this population. Due to this limitation, there remains little indication to replace the 'gold-standard' arthroscopic investigation with MRI, MRA or CTA for the assessment of adults with chondral lesions of the knee. II.

  17. The control, monitor, and alarm system for the ICT equipment of the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, Fulvio; Fioretti, Valentina; Tanci, Claudio; Conforti, Vito; Tacchini, Alessandro; Leto, Giuseppe; Gallozzi, Stefano; Bulgarelli, Andrea; Trifoglio, Massimo; Malaguti, Giuseppe; Zoli, Andrea

    2014-07-01

    ASTRI is an Italian flagship project whose first goal is the realization of an end-to-end telescope prototype, named ASTRI SST-2M, for the Cherenkov Telescope Array (CTA). The prototype will be installed in Italy during Fall 2014. A second goal will be the realization of the ASTRI/CTA mini-array which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The Information and Communication Technology (ICT) equipment necessary to drive the infrastructure for the ASTRI SST-2M prototype is being designed as a complete and stand-alone computer center. The design goal is to obtain basic ICT equipment that might be scaled, with a low level of redundancy, for the ASTRI/CTA mini-array, taking into account the necessary control, monitor and alarm system requirements. The ICT equipment envisaged at the Serra La Nave observing station in Italy, where the ASTRI SST-2M telescope prototype will operate, includes computers, servers and workstations, network devices, an uninterruptable power supply system, and air conditioning systems. Suitable hardware and software tools will allow the parameters related to the behavior and health of each item of equipment to be controlled and monitored. This paper presents the proposed architecture and technical solutions that integrate the ICT equipment in the framework of the Observatory Control System package of the ASTRI/CTA Mini- Array Software System, MASS, to allow their local and remote control and monitoring. An end-toend test case using an Internet Protocol thermometer is reported in detail.

  18. Phantom-based standardization of CT angiography images for spot sign detection.

    PubMed

    Morotti, Andrea; Romero, Javier M; Jessel, Michael J; Hernandez, Andrew M; Vashkevich, Anastasia; Schwab, Kristin; Burns, Joseph D; Shah, Qaisar A; Bergman, Thomas A; Suri, M Fareed K; Ezzeddine, Mustapha; Kirmani, Jawad F; Agarwal, Sachin; Shapshak, Angela Hays; Messe, Steven R; Venkatasubramanian, Chitra; Palmieri, Katherine; Lewandowski, Christopher; Chang, Tiffany R; Chang, Ira; Rose, David Z; Smith, Wade; Hsu, Chung Y; Liu, Chun-Lin; Lien, Li-Ming; Hsiao, Chen-Yu; Iwama, Toru; Afzal, Mohammad Rauf; Cassarly, Christy; Greenberg, Steven M; Martin, Renee' Hebert; Qureshi, Adnan I; Rosand, Jonathan; Boone, John M; Goldstein, Joshua N

    2017-09-01

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p < 0.001). All spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion.

  19. Evidence for shock-shock interaction in the jet of CTA 102

    NASA Astrophysics Data System (ADS)

    Fromm, C. M.; Perucho, M.; Savolainen, T.; Ros, E.; Lobanov, A. P.; Zensus, J. A.; Lähteenmäki, A.

    2011-02-01

    We have found evidence for interaction between a standing and a traveling shock in the jet of the blazar CTA 102. Our result is based in the study of the spectral evolution of the turnover frequency-turnover flux density (νm, Sm) plane. The radio/mm light curves were taken during a major radio outburst in April 2006.

  20. How Curriculum and Classroom Achievement Predict Teacher Time on Lecture- and Inquiry-Based Mathematics Activities

    ERIC Educational Resources Information Center

    Kaufman, Julia H.; Rita Karam; Pane, John F.; Junker, Brian W.

    2012-01-01

    This study drew on data from a large, randomized trial of Cognitive Tutor Algebra (CTA) in high-poverty settings to investigate how mathematics curricula and classroom achievement related to teacher reports of time spent on inquiry-based and lecture-based mathematics activities. We found that teachers using the CTA curriculum reported more time on…

  1. Memory Trace Reactivation and Behavioral Response during Retrieval Are Differentially Modulated by Amygdalar Glutamate Receptors Activity: Interaction between Amygdala and Insular Cortex

    ERIC Educational Resources Information Center

    Osorio-Gómez, Daniel; Guzmán-Ramos, Kioko; Bermúdez-Rattoni, Federico

    2017-01-01

    The insular cortex (IC) is required for conditioned taste aversion (CTA) retrieval. However, it remains unknown which cortical neurotransmitters levels are modified upon CTA retrieval. Using in vivo microdialysis, we observed that there were clear elevations in extracellular glutamate, norepinephrine, and dopamine in and around the center of the…

  2. 78 FR 21648 - Consolidated Tape Association; Notice of Filing and Immediate Effectiveness of the Seventeenth...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-11

    ... subscribers pay for Network B last sale information under the CTA Plan and for Network B quotation information under the CQ Plan into one monthly fee of $24.00 per device for both last sale information and quotation... both Plans was in 1995. The CTA Plan, pursuant to which markets collect and disseminate last sale price...

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavagna, Enrico; D'Andrea, Paolo; Schiavon, Francesco

    Purpose: To evaluate failing hemodialysis arteriovenous fistulas with helical CT angiography (CTA), MR angiography (MRA), and digital subtraction angiography (DSA), and to compare the efficacy of the three techniques in detecting the number, location, grade, and extent of stenoses and in assessing the technical results of percutaneous transluminal angioplasty (PTA) and stenting.Methods: Thirteen patients with Brescia-Cimino arteriovenous fistula malfunction underwent MRA and CTA of the fistula and, within 1 week, DSA. A total of 11 PTAs were performed; in three cases an MR-compatible stent was placed. DSA served as the gold standard for comparison in all patients. The presence, site,more » and number of stenoses or occlusions and the technical results of percutaneous procedures were assessed with DSA, CTA, and MRA.Results: MRA underestimated a single stenosis in one patient; CTA and MRA did not overestimate any stenosis. Significant artifacts related to stent geometry and/or underlying metal were seen in MRA sequences in two cases.Conclusions: CT and MRI can provide information regarding the degree of vascular impairment, helping to stratify patients into those who can have PTA (single or multiple stenoses) versus those who require an operative procedure (occlusion). Conventional angiography can be reserved for candidates for percutaneous intervention.« less

  4. The gamma-ray Cherenkov telescope for the Cherenkov telescope array

    NASA Astrophysics Data System (ADS)

    Tibaldo, L.; Abchiche, A.; Allan, D.; Amans, J.-P.; Armstrong, T. P.; Balzer, A.; Berge, D.; Boisson, C.; Bousquet, J.-J.; Brown, A. M.; Bryan, M.; Buchholtz, G.; Chadwick, P. M.; Costantini, H.; Cotter, G.; Daniel, M. K.; De Franco, A.; De Frondat, F.; Dournaux, J.-L.; Dumas, D.; Ernenwein, J.-P.; Fasola, G.; Funk, S.; Gironnet, J.; Graham, J. A.; Greenshaw, T.; Hervet, O.; Hidaka, N.; Hinton, J. A.; Huet, J.-M.; Jankowsky, D.; Jegouzo, I.; Jogler, T.; Kraus, M.; Lapington, J. S.; Laporte, P.; Lefaucheur, J.; Markoff, S.; Melse, T.; Mohrmann, L.; Molyneux, P.; Nolan, S. J.; Okumura, A.; Osborne, J. P.; Parsons, R. D.; Rosen, S.; Ross, D.; Rowell, G.; Rulten, C. B.; Sato, Y.; Sayède, F.; Schmoll, J.; Schoorlemmer, H.; Servillat, M.; Sol, H.; Stamatescu, V.; Stephan, M.; Stuik, R.; Sykes, J.; Tajima, H.; Thornhill, J.; Trichard, C.; Vink, J.; Watson, J. J.; White, R.; Yamane, N.; Zech, A.; Zink, A.; Zorn, J.; CTA Consortium

    2017-01-01

    The Cherenkov Telescope Array (CTA) is a forthcoming ground-based observatory for very-high-energy gamma rays. CTA will consist of two arrays of imaging atmospheric Cherenkov telescopes in the Northern and Southern hemispheres, and will combine telescopes of different types to achieve unprecedented performance and energy coverage. The Gamma-ray Cherenkov Telescope (GCT) is one of the small-sized telescopes proposed for CTA to explore the energy range from a few TeV to hundreds of TeV with a field of view ≳ 8° and angular resolution of a few arcminutes. The GCT design features dual-mirror Schwarzschild-Couder optics and a compact camera based on densely-pixelated photodetectors as well as custom electronics. In this contribution we provide an overview of the GCT project with focus on prototype development and testing that is currently ongoing. We present results obtained during the first on-telescope campaign in late 2015 at the Observatoire de Paris-Meudon, during which we recorded the first Cherenkov images from atmospheric showers with the GCT multi-anode photomultiplier camera prototype. We also discuss the development of a second GCT camera prototype with silicon photomultipliers as photosensors, and plans toward a contribution to the realisation of CTA.

  5. Design of amphoteric chitosan flocculants for phosphate and turbidity removal in wastewater.

    PubMed

    Agbovi, Henry K; Wilson, Lee D

    2018-06-01

    An amphoteric flocculant (CMC-CTA) was synthesized by grafting 3-chloro-2-hydroxypropyl trimethylammonium chloride onto carboxymethyl chitosan (CMC). The turbidity and orthophosphate (P i ) removal properties of chitosan (CHI), CMC, and CMC-CTA were compared in the presence (and absence) of FeCl 3 coagulant. At a fixed FeCl 3 dosage, the effects of flocculant dosage, pH and settling time were evaluated. Turbidity removal (%) and optimal dosage (FeCl 3 ; mg/L) was determined: CMC-CTA (95.8%;5), CHI (88.8%;7.0) and CMC (68.8%;9.0). The corresponding P i removal (%) and dosage (mg/L) are listed: (93.4%;10), (90.6%;10), and (67.4%;5). Optimal turbidity and P i removal occurred at pH 4, where CMC-CTA had greater efficiency over CMC and CHI. The turbidity removal kinetics was described by the pseudo-second-order model, while P i removal followed the pseudo-first-order model. The removal process involves cooperative Coulombic interactions between the biopolymer/Fe(III)/P i and/or kaolinite colloids, along with polymer bridging effects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    PubMed

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  7. Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT

    NASA Astrophysics Data System (ADS)

    Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi

    2017-05-01

    Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.

  8. Small-angle neutron scattering study of the short-range organization of dispersed CsNi[Cr(CN){sub 6}] nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ridier, Karl; Gillon, Béatrice; André, Gilles

    2015-09-21

    Prussian blue analogues magnetic nanoparticles (of radius R{sub 0} = 2.4–8.6 nm) embedded in PVP (polyvinylpyrrolidone) or CTA{sup +} (cetyltrimethylammonium) matrices have been studied using neutron diffraction and small angle neutron scattering (SANS) at several concentrations. For the most diluted particles in neutral PVP, the SANS signal is fully accounted for by a “single-particle” spherical form factor with no structural correlations between the nanoparticles and with radii comparable to those inferred from neutron diffraction. For higher concentration in PVP, structural correlations modify the SANS signal with the appearance of a structure factor peak, which is described using an effective “mean-field” model. A newmore » length scale R{sup * }≈ 3R{sub 0}, corresponding to an effective repulsive interaction radius, is evidenced in PVP samples. In CTA{sup +}, electrostatic interactions play a crucial role and lead to a dense layer of CTA{sup +} around the nanoparticles, which considerably alter the SANS patterns as compared to PVP. The SANS data of nanoparticles in CTA{sup +} are best described by a core-shell model without visible inter-particle structure factor.« less

  9. 7 CFR 331.16 - Transfers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... or CDC prior to the transfer. 7 7 The requirements of this section do not apply to transfers within a... authorization for a transfer, APHIS/CDC Form 2 must be submitted. (e) After authorization is provided by APHIS or CDC, the packaging of the select agent(s) and toxin(s) is performed by an individual approved by...

  10. 7 CFR 331.16 - Transfers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... or CDC prior to the transfer. 7 7 The requirements of this section do not apply to transfers within a... authorization for a transfer, APHIS/CDC Form 2 must be submitted. (e) After authorization is provided by APHIS or CDC, the packaging of the select agent(s) and toxin(s) is performed by an individual approved by...

  11. Performance verification of the FlashCam prototype camera for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Werner, F.; Bauer, C.; Bernhard, S.; Capasso, M.; Diebold, S.; Eisenkolb, F.; Eschbach, S.; Florin, D.; Föhr, C.; Funk, S.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Lahmann, R.; Marszalek, A.; Pfeifer, M.; Principe, G.; Pühlhofer, G.; Pürckhauer, S.; Rajda, P. J.; Reimer, O.; Santangelo, A.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Wolf, D.; Zietara, K.; CTA Consortium

    2017-12-01

    The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is planned to significantly improve upon the sensitivity and precision of the current generation of Cherenkov telescopes. The observatory will consist of several dozens of telescopes with different sizes and equipped with different types of cameras. Of these, the FlashCam camera system is the first to implement a fully digital signal processing chain which allows for a traceable, configurable trigger scheme and flexible signal reconstruction. As of autumn 2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears completion. First results of the ongoing system tests demonstrate that the signal chain and the readout system surpass CTA requirements. The stability of the system is shown using long-term temperature cycling.

  12. Preliminary morphological and X-ray diffraction studies of the crystals of the DNA cetyltrimethylammonium salt.

    PubMed

    Osica, V D; Pyatigorskaya, T L; Polyvtsev, O F; Dembo, A T; Kliya, M O; Vasilchenko, V N; Verkin, B I; Sukharevskya, B Y

    1977-04-01

    Double-stranded DNA molecules (molecular weight 2.5 X 10(5) - 5 X 10(5) daltons) have been crystallized from water-salt solutions as cetyltrimethylammonium salts (CTA-DNA). Variation of crystallization conditions results in a production of different types of CTA-DNA crystals: spherulits, dendrites, needle-shaped and faceted rhombic crystals, the latter beeing up to 0.3 mm on a side. X-ray diffraction data indicate that DNA molecules in the crystals form a hexagonal lattice which parameters vary slightly with the morphological type of the crystal. Comparison of the melting curves of the DNA preparation before and after crystallization suggests that DNA molecules are partially fractionated in the course of crystallization. Crystals of the CTA-DNA-proflavine complex have also been obtained.

  13. Preliminary morphological and X-ray diffraction studies of the crystals of the DNA cetyltrimethylammonium salt.

    PubMed Central

    Osica, V D; Pyatigorskaya, T L; Polyvtsev, O F; Dembo, A T; Kliya, M O; Vasilchenko, V N; Verkin, B I; Sukharevskya, B Y

    1977-01-01

    Double-stranded DNA molecules (molecular weight 2.5 X 10(5) - 5 X 10(5) daltons) have been crystallized from water-salt solutions as cetyltrimethylammonium salts (CTA-DNA). Variation of crystallization conditions results in a production of different types of CTA-DNA crystals: spherulits, dendrites, needle-shaped and faceted rhombic crystals, the latter beeing up to 0.3 mm on a side. X-ray diffraction data indicate that DNA molecules in the crystals form a hexagonal lattice which parameters vary slightly with the morphological type of the crystal. Comparison of the melting curves of the DNA preparation before and after crystallization suggests that DNA molecules are partially fractionated in the course of crystallization. Crystals of the CTA-DNA-proflavine complex have also been obtained. Images PMID:866188

  14. [Spiral CT angiography in practice].

    PubMed

    Pavcec, Zlatko; Zokalj, Ivan; Rumboldt, Zoran; Pal, Andrej; Saghir, Hussein; Ozretić, David; Latin, Branko; Perhoć, Zeljka; Marotti, Miljenko

    2005-01-01

    Incidence of vascular diseases and development of new radiologic techniques in the last three decades has given strong impuls for introduction of non-invasive vascular diagnostic methods. Thanks to the introduction of Doppler ultrasound, new types of computed tomography (CT) and magnetic resonance (MR) scanners, non-invasive vascular diagnostic methods are replacing conventional invasive (catheter) angiographic methods. Computed tomographic angiography (CTA) is a noninvasive vascular diagnostic method based on continuous scanning with CT scanner during intravenous application of contrast material. Performing of CTA is possible after introduction of spiral CT technique whose characteristics are short imaging time and volumetric data acquisition. The main goal of this article, based on our experiences, is to review the role of CTA, performed on single-slice CT scanner, in managment of patients with vascular pathology.

  15. Method of encapsulating polyaminopolycarboxylic acid chelating agents in liposomes

    DOEpatents

    Rahman, Yueh Erh

    1977-11-10

    A method is provided for transferring a polyaminopolycarboxylic acid chelating agent across a cellular membrane by encapsulating the charged chelating agent within liposomes, which liposomes will be taken up by the cells, thereby transferring the chelating agent across the cellular membrane. The chelating agent is encapsulated within liposomes by drying a lipid mixture to form a thin film and wetting the lipid film with a solution containing the chelating agent. Mixing then results in the formation of a suspension of liposomes encapsulating the chelating agent, which liposomes can then be separated.

  16. 78 FR 70380 - Self-Regulatory Organizations; NYSE MKT LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-25

    ... Revising Rule 61(a)(iii)--Equities To Harmonize the Existing Rule Text With the Recent Amendment to the CTA... the existing rule text with the recent amendment to the CTA Plan (and concordant change to the Nasdaq... text of the proposed rule change is available on the Exchange's Web site at www.nyse.com , at the...

  17. Prevention of Posttraumatic Contractures with Ketotifen (PERK)

    DTIC Science & Technology

    2016-10-01

    the Peer Reviewed Orthopaedic Research Program (PRORP) Clinical Trial Award (CTA), W81XWH-16-PRORP-CTA, was submitted. Database development and Pre...and Safety Months Identify database and partner – Clinical Research Unit 1-2 Completed Develop Case Report Forms, consent forms 6-12 Case...report forms completed, consent forms pending – 80% completed Develop database and multicenter submission process 12-18 In progress, 30% completed

  18. The diagnostic performance of CT-derived fractional flow reserve for evaluation of myocardial ischaemia confirmed by invasive fractional flow reserve: a meta-analysis.

    PubMed

    Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J

    2015-05-01

    To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Facteurs influençant l'initiation au traitement antirétroviral des personnes vivant avec le VIH dans les Centres de Traitement Agréés de Bamenda et de Bertoua au Cameroun

    PubMed Central

    Mbopi-Keou, Francois-Xavier; Voundi, Esther Voundi; Kalla, Ginette Claude Mireille; Emah, Irène; Angwafo, Fru; Muna, Walinjom

    2014-01-01

    Introduction L'objectif de ce travail était de déterminer les facteurs influençant l'initiation au traitement antirétroviral des personnes vivant avec le VIH (PVVIH) dans les centres de traitements agrées (CTA) de Bamenda et de Bertoua au Cameroun. Méthodes Il s'agissait d'une étude transversale, analytique réalisée de Janvier à Avril 2011, dans les CTA de Bamenda et de Bertoua. Pour cette étude, nous avons obtenu une clairance éthique. Résultats Nous avons étudiés 460 dossiers de patients séropositifs en phase d'initiation au traitement antirétroviral dans les CTA de Bamenda et de Bertoua, 53,9% et 46,1% respectivement. L ‘âge médian était de 36 ans. La plupart des séropositifs à Bertoua (41) avaient fait un dépistage volontaire du VIH par rapport à ceux de Bamenda (22) (p= 0.008). Il y ‘avait plus de VIH de type 1 et 2 dans le CTA de Bamenda (15) par rapport à Bertoua (3) (p= 0.011). La majorité des patients était classé au stade clinique II à Bamenda (54,0%) tandis qu ‘à Bertoua le stade clinique III était prédominant (52,4%) (p = 0,000). Le taux médian de CD4 était de 133 cellules/mm3 dans le CTA de Bamenda et de 175 cellules/mm3 à Bertoua (p = 0,008). La Zidovudine était plus prescrit à Bamenda et le Ténofovir à Bertoua (p = 0,000). L ‘Efavirenz était plus prescrit à Bertoua tandis que la Névirapine l ‘était plus à Bamenda (p = 0,000). Le Lopinavir/r était plus prescrit à Bamenda qu ‘à Bertoua (p = 0,017). Conclusion Il apparait urgent de standardiser la prise en charge des PVVIH dans les CTA du Cameroun. PMID:25184023

  20. Use of computed tomography renal angiography for screening feline renal transplant donors.

    PubMed

    Bouma, Jennifer L; Aronson, Lillian R; Keith, Dennis G; Saunders, H Mark

    2003-01-01

    Preoperative knowledge of the renal vascular anatomy is important for selection of the appropriate feline renal donor. Intravenous urograms (IVUs) have been performed routinely to screen potential donors at the Veterinary Hospital of the University of Pennsylvania (VHUP), but the vascular phase views lack sufficient detail of the renal vascular anatomy. Computed tomography angiography (CTA), which requires a helical computed tomography (CT) scanner, has been found to provide superior renal vascular anatomic information of prospective human renal donors. The specific aims of this study were as follows: 1) develop the CTA technique for the feline patient; and 2) obtain preliminary information on feline renal vessel anatomy in potential renal donors. Ten healthy, potential feline renal donors were anesthetized and imaged using a third-generation helical CT scanner. The time delay between i.v. contrast medium injection and image acquisition, and other parameters of slice collimation, slice interval, pitch, exposure settings, and reconstruction algorithms were varied to maximize contrast medium opacification of the renal vascular anatomy. Optimal CTA acquisition parameters were determined to be: 1) 10-sec delay post-i.v. bolus of iodinated contrast medium; 2) two serially acquired (corresponding to arterial and venous phases) helical scans through the renal vasculature; 3) pitch of 2 (4 mm/sec patient translation, 2 mm slice collimation); and 4) 120-kVp, 160-mA, and 1-sec exposure settings. Retrospective reconstructed CTA transverse images obtained at a 2-mm slice width and a 1-mm slice interval in combination with two-dimensional reformatted images and three-dimensional reconstructed images were qualitatively evaluated for vascular anatomy; vascular anatomy was confirmed at surgery. Four cats had single renal arteries and veins bilaterally; four cats had double renal veins. One cat had a small accessory artery supplying the caudal pole of the left kidney. One cat had a left renal artery originating from the aorta at a 90 degrees angle with the cranial mesenteric artery. CTA of the feline renal vascular anatomy is feasible, and reconstruction techniques provide excellent anatomic vascular detail. CTA is now used routinely at VHUP to screen all potential feline renal donors.

  1. Is higher body temperature beneficial in ischemic stroke patients with normal admission CT angiography of the cerebral arteries?

    PubMed

    Kvistad, Christopher Elnan; Khanevski, Andrej; Nacu, Aliona; Thomassen, Lars; Waje-Andreassen, Ulrike; Naess, Halvor

    2014-01-01

    Low body temperature is considered beneficial in ischemic stroke due to neuroprotective mechanisms, yet some studies suggest that higher temperatures may improve clot lysis and outcomes in stroke patients treated with tissue plasminogen activator (tPA). The effect of increased body temperature in stroke patients treated with tPA and with normal computed tomography angiography (CTA) on admission is unknown. We hypothesized a beneficial effect of higher body temperature in the absence of visible clots on CTA, possibly due to enhanced lysis of small, peripheral clots. Patients with ischemic stroke admitted to our Stroke Unit between February 2006 and April 2013 were prospectively registered in a database (Bergen NORSTROKE Registry). Ischemic stroke patients treated with tPA with normal CTA of the cerebral arteries were included. Outcomes were assessed by the modified Rankin Scale (mRS) after 1 week. An excellent outcome was defined as mRS=0, and a favorable outcome as mRS=0-1. A total of 172 patients were included, of which 48 (27.9%) had an admission body temperature ≥37.0°C, and 124 (72.1%) had a body temperature <37.0°C. Body temperature ≥37.0°C was independently associated with excellent outcomes (odds ratio [OR]: 2.8; 95% confidence interval [CI]: 1.24-6.46; P=0.014) and favorable outcomes (OR: 2.8; 95% CI: 1.13-4.98; P=0.015) when adjusted for confounders. We found an association between higher admission body temperature and improved outcome in tPA-treated stroke patients with normal admission CTA of the cerebral arteries. This may suggest a beneficial effect of higher body temperature on clot lysis in the absence of visible clots on CTA.

  2. Characterization of a Cartilage-Like Engineered Biomass Using a Self-Aggregating Suspension Culture Model: Molecular Composition Using FT-IRIS

    PubMed Central

    Kim, Minwook; Kraft, Jeffrey J.; Volk, Andrew C.; Pugarelli, Joan; Pleshko, Nancy; Dodge, George R.

    2011-01-01

    Maintenance of chondrocyte phenotype and robust expression and organization of macromolecular components with suitable cartilaginous properties is an ultimate goal in cartilage tissue engineering. We used a self-aggregating suspension culture (SASC) method to produce an engineered cartilage, “cartilage tissue analog” (CTA). With an objective of understanding the stability of phenotype of the CTA over long periods, we cultured chondrocytes up to 4 years and analyzed the matrix. Both early (eCTAs) (6 months) and aged (aCTAs) (4 years) showed type II collagen throughout with higher concentrations near the edge. Using Fourier transform-infrared imaging spectroscopy (FT-IRIS), proteoglycan/collagen ratio of eCTA was 2.8 times greater than native cartilage at 1 week, but the ratio was balanced to native level (p = 0.017) by 36 weeks. Surprisingly, aCTAs maintained the hyaline characteristics, but there was evidence of calcification within the tissue with a distinct range of intensities. Mineral/matrix ratio of those aCTA with “intensive” calcification was significantly higher (p = 0.017) than the “partial,” but when compared to native bone the ratio of “intensive” aCTAs was 2.4 times lower. In this study we utilized the imaging approach of FT-IRIS and have shown that a biomaterial formed is compositionally closely related to natural cartilage for long periods in culture. We show that this culture platform can maintain a CTA for extended periods of time (4 years) and under those conditions signs of mineralization can be found. This method of cartilage tissue engineering is a promising method to generate cartilaginous biomaterial and may have potential to be utilized in both cartilage and boney repairs. PMID:21630329

  3. Long-term Cost-Effectiveness of Diagnostic Tests for Assessing Stable Chest Pain: Modeled Analysis of Anatomical and Functional Strategies.

    PubMed

    Bertoldi, Eduardo G; Stella, Steffan F; Rohde, Luis E; Polanczyk, Carisi A

    2016-05-01

    Several tests exist for diagnosing coronary artery disease, with varying accuracy and cost. We sought to provide cost-effectiveness information to aid physicians and decision-makers in selecting the most appropriate testing strategy. We used the state-transitions (Markov) model from the Brazilian public health system perspective with a lifetime horizon. Diagnostic strategies were based on exercise electrocardiography (Ex-ECG), stress echocardiography (ECHO), single-photon emission computed tomography (SPECT), computed tomography coronary angiography (CTA), or stress cardiac magnetic resonance imaging (C-MRI) as the initial test. Systematic review provided input data for test accuracy and long-term prognosis. Cost data were derived from the Brazilian public health system. Diagnostic test strategy had a small but measurable impact in quality-adjusted life-years gained. Switching from Ex-ECG to CTA-based strategies improved outcomes at an incremental cost-effectiveness ratio of 3100 international dollars per quality-adjusted life-year. ECHO-based strategies resulted in cost and effectiveness almost identical to CTA, and SPECT-based strategies were dominated because of their much higher cost. Strategies based on stress C-MRI were most effective, but the incremental cost-effectiveness ratio vs CTA was higher than the proposed willingness-to-pay threshold. Invasive strategies were dominant in the high pretest probability setting. Sensitivity analysis showed that results were sensitive to costs of CTA, ECHO, and C-MRI. Coronary CT is cost-effective for the diagnosis of coronary artery disease and should be included in the Brazilian public health system. Stress ECHO has a similar performance and is an acceptable alternative for most patients, but invasive strategies should be reserved for patients at high risk. © 2016 Wiley Periodicals, Inc.

  4. Role of time-resolved-CTA in intracranial arteriovenous malformation evaluation at 128-slice CT in comparison with digital subtraction angiography.

    PubMed

    Singh, Rupinder; Gupta, Vivek; Ahuja, Chirag; Kumar, Ajay; Mukherjee, Kanchan K; Khandelwal, Niranjan

    2018-06-01

    Introduction The present study aimed to evaluate the accuracy of time-resolved-computed tomographic angiography (TR-CTA) on a 128-slice CT scanner vis-à-vis cerebral digital subtraction angiography (DSA) in defining the morphological and haemodynamic characteristics of cerebral arteriovenous malformation (AVM). Methods Twenty-one patients (age range 10-46, mean 24.8 years) with clinical suspicion of AVM and three patients (age range 23-35, mean 24.3 years) with diagnosed AVM who were on follow-up underwent DSA and TR-CTA, on average 1.5 days apart. Three independent neuroradiologists analysed both studies in a blinded fashion based on the following parameters: AVM location, arterial feeder territories, venous drainage pattern, nidus flow characteristics, venous outflow obstruction, arterial feeder enlargement, external carotid artery feeder, location of aneurysm if any, leptomeningeal and transdural recruitment, neoangiogenesis, and pseudophlebitic pattern. Results The TR-CTA correctly demonstrated AVM in all 21 positive cases. It concordantly detected location (21/21), venous drainage pattern (21/21), nidus flow characteristics (21/21), and the venous outflow obstruction (9/9). However, discordance was seen in the demonstration of the arterial feeder (2/45) ( p = 0.49), arterial enlargement (13/17) ( p = 0.103), external carotid artery feeder (0/1), aneurysmal location (3/5) ( p = 0.40), leptomeningeal recruitment (1/3) ( p = 0.40), neoangiogenesis (0/4) ( p = 0.028) and in the pseudophlebitic pattern (2/5) ( p = 0.167) demonstration. Conclusions The results suggest that TR-CTA can provide the important features of cerebral AVM which are required in patient management.

  5. 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

    PubMed

    Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Murai, Yasuo; Orita, Erika; Matsumura, Yoshio; Kumita, Shin-Ichiro

    2016-03-01

    Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.

  6. Screening CT angiography for pediatric blunt cerebrovascular injury with emphasis on the cervical "seatbelt sign".

    PubMed

    Desai, N K; Kang, J; Chokshi, F H

    2014-09-01

    There are no standard screening guidelines to evaluate blunt cerebrovascular injury in children. The purpose of this retrospective study was to understand the clinical and radiologic risk factors associated with pediatric blunt cerebrovascular injury on CTA of the neck with primary attention to the cervical "seatbelt sign." Radiology reports from 2002 to 2012 were queried for the examination "CTA neck." The electronic medical record was reviewed for mechanism of injury, Glasgow Coma Scale score, and physical examination findings. Radiology reports from adjunct radiographic studies were reviewed. CTA neck examinations with reported blunt cerebrovascular injury were reviewed to confirm imaging findings. Patients with penetrating injury or those without a history of trauma were excluded. Four hundred sixty-three patients underwent CTA of the neck; 137 had blunt trauma. Forty-two of 85 patients involved in a motor vehicle collision had a cervical seatbelt sign; none had blunt cerebrovascular injury. Nine vessels (4 vertebral arteries, 4 ICAs, 1 common carotid artery) in 8 patients ultimately were diagnosed with various grades (I-IV) of blunt cerebrovascular injury, representing 5.8% (8/137) of the population screened for blunt neck trauma. The mean Glasgow Coma Scale score was significantly lower (P=.02) in the blunt cerebrovascular injury group versus the non-blunt cerebrovascular injury group. Although not statistically significant, patients with blunt cerebrovascular injury had a higher tendency to have additional traumatic injuries, primarily basilar skull fractures (P=.05) and intracranial hemorrhage (P=.13). A common indication for neck CTA, the cervical seatbelt sign, was not associated with blunt cerebrovascular injury. With the exception of Glasgow Coma Scale score, no single risk factor was statistically significant in predicting vascular injury in this series. © 2014 by American Journal of Neuroradiology.

  7. Stimulation of the dorsal periaqueductal gray enhances spontaneous recovery of a conditioned taste aversion

    PubMed Central

    Mickley, G. Andrew; Ketchesin, Kyle D.; Ramos, Linnet; Luchsinger, Joseph R.; Rogers, Morgan M.; Wiles, Nathanael R.; Hoxha, Nita

    2012-01-01

    Due to its relevance to clinical practice, extinction of learned fears has been a major focus of recent research. However, less is known about the means by which conditioned fears re-emerge (i.e., spontaneously recover) as time passes or contexts change following extinction. The periaqueductal gray represents the final common pathway mediating defensive reactions to fear and we have reported previously that the dorsolateral PAG (dlPAG) exhibits a small but reliable increase in neural activity (as measured by c-fos protein immunoreactivity) when spontaneous recovery (SR) of a conditioned taste aversion (CTA) is reduced. Here we extend these correlational studies to determine if inducing dlPAG c-fos expression through electrical brain stimulation could cause a reduction in SR of a CTA. Male Sprague-Dawley rats acquired a strong aversion to saccharin (conditioned stimulus; CS) and then underwent CTA extinction through multiple non-reinforced exposures to the CS. Following a 30-day latency period after asymptotic extinction was achieved; rats either received stimulation of the dorsal PAG (dPAG) or stimulation of closely adjacent structures. Sixty minutes following the stimulation, rats were again presented with the saccharin solution as we tested for SR of the CTA. The brain stimulation evoked c-fos expression around the tip of the electrodes. However, stimulation of the dPAG failed to reduce SR of the previously extinguished CTA. In fact, dPAG stimulation caused rats to significantly suppress their saccharin drinking (relative to controls) – indicating an enhanced SR. These data refute a cause-and-effect relationship between enhanced dPAG c-fos expression and a reduction in SR. However, they highlight a role for the dPAG in modulating SR of extinguished CTAs. PMID:23183042

  8. Economic Outcomes with Anatomic versus Functional Diagnostic Testing for Coronary Artery Disease

    PubMed Central

    Mark, Daniel B.; Federspiel, Jerome J.; Cowper, Patricia A.; Anstrom, Kevin J.; Hoffmann, Udo; Patel, Manesh R.; Davidson-Ray, Linda; Daniels, Melanie R.; Cooper, Lawton S.; Knight, J. David; Lee, Kerry L.; Douglas, Pamela S.

    2016-01-01

    Background The PROMISE trial found that initial use of ≥64-slice multidetector computed tomographic angiography (CTA) versus functional diagnostic testing strategies did not improve clinical outcomes in stable symptomatic patients with suspected coronary artery disease (CAD) requiring noninvasive testing. Objective Economic analysis of PROMISE, a major secondary aim. Design Prospective economic study from the US perspective. Comparisons were made by intention-to-treat. Confidence intervals were calculated using bootstrap methods. Setting 190 U.S. centers Patients 9649 U.S. patients enrolled in PROMISE. Enrollment began July 2010 and completed September 2013. Median follow-up was 25 months. Measurements Technical costs of the initial (outpatient) testing strategy were estimated from Premier Research Database data. Hospital-based costs were estimated using hospital bills and Medicare cost-to-charge ratios. Physician fees were taken from the Medicare Fee Schedule. Costs were expressed in 2014 US dollars discounted at 3% and estimated out to 3 years using inverse probability weighting methods. Results The mean initial testing costs were: $174 for exercise ECG; $404 for CTA; $501 to $514 for (exercise, pharmacologic) stress echo; $946 to $1132 for (exercise, pharmacologic) stress nuclear. Mean costs at 90 days for the CTA strategy were $2494 versus $2240 for the functional strategy (mean difference $254, 95% CI −$634 to $906). The difference was associated with more revascularizations and catheterizations (4.25 per 100 patients) with CTA use. After 90 days, the mean cost difference between the arms out to 3 years remained small ($373). Limitations Cost weights for test strategies obtained from sources outside PROMISE. Conclusions CTA and functional diagnostic testing strategies in patients with suspected CAD have similar costs through three years of follow-up. PMID:27214597

  9. Leaves of Hippophae rhamnoides prevent taste aversion in gamma-irradiated rats.

    PubMed

    Gupta, Vanita; Bala, Madhu; Prasad, Jagdish; Singh, Surinder; Gupta, Manish

    2011-12-01

    Hippophae rhamnoides (Sea buckthorn), a traditionally known plant for nutritional and therapeutic values, is under active investigation for radioprotective properties. This study investigated effects of aqueous leaf extract from H. rhamnoides on (60)Co-γ-radiation induced changes in behavior, oxidative stress and serotonin levels in jejunum and plasma of rats. Conditioned taste aversion (CTA) was chosen as the assay to record behavioral changes and was assessed in terms of saccharine preference ratio (SPR). Whole body (60)Co-γ-irradiation (2 Gy) induced significant nonrecoverable CTA (25.6 ± 3.6% SPR, t(6) = 3.499, p < .05) and loss in body weight (b.w.). One time treatment with leaf extract before irradiation, countered radiation induced CTA and loss in body weight. The 12 mg/kg b.w. concentration of leaf extract caused complete extinction of CTA [100.3 ± 6.4% SPR, t(6) = 5.879, p < .01] after day 3 and the effect was significantly higher than positive control, Ondansetrone (70.0 ± 8.9% SPR). Treatment with leaf extract before irradiation significantly countered radiation induced (1) decrease in antioxidant protection, (2) increase in levels of corticosterone (CS) in plasma, (3) increase in levels of serotonin in jejunum and plasma. Present investigation demonstrated that H. rhamnoides leaf extract prevented behavioral changes induced at clinical radiation doses. Hippophae leaves are nontoxic and are being consumed as tea and other beverages. CTA in rats is a considered parallel process to nausea and vomiting in human beings. These findings, put together, suggest that dietary supplements from Hippophae leaves could be developed for preventing behavioral changes in subjects exposed to radiation.

  10. Impact of clinical presentation and pretest likelihood on the relation between calcium score and computed tomographic coronary angiography.

    PubMed

    van Werkhoven, Jacob M; de Boer, Stephanie M; Schuijf, Joanne D; Cademartiri, Filippo; Maffei, Erica; Jukema, J Wouter; Boogers, Mark J; Kroft, Lucia J; de Roos, Albert; Bax, Jeroen J

    2010-12-15

    The purpose of the present study was to assess the impact of clinical presentation and pretest likelihood on the relation between coronary calcium score (CCS) and computed tomographic coronary angiography (CTA) to determine the role of CCS as a gatekeeper to CTA in patients presenting with chest pain. In 576 patients with suspected coronary artery disease (CAD), CCS and CTA were performed. CCS was categorized as 0, 1 to 400, and >400. On CT angiogram the presence of significant CAD (≥50% luminal narrowing) was determined. Significant CAD was observed in 14 of 242 patients (5.8%) with CCS 0, in 94 of 260 patients (36.2%) with CCS 1 to 400, and in 60 of 74 patients (81.1%) with CCS >400. In patients with CCS 0, prevalence of significant CAD increased from 3.9% to 4.1% and 14.3% in nonanginal, atypical, and typical chest pain, respectively, and from 3.4% to 3.9% and 27.3% with a low, intermediate, and high pretest likelihood, respectively. In patients with CCS 1 to 400, prevalence of significant CAD increased from 27.4% to 34.7% and 51.7% in nonanginal, atypical, and typical chest pain, respectively, and from 15.4% to 35.6% and 50% in low, intermediate, and high pretest likelihood, respectively. In patients with CCS >400, prevalence of significant CAD on CT angiogram remained high (>72%) regardless of clinical presentation and pretest likelihood. In conclusion, the relation between CCS and CTA is influenced by clinical presentation and pretest likelihood. These factors should be taken into account when using CCS as a gatekeeper for CTA. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. Fractional Flow Reserve and Coronary Computed Tomographic Angiography: A Review and Critical Analysis.

    PubMed

    Hecht, Harvey S; Narula, Jagat; Fearon, William F

    2016-07-08

    Invasive fractional flow reserve (FFR) is now the gold standard for intervention. Noninvasive functional imaging analyses derived from coronary computed tomographic angiography (CTA) offer alternatives for evaluating lesion-specific ischemia. CT-FFR, CT myocardial perfusion imaging, and transluminal attenuation gradient/corrected contrast opacification have been studied using invasive FFR as the gold standard. CT-FFR has demonstrated significant improvement in specificity and positive predictive value compared with CTA alone for predicting FFR of ≤0.80, as well as decreasing the frequency of nonobstructive invasive coronary angiography. High-risk plaque characteristics have also been strongly implicated in abnormal FFR. Myocardial computed tomographic perfusion is an alternative method with promising results; it involves more radiation and contrast. Transluminal attenuation gradient/corrected contrast opacification is more controversial and may be more related to vessel diameter than stenosis. Important considerations remain: (1) improvement of CTA quality to decrease unevaluable studies, (2) is the diagnostic accuracy of CT-FFR sufficient? (3) can CT-FFR guide intervention without invasive FFR confirmation? (4) what are the long-term outcomes of CT-FFR-guided treatment and how do they compare with other functional imaging-guided paradigms? (5) what degree of stenosis on CTA warrants CT-FFR? (6) how should high-risk plaque be incorporated into treatment decisions? (7) how will CT-FFR influence other functional imaging test utilization, and what will be the effect on the practice of cardiology? (8) will a workstation-based CT-FFR be mandatory? Rapid progress to date suggests that CTA-based lesion-specific ischemia will be the gatekeeper to the cardiac catheterization laboratory and will transform the world of intervention. © 2016 American Heart Association, Inc.

  12. Characterization of a cartilage-like engineered biomass using a self-aggregating suspension culture model: molecular composition using FT-IRIS.

    PubMed

    Kim, Minwook; Kraft, Jeffrey J; Volk, Andrew C; Pugarelli, Joan; Pleshko, Nancy; Dodge, George R

    2011-12-01

    Maintenance of chondrocyte phenotype and robust expression and organization of macromolecular components with suitable cartilaginous properties is an ultimate goal in cartilage tissue engineering. We used a self-aggregating suspension culture (SASC) method to produce an engineered cartilage, "cartilage tissue analog" (CTA). With an objective of understanding the stability of phenotype of the CTA over long periods, we cultured chondrocytes up to 4 years and analyzed the matrix. Both early (eCTAs) (6 months) and aged (aCTAs) (4 years) showed type II collagen throughout with higher concentrations near the edge. Using Fourier transform-infrared imaging spectroscopy (FT-IRIS), proteoglycan/collagen ratio of eCTA was 2.8 times greater than native cartilage at 1 week, but the ratio was balanced to native level (p = 0.017) by 36 weeks. Surprisingly, aCTAs maintained the hyaline characteristics, but there was evidence of calcification within the tissue with a distinct range of intensities. Mineral/matrix ratio of those aCTA with "intensive" calcification was significantly higher (p = 0.017) than the "partial," but when compared to native bone the ratio of "intensive" aCTAs was 2.4 times lower. In this study we utilized the imaging approach of FT-IRIS and have shown that a biomaterial formed is compositionally closely related to natural cartilage for long periods in culture. We show that this culture platform can maintain a CTA for extended periods of time (4 years) and under those conditions signs of mineralization can be found. This method of cartilage tissue engineering is a promising method to generate cartilaginous biomaterial and may have potential to be utilized in both cartilage and boney repairs. Copyright © 2011 Orthopaedic Research Society.

  13. β-Blocker premedication does not increase the frequency of allergic reactions from coronary CT angiography: Results from the Advanced Cardiovascular Imaging Consortium.

    PubMed

    Aggarwal, Anshul; Smith, James L; Chinnaiyan, Kavitha M; Mehta, Neesurg; Boura, Judith; Khoury Abdulla, Rami; Lauter, Carl B; Raff, Gilbert L

    2015-01-01

    β-Blockers are often used for heart rate control during coronary CT angiography (CTA). Increased frequency and severity of allergic reactions to radiocontrast media (RCM) have been reported with concomitant use of β-blockers. The objectives of this study were to determine whether there is a higher incidence of allergic reactions to low-osmolar nonionic RCM in patients undergoing coronary CTA with concomitant β-blockers and to define the overall incidence and severity of allergic reactions in patients undergoing coronary CTA with and without a history of allergy to RCM. Patients undergoing coronary CTA at 47 institutions participating in the Advanced Cardiovascular Imaging Consortium registry were analyzed. The incidence and severity of allergic reactions were compared between those patients who did and those who did not receive β-blockers, as well as in subgroups of patients with and without a history of prior allergy to RCM. The incidence of allergic reaction in patients who received β-blockers was 45 of 23,867 (0.19%) compared with those who did not receive β-blockers, which was 9 of 5232 (0.17%; P = .84; odds ratio = 1.1). Of the patients with history of allergy to RCM, 4 of 706 patients (0.6%) on β-blockers experienced allergic reactions compared to 1 of 77 patients (1.3%) without β-blockers (P = .40; odds ratio = 0.43). β-Blocker pretreatment had no effect on the frequency or severity of allergic reaction in patients undergoing coronary CTA, even in patients with a past history of allergy to RCM. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  14. The anterior trochlear line as a reference for femoral component positioning in total knee arthroplasty.

    PubMed

    Morizane, Kazuki; Takahashi, Toshiaki; Konishi, Fumihiko; Yamamoto, Haruyasu

    2011-12-01

    A new radiographic method using the anterior and posterior femoral condyles as a landmark to determine the rotational alignment of the femoral component in TKA had been developed. The new radiograph presents an axial view of the distal femur. The patients were asked to lie in the supine position and flex the knee approximately 120° to 130°. Radiographs were applied at an inclination angle of 20° to 30°. The condylar twist angle (CTA), the external rotational angle between the posterior condylar (PC) line and the clinical transepicondylar axis (TEA), and the trochlear line angle (TLA), and the internal rotational angle between the anterior trochlear line and the clinical TEA were measured. Images were taken of 129 knees in 87 patients with osteoarthritis of the knee. The measurement values obtained using our method with those obtained using 3D reconstructed images from a 3-dimensional helical CT system (n = 35) were compared. The average CTA was 5.7° ± 2.8° and the average TLA was -5.6° ± 3.2°. The CTA was negatively correlated with the tibiofemoral angle (TFA). The average TLA was positively correlated with the TFA. The average difference between the TLA values obtained with this view and those obtained using the 3D-CT was 0.5° ± 1.6°. The relationship between the radiograph and 3D-CT in TLA was higher than that in CTA. This radiographic technique allows easy and simultaneous measurement of the CTA and TLA and may provide an alternative method for assessing the TEA of the femur during preoperative planning for TKA.

  15. Mortality and Rates of Secondary Intervention After EVAR in an Unselected Population: Influence of Simple Clinical Categories and Implications for Surveillance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hammond, Christopher J., E-mail: christopherhammond@nhs.net; Shah, Asim H.; Snoddon, Andrew

    IntroductionPost-EVAR surveillance has a major impact upon patients, carers and healthcare resources. We hypothesised that elective indication, on-IFU anatomy, use of a modern device or normal first CTA, or a combination of these categories, might predict a rate of secondary intervention low enough to alter current surveillance protocols.MethodsPatients undergoing EVAR in our institution between 01.05.2007 and 28.02.2013 were assessed. Data on indication (elective, emergency), anatomy relative to IFU, device, first month CTA result, secondary intervention and mortality were obtained. Kaplan–Meier charts of mortality and freedom from secondary intervention were produced. Statistical analysis was by log-rank test and Cox proportional hazardmore » modelling.Results234 patients underwent EVAR (188 elective, 208 on-IFU). Most implants were Endurant (106) or Talent (98). 151 patients had a normal first CTA. By median follow-up of 38.6 months, 39 patients underwent secondary intervention. A normal first CTA and elective indication were significantly associated with reduced risk of secondary intervention (p < 0.001 and p = 0.042 respectively), but device type and placement on- or off-IFU were not. Elective placement with a normal first CTA was 93 % predictive of freedom from secondary intervention by 32 months post-EVAR. Of nine patients undergoing secondary intervention in this group, eight presented symptomatically.DiscussionIn optimal procedural circumstances with normal post-procedural imaging, only 7 % of patients undergoing EVAR require secondary intervention, a minority of which is driven by surveillance. These data support a change to surveillance more tailored to the individual patient, and highlight the need for further qualitative and quantitative research.« less

  16. Subcutaneous Tissue Thickness is an Independent Predictor of Image Noise in Cardiac CT

    PubMed Central

    Staniak, Henrique Lane; Sharovsky, Rodolfo; Pereira, Alexandre Costa; de Castro, Cláudio Campi; Benseñor, Isabela M.; Lotufo, Paulo A.; Bittencourt, Márcio Sommer

    2014-01-01

    Background Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure. PMID:24173136

  17. Possibility of Cloudless Optical Remote Sensing Images Acquisition Study by Using Meteorological Satellite Observations

    NASA Astrophysics Data System (ADS)

    Zhang, T.; Lei, B.; Hu, Y.; Liu, K.; Gan, Y.

    2018-04-01

    Optical remote sensing images have been widely used in feature interpretation and geo-information extraction. All the fundamental applications of optical remote sensing, are greatly influenced by cloud coverage. Generally, the availability of cloudless images depends on the meteorological conditions for a given area. In this study, the cloud total amount (CTA) products of the Fengyun (FY) satellite were introduced to explore the meteorological changes in a year over China. The cloud information of CTA products were tested by using ZY-3 satellite images firstly. CTA products from 2006 to 2017 were used to get relatively reliable results. The window period of cloudless images acquisition for different areas in China was then determined. This research provides a feasible way to get the cloudless images acquisition window by using meteorological observations.

  18. Hydronephrosis by an Aberrant Renal Artery: A Case Report

    PubMed Central

    Park, Byoung Seok; Jeong, Taek Kyun; Ma, Seong Kwon; Kim, Soo Wan; Kim, Nam Ho; Choi, Ki Chul; Jeong, Yong Yeon

    2003-01-01

    Ureteropelvic junction obstruction is usually intrinsic and is most common in children. Aberrant renal arteries are present in about 30% of individuals. Aberrant renal arteries to the inferior pole cross anteriorly to the ureter and may cause hydronephrosis. To the best of our knowledge, although there are some papers about aberrant renal arteries producing ureteropelvic junction obstruction, there is no report of a case which is diagnosed by the new modalities, such as computed tomography angiogram (CTA) or magnetic resonance angiogram (MRA). We describe a 36-year-old woman with right hydronephrosis. Kidney ultrasonogram and excretory urogram revealed right hydronephrosis. CTA and MRA clearly displayed an aberrant renal artery and hydronephrosis. The patient underwent surgical exploration. For the evaluation of hydronephrosis by an aberrant renal artery, use of CTA and MRA is advocated. PMID:12760271

  19. Birefringence control of solution-cast film of cellulose triacetate

    NASA Astrophysics Data System (ADS)

    Kiyama, Ayumi; Nobukawa, Shogo; Yamaguchi, Masayuki

    2017-10-01

    We controlled the optical anisotropy of a solution-cast film composed of cellulose triacetate (CTA) by adding ferrocene. Owing to the molecular orientation in the film plane of solution-cast films, which results from the normal stress applied during the solvent evaporation process, the average refractive index is usually higher in the plane of the film than in the thickness direction. We found that the addition of ferrocene, which is miscible with CTA, reduced the optical anisotropy by nematic interaction; i.e., ferrocene molecules are forcibly embedded into the film plane accompanying the CTA chains. Because the direction of anisotropic polarizability of ferrocene is perpendicular to the long axis of the molecule, the refractive index in the thickness direction is reduced. Furthermore, the stress-optical coefficient in the glassy state is reduced by the addition of ferrocene.

  20. 76 FR 72459 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-23

    ... transfer agents to register with their Appropriate Regulatory Agency (``ARA''), whether the Commission, the... information becomes inaccurate, misleading, or incomplete. Paragraph 1 of Rule 17Ac2-1, requires transfer... ARA. Transfer agents must also file an amended Form TA-1 application for registration if the existing...

  1. 46 CFR Sec. 4 - General provisions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) All slop chest items, damaged or otherwise, shall be removed or transferred only in compliance with applicable regulations dealing with Property Removals. (b) In the transfer of a vessel from one General Agent to another General Agent the physical transfer of the complete slop chest shall also be...

  2. 46 CFR Sec. 4 - General provisions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) All slop chest items, damaged or otherwise, shall be removed or transferred only in compliance with applicable regulations dealing with Property Removals. (b) In the transfer of a vessel from one General Agent to another General Agent the physical transfer of the complete slop chest shall also be...

  3. Bacteriophage-like Particles Associated with the Gene Transfer Agent of Methanococcus Voltale PS

    NASA Technical Reports Server (NTRS)

    Bertani, G.; Eiserling, F.; Pushkin, A.; Gingery, M.

    1999-01-01

    The methanogenic archaebacterium Methanococus voltae (strain PS) is known to produce a filterable, DNase resistant agent (called VTA, for voltae transfer agent), which carries very small fragments (4,400 base pairs) of bacterial DNA and is able to transduce bacterial genes between derivatives of the strain.

  4. Participatory Design Methods for C2 Systems (Proceedings/Presentation)

    DTIC Science & Technology

    2006-01-01

    Cognitive Task Analysis (CTA) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION 18. NUMBER 19a. NAME OF RESPONSIBLE PERSON OF ABSTRACT OF PAGES Janet E. Miller...systems to support cognitive work such as is accomplished in a network-centric -environment. Cognitive task analysis (CTA) methods are used to...of cognitive task analysis methodologies exist (Schraagen et al., 2000). However, many of these methods are skeptically viewed by a domain’s

  5. AGILE detection of increasing gamma-ray activity from CTA 102

    NASA Astrophysics Data System (ADS)

    Lucarelli, F.; Verrecchia, F.; Pittori, C.; Tavani, M.; Vercellone, S.; Colafrancesco, S.; Bulgarelli, A.; Cardillo, M.; Piano, G.; Fioretti, V.; Parmiggiani, N.; Pilia, M.; Donnarumma, I.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Ferrari, A.; Paoletti, F.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.

    2017-12-01

    AGILE is detecting increasing gamma-ray emission above 100 MeV from a source positionally consistent with the FSRQ CTA 102. Integrating from 2017-12-07 06:00 UT to 2017-12-09 06:00 UT, a preliminary maximum likelihood analysis yields a detection above 6 sigma and a flux F(E > 100 MeV)=(3.6 +/- 0.9) x 10^-6 ph cm^-2 s^-1.

  6. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks.

    PubMed

    López-Linares, Karen; Aranjuelo, Nerea; Kabongo, Luis; Maclair, Gregory; Lete, Nerea; Ceresa, Mario; García-Familiar, Ainhoa; Macía, Iván; González Ballester, Miguel A

    2018-05-01

    Computerized Tomography Angiography (CTA) based follow-up of Abdominal Aortic Aneurysms (AAA) treated with Endovascular Aneurysm Repair (EVAR) is essential to evaluate the progress of the patient and detect complications. In this context, accurate quantification of post-operative thrombus volume is required. However, a proper evaluation is hindered by the lack of automatic, robust and reproducible thrombus segmentation algorithms. We propose a new fully automatic approach based on Deep Convolutional Neural Networks (DCNN) for robust and reproducible thrombus region of interest detection and subsequent fine thrombus segmentation. The DetecNet detection network is adapted to perform region of interest extraction from a complete CTA and a new segmentation network architecture, based on Fully Convolutional Networks and a Holistically-Nested Edge Detection Network, is presented. These networks are trained, validated and tested in 13 post-operative CTA volumes of different patients using a 4-fold cross-validation approach to provide more robustness to the results. Our pipeline achieves a Dice score of more than 82% for post-operative thrombus segmentation and provides a mean relative volume difference between ground truth and automatic segmentation that lays within the experienced human observer variance without the need of human intervention in most common cases. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Freeze-Dried Sulfur-Graphene Oxide-Carbon Nanotube Nanocomposite for High Sulfur-Loading Lithium/Sulfur Cells.

    PubMed

    Hwa, Yoon; Seo, Hyeon Kook; Yuk, Jong-Min; Cairns, Elton J

    2017-11-08

    The ambient-temperature rechargeable lithium/sulfur (Li/S) cell is a strong candidate for the beyond lithium ion cell since significant progress on developing advanced sulfur electrodes with high sulfur loading has been made. Here we report on a new sulfur electrode active material consisting of a cetyltrimethylammonium bromide-modified sulfur-graphene oxide-carbon nanotube (S-GO-CTA-CNT) nanocomposite prepared by freeze-drying. We show the real-time formation of nanocrystalline lithium sulfide (Li 2 S) at the interface between the S-GO-CTA-CNT nanocomposite and the liquid electrolyte by in situ TEM observation of the reaction. The combination of GO and CNT helps to maintain the structural integrity of the S-GO-CTA-CNT nanocomposite during lithiation/delithiation. A high S loading (11.1 mgS/cm 2 , 75% S) S-GO-CTA-CNT electrode was successfully prepared using a three-dimensional structured Al foam as a substrate and showed good S utilization (1128 mAh/g S corresponding to 12.5 mAh/cm 2 ), even with a very low electrolyte to sulfur weight ratio of 4. Moreover, it was demonstrated that the ionic liquid in the electrolyte improves the Coulombic efficiency and stabilizes the morphology of the Li metal anode.

  8. Best-Quality Vessel Identification Using Vessel Quality Measure in Multiple-Phase Coronary CT Angiography.

    PubMed

    Hadjiiski, Lubomir; Liu, Jordan; Chan, Heang-Ping; Zhou, Chuan; Wei, Jun; Chughtai, Aamer; Kuriakose, Jean; Agarwal, Prachi; Kazerooni, Ella

    2016-01-01

    The detection of stenotic plaques strongly depends on the quality of the coronary arterial tree imaged with coronary CT angiography (cCTA). However, it is time consuming for the radiologist to select the best-quality vessels from the multiple-phase cCTA for interpretation in clinical practice. We are developing an automated method for selection of the best-quality vessels from coronary arterial trees in multiple-phase cCTA to facilitate radiologist's reading or computerized analysis. Our automated method consists of vessel segmentation, vessel registration, corresponding vessel branch matching, vessel quality measure (VQM) estimation, and automatic selection of best branches based on VQM. For every branch, the VQM was calculated as the average radial gradient. An observer preference study was conducted to visually compare the quality of the selected vessels. 167 corresponding branch pairs were evaluated by two radiologists. The agreement between the first radiologist and the automated selection was 76% with kappa of 0.49. The agreement between the second radiologist and the automated selection was also 76% with kappa of 0.45. The agreement between the two radiologists was 81% with kappa of 0.57. The observer preference study demonstrated the feasibility of the proposed automated method for the selection of the best-quality vessels from multiple cCTA phases.

  9. Engaged at the extremes: residents' perspectives on clinical teaching assessment.

    PubMed

    Myers, Kathryn; Zibrowski, Elaine M; Lingard, Lorelei

    2012-10-01

    Although academic centers rely on assessments from medical trainees regarding the effectiveness of their faculty as teachers, little is known about how trainees conceptualize and approach their role as assessors of their clinical supervisors. In 2010, using a constructivist grounded theory approach, five focus group interviews were conducted with 19 residents from an internal medicine residency program. A constant comparative analysis of emergent themes was conducted. Residents viewed clinical teaching assessment (CTA) as a time-consuming task with little reward. They reported struggling throughout the academic year to meet their CTA obligations and described several shortcut strategies they used to reduce their burden. Rather than conceptualizing their assessments as a conduit for both formative and summative feedback, residents perceived CTA as useful for the surveillance of clinical supervisors at the extremes of the spectrum of teaching effectiveness. They put the most effort, including the crafting of written comments, into the CTAs of these outliers. Trainees desired greater transparency in the CTA process and were skeptical regarding the anonymity and perceived validity of their faculty appraisals. Individual and system-based factors conspire to influence postgraduate medical trainees' motivation for generating high-quality appraisals of clinical teaching. Academic centers need to address these factors if they want to maximize the usefulness of these assessments.

  10. Does chlorination of seawater reverse osmosis membranes control biofouling?

    PubMed

    Khan, Muhammad Tariq; Hong, Pei-Ying; Nada, Nabil; Croue, Jean Philippe

    2015-07-01

    Biofouling is the major problem of reverse osmosis (RO) membranes used for desalting seawater (SW). The use of chlorine is a conventional and common practice to control/prevent biofouling. Unlike polyamide RO membranes, cellulose triacetate (CTA) RO membranes display a high chlorine tolerance. Due to this characteristic, CTA membranes are used in most of the RO plants located in the Middle East region where the elevated seawater temperature and water quality promote the risk of membrane biofouling. However, there is no detailed study on the investigation/characterization of CTA-RO membrane fouling. In this investigation, the fouling profile of a full-scale SWRO desalination plant operating with not only continuous chlorination of raw seawater but also intermittent chlorination of CTA-RO membranes was studied. Detailed water quality and membrane fouling analyses were conducted. Profiles of microbiological, inorganic, and organic constituents of analysed fouling layers were extensively discussed. Our results clearly identified biofilm development on these membranes. The incapability of chlorination on preventing biofilm formation on SWRO membranes could be assigned to its failure in effectively reaching throughout the different regions of the permeators. This failure could have occurred due to three main factors: plugging of membrane fibers, chlorine consumption by organics accumulated on the front side fibers, or chlorine adaptation of certain bacterial populations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Flocculation and antimicrobial properties of a cationized starch.

    PubMed

    Liu, Zhouzhou; Huang, Mu; Li, Aimin; Yang, Hu

    2017-08-01

    In this study, a series of cationized starch-based flocculants (starch-3-chloro-2-hydroxypropyl triethyl ammonium chloride, St-CTA) containing various quaternary ammonium salt groups on the starch backbone were prepared using a simple etherification reaction. All of the prepared starch-based flocculants show effective performance for the flocculation of kaolin suspension, two bacterial (Escherichia coli and Staphylococcus aureus) suspensions, and two contaminant mixtures (kaolin and each bacterium) under most pH conditions. St-CTA with a high substitution degree of CTA demonstrates improved contaminant removal efficiency because of the strong cationic nature of the grafted quaternary ammonium salt groups and the charge naturalization flocculation effect. The antibacterial effects of St-CTA were also evaluated, considering that many quaternary ammonium salt compounds elicit bactericidal effects. Three-dimensional excitation-emission matrix spectra and direct cell morphological observation under scanning electron microscopy reveal that the starch-based flocculants exhibit better antibacterial effects on the Gram-negative bacterium E. coli than on the Gram-positive bacterium S. aureus. The thicker cell wall due to the presence of abundant peptidoglycan and teichoic acids of S. aureus than E. coli explains the uneasy breakage of S. aureus cell wall after being attacked by the cationized starch-based flocculants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Comparison of pain perception during miniscrew placement in orthodontic patients with a visual analog scale survey between compound topical and needle-injected anesthetics: A crossover, prospective, randomized clinical trial.

    PubMed

    Lamberton, Jordan A; Oesterle, Larry J; Shellhart, W Craig; Newman, Sheldon M; Harrell, Ricky E; Tilliss, Terri; Singh, Neha; Carey, Clifton M

    2016-01-01

    The use of a compound topical anesthetic (CTA) instead of an injection of a local anesthetic for placing miniscrew implants offers advantages to both the clinician and the patient. The purpose of this crossover, prospective, randomized clinical trial was to compare the clinical effectiveness of a CTA with that of a needle injection of local anesthetic for miniscrew placement. Twenty-four orthodontic patients in a university clinic were recruited; they required bilateral buccal miniscrews for orthodontic anchorage. Eligibility criteria included healthy patients with no special needs; over 8 years of age and 25 pounds; not taking sulfonamides, monoamine oxidase inhibitors, tricyclic antidepressants, or phenothiazines; and not allergic to ester-type local anesthetics or any of the other materials used in the study. A computer generated a randomization list. The allocation was randomized by anesthetic protocol and side of the mouth, and was restricted to achieve balance by treatment and side of the mouth. No allocation concealment was applied. Associated with each randomized number was the subjects' assignment into 1 of 4 groups divided by the side of first miniscrew placement and the type of anesthetic. Blinding was done only for data analysis because of clinical limitations. Each patient received a CTA on one side and an injection of anesthetic on the other before miniscrew placement in a crossover study design. The outcome was assessed by measuring pain levels with a 100-mm visual analog scale at 5 time points. Anesthetic failures occurred when the miniscrew could not be fully comfortably placed with a given anesthetic. Data were organized by visual analog scale time points, and descriptive statistics were calculated. A factorial repeated-measures analysis of variance was used to determine any differences. Twenty-seven patients were assessed for eligibility, and 24 agreed to participate in the study. Patients did not distinguish any differences in pain between the application of the CTA and the injection before or during anesthetic placement, but they experienced more pain with the CTA during miniscrew placement. The mean difference for the entire procedure between the 2 anesthesia types was 24.6 units, and the 95% confidence interval was 18.8 to 30.4, a statistically significant finding (P = 0.0002). The CTA was still viewed as more painful 1 month after the procedures. Significantly more anesthetic failures occurred with the CTA (41.6%) than with the injection (0%). No serious harm was observed in any patient; when significant pain was observed with the CTA, a needle injection of local anesthetic was administered. CTAs provided less predictable, often inadequate, and less comfortable anesthesia than an injection of a local anesthetic for managing patient discomfort during miniscrew placement in buccal sites. This trial was not registered. The protocol was determined and approved by the research committee and institutional review board before the trial. No external funding was used other than the donation of the miniscrews from Rocky Mountain Orthodontics, and no conflict of interest was declared. Copyright © 2016. Published by Elsevier Inc.

  13. Validating Human Behavioral Models for Combat Simulations Using Techniques for the Evaluation of Human Performance

    DTIC Science & Technology

    2004-01-01

    Cognitive Task Analysis Abstract As Department of Defense (DoD) leaders rely more on modeling and simulation to provide information on which to base...capabilities and intent. Cognitive Task Analysis (CTA) Cognitive Task Analysis (CTA) is an extensive/detailed look at tasks and subtasks performed by a...Domain Analysis and Task Analysis: A Difference That Matters. In Cognitive Task Analysis , edited by J. M. Schraagen, S.

  14. The Effect of a Computerized Teaching Assistant on Student Interaction, Student Satisfaction, and Retention Rates of Students in a Distance Course

    ERIC Educational Resources Information Center

    Reindl-Johnson, Cheryl

    2004-01-01

    The purpose of this study was to investigate the effect of a computerized teaching assistant (CTA) on student interaction, student satisfaction, and retention rates of students in a distance course. The CTA is humanoid and speaks in a human voice from recorded sound clips, to give the student the feeling that he/she is interacting with a person,…

  15. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation.

    PubMed

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-08

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a 'false-negative' result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death.

  16. Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation

    PubMed Central

    Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George

    2013-01-01

    We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a ‘false-negative’ result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death. PMID:23302550

  17. Publication trends of Allergy, Pediatric Allergy and Immunology, and Clinical and Translational Allergy journals: a MeSH term-based bibliometric analysis.

    PubMed

    Martinho-Dias, Daniel; Sousa-Pinto, Bernardo; Botelho-Souza, Júlio; Soares, António; Delgado, Luís; Fonseca, João Almeida

    2018-01-01

    We performed a MeSH term-based bibliometric analysis aiming to assess the publication trends of EAACI journals, namely Allergy, Pediatric Allergy and Immunology (PAI) (from 1990 to 2015) and Clinical and Translational Allergy (CTA) (from its inception in 2011 to 2015). We also aimed to discuss the impact of the creation of CTA in the publication topics of Allergy and PAI. We analysed a total of 1973 articles and 23,660 MeSH terms. Most MeSH terms in the three journals fell in the category of "basic immunology and molecular biology" (BIMB). During the studied period, we observed an increase in the proportion of MeSH terms on BIMB, and a decreasing proportion of terms on allergic rhinitis and aeroallergens. The observed changes in Allergy and PAI publication topics hint at a possible impact from CTA creation.

  18. 77 FR 3291 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ... of 1934 (15 U.S.C. 78a et seq.) (``Exchange Act''). Rule 17Ac2-2 and Form TA-2 require transfer... requirements are designed to ensure that all registered transfer agents are providing the Commission with sufficient information on an annual basis about the transfer agent community and for the Commission to...

  19. Synthesis and characterization of functional acrylic copolymers via RAFT mini-emulsion polymerization

    NASA Astrophysics Data System (ADS)

    Yılmaz, Onur; Özkan, ćiǧdem Kılıçarislan; Yılmaz, Catalina N.; Yorgancıoǧlu, Ali; Özgünay, Hasan; Karavana, Hüseyin Ata

    2017-12-01

    Copolymers bearing reactive functional groups with controlled molecular weights are of importance since they can be used in many fields such as composites, coatings, membranes, catalysis, biology, optoelectronics, pharmaceuticals, etc. In the present study low molecular weight copolymers based on butyl acrylate (BA) and methyl methacrylate (MMA) in combination with reactive functional monomers of vinyl trietoxysilane (VTES), 3-trimetoxysilylpropyl methacrylate (TMSPMA) and glycidyl methacrylate (GMA) were synthesized via RAFT mini-emulsion technique using 2-cyano 2-propyldodecyldithiocarbonate as CTA agent. The results showed that the average molecular weights of copolymers were close to the theoretical values. On the other hand, PDI values were found to be higher than conventional RAFT polymers. The particle sizes of the latexes were small with very homogenous distributions and good stability. FTIR, H-NMR and TGA results verified the success of copolymer syntheses.

  20. Requirements for facilities transferring or receiving select agents. Final rule.

    PubMed

    2001-08-31

    CDC administers regulations that govern the transfer of certain biological agents and toxins ("select agents"). These regulations require entities that transfer or receive select agents to register with CDC and comply with biosafety standards contained in the Third Edition of the CDC/NIH publication "Biosafety in Microbiological and Biomedical Laboratories ("BMBL")." On October 28,1999, CDC published a Notice of Proposed Rulemaking ("NPRM") seeking both to revise the biosafety standards facilities must follow when handling select agents and to provide new biosecurity standards for such facilities. These new standards are contained in the Fourth Edition of BMBL, which the NPRM proposed to incorporate by reference, thereby replacing the Third Edition. No comments were received in response to this proposal. CDC is therefore amending its regulations to incorporate the Fourth Edition.

  1. Impact of Contrast Media Concentration on Low-Kilovolt Computed Tomography Angiography: A Systematic Preclinical Approach.

    PubMed

    Fleischmann, Ulrike; Pietsch, Hubertus; Korporaal, Johannes G; Flohr, Thomas G; Uder, Michael; Jost, Gregor; Lell, Michael M

    2018-05-01

    Low peak kilovoltage (kVp) protocols in computed tomography angiography (CTA) demand a review of contrast media (CM) administration practices. The aim of this study was to systematically evaluate different iodine concentrations of CM in a porcine model. Dynamic 70 kVp CTA was performed on 7 pigs using a third-generation dual-source CT system. Three CM injection protocols (A-C) with an identical total iodine dose and iodine delivery rate (150 mg I/kg, 12 s, 0.75 g I/s) differed in iodine concentration and flow rate (protocol A: 400 mg I/mL, 1.9 mL/s; B: 300 mg I/mL, 2.5 mL/s; C: 150 mg I/mL, 5 mL/s). All protocols were applied in a randomized order and compared intraindividually. Arterial enhancement at different locations in the pulmonary artery, the aorta, and aortic branches was measured over time. Time attenuation curves, peak enhancement, time to peak, and bolus tracking delay times needed for static CTA were calculated. The reproducibility of optimal parameters was tested in single-phase CTA. The heart rates of the pigs were comparable for all protocols (P > 0.7). The injection pressure was significantly higher for protocol A (64 ± 5 psi) and protocol C (55 ± 3 psi) compared with protocol B (39 ± 2 psi) (P < 0.001). Average arterial peak enhancement in the dynamic scans was 359 ± 51 HU (protocol A), 382 ± 36 HU (B), and 382 ± 60 HU (C) (A compared with B and C: P < 0.01; B compared with C: P = 0.995). Time to peak enhancement decreased with increasing injection rate. The delay time for bolus tracking depended on the injection rate as well and was highest for protocol A (4.7 seconds) and lowest for protocol C (3.9 seconds) (P = 0.038). The peak enhancement values of the dynamic scans highly correlated with those of the single-phase CTA scans. In 70 kVp CTA, 300 mg I/mL iodine concentrations showed to be superior to high-concentration CM when keeping the iodine delivery rate constant. Besides, iodine concentrations as low as 150 mg I/mL can be administered without compromising vascular enhancement. This opens up new possibilities in CM administration.

  2. Interannual Variability in Global Dust Storm Initiation on Mars from a GCM with Orbit-Spin Coupling and Active Dust Lifting

    NASA Astrophysics Data System (ADS)

    Mischna, M.; Shirley, J. H.; Newman, C. E.

    2016-12-01

    To first order, the occurrence and interannual variability of global dust storms (GDS) on Mars is attributable to two factors: the annual cycle of solar insolation (which delineates a specific `dust storm season'), and the changing spatial distribution and availability of dust at the surface. Recent work has now found a remarkable correspondence between the occurrence of GDS on Mars and years in which the orbital angular momentum of Mars is increasing during the dust storm season. A previously undefined acceleration term `couples' this orbital motion to the rotational motion of the planet and atmosphere, and small but persistent atmospheric accelerations (so-called `coupling term accelerations,' or CTA) change the atmospheric circulation in such a way as to seemingly be favorable to storm development. This becomes a third factor, then, that may regulate the occurrence and variability of GDS. Our prior work with the MarsWRF general circulation model (GCM) was performed either with no atmospheric dust, or with simplified, prescribed dust distributions, and illustrated the dual roles of both insolation and CTA on GDS variability. Recent advances in the MarsWRF GCM dust prescription can now tackle the remaining unaddressed factor: the role of dust availability in controlling the initiation of GDS. Simulations with both infinite and finite global sources of dust have been performed. For a prescribed dust lifting threshold, surface dust is removed from the surface, preferentially from locations with larger surface stress values, transported in the atmosphere and deposited at a later time. Compared to simulations without CTA, those with CTA show more realism in the variability of timing and magnitude of atmospheric dustiness during the dust storm season. For infinite surface dust, the primary dust lifting (peak wind stress) regions are spatially restricted, and year-to-year changes are largely due to variations in the CTA at these few locations. By contrast, in simulations with finite surface dust, the peak stress regions are rapidly exhausted, leading to a far greater distribution of primary dust lifting regions; hence, variations in the CTA over a wider area contribute to the interannual variability of GDS. Results from our suite of simulations will be shown, vis-à-vis the historical record of GDS on Mars.

  3. Feasibility of low contrast media volume in CT angiography of the aorta.

    PubMed

    Seehofnerová, Anna; Kok, Madeleine; Mihl, Casper; Douwes, Dave; Sailer, Anni; Nijssen, Estelle; de Haan, Michiel J W; Wildberger, Joachim E; Das, Marco

    2015-01-01

    Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. 77 patients referred for CTA of the aorta were scanned using a standard MDCT protocol at 100 kV. A bolus of 50 ml CM (Iopromide 300 mg Iodine/ml) at a flow rate of 6 ml/s was applied (Iodine delivery rate IDR = 1.8 g/s; Iodine load 15 g) followed by a saline bolus of 40 ml at the same flow rate. Scan delay was determined by the test bolus method. Subjective image quality was assessed and contrast enhancement was measured at 10 anatomical levels of the aorta. Diagnostic quality images were obtained for all patients, reaching a mean overall contrast enhancement of 324 ± 28 HU. Mean attenuation was 350 ± 60 HU at the thoracic aorta and 315 ± 83 HU at the abdominal aorta. A straightforward low volume CM protocol proved to be technically feasible and led to CTA examinations reaching diagnostic image quality of the aorta at 100 kV. Based on these findings, the use of a relatively small CM bolus can be incorporated into routine clinical imaging.

  4. Correlation Between Activation of the Prelimbic Cortex, Basolateral Amygdala, and Agranular Insular Cortex During Taste Memory Formation.

    PubMed

    Uematsu, Akira; Kitamura, Akihiko; Iwatsuki, Ken; Uneyama, Hisayuki; Tsurugizawa, Tomokazu

    2015-09-01

    Conditioned taste aversion (CTA) is a well-established learning paradigm, whereby animals associate tastes with subsequent visceral illness. The prelimbic cortex (PL) has been shown to be involved in the association of events separated by time. However, the nature of PL activity and its functional network in the whole brain during CTA learning remain unknown. Here, using awake functional magnetic resonance imaging and fiber tracking, we analyzed functional brain connectivity during the association of tastes and visceral illness. The blood oxygen level-dependent (BOLD) signal significantly increased in the PL after tastant and lithium chloride (LiCl) infusions. The BOLD signal in the PL significantly correlated with those in the amygdala and agranular insular cortex (IC), which we found were also structurally connected to the PL by fiber tracking. To precisely examine these data, we then performed double immunofluorescence with a neuronal activity marker (c-Fos) and an inhibitory neuron marker (GAD67) combined with a fluorescent retrograde tracer in the PL. During CTA learning, we found an increase in the activity of excitatory neurons in the basolateral amygdala (BLA) or agranular IC that project to the PL. Taken together, these findings clearly identify a role of synchronized PL, agranular IC, and BLA activity in CTA learning. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  5. CREB regulates memory allocation in the insular cortex

    PubMed Central

    Sano, Yoshitake; Shobe, Justin L.; Zhou, Miou; Huang, Shan; Shuman, Tristan; Cai, Denise J.; Golshani, Peyman; Kamata, Masakazu; Silva, Alcino J.

    2016-01-01

    Summary The molecular and cellular mechanisms of memory storage have attracted a great deal of attention. By comparison, little is known about memory allocation, the process that determines which specific neurons in a neural network will store a given memory [1, 2]. Previous studies demonstrated that memory allocation is not random in the amygdala; these studies showed that amygdala neurons with higher levels of the cAMP response element binding protein (CREB) are more likely to be recruited into encoding and storing fear memory [3–6]. To determine whether specific mechanisms also regulate memory allocation in other brain regions, and whether CREB also has a role in this process, we studied insular cortical memory representations for conditioned taste aversion (CTA). In this task, an animal learns to associate a taste (CS) with the experience of malaise (such as that induced by LiCl; US). The insular cortex is required for CTA memory formation and retrieval [7–12]. CTA learning activates a subpopulation of neurons in this structure [13–15], and the insular cortex and the basolateral amygdala (BLA) interact during CTA formation [16, 17]. Here, we used a combination of approaches, including viral vector transfections of insular cortex, arc Fluorescence In Situ Hybridization (FISH) and Designer Receptors Exclusively Activated by Designer Drugs (DREADD) system, to show that CREB levels determine which insular cortical neurons go on to encode a given conditioned taste memory. PMID:25454591

  6. The use of intraosseous needles for injection of contrast media for computed tomographic angiography of the thoracic aorta.

    PubMed

    Winkler, Michael; Talley, Cynthia; Woodward, Connor; Kingsbury, Alexander; Appiah, Frank; Elbelasi, Hossam; Landwher, Kevin; Li, Xingzhe; Fleischmann, Dominik

    The objective of this study is to evaluate the safety and quality of computed tomographic angiography of the thoracic aorta (CTA-TA) exams performed using intraosseous needle intravenous access (ION-IVA) for contrast media injection (CMI). All CTA-TA exams at the study institution performed between 1/1/2013 and 8/14/2015 were reviewed retrospectively to identify those exams which had been performed using ION-IVA (ION-exams). ION-exams were then analyzed to determine aortic attenuation and contrast-to-noise ratio (CNR). Linear regression was used to determine how injection rate and other variables affected image quality for ION-exams. Patient electronic medical records were reviewed to identify any adverse events related to CTA-TA or ION-IVA. 17 (∼0.2%) of 7401 exams were ION-exams. ION-exam CMI rates varied between 2.5 and 4 ml/s. Mean attenuation was 312 HU (SD 88 HU) and mean CNR was 25 (SD 9.9). A strong positive linear association between attenuation and injection rate was found. No immediate or delayed complications related to the ION-exams, or intraosseous needle use in general, occurred. For CTA-TA, ION-IVA appears to be a safe and effective route for CMI at rates up to 4 ml/s. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Insulin-IGF signaling affects cell transformation in the BALB/c 3T3 cell model

    PubMed Central

    Poburski, Doerte; Leovsky, Christiane; Boerner, Josefine Barbara; Szimmtenings, Luisa; Ristow, Michael; Glei, Michael; Thierbach, René

    2016-01-01

    The increased cancer mortality of diabetes type 2 patients is most likely an evidence of the tight connection between tumor development and energy metabolism. A major focus of today’s research is still the identification of key proteins of both diseases and the development of corresponding inhibitors. In this study we combined the two-stage BALB/c-3T3 cell transformation assay (BALB-CTA) with the IR/IGF-1R inhibitor OSI-906 (linsitinib) and analyzed alterations in protein activity and energy parameters in non-transformed as well as transformed cells. OSI-906 successfully inhibited the phosphorylation of IR/IGF-1R and decreased cell growth in non-transformed cells. In the BALB-CTA, a permanent treatment with OSI-906 reduced cellular transformation dose-dependently, whereas a temporary treatment gave evidence for a preventive effect in the promotion phase. Furthermore, even though several key proteins were affected, it was possible to show that the phosphorylation of GSK3, Erk 1/2 and the S6 protein are not crucial for the cell foci reducing effect of OSI-906. Taken together, the BALB-CTA confirmed results of OSI-906 from animal studies and enhanced the knowledge of its mode of action. Therefore, the BALB-CTA offers the opportunity to analyze alterations in the transformation process more precisely and will be helpful to identify effective cancer treatments. PMID:27849005

  8. Insulin-IGF signaling affects cell transformation in the BALB/c 3T3 cell model.

    PubMed

    Poburski, Doerte; Leovsky, Christiane; Boerner, Josefine Barbara; Szimmtenings, Luisa; Ristow, Michael; Glei, Michael; Thierbach, René

    2016-11-16

    The increased cancer mortality of diabetes type 2 patients is most likely an evidence of the tight connection between tumor development and energy metabolism. A major focus of today's research is still the identification of key proteins of both diseases and the development of corresponding inhibitors. In this study we combined the two-stage BALB/c-3T3 cell transformation assay (BALB-CTA) with the IR/IGF-1R inhibitor OSI-906 (linsitinib) and analyzed alterations in protein activity and energy parameters in non-transformed as well as transformed cells. OSI-906 successfully inhibited the phosphorylation of IR/IGF-1R and decreased cell growth in non-transformed cells. In the BALB-CTA, a permanent treatment with OSI-906 reduced cellular transformation dose-dependently, whereas a temporary treatment gave evidence for a preventive effect in the promotion phase. Furthermore, even though several key proteins were affected, it was possible to show that the phosphorylation of GSK3, Erk 1/2 and the S6 protein are not crucial for the cell foci reducing effect of OSI-906. Taken together, the BALB-CTA confirmed results of OSI-906 from animal studies and enhanced the knowledge of its mode of action. Therefore, the BALB-CTA offers the opportunity to analyze alterations in the transformation process more precisely and will be helpful to identify effective cancer treatments.

  9. Enhancement of Inhibitory Avoidance and Conditioned Taste Aversion Memory With Insular Cortex Infusions of 8-Br-cAMP: Involvement of the Basolateral Amygdala

    PubMed Central

    Miranda, María I.; McGaugh, James L.

    2004-01-01

    There is considerable evidence that in rats, the insular cortex (IC) and amygdala are involved in the learning and memory of aversively motivated tasks. The present experiments examined the effects of 8-Br-cAMP, an analog of cAMP, and oxotremorine, a muscarinic agonist, infused into the IC after inhibitory avoidance (IA) training and during the acquisition/consolidation of conditioned taste aversion (CTA). Posttraining infusion into the IC of 0.3 μg oxotremorine and 1.25 μg 8-Br-cAMP enhanced IA retention. Infusions of 8-Br-cAMP, but not oxotremorine, into the IC enhanced taste aversion. The experiments also examined whether noradrenergic activity in the basolateral amygdala (BLA) is critical in enabling the enhancement of CTA and IA memory induced by drug infusions administered into the IC. For both CTA and IA, ipsilateral infusions of β-adrenergic antagonist propranolol administered into the BLA blocked the retention-enhancing effect of 8-Br-cAMP or oxotremorine infused into the IC. These results indicate that the IC is involved in the consolidation of memory for both IA and CTA, and this effect requires intact noradrenergic activity into the BLA. These findings provide additional evidence that the BLA interacts with other brain regions, including sensory cortex, in modulating memory consolidation. PMID:15169861

  10. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    PubMed

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  11. Underestimation of myocardial blood flow by dynamic perfusion CT: Explanations by two-compartment model analysis and limited temporal sampling of dynamic CT.

    PubMed

    Ishida, Masaki; Kitagawa, Kakuya; Ichihara, Takashi; Natsume, Takahiro; Nakayama, Ryohei; Nagasawa, Naoki; Kubooka, Makiko; Ito, Tatsuro; Uno, Mio; Goto, Yoshitaka; Nagata, Motonori; Sakuma, Hajime

    2016-01-01

    Previous studies using dynamic perfusion CT and volume perfusion CT (VPCT) software consistently underestimated the stress myocardial blood flow (MBF) in normal myocardium to be 1.1-1.4 ml/min/g, whilst the O 15-water PET studies demonstrated the normal stress MBF of 3-5 ml/min/g. We hypothesized that the MBF determined by VPCT (MBF-VPCT) is actually presenting the blood-to-myocardium transfer constant, K1. In this study, we determined K1 using Patlak plot (K1-Patlak) and compared the results with MBF-VPCT. 17 patients (66 ± 9 years, 7 males) with suspected coronary artery disease (CAD) underwent stress dynamic perfusion CT, followed by rest coronary CT angiography (CTA). Arterial input and myocardial output curves were analyzed with Patlak plot to quantify myocardial K1. Significant CAD was defined as >50% stenosis on CTA. A simulation study was also performed to investigate the influence of limited temporal sampling in dynamic CT acquisition on K1 using the undersampling data generated from MRI. There were 3 patients with normal CTA, 7 patients with non-significant CAD, and 7 patients with significant CAD. K1-patlak was 0.98 ± 0.35 (range 0.22-1.67) ml/min/g, whereas MBF-VPCT was 0.83 ± 0.23 (range 0.34-1.40) ml/min/g. There was a linear relationship between them: (MBF-VPCT) = 0.58 x (K1-patlak) + 0.27 (r(2) = 0.65, p < 0.001). The simulation study done on MRI data demonstrated that Patlak plot substantially underestimated true K1 by 41% when true K1 was 2.0 ml/min/g with the temporal sampling of 2RR for arterial input and 4RR for myocardial output functions. The results of our study are generating hypothesis that MBF-VPCT is likely to be calculating K1-patlak equivalent, not MBF. In addition, these values may be substantially underestimated because of limited temporal sampling rate. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  12. Stabilizing the boundary between US politics and science: the role of the Office of Technology Transfer as a boundary organization.

    PubMed

    Guston, D H

    1999-02-01

    The sociological study of boundary-work and the political-ecomomic approach of principal-agent theory can be complementary ways of examining the relationship between society and science: boundary-work provides the empirical nuance to the principal-agent scheme, and principal-agent theory provides structure to the thick boundary description. This paper motivates this complementarity to examine domestic technology transfer in the USA from the intramural laboratories of the US National Institutes of Health (NIH). It casts US policy for technology transfer in the principal-agent framework, in which politicians attempt to manage the moral hazard of the productivity of research by providing specific incentives to the agents for engaging in measurable research-based innovation. Such incentives alter the previously negotiated boundary between politics and science. The paper identifies the crucial role of the NIH Office of Technology Transfer (OTT) as a boundary organization, which medicates the new boundary negotiations in its routine work, and stabilizes the boundary by performing successfully as an agent for both politicians and scientists. The paper hypothesizes that boundary organizations like OTT are general phenomena at the boundary between politics and science.

  13. Impact of Coronary Calcification on Clinical Management in Patients With Acute Chest Pain

    PubMed Central

    Bittner, Daniel O.; Mayrhofer, Thomas; Bamberg, Fabian; Hallett, Travis R.; Janjua, Sumbal; Addison, Daniel; Nagurney, John T.; Udelson, James E.; Lu, Michael T.; Truong, Quynh A.; Woodard, Pamela K.; Hollander, Judd E.; Miller, Chadwick; Chang, Anna Marie; Singh, Harjit; Litt, Harold; Hoffmann, Udo; Ferencik, Maros

    2018-01-01

    Background Coronary artery calcification (CAC) may impair diagnostic assessment of coronary computed tomography angiography (CTA). We determined whether CAC affects efficiency of coronary CTA in patients with suspected acute coronary syndrome (ACS). Methods and Results This is a pooled analysis of ACRIN-PA-4005 and ROMICAT-II trial comparing an initial coronary CTA strategy to standard of care in acute chest pain patients. In the CTA arms, we investigated appropriateness of downstream testing, cost and diagnostic yield to identify patients with obstructive coronary artery disease (CAD) on subsequent invasive coronary angiography (ICA) across CAC score strata (Agatston score: 0, >0–10, >10–100, >100–400, >400). Out of 1,234 patients (mean age 51±8.8 years), 80 (6.5%) had obstructive CAD (≥70% stenosis), and 68 (5.5%) had ACS. Prevalence of obstructive CAD (1% to 64%), ACS (1% to 44%), downstream testing (4% to 72%), total (2337 US$ to 8484 US$) and diagnostic cost (2310 US$ to 6678 US$) increased across CAC strata (p<0.001). As the increase in testing and cost were lower than the increase of ACS rate in patients with CAC>400, cost to diagnose one ACS was lowest in this group (19,283 US$ vs. 464,399 US$) as compared to patients without CAC. The diagnostic yield of ICA was highest in patients with CAC>400 (87% vs. 38%). Conclusion Downstream testing, total and diagnostic cost increased with increasing CAC, but were found to be appropriate, as obstructive CAD and ACS were more prevalent in patients with high CAC. In patients with acute chest pain undergoing coronary CTA, cost efficient testing and excellent diagnostic yield can be achieved even with high CAC burden. Clinical Trial Registration Information URL: https://clinicaltrials.gov. Unique identifier: NCT01084239 and NCT00933400. PMID:28487318

  14. Is higher body temperature beneficial in ischemic stroke patients with normal admission CT angiography of the cerebral arteries?

    PubMed Central

    Kvistad, Christopher Elnan; Khanevski, Andrej; Nacu, Aliona; Thomassen, Lars; Waje-Andreassen, Ulrike; Naess, Halvor

    2014-01-01

    Background Low body temperature is considered beneficial in ischemic stroke due to neuroprotective mechanisms, yet some studies suggest that higher temperatures may improve clot lysis and outcomes in stroke patients treated with tissue plasminogen activator (tPA). The effect of increased body temperature in stroke patients treated with tPA and with normal computed tomography angiography (CTA) on admission is unknown. We hypothesized a beneficial effect of higher body temperature in the absence of visible clots on CTA, possibly due to enhanced lysis of small, peripheral clots. Methods Patients with ischemic stroke admitted to our Stroke Unit between February 2006 and April 2013 were prospectively registered in a database (Bergen NORSTROKE Registry). Ischemic stroke patients treated with tPA with normal CTA of the cerebral arteries were included. Outcomes were assessed by the modified Rankin Scale (mRS) after 1 week. An excellent outcome was defined as mRS=0, and a favorable outcome as mRS=0–1. Results A total of 172 patients were included, of which 48 (27.9%) had an admission body temperature ≥37.0°C, and 124 (72.1%) had a body temperature <37.0°C. Body temperature ≥37.0°C was independently associated with excellent outcomes (odds ratio [OR]: 2.8; 95% confidence interval [CI]: 1.24–6.46; P=0.014) and favorable outcomes (OR: 2.8; 95% CI: 1.13–4.98; P=0.015) when adjusted for confounders. Conclusion We found an association between higher admission body temperature and improved outcome in tPA-treated stroke patients with normal admission CTA of the cerebral arteries. This may suggest a beneficial effect of higher body temperature on clot lysis in the absence of visible clots on CTA. PMID:24482573

  15. Computational high-resolution heart phantoms for medical imaging and dosimetry simulations

    NASA Astrophysics Data System (ADS)

    Gu, Songxiang; Gupta, Rajiv; Kyprianou, Iacovos

    2011-09-01

    Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are rendered under fluoroscopic guidance. Both invasive and non-invasive imaging modalities employ ionizing radiation and there is concern for deterministic and stochastic effects of radiation. Accurate simulation to optimize image quality with minimal radiation dose requires detailed, gender-specific anthropomorphic phantoms with anatomically correct heart and associated vasculature. Such phantoms are currently unavailable. This paper describes an open source heart phantom development platform based on a graphical user interface. Using this platform, we have developed seven high-resolution cardiac/coronary artery phantoms for imaging and dosimetry from seven high-quality CTA datasets. To extract a phantom from a coronary CTA, the relationship between the intensity distribution of the myocardium, the ventricles and the coronary arteries is identified via histogram analysis of the CTA images. By further refining the segmentation using anatomy-specific criteria such as vesselness, connectivity criteria required by the coronary tree and image operations such as active contours, we are able to capture excellent detail within our phantoms. For example, in one of the female heart phantoms, as many as 100 coronary artery branches could be identified. Triangular meshes are fitted to segmented high-resolution CTA data. We have also developed a visualization tool for adding stenotic lesions to the coronaries. The male and female heart phantoms generated so far have been cross-registered and entered in the mesh-based Virtual Family of phantoms with matched age/gender information. Any phantom in this family, along with user-defined stenoses, can be used to obtain clinically realistic projection images with the Monte Carlo code penMesh for optimizing imaging and dosimetry.

  16. New electronics for the Cherenkov Telescope Array (NECTAr)

    NASA Astrophysics Data System (ADS)

    Naumann, C. L.; Delagnes, E.; Bolmont, J.; Corona, P.; Dzahini, D.; Feinstein, F.; Gascón, D.; Glicenstein, J.-F.; Guilloux, F.; Nayman, P.; Rarbi, F.; Sanuy, A.; Tavernet, J.-P.; Toussenel, F.; Vincent, P.; Vorobiov, S.

    2012-12-01

    The international CTA consortium has recently entered into its preparatory phase towards the construction of the next-generation Cherenkov Telescope Array CTA. This experiment will be a successor, and based on the return of experience from the three major current-generation arrays H.E.S.S., MAGIC and VERITAS, and aims to significantly improve upon the sensitivity as well as the energy range of its highly successful predecessors. Construction is planned to begin by 2013, and when finished, CTA will be able to explore the highest-energy gamma ray sky in unprecedented detail. To achieve this increase in sensitivity and energy range, CTA will employ the order of 100 telescopes of three different sizes on two sites, with around 1000-4000 channels per camera, depending on the telescope size. To equip and reliably operate the order of 100000 channels of photodetectors (compared to 6000 of the H.E.S.S. array), a new kind of flexible and powerful yet inexpensive front-end hardware will be required. One possible solution is pursued by the NECTAr (New Electronics for the Cherenkov Telescope Array) project. Its main feature is the integration of as much as possible of the front-end electronics (amplifiers, fast analogue samplers, memory and ADCs) into a single ASIC, which will allow very fast readout performances while significantly reducing the cost and the power consumption per channel. Also included is a low-cost FPGA for digital treatment and online data processing, as well as an Ethernet connection. Other priorities of NECTAr are the modularity of the system, a high degree of flexibility in the trigger system as well as the possibility of flexible readout modes to optimise the signal-to-noise ratio while at the same time allowing a significant reduction of data rates, both of which could improve the sensitivity of CTA compared to current detection systems. This paper gives an overview over the development work for the Nectar system, with particular focus on its main component, the NECTAr ASIC.

  17. iPad-based primary 2D reading of CT angiography examinations of patients with suspected acute gastrointestinal bleeding: preliminary experience.

    PubMed

    Faggioni, L; Neri, E; Bargellini, I; Scalise, P; Calcagni, F; Mantarro, A; D'Ippolito, G; Bartolozzi, C

    2015-03-01

    To evaluate the effectiveness of the iPad (Apple Inc., Cupertino, CA) for two-dimensional (2D) reading of CT angiography (CTA) studies performed for suspected acute non-variceal gastrointestinal bleeding. 24 CTA examinations of patients with suspected acute gastrointestinal bleeding confirmed (19/24, 79.2%) or ruled out (5/24, 20.8%) by digital subtraction angiography (DSA) were retrospectively reviewed by three independent readers on a commercial picture archiving communication system (PACS) workstation and on an iPad with Retina Display® 64 GB (Apple Inc.). The time needed to complete reading of every CTA examination was recorded, as well as the rate of detection of arterial bleeding and identification of suspected bleeding arteries on both devices. Overall, the area under the receiver operating characteristic curve, sensitivity, specificity, positive- and negative-predictive values for bleeding detection were not significantly different while using the iPad and workstation (0.774 vs 0.847, 0.947 vs 0.895, 0.6 vs 0.8, 0.9 vs 0.944 and 0.750 vs 0.667, respectively; p > 0.05). In DSA-positive cases, the iPad and workstation allowed correct identification of the bleeding source in 17/19 cases (89.5%) and 15/19 cases (78.9%), respectively (p > 0.05). Finally, the time needed to complete reading of every CTA study was significantly shorter using the iPad (169 ± 74 vs 222 ± 70 s, respectively; p < 0.01). Compared with a conventional PACS workstation, iPad-based preliminary 2D reading of CTA studies has comparable diagnostic accuracy for detection of acute gastrointestinal bleeding and can be significantly faster. The iPad could be used by on-call interventional radiologists for immediate decision on percutaneous embolization in patients with suspected acute gastrointestinal bleeding.

  18. Diagnostic performance of focused cardiac ultrasound performed by emergency physicians for the assessment of ascending aorta dilation and aneurysm.

    PubMed

    Nazerian, Peiman; Vanni, Simone; Morello, Fulvio; Castelli, Matteo; Ottaviani, Maddalena; Casula, Claudia; Petrioli, Alessandra; Bartolucci, Maurizio; Grifoni, Stefano

    2015-05-01

    The diagnostic performance of transthoracic focused cardiac ultrasound (FoCUS) performed by emergency physicians (EP) to estimate ascending aorta dimensions in the acute setting has not been prospectively studied. The diagnostic accuracy and the interobserver variability of EP-performed FoCUS were investigated to estimate thoracic aortic dilation and aneurysm compared with the results of computed tomography angiography (CTA). This was a prospective single-center cohort study of a convenience sample of patients who underwent CTA in the emergency department for suspected aortic pathology. FoCUS was performed before CTA, and the maximum ascending aorta diameter evaluated in parasternal long-axis view. Aorta diameter < 40 mm by visual estimation or by diameter measurement was considered normal. Measurements were recorded in all patients with aorta diameter ≥ 40 mm. Diagnostic accuracy of FoCUS for detection of aortic dilation (diameter ≥ 40 mm) and aneurysm (diameter ≥ 45 mm) were calculated considering the CTA result as reference standard. In a subgroup of patients, a second EP-sonographer performed FoCUS to evaluate interobserver agreement for the diagnosis of ascending aorta dilation. A total of 140 patients were enrolled in the study. Ascending aorta dilation and aneurysm were detected with FoCUS in 50 (35.7%) and in 27 (17.8%) patients, respectively. Sensitivity and specificity of FoCUS were 78.6% (95% confidence interval [CI] = 65.6% to 88.4%) and 92.9% (95% CI = 85.1% to 97.3%), respectively, for ascending aorta dilation and 64.7% (95% CI = 46.5% to 80.2%) and 95.3% (95% CI = 89.3% to 98.4%), respectively, for ascending aorta aneurysm. Interobserver agreement of FoCUS was k = 0.82. FoCUS performed by EP is specific for ascending aorta dilation and aneurysm when compared to CTA and appears a reproducible technique. © 2015 by the Society for Academic Emergency Medicine.

  19. The control system of the 12-m medium-size telescope prototype: a test-ground for the CTA array control

    NASA Astrophysics Data System (ADS)

    Oya, I.; Anguner, E. A.; Behera, B.; Birsin, E.; Fuessling, M.; Lindemann, R.; Melkumyan, D.; Schlenstedt, S.; Schmidt, T.; Schwanke, U.; Sternberger, R.; Wegner, P.; Wiesand, S.

    2014-07-01

    The Cherenkov Telescope Array (CTA) will be the next generation ground-based very-high energy -ray observatory. CTA will consist of two arrays: one in the Northern hemisphere composed of about 20 telescopes, and the other one in the Southern hemisphere composed of about 100 telescopes, both arrays containing telescopes of different sizes and types and in addition numerous auxiliary devices. In order to provide a test-ground for the CTA array control, the steering software of the 12-m medium size telescope (MST) prototype deployed in Berlin has been implemented using the tools and design concepts under consideration to be used for the control of the CTA array. The prototype control system is implemented based on the Atacama Large Millimeter/submillimeter Array (ALMA) Common Software (ACS) control middleware, with components implemented in Java, C++ and Python. The interfacing to the hardware is standardized via the Object Linking and Embedding for Process Control Unified Architecture (OPC UA). In order to access the OPC UA servers from the ACS framework in a common way, a library has been developed that allows to tie the OPC UA server nodes, methods and events to the equivalents in ACS components. The front-end of the archive system is able to identify the deployed components and to perform the sampling of the monitoring points of each component following time and value change triggers according to the selected configurations. The back-end of the archive system of the prototype is composed by two different databases: MySQL and MongoDB. MySQL has been selected as storage of the system configurations, while MongoDB is used to have an efficient storage of device monitoring data, CCD images, logging and alarm information. In this contribution, the details and conclusions on the implementation of the control software of the MST prototype are presented.

  20. Stress, κ manipulations, and aversive effects of ethanol in adolescent and adult male rats.

    PubMed

    Anderson, R I; Agoglia, A E; Morales, M; Varlinskaya, E I; Spear, L P

    2013-09-26

    Elevated ethanol use during adolescence, a potentially stressful developmental period, is accompanied by insensitivity to many aversive effects of ethanol relative to adults. Given evidence that supports a role for stress and the kappa opioid receptor (KOR) system in mediating aversive properties of ethanol and other drugs, the present study assessed the role of KOR antagonism by nor-binaltorphimine (nor-BNI) on ethanol-induced conditioned taste aversion (CTA) in stressed (exposed to repeated restraint) and non-stressed male rats (Experiment 1), with half of the rats pretreated with nor-BNI before stressor exposure. In Experiment 2, CTA induced by the kappa agonist U62,066 was also compared in stressed and non-stressed adolescents and adults. A highly palatable solution (chocolate Boost) was used as the conditioned stimulus (CS), thereby avoiding the need for water deprivation to motivate consumption of the CS during conditioning. No effects of stress on ethanol-induced CTA were found, with all doses eliciting aversions in adolescents and adults in both stress conditions. However, among stressed subjects, adults given nor-BNI before the repeated stressor displayed blunted ethanol aversion relative to adults given saline at that time. This effect of nor-BNI was not seen in adolescents, findings that support a differential role for the KOR involvement in ethanol CTA in stressed adolescents and adults. Results from Experiment 2 revealed that all doses of U62,066 elicited aversions in non-stressed animals of both ages that were attenuated in stressed animals, findings that support a modulatory role for stress in aversive effects of KOR activation. Collectively, these results suggest that although KOR sensitivity appears to be reduced in stressed subjects, this receptor system does not appear to contribute to age differences in ethanol-induced CTA under the present test circumstances. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  1. Information and Communications Technology (ICT) Infrastructure for the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Gianotti, F.; Tacchini, A.; Leto, G.; Martinetti, E.; Bruno, P.; Bellassai, G.; Conforti, V.; Gallozzi, S.; Mastropietro, M.; Tanci, C.; Malaguti, G.; Trifoglio, M.

    2016-08-01

    The Cherenkov Telescope Array (CTA) represents the next generation of ground-based observatories for very high energy gamma-ray astronomy. The CTA will consist of two arrays at two different sites, one in the northern and one in the southern hemisphere. The current CTA design foresees, in the southern site, the installation of many tens of imaging atmospheric Cherenkov telescopes of three different classes, namely large, medium and small, so defined in relation to their mirror area; the northern hemisphere array would consist of few tens of the two larger telescope types. The Italian National Institute for Astrophysics (INAF) is developing the Cherenkov Small Size Telescope ASTRI SST- 2M end-to-end prototype telescope within the framework of the International Cherenkov Telescope Array (CTA) project. The ASTRI prototype has been installed at the INAF observing station located in Serra La Nave on Mt. Etna, Italy. Furthermore a mini-array, composed of nine of ASTRI telescopes, has been proposed to be installed at the Southern CTA site. Among the several different infrastructures belonging the ASTRI project, the Information and Communication Technology (ICT) equipment is dedicated to operations of computing and data storage, as well as the control of the entire telescope, and it is designed to achieve the maximum efficiency for all performance requirements. Thus a complete and stand-alone computer centre has been designed and implemented. The goal is to obtain optimal ICT equipment, with an adequate level of redundancy, that might be scaled up for the ASTRI mini-array, taking into account the necessary control, monitor and alarm system requirements. In this contribution we present the ICT equipment currently installed at the Serra La Nave observing station where the ASTRI SST-2M prototype will be operated. The computer centre and the control room are described with particular emphasis on the Local Area Network scheme, the computing and data storage system, and the telescope control and monitoring.

  2. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    PubMed

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  3. ACR Appropriateness Criteria® Nonvariceal Upper Gastrointestinal Bleeding.

    PubMed

    Singh-Bhinder, Nimarta; Kim, David H; Holly, Brian P; Johnson, Pamela T; Hanley, Michael; Carucci, Laura R; Cash, Brooks D; Chandra, Ankur; Gage, Kenneth L; Lambert, Drew L; Levy, Angela D; Oliva, Isabel B; Peterson, Christine M; Strax, Richard; Rybicki, Frank J; Dill, Karin E

    2017-05-01

    Upper gastrointestinal bleeding (UGIB) remains a significant cause of morbidity and mortality with mortality rates as high as 14%. This document addresses the indications for imaging UGIB that is nonvariceal and unrelated to portal hypertension. The four variants are derived with respect to upper endoscopy. For the first three, it is presumed that upper endoscopy has been performed, with three potential initial outcomes: endoscopy reveals arterial bleeding source, endoscopy confirms UGIB without a clear source, and negative endoscopy. The fourth variant, "postsurgical and traumatic causes of UGIB; endoscopy contraindicated" is considered separately because upper endoscopy is not performed. When endoscopy identifies the presence and location of bleeding but bleeding cannot be controlled endoscopically, catheter-based arteriography with treatment is an appropriate next study. CT angiography (CTA) is comparable with angiography as a diagnostic next step. If endoscopy demonstrates a bleed but the endoscopist cannot identify the bleeding source, angiography or CTA can be typically performed and both are considered appropriate. In the event of an obscure UGIB, angiography and CTA have been shown to be equivalent in identifying the bleeding source; CT enterography may be an alternative to CTA to find an intermittent bleeding source. In the postoperative or traumatic setting when endoscopy is contraindicated, primary angiography, CTA, and CT with intravenous contrast are considered appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Thermo-responsive hydrogels for intravitreal injection and biomolecule release

    NASA Astrophysics Data System (ADS)

    Drapala, Pawel

    In this dissertation, we develop an injectable polymer system to enable localized and prolonged release of therapeutic biomolecules for improved treatment of Age-Related Macular Degeneration (AMD). Thermo-responsive hydrogels derived from N-isopropylacrylamide (NIPAAm) and cross-linked with poly(ethylene glycol) (PEG) poly(L-Lactic acid) (PLLA) copolymer were synthesized via free-radical polymerization. These materials were investigated for (a) phase change behavior, (b) in-vitro degradation, (c) capacity for controlled drug delivery, and (d) biocompatibility. The volume-phase transition temperature (VPTT) of the PNIPAAm- co-PEG-b-PLLA hydrogels was adjusted using hydrophilic and hydrophobic moieties so that it is ca. 33°C. These hydrogels did not initially show evidence of degradation at 37°C due to physical cross-links of collapsed PNIPAAm. Only after addition of glutathione chain transfer agents (CTA)s to the precursor did the collapsed hydrogels become fully soluble at 37°C. CTAs significantly affected the release kinetics of biomolecules; addition of 1.0 mg/mL glutathione to 3 mM cross-linker accelerated hydrogel degradation, resulting in 100% release in less than 2 days. This work also explored the effect of PEGylation in order to tether biomolecules to the polymer matrix. It was demonstrated that non-site-specific PEGylation can postpone the burst release of solutes (up to 10 days in hydrogels with 0.5 mg/mL glutathione). Cell viability assays showed that at least two 20-minute buffer extraction steps were needed to remove cytotoxic elements from the hydrogels. Clinically-used therapeutic biomolecules LucentisRTM and AvastinRTM were demonstrated to be both stable and bioactive after release form PNIPAAm-co-PEG-b-PLLA hydrogels. The thermo-responsive hydrogels presented here offer a promising platform for the localized delivery of proteins such as recombinant antibodies.

  5. Fermi LAT detection of a continuing increase of gamma-ray activity of CTA 102

    NASA Astrophysics Data System (ADS)

    Orienti, M.; D'Ammando, F.

    2012-09-01

    The Large Area Telescope (LAT), on board the Fermi Gamma-ray Space Telescope, has observed gamma-ray flaring activity from a source positionally consistent with the flat spectrum radio quasar CTA 102 (also known as 2FGL J2232.4+1143, Nolan et al. 2012, ApJS, 199, 31) with radio coordinates R.A.: 338.1517038 deg, Dec: 11.7308067 deg (J2000, Johnston et al. 1995, AJ, 110, 880) at redshift z=1.037 (Schmidt 1965, ApJ, 141, 1295).

  6. Multiband VLBI Observations of CTA102

    NASA Technical Reports Server (NTRS)

    Rantakyro, F. T.; Baath, L. B.; Dallacasa, D.; Jones, D. L.; Wehrle, A. E.

    1995-01-01

    The source CTA102, known to exhibit low frequency variability, has been observed at six epochs (three at lambda 32 cm, two at lambda 18 cm, and one at lambda l.3 cm) with intercontinental VLBI arrays. On the basis of the changes observed in the structure, we believe that the flux density variations at these wavelengths are due to intrinsic processes and not due to interstellar scintillation. This source exhibits behaviour suggestive of being expanding with a very high apparent transverse velocity.

  7. Mechanisms of Radiation-Induced Conditioned Taste Aversion Learning

    DTIC Science & Technology

    1986-01-01

    to Walter A. Hunt. 86 4 21 144 . J Jr -.W U *’ = 7 . 7 .: M: W. ,WLW;i , .-, -’ .’P. %k T .- - ’ .: ’W ; .a --,.-" -. t .:-. , 56 RABIN AND HUNT can...8217. 7m. U RADIATION-INDUCED TASTE AVERSIONS 57 induced CTA 11021. Alternatively, when the antihistamine is [ 21 . A radiation-induced CTA can be...in rats. Pharmmad psychioactive drugs. J (omp Phvsiod Pvchld .;’: 21 -26. 1972. Biochem Behav 17: 305-311. 1982. 4. Berger. B. D.. C. D. Wise and L

  8. Seeing Stars - Intensity Interferometry in the Laboratory & on the Ground

    NASA Astrophysics Data System (ADS)

    Carlile, Colin; Dravins, Dainis

    2018-04-01

    In many ways it is a golden age for astronomy. Spectacular new discoveries, for example the detection of gravitational waves, are very dependent upon instrumental development. The specific instrument development we propose, Intensity Interferometry (II), aims toimprove the spatial resolution of optical telescopes by 100x to 50µas [1]. This is impractical to achieve by increasing the size of telescopes or by extending the capabilities of phase interferometry. II, if implemented on the Cherenkov Telescope Array (CTA) currently being installed in La Palma and Paranal, would record the light intensity – the photon train - from many different telescopes, up to 2 km apart, on a nanosecond timescale and compare them. The signal from the many pairs of telescopes would quantify the degree of correlation by extracting the second-order correlation function, and thus create an image. This is not a real space image. However we can invert the data by Fourier Transform and create a real image. The more telescopes, the better resolved and more physical is the image, enabling the study of sunspots on nearby stars; orbiting binary stars; or exoplanets traversing the disc of their own star. We understand the Sun well but we have little experimental knowledge of how representative it is of main sequence stars. To test the II method, at Lund Observatory we have set up a laboratory analogue comprising ten small telescopes observing an artificial star created by light from a laser. The method has been shown to work [2] and the telescope array has now been extended to two dimensions. We are in discussion with other groups to explore the possibility of implementing this method on real telescopes observing actual stars. We plan to do this with the prototype Small Size Telescopes being built by groups in Europe, and ultimately with the CTA itself. A Science Working Group for II has now been set up within the CTA Consortium, of which Lund University is an integral part. A Letter of Intent has been sent to CTA expressing these intentions. An attractive aspect of II is its complementarity to the principle goal of CTA - the exploration of high energy cosmic rays via the Cherenkov light they generate in the atmosphere. This can only be observed under the most demanding atmospheric conditions whereas II can be recorded when conditions are poor: with a bright Moon, during periods of turbulence; in hazy conditions; or after dusk and before dawn. Two further advantages of implementing an II option on CTA are the minimal marginal costs incurred to an already 400M€ investment and, secondly, that even a few telescopes would produce unique scientific results even in the early days when the CTA array is far from complete. [1] Dainis Dravins and Colin Carlile, SPIE Newsroom (2016), http://spie.org/newsroom/6504-kilometer-baseline-optical-intensity-interferometry-for-stellar-surface-observations [2] D. Dravins, T. Lagadec, P.D. Nuñez, Nature Communications 6, 6852 (2015)

  9. The differential role of cortical protein synthesis in taste memory formation and persistence

    NASA Astrophysics Data System (ADS)

    Levitan, David; Gal-Ben-Ari, Shunit; Heise, Christopher; Rosenberg, Tali; Elkobi, Alina; Inberg, Sharon; Sala, Carlo; Rosenblum, Kobi

    2016-05-01

    The current dogma suggests that the formation of long-term memory (LTM) is dependent on protein synthesis but persistence of the memory trace is not. However, many of the studies examining the effect of protein synthesis inhibitors (PSIs) on LTM persistence were performed in the hippocampus, which is known to have a time-dependent role in memory storage, rather than the cortex, which is considered to be the main structure to store long-term memories. Here we studied the effect of PSIs on LTM formation and persistence in male Wistar Hola (n⩾5) rats by infusing the protein synthesis inhibitor, anisomycin (100 μg, 1 μl), into the gustatory cortex (GC) during LTM formation and persistence in conditioned taste aversion (CTA). We found that local anisomycin infusion to the GC before memory acquisition impaired LTM formation (P=8.9E-5), but had no effect on LTM persistence when infused 3 days post acquisition (P=0.94). However, when we extended the time interval between treatment with anisomycin and testing from 3 days to 14 days, LTM persistence was enhanced (P=0.01). The enhancement was on the background of stable and non-declining memory, and was not recapitulated by another amnesic agent, APV (10 μg, 1 μl), an N-methyl-D-aspartate receptor antagonist (P=0.54). In conclusion, CTA LTM remains sensitive to the action of PSIs in the GC even 3 days following memory acquisition. This sensitivity is differentially expressed between the formation and persistence of LTM, suggesting that increased cortical protein synthesis promotes LTM formation, whereas decreased protein synthesis promotes LTM persistence.

  10. Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography.

    PubMed

    Lee, E J; Lee, S K; Agid, R; Howard, P; Bae, J M; terBrugge, K

    2009-10-01

    The combined automatic tube current modulation (ATCM) technique adapts and modulates the x-ray tube current in the x-y-z axis according to the patient's individual anatomy. We compared image quality and radiation dose of the combined ATCM technique with those of a fixed tube current (FTC) technique in craniocervical CT angiography performed with a 64-section multidetector row CT (MDCT) system. A retrospective review of craniocervical CT angiograms (CTAs) by using combined ATCM (n = 25) and FTC techniques (n = 25) was performed. Other CTA parameters, such as kilovolt (peak), matrix size, FOV, section thickness, pitch, contrast agent, and contrast injection techniques, were held constant. We recorded objective image noise in the muscles at 2 anatomic levels: radiation exposure doses (CT dose index volume and dose-length product); and subjective image quality parameters, such as vascular delineation of various arterial vessels, visibility of small arterial detail, image artifacts, and certainty of diagnosis. The Mann-Whitney U test was used for statistical analysis. No significant difference was detected in subjective image quality parameters between the FTC and combined ATCM techniques. Most subjects in both study groups (49/50, 98%) had acceptable subjective artifacts. The objective image noise values at shoulder level did not show a significant difference, but the noise value at the upper neck was higher with the combined ATCM (P < .05) technique. Significant reduction in radiation dose (18% reduction) was noted with the combined ATCM technique (P < .05). The combined ATCM technique for craniocervical CTA performed at 64-section MDCT substantially reduced radiation exposure dose but maintained diagnostic image quality.

  11. Comparison Between Prospectively Electrocardiogram-Gated High-Pitch Mode and Retrospectively Electrocardiogram-Gated Mode for Dual-Source CT Coronary Angiography.

    PubMed

    Koplay, Mustafa; Celik, Mahmut; Avcı, Ahmet; Erdogan, Hasan; Demir, Kenan; Sivri, Mesut; Nayman, Alaaddin

    2015-01-01

    We aimed to report the image quality, relationship between heart rate and image quality, amount of contrast agent given to the patients and radiation doses in coronary CT angiography (CTA) obtained by using high-pitch prospectively ECG-gated "Flash Spiral" technique (method A) or retrospectively ECG-gated technique (method B) using 128×2-slice dual-source CT. A total of 110 patients who were evaluated with method A and method B technique with a 128×2-detector dual-source CT device were included in the study. Patients were divided into three groups based on their heart rates during the procedure, and a relationship between heart rate and image quality were evaluated. The relationship between heart rate, gender and radiation dose received by the patients was compared. A total of 1760 segments were evaluated in terms of image quality. Comparison of the relationship between heart rate and image quality revealed a significant difference between heart rate <60 beats/min group and >75 beats/min group whereas <60 beats/min and 60-75 beats/min groups did not differ significantly. The average effective dose for coronary CTA was calculated as 1.11 mSv (0.47-2.01 mSv) for method A and 8.22 mSv (2.19-12.88 mSv) for method B. Method A provided high quality images with doses as low as <1 mSv in selected patients who have low heart rates with a high negative predictive value to rule out coronary artery disease. Although method B increases the amount of effective dose, it provides high diagnostic quality images for patients who have a high heart rate and arrhythmia which makes it is difficult to obtain images.

  12. 76 FR 23631 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-27

    ... non-compliance with the Commission's minimum performance standards regarding registered transfer agents, and (2) to assure that issuers are aware of certain problems and poor performances with respect... notice of a registered transfer agent's failure to comply with the Commission's minimum performance...

  13. Gene transfer agents: phage-like elements of genetic exchange

    PubMed Central

    Lang, Andrew S.; Zhaxybayeva, Olga; Beatty, J. Thomas

    2013-01-01

    Horizontal gene transfer is important in the evolution of bacterial and archaeal genomes. An interesting genetic exchange process is carried out by diverse phage-like gene transfer agents (GTAs) that are found in a wide range of prokaryotes. Although GTAs resemble phages, they lack the hallmark capabilities that define typical phages, and they package random pieces of the producing cell’s genome. In this Review, we discuss the defining characteristics of the GTAs that have been identified to date, along with potential functions for these agents and the possible evolutionary forces that act on the genes involved in their production. PMID:22683880

  14. Argentinean outdoor test facility for mirrors

    NASA Astrophysics Data System (ADS)

    Medina, M. C.; Dipold, J.; García, B.; Mansilla, A.; Maya, J.; Rasztocky, E.; de Souza, V.; Larrarte, J. J.; Benitez, M.

    2015-08-01

    The Cherenkov Telescope Array (CTA) is planned to be an Observatory for very high energy -ray astronomy and will consist of several tens of telescopes which account for a reflective surface of more than 10000 m. These mirrors will be formed by a set of reflective facets. Different technological solutions, for a fast and cost efficient production of light-weight mirror facets are under test inside the CTA Consortium. Most of them involve composite structures whose behavior under real observing conditions is not yet fully tested. An outdoor test facility has been built in one of the former candidate sites for CTA, in Argentina (San Antonio de los Cobres [SAC], 3600 m a.s.l) in order to monitor the optical and mechanical properties of these facets exposed to the local atmospheric conditions for a given period of time. Four prototype mirrors built with different technologies have been installed and have been monitored for 6 months. In this work we present the preliminary results of this characterization.

  15. Contrast-enhanced magnetic resonance angiography for preoperative imaging of deep inferior epigastric artery perforator flaps: advantages and disadvantages compared with computed tomography angiography: a United Kingdom perspective.

    PubMed

    Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; McCulley, Stephen J

    2011-12-01

    The anatomy of the anterior abdominal wall is highly variable and leads to uncertainty when harvesting a deep inferior epigastric artery perforator flap. Presurgical imaging has been shown to reduce the operating time, as well as reduce the rates of flap and donor site complications. The importance of imaging of the venous system has also been recognized for reducing the risk of venous congestion. The modalities currently available for presurgical imaging include handheld Doppler ultrasound, duplex ultrasound, computed tomographic angiography (CTA), and contrast-enhanced magnetic resonance angiography (CE-MRA). Of these, the most promising are CTA and CE-MRA, and advantages and disadvantages exist for both modalities. In this article, we review the use of CE-MRA for preoperative flap imaging and report our experience with its use in deep inferior epigastric artery perforator flap harvest, as well as compare it with CTA. We also explore the future directions for presurgical flap imaging.

  16. STS-52 CANEX-2 Canadian Target Assembly (CTA) held by RMS over OV-102's PLB

    NASA Image and Video Library

    1992-11-01

    STS052-71-057 (22 Oct-1 Nov 1992) --- This 70mm frame, photographed with a handheld Hasselblad camera aimed through Columbia's aft flight deck windows, captures the operation of the Space Vision System (SVS) experiment above the cargo bay. Target dots have been placed on the Canadian Target Assembly (CTA), a small satellite, in the grasp of the Canadian-built remote manipulator system (RMS) arm. SVS utilized a Shuttle TV camera to monitor the dots strategically arranged on the satellite, to be tracked. As the satellite moved via the arm, the SVS computer measured the changing position of the dots and provided real-time television display of the location and orientation of the CTA. This type of displayed information is expected to help an operator guide the RMS or the Mobile Servicing System (MSS) of the future when berthing or deploying satellites. Also visible in the frame is the U.S. Microgravity Payload (USMP-01).

  17. Chromium (Ⅵ) removal from aqueous solutions through powdered activated carbon countercurrent two-stage adsorption.

    PubMed

    Wang, Wenqiang

    2018-01-01

    To exploit the adsorption capacity of commercial powdered activated carbon (PAC) and to improve the efficiency of Cr(VI) removal from aqueous solutions, the adsorption of Cr(VI) by commercial PAC and the countercurrent two-stage adsorption (CTA) process was investigated. Different adsorption kinetics models and isotherms were compared, and the pseudo-second-order model and the Langmuir and Freundlich models fit the experimental data well. The Cr(VI) removal efficiency was >80% and was improved by 37% through the CTA process compared with the conventional single-stage adsorption process when the initial Cr(VI) concentration was 50 mg/L with a PAC dose of 1.250 g/L and a pH of 3. A calculation method for calculating the effluent Cr(VI) concentration and the PAC dose was developed for the CTA process, and the validity of the method was confirmed by a deviation of <5%. Copyright © 2017. Published by Elsevier Ltd.

  18. Parabrachial gustatory lesions impair taste aversion learning in rats.

    PubMed

    Spector, A C; Norgren, R; Grill, H J

    1992-02-01

    Lesions in the gustatory zone of the parabrachial nuclei (PBN) severely impair acquisition of a conditioned taste aversion (CTA) in rats. To test whether this deficit has a memorial basis, intact rats (n = 15) and rats with PBN lesions (PBNX; n = 10) received seven intraoral taste stimulus infusions (30 s, 0.5 ml) distributed over a 30.5-min period after either LiCl or NaCl injection. This task measures the rapid formation of a CTA and has minimum demands on memory. LiCl-injected intact rats progressively changed their oromotor response profile from one of ingestion to one of aversion. NaCl-injected intact rats did not change their ingestive pattern of responding. In contrast, there was no difference between LiCl- and NaCl-injected PBNX rats. These same PBNX rats failed to avoid licking the taste stimulus when tested in a different paradigm. A simple impairment in a memorial process is not likely the basis for the CTA deficit.

  19. The Cherenkov Telescope Array: Exploring the Very-high-energy Sky from ESO's Paranal Site

    NASA Astrophysics Data System (ADS)

    Hofmann, W.

    2017-06-01

    The Cherenkov Telescope Array (CTA) is a next-generation observatory for ground-based very-high-energy gamma-ray astronomy, using the imaging atmospheric Cherenkov technique to detect and reconstruct gamma-ray induced air showers. The CTA project is planning to deploy 19 telescopes on its northern La Palma site, and 99 telescopes on its southern site at Paranal, covering the 20 GeV to 300 TeV energy domain and offering vastly improved performance compared to currently operating Cherenkov telescopes. The combination of three different telescope sizes (23-, 12- and 4-metre) allows cost-effective coverage of the wide energy range. CTA will be operated as a user facility, dividing observation time between a guest observer programme and large Key Science Projects (KSPs), and the data will be made public after a one-year proprietary period. The history of the project, the implementation of the arrays, and some of the major science goals and KSPs, are briefly summarised.

  20. Cholera Toxin B: One Subunit with Many Pharmaceutical Applications

    PubMed Central

    Baldauf, Keegan J.; Royal, Joshua M.; Hamorsky, Krystal Teasley; Matoba, Nobuyuki

    2015-01-01

    Cholera, a waterborne acute diarrheal disease caused by Vibrio cholerae, remains prevalent in underdeveloped countries and is a serious health threat to those living in unsanitary conditions. The major virulence factor is cholera toxin (CT), which consists of two subunits: the A subunit (CTA) and the B subunit (CTB). CTB is a 55 kD homopentameric, non-toxic protein binding to the GM1 ganglioside on mammalian cells with high affinity. Currently, recombinantly produced CTB is used as a component of an internationally licensed oral cholera vaccine, as the protein induces potent humoral immunity that can neutralize CT in the gut. Additionally, recent studies have revealed that CTB administration leads to the induction of anti-inflammatory mechanisms in vivo. This review will cover the potential of CTB as an immunomodulatory and anti-inflammatory agent. We will also summarize various recombinant expression systems available for recombinant CTB bioproduction. PMID:25802972

Top