Sample records for transfer coefficient htc

  1. Determination of heat transfer coefficient for an interaction of sub-cooled gas and metal

    NASA Astrophysics Data System (ADS)

    Zaidi Sidek, Mohd; Syahidan Kamarudin, Muhammad

    2016-02-01

    Heat transfer coefficient (HTC) for a hot metal surface and their surrounding is one of the need be defined parameter in hot forming process. This study has been conducted to determine the HTC for an interaction between sub-cooled gas sprayed on a hot metal surface. Both experiments and finite element have been adopted in this work. Initially, the designated experiment was conducted to obtain temperature history of spray cooling process. Then, an inverse method was adopted to calculate the HTC value before we validate in a finite element simulation model. The result shows that the heat transfer coefficient for interaction of subcooled gas and hot metal surface is 1000 W/m2K.

  2. Calculation and validation of heat transfer coefficient for warm forming operations

    NASA Astrophysics Data System (ADS)

    Omer, Kaab; Butcher, Clifford; Worswick, Michael

    2017-10-01

    In an effort to reduce the weight of their products, the automotive industry is exploring various hot forming and warm forming technologies. One critical aspect in these technologies is understanding and quantifying the heat transfer between the blank and the tooling. The purpose of the current study is twofold. First, an experimental procedure to obtain the heat transfer coefficient (HTC) as a function of pressure for the purposes of a metal forming simulation is devised. The experimental approach was used in conjunction with finite element models to obtain HTC values as a function of die pressure. The materials that were characterized were AA5182-O and AA7075-T6. Both the heating operation and warm forming deep draw were modelled using the LS-DYNA commercial finite element code. Temperature-time measurements were obtained from both applications. The results of the finite element model showed that the experimentally derived HTC values were able to predict the temperature-time history to within a 2% of the measured response. It is intended that the HTC values presented herein can be used in warm forming models in order to accurately capture the heat transfer characteristics of the operation.

  3. Correlation of heat transfer coefficient in quenching process using ABAQUS

    NASA Astrophysics Data System (ADS)

    Davare, Sandeep Kedarnath; Balachandran, G.; Singh, R. K. P.

    2018-04-01

    During the heat treatment by quenching in a liquid medium the convective heat transfer coefficient plays a crucial role in the extraction of heat. The heat extraction ultimately influences the cooling rate and hence the hardness and mechanical properties. A Finite Element analysis of quenching a simple flat copper sample with different orientation of sample and with different quenchant temperatures were carried out to check and verify the results obtained from the experiments. The heat transfer coefficient (HTC) was calculated from temperature history in a simple flat copper disc sample experimentally. This HTC data was further used as input to simulation software and the cooling curves were back calculated. The results obtained from software and using experimentation shows nearly consistent values.

  4. Measurement of heat transfer coefficient using termoanemometry methods

    NASA Astrophysics Data System (ADS)

    Dančová, P.; Sitek, P.; Vít, T.

    2014-03-01

    This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC) is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  5. Near-field radiative heat transfer between graphene-covered hyperbolic metamaterials

    NASA Astrophysics Data System (ADS)

    Hong, Xiao-Juan; Li, Jian-Wen; Wang, Tong-Biao; Zhang, De-Jian; Liu, Wen-Xing; Liao, Qing-Hua; Yu, Tian-Bao; Liu, Nian-Hua

    2018-04-01

    We propose the use of graphene-covered silicon carbide (SiC) nanowire arrays (NWAs) for theoretical studies of near-field radiative heat transfer. The SiC NWAs exhibit a hyperbolic characteristic at an appropriately selected filling-volume fraction. The surface plasmon supported by graphene and the hyperbolic modes supported by SiC NWAs significantly affect radiative heat transfer. The heat-transfer coefficient (HTC) between the proposed structures is larger than that between SiC NWAs. We also find that the chemical potential of graphene plays an important role in modulating the HTC. The tunability of chemical potential through gate voltage enables flexible control of heat transfer using the graphene-covered SiC NWAs.

  6. Experimental investigation of time and repeated cycles in nucleate pool boiling of alumina/water nanofluid on polished and machined surfaces

    NASA Astrophysics Data System (ADS)

    Rajabzadeh Dareh, F.; Haghshenasfard, M.; Nasr Esfahany, M.; Salimi Jazi, H.

    2018-06-01

    Pool boiling heat transfer of pure water and nanofluids on a copper block has been studied experimentally. Nanofluids with various concentrations of 0.0025, 0.005 and 0.01 vol.% are employed and two simple surfaces (polished and machined copper surface) are used as the heating surfaces. The results indicated that the critical heat flux (CHF) in boiling of fluids on the polished surface is 7% higher than CHF on the machined surface. In the case of machined surface, the heat transfer coefficient (HTC) of 0.01 vol.% nanofluid is about 37% higher than HTC of base fluid, while in the polished surface the average HTC of 0.01% nanofluid is about 19% lower than HTC of the pure water. The results also showed that the boiling time and boiling cycles on the polished surface changes the heat transfer performance. By increasing the boiling time from 5 to 10 min, the roughness enhances about 150%, but by increasing the boiling time to 15 min, the roughness enhancement is only 8%.

  7. Reliable prediction of heat transfer coefficient in three-phase bubble column reactor via adaptive neuro-fuzzy inference system and regularization network

    NASA Astrophysics Data System (ADS)

    Garmroodi Asil, A.; Nakhaei Pour, A.; Mirzaei, Sh.

    2018-04-01

    In the present article, generalization performances of regularization network (RN) and optimize adaptive neuro-fuzzy inference system (ANFIS) are compared with a conventional software for prediction of heat transfer coefficient (HTC) as a function of superficial gas velocity (5-25 cm/s) and solid fraction (0-40 wt%) at different axial and radial locations. The networks were trained by resorting several sets of experimental data collected from a specific system of air/hydrocarbon liquid phase/silica particle in a slurry bubble column reactor (SBCR). A special convection HTC measurement probe was manufactured and positioned in an axial distance of 40 and 130 cm above the sparger at center and near the wall of SBCR. The simulation results show that both in-house RN and optimized ANFIS due to powerful noise filtering capabilities provide superior performances compared to the conventional software of MATLAB ANFIS and ANN toolbox. For the case of 40 and 130 cm axial distance from center of sparger, at constant superficial gas velocity of 25 cm/s, adding 40 wt% silica particles to liquid phase leads to about 66% and 69% increasing in HTC respectively. The HTC in the column center for all the cases studied are about 9-14% larger than those near the wall region.

  8. Pool-Boiling Heat-Transfer Enhancement on Cylindrical Surfaces with Hybrid Wettable Patterns.

    PubMed

    Kumar C S, Sujith; Chang, Yao Wen; Chen, Ping-Hei

    2017-04-10

    In this study, pool-boiling heat-transfer experiments were performed to investigate the effect of the number of interlines and the orientation of the hybrid wettable pattern. Hybrid wettable patterns were produced by coating superhydrophilic SiO2 on a masked, hydrophobic, cylindrical copper surface. Using de-ionized (DI) water as the working fluid, pool-boiling heat-transfer studies were conducted on the different surface-treated copper cylinders of a 25-mm diameter and a 40-mm length. The experimental results showed that the number of interlines and the orientation of the hybrid wettable pattern influenced the wall superheat and the HTC. By increasing the number of interlines, the HTC was enhanced when compared to the plain surface. Images obtained from the charge-coupled device (CCD) camera indicated that more bubbles formed on the interlines as compared to other parts. The hybrid wettable pattern with the lowermost section being hydrophobic gave the best heat-transfer coefficient (HTC). The experimental results indicated that the bubble dynamics of the surface is an important factor that determines the nucleate boiling.

  9. Nano-inspired fluidic interactivity for boiling heat transfer: impact and criteria

    PubMed Central

    Kim, Beom Seok; Choi, Geehong; Shin, Sangwoo; Gemming, Thomas; Cho, Hyung Hee

    2016-01-01

    The enhancement of boiling heat transfer, the most powerful energy-transferring technology, will lead to milestones in the development of high-efficiency, next-generation energy systems. Perceiving nano-inspired interface functionalities from their rough morphologies, we demonstrate interface-induced liquid refreshing is essential to improve heat transfer by intrinsically avoiding Leidenfrost phenomenon. High liquid accessibility of hemi-wicking and catalytic nucleation, triggered by the morphological and hydrodynamic peculiarities of nano-inspired interfaces, contribute to the critical heat flux (CHF) and the heat transfer coefficient (HTC). Our experiments show CHF is a function of universal hydrodynamic characteristics involving interfacial liquid accessibility and HTC is improved with a higher probability of smaller nuclei with less superheat. Considering the interface-induced and bulk liquid accessibility at boiling, we discuss functionalizing the interactivity between an interface and a counteracting fluid seeking to create a novel interface, a so-called smart interface, for a breakthrough in boiling and its pragmatic application in energy systems. PMID:27708341

  10. Rigorous theory of graded thermoelectric converters including finite heat transfer coefficients

    NASA Astrophysics Data System (ADS)

    Gerstenmaier, York Christian; Wachutka, Gerhard

    2017-11-01

    Maximization of thermoelectric (TE) converter performance with an inhomogeneous material and electric current distribution has been investigated in previous literature neglecting thermal contact resistances to the heat reservoirs. The heat transfer coefficients (HTCs), defined as inverse thermal contact resistances per unit area, are thus infinite, whereas in reality, always parasitic thermal resistances, i.e., finite HTCs, are present. Maximization of the generated electric power and of cooling power in the refrigerator mode with respect to Seebeck coefficients and heat conductivity for a given profile of the material's TE figure of merit Z are mathematically ill-posed problems in the presence of infinite HTCs. As will be shown in this work, a fully self consistent solution is possible for finite HTCs, and in many respects, the results are fundamentally different. A previous theory for 3D devices will be extended to include finite HTCs and is applied to 1D devices. For the heat conductivity profile, an infinite number of solutions exist leading to the same device performance. Cooling power maximization for finite HTCs in 1D will lead to a strongly enhanced corresponding efficiency (coefficient of performance), whereas results with infinite HTCs lead to a non-monotonous temperature profile and coefficient of performance tending to zero for the prescribed heat conductivities. For maximized generated electric power, the corresponding generator efficiency is nearly a constant independent from the finite HTC values. The maximized efficiencies in the generator and cooling mode are equal to the efficiencies for the infinite HTC, provided that the corresponding powers approach zero. These and more findings are condensed in 4 theorems in the conclusions.

  11. Experimental und numerical investigations on cooling efficiency of Air-Mist nozzles on steel during continuous casting

    NASA Astrophysics Data System (ADS)

    Arth, G.; Taferner, M.; Bernhard, C.; Michelic, S.

    2016-07-01

    Cooling strategies in continuous casting of steel can vary from rapid cooling to slow cooling, mainly controlled by adjusting the amount of water sprayed onto the surface of the product. Inadequate adjustment however can lead to local surface undercooling or reheating, leading to surface and inner defects. This paper focuses on cooling efficiency of Air-Mist nozzles on casted steel and the experimental and numerical prediction of surface temperature distributions over the product width. The first part explains the determination of heat transfer coefficients (HTC) on laboratory scale, using a so called nozzle measuring stand (NMS). Based on measured water distributions and determined HTC's for air-mist nozzles using the NMS, surface temperatures are calculated by a transient 2D-model on a simple steel plate, explained in the second part of this paper. Simulations are carried out varying water impact density and spray water distribution, consequently influencing the local HTC distribution over the plate width. Furthermore, these results will be interpreted with regard to their consequence for surface and internal quality of the cast product. The results reveal the difficulty of correct adjustment of the amount of sprayed water, concurrent influencing water distribution and thus changing HTC distribution and surface temperature.

  12. Critical Current Test of Liquid Hydrogen Cooled HTC Superconductors under External Magnetic Field

    NASA Astrophysics Data System (ADS)

    Shirai, Yasuyuki; Shiotsu, Masahiro; Tatsumoto, Hideki; Kobayashi, Hiroaki; Naruo, Yoshihiro; Nonaka, Satoshi; Inatani, Yoshifumi

    High-Tc (HTC) superconductors including MgB2 will show excellent properties under temperature of Liquid Hydrogen (LH2:20K), which has large latent heat and low viscosity coefficient. In order to design and fabricate the LH2 cooled superconducting energy devices, we must clear the cooling property of LH2 for superconductors, the cooling system and safety design of LH2 cooled superconducting devices and electro-magnetic property evaluation of superconductors (BSCCO, REBCO and MgB2) and their magnets cooled by LH2. As the first step of the study, an experimental setup which can be used for investigating heat transfer characteristics of LH2 in a pool and also in forced flow (circulation loop with a pump), and also for evaluation of electro-magnetic properties of LH2 cooled superconductors under external magnetic field (up to 7 T). In this paper, we will show a short sketch of the experimental set-up, practical experiences in safety operation of liquid hydrogen cooling system and example test results of critical current evaluation of HTC superconductors cooled by LH2.

  13. Condensation heat transfer correlation for water-ethanol vapor mixture flowing through a plate heat exchanger

    NASA Astrophysics Data System (ADS)

    Zhou, Weiqing; Hu, Shenhua; Ma, Xiangrong; Zhou, Feng

    2018-04-01

    Condensation heat transfer coefficient (HTC) as a function of outlet vapor quality was investigated using water-ethanol vapor mixture of different ethanol vapor concentrations (0%, 1%, 2%, 5%, 10%, 20%) under three different system pressures (31 kPa, 47 kPa, 83 kPa). A heat transfer coefficient was developed by applying multiple linear regression method to experimental data, taking into account the dimensionless numbers which represents the Marangoni condensation effects, such as Re, Pr, Ja, Ma and Sh. The developed correlation can predict the condensation performance within a deviation range from -22% to 32%. Taking PHE's characteristic into consideration and bringing in Ma number and Sh number, a new correlation was developed, which showed a much more accurate prediction, within a deviation from -3.2% to 7.9%.

  14. Independent and collective roles of surface structures at different length scales on pool boiling heat transfer

    PubMed Central

    Li, Calvin H.; Rioux, Russell P.

    2016-01-01

    Spherical Cu nanocavity surfaces are synthesized to examine the individual role of contact angles in connecting lateral Rayleigh-Taylor wavelength to vertical Kevin-Helmholtz wavelength on hydrodynamic instability for the onset of pool boiling Critical Heat Flux (CHF). Solid and porous Cu pillar surfaces are sintered to investigate the individual role of pillar structure pitch at millimeter scale, named as module wavelength, on hydrodynamic instability at CHF. Last, spherical Cu nanocavities are coated on the porous Cu pillars to create a multiscale Cu structure, which is studied to examine the collective role and relative significance of contact angles and module wavelength on hydrodynamic instability at CHF, and the results indicate that module wavelength plays the dominant role on hydrodynamic instability at CHF when the height of surface structures is equal or above ¼ Kelvin-Helmholtz wavelength. Pool boiling Heat Transfer Coefficient (HTC) enhancements on spherical Cu nanocavity surfaces, solid and porous Cu pillar surfaces, and the integrated multiscale structure have been investigated, too. The experimental results reveal that the nanostructures and porous pillar structures can be combined together to achieve even higher enhancement of HTC than that of individual structures. PMID:27841322

  15. 8. Innovative Technologies: Two-Phase Heat Transfer in Water-Based Nanofluids for Nuclear Applications Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buongiorno, Jacopo; Hu, Lin-wen

    2009-07-31

    Nanofluids are colloidal dispersions of nanoparticles in water. Many studies have reported very significant enhancement (up to 200%) of the Critical Heat Flux (CHF) in pool boiling of nanofluids (You et al. 2003, Vassallo et al. 2004, Bang and Chang 2005, Kim et al. 2006, Kim et al. 2007). These observations have generated considerable interest in nanofluids as potential coolants for more compact and efficient thermal management systems. Potential Light Water Reactor applications include the primary coolant, safety systems and severe accident management strategies, as reported in other papers (Buongiorno et al. 2008 and 2009). However, the situation of interestmore » in reactor applications is often flow boiling, for which no nanofluid data have been reported so far. In this project we investigated the potential of nanofluids to enhance CHF in flow boiling. Subcooled flow boiling heat transfer and CHF experiments were performed with low concentrations of alumina, zinc oxide, and diamond nanoparticles in water (≤ 0.1 % by volume) at atmospheric pressure. It was found that for comparable test conditions the values of the nanofluid and water heat transfer coefficient (HTC) are similar (within ±20%). The HTC increased with mass flux and heat flux for water and nanofluids alike, as expected in flow boiling. The CHF tests were conducted at 0.1 MPa and at three different mass fluxes (1500, 2000, 2500 kg/m2s) under subcooled conditions. The maximum CHF enhancement was 53%, 53% and 38% for alumina, zinc oxide and diamond, respectively, always obtained at the highest mass flux. A post-mortem analysis of the boiling surface reveals that its morphology is altered by deposition of the particles during nanofluids boiling. A confocal-microscopy-based examination of the test section revealed that nanoparticles deposition not only changes the number of micro-cavities on the surface, but also the surface wettability. A simple model was used to estimate the ensuing nucleation site density changes, but no definitive correlation between the nucleation site density and the heat transfer coefficient data could be found. Wettability of the surface was substantially increased for heater coupons boiled in alumina and zinc oxide nanofluids, and such wettability increase seems to correlate reasonably well with the observed marked CHF enhancement for the respective nanofluids. Interpretation of the experimental data was conducted in light of the governing surface parameters (surface area, contact angle, roughness, thermal conductivity) and existing models. It was found that no single parameter could explain the observed HTC or CHF phenomena.« less

  16. Experimental study on heat transfer to supercritical water flowing through tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, M.; Gu, H.; Cheng, X.

    2012-07-01

    A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2})more » and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)« less

  17. Bubble induced flow field modulation for pool boiling enhancement over a tubular surface

    NASA Astrophysics Data System (ADS)

    Raghupathi, P. A.; Joshi, I. M.; Jaikumar, A.; Emery, T. S.; Kandlikar, S. G.

    2017-06-01

    We demonstrate the efficacy of using a strategically placed enhancement feature to modify the trajectory of bubbles nucleating on a horizontal tubular surface to increase both the critical heat flux (CHF) and the heat transfer coefficient (HTC). The CHF on a plain tube is shown to be triggered by a local dryout at the bottom of the tube due to vapor agglomeration. To mitigate this effect and delay CHF, the nucleating bubble trajectory is modified by incorporating a bubble diverter placed axially at the bottom of the tube. The nucleating bubble at the base of the diverter experiences a tangential evaporation momentum force (EMF) which causes the bubble to grow sideways away from the tube and avoid localized bubble patches that are responsible for CHF initiation. High speed imaging confirmed the lateral displacement of the bubbles away from the diverter closely matched with the theoretical predictions using EMF and buoyancy forces. Since the EMF is stronger at higher heat fluxes, bubble displacement increases with heat flux and results in the formation of separate liquid-vapor pathways wherein the liquid enters almost unobstructed at the bottom and the vapor bubble leaves sideways. Experimental results yielded CHF and HTC enhancements of ˜60% and ˜75%, respectively, with the diverter configuration when compared to a plain tube. This work can be used for guidance in developing enhancement strategies to effectively modulate the liquid-vapor flow around the heater surface at various locations to enhance HTC and CHF.

  18. The experimental study of heat transfer around molds inside a model autoclave

    NASA Astrophysics Data System (ADS)

    Ghamlouch, Taleb; Roux, Stéphane; Lefèvre, Nicolas; Bailleul, Jean-Luc; Sobotka, Vincent

    2018-05-01

    The temperature distribution within composite parts manufactured inside autoclaves plays a key role in determining the parts quality at the end of the curing cycle. Indeed, heat transfer between the parts and the surroundings inside an autoclave is strongly coupled with the flow field around the molds and can be modeled through the convective heat transfer coefficient (HTC). The aerodynamically unsuitable geometry of the molds generates complex turbulent non-uniform flows around them accompanied with the presence of dead zones. This heterogeneity can imply non-uniform convective heat transfers leading to temperature gradients inside parts that can be prejudicial. Given this fact, the purpose of this study is to perform experimental measurements in order to describe the flow field and the convective heat transfer behavior around representative industrial molds installed inside a home-made model. A key point of our model autoclave is the ease of use of non-intrusive measuring instruments: the Particle Image Velocimetry (PIV) technique and infrared imaging camera for the study of the flow field and the heat transfer coefficient distribution around the molds respectively. The experimental measurements are then compared to computational fluid dynamics (CFD) calculations performed on the computer code ANSYS Fluent 16.0®. This investigation has revealed, as expected, a non-uniform distribution of the convective heat transfer coefficient around the molds and therefore the presence of thermal gradients which can reduce the composite parts quality during an autoclave process. A good agreement has been achieved between the experimental and the numerical results leading then to the validation of the performed numerical simulations.

  19. Experimental research and numerical simulation on cryogenic line chill-down process

    NASA Astrophysics Data System (ADS)

    Jin, Lingxue; Cho, Hyokjin; Lee, Cheonkyu; Jeong, Sangkwon

    2018-01-01

    The empirical heat transfer correlations are suggested for the fast cool down process of the cryogenic transfer line from room temperature to cryogenic temperature. The correlations include the heat transfer coefficient (HTC) correlations for single-phase gas convection and film boiling regimes, minimum heat flux (MHF) temperature, critical heat flux (CHF) temperature and CHF. The correlations are obtained from the experimental measurements. The experiments are conducted on a 12.7 mm outer diameter (OD), 1.25 mm wall thickness and 7 m long stainless steel horizontal pipe with liquid nitrogen (LN2). The effect of the lengthwise position is verified by measuring the temperature profiles in near the inlet and the outlet of the transfer line. The newly suggested heat transfer correlations are applied to the one-dimensional homogeneous transient model to simulate the cryogenic line chill-down process, and the chill-down time and the cryogen consumption are well predicted in the mass flux range from 26.0 kg/m2 s to 73.6 kg/m2 s through the correlations.

  20. Effect of Wind Flow on Convective Heat Losses from Scheffler Solar Concentrator Receivers

    NASA Astrophysics Data System (ADS)

    Nene, Anita Arvind; Ramachandran, S.; Suyambazhahan, S.

    2018-05-01

    Receiver is an important element of solar concentrator system. In a Scheffler concentrator, solar rays get concentrated at focus of parabolic dish. While radiation losses are more predictable and calculable since strongly related to receiver temperature, convective looses are difficult to estimate in view of additional factors such as wind flow direction, speed, receiver geometry, prior to current work. Experimental investigation was carried out on two geometries of receiver namely cylindrical and conical with 2.7 m2 Scheffler to find optimum condition of tilt to provide best efficiency. Experimental results showed that as compared to cylindrical receiver, conical receiver gave maximum efficiency at 45° tilt angle. However effect of additional factors like wind speed, wind direction on especially convective losses could not be separately seen. The current work was undertaken to investigate further the same two geometries using computation fluid dynamics using FLUENT to compute convective losses considering all variables such at tilt angle of receiver, wind velocity and wind direction. For cylindrical receiver, directional heat transfer coefficient (HTC) is remarkably high to tilt condition meaning this geometry is critical to tilt leading to higher convective heat losses. For conical receiver, directional average HTC is remarkably less to tilt condition leading to lower convective heat loss.

  1. Breakdown of the Coulomb friction law in TiC/a-C:H nanocomposite coatings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pei, Y. T.; Huizenga, P.; Galvan, D.

    2006-12-01

    Advanced TiC/a-C:H nanocomposite coatings have been produced via reactive deposition in a closed-field unbalanced magnetron sputtering system (Hauzer HTC-1000 or HTC 1200). In this paper, we report on the tribological behavior of TiC/a-C:H nanocomposite coatings in which ultralow friction is tailored with superior wear resistance, two properties often difficult to achieve simultaneously. Tribotests have been performed at room temperature with a ball-on-disk configuration. In situ monitoring of the wear depth of the coated disk together with the wear height of the ball counterpart at nanometer scale reveals that the self-lubricating effects are induced by the formation of transfer films onmore » the surface of the ball counterpart. A remarkable finding is a breakdown of the Coulomb friction law in the TiC/a-C:H nanocomposite coatings. In addition, the coefficient of friction of TiC/a-C:H nanocomposite coatings decreases with decreasing relative humidity. A superior wear resistance of the coated disk at a level of 10{sup -17} m{sup 3}/N m (per lap) has been achieved under the condition of superlow friction and high toughness, both of which require fine TiC nanoparticles (e.g., 2 nm) and a wide matrix separation that must be comparable to the dimensions of the nanoparticles.« less

  2. Risk factors for service use and trends in coverage of different HIV testing and counselling models in northwest Tanzania between 2003 and 2010.

    PubMed

    Cawley, Caoimhe; Wringe, Alison; Todd, Jim; Gourlay, Annabelle; Clark, Benjamin; Masesa, Clemens; Machemba, Richard; Reniers, Georges; Urassa, Mark; Zaba, Basia

    2015-11-01

    To investigate the relative effectiveness of different HIV testing and counselling (HTC) services in improving HIV diagnosis rates and increasing HTC coverage in African settings. Patient records from three HTC services [community outreach HTC during cohort study rounds (CO-HTC), walk-in HTC at the local health centre (WI-HTC) and antenatal HIV testing (ANC-HTC)] were linked to records from a community cohort study using a probabilistic record linkage algorithm. Characteristics of linked users of each HTC service were compared to those of cohort participants who did not use the HTC service using logistic regression. Data from three cohort study rounds between 2003 and 2010 were used to assess trends in the proportion of persons testing at different service types. The adjusted odds ratios for HTC use among men with increasing numbers of sexual partners in the past year, and among HIV-positive men and women compared to HIV-negative men and women, were higher at WI-HTC than at CO-HTC and ANC-HTC. Among sero-survey participants, the largest numbers of HIV-positive men and women learned their status via CO-HTC. However, we are likely to have underestimated the numbers diagnosed at WI-HTC and ANC-HTC, due to low sensitivity of the probabilistic record linkage algorithm. Compared to CO-HTC or ANC-HTC, WI-HTC was most likely to attract HIV-positive men and women, and to attract men with greater numbers of sexual partners. Further research should aim to optimise probabilistic record linkage techniques, and to investigate which types of HTC services most effectively link HIV-positive people to treatment services relative to the total cost per diagnosis made. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  3. An automatic eye detection and tracking technique for stereo video sequences

    NASA Astrophysics Data System (ADS)

    Paduru, Anirudh; Charalampidis, Dimitrios; Fouts, Brandon; Jovanovich, Kim

    2009-05-01

    Human-computer interfacing (HCI) describes a system or process with which two information processors, namely a human and a computer, attempt to exchange information. Computer-to-human (CtH) information transfer has been relatively effective through visual displays and sound devices. On the other hand, the human-tocomputer (HtC) interfacing avenue has yet to reach its full potential. For instance, the most common HtC communication means are the keyboard and mouse, which are already becoming a bottleneck in the effective transfer of information. The solution to the problem is the development of algorithms that allow the computer to understand human intentions based on their facial expressions, head motion patterns, and speech. In this work, we are investigating the feasibility of a stereo system to effectively determine the head position, including the head rotation angles, based on the detection of eye pupils.

  4. Home-based versus mobile clinic HIV testing and counseling in rural Lesotho: a cluster-randomized trial.

    PubMed

    Labhardt, Niklaus Daniel; Motlomelo, Masetsibi; Cerutti, Bernard; Pfeiffer, Karolin; Kamele, Mashaete; Hobbins, Michael A; Ehmer, Jochen

    2014-12-01

    The success of HIV programs relies on widely accessible HIV testing and counseling (HTC) services at health facilities as well as in the community. Home-based HTC (HB-HTC) is a popular community-based approach to reach persons who do not test at health facilities. Data comparing HB-HTC to other community-based HTC approaches are very limited. This trial compares HB-HTC to mobile clinic HTC (MC-HTC). The trial was powered to test the hypothesis of higher HTC uptake in HB-HTC campaigns than in MC-HTC campaigns. Twelve clusters were randomly allocated to HB-HTC or MC-HTC. The six clusters in the HB-HTC group received 30 1-d multi-disease campaigns (five villages per cluster) that delivered services by going door-to-door, whereas the six clusters in MC-HTC group received campaigns involving community gatherings in the 30 villages with subsequent service provision in mobile clinics. Time allocation and human resources were standardized and equal in both groups. All individuals accessing the campaigns with unknown HIV status or whose last HIV test was >12 wk ago and was negative were eligible. All outcomes were assessed at the individual level. Statistical analysis used multivariable logistic regression. Odds ratios and p-values were adjusted for gender, age, and cluster effect. Out of 3,197 participants from the 12 clusters, 2,563 (80.2%) were eligible (HB-HTC: 1,171; MC-HTC: 1,392). The results for the primary outcomes were as follows. Overall HTC uptake was higher in the HB-HTC group than in the MC-HTC group (92.5% versus 86.7%; adjusted odds ratio [aOR]: 2.06; 95% CI: 1.18-3.60; p = 0. 011). Among adolescents and adults ≥ 12 y, HTC uptake did not differ significantly between the two groups; however, in children <12 y, HTC uptake was higher in the HB-HTC arm (87.5% versus 58.7%; aOR: 4.91; 95% CI: 2.41-10.0; p<0.001). Out of those who took up HTC, 114 (4.9%) tested HIV-positive, 39 (3.6%) in the HB-HTC arm and 75 (6.2%) in the MC-HTC arm (aOR: 0.64; 95% CI: 0.48-0.86; p = 0.002). Ten (25.6%) and 19 (25.3%) individuals in the HB-HTC and in the MC-HTC arms, respectively, linked to HIV care within 1 mo after testing positive. Findings for secondary outcomes were as follows: HB-HTC reached more first-time testers, particularly among adolescents and young adults, and had a higher proportion of men among participants. However, after adjusting for clustering, the difference in male participation was not significant anymore. Age distribution among participants and immunological and clinical stages among persons newly diagnosed HIV-positive did not differ significantly between the two groups. Major study limitations included the campaigns' restriction to weekdays and a relatively low HIV prevalence among participants, the latter indicating that both arms may have reached an underexposed population. This study demonstrates that both HB-HTC and MC-HTC can achieve high uptake of HTC. The choice between these two community-based strategies will depend on the objective of the activity: HB-HTC was better in reaching children, individuals who had never tested before, and men, while MC-HTC detected more new HIV infections. The low rate of linkage to care after a positive HIV test warrants future consideration of combining community-based HTC approaches with strategies to improve linkage to care for persons who test HIV-positive. ClinicalTrials.gov NCT01459120. Please see later in the article for the Editors' Summary.

  5. Sensitivity Analysis of Fuel Centerline Temperatures in SuperCritical Water-cooled Reactors (SCWRs)

    NASA Astrophysics Data System (ADS)

    Abdalla, Ayman

    SuperCritical Water-cooled Reactors (SCWRs) are one of the six nuclear-reactor concepts currently being developed under the Generation-IV International Forum (GIF). A main advantage of SCW Nuclear Power Plants (NPPs) is that they offer higher thermal efficiencies compared to those of current conventional NPPs. Unlike today's conventional NPPs, which have thermal efficiencies between 30 - 35%, SCW NPPs will have thermal efficiencies within a range of 45 - 50%, owing to high operating temperatures and pressures (i.e., coolant temperatures as high as 625°C at 25 MPa pressure). The use of current fuel bundles with UO2 fuel at the high operating parameters of SCWRs may cause high fuel centerline temperatures, which could lead to fuel failure and fission gas release. Studies have shown that when the Variant-20 (43-element) fuel bundle was examined at SCW conditions, the fuel centerline temperature industry limit of 1850°C for UO2 and the sheath temperature design limit of 850°C might be exceeded. Therefore, new fuel-bundle designs, which comply with the design requirements, are required for future use in SCWRs. The main objective of this study to conduct a sensitivity analysis in order to identify the main factors that leads to fuel centerline temperature reduction. Therefore, a 54-element fuel bundle with smaller diameter of fuel elements compared to that of the 43-element bundle was designed and various nuclear fuels are examined for future use in a generic Pressure Tube (PT) SCWR. The 54-element bundle consists of 53 heated fuel elements with an outer diameter of 9.5 mm and one central unheated element of 20-mm outer diameter which contains burnable poison. The 54-element fuel bundle has an outer diameter of 103.45 mm, which is the same as the outer diameter of the 43-element fuel bundle. After developing the 54-element fuel bundle, one-dimensional heat-transfer analysis was conducted using MATLAB and NIST REFPROP programs. As a result, the Heat Transfer Coefficient (HTC), bulk-fluid, sheath and fuel centerline temperature profiles were generated along the heated length of 5.772 m for a generic fuel channel. The fuel centerline and sheath temperature profiles have been determined at four Axial Heat Flux Profiles (AHFPs) using an average thermal power per channel of 8.5 MWth. The four examined AHFPs are the uniform, cosine, upstream-skewed and downstream-skewed profiles. Additionally, this study focuses on investigating a possibility of using low, enhanced and high thermal-conductivity fuels. The low thermal-conductivity fuels, which have been examined in this study, are uranium dioxide (UO 2), Mixed Oxide (MOX) and Thoria (ThO2) fuels. The examined enhanced thermal-conductivity fuels are uranium dioxide - silicon carbide (UO2 - SiC) and uranium dioxide - beryllium oxide (UO2 - BeO). Lastly, uranium carbide (UC), uranium dicarbide (UC2) and uranium nitride (UN) are the selected high thermal-conductivity fuels, which have been proposed for use in SCWRs. A comparison has been made between the low, enhanced and high thermal-conductivity fuels in order to identify the fuel centerline temperature behaviour when different nuclear fuels are used. Also, in the process of conducting the sensitivity analysis, the HTC was calculated using the Mokry et al. correlation, which is the most accurate supercritical water heat-transfer correlation so far. The sheath and the fuel centerline temperature profiles were determined for two cases. In Case 1, the HTC was calculated based on the Mokry et al. correlation, while in Case 2, the HTC values calculated for Case 1 were multiplied by a factor of 2. This factor was used in order to identify the amount of decrease in temperatures if the heat transfer is enhanced with appendages. Results of this analysis indicate that the use of the newly developed 54-element fuel bundle along with the proposed fuels is promising when compared with the Variant-20 (43-element) fuel bundle. Overall, the fuel centerline and sheath temperatures were below the industry and design limits when most of the proposed fuels were examined in the 54-element fuel bundle, however, the fuel centerline temperature limit was exceeded while MOX fuel was examined. Keywords: SCWRs, Fuel Centerline Temperature, Sheath Temperature, High Thermal Conductivity Fuels, Low Thermal Conductivity Fuels, HTC.

  6. 78 FR 77490 - Certain Electronic Imaging Devices; Notice of Commission Determination To Review-in-Part a Final...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-23

    ... concluded that two of the accused HTC smartphones, i.e., the HTC Vivid and HTC Droid Incredible 4G LTE... claims of the '538 patent by the HTC Vivid and HTC Droid Incredible 4G LTE smartphones; (2) the technical...

  7. Towards Universal Voluntary HIV Testing and Counselling: A Systematic Review and Meta-Analysis of Community-Based Approaches

    PubMed Central

    Suthar, Amitabh B.; Ford, Nathan; Bachanas, Pamela J.; Wong, Vincent J.; Rajan, Jay S.; Saltzman, Alex K.; Ajose, Olawale; Fakoya, Ade O.; Granich, Reuben M.; Negussie, Eyerusalem K.; Baggaley, Rachel C.

    2013-01-01

    Background Effective national and global HIV responses require a significant expansion of HIV testing and counselling (HTC) to expand access to prevention and care. Facility-based HTC, while essential, is unlikely to meet national and global targets on its own. This article systematically reviews the evidence for community-based HTC. Methods and Findings PubMed was searched on 4 March 2013, clinical trial registries were searched on 3 September 2012, and Embase and the World Health Organization Global Index Medicus were searched on 10 April 2012 for studies including community-based HTC (i.e., HTC outside of health facilities). Randomised controlled trials, and observational studies were eligible if they included a community-based testing approach and reported one or more of the following outcomes: uptake, proportion receiving their first HIV test, CD4 value at diagnosis, linkage to care, HIV positivity rate, HTC coverage, HIV incidence, or cost per person tested (outcomes are defined fully in the text). The following community-based HTC approaches were reviewed: (1) door-to-door testing (systematically offering HTC to homes in a catchment area), (2) mobile testing for the general population (offering HTC via a mobile HTC service), (3) index testing (offering HTC to household members of people with HIV and persons who may have been exposed to HIV), (4) mobile testing for men who have sex with men, (5) mobile testing for people who inject drugs, (6) mobile testing for female sex workers, (7) mobile testing for adolescents, (8) self-testing, (9) workplace HTC, (10) church-based HTC, and (11) school-based HTC. The Newcastle-Ottawa Quality Assessment Scale and the Cochrane Collaboration's “risk of bias” tool were used to assess the risk of bias in studies with a comparator arm included in pooled estimates.  117 studies, including 864,651 participants completing HTC, met the inclusion criteria. The percentage of people offered community-based HTC who accepted HTC was as follows: index testing, 88% of 12,052 participants; self-testing, 87% of 1,839 participants; mobile testing, 87% of 79,475 participants; door-to-door testing, 80% of 555,267 participants; workplace testing, 67% of 62,406 participants; and school-based testing, 62% of 2,593 participants. Mobile HTC uptake among key populations (men who have sex with men, people who inject drugs, female sex workers, and adolescents) ranged from 9% to 100% (among 41,110 participants across studies), with heterogeneity related to how testing was offered. Community-based approaches increased HTC uptake (relative risk [RR] 10.65, 95% confidence interval [CI] 6.27–18.08), the proportion of first-time testers (RR 1.23, 95% CI 1.06–1.42), and the proportion of participants with CD4 counts above 350 cells/µl (RR 1.42, 95% CI 1.16–1.74), and obtained a lower positivity rate (RR 0.59, 95% CI 0.37–0.96), relative to facility-based approaches. 80% (95% CI 75%–85%) of 5,832 community-based HTC participants obtained a CD4 measurement following HIV diagnosis, and 73% (95% CI 61%–85%) of 527 community-based HTC participants initiated antiretroviral therapy following a CD4 measurement indicating eligibility. The data on linking participants without HIV to prevention services were limited. In low- and middle-income countries, the cost per person tested ranged from US$2–US$126. At the population level, community-based HTC increased HTC coverage (RR 7.07, 95% CI 3.52–14.22) and reduced HIV incidence (RR 0.86, 95% CI 0.73–1.02), although the incidence reduction lacked statistical significance. No studies reported any harm arising as a result of having been tested. Conclusions Community-based HTC achieved high rates of HTC uptake, reached people with high CD4 counts, and linked people to care. It also obtained a lower HIV positivity rate relative to facility-based approaches. Further research is needed to further improve acceptability of community-based HTC for key populations. HIV programmes should offer community-based HTC linked to prevention and care, in addition to facility-based HTC, to support increased access to HIV prevention, care, and treatment. Review Registration International Prospective Register of Systematic Reviews CRD42012002554 Please see later in the article for the Editors' Summary PMID:23966838

  8. CFD Modeling and Simulation of Aeorodynamic Cooling of Automotive Brake Rotor

    NASA Astrophysics Data System (ADS)

    Belhocien, Ali; Omar, Wan Zaidi Wan

    Braking system is one of the important control systems of an automotive. For many years, the disc brakes have been used in automobiles for the safe retarding of the vehicles. During the braking enormous amount of heat will be generated and for effective braking sufficient heat dissipation is essential. The thermal performance of disc brake depends upon the characteristics of the airflow around the brake rotor and hence the aerodynamics is an important in the region of brake components. A CFD analysis is carried out on the braking system as a case study to make out the behavior of airflow distribution around the disc brake components using ANSYS CFX software. We are interested in the determination of the heat transfer coefficient (HTC) on each surface of a ventilated disc rotor varying with time in a transient state using CFD analysis, and then imported the surface film condition data into a corresponding FEM model for disc temperature analysis.

  9. 76 FR 75910 - Certain Electronic Imaging Devices; Commission Determination To Affirm Finding of No Violation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... Section 337 by HTC. Specifically, the ALJ found that the accused HTC Android smartphones and the accused... the accused HTC Android smartphones, (2) infringement of the asserted claims of the '769 patent by the... with respect to the '769 patent on the bases that (1) the accused HTC Android smartphones and the...

  10. In-Line Heat Treatment and Hot Rolling

    NASA Astrophysics Data System (ADS)

    Raudensky, M.; Horsky, J.; Hnizdil, M. P.; Pohanka, Kotrbacek M.

    2011-01-01

    In-line heat treatment of rolled materials is becoming increasingly used at hot rolling plants. The advantage of this method is the achievement of required material structure without the necessity of reheating. This paper describes a design procedure for cooling sections for the purpose of obtaining the required structure and mechanical properties. The procedure is typically used for the cooling of tubes, rails, long products and plates. Microstructure and nature of grains, grain size and composition determine the overall mechanical behaviour of steel. Heat treatment provides an efficient way to manipulate the properties of steel by controlling the cooling rate. The rate of cooling is defined by a heat transfer coefficient (HTC). Good controllability of HTC can be reached using either air-water or water nozzles. Thus, an on-line heat treatment with the assistance of spray nozzles enables a manufacturing process that can improve product performance by increasing steel strength, hardness and other desirable characteristics. These techniques also allow selective hardening, such that selective areas of a single object can be subjected to different treatments. An experimental stand designed for the study of cooling steel samples has been built at the Brno University of Technology. The stand comprises a movable trolley containing a test sample which moves under the spray at a given velocity. Sensors indicate the temperature history of the tested material. This experimental stand enables simulation of a variety of cooling regimes and evaluates the final structure of tested samples. The same experimental stand is also a tool for use in the design of cooling sections in order to find the required heat treatment procedure and final structure. Examples of the cooling of rails and tubes are given in the paper.

  11. Removal of uranium from aqueous solution by a low cost and high-efficient adsorbent

    NASA Astrophysics Data System (ADS)

    Liu, Yun-Hai; Wang, You-Qun; Zhang, Zhi-Bin; Cao, Xiao-Hong; Nie, Wen-Bin; Li, Qin; Hua, Rong

    2013-05-01

    In this study, a low-cost and high-efficient carbonaceous adsorbent (HTC-COOH) with carboxylic groups was developed for U(VI) removal from aqueous solution compared with the pristine hydrothermal carbon (HTC). The structure and chemical properties of resultant adsorbents were characterized by Scanning electron microscope (SEM), N2 adsorption-desorption, Fourier transform-infrared spectra (FT-IR) and acid-base titration. The key factors (solution pH, contact time, initial U(VI) concentrations and temperature) affected the adsorption of U(VI) on adsorbents were investigated using batch experiments. The adsorption of U(VI) on HTC and HTC-COOH was pH-dependent, and increased with temperature and initial ion concentration. The adsorption equilibrium of U(VI) on adsorbents was well defined by the Langmuir isothermal equation, and the monolayer adsorption capacity of HTC-COOH was found to be 205.8 mg/g. The kinetics of adsorption was very in accordance with the pseudo-second-order rate model. The adsorption processes of U(VI) on HTC and HTC-COOH were endothermic and spontaneous in nature according to the thermodynamics of adsorption. Furthermore, HTC-COOH could selectively adsorption of U(VI) in aqueous solution containing co-existing ions (Mg2+, Co2+, Ni2+, Zn2+ and Mn2+). From the results of the experiments, it is found that the HTC-COOH is a potential adsorbent for effective removal of U(VI) from polluted water.

  12. Evaluation of Integrated Anaerobic Digestion and Hydrothermal Carbonization for Bioenergy Production

    PubMed Central

    Reza, M. Toufiq; Werner, Maja; Pohl, Marcel; Mumme, Jan

    2014-01-01

    Lignocellulosic biomass is one of the most abundant yet underutilized renewable energy resources. Both anaerobic digestion (AD) and hydrothermal carbonization (HTC) are promising technologies for bioenergy production from biomass in terms of biogas and HTC biochar, respectively. In this study, the combination of AD and HTC is proposed to increase overall bioenergy production. Wheat straw was anaerobically digested in a novel upflow anaerobic solid state reactor (UASS) in both mesophilic (37 °C) and thermophilic (55 °C) conditions. Wet digested from thermophilic AD was hydrothermally carbonized at 230 °C for 6 hr for HTC biochar production. At thermophilic temperature, the UASS system yields an average of 165 LCH4/kgVS (VS: volatile solids) and 121 L CH4/kgVS at mesophilic AD over the continuous operation of 200 days. Meanwhile, 43.4 g of HTC biochar with 29.6 MJ/kgdry_biochar was obtained from HTC of 1 kg digestate (dry basis) from mesophilic AD. The combination of AD and HTC, in this particular set of experiment yield 13.2 MJ of energy per 1 kg of dry wheat straw, which is at least 20% higher than HTC alone and 60.2% higher than AD only. PMID:24962786

  13. The distinctive microbial community improves composting efficiency in a full-scale hyperthermophilic composting plant.

    PubMed

    Yu, Zhen; Tang, Jia; Liao, Hanpeng; Liu, Xiaoming; Zhou, Puxiong; Chen, Zhi; Rensing, Christopher; Zhou, Shungui

    2018-06-07

    The application of conventional thermophilic composting (TC) is limited by poor efficiency. Newly-developed hyperthermophilic composting (HTC) is expected to overcome this shortcoming. However, the characterization of microbial communities associated with HTC remains unclear. Here, we compared the performance of HTC and TC in a full-scale sludge composting plant, and found that HTC running at the hyperthermophilic and thermophilic phases for 21 days, led to higher composting efficiency and techno-economic advantages over TC. Results of high-throughput sequencing showed drastic changes in the microbial community during HTC. Thermaceae (35.5-41.7%) was the predominant family in the hyperthermophilic phase, while the thermophilic phase was dominated by both Thermaceae (28.0-53.3%) and Thermoactinomycetaceae (29.9-36.1%). The change of microbial community could be the cause of continuous high temperature in HTC, and thus improve composting efficiency by accelerating the maturation process. This work has provided theoretical and practical guidance for managing sewage sludge by HTC. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Challenges in the delivery of public HIV testing and counselling (HTC) in Douala, Cameroon: providers perspectives and implications on quality of HTC services.

    PubMed

    Ngangue, Patrice; Gagnon, Marie-Pierre; Bedard, Emmanuelle

    2017-04-08

    The Cameroon government has made HIV testing and counselling (HTC) a priority in its HIV/AIDS strategic plan. However, there is a dearth of literature on the perspectives of providers on the quality of HTC services. The aim of this study was to explore challenges in the provision of HTC services and their implications on quality of HTC services in Douala's district hospitals. Two primary data collection methods supported by the Donabedian's model of healthcare were used to explain the challenges in the provision of HTC services and their implications on quality of HTC services. This consisted of semi-structured individual interviews with 6 nurses and 16 lay counsellors and a non-participant observation of the physical environment for HTC by site. The study sites were the prevention and voluntary testing and counselling centre (PVTCC) of the six district hospitals of the city of Douala. The study reveals concerns about confidentiality and privacy during the counselling sessions due to inadequate and limited space. An absence of consent, even verbal, was reported in one PVTCC. There is no specific accredited training curriculum that leads to a formal registration as a PVTCC staff, and some lay counsellors work without training. Lay counsellors carry the burden of HIV counselling, but the majority of them work for many years without remuneration and recognition. Another quality challenge is the high workload in the district hospitals' lab, which leads to long waiting times for HIV test results, thus contributing to failure to return for results. The findings of this study highlighted some issues such as lack of adequate space and equipment for HIV testing and counselling that hinder the quality of HTC services and should challenge the health authorities of Cameroon on the need to reorganize HTC services and create a national HIV quality assurance program.

  15. Analysis of de novo sequencing and transcriptome assembly and lignocellulolytic enzymes gene expression of Coriolopsis gallica HTC.

    PubMed

    Chen, Yuehong; Cao, Qinghua; Tao, Xiang; Shao, Huanhuan; Zhang, Kun; Zhang, Yizheng; Tan, Xuemei

    2017-03-01

    White-rot basidiomycete Coriolopsis gallica HTC is one of the main biodegraders of poplar. In our previous study, we have shown the strong capacity of C. gallica HTC to degrade lignocellulose. In this study, equal amounts of total RNA fromC. Gallica HTC cultures grown in different conditions were pooled together. Illumina paired-end RNA sequencing was performed, and 13.2 million 90-bp paired-end reads were generated. We chose the Merged Assembly of Oases data-set for the following blast searches and gene ontology analyses. The reads were assembled de novo into 28,034 transcripts (≥ 100 bp) using combined assembly strategy MAO. The transcripts were annotated using Blast2GO. In all, 18,810 transcripts (≥100 bp) achieved BLASTX hits, of which, 7048 transcripts had GO term and 2074 had ECs. The expression level of 11 lignocellulolytic enzyme genes from the assembled C. gallica HTC transcriptome were detected by real-time quantitative polymerase chain reaction. The results showed that expression levels of these genes were affected by carbon source and nitrogen source at the level of transcription. The current abundant transcriptome data allowed the identification of many new transcripts in C. gallica HTC. Data provided here represent the most comprehensive and integrated genomic resources for cloning and identifying genes of interest from C. gallica HTC. Characterization of C. gallica HTC transcriptome provides an effective tool to understand mechanisms underlying cellular and molecular functions of C. gallica HTC.

  16. The Impact of Repeat HIV Testing on Risky Sexual Behavior: Evidence from a Randomized Controlled Trial in Malawi

    PubMed Central

    Delavande, Adeline; Wagner, Zachary; Sood, Neeraj

    2016-01-01

    A significant proportion of HIV-positive adults in sub-Saharan Africa are in serodiscordant relationships. Identification of such serodiscordant couples through couple HIV testing and counseling (HTC) is thought to promote safe sexual behavior and reduce the probability of within couple seroconversion. However, it is possible HTC benefits are not sustained over time and therefore repeated HTC may be more effective at preventing seroconversion than one time HTC. We tested this theory in Zomba, Malawi by randomly assigning 170 serodiscordant couples to receive repeated HTC and 167 serodiscordant couples to receive one time HTC upon study enrollment (control group). We used linear probability models and probit model with couple fixed effects to assess the impact of the intervention on risky sexual behavior. At one-year follow-up, we found that couples that received repeated HTC reported significantly more condom use. However, we found no difference in rate of seroconversion between groups, nor did we find differences in subjective expectations about seroconversion or false beliefs about HIV, two expected pathways of behavior change. We conclude that repeated HTC may promote safe sexual behavior, but this result should be interpreted with caution, as it is inconsistent with the result from biological and subjective outcomes. PMID:27158553

  17. The Impact of Repeat HIV Testing on Risky Sexual Behavior: Evidence from a Randomized Controlled Trial in Malawi.

    PubMed

    Delavande, Adeline; Wagner, Zachary; Sood, Neeraj

    2016-03-01

    A significant proportion of HIV-positive adults in sub-Saharan Africa are in serodiscordant relationships. Identification of such serodiscordant couples through couple HIV testing and counseling (HTC) is thought to promote safe sexual behavior and reduce the probability of within couple seroconversion. However, it is possible HTC benefits are not sustained over time and therefore repeated HTC may be more effective at preventing seroconversion than one time HTC. We tested this theory in Zomba, Malawi by randomly assigning 170 serodiscordant couples to receive repeated HTC and 167 serodiscordant couples to receive one time HTC upon study enrollment (control group). We used linear probability models and probit model with couple fixed effects to assess the impact of the intervention on risky sexual behavior. At one-year follow-up, we found that couples that received repeated HTC reported significantly more condom use. However, we found no difference in rate of seroconversion between groups, nor did we find differences in subjective expectations about seroconversion or false beliefs about HIV, two expected pathways of behavior change. We conclude that repeated HTC may promote safe sexual behavior, but this result should be interpreted with caution, as it is inconsistent with the result from biological and subjective outcomes.

  18. Effects of gamma-irradiation on cotyledon cell separation and pectin solubilisation in hard-to-cook cowpeas.

    PubMed

    Jombo, Talknice Z; Minnaar, Amanda; Taylor, John Rn

    2018-03-01

    Cowpeas stored under high temperature and humidity develop the hard-to-cook defect (HTC). This defect greatly increases cooking times and energy costs. To better understand the mechanisms involved in the HTC defect development, the effects of gamma-irradiation on cotyledon cellular structure and pectin solubility in two cowpea cultivars with different susceptibility to HTC defect were investigated. Gamma-irradiation decreased cotyledon cell wall thickness, increased cell size, and intercellular spaces in both cowpea cultivars and reduced cooking time of the less HTC susceptible cultivar. However, it did not reverse the HTC defect in the susceptible cultivar. Gamma-irradiation also increased the levels of cold water- and hot water-soluble pectin. The irradiation effects were thus mainly due to hydrolysis of pectin fractions in the cell walls. However, chelator-soluble pectin (CSP) solubility was not affected. As the cell wall changes brought about by gamma-irradiation were associated with pectin solubilisation, this supports the phytate-phytase-pectin theory as a major cause of the HTC defect. However, the non-reversal of the defect in HTC susceptible cowpeas and the absence of an effect on CSP indicate that other mechanisms are involved in HTC defect development in cowpeas, possibly the formation of alkali-soluble, ester bonded pectins. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. Novel SNPs in HSPB8 gene and their association with heat tolerance traits in Sahiwal indigenous cattle.

    PubMed

    Verma, Nishant; Gupta, Ishwar Dayal; Verma, Archana; Kumar, Rakesh; Das, Ramendra; Vineeth, M R

    2016-01-01

    Heat shock proteins (HSPs) are expressed in response to heat stress, and the polymorphism in HSP genes at single-nucleotide level has been reported to be associated with heat tolerance and production performance traits in cattle. HSPB8 gene has been mapped on Bos taurus autosome 17 (BTA-17) spanning nearly 13,252 bp and comprising three exons and two introns. The present study was conducted in Sahiwal cows (n = 108) reared in subtropical climate with the objectives to identify SNPs in all three exons and part of intron 1 of HSPB8 gene and to analyze their association with heat tolerance traits in Sahiwal cows. Respiration rate (RR) and rectal temperature (RT) were recorded once during probable extreme hours in different seasons or Temperature-Humidity Index (THI), i.e., winter, spring, and summer. Heat tolerance coefficient (HTC) was also calculated to check the adaptability of the animals during the period of heat stress. The comparative sequence analysis revealed a total two single-nucleotide polymorphisms (SNPs), i.e., g.507G>A in exon 1 and g.881T>C in intron 1 of HSPB8 gene. Out of these two identified SNPs, only one SNP, i.e., g.507G>A, was found to be significantly associated with heat tolerance indicator traits (RR, RT, and HTC) in Sahiwal cows. The perusal of results across different seasons showed the significant (P < 0.01) difference in RR, RT, and HTC between winter, spring, and summer seasons. RR, RT, and HTC were found to be significantly lower (P < 0.01) in GA as compared to GG genotype of g.507G>A SNP of HSPB8 gene. However, in case of another SNP, i.e., g.881T>C, located on intron 1, the RR, RT, and HTC were having non-significant association with the different genotypes, i.e., TT and TC. These findings may partly suggest that GA genotype of SNP g.507G>A of HSPB8 gene has a probable role in heat tolerance in Sahiwal cattle and can therefore be utilized as a marker in propagation of thermo-tolerance cattle in hot tropical and subtropical climate. Nevertheless, the involvement of other regulatory mechanisms cannot be overruled.

  20. Uptake contexts and perceived impacts of HIV testing and counselling among adults in East and Southern Africa: A meta-ethnographic review.

    PubMed

    Witzel, T Charles; Lora, Wezzie; Lees, Shelley; Desmond, Nicola

    2017-01-01

    HIV testing and counselling (HTC) interventions are key to controlling the HIV epidemic in East and Southern Africa where HTC is primarily delivered through voluntary counselling and testing (VCT), provider initiated testing and counselling (PITC), and home-based counselling and testing (HBVCT). Decision making processes around uptake of HTC models must be taken into account when designing new interventions. Counselling in HTC aims to reduce post-test risk taking behaviour and to link individuals to care but its efficacy is unclear. This meta-ethnography aims to understand the contexts of HTC uptake in East and Southern Africa and to analyse the perceived impacts of counselling-based interventions in relation to sexual behaviour and linkage to care. We conducted a systematic literature review of studies investigating HTC in East and Southern Africa from 2003 -April 2014. The search and additional snowballing identified 20 studies that fit our selection criteria. These studies were synthesised through a thematic framework analysis. Twenty qualitative and mixed-methods studies examining impacts of HTC models in East and Southern Africa were meta-synthesised. VCT decisions were made individually while HBVCT decisions were located in family and community units. PITC was associated with coercion from healthcare providers. Low quality counselling components and multiple-intersecting barriers faced by individuals mean that counselling in HTC was not perceived to be effective in reducing post-test risk behaviour and had limited perceived effect in facilitating linkage to care. HBVCT is associated with minimal stigma and should be considered as an area of priority. Counselling components in HTC interventions were effective in transmitting information about HIV and sexual risk, but were perceived as ineffective in addressing the broader personal circumstances preventing sexual behaviour change and modulating access to care.

  1. Analysis of hard-to-cook red and black common beans using Fourier transform infrared spectroscopy.

    PubMed

    Maurer, Giselle A; Ozen, Banu F; Mauer, Lisa J; Nielsen, S Suzanne

    2004-03-24

    Extracted fractions from black and red common beans (Phaseolus vulgaris) were studied using Fourier transform infrared spectroscopy (FT-IR). Beans were stored under three conditions: control at 4 degrees C; hard-to-cook (HTC) at 29 degrees C, 65% RH for 3.5 months; and refrigerated at 2 degrees C, 79% RH for 3.5 months after a HTC period (called HTC-refrigerated). Two fractions isolated from the beans, the soluble pectin fraction (SPF) and the water insoluble residue of the cell wall (WIRCW), were analyzed using diffuse reflectance (DRIFTS) FT-IR. The soaking water and cooking water from the beans were also studied using attenuated total reflectance (ATR) FT-IR. The DRIFTS FT-IR results from the SPF and WIRCW fractions were consistent with previously published data for Carioca beans showing that in general, more phenolic compounds were associated with the SPF of HTC beans than in the control beans. Results also showed that HTC-refrigerated beans had higher concentrations of phenolic compounds than control beans in the SPF. The ATR FT-IR results for soaking and cooking waters from the HTC-refrigerated and HTC beans had higher concentrations of absorbing compounds than the control beans, indicating that they lost more constituents to the water. Additionally, results indicate that the mechanism(s) for reversibility of the HTC defect could be different than the one(s) involved in the development of the defect.

  2. Response of maize germination and growth to HTC filtrate type and concentration

    USDA-ARS?s Scientific Manuscript database

    Hydrothermal carbonization (HTC) is a thermochemical treatment process that allows for the conversion of biomass slurries into value added products. The option of using HTC filtrate as a liquid based fertilizer for agricultural crop production was evaluated through germination and plant growth studi...

  3. Hydrogel tissue construct-based high-content compound screening.

    PubMed

    Lam, Vy; Wakatsuki, Tetsuro

    2011-01-01

    Current pharmaceutical compound screening systems rely on cell-based assays to identify therapeutic candidates and potential toxicities. However, cells grown on 2D substrata or in suspension do not exhibit the mechanical or physiological properties of cells in vivo. To address this limitation, the authors developed an in vitro, high-throughput, 3D hydrogel tissue construct (HTC)-based assay system to quantify cell and tissue mechanical properties and multiple parameters of physiology. HTC mechanics was quantified using an automated device, and physiological status was assessed using spectroscopy-based indicators that were read on microplate readers. To demonstrate the application of this system, the authors screened 4 test compounds--rotenone (ROT), cytochalasin D (CD), 2,4-dinitrophenol (DNP), and Rho kinase inhibitor (H-1152)--for their ability to modulate HTC contractility without affecting actin integrity, mitochondrial membrane potential (MMP), or viability. All 4 compounds dose-dependently reduced HTC contractility. However, ROT was toxic, DNP dissipated MMP, and CD reduced both intracellular F-actin and viability. H-1152 was found to be the best candidate compound since it reduced HTC contractility with minimal side effects. The authors propose that their HTC-based assay system can be used to screen for compounds that modulate HTC contractility and assess the underlying physiological mechanism(s) of compound activity and toxicity.

  4. Impact of hydrochar application on soil nutrient dynamics and plant availability

    NASA Astrophysics Data System (ADS)

    Bargmann, I.; Greef, J. M.; Kücke, M.

    2012-04-01

    In order to investigate potentials for the use of HTC-products (hydrochar) in agriculture, the influence of soil application of different hydrochars on soil nutrient dynamics as well as on plant growth and plant nutrient uptake was determined. Hydrochars were produced from sugar beet pulps and brewer's grains by carbonization at 190°C for 4 respectively 12 hours each. Incubation experiments with two soil types showed an increase of soil pH by 0.5 to 2.5 pH units, depending on the amount of hydrochar added and the process conditions (i.e. addition of calcium carbonate during production). The application of HTC to soil decreased the plant available nitrogen to almost zero in the first week after HTC-addition, followed by a slow re-release of nitrate in the following weeks. A similar immobilization of soluble phosphate was observed for one soil type, although to a lower extent. The plant availability of phosphorus in hydrochars and biochars is subject of current trials. Furthermore it is actually investigated to what extend the N immobilization is related to soil microbial activity. Germination tests with barley showed toxic effects of hydrochar application on germination, both by direct contact of grains with HTC as well as by release of gaseous compounds from HTC. Effects differ significantly for different parent materials and pretreatments (washing, drying, storage). The influence of HTC-addition to soil on plant growth and nutrient uptake was investigated in pot experiments with various crop species (barley, phaseolus bean, leek), comparing HTC from different parent materials and process parameters such as carbonization time. With increasing addition of HTC, the N availability was decreased and N contents in the plant were significantly lower compared with the untreated control. The plant growth response was different for each tested crop. On barley, leaf tip necroses were observed, but not on phaseolus. Biomass yield of barley and beans was generally increased by HTC application. In contrast, leek biomass production was reduced. Our experiences show that HTC-materials should be incorporated into soils several weeks before planting/sowing, similar as it is widely recommended for straw incorporation. Alternatively, HTC can be pretreated by composting or fermentation with fresh organic material to destroy toxic compounds microbially.

  5. Validation of GC-IRMS techniques for δ13C and δ2H CSIA of organophosphorus compounds and their potential for studying the mode of hydrolysis in the environment.

    PubMed

    Wu, Langping; Kümmel, Steffen; Richnow, Hans H

    2017-04-01

    Compound-specific stable isotope analysis (CSIA) is among the most promising tools for studying the fate of organic pollutants in the environment. However, the feasibility of multidimensional CSIA was limited by the availability of a robust method for precise isotope analysis of heteroatom-bearing organic compounds. We developed a method for δ 13 C and δ 2 H analysis of eight organophosphorus compounds (OPs) with different chemical properties. In particular, we aimed to compare high-temperature conversion (HTC) and chromium-based HTC (Cr/HTC) units to explore the limitations of hydrogen isotope analysis of heteroatom-bearing compounds. Analysis of the amount dependency of the isotope values (linearity analysis) of OPs indicated that the formation of HCl was a significant isotope fractionation process leading to inaccurate δ 2 H analysis in HTC. In the case of nonchlorinated OPs, by-product formation of HCN, H 2 S, or PH 3 in HTC was observed but did not affect the dynamic range of reproducible isotope values above the limit of detection. No hydrogen-containing by-products were found in the Cr/HTC process by use of ion trap mass spectrometry analysis. The accuracy of gas chromatography - isotope ratio mass spectrometry was validated in comparison with elemental analyzer - isotope ratio mass spectrometry. Dual-isotope fractionation yielded Λ values of 0 ± 0 at pH 7, 7 ± 1 at pH 9, and 30 ± 6 at pH 12, indicating the potential of 2D CSIA to characterize the hydrolysis mechanisms of OPs. This is the first report on the combination of δ 2 H and δ 13 C isotope analysis of OPs, and this is the first study providing a systematic evaluation of HTC and Cr/HTC for hydrogen isotope analysis using OPs as target compounds. Graphical Abstract Comparison of δ 2 H measurement of non-chlorinated and chlorinated OPs via GC-Cr/HTC-IRMS and GC-HTC-IRMS system.

  6. Methadone Maintenance Treatment Promotes Referral and Uptake of HIV Testing and Counselling Services amongst Drug Users and Their Partners

    PubMed Central

    Nguyen, Lan Phuong; Nguyen, Cuong Tat; Phan, Huong Thi Thu; Latkin, Carl A.

    2016-01-01

    Background Methadone maintenance treatment (MMT) reduces HIV risk behaviors and improves access to HIV-related services among drug users. In this study, we assessed the uptake and willingness of MMT patients to refer HIV testing and counseling (HTC) service to their sexual partners and relatives. Methods Health status, HIV-related risk behaviors, and HTC uptake and referrals of 1,016 MMT patients in Hanoi and Nam Dinh were investigated. Willingness to pay (WTP) for HTC was elicited using a contingent valuation technique. Interval and logistic regression models were employed to determine associated factors. Results Most of the patients (94.2%) had received HTC, 6.6 times on average. The proportion of respondents willing to refer their partners, their relatives and to be voluntary peer educators was 45.7%, 35.3%, and 33.3%, respectively. Attending MMT integrated with HTC was a facilitative factor for HTC uptake, greater WTP, and volunteering as peer educators. Older age, higher education and income, and HIV positive status were positively related to willingness to refer partners or relatives, while having health problems (mobility, usual care, pain/discomfort) was associated with lower likelihood of referring others or being a volunteer. Over 90% patients were willing to pay an average of US $17.9 for HTC service. Conclusion The results highlighted the potential role of MMT patients as referrers to HTC and voluntary peer educators. Integrating HIV testing with MMT services and applying users’ fee are potential strategies to mobilize resources and encourage HIV testing among MMT patients and their partners. PMID:27046029

  7. Home-based HIV testing for men preferred over clinic-based testing by pregnant women and their male partners, a nested cross-sectional study.

    PubMed

    Osoti, Alfred Onyango; John-Stewart, Grace; Kiarie, James Njogu; Barbra, Richardson; Kinuthia, John; Krakowiak, Daisy; Farquhar, Carey

    2015-07-30

    Male partner HIV testing and counseling (HTC) is associated with enhanced uptake of prevention of mother-to-child HIV transmission (PMTCT), yet male HTC during pregnancy remains low. Identifying settings preferred by pregnant women and their male partners may improve male involvement in PMTCT. Participants in a randomized clinical trial (NCT01620073) to improve male partner HTC were interviewed to determine whether the preferred male partner HTC setting was the home, antenatal care (ANC) clinic or VCT center. In this nested cross sectional study, responses were evaluated at baseline and after 6 weeks. Differences between the two time points were compared using McNemar's test and correlates of preference were determined using logistic regression. Among 300 pregnant female participants, 54% preferred home over ANC clinic testing (34.0%) or VCT center (12.0%). Among 188 male partners, 68% preferred home-based HTC to antenatal clinic (19%) or VCT (13%). Men who desired more children and women who had less than secondary education or daily income < $2 USD were more likely to prefer home-based over other settings (p < 0.05 for all comparisons). At 6 weeks, the majority of male (81%) and female (65%) participants recommended home over alternative HTC venues. Adjusting for whether or not the partner was tested during follow-up did not significantly alter preferences. Pregnant women and their male partners preferred home-based compared to clinic or VCT-center based male partner HTC. Home-based HTC during pregnancy appears acceptable and may improve male testing and involvement in PMTCT.

  8. Removal of Dissolved Silica using Calcinated Hydrotalcite in Real-life Applications.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasan, Koroush; Brady, Patrick Vane.; Krumhansl, James L.

    Water shortages are a growing global problem. Reclamation of industrial and municipal wastewater will be necessary in order to mitigate water scarcity. However, many operational challenges, such as silica scaling, prevent large scale water reuse. Previously, our team at Sandia has demonstrated the use of selective ion exchange materials, such as calcinated hydrotalcite (HTC, (Mg 6 Al 2 (OH) 16 (CO 3 )*4H 2 O)), for the low cost removal of silica from synthetic cooling tower water. However, it is not currently know if calcinated HTC has similar capabilities in realistic applications. The purpose of this study was to investigatemore » the ability of calcinated HTC to remove silica from real cooling tower water. This was investigated under both batch and continuous conditions, and in the presence of competing ions. It was determined that calcinated HTC behaved similarly in real and synthetic cooling tower water; the HTC is highly selective for the silica even in the presence of competing cations. Therefore, the data concludes that calcinated HTC is a viable anti-scaling pretreatment for the reuse of industrial wastewaters.« less

  9. Uptake contexts and perceived impacts of HIV testing and counselling among adults in East and Southern Africa: A meta-ethnographic review

    PubMed Central

    Witzel, T. Charles; Lora, Wezzie; Lees, Shelley; Desmond, Nicola

    2017-01-01

    Introduction HIV testing and counselling (HTC) interventions are key to controlling the HIV epidemic in East and Southern Africa where HTC is primarily delivered through voluntary counselling and testing (VCT), provider initiated testing and counselling (PITC), and home-based counselling and testing (HBVCT). Decision making processes around uptake of HTC models must be taken into account when designing new interventions. Counselling in HTC aims to reduce post-test risk taking behaviour and to link individuals to care but its efficacy is unclear. This meta-ethnography aims to understand the contexts of HTC uptake in East and Southern Africa and to analyse the perceived impacts of counselling-based interventions in relation to sexual behaviour and linkage to care. Methods We conducted a systematic literature review of studies investigating HTC in East and Southern Africa from 2003 –April 2014. The search and additional snowballing identified 20 studies that fit our selection criteria. These studies were synthesised through a thematic framework analysis. Results Twenty qualitative and mixed-methods studies examining impacts of HTC models in East and Southern Africa were meta-synthesised. VCT decisions were made individually while HBVCT decisions were located in family and community units. PITC was associated with coercion from healthcare providers. Low quality counselling components and multiple-intersecting barriers faced by individuals mean that counselling in HTC was not perceived to be effective in reducing post-test risk behaviour and had limited perceived effect in facilitating linkage to care. Conclusion HBVCT is associated with minimal stigma and should be considered as an area of priority. Counselling components in HTC interventions were effective in transmitting information about HIV and sexual risk, but were perceived as ineffective in addressing the broader personal circumstances preventing sexual behaviour change and modulating access to care. PMID:28207802

  10. Gaseous byproducts from high-temperature thermal conversion elemental analysis of nitrogen- and sulfur-bearing compounds with considerations for δ2H and δ18O analyses.

    PubMed

    Hunsinger, Glendon B; Tipple, Christopher A; Stern, Libby A

    2013-07-30

    High-temperature, conversion-reduction (HTC) systems convert hydrogen and oxygen in materials into H2 and CO for δ(2)H and δ(18)O measurements by isotope ratio mass spectrometry. HTC of nitrogen- and sulfur-bearing materials produces unintended byproduct gases that could affect isotope analyses by: (1) allowing isotope exchange reactions downstream of the HTC reactor, (2) creating isobaric or co-elution interferences, and (3) causing deterioration of the chromatography. This study characterizes these HTC byproducts. A HTC system (ThermoFinnigan TC/EA) was directly connected to a gas chromatograph/quadrupole mass spectrometer in scan mode (m/z 8 to 88) to identify the volatile products generated by HTC at conversion temperatures of 1350 °C and 1450 °C for a range of nitrogen- and sulfur-bearing solids [keratin powder, horse hair, caffeine, ammonium nitrate, potassium nitrate, ammonium sulfate, urea, and three nitrated organic explosives (PETN, RDX, and TNT)]. The prominent HTC byproduct gases include carbon dioxide, hydrogen cyanide, methane, acetylene, and water for all nitrogen-bearing compounds, as well as carbon disulfide, carbonyl sulfide, and hydrogen sulfide for sulfur-bearing compounds. The 1450 °C reactor temperature reduced the abundance of most byproduct gases, but increased the significant byproduct, hydrogen cyanide. Inclusion of a post-reactor chemical trap containing Ascarite II and Sicapent, in series, eliminated the majority of byproducts. This study identified numerous gaseous HTC byproducts. The potential adverse effects of these gases on isotope ratio analyses are unknown but may be mitigated by higher HTC reactor temperatures and purifying the products with a purge-and-trap system or with chemical traps. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

  11. Behavior of selected hydrolyzed and dehydrated products during hydrothermal carbonization of biomass.

    PubMed

    Reza, M Toufiq; Wirth, Benjamin; Lüder, Ulf; Werner, Maja

    2014-10-01

    In this study, effects of reaction temperature and reaction time on both solid hydrochar and HTC process liquid products were studied for hydrothermal carbonization (HTC) of cellulose, wheat straw, and poplar. A novel slurry sampling system was designed and used with an 18.6L Parr reactor for 0-480 min in 200, 230, and 260 °C. Sugars (sucrose, glucose, and fructose), HMF, and furfural were found maximum in lower HTC temperature and time. However, they degrade following first order degradation kinetics. Activation energies of total sugars (glucose, fructose, sucrose, and xylose), furfural, and HMF for straw and poplar were 95-127, 130-135, and 74-90 kJ mol(-1), respectively and individuals were lower for HTC of cellulose than others. Organic acids (acetic acid, formic acid, and lactic acid) and phenolic compounds (phenol, catechol, and guaiacol) were increasing with higher HTC severity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Modeling physical vapor deposition of energetic materials

    DOE PAGES

    Shirvan, Koroush; Forrest, Eric C.

    2018-03-28

    Morphology and microstructure of organic explosive films formed using physical vapor deposition (PVD) processes strongly depends on local surface temperature during deposition. Currently, there is no accurate means of quantifying the local surface temperature during PVD processes in the deposition chambers. This study focuses on using a multiphysics computational fluid dynamics tool, STARCCM+, to simulate pentaerythritol tetranitrate (PETN) deposition. The PETN vapor and solid phase were simulated using the volume of fluid method and its deposition in the vacuum chamber on spinning silicon wafers was modeled. The model also included the spinning copper cooling block where the wafers are placedmore » along with the chiller operating with forced convection refrigerant. Implicit time-dependent simulations in two- and three-dimensional were performed to derive insights in the governing physics for PETN thin film formation. PETN is deposited at the rate of 14 nm/s at 142.9 °C on a wafer with an initial temperature of 22 °C. The deposition of PETN on the wafers was calculated at an assumed heat transfer coefficient (HTC) of 400 W/m 2 K. This HTC proved to be the most sensitive parameter in determining the local surface temperature during deposition. Previous experimental work found noticeable microstructural changes with 0.5 mm fused silica wafers in place of silicon during the PETN deposition. This work showed that fused silica slows initial wafer cool down and results in ~10 °C difference for the surface temperature at 500 μm PETN film thickness. It was also found that the deposition surface temperature is insensitive to the cooling power of the copper block due to the copper block's very large heat capacity and thermal conductivity relative to the heat input from the PVD process. Future work should incorporate the addition of local stress during PETN deposition. Lastly, based on simulation results, it is also recommended to investigate the impact of wafer surface energy on the PETN microstructure and morphology formation.« less

  13. Modeling physical vapor deposition of energetic materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shirvan, Koroush; Forrest, Eric C.

    Morphology and microstructure of organic explosive films formed using physical vapor deposition (PVD) processes strongly depends on local surface temperature during deposition. Currently, there is no accurate means of quantifying the local surface temperature during PVD processes in the deposition chambers. This study focuses on using a multiphysics computational fluid dynamics tool, STARCCM+, to simulate pentaerythritol tetranitrate (PETN) deposition. The PETN vapor and solid phase were simulated using the volume of fluid method and its deposition in the vacuum chamber on spinning silicon wafers was modeled. The model also included the spinning copper cooling block where the wafers are placedmore » along with the chiller operating with forced convection refrigerant. Implicit time-dependent simulations in two- and three-dimensional were performed to derive insights in the governing physics for PETN thin film formation. PETN is deposited at the rate of 14 nm/s at 142.9 °C on a wafer with an initial temperature of 22 °C. The deposition of PETN on the wafers was calculated at an assumed heat transfer coefficient (HTC) of 400 W/m 2 K. This HTC proved to be the most sensitive parameter in determining the local surface temperature during deposition. Previous experimental work found noticeable microstructural changes with 0.5 mm fused silica wafers in place of silicon during the PETN deposition. This work showed that fused silica slows initial wafer cool down and results in ~10 °C difference for the surface temperature at 500 μm PETN film thickness. It was also found that the deposition surface temperature is insensitive to the cooling power of the copper block due to the copper block's very large heat capacity and thermal conductivity relative to the heat input from the PVD process. Future work should incorporate the addition of local stress during PETN deposition. Lastly, based on simulation results, it is also recommended to investigate the impact of wafer surface energy on the PETN microstructure and morphology formation.« less

  14. Chlorophyll-Based Organic-Inorganic Heterojunction Solar Cells.

    PubMed

    Li, Yue; Zhao, Wenjie; Li, Mengzhen; Chen, Gang; Wang, Xiao-Feng; Fu, Xueqi; Kitao, Osamu; Tamiaki, Hitoshi; Sakai, Kotowa; Ikeuchi, Toshitaka; Sasaki, Shin-Ichi

    2017-08-10

    Solid-state chlorophyll solar cells (CSCs) employing a carboxylated chlorophyll derivative, methyl trans-3 2 -carboxypyropheophorbide a, as a light-harvesting dye sensitizer chlorophyll (DSC) deposited on mesoporous TiO 2 , on which four zinc hydroxylated chlorophyll derivatives were spin-coated for hole transporter chlorophylls (HTCs), are described. Key parameters, including the effective carrier mobility of the HTC films, as determined by the space charge-limited current method, and the frontier molecular orbitals of these DSCs and HTCs, as estimated from cyclic voltammetry and electronic absorption spectra, suggest that both charge separation and carrier transport are favorable. The power conversion efficiencies (PCEs) of the present CSCs with fluorine-doped tin oxide (FTO)/TiO 2 /DSC/HTCs/Ag were determined to follow the order of HTC-1>HTC-2>HTC-3>HTC-4, which coincided perfectly with the order of their hole mobilities. The maximum PCE achieved was 0.86 % with HTC-1. The photovoltaic devices studied herein with two types of chlorophyll derivatives as dye sensitizers and hole transporters provide a unique solution for the utilization of solar energy with a view to truly realizing "green energy". © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Nutrient retention and fate of iron-binding phenolic compounds during the injera processing of tannin-free and high-tannin sorghum.

    PubMed

    Seyoum, Yohannes; Retta, Negussie; Baye, Kaleab

    2016-03-30

    Traits such as bird-, insect- and mould-resistance are the focus in selecting improved sorghum varieties, but this often increases the tannin content, which can negatively affect iron bioavailability. The grain characteristics, nutrient retention, and the fate of iron-binding polyphenols (IBPs) during injera processing, an Ethiopian traditional fermented pancake, were investigated using agriculturally improved tannin-free (TFC) and high-tannin (HTC) sorghum cultivars. The HTC had significantly higher IBP contents than the TFC (P < 0.05). Decortication led to iron (24-27%), calcium (18-43%), IBP (catechol 35-41%, galloyl 35-42%), and tannin (12-35%) losses. Sourdough fermentation reduced the IBP and tannin concentrations in HTC, but had no effect on the IBP concentrations in TFC. The modified injera processing that included pre-soaking resulted in the highest IBP reductions (galloyl 73% and catechol 71%). Nutrient retention in HTC and TFC processing was different. Including a pre-soaking step during injera processing of HTC could counter the negative effects of IBP on iron absorption, while benefiting from the agronomic features of HTC. © 2015 Society of Chemical Industry.

  16. Mixing HTC and HPC Workloads with HTCondor and Slurm

    NASA Astrophysics Data System (ADS)

    Hollowell, C.; Barnett, J.; Caramarcu, C.; Strecker-Kellogg, W.; Wong, A.; Zaytsev, A.

    2017-10-01

    Traditionally, the RHIC/ATLAS Computing Facility (RACF) at Brookhaven National Laboratory (BNL) has only maintained High Throughput Computing (HTC) resources for our HEP/NP user community. We’ve been using HTCondor as our batch system for many years, as this software is particularly well suited for managing HTC processor farm resources. Recently, the RACF has also begun to design/administrate some High Performance Computing (HPC) systems for a multidisciplinary user community at BNL. In this paper, we’ll discuss our experiences using HTCondor and Slurm in an HPC context, and our facility’s attempts to allow our HTC and HPC processing farms/clusters to make opportunistic use of each other’s computing resources.

  17. Evaluation of the performance of high temperature conversion reactors for compound-specific oxygen stable isotope analysis.

    PubMed

    Hitzfeld, Kristina L; Gehre, Matthias; Richnow, Hans-Hermann

    2017-05-01

    In this study conversion conditions for oxygen gas chromatography high temperature conversion (HTC) isotope ratio mass spectrometry (IRMS) are characterised using qualitative mass spectrometry (IonTrap). It is shown that physical and chemical properties of a given reactor design impact HTC and thus the ability to accurately measure oxygen isotope ratios. Commercially available and custom-built tube-in-tube reactors were used to elucidate (i) by-product formation (carbon dioxide, water, small organic molecules), (ii) 2nd sources of oxygen (leakage, metal oxides, ceramic material), and (iii) required reactor conditions (conditioning, reduction, stability). The suitability of the available HTC approach for compound-specific isotope analysis of oxygen in volatile organic molecules like methyl tert-butyl ether is assessed. Main problems impeding accurate analysis are non-quantitative HTC and significant carbon dioxide by-product formation. An evaluation strategy combining mass spectrometric analysis of HTC products and IRMS 18 O/ 16 O monitoring for future method development is proposed.

  18. Impact of HIV testing and counseling (HTC) knowledge on HIV prevention practices among traditional birth attendants in Nigeria.

    PubMed

    Osuji, Alice; Pharr, Jennifer R; Nwokoro, Uche; Ike, Anulika; Ali, Christiana; Ejiro, Ogheneaga; Osuyali, John; Obiefune, Michael; Fiscella, Kevin; Ezeanolue, Echezona E

    2015-02-10

    Nigeria is second in the world for the number of people with HIV and has a high rate of mother-to-child transmission (MTCT). Over 60% of births in Nigeria occur outside of health care facilities, and because of this, Traditional Birth Attendants (TBAs) play a significant role in maternal and child health. It is important that TBAs be knowledgeable about HIV prevention. The purpose of this study was to determine the impact of HIV testing and counseling (HTC) knowledge on the HIV prevention practices among TBAs in Nigeria. Five hundred TBAs were surveyed. Chi-square and logistic regression were used to assess differences in HIV prevention practices between TBAs with and without HTC knowledge. TBAs with HTC knowledge are significantly more likely to engage in HIV prevention practices than TBAs without HTC. Prevention practices included: wearing gloves during delivery (p < 0.01), sterilization of delivery equipment (p < 0.01), participation in blood safety training (p < 0.01), and disposal of sharps (p < 0.01). As long as a high percent of births occur outside health care facilities in Nigeria, there will be a need for TBAs. Providing TBAs with HTC training increases HIV prevention practices and can be a key to improve maternal and child health.

  19. Impact of HIV Testing and Counseling (HTC) Knowledge on HIV Prevention Practices Among Traditional Birth Attendants in Nigeria

    PubMed Central

    Osuji, Alice; Pharr, Jennifer R.; Nwokoro, Uche; Ike, Anulika; Ali, Christiana; Ejiro, Ogheneaga; Osuyali, John; Obiefune, Michael; Fiscella, Kevin; Ezeanolue, Echezona E.

    2015-01-01

    Nigeria is second in the world for the number of people with HIV and has a high rate of mother-to-child transmission (MTCT). Over 60% of births in Nigeria occur outside of health care facilities, and because of this, Traditional Birth Attendants (TBAs) play a significant role in maternal and child health. It is important that TBAs be knowledgeable about HIV prevention. The purpose of this study was to determine the impact of HIV testing and counseling (HTC) knowledge on the HIV prevention practices among TBAs in Nigeria. Five hundred TBAs were surveyed. Chi-square and logistic regression were used to assess differences in HIV prevention practices between TBAs with and without HTC knowledge. TBAs with HTC knowledge are significantly more likely to engage in HIV prevention practices than TBAs without HTC. Prevention practices included: wearing gloves during delivery (p < 0.01), sterilization of delivery equipment (p < 0.01), participation in blood safety training (p < 0.01), and disposal of sharps (p < 0.01). As long as a high percent of births occur outside health care facilities in Nigeria, there will be a need for TBAs. Providing TBAs with HTC training increases HIV prevention practices and can be a key to improve maternal and child health. PMID:25674783

  20. Thermal conversion of municipal solid waste via hydrothermal carbonization: comparison of carbonization products to products from current waste management techniques.

    PubMed

    Lu, Xiaowei; Jordan, Beth; Berge, Nicole D

    2012-07-01

    Hydrothermal carbonization (HTC) is a novel thermal conversion process that may be a viable means for managing solid waste streams while minimizing greenhouse gas production and producing residual material with intrinsic value. HTC is a wet, relatively low temperature (180-350 °C) thermal conversion process that has been shown to convert biomass to a carbonaceous residue referred to as hydrochar. Results from batch experiments indicate HTC of representative waste materials is feasible, and results in the majority of carbon (45-75% of the initially present carbon) remaining within the hydrochar. Gas production during the batch experiments suggests that longer reaction periods may be desirable to maximize the production of energy-favorable products. If using the hydrochar for applications in which the carbon will remain stored, results suggest that the gaseous products from HTC result in fewer g CO(2)-equivalent emissions than the gases associated with landfilling, composting, and incineration. When considering the use of hydrochar as a solid fuel, more energy can be derived from the hydrochar than from the gases resulting from waste degradation during landfilling and anaerobic digestion, and from incineration of food waste. Carbon emissions resulting from the use of the hydrochar as a fuel source are smaller than those associated with incineration, suggesting HTC may serve as an environmentally beneficial alternative to incineration. The type and extent of environmental benefits derived from HTC will be dependent on hydrochar use/the purpose for HTC (e.g., energy generation or carbon storage). Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Multi-threaded integration of HTC-Vive and MeVisLab

    NASA Astrophysics Data System (ADS)

    Gunacker, Simon; Gall, Markus; Schmalstieg, Dieter; Egger, Jan

    2018-03-01

    This work presents how Virtual Reality (VR) can easily be integrated into medical applications via a plugin for a medical image processing framework called MeVisLab. A multi-threaded plugin has been developed using OpenVR, a VR library that can be used for developing vendor and platform independent VR applications. The plugin is tested using the HTC Vive, a head-mounted display developed by HTC and Valve Corporation.

  2. Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer-chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS).

    PubMed

    Gehre, Matthias; Renpenning, Julian; Geilmann, Heike; Qi, Haiping; Coplen, Tyler B; Kümmel, Steffen; Ivdra, Natalija; Brand, Willi A; Schimmelmann, Arndt

    2017-03-30

    Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H 2 ) is responsible for non-quantitative H 2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer-Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. The modified EA-Cr/HTC reactor setup showed an overall H 2 -recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Exceptional selectivity for dissolved silicas in industrial waters using mixed oxides

    DOE PAGES

    Sasan, Koroush; Brady, Patrick V.; Krumhansl, James L.; ...

    2017-11-07

    The removal of silica, ubiquitous in produced and industrial waters, by novel mixed oxides is investigated in this present study. We have combined the advantage of high selectivity hydrotalcite (HTC, (Mg 6Al 2(OH) 16(CO 3)·4H 2O)), with large surface area of active alumina (AA, (Al 2O 3)) for effective removing of the dissolved silica from cooling tower water. The batch test results indicated the combined HTC/AA is a more effective method for removing silica from CTW than using each of HTC or AA separately. The silica uptake was confirmed by Fourier transform infrared (FTIR), and Energy dispersive spectroscopy (EDS). Ourmore » results indicate HTC/AA effectively removes silica from cooling tower water (CTW), even in the presence of large concentrations of competing anions, such as Cl -, NO 3 - HCO 3 -, CO 3 2- and SO 4 2-. The Single Path Flow Through (SPFT) tests confirmed to rapid uptake of silica by combined HTC/AA during column filtration. The experimental data of silica adsorption fit best to Freundlich isotherm model.« less

  4. Exceptional selectivity for dissolved silicas in industrial waters using mixed oxides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasan, Koroush; Brady, Patrick V.; Krumhansl, James L.

    The removal of silica, ubiquitous in produced and industrial waters, by novel mixed oxides is investigated in this present study. We have combined the advantage of high selectivity hydrotalcite (HTC, (Mg 6Al 2(OH) 16(CO 3)·4H 2O)), with large surface area of active alumina (AA, (Al 2O 3)) for effective removing of the dissolved silica from cooling tower water. The batch test results indicated the combined HTC/AA is a more effective method for removing silica from CTW than using each of HTC or AA separately. The silica uptake was confirmed by Fourier transform infrared (FTIR), and Energy dispersive spectroscopy (EDS). Ourmore » results indicate HTC/AA effectively removes silica from cooling tower water (CTW), even in the presence of large concentrations of competing anions, such as Cl -, NO 3 - HCO 3 -, CO 3 2- and SO 4 2-. The Single Path Flow Through (SPFT) tests confirmed to rapid uptake of silica by combined HTC/AA during column filtration. The experimental data of silica adsorption fit best to Freundlich isotherm model.« less

  5. Client characteristics and gender-specific correlates of testing HIV positive: a comparison of standalone center versus mobile outreach HIV testing and counseling in Botswana.

    PubMed

    Hood, Julia E; MacKellar, Duncan; Spaulding, Anne; Nelson, Rob; Mosiakgabo, Boingotlo; Sikwa, Bangwato; Puso, Innocentia; Raats, Jan; Loeto, Peter; Alwano, Mary Grace; Monyatsi, Blessed

    2012-10-01

    Using data from Botswana's largest HIV testing and counseling (HTC) provider, Tebelopele, we evaluate populations served and gender-specific correlates of testing HIV-positive among clients of two programs: standalone centers and outreach testing. Client records from January to June 2007 (n = 47,890) were evaluated by HTC program and gender. Bivariate and multivariate analyses were performed to identify demographic, testing, and risk-behavior variables associated with testing HIV-positive. Compared to outreach testing, standalone centers served proportionally more clients who were young, well-educated, unmarried, and HIV-infected; outreach testing reached an older, less-educated population. Age, educational attainment, marital status, couples testing, testing because of illness or discordant relationship, and nonuse of condoms (among young clients only) were consistently associated with testing HIV-positive, by HTC program and gender. Our evaluation suggests that Tebelopele standalone and outreach HTC programs serve different populations, and identifies strategies to reduce HIV infection risk and to improve uptake of HTC by HIV-infected, undiagnosed Batswana.

  6. Nitrogen-Doped Carbon Nanotube-Supported Pd Catalyst for Improved Electrocatalytic Performance toward Ethanol Electrooxidation

    NASA Astrophysics Data System (ADS)

    Wei, Ying; Zhang, Xinyuan; Luo, Zhiyong; Tang, Dian; Chen, Changxin; Zhang, Teng; Xie, Zailai

    2017-07-01

    In this study, hydrothermal carbonization (HTC) was applied for surface functionalization of carbon nanotubes (CNTs) in the presence of glucose and urea. The HTC process allowed the deposition of thin nitrogen-doped carbon layers on the surface of the CNTs. By controlling the ratio of glucose to urea, nitrogen contents of up to 1.7 wt% were achieved. The nitrogen-doped carbon nanotube-supported Pd catalysts exhibited superior electrochemical activity for ethanol oxidation relative to the pristine CNTs. Importantly, a 1.5-fold increase in the specific activity was observed for the Pd/HTC-N1.67%CNTs relative to the catalyst without nitrogen doping (Pd/HTC-CNTs). Further experiments indicated that the introduction of nitrogen species on the surface of the CNTs improved the Pd(0) loading and increased the binding energy.

  7. Assessment of hydrothermal carbonization and coupling washing with torrefaction of bamboo sawdust for biofuels production.

    PubMed

    Zhang, Shuping; Su, Yinhai; Xu, Dan; Zhu, Shuguang; Zhang, Houlei; Liu, Xinzhi

    2018-06-01

    Two kinds of biofuels were produced and compared from hydrothermal carbonization (HTC) and coupling washing with torrefaction (CWT) processes of bamboo sawdust in this study. The mass and energy yields, mass energy density, fuel properties, structural characterizations, combustion behavior and ash behavior during combustion process were investigated. Significant increases in the carbon contents resulted in the improvement of mass energy density and fuel properties of biofuels obtained. Both HTC and CWT improved the safety of the biofuels during the process of handling, storing and transportation. The ash-related issues of the biofuels were significantly mitigated and combustion behavior was remarkably improved after HTC and CWT processes of bamboo sawdust. In general, both HTC and CWT processes are suitable to produce biofuels with high fuel quality from bamboo sawdust. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Wastewater treatment--adsorption of organic micropollutants on activated HTC-carbon derived from sewage sludge.

    PubMed

    Kirschhöfer, Frank; Sahin, Olga; Becker, Gero C; Meffert, Florian; Nusser, Michael; Anderer, Gilbert; Kusche, Stepan; Klaeusli, Thomas; Kruse, Andrea; Brenner-Weiss, Gerald

    2016-01-01

    Organic micropollutants (MPs), in particular xenobiotics and their transformation products, have been detected in the aquatic environment and the main sources of these MPs are wastewater treatment plants. Therefore, an additional cleaning step is necessary. The use of activated carbon (AC) is one approach to providing this additional cleaning. Industrial AC derived from different carbonaceous materials is predominantly produced in low-income countries by polluting processes. In contrast, AC derived from sewage sludge by hydrothermal carbonization (HTC) is a regional and sustainable alternative, based on waste material. Our experiments demonstrate that the HTC-AC from sewage sludge was able to remove most of the applied MPs. In fact more than 50% of sulfamethoxazole, diclofenac and bezafibrate were removed from artificial water samples. With the same approach carbamazepine was eliminated to nearly 70% and atrazine more than 80%. In addition a pre-treated (phosphorus-reduced) HTC-AC was able to eliminate 80% of carbamazepine and diclofenac. Atrazine, sulfamethoxazole and bezafibrate were removed to more than 90%. Experiments using real wastewater samples with high organic content (11.1 g m(-3)) succeeded in proving the adsorption capability of phosphorus-reduced HTC-AC.

  9. Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer–chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS)

    USGS Publications Warehouse

    Gehre, Matthias; Renpenning, Julian; Geilmann, Heike; Qi, Haiping; Coplen, Tyler B.; Kümmel, Steffen; Ivdra, Natalija; Brand, Willi A.; Schimmelmann, Arndt

    2017-01-01

    Conclusions: The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd.

  10. A Primer on High-Throughput Computing for Genomic Selection

    PubMed Central

    Wu, Xiao-Lin; Beissinger, Timothy M.; Bauck, Stewart; Woodward, Brent; Rosa, Guilherme J. M.; Weigel, Kent A.; Gatti, Natalia de Leon; Gianola, Daniel

    2011-01-01

    High-throughput computing (HTC) uses computer clusters to solve advanced computational problems, with the goal of accomplishing high-throughput over relatively long periods of time. In genomic selection, for example, a set of markers covering the entire genome is used to train a model based on known data, and the resulting model is used to predict the genetic merit of selection candidates. Sophisticated models are very computationally demanding and, with several traits to be evaluated sequentially, computing time is long, and output is low. In this paper, we present scenarios and basic principles of how HTC can be used in genomic selection, implemented using various techniques from simple batch processing to pipelining in distributed computer clusters. Various scripting languages, such as shell scripting, Perl, and R, are also very useful to devise pipelines. By pipelining, we can reduce total computing time and consequently increase throughput. In comparison to the traditional data processing pipeline residing on the central processors, performing general-purpose computation on a graphics processing unit provide a new-generation approach to massive parallel computing in genomic selection. While the concept of HTC may still be new to many researchers in animal breeding, plant breeding, and genetics, HTC infrastructures have already been built in many institutions, such as the University of Wisconsin–Madison, which can be leveraged for genomic selection, in terms of central processing unit capacity, network connectivity, storage availability, and middleware connectivity. Exploring existing HTC infrastructures as well as general-purpose computing environments will further expand our capability to meet increasing computing demands posed by unprecedented genomic data that we have today. We anticipate that HTC will impact genomic selection via better statistical models, faster solutions, and more competitive products (e.g., from design of marker panels to realized genetic gain). Eventually, HTC may change our view of data analysis as well as decision-making in the post-genomic era of selection programs in animals and plants, or in the study of complex diseases in humans. PMID:22303303

  11. Prevalence of HIV testing and counseling and associated factors among secondary school students in Botswana.

    PubMed

    Bodika, Stephane M; Lekone, Phenyo E; Loeto, Peter; Alwano, Mary G; Zulu, Thekiso C; Kim, Evelyn; Machao, Gape; Voetsch, Andrew C

    2016-05-01

    The World Health Organization recommends HIV testing and counseling (HTC) for all adolescents living in countries with generalized HIV epidemics. In Botswana, HIV prevalence among adolescents 15-19 years is 3.7% and among pregnant adolescents is 10%. We describe the proportion and characteristics of secondary school students who have accessed HTC. A multistage sample survey was conducted among students in Botswana's public secondary schools in 2010. The survey was self-administered using a personal digital assistant device. The HTC rate was estimated using self-reported history of HIV testing. Of 1,632 participants, 52% were girls, 43% aged below 16 years, and 27% had ever had sexual intercourse. Most (81%) students knew where to get tested for HIV. Overall, 2.2% of students were HIV positive by self-report. The HTC rate was 23% overall, 34% among students who had ever had sexual intercourse, and 45% among students who had sexual intercourse in the past 12 months. Being pregnant or having made someone pregnant and having had sexual intercourse in the past 12 months were associated with having been tested for HIV among students who had ever had sexual intercourse. Overall, the HTC rate was low, and the self- reported HIV prevalence was high among secondary students in Botswana. Most sexually active students have never been tested for HIV. Health communications efforts for adolescents that increase demand for HTC, routine opt-out HIV testing in healthcare facilities, and school-based HIV testing are needed as part of a national HIV prevention strategy.

  12. "Students want HIV testing in schools" a formative evaluation of the acceptability of HIV testing and counselling at schools in Gauteng and North West provinces in South Africa.

    PubMed

    Madiba, Sphiwe; Mokgatle, Mathilda

    2015-04-17

    The proposal by the South African Health Ministry to implement HIV testing and counselling (HTC) at schools in 2011 generated debates about the appropriateness of such testing. However, the debate has been between the Ministries of Education and Health, with little considerations of the students. The main aim of the study was to assess the students' opinions and uptake of HIV testing and counselling in general, and the acceptability of the provision of HIV testing and counselling in schools. The study also determined the association between socio-demographic characteristics, sexual behaviour, and HIV testing behaviour of the students. A survey was conducted among grade 10-12 high school students in North West and Gauteng provinces, South Africa. Seventeen high schools (nine rural and eight urban) were randomly selected for the administration of a researcher-assisted, self-administered, semi-structured questionnaire. A total of 2970 students aged 14-27 years participated in the study; 1632 (55%) were girls, 1810 (61%) ever had sex, and 1271 (49.8%) had more than one sex partner. The mean age of first sexual activity was 15.6. Half (n = 1494, 50.1%) had been tested for HIV. Having multiple sexual partners, age, and gender were significantly associated with increased odds of having had a HIV test. Fear, being un-informed about HTC, and low HIV risk perceptions were the reasons for not getting tested. The acceptability of HTC at school was high (n = 2282, 76.9%) and 2129 (71.8%) were willing to be tested at school. Appropriateness, privacy, and secrecy were the main arguments for and against HTC at school. One-third (n = 860, 29%) had intentions to disclose their HIV status to students versus 1258 (42.5%) for teachers. Stigma, discrimination and secrecy were the primary reasons students did not intend to disclose. A high acceptability of HTC and willingness to be tested at school suggest that HIV prevention programs tailored to youth have a high potential of success given the readiness of students to uptake HTC. Bringing HIV testing to the school setting will increase the uptake of HTC among youth and contribute towards efforts to scale up HTC in South Africa.

  13. Uptake and linkage into care over one year of providing HIV testing and counselling through community and health facility testing modalities in urban informal settlement of Kibera, Nairobi Kenya.

    PubMed

    Muhula, Samuel; Memiah, Peter; Mbau, Lilian; Oruko, Happiness; Baker, Bebora; Ikiara, Geoffrey; Mungai, Margaret; Ndirangu, Meshack; Achwoka, Dunstan; Ilako, Festus

    2016-05-04

    We examine the uptake of HIV Testing and Counselling (HTC) and linkage into care over one year of providing HTC through community and health facility testing modalities among people living in Kibera informal urban settlement in Nairobi Kenya. We analyzed program data on health facility-based HIV testing and counselling and community- based testing and counselling approaches for the period starting October 2013 to September 2014. Univariate and bivariate analysis methods were used to compare the two approaches with regard to uptake of HTC and subsequent linkage to care. The exact Confidence Intervals (CI) to the proportions were approximated using simple normal approximation to binomial distribution method. Majority of the 18,591 clients were tested through health facility-based testing approaches 72.5 % (n = 13485) vs those tested through community-based testing comprised 27.5 % (n = 5106). More clients tested at health facilities were reached through Provider Initiated Testing and Counselling PITC 81.7 % (n = 11015) while 18.3 % were reached through Voluntary Counselling and Testing (VCT)/Client Initiated Testing and Counselling (CITC) services. All clients who tested positive during health facility-based testing were successfully linked to care either at the project sites or sites of client choice while not all who tested positive during community based testing were linked to care. The HIV prevalence among all those who were tested for HIV in the program was 5.2 % (n = 52, 95 % CI: 3.9 %-6.8 %). Key study limitation included use of aggregate data to report uptake of HTC through the two testing approaches and not being able to estimate the population in the catchment area likely to test for HIV. Health facility-based HTC approach achieved more clients tested for HIV, and this method also resulted in identifying greater numbers of people who were HIV positive in Kibera slum within one year period of testing for HIV compared to community-based HTC approach. Linking HIV positive clients to care proved much easier during health facility- based HTC compared to community- based HTC.

  14. Implementation and Operational Research: Strengthening HIV Test Access and Treatment Uptake Study (Project STATUS): A Randomized Trial of HIV Testing and Counseling Interventions.

    PubMed

    McNaghten, A D; Schilsky Mneimneh, Allison; Farirai, Thato; Wamai, Nafuna; Ntiro, Marylad; Sabatier, Jennifer; Makhunga-Ramfolo, Nondumiso; Mwanasalli, Salli; Awor, Anna; Moore, Jan

    2015-12-01

    To determine which of 3 HIV testing and counseling (HTC) models in outpatient departments (OPDs) increases HIV testing and entry of newly identified HIV-infected patients into care. Randomized trial of HTC interventions. Thirty-six OPDs in South Africa, Tanzania, and Uganda were randomly assigned to 3 different HTC models: (A) health care providers referred eligible patients (aged 18-49, not tested in the past year, not known HIV positive) to on-site voluntary counseling and testing for HTC offered and provided by voluntary counseling and testing counselors after clinical consultation; (B) health care providers offered and provided HTC to eligible patients during clinical consultation; and (C) nurse or lay counselors offered and provided HTC to eligible patients before clinical consultation. Data were collected from October 2011 to September 2012. We describe testing eligibility and acceptance, HIV prevalence, and referral and entry into care. Chi-square analyses were conducted to examine differences by model. Of 79,910 patients, 45% were age eligible and 16,099 (45%) age eligibles were tested. Ten percent tested HIV positive. Significant differences were found in percent tested by model. The proportion of age eligible patients tested by Project STATUS was highest for model C (54.1%, 95% confidence interval [CI]: 42.4 to 65.9), followed by model A (41.7%, 95% CI: 30.7 to 52.8), and then model B (33.9%, 95% CI: 25.7 to 42.1). Of the 1596 newly identified HIV positive patients, 94% were referred to care (96.1% in model A, 94.7% in model B, and 94.9% in model C), and 58% entered on-site care (74.4% in model A, 54.8% in model B, and 55.6% in model C) with no significant differences in referrals or care entry by model. Model C resulted in the highest proportion of all age-eligible patients receiving a test. Although 94% of STATUS patients with a positive test result were referred to care, only 58% entered care. We found no differences in patients entering care by HTC model. Routine HTC in OPDs is acceptable to patients and effective for identifying HIV-infected persons, but additional efforts are needed to increase entry to care.

  15. Experience and lessons from health impact assessment guiding prevention and control of HIV/AIDS in a copper mine project, northwestern Zambia.

    PubMed

    Knoblauch, Astrid M; Divall, Mark J; Owuor, Milka; Nduna, Kennedy; Ng'uni, Harrison; Musunka, Gertrude; Pascall, Anna; Utzinger, Jürg; Winkler, Mirko S

    2017-07-04

    To avoid or mitigate potential project-related adverse health effects, the Trident copper project in Kalumbila, northwestern Zambia, commissioned a health impact assessment. HIV was identified a priority health issue based on the local vulnerability to HIV transmission and experience from other mining projects in Africa. Hence, an HIV/AIDS management plan was developed, including community and workplace interventions, with HIV testing and counselling (HTC) being one of the key components. We present trends in HTC data over a 4-year period. In 13 communities affected by the Trident project, HTC was implemented from 2012 onwards, using rapid diagnostic tests, accompanied by pre- and post-test counselling through trained personnel. In addition, HTC was initiated in the project workforce in 2013, coinciding with the launch of the mine development. HTC uptake and HIV positivity rates were assessed in the study population and linked to demographic factors using regression analysis. In total, 11,638 community members and 5564 workers have taken up HTC with an increase over time. The HIV positivity rate in the community was 3.0% in 2012 and 3.4% in 2015, while positivity rate in the workforce was 5.2% in 2013 and 4.3% in 2015. Females showed a significantly higher odds of having a positive test result than males (odds ratio (OR) = 1.96, 95% confidence interval (CI): 1.55-2.50 among women in the community and OR = 2.90, 95% CI: 1.74-4.84 among women in the workforce). HTC users in the 35-49 years age group were most affected by HIV, with an average positivity rate of 6.6% in the community sample and 7.9% in the workforce sample. These study groups had 4.50 and 4.95 higher odds of being positive, respectively, compared to their younger counterparts (15-24 years). While HTC uptake increased five-fold in the community and almost three-fold in the workplace, the HIV positivity rates were insignificantly higher in 2015 compared to 2012. Our data can be used alongside other surveillance data to track HIV transmission in this specific context. Guided by the health impact assessment, the HIV prevention and control programme was readily adapted to the current setting through the identification of socioeconomic and environmental determinants of health.

  16. Identification of SNP in HSP90AB1 and its association with the relative thermotolerance and milk production traits in Indian dairy cattle.

    PubMed

    Sajjanar, Basavaraj; Deb, Rajib; Singh, Umesh; Kumar, Sushil; Brahmane, Manoj; Nirmale, Avinash; Bal, Santanu Kumar; Minhas, P S

    2015-01-01

    Heat shock proteins (Hsp) play crucial role in cellular thermotolerance and heat stress response. In the present work, Allele specific PCR (AS-PCR) was standardized to detect the nucleotide polymorphism within the HSP90AB1 gene (SNP g.4338T>C) in Indian breeds of dairy cattle. The identified genotypes were associated with relative thermotolerance in terms of physiological parameters and milk production traits. The results of the experiments revealed that the genotype frequency of CC, CT, and TT for Sahiwal were 0.05, 0.78, and 0.17, respectively, and in Frieswal, the frequencies were 0.20, 0.70, and 0.10, respectively. The average rectal temperature (ART) and average respiration rates (ARR) were recorded during peak summer stress and heat tolerance coefficient (HTC) was calculated. The association studies indicated that TT genotypes had significantly (P < 0.01) higher HTC and lower ARR values than CT and CC in both the breeds. The TT genotype animals also had better production parameter in terms of total milk yield (TMY) (P < 0.01). These findings may partly suggest the role of HSP90AB1 polymorphisms in the regulation of heat stress response and consequent effect on production traits. Nevertheless, involvement of other regulatory mechanisms cannot be overruled.

  17. Short Message Service (SMS) Command and Control (C2) Awareness in Android-based Smartphones Using Kernel-Level Auditing

    DTIC Science & Technology

    2012-06-14

    Display 480 x 800 pixels (3.7 inches) CPU Qualcomm QSD8250 1GHz Memory (internal) 512MB RAM / 512 MB ROM Kernel version 2.6.35.7-ge0fb012 Figure 3.5: HTC...development and writing). The 34 MSM kernel provided by the AOSP and compatible with the HTC Nexus One’s motherboard and Qualcomm chipset, is used for this...building the kernel is having the prebuilt toolchains and the right kernel for the hardware. Many HTC products use Qualcomm processors which uses the

  18. Waste Water for Power Generation via Energy Efficient Selective Silica Separations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nenoff, Tina M.; Brady, Patrick Vane; Sasan, Koroush

    Silica is ubiquitous in produced and industrial waters, and plays a major disruptive role in water recycle. Herein we have investigated the use of mixed oxides for the removal of silica from these waters, and their incorporation into a low cost and low energy water purification process. High selectivity hydrotalcite (HTC, (Mg 6Al 2(OH) 16(CO 3)•4H 2O)), is combined in series with high surface area active alumina (AA, (Al 2O 3)) as the dissolved silica removal media. Batch test results indicated that combined HTC/AA is a more effective method for removing silica from industrial cooling tower wasters (CTW) than usingmore » HTC or AA separately. The silica uptake via ion exchange on the mixed oxides was confirmed by Fourier transform infrared (FTIR), and Energy dispersive spectroscopy (EDS). Furthermore, HTC/AA effectively removes silica from CTW even in the presence of large concentrations of competing anions, such as Cl -, NO 3 - HCO 3 -, CO 3 2- and SO 4 2-. Similar to batch tests, Single Path Flow Through (SPFT) tests with sequential HTC/AA column filtration has very high silica removal too. Technoeconomic Analysis (TEA) was simultaneously performed for cost comparisons to existing silica removal technologies.« less

  19. Hepatoma tissue culture (HTC) cells as a model for investigating the effects of low concentrations of herbicide on cell structure and function.

    PubMed

    Malatesta, M; Perdoni, F; Santin, G; Battistelli, S; Muller, S; Biggiogera, M

    2008-12-01

    Previous studies on mice fed genetically modified (GM) soybean demonstrated modifications of the mitochondrial functions and of the transcription/splicing pathways in hepatocytes. The cause(s) of these alterations could not be conclusively established but, since the GM soybean used is tolerant to glyphosate and was treated with the glyphosate-containing herbicide Roundup , the possibility exists that the effects observed may be due to herbicide residues. In order to verify this hypothesis, we treated HTC cells with 1-10mM Roundup and analysed cellular features by flow cytometry, fluorescence and electron microscopy. Under these experimental conditions, the death rate and the general morphology of HTC cells were not affected, as well as most of the cytoplasmic organelles. However, in HTC-treated cells, lysosome density increased and mitochondrial membranes modified indicating a decline in the respiratory activity. Moreover, nuclei underwent morpho-functional modifications suggestive of a decreased transcriptional/splicing activity. Although we cannot exclude that other factors than the presence of the herbicide residues could be responsible for the cellular modifications described in GM-fed mice, the concordance of the effects induced by low concentrations of Roundup on HTC cells suggests that the presence of Roundup residues could be one of the factors interfering with multiple metabolic pathways.

  20. Hydrothermal carbonization of animal manures: Processes and energetics

    USDA-ARS?s Scientific Manuscript database

    Hydrothermal carbonization (HTC) is an emerging technology for thermochemically converting biomass and waste materials into value-added carbonaceous char called hydrochar. HTC is well suited to manage wet feedstocks streams because pre-drying prior to processing is not required as with gasification...

  1. Hydrothermal conversion of xylose, glucose, and cellulose under the catalysis of transition metal sulfates.

    PubMed

    Cao, Xuefei; Peng, Xinwen; Sun, Shaoni; Zhong, Linxin; Chen, Wei; Wang, Sha; Sun, Run-Cang

    2015-03-15

    Hydrothermal conversion (HTC) is an important thermochemical process to upgrade low-cost biomass into valuable chemicals or fuels. As compared with non-catalytic HTC, catalytic HTC shows high energy efficiency on biomass upgradation. In this work, the catalytic performances of various transition metal sulfates (Mn(2+), Fe(2+), Fe(3+), Co(2+), Ni(2+), Cu(2+), and Zn(2+)) in the HTCs of xylose, glucose, and cellulose under different conditions were explored. Among these catalysts, Zn(2+) and Ni(2+) showed obvious effects on the conversions of xylose, glucose, and cellulose into lactic acid, while Cu(2+) and Fe(3+), which could significantly accelerate the hydrolysis of cellulose into glucose at 200°C, displayed high efficiency on converting glucose and cellulose into levulinic acid and formic acid at high temperature. Additionally, significant positive correlative relationships among xylose, glucose, and cellulose degradations were observed. This study is helpful for screening appropriate catalysts for biomass upgradation through catalytic HTC of monosaccharide. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Co-gasification of bituminous coal and hydrochar derived from municipal solid waste: Reactivity and synergy.

    PubMed

    Wei, Juntao; Guo, Qinghua; He, Qing; Ding, Lu; Yoshikawa, Kunio; Yu, Guangsuo

    2017-09-01

    In this work, the influences of gasification temperature and blended ratio on co-gasification reactivity and synergy of Shenfu bituminous coal (SF) and municipal solid waste-derived hydrochar (HTC) were investigated using TGA. Additionally, active alkaline and alkaline earth metal (AAEM) transformation during co-gasification was quantitatively analyzed by inductively coupled plasma optical emission spectrometer for correlating synergy on co-gasification reactivity. The results showed that higher char gasification reactivity existed at higher HTC char proportion and gasification temperature, and the main synergy behaviour on co-gasification reactivity was performed as synergistic effect. Enhanced synergistic effect at lower temperature was mainly resulted from more obviously inhibiting the primary AAEM (i.e. active Ca) transformation, and weak synergistic effect still existed at higher temperature since more active K with prominent catalysis was retained. Furthermore, more active HTC-derived AAEM remaining in SF sample during co-gasification would lead to enhanced synergistic effect as HTC char proportion increased. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Hydrothermal carbonization of typical components of municipal solid waste for deriving hydrochars and their combustion behavior.

    PubMed

    Lin, Yousheng; Ma, Xiaoqian; Peng, Xiaowei; Yu, Zhaosheng

    2017-11-01

    In this work, five typical components were employed as representative pseudo-components to indirectly complete previous established simulation system during hydrothermal carbonization (HTC) of municipal solid waste. The fuel characteristics and combustion behavior of HTC-derived hydrochars were evaluated. Results clearly illustrated that the energy ranks of hydrochars were upgraded after HTC. For paper and wood, superior combustion performances of their hydrochars could achieve under suitable conditions. While for food, none positive enrichments on combustion loss rate were observed for hydrochars due to its high solubilization and decomposition under hot compressed water. It was noteworthy that a new weight loss peak was detected for paper and food, suggesting that new compounds were formed. For rubber, the HTC process made the properties of styrene butadiene rubber more close to natural rubber. Therefore, the first peak of hydrochars became significantly intense. While for plastic, only physical changes of polypropylene and polyethylene were observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. 78 FR 32689 - Certain Portable Electronic Communications Devices, Including Mobile Phones and Components...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-31

    ..., Including Mobile Phones and Components Thereof Notice of Receipt of Complaint; Solicitation of Comments... Certain Portable Electronic Communications Devices, Including Mobile Phones and Components Thereof, DN... mobile phones and components thereof. The complaint names as respondents HTC Corporation of China and HTC...

  5. A comparative study for the organic byproducts from hydrothermal carbonizations of sugarcane bagasse and its bio-refined components cellulose and lignin.

    PubMed

    Du, Fang-Li; Du, Qi-Shi; Dai, Jun; Tang, Pei-Duo; Li, Yan-Ming; Long, Si-Yu; Xie, Neng-Zhong; Wang, Qing-Yan; Huang, Ri-Bo

    2018-01-01

    Sugarcane bagasse was refined into cellulose, hemicellulose, and lignin using an ethanol-based organosolv technique. The hydrothermal carbonization (HTC) reactions were applied for bagasse and its two components cellulose and lignin. Based on GC-MS analysis, 32 (13+19) organic byproducts were derived from cellulose and lignin, more than the 22 byproducts from bagasse. Particularly, more valuable catechol products were obtained from lignin with 56.8% share in the total GC-MS integral area, much higher than the 2.263% share in the GC-MS integral areas of bagasse. The organic byproducts from lignin make up more than half of the total mass of lignin, indicating that lignin is a chemical treasure storage. In general, bio-refinery and HTC are two effective techniques for the valorization of bagasse and other biomass materials from agriculture and forest industry. HTC could convert the inferior biomass to superior biofuel with higher energy quantity of combustion, at the same time many valuable organic byproducts are produced. Bio-refinery could promote the HTC reaction of biomass more effective. With the help of bio-refinery and HTC, bagasse and other biomass materials are not only the sustainable energy resource, but also the renewable and environment friendly chemical materials, the best alternatives for petroleum, coal and natural gas.

  6. Biochar Treatment Resulted in a Combined Effect on Soybean Growth Promotion and a Shift in Plant Growth Promoting Rhizobacteria

    PubMed Central

    Egamberdieva, Dilfuza; Wirth, Stephan; Behrendt, Undine; Abd_Allah, Elsayed F.; Berg, Gabriele

    2016-01-01

    The application of biochar to soil is considered to have the potential for long-term soil carbon sequestration, as well as for improving plant growth and suppressing soil pathogens. In our study we evaluated the effect of biochar on the plant growth of soybeans, as well as on the community composition of root-associated bacteria with plant growth promoting traits. Two types of biochar, namely, maize biochar (MBC), wood biochar (WBC), and hydrochar (HTC) were used for pot experiments to monitor plant growth. Soybean plants grown in soil amended with HTC char (2%) showed the best performance and were collected for isolation and further characterization of root-associated bacteria for multiple plant growth promoting traits. Only HTC char amendment resulted in a statistically significant increase in the root and shoot dry weight of soybeans. Interestingly, rhizosphere isolates from HTC char amended soil showed higher diversity than the rhizosphere isolates from the control soil. In addition, a higher proportion of isolates from HTC char amended soil compared with control soil was found to express plant growth promoting properties and showed antagonistic activity against one or more phytopathogenic fungi. Our study provided evidence that improved plant growth by biochar incorporation into soil results from the combination of a direct effect that is dependent on the type of char and a microbiome shift in root-associated beneficial bacteria. PMID:26941730

  7. Parents Support Implementation of HIV Testing and Counseling at School: Cross-Sectional Study with Parents of Adolescent Attending High School in Gauteng and North West Provinces, South Africa

    PubMed Central

    Mokgatle, Mathildah

    2016-01-01

    Background. A formative assessment of the implementation of HIV testing and counseling (HTC) at school showed high acceptability and willingness to test among learners. However, the success of the proposed HTC depends on the support and acceptability of key stakeholders, including the parents. The aim of the study was to assess the opinions and acceptability of the implementation of HTC at school among parents of adolescents in high school. Methods. This was a cross-sectional household survey conducted with parents of adolescents attending high schools in educational districts in North West and Gauteng provinces, South Africa. Results. A total of 804 parents participated, and 548 (68.3%) were biological mothers, 85 (10.6%) were fathers, and the remaining were other relatives including grandmothers. Almost all (n = 742, 92.9%) parents were in support of implementation and provision of HTC at school, 701 (87.7%) would allow their children to be tested at school, 365 (46%) felt that parental consent was not needed to test at school, and 39.4% preferred to receive the HIV test results with their children. Conclusion. Parents accept the roll-out of an HTC program at school and have a role to play in supporting children who test positive for HIV. PMID:27807481

  8. Hydrothermal carbonization of municipal solid waste for carbon sequestration and energy generation

    USDA-ARS?s Scientific Manuscript database

    A fairly new, innovative technique, called hydrothermal carbonization (HTC), has the potential to change the way municipal solid waste (MSW) is managed. HTC is a wet, low temperature (180-350°C), low pressure (in a closed system) thermochemical waste treatment/conversion technology that has been sho...

  9. Hydrothermal carbonization of biomass residuals: A comparative review of the chemistry, processes and applications of wet and dry pyrolysis

    USDA-ARS?s Scientific Manuscript database

    This paper reviews chemistry, processes and application of hydrothermcally carbonized biomass wastes. Potential feedstock for the hydrothermal carbonization (HTC) includes variety of the non-traditional renewable wet agricultural and municipal waste streams. Pyrolysis and HTC show a comparable calor...

  10. Impact of two hydrothermal carbonization filtrates on soil greenhouse production

    USDA-ARS?s Scientific Manuscript database

    Hydrothermal carbonization (HTC) is a thermochemical treatment process that allows for the conversion of wet biomass slurries to new liquid and solid products. A majority of the research to date has focused on the solid HTC product (hydrochar). Less attention has been paid to the utilization of the ...

  11. From Industry to Teaching: The Quality Instruction Program at Hocking Technical College.

    ERIC Educational Resources Information Center

    Moran, Ralph; And Others

    This presentation on Hocking Technical College's (HTC's) Quality Instruction Program (QIP) provides a program description and comments from three HTC faculty members who have been involved in the program in various ways. Recognizing that many faculty members are hired on the basis of their industrial credentials rather than their teaching…

  12. 76 FR 76759 - Certain Portable Communication Devices, Receipt of Complaint; Solicitation of Comments Relating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... Park, New Jersey; Samsung Telecommunications America, LLC of Richardson, TX; Sony Corporation of Japan; Sony Corporation of America of New York, NY; Sony Electronics, Inc. of San Diego, CA; Sony Ericsson...; Research In Motion Corp. of Irving, TX; HTC Corporation of Taiwan; HTC America, Inc. of Bellevue, WA; LG...

  13. Synthesis and characterization of carbon nanospheres obtained by hydrothermal carbonization of wood-derived and other saccharides

    Treesearch

    Qiangu Yan; Rui Li; Hossein Toghiani; Zhiyong Cai; Jilei Zhang

    2015-01-01

    Carbon nanospheres were synthesized by hydrothermal carbonization (HTC) of four different carbon sources: xylose, glucose, sucrose, and pine wood derived saccharides. The obtained carbon nanospheres were characterized for particle morphology and size, and surface functional groups. Morphological and structural differences among these saccharides derived HTC carbons...

  14. Hydrothermal carbonization (HTC) of wheat straw: influence of feedwater pH prepared by acetic acid and potassium hydroxide.

    PubMed

    Reza, M Toufiq; Rottler, Erwin; Herklotz, Laureen; Wirth, Benjamin

    2015-04-01

    In this study, influence of feedwater pH (2-12) was studied for hydrothermal carbonization (HTC) of wheat straw at 200 and 260°C. Acetic acid and KOH were used as acidic and basic medium, respectively. Hydrochars were characterized by elemental and fiber analyses, SEM, surface area, pore volume and size, and ATR-FTIR, while HTC process liquids were analyzed by HPLC and GC. Both hydrochar and HTC process liquid qualities vary with feedwater pH. At acidic pH, cellulose and elemental carbon increase in hydrochar, while hemicellulose and pseudo-lignin decrease. Hydrochars produced at pH 2 feedwater has 2.7 times larger surface area than that produced at pH 12. It also has the largest pore volume (1.1 × 10(-1) ml g(-1)) and pore size (20.2 nm). Organic acids were increasing, while sugars were decreasing in case of basic feedwater, however, phenolic compounds were present only at 260°C and their concentrations were increasing in basic feedwater. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Heat and ultraviolet light treatment of colostrum and hospital milk: effects on colostrum and hospital milk characteristics and calf health and growth parameters.

    PubMed

    Teixeira, A G V; Bicalho, M L S; Machado, V S; Oikonomou, G; Kacar, C; Foditsch, C; Young, R; Knauer, W A; Nydam, D V; Bicalho, R C

    2013-08-01

    The aim of this study was to evaluate the effects of different physical treatments of bovine colostrum and hospital milk on milk bacteriology, immunoglobulin G (IgG) and lactoferrin concentrations, calf serum IgG concentrations and calf health, growth and survivability. Pooled colostrum samples (n=297) were heat treated (HTC; 63°C for 60 min), exposed to ultraviolet light (UVC; 45 J/cm(2)) or untreated ('raw', RC). Hospital milk (n=712) was subjected to high temperature short time pasteurization (HTST; 72°C for 15s), ultraviolet light irradiation (UVH; 45 J/cm(2)) or was untreated. Neonatal Holstein heifer calves (n=875) were randomly enrolled (309 HTC, 285 UVC, 281 RC) and block randomized (by colostrum treatment) into hospital milk treatments HTST (n=449) or UVH (n=426). HTC was more effective than UVC and HTST was more effective than UVH in reducing bacterial counts. IgG and lactoferrin concentrations were significantly lower in HTC and UVC than in RC. Lactoferrin concentrations were significantly lower in HTST than in UVH or untreated hospital milk. There were no significant differences in serum IgG concentrations among calves fed HTC, UVC or RC. Colostrum and hospital milk treatments did not have any significant effect on calf body weight gain, survivability, or frequency of diarrhea or pneumonia. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Pharmaceuticals in water, fish and osprey nestlings in Delaware River and Bay

    USGS Publications Warehouse

    Bean, Thomas G.; Rattner, Barnett A.; Lazarus, Rebecca S.; Day, Daniel D.; Burket, S. Rebekah; Brooks, Bryan W.; Haddad, Samuel P.; Bowerman, William W.

    2018-01-01

    Exposure of wildlife to Active Pharmaceutical Ingredients (APIs) is likely to occur but studies of risk are limited. One exposure pathway that has received attention is trophic transfer of APIs in a water-fish-osprey food chain. Samples of water, fish plasma and osprey plasma were collected from Delaware River and Bay, and analyzed for 21 APIs. Only 2 of 21 analytes exceeded method detection limits in osprey plasma (acetaminophen and diclofenac) with plasma levels typically 2–3 orders of magnitude below human therapeutic concentrations (HTC). We built upon a screening level model used to predict osprey exposure to APIs in Chesapeake Bay and evaluated whether exposure levels could have been predicted in Delaware Bay had we just measured concentrations in water or fish. Use of surface water and BCFs did not predict API concentrations in fish well, likely due to fish movement patterns, and partitioning and bioaccumulation uncertainties associated with these ionizable chemicals. Input of highest measured API concentration in fish plasma combined with pharmacokinetic data accurately predicted that diclofenac and acetaminophen would be the APIs most likely detected in osprey plasma. For the majority of APIs modeled, levels were not predicted to exceed 1 ng/mL or method detection limits in osprey plasma. Based on the target analytes examined, there is little evidence that APIs represent a significant risk to ospreys nesting in Delaware Bay. If an API is present in fish orders of magnitude below HTC, sampling of fish-eating birds is unlikely to be necessary. However, several human pharmaceuticals accumulated in fish plasma within a recommended safety factor for HTC. It is now important to expand the scope of diet-based API exposure modeling to include alternative exposure pathways (e.g., uptake from landfills, dumps and wastewater treatment plants) and geographic locations (developing countries) where API contamination of the environment may represent greater risk.

  17. 77 FR 515 - Certain Portable Communication Devices; Receipt of Amended Complaint; Solicitation of Comments...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-05

    ... Telecommunications America, LLC of Richardson, TX; Sony Corporation of Japan; Sony Corporation of America of New York, NY; Sony Electronics, Inc. of San Diego, CA; Sony Ericsson Mobile Communication AB of Sweden; Sony... Corp. of Irving, TX; HTC Corporation of Taiwan; HTC America, Inc. of Bellevue, WA; LG Electronics, Inc...

  18. 77 FR 17094 - In the Matter of Certain Portable Communication Devices Commission Determination Not To Review an...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... Richardson, Texas; Sony Corporation of Tokyo, Japan; Sony Corporation of America of New York, New York; Sony Electronics, Inc. of San Diego, California; Sony Ericsson Mobile Communications AB of Lund, Sweden; Sony...; Research In Motion Corp. of Irving, Texas; HTC Corporation of Taoyuan, Taiwan; HTC America, Inc. of...

  19. Implementation of human thermal comfort information in Köppen-Geiger climate classification—the example of China

    NASA Astrophysics Data System (ADS)

    Yang, Shi-Qi; Matzarakis, Andreas

    2016-11-01

    Köppen-Geiger climate classification (KGC) is accepted and applied worldwide. The climatic parameters utilised in KGC, however, cannot indicate human thermal comfort (HTC) conditions or air humidity (AH) conditions directly, because they are originally based on climatic effects on vegetation, instead of that on human body directly. In addition, HTC is driven by meteorological parameters together. Thus, the objective of this study is to preliminarily implement the HTC information and the AH information in KGC. Physiologically equivalent temperature (PET) has been chosen as the HTC index, and vapour pressure (VP) is for the quantification of AH conditions. In this preliminary study, 12 Chinese cities in total have been taken into account as the assumed representatives of 11 climate types. Basic meteorological data of each city with 3-h resolution in 2000-2012 has been analysed. RayMan model has been applied to calculate PET within the same time period. Each climate type has been described by frequencies of PET and frequencies of VP. For example, the Aw (Sanya) has the most frequent occurrence of thermally stressful conditions compared to other climate types: PET in 22 % points in time of the year was above 35 °C. The driest AH conditions existed in Dwc (Lhasa) and Dfb (Urumqi) with VP rarely above 18 hPa in the wettest month. Implementation of the HTC information and the additional AH information in each climate type of KGC can be helpful for the topics of human health, energy consumption, tourism, as well as urban planning.

  20. Implementation of human thermal comfort information in Köppen-Geiger climate classification-the example of China.

    PubMed

    Yang, Shi-Qi; Matzarakis, Andreas

    2016-11-01

    Köppen-Geiger climate classification (KGC) is accepted and applied worldwide. The climatic parameters utilised in KGC, however, cannot indicate human thermal comfort (HTC) conditions or air humidity (AH) conditions directly, because they are originally based on climatic effects on vegetation, instead of that on human body directly. In addition, HTC is driven by meteorological parameters together. Thus, the objective of this study is to preliminarily implement the HTC information and the AH information in KGC. Physiologically equivalent temperature (PET) has been chosen as the HTC index, and vapour pressure (VP) is for the quantification of AH conditions. In this preliminary study, 12 Chinese cities in total have been taken into account as the assumed representatives of 11 climate types. Basic meteorological data of each city with 3-h resolution in 2000-2012 has been analysed. RayMan model has been applied to calculate PET within the same time period. Each climate type has been described by frequencies of PET and frequencies of VP. For example, the Aw (Sanya) has the most frequent occurrence of thermally stressful conditions compared to other climate types: PET in 22 % points in time of the year was above 35 °C. The driest AH conditions existed in Dwc (Lhasa) and Dfb (Urumqi) with VP rarely above 18 hPa in the wettest month. Implementation of the HTC information and the additional AH information in each climate type of KGC can be helpful for the topics of human health, energy consumption, tourism, as well as urban planning.

  1. Pharmaceutical load in sewage sludge and biochar produced by hydrothermal carbonization.

    PubMed

    vom Eyser, C; Palmu, K; Schmidt, T C; Tuerk, J

    2015-12-15

    We investigated the removal of twelve pharmaceuticals in sewage sludge by hydrothermal carbonization (HTC), which has emerged as a technology for improving the quality of organic waste materials producing a valuable biochar material. In this study, the HTC converted sewage sludge samples to a biochar product within 4h at a temperature of 210 °C and a resulting pressure of about 15 bar. Initial pharmaceutical load of the sewage sludge was investigated as well as the residual concentrations in biochar produced from spiked and eight native sewage sludge samples from three waste water treatment plants. Additionally, the solid contents of source material and product were compared, which showed a considerable increase of the solid content after filtration by HTC. All pharmaceuticals except sulfamethoxazole, which remained below the limit of quantification, frequently occurred in the investigated sewage sludges in the μg/kg dry matter (DM) range. Diclofenac, carbamazepine, metoprolol and propranolol were detected in all sludge samples with a maximum concentration of 800 μg/kgDM for metoprolol. HTC was investigated regarding its contaminant removal efficiency using spiked sewage sludge. Pharmaceutical concentrations were reduced for seven compounds by 39% (metoprolol) to≥97% (carbamazepine). In native biochar samples the four compounds phenazone, carbamazepine, metoprolol and propranolol were detected, which confirmed that the HTC process can reduce the load of micropollutants. In contrast to the other investigated compounds phenazone concentration increased, which was further addressed in thermal behaviour studies including three structurally similar potential precursors. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Expanding HIV testing and counselling into communities: Feasibility, acceptability, and effects of an integrated family planning/HTC service delivery model by Village Health Teams in Uganda.

    PubMed

    Brunie, Aurélie; Wamala-Mucheri, Patricia; Akol, Angela; Mercer, Sarah; Chen, Mario

    2016-10-01

    Improving HIV testing and counselling (HTC) requires a range of strategies. This article reports on HTC service delivery by Village Health Teams (VHTs) in Uganda in the context of a model integrating this new component into pre-existing family planning services. Eight health centres from matched pairs were randomly allocated to intervention or control. After being trained, 36 VHTs reporting to selected facilities in the intervention group started offering HTC along with family planning, while VHTs in the control group provided family planning only. Proficiency testing was conducted as external quality assurance. A survey of all 36 VHTs and 137 family planning clients in the intervention group and 119 clients in the control group and a review of record data were conducted after 10 months. Survey responses by VHTs and their clients in the intervention group demonstrate knowledge of counselling messages and safe testing. External quality assessment results provide additional evidence of competency. Eighty per cent of the family planning clients surveyed in the intervention group received an HIV test during the intervention; 27% of those were first-time testers. More clients had ever tested for HIV in the intervention group compared with the control; clients also retested more often. Findings indicate that this model is feasible and acceptable for expanding quality HTC into communities. This study was registered with ClinicalTrials.gov, number [NCT02244398]. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Use of two varieties of hard-to-cook beans (Phaseolus vulgaris) and cowpeas (Vigna unguiculata) in the processing of koki (a steamed legume product).

    PubMed

    Mbofung, C M; Rigby, N; Waldron, K

    1999-01-01

    Koki is a nutritious cowpea-based food product usually processed by steam cooking whipped cowpea (Vigna unguiculata) paste mixed with spices and palm oil. A study was carried out to investigate the effect of the partial replacement of cowpeas (CP) with hard-to-cook (HTC) beans on the chemical, nutritional and sensory characteristics of koki. Towards this objective, two varieties of beans--Phaseolus vulgaris (red kidney beans--RKB and mottled brown beans--MBB), each with the HTC defect, were separately incorporated into cowpea paste in the following Bean:CP ratios 0:100, 20:80, 30:70, 40:60, 50:50, 60:40 and processed into koki. Incorporation of dry HTC beans into cowpeas in the making of koki affected the bulking properties of the uncooked paste, the nutrient composition, essential amino acid content, antinutritional factors, digestibility as well as the sensory attributes of cooked koki. Sensory tests showed that a highly acceptable, nutritious and digestible koki can be processed from cowpeas partially replaced with dry HTC bean paste up to levels of about 40-50% depending on the variety of dry bean used.

  4. [Comparisons of different methods for virus-elimination of edible fungi].

    PubMed

    Zhang, Chao-hui; Liu, Ying-miao; Qi, Yuan-cheng; Gao, Yu-qian; Shen, Jin-wen; Qiu, Li-you

    2010-05-01

    Four dsRNA bands were extracted from Pleurotus ostreatus TD300 by the dsRNA isolation technique with sizes of 8.2 kb, 2.5 kb, 2.1 kb, and 1.1 kb, respectively. Four virus-eliminated methods, i. e. hyphal tips cut (HTC), protoplast regeneration (PR), single spore hybridization (SSH), and frozen and lyophilized (FL), were applied to prepare virus-eliminated strains, and one virus-eliminated strain was selected for each virus-elimination method. The virus-eliminated strains were named as HTC8, PR15, FL01, and SSH11, respectively. There were low concentration of 8.2 kb dsRNA remained in HTC8, as well as low concentration of 8.2 kb and 2.5 kb dsRNA remained in FL01. However, no dsRNA remained in PR15 and SSH11. The hyphal growth rate and laccase activity of the virus-eliminated strains increased, especially HTC8 and PR15, whose hyphal growth rate was higher by 22.73% and 18.18%, and laccase activities higher by 145.83% and 134.38% than that of the original strain, respectively. The conclusion is that hyphal tips cut and protoplast regeneration are suitable to prepare virus-eliminated strains of edible fungi.

  5. Cost-Effective Additive Manufacturing in Space: HELIOS Technology Challenge Guide

    NASA Technical Reports Server (NTRS)

    DeVieneni, Alayna; Velez, Carlos Andres; Benjamin, David; Hollenbeck, Jay

    2012-01-01

    Welcome to the HELIOS Technology Challenge Guide. This document is intended to serve as a general road map for participants of the HELIOS Technology Challenge [HTC] Program and the associated inaugural challenge: HTC-01: Cost-Effective Additive Manufacturing in Space. Please note that this guide is not a rule book and is not meant to hinder the development of innovative ideas. Its primary goal is to highlight the objectives of the HTC-01 Challenge and to describe possible solution routes and pitfalls that such technology may encounter in space. Please also note that participants wishing to demonstrate any hardware developed under this program during any future HELIOS Technology Challenge showcase event(s) may be subject to event regulations to be published separately at a later date.

  6. Cost-effectiveness of community-based strategies to strengthen the continuum of HIV care in rural South Africa: a health economic modelling analysis.

    PubMed

    Smith, Jennifer A; Sharma, Monisha; Levin, Carol; Baeten, Jared M; van Rooyen, Heidi; Celum, Connie; Hallett, Timothy B; Barnabas, Ruanne V

    2015-04-01

    Home HIV counselling and testing (HTC) achieves high coverage of testing and linkage to care compared with existing facility-based approaches, particularly among asymptomatic individuals. In a modelling analysis we aimed to assess the effect on population-level health and cost-effectiveness of a community-based package of home HTC in KwaZulu-Natal, South Africa. We parameterised an individual-based model with data from home HTC and linkage field studies that achieved high coverage (91%) and linkage to antiretroviral therapy (80%) in rural KwaZulu-Natal, South Africa. Costs were derived from a linked microcosting study. The model simulated 10,000 individuals over 10 years and incremental cost-effectiveness ratios were calculated for the intervention relative to the existing status quo of facility-based testing, with costs discounted at 3% annually. The model predicted implementation of home HTC in addition to current practice to decrease HIV-associated morbidity by 10–22% and HIV infections by 9–48% with increasing CD4 cell count thresholds for antiretroviral therapy initiation. Incremental programme costs were US$2·7 million to $4·4 million higher in the intervention scenarios than at baseline, and costs increased with higher CD4 cell count thresholds for antiretroviral therapy initiation; antiretroviral therapy accounted for 48–87% of total costs. Incremental cost-effectiveness ratios per disability-adjusted life-year averted were $1340 at an antiretroviral therapy threshold of CD4 count lower than 200 cells per μL, $1090 at lower than 350 cells per μL, $1150 at lower than 500 cells per μL, and $1360 at universal access to antiretroviral therapy. Community-based HTC with enhanced linkage to care can result in increased HIV testing coverage and treatment uptake, decreasing the population burden of HIV-associated morbidity and mortality. The incremental cost-effectiveness ratios are less than 20% of South Africa's gross domestic product per person, and are therefore classed as very cost effective. Home HTC can be a viable means to achieve UNAIDS' ambitious new targets for HIV treatment coverage. National Institutes of Health, Bill & Melinda Gates Foundation, Wellcome Trust.

  7. Comparison of Oculus Rift and HTC Vive: Feasibility for Virtual Reality-Based Exploration, Navigation, Exergaming, and Rehabilitation.

    PubMed

    Borrego, Adrián; Latorre, Jorge; Alcañiz, Mariano; Llorens, Roberto

    2018-06-01

    The latest generation of head-mounted displays (HMDs) provides built-in head tracking, which enables estimating position in a room-size setting. This feature allows users to explore, navigate, and move within real-size virtual environments, such as kitchens, supermarket aisles, or streets. Previously, these actions were commonly facilitated by external peripherals and interaction metaphors. The objective of this study was to compare the Oculus Rift and the HTC Vive in terms of the working range of the head tracking and the working area, accuracy, and jitter in a room-size environment, and to determine their feasibility for serious games, rehabilitation, and health-related applications. The position of the HMDs was registered in a 10 × 10 grid covering an area of 25 m 2 at sitting (1.3 m) and standing (1.7 m) heights. Accuracy and jitter were estimated from positional data. The working range was estimated by moving the HMDs away from the cameras until no data were obtained. The HTC Vive provided a working area (24.87 m 2 ) twice as large as that of the Oculus Rift. Both devices showed excellent and comparable performance at sitting height (accuracy up to 1 cm and jitter <0.35 mm), and the HTC Vive presented worse but still excellent accuracy and jitter at standing height (accuracy up to 1.5 cm and jitter <0.5 mm). The HTC Vive presented a larger working range (7 m) than did the Oculus Rift (4.25 m). Our results support the use of these devices for real navigation, exploration, exergaming, and motor rehabilitation in virtual reality environments.

  8. Feasibility and effectiveness of two community-based HIV testing models in rural Swaziland.

    PubMed

    Parker, Lucy Anne; Jobanputra, Kiran; Rusike, Lorraine; Mazibuko, Sikhathele; Okello, Velephi; Kerschberger, Bernhard; Jouquet, Guillaume; Cyr, Joanne; Teck, Roger

    2015-07-01

    To evaluate the feasibility (population reached, costs) and effectiveness (positivity rates, linkage to care) of two strategies of community-based HIV testing and counselling (HTC) in rural Swaziland. Strategies used were mobile HTC (MHTC) and home-based HTC (HBHTC). Information on age, sex, previous testing and HIV results was obtained from routine HTC records. A consecutive series of individuals testing HIV-positive were followed up for 6 months from the test date to assess linkage to care. A total of 9 060 people were tested: 2 034 through MHTC and 7 026 through HBHTC. A higher proportion of children and adolescents (<20 years) were tested through HBHTC than MHTC (57% vs. 17%; P < 0.001). MHTC reached a higher proportion of adult men than HBHTC (42% vs. 39%; P = 0.015). Of 398 HIV-positive individuals, only 135 (34%) were enrolled in HIV care within 6 months. Of 42 individuals eligible for antiretroviral therapy, 22 (52%) started treatment within 6 months. Linkage to care was lowest among people who had tested previously and those aged 20-40 years. HBHTC was 50% cheaper (US$11 per person tested; $797 per individual enrolled in HIV care) than MHTC ($24 and $1698, respectively). In this high HIV prevalence setting, a community-based testing programme achieved high uptake of testing and appears to be an effective and affordable way to encourage large numbers of people to learn their HIV status (particularly underserved populations such as men and young people). However, for community HTC to impact mortality and incidence, strategies need to be implemented to ensure people testing HIV-positive in the community are linked to HIV care. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  9. Age-Related Differences in Socio-demographic and Behavioral Determinants of HIV Testing and Counseling in HPTN 043/NIMH Project Accept.

    PubMed

    Salazar-Austin, N; Kulich, M; Chingono, A; Chariyalertsak, S; Srithanaviboonchai, K; Gray, G; Richter, L; van Rooyen, H; Morin, S; Sweat, M; Mbwambo, J; Szekeres, G; Coates, T; Celentano, D

    2018-02-01

    Youth represent a large proportion of new HIV infections worldwide, yet their utilization of HIV testing and counseling (HTC) remains low. Using the post-intervention, cross-sectional, population-based household survey done in 2011 as part of HPTN 043/NIMH Project Accept, a cluster-randomized trial of community mobilization and mobile HTC in South Africa (Soweto and KwaZulu Natal), Zimbabwe, Tanzania and Thailand, we evaluated age-related differences among socio-demographic and behavioral determinants of HTC in study participants by study arm, site, and gender. A multivariate logistic regression model was developed using complete individual data from 13,755 participants with recent HIV testing (prior 12 months) as the outcome. Youth (18-24 years) was not predictive of recent HTC, except for high-risk youth with multiple concurrent partners, who were less likely (aOR 0.75; 95% CI 0.61-0.92) to have recently been tested than youth reporting a single partner. Importantly, the intervention was successful in reaching men with site specific success ranging from aOR 1.27 (95% CI 1.05-1.53) in South Africa to aOR 2.30 in Thailand (95% CI 1.85-2.84). Finally, across a diverse range of settings, higher education (aOR 1.67; 95% CI 1.42, 1.96), higher socio-economic status (aOR 1.21; 95% CI 1.08-1.36), and marriage (aOR 1.55; 95% CI 1.37-1.75) were all predictive of recent HTC, which did not significantly vary across study arm, site, gender or age category (18-24 vs. 25-32 years).

  10. Role of male partner involvement in ART retention and adherence in Malawi's Option B+ program.

    PubMed

    Wesevich, Austin; Mtande, Tiwonge; Saidi, Friday; Cromwell, Elizabeth; Tweya, Hannock; Hosseinipour, Mina C; Hoffman, Irving; Miller, William C; Rosenberg, Nora E

    2017-11-01

    Malawi's Option B+ program provides all HIV-infected pregnant women free lifelong antiretroviral therapy (ART), but challenges remain regarding retention and ART adherence, potentially due to male partner barriers. We explored relationships between male partner involvement and Option B+ retention and adherence. In 2014, a randomized controlled trial in Malawi compared male recruitment strategies for couple HIV testing and counseling (cHTC) at an antenatal clinic. This secondary analysis was conducted among the entire cohort (N = 200) of women, irrespective of randomization status. We assessed whether cHTC attendance, early disclosure of HIV-positive status, and partner ART reminders were associated with retention and adherence at one month after starting treatment. Retention was defined as attending HIV clinic follow-up within one day of running out of pills. Adherence was defined as taking ≥95% of ARTs by pill count. We used binomial regression to calculate adjusted risk ratios (aRR) and 95% confidence intervals (CI). Median female age was 26 years. Most women (79%) were retained; of these, 68% were adherent. Receiving cHTC was associated with improved retention (aRR 1.33, 95% CI 1.12, 1.59). Receiving male partner ART reminders was weakly associated with retention (aRR 1.16, 95% CI 0.96, 1.39). Disclosure within one day was not associated with retention (aRR 1.08, 95% CI: 0.91, 1.28). Among those who were retained, these three behaviors were not associated with improved 95% adherence. CHTC could play an important role in improving Option B+ retention. Increasing cHTC participation and enhancing adherence-related messages within cHTC are important.

  11. Making a human right to tobacco control: expert and advocacy networks, framing and the right to health.

    PubMed

    Reubi, David

    2012-01-01

    This article addresses the proliferation of human rights in international public health over the last 20 years by examining recent attempts at framing the global smoking epidemic as a human rights problem. Rather than advocating in favour or against human rights-based approaches, the article purports to understand how and why such approaches are being articulated and disseminated. First, it argues that the representation of the global smoking epidemic as a human rights issue has been the product of a small, international network of public health experts and lawyers: the human rights and tobacco control collective or community (HTC). The article describes in particular the HTC's membership, its style of thinking and its efforts to articulate and disseminate human rights-based approaches to tobacco control. Second, the article argues that the aim of the HTC when framing tobacco control as a human rights issue was not to generate public attention for and the political will to tackle the global smoking epidemic, as the literature on framing and human rights presupposes. Instead, as the article shows, the HTC framed tobacco control as a human rights problem to tap into the powerful, judicial monitoring and enforceability mechanisms that make up international human rights.

  12. Process Design and Techno-economic Analysis for Materials to Treat Produced Waters.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heimer, Brandon Walter; Paap, Scott M; Sasan, Koroush

    Significant quantities of water are produced during enhanced oil recovery making these “produced water” streams attractive candidates for treatment and reuse. However, high concentrations of dissolved silica raise the propensity for fouling. In this paper, we report the design and economic analysis for a new ion exchange process using calcined hydrotalcite (HTC) to remove silica from water. This process improves upon known technologies by minimizing sludge product, reducing process fouling, and lowering energy use. Process modeling outputs included raw material requirements, energy use, and the minimum water treatment price (MWTP). Monte Carlo simulations quantified the impact of uncertainty and variabilitymore » in process inputs on MWTP. These analyses showed that cost can be significantly reduced if the HTC materials are optimized. Specifically, R&D improving HTC reusability, silica binding capacity, and raw material price can reduce MWTP by 40%, 13%, and 20%, respectively. Optimizing geographic deployment further improves cost competitiveness.« less

  13. Fate of Organic Micropollutants during Hydrothermal Carbonization

    NASA Astrophysics Data System (ADS)

    Weiner, B.; Baskyr, I.; Pörschmann, J.; Kopinke, F.-D.

    2012-04-01

    The hydrothermal carbonization (HTC) is an exothermic process, in which biomass in an aqueous suspension is transformed into a bituminous coal-like material (hydrochar) at temperatures between 180-250°C and under moderate pressure. With these process conditions, little gas is generated (1-5%), and a fraction of the organic carbon is dissolved in the aqueous phase (10-30%) but the largest part is obtained as solid char. The respective yields and the molecular composition depend on the choice of educts and the process conditions, such as temperature, pH-value, and reaction time. Various biomass-educts have recently been studied, such as waste materials from agriculture, brewer's spent grains, sewage sludge, as well as wood and paper materials. Besides their use for energy generation, the hydrochars have also been investigated as soil amendments. Prior to addition of the chars to soil, these should be free of toxic components that could be released into the environment as harmful organic pollutants. Herein, the potential for the degradation of trace organic pollutants, such as pesticides and pharmaceuticals, under typical HTC conditions will be presented. The degradation of selected organic pollutants with different polarity and hydrophobicity was investigated. Scope and limitations of the degradation potential of the HTC are discussed on examples of micro pollutants such as hormones, residues of pharmaceuticals and personal care products including their metabolites, and pesticides. We will show that the target analytes are partially and in some cases completely degraded. The degree of degradation depends on the HTC process conditions such as reaction temperature and time, the solution pH value, the presence of catalysts or additional reagents. The biotic and abiotic degradation of chlorinated organic compounds, in particular chlorinated aromatics, has been a well-known environmental problem and remains a challenging issue for the development of a HTC process for contaminated biomass. Chlorinated aromatic compounds are not fully degraded during HTC. Therefore, the addition of catalysts and reagents for a possible reduction has been studied. Zero-valent environmentally acceptable metals, such as Fe or Si, are presented as potential additives for the dechlorination of chloronaphthalene as a representative of chloroaromatics. Furthermore, when using municipal household waste, such as the 'organic' bin, or gardening greens as biomass educts, these materials often contain traces of synthetic plastics, which can lead to problems during waste incineration. Initial studies on the fate of synthetic polymers will also be presented.

  14. Perceived mHealth barriers and benefits for home-based HIV testing and counseling and other care: Qualitative findings from health officials, community health workers, and persons living with HIV in South Africa

    PubMed Central

    van Heerden, Alastair; Harris, Danielle M.; van Rooyen, Heidi; Barnabas, Ruanne V.; Ramanathan, Nithya; Ngcobo, Nkosinathi; Mpiyakhe, Zukiswa; Comulada, W. Scott

    2017-01-01

    mHealth has been proposed to address inefficiencies in the current South African healthcare system, including home-based HIV testing and counseling (HTC) programs. Yet wide-scale adoption of mHealth has not occurred. Even as infrastructure barriers decrease, a need to better understand perceived adoption barriers by stakeholders remains. We conducted focus group discussions (FGD) in South Africa in 2016 with 10 home-based HTC field staff, 12 community health workers (CHWs) and 10 persons living with HIV (PLH). Key informant (KI) interviews were conducted with five health officials. Perceptions about current home-based HTC practices, future mHealth systems and the use of biometrics for patient identification were discussed, recorded and transcribed for qualitative analysis. Themes were based on a conceptual model for perceived mHealth service quality. Stakeholders brought up a lack of communication in sharing patient health information between clinics, between clinics and CHWs, and between clinics and patients as major barriers to care that mHealth can address. CHWs need better patient information from clinics in terms of physical location and health status to plan visitation routes and address patient needs. CHWs perceive that communication barriers create distrust towards them by clinic staff. PLH want automated appointment and medication reminders. KI see mHealth as a way to improve health information transfer to government officials to better allocate healthcare resources. Stakeholders are also optimistic about the ability for biometrics to improve patient identification but disagreed as to which biometrics would be acceptable, especially in older patients. All stakeholders provided useful information towards the development of mHealth systems. Hospitals are adopting patient-centered approaches that solicit feedback from patients and incorporate them into decision-making processes. A similar approach is needed in the development of mHealth systems. Further, such systems are critical to the successful extension of the health system from health facilities into people’s homes. PMID:28475904

  15. Perceived mHealth barriers and benefits for home-based HIV testing and counseling and other care: Qualitative findings from health officials, community health workers, and persons living with HIV in South Africa.

    PubMed

    van Heerden, Alastair; Harris, Danielle M; van Rooyen, Heidi; Barnabas, Ruanne V; Ramanathan, Nithya; Ngcobo, Nkosinathi; Mpiyakhe, Zukiswa; Comulada, W Scott

    2017-06-01

    mHealth has been proposed to address inefficiencies in the current South African healthcare system, including home-based HIV testing and counseling (HTC) programs. Yet wide-scale adoption of mHealth has not occurred. Even as infrastructure barriers decrease, a need to better understand perceived adoption barriers by stakeholders remains. We conducted focus group discussions (FGD) in South Africa in 2016 with 10 home-based HTC field staff, 12 community health workers (CHWs) and 10 persons living with HIV (PLH). Key informant (KI) interviews were conducted with five health officials. Perceptions about current home-based HTC practices, future mHealth systems and the use of biometrics for patient identification were discussed, recorded and transcribed for qualitative analysis. Themes were based on a conceptual model for perceived mHealth service quality. Stakeholders brought up a lack of communication in sharing patient health information between clinics, between clinics and CHWs, and between clinics and patients as major barriers to care that mHealth can address. CHWs need better patient information from clinics in terms of physical location and health status to plan visitation routes and address patient needs. CHWs perceive that communication barriers create distrust towards them by clinic staff. PLH want automated appointment and medication reminders. KI see mHealth as a way to improve health information transfer to government officials to better allocate healthcare resources. Stakeholders are also optimistic about the ability for biometrics to improve patient identification but disagreed as to which biometrics would be acceptable, especially in older patients. All stakeholders provided useful information towards the development of mHealth systems. Hospitals are adopting patient-centered approaches that solicit feedback from patients and incorporate them into decision-making processes. A similar approach is needed in the development of mHealth systems. Further, such systems are critical to the successful extension of the health system from health facilities into people's homes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Accuracy and Precision of Position and Orientation Tracking in the HTC Vive Virtual Reality System for Scientific Research

    PubMed Central

    Niehorster, Diederick C.; Li, Li; Lappe, Markus

    2017-01-01

    The advent of inexpensive consumer virtual reality equipment enables many more researchers to study perception with naturally moving observers. One such system, the HTC Vive, offers a large field-of-view, high-resolution head mounted display together with a room-scale tracking system for less than a thousand U.S. dollars. If the position and orientation tracking of this system is of sufficient accuracy and precision, it could be suitable for much research that is currently done with far more expensive systems. Here we present a quantitative test of the HTC Vive’s position and orientation tracking as well as its end-to-end system latency. We report that while the precision of the Vive’s tracking measurements is high and its system latency (22 ms) is low, its position and orientation measurements are provided in a coordinate system that is tilted with respect to the physical ground plane. Because large changes in offset were found whenever tracking was briefly lost, it cannot be corrected for with a one-time calibration procedure. We conclude that the varying offset between the virtual and the physical tracking space makes the HTC Vive at present unsuitable for scientific experiments that require accurate visual stimulation of self-motion through a virtual world. It may however be suited for other experiments that do not have this requirement. PMID:28567271

  17. The Accuracy and Precision of Position and Orientation Tracking in the HTC Vive Virtual Reality System for Scientific Research.

    PubMed

    Niehorster, Diederick C; Li, Li; Lappe, Markus

    2017-01-01

    The advent of inexpensive consumer virtual reality equipment enables many more researchers to study perception with naturally moving observers. One such system, the HTC Vive, offers a large field-of-view, high-resolution head mounted display together with a room-scale tracking system for less than a thousand U.S. dollars. If the position and orientation tracking of this system is of sufficient accuracy and precision, it could be suitable for much research that is currently done with far more expensive systems. Here we present a quantitative test of the HTC Vive's position and orientation tracking as well as its end-to-end system latency. We report that while the precision of the Vive's tracking measurements is high and its system latency (22 ms) is low, its position and orientation measurements are provided in a coordinate system that is tilted with respect to the physical ground plane. Because large changes in offset were found whenever tracking was briefly lost, it cannot be corrected for with a one-time calibration procedure. We conclude that the varying offset between the virtual and the physical tracking space makes the HTC Vive at present unsuitable for scientific experiments that require accurate visual stimulation of self-motion through a virtual world. It may however be suited for other experiments that do not have this requirement.

  18. APT Blanket Thermal Analyses of Top Horizontal Row 1 Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shadday, M.A.

    1999-09-20

    The Accelerator Production of Tritium (APT) cavity flood system (CFS) is designed to be the primary safeguard for the integrity of the blanket modules during loss of coolant accidents (LOCAs). For certain large break LOCAs the CFS also provides backup for the residual heat removal systems (RHRs) in cooling the target assemblies. In the unlikely event that the internal flow passages in a blanket module or target assembly dryout, decay heat in the metal structures will be dissipated to the CFS through the module or assembly walls (i.e., rung outer walls). The target assemblies consist of tungsten targets encased inmore » steel conduits, and they can safely sustain high metal temperatures. Under internally dry conditions, the cavity flood fluid will cool the target assemblies with vigorous nucleate boiling on the external surfaces. However, the metal structures in the blanket modules consist of lead cladded in aluminum, and they have a long-term exposure temperature limit currently set to 150 degrees C. Simultaneous LOCAs in both the target and blanket heat removal systems (HRS) could result in dryout of the target ladders, as well as the horizontal blanket modules above the target. The cavity flood coolant would boil on the outside surfaces of the target ladder rungs, and the resultant steam could reduce the effectiveness of convection heat transfer from the blanket modules to the cavity flood coolant. A two-part analysis was conducted to ascertain if the cavity flood system can adequately cool the blanket modules above the targets, even when boiling is occurring on the outer surfaces of the target ladder rungs. The first part of the analysis was to model transient thermal conduction in the front top horizontal row 1 module (i.e. top horizontal modules nearest the incoming beam), while varying parametrically the convection heat transfer coefficient (htc) for the external surfaces exposed to the cavity flood flow. This part of the analysis demonstrated that the module could adequately conduct heat to the outer module surfaces, given reasonable values for the convection heat transfer coefficients. The second part of the analysis consisted of two-phase flow modeling of the natural circulation of the cavity flood fluid past the top modules. Slots in the top shield allow the cavity flood fluid to circulate. The required width for these slots, to prevent steam from backing up and blanketing the outer surfaces of the top modules, was determined.« less

  19. Grassroots community organizations' contribution to the scale-up of HIV testing and counselling services in Zimbabwe.

    PubMed

    Gregson, Simon; Nyamukapa, Constance A; Sherr, Lorraine; Mugurungi, Owen; Campbell, Catherine

    2013-06-19

    To investigate whether community engagement (participation in grassroots organizations) contributed to increases in HIV testing in Zimbabwe. Prospective data on membership of local community organizations (e.g. women's groups and burial societies) and uptake of HIV testing and counselling (HTC) and prevention-of-mother-to-child transmission (PMTCT) services were collected from 5260 adults interviewed in two consecutive rounds of a general-population cohort survey in eastern Zimbabwe between 2003 and 2008. The effects of community engagement on uptake of services during the follow-up period were measured using logistic regression to adjust for observed confounding factors. Sixteen percent of men and 47% of women were consistent members of community organizations; 58 and 35% of these people discussed HIV in their meetings and were members of externally sponsored organizations, respectively. Fewer men (10.1%) than women (32.4%) took up HTC during follow-up [adjusted odds ratio (aOR)=4.08, 95% confidence interval (CI) 3.43-4.86, P<0.001]. HTC uptake was higher for members of community organizations than for nonmembers: men, 15.0 versus 9.2% (1.67, 1.15-2.43, P=0.007); women, 35.6 versus 29.6% (1.26, 1.06-1.49, P=0.008). Membership of community organizations showed a nonsignificant association with PMTCT uptake amongst recently pregnant women (42.3 versus 34.2%; 1.30, 0.94-1.78, P=0.1). The most consistent positive associations between community participation and HTC and PMTCT uptake were found in organizations that discussed HIV and when external sponsorship was absent. Grassroots organizations contributed to increased uptake of HTC services in eastern Zimbabwe in the mid-2000s. Partnerships with these organizations could harness community support for the further increases in HIV testing needed in sub-Saharan Africa. © 2013 Creative Common License

  20. Grassroots community organizations’ contribution to the scale-up of HIV testing and counselling services in Zimbabwe

    PubMed Central

    Gregson, Simon; Nyamukapa, Constance A.; Sherr, Lorraine; Mugurungi, Owen; Campbell, Catherine

    2013-01-01

    Objective: To investigate whether community engagement (participation in grassroots organizations) contributed to increases in HIV testing in Zimbabwe. Methods: Prospective data on membership of local community organizations (e.g. women's groups and burial societies) and uptake of HIV testing and counselling (HTC) and prevention-of-mother-to-child transmission (PMTCT) services were collected from 5260 adults interviewed in two consecutive rounds of a general-population cohort survey in eastern Zimbabwe between 2003 and 2008. The effects of community engagement on uptake of services during the follow-up period were measured using logistic regression to adjust for observed confounding factors. Results: Sixteen percent of men and 47% of women were consistent members of community organizations; 58 and 35% of these people discussed HIV in their meetings and were members of externally sponsored organizations, respectively. Fewer men (10.1%) than women (32.4%) took up HTC during follow-up [adjusted odds ratio (aOR) = 4.08, 95% confidence interval (CI) 3.43–4.86, P < 0.001]. HTC uptake was higher for members of community organizations than for nonmembers: men, 15.0 versus 9.2% (1.67, 1.15–2.43, P = 0.007); women, 35.6 versus 29.6% (1.26, 1.06–1.49, P = 0.008). Membership of community organizations showed a nonsignificant association with PMTCT uptake amongst recently pregnant women (42.3 versus 34.2%; 1.30, 0.94–1.78, P = 0.1). The most consistent positive associations between community participation and HTC and PMTCT uptake were found in organizations that discussed HIV and when external sponsorship was absent. Conclusion: Grassroots organizations contributed to increased uptake of HTC services in eastern Zimbabwe in the mid-2000s. Partnerships with these organizations could harness community support for the further increases in HIV testing needed in sub-Saharan Africa. PMID:24047764

  1. Effects of Tai Chi exercise on blood pressure and plasma levels of nitric oxide, carbon monoxide and hydrogen sulfide in real-world patients with essential hypertension.

    PubMed

    Pan, Xiaogui; Zhang, Yi; Tao, Sai

    2015-01-01

    Objective was to investigate the effects of Tai Chi exercise on nitric oxide (NO), carbon monoxide (CO) and hydrogen sulfide (H2S) levels, and blood pressure (BP) in patients with essential hypertension (EH). EH patients were assigned to the Tai Chi exercise group (HTC, n = 24), and hypertension group (HP, n = 16) by patients' willingness. Healthy volunteers matched for age and gender were recruited as control (NP, n = 16). HTC group performed Tai Chi (60 min/d, 6 d/week) for 12 weeks. Measurements (blood glucose, cholesterol, NO, CO, H2S and BP) were obtained at week 0, 6, and 12. SBP, MAP, and low-density lipoprotein cholesterol levels decreased, and high-density lipoprotein cholesterol levels increased by week 12 in the HTC group (all p < 0.05 versus baseline). Plasma NO, CO, and H2S levels in the HTC group were increased after 12 weeks (all p < 0.05 versus baseline). SBP, DBP and MAP levels were significantly lower in the HTC than in the HP group (all p < 0.05). However, no changes were observed in the HP and NP groups. Correlations were observed between changes in SBP and changes in NO, CO and H2S (r = -0.45, -0.51 and -0.46, respectively, all p < 0.05), and between changes in MAP and changes in NO, CO and H2S (r = -0.36, -0.45 and -0.42, respectively, all p < 0.05). In conclusion, Tai Chi exercise seems to have beneficial effects on BP and gaseous signaling molecules in EH patients. However, further investigation is required to understand the exact mechanisms underlying these observations, and to confirm these results in a larger cohort.

  2. Establishment of Hydrographic Shore Control by Doppler Satellite Techniques.

    DTIC Science & Technology

    1984-06-01

    entered in 8116,h 20. if different tromn Report) 10.SPAccuNTRaY NSdrs AHOacurcystndrd, raslcaio, IS. AEY WRDC (Continue en roer@e side it necessary And...the Defense Mapping Agency, Hydrographic-Topographlc Center (DMA-HTC); the ephemerides are computed and distributed by the DMA-HTC [Ref. 3J. The...all,_ C: En m zz E-4~E- 0 .4 0 = 0 z 4 .4 z 4 c -4 4 1 0j 0 heU 7 60 VIII. ACCURACY STANDARDS AND SPECIFICATIONS A. CURRENT ACCURACY

  3. Efficiency gain limits of the parallel segmented inlet and outlet flow concept in analytical liquid chromatography columns suffering from radial transcolumn packing density gradients.

    PubMed

    Broeckhoven, Ken; Desmet, Gert

    2012-10-05

    The maximal gain in efficiency that can be expected from the use of the segmented column end fittings that were recently introduced to alleviate the effect of transcolumn packing density gradients has been quantified and generalized using numerical computations of the band broadening process. It was found that, for an unretained compound in a column with a parabolic packing density gradient, the use of a segmented inlet or a segmented outlet allows to eliminate about 60-100% of the plate height contribution (H(tc)) originating from a parabolic transcolumn velocity gradient in a d(c)=4.6 mm column. In a d(c)=2.1 mm column, these percentages change from 10 to 100%. Using a combined segmented in- and outlet, H(tc) can be reduced by about 90-100% (d(c)=4.6 mm column) or 20-100% (d(c)=2.1 mm column). The strong variation of these gain percentages is due to fact that they depend very strongly on the column length and the flow rate. Dimensionless graphs have been established that allow to directly quantify the effect for each specific case. It was also found that, in agreement with one's physical intuition, trans-column velocity profiles that are more flat in the central region benefit more from the concept than sharp, parabolic-like profiles. The gain margins furthermore tend to become smaller with increasing retention and increasing diffusion coefficient. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Symbiotic relationship between hydrothermal carbonization technology and anaerobic digestion for food waste in China.

    PubMed

    Zhou, Ying; Engler, Nils; Nelles, Michael

    2018-07-01

    Food waste (FW) is traditionally disposed through landfills and incineration in China. Nowadays, there are some promising methods, such as anaerobic digestion (AD) or feeding and composting, which are being applied in pilot cities. However, the inherent characteristics of Chinese FW may be regarded as a double-edged sword in the practical applications of these disposal methods. To overcome these challenges, two modes of the hydrothermal carbonization (HTC) process were reviewed as innovative strategies in this article. Meanwhile, the "symbiotic relationship" between Chinese FW and HTC technologies was highlighted. To improve treatment efficiency of FW, we should not only try different methods and develop existing technologies, but also pay more attention to the utilization and "1 + 1 > 2" synergistic effect of their combinations, such as the combination of HTC and AD as a co-treatment method for saving on the construction cost and avoiding redistribution of social resources. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Recovery of Macro and Micro-Nutrients by Hydrothermal Carbonization of Septage.

    PubMed

    McGaughy, Kyle; Reza, M Toufiq

    2018-02-28

    In this study, septic tank waste (i.e., septage) was hydrothermally carbonized (HTC) in order to recover macro and micronutrients, while tracking the fate of residual heavy metals. Three different HTC temperatures (i.e., 180, 220, and 260 °C) at autogenous pressures and two reaction times (i.e., 30 and 120 min) were applied on both solid and liquid septages. Hydrochar and HTC process liquids were characterized using ICP, CHNS, and UV-vis spectroscopy. Treatment at 260 °C for 120 min maximized ammonia recovery, producing a liquid with 1400 mg/L of ammonia. Overall, about 70% of available nitrogen ended up in the liquid phase as nitrate or ammonia. Solid hydrochars show potential for fertilizer use, with high phosphorus content of 100-130 kg/tonne. It was found that heavy metals mainly remained in the solid phase, although the concentrations of heavy metals are mostly lower than U.S. EPA regulation for biosolids with the exception of selenium.

  6. Recent HIV Testing Among Young Men Who Have Sex with Men in Bangkok and Chiang Mai: HIV Testing and Prevention Strategies Must Be Enhanced in Thailand.

    PubMed

    Johnston, Lisa G; Steinhaus, Mara C; Sass, Justine; Sirinirund, Petchsri; Lee, Catherine; Benjarattanaporn, Patchara; Gass, Robert

    2016-09-01

    HIV infection among men who have sex with men, particularly in Thai urban settings and among younger cohorts, is escalating. HIV testing and counseling (HTC) are important for prevention and obtaining treatment and care. We examine data from a 2013 survey of males, 15-24 years, reporting past-year sex with a male and living in Bangkok or Chiang Mai. Almost three quarters of young MSM (YMSM) in Bangkok and only 27 % in Chiang Mai had an HIV test in the previous year. Associations for HIV testing varied between cities, although having employment increased the odds of HIV testing for both cities. In Bangkok, family knowledge of same sex attraction and talking to parents/guardians about HIV/AIDS had higher odds of HIV testing. Expanded HTC coverage is needed for YMSM in Chiang Mai. All health centers providing HTC, including those targeting MSM, need to address the specific needs of younger cohorts.

  7. Upgrading agricultural wastes using three different carbonization methods: Thermal, hydrothermal and vapothermal.

    PubMed

    Yeoh, Keat-Hor; Shafie, S A; Al-Attab, K A; Zainal, Z A

    2018-06-15

    In this study, three different methods for high quality solid fuel production were tested and compared experimentally. Oil palm empty fruit bunches, mesocarp fibers, palm kernel shells and rubber seeds shells were treated using thermal (TC), hydrothermal (HTC) and vapothermal (VTC) carbonization. All thermochemical methods were accomplished by using a custom made batch-type reactor. Utilization of novel single reactor equipped with suspended internal container provided efficient operation since both steam generator and raw materials were placed inside the same reactor. Highest energy densification was achieved by VTC process followed by TC and HTC processes. The heating value enhancement in VTC and TC was achieved by the increase in fixed carbon content and reduction in volatile matter. The formation of the spherical components in HTC hydrochar which gave a sharp peak at 340 °C in the DTG curves was suggested as the reason that led to the increment in energy content. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Effect of hydrothermal carbonization on migration and environmental risk of heavy metals in sewage sludge during pyrolysis.

    PubMed

    Liu, Tingting; Liu, Zhengang; Zheng, Qingfu; Lang, Qianqian; Xia, Yu; Peng, Nana; Gai, Chao

    2018-01-01

    The heavy metals distribution during hydrothermal carbonization (HTC) of sewage sludge, and pyrolysis of the resultant hydrochar was investigated and compared with raw sludge pyrolysis. The results showed that HTC reduced exchangeable/acid-soluble and reducible fraction of heavy metals and lowered the potential risk of heavy metals in sewage sludge. The pyrolysis favored the transformation of extracted/mobile fraction of heavy metals to residual form especially at high temperature, immobilizing heavy metals in the chars. Compared to the chars from raw sludge pyrolysis, the chars derived from hydrochar pyrolysis was more alkaline and had lower risk and less leachable heavy metals, indicating that pyrolysis imposed more positive effect on immobilization of heavy metals for the hydrochar than for sewage sludge. The present study demonstrated that HTC is a promising pretreatment prior to pyrolysis from the perspective of immobilization of heavy metals in sewage sludge. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. [Therapeutic effect of early applying hydrotherapy with Chinese drugs on children hypoxic ischemic encephalopathy].

    PubMed

    Ma, Yun-Zhi; Zhai, Hong-Yin; Su, Chun-Ya

    2009-02-01

    To observe the therapeutic effect of hydrotherapy with Chinese drugs (HT-C) in early intervention on children hypoxic ischemic encephalopathy (HIE). HIE children were assigned to the treatment group and the control group, 50 in each, at random depending on the willingness of patients' parents. Both groups received the conventional functional training, according to the "0 -3-year-old early intervention outline", but for the treatment group, HT-C was applied additionally. Indexes for quality of sleep, gross motor function, severity of spasm and intellectual development were observed and compared before and after treatment to assess the therapeutic effects. Therapeutic effect in the treatment group was better than that in the control group in all the indexes observed, showing statistical significance (all P <0.05). Early intervention of HT-C could improve clinical symptom, promote the functional recovery and intellectual development in children HIE, and also could reduce or prevent the sequelae occurrence of the nervous system in them.

  10. The Status of HIV Testing and Counseling in Kenya: Results From a Nationally Representative Population-Based Survey

    PubMed Central

    Ng’ang’a, Anne; Waruiru, Wanjiru; Ngare, Carol; Ssempijja, Victor; Gachuki, Thomas; Njoroge, Inviolata; Oluoch, Patricia; Kimanga, Davies O.; Maina, William K.; Mpazanje, Rex; Kim, Andrea A.

    2016-01-01

    Background HIV testing and counseling (HTC) is essential for successful HIV prevention and treatment programs. The national target for HTC is 80% of the adult population in Kenya. Population-based data to measure progress towards this HTC target are needed to assess the country’s changing needs for HIV prevention and treatment. Methods In 2012–2013, we conducted a national HIV survey among Kenyans aged 18 months to 64 years. Respondents aged 15–64 years were administered a questionnaire that collected information on demographics, HIV testing behavior, and self-reported HIV status. Blood samples were collected for HIV testing in a central laboratory. Participants were offered home-based testing and counseling to learn their HIV status in the home and point-of-care CD4 testing if they tested HIV-positive. Results Of 13,720 adults who were interviewed, 71.6% [95% confidence interval (CI): 70.2 to 73.1] had been tested for HIV. Among those, 56.1% (95% CI: 52.8 to 59.4) had been tested in the past year, 69.4% (95% CI: 68.0 to 70.8) had been tested more than once, and 37.2% (95% CI: 35.7 to 38.8) had been tested with a partner. Fifty-three percent (95% CI: 47.6 to 58.7) of HIV-infected persons were unaware of their infection. Overall 9874 (72.0%) of participants accepted home-based HIV testing and counseling; 4.1% (95% CI: 3.3 to 4.9) tested HIV-positive, and of those, 42.5% (95% CI 31.4 to 53.6) were in need of immediate treatment for their HIV infection but not receiving it. Conclusions HIV testing rates have nearly reached the national target for HTC in Kenya. However, knowledge of HIV status among HIV-infected persons remains low. HTC needs to be expanded to reach more men and couples, and strategies are needed to increase repeat testing for persons at risk for HIV infection. PMID:24732818

  11. What is the cost of providing outpatient HIV counseling and testing and antiretroviral therapy services in selected public health facilities in Nigeria?

    PubMed

    Aliyu, Husaina Bello; Chuku, Nkata Nwani; Kola-Jebutu, Abimbola; Abubakar, Zubaida; Torpey, Kwasi; Chabikuli, Otto Nzapfurundi

    2012-10-01

    Limited data on actual cost of providing HIV/AIDS services in Nigeria makes planning difficult. A study was conducted in 9 public health facilities supported by the Global HIV/AIDS Initiative Nigeria. The objective was to determine the cost of outpatient HIV Testing and Counseling (HTC) and antiretroviral therapy (ART) services per patient. Two tertiary and 7 secondary facilities were purposively selected across the six geopolitical regions. Facilities were distributed in urban and rural settings. Utilization and cost data for a 12-month period (January to December 2010) were analyzed. Cost elements included consumables, human resources, infrastructure, trainings, facility management, and Global HIV/AIDS Initiative Nigeria technical support. Total costs were apportioned based on percentage utilization by services, and unit costs were derived by dividing resource inputs by service outputs. Data were analyzed using Microsoft Excel 2003. A sensitivity analysis was also conducted for key assumptions. Mean costs for HTC and ART were US $7.4 and US $209.0, respectively. Costs were higher in Northern facilities (US $6.9, US $250.8), compared with Southern ones (US $6.7, US $194.7); and in tertiary facilities ($18.5, $338.4), compared with secondary ones ($6.3, $204.9). Major cost drivers for HTC and ART were human resources--ranging from 62% to 50%, and ARV drugs--ranging from 54% to 31%, respectively. Governments' ability to negotiate lower priced antiretroviral drugs will be central to reducing the cost of ART. Additionally, use of lower cadre staff to provide HTC will reduce costs and improves efficiency.

  12. Development and validation of an universal interface for compound-specific stable isotope analysis of chlorine (37Cl/35Cl) by GC-high-temperature conversion (HTC)-MS/IRMS.

    PubMed

    Renpenning, Julian; Hitzfeld, Kristina L; Gilevska, Tetyana; Nijenhuis, Ivonne; Gehre, Matthias; Richnow, Hans-Hermann

    2015-03-03

    A universal application of compound-specific isotope analysis of chlorine was thus far limited by the availability of suitable analysis techniques. In this study, gas chromatography in combination with a high-temperature conversion interface (GC-HTC), converting organic chlorine in the presence of H2 to gaseous HCl, was coupled to a dual-detection system, combining an ion trap mass spectrometer (MS) and isotope-ratio mass spectrometer (IRMS). The combination of the MS/IRMS detection enabled a detailed characterization, optimization, and online monitoring of the high-temperature conversion process via ion trap MS as well as a simultaneous chlorine isotope analysis by the IRMS. Using GC-HTC-MS/IRMS, chlorine isotope analysis at optimized conversion conditions resulted in very accurate isotope values (δ(37)Cl(SMOC)) for measured reference material with known isotope composition, including chlorinated ethylene, chloromethane, hexachlorocyclohexane, and trichloroacetic acids methyl ester. Respective detection limits were determined to be <15 nmol Cl on column with achieved precision of <0.3‰.

  13. Polymorphisms in the bovine HSP90AB1 gene are associated with heat tolerance in Thai indigenous cattle.

    PubMed

    Charoensook, Rangsun; Gatphayak, Kesinee; Sharifi, Ahmad Reza; Chaisongkram, Chavin; Brenig, Bertram; Knorr, Christoph

    2012-04-01

    Heat shock proteins act as molecular chaperones that have preferentially been transcribed in response to severe perturbations of the cellular homeostasis such as heat stress. Here the traits respiration rate (RR), rectal temperature (RT), pack cell volume (PCV) and the individual heat tolerance coefficient (HTC) were recorded as physiological responses on heat stress (environmental temperatures) in Bos taurus (crossbred Holstein Friesian; HF) and B. indicus (Thai native cattle: White Lamphun; WL and Mountain cattle; MT) animals (n = 47) in Thailand. Polymorphisms of the heat shock protein 90-kDa beta gene (HSP90AB1) were evaluated by comparative sequencing. Nine single nucleotide polymorphisms (SNP) were identified, i.e. three in exons 10 and 11, five in introns 8, 9, 10 and 11, and one in the 3'UTR. The exon 11 SNP g.5082C>T led to a missense mutation (alanine to valine). During the period of extreme heat (in the afternoon) RR and RT were elevated in each of the three breeds, whereas the PCV decreased. Mountain cattle and White Lamphun heifers recorded significantly better physiologic parameters (p < 0.05) in all traits considered, including or particularly HTC than Holstein Friesian heifers. The association analysis revealed that the T allele at SNP g.4338T>C within intron 3 improved the heat tolerance (p < 0.05). Allele T was exclusively found in White Lamphun animals and to 84% in Mountain cattle. Holstein Friesian heifers revealed an allele frequency of only 18%. Polymorphisms within HSP90AB1 were not causative for the physiological responses; however, we propose that they should at least be used as genetic markers to select appropriate breeds for hot climates.

  14. Effect of various refining processes for Kenaf Bast non-wood pulp fibers suspensions on heat transfer coefficient in circular pipe heat exchanger

    NASA Astrophysics Data System (ADS)

    Ahmed, Syed Muzamil; Kazi, S. N.; Khan, Ghulamullah; Sadri, Rad; Dahari, Mahidzal; Zubir, M. N. M.; Sayuti, M.; Ahmad, Pervaiz; Ibrahim, Rushdan

    2018-03-01

    Heat transfer coefficients were obtained for a range of non-wood kenaf bast pulp fiber suspensions flowing through a circular pipe heat exchanger test loop. The data were produced over a selected temperature and range of flow rates from the flow loop. It was found that the magnitude of the heat transfer coefficient of a fiber suspension is dependent on characteristics, concentration and pulping method of fiber. It was observed that at low concentration and high flow rates, the heat transfer coefficient values of suspensions were observed higher than that of the heat transfer coefficient values of water, on the other hand the heat transfer coefficient values of suspensions decreases at low flow rates and with the increase of their concentration. The heat transfer were affected by varying fiber characteristics, such as fiber length, fiber flexibility, fiber chemical and mechanical treatment as well as different pulping methods used to liberate the fibers. Heat transfer coefficient was decreased with the increase of fiber flexibility which was also observed by previous researchers. In the present work, the characteristics of fibers are correlated with the heat transfer coefficient of suspensions of the fibers. Deviations in fiber properties can be monitored from the flowing fiber suspensions by measuring heat transfer coefficient to adjust the degree of fiber refining treatment so that papers made from those fibers will be more uniform, consistent, within the product specification and retard the paper production loss.

  15. Removal of Contaminant Nanoparticles from Wastewater Produced Via Hydrothermal Carbonization by SPIONs

    NASA Astrophysics Data System (ADS)

    Parsapour, Melika

    Hydrothermal carbonization (HTC) is a chemical approach that can be defined as a combined dehydration and decarboxylation process in a wet state. Briefly, this process is performed by applying elevated temperature (between 180-250°C) and pressure (around 2MPa) to convert biomass from aqueous suspension (e.g. sludge, wastewater, natural products, among other) into three different phases and materials products, including biocoal. Further, during the wet conversion process the high residue content is transformed into nanoparticles that could present well-defined or heterogeneous nanostructure. Although HTC was known for years, it has been focused only recently due to exclusive products properties and cost-effective production. In fact, HTC has been used for sludge and wastewater treatment plants in some developed countries such as Germany. Nowadays, many scientific groups still investigate solid products (e.g. biocoal) from HTC. These studies are related to physico-chemical and biological characterization of HTC's generated materials, as well as their potential uses. However, aqueous products from HTC, which are rich in hydrocarbons derivatives and nanoparticles (NPs), are rarely studied. Thereby, our objective is to study the wastewater generated from HTC applied to samples of either glycerin or sugar. Furthermore, we propose a novel treatment strategy to remove the NPs from the wastewater. In this regard, we have used Superparamagnetic Iron Oxide (SPIONs) due to their unique physico-chemical properties (magnetic properties, adsorption capacity, biocompatibility and eco-friendly degradation) for decontamination of water and wastewater. In this regard, we synthesized two different nanocomposites based on SPIONs to carry out the magnetic removal of existent NPs in the wastewater. For the first case, we synthesized polyethylene-glycol (PEG) coated SPIONS (SPIONs PEG). The second one was a new nanocomposite (SPIONs/GO) obtained from in situ growth of SPIONS over purified graphene oxide (GO), which was afterwards coated with PEG (20000Da), resulting in SPIONs/GO PEG. As GO has various functional groups that have a high valence for absorption of contaminants due to their oxygen content, we assume that SPIONs/GO PEG improves the efficiency of the decontamination process compared to SPIONs PEG alone. Initially, we have characterized the synthetized SPIONs. Fourier Transform Infrared spectroscopy (FT-IR) was used to identify the present functional groups in the SPIONs samples. Atomic Force Microscopy (AFM) and Transmission Electronic Microscopy (TEM) were used to determine the topography and diameter size via high resolution images with fine details of the nanocomposites. Finally Dynamic Light Scattering (DLS) was used to evaluate the size distribution of the SPIONs in distilled water. Also, all wastewater samples were characterized before and after treatment. FT-IR was used to determine the functional groups in initial samples. Ultraviolet-visible spectroscopy (UV-vis) was used to observe the UV absorption of the chemicals. DLS was used for size distribution and density measurement, and morphology investigation was done by AFM technique. The SPIONs which involved the GO due to the presence of oxidizes groups showed a better ordered crystalline structure and a narrower diameter distribution. The glycerin samples treated by SPIONs PEG and SPIONs/GO PEG demonstrated 43% and 38% reduction in contaminant respectively. As for the sugar samples, the reductions were of 33% and 60% respectively. Thus, the obtained results confirm the capability of the nanocomposites to remove the nano contaminant from wastewater samples reasonably. However, the decontamination power of the nanocomposites differs accordingly to the chemical structure of the initial biomass.

  16. Innovative strategies using communications technologies to engage gay men and other men who have sex with men into early HIV testing and treatment in Thailand.

    PubMed

    Anand, Tarandeep; Nitpolprasert, Chattiya; Ananworanich, Jintanat; Pakam, Charnwit; Nonenoy, Siriporn; Jantarapakde, Jureeporn; Sohn, Annette H; Phanuphak, Praphan; Phanuphak, Nittaya

    2015-04-01

    One-in-three men who have sex with men (MSM) surveyed between 2007 and 2010 in Bangkok were HIV infected; 54% of new infections in Thailand are expected to be among MSM. Although MSM are the top internet-accessing population in Thailand, it has not been optimally used to scale up early HIV testing and counselling (HTC) and linkage to treatment. Thailand needs innovative technology-based strategies to help address the exploding epidemic of HIV among gay men and other MSM. Adam's Love, an innovative web-based communications strategy, was launched in 2011 by the Thai Red Cross AIDS Research Centre. It includes a dedicated website, integrated social media and web message boards for online counselling, recruitment and appointment making, a club membership programme offering non-financial incentives for HTC, targeted marketing and promotions, and collaboration with MSM-friendly clinics and private hospitals to improve accessibility of HTC services. Between September 2011 and January 2015, the website engaged 1.69 million viewers, and gained more than 8 million page views. An estimated 11,120 gay men and other MSM received online counselling; 8,288 MSM were referred to HTC services; 1,223 to STI testing services; and 1,112 MSM living with HIV were advised regarding HIV treatment. In total, 1,181 MSM recruited online were enrolled in the club membership programme, and 15.5% were diagnosed with HIV. The Adam's Love programme has successfully demonstrated the potential for utilising 'online-to-offline' recruitment models in Thailand, and has attracted national and regional recognition as a trusted resource on HIV and referral to testing and care.

  17. Different responses of vanillic acid, a phenolic compound, in HTC cells: cytotoxicity, antiproliferative activity, and protection from DNA-induced damage.

    PubMed

    Almeida, I V; Cavalcante, F M L; Vicentini, V E P

    2016-12-19

    The consumption of healthy and natural foods has increased over the last few years, primarily because these foods are rich in substances with biological properties of interest, such as exerting anticancer effects and decreasing oxidative stress in living tissues. These foods support adequate nutrition, maintain health, and improve quality of life. Vanillic acid (VA) is a phenolic compound used widely in the food industry as a flavoring, preservative, and food additive. VA can be found in various cereals, whole grains, fruits, herbs, green tea, juices, beers, and wines and possesses antioxidant, hepatoprotective, cardioprotective, and antiapoptotic activities. Studying the cytotoxicity as well as the mutagenic and antimutagenic effects of different concentrations of VA in Rattus norvegicus hepatoma cells (HTC) can identify new cellular activities of this substance. Concentrations up to 100 µM VA are not cytotoxic to HTC cells in a MTT [3-(4,5-dimethilthiazol-2-yl)-2,5-diphenil tetrazolium bromide] assay after 96-h exposure; therefore, VA does not compromise mitochondrial activity. Similarly, concentrations up to 500 µM do not compromise plasma membrane integrity. VA at 10 and 50 µM showed no mutagenic/clastogenic effects, as no significant micronuclei induction was observed. VA 10 µM presented no antiproliferative activity and reduced the cytotoxicity induced by benzo[a]pyrene. The antimutagenic activity of 10 µM VA was observed by the simultaneous, pre-, and post-treatments, as the phenolic compound significantly reduced the frequency of micronuclei induced by the mutagen. These results indicate that VA exerts different responses in HTC cells. Low concentrations present no cytotoxic, mutagenic, or antiproliferative effects and protect cells from DNA damage.

  18. Effects of an HIV peer prevention intervention on sexual and injecting risk behaviors among injecting drug users and their risk partners in Thai Nguyen, Vietnam: A randomized controlled trial

    PubMed Central

    Go, Vivian F.; Frangakis, Constantine; Le Minh, Nguyen; Latkin, Carl A.; Ha, Tran Viet; Mo, Tran Thi; Sripaipan, Teerada; Davis, Wendy; Zelaya, Carla; Vu, Pham The; Chen, Yong; Celentano, David D.; Quan, Vu Minh

    2014-01-01

    Globally, 30% of new HIV infections outside sub-Saharan Africa involve injecting drug users (IDU) and in many countries, including Vietnam, HIV epidemics are concentrated among IDU. We conducted a randomized controlled trial in Thai Nguyen, Vietnam, to evaluate whether a peer oriented behavioral intervention could reduce injecting and sexual HIV risk behaviors among IDU and their network members. 419 HIV-negative index IDU aged 18 years or older and 516 injecting and sexual network members were enrolled. Each index participant was randomly assigned to receive a series of six small group peer educator-training sessions and three booster sessions in addition to HIV testing and counseling (HTC) (intervention; n = 210) or HTC only (control; n = 209). Follow-up, including HTC, was conducted at 3, 6, 9 and 12 months post-intervention. The proportion of unprotected sex dropped significantly from 49% to 27% (SE (difference) = 3%, p < 0.01) between baseline and the 3-month visit among all index-network member pairs. However, at 12 months, post-intervention, intervention participants had a 14% greater decline in unprotected sex relative to control participants (Wald test = 10.8, df = 4, p = 0.03). This intervention effect is explained by trial participants assigned to the control arm who missed at least one standardized HTC session during follow-up and subsequently reported increased unprotected sex. The proportion of observed needle/syringe sharing dropped significantly between baseline and the 3-month visit (14% vs. 3%, SE (difference) = 2%, p < 0.01) and persisted until 12 months, but there was no difference across trial arms (Wald test = 3.74, df = 3, p = 0.44). PMID:24034963

  19. Costs along the service cascades for HIV testing and counselling and prevention of mother-to-child transmission

    PubMed Central

    Bautista-Arredondo, Sergio; Sosa-Rubí, Sandra G.; Opuni, Marjorie; Contreras-Loya, David; Kwan, Ada; Chaumont, Claire; Chompolola, Abson; Condo, Jeanine; Galárraga, Omar; Martinson, Neil; Masiye, Felix; Nsanzimana, Sabin; Ochoa-Moreno, Ivan; Wamai, Richard; Wang’ombe, Joseph

    2016-01-01

    Objective: We estimate facility-level average annual costs per client along the HIV testing and counselling (HTC) and prevention of mother-to-child transmission (PMTCT) service cascades. Design: Data collected covered the period 2011–2012 in 230 HTC and 212 PMTCT facilities in Kenya, Rwanda, South Africa, and Zambia. Methods: Input quantities and unit prices were collected, as were output data. Annual economic costs were estimated from the service providers’ perspective using micro-costing. Average annual costs per client in 2013 United States dollars (US$) were estimated along the service cascades. Results: For HTC, average cost per client tested ranged from US$5 (SD US$7) in Rwanda to US$31 (SD US$24) in South Africa, whereas average cost per client diagnosed as HIV-positive ranged from US$122 (SD US$119) in Zambia to US$1367 (SD US$2093) in Rwanda. For PMTCT, average cost per client tested ranged from US$18 (SD US$20) in Rwanda to US$89 (SD US$56) in South Africa; average cost per client diagnosed as HIV-positive ranged from US$567 (SD US$417) in Zambia to US$2021 (SD US$3210) in Rwanda; average cost per client on antiretroviral prophylaxis ranged from US$704 (SD US$610) in South Africa to US$2314 (SD US$3204) in Rwanda; and average cost per infant on nevirapine ranged from US$888 (SD US$884) in South Africa to US$2359 (SD US$3257) in Rwanda. Conclusion: We found important differences in unit costs along the HTC and PMTCT service cascades within and between countries suggesting that more efficient delivery of these services is possible. PMID:27753679

  20. Prediction of mass transfer coefficient in rotating bed contactor (Higee) using artificial neural network

    NASA Astrophysics Data System (ADS)

    Saha, Dipendu

    2009-02-01

    The feasibility of drastically reducing the contactor size in mass transfer processes utilizing centrifugal field has generated a lot of interest in rotating packed bed (Higee). Various investigators have proposed correlations to predict mass transfer coefficients in Higee, but, none of the correlations was more than 20-30% accurate. In this work, artificial neural network (ANN) is employed for predicting mass transfer coefficient data. Results show that ANN provides better estimation of mass transfer coefficient with accuracy 5-15%.

  1. Genetic polymorphisms within exon 3 of heat shock protein 90AA1 gene and its association with heat tolerance traits in Sahiwal cows

    PubMed Central

    Kumar, Rakesh; Gupta, I. D.; Verma, Archana; Verma, Nishant; Vineeth, M. R.

    2015-01-01

    Aim: The present study was undertaken to identify novel single nucleotide polymorphism (SNP) in Exon 3 of HSP90AA1 gene and to analyze their association with respiration rate (RR) and rectal temperature (RT) in Sahiwal cows. Materials and Methods: The present study was carried out in Sahiwal cows (n=100) with the objectives to identify novel SNP in exon 3 of HSP90AA1 gene and to explore the association with heat tolerance traits. CLUSTAL-W multiple sequence analysis was used to identify novel SNPs in exon 3 of HSP90AA1 gene in Sahiwal cows. Gene and genotype frequencies of different genotypes were estimated by standard procedure POPGENE version 1.32 (University of Alberta, Canada). The significant effect of SNP variants on physiological parameters, e.g. RR and RT were analyzed using the General Linear model procedure of SAS Version 9.2. Results: The polymerase chain reaction product with the amplicon size of 450 bp was successfully amplified, covering exon 3 region of HSP90AA1 gene in Sahiwal cows. On the basis of comparative sequence analysis of Sahiwal samples (n=100), transitional mutations were detected at locus A1209G as compared to Bos taurus (NCBI GenBank AC_000178.1). After chromatogram analysis, three genotypes AA, AG, and GG with respective frequencies of 0.23, 0.50, and 0.27 ascertained. RR and RT were recorded once during probable extreme hours in winter, spring, and summer seasons. It was revealed that significant difference (p<0.01) among genetic variants of HSP90AA1 gene with heat tolerance trait was found in Sahiwal cattle. The homozygotic animals with AA genotype had lower heat tolerance coefficient (HTC) (1.78±0.04a), as compared to both AG and GG genotypes (1.85±0.03b and 1.91±0.02c), respectively. The gene and genotype frequencies for the locus A1209G were ascertained. Conclusions: Novel SNP was found at the A1209G position showed all possible three genotypes (homozygous and heterozygous). Temperature humidity index has a highly significant association with RR, RT, and HTC in all the seasons. Perusal of results across different seasons showed the significant (p<0.01) difference in RR, RT, and HTC among winter, spring, and summer seasons. Genetic association with heat tolerance traits reveals their importance as a potential genetic marker for heat tolerance traits in Sahiwal cows. PMID:27047179

  2. Speciation evolution of zinc and copper during pyrolysis and hydrothermal carbonization treatments of sewage sludges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Rixiang; Zhang, Bei; Saad, Emily M.

    Thermal and hydrothermal treatments are promising techniques for sewage sludge management that can potentially facilitate safe waste disposal, energy recovery, and nutrient recovery/recycling. Content and speciation of heavy metals in the treatment products affect the potential environmental risks upon sludge disposal and/or application of the treatment products. Therefore, it is important to study the speciation transformation of heavy metals and the effects of treatment conditions. By combining synchrotron X-ray spectroscopy/microscopy analysis and sequential chemical extraction, this study systematically characterized the speciation of Zn and Cu in municipal sewage sludges and their chars derived from pyrolysis (a representative thermal treatment technique)more » and hydrothermal carbonization (HTC; a representative hydrothermal treatment technique). Spectroscopy analysis revealed enhanced sulfidation of Zn and Cu by anaerobic digestion and HTC treatments, as compared to desulfidation by pyrolysis. Overall, changes in the chemical speciation and matrix properties led to reduced mobility of Zn and Cu in the treatment products. These results provide insights into the reaction mechanisms during pyrolysis and HTC treatments of sludges and can help evaluate the environmental/health risks associated with the metals in the treatment products.« less

  3. An Effect of Dexamethasone on Adenosine 3′,5′ -Monophosphate Content and Adenosine 3′,5′ -Monophosphate Phosphodiesterase Activity of Cultured Hepatoma Cells

    PubMed Central

    Manganiello, Vincent; Vaughan, Martha

    1972-01-01

    The effect of dexamethasone on adenosine 3′,5′-monophosphate (cAMP) phosphodiesterase activity in cultured HTC hepatoma cells was investigated. Homogenates of these cells contain phosphodiesterase activity with two apparent Michaelis constants for cAMP (2-5 μm and 50 μm). At all substrate concentrations tested, phosphodiesterase activity was decreased 25-40% in cells incubated for 36 hr or more with 1 μm dexamethasone. Acid phosphatase activity in the same cells was not decreased. α-Methyl testosterone, 1 μm, was without effect on phosphodiesterase activity. Incubation for 10 min with epinephrine plus theophylline increased the cAMP content of the HTC cells 3- to 6-fold. In cells incubated for 72 hr with dexamethasone, the basal concentration of cAMP was slightly increased and the increment produced by epinephrine plus theophylline was markedly increased. We believe that in many cells the so-called permissive effects of steroid hormones on cAMP mediated processes may be due to an effect of these hormones on cAMP phosphodiesterase activity similar to that observed in HTC cells incubated with dexamethasone. PMID:4341439

  4. Cost and quality of life analysis of HIV self-testing and facility-based HIV testing and counselling in Blantyre, Malawi.

    PubMed

    Maheswaran, Hendramoorthy; Petrou, Stavros; MacPherson, Peter; Choko, Augustine T; Kumwenda, Felistas; Lalloo, David G; Clarke, Aileen; Corbett, Elizabeth L

    2016-02-19

    HIV self-testing (HIVST) has been found to be highly effective, but no cost analysis has been undertaken to guide the design of affordable and scalable implementation strategies. Consecutive HIV self-testers and facility-based testers were recruited from participants in a community cluster-randomised trial ( ISRCTN02004005 ) investigating the impact of offering HIVST in addition to facility-based HIV testing and counselling (HTC). Primary costing studies were undertaken of the HIVST service and of health facilities providing HTC to the trial population. Costs were adjusted to 2014 US$ and INT$. Recruited participants were asked about direct non-medical and indirect costs associated with accessing either modality of HIV testing, and additionally their health-related quality of life was measured using the EuroQol EQ-5D. A total of 1,241 participants underwent either HIVST (n = 775) or facility-based HTC (n = 446). The mean societal cost per participant tested through HIVST (US$9.23; 95 % CI: US$9.14-US$9.32) was lower than through facility-based HTC (US$11.84; 95 % CI: US$10.81-12.86). Although the mean health provider cost per participant tested through HIVST (US$8.78) was comparable to facility-based HTC (range: US$7.53-US$10.57), the associated mean direct non-medical and indirect cost was lower (US$2.93; 95 % CI: US$1.90-US$3.96). The mean health provider cost per HIV positive participant identified through HIVST was higher (US$97.50) than for health facilities (range: US$25.18-US$76.14), as was the mean cost per HIV positive individual assessed for anti-retroviral treatment (ART) eligibility and the mean cost per HIV positive individual initiated onto ART. In comparison to the facility-testing group, the adjusted mean EQ-5D utility score was 0.046 (95 % CI: 0.022-0.070) higher in the HIVST group. HIVST reduces the economic burden on clients, but is a costlier strategy for the health provider aiming to identify HIV positive individuals for treatment. The provider cost of HIVST could be substantially lower under less restrictive distribution models, or if costs of oral fluid HIV test kits become comparable to finger-prick kits used in health facilities.

  5. Investigation of two-phase heat transfer coefficients of argon-freon cryogenic mixed refrigerants

    NASA Astrophysics Data System (ADS)

    Baek, Seungwhan; Lee, Cheonkyu; Jeong, Sangkwon

    2014-11-01

    Mixed refrigerant Joule Thomson refrigerators are widely used in various kinds of cryogenic systems these days. Although heat transfer coefficient estimation for a multi-phase and multi-component fluid in the cryogenic temperature range is necessarily required in the heat exchanger design of mixed refrigerant Joule Thomson refrigerators, it has been rarely discussed so far. In this paper, condensation and evaporation heat transfer coefficients of argon-freon mixed refrigerant are measured in a microchannel heat exchanger. A Printed Circuit Heat Exchanger (PCHE) with 340 μm hydraulic diameter has been developed as a compact microchannel heat exchanger and utilized in the experiment. Several two-phase heat transfer coefficient correlations are examined to discuss the experimental measurement results. The result of this paper shows that cryogenic two-phase mixed refrigerant heat transfer coefficients can be estimated by conventional two-phase heat transfer coefficient correlations.

  6. An experimental approach to determine the heat transfer coefficient in directional solidification furnaces

    NASA Technical Reports Server (NTRS)

    Banan, Mohsen; Gray, Ross T.; Wilcox, William R.

    1992-01-01

    The heat transfer coefficient between a molten charge and its surroundings in a Bridgman furnace was experimentally determined using in-situ temperature measurement. The ampoule containing an isothermal melt was suddenly moved from a higher temperature zone to a lower temperature zone. The temperature-time history was used in a lumped-capacity cooling model to evaluate the heat transfer coefficient between the charge and the furnace. The experimentally determined heat transfer coefficient was of the same order of magnitude as the theoretical value estimated by standard heat transfer calculations.

  7. Evaluation of generalized heat-transfer coefficients in pilot AFBC units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grewal, N.S.

    Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.

  8. Evaluation of generalized heat transfer coefficients in pilot AFBC units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grewal, N.S.

    Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.

  9. What happens with the nitrogen in sewage sludge once this material is pyrolyzed?

    NASA Astrophysics Data System (ADS)

    Paneque, Marina; María De la Rosa, José; Kern, Jürgen; Knicker, Heike

    2017-04-01

    The transformation of sewage sludge (SS) into char by pyrolysis achieves sludge hygienization, a necessary step prior to a possible application on agricultural soils. Former studies indicated that during this process part of the organic nitrogen (No) of this material is incorporated into the aromatic network of the charred product and forms the so called black N (BN). De la Rosa and Knicker (2011) showed further that at least some of the BN is bioavailable. However, neither the pathways of BN formation nor its chemical structure is well understood. Therefore, we studied the production of inorganic N (Ni) and the forms of No after subjecting two types of SS to hydrothermal carbonization (HTC) and dry pyrolysis (Dry-Py). The samples were collected at two different stages of the wastewater treatment (hereafter A_SS and T_SS) at the Experimental Wastewater Treatment plant CENTA, located in Carrion de los Céspedes (Southern Spain). Four chars were produced by HTC at 200°C and 260°C, and with residence times of 30 min and 3 hours. Dry pyrolysis char was obtained after heating at 600°C for 1 hour. The organic N forms were revealed by solid-state 15N nuclear magnetic resonance (NMR) spectroscopy. All pyrolysis conditions resulted in a decrease of the amount of total N (Nt). Whereas HTC preserved between 83-59% of original N, only 2% were recovered in the char after Dry-Py. With respect to Ni, the amounts of ammonium and nitrite increased between 2 and 4 times compared to the non-treated SS after HTC. After Dry-Py no Ni was detected in the solid residue. The solid-state 15N NMR spectra of the non-treated SS are dominated by the signals assignable to amide-N. With increasing temperature and residence time applied during HTC, a shift of the signal intensity toward the region of pyrrole-N was evidenced. The largest contribution of pyrrole-N was identified in the sample obtained after heating at 260°C for 3h although the 15N-intensity in the chemical shift region of amide/carbazole N dominated the spectrum. In contrast, Dry-Py resulted in a dominance of pyrrole-N. In conclusion, our study demonstrated the impact of the pyrolysis conditions on the quantity and quality of N-forms in chars of SS. Considering the N fertilization potential, HTC chars may be more suitable than chars produced by Dry-Py if fast fertilization is needed due to the presence of Ni. On the other hand, the binding of N in heterocyclic structures retards its bioavailability. Thus Dry-Py chars will be a better choise, if slow N-release is wanted. However, deeper and specific researchers are necessary to confirm this hypothesis. De la Rosa JM, Knicker H (2011) Bioavailability of N released from N-rich pyrogenic organic matter: An incubation study. Soil Biology and Biogeochemistry 43: 2368-2373

  10. Experimental investigation of forced convective heat transfer performance in nanofluids of Al2O3/water and CuO/water in a serpentine shaped micro channel heat sink

    NASA Astrophysics Data System (ADS)

    Sivakumar, A.; Alagumurthi, N.; Senthilvelan, T.

    2016-07-01

    The microchannels are device used to remove high heat fluxes from smaller area. In this experimental research work the heat transfer performance of nanofluids of Al2O3/water and CuO/water were compared. The important character of such fluids is the enhanced thermal conductivity, in comparison with base fluid without considerable alteration in physical and chemical properties. The effect of forced convective heat transfer coefficient was calculated using serpentine shaped microchannel heat exchanger. Furthermore we calculated the forced convective heat transfer coefficient of the nanofluids using theoretical correlations in order to compare the results with the experimental data. The heat transfer coefficient for different particle concentration and temperature were analysed using forced convection heat transfer using nanofluids. The findings indicate considerable enhancement in convective heat transfer coefficient of the nanofluids as compared to the basefluid. The results also shows that CuO/water nanofluid has increased heat transfer coefficient compared with Al2O3/water and base fluids. Moreover the experimental results indicate there is increased forced convective heat transfer coefficient with the increase in nano particle concentration.

  11. Improvements of high-throughput culturing yielded novel SAR11 strains and other abundant marine bacteria from the Oregon coast and the Bermuda Atlantic Time Series study site.

    PubMed

    Stingl, Ulrich; Tripp, Harry James; Giovannoni, Stephen J

    2007-08-01

    The introduction of high-throughput dilution-to-extinction culturing (HTC) of marine bacterioplankton using sterilized natural sea water as media yielded isolates of many abundant but previously uncultured marine bacterial clades. In early experiments, bacteria from the SAR11 cluster (class Alphaproteobacteria), which are presumed to be the most abundant prokaryotes on earth, were cultured. Although many additional attempts were made, no further strains of the SAR11 clade were obtained. Here, we describe improvements to the HTC technique, which led to the isolation of 17 new SAR11 strains from the Oregon coast and the Sargasso Sea, accounting for 28% and 31% of all isolates in these experiments. Phylogenetic analysis of the internal transcribed spacer (ITS) region showed that the isolates from the Oregon coast represent three different subclusters of SAR11, while isolates from the Sargasso Sea were more uniform and represented a single ITS cluster. A PCR assay proved the presence of proteorhodopsin (PR) in nearly all SAR11 isolates. Analysis of PR amino-acid sequences indicated that isolates from the Oregon coast were tuned to either green or blue light, while PRs from strains obtained from the Sargasso Sea were exclusively tuned to maximum absorbance in the blue. Interestingly, phylogenies based on PR and ITS did not correlate, suggesting lateral gene transfer. In addition to the new SAR11 strains, many novel strains belonging to clusters of previously uncultured or undescribed species of different bacterial phyla, including the first strain of the highly abundant alphaproteobacterial SAR116 clade, were isolated using the modified methods.

  12. Towards Defining the Ecological Niches of Novel Coastal Gulf of Mexico Bacterial Isolates

    NASA Astrophysics Data System (ADS)

    Henson, M. W.; Thrash, C.; Nall, E.

    2016-02-01

    The study of microbial contributions to biogeochemistry is critical to understanding the cycles of fundamental compounds and gain predictive capabilities in a changing environment. Such study requires observation of microbial communities and genetics in nature, coupled with experimental testing of hypotheses both in situ and in laboratory settings. This study combines dilution-to-extinction based high-throughput culturing (HTC) with cultivation-independent and geochemical measurements to define potential ecological niches of novel bacterial isolates from the coastal northern Gulf of Mexico (cnGOM). Here we report findings from the first of a three-year project. In total, 43 cultures from seven HTC experiments were capable of being repeatedly transferred. Sanger sequencing of the 16S rRNA gene identified these isolates as belonging to the phyla Gammaproteobacteria, Alphaproteobacteria, Actinobacteria, and Betaproteobacteria. Eight are being genome sequenced, with two selected for further physiological characterization due to their phylogenic novelty and potential ecological significance. Strain LSUCC101 likely represents a novel family of Gammaproteobacteria (best blast hit to a cultured representative showed 91% sequence identity) and strain LSUCC96 belongs to the OM252 clade, with the Hawaiian isolate HIMB30 as its closest relative. Both are small (0.3-0.5 µm) cocci. The environmental importance of both LSUCC101 and LSUCC96 was illustrated by their presence within the top 30 OTU0.03 of cnGOM 16S rRNA gene datasets as well as within clone libraries from coastal regions around the world. Ongoing work is determining growth efficiencies, substrate utilization profiles, and metabolic potential to elucidate the roles of these organisms in the cnGOM. Comparative genomics will examine the evolutionary divergence of these organisms from their closest neighbors, and metagenomic recruitment to genomes will help identify strain-based variation from different coastal regions.

  13. Preoperative prognostic value of dynamic contrast-enhanced MRI-derived contrast transfer coefficient and plasma volume in patients with cerebral gliomas.

    PubMed

    Nguyen, T B; Cron, G O; Mercier, J F; Foottit, C; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Caudrelier, J M; Sinclair, J; Hogan, M J; Thornhill, R E; Cameron, I G

    2015-01-01

    The prognostic value of dynamic contrast-enhanced MR imaging-derived plasma volume obtained in tumor and the contrast transfer coefficient has not been well-established in patients with gliomas. We determined whether plasma volume and contrast transfer coefficient in tumor correlated with survival in patients with gliomas in addition to other factors such as age, type of surgery, preoperative Karnofsky score, contrast enhancement, and histopathologic grade. This prospective study included 46 patients with a new pathologically confirmed diagnosis of glioma. The contrast transfer coefficient and plasma volume obtained in tumor maps were calculated directly from the signal-intensity curve without T1 measurements, and values were obtained from multiple small ROIs placed within tumors. Survival curve analysis was performed by dichotomizing patients into groups of high and low contrast transfer coefficient and plasma volume. Univariate analysis was performed by using dynamic contrast-enhanced parameters and clinical factors. Factors that were significant on univariate analysis were entered into multivariate analysis. For all patients with gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). In subgroups of high- and low-grade gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). Univariate analysis showed that factors associated with lower survival were age older than 50 years, low Karnofsky score, biopsy-only versus resection, marked contrast enhancement versus no/mild enhancement, high contrast transfer coefficient, and high plasma volume obtained in tumor (P < .05). In multivariate analysis, a low Karnofsky score, biopsy versus resection in combination with marked contrast enhancement, and a high contrast transfer coefficient were associated with lower survival rates (P < .05). In patients with glioma, those with a high contrast transfer coefficient have lower survival than those with low parameters. © 2015 by American Journal of Neuroradiology.

  14. External Heat Transfer Coefficient Measurements on a Surrogate Indirect Inertial Confinement Fusion Target

    DOE PAGES

    Miles, Robin; Havstad, Mark; LeBlanc, Mary; ...

    2015-09-15

    External heat transfer coefficients were measured around a surrogate Indirect inertial confinement fusion (ICF) based on the Laser Inertial Fusion Energy (LIFE) design target to validate thermal models of the LIFE target during flight through a fusion chamber. Results indicate that heat transfer coefficients for this target 25-50 W/m 2∙K are consistent with theoretically derived heat transfer coefficients and valid for use in calculation of target heating during flight through a fusion chamber.

  15. Measurements of Heat-Transfer and Friction Coefficients for Helium Flowing in a Tube at Surface Temperatures up to 5900 Deg R

    NASA Technical Reports Server (NTRS)

    Taylor, Maynard F.; Kirchgessner, Thomas A.

    1959-01-01

    Measurements of average heat transfer and friction coefficients and local heat transfer coefficients were made with helium flowing through electrically heated smooth tubes with length-diameter ratios of 60 and 92 for the following range of conditions: Average surface temperature from 1457 to 4533 R, Reynolds numbe r from 3230 to 60,000, heat flux up to 583,200 Btu per hr per ft2 of heat transfer area, and exit Mach numbe r up to 1.0. The results indicate that, in the turbulent range of Reynolds number, good correlation of the local heat transfer coefficients is obtained when the physical properties and density of helium are evaluated at the surface temperature. The average heat transfer coefficients are best correlated on the basis that the coefficient varies with [1 + (L/D))(sup -0,7)] and that the physical properties and density are evaluated at the surface temperature. The average friction coefficients for the tests with no heat addition are in complete agreement with the Karman-Nikuradse line. The average friction coefficients for heat addition are in poor agreement with the accepted line.

  16. [Correlation of molecular weight and nanofiltration mass transfer coefficient of phenolic acid composition from Salvia miltiorrhiza].

    PubMed

    Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping

    2018-04-01

    Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.

  17. Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

    PubMed

    Fukuda, Makoto; Yoshimura, Kengo; Namekawa, Koki; Sakai, Kiyotaka

    2017-06-01

    The objective of the present study is to evaluate the effect of filtration coefficient and internal filtration on dialysis fluid flow and mass transfer coefficient in dialyzers using dimensionless mass transfer correlation equations. Aqueous solution of vitamin B 12 clearances were obtained for REXEED-15L as a low flux dialyzer, and APS-15EA and APS-15UA as high flux dialyzers. All the other design specifications were identical for these dialyzers except for filtration coefficient. The overall mass transfer coefficient was calculated, moreover, the exponents of Reynolds number (Re) and film mass transfer coefficient of the dialysis-side fluid (k D ) for each flow rate were derived from the Wilson plot and dimensionless correlation equation. The exponents of Re were 0.4 for the low flux dialyzer whereas 0.5 for the high flux dialyzers. Dialysis fluid of the low flux dialyzer was close to laminar flow because of its low filtration coefficient. On the other hand, dialysis fluid of the high flux dialyzers was assumed to be orthogonal flow. Higher filtration coefficient was associated with higher k D influenced by mass transfer rate through diffusion and internal filtration. Higher filtration coefficient of dialyzers and internal filtration affect orthogonal flow of dialysis fluid.

  18. Heat transfer coefficient of cryotop during freezing.

    PubMed

    Li, W J; Zhou, X L; Wang, H S; Liu, B L; Dai, J J

    2013-01-01

    Cryotop is an efficient vitrification method for cryopreservation of oocytes. It has been widely used owing to its simple operation and high freezing rate. Recently, the heat transfer performance of cryotop was studied by numerical simulation in several studies. However, the range of heat transfer coefficient in the simulation is uncertain. In this study, the heat transfer coefficient for cryotop during freezing process was analyzed. The cooling rates of 40 percent ethylene glycol (EG) droplet in cryotop during freezing were measured by ultra-fast measurement system and calculated by numerical simulation at different value of heat transfer coefficient. Compared with the results obtained by two methods, the range of the heat transfer coefficient necessary for the numerical simulation of cryotop was determined, which is between 9000 W/(m(2)·K) and 10000 W/(m (2)·K).

  19. [The balance of harmful trace contaminants between the air humidity condensate and air in a simulator of the Mir orbit station moisture condensation unit].

    PubMed

    Zlotopol'skiĭ, V M; Smolenskaia, T S

    2000-01-01

    Subject of the investigation was the balance of harmful trace contaminants (HTC) between the air moisture condensate and air in a simulator of the MIR moisture condensation unit. Experiments involved various classes of water-solvent compounds including alcohols (C1-C4), ketons (C1-C2), aldehydes (C1-C2), fatty acids (C2-C4), esters (acetates C4-C6), and ammonium. For most of the compounds, removal efficiency correlates with air humidity and virtually does not depend on the HTC concentration within the range of 0.25 to 59.1 mg/m3.

  20. Numerical Calculation of the Peaking Factor of a Water-Cooled W/Cu Monoblock for a Divertor

    NASA Astrophysics Data System (ADS)

    Han, Le; Chang, Haiping; Zhang, Jingyang; Xu, Tiejun

    2015-09-01

    In order to accurately predict the incident critical heat flux (ICHF, the heat flux at the heated surface when CHF occurs) of a water-cooled W/Cu monoblock for a divertor, the exact knowledge of its peaking factors (fp) under one-sided heating conditions with different design parameters is a key issue. In this paper, the heat conduction in the solid domain of a water-cooled W/Cu monoblock is calculated numerically by assuming the local heat transfer coefficients (HTC) of the cooling wall to be functions of the local wall temperature, so as to obtain fp. The reliability of the calculation method is validated by an experimental example result, with the maximum error of 2.1% only. The effects of geometric and flow parameters on the fp of a water-cooled W/Cu monoblock are investigated. Within the scope of this study, it is shown that the fp increases with increasing dimensionless W/Cu monoblock width and armour thickness (the shortest distance between the heated surface and Cu layer), and the maximum increases are 43.8% and 22.4% respectively. The dimensionless W/Cu monoblock height and Cu thickness have little effect on fp. The increase of Reynolds number and Jakob number causes the increase of fp, and the maximum increases are 6.8% and 9.6% respectively. Based on the calculated results, an empirical correlation on peaking factor is obtained via regression. These results provide a valuable reference for the thermal-hydraulic design of water-cooled divertors. supported by National Magnetic Confinement Fusion Science Program of China (No. 2010GB104005) and Funding of Jiangsu Innovation Program for Graduate Education, China (CXLX12_0170), the Fundamental Research Funds for the Central Universities of China

  1. Natural circulation in a liquid metal one-dimensional loop

    NASA Astrophysics Data System (ADS)

    Tarantino, M.; De Grandis, S.; Benamati, G.; Oriolo, F.

    2008-06-01

    A wide use of pure lead, as well as its alloys (such as lead-bismuth, lead-lithium), is foreseen in several nuclear-related fields: it is studied as coolant in critical and sub-critical nuclear reactors, as spallation target for neutron generation in several applications and for tritium generation in fusion systems. In this framework, a new facility named NAtural CIrculation Experiment (NACIE), has been designed at ENEA-Brasimone Research Centre. NACIE is a rectangular loop, made by stainless steel pipes. It consists mainly of a cold and hot leg and an expansion tank installed on the top of the loop. A fuel bundle simulator, made by three electrical heaters placed in a triangular lattice, is located in the lower part of the cold leg, while a tube in tube heat exchanger is installed in the upper part of the hot leg. The adopted secondary fluid is THT oil, while the foreseen primary fluid for the tests is lead-bismuth in eutectic composition (LBE). The aim of the facility is to carry out experimental tests of natural circulation and collect data on the heat transfer coefficient (HTC) for heavy liquid metal flowing through rod bundles. The paper is focused on the preliminary estimation of the LBE flow rate along the loop. An analytical methodology has been applied, solving the continuity, momentum and energy transport equations under appropriate hypothesis. Moreover numerical simulations have been performed. The FLUENT 6.2 CFD code has been utilized for the numerical simulations. The main results carried out from the pre-tests simulations are illustrated in the paper, and a comparison with the theoretical estimations is done.

  2. The role of intra-NAPL diffusion on mass transfer from MGP residuals

    NASA Astrophysics Data System (ADS)

    Shafieiyoun, Saeid; Thomson, Neil R.

    2018-06-01

    An experimental and computational study was performed to investigate the role of multi-component intra-NAPL diffusion on NAPL-water mass transfer. Molecular weight and the NAPL component concentrations were determined to be the most important parameters affecting intra-NAPL diffusion coefficients. Four NAPLs with different viscosities but the same quantified mass were simulated. For a spherical NAPL body, a combination of NAPL properties and interphase mass transfer rate can result in internal diffusion limitations. When the main intra-NAPL diffusion coefficients are in the range of self-diffusion coefficients (10-5 to 10-6 cm2/s), dissolution is not limited by internal diffusion except for high mass transfer rate coefficients (>180 cm/day). For a complex and relatively high viscous NAPL (>50 g/(cm s)), smaller intra-NAPL diffusion coefficients (<10-8) are expected and even low mass transfer rate coefficients ( 6 cm/day) can result in diffusion-limited dissolution.

  3. The measurement of the heat-transfer coefficient between high-temperature liquids and solid surfaces

    NASA Astrophysics Data System (ADS)

    Utigard, T. A.; Warczok, A.; Desclaux, P.

    1994-01-01

    Two experimental techniques were developed for the purpose of measuring the heat-transfer coefficient between liquid slags/salts and solid surfaces. This was carried out because the heat-transfer coefficient is important for the design and operation of metallurgical reactors. A “cold-finger” technique was developed for the purpose of carrying out heat-transfer measurements during steady-state conditions simulating heat fluxes through furnace sidewalls. A lump capacitance method was developed and tested for the purpose of simulating transient conditions. To determine the effect of fluid flow on the heat-transfer coefficient, nitrogen gas stirring was used. The two techniques were tested in molten (1) and NaNO3, (2) NaCl, (3) Na3AlF6, and (4) 2FeO·SiO2, giving consistent results. It was found that the heat-transfer coefficient increases with increasing bath superheat and stirring.

  4. Influence of Oil on Refrigerant Evaporator Performance

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Soo; Nagata, Karsuya; Katsuta, Masafumi; Tomosugi, Hiroyuki; Kikuchi, Kouichiro; Horichi, Toshiaki

    In vapor compression refrigeration system using oil-lubricated compressors, some amount of oil is always circulated through the system. Oil circulation can have a significant influence on the evaporator performance of automotive air conditioner which is especially required to cool quickly the car interior after a period standing in the sun. An experimental investigation was carried out an electrically heated horizontal tube to measure local heat transfer coefficients for various flow rates and heat fluxes during forced convection boiling of pure refrigerant R12 and refrigerant-oil mixtures (0-11% oil concentration by weight) and the results were compared with oil free performance. Local heat transfer coefficients increased at the region of low vapor quality by the addition of oil. On the other hand, because the oil-rich liquid film was formed on the heat transfer surface, heat transfer coefficients gradually decreased as the vapor quality became higher. Average heat transfer coefficient reached a maximum at about 4% oil concentration and this trend agreed well with the results of Green and Furse. Previous correlations, using the properties of the refrigerant-oil mixture, could not predict satisfactorily the local heat transfer coefficients data. New correlation modified by oil concentration factor was developed for predicting the corresponding heat transfer coefficient for refrigerant-oil mixture convection boiling. The maximum percent deviation between predicted and measured heat transfer coefficient was within ±30%.

  5. Integration of the HTC Vive into the medical platform MeVisLab

    NASA Astrophysics Data System (ADS)

    Egger, Jan; Gall, Markus; Wallner, Jürgen; de Almeida Germano Boechat, Pedro; Hann, Alexander; Li, Xing; Chen, Xiaojun; Schmalstieg, Dieter

    2017-03-01

    Virtual Reality (VR) is an immersive technology that replicates an environment via computer-simulated reality. VR gets a lot of attention in computer games but has also great potential in other areas, like the medical domain. Examples are planning, simulations and training of medical interventions, like for facial surgeries where an aesthetic outcome is important. However, importing medical data into VR devices is not trivial, especially when a direct connection and visualization from your own application is needed. Furthermore, most researcher don't build their medical applications from scratch, rather they use platforms, like MeVisLab, Slicer or MITK. The platforms have in common that they integrate and build upon on libraries like ITK and VTK, further providing a more convenient graphical interface to them for the user. In this contribution, we demonstrate the usage of a VR device for medical data under MeVisLab. Therefore, we integrated the OpenVR library into MeVisLab as an own module. This enables the direct and uncomplicated usage of head mounted displays, like the HTC Vive under MeVisLab. Summarized, medical data from other MeVisLab modules can directly be connected per drag-and-drop to our VR module and will be rendered inside the HTC Vive for an immersive inspection.

  6. Comparison Of Eigenvector-Based Statistical Pattern Recognition Algorithms For Hybrid Processing

    NASA Astrophysics Data System (ADS)

    Tian, Q.; Fainman, Y.; Lee, Sing H.

    1989-02-01

    The pattern recognition algorithms based on eigenvector analysis (group 2) are theoretically and experimentally compared in this part of the paper. Group 2 consists of Foley-Sammon (F-S) transform, Hotelling trace criterion (HTC), Fukunaga-Koontz (F-K) transform, linear discriminant function (LDF) and generalized matched filter (GMF). It is shown that all eigenvector-based algorithms can be represented in a generalized eigenvector form. However, the calculations of the discriminant vectors are different for different algorithms. Summaries on how to calculate the discriminant functions for the F-S, HTC and F-K transforms are provided. Especially for the more practical, underdetermined case, where the number of training images is less than the number of pixels in each image, the calculations usually require the inversion of a large, singular, pixel correlation (or covariance) matrix. We suggest solving this problem by finding its pseudo-inverse, which requires inverting only the smaller, non-singular image correlation (or covariance) matrix plus multiplying several non-singular matrices. We also compare theoretically the effectiveness for classification with the discriminant functions from F-S, HTC and F-K with LDF and GMF, and between the linear-mapping-based algorithms and the eigenvector-based algorithms. Experimentally, we compare the eigenvector-based algorithms using a set of image data bases each image consisting of 64 x 64 pixels.

  7. Comparative Study of the Structure of Hydroproducts Derived from Loblolly Pine and Straw Grass

    DOE PAGES

    Wu, Qiong; Huang, Lang; Yu, Shitao; ...

    2017-05-26

    We investigated the structural characteristics of products derived from the hydrothermal carbonization (HTC) of loblolly pine (LP) and straw grass (SG) via solid-state cross-polarization/magic angle spinning nuclear magnetic resonance (CP/MAS 13C NMR), heteronuclear single-quantum correlation nuclear magnetic resonance (HSQC-NMR), and solution 13C NMR and 31P NMR techniques. Our results revealed that after HTC, hydrochars from both LP and SG mainly consisted of a combination of lignin, furfural, and condensed polyaromatic structures with a high level of fixed carbon content and higher heating value (HHV). Hydrochar from LP exhibited a higher aryl to furan ratio, and those from SG contained moremore » aliphatic functional groups. Solution 13C NMR and HSQC revealed that both liquid chemicals were condensed polyphenolic structures with aliphatic groups that exist mainly in the form of side chains. Although the LP products exhibited a higher proportion of aromatic structures, the types of polyphenol and aliphatic C–H were more diverse in the SG products. Results also indicated that reactions such as chain scission and condensation occurred during hydrothermal carbonization processes. Overall, HTC was found to be an effective refinery treatment for converting different waste biomass into valuable energy materials and chemicals.« less

  8. Comparative Study of the Structure of Hydroproducts Derived from Loblolly Pine and Straw Grass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Qiong; Huang, Lang; Yu, Shitao

    We investigated the structural characteristics of products derived from the hydrothermal carbonization (HTC) of loblolly pine (LP) and straw grass (SG) via solid-state cross-polarization/magic angle spinning nuclear magnetic resonance (CP/MAS 13C NMR), heteronuclear single-quantum correlation nuclear magnetic resonance (HSQC-NMR), and solution 13C NMR and 31P NMR techniques. Our results revealed that after HTC, hydrochars from both LP and SG mainly consisted of a combination of lignin, furfural, and condensed polyaromatic structures with a high level of fixed carbon content and higher heating value (HHV). Hydrochar from LP exhibited a higher aryl to furan ratio, and those from SG contained moremore » aliphatic functional groups. Solution 13C NMR and HSQC revealed that both liquid chemicals were condensed polyphenolic structures with aliphatic groups that exist mainly in the form of side chains. Although the LP products exhibited a higher proportion of aromatic structures, the types of polyphenol and aliphatic C–H were more diverse in the SG products. Results also indicated that reactions such as chain scission and condensation occurred during hydrothermal carbonization processes. Overall, HTC was found to be an effective refinery treatment for converting different waste biomass into valuable energy materials and chemicals.« less

  9. Local convective heat transfer coefficient and friction factor of CuO/water nanofluid in a microchannel heat sink

    NASA Astrophysics Data System (ADS)

    Chabi, A. R.; Zarrinabadi, S.; Peyghambarzadeh, S. M.; Hashemabadi, S. H.; Salimi, M.

    2017-02-01

    Forced convective heat transfer in a microchannel heat sink (MCHS) using CuO/water nanofluids with 0.1 and 0.2 vol% as coolant was investigated. The experiments were focused on the heat transfer enhancement in the channel entrance region at Re < 1800. Hydraulic performance of the MCHS was also estimated by measuring friction factor and pressure drop. Results showed that higher convective heat transfer coefficient was obtained at the microchannel entrance. Maximum enhancement of the average heat transfer coefficient compared with deionized water was about 40 % for 0.2 vol% nanofluid at Re = 1150. Enhancement of the convective heat transfer coefficient of nanofluid decreased with further increasing of Reynolds number.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Graczyk, D.G.

    The ACL activities covered IFR fuel reprocessing, corium-concrete interactions, environmental samples, wastes, WIPP support, Advanced Photon Source, H-Tc superconductors, EBWR vessel, soils, illegal drug detection, quality control, etc.

  11. Effects of an HIV peer prevention intervention on sexual and injecting risk behaviors among injecting drug users and their risk partners in Thai Nguyen, Vietnam: a randomized controlled trial.

    PubMed

    Go, Vivian F; Frangakis, Constantine; Le Minh, Nguyen; Latkin, Carl A; Ha, Tran Viet; Mo, Tran Thi; Sripaipan, Teerada; Davis, Wendy; Zelaya, Carla; Vu, Pham The; Chen, Yong; Celentano, David D; Quan, Vu Minh

    2013-11-01

    Globally, 30% of new HIV infections outside sub-Saharan Africa involve injecting drug users (IDU) and in many countries, including Vietnam, HIV epidemics are concentrated among IDU. We conducted a randomized controlled trial in Thai Nguyen, Vietnam, to evaluate whether a peer oriented behavioral intervention could reduce injecting and sexual HIV risk behaviors among IDU and their network members. 419 HIV-negative index IDU aged 18 years or older and 516 injecting and sexual network members were enrolled. Each index participant was randomly assigned to receive a series of six small group peer educator-training sessions and three booster sessions in addition to HIV testing and counseling (HTC) (intervention; n = 210) or HTC only (control; n = 209). Follow-up, including HTC, was conducted at 3, 6, 9 and 12 months post-intervention. The proportion of unprotected sex dropped significantly from 49% to 27% (SE (difference) = 3%, p < 0.01) between baseline and the 3-month visit among all index-network member pairs. However, at 12 months, post-intervention, intervention participants had a 14% greater decline in unprotected sex relative to control participants (Wald test = 10.8, df = 4, p = 0.03). This intervention effect is explained by trial participants assigned to the control arm who missed at least one standardized HTC session during follow-up and subsequently reported increased unprotected sex. The proportion of observed needle/syringe sharing dropped significantly between baseline and the 3-month visit (14% vs. 3%, SE (difference) = 2%, p < 0.01) and persisted until 12 months, but there was no difference across trial arms (Wald test = 3.74, df = 3, p = 0.44). Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Experimental estimation of convective heat transfer coefficient from pulsating semi-confined impingement air slot jet by using inverse method

    NASA Astrophysics Data System (ADS)

    Farahani, Somayeh Davoodabadi; Kowsary, Farshad

    2017-09-01

    An experimental study on pulsating impingement semi-confined slot jet has been performed. The effect of pulsations frequency was examined for various Reynolds numbers and Nozzle to plate distances. Convective heat transfer coefficient is estimated using the measured temperatures in the target plate and conjugate gradient method with adjoint equation. Heat transfer coefficient in Re < 3000 tended to increase with increasing frequency. The pulsations enhance mixing, which results in an enhancement of mean flow velocity. In case of turbulent jet (Re > 3000), heat transfer coefficient is affected by the pulsation from particular frequency. In this study, the threshold Strouhal number (St) is 0.11. No significant heat transfer enhancement was obtained for St < 0.11. The thermal resistance is smaller each time due to the newly forming thermal boundary layers. Heat transfer coefficient increases due to decrease thermal resistance. This study shows that maximum enhancement in heat transfer due to pulsations occurs in St = 0.169. Results show the configuration geometry has an important effect on the heat transfer performances in pulsed impinging jet. Heat transfer enhancement can be described to reflect flow by the confinement plate.

  13. Transfer coefficients in ultracold strongly coupled plasma

    NASA Astrophysics Data System (ADS)

    Bobrov, A. A.; Vorob'ev, V. S.; Zelener, B. V.

    2018-03-01

    We use both analytical and molecular dynamic methods for electron transfer coefficients in an ultracold plasma when its temperature is small and the coupling parameter characterizing the interaction of electrons and ions exceeds unity. For these conditions, we use the approach of nearest neighbor to determine the average electron (ion) diffusion coefficient and to calculate other electron transfer coefficients (viscosity and electrical and thermal conductivities). Molecular dynamics simulations produce electronic and ionic diffusion coefficients, confirming the reliability of these results. The results compare favorably with experimental and numerical data from earlier studies.

  14. Heat transfer in freeboard region of fluidized beds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biyikli, S.; Tuzla, K.; Chen, J.C.

    1983-10-01

    This research involved the study of heat transfer and fluid mechanic characteristics around a horizontal tube in the freeboard region of fluidized beds. Heat transfer coefficients were experimetnally measured for different bed temperatures, particle sizes, gas flow rates, and tube elevations in the freeboard region of air fluidized beds at atmospheric pressure. Local heat transfer coefficients were found to vary significantly with angular position around the tube. Average heat transfer coefficients were found to decrease with increasing freeboard tube elevation and approach the values for gas convection plus radiation for any given gas velocity. For a fixed tube elevation, heatmore » transfer coefficients generally increased with increasing gas velocity and with high particle entrainment they can approach the magnitudes found for immersed tubes. Heat transfer coefficients were also found to increase with increasing bed temperature. It was concluded that this increase is partly due to increase of radiative heat transfer and partly due to change of thermal properties of the fluidizing gas and particles. To investigate the fluid mechanic behavior of gas and particles around a freeboard tube, transient particle tube contacts were measured with a special capacitance probe in room temperature experiments. The results indicated that the tube surface experiences alternating dense and lean phase contacts. Quantitative information for local characteristics was obtained from the capacitance signals and used to develop a phenomenological model for prediction of the heat transfer coefficients around freeboard tubes. The packet renewal theory was modified to account for the dense phase heat transfer and a new model was suggested for the lean phase heat transfer. Finally, an empirical freeboard heat transfer correlation was developed from functional analysis of the freeboard heat transfer data using nondimensional groups representing gas velocity and tube elevation.« less

  15. Characteristics of heat exchange in the region of injection into a supersonic high-temperature flow

    NASA Technical Reports Server (NTRS)

    Bakirov, F. G.; Shaykhutdinov, Z. G.

    1985-01-01

    An experimental investigation of the local heat transfer coefficient distribution during gas injection into the supersonic-flow portion of a Laval nozzle is discussed. The controlling dimensionless parameters of the investigated process are presented in terms of a generalized relation for the maximum value of the heat transfer coefficient in the nozzle cross section behind the injection hole. Data on the heat transfer coefficient variation along the nozzle length as a function of gas injection rate are also presented, along with the heat transfer coefficient distribution over a cross section of the nozzle.

  16. Heat Transfer and Flow on the Squealer Tip of a Gas Turbine Blade

    NASA Technical Reports Server (NTRS)

    Azad, Gm S.; Han, Je-Chin; Boyle, Robert J.

    2000-01-01

    Experimental investigations are performed to measure the detailed heat transfer coefficient and static pressure distributions on the squealer tip of a gas turbine blade in a five-bladed stationary linear cascade. The blade is a 2-dimensional model of a modem first stage gas turbine rotor blade with a blade tip profile of a GE-E(sup 3) aircraft gas turbine engine rotor blade. A squealer (recessed) tip with a 3.77% recess is considered here. The data on the squealer tip are also compared with a flat tip case. All measurements are made at three different tip gap clearances of about 1%, 1.5%, and 2.5% of the blade span. Two different turbulence intensities of 6.1% and 9.7% at the cascade inlet are also considered for heat transfer measurements. Static pressure measurements are made in the mid-span and near-tip regions, as well as on the shroud surface opposite to the blade tip surface. The flow condition in the test cascade corresponds to an overall pressure ratio of 1.32 and an exit Reynolds number based on the axial chord of 1.1 x 10(exp 6). A transient liquid crystal technique is used to measure the heat transfer coefficients. Results show that the heat transfer coefficient on the cavity surface and rim increases with an increase in tip clearance. 'Me heat transfer coefficient on the rim is higher than the cavity surface. The cavity surface has a higher heat transfer coefficient near the leading edge region than the trailing edge region. The heat transfer coefficient on the pressure side rim and trailing edge region is higher at a higher turbulence intensity level of 9.7% over 6.1 % case. However, no significant difference in local heat transfer coefficient is observed inside the cavity and the suction side rim for the two turbulence intensities. The squealer tip blade provides a lower overall heat transfer coefficient when compared to the flat tip blade.

  17. A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

    NASA Technical Reports Server (NTRS)

    Porro, A. R.; Keith, T. G., Jr.; Hingst, W. R.

    1991-01-01

    A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high speed flow fields.

  18. A laser-induced heat flux technique for convective heat transfer measurements in high speed flows

    NASA Technical Reports Server (NTRS)

    Porro, A. R.; Keith, T. G., Jr.; Hingst, W. R.

    1991-01-01

    A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to the heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the local surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimentally determined convective heat transfer coefficients were generally higher than the theoretical predictions for flat plate laminar boundary layers. However, the results indicate that this nonintrusive optical measurement technique has the potential to measure surface convective heat transfer coefficients in high-speed flowfields.

  19. Modeling of the heat transfer performance of plate-type dispersion nuclear fuel elements

    NASA Astrophysics Data System (ADS)

    Ding, Shurong; Huo, Yongzhong; Yan, XiaoQing

    2009-08-01

    Considering the mutual actions between fuel particles and the metal matrix, the three-dimensional finite element models are developed to simulate the heat transfer behaviors of dispersion nuclear fuel plates. The research results indicate that the temperatures of the fuel plate might rise more distinctly with considering the particle swelling and the degraded surface heat transfer coefficients with increasing burnup; the local heating phenomenon within the particles appears when their thermal conductivities are too low. With rise of the surface heat transfer coefficients, the temperatures within the fuel plate decrease; the temperatures of the fuel plate are sensitive to the variations of the heat transfer coefficients whose values are lower, but their effects are weakened and slight when the heat transfer coefficients increase and reach a certain extent. Increasing the heat generation rate leads to elevating the internal temperatures. The temperatures and the maximum temperature differences within the plate increase along with the particle volume fractions. The surface thermal flux goes up along with particle volume fractions and heat generation rates, but the effects of surface heat transfer coefficients are not evident.

  20. Sphere Drag and Heat Transfer

    NASA Astrophysics Data System (ADS)

    Duan, Zhipeng; He, Boshu; Duan, Yuanyuan

    2015-07-01

    Modelling fluid flows past a body is a general problem in science and engineering. Historical sphere drag and heat transfer data are critically examined. The appropriate drag coefficient is proposed to replace the inertia type definition proposed by Newton. It is found that the appropriate drag coefficient is a desirable dimensionless parameter to describe fluid flow physical behavior so that fluid flow problems can be solved in the simple and intuitive manner. The appropriate drag coefficient is presented graphically, and appears more general and reasonable to reflect the fluid flow physical behavior than the traditional century old drag coefficient diagram. Here we present drag and heat transfer experimental results which indicate that there exists a relationship in nature between the sphere drag and heat transfer. The role played by the heat flux has similar nature as the drag. The appropriate drag coefficient can be related to the Nusselt number. This finding opens new possibilities in predicting heat transfer characteristics by drag data. As heat transfer for flow over a body is inherently complex, the proposed simple means may provide an insight into the mechanism of heat transfer for flow past a body.

  1. Sphere Drag and Heat Transfer.

    PubMed

    Duan, Zhipeng; He, Boshu; Duan, Yuanyuan

    2015-07-20

    Modelling fluid flows past a body is a general problem in science and engineering. Historical sphere drag and heat transfer data are critically examined. The appropriate drag coefficient is proposed to replace the inertia type definition proposed by Newton. It is found that the appropriate drag coefficient is a desirable dimensionless parameter to describe fluid flow physical behavior so that fluid flow problems can be solved in the simple and intuitive manner. The appropriate drag coefficient is presented graphically, and appears more general and reasonable to reflect the fluid flow physical behavior than the traditional century old drag coefficient diagram. Here we present drag and heat transfer experimental results which indicate that there exists a relationship in nature between the sphere drag and heat transfer. The role played by the heat flux has similar nature as the drag. The appropriate drag coefficient can be related to the Nusselt number. This finding opens new possibilities in predicting heat transfer characteristics by drag data. As heat transfer for flow over a body is inherently complex, the proposed simple means may provide an insight into the mechanism of heat transfer for flow past a body.

  2. Determination of blade-to-coolant heat-transfer coefficients on a forced-convection, water-cooled, single-stage turbine

    NASA Technical Reports Server (NTRS)

    Freche, John C; Schum, Eugene F

    1951-01-01

    Blade-to-coolant convective heat-transfer coefficients were obtained on a forced-convection water-cooled single-stage turbine over a large laminar flow range and over a portion of the transition range between laminar and turbulent flow. The convective coefficients were correlated by the general relation for forced-convection heat transfer with laminar flow. Natural-convection heat transfer was negligible for this turbine over the Grashof number range investigated. Comparison of turbine data with stationary tube data for the laminar flow of heated liquids showed good agreement. Calculated average midspan blade temperatures using theoretical gas-to-blade coefficients and blade-to-coolant coefficients from stationary-tube data resulted in close agreement with experimental data.

  3. Heat Transfer of Nanofluid in a Double Pipe Heat Exchanger.

    PubMed

    Aghayari, Reza; Maddah, Heydar; Zarei, Malihe; Dehghani, Mehdi; Kaskari Mahalle, Sahar Ghanbari

    2014-01-01

    This paper investigates the enhancement of heat transfer coefficient and Nusselt number of a nanofluid containing nanoparticles (γ-AL2O3) with a particle size of 20 nm and volume fraction of 0.1%-0.3% (V/V). Effects of temperature and concentration of nanoparticles on Nusselt number changes and heat transfer coefficient in a double pipe heat exchanger with counter turbulent flow are investigated. Comparison of experimental results with valid theoretical data based on semiempirical equations shows an acceptable agreement. Experimental results show a considerable increase in heat transfer coefficient and Nusselt number up to 19%-24%, respectively. Also, it has been observed that the heat transfer coefficient increases with the operating temperature and concentration of nanoparticles.

  4. Evaluation of Contact Heat Transfer Coefficient and Phase Transformation during Hot Stamping of a Hat-Type Part

    PubMed Central

    Kim, Heung-Kyu; Lee, Seong Hyeon; Choi, Hyunjoo

    2015-01-01

    Using an inverse analysis technique, the heat transfer coefficient on the die-workpiece contact surface of a hot stamping process was evaluated as a power law function of contact pressure. This evaluation was to determine whether the heat transfer coefficient on the contact surface could be used for finite element analysis of the entire hot stamping process. By comparing results of the finite element analysis and experimental measurements of the phase transformation, an evaluation was performed to determine whether the obtained heat transfer coefficient function could provide reasonable finite element prediction for workpiece properties affected by the hot stamping process. PMID:28788046

  5. Design principle for efficient charge separation at the donor-acceptor interface for high performance organic solar cell device

    NASA Astrophysics Data System (ADS)

    Nie, Wanyi; Gupta, Gautam; Crone, Brian; Wang, Hsing-Lin; Mohite, Aditya; MPA-11 Material synthesis and integrated device Team; MPA-chemistry Team

    2014-03-01

    The performance of donor (D) /acceptor (A) structure based organic electronic devices, such as solar cell, light emitting devices etc., relays on the charge transfer process at the interface dramatically. In organic solar cell, the photo-induced electron-hole pair is tightly bonded and will form a charge transfer (CT) state at the D/A interface after dissociation. There is a large chance for them to recombine through CT state and thus is a major loss that limit the overall performance. Here, we report three different strategies that allow us to completely suppress the exciplex (or charge transfer state) recombination between any D/A system. We observe that the photocurrent increases by 300% and the power conversion efficiency increases by 4-5 times simply by inserting a spacer layer in the form of an a) insulator b) Oliogomer or using a c) heavy atom at the donor-acceptor interface in a P3HT/C60 bilayer device. By using those different functional mono layers, we successfully suppressed the exciplex recombination in evidence of increased photocurrent and open circuit voltage. Moreover, these strategies are applicable universally to any donor-acceptor interface. And we demonstrated such strategies in a bulk-heterojunction device which improved the power conversion efficiency from 3.5% up to 4.6%.

  6. Effect of Hemoconcentration on Dural Sinus Computed Tomography Density in a Pediatric Population.

    PubMed

    Yurttutan, Nursel; Kizildag, Betul; Sarica, Mehmet Akif; Baykara, Murat

    2016-10-01

    Unenhanced brain computed tomography (CT) is inexpensive, easily available, and the first-choice imaging modality for patients presenting with various neurologic symptoms. Venous thrombosis is not rare in childhood, but diagnosis can be difficult. In some cases, only denser vessels can be used to highlight an issue. The aim of this study was to retrospectively evaluate the relationship between X-ray attenuation and hemoconcentration in a pediatric population. This study enrolled 99 pediatric patients who had been referred radiology department for unenhanced brain CT. Images were retrospectively evaluated for measurement of dural sinus densities from four distinct dural sinus locations. Correlation between mean Hounsfield unit (HU) values and hemoglobin/hematocrit (Hb/Htc) levels, as well as age and gender were further analyzed. There was a strong correlation between mean HU and Hb levels (r = 0.411; standard deviation: 0.001) and also between mean HU and Htc levels (r = 0.393; p < 0.001). According to the results of this study, the mean sinus density and H:H (HU:Htc) values were 44.06 HU and 1.19, respectively, in a normal pediatric group. In conclusion, before deciding between a diagnosis of thrombosis and a determination of normal findings during an evaluation of unenhanced CT in a pediatric population, radiologists should consider complete blood count results as well as H:H ratios. Georg Thieme Verlag KG Stuttgart · New York.

  7. HTC Vive MeVisLab integration via OpenVR for medical applications

    PubMed Central

    Egger, Jan; Gall, Markus; Wallner, Jürgen; Boechat, Pedro; Hann, Alexander; Li, Xing; Chen, Xiaojun; Schmalstieg, Dieter

    2017-01-01

    Virtual Reality, an immersive technology that replicates an environment via computer-simulated reality, gets a lot of attention in the entertainment industry. However, VR has also great potential in other areas, like the medical domain, Examples are intervention planning, training and simulation. This is especially of use in medical operations, where an aesthetic outcome is important, like for facial surgeries. Alas, importing medical data into Virtual Reality devices is not necessarily trivial, in particular, when a direct connection to a proprietary application is desired. Moreover, most researcher do not build their medical applications from scratch, but rather leverage platforms like MeVisLab, MITK, OsiriX or 3D Slicer. These platforms have in common that they use libraries like ITK and VTK, and provide a convenient graphical interface. However, ITK and VTK do not support Virtual Reality directly. In this study, the usage of a Virtual Reality device for medical data under the MeVisLab platform is presented. The OpenVR library is integrated into the MeVisLab platform, allowing a direct and uncomplicated usage of the head mounted display HTC Vive inside the MeVisLab platform. Medical data coming from other MeVisLab modules can directly be connected per drag-and-drop to the Virtual Reality module, rendering the data inside the HTC Vive for immersive virtual reality inspection. PMID:28323840

  8. Extraction of drainage networks from large terrain datasets using high throughput computing

    NASA Astrophysics Data System (ADS)

    Gong, Jianya; Xie, Jibo

    2009-02-01

    Advanced digital photogrammetry and remote sensing technology produces large terrain datasets (LTD). How to process and use these LTD has become a big challenge for GIS users. Extracting drainage networks, which are basic for hydrological applications, from LTD is one of the typical applications of digital terrain analysis (DTA) in geographical information applications. Existing serial drainage algorithms cannot deal with large data volumes in a timely fashion, and few GIS platforms can process LTD beyond the GB size. High throughput computing (HTC), a distributed parallel computing mode, is proposed to improve the efficiency of drainage networks extraction from LTD. Drainage network extraction using HTC involves two key issues: (1) how to decompose the large DEM datasets into independent computing units and (2) how to merge the separate outputs into a final result. A new decomposition method is presented in which the large datasets are partitioned into independent computing units using natural watershed boundaries instead of using regular 1-dimensional (strip-wise) and 2-dimensional (block-wise) decomposition. Because the distribution of drainage networks is strongly related to watershed boundaries, the new decomposition method is more effective and natural. The method to extract natural watershed boundaries was improved by using multi-scale DEMs instead of single-scale DEMs. A HTC environment is employed to test the proposed methods with real datasets.

  9. Antiproliferative effect of a food coloring on colon cancer cell line.

    PubMed

    Norizadeh Tazehkand, M

    2017-01-01

    4-MEI (4-Methylimidazole) is used as a chemical intermediate, crude material or component in the manufacture of pharmaceuticals, photographic and photothermographic chemicals, dyes and pigments and agricultural chemicals. 4-MEI is unintentionally found in our food. Caramel colour (which is the most used beverage colouring and food), dark beers and common brands of cola drinks may comprise more than 100 μg of this compound per 12-ounce serving. 4-MEI is widely used by people and colon cancer is common in our countries. So, it was decided to do in vitro analysis of anti-cancer effect of 4-MEI by MTT test using htc-116 cell line.In this study, mouse Htc-116 cell line was treated with 4-MEI concentrations of 300, 450, 600 and 750 µg/mL for 24 hours and 48 hours periods, after that antiproliferative effect of the 4-MEI was studied by MTT assay. In this study 4-MEI at highest concentration of 24h and at all concentration for 48 h treatment time significantly inhibited cell proliferation when it was compared to control. Also, exposing to the 4-MEI for 48 hours led to a decrease in cells proliferation by concentration dependent manner. This result showed that 4-MEI had anticancer effect in htc-116 cells. However, it has to be evaluated with different new studies (Tab. 1, Fig. 4, Ref. 19).

  10. HTC Vive MeVisLab integration via OpenVR for medical applications.

    PubMed

    Egger, Jan; Gall, Markus; Wallner, Jürgen; Boechat, Pedro; Hann, Alexander; Li, Xing; Chen, Xiaojun; Schmalstieg, Dieter

    2017-01-01

    Virtual Reality, an immersive technology that replicates an environment via computer-simulated reality, gets a lot of attention in the entertainment industry. However, VR has also great potential in other areas, like the medical domain, Examples are intervention planning, training and simulation. This is especially of use in medical operations, where an aesthetic outcome is important, like for facial surgeries. Alas, importing medical data into Virtual Reality devices is not necessarily trivial, in particular, when a direct connection to a proprietary application is desired. Moreover, most researcher do not build their medical applications from scratch, but rather leverage platforms like MeVisLab, MITK, OsiriX or 3D Slicer. These platforms have in common that they use libraries like ITK and VTK, and provide a convenient graphical interface. However, ITK and VTK do not support Virtual Reality directly. In this study, the usage of a Virtual Reality device for medical data under the MeVisLab platform is presented. The OpenVR library is integrated into the MeVisLab platform, allowing a direct and uncomplicated usage of the head mounted display HTC Vive inside the MeVisLab platform. Medical data coming from other MeVisLab modules can directly be connected per drag-and-drop to the Virtual Reality module, rendering the data inside the HTC Vive for immersive virtual reality inspection.

  11. Assessing the environmental impact of energy production from hydrochar generated via hydrothermal carbonization of food wastes.

    PubMed

    Berge, Nicole D; Li, Liang; Flora, Joseph R V; Ro, Kyoung S

    2015-09-01

    Although there are numerous studies suggesting hydrothermal carbonization is an environmentally advantageous process for transformation of wastes to value-added products, a systems level evaluation of the environmental impacts associated with hydrothermal carbonization and subsequent hydrochar combustion has not been conducted. The specific objectives of this work are to use a life cycle assessment approach to evaluate the environmental impacts associated with the HTC of food wastes and the subsequent combustion of the generated solid product (hydrochar) for energy production, and to understand how parameters and/or components associated with food waste carbonization and subsequent hydrochar combustion influence system environmental impact. Results from this analysis indicate that HTC process water emissions and hydrochar combustion most significantly influence system environmental impact, with a net negative GWP impact resulting for all evaluated substituted energy-sources except biomass. These results illustrate the importance of electricity production from hydrochar particularly when it is used to offset coal-based energy sources. HTC process water emissions result in a net impact to the environment, indicating a need for developing appropriate management strategies. Results from this analysis also highlight a need for additional exploration of liquid and gas-phase composition, a better understanding of how changes in carbonization conditions (e.g., reaction time and temperature) influence metal and nutrient fate, and the exploration of liquid-phase treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Volatilization of ethylene dibromide from water

    USGS Publications Warehouse

    Rathbun, R.E.; Tai, D.Y.

    1987-01-01

    Overall mass-transfer coefficients for the volatilization of ethylene dibromide from water were measured simultaneously with the oxygen absorption coefficient in a laboratory stirred tank. Coefficients were measured as a function of mixing conditions in the water for two windspeeds. The ethylene dibromide mass-transfer coefficient depended on windspeed; the ethylene dibromide liquid-film coefficient did not, in agreement with theory. A constant relation existed between the liquid-film coefficients for ethylene dibromide and oxygen.

  13. Study on heat transfer coefficients during cooling of PET bottles for food beverages

    NASA Astrophysics Data System (ADS)

    Liga, Antonio; Montesanto, Salvatore; Mannella, Gianluca A.; La Carrubba, Vincenzo; Brucato, Valerio; Cammalleri, Marco

    2016-08-01

    The heat transfer properties of different cooling systems dealing with Poly-Ethylene-Terephthalate (PET) bottles were investigated. The heat transfer coefficient (Ug) was measured in various fluid dynamic conditions. Cooling media were either air or water. It was shown that heat transfer coefficients are strongly affected by fluid dynamics conditions, and range from 10 W/m2 K to nearly 400 W/m2 K. PET bottle thickness effect on Ug was shown to become relevant under faster fluid dynamics regimes.

  14. Heat transfer coefficient distribution over the inconel plate cooled from high temperature by the array of water jets

    NASA Astrophysics Data System (ADS)

    Malinowski, Z.; Telejko, T.; Cebo-Rudnicka, A.; Szajding, A.; Rywotycki, M.; Hadała, B.

    2016-09-01

    The industrial rolling mills are equipped with systems for controlled water cooling of hot steel products. A cooling rate affects the final mechanical properties of steel which are strongly dependent on microstructure evolution processes. In case of water jets cooling the heat transfer boundary condition can be defined by the heat transfer coefficient. In the present study one and three dimensional heat conduction models have been employed in the inverse solution to heat transfer coefficient. The inconel plate has been heated to about 900oC and then cooled by one, two and six water jets. The plate temperature has been measured by 30 thermocouples. The heat transfer coefficient distributions at plate surface have been determined in time of cooling.

  15. The contact heat transfer between the heating plate and granular materials in rotary heat exchanger under overloaded condition

    NASA Astrophysics Data System (ADS)

    Duan, Luanfang; Qi, Chonggang; Ling, Xiang; Peng, Hao

    2018-03-01

    In the present work, the contact heat transfer between the granular materials and heating plates inside plate rotary heat exchanger (PRHE) was investigated. The heat transfer coefficient is dominated by the contact heat transfer coefficient at hot wall surface of the heating plates and the heat penetration inside the solid bed. A plot scale PRHE with a diameter of Do = 273 mm and a length of L = 1000 mm has been established. Quartz sand with dp = 2 mm was employed as the experimental material. The operational parameters were in the range of ω = 1 - 8 rpm, and F = 15, 20, 25, 30%, and the effect of these parameters on the time-average contact heat transfer coefficient was analyzed. The time-average contact heat transfer coefficient increases with the increase of rotary speed, but decreases with the increase of the filling degree. The measured data of time-average heat transfer coefficients were compared with theoretical calculations from Schlünder's model, a good agreement between the measurements and the model could be achieved, especially at a lower rotary speed and filling degree level. The maximum deviation between the calculated data and the experimental data is approximate 10%.

  16. Heat transfer coefficient as parameter describing ability of insulating liquid to heat transfer

    NASA Astrophysics Data System (ADS)

    Nadolny, Zbigniew; Gościński, Przemysław; Bródka, Bolesław

    2017-10-01

    The paper presents the results of the measurements of heat transfer coefficient of insulating liquids used in transformers. The coefficient describes an ability of the liquid to heat transport. On the basis of the coefficient, effectiveness of cooling system of electric power devices can be estimated. Following liquids were used for the measurements: mineral oil, synthetic ester and natural ester. It was assumed that surface heat load is about 2500 W·m-2, which is equal the load of transformer windings. A height of heat element was 1.6 m, because it makes possible steady distribution of temperature on its surface. The measurements of heat transfer coefficient was made as a function of various position of heat element (vertical, horizontal). In frame of horizontal position of heat element, three suppositions were analysed: top, bottom, and side.

  17. Experiment of flow regime map and local condensing heat transfer coefficients inside three dimensional inner microfin tubes

    NASA Astrophysics Data System (ADS)

    Du, Yang; Xin, Ming Dao

    1999-03-01

    This paper developed a new type of three dimensional inner microfin tube. The experimental results of the flow patterns for the horizontal condensation inside these tubes are reported in the paper. The flow patterns for the horizontal condensation inside the new made tubes are divided into annular flow, stratified flow and intermittent flow within the test conditions. The experiments of the local heat transfer coefficients for the different flow patterns have been systematically carried out. The experiments of the local heat transfer coefficients changing with the vapor dryness fraction have also been carried out. As compared with the heat transfer coefficients of the two dimensional inner microfin tubes, those of the three dimensional inner microfin tubes increase 47-127% for the annular flow region, 38-183% for the stratified flow and 15-75% for the intermittent flow, respectively. The enhancement factor of the local heat transfer coefficients is from 1.8-6.9 for the vapor dryness fraction from 0.05 to 1.

  18. Laser Measurement Of Convective-Heat-Transfer Coefficient

    NASA Technical Reports Server (NTRS)

    Porro, A. Robert; Hingst, Warren R.; Chriss, Randall M.; Seablom, Kirk D.; Keith, Theo G., Jr.

    1994-01-01

    Coefficient of convective transfer of heat at spot on surface of wind-tunnel model computed from measurements acquired by developmental laser-induced-heat-flux technique. Enables non-intrusive measurements of convective-heat-transfer coefficients at many points across surfaces of models in complicated, three-dimensional, high-speed flows. Measurement spot scanned across surface of model. Apparatus includes argon-ion laser, attenuator/beam splitter electronic shutter infrared camera, and subsystem.

  19. Determination of the diffusion coefficient and phase-transfer rate parameter in LaNi{sub 5} and MmNi{sub 3.6}Co{sub 0.8}Mn{sub 0.4}Al{sub 0.3} using microelectrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundqvist, A.; Lindbergh, G.

    1998-11-01

    A potential-step method for determining the diffusion coefficient and phase-transfer parameter in metal hydrides by using microelectrodes was investigated. It was shown that a large potential step is not enough to ensure a completely diffusion-limited mass transfer if a surface-phase transfer reaction takes place at a finite rate. It was shown, using a kinetic expression for the surface phase-transfer reaction, that the slope of the logarithm of the current vs. time curve will be constant both in the case of the mass-transfer limited by diffusion or by diffusion and a surface-phase transfer. The diffusion coefficient and phase-transfer rate parameter weremore » accurately determined for MmNi{sub 3.6}Co{sub 0.8}Mn{sub 0.4}Al{sub 0.3} using a fit to the whole transient. The diffusion coefficient was found to be (1.3 {+-} 0.3) {times} 10{sup {minus}13} m{sup 2}/s. The fit was good and showed that a pure diffusion model was not enough to explain the observed transient. The diffusion coefficient and phase-transfer rate parameter were also estimated for pure LaNi{sub 5}. A fit of the whole curve showed that neither a pure diffusion model nor a model including phase transfer could explain the whole transient.« less

  20. Vertical mass transfer in open channel flow

    USGS Publications Warehouse

    Jobson, Harvey E.

    1968-01-01

    The vertical mass transfer coefficient and particle fall velocity were determined in an open channel shear flow. Three dispersants, dye, fine sand and medium sand, were used with each of three flow conditions. The dispersant was injected as a continuous line source across the channel and downstream concentration profiles were measured. From these profiles along with the measured velocity distribution both the vertical mass transfer coefficient and the local particle fall velocity were determined.The effects of secondary currents on the vertical mixing process were discussed. Data was taken and analyzed in such a way as to largely eliminate the effects of these currents on the measured values. A procedure was developed by which the local value of the fall velocity of sand sized particles could be determined in an open channel flow. The fall velocity of the particles in the turbulent flow was always greater than their fall velocity in quiescent water. Reynolds analogy between the transfer of momentum and marked fluid particles was further substantiated. The turbulent Schmidt number was shown to be approximately 1.03 for an open channel flow with a rough boundary. Eulerian turbulence measurements were not sufficient to predict the vertical transfer coefficient. Vertical mixing of sediment is due to three semi-independent processes. These processes are: secondary currents, diffusion due to tangential velocity fluctuations and diffusion due to the curvature of the fluid particle path lines. The diffusion coefficient due to tangential velocity fluctuations is approximately proportional to the transfer coefficient of marked fluid particles. The proportionality constant is less than or equal to 1.0 and decreases with increasing particle size. The diffusion coefficient due to the curvature of the fluid particle path lines is not related to the diffusion coefficient for marked fluid particles and increases with particle size, at least for sediment particles in the sand size range. The total sediment transfer coefficient is equal to the sum of the coefficient due to tangential velocity fluctuations and the coefficient due to the curvature of the fluid particle path lines. A numerical solution to the conservation of mass equation is given. The effects of the transfer coefficient, fall velocity and bed conditions on the predicted concentration profiles are illustrated.

  1. Investigation on the heat transfer characteristics during flow boiling of liquefied natural gas in a vertical micro-fin tube

    NASA Astrophysics Data System (ADS)

    Xu, Bin; Shi, Yumei; Chen, Dongsheng

    2014-03-01

    This paper presents an experimental investigation on the heat transfer characteristics of liquefied natural gas flow boiling in a vertical micro-fin tube. The effect of heat flux, mass flux and inlet pressure on the flow boiling heat transfer coefficients was analyzed. The Kim, Koyama, and two kinds of Wellsandt correlations with different Ftp coefficients were used to predict the flow boiling heat transfer coefficients. The predicted results showed that the Koyama correlation was the most accurate over the range of experimental conditions.

  2. Measurement of airfoil heat transfer coefficients on a turbine stage

    NASA Technical Reports Server (NTRS)

    Dring, R. P.; Blair, M. F.

    1984-01-01

    The primary basis for heat transfer analysis of turbine airfoils is experimental data obtained in linear cascades. A detailed set of heat transfer coefficients was obtained along the midspan of a stator and a rotor in a rotating turbine stage. The data are to be compared to standard analyses of blade boundary layer heat transfer. A detailed set of heat transfer coefficients was obtained along the midspan of a stator located in the wake of a full upstream turbine stage. Two levels of inlet turbulence (1 and 10 percent) were used. The analytical capability will be examined to improve prediction of the experimental data.

  3. Post-Dryout Heat Transfer to a Refrigerant Flowing in Horizontal Evaporator Tubes

    NASA Astrophysics Data System (ADS)

    Mori, Hideo; Yoshida, Suguru; Kakimoto, Yasushi; Ohishi, Katsumi; Fukuda, Kenichi

    Studies of the post-dryout heat transfer were made based on the experimental data for HFC-134a flowing in horizontal smooth and spiral1y grooved (micro-fin) tubes and the characteristics of the post-dryout heat transfer were c1arified. The heat transfer coefficient at medium and high mass flow rates in the smooth tube was lower than the single-phase heat transfer coefficient of the superheated vapor flow, of which mass flow rate was given on the assumption that the flow was in a thermodynamic equilibrium. A prediction method of post-dryout heat transfer coefficient was developed to reproduce the measurement satisfactorily for the smooth tube. The post dryout heat transfer in the micro-fin tube can be regarded approximately as a superheated vapor single-phase heat transfer.

  4. Isotopic disproportionation during hydrogen isotopic analysis of nitrogen-bearing organic compounds

    USGS Publications Warehouse

    Nair, Sreejesh; Geilmann, Heike; Coplen, Tyler B.; Qi, Haiping; Gehre, Matthias; Schimmelmann, Arndt; Brand, Willi A.

    2015-01-01

    Rationale High-precision hydrogen isotope ratio analysis of nitrogen-bearing organic materials using high-temperature conversion (HTC) techniques has proven troublesome in the past. Formation of reaction products other than molecular hydrogen (H2) has been suspected as a possible cause of incomplete H2 yield and hydrogen isotopic fractionation. Methods The classical HTC reactor setup and a modified version including elemental chromium, both operated at temperatures in excess of 1400 °C, have been compared using a selection of nitrogen-bearing organic compounds, including caffeine. A focus of the experiments was to avoid or suppress hydrogen cyanide (HCN) formation and to reach quantitative H2 yields. The technique also was optimized to provide acceptable sample throughput. Results The classical HTC reaction of a number of selected compounds exhibited H2 yields from 60 to 90 %. Yields close to 100 % were measured for the experiments with the chromium-enhanced reactor. The δ2H values also were substantially different between the two types of experiments. For the majority of the compounds studied, a highly significant relationship was observed between the amount of missing H2and the number of nitrogen atoms in the molecules, suggesting the pyrolytic formation of HCN as a byproduct. A similar linear relationship was found between the amount of missing H2 and the observed hydrogen isotopic result, reflecting isotopic fractionation. Conclusions The classical HTC technique to produce H2 from organic materials using high temperatures in the presence of glassy carbon is not suitable for nitrogen-bearing compounds. Adding chromium to the reaction zone improves the yield to 100 % in most cases. The initial formation of HCN is accompanied by a strong hydrogen isotope effect, with the observed hydrogen isotope results on H2 being substantially shifted to more negative δ2H values. The reaction can be understood as an initial disproportionation leading to H2 and HCN with the HCN-hydrogen systematically enriched in 2H by more than 50 ‰. In the reaction of HCN with chromium, H2 and chromium-containing solid residues are formed quantitatively.

  5. Same day HIV diagnosis and antiretroviral therapy initiation affects retention in Option B+ prevention of mother-to-child transmission services at antenatal care in Zomba District, Malawi.

    PubMed

    Chan, Adrienne K; Kanike, Emmanuel; Bedell, Richard; Mayuni, Isabel; Manyera, Ruth; Mlotha, William; Harries, Anthony D; van Oosterhout, Joep J; van Lettow, Monique

    2016-01-01

    Data from the Option B+ prevention of mother-to-child transmission (PMTCT) program in Malawi show considerable variation between health facilities in retention on antiretroviral therapy (ART). In a programmatic setting, we studied whether the "model of care," based on the degree of integration of antenatal care (ANC), HIV testing and counselling (HTC) and ART service provision-influenced uptake of and retention on ART. We conducted a retrospective cohort study of pregnant women seeking ANC at rural primary health facilities in Zomba District, Malawi. Data were extracted from standardized national ANC registers, ART registers and ART master cards. The "model of care" of Option B+ service delivery was determined at each health facility, based on the degree of integration of ANC, HTC and ART. Full integration (Model 1) of HTC and ART initiation at ANC was compared with integration of HTC only into ANC services (Model 2) with subsequent referral to an existing ART clinic for treatment initiation. A total of 10,528 women were newly registered at ANC between October 2011 and March 2012 in 23 rural health facilities (12 were Model 1 and 11 Model 2). HIV status was ascertained in 8,572 (81%) women. Among 914/8,572 (9%) HIV-positive women enrolling at ANC, 101/914 (11%) were already on ART; of those not on treatment, 456/813 (56%) were started on ART. There was significantly higher ART uptake in Model 1 compared with Model 2 sites (63% vs. 51%; p=0.001), but significantly lower ART retention in Model 1 compared with Model 2 sites (79% vs. 87%; p=0.02). Multivariable analysis showed that initiation of ART on the same day as HIV diagnosis, but not model of care, was independently associated with reduced retention in the first six months (adjusted odds ratio 2.27; 95% CI: 1.34-3.85; p=0.002). HIV diagnosis and treatment on the same day was associated with reduced retention on ART, independent of the level of PMTCT service integration at ANC.

  6. Tonian paleomagnetism of the red beds of Madiyi Formation, lower Banxi Group in South China: implications for pre-Sturtian climate, Rodinia reconstruction and true polar wander

    NASA Astrophysics Data System (ADS)

    Hanbiao, X.; Zhang, S.; Xiao, Q.; Li, H.; Chang, L.; Fu, H.; Liu, R.

    2017-12-01

    We present a new Tonian paleomagnetic pole from the red beds of ca. 810 Ma Madiyi Formation, lower Banxi Group in the central South China Block (SCB). Detailed thermal demagnetization reveals two distinct magnetic components among the samples. A low temperature component (LTC), removed from almost all the samples below 580°C, yielded a paleopole at 68.0°N, 211.7°E (A95=1.9) that is close to the pole of late Jurassic. The high temperature component (HTC), isolated between 580-690°C, gave a mean direction of D=310.0°, I=57.4°, α95=3.7 (108 samples of 13 sites) after bedding correction, corresponding to a paleomagnetic pole at 47.6°N, 46.7°E (A95=5.6°). The HTC passed a reversal test on 95% and 99% confidence level. Directional distribution of the HTC show significant elongation which may indicate inclination shallowing, and the inclination was corrected to 75.1° using E/I technique, corresponding to a paleolatitude at 60.8±3.4° of research area. The paleopole calculated from the E/I-corrected HTC is at 44.8°N, 80.2°E (A95=3.4°), being significantly distinct from any younger poles of the SCB. This new pole plus existing high quality paleomagnetic poles from the SCB demonstrate that the SCB experienced a polar-equatorial region drifting tendency from 825 Ma to Cambrian. The high-paleolatitude red beds rather than glacial sediments deposited in the SCB, combined with coeval widespread evaporative in other continents, possibly suggest pre-Cryogenian global greenhouse climate. In our reconstruction at 800 Ma, the SCB was placed on the northwest periphery of Rodinia, with its western margin adjacent to the northern India, rather than occupying a central position of Rodinia. The distribution of 825-750 Ma poles of the SCB, East Svalbard, Australia, Laurentia, India along a great arc may be associated with true polar wander around 800 Ma.

  7. Same day ART initiation versus clinic-based pre-ART assessment and counselling for individuals newly tested HIV-positive during community-based HIV testing in rural Lesotho - a randomized controlled trial (CASCADE trial).

    PubMed

    Labhardt, Niklaus Daniel; Ringera, Isaac; Lejone, Thabo Ishmael; Masethothi, Phofu; Thaanyane, T'sepang; Kamele, Mashaete; Gupta, Ravi Shankar; Thin, Kyaw; Cerutti, Bernard; Klimkait, Thomas; Fritz, Christiane; Glass, Tracy Renée

    2016-04-14

    Achievement of the UNAIDS 90-90-90 targets in Sub-Sahara Africa is challenged by a weak care-cascade with poor linkage to care and retention in care. Community-based HIV testing and counselling (HTC) is widely used in African countries. However, rates of linkage to care and initiation of antiretroviral therapy (ART) in individuals who tested HIV-positive are often very low. A frequently cited reason for non-linkage to care is the time-consuming pre-ART assessment often requiring several clinic visits before ART-initiation. This two-armed open-label randomized controlled trial compares in individuals tested HIV-positive during community-based HTC the proposition of same-day community-based ART-initiation to the standard of care pre-ART assessment at the clinic. Home-based HTC campaigns will be conducted in catchment areas of six clinics in rural Lesotho. Households where at least one individual tested HIV positive will be randomized. In the standard of care group individuals receive post-test counselling and referral to the nearest clinic for pre-ART assessment and counselling. Once they have started ART the follow-up schedule foresees monthly clinic visits. Individuals randomized to the intervention group receive on the spot point-of-care pre-ART assessment and adherence counselling with the proposition to start ART that same day. Once they have started ART, follow-up clinic visits will be less frequent. First primary outcome is linkage to care (individual presents at the clinic at least once within 3 months after the HIV test). The second primary outcome is viral suppression 12 months after enrolment in the study. We plan to enrol a minimum of 260 households with 1:1 allocation and parallel assignment into both arms. This trial will show if in individuals tested HIV-positive during community-based HTC campaigns the proposition of same-day ART initiation in the community, combined with less frequent follow-up visits at the clinic could be a pragmatic approach to improve the care cascade in similar settings. NCT02692027 , registered February 21, 2016.

  8. Application of the two-film model to the volatilization of acetone and t-butyl alcohol from water as a function of temperature

    USGS Publications Warehouse

    Rathbun, R.E.; Tai, D.Y.

    1988-01-01

    The two-film model is often used to describe the volatilization of organic substances from water. This model assumes uniformly mixed water and air phases separated by thin films of water and air in which mass transfer is by molecular diffusion. Mass-transfer coefficients for the films, commonly called film coefficients, are related through the Henry's law constant and the model equation to the overall mass-transfer coefficient for volatilization. The films are modeled as two resistances in series, resulting in additive resistances. The two-film model and the concept of additivity of resistances were applied to experimental data for acetone and t-butyl alcohol. Overall mass-transfer coefficients for the volatilization of acetone and t-butyl alcohol from water were measured in the laboratory in a stirred constant-temperature bath. Measurements were completed for six water temperatures, each at three water mixing conditions. Wind-speed was constant at about 0.1 meter per second for all experiments. Oxygen absorption coefficients were measured simultaneously with the measurement of the acetone and t-butyl alcohol mass-transfer coefficients. Gas-film coefficients for acetone, t-butyl alcohol, and water were determined by measuring the volatilization fluxes of the pure substances over a range of temperatures. Henry's law constants were estimated from data from the literature. The combination of high resistance in the gas film for solutes with low values of the Henry's law constants has not been studied previously. Calculation of the liquid-film coefficients for acetone and t-butyl alcohol from measured overall mass-transfer and gas-film coefficients, estimated Henry's law constants, and the two-film model equation resulted in physically unrealistic, negative liquid-film coefficients for most of the experiments at the medium and high water mixing conditions. An analysis of the two-film model equation showed that when the percentage resistance in the gas film is large and the gas-film resistance approaches the overall resistance in value, the calculated liquid-film coefficient becomes extremely sensitive to errors in the Henry's law constant. The negative coefficients were attributed to this sensitivity and to errors in the estimated Henry's law constants. Liquid-film coefficients for the absorption of oxygen were correlated with the stirrer Reynolds number and the Schmidt number. Application of this correlation with the experimental conditions and a molecular-diffusion coefficient adjustment resulted in values of the liquid-film coefficients for both acetone and t-butyl alcohol within the range expected for all three mixing conditions. Comparison of Henry's law constants calculated from these film coefficients and the experimental data with the constants calculated from literature data showed that the differences were small relative to the errors reported in the literature as typical for the measurement or estimation of Henry's law constants for hydrophilic compounds such as ketones and alcohols. Temperature dependence of the mass-transfer coefficients was expressed in two forms. The first, based on thermodynamics, assumed the coefficients varied as the exponential of the reciprocal absolute temperature. The second empirical approach assumed the coefficients varied as the exponential of the absolute temperature. Both of these forms predicted the temperature dependence of the experimental mass-transfer coefficients with little error for most of the water temperature range likely to be found in streams and rivers. Liquid-film and gas-film coefficients for acetone and t-butyl alcohol were similar in value. However, depending on water mixing conditions, overall mass-transfer coefficients for acetone were from two to four times larger than the coefficients for t-butyl alcohol. This difference in behavior of the coefficients resulted because the Henry's law constant for acetone was about three times larger than that of

  9. Air sparging: Air-water mass transfer coefficients

    NASA Astrophysics Data System (ADS)

    Braida, Washington J.; Ong, Say Kee

    1998-12-01

    Experiments investigating the mass transfer of several dissolved volatile organic compounds (VOCs) across the air-water interface were conducted using a single-air- channel air-sparging system. Three different porous media were used in the study. Air velocities ranged from 0.2 cm s-1 to 2.5 cm s-1. The tortuosity factor for each porous medium and the air-water mass transfer coefficients were estimated by fitting experimental data to a one-dimensional diffusion model. The estimated mass transfer coefficients KG ranged from 1.79 × 10-3 cm min-1 to 3.85 × 10-2 cm min-1. The estimated lumped gas phase mass transfer coefficients KGa were found to be directly related to the air diffusivity of the VOC, air velocity, and particle size, and inversely related to the Henry's law constant of the VOCs. Of the four parameters investigated, the parameter that controlled or had a dominant effect on the lumped gas phase mass transfer coefficient was the air diffusivity of the VOC. Two empirical models were developed by correlating the Damkohler and the modified air phase Sherwood numbers with the air phase Peclet number, Henry's law constant, and the reduced mean particle size of porous media. The correlation developed in this study may be used to obtain better predictions of mass transfer fluxes for field conditions.

  10. Experimental determination of heat transfer coefficients in roll bite and air cooling for computer simulations of 1100 MPa carbon steel rolling

    NASA Astrophysics Data System (ADS)

    Leinonen, Olli; Ilmola, Joonas; Seppälä, Oskari; Pohjonen, Aarne; Paavola, Jussi; Koskenniska, Sami; Larkiola, Jari

    2018-05-01

    In modeling of hot rolling pass schedules the heat transfer phenomena have to be known. Radiation to ambient, between rolls and a steel slab as well as heat transfer in contacts must be considered to achieve accurate temperature distribution and thereby accurate material behavior in simulations. Additional heat is generated by friction between the slab and the work roll and by plastic deformation. These phenomena must be taken into account when the effective heat transfer coefficient is determined from experimental data. In this paper we determine the effective heat transfer coefficient at the contact interface and emissivity factor of slab surface for 1100MPa strength carbon steel for hot rolling simulations. Experimental pilot rolling test were carried out and slab temperatures gathered right below the interface and at the mid thickness of the slab. Emissivity factor tests were carried out in the same manner but without rolling. Experimental data is utilized to derive contact heat transfer coefficient at the interface and emissivity factor of slab surface. Pilot rolling test is reproduced in FE-analysis to further refine the heat transfer coefficient and emissivity factor. Material mechanical properties at rolling temperatures were determined by Gleeble™ thermo-mechanical simulator and IDS thermodynamic-kinetic-empirical software.

  11. Heat transfer and pressure drop characteristics of a plate heat exchanger using water based Al2O3 nanofluid for 30° and 60° chevron angles

    NASA Astrophysics Data System (ADS)

    Elias, M. M.; Saidur, R.; Ben-Mansour, R.; Hepbasli, A.; Rahim, N. A.; Jesbains, K.

    2018-04-01

    Nanofluid is a new class of engineering fluid that has good heat transfer characteristics which is essential to increase the heat transfer performance in various engineering applications such as heat exchangers and cooling of electronics. In this study, experiments were conducted to compare the heat transfer performance and pressure drop characteristics in a plate heat exchanger (PHE) for 30° and 60° chevron angles using water based Al2O3 nanofluid at the concentrations from 0 to 0.5 vol.% for different Reynolds numbers. The thermo-physical properties has been determined and presented in this paper. At 0.5 vol% concentration, the maximum heat transfer coefficient, the overall heat transfer coefficient and the heat transfer rate for 60° chevron angle have attained a higher percentage of 15.14%, 7.8% and 15.4%, respectively in comparison with the base fluid. Consequently, when the volume concentration or Reynolds number increases, the heat transfer coefficient and the overall heat transfer coefficient as well as the heat transfer rate of the PHE (Plate Heat Exchangers) increases respectively. Similarly, the pressure drop increases with the volume concentration. 60° chevron angle showed better performance in comparison with 30° chevron angle.

  12. Development of a laser-induced heat flux technique for measurement of convective heat transfer coefficients in a supersonic flowfield

    NASA Technical Reports Server (NTRS)

    Porro, A. Robert; Keith, Theo G., Jr.; Hingst, Warren R.; Chriss, Randall M.; Seablom, Kirk D.

    1991-01-01

    A technique is developed to measure the local convective heat transfer coefficient on a model surface in a supersonic flow field. The technique uses a laser to apply a discrete local heat flux at the model test surface, and an infrared camera system determines the local temperature distribution due to heating. From this temperature distribution and an analysis of the heating process, a local convective heat transfer coefficient is determined. The technique was used to measure the load surface convective heat transfer coefficient distribution on a flat plate at nominal Mach numbers of 2.5, 3.0, 3.5, and 4.0. The flat plate boundary layer initially was laminar and became transitional in the measurement region. The experimental results agreed reasonably well with theoretical predictions of convective heat transfer of flat plate laminar boundary layers. The results indicate that this non-intrusive optical measurement technique has the potential to obtain high quality surface convective heat transfer measurements in high speed flowfields.

  13. Genotoxic evaluation of an industrial effluent from an oil refinery using plant and animal bioassays.

    PubMed

    Rodrigues, Fernando Postalli; Angeli, José Pedro Friedmann; Mantovani, Mário Sérgio; Guedes, Carmen Luisa Barbosa; Jordão, Berenice Quinzani

    2010-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are genotoxic chemicals commonly found in effluents from oil refineries. Bioassays using plants and cells cultures can be employed for assessing environmental safety and potential genotoxicity. In this study, the genotoxic potential of an oil refinery effluent was analyzed by means of micronucleus (MN) testing of Alium cepa, which revealed no effect after 24 h of treatment. On the other hand, primary lesions in the DNA of rat (Rattus norvegicus) hepatoma cells (HTC) were observed through comet assaying after only 2 h of exposure. On considering the capacity to detect DNA damage of a different nature and of these cells to metabolize xenobiotics, we suggest the association of the two bioassays with these cell types, plant (Allium cepa) and mammal (HTC) cells, for more accurately assessing genotoxicity in environmental samples.

  14. Bone disease in patients awaiting liver transplantation. Has the situation improved in the last two decades?

    PubMed

    Monegal, Ana; Navasa, Miquel; Peris, Pilar; Colmenero, Jordi; Cuervo, Andrea; Muxí, Africa; Gifre, Laia; Guañabens, Núria

    2013-12-01

    In recent years, there has been speculation about the possibility of a reduction in the incidence of fractures after liver transplantation (LT) because of changes in the characteristics of candidates and the use of different immunosuppressive therapies. We analyzed the characteristics of LT candidates (CTC) and compared them with historical data from a group of LT candidate patients (HTC). Data from 60 CTC patients consecutively included in a screening program of metabolic bone disease were compared with data from 60 HTC patients prospectively evaluated between 1992 and 1993. In all patients, we analyzed the clinical and laboratory characteristics, bone mineral density (BMD) dual-energy X-ray absorptiometry, and skeletal fractures. Patients in the CTC group were older than patients in the HTC group. The CTC group had lower femoral neck T scores. No differences were observed between groups in the proportion of patients with osteoporosis (22 vs. 30 %, p = ns) or fractures (36 vs. 33 %, p = ns). The percentage of patients with normal BMD decreased from 38 to 20 %. 25(OH)D values were low in both groups. Only 7.5 % of the CTC patients received calcium and/or vitamin D supplementation. The prevalence of fractures among CTC patients was similar to that seen two decades ago. At present, candidates for LT are older and have lower femoral bone mass. Vitamin D deficiency remains frequent; however, calcium and/or vitamin D supplementation is uncommon.

  15. Factor for felons: how can we provide haemophilia care to the incarcerated?

    PubMed

    Lambing, A; Kachalsky, E; Mueller, L M; Kuriakose, P

    2015-11-01

    In 2011, 6.98-million offenders were documented in the adult correctional system, with state operating costs designated 12% towards medical care ($11.97 day per inmate) for the general population. Common co-existing health problems identified are: arthritis (13%), hypertension (11%), asthma (10%) and heart problems (6%). Less than 5% of inmates have health issues related to cancer, diabetes, liver or renal problems and communicable diseases. The leading cause of death is suicide (33.2%), followed by heart disease (26.1%). Despite these statistics quality is lacking. Given these statistics, one would expect that a small proportion of patients from Hemophilia Treatment Center (HTC) will spend some time within the justice system. Currently there are no data addressing haemophilia care needs while incarcerated. This article will review the current health care issues in the adult correctional system. Additionally, six case reports of incarcerated haemophiliacs will be highlighted exploring the successes and challenges with maintaining haemophilia care addressing the priority of meeting the haemophilia care needs verses the penal system regulations. It can be expected that at some point, the HTC will experience a patient incarcerated for some period of time. The HTC will continue to advocate for their patient within this system, despite the many challenges faced. Despite the challenges outlined, ongoing communication and education with the correctional system, education of the medical personnel and prison personnel remains the priority as we advocate for our patients. Continued strategies in these areas are paramount. © 2015 John Wiley & Sons Ltd.

  16. Heat transfer to horizontal tubes in a pilot-scale fluidized-bed combustor burning low-rank coals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grewal, N.S.; Goblirsch, G.

    Experimental data are obtained for the heat transfer coefficient between immersed horizontal tube bundles and an atmospheric-fluidized-bed combustor burning low-rank coals. Silica sand and limestone are used as bed material. The tests are conducted, with and without limestone addition and ash recycle, at average bed temperatures ranging from 1047 to 1125 K, superficial fluidizing velocity of 1.66 to 2.04 m/s, and excess air levels of 15 to 40 percent. The experimental data are examined in the light of the existing correlations for the heat transfer coefficient. The predicted values of heat transfer coefficient from the correlations proposed by Grewal andmore » Bansal et al. are found to be within + or - 25 percent of the experimental values of heat transfer coefficient, when the contribution due to radiation is also included.« less

  17. Study of a high performance evaporative heat transfer surface

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.; Hamasaki, R. H.

    1977-01-01

    An evaporative surface is described for heat pipes and other two-phase heat transfer applications that consists of a hybrid composition of V-grooves and capillary wicking. Characteristics of the surface include both a high heat transfer coefficient and high heat flux capability relative to conventional open-faced screw thread surfaces. With a groove density of 12.6 cm/1 and ammonia working fluid, heat transfer coefficients in the range of 1 to 2 W/sq cm have been measured along with maximum heat flux densities in excess of 20 W/sq cm. A peak heat transfer coefficient in excess of 2.3 W/sq cm was measured with a 37.8 cm/1 hybrid surface.

  18. Numerical Simulation of Internal Heat Transfer Phenomena Occurring During De-Icing of Aircraft Components

    NASA Technical Reports Server (NTRS)

    DeWitt, Keneth J.

    1996-01-01

    An experimental study to determine the convective heat transfer coefficient from castings made from ice-roughened plates is reported. A corresponding topic, 'Measurements of the Convective Heat Transfer Coefficient from Ice Roughened Surfaces in Parallel and Accelerated Flows,' is presented.

  19. Evaporation heat transfer of carbon dioxide at low temperature inside a horizontal smooth tube

    NASA Astrophysics Data System (ADS)

    Yoon, Jung-In; Son, Chang-Hyo; Jung, Suk-Ho; Jeon, Min-Ju; Yang, Dong-Il

    2017-05-01

    In this paper, the evaporation heat transfer coefficient of carbon dioxide at low temperature of -30 to -20 °C in a horizontal smooth tube was investigated experimentally. The test devices consist of mass flowmeter, pre-heater, magnetic gear pump, test section (evaporator), condenser and liquid receiver. Test section is made of cooper tube. Inner and outer diameter of the test section is 8 and 9.52 mm, respectively. The experiment is conducted at mass fluxes from 100 to 300 kg/m2 s, saturation temperature from -30 to -20 °C. The main results are summarized as follows: In case that the mass flux of carbon dioxide is 100 kg/m2 s, the evaporation heat transfer coefficient is almost constant regardless of vapor quality. In case of 200 and 300 kg/m2 s, the evaporation heat transfer coefficient increases steadily with increasing vapor quality. For the same mass flux, the evaporation heat transfer coefficient increases as the evaporation temperature of the refrigerant decreases. In comparison of heat transfer correlations with the experimental result, the evaporation heat transfer correlations do not predict them exactly. Therefore, more accurate heat transfer correlation than the previous one is required.

  20. System and method of active vibration control for an electro-mechanically cooled device

    DOEpatents

    Lavietes, Anthony D.; Mauger, Joseph; Anderson, Eric H.

    2000-01-01

    A system and method of active vibration control of an electro-mechanically cooled device is disclosed. A cryogenic cooling system is located within an environment. The cooling system is characterized by a vibration transfer function, which requires vibration transfer function coefficients. A vibration controller generates the vibration transfer function coefficients in response to various triggering events. The environments may differ by mounting apparatus, by proximity to vibration generating devices, or by temperature. The triggering event may be powering on the cooling system, reaching an operating temperature, or a reset action. A counterbalance responds to a drive signal generated by the vibration controller, based on the vibration signal and the vibration transfer function, which adjusts vibrations. The method first places a cryogenic cooling system within a first environment and then generates a first set of vibration transfer function coefficients, for a vibration transfer function of the cooling system. Next, the cryogenic cooling system is placed within a second environment and a second set of vibration transfer function coefficients are generated. Then, a counterbalance is driven, based on the vibration transfer function, to reduce vibrations received by a vibration sensitive element.

  1. An experimental and numerical study of endwall heat transfer in a turbine blade cascade including tangential heat conduction analysis

    NASA Astrophysics Data System (ADS)

    Ratto, Luca; Satta, Francesca; Tanda, Giovanni

    2018-06-01

    This paper presents an experimental and numerical investigation of heat transfer in the endwall region of a large scale turbine cascade. The steady-state liquid crystal technique has been used to obtain the map of the heat transfer coefficient for a constant heat flux boundary condition. In the presence of two- and three-dimensional flows with significant spatial variations of the heat transfer coefficient, tangential heat conduction could lead to error in the heat transfer coefficient determination, since local heat fluxes at the wall-to-fluid interface tend to differ from point to point and surface temperatures to be smoothed out, thus making the uniform-heat-flux boundary condition difficult to be perfectly achieved. For this reason, numerical simulations of flow and heat transfer in the cascade including the effect of tangential heat conduction inside the endwall have been performed. The major objective of numerical simulations was to investigate the influence of wall heat conduction on the convective heat transfer coefficient determined during a nominal iso-flux heat transfer experiment and to interpret possible differences between numerical and experimental heat transfer results. Results were presented and discussed in terms of local Nusselt number and a convenient wall heat flux function for two values of the Reynolds number (270,000 and 960,000).

  2. Aerodynamic Heating Computations for Projectiles. Volume 1. In-Depth Heat Conduction Modifications to the ABRES Shape Change Code (BRLASCC)

    DTIC Science & Technology

    1984-06-01

    preceding the corresponding pressure group of the surface thermochemistry deck as described below. The temperature entries within each section must be... pressure group the transfer coefficient values will be ordered. Within each transfer coefficient section, ablation rate entries need not he ordered in any...may not exceed 5 (and may be only I); the number of transfer coefficient values in each pressure group may not exceed 5 but may be only 1. If no

  3. A fluid-solid coupling simulation method for convection heat transfer coefficient considering the under-vehicle condition

    NASA Astrophysics Data System (ADS)

    Tian, C.; Weng, J.; Liu, Y.

    2017-11-01

    The convection heat transfer coefficient is one of the evaluation indexes of the brake disc performance. The method used in this paper to calculate the convection heat transfer coefficient is a fluid-solid coupling simulation method, because the calculation results through the empirical formula method have great differences. The model, including a brake disc, a car body, a bogie and flow field, was built, meshed and simulated in the software FLUENT. The calculation models were K-epsilon Standard model and Energy model. The working condition of the brake disc was considered. The coefficient of various parts can be obtained through the method in this paper. The simulation result shows that, under 160 km/h speed, the radiating ribs have the maximum convection heat transfer coefficient and the value is 129.6W/(m2·K), the average coefficient of the whole disc is 100.4W/(m2·K), the windward of ribs is positive-pressure area and the leeward of ribs is negative-pressure area, the maximum pressure is 2663.53Pa.

  4. An Efficient Non-iterative Bulk Parametrization of Surface Fluxes for Stable Atmospheric Conditions Over Polar Sea-Ice

    NASA Astrophysics Data System (ADS)

    Gryanik, Vladimir M.; Lüpkes, Christof

    2018-02-01

    In climate and weather prediction models the near-surface turbulent fluxes of heat and momentum and related transfer coefficients are usually parametrized on the basis of Monin-Obukhov similarity theory (MOST). To avoid iteration, required for the numerical solution of the MOST equations, many models apply parametrizations of the transfer coefficients based on an approach relating these coefficients to the bulk Richardson number Rib. However, the parametrizations that are presently used in most climate models are valid only for weaker stability and larger surface roughnesses than those documented during the Surface Heat Budget of the Arctic Ocean campaign (SHEBA). The latter delivered a well-accepted set of turbulence data in the stable surface layer over polar sea-ice. Using stability functions based on the SHEBA data, we solve the MOST equations applying a new semi-analytic approach that results in transfer coefficients as a function of Rib and roughness lengths for momentum and heat. It is shown that the new coefficients reproduce the coefficients obtained by the numerical iterative method with a good accuracy in the most relevant range of stability and roughness lengths. For small Rib, the new bulk transfer coefficients are similar to the traditional coefficients, but for large Rib they are much smaller than currently used coefficients. Finally, a possible adjustment of the latter and the implementation of the new proposed parametrizations in models are discussed.

  5. CFD simulation of simultaneous monotonic cooling and surface heat transfer coefficient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihálka, Peter, E-mail: usarmipe@savba.sk; Matiašovský, Peter, E-mail: usarmat@savba.sk

    The monotonic heating regime method for determination of thermal diffusivity is based on the analysis of an unsteady-state (stabilised) thermal process characterised by an independence of the space-time temperature distribution on initial conditions. At the first kind of the monotonic regime a sample of simple geometry is heated / cooled at constant ambient temperature. The determination of thermal diffusivity requires the determination rate of a temperature change and simultaneous determination of the first eigenvalue. According to a characteristic equation the first eigenvalue is a function of the Biot number defined by a surface heat transfer coefficient and thermal conductivity ofmore » an analysed material. Knowing the surface heat transfer coefficient and the first eigenvalue the thermal conductivity can be determined. The surface heat transport coefficient during the monotonic regime can be determined by the continuous measurement of long-wave radiation heat flow and the photoelectric measurement of the air refractive index gradient in a boundary layer. CFD simulation of the cooling process was carried out to analyse local convective and radiative heat transfer coefficients more in detail. Influence of ambient air flow was analysed. The obtained eigenvalues and corresponding surface heat transfer coefficient values enable to determine thermal conductivity of the analysed specimen together with its thermal diffusivity during a monotonic heating regime.« less

  6. The augmentation of heat transfer in a pipe flow using a swirling perforated twisted (SPT) tape insert

    NASA Astrophysics Data System (ADS)

    Ahmad, Shahrokh; Oishe, Sadia Noon; Rahman, Md. Lutfor

    2017-12-01

    The purpose of this research work is to increase the heat transfer coefficient by operating the heat exchangers at smaller revolution per minute. This signifies an achievement of reduction of pressure drop corresponding to less operating cost. This study has used two types of SPT tape insert to observe the various heat transfer coefficient, heat transfer rate and heat transfer augmentation efficiency. One tape was fully twisted and another tape was partially twisted. The shape of the SPT tape creates turbulence effect. The turbulence flow (swirl flow) generated by SPT tape promotes greater mixing and high heat transfer coefficients. An arrangement scheme has been developed for the experimental investigation. For remarking the rate of change of heat transfer, temperature has been measured numerically through the temperature sensors with various flow rates and RPM. The volume flow rate was varied from 10.3448276 LPM to 21.045574 LPM and the rotation of the perforated twisted tape was varied from 50 RPM to 400 RPM. Finally the research study demonstrates the effectiveness of the results of the proposed approaches. It is observed that the suggested method of heat transfer augmentations is much more effective than existing methods, since it results in an increase in heat transfer area and also an increase in the heat transfer coefficient and reduction of cost in the industrial sectors.

  7. The influence of a wall function on turbine blade heat transfer prediction

    NASA Technical Reports Server (NTRS)

    Whitaker, Kevin W.

    1989-01-01

    The second phase of a continuing investigation to improve the prediction of turbine blade heat transfer coefficients was completed. The present study specifically investigated how a numeric wall function in the turbulence model of a two-dimensional boundary layer code, STAN5, affected heat transfer prediction capabilities. Several sources of inaccuracy in the wall function were identified and then corrected or improved. Heat transfer coefficient predictions were then obtained using each one of the modifications to determine its effect. Results indicated that the modifications made to the wall function can significantly affect the prediction of heat transfer coefficients on turbine blades. The improvement in accuracy due the modifications is still inconclusive and is still being investigated.

  8. Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

    NASA Technical Reports Server (NTRS)

    Wang, C. R.; Towne, C. E.; Hippensteele, S. A.; Poinsatte, P. E.

    1997-01-01

    This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

  9. Hydrodynamics and Heat Transfer in the Case of Combined Flow in a Annular Channel of Small Cross Section

    NASA Astrophysics Data System (ADS)

    Komov, A. T.; Varava, A. N.; Dedov, A. V.; Zakharenkov, A. V.; Boltenko, É. A.

    2017-01-01

    The present work is a continuation of experimental investigations conducted at the Moscow Power Engineering Institute (MPEI) on heat-transfer intensification. Brief descriptions of the working section and structure of intensifiers are given and their basic geometric parameters are enumerated. New systematized experimental data on the coefficients of hydraulic resistance and heat transfer in the regime of single-phase convection are given in an extended range of regime parameters and geometric characteristics of the intensifiers. Considerable increase in the heat-transfer coefficient as a function of the geometric characteristics of the intensifier has been established experimentally. The values of the relative fin height, at which these are the maxima of heat transfer and hydraulic resistance, have been established. Calculated dependences for the coefficient of hydraulic resistance and heat transfer have been obtained.

  10. Influence of metal bonding layer on strain transfer performance of FBG

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Chen, Weimin; Zhang, Peng; Liu, Li; Shu, Yuejie; Wu, Jun

    2013-01-01

    Metal bonding layer seriously affects the strain transfer performance of Fiber Bragg Grating (FBG). Based on the mode of FBG strain transfer, the influence of the length, the thickness, Poisson's ratio, elasticity modulus of metal bonding layer on the strain transfer coefficient of FBG is analyzed by numerical simulation. FBG is packaged to steel wire using metal bonding technology of FBG. The tensile tests of different bonding lengths and elasticity modulus are carried out. The result shows the strain transfer coefficient of FBGs are 0.9848,0.962 and their average strain sensitivities are 1.076 pm/μɛ,1.099 pm/μɛ when the metal bonding layer is zinc, whose lengths are 15mm, 20mm, respectively. The strain transfer coefficient of FBG packaged by metal bonding layer raises 8.9 percent compared to epoxy glue package. The preliminary experimental results show that the strain transfer coefficient increases with the length of metal bonding layer, decreases with the thickness of metal bonding layer and the influence of Poisson's ratio can be ignored. The experiment result is general agreement with the analysis and provides guidance for metal package of FBG.

  11. Concentration Dependence of Pool Nucleate Boiling Heat Transfer Coefficients for R134a and Polyolester Oil System

    NASA Astrophysics Data System (ADS)

    Sato, Tomoaki; Takaishi, Yoshinori; Oguchi, Kosei

    This paper presents experimental results of the concentration dependence of heat transfer coefficients for mixtures of R134a and polyolester (POE) oil under the conditions of pool nuc1eateboiling. The experiments are conducted by means of ah horizontal platinum wire at saturation tel11peraturesof 9, 19, and 29°C and at oil concentrations from 0 to 8 mass%. The present results show that the boiling heat transfer coefficient for the system concerned decreases with increasing oil concentration as a whole but increases slightly at a low oil concentration of about 4 mass%. A correlation equation is also given as a function of heat flux, temperature and oil concentration to reproduce the experimental boiling heat transfer coefficient within an uncertainly of about±15%.

  12. Investigation of an inverted meniscus heat pipe wick concept

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.

    1975-01-01

    A wicking concept is described for efficient evaporation of heat pipe working fluids under diverse conditions. It embodies the high heat transfer coefficient of the circumferential groove while retaining the circumferential fluid transport capability of a thick porous wick or screen. Experimental tests are described which substantiate the efficacy of the evaporation technique for a circumferentially-grooved heat pipe charged alternately with ammonia and R-ll (CCl3F). With ammonia, heat transfer coefficients in the range of 2 to 2.7 W/sq cm K were measured at heat flux densities up to 20 W/sq cm while, with R-ll, a heat transfer coefficient of l.0 W/sq cm K was measured with flux densities up to 5 W/sq cm. Heat transfer coefficients and flux densities were unusually high compared to literature data for other nonboiling evaporative surfaces.

  13. Reduction of benzene and naphthalene mass transfer from crude oils by aging-induced interfacial films.

    PubMed

    Ghoshal, Subhasis; Pasion, Catherine; Alshafie, Mohammed

    2004-04-01

    Semi-rigid films or skins form at the interface of crude oil and water as a result of the accumulation of asphaltene and resin fractions when the water-immiscible crude oil is contacted with water for a period of time or "aged". The time varying patterns of area-independent mass transfer coefficients of two compounds, benzene and naphthalene, for dissolution from crude oil and gasoline were determined. Aqueous concentrations of the compounds were measured in the eluent from flow-through reactors, where a nondispersed oil phase and constant oil-water interfacial area were maintained. For Brent Blend crude oil and for gasoline amended with asphaltenes and resins, a rapid decrease in both benzene and naphthalene mass transfer coefficients over the first few days of aging was observed. The mass transfer coefficients of the two target solutes were reduced by up to 80% over 35 d although the equilibrium partition coefficients were unchanged. Aging of gasoline, which has negligible amounts of asphaltene and resin, did not result in a change in the solute mass transfer coefficients. The study demonstrates that formation of crude oil-water interfacial films comprised of asphaltenes and resins contribute to time-dependent decreases in rates of release of environmentally relevant solutes from crude oils and may contribute to the persistence of such solutes at crude oil-contaminated sites. It is estimated that the interfacial film has an extremely low film mass transfer coefficient in the range of 10(-6) cm/min.

  14. Experimental determination of surface heat transfer coefficient in a dry ice-ethanol cooling bath using a numerical approach.

    PubMed

    Santos, M V; Sansinena, M; Zaritzky, N; Chirife, J

    BACKGROUND: Dry ice-ethanol bath (-78 degree C) have been widely used in low temperature biological research to attain rapid cooling of samples below freezing temperature. The prediction of cooling rates of biological samples immersed in dry ice-ethanol bath is of practical interest in cryopreservation. The cooling rate can be obtained using mathematical models representing the heat conduction equation in transient state. Additionally, at the solid cryogenic-fluid interface, the knowledge of the surface heat transfer coefficient (h) is necessary for the convective boundary condition in order to correctly establish the mathematical problem. The study was to apply numerical modeling to obtain the surface heat transfer coefficient of a dry ice-ethanol bath. A numerical finite element solution of heat conduction equation was used to obtain surface heat transfer coefficients from measured temperatures at the center of polytetrafluoroethylene and polymethylmetacrylate cylinders immersed in a dry ice-ethanol cooling bath. The numerical model considered the temperature dependence of thermophysical properties of plastic materials used. A negative linear relationship is observed between cylinder diameter and heat transfer coefficient in the liquid bath, the calculated h values were 308, 135 and 62.5 W/(m 2 K) for PMMA 1.3, PTFE 2.59 and 3.14 cm in diameter, respectively. The calculated heat transfer coefficients were consistent among several replicates; h in dry ice-ethanol showed an inverse relationship with cylinder diameter.

  15. Impact of improved momentum transfer coefficients on the dynamics and thermodynamics of the north Indian Ocean

    NASA Astrophysics Data System (ADS)

    Parekh, Anant; Gnanaseelan, C.; Jayakumar, A.

    2011-01-01

    Long time series of in situ observations from the north Indian Ocean are used to compute the momentum transfer coefficients over the north Indian Ocean. The transfer coefficients behave nonlinearly for low winds (<4 m/s), when most of the known empirical relations assume linear relations. Impact of momentum transfer coefficients on the upper ocean parameters is studied using an ocean general circulation model. The model experiments revealed that the Arabian Sea and Equatorial Indian Ocean are more sensitive to the momentum transfer coefficients than the Bay of Bengal and south Indian Ocean. The impact of momentum transfer coefficients on sea surface temperature is up to 0.3°C-0.4°C, on mixed layer depth is up to 10 m, and on thermocline depth is up to 15 m. Furthermore, the impact on the zonal current is maximum over the equatorial Indian Ocean (i.e., about 0.12 m/s in May and 0.15 m/s in October; both May and October are the period of Wyrtki jets and the difference in current has potential impact on the seasonal mass transport). The Sverdrup transport has maximum impact in the Bay of Bengal (3 to 4 Sv in August), whereas the Ekman transport has maximum impact in the Arabian Sea (4 Sv during May to July). These highlight the potential impact of accurate momentum forcing on the results from current ocean models.

  16. Temperature Coefficient for Modeling Denitrification in Surface Water Sediments Using the Mass Transfer Coefficient

    Treesearch

    T. W. Appelboom; G. M. Chescheir; R. W. Skaggs; J. W. Gilliam; Devendra M. Amatya

    2006-01-01

    Watershed modeling has become an important tool for researchers with the high costs of water quality monitoring. When modeling nitrate transport within drainage networks, denitrification within the sediments needs to be accounted for. Birgand et. al. developed an equation using a term called a mass transfer coefficient to mathematically describe sediment...

  17. Temperature coefficient for modeling denitrification in surface water sediments using the mass transfer coefficient

    Treesearch

    T.W. Appelboom; G.M. Chescheir; F. Birgand; R.W. Skaggs; J.W. Gilliam; D. Amatya

    2010-01-01

    Watershed modeling has become an important tool for researchers. Modeling nitrate transport within drainage networks requires quantifying the denitrification within the sediments in canals and streams. In a previous study, several of the authors developed an equation using a term called a mass transfer coefficient to mathematically describe sediment denitrification....

  18. Temperature coefficient for modeling denitrification in surface water sediments using the mass transfer coefficient.

    Treesearch

    T.W. Appelboom; G.M. Chescheir; F. Birgand; R.W. Skaggs; J.W. Gilliam; D. Amatya

    2010-01-01

    Watershed modeling has become an important tool for researchers. Modeling nitrate transport within drainage networks requires quantifying the denitrification within the sediments in canals and streams. In a previous study, several of the authors developed an equation using a term called a mass transfer coefficient to mathematically describe sediment denitrification....

  19. Heat Transfer Measurements on Surfaces with Natural Ice Castings and Modeled Roughness

    NASA Technical Reports Server (NTRS)

    Breuer, Kenneth S.; Torres, Benjamin E.; Orr, D. J.; Hansman, R. John

    1997-01-01

    An experimental method is described to measure and compare the convective heat transfer coefficient of natural and simulated ice accretion roughness and to provide a rational means for determining accretion-related enhanced heat transfer coefficients. The natural ice accretion roughness was a sample casting made from accretions at the NASA Lewis Icing Research Tunnel (IRT). One of these castings was modeled using a Spectral Estimation Technique (SET) to produce three roughness elements patterns that simulate the actual accretion. All four samples were tested in a flat-plate boundary layer at angle of attack in a "dry" wind tunnel test. The convective heat transfer coefficient was measured using infrared thermography. It is shown that, dispite some problems in the current data set, the method does show considerable promise in determining roughness-induced heat transfer coefficients, and that, in addition to the roughness height and spacing in the flow direction, the concentration and spacing of elements in the spanwise direction are important parameters.

  20. Local heat-transfer measurements on a large, scale-model turbine blade airfoil using a composite of a heater element and liquid crystals

    NASA Technical Reports Server (NTRS)

    Hippensteele, S. A.; Russell, L. M.; Torres, F. J.

    1985-01-01

    Local heat transfer coefficients were experimentally mapped along the midchord of a five-time-size turbine blade airfoil in a static cascade operated at room temperature over a range of Reynolds numbers. The test surface consisted of a composite of commercially available materials: a mylar sheet with a layer of cholesteric liquid crystals, that change color with temperature, and a heater sheet made of a carbon-impregnated paper, that produces uniform heat flux. After the initial selection and calibration of the composite sheet, accurate, quantitative, and continuous heat transfer coefficients were mapped over the airfoil surface. The local heat transfer coefficients are presented for Reynolds numbers from 2.8 x 10 to the 5th power to 7.6 x 10 to the 5th power. Comparisons are made with analytical values of heat transfer coefficients obtained from the STAN5 boundary layer code. Also, a leading edge separation bubble was revealed by thermal and flow visualization.

  1. Heat transfer to horizontal tubes in a pilot-scale fluidized-bed combustor burning low-rank coals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grewal, N.S.; Goblirsch, G.

    Experimental data are obtained for the heat transfer coefficient between immersed horizontal tube bundles and an atmospheric-fluidized-bed combustor burning low-rank coals. Silica sand (d/sub p/ = 888 to 1484 ..mu..m) and limestone (d/sub p/ = 716 to 1895 ..mu..m) are used as bed material. The tests are conducted, with and without limestone addition and ash recycle, at average bed temperatures ranging from 1047 to 1125/sup 0/K, superficial fluidizing velocity of 1.66 to 2.04 m/s, and excess air levels of 15 to 40 percent. The experimental data are examined in the light of the existing correlations for the heat transfer coefficient.more » The predicted values of heat transfer coefficient from the correlations proposed by Grewal (1981) and Bansal et al. (1980) are found to be within +-25 percent of the experimental values of heat transfer coefficient, when the contribution due to radiation is also included. 5 figures, 5 tables.« less

  2. Integration Of Heat Transfer Coefficient In Glass Forming Modeling With Special Interface Element

    NASA Astrophysics Data System (ADS)

    Moreau, P.; César de Sá, J.; Grégoire, S.; Lochegnies, D.

    2007-05-01

    Numerical modeling of the glass forming processes requires the accurate knowledge of the heat exchange between the glass and the forming tools. A laboratory testing is developed to determine the evolution of the heat transfer coefficient in different glass/mould contact conditions (contact pressure, temperature, lubrication…). In this paper, trials are performed to determine heat transfer coefficient evolutions in experimental conditions close to the industrial blow-and-blow process conditions. In parallel of this work, a special interface element is implemented in a commercial Finite Element code in order to deal with heat transfer between glass and mould for non-meshing meshes and evolutive contact. This special interface element, implemented by using user subroutines, permits to introduce the previous heat transfer coefficient evolutions in the numerical modelings at the glass/mould interface in function of the local temperatures, contact pressures, contact time and kind of lubrication. The blow-and-blow forming simulation of a perfume bottle is finally performed to assess the special interface element performance.

  3. Evaluation of Computational Fluid Dynamics and Coupled Fluid-Solid Modeling for a Direct Transfer Preswirl System.

    PubMed

    Javiya, Umesh; Chew, John; Hills, Nick; Dullenkopf, Klaus; Scanlon, Timothy

    2013-05-01

    The prediction of the preswirl cooling air delivery and disk metal temperature are important for the cooling system performance and the rotor disk thermal stresses and life assessment. In this paper, standalone 3D steady and unsteady computation fluid dynamics (CFD), and coupled FE-CFD calculations are presented for prediction of these temperatures. CFD results are compared with previous measurements from a direct transfer preswirl test rig. The predicted cooling air temperatures agree well with the measurement, but the nozzle discharge coefficients are under predicted. Results from the coupled FE-CFD analyses are compared directly with thermocouple temperature measurements and with heat transfer coefficients on the rotor disk previously obtained from a rotor disk heat conduction solution. Considering the modeling limitations, the coupled approach predicted the solid metal temperatures well. Heat transfer coefficients on the rotor disk from CFD show some effect of the temperature variations on the heat transfer coefficients. Reasonable agreement is obtained with values deduced from the previous heat conduction solution.

  4. Radiative heat transfer and nonequilibrium Casimir-Lifshitz force in many-body systems with planar geometry

    NASA Astrophysics Data System (ADS)

    Latella, Ivan; Ben-Abdallah, Philippe; Biehs, Svend-Age; Antezza, Mauro; Messina, Riccardo

    2017-05-01

    A general theory of photon-mediated energy and momentum transfer in N -body planar systems out of thermal equilibrium is introduced. It is based on the combination of the scattering theory and the fluctuational-electrodynamics approach in many-body systems. By making a Landauer-like formulation of the heat transfer problem, explicit formulas for the energy transmission coefficients between two distinct slabs as well as the self-coupling coefficients are derived and expressed in terms of the reflection and transmission coefficients of the single bodies. We also show how to calculate local equilibrium temperatures in such systems. An analogous formulation is introduced to quantify momentum transfer coefficients describing Casimir-Lifshitz forces out of thermal equilibrium. Forces at thermal equilibrium are readily obtained as a particular case. As an illustration of this general theoretical framework, we show on three-body systems how the presence of a fourth slab can impact equilibrium temperatures in heat-transfer problems and equilibrium positions resulting from the forces acting on the system.

  5. Space-dependent perfusion coefficient estimation in a 2D bioheat transfer problem

    NASA Astrophysics Data System (ADS)

    Bazán, Fermín S. V.; Bedin, Luciano; Borges, Leonardo S.

    2017-05-01

    In this work, a method for estimating the space-dependent perfusion coefficient parameter in a 2D bioheat transfer model is presented. In the method, the bioheat transfer model is transformed into a time-dependent semidiscrete system of ordinary differential equations involving perfusion coefficient values as parameters, and the estimation problem is solved through a nonlinear least squares technique. In particular, the bioheat problem is solved by the method of lines based on a highly accurate pseudospectral approach, and perfusion coefficient values are estimated by the regularized Gauss-Newton method coupled with a proper regularization parameter. The performance of the method on several test problems is illustrated numerically.

  6. Determination of lateral-stability derivatives and transfer-function coefficients from frequency-response data for lateral motions

    NASA Technical Reports Server (NTRS)

    Donegan, James J; Robinson, Samuel W , Jr; Gates, Ordway, B , jr

    1955-01-01

    A method is presented for determining the lateral-stability derivatives, transfer-function coefficients, and the modes for lateral motion from frequency-response data for a rigid aircraft. The method is based on the application of the vector technique to the equations of lateral motion, so that the three equations of lateral motion can be separated into six equations. The method of least squares is then applied to the data for each of these equations to yield the coefficients of the equations of lateral motion from which the lateral-stability derivatives and lateral transfer-function coefficients are computed. Two numerical examples are given to demonstrate the use of the method.

  7. Persons with Haemophilia in Sweden- Experiences and Strategies in Everyday Life. A Single Centre Study

    PubMed Central

    2015-01-01

    Introduction/Aim Haemophilia is caused by deficiency in coagulation factor VIII or IX. Treatment with the missing coagulation factors has been available in most developed countries for several decades. The aim was to explore the experiences of adults living with severe or moderate haemophilia and their coping strategies at a single centre in Sweden. Method The interview study had a qualitative empirical approach and was analyzed on the basis of the method empirical phenomenological psychology. The sample included 14 participants, mean age 42 (19–80 y), who met the inclusion criteria and to saturation of information. Results: General characteristics were; All were satisfied with and grateful for access to medication. An acceptance of the disorder and willingness to live a normal life was identified among all participants. They were all content with the care provided by Haemophilia Treatment Centre (HTC) and felt supported by its multidisciplinary team. Four typologies were identified; Protective adults and assertive children during up-bringing, finding a role in social context, symptoms and treatments, fear of limited resources in the future. Task-, emotional- and avoidance coping strategies were seen in the interviews. The most prominent coping strategy was task oriented. Conclusion This interview study with Swedish PWH shows that they strive for normality and adaptation in social activities throughout life finding their own niche. The PWH expressed the importance of knowledge and support from the comprehensive medical team at HTC and therefore it seems important to continue comprehensive medical care at HTC in order to follow-up the haemophilia persons regularly. PMID:26431432

  8. The Open Science Grid - Support for Multi-Disciplinary Team Science - the Adolescent Years

    NASA Astrophysics Data System (ADS)

    Bauerdick, Lothar; Ernst, Michael; Fraser, Dan; Livny, Miron; Pordes, Ruth; Sehgal, Chander; Würthwein, Frank; Open Science Grid

    2012-12-01

    As it enters adolescence the Open Science Grid (OSG) is bringing a maturing fabric of Distributed High Throughput Computing (DHTC) services that supports an expanding HEP community to an increasingly diverse spectrum of domain scientists. Working closely with researchers on campuses throughout the US and in collaboration with national cyberinfrastructure initiatives, we transform their computing environment through new concepts, advanced tools and deep experience. We discuss examples of these including: the pilot-job overlay concepts and technologies now in use throughout OSG and delivering 1.4 Million CPU hours/day; the role of campus infrastructures- built out from concepts of sharing across multiple local faculty clusters (made good use of already by many of the HEP Tier-2 sites in the US); the work towards the use of clouds and access to high throughput parallel (multi-core and GPU) compute resources; and the progress we are making towards meeting the data management and access needs of non-HEP communities with general tools derived from the experience of the parochial tools in HEP (integration of Globus Online, prototyping with IRODS, investigations into Wide Area Lustre). We will also review our activities and experiences as HTC Service Provider to the recently awarded NSF XD XSEDE project, the evolution of the US NSF TeraGrid project, and how we are extending the reach of HTC through this activity to the increasingly broad national cyberinfrastructure. We believe that a coordinated view of the HPC and HTC resources in the US will further expand their impact on scientific discovery.

  9. Hard-to-cook bean (Phaseolus vulgaris L.) proteins hydrolyzed by alcalase and bromelain produced bioactive peptide fractions that inhibit targets of type-2 diabetes and oxidative stress.

    PubMed

    Oseguera-Toledo, Miguel E; Gonzalez de Mejia, Elvira; Amaya-Llano, Silvia L

    2015-10-01

    The objective was to evaluate the effect of bioactive peptide fractions from de-hulled hard-to-cook (HTC) bean on enzyme targets of type-2 diabetes and oxidative stress. Protein isolates from Pinto Durango and Negro 8025 beans were hydrolyzed (120min) with either alcalase® or bromelain and separated into five peptide fractions (<1, 1-3.5, 3.5-5, 5-10, and >10kDa) using an ultrafiltration membrane system. The <1kDa pinto Durango-bromelain fraction showed the best inhibition of α-amylase (49.9±1.4%), and the <1kDa pinto Durango-alcalase fraction inhibited both, α-glucosidase (76.4±0.5%), and dipeptidyl peptidase-IV (DPP-IV, 55.3±1.6%). Peptides LLSL, QQEG and NEGEAH were present in the most potent fractions. Hydrolysates and peptide fractions showed antioxidant capacity (ORAC: 159.6±2.9 to 932.6±1.1mmolTE/g) and nitric oxide inhibition (57.5±0.9 to 68.3±4.2%). Hydrolysates and fractions <1 and 1-3kDa were able to increase glucose-stimulated insulin secretion from iNS-1E cells up to 57% compared to glucose control. Hydrolysates from HTC beans inhibited enzymes related to diabetes management, being the smallest peptides (<1kDa) the most potent. HTC bean could be a source of protein to produce bioactive peptides with potential antidiabetic properties. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Comparative evaluation of methods for the determination of heat transfer coefficients of liquid and gaseous quenching media

    NASA Astrophysics Data System (ADS)

    Shevchenko, Svetlana Yu.; Melnik, Yury A.; Smirnov, Andrey E.; Htet, Wai Yan Min

    2018-03-01

    Temperature dependences of heat transfer coefficients of liquid and gaseous quenching media were determined using a gradient probe and prismatic probe of more simple design. The probes of two different designs were tested in the same conditions. Analysis of heat transfer coefficients showed good agreement between the data obtained. The tests were carried out with liquid and gaseous quenching media: water, polymer quenchant, quenching oil and high-pressure nitrogen. Methods of mathematical modeling of steel samples quenching show the adequacy of the results.

  11. Thermal Aspects of Using Alternative Nuclear Fuels in Supercritical Water-Cooled Reactors

    NASA Astrophysics Data System (ADS)

    Grande, Lisa Christine

    A SuperCritical Water-cooled Nuclear Reactor (SCWR) is a Generation IV concept currently being developed worldwide. Unique to this reactor type is the use of light-water coolant above its critical point. The current research presents a thermal-hydraulic analysis of a single fuel channel within a Pressure Tube (PT)-type SCWR with a single-reheat cycle. Since this reactor is in its early design phase many fuel-channel components are being investigated in various combinations. Analysis inputs are: steam cycle, Axial Heat Flux Profile (AHFP), fuel-bundle geometry, and thermophysical properties of reactor coolant, fuel sheath and fuel. Uniform and non-uniform AHFPs for average channel power were applied to a variety of alternative fuels (mixed oxide, thorium dioxide, uranium dicarbide, uranium nitride and uranium carbide) enclosed in an Inconel-600 43-element bundle. The results depict bulk-fluid, outer-sheath and fuel-centreline temperature profiles together with the Heat Transfer Coefficient (HTC) profiles along the heated length of fuel channel. The objective is to identify the best options in terms of fuel, sheath material and AHFPS in which the outer-sheath and fuel-centreline temperatures will be below the accepted temperature limits of 850°C and 1850°C respectively. The 43-element Inconel-600 fuel bundle is suitable for SCWR use as the sheath-temperature design limit of 850°C was maintained for all analyzed cases at average channel power. Thoria, UC2, UN and UC fuels for all AHFPs are acceptable since the maximum fuel-centreline temperature does not exceed the industry accepted limit of 1850°C. Conversely, the fuel-centreline temperature limit was exceeded for MOX at all AHFPs, and UO2 for both cosine and downstream-skewed cosine AHFPs. Therefore, fuel-bundle modifications are required for UO2 and MOX to be feasible nuclear fuels for SCWRs.

  12. Periodic Heat Transfer at Small Pressure Fluctuations

    NASA Technical Reports Server (NTRS)

    Pfriem, H.

    1943-01-01

    The effect of cyclic gas pressure variations on the periodic heat transfer at a flat wall is theoretically analyzed and the differential equation describing the process and its solution for relatively. Small pressure fluctuations developed, thus explaining the periodic heat cycle between gas and wall surface. The processes for pure harmonic pressure and temperature oscillations, respectively, in the gas space are described by means of a constant heat transfer coefficient and the equally constant phase angle between the appearance of the maximum values of the pressure and heat flow most conveniently expressed mathematically in the form of a complex heat transfer coefficient. Any cyclic pressure oscillations, can be reduced by Fourier analysis to harmonic oscillations, which result in specific, mutual relationships of heat-transfer coefficients and phase angles for the different harmonics.

  13. Consider a non-spherical elephant: computational fluid dynamics simulations of heat transfer coefficients and drag verified using wind tunnel experiments.

    PubMed

    Dudley, Peter N; Bonazza, Riccardo; Porter, Warren P

    2013-07-01

    Animal momentum and heat transfer analysis has historically used direct animal measurements or approximations to calculate drag and heat transfer coefficients. Research can now use modern 3D rendering and computational fluid dynamics software to simulate animal-fluid interactions. Key questions are the level of agreement between simulations and experiments and how superior they are to classical approximations. In this paper we compared experimental and simulated heat transfer and drag calculations on a scale model solid aluminum African elephant casting. We found good agreement between experimental and simulated data and large differences from classical approximations. We used the simulation results to calculate coefficients for heat transfer and drag of the elephant geometry. Copyright © 2013 Wiley Periodicals, Inc.

  14. Enhancement of convective heat transfer coefficient of ethylene glycol base cuprous oxide (Cu2O) nanofluids

    NASA Astrophysics Data System (ADS)

    Hassan, Ali; Ramzan, Naveed; Umer, Asim; Ahmad, Ayyaz; Muryam, Hina

    2018-02-01

    The enhancement in the convective heat transfer coefficient of the ethylene glycol (EG) base cuprous oxide (Cu2O) nanofluids were investigated. The nanofluids of different volume concentrations i-e 1%, 2.5% and 4.5% were prepared by the two step method. Cuprous oxide (Cu2O) nanoparticles were ultrasonically stirred for four hours in the ethylene glycol (EG). The experimental study has been performed through circular tube geometry in laminar flow regime at average Reynolds numbers 36, 71 and 116. The constant heat flux Q = 4000 (W/m2) was maintained during this work. Substantial enhancement was observed in the convective heat transfer coefficient of ethylene glycol (EG) base cuprous oxide (Cu2O) nanofluids than the base fluid. The maximum 74% enhancement was observed in convective heat transfer coefficient at 4.5 vol% concentration and Re = 116.

  15. Improving microalgal growth with small bubbles in a raceway pond with swing gas aerators.

    PubMed

    Yang, Zongbo; Cheng, Jun; Liu, Jianzhong; Zhou, Junhu; Cen, Kefa

    2016-09-01

    A novel swing gas aerator was developed to generate small bubbles for improving the mass transfer coefficient and microalgal growth rate in a raceway pond. A high-speed photography system (HSP) was used to measure the bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure the mass transfer coefficient and mixing time. Bubble generation time and diameter decreased by 21% and 9%, respectively, when rubber gas aerators were swung in the microalgae solution. When water pump power and gas aeration rate increased in a raceway pond with swing gas aerators and oscillating baffles (SGAOB), bubble generation time and diameter decreased but solution velocity and mass transfer coefficient increased. The mass transfer coefficient increased by 25% and the solution velocity increased by 11% when SGAOB was used, and the microalgal biomass yield increased by 18%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. A numerical model for boiling heat transfer coefficient of zeotropic mixtures

    NASA Astrophysics Data System (ADS)

    Barraza Vicencio, Rodrigo; Caviedes Aedo, Eduardo

    2017-12-01

    Zeotropic mixtures never have the same liquid and vapor composition in the liquid-vapor equilibrium. Also, the bubble and the dew point are separated; this gap is called glide temperature (Tglide). Those characteristics have made these mixtures suitable for cryogenics Joule-Thomson (JT) refrigeration cycles. Zeotropic mixtures as working fluid in JT cycles improve their performance in an order of magnitude. Optimization of JT cycles have earned substantial importance for cryogenics applications (e.g, gas liquefaction, cryosurgery probes, cooling of infrared sensors, cryopreservation, and biomedical samples). Heat exchangers design on those cycles is a critical point; consequently, heat transfer coefficient and pressure drop of two-phase zeotropic mixtures are relevant. In this work, it will be applied a methodology in order to calculate the local convective heat transfer coefficients based on the law of the wall approach for turbulent flows. The flow and heat transfer characteristics of zeotropic mixtures in a heated horizontal tube are investigated numerically. The temperature profile and heat transfer coefficient for zeotropic mixtures of different bulk compositions are analysed. The numerical model has been developed and locally applied in a fully developed, constant temperature wall, and two-phase annular flow in a duct. Numerical results have been obtained using this model taking into account continuity, momentum, and energy equations. Local heat transfer coefficient results are compared with available experimental data published by Barraza et al. (2016), and they have shown good agreement.

  17. Horizontal convective boiling of R448A, R449A, and R452B within a micro-fin tube

    PubMed Central

    KEDZIERSKI, MARK A.; KANG, DONGGYU

    2017-01-01

    This article presents local convective boiling measurements in a micro-fin tube for three low global warming potential refrigerants: R448A, R449A, and R452B1. An existing correlation was modified to predict multi-component mixtures, which predicted 98% of the measurements to within ±20%. The new correlation was used to compare the heat transfer coefficient of the three test fluids at the same heat flux, saturated refrigerant temperature, and refrigerant mass flux. The resulting comparison showed that refrigerant R452B exhibited the highest heat transfer, in large part due to its approximately 28% larger liquid thermal conductivity and smaller temperature glide as compared to the tested low-global warming potential refrigerants. For the example case, the heat transfer coefficient for R449A was approximately 8% larger than that for R448A, while the heat transfer coefficient for R452B was more than 59% larger than either R448A or R449A. The heat transfer coefficients for R448A and R449A were roughly between 26 and 48% less than that of R404A for the example case. In contrast, the model predicts that the R452B heat transfer coefficient was approximately 13% larger than that of R404A for the same conditions. PMID:28758148

  18. Effect of aperture geometry on heat transfer in tilted partially open cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsayed, M.M.; Chakroun, W.

    1999-11-01

    Heat transfer in cavities is receiving increasing attention because of the various applications in engineering; e.g., passive solar heating, energy conservation in buildings, solar concentrating receivers, and electronic equipment. Here, convection from a square, tilted partially open cavity was investigated experimentally. The experiment was carried out to study the effect of the aperture geometry on the heat transfer between the cavity and the surrounding air. Four different geometrical arrangements for the opening were investigated: (1) high wall slit, (2) low wall slit, (3) centered wall slit, and (4) uniform wall slots. Each opening arrangement was studied at opening ratios (i.e.,more » ratio of opening height to cavity height) of 0.25, 0.5, and 0.75. The average heat transfer coefficient between the cavity and the surrounding air was estimated for each geometrical arrangement for tilt angles ranging from {minus}90 deg to +90 deg with increments of 15 deg and at a constant heat flux Grashof number of 5.5 x 10{sup 8}. The results showed that for tilt angles between 90 and 75 deg, the heat transfer coefficient has a small value that is independent of the geometrical arrangement of the opening. The value of the heat transfer coefficient increases sharply with decreasing tilt angle until an angle value of zero degrees is reached. The increase in the heat transfer coefficient continues in the negative range of tilt angle but not in the same rate as in the positive range of the tilt angle. The uniform slot arrangement gave in general higher heat transfer coefficient than the other three arrangements of the opening. Large differences in the heat transfer coefficient were observed between the high and the low wall slits where the high wall slit is found to transfer more heat to the surroundings than the low wall slit. Correlations were developed to predict the average Nusselt number of the cavity in terms of the opening ratio and the cavity tilt angle for cavities with high wall slit, low wall slit, centered wall slit, and the uniform wall slots.« less

  19. Heat transfer coefficients for staggered arrays of short pin fins

    NASA Technical Reports Server (NTRS)

    Vanfossen, G. J.

    1981-01-01

    Short pin fins are often used to increase that heat transfer to the coolant in the trailing edge of a turbine blade. Due primarily to limits of casting technology, it is not possible to manufacture pins of optimum length for heat transfer purposes in the trailing edge region. In many cases the pins are so short that they actually decrease the total heat transfer surface area compared to a plain wall. A heat transfer data base for these short pins is not available in the literature. Heat transfer coefficients on pin and endwall surfaces were measured for several staggered arrays of short pin fins. The measured Nusselt numbers when plotted versus Reynolds numbers were found to fall on a single curve for all surfaces tested. The heat transfer coefficients for the short pin fins (length to diameter ratios of 1/2 and 2) were found to be about a factor of two lower than data from the literature for longer pin arrays (length to diameter ratios of about 8).

  20. Numerical investigation of saturated upward flow boiling of water in a vertical tube using VOF model: effect of different boundary conditions

    NASA Astrophysics Data System (ADS)

    Hasanpour, B.; Irandoost, M. S.; Hassani, M.; Kouhikamali, R.

    2018-01-01

    In this paper a numerical simulation of upward two-phase flow evaporation in a vertical tube has been studied by considering water as working fluid. To this end, the computational fluid dynamic simulations of this system are performed with heat and mass transfer mechanisms due to energy transfer during the phase change interaction near the heat transfer surface. The volume of fluid model in an available Eulerian-Eulerian approach based on finite volume method is utilized and the mass source term in conservation of mass equation is implemented using a user defined function. The characteristics of water flow boiling such as void fraction and heat transfer coefficient distribution are investigated. The main cause of fluctuations on heat transfer coefficient and volume fraction is velocity increment in the vapor phase rather than the liquid phase. The case study of this research including convective heat transfer coefficient and tube diameter are considered as a parametric study. The operating conditions are considered at high pressure in saturation temperature and the physical properties of water are determined by considering system's inlet temperature and pressure in saturation conditions. Good agreement is achieved between the numerical and the experimental values of heat transfer coefficients.

  1. Numerical investigation of saturated upward flow boiling of water in a vertical tube using VOF model: effect of different boundary conditions

    NASA Astrophysics Data System (ADS)

    Hasanpour, B.; Irandoost, M. S.; Hassani, M.; Kouhikamali, R.

    2018-07-01

    In this paper a numerical simulation of upward two-phase flow evaporation in a vertical tube has been studied by considering water as working fluid. To this end, the computational fluid dynamic simulations of this system are performed with heat and mass transfer mechanisms due to energy transfer during the phase change interaction near the heat transfer surface. The volume of fluid model in an available Eulerian-Eulerian approach based on finite volume method is utilized and the mass source term in conservation of mass equation is implemented using a user defined function. The characteristics of water flow boiling such as void fraction and heat transfer coefficient distribution are investigated. The main cause of fluctuations on heat transfer coefficient and volume fraction is velocity increment in the vapor phase rather than the liquid phase. The case study of this research including convective heat transfer coefficient and tube diameter are considered as a parametric study. The operating conditions are considered at high pressure in saturation temperature and the physical properties of water are determined by considering system's inlet temperature and pressure in saturation conditions. Good agreement is achieved between the numerical and the experimental values of heat transfer coefficients.

  2. Experimental study on convective heat transfer of TiO2 nanofluids

    NASA Astrophysics Data System (ADS)

    Vakili, M.; Mohebbi, A.; Hashemipour, H.

    2013-08-01

    In this study, nanofluids with different TiO2 nanoparticle concentrations were synthesized and measured in different constant heat fluxes for their heat transfer behavior upon flowing through a vertical pipe. Addition of nanoparticles into the base fluid enhances the forced convective heat transfer coefficient. The results show that the enhancement of the convective heat transfer coefficient in the mixture consisting of ethylene glycol and distilled water is more than distilled water as a base fluid.

  3. Forced convective heat transfer in curved diffusers

    NASA Technical Reports Server (NTRS)

    Rojas, J.; Whitelaw, J. H.; Yianneskis, M.

    1987-01-01

    Measurements of the velocity characteristics of the flows in two curved diffusers of rectangular cross section with C and S-shaped centerlines are presented and related to measurements of wall heat transfer coefficients along the heated flat walls of the ducts. The velocity results were obtained by laser-Doppler anemometry in a water tunnel and the heat transfer results by liquid crystal thermography in a wind tunnel. The thermographic technique allowed the rapid and inexpensive measurement of wall heat transfer coefficients along flat walls of arbitrary boundary shapes with an accuracy of about 5 percent. The results show that an increase in secondary flow velocities near the heated wall causes an increase in the local wall heat transfer coefficient, and quantify the variation for maximum secondary-flow velocities in a range from 1.5 to 17 percent of the bulk flow velocity.

  4. Use of a liquid-crystal, heater-element composite for quantitative, high-resolution heat transfer coefficients on a turbine airfoil, including turbulence and surface roughness effects

    NASA Astrophysics Data System (ADS)

    Hippensteele, Steven A.; Russell, Louis M.; Torres, Felix J.

    1987-05-01

    Local heat transfer coefficients were measured along the midchord of a three-times-size turbine vane airfoil in a static cascade operated at roon temperature over a range of Reynolds numbers. The test surface consisted of a composite of commercially available materials: a Mylar sheet with a layer of cholestric liquid crystals, which change color with temperature, and a heater made of a polyester sheet coated with vapor-deposited gold, which produces uniform heat flux. After the initial selection and calibration of the composite sheet, accurate, quantitative, and continuous heat transfer coefficients were mapped over the airfoil surface. Tests were conducted at two free-stream turbulence intensities: 0.6 percent, which is typical of wind tunnels; and 10 percent, which is typical of real engine conditions. In addition to a smooth airfoil, the effects of local leading-edge sand roughness were also examined for a value greater than the critical roughness. The local heat transfer coefficients are presented for both free-stream turbulence intensities for inlet Reynolds numbers from 1.20 to 5.55 x 10 to the 5th power. Comparisons are also made with analytical values of heat transfer coefficients obtained from the STAN5 boundary layer code.

  5. Use of a liquid-crystal and heater-element composite for quantitative, high-resolution heat-transfer coefficients on a turbine airfoil including turbulence and surface-roughness effects

    NASA Astrophysics Data System (ADS)

    Hippensteele, S. A.; Russell, L. M.; Torres, F. J.

    Local heat transfer coefficients were measured along the midchord of a three-times-size turbine vane airfoil in a static cascade operated at room temperature over a range of Reynolds numbers. The test surface consisted of a composite of commercially available materials: a Mylar sheet with a layer of cholestric liquid crystals, which change color with temperature, and a heater made of a polyester sheet coated with vapor-deposited gold, which produces uniform heat flux. After the initial selection and calibration of the composite sheet, accurate, quantitative, and continuous heat transfer coefficients were mapped over the airfoil surface. Tests were conducted at two free-stream turbulence intensities: 0.6 percent, which is typical of wind tunnels; and 10 percent, which is typical of real engine conditions. In addition to a smooth airfoil, the effects of local leading-edge sand roughness were also examined for a value greater than the critical roughness. The local heat transfer coefficients are presented for both free-stream turbulence intensities for inlet Reynolds numbers from 1.20 to 5.55 x 10 to the 5th power. Comparisons are also made with analytical values of heat transfer coefficients obtained from the STAN5 boundary layer code.

  6. Use of a liquid-crystal, heater-element composite for quantitative, high-resolution heat transfer coefficients on a turbine airfoil, including turbulence and surface roughness effects

    NASA Technical Reports Server (NTRS)

    Hippensteele, Steven A.; Russell, Louis M.; Torres, Felix J.

    1987-01-01

    Local heat transfer coefficients were measured along the midchord of a three-times-size turbine vane airfoil in a static cascade operated at roon temperature over a range of Reynolds numbers. The test surface consisted of a composite of commercially available materials: a Mylar sheet with a layer of cholestric liquid crystals, which change color with temperature, and a heater made of a polyester sheet coated with vapor-deposited gold, which produces uniform heat flux. After the initial selection and calibration of the composite sheet, accurate, quantitative, and continuous heat transfer coefficients were mapped over the airfoil surface. Tests were conducted at two free-stream turbulence intensities: 0.6 percent, which is typical of wind tunnels; and 10 percent, which is typical of real engine conditions. In addition to a smooth airfoil, the effects of local leading-edge sand roughness were also examined for a value greater than the critical roughness. The local heat transfer coefficients are presented for both free-stream turbulence intensities for inlet Reynolds numbers from 1.20 to 5.55 x 10 to the 5th power. Comparisons are also made with analytical values of heat transfer coefficients obtained from the STAN5 boundary layer code.

  7. The ultrasonic-enhanced factor of mass-transfer coefficient in the supercritical carbon dioxide extraction

    NASA Astrophysics Data System (ADS)

    Luo, Benyi; Lu, Yigang

    2008-10-01

    Based on several hypotheses about the process of supercritical carbon dioxide extraction, the onflow around the solute granule is figured out by the Navier-Stocks equation. In combination with the Higbie’s solute infiltration model, the link between the mass-transfer coefficient and the velocity of flow is found. The mass-transfer coefficient with the ultrasonical effect is compared with that without the ultrasonical effect, and then a new parameter named the ultrasonic-enhanced factor of mass-transfer coefficient is brought forward, which describes the mathematical model of the supercritical carbon dioxide extraction process enhanced by ultrasonic. The model gives out the relationships among the ultrasonical power, the ultrasonical frequency, the radius of solute granule and the ultrasonic-enhanced factor of mass-transfer coefficient. The results calculated by this model fit well with the experimental data, including the extraction of Coix Lacryma-jobi Seed Oil (CLSO) and Coix Lacryma-jobi Seed Ester (CLSE) from coix seeds and the extraction of Eicosapentaenoic Acid (EPA) and Docosahexaenoic Acid (DHA) from the alga by means of the ultrasonic-enhanced supercritical carbon dioxide extraction (USFE) and the supercritical carbon dioxide extraction (SFE) respectively. This proves the rationality of the ultrasonic-enhanced factor model. The model provides a theoretical basis for the application of ultrasonic-enhanced supercritical fluid extraction technique.

  8. Energy transfer and energy absorption in photon interactions with matter revisited: A step-by-step illustrated approach

    NASA Astrophysics Data System (ADS)

    Abdel-Rahman, W.; Podgorsak, E. B.

    2010-05-01

    A clear understanding of energy transfer and energy absorption in photon interactions with matter is essential for the understanding of radiation dosimetry and development of new dosimetry techniques. The concepts behind the two quantities have been enunciated many years ago and described in many scientific papers, review articles, and textbooks. Data dealing with energy transfer and energy absorption as well as the associated mass energy transfer coefficient and the mass energy absorption coefficient are readily available in web-based tabular forms. However, tables, even when available in detailed and easy to access form, do not lend themselves to serve as visual aid to promote better understanding of the dosimetric quantities related to energy transfer and energy absorption as well as their relationship to the photon energy and absorber atomic number. This paper uses graphs and illustrations, in addition to well-known mathematical relationships, to guide the reader in a systematic manner through the various stages involved in the derivation of energy absorbed in medium and its associated quantity, the mass energy absorption coefficient, from the mass attenuation coefficient.

  9. Modelling mass transfer during venting/soil vapour extraction: Non-aqueous phase liquid/gas mass transfer coefficient estimation

    NASA Astrophysics Data System (ADS)

    Esrael, D.; Kacem, M.; Benadda, B.

    2017-07-01

    We investigate how the simulation of the venting/soil vapour extraction (SVE) process is affected by the mass transfer coefficient, using a model comprising five partial differential equations describing gas flow and mass conservation of phases and including an expression accounting for soil saturation conditions. In doing so, we test five previously reported quations for estimating the non-aqueous phase liquid (NAPL)/gas initial mass transfer coefficient and evaluate an expression that uses a reference NAPL saturation. Four venting/SVE experiments utilizing a sand column are performed with dry and non-saturated sand at low and high flow rates, and the obtained experimental results are subsequently simulated, revealing that hydrodynamic dispersion cannot be neglected in the estimation of the mass transfer coefficient, particularly in the case of low velocities. Among the tested models, only the analytical solution of a convection-dispersion equation and the equation proposed herein are suitable for correctly modelling the experimental results, with the developed model representing the best choice for correctly simulating the experimental results and the tailing part of the extracted gas concentration curve.

  10. Integration Of Heat Transfer Coefficient In Glass Forming Modeling With Special Interface Element

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreau, P.; Gregoire, S.; Lochegnies, D.

    2007-05-17

    Numerical modeling of the glass forming processes requires the accurate knowledge of the heat exchange between the glass and the forming tools. A laboratory testing is developed to determine the evolution of the heat transfer coefficient in different glass/mould contact conditions (contact pressure, temperature, lubrication...). In this paper, trials are performed to determine heat transfer coefficient evolutions in experimental conditions close to the industrial blow-and-blow process conditions. In parallel of this work, a special interface element is implemented in a commercial Finite Element code in order to deal with heat transfer between glass and mould for non-meshing meshes and evolutivemore » contact. This special interface element, implemented by using user subroutines, permits to introduce the previous heat transfer coefficient evolutions in the numerical modelings at the glass/mould interface in function of the local temperatures, contact pressures, contact time and kind of lubrication. The blow-and-blow forming simulation of a perfume bottle is finally performed to assess the special interface element performance.« less

  11. Active latent heat storage with a screw heat exchanger - experimental results for heat transfer and concept for high pressure steam

    NASA Astrophysics Data System (ADS)

    Zipf, Verena; Willert, Daniel; Neuhäuser, Anton

    2016-05-01

    An innovative active latent heat storage concept was invented and developed at Fraunhofer ISE. It uses a screw heat exchanger (SHE) for the phase change during the transport of a phase change material (PCM) from a cold to a hot tank or vice versa. This separates heat transfer and storage tank in comparison to existing concepts. A test rig has been built in order to investigate the heat transfer coefficients of the SHE during melting and crystallization of the PCM. The knowledge of these characteristics is crucial in order to assess the performance of the latent heat storage in a thermal system. The test rig contains a double shafted SHE, which is heated or cooled with thermal oil. The overall heat transfer coefficient U and the convective heat transfer coefficient on the PCM side hPCM both for charging and discharging have been calculated based on the measured data. For charging, the overall heat transfer coefficient in the tested SHE was Uch = 308 W/m2K and for discharging Udis = 210 W/m2K. Based on the values for hPCM the overall heat transfer coefficients for a larger SHE with steam as heat transfer fluid and an optimized geometry were calculated with Uch = 320 W/m2K for charging and Udis = 243 W/m2K for discharging. For pressures as high as p = 100 bar, an SHE concept has been developed, which uses an organic fluid inside the flight of the SHE as working media. With this concept, the SHE can also be deployed for very high pressure, e.g. as storage in solar thermal power plants.

  12. Comparison of heat transfer coefficients of open micro-channels and plain micro-fins

    NASA Astrophysics Data System (ADS)

    Kaniowski, Robert; Pastuszko, Robert

    2018-06-01

    The paper describes results of analysis of pool boiling heat transfer on enhanced surfaces. Two types of structural surfaces were used: open microchannel surfaces consisting of a system of parallel micro-channels 0.3 mm wide, from 0.2 to 0.5 mm deep and with a pitch of 0.6 mm, and plain micro-fins 0.5 mm in height, uniformly spaced on the base surface with a spacing from 0.6 to1.5 mm. Pool boiling data at atmospheric pressure were obtained for saturated water, ethanol and FC-72. The effects of micro-channel/micro-fin dimensions on heat transfer coefficient in nucleate pool boiling were examined. Substantial enhancement of heat transfer coefficient was observed.

  13. Nucleate pool boiling heat transfer characteristics of TiO{sub 2}-water nanofluids at very low concentrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suriyawong, Adirek; Wongwises, Somchai

    2010-11-15

    A study of nucleate pool boiling heat transfer of TiO{sub 2}-water nanofluids is experimentally conducted. Nanofluids with various concentrations of 0.00005, 0.0001, 0.0005, 0.005, and 0.01 vol.% are employed. Horizontal circular plates made from copper and aluminium with different roughness values of 0.2 and 4 {mu}m are used as heating surfaces. The experiments are performed to explore the effects of nanofluids concentration as well as heating surface material and roughness on nucleate pool boiling characteristics and the heat transfer coefficient under ambient pressure. The results show that based on the copper heated surface which is tested with a concentration ofmore » 0.0001 vol.%, higher nucleate pool boiling heat transfer coefficient is obtained when compared with the base fluid. A 15% increase is obtained for the surface roughness of 0.2 {mu}m and a 4% increase is obtained for roughness of 4 {mu}m. For concentrations higher than 0.0001 vol.%, however, the higher the concentration, the lower the heat transfer coefficient. In the case of aluminium heated surface, the corresponding heat transfer coefficients are larger than for the copper surface by around 30% with a roughness of 0.2 {mu}m and around 27% with a roughness of 4 {mu}m. Moreover, the results also indicate that the heat transfer coefficient obtained based on a roughness of 4 {mu}m is higher than that for a roughness of 0.2 {mu}m by around 12% for aluminium and by around 13% for copper. (author)« less

  14. Hydrothermal Carbonization: a feasible solution to convert biomass to soil?

    NASA Astrophysics Data System (ADS)

    Tesch, Walter; Tesch, Petra; Pfeifer, Christoph

    2013-04-01

    The erosion of fertile soil is a severe problem arising right after peak oil (Myers 1996). That this issue is not only a problem of arid countries is shown by the fact that even the European Commission defined certain milestones to address the problem of soil erosion in Europe (European Commission 2011). The application of bio-char produced by torrefaction or pyrolysis for the remediation, revegetation and restoration of depleted soils started to gain momentum recently (Rillig 2010, Lehmann 2011, Beesley 2011). Hydrothermal carbonization (HTC) is a promising thermo-chemical process that can be applied to convert organic feedstock into fertile soil and water, two resources which are of high value in regions being vulnerable to erosion. The great advantage of HTC is that organic feedstock (e.g. organic waste) can be used without any special pretreatment (e.g. drying) and so far no restrictions have been found regarding the composition of the organic matter. By applying HTC the organic material is processed along a defined pathway in the Van Krevelen plot (Behrendt 2006). By stopping the process at an early stage a nutritious rich material can be obtained, which is known to be similar to terra preta. Considering that HTC-coal is rich in functional groups and can be derived from the process under "wet" conditions, it can be expected that it shall allow soil bacteria to settle more easily compared to the bio-char derived by torrefaction or pyrolysis. In addition, up to 10 tons process water per ton organic waste can be gained (Vorlop 2009). Thus, as organic waste, loss of fertile soil and water scarcity becomes a serious issue within the European Union, hydrothermal carbonization can provide a feasible solution to address these issues of our near future. The presentation reviews the different types of feedstock investigated for the HTC-Process so far and gives an overview on the current stage of development of this technology. References Beesley L., Moreno-Jiménez E., Gomez-Eyles J.L., Harris H., Robinson B., Sizmur T.: A review of biochars' potential role in the remediation, revegetation and restoration of contaminated soils. Environmental Pollution (159), p. 3269 - 3282, 2011. Behrendt F.: Direktverflüssigung von Biomasse - Reaktionsmechanismen und Produktverteilungen Institut für Energietechnik, Technische Universität Berlin Studie im Auftrag der Bundesanstalt für Landwirtschaft und Ernährung; Projektnummer 114-50-10-0337/05-B, 2006. European Commission: "Roadmap to a Resource Efficient Europe", COM(2011) 571. Lehmann J., Rillig M.C., Thies J., Masiello C.A., Hockaday W.C., Crowley D.: Biochar effects on soil biota - A review, Soil Biology & Biochemistry, p. 1-25, 2011. Myers Norman: "Environmental services of biodiversity", Proc. Natl. Acad. Sci. USA Vol 93, pp. 2764 - 2769, 1996. Rillig M.C., Wagner M., Salem M., Antunes P.M., George C., Ramke H.G., Titirici M.M., Antonietti M.: Material derived from hydrothermal carbonization: effects on plant growth and arbuscular mycorrhiza. Applied Soil Ecology (45), p. 238 - 242, 2010. Vorlop K.D., Schuchardt F., Prüße U.: Hydrothermale Carbonisierung Analyse und Ausblicke. FNR-Fachgespräch, Berlin, 2009.

  15. DCE-MRI-Derived Volume Transfer Constant (Ktrans) and DWI Apparent Diffusion Coefficient as Predictive Markers of Short- and Long-Term Efficacy of Chemoradiotherapy in Patients With Esophageal Cancer.

    PubMed

    Ye, Zhi-Min; Dai, Shu-Jun; Yan, Feng-Qin; Wang, Lei; Fang, Jun; Fu, Zhen-Fu; Wang, Yue-Zhen

    2018-01-01

    This study aimed to evaluate both the short- and long-term efficacies of chemoradiotherapy in relation to the treatment of esophageal cancer . This was achieved through the use of dynamic contrast-enhanced magnetic resonance imaging-derived volume transfer constant and diffusion weighted imaging-derived apparent diffusion coefficient . Patients with esophageal cancer were assigned into the sensitive and resistant groups based on respective efficacies in chemoradiotherapy. Dynamic contrast-enhanced magnetic resonance imaging and diffusion weighted imaging were used to measure volume transfer constant and apparent diffusion coefficient, while computed tomography was used to calculate tumor size reduction rate. Pearson correlation analyses were conducted to analyze correlation between volume transfer constant, apparent diffusion coefficient, and the tumor size reduction rate. Receiver operating characteristic curve was constructed to analyze the short-term efficacy of volume transfer constant and apparent diffusion coefficient, while Kaplan-Meier curve was employed for survival rate analysis. Cox proportional hazard model was used for the risk factors for prognosis of patients with esophageal cancer. Our results indicated reduced levels of volume transfer constant, while increased levels were observed in ADC min , ADC mean , and ADC max following chemoradiotherapy. A negative correlation was determined between ADC min , ADC mean , and ADC max , as well as in the tumor size reduction rate prior to chemoradiotherapy, whereas a positive correlation was uncovered postchemoradiotherapy. Volume transfer constant was positively correlated with tumor size reduction rate both before and after chemoradiotherapy. The 5-year survival rate of patients with esophageal cancer having high ADC min , ADC mean , and ADC max and volume transfer constant before chemoradiotherapy was greater than those with respectively lower values. According to the Cox proportional hazard model, ADC mean , clinical stage, degree of differentiation, and tumor stage were all confirmed as being independent risk factors in regard to the prognosis of patients with EC. The findings of this study provide evidence suggesting that volume transfer constant and apparent diffusion coefficient as being tools allowing for the evaluation of both the short- and long-term efficacies of chemoradiotherapy esophageal cancer treatment.

  16. Hydrothermal carbonization: modeling, final properties design and applications: a review

    USDA-ARS?s Scientific Manuscript database

    Active research on biomass hydrothermal carbonization (HTC) continues to demonstrate its advantages over other thermochemical processes, in particular the interesting benefits associated with carbonaceous solid products called hydrochar (HC). The areas of applications of HC range from biofuel to dop...

  17. Hydrothermal carbonization of livestock mortality for the reduction of pathogens and microbially-derived DNA

    USDA-ARS?s Scientific Manuscript database

    Hydrothermal carbonization (HTC), utilizing high temperature and pressure, has the potential to treat agricultural waste and inactivate pathogens, antibiotic resistance genes (ARG), and contaminants of emerging concern (CEC) in an environmentally and economically friendly manner. Livestock mortality...

  18. OVERALL MASS TRANSFER COEFFICIENT FOR POLLUTANT EMISSIONS FROM SMALL WATER POOLS UNDER SIMULATED INDOOR ENVIRONMENTAL CONDITIONS

    EPA Science Inventory

    Small chamber tests were conducted to experimentally determine the overall mass transfer coefficient for pollutant emissions from still water under simulated indoor-residential or occupational-environmental conditions. Fourteen tests were conducted in small environmental chambers...

  19. Determination of the apparent transfer coefficient for CO oxidation on Pt(poly), Pt(111), Pt(665) and Pt(332) using a potential modulation technique.

    PubMed

    Wang, Han-Chun; Ernst, Siegfried; Baltruschat, Helmut

    2010-03-07

    The apparent transfer coefficient, which gives the magnitude of the potential dependence of the electrochemical reaction rates, is the key quantity for the elucidation of electrochemical reaction mechanisms. We introduce the application of an ac method to determine the apparent transfer coefficient alpha' for the oxidation of pre-adsorbed CO at polycrystalline and single-crystalline Pt electrodes in sulfuric acid. The method allows to record alpha' quasi continuously as a function of potential (and time) in cyclic voltammetry or at a fixed potential, with the reaction rate varying with time. At all surfaces (Pt(poly), Pt(111), Pt(665), and Pt(332)) we clearly observed a transition of the apparent transfer coefficient from values around 1.5 at low potentials to values around 0.5 at higher potentials. Changes of the apparent transfer coefficients for the CO oxidation with potential were observed previously, but only from around 0.7 to values as low as 0.2. In contrast, our experimental findings completely agree with the simulation by Koper et al., J. Chem. Phys., 1998, 109, 6051-6062. They can be understood in the framework of a Langmuir-Hinshelwood mechanism. The transition occurs when the sum of the rate constants for the forward reaction (first step: potential dependent OH adsorption, second step: potential dependent oxidation of CO(ad) with OH(ad)) exceeds the rate constant for the back-reaction of the first step. We expect that the ac method for the determination of the apparent transfer coefficient, which we used here, will be of great help also in many other cases, especially under steady conditions, where the major limitations of the method are avoided.

  20. HIV prevention costs and their predictors: evidence from the ORPHEA Project in Kenya

    PubMed Central

    Galárraga, Omar; Wamai, Richard G; Sosa-Rubí, Sandra G; Mugo, Mercy G; Contreras-Loya, David; Bautista-Arredondo, Sergio; Nyakundi, Helen; Wang’ombe, Joseph K

    2017-01-01

    Abstract We estimate costs and their predictors for three HIV prevention interventions in Kenya: HIV testing and counselling (HTC), prevention of mother-to-child transmission (PMTCT) and voluntary medical male circumcision (VMMC). As part of the ‘Optimizing the Response of Prevention: HIV Efficiency in Africa’ (ORPHEA) project, we collected retrospective data from government and non-governmental health facilities for 2011–12. We used multi-stage sampling to determine a sample of health facilities by type, ownership, size and interventions offered totalling 144 sites in 78 health facilities in 33 districts across Kenya. Data sources included key informants, registers and time-motion observation methods. Total costs of production were computed using both quantity and unit price of each input. Average cost was estimated by dividing total cost per intervention by number of clients accessing the intervention. Multivariate regression methods were used to analyse predictors of log-transformed average costs. Average costs were $7 and $79 per HTC and PMTCT client tested, respectively; and $66 per VMMC procedure. Results show evidence of economies of scale for PMTCT and VMMC: increasing the number of clients per year by 100% was associated with cost reductions of 50% for PMTCT, and 45% for VMMC. Task shifting was associated with reduced costs for both PMTCT (59%) and VMMC (54%). Costs in hospitals were higher for PMTCT (56%) in comparison to non-hospitals. Facilities that performed testing based on risk factors as opposed to universal screening had higher HTC average costs (79%). Lower VMMC costs were associated with availability of male reproductive health services (59%) and presence of community advisory board (52%). Aside from increasing production scale, HIV prevention costs may be contained by using task shifting, non-hospital sites, service integration and community supervision. PMID:29029086

  1. Operational feasibility of using whole blood in the rapid HIV testing algorithm of a resource-limited settings like Bangladesh.

    PubMed

    Munshi, Saif U; Oyewale, Tajudeen O; Begum, Shahnaz; Uddin, Ziya; Tabassum, Shahina

    2016-03-01

    Serum-based rapid HIV testing algorithm in Bangladesh constitutes operational challenge to scaleup HIV testing and counselling (HTC) in the country. This study explored the operational feasibility of using whole blood as alternative to serum for rapid HIV testing in Bangladesh. Whole blood specimens were collected from two study groups. The groups included HIV-positive patients (n = 200) and HIV-negative individuals (n = 200) presenting at the reference laboratory in Dhaka, Bangladesh. The specimens were subjected to rapid HIV tests using the national algorithm with A1 = Alere Determine (United States), A2 = Uni-Gold (Ireland), and A3 = First Response (India). The sensitivity and specificity of the test results, and the operational cost were compared with current serum-based testing. The sensitivities [95% of confidence interval (CI)] for A1, A2, and A3 tests using whole blood were 100% (CI: 99.1-100%), 100% (CI: 99.1-100%), and 97% (CI: 96.4-98.2%), respectively, and specificities of all test kits were 100% (CI: 99.1-100%). Significant (P < 0.05) reduction in the cost of establishing HTC centre and consumables by 94 and 61%, respectively, were observed. The cost of administration and external quality assurance reduced by 39 and 43%, respectively. Overall, there was a 36% cost reduction in total operational cost of rapid HIV testing with blood when compared with serum. Considering the similar sensitivity and specificity of the two specimens, and significant cost reduction, rapid HIV testing with whole blood is feasible. A review of the national HIV rapid testing algorithm with whole blood will contribute toward improving HTC coverage in Bangladesh.

  2. Air/molten salt direct-contact heat-transfer experiment and economic analysis

    NASA Astrophysics Data System (ADS)

    Bohn, M. S.

    1983-11-01

    Direct-contact heat-transfer coefficients have been measured in a pilot-scale packed column heat exchanger for molten salt/air duty. Two types of commercial tower packings were tested: metal Raschig rings and initial Pall rings. Volumetric heat-transfer coefficients were measured and appeared to depend upon air flow but not on salt flow rate. An economic analysis was used to compare the cost-effectiveness of direct-contact heat exchange with finned-tube heat exchanger in this application. Incorporating the measured volumetric heat-transfer coefficients, a direct-contact system appeared to be from two to five times as cost-effective as a finned-tube heat exchanger, depending upon operating temperature. The large cost advantage occurs for higher operating temperatures (2700(0)C), where high rates of heat transfer and flexibility in materials choice give the cost advantage to the direct-contact heat exchanger.

  3. Mass transfer parameters of celeriac during vacuum drying

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2017-04-01

    An accurate prediction of moisture transfer parameters is very important for efficient mass transfer analysis, accurate modelling of drying process, and better designing of new dryers and optimization of existing drying process. The present study aimed to investigate the influence of temperature (e.g., 55, 65 and 75 °C) and chamber pressure (e.g., 0.1, 3, 7, 10, 13 and 17 kPa) on effective diffusivity and convective mass transfer coefficient of celeriac slices during vacuum drying. The obtained Biot number indicated that the moisture transfer in the celeriac slices was controlled by both internal and external resistance. The effective diffusivity obtained to be in the ranges of 7.5231 × 10-10-3.8015 × 10-9 m2 s-1. The results showed that the diffusivity increased with increasing temperature and decreasing pressure. The mass transfer coefficient values varied from 4.6789 × 10-7 to 1.0059 × 10-6 m s-1, and any increment in drying temperature and pressure caused an increment in the coefficient.

  4. Condensation heat transfer and pressure drop of R-410A in a 7.0 mm O.D. microfin tube at low mass fluxes

    NASA Astrophysics Data System (ADS)

    Kim, Nae-Hyun

    2016-12-01

    R-410A condensation heat transfer and pressure drop data are provided for a 7.0 mm O.D. microfin tube at low mass fluxes (50-250 kg/m2 s). The heat transfer coefficient of the microfin tube shows a minimum behavior with the mass flux. At a low mass flux, where flow pattern is stratified, condensation induced by surface tension by microfins overwhelms condensation induced by shear, and the heat transfer coefficient decreases as mass flux increases. At a high mass flux, where flow pattern is annular, condensation induced by shear governs the heat transfer, and the heat transfer coefficient increases as mass flux increases. The pressure drop of the microfin tube is larger than that of the smooth tube at the annular flow regime. On the contrary, the pressure drop of the smooth tube is larger than that of the microfin tube at the stratified flow regime.

  5. A study of the flow boiling heat transfer in a minichannel for a heated wall with surface texture produced by vibration-assisted laser machining

    NASA Astrophysics Data System (ADS)

    Piasecka, Magdalena; Strąk, Kinga; Maciejewska, Beata; Grabas, Bogusław

    2016-09-01

    The paper presents results concerning flow boiling heat transfer in a vertical minichannel with a depth of 1.7 mm and a width of 16 mm. The element responsible for heating FC-72, which flowed laminarly in the minichannel, was a plate with an enhanced surface. Two types of surface textures were considered. Both were produced by vibration-assisted laser machining. Infrared thermography was used to record changes in the temperature on the outer smooth side of the plate. Two-phase flow patterns were observed through a glass pane. The main aim of the study was to analyze how the two types of surface textures affect the heat transfer coefficient. A two-dimensional heat transfer approach was proposed to determine the local values of the heat transfer coefficient. The inverse problem for the heated wall was solved using a semi-analytical method based on the Trefftz functions. The results are presented as relationships between the heat transfer coefficient and the distance along the minichannel length and as boiling curves. The experimental data obtained for the two types of enhanced heated surfaces was compared with the results recorded for the smooth heated surface. The highest local values of the heat transfer coefficient were reported in the saturated boiling region for the plate with the type 1 texture produced by vibration-assisted laser machining.

  6. Heat transfer coefficient: Medivance Arctic Sun Temperature Management System vs. water immersion.

    PubMed

    English, M J; Hemmerling, T M

    2008-07-01

    To improve heat transfer, the Medivance Arctic Sun Temperature Management System (Medivance, Inc., Louisville, CO, USA) features an adhesive, water-conditioned, highly conductive hydrogel pad for intimate skin contact. This study measured and compared the heat transfer coefficient (h), i.e. heat transfer efficiency, of this pad (hPAD), in a heated model and in nine volunteers' thighs; and of 10 degrees C water (hWATER) in 33 head-out immersions by 11 volunteers. Volunteer studies had ethical approval and written informed consent. Calibrated heat flux transducers measured heat flux (W m-2). Temperature gradient (DeltaT) was measured between skin and pad or water temperatures. Temperature gradient was changed through the pad's water temperature controller or by skin cooling on immersion. The heat transfer coefficient is the slope of W m-2/DeltaT: its unit is W m-2 degrees C-1. Average with (95% CI) was: model, hPAD = 110.4 (107.8-113.1), R2 = 0.99, n = 45; volunteers, hPAD = 109.8 (95.5-124.1), R2 = 0.83, n = 51; and water immersion, hWATER = 107.1 (98.1-116), R2 = 0.86, n = 94. The heat transfer coefficient for the pad was the same in the model and volunteers, and equivalent to hWATER. Therefore, for the same DeltaT and heat transfer area, the Arctic Sun's heat transfer rate would equal water immersion. This has important implications for body cooling/rewarming rates.

  7. Corrosion and Heat Transfer Characteristics of Water Dispersed with Carboxylate Additives and Multi Walled Carbon Nano Tubes

    NASA Astrophysics Data System (ADS)

    Moorthy, Chellapilla V. K. N. S. N.; Srinivas, Vadapalli

    2016-10-01

    This paper summarizes a recent work on anti-corrosive properties and enhanced heat transfer properties of carboxylated water based nanofluids. Water mixed with sebacic acid as carboxylate additive found to be resistant to corrosion and suitable for automotive environment. The carboxylated water is dispersed with very low mass concentration of carbon nano tubes at 0.025, 0.05 and 0.1 %. The stability of nanofluids in terms of zeta potential is found to be good with carboxylated water compared to normal water. The heat transfer performance of nanofluids is carried out on an air cooled heat exchanger similar to an automotive radiator with incoming air velocities across radiator at 5, 10 and 15 m/s. The flow Reynolds number of water is in the range of 2500-6000 indicating developing flow regime. The corrosion resistance of nanofluids is found to be good indicating its suitability to automotive environment. There is a slight increase in viscosity and marginal decrease in the specific heat of nanofluids with addition of carboxylate as well as CNTs. Significant improvement is observed in the thermal conductivity of nanofluids dispersed with CNTs. During heat transfer experimentation, the inside heat transfer coefficient and overall heat transfer coefficient has also improved markedly. It is also found that the velocity of air and flow rate of coolant plays an important role in enhancement of the heat transfer coefficient and overall heat transfer coefficient.

  8. Experimental investigation of heat transfer of R134a in pool boiling on stainless steel and aluminum tubes

    NASA Astrophysics Data System (ADS)

    Wengler, C.; Addy, J.; Luke, A.

    2018-03-01

    Due to high energy demand required for chemical processes, refrigeration and process industries the increase of efficiency and performance of thermal systems especially evaporators is indispensable. One of the possibilities to meet this purpose are investigations in enhancement of the heat transfer in nucleate boiling where high heat fluxes at low superheat are transferred. In the present work, the heat transfer in pool boiling is investigated with pure R134a over wide ranges of reduced pressures and heat fluxes. The heating materials of the test tubes are aluminum and stainless steel. The influence of the thermal conductivity on the heat transfer coefficients is analysed by the surface roughness of sandblasted surfaces. The heat transfer coefficient increases with increasing thermal conductivity, surface roughness and reduced pressures. The experimental results show a small degradation of the heat transfer coefficients between the two heating materials aluminum and stainless steel. In correlation with the VDI Heat Atlas, the experimental results are matching well with the predictions but do not accurately consider the stainless steel material reference properties.

  9. Experimental and Numerical Investigation of Forced Convection Heat Transfer in Heat Sink with Rectangular Plates at Varying Inclinations on Vertical Base

    NASA Astrophysics Data System (ADS)

    Patil, Harshal Bhauso; Dingare, Sunil Vishnu

    2018-03-01

    Heat exchange upgrade is a vital territory of research area. Utilization of reasonable systems can bring about noteworthy specialized points of interest coming about reserve funds of cost. Rectangular plates are viewed as best balance arrangement utilized for heat exchange improvement. This gives an enlargement strategy to heat exchange with beginning of limit layer and vortex development. To assess and look at the rate of heat exchange enhancement by rectangular plate fins with differing inclinations (0°-30°-60°), shifting Re and heat supply under forced convection are the principle destinations of this study. The study is done by fluctuating introductions of fins with various inclinations, input heat supply and Re under forced convection. The coefficient of heat transfer increments observed with the expansion in air speed for all the examined designs. The coefficient of the heat transfer is discovered higher at the edge of introduction of fins at 30° for inline arrangement and 0° for staggered arrangement. Looking at both the arrangements, it is discovered that the heat transfer coefficient in 0° fin staggered arrangement is about 17% higher than 30° inline arrangement and 76% higher than the vertical plate fin. For plate fin heat sink, boundary layer formation and growth results in decrease of the coefficient of heat transfer in forced convection. This issue is overcome by accommodating some rectangular fins on the plate fin. It brings about increment of heat transfer coefficient of the RPFHS under the states of trial factors. As indicated by past research, it is discovered that examination of the plate fin heat sink with various sorts of fins for horizontal orientation is done yet but this investigation expects to discover the upgrade of transfer coefficient of plate fin heat sink for its vertical position with rectangular plates at different inclinations under the shifting scopes of heat input supply, fin arrangements and Reynolds number (Re).

  10. Forced and natural convection in aggregate-laden nanofluids

    NASA Astrophysics Data System (ADS)

    Thajudeen, Thaseem; Hogan, Christopher J.

    2011-12-01

    A number of experimental and theoretical studies of convective heat transfer in nanofluids (liquid suspensions of nanoparticles, typically with features below 100 nm in size) reveal contrasting results; nanoparticles can either enhance or reduce the convective heat transfer coefficient. These disparate conclusions regarding the influence of nanoparticles on convective heat transfer may arise due to the aggregation of nanoparticles, which is often not considered in studies of nanofluids. Here, we examine theoretically forced and natural convective heat transfer of aggregate-laden nanofluids using Monte Carlo-based models to determine how the aggregate morphology influences the convective heat transfer coefficient. Specifically, in this study, it is first shown that standard heat transfer correlations should apply to nanofluids, and the main influence of the nanoparticles is to alter suspension thermal conductivity, dynamic viscosity, density, specific heat, and thermal expansion coefficient. Aggregated particles in suspension are modeled as quasi-fractal aggregates composed of individual primary particles described by the primary particle radius, number of primary particles, fractal (Hausdorff) dimension, pre-exponential factor, and degree of coalescence between primary particles. A sequential algorithm is used to computationally generate aggregates with prescribed morphological descriptors. Four types of aggregates are considered; spanning the range of aggregate morphologies observed in nanofluids. For each morphological type, the influences of aggregates on nanofluid dynamic viscosity and thermal conductivity are determined via first passage-based Brownian dynamics calculations. It is found that depending on both the material properties of the nanoparticles as well as the nanoparticle morphology, the addition of nanoparticles to a suspension can either increase or decrease both the forced and natural convective heat transfer coefficients, with both a 51% increase and a 32% decrease in the heat transfer coefficient achievable at particle volume fractions of 0.05. This study shows clearly that the influence of particle morphology needs to be accounted for in all studies of heat transfer in nanofluids.

  11. Designing high efficiency organic photovoltaics by controlling the ordering at the donor-acceptor interface

    NASA Astrophysics Data System (ADS)

    Mohite, Aditya; Nie, Wanyi; Gupta, Gautam; Crone, Brian; Kuo, Chenyu; Tsai, Hsinhan; Smith, Darryl; Ruden, Paul; Liu, Feilong; Wang, Hsing-Lin; Tretiak, Sergei

    2014-03-01

    The overall power conversion efficiency in an organic solar cell depends on the balance between the rates of exciton dissociation, recombination and separation at the donor acceptor interface. Inability to design, control and engineer these interfaces remains a key bottleneck in their widespread use for the next generation organic electronic devices. Here, we show that we can control the ordering at the P3HT/C60 interface in bilayer device geometry by inserting a monolayer of oligothiophenes, which leads to a complete suppression in the exciplex (or charge transfer state) recombination. We observe that the photocurrent increases by 500%, which in turn results in an increase in the overall power conversion efficiency by an order of magnitude. Moreover, we find that the oligothiophene with an odd number of rings (ter and penta oligothiophene) exhibit a much higher increase in the photocurrent in comparison to the oligothiophene with an even number of rings (tetra oligothiphene). STM measurements reveal that the oligothiophene with odd and even number of rings differ in their ordering respectively, that has a big effect on the overall device performance. We also find that this ordering is highly dependent on the side functional groups in the oligothiophenes. The mechanism of photocurrent generation will be discussed and a simple transport model will be used to explain the change in the charge transfer and recombination rates and predict current-voltage curves.

  12. The influence of chemical composition of LNG on the supercritical heat transfer in an intermediate fluid vaporizer

    NASA Astrophysics Data System (ADS)

    Xu, Shuangqing; Chen, Xuedong; Fan, Zhichao; Chen, Yongdong; Nie, Defu; Wu, Qiaoguo

    2018-04-01

    A three-dimensional transient computational fluid dynamics (CFD) model has been established for the simulations of supercritical heat transfer of real liquefied natural gas (LNG) mixture in a single tube and a tube bundle of an intermediate fluid vaporizer (IFV). The influence of chemical composition of LNG on the thermal performance has been analyzed. The results have also been compared with those obtained from the one-dimensional steady-state calculations using the distributed parameter model (DPM). It is found that the current DPM approach can give reasonable prediction accuracy for the thermal performance in the tube bundle but unsatisfactory prediction accuracy for that in a single tube as compared with the corresponding CFD data. As benchmarked against pure methane, the vaporization of an LNG containing about 90% (mole fraction) of methane would lead to an absolute deviation of 5.5 K in the outlet NG temperature and a maximum relative deviation of 11.4% in the tube side HTC in a bundle of about 816 U tubes at the inlet pressure of 12 MPa and mass flux of 200 kg·m-2·s-1. It is concluded that the influence of LNG composition on the thermal performance should be taken into consideration in order to obtain an economic and reliable design of an IFV.

  13. Effects of cooling system parameters on heat transfer in PAFC stack. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Abdul-Aziz, Ali A.

    1985-01-01

    Analytical and experimental study for the effects of cooling system parameters on the heat transfer and temperature distribution in the electrode plates of a phosphoric acid fuel-cell has been conducted. An experimental set-up that simulates the operating conditions prevailing in a phosphoric-acid fuel-cell stack was designed and constructed. The set-up was then used to measure the overall heat transfer coefficient, the thermal contact resistance, and the electrode temperature distribution for two different cooling plate configurations. Two types of cooling plate configurations, serpentine and straight, were tested. Air, water, and oil were used as coolants. Measurements for the heat transfer coefficient and the thermal contact resistance were made for various flow rates ranging from 16 to 88 Kg/hr, and stack clamping pressure ranging from O to 3448 Kpa. The experimental results for the overall heat transfer coefficient were utilized to derive mathematical relations for the overall heat transfer coefficient as a function of stack clamping pressure and Reynolds number for the three coolants. The empirically derived formulas were incorporated in a previously developed computer program to predict electrodes temperature distribution and the performance of the stack cooling system. The results obtained were then compared with those available in the literature. The comparison showed maximum deviation of +/- 11%.

  14. Experimental Study on Cooling Heat Transfer of Supercritical Carbon Dioxide Inside Horizontal Micro-Fin Tubes

    NASA Astrophysics Data System (ADS)

    Kuwahara, Ken; Higashiiu, Shinya; Ito, Daisuke; Koyama, Shigeru

    This paper deals with the experimental study on cooling heat transfer of supercritical carbon dioxide inside micro-fin tubes. The geometrical parameters in micro-fin tubes used in the present study are 6.02 mm in outer diameter, 4.76 mm to 5.11 mm in average inner diameter, 0.15 mm to 0.24 mm in fin height, 5 to 25 in helix angle, 46 to 52 in number of fins and 1.4 to 2.3 in area expansion ratio. Heat transfer coefficients were measured at 8-10 MPa in pressure, 360-690 kg/(m2•s) in mass velocity and 20-75 °C in CO2 temperature. The measured heat transfer coefficients of micro-fin tubes were 1.4 to 2 times higher than those of the smooth tube having 4.42 in inner diameter. The predicted heat transfer coefficients using the correlation equation, which was developed for single-phase turbulent fluid flow inside micro-fin-tubes, showed large deviations to the measured values. The new correlation to predict cooling heat transfer coefficient of supercritical carbon dioxide inside micro-fin tubes was developed taking into account the shape of fins based on experimental data empirically. This correlation equation agreed within ±20% of almost all of the experimental data.

  15. Environmental applications of HTC technology: Biochar production, carbon sequestration, and waste conversion

    USDA-ARS?s Scientific Manuscript database

    Motivations for the development and use of hydrothermal carbonization (or wet pyrolysis) have been primarily directed towards the sustainable creation of carbon nanomaterials/nanostructures for use in applications ranging from hydrogen storage to chemical adsorption. The utility of this process, how...

  16. Properties of animal-manure based hydrochars and predictions using published models

    USDA-ARS?s Scientific Manuscript database

    In order to fully utilize hydrothermal carbonization (HTC) to produce value-added hydrochars from animal manures, it is important to understand how process conditions (e.g., temperature, reaction time, solids concentration) influence product characteristics. The effect of process conditions on the e...

  17. Prediction of mass transfer coefficients in non-Newtonian fermentation media using first-principles methods.

    PubMed

    Radl, Stefan; Khinast, Johannes G

    2007-08-01

    Bubble flows in non-Newtonian fluids were analyzed using first-principles methods with the aim to compute and predict mass transfer coefficients in such fermentation media. The method we used is a Direct Numerical Simulation (DNS) of the reactive multiphase flow with deformable boundaries and interfaces. With this method, we are able for the first time to calculate mass transfer coefficients in non-Newtonian liquids of different rheologies without any experimental data. In the current article, shear-thinning fluids are considered. However, the results provide the basis for further investigations, such as the study of viscoelastic fluids. (c) 2007 Wiley Periodicals, Inc.

  18. A new statistical method for transfer coefficient calculations in the framework of the general multiple-compartment model of transport for radionuclides in biological systems.

    PubMed

    Garcia, F; Arruda-Neto, J D; Manso, M V; Helene, O M; Vanin, V R; Rodriguez, O; Mesa, J; Likhachev, V P; Filho, J W; Deppman, A; Perez, G; Guzman, F; de Camargo, S P

    1999-10-01

    A new and simple statistical procedure (STATFLUX) for the calculation of transfer coefficients of radionuclide transport to animals and plants is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. By using experimentally available curves of radionuclide concentrations versus time, for each animal compartment (organs), flow parameters were estimated by employing a least-squares procedure, whose consistency is tested. Some numerical results are presented in order to compare the STATFLUX transfer coefficients with those from other works and experimental data.

  19. Quantifying the sensitivity of feedstock properties and process conditions on hydrochar yield, carbon content, and energy content.

    PubMed

    Li, Liang; Wang, Yiying; Xu, Jiting; Flora, Joseph R V; Hoque, Shamia; Berge, Nicole D

    2018-08-01

    Hydrothermal carbonization (HTC) is a wet, low temperature thermal conversion process that continues to gain attention for the generation of hydrochar. The importance of specific process conditions and feedstock properties on hydrochar characteristics is not well understood. To evaluate this, linear and non-linear models were developed to describe hydrochar characteristics based on data collected from HTC-related literature. A Sobol analysis was subsequently conducted to identify parameters that most influence hydrochar characteristics. Results from this analysis indicate that for each investigated hydrochar property, the model fit and predictive capability associated with the random forest models is superior to both the linear and regression tree models. Based on results from the Sobol analysis, the feedstock properties and process conditions most influential on hydrochar yield, carbon content, and energy content were identified. In addition, a variational process parameter sensitivity analysis was conducted to determine how feedstock property importance changes with process conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Analysis of electric current flow through the HTc multilayered superconductors

    NASA Astrophysics Data System (ADS)

    Sosnowski, J.

    2016-02-01

    Issue of the flow of the transport current through multilayered high-temperature superconductors is considered, depending on the direction of the electric current towards the surface of the superconducting CuO2 layers. For configuration of the current flow inside of the layers and for perpendicular magnetic field, it will be considered the current limitations connected with interaction of pancake type vortices with nano-sized defects, created among other during fast neutrons irradiation. So it makes this issue associated with work of nuclear energy devices, like tokamak ITER, LHC and actually developed accelerator Nuclotron-NICA, as well as cryocables. Phenomenological analysis of the pinning potential barrier formation will be in the paper given, which determines critical current flow inside the plane. Comparison of theoretical model with experimental data will be presented too as well as influence of fast neutrons irradiation dose on critical current calculated. For current direction perpendicular to superconducting planes the current-voltage characteristics are calculated basing on model assuming formation of long intrinsic Josephson's junctions in layered HTc superconductors.

  1. An Improved Method of Pose Estimation for Lighthouse Base Station Extension.

    PubMed

    Yang, Yi; Weng, Dongdong; Li, Dong; Xun, Hang

    2017-10-22

    In 2015, HTC and Valve launched a virtual reality headset empowered with Lighthouse, the cutting-edge space positioning technology. Although Lighthouse is superior in terms of accuracy, latency and refresh rate, its algorithms do not support base station expansion, and is flawed concerning occlusion in moving targets, that is, it is unable to calculate their poses with a small set of sensors, resulting in the loss of optical tracking data. In view of these problems, this paper proposes an improved pose estimation algorithm for cases where occlusion is involved. Our algorithm calculates the pose of a given object with a unified dataset comprising of inputs from sensors recognized by all base stations, as long as three or more sensors detect a signal in total, no matter from which base station. To verify our algorithm, HTC official base stations and autonomous developed receivers are used for prototyping. The experiment result shows that our pose calculation algorithm can achieve precise positioning when a few sensors detect the signal.

  2. An Improved Method of Pose Estimation for Lighthouse Base Station Extension

    PubMed Central

    Yang, Yi; Weng, Dongdong; Li, Dong; Xun, Hang

    2017-01-01

    In 2015, HTC and Valve launched a virtual reality headset empowered with Lighthouse, the cutting-edge space positioning technology. Although Lighthouse is superior in terms of accuracy, latency and refresh rate, its algorithms do not support base station expansion, and is flawed concerning occlusion in moving targets, that is, it is unable to calculate their poses with a small set of sensors, resulting in the loss of optical tracking data. In view of these problems, this paper proposes an improved pose estimation algorithm for cases where occlusion is involved. Our algorithm calculates the pose of a given object with a unified dataset comprising of inputs from sensors recognized by all base stations, as long as three or more sensors detect a signal in total, no matter from which base station. To verify our algorithm, HTC official base stations and autonomous developed receivers are used for prototyping. The experiment result shows that our pose calculation algorithm can achieve precise positioning when a few sensors detect the signal. PMID:29065509

  3. Co-hydrothermal treatment of fallen leaves with iron sludge to prepare magnetic iron product and solid fuel.

    PubMed

    Gu, Lin; Li, Binglian; Wen, Haifeng; Zhang, Xin; Wang, Liang; Ye, Jianfeng

    2018-06-01

    The hydrothermal carbonization (HTC) was performed on Metasequoia Leaves (ML) in the presence of iron sludge, both of which were generated as solid residuals. The relations between sludge, char's properties and operating conditions were systemically investigated. Iron sludge primarily catalyzed the efficient formation of char with higher heating value (HHV) becoming 1.15-1.65 times of ML (18.21 MJ/kg) and was meanwhile reduced to magnetite. The hydrated Fe ions in octahedron crystals acted as nucleophiles facilitating the dehydration and decarboxylation reactions. The increased HHV is found strong temperature dependent while prolonging the residence time is more preferable for low organic acids generation. Thermogravimetric analysis confirmed the iron sludge enhanced conversion of volatile to fixed carbon. The as-prepared solid char showed better stability after catalytic HTC treatment, having ignition temperature increased from 253 to 426 °C as compared to the char prepared without iron sludge addition. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Effect of hydrothermal carbonization on storage process of woody pellets: Pellets' properties and aldehydes/ketones emission.

    PubMed

    Li, Hui; Wang, Siyuan; Huang, Zhongliang; Yuan, Xingzhong; Wang, Ziliang; He, Rao; Xi, Yanni; Zhang, Xuan; Tan, Mengjiao; Huang, Jing; Mo, Dan; Li, Changzhu

    2018-07-01

    Effect of hydrothermal carbonization (HTC) on the hydrochar pelletization and the aldehydes/ketones emission from pellets during storage was investigated. Pellets made from the hydrochar were stored in sealed apparatuses for sampling. The energy consumption during pelletization and the pellets' properties before/after storage, including dimension, density, moisture content, hardness, aldehyde/ketones emission amount/rate and unsaturated fatty acid amount, were analyzed. Compared with untreated-sawdust-pellets, the hydrochar-pellets required more energy consumption for pelletization, and achieved the improved qualities, resulting in the higher stability degree during storage. The species and amount of unsaturated fatty acids in the hydrochar-pellets were higher than those in the untreated-sawdust-pellets. The unsaturated fatty acids content in the hydrochar-pellets was decreased with increasing HTC temperature. Higher aldehydes/ketones emission amount and rates with a longer emission period were found for the hydrochar-pellets, associated with variations of structure and unsaturated fatty acid composition in pellets. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Determination of the external mass transfer coefficient and influence of mixing intensity in moving bed biofilm reactors for wastewater treatment.

    PubMed

    Nogueira, Bruno L; Pérez, Julio; van Loosdrecht, Mark C M; Secchi, Argimiro R; Dezotti, Márcia; Biscaia, Evaristo C

    2015-09-01

    In moving bed biofilm reactors (MBBR), the removal of pollutants from wastewater is due to the substrate consumption by bacteria attached on suspended carriers. As a biofilm process, the substrates are transported from the bulk phase to the biofilm passing through a mass transfer resistance layer. This study proposes a methodology to determine the external mass transfer coefficient and identify the influence of the mixing intensity on the conversion process in-situ in MBBR systems. The method allows the determination of the external mass transfer coefficient in the reactor, which is a major advantage when compared to the previous methods that require mimicking hydrodynamics of the reactor in a flow chamber or in a separate vessel. The proposed methodology was evaluated in an aerobic lab-scale system operating with COD removal and nitrification. The impact of the mixing intensity on the conversion rates for ammonium and COD was tested individually. When comparing the effect of mixing intensity on the removal rates of COD and ammonium, a higher apparent external mass transfer resistance was found for ammonium. For the used aeration intensities, the external mass transfer coefficient for ammonium oxidation was ranging from 0.68 to 13.50 m d(-1) and for COD removal 2.9 to 22.4 m d(-1). The lower coefficient range for ammonium oxidation is likely related to the location of nitrifiers deeper in the biofilm. The measurement of external mass transfer rates in MBBR will help in better design and evaluation of MBBR system-based technologies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A novel inverse numerical modeling method for the estimation of water and salt mass transfer coefficients during ultrasonic assisted-osmotic dehydration of cucumber cubes.

    PubMed

    Kiani, Hosein; Karimi, Farzaneh; Labbafi, Mohsen; Fathi, Morteza

    2018-06-01

    The objective of this paper was to study the moisture and salt diffusivity during ultrasonic assisted-osmotic dehydration of cucumbers. Experimental measurements of moisture and salt concentration versus time were carried out and an inverse numerical method was performed by coupling a CFD package (OpenFOAM) with a parameter estimation software (DAKOTA) to determine mass transfer coefficients. A good agreement between experimental and numerical results was observed. Mass transfer coefficients were from 3.5 × 10 -9 to 7 × 10 -9  m/s for water and from 4.8 × 10 -9  m/s to 7.4 × 10 -9  m/s for salt at different conditions (diffusion coefficients of around 3.5 × 10 -12 -11.5 × 10 -12  m 2 /s for water and 5 × 10 -12  m/s-12 × 10 -12  m 2 /s for salt). Ultrasound irradiation could increase the mass transfer coefficient. The values obtained by this method were closer to the actual data. The inverse simulation method can be an accurate technique to study the mass transfer phenomena during food processing. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Combined experimental-numerical identification of radiative transfer coefficients in white LED phosphor layers

    NASA Astrophysics Data System (ADS)

    Akolkar, A.; Petrasch, J.; Finck, S.; Rahmatian, N.

    2018-02-01

    An inverse analysis of the phosphor layer of a commercially available, conformally coated, white LED is done based on tomographic and spectrometric measurements. The aim is to determine the radiative transfer coefficients of the phosphor layer from the measurements of the finished device, with minimal assumptions regarding the composition of the phosphor layer. These results can be used for subsequent opto-thermal modelling and optimization of the device. For this purpose, multiple integrating sphere and gonioradiometric measurements are done to obtain statistical bounds on spectral radiometric values and angular color distributions for ten LEDs belonging to the same color bin of the product series. Tomographic measurements of the LED package are used to generate a tetrahedral grid of the 3D LED geometry. A radiative transfer model using Monte Carlo Ray Tracing in the tetrahedral grid is developed. Using a two-wavelength model consisting of a blue emission wavelength and a yellow, Stokes-shifted re-emission wavelength, the angular color distribution of the LED is simulated over wide ranges of the absorption and scattering coefficients of the phosphor layer, for the blue and yellow wavelengths. Using a two-step, iterative space search, combinations of the radiative transfer coefficients are obtained for which the simulations are consistent with the integrating sphere and gonioradiometric measurements. The results show an inverse relationship between the scattering and absorption coefficients of the phosphor layer for blue light. Scattering of yellow light acts as a distribution and loss mechanism for yellow light and affects the shape of the angular color distribution significantly, especially at larger viewing angles. The spread of feasible coefficients indicates that measured optical behavior of the LEDs may be reproduced using a range of combinations of radiative coefficients. Given that coefficients predicted by the Mie theory usually must be corrected in order to reproduce experimental results, these results indicate that a more complete model of radiative transfer in phosphor layers is required.

  8. Hydrodynamics, mass transfer, and yeast culture performance of a column bioreactor with ejector.

    PubMed

    Prokop, A; Janík, P; Sobotka, M; Krumphanzl, V

    1983-04-01

    A bubble column fitted with an ejector has been tested for its physical and biological performance. The axial diffusion coefficient of the liquid phase in the presence of electrolytes and ethanol was measured by a stimulus-response technique with subsequent evaluation by means of a diffusion model. In contrast to ordinary bubble columns, the coefficient of axial mixing is inversely dependent on the superficial air velocity. The liquid velocity acts in an opposite direction to the backmixing flow in the column. The measurement of volumetric oxygen transfer coefficient in the presence of electrolytes and ethanol was performed using a dynamic gassing-in method adapted for a column. The data were correlated with the superficial air and liquid velocities, total power input, and power for aeration and mixing; the economy coefficient of oxygen transfer was used for finding an optimum ratio of power for aeration and pumping. Growth experiments with Candida utilis on ethanol confirmed some of the above results. Biomass productivity of 2.5 g L(-1) h(-1) testifies about a good transfer capability of the column. Columns fitted with pneumatic and/or hydraulic energy input may be promising for aerobic fermentations considering their mass transfer and mixing characteristics.

  9. Proceedings of the NRDEC (Natick RD&E Center) Science Symposium Held on 2-4 June 1986 in Natick, Massachusetts. Volume 1

    DTIC Science & Technology

    1986-06-04

    turbulence as a means of increasing the external heat transfer coefficient. To evaluate the various evaporator des igns, each evaporator in turn was plumbed...water was pumped through the i ns ide surface while air flowed around t he outs i de . The amount of heat being transferred could be calculated by...intercept, (infinite wate r flow), the inside heat transfer coefficient can be de termined. The heat transfer res istances of the evaporator material

  10. Transfer function concept for ultrasonic characterization of material microstructures

    NASA Technical Reports Server (NTRS)

    Vary, A.; Kautz, H. E.

    1986-01-01

    The approach given depends on treating material microstructures as elastomechanical filters that have analytically definable transfer functions. These transfer functions can be defined in terms of the frequency dependence of the ultrasonic attenuation coefficient. The transfer function concept provides a basis for synthesizing expressions that characterize polycrystalline materials relative to microstructural factors such as mean grain size, grain-size distribution functions, and grain boundary energy transmission. Although the approach is nonrigorous, it leads to a rational basis for combining the previously mentioned diverse and fragmented equations for ultrasonic attenuation coefficients.

  11. Comparing four service delivery models for adolescent girls and young women through the ‘Girl Power’ study: protocol for a multisite quasi-experimental cohort study

    PubMed Central

    Rosenberg, Nora E; Pettifor, Audrey E; Myers, Laura; Phanga, Twambilile; Marcus, Rebecca; Madlingozi, Nomtha; Vansia, Dhrutika; Masters, Avril; Maseko, Bertha; Mtwisha, Lulu; Kachigamba, Annie; Tang, Jennifer; Hosseinipour, Mina C; Bekker, Linda-Gail

    2017-01-01

    Introduction In sub-Saharan Africa, adolescent girls and young women (AGYW) face a range of sexual and reproductive health (SRH) challenges. Clinical, behavioural and structural interventions have each reduced these risks and improved health outcomes. However, combinations of these interventions have not been compared with each other or with no intervention at all. The ‘Girl Power’ study is designed to systematically make these comparisons. Methods and analysis Four comparable health facilities in Malawi and South Africa (n=8) were selected and assigned to one of the following models of care: (1) Standard of care: AGYW can receive family planning, HIV testing and counselling (HTC), and sexually transmitted infection (STI) syndromic management in three separate locations with three separate queues with the general population. No youth-friendly spaces, clinical modifications or trainings are offered, (2) Youth-Friendly Health Services (YFHS): AGYW are meant to receive integrated family planning, HTC and STI services in dedicated youth spaces with youth-friendly modifications and providers trained in YFHS, (3) YFHS+behavioural intervention (BI): In addition to YFHS, AGYW can attend 12 monthly theory-driven, facilitator-led, interactive sessions on health, finance and relationships, (4) YFHS+BI+conditional cash transfer (CCT): in addition to YFHS and BI, AGYW receive up to 12 CCTs conditional on monthly BI session attendance. At each clinic, 250 AGYW 15–24 years old (n=2000 total) will be consented, enrolled and followed for 1 year. Each participant will complete a behavioural survey at enrolment, 6 months and 12 months . All clinical, behavioural and CCT services will be captured. Outcomes of interest include uptake of each package element and reduction in HIV risk behaviours. A qualitative substudy will be conducted. Ethics/dissemination This study has received ethical approval from the University of North Carolina Institutional Review Board, the University of Cape Town Human Research Ethics Committee and Malawi’s National Health Sciences Research Committee. Study plans, processes and findings will be disseminated to stakeholders, in peer-reviewed journals and at conferences. PMID:29247104

  12. Assessing the environmental impact of energy production from hydrochar generated via hydrothermal carbonization waste management

    USDA-ARS?s Scientific Manuscript database

    Hydrothermal carbonization (HTC) is a relatively low temperature thermal conversion process that is gaining significant attention as a sustainable and environmentally beneficial approach for the transformation of biomass and waste streams to value-added products. Although there are numerous studies ...

  13. Portable Low-Volume Therapy for Severe Blood Loss

    DTIC Science & Technology

    2012-06-01

    be reflected in Htc as well. Classic changes in plasma electrolyte concentration during hemorrhagic shock include hyperkalemia [17, 18] and...comparison with treatment no. 1 (pɘ.05), treatment no. 2 (pɘ.05), and treatment no. 3 (pɘ.05). Because the hyperkalemia and hyponatremia in

  14. Fluid dynamics and convective heat transfer in impinging jets through implementation of a high resolution liquid crystal technique

    NASA Technical Reports Server (NTRS)

    Kim, K.; Wiedner, B.; Camci, C.

    1993-01-01

    A combined convective heat transfer and fluid dynamics investigation in a turbulent round jet impinging on a flat surface is presented. The experimental study uses a high resolution liquid crystal technique for the determination of the convective heat transfer coefficients on the impingement plate. The heat transfer experiments are performed using a transient heat transfer method. The mean flow and the character of turbulent flow in the free jet is presented through five hole probe and hot wire measurements, respectively. The flow field character of the region near the impingement plate plays an important role in the amount of convective heat transfer. Detailed surveys obtained from five hole probe and hot wire measurements are provided. An extensive validation of the liquid crystal based heat transfer method against a conventional technique is also presented. After a complete documentation of the mean and turbulent flow field, the convective heat transfer coefficient distributions on the impingement plate are presented. The near wall of the impingement plate and the free jet region is treated separately. The current heat transfer distributions are compared to other studies available from the literature. The present paper contains complete sets of information on the three dimensional mean flow, turbulent velocity fluctuations, and convective heat transfer to the plate. The experiments also prove that the present nonintrusive heat transfer method is highly effective in obtaining high resolution heat transfer maps with a heat transfer coefficient uncertainty of 5.7 percent.

  15. Film Boiling Heat Transfer Properties of Liquid Hydrogen in Natural Convection

    NASA Astrophysics Data System (ADS)

    Horie, Y.; Shirai, Y.; Shiotsu, M.; Matsuzawa, T.; Yoneda, K.; Shigeta, H.; Tatsumoto, H.; Hata, K.; Naruo, Y.; Kobayashi, H.; Inatani, Y.

    Film boiling heat transfer properties of LH2 for various pressures and subcooling conditions were measured by applying electric current to give an exponential heat input to a PtCo wire with a diameter of 1.2 mm submerged in LH2. The heated wire was set to be horizontal to the ground. The heat transfer coefficient in the film boiling region was higher for higher pressure and higher subcooling. The experimental results are compared with the equation of pool film boiling heat transfer. It is confirmed that the pool film boiling heat transfer coefficients in LH2 can be expressed by this equation.

  16. The effect of free-stream turbulence on heat transfer from a flat plate

    NASA Technical Reports Server (NTRS)

    Sugawara, Sugao; Sato, Takashi; Komatsu, Hiroyasu; Osaka, Hiroichi

    1958-01-01

    Turbulence was generated by using screens, and the turbulence percentage was measured by a hot-wire anemometer both in the boundary layer and the free stream. The local heat-transfer coefficient was measured at 12 locations along the plate for the cases of various turbulence levels. The transition Reynolds number from laminar to turbulent flow decreases as the main-stream turbulence level increases. In the range of laminar heat transfer the effect of turbulence in the main flow was not great, but in the range of turbulent heat transfer the heat-transfer coefficient increases according to the increase of turbulence.

  17. Experimental Study on Flow Boiling of Carbon Dioxide in a Horizontal Microfin Tube

    NASA Astrophysics Data System (ADS)

    Kuwahara, Ken; Ikeda, Soshi; Koyama, Shigeru

    This paper deals with the experimental study on flow boiling heat transfer of carbon dioxide in a micro-fin tube. The geometrical parameters of micro-fin tube used in this study are 6.07 mm in outer diameter, 5.24 mm in average inner diameter, 0.256 mm in fin height, 20.4 in helix angle, 52 in number of grooves and 2.35 in area expansion ratio. Flow patterns and heat transfer coefficients were measured at 3-5 MPa in pressure, 300-540 kg/(m2s) in mass velocity and -5 to 15 °C in CO2 temperature. Flow patterns of wavy flow, slug flow and annular flow were observed. The measured heat transfer coefficients of micro-fin tube were 10-40 kW/(m2K). Heat transfer coefficients were strongly influenced by pressure.

  18. Film condensation in a horizontal rectangular duct

    NASA Technical Reports Server (NTRS)

    Lu, Qing; Suryanarayana, N. V.

    1992-01-01

    Condensation heat transfer in an annular flow regime with and without interfacial waves was experimentally investigated. The study included measurements of heat transfer rate with condensation of vapor flowing inside a horizontal rectangular duct and experiments on the initiation of interfacial waves in condensation, and adiabatic air-liquid flow. An analytical model for the condensation was developed to predict condensate film thickness and heat transfer coefficients. Some conclusions drawn from the study are that the condensate film thickness was very thin (less than 0.6 mm). The average heat transfer coefficient increased with increasing the inlet vapor velocity. The local heat transfer coefficient decreased with the axial distance of the condensing surface, with the largest change at the leading edge of the test section. The interfacial shear stress, which consisted of the momentum shear stress and the adiabatic shear stress, appeared to have a significant effect on the heat transfer coefficients. In the experiment, the condensate flow along the condensing surface experienced a smooth flow, a two-dimensional wavy flow, and a three-dimensional wavy flow. In the condensation experiment, the local wave length decreased with the axial distance of the condensing surface and the average wave length decreased with increasing inlet vapor velocity, while the wave speed increased with increasing vapor velocity. The heat transfer measurements are reliable. And, the ultrasonic technique was effective for measuring the condensate film thickness when the surface was smooth or had waves of small amplitude.

  19. Heat Transfer at a Long Electrically-Simulated Water Wall in a Circulating Fluidised Bed

    NASA Astrophysics Data System (ADS)

    Sundaresan, R.; Kolar, Ajit Kumar

    In the present work, heat transfer measurements are reported in a 100mm square, 5.5 m tall, cold CFB. The test section is a 19 mm OD electrically heated heat transfer tube, 4.64 m tall (covering more than 80% of the CFB height), sandwiched between two equally tall dummy tubes of 19mm OD, thus simulating a water wall geometry, forming one wall of the CFB. Narrow cut sand particles of mean diameters 156, 256, and 362 micrometers, and a wide cut sample of mean diameter 265 micrometer were used as the bed material. The superficial gas velocity ranged from 4.2 to 8.2 m/s, and the solids recycle flux varied from 17 to 110 kg/m2s. Local heat transfer coefficient at the simulated water wall varies, as expected from a low value at the top of the riser to a high value at the bottom, with an interesting increasing and decreasing trend in between. The average heat transfer coefficients were compared with those available in open literature. Correlations for average heat transfer coefficient are presented, both in terms of an average suspension density and also in terms of important nondimensional numbers, namely, Froude number, relative solids flux and velocity ratio. Comparisons are also made with predictions of relevant heat transfer models. Based on the present fifty-five experimental data points, the following correlation was presented with a correlation coefficient of 0.862 and maximum error is ± 15 %.

  20. Correlation of laboratory and production freeze drying cycles.

    PubMed

    Kuu, Wei Y; Hardwick, Lisa M; Akers, Michael J

    2005-09-30

    The purpose of this study was to develop the correlation of cycle parameters between a laboratory and a production freeze-dryer. With the established correlation, key cycle parameters obtained using a laboratory dryer may be converted to those for a production dryer with minimal experimental efforts. In order to develop the correlation, it was important to consider the contributions from the following freeze-drying components: (1) the dryer, (2) the vial, and (3) the formulation. The critical parameters for the dryer are the shelf heat transfer coefficient and shelf surface radiation emissivity. The critical parameters for the vial are the vial bottom heat transfer coefficients (the contact parameter Kcs and separation distance lv), and vial top heat transfer coefficient. The critical parameter of the formulation is the dry layer mass transfer coefficient. The above heat and mass transfer coefficients were determined by freeze-drying experiments in conjunction with mathematical modeling. With the obtained heat and mass transfer coefficients, the maximum product temperature, Tbmax, during primary drying was simulated using a primary drying subroutine as a function of the shelf temperature and chamber pressure. The required shelf temperature and chamber pressure, in order to perform a successful cycle run without product collapse, were then simulated based on the resulting values of Tbmax. The established correlation approach was demonstrated by the primary drying of the model formulation 5% mannitol solution. The cycle runs were performed using a LyoStar dryer as the laboratory dryer and a BOC Edwards dryer as the production dryer. The determined normalized dried layer mass transfer resistance for 5% mannitol is expressed as RpN=0.7313+17.19l, where l is the receding dry layer thickness. After demonstrating the correlation approach using the model formulation 5% mannitol, a practical comparison study was performed for the actual product, the lactate dehydrogenase (LDH) formulation. The determined normalized dried layer mass transfer resistance for the LDH formulation is expressed as RpN=4.344+10.85l. The operational templates Tbmax and primary drying time were also generated by simulation. The cycle run for the LDH formulation using the Edwards production dryer verified that the cycle developed in a laboratory freeze-dryer was transferable at the production scale.

  1. A comparison of mass transfer coefficients between trickle-bed, hollow fiber membrane and stirred tank reactors.

    PubMed

    Orgill, James J; Atiyeh, Hasan K; Devarapalli, Mamatha; Phillips, John R; Lewis, Randy S; Huhnke, Raymond L

    2013-04-01

    Trickle-bed reactor (TBR), hollow fiber membrane reactor (HFR) and stirred tank reactor (STR) can be used in fermentation of sparingly soluble gasses such as CO and H2 to produce biofuels and bio-based chemicals. Gas fermenting reactors must provide high mass transfer capabilities that match the kinetic requirements of the microorganisms used. The present study compared the volumetric mass transfer coefficient (K(tot)A/V(L)) of three reactor types; the TBR with 3 mm and 6 mm beads, five different modules of HFRs, and the STR. The analysis was performed using O2 as the gaseous mass transfer agent. The non-porous polydimethylsiloxane (PDMS) HFR provided the highest K(tot)A/V(L) (1062 h(-1)), followed by the TBR with 6mm beads (421 h(-1)), and then the STR (114 h(-1)). The mass transfer characteristics in each reactor were affected by agitation speed, and gas and liquid flow rates. Furthermore, issues regarding the comparison of mass transfer coefficients are discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. VOLATILIZATION OF ALKYLBENZENES FROM WATER.

    USGS Publications Warehouse

    Rathbun, R.E.; Tai, D.Y.

    1985-01-01

    Volatilization is a physical process of importance in determining the fate of many organic compounds in streams and rivers. This process is frequently described by the conceptual-two-film model. The model assumes uniformly mixed water and air phases separated by thin films of water and air in which mass transfer is by molecular diffusion. Mass-transfer coefficients for the water and air films are related to an overall mass-transfer coefficient for volatilization through the Henry's law constant.

  3. An Assessment of the General Applicability of the Relationship Between Nucleation of CO Bubbles and Mass Transfer of Phosphorus in Liquid Iron Alloys

    NASA Astrophysics Data System (ADS)

    Gu, Kezhuan; Dogan, Neslihan; Coley, Kenneth S.

    2018-06-01

    The current paper seeks to demonstrate the general applicability of the authors' recently developed treatment of surface renewal during decarburization of Fe-C-S alloys and its effect on the mass transport of phosphorus in the metal phase. The proposed model employs a quantitative model of CO bubble nucleation in the metal to predict the rate of surface renewal, which can then in turn be used to predict the mass-transfer coefficient for phosphorus. A model of mixed transport control in the slag and metal phases was employed to investigate the dephosphorization kinetics between a liquid iron alloy and oxidizing slag. Based on previous studies of the mass-transfer coefficient of FeO in the slag, it was possible to separate the mass transfer coefficient of phosphorus in metal phase, km , from the overall mass-transfer coefficient k_{{o}} . Using this approach, km was investigated under a wide range of conditions and shown to be represented reasonably by the mechanism proposed. The mass-transfer model was tested against results from the literature over a wide range of conditions. The analysis showed that the FeO content in the slag, silicon in the metal and the experimental temperature have strong impact on, km , almost entirely because of their effect on decarburization behavior.

  4. Comparison of heat transfer in liquid and slush nitrogen by numerical simulation of cooling rates for French straws used for sperm cryopreservation.

    PubMed

    Sansinena, M; Santos, M V; Zaritzky, N; Chirife, J

    2012-05-01

    Slush nitrogen (SN(2)) is a mixture of solid nitrogen and liquid nitrogen, with an average temperature of -207 °C. To investigate whether plunging a French plastic straw (commonly used for sperm cryopreservation) in SN(2) substantially increases cooling rates with respect to liquid nitrogen (LN(2)), a numerical simulation of the heat conduction equation with convective boundary condition was used to predict cooling rates. Calculations performed using heat transfer coefficients in the range of film boiling confirmed the main benefit of plunging a straw in slush over LN(2) did not arise from their temperature difference (-207 vs. -196 °C), but rather from an increase in the external heat transfer coefficient. Numerical simulations using high heat transfer (h) coefficients (assumed to prevail in SN(2)) suggested that plunging in SN(2) would increase cooling rates of French straw. This increase of cooling rates was attributed to a less or null film boiling responsible for low heat transfer coefficients in liquid nitrogen when the straw is placed in the solid-liquid mixture or slush. In addition, predicted cooling rates of French straws in SN(2) tended to level-off for high h values, suggesting heat transfer was dictated by heat conduction within the liquid filled plastic straw. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. An Assessment of the General Applicability of the Relationship Between Nucleation of CO Bubbles and Mass Transfer of Phosphorus in Liquid Iron Alloys

    NASA Astrophysics Data System (ADS)

    Gu, Kezhuan; Dogan, Neslihan; Coley, Kenneth S.

    2018-02-01

    The current paper seeks to demonstrate the general applicability of the authors' recently developed treatment of surface renewal during decarburization of Fe-C-S alloys and its effect on the mass transport of phosphorus in the metal phase. The proposed model employs a quantitative model of CO bubble nucleation in the metal to predict the rate of surface renewal, which can then in turn be used to predict the mass-transfer coefficient for phosphorus. A model of mixed transport control in the slag and metal phases was employed to investigate the dephosphorization kinetics between a liquid iron alloy and oxidizing slag. Based on previous studies of the mass-transfer coefficient of FeO in the slag, it was possible to separate the mass transfer coefficient of phosphorus in metal phase, km , from the overall mass-transfer coefficient k_{{o}} . Using this approach, km was investigated under a wide range of conditions and shown to be represented reasonably by the mechanism proposed. The mass-transfer model was tested against results from the literature over a wide range of conditions. The analysis showed that the FeO content in the slag, silicon in the metal and the experimental temperature have strong impact on, km , almost entirely because of their effect on decarburization behavior.

  6. Numerical Investigation of Nanofluid Laminar Forced Convective Heat Transfer inside an Equilateral Triangular Tube

    NASA Astrophysics Data System (ADS)

    Etminan, Amin; Harun, Zambri; Sharifian, Ahmad

    2017-01-01

    In this article distilled water and CuO particles with volume fraction of 1%, 2% and 4% are studied numerically. The steady state flow regime is considered laminar with Reynolds number of 100 and nanoparticles diameters (dp) are set in the range of 20 nm and 80 nm. The hydraulic diameter and the length of equilateral triangular channel are 8 mm and 1000 mm respectively. The problem is solved using finite volume method with constant heat flux for two sides and constant temperature for one side. Convective heat transfer coefficient, Nusselt number and convective heat transfer coefficient distribution on walls are investigated in details. The fluid flow is supposed to be one phase flow. It can be observed that nanofluid leads to a remarkable enhancement on heat transfer coefficient pressure loss through the channel. The computations reveal that the size of nanoparticles has no significant influence on heat transfer properties. Besides, the study shows a good agreement between current results and experimental data in the literatures.

  7. Gas transfer in a bubbly wake flow

    NASA Astrophysics Data System (ADS)

    Karn, A.; Gulliver, J. S.; Monson, G. M.; Ellis, C.; Arndt, R. E. A.; Hong, J.

    2016-05-01

    The present work reports simultaneous bubble size and gas transfer measurements in a bubbly wake flow of a hydrofoil, designed to be similar to a hydroturbine blade. Bubble size was measured by a shadow imaging technique and found to have a Sauter mean diameter of 0.9 mm for a reference case. A lower gas flow rate, greater liquid velocities, and a larger angle of attack all resulted in an increased number of small size bubbles and a reduced weighted mean bubble size. Bubble-water gas transfer is measured by the disturbed equilibrium technique. The gas transfer model of Azbel (1981) is utilized to characterize the liquid film coefficient for gas transfer, with one scaling coefficient to reflect the fact that characteristic turbulent velocity is replaced by cross-sectional mean velocity. The coefficient was found to stay constant at a particular hydrofoil configuration while it varied within a narrow range of 0.52-0.60 for different gas/water flow conditions.

  8. Saponification reaction system: a detailed mass transfer coefficient determination.

    PubMed

    Pečar, Darja; Goršek, Andreja

    2015-01-01

    The saponification of an aromatic ester with an aqueous sodium hydroxide was studied within a heterogeneous reaction medium in order to determine the overall kinetics of the selected system. The extended thermo-kinetic model was developed compared to the previously used simple one. The reaction rate within a heterogeneous liquid-liquid system incorporates a chemical kinetics term as well as mass transfer between both phases. Chemical rate constant was obtained from experiments within a homogeneous medium, whilst the mass-transfer coefficient was determined separately. The measured thermal profiles were then the bases for determining the overall reaction-rate. This study presents the development of an extended kinetic model for considering mass transfer regarding the saponification of ethyl benzoate with sodium hydroxide within a heterogeneous reaction medium. The time-dependences are presented for the mass transfer coefficient and the interfacial areas at different heterogeneous stages and temperatures. The results indicated an important role of reliable kinetic model, as significant difference in k(L)a product was obtained with extended and simple approach.

  9. Thermal performance of a prototype plate heat exchanger with minichannels under boiling conditions

    NASA Astrophysics Data System (ADS)

    Wajs, J.; Mikielewicz, D.; Fornalik-Wajs, E.

    2016-09-01

    To solve the problem and to meet the requirements of customers in the field of high heat fluxes transfer in compact units, a new design of plate heat exchanger with minichannels (minichannels PHE) was proposed. The aim was to construct a compact heat exchanger of high effectiveness for the purpose of household cogeneration ORC system. In this paper the experimental analysis of an assembled prototype of such compact heat exchanger was described. The attention was paid to its thermal performance and the heat transfer coefficients under the boiling conditions. Water and ethanol were chosen as working fluids. The maximal value of transferred heat flux was about 84 kW/m2, while of the overall heat transfer coefficient was about 4000 W/(m2K). Estimated values of heat transfer coefficient on the ethanol (boiling) side reached the level of 7500 W/(m2K). The results are promising in the light of future applications, for example in cogeneration ORC systems, however further systematic investigations are necessary.

  10. 78 FR 13673 - HTC America, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... modifying various pre-installed applications and components in order to differentiate its products from.... As the customized applications and components are pre-installed on the device, consumers do not... together, failed to provide reasonable and appropriate security in the design and customization of software...

  11. D.R.E.A.M.S: (Digital Rehabilitation Environment-Altering Medical System).

    PubMed

    Suvajdzic, Marko; Bihorac, Azra; Rashidi, Parisa

    2017-04-01

    In project D.R.E.A.M.S., we propose to develop and assess the feasibility of a novel and intelligent delirium-prevention system to address depression, pain, sleep, activity patterns and emotional states using the Emotiv Epoc+ I 14 Channel EEG", and HTC Vive VR set.

  12. Henry’s Law Constant and Overall Mass Transfer Coefficient for Formaldehyde Emission from Small Water Pools under Simulated Indoor Environmental Conditions

    EPA Science Inventory

    The Henry’s law constant (HLC) and the overall mass transfer coefficient are both important parameters for modeling formaldehyde emissions from aqueous solutions. In this work, the apparent HLCs for aqueous formaldehyde solutions were determined in the concentration range from 0....

  13. Effect of flow velocity on the process of air-steam condensation in a vertical tube condenser

    NASA Astrophysics Data System (ADS)

    Havlík, Jan; Dlouhý, Tomáš

    2018-06-01

    This article describes the influence of flow velocity on the condensation process in a vertical tube. For the case of condensation in a vertical tube condenser, both the pure steam condensation process and the air-steam mixture condensation process were theoretically and experimentally analyzed. The influence of steam flow velocity on the value of the heat transfer coefficient during the condensation process was evaluated. For the condensation of pure steam, the influence of flow velocity on the value of the heat transfer coefficient begins to be seen at higher speeds, conversely, this effect is negligible at low values of steam velocity. On the other hand, for the air-steam mixture condensation, the influence of flow velocity must always be taken into account. The flow velocity affects the water vapor diffusion process through non-condensing air. The presence of air significantly reduces the value of the heat transfer coefficient. This drop in the heat transfer coefficient is significant at low velocities; on the contrary, the decrease is relatively small at high values of the velocity.

  14. Diffusion relaxation times of nonequilibrium isolated small bodies and their solid phase ensembles to equilibrium states

    NASA Astrophysics Data System (ADS)

    Tovbin, Yu. K.

    2017-08-01

    The possibility of obtaining analytical estimates in a diffusion approximation of the times needed by nonequilibrium small bodies to relax to their equilibrium states based on knowledge of the mass transfer coefficient is considered. This coefficient is expressed as the product of the self-diffusion coefficient and the thermodynamic factor. A set of equations for the diffusion transport of mixture components is formulated, characteristic scales of the size of microheterogeneous phases are identified, and effective mass transfer coefficients are constructed for them. Allowing for the developed interface of coexisting and immiscible phases along with the porosity of solid phases is discussed. This approach can be applied to the diffusion equalization of concentrations of solid mixture components in many physicochemical systems: the mutual diffusion of components in multicomponent systems (alloys, semiconductors, solid mixtures of inert gases) and the mass transfer of an absorbed mobile component in the voids of a matrix consisting of slow components or a mixed composition of mobile and slow components (e.g., hydrogen in metals, oxygen in oxides, and the transfer of molecules through membranes of different natures, including polymeric).

  15. The Determination of Soil-plant Transfer Coefficients of Cesium-137 and Other Elements by γ-Ray Measurement and PIXE Analysis, for use in the Remediation of Fukushima

    NASA Astrophysics Data System (ADS)

    Ishii, K.; Fujita, A.; Toyama, S.; Terakawa, A.; Matsuyama, S.; Arai, H.; Osada, N.; Takyu, S.; Matsuyama, T.; Koshio, S.; Watanabe, K.; Ito, S.; Kasahara, K.

    Edible wild plants growing in the area around the Fukushima Daiichi nuclear power plant remain contaminated. It is important to identify plants with low levels of contamination for the restoration of agriculture in the area. We collected specimens of 10 wild plant species growing in Iitate village which is one of the most highly contaminated areas and also sampled the soil beneath each plant. We measured the specific activity of 137Cs and the concentrations of Na, Mg, Al, Si, P, S, K, Ca, Fe, Zn, Rb and Sr in these samples using a germanium detector and PIXE analysis, respectively. We compared the soil-plant transfer coefficient of 137Cs with those of each element and determined their correlation with 137Cs. It was found that a low Sr transfer coefficient could be used to determine the plants with a low 137Cs transfer coefficient. We suggest that PIXE analysis is a useful analysis technique for agricultural remediation projects in highly contaminated areas around the Fukushima Daiichi nuclear power plant.

  16. An empirical investigation on thermal characteristics and pressure drop of Ag-oil nanofluid in concentric annular tube

    NASA Astrophysics Data System (ADS)

    Abbasian Arani, A. A.; Aberoumand, H.; Aberoumand, S.; Jafari Moghaddam, A.; Dastanian, M.

    2016-08-01

    In this work an experimental study on Silver-oil nanofluid was carried out in order to present the laminar convective heat transfer coefficient and friction factor in a concentric annulus with constant heat flux boundary condition. Silver-oil nanofluid prepared by Electrical Explosion of Wire technique with no nanoparticles agglomeration during nanofluid preparation process and experiments. The average sizes of particles were 20 nm. Nanofluids with various particle Volume fractions of 0.011, 0.044 and 0.171 vol% were employed. The nanofluid flowing between the tubes is heated by an electrical heating coil wrapped around it. The effects of different parameters such as flow Reynolds number, tube diameter ratio and nanofluid particle concentration on heat transfer coefficient are studied. Results show that, heat transfer coefficient increased by using nanofluid instead of pure oil. Maximum enhancement of heat transfer coefficient occurs in 0.171 vol%. In addition the results showed that, there are slight increases in pressure drop of nanofluid by increasing the nanoparticle concentration of nanofluid in compared to pure oil.

  17. The effect of heating direction on flow boiling heat transfer of R134a in micro-channels

    NASA Astrophysics Data System (ADS)

    Xu, Mingchen; Jia, Li; Dang, Chao; Peng, Qi

    2017-04-01

    This paper presents effects of heating directions on heat transfer performance of R134a flow boiling in micro- channel heat sink. The heat sink has 30 parallel rectangular channels with cross-sectional dimensions of 500μm width 500μm depth and 30mm length. The experimental operation condition ranges of the heat flux and the mass flux were 13.48 to 82.25 W/cm2 and 373.3 to 1244.4 kg/m2s respectively. The vapor quality ranged from 0.07 to 0.93. The heat transfer coefficients of top heating and bottom heating both were up to 25 kW/m2 K. Two dominate transfer mechanisms of nucleate boiling and convection boiling were observed according to boiling curves. The experimental results indicated that the heat transfer coefficient of bottom heating was 13.9% higher than top heating in low heat flux, while in high heat flux, the heat transfer coefficient of bottom heating was 9.9%.higher than the top heating, because bubbles were harder to divorce the heating wall. And a modified correlation was provided to predict heat transfer of top heating.

  18. Measurement and modelling of forced convective heat transfer coefficient and pressure drop of Al2O3- and SiO2-water nanofluids

    NASA Astrophysics Data System (ADS)

    Julia, J. E.; Hernández, L.; Martínez-Cuenca, R.; Hibiki, T.; Mondragón, R.; Segarra, C.; Jarque, J. C.

    2012-11-01

    Forced convective heat transfer coefficient and pressure drop of SiO2- and Al2O3-water nanofluids were characterized. The experimental facility was composed of thermal-hydraulic loop with a tank with an immersed heater, a centrifugal pump, a bypass with a globe valve, an electromagnetic flow-meter, a 18 kW in-line pre-heater, a test section with band heaters, a differential pressure transducer and a heat exchanger. The test section consists of a 1000 mm long aluminium pipe with an inner diameter of 31.2 mm. Eighteen band heaters were placed all along the test section in order to provide a uniform heat flux. Heat transfer coefficient was calculated measuring fluid temperature using immersed thermocouples (Pt100) placed at both ends of the test section and surface thermocouples in 10 axial locations along the test section (Pt1000). The measurements have been performed for different nanoparticles (Al2O3 and SiO2 with primary size of 11 nm and 12 nm, respectively), volume concentrations (1% v., 5% v.), and flow rates (3 103Re<105). Maximum heat transfer coefficient enhancement (300%) and pressure drop penalty (1000%) is obtained with 5% v. SiO2 nanofluid. Existing correlations can predict, at least in a first approximation, the heat transfer coefficient and pressure drop of nanofluids if thermal conductivity, viscosity and specific heat were properly modelled.

  19. Computational Fluid Dynamics Based Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

    NASA Technical Reports Server (NTRS)

    Yang, H. Q.; West, Jeff

    2015-01-01

    Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from: inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. The work presented under this task uses the first-principles based Computational Fluid Dynamics (CFD) technique to compute heat transfer from tank wall to the cryogenic fluids, and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between tank wall and cryogenic propellant, and that between tank wall and ullage gas were then simulated. The results showed that commonly used heat transfer correlations for either vertical or horizontal plate over predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

  20. CFD Extraction of Heat Transfer Coefficient in Cryogenic Propellant Tanks

    NASA Technical Reports Server (NTRS)

    Yang, H. Q.; West, Jeff

    2015-01-01

    Current reduced-order thermal model for cryogenic propellant tanks is based on correlations built for flat plates collected in the 1950's. The use of these correlations suffers from inaccurate geometry representation; inaccurate gravity orientation; ambiguous length scale; and lack of detailed validation. This study uses first-principles based CFD methodology to compute heat transfer from the tank wall to the cryogenic fluids and extracts and correlates the equivalent heat transfer coefficient to support reduced-order thermal model. The CFD tool was first validated against available experimental data and commonly used correlations for natural convection along a vertically heated wall. Good agreements between the present prediction and experimental data have been found for flows in laminar as well turbulent regimes. The convective heat transfer between the tank wall and cryogenic propellant, and that between the tank wall and ullage gas were then simulated. The results showed that the commonly used heat transfer correlations for either vertical or horizontal plate over-predict heat transfer rate for the cryogenic tank, in some cases by as much as one order of magnitude. A characteristic length scale has been defined that can correlate all heat transfer coefficients for different fill levels into a single curve. This curve can be used for the reduced-order heat transfer model analysis.

  1. Determination of the oil distribution in a hermetic compressor using numerical simulation

    NASA Astrophysics Data System (ADS)

    Posch, S.; Hopfgartner, J.; Berger, E.; Zuber, B.; Almbauer, R.; Schöllauf, P.

    2017-08-01

    In addition to the reduction of friction the oil in a hermetic compressor is very important for the transfer of heat from hot parts to the compressor shell. The simulation of the oil distribution in a hermetic reciprocating compressor for refrigeration application is shown in the present work. Using the commercial Computational Fluid Dynamics (CFD) software ANSYS Fluent, the oil flow inside the compressor shell from the oil pump outlet to the oil sump is calculated. A comprehensive overview of the used models and the boundary conditions is given. After reaching steady-state conditions the oil covered surfaces are analysed concerning heat transfer coefficients. The gained heat transfer coefficients are used as input parameters for a thermal model of a hermetic compressor. An increase in accuracy of the thermal model with the simulated heat transfer coefficients compared to values from literature is shown by model validation with experimental data.

  2. Heat Transfer of HC290-OIL Mixtures in a Horizontal Condensing Micro-Fin Tube

    NASA Astrophysics Data System (ADS)

    Tong, M. W.; Dong, M. L.; Li, Y.

    Heat transfer coefficients was experimentally determined for a horizontal micro-fin tube (2m in length, 11.44mm ID) with HC290-oil mixtures. The oil is Suniso 3GS, which is a widely used oil in refrigerant systems. The micro-fin tube is a internally enhanced tube, which has 60 fins with a height of 0.25mm and 20° spiral angle. The condensation temperatures varied from 40° to 45° and the refrigerant mass flux was varied from 40kg/(m2s) to 220kg/(m2s). The results showed that the mean condensation heat transfer coefficients on the test section (inlet vapor quality 1, outlet vapor quality 0.1~0.25) decreased as the oil concentrations were increased and the condensation temperature had negligible effect on the heat transfer coefficients.

  3. Heat transfer and pressure drop of condensation of hydrocarbons in tubes

    NASA Astrophysics Data System (ADS)

    Fries, Simon; Skusa, Severin; Luke, Andrea

    2018-03-01

    The heat transfer coefficient and pressure drop are investigated for propane. Two different mild steel plain tubes and saturation pressures are considered for varying mass flux and vapour quality. The pressure drop is compared to the Friedel-Correlation with two different approaches to determine the friction factor. The first is calculation as proposed by Friedel and the second is through single phase pressure drop investigations. For lower vapour qualities the experimental results are in better agreement with the approach of the calculated friction factor. For higher vapour qualities the experimental friction factor is more precise. The pressure drop increases for a decreasing tube diameter and saturation pressure. The circumferential temperature profile and heat transfer coefficients are shown for a constant vapour quality at varying mass fluxes. The subcooling is highest for the bottom of the tube and lowest for the top. The average subcooling as well as the circumferential deviation decreases for rising mass fluxes. The averaged heat transfer coefficients are compared to the model proposed by Thome and Cavallini. The experimental results are in good agreement with both correlations, however the trend is better described with the correlation from Thome. The experimental heat transfer coefficients are under predicted by Thome and over predicted by Cavallini.

  4. Film cooling performance of a row of dual-fanned holes at various injection angles

    NASA Astrophysics Data System (ADS)

    Li, Guangchao; Wang, Haofeng; Zhang, Wei; Kou, Zhihai; Xu, Rangshu

    2017-10-01

    Film cooling performance about a row of dual-fanned holes with injection angles of 30°, 60 ° and 90° were experimentally investigated at blowing ratios of 1.0 and 2.0. Dual-fanned hole is a novel shaped hole which has both inlet expansion and outlet expansion. A transient thermochromic liquid crystal technique was used to reveal the local values of film cooling effectiveness and heat transfer coefficient. The results show that injection angles have strong influence on the two dimensional distributions of film cooling effectiveness and heat transfer coefficient. For the small injection angle of 30 degree and small blowing ratio of 1.0, there is only a narrow spanwise region covered with film. The increase of injection angle and blowing ratio both leads to the enhanced spanwise film diffusion, but reduced local cooling ability far away from the hole. Injection angles have comprehensive influence on the averaged film cooling effectiveness for various x/d locations. As injection angles are 30 and 60 degree, two bands of high heat transfer coefficients are found in mixing region of the gas and coolant. As injection angle increases to 90 degree, the mixing leads to the enhanced heat transfer region near the film hole. The averaged heat transfer coefficient increases with the increase of injection angle.

  5. The impact of bed temperature on heat transfer characteristic between fluidized bed and vertical rifled tubes

    NASA Astrophysics Data System (ADS)

    Blaszczuk, Artur; Nowak, Wojciech

    2016-10-01

    In the present work, the heat transfer study focuses on assessment of the impact of bed temperature on the local heat transfer characteristic between a fluidized bed and vertical rifled tubes (38mm-O.D.) in a commercial circulating fluidized bed (CFB) boiler. Heat transfer behavior in a 1296t/h supercritical CFB furnace has been analyzed for Geldart B particle with Sauter mean diameter of 0.219 and 0.246mm. The heat transfer experiments were conducted for the active heat transfer surface in the form of membrane tube with a longitudinal fin at the tube crest under the normal operating conditions of CFB boiler. A heat transfer analysis of CFB boiler with detailed consideration of the bed-to-wall heat transfer coefficient and the contribution of heat transfer mechanisms inside furnace chamber were investigated using mechanistic heat transfer model based on cluster renewal approach. The predicted values of heat transfer coefficient are compared with empirical correlation for CFB units in large-scale.

  6. Thermal modulation voltammetry with laser heating at an aqueous|nitrobenzene solution microinterface: determination of the standard entropy changes of transfer for tetraalkylammonium ions.

    PubMed

    Hinoue, Teruo; Ikeda, Eiji; Watariguchi, Shigeru; Kibune, Yasuyuki

    2007-01-01

    Thermal modulation voltammetry (TMV) with laser heating was successfully performed at an aqueous|nitrobenzene (NB) solution microinterface, by taking advantage of the fact that laser light with a wavelength of 325.0 nm is optically transparent to the aqueous solution but opaque to the NB solution. When the laser beam impinges upon the interface from the aqueous solution side, a temperature is raised around the interface through the thermal diffusion subsequent to the light-to-heat conversion following the optical absorption by the NB solution near the interface. Based on such a principle, we achieved a fluctuating temperature perturbation around the interface for TMV by periodically irradiating the interface with the laser beam. On the other hand, the fluctuating temperature perturbation has influence on currents for transfer of an ion across the interface to produce fluctuating currents synchronized with the perturbation through temperature coefficients of several variables concerning the transfer, such as the standard transfer potential and the diffusion coefficient of the ion. Consequently, TMV has the possibility of providing information about the standard entropy change of transfer corresponding to a temperature coefficient of the standard transfer potential and a temperature coefficient of the diffusion coefficient. In this work, the aqueous|NB solution interface of 30 microm in diameter was irradiated with the laser beam at 10 Hz, and the currents synchronized with the periodical irradiation were recorded as a function of the potential difference across the interface in order to construct a TM voltammogram. TM voltammograms were measured for transfer of tetramethylammonium, tetraethylammonium, tetrapropylammonium, and tetra-n-butylammonium ions from the aqueous solution to the NB solution, and the standard entropy change of transfer was determined for each ion, according to an analytical procedure based on a mathematical expression of the TM voltammogram. Comparison of the values obtained in this work with the literature values has proved that TMV with laser heating is available for the determination of the standard entropy change of transfer for an ion.

  7. An experimental investigation of the effects of spiral angle on the evaporation heat transfer coefficients in microfin tubes with visualization technique

    NASA Astrophysics Data System (ADS)

    Oh, Se-Yoon

    A smooth tube and five microfin tubes were tested, and evaporation heat transfer coefficients were measured and compared for mass fluxes, 50, 100 and 200 kg/m2 s, and heat fluxes, 5, 10 and 20 kW/m 2, with Refrigerant 134a as a working fluid. The evaporation heat transfer coefficients at quality 0.5 were compared among the smooth and five microfin tubes with spiral angles 6, 12, 18, 25 and 44 degrees. The effect of the spiral angle on the heat transfer coefficients was examined. It was found that the optimal spiral angle where the maximum heat transfer coefficient occurs, mainly depends on mass flux. The optimal spiral angle was 18 degrees for G=50 kg/m2 s, and 6 degrees for G=100 and 200 kg/m 2 s. A borescope was used to visualize the flow on the inside wall of test tubes. The purpose was to find out the effect of the grooves on the liquid flow in microfin tubes and to explain the mechanism of heat transfer enhancement. Temperatures on the tube wall were measured at the same axial location as the imaging sensor of the borescope, and were related to the behavior of the liquid flow on the inside wall of the tubes. The liquid flow in the grooves on the wall was found to be the most important factor in enhancing heat transfer coefficients. The liquid flowed upward along the grooves and covered the upper inside wall of the microfin tubes at G=50 kg/m2 s. When heat flux increases, the liquid flow was found at a higher position. Both liquid viscosity and surface tension decrease, when temperature increases. Thus, the lower viscosity at higher heat flux facilitated the upward motion of the liquid flow in the grooves, so that the momentum force as well as the capillary effect was found to push the liquid along the grooves.* *A CD is included with dissertation containing video clips in avi format which can be viewed with media player.

  8. Passive Nosetip Technology (PANT) Program. Volume 17. Computer User’s Manual: Erosion Shape (EROS) Computer Code

    DTIC Science & Technology

    1974-12-01

    as a series of sections, eacN represent- ing one pressure and each preceding the corresponding pressure group of the sur- face thermochemistry deck...groups together make up the surface thermochemistry deck. Within each pressure group the transfer coefficient values will be ordered. Within each transfer...values in each pressure group may not exceed 5 but may be only 1. If no kinetics effects are to be considered a transfer coefficient of zero is acceptable

  9. Unsteady Analysis of Blade and Tip Heat Transfer as Influenced by the Upstream Momentum and Thermal Wakes

    NASA Technical Reports Server (NTRS)

    Ameri, Ali A.; Rigby, David L.; Steinthorsson, Erlendur; Heidmann, James D.; Fabian, John C.

    2008-01-01

    The effect of the upstream wake on the blade heat transfer has been numerically examined. The geometry and the flow conditions of the first stage turbine blade of GE s E3 engine with a tip clearance equal to 2 percent of the span was utilized. Based on numerical calculations of the vane, a set of wake boundary conditions were approximated, which were subsequently imposed upon the downstream blade. This set consisted of the momentum and thermal wakes as well as the variation in modeled turbulence quantities of turbulence intensity and the length scale. Using a one-blade periodic domain, the distributions of unsteady heat transfer rate on the turbine blade and its tip, as affected by the wake, were determined. Such heat transfer coefficient distribution was computed using the wall heat flux and the adiabatic wall temperature to desensitize the heat transfer coefficient to the wall temperature. For the determination of the wall heat flux and the adiabatic wall temperatures, two sets of computations were required. The results were used in a phase-locked manner to compute the unsteady or steady heat transfer coefficients. It has been found that the unsteady wake has some effect on the distribution of the time averaged heat transfer coefficient on the blade and that this distribution is different from the distribution that is obtainable from a steady computation. This difference was found to be as large as 20 percent of the average heat transfer on the blade surface. On the tip surface, this difference is comparatively smaller and can be as large as four percent of the average.

  10. Mass and heat transfer in crushed oil shale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carley, J.F.; Ott, L.L.; Swecker, J.L.

    1995-03-01

    Studies of heat and mass transfer in packed beds, which disagree substantially in their findings, have nearly all been done with beds of regular particles of uniform size, whereas oil-shale retorting involves particles of diverse irregular shapes and sizes. The authors, in 349 runs, measured mass-transfer rates front naphthalene particles buried in packed beds by passing through air at room temperature. An exact catalog between convection of heat and mass makes it possible to infer heat-transfer coefficients from measured mass-transfer coefficients and fluid properties. Some beds consisted of spheres, naphthalene and inert, of the same, contrasting or distributed sizes. Inmore » some runs, naphthalene spheres were buried in beds of crushed shale, some in narrow screen ranges and others with a wide size range. In others, naphthalene lozenges of different shapes were buried in beds of crushed shale in various bed axis orientations. This technique permits calculation of the mass-transfer coefficient for each active particle in the bed rather than, as in most past studies, for the bed as a whole. The data are analyzed by the traditional correlation of Colburn j{sub D} vs. Reynolds number and by multiple regression of the mass-transfer coefficient on air rate, sizes of active and inert particles, void fraction, and temperature. Principal findings are: local Reynolds number should be based on the active-particle size, not the average for the whole bed; differences between shallow and deep beds are not appreciable; mass transfer is 26% faster for spheres and lozenges buried in shale than in all-sphere beds; orientation of lozenges in shale beds has little or no effect on mass-transfer rate; and for mass or heat transfer in shale beds, log(j{center_dot}{epsilon}) = {minus}0.0747 - 0.6344 log N{sub Re} + 0. 0592 log {sup 2} N{sub Re}.« less

  11. An investigation on near wall transport characteristics in an adiabatic upward gas-liquid two-phase slug flow

    NASA Astrophysics Data System (ADS)

    Zheng, Donghong; Che, Defu

    2007-08-01

    The near-wall transport characteristics, inclusive of mass transfer coefficient and wall shear stress, which have a great effect on gas-liquid two-phase flow induced internal corrosion of low alloy pipelines in vertical upward oil and gas mixing transport, have been both mechanistically and experimentally investigated in this paper. Based on the analyses on the hydrodynamic characteristics of an upward slug unit, the mass transfer in the near wall can be divided into four zones, Taylor bubble nose zone, falling liquid film zone, Taylor bubble wake zone and the remaining liquid slug zone; the wall shear stress can be divided into two zones, the positive wall shear stress zone associated with the falling liquid film and the negative wall shear stress zone associated with the liquid slug. Based on the conventional mass transfer and wall shear stress characteristics formulas of single phase liquid full-pipe turbulent flow, corrected normalized mass transfer coefficient formula and wall shear stress formula are proposed. The calculated results are in good agreement with the experimental data. The shear stress and the mass transfer coefficient in the near wall zone are increased with the increase of superficial gas velocity and decreased with the increase of superficial liquid velocity. The mass transfer coefficients in the falling liquid film zone and the wake zone of leading Taylor bubble are lager than those in the Taylor bubble nose zone and the remaining liquid slug zone, and the wall shear stress associated falling liquid film is larger than that associated the liquid slug. The mass transfer coefficient is within 10-3 m/s, and the wall shear stress below 103 Pa. It can be concluded that the alternate wall shear stress due to upward gas-liquid slug flow is considered to be the major cause of the corrosion production film fatigue cracking.

  12. Gas turbine blade film cooling and blade tip heat transfer

    NASA Astrophysics Data System (ADS)

    Teng, Shuye

    The detailed heat transfer coefficient and film cooling effectiveness distributions as well as the detailed coolant jet temperature profiles on the suction side of a gas turbine blade were measured using a transient liquid crystal image method and a traversing cold wire and thermocouple probe, respectively. The blade has only one row of film holes near the gill hole portion on the suction side of the blade. The hole geometries studied include standard cylindrical holes and holes with diffuser shaped exit portion (i.e. fanshaped holes and laidback fanshaped holes). Tests were performed on a five-blade linear cascade in a low-speed wind tunnel. The mainstream Reynolds number based on cascade exit velocity was 5.3 x 105. The upstream unsteady wakes were simulated using a spoke-wheel type wake generator. The wake Strouhal number was kept at 0 and 0.1. The coolant blowing ratio was varied from 0.4 to 1.2. Results show that both expanded holes have significantly improved thermal protection over the surface downstream of the ejection location, particularly at high blowing ratios. However, the expanded hole injections induce earlier boundary layer transition to turbulence and enhance heat transfer coefficients at the latter part of the blade suction surface. In general, the unsteady wake tends to reduce film cooling effectiveness. Measurements of detailed heat transfer coefficient distributions on a turbine blade tip were performed in the same wind tunnel facility as above. The central blade had a variable tip gap clearance. Measurements were made at three different tip gap clearances of about 1.1%, 2.1%, and 3% of the blade span. Static pressure distributions were measured in the blade mid-span and on the shroud surface. Detailed heat transfer coefficient distributions were measured on the blade tip surface. Results show that reduced tip clearance leads to reduced heat transfer coefficient over the blade tip surface. Results also show that reduced tip clearance tends to weaken the unsteady wake effect on blade tip heat transfer.

  13. DETERMINATION OF HEAT TRANSFER COEFFICIENTS FOR FRENCH PLASTIC SEMEN STRAW SUSPENDED IN STATIC NITROGEN VAPOR OVER LIQUID NITROGEN.

    PubMed

    Santo, M V; Sansinena, M; Chirife, J; Zaritzky, N

    2015-01-01

    The use of mathematical models describing heat transfer during the freezing process is useful for the improvement of cryopreservation protocols. A widespread practice for cryopreservation of spermatozoa of domestic animal species consists of suspending plastic straws in nitrogen vapor before plunging into liquid nitrogen. Knowledge of surface heat transfer coefficient (h) is mandatory for computational modelling; however, h values for nitrogen vapor are not available. In the present study, surface heat transfer coefficients for plastic French straws immersed in nitrogen vapor over liquid nitrogen was determined; vertical and horizontal positions were considered. Heat transfer coefficients were determined from the measurement of time-temperature curves and from numerical solution of heat transfer partial differential equation under transient conditions using finite elements. The h values experimentally obtained for horizontal and vertically placed straws were compared to those calculated using correlations based on the Nusselt number for natural convection. For horizontal straws the average obtained value was h=12.5 ± 1.2 W m(2) K and in the case of vertical straws h=16 ± 2.48 W m(2) K. The numerical simulation validated against experimental measurements, combined with accurate h values provides a reliable tool for the prediction of freezing curves of semen-filled straws immersed in nitrogen vapor. The present study contributes to the understanding of the cryopreservation techniques for sperm freezing based on engineering concepts, improving the cooling protocols and the manipulation of the straws.

  14. 75 FR 54854 - Wooden Bedroom Furniture From the People's Republic of China: Partial Rescission of Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... Hospitality Product Mfg., Co., Ltd. Shanghai Kent Furniture Co., Ltd. Shanghai Season Industry & Commerce Co... International, Ltd., Super Art Furniture Co., Ltd., Artwork Metal and Plastic Co., Ltd., Jibson Industries, Ltd... Hospitality, Inc. Changshu HTC Import & Export Co., Ltd. Chuan Fa Furniture Factory Contact Co., Ltd. Decca...

  15. 76 FR 58537 - In the Matter of Certain Personal Data and Mobile Communications Devices and Related Software...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-21

    ... subsystems. (HTC Pet. 30-35). (4) Whether the final ID's applications of the claim constructions for... below: (1) Whether the final ID's applications of the claim constructions for ``linking actions to the... has determined to review certain claim constructions, as well as the final ID's determinations...

  16. Hydrochar from sewage sludge and urban wastes as a peat replacement in growing media preparation

    NASA Astrophysics Data System (ADS)

    Álvarez, Maria Luisa; Méndez, Ana; Paz-Ferreiro, Jorge; Soler-Rovira, Pedro; García-Gil, Juan Carlos; Plaza, César; Gascó, Gabriel

    2016-04-01

    Nowadays, there is an important trend in Europe for peat replacement with biochar in growing media formulation in order to reduce the environmental impact of peat exploitation. Hydrothermal carbonization (HTC) is a thermochemical process of converting organic feedstock into a high carbon rich solid product named hydrochar. It is performed in water mild temperature (180-260°C) under pressure conditions (2-6MPa) for 5-250 min. The reaction pressure is not controlled in the process and is autogenic with the saturation vapour pressure of water corresponding to the reaction temperature. In recent years, the possibility of subjecting organic wastes to HTC has attracted the scientific community attention due to their interesting advantages over other thermal treatments such as pyrolysis, torrefaction or gasification. The aim of the present paper is to study the possible use of two hydrochars produced by Ingelia (Spain) from sewage sludge and urban waste treatment as growing media material in horticulture. For this, thermal, chemical and hydrophysical properties were determined and compared with that of brown commercial peat.

  17. 3H-tetracycline as a proxy for 41Ca for measuring dietary perturbations of bone resorption

    NASA Astrophysics Data System (ADS)

    Weaver, Connie; Cheong, Jennifer; Jackson, George; Elmore, David; McCabe, George; Martin, Berdine

    2007-06-01

    Our group is interested in evaluating early effects of dietary interventions on bone loss. Postmenopausal women lose bone following reduction in estrogen which leads to increased risk of fracture. Traditional means of monitoring bone loss and effectiveness of treatments include changes in bone density, which takes 6 months to years to observe effects, and changes in biochemical markers of bone turnover, which are highly variable and lack specificity. Prelabeling bone with 41Ca and measuring urinary 41Ca excretion with accelerator mass spectrometry provides a sensitive, specific, and rapid approach to evaluating effectiveness of treatment. To better understand 41Ca technology as a tool for measuring effective treatments on reducing bone resorption, we perturbed bone resorption by manipulating dietary calcium in rats. We used 3H-tetracycline (3H-TC) as a proxy for 41Ca and found that a single dose is feasible to study bone resorption. Suppression of bone resorption, as measured by urinary 3H-TC, by dietary calcium was observed in rats stabilized after ovariectomy, but not in recently ovariectomized rats.

  18. Toxicity evaluation of process water from hydrothermal carbonization of sugarcane industry by-products.

    PubMed

    Fregolente, Laís Gomes; Miguel, Thaiz Batista Azevedo Rangel; de Castro Miguel, Emilio; de Almeida Melo, Camila; Moreira, Altair Benedito; Ferreira, Odair Pastor; Bisinoti, Márcia Cristina

    2018-03-29

    Hydrothermal carbonization (HTC) is a thermochemical process carried out in an aqueous medium. It is capable of converting biomass into a solid, carbon-rich material (hydrochar), and producing a liquid phase (process water) which contains the unreactive feedstock and/or chemical intermediates from the carbonization reaction. The aim of this study was to evaluate the characteristics of process water generated by HTC from vinasse and sugarcane bagasse produced by sugarcane industry and to evaluate its toxicity to both marine (using Artemia salina as a model organism) and the terrestrial environment (through seed germination studies of maize, lettuce, and tomato). The experiments showed that concentrated process water completely inhibited germination of maize, lettuce, and tomato seeds. On the other hand, diluted process water was able to stimulate seedlings of maize and tomato and enhance root and shoot growth. For Artemia, the LC 50 indicated that the process water is practically non-toxic; however, morphological changes, especially damages to the digestive tube and antennas of Artemia, were observed for the concentration of 1000 mg C L -1 .

  19. Hydration properties and texture fingerprints of easy- and hard-to-cook bean varieties

    PubMed Central

    Kinyanjui, Peter K; Njoroge, Daniel M; Makokha, Anselimo O; Christiaens, Stefanie; Ndaka, Daniel S; Hendrickx, Marc

    2015-01-01

    The objective of this study was to understand the factors that affect the hydration and cooking profiles of different bean varieties. During this study, nine bean varieties were classified as either easy-to-cook (ETC) or hard-to-cook (HTC) based on a subjective finger pressing test and an objective cutting test. Rose coco, Red haricot, and Zebra beans were classified as ETC, while Canadian wonder, Soya fupi, Pinto, non-nodulating, Mwezi moja, Gwaku, and New mwezi moja were HTC. The effect of different soaking (pre)-treatments on the cooking behavior and/or water absorption of whole or dehulled beans was investigated. Dehulling, soaking in high pH and monovalent salt solutions reduced the cooking time of beans, while soaking in low pH and CaCl2 solutions increased the cooking time. Moisture uptake was faster in ETC and dehulled beans. Soaking at high temperatures also increased the hydration rate. The results point to pectin-related aspects and the rate of water uptake as possible factors that influence the cooking rate of beans. PMID:25650021

  20. Jet array impingement with crossflow-correlation of streamwise resolved flow and heat transfer distributions

    NASA Technical Reports Server (NTRS)

    Florschuetz, L. W.; Metzger, D. E.; Truman, C. R.

    1981-01-01

    Correlations for heat transfer coefficients for jets of circular offices and impinging on a surface parallel to the jet orifice plate are presented. The air, following impingement, is constrained to exit in a single direction along the channel formed by the jet orifice plate and the heat transfer (impingement) surface. The downstream jets are subjected to a crossflow originating from the upstream jets. Impingement surface heat transfer coefficients resolved to one streamwise jet orifice spacing, averaged across the channel span, are correlated with the associated individual spanwise orifice row jet and crossflow velocities, and with the geometric parameters.

  1. Beyond the standard two-film theory: Computational fluid dynamics simulations for carbon dioxide capture in a wetted wall column

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chao; Xu, Zhijie; Lai, Canhai

    The standard two-film theory (STFT) is a diffusion-based mechanism that can be used to describe gas mass transfer across liquid film. Fundamental assumptions of the STFT impose serious limitations on its ability to predict mass transfer coefficients. To better understand gas absorption across liquid film in practical situations, a multiphase computational fluid dynamics (CFD) model fully equipped with mass transport and chemistry capabilities has been developed for solvent-based carbon dioxide (CO 2) capture to predict the CO 2 mass transfer coefficient in a wetted wall column. The hydrodynamics is modeled using a volume of fluid method, and the diffusive andmore » reactive mass transfer between the two phases is modeled by adopting a one-fluid formulation. We demonstrate that the proposed CFD model can naturally account for the influence of many important factors on the overall mass transfer that cannot be quantitatively explained by the STFT, such as the local variation in fluid velocities and properties, flow instabilities, and complex geometries. The CFD model also can predict the local mass transfer coefficient variation along the column height, which the STFT typically does not consider.« less

  2. Beyond the standard two-film theory: Computational fluid dynamics simulations for carbon dioxide capture in a wetted wall column

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chao; Xu, Zhijie; Lai, Canhai

    The standard two-film theory (STFT) is a diffusion-based mechanism that can be used to describe gas mass transfer across liquid film. Fundamental assumptions of the STFT impose serious limitations on its ability to predict mass transfer coefficients. To better understand gas absorption across liquid film in practical situations, a multiphase computational fluid dynamics (CFD) model fully equipped with mass transport and chemistry capabilities has been developed for solvent-based carbon dioxide (CO2) capture to predict the CO2 mass transfer coefficient in a wetted wall column. The hydrodynamics is modeled using a volume of fluid method, and the diffusive and reactive massmore » transfer between the two phases is modeled by adopting a one-fluid formulation. We demonstrate that the proposed CFD model can naturally account for the influence of many important factors on the overall mass transfer that cannot be quantitatively explained by the STFT, such as the local variation in fluid velocities and properties, flow instabilities, and complex geometries. The CFD model also can predict the local mass transfer coefficient variation along the column height, which the STFT typically does not consider.« less

  3. Analysis of a self-propelling sheet with heat transfer through non-isothermal fluid in an inclined human cervical canal.

    PubMed

    Walait, Ahsan; Siddiqui, A M; Rana, M A

    2018-02-13

    The present theoretical analysis deals with biomechanics of the self-propulsion of a swimming sheet with heat transfer through non-isothermal fluid filling an inclined human cervical canal. Partial differential equations arising from the mathematical modeling of the proposed model are solved analytically. Flow variables like pressure gradient, propulsive velocity, fluid velocity, time mean flow rate, fluid temperature, and heat-transfer coefficients are analyzed for the pertinent parameters. Striking features of the pumping characteristics are explored. Propulsive velocity of the swimming sheet becomes faster for lower Froude number, higher Reynolds number, and for a vertical channel. Temperature and peak value of the heat-transfer coefficients below the swimming sheet showed an increase by the increment of Brinkmann number, inclination, pressure difference over wavelength, and Reynolds number whereas these quantities decrease with increasing Froude number. Aforesaid parameters have shown opposite effects on the peak value of the heat-transfer coefficients below and above the swimming sheet. Relevance of the current results to the spermatozoa transport with heat transfer through non-isothermal cervical mucus filling an inclined human cervical canal is also explored.

  4. Heat transfer performance of Al2O3/water nanofluids in a mini channel heat sink.

    PubMed

    Dominic, A; Sarangan, J; Suresh, S; Sai, Monica

    2014-03-01

    The high density heat removal in electronic packaging is a challenging task of modern days. Finding compact, energy efficient and cost effective methods of heat removal is being the interest of researchers. In the present work, mini channel with forced convective heat transfer in simultaneously developing regime is investigated as the heat transfer coefficient is inversely proportional to hydraulic diameter. Mini channel heat sink is made from the aluminium plate of 30 mm square with 8 mm thickness. It has 15 mini channel of 0.9 mm width, 1.3 mm height and 0.9 mm of pitch. DI water and water based 0.1% and 0.2% volume fractions of Al2O3/water nanofluids are used as coolant. The flow rates of the coolants are maintained in such a way that it is simultaneously developing. Reynolds number is varied from 400 to 1600 and heat input is varied from 40 W to 70 W. The results showed that heat transfer coefficient is more than the heat transfer coefficient of fully developed flow. Also the heat transfer is more for nanofluids compared to DI water.

  5. Beyond the standard two-film theory: Computational fluid dynamics simulations for carbon dioxide capture in a wetted wall column

    DOE PAGES

    Wang, Chao; Xu, Zhijie; Lai, Canhai; ...

    2018-03-27

    The standard two-film theory (STFT) is a diffusion-based mechanism that can be used to describe gas mass transfer across liquid film. Fundamental assumptions of the STFT impose serious limitations on its ability to predict mass transfer coefficients. To better understand gas absorption across liquid film in practical situations, a multiphase computational fluid dynamics (CFD) model fully equipped with mass transport and chemistry capabilities has been developed for solvent-based carbon dioxide (CO 2) capture to predict the CO 2 mass transfer coefficient in a wetted wall column. The hydrodynamics is modeled using a volume of fluid method, and the diffusive andmore » reactive mass transfer between the two phases is modeled by adopting a one-fluid formulation. We demonstrate that the proposed CFD model can naturally account for the influence of many important factors on the overall mass transfer that cannot be quantitatively explained by the STFT, such as the local variation in fluid velocities and properties, flow instabilities, and complex geometries. The CFD model also can predict the local mass transfer coefficient variation along the column height, which the STFT typically does not consider.« less

  6. Mass transfer study on the electrochemical removal of copper ions from synthetic effluents using reticulated vitreous carbon.

    PubMed

    Britto-Costa, Pedro H; Ruotolo, Luís Augusto M

    2013-01-01

    Porous electrodes have been successfully used for metal electrodeposition from diluted aqueous solution due to their high porosity and specific surface area, which lead to high mass transfer rates. This work studies the mass transfer of copper electrodeposition on reticulated vitreous carbon in a flow reactor without membrane. The flow configuration, otherwise the filter-press electrochemical reactors, was designed in order to minimize the pressure drop. The mass transfer coefficient was determined by voltammetric and galvanostatic electrodeposition. In the voltammetric experiments a Luggin capillary was used to measure the current-potential curves and to determine the limiting current (and, consequently, the mass transfer coefficient). In the galvanostatic experiments the concentration-time curves were obtained and considering a limiting current kinetics model, the mass transfer coefficient (k(m)) was determined for different flow velocities. The results showed that both methods give similar values of k(m), thus the voltammetric method can be recommended because it is faster and simpler. Finally, the reactor performance was compared with others from literature, and it was observed that the proposed reactor design has high Sherwood numbers similar to other reactor configurations using membranes and reticulated vitreous carbon electrodes.

  7. Experimental investigation of TiO2/water nanofluid laminar forced convective heat transfer through helical coiled tube

    NASA Astrophysics Data System (ADS)

    Kahani, M.; Zeinali Heris, S.; Mousavi, S. M.

    2014-05-01

    Coiled tubes and nanofludics are two significant techniques to enhance the heat transfer ability of thermal equipments. The forced convective heat transfer and the pressure drop of nanofluid inside straight tube and helical coiled one with a constant wall heat flux were studied experimentally. Distilled water was used as a host fluid and Nanofluids of aqueous TiO2 nanoparticles (50 nm) suspensions were prepared in various volume concentrations of 0.25-2 %. The heat transfer coefficient of nanofluids is obtained for different nanoparticle concentrations as well as various Reynolds numbers. The experiments covered a range of Reynolds number of 500-4,500. The results show the considerable enhancement of heat transfer rate, which is due to the nanoparticles present in the fluid. Heat transfer coefficient increases by increasing the volume concentration of nanoparticles as well as Reynolds number. Moreover, due to the curvature of the tube when fluid flows inside helical coiled tube instead of straight one, both convective heat transfer coefficient and the pressure drop of fluid grow considerably. Also, the thermal performance factors for tested nanofluids are greater than unity and the maximum thermal performance factor of 3.72 is found with the use of 2.0 % volume concentration of nanofluid at Reynolds number of 1,750.

  8. Shift in Mass Transfer of Wastewater Contaminants from Microplastics in the Presence of Dissolved Substances.

    PubMed

    Seidensticker, Sven; Zarfl, Christiane; Cirpka, Olaf A; Fellenberg, Greta; Grathwohl, Peter

    2017-11-07

    In aqueous environments, hydrophobic organic contaminants are often associated with particles. Besides natural particles, microplastics have raised public concern. The release of pollutants from such particles depends on mass transfer, either in an aqueous boundary layer or by intraparticle diffusion. Which of these mechanisms controls the mass-transfer kinetics depends on partition coefficients, particle size, boundary conditions, and time. We have developed a semianalytical model accounting for both processes and performed batch experiments on the desorption kinetics of typical wastewater pollutants (phenanthrene, tonalide, and benzophenone) at different dissolved-organic-matter concentrations, which change the overall partitioning between microplastics and water. Initially, mass transfer is externally dominated, while finally, intraparticle diffusion controls release kinetics. Under boundary conditions typical for batch experiments (finite bath), desorption accelerates with increasing partition coefficients for intraparticle diffusion, while it becomes independent of partition coefficients if film diffusion prevails. On the contrary, under field conditions (infinite bath), the pollutant release controlled by intraparticle diffusion is not affected by partitioning of the compound while external mass transfer slows down with increasing sorption. Our results clearly demonstrate that sorption/desorption time scales observed in batch experiments may not be transferred to field conditions without an appropriate model accounting for both the mass-transfer mechanisms and the specific boundary conditions at hand.

  9. Effect of operating temperature on styrene mass transfer characteristics in a biotrickling filter.

    PubMed

    Parnian, Parham; Zamir, Seyed Morteza; Shojaosadati, Seyed Abbas

    2017-05-01

    To study the effect of operating temperature on styrene mass transfer from gas to liquid phase in biotrickling filters (BTFs), overall mass transfer coefficient (K L a) was calculated through fitting test data to a general mass balance model under abiotic conditions. Styrene was used as the volatile organic compound and the BTF was packed with a mixture of pall rings and pumice. Operating temperature was set at 30°C and 50°C for mesophilic and thermophilic conditions, respectively. K L a values increased from 54 to 70 h -1 at 30°C and from 60 to 90 h -1 at 50°C, respectively, depending on the countercurrent gas to liquid flow ratio that varied in the range of 7.5-32. Evaluation of styrene mass transfer capacity (MTC) showed that liquid-phase mass transfer resistance decreased as the flow ratio increased at constant temperature. MTC also decreased with an increase in operating temperature. Both gas-liquid partition coefficient and K L a increased with increasing temperature; however the effect on gas-liquid partition coefficient was more significant and served to increase mass transfer limitations. Thermophilic biofiltration on the one hand increases mass transfer limitations, but on the other hand may enhance the biodegradation rate in favor of enhancing BTFs' performance.

  10. Experimental investigation of heat transfer characteristics of guar-based polymer solutions and gels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azouz, I.; Vinod, P.S.; Shah, S.N.

    1996-12-31

    An experimental investigation of the heat transfer characteristics of hydraulic fracturing fluids was conducted at the Fracturing Fluid Characterization Facility (FFCF) of the University of Oklahoma. The facility is equipped with a high pressure fracture simulator, coiled tubing fluid pre-conditioning system, and a full-scale, counter-current, double pipe heat exchanger. The fluids investigated include non-crosslinked and borate-crosslinked guar gum and hydroxypropyl guar (HPG). Results were also obtained for water and were used as a basis for comparison. The effects of flow rate, operating temperature, pH, and various levels of shear pre-conditioning, on the heat transfer behavior of the test fluids weremore » investigated. Results show a significant difference between the heat transfer coefficient of the pure solvent (water) and those of the polymer solutions tested. While all polymer solutions tested exhibited lower heat transfer coefficients than that of the pure solvent, crosslinking appears to enhance the heat transfer characteristics of the polymer fluids. It was also observed that shear preconditioning does not seem to have a significant effect on the heat transfer coefficient of the crosslinked gels. These findings are of great interest to the industry, especially to the petroleum industry where these fluids are commonly used during hydraulic fracturing of hydrocarbon reservoirs.« less

  11. Experimental study of heat transfer enhancement due to the surface vibrations in a flexible double pipe heat exchanger

    NASA Astrophysics Data System (ADS)

    Hosseinian, A.; Meghdadi Isfahani, A. H.

    2018-04-01

    In this study, the heat transfer enhancement due to the surface vibration for a double pipe heat exchanger, made of PVDF, is investigated. In order to create forced vibrations (3-9 m/s2, 100 Hz) on the outer surface of the heat exchanger electro-dynamic vibrators are used. Experiments were performed at inner Reynolds numbers ranging from 2533 to 9960. The effects of volume flow rate and temperature on heat transfer performance are evaluated. Results demonstrated that heat transfer coefficient increases by increasing vibration level and mass flow rate. The most increase in heat transfer coefficient is 97% which is obtained for the highest vibration level (9 m/s2) in the experiment range.

  12. Turbine heat transfer

    NASA Technical Reports Server (NTRS)

    Rohde, J. E.

    1982-01-01

    Objectives and approaches to research in turbine heat transfer are discussed. Generally, improvements in the method of determining the hot gas flow through the turbine passage is one area of concern, as is the cooling air flow inside the airfoil, and the methods of predicting the heat transfer rates on the hot gas side and on the coolant side of the airfoil. More specific areas of research are: (1) local hot gas recovery temperatures along the airfoil surfaces; (2) local airfoil wall temperature; (3) local hot gas side heat transfer coefficients on the airfoil surfaces; (4) local coolant side heat transfer coefficients inside the airfoils; (5) local hot gas flow velocities and secondary flows at real engine conditions; and (6) local delta strain range of the airfoil walls.

  13. Thermal analysis of turbulent flow of a supercritical fluid

    NASA Technical Reports Server (NTRS)

    Yamane, E.

    1979-01-01

    The influence of the large variation of thermodynamics and transport properties near the pseudocritical temperature on the heat transfer coefficient of supercritical fluid in turbulent flow was studied. The formation of the characteristics peak in the heat transfer coefficient vs. bulk temperature curve is described, and the necessity of the fluid element at pseudocritical temperature located in the buffer layer is discussed.

  14. Controlling the Internal Heat Transfer Coefficient by the Characteristics of External Flows

    NASA Astrophysics Data System (ADS)

    Zhuromskii, V. M.

    2018-01-01

    The engineering-physical fundamentals of substance synthesis in a boiling apparatus are presented. We have modeled a system of automatic stabilization of the maximum internal heat transfer coefficient in such an apparatus by the characteristics of external flows on the basis of adaptive seeking algorithms. The results of operation of the system in the shop are presented.

  15. Determination of drying kinetics and convective heat transfer coefficients of ginger slices

    NASA Astrophysics Data System (ADS)

    Akpinar, Ebru Kavak; Toraman, Seda

    2016-10-01

    In the present work, the effects of some parametric values on convective heat transfer coefficients and the thin layer drying process of ginger slices were investigated. Drying was done in the laboratory by using cyclone type convective dryer. The drying air temperature was varied as 40, 50, 60 and 70 °C and the air velocity is 0.8, 1.5 and 3 m/s. All drying experiments had only falling rate period. The drying data were fitted to the twelve mathematical models and performance of these models was investigated by comparing the determination of coefficient ( R 2), reduced Chi-square ( χ 2) and root mean square error between the observed and predicted moisture ratios. The effective moisture diffusivity and activation energy were calculated using an infinite series solution of Fick's diffusion equation. The average effective moisture diffusivity values and activation energy values varied from 2.807 × 10-10 to 6.977 × 10-10 m2/s and 19.313-22.722 kJ/mol over the drying air temperature and velocity range, respectively. Experimental data was used to evaluate the values of constants in Nusselt number expression by using linear regression analysis and consequently, convective heat transfer coefficients were determined in forced convection mode. Convective heat transfer coefficient of ginger slices showed changes in ranges 0.33-2.11 W/m2 °C.

  16. In-flight Compressible Turbulent Boundary Layer Measurements on a Hollow Cylinder at a Mach Number of 3.0

    NASA Technical Reports Server (NTRS)

    Quinn, R. D.; Gong, L.

    1978-01-01

    Skin temperatures, shearing forces, surface static pressures, and boundary layer pitot pressures and total temperatures were measured on a hollow cylinder 3.04 meters long and 0.437 meter in diameter mounted beneath the fuselage of the YF-12A airplane. The data were obtained at a nominal free stream Mach number of 3.0 and at wall-to-recovery temperature ratios of 0.66 to 0.91. The free stream Reynolds number had a minimal value of 4.2 million per meter. Heat transfer coefficients and skin friction coefficients were derived from skin temperature time histories and shear force measurements, respectively. Boundary layer velocity profiles were derived from pitot pressure measurements, and a Reynolds analogy factor of 1.11 was obtained from the measured heat transfer and skin friction data. The skin friction coefficients predicted by the theory of van Driest were in excellent agreement with the measurements. Theoretical heat transfer coefficients, in the form of Stanton numbers calculated by using a modified Reynolds analogy between skin friction and heat transfer, were compared with measured values. The measured velocity profiles were compared to Coles' incompressible law-of-the-wall profile.

  17. Experimental investigation of heat transfer coefficient of mini-channel PCHE (printed circuit heat exchanger)

    NASA Astrophysics Data System (ADS)

    Kwon, Dohoon; Jin, Lingxue; Jung, WooSeok; Jeong, Sangkwon

    2018-06-01

    Heat transfer coefficient of a mini-channel printed circuit heat exchanger (PCHE) with counter-flow configuration is investigated. The PCHE used in the experiments is two layered (10 channels per layer) and has the hydraulic diameter of 1.83 mm. Experiments are conducted under various cryogenic heat transfer conditions: single-phase, boiling and condensation heat transfer. Heat transfer coefficients of each experiments are presented and compared with established correlations. In the case of the single-phase experiment, empiricial correlation of modified Dittus-Boelter correlation was proposed, which predicts the experimental results with 5% error at Reynolds number range from 8500 to 17,000. In the case of the boiling experiment, film boiling phenomenon occurred dominantly due to large temperature difference between the hot side and the cold side fluids. Empirical correlation is proposed which predicts experimental results with 20% error at Reynolds number range from 2100 to 2500. In the case of the condensation experiment, empirical correlation of modified Akers correlation was proposed, which predicts experimental results with 10% error at Reynolds number range from 3100 to 6200.

  18. The heat transfer coefficient determination with the use of the Beck-Trefftz method in flow boiling in a minichannel

    NASA Astrophysics Data System (ADS)

    Strąk, Kinga; Maciejewska, Beata; Piasecka, Magdalena

    2018-06-01

    In this paper, the solution of the two-dimensional inverse heat transfer problem with the use of the Beck method coupled with the Trefftz method is proposed. This method was applied for solving an inverse heat conduction problem. The aim of the calculation was to determine the boiling heat transfer coefficient on the basis of temperature measurements taken by infrared thermography. The experimental data of flow boiling heat transfer in a single vertical minichannel of 1.7 mm depth, heated asymmetrically, were used in calculations. The heating element for two refrigerants (FC-72 and HFE-7100, 3M) flowing in the minichannel was the plate enhanced on the side contacting with the fluid. The analysis of the results was performed on the basis of experimental series obtained for the same heat flux and two different mass flow velocities. The results were presented as infrared thermographs, heated wall temperature and heat transfer coefficient as a function of the distance from the minichannel inlet. The results was discussed for the subcooled and saturated boiling regions separately.

  19. Implementation of one and three dimensional models for heat transfer coeffcient identification over the plate cooled by the circular water jets

    NASA Astrophysics Data System (ADS)

    Malinowski, Zbigniew; Cebo-Rudnicka, Agnieszka; Hadała, Beata; Szajding, Artur; Telejko, Tadeusz

    2017-10-01

    A cooling rate affects the mechanical properties of steel which strongly depend on microstructure evolution processes. The heat transfer boundary condition for the numerical simulation of steel cooling by water jets can be determined from the local one dimensional or from the three dimensional inverse solutions in space and time. In the present study the inconel plate has been heated to about 900 °C and then cooled by six circular water jets. The plate temperature has been measured by 30 thermocouples. The heat transfer coefficient and the heat flux distributions at the plate surface have been determined in time and space. The one dimensional solutions have given a local error to the heat transfer coefficient of about 35%. The three dimensional inverse solution has allowed reducing the local error to about 20%. The uncertainty test has confirmed that a better approximation of the heat transfer coefficient distribution over the cooled surface can be obtained even for limited number of thermocouples. In such a case it was necessary to constrain the inverse solution with the interpolated temperature sensors.

  20. Experimental Study of Heat Transfer Performance of Polysilicon Slurry Drying Process

    NASA Astrophysics Data System (ADS)

    Wang, Xiaojing; Ma, Dongyun; Liu, Yaqian; Wang, Zhimin; Yan, Yangyang; Li, Yuankui

    2016-12-01

    In recent years, the growth of the solar energy photovoltaic industry has greatly promoted the development of polysilicon. However, there has been little research into the slurry by-products of polysilicon production. In this paper the thermal performance of polysilicon slurry was studied in an industrial drying process with a twin-screw horizontal intermittent dryer. By dividing the drying process into several subunits, the parameters of each unit could be regarded as constant in that period. The time-dependent changes in parameters including temperature, specific heat and evaporation enthalpy were plotted. An equation for the change in the heat transfer coefficient over time was calculated based on heat transfer equations. The concept of a distribution coefficient was introduced to reflect the influence of stirring on the heat transfer area. The distribution coefficient ranged from 1.2 to 1.7 and was obtained with the fluid simulation software FLUENT, which simplified the calculation of heat transfer area during the drying process. These experimental data can be used to guide the study of polysilicon slurry drying and optimize the design of dryers for industrial processes.

  1. Heat-Transfer and Pressure Measurements on a Flat-Face Cylinder at a Mach Number Range of 2.49 to 4.44

    NASA Technical Reports Server (NTRS)

    Burbank, Paige B.; Stallings, Robert L., Jr.

    1959-01-01

    Heat-transfer coefficients and pressure distributions were obtained on a 4-inch-diameter flat-face cylinder in the Langley Unitary Plan wind tunnel. The measured stagnation heat-transfer coefficient agrees well with 55 percent of the theoretical value predicted by the modified Sibulkin method for a hemisphere. Pressure measurements indicated the dimensionless velocity gradient parameter r du\\ a(sub t) dx, where x=0 at the stagnation point was approximately 0.3 and invariant throughout the Mach number range from 2.49 to 4.44 and the Reynolds number range from 0.77 x 10(exp 6) to 1.46 x 10(exp 6). The heat-transfer coefficients on the cylindrical afterbody could be predicted with reasonable accuracy by flat-plate theory at an angle of attack of 0 deg. At angles of attack the cylindrical afterbody stagnation-line heat transfer could be computed from swept-cylinder theory for large distances back of the nose when the Reynolds number is based on the distance from the flow reattachment points.

  2. Experimental investigate of heat transfer for graphene/water nanofluid in micro heat exchanger

    NASA Astrophysics Data System (ADS)

    Abd Elhafez, S. E.; Abo-Zahhad, E. M.; El-Shazly, A. H.; El-Kady, M. F.

    2017-02-01

    In this investigation, the heat transfer characteristics of graphene nano platelets (GNPs)/water nanofluid were studied in a micro heat exchanger (MHE). The micro heat exchanger performance was also examined. The test setup was worked out in the laminar regime with Reynold numbers varying between 100 and 400GNPs/water nanofluid was prepared three different concentrations (0.025 wt. %, 0.05 wt. % and 0.1 wt. %) using ultrasonic wave. The influence of mass flow rate, inlet temperatures and weight fraction on the overall heat transfer coefficient (U) and logarithmic mean temperature (LMTD) were examined. The results showed considerable enhancement on the overall heat transfer coefficient of graphene/water nanofluid and the MHE effectiveness. A maximum enhancement on overall heat transfer coefficient was reached to 150% at Re=100 by 0.1wt% nanofluid. The effectiveness of micro heat exchanger was enhanced by increase weight fraction of graphene nanoparticle. Moreover, the experimental results showed that 0.1 wt. % GNPs/water nanofluid, flowing through MHE, has had high pressure drop, and pumping power, when it has been compared with 0.5 wt. % and 0.025 wt.%.

  3. Determination of the mass transfer limiting step of dye adsorption onto commercial adsorbent by using mathematical models.

    PubMed

    Marin, Pricila; Borba, Carlos Eduardo; Módenes, Aparecido Nivaldo; Espinoza-Quiñones, Fernando R; de Oliveira, Silvia Priscila Dias; Kroumov, Alexander Dimitrov

    2014-01-01

    Reactive blue 5G dye removal in a fixed-bed column packed with Dowex Optipore SD-2 adsorbent was modelled. Three mathematical models were tested in order to determine the limiting step of the mass transfer of the dye adsorption process onto the adsorbent. The mass transfer resistance was considered to be a criterion for the determination of the difference between models. The models contained information about the external, internal, or surface adsorption limiting step. In the model development procedure, two hypotheses were applied to describe the internal mass transfer resistance. First, the mass transfer coefficient constant was considered. Second, the mass transfer coefficient was considered as a function of the dye concentration in the adsorbent. The experimental breakthrough curves were obtained for different particle diameters of the adsorbent, flow rates, and feed dye concentrations in order to evaluate the predictive power of the models. The values of the mass transfer parameters of the mathematical models were estimated by using the downhill simplex optimization method. The results showed that the model that considered internal resistance with a variable mass transfer coefficient was more flexible than the other ones and this model described the dynamics of the adsorption process of the dye in the fixed-bed column better. Hence, this model can be used for optimization and column design purposes for the investigated systems and similar ones.

  4. Intensive Group Learning and On-Site Services to Improve Sexual and Reproductive Health Among Young Adults in Liberia: A Randomized Evaluation of HealthyActions.

    PubMed

    Firestone, Rebecca; Moorsmith, Reid; James, Simon; Urey, Marilyn; Greifinger, Rena; Lloyd, Danielle; Hartenberger-Toby, Lisa; Gausman, Jewel; Sanoe, Musa

    2016-09-28

    Young Liberians, particularly undereducated young adults, face substantial sexual and reproductive health (SRH) challenges, with low uptake of contraceptive methods, high rates of unintended pregnancy, and low levels of knowledge about HIV status. The purpose of this study was to assess the impact of a 6-day intensive group learning intervention combined with on-site SRH services (called HealthyActions) among out-of-school young adults, implemented through an existing alternative education program, on uptake of contraception and HIV testing and counseling (HTC). The intervention was implemented among young women and men ages 15-35 who were enrolled in alternative basic education learning sites in 5 counties of Liberia. We conducted a randomized evaluation to assess program impact. Baseline data were collected in January-March 2014, and endline data in June-July 2014. Key outcomes of condom use, contraceptive use, and HTC were estimated with difference-in-difference models using fixed effects. All analyses were conducted in Stata 13. We assessed outcomes for 1,157 learners at baseline and 1,052 learners at endline, across 29 treatment and 26 control sites. After adjusting for potential confounders, learners in the HealthyActions intervention group were 12% less likely to report never using a condom with a regular partner over the last month compared with the control group (P = .02). Female learners who received HealthyActions were 13% more likely to use any form of modern contraception compared with learners in control sites (P<.001), with the greatest increase in the use of contraceptive implants. Learners in HealthyActions sites were 45% more likely to have received HTC (P<.001). Providing intensive group learning in a supportive environment coupled with on-site health services improved SRH outcomes among participating learners. The focus of HealthyActions on participatory learning for low-literacy populations presents an adaptable solution for health programming across Liberia and the region. © Firestone et al.

  5. BTEX biodegradation by bacteria from effluents of petroleum refinery.

    PubMed

    Mazzeo, Dânia Elisa Christofoletti; Levy, Carlos Emílio; de Angelis, Dejanira de Franceschi; Marin-Morales, Maria Aparecida

    2010-09-15

    Groundwater contamination with benzene, toluene, ethylbenzene and xylene (BTEX) has been increasing, thus requiring an urgent development of methodologies that are able to remove or minimize the damages these compounds can cause to the environment. The biodegradation process using microorganisms has been regarded as an efficient technology to treat places contaminated with hydrocarbons, since they are able to biotransform and/or biodegrade target pollutants. To prove the efficiency of this process, besides chemical analysis, the use of biological assessments has been indicated. This work identified and selected BTEX-biodegrading microorganisms present in effluents from petroleum refinery, and evaluated the efficiency of microorganism biodegradation process for reducing genotoxic and mutagenic BTEX damage through two test-systems: Allium cepa and hepatoma tissue culture (HTC) cells. Five different non-biodegraded BTEX concentrations were evaluated in relation to biodegraded concentrations. The biodegradation process was performed in a BOD Trak Apparatus (HACH) for 20 days, using microorganisms pre-selected through enrichment. Although the biodegradation usually occurs by a consortium of different microorganisms, the consortium in this study was composed exclusively of five bacteria species and the bacteria Pseudomonas putida was held responsible for the BTEX biodegradation. The chemical analyses showed that BTEX was reduced in the biodegraded concentrations. The results obtained with genotoxicity assays, carried out with both A. cepa and HTC cells, showed that the biodegradation process was able to decrease the genotoxic damages of BTEX. By mutagenic tests, we observed a decrease in damage only to the A. cepa organism. Although no decrease in mutagenicity was observed for HTC cells, no increase of this effect after the biodegradation process was observed either. The application of pre-selected bacteria in biodegradation processes can represent a reliable and effective tool in the treatment of water contaminated with BTEX mixture. Therefore, the raw petroleum refinery effluent might be a source of hydrocarbon-biodegrading microorganisms. Copyright 2010 Elsevier B.V. All rights reserved.

  6. Assessing Hepatitis C Burden and Treatment Effectiveness through the British Columbia Hepatitis Testers Cohort (BC-HTC): Design and Characteristics of Linked and Unlinked Participants

    PubMed Central

    Janjua, Naveed Zafar; Kuo, Margot; Chong, Mei; Yu, Amanda; Alvarez, Maria; Cook, Darrel; Armour, Rosemary; Aiken, Ciaran; Li, Karen; Mussavi Rizi, Seyed Ali; Woods, Ryan; Godfrey, David; Wong, Jason; Gilbert, Mark; Tyndall, Mark W.; Krajden, Mel

    2016-01-01

    Background The British Columbia (BC) Hepatitis Testers Cohort (BC-HTC) was established to assess and monitor hepatitis C (HCV) epidemiology, cost of illness and treatment effectiveness in BC, Canada. In this paper, we describe the cohort construction, data linkage process, linkage yields, and comparison of the characteristics of linked and unlinked individuals. Methods The BC-HTC includes all individuals tested for HCV and/or HIV or reported as a case of HCV, hepatitis B (HBV), HIV or active tuberculosis (TB) in BC linked with the provincial health insurance client roster, medical visits, hospitalizations, drug prescriptions, the cancer registry and mortality data using unique personal health numbers. The cohort includes data since inception (1990/1992) of each database until 2012/2013 with plans for annual updates. We computed linkage rates by year and compared the characteristics of linked and unlinked individuals. Results Of 2,656,323 unique individuals available in the laboratory and surveillance data, 1,427,917(54%) were included in the final linked cohort, including about 1.15 million tested for HCV and about 1.02 million tested for HIV. The linkage rate was 86% for HCV tests, 89% for HCV cases, 95% for active TB cases, 48% for HIV tests and 36% for HIV cases. Linkage rates increased from 40% for HCV negatives and 70% for HCV positives in 1992 to ~90% after 2005. Linkage rates were lower for males, younger age at testing, and those with unknown residence location. Linkage rates for HCV testers co-infected with HIV, HBV or TB were very high (90–100%). Conclusion Linkage rates increased over time related to improvements in completeness of identifiers in laboratory, surveillance, and registry databases. Linkage rates were higher for HCV than HIV testers, those testing positive, older individuals, and females. Data from the cohort provide essential information to support the development of prevention, care and treatment initiatives for those infected with HCV. PMID:26954020

  7. Improved accuracy in high-temperature conversion elemental analyzer δ18O measurements of nitrogen-rich organics.

    PubMed

    Hunsinger, Glendon B; Stern, Libby A

    2012-03-15

    The use of high-temperature conversion (HTC) reduction systems interfaced with isotope ratio mass spectrometers for δ(18)O measurements of nitrogen-containing organic materials is complicated by isobaric interference from (14)N(16)O(+). This ion is produced in the ion source when N(2) reacts with trace oxygen shifting the m/z 30 baseline prior to elution of CO. We compared adaptations to a typical HTC system (TC/EA) to determine the best method to measure the δ(18)O values of nitrogen-rich organic substrates including: (1) 0.6 and 1.5 m 5 Å molecular sieve GC columns; (2) reduction of N(2) peak via He dilution; and (3) diversion of N(2) to waste via an automated four-port valve. These methods were applied to caffeine (IAEA-600), glycine, 4-nitroacetanilide, pentaerythritol tetranitrate (PETN) and cyclotrimethylene trinitramine (RDX), as well as pure and sodium azide-doped benzoic acid (IAEA-601) and sucrose (IAEA-CH6). The efficiency of N(2) production in the HTC interface was highly variable among these compounds. Both the longer column and the dilutor improved, but did not eliminate, the adverse effects of nitrogen. The diversion of N(2) adequately addressed the nitrogen-induced problems as indicated by: (1) consistent m/z 30 background offset between reference and sample CO for both N-free and N-rich materials; (2) production of the highest δ(18)O values; and (3) high correlation between the increase in the δ(18)O values relative to the GC-only measurements and the N(2) peak area. Additional validation would require N-rich oxygen isotope standards for inter-laboratory comparisons. Further, more stringent methodology may improve the poor inter-laboratory δ(18)O reproducibility of IAEA-600. Published in 2012 by John Wiley & Sons, Ltd.

  8. Rigorous Performance Evaluation of Smartphone GNSS/IMU Sensors for ITS Applications

    PubMed Central

    Gikas, Vassilis; Perakis, Harris

    2016-01-01

    With the rapid growth in smartphone technologies and improvement in their navigation sensors, an increasing amount of location information is now available, opening the road to the provision of new Intelligent Transportation System (ITS) services. Current smartphone devices embody miniaturized Global Navigation Satellite System (GNSS), Inertial Measurement Unit (IMU) and other sensors capable of providing user position, velocity and attitude. However, it is hard to characterize their actual positioning and navigation performance capabilities due to the disparate sensor and software technologies adopted among manufacturers and the high influence of environmental conditions, and therefore, a unified certification process is missing. This paper presents the analysis results obtained from the assessment of two modern smartphones regarding their positioning accuracy (i.e., precision and trueness) capabilities (i.e., potential and limitations) based on a practical but rigorous methodological approach. Our investigation relies on the results of several vehicle tracking (i.e., cruising and maneuvering) tests realized through comparing smartphone obtained trajectories and kinematic parameters to those derived using a high-end GNSS/IMU system and advanced filtering techniques. Performance testing is undertaken for the HTC One S (Android) and iPhone 5s (iOS). Our findings indicate that the deviation of the smartphone locations from ground truth (trueness) deteriorates by a factor of two in obscured environments compared to those derived in open sky conditions. Moreover, it appears that iPhone 5s produces relatively smaller and less dispersed error values compared to those computed for HTC One S. Also, the navigation solution of the HTC One S appears to adapt faster to changes in environmental conditions, suggesting a somewhat different data filtering approach for the iPhone 5s. Testing the accuracy of the accelerometer and gyroscope sensors for a number of maneuvering (speeding, turning, etc.,) events reveals high consistency between smartphones, whereas the small deviations from ground truth verify their high potential even for critical ITS safety applications. PMID:27527187

  9. Rigorous Performance Evaluation of Smartphone GNSS/IMU Sensors for ITS Applications.

    PubMed

    Gikas, Vassilis; Perakis, Harris

    2016-08-05

    With the rapid growth in smartphone technologies and improvement in their navigation sensors, an increasing amount of location information is now available, opening the road to the provision of new Intelligent Transportation System (ITS) services. Current smartphone devices embody miniaturized Global Navigation Satellite System (GNSS), Inertial Measurement Unit (IMU) and other sensors capable of providing user position, velocity and attitude. However, it is hard to characterize their actual positioning and navigation performance capabilities due to the disparate sensor and software technologies adopted among manufacturers and the high influence of environmental conditions, and therefore, a unified certification process is missing. This paper presents the analysis results obtained from the assessment of two modern smartphones regarding their positioning accuracy (i.e., precision and trueness) capabilities (i.e., potential and limitations) based on a practical but rigorous methodological approach. Our investigation relies on the results of several vehicle tracking (i.e., cruising and maneuvering) tests realized through comparing smartphone obtained trajectories and kinematic parameters to those derived using a high-end GNSS/IMU system and advanced filtering techniques. Performance testing is undertaken for the HTC One S (Android) and iPhone 5s (iOS). Our findings indicate that the deviation of the smartphone locations from ground truth (trueness) deteriorates by a factor of two in obscured environments compared to those derived in open sky conditions. Moreover, it appears that iPhone 5s produces relatively smaller and less dispersed error values compared to those computed for HTC One S. Also, the navigation solution of the HTC One S appears to adapt faster to changes in environmental conditions, suggesting a somewhat different data filtering approach for the iPhone 5s. Testing the accuracy of the accelerometer and gyroscope sensors for a number of maneuvering (speeding, turning, etc.,) events reveals high consistency between smartphones, whereas the small deviations from ground truth verify their high potential even for critical ITS safety applications.

  10. Chemistry of solutions from the 13°N East Pacific Rise hydrothermal site

    NASA Astrophysics Data System (ADS)

    Michard, G.; Albarède, F.; Michard, A.; Minster, J.-F.; Charlou, J.-L.; Tan, N.

    1984-03-01

    Ten samples were recovered by the submersible "Cyana" submersible from two groups of hydrothermal vents located 2600 m deep along the East Pacific Rise at 13°N. The maximum measured temperature was 317°C and minimum pH 3.8. A systematic determination of major and trace elements has been carried out and mixing lines between a high-temperature component (HTC) and seawater are observed. The water chemistry of the HTC slightly differs for several elements at the two sites. This HTC is deprived of SO 4 and Mg and is greatly enriched in most other species. Maximum concentrations are (in units per kg): Cl = 0.72mol; Br = 1.1mmol; Na = 0.55mol; K = 29mmol; Rb = 14 μmol; Ca = 52mmol; Sr = 170 μmol; Mn = 750 μmol; Fe = 1mmol; Al = 15 μmol; Si = 21mmol. For many elements, the magnitude of the anomaly relative to seawater does not compare with the results obtained from the Galapagos or East Pacific Rise 21°N. The enrichment of cations relative to seawater is likely related to the huge Cl excess through charge balance. The Br/Cl ratio is close to that for seawater. However, it is not clear whether the Cl excess is due to gas release or basalt hydration (formation of amphibole chlorite or epidote). P-T dependence of SiO 2 solubility suggests that water-rock interaction last occurred at a depth in excess of 1 km below the sea floor. A mixing line of 87Sr/ 86Sr vs. Mg/Sr demonstrates that the HTCs have a nearly identical 87Sr/ 86Sr ratio of 0.7041 for both sites. A water/rock ratio of about 5 is inferred, which differs from the 1.5 value obtained at 21°N.

  11. Retention in care and reasons for discontinuation of lifelong antiretroviral therapy in a cohort of Cameroonian pregnant and breastfeeding HIV-positive women initiating 'Option B+' in the South West Region.

    PubMed

    Atanga, Pascal N; Ndetan, Harrison T; Achidi, Eric A; Meriki, Henry D; Hoelscher, Michael; Kroidl, Arne

    2017-02-01

    To assess linkage and retention in care along the PMTCT cascade in HIV-positive pregnant and breastfeeding women initiating Option B+ in Cameroon. We prospectively determined uptake of HIV testing and counselling (HTC), uptake of ART and retention in care after Option B+ initiation between October 2013 and December 2014 in pregnant and breastfeeding women from five sites within the Kumba Health District. Retention in care was assessed over at least 12 months follow-up and estimated by Kaplan-Meier analysis. During follow-up, tracing outcomes and reasons for discontinuing treatment were documented. The uptake of HTC of 5813 women with unknown HIV status was 98.5%, 251 (4.4%) were newly diagnosed HIV positive, and ART uptake in women eligible to start Option B+ was 96.8%. We enrolled 268 women initiating lifelong ART in the follow-up. Overall, 65 (24.3%) discontinued treatment, either defined by loss to follow-up (44.6%) or actively stopped treatment (55.8%). Retention in care was 88.0% and 81.1% at 6 and 12 months, respectively. Discontinuation was significantly associated in multivariate analysis with small sites and high staff turnover [aOR 2.5 (95% CI 1.6, 3.9), P < 0.001]. Main reasons for stopping treatment were HIV status denial and stigma (52.8%), religious reasons (25.0%) and lack of transport fare (11.1%). We observed good uptake of HTC, ART and retention in care, which declined over time. Discontinuation of Option B+ was highest at small sites with a high staff turnover. Improved staffing, adequate task shifting and community interventions to track defaulters including reducing stigma and religious beliefs may improve Option B+ retention. © 2016 John Wiley & Sons Ltd.

  12. Novel Tool for Simultaneous Carbon and Nitrogen Stable Isotope Analyses in Aqueous Samples

    NASA Astrophysics Data System (ADS)

    Federherr, E.; Schmidt, T. C.; Cerli, C.; Kalbitz, K.; Kupka, H. J.; Lange, L.; Dunsbach, R.; Panetta, R. J.; Kasson, A.

    2014-12-01

    Investigation of transformation and transport processes of carbon and nitrogen in ecosystems plays an important role to understand and predict their dynamics and role in biogeochemistry. Consequently, suitable and accurate methods for concentration as well as stable isotopic composition analysis of carbon and nitrogen in waters and aqueous solutions play a significant role. Traditionally dissolved carbon and nitrogen stable isotope analysis (SIA) is performed using either offline sample preparation followed by elemental analysis isotope ratio mass spectrometry (EA/IRMS) or modified wet chemical oxidation based device coupled to IRMS. Recently we presented a high temperature combustion system (HTC), which significantly improves upon these methods for dissolved organic carbon (DOC) SIA. The analysis of δ15N of dissolved nitrogen still has large limitations. Its low concentration makes EA/IRMS laborious, time and sample consuming. Systems based on wet chemical oxidation-IRMS bare the risk of sensitivity loss as well as of fractionation due to incomplete mineralization. In addition, the high solubility of molecular nitrogen in water remains a technical challenge, as it requires additional separation steps to distinguish between physically dissolved nitrogen and bound nitrogen. Further development of our HTC system lead to the implementation of the δ15N determination which now coupled, into a novel total organic carbon (TOC) analyzing system, especially designed for SIA of both, carbon and nitrogen. Integrated, innovative purge and trap technique (peak focusing) for nitrogen with aluminosilicate adsorber and peltier element based cooling system, in combination with high injection volume (up to 3 mL) as well as favorable carrier gas flow significantly improves sensitivity. Down to 1ppm and less total nitrogen can be measured with precision of ≤ 0.5‰. To lower the background caused by physically dissolved nitrogen new, membrane-vacuum based, degasser was designed for online separation of physically dissolved nitrogen. This novel HTC system, "iso TOC cube", provides an innovative tool with large potential in investigation of biogeochemical carbon and nitrogen cycles.

  13. Assessing Hepatitis C Burden and Treatment Effectiveness through the British Columbia Hepatitis Testers Cohort (BC-HTC): Design and Characteristics of Linked and Unlinked Participants.

    PubMed

    Janjua, Naveed Zafar; Kuo, Margot; Chong, Mei; Yu, Amanda; Alvarez, Maria; Cook, Darrel; Armour, Rosemary; Aiken, Ciaran; Li, Karen; Mussavi Rizi, Seyed Ali; Woods, Ryan; Godfrey, David; Wong, Jason; Gilbert, Mark; Tyndall, Mark W; Krajden, Mel

    2016-01-01

    The British Columbia (BC) Hepatitis Testers Cohort (BC-HTC) was established to assess and monitor hepatitis C (HCV) epidemiology, cost of illness and treatment effectiveness in BC, Canada. In this paper, we describe the cohort construction, data linkage process, linkage yields, and comparison of the characteristics of linked and unlinked individuals. The BC-HTC includes all individuals tested for HCV and/or HIV or reported as a case of HCV, hepatitis B (HBV), HIV or active tuberculosis (TB) in BC linked with the provincial health insurance client roster, medical visits, hospitalizations, drug prescriptions, the cancer registry and mortality data using unique personal health numbers. The cohort includes data since inception (1990/1992) of each database until 2012/2013 with plans for annual updates. We computed linkage rates by year and compared the characteristics of linked and unlinked individuals. Of 2,656,323 unique individuals available in the laboratory and surveillance data, 1,427,917(54%) were included in the final linked cohort, including about 1.15 million tested for HCV and about 1.02 million tested for HIV. The linkage rate was 86% for HCV tests, 89% for HCV cases, 95% for active TB cases, 48% for HIV tests and 36% for HIV cases. Linkage rates increased from 40% for HCV negatives and 70% for HCV positives in 1992 to ~90% after 2005. Linkage rates were lower for males, younger age at testing, and those with unknown residence location. Linkage rates for HCV testers co-infected with HIV, HBV or TB were very high (90-100%). Linkage rates increased over time related to improvements in completeness of identifiers in laboratory, surveillance, and registry databases. Linkage rates were higher for HCV than HIV testers, those testing positive, older individuals, and females. Data from the cohort provide essential information to support the development of prevention, care and treatment initiatives for those infected with HCV.

  14. Passive air sampling theory for semivolatile organic compounds.

    PubMed

    Bartkow, Michael E; Booij, Kees; Kennedy, Karen E; Müller, Jochen F; Hawker, Darryl W

    2005-07-01

    The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K(SV)) when air-side resistance dominates and increase with K(SV) when sampler-side resistance dominates.

  15. Experimental and CFD-PBM Study of Oxygen Mass Transfer Coefficient in Different Impeller Configurations and Operational Conditions of a Two-Phase Partitioning Bioreactor.

    PubMed

    Moradkhani, Hamed; Izadkhah, Mir-Shahabeddin; Anarjan, Navideh

    2017-02-01

    In this work, gas dispersion in a two-phase partitioning bioreactor is analyzed by calculating volumetric oxygen mass transfer coefficient which is modeled using a commercial computational fluid dynamics (CFD), code FLUENT 6.2. Dispersed oxygen bubbles dynamics is based on standard "k-ε" Reynolds-averaged Navier-Stokes (RANS) model. This paper describes a three-dimensional CFD model coupled with population balance equations (PBE) in order to get more confirming results of experimental measurements. Values of k L a are obtained using dynamic gassing-out method. Using the CFD simulation, the volumetric mass transfer coefficient is calculated based on Higbie's penetration theory. Characteristics of mass transfer coefficient are investigated for five configurations of impeller and three different aeration flow rates. The pitched six blade type, due to the creation of downward flow direction, leads to higher dissolved oxygen (DO) concentrations, thereby, higher values of k L a compared with other impeller compositions. The magnitude of dissolved oxygen percentage in the aqueous phase has direct correlation with impeller speed and any increase of the aeration magnitude leads to faster saturation in shorter periods of time. Agitation speeds of 300 to 800 rpm are found to be the most effective rotational speeds for the mass transfer of oxygen in two-phase partitioning bioreactors (TPPB).

  16. Flow boiling with enhancement devices for cold plate coolant channel design

    NASA Technical Reports Server (NTRS)

    Boyd, Ronald D., Sr.; Smith, Alvin

    1990-01-01

    The use of flow boiling for thermal energy transport is intended to provide an alternative for accommodating higher heat fluxes in commercial space systems. The objectives are to: (1) examine the variations in both the mean and local (axial and circumferential) heat transfer coefficients for a circular coolant channel with either smooth walls, spiral fins, or both spiral fins and a twisted tape; (2) examine the effects of channel diameter and subcooling; and (3) develop an improved reduction analysis and/or suggest possible heat transfer correlation of the present data. Freon-11 is the working fluid. Two-dimensional (circumferential and axial) wall temperature distributions were measured for coolant channels with the above noted internal geometries. The flow regimes which are being studied are: (1) single phase; (2) subcooled flow boiling; and (3) stratified flow boiling. The inside diameter of all test sections is near 1.0 cm. Cicumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a mass velocity of 210 kg/sq m s, an exit pressure of 0.19 MPa (absolute), and an inlet subcooling of 20.8 C. Overall (averaged over the entire channel) heat transfer coefficients were compared for the above channel geometries. This comparison showed that the channel with large pitch spiral fins had higher heat transfer coefficients at all power levels.

  17. Numerical Simulation of Heat Transfer in Porous Metals for Cooling Applications

    NASA Astrophysics Data System (ADS)

    Gauna, Edgar Avalos; Zhao, Yuyuan

    2017-08-01

    Porous metals have low densities and novel physical, mechanical, thermal, electrical, and acoustic properties. Hence, they have attracted a large amount of interest over the last few decades. One of their applications is for thermal management in the electronics industry because of their fluid permeability and thermal conductivity. The heat transfer capability is achieved by the interaction between the internal channels within the porous metal and the coolant flowing through them. This paper studies the fluid flow and heat transfer in open-cell porous metals manufactured by space holder methods by numerical simulation using software ANSYS Fluent. A 3D geometric model of the porous structure was created based on the face-centered-cubic arrangement of spheres linked by cylinders. This model allows for different combinations of pore parameters including a wide range of porosity (50 to 80 pct), pore size (400 to 1000 µm), and metal particle size (10 to 75 µm). In this study, water was used as the coolant and copper was selected as the metal matrix. The flow rate was varied in the Darcian and Forchheimer's regimes. The permeability, form drag coefficient, and heat transfer coefficient were calculated under a range of conditions. The numerical results showed that permeability increased whereas the form drag coefficient decreased with porosity. Both permeability and form drag coefficient increased with pore size. Increasing flow rate and decreasing porosity led to better heat transfer performance.

  18. New biotite and muscovite isotopic reference materials, USGS57 and USGS58, for δ2H measurements–A replacement for NBS 30

    USGS Publications Warehouse

    Qi, Haiping; Coplen, Tyler B.; Gehre, Matthias; Vennemann, Torsten W.; Brand, Willi A.; Geilmann, Heike; Olack, Gerard; Bindeman, Ilya N.; Palandri, Jim; Huang, Li; Longstaffe, Fred J.

    2017-01-01

    The advent of continuous-flow isotope-ratio mass spectrometry (CF-IRMS) coupled with a high temperature conversion (HTC) system enabled faster, more cost effective, and more precise δ2H analysis of hydrogen-bearing solids. Accurate hydrogen isotopic analysis by on-line or off-line techniques requires appropriate isotopic reference materials (RMs). A strategy of two-point calibrations spanning δ2H range of the unknowns using two RMs is recommended. Unfortunately, the supply of the previously widely used isotopic RM, NBS 30 biotite, is exhausted. In addition, recent measurements have shown that the determination of δ2H values of NBS 30 biotite on the VSMOW-SLAP isotope-delta scale by on-line HTC systems with CF-IRMS may be unreliable because hydrogen in this biotite may not be converted quantitatively to molecular hydrogen. The δ2HVSMOW-SLAP values of NBS 30 biotite analyzed by on-line HTC systems can be as much as 21 mUr (or ‰) too positive compared to the accepted value of − 65.7 mUr, determined by only a few conventional off-line measurements. To ensure accurate and traceable on-line hydrogen isotope-ratio determinations in mineral samples, we here propose two isotopically homogeneous, hydrous mineral RMs with well-characterized isotope-ratio values, which are urgently needed. The U.S. Geological Survey (USGS) has prepared two such RMs, USGS57 biotite and USGS58 muscovite. The δ2H values were determined by both glassy carbon-based on-line conversion and chromium-based on-line conversion, and results were confirmed by off-line conversion. The quantitative conversion of hydrogen from the two RMs using the on-line HTC method was carefully evaluated in this study. The isotopic compositions of these new RMs with 1-σ uncertainties and mass fractions of hydrogen are:USGS57 (biotite)δ2HVSMOW-SLAP = − 91.5 ± 2.4 mUr (n = 24)Mass fraction hydrogen = 0.416 ± 0.002% (n = 4)Mass fraction water = 3.74 ± 0.02% (n = 4)USGS58 (muscovite)δ2HVSMOW-SLAP = − 28.4 ± 1.6 mUr (n = 24)Mass fraction hydrogen = 0.448 ± 0.002% (n = 4)Mass fraction water = 4.03 ± 0.02% (n = 4).These δ2HVSMOW-SLAP values encompass typical ranges for solid unknowns of crustal and mantle origin and are available to users for recommended two-point calibration.

  19. Some investigations on the enhancement of boiling heat transfer from planer surface embedded with continuous open tunnels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, A.K.; Das, P.K.; Saha, P.

    2010-11-15

    Boiling heat transfer from a flat surface can be enhanced if continuous open tunnel type structures are embedded in it. Further, improvement of boiling heat transfer from such surfaces has been tried by two separate avenues. At first, inclined tunnels are embedded over the solid surface and an effort is made to optimize the tunnel inclination for boiling heat transfer. Surfaces are manufactured in house with four different inclinations of the tunnels with or without a reentrant circular pocket at the end of the tunnel. Experiments conducted in the nucleate boiling regime showed that 45 deg inclination of the tunnelsmore » for both with and without base geometry provides the highest heat transfer coefficient. Next, active fluid rotation was imposed to enhance the heat transfer from tunnel type surfaces with and without the base geometry. Rotational speed imparted by mechanical stirrer was varied over a wide range. It was observed that fluid rotation enhances the heat transfer coefficient only up to a certain value of stirrer speed. Rotational speed values, beyond this limit, reduce the boiling heat transfer severely. A comparison shows that embedding continuous tunnel turns out to be a better option for the increase of heat transfer coefficient compared to the imposition of fluid rotation. But the behavior of inclined tunnels under the action of fluid rotation is yet to be established and can be treated as a future scope of the work. (author)« less

  20. Thermal analysis of insulated north-wall greenhouse with solar collector under passive mode

    NASA Astrophysics Data System (ADS)

    Chauhan, Prashant Singh; Kumar, Anil

    2018-04-01

    An insulated north wall greenhouse dryer has been fabricated and tested for no-load condition under passive mode. Testing has been conducted in two different cases. Case-I is considered for solar collector kept inside the dryer and Case-II is dryer without solar collector. Convective heat transfer coefficient and various heat transfer dimensionless numbers with have been calculated for thermal analysis. The maximum convective heat transfer coefficient is found 52.18 W/m2°C at 14 h during the first day for Case-I. The difference of the highest convective heat transfer coefficient of both cases was 8.34 W/m2°C. Net heat gain inside room curves are uniform and smooth for Case-I, which shows the steady heat generation process due to presence of solar collector inside the dryer. Above results depicts the effectiveness of solar collector and insulated north wall. The selection of suitable crop for drying can be done by analysing article's result.

  1. Experimental determination of convective heat transfer coefficients in the separated flow region of the Space Shuttle Solid Rocket Motor

    NASA Technical Reports Server (NTRS)

    Whitesides, R. Harold; Majumdar, Alok K.; Jenkins, Susan L.; Bacchus, David L.

    1990-01-01

    A series of cold flow heat transfer tests was conducted with a 7.5-percent scale model of the Space Shuttle Rocket Motor (SRM) to measure the heat transfer coefficients in the separated flow region around the nose of the submerged nozzle. Modifications were made to an existing 7.5 percent scale model of the internal geometry of the aft end of the SRM, including the gimballed nozzle in order to accomplish the measurements. The model nozzle nose was fitted with a stainless steel shell with numerous thermocouples welded to the backside of the thin wall. A transient 'thin skin' experimental technique was used to measure the local heat transfer coefficients. The effects of Reynolds number, nozzle gimbal angle, and model location were correlated with a Stanton number versus Reynolds number correlation which may be used to determine the convective heating rates for the full scale Space Shuttle Solid Rocket Motor nozzle.

  2. Micro/Nano-Scale Phase Change Systems for Thermal Management and Solar Energy Conversion Applications

    NASA Astrophysics Data System (ADS)

    Coso, Dusan

    The first part of the dissertation presents a study that implements micro and nano scale engineered surfaces for enhancement of evaporation and boiling phase change heat transfer in both capillary wick structures and pool boiling systems. Capillary wicking surfaces are integral components of heat pipes and vapor chamber thermal spreaders often used for thermal management of microelectronic devices. In addition, pool boiling systems can be encountered in immersion cooling systems which are becoming more commonly investigated for thermal management applications of microelectronic devices and even data centers. The latent heat associated with the change of state from liquid to vapor, and the small temperature differences required to drive this process yield great heat transfer characteristics. Additionally, since no external energy is required to drive the phase change process, these systems are great for portable devices and favorable for reduction of cost and energy consumption over alternate thermal management technologies. Most state of the art capillary wicks used in these devices are typically constructed from sintered copper media. These porous structures yield high surface areas of thin liquid film where evaporation occurs, thus promoting phase change heat transfer. However, thermal interfaces at particle point contacts formed during the sintering process and complex liquid/vapor flow within these wick structures yield high thermal and liquid flow resistances and limit the maximum heat flux they can dissipate. In capillary wicks the maximum heat flux is typically governed by the capillary or boiling limits and engineering surfaces that delay these limitations and yield structures with large surface areas of thin liquid film where phase change heat transfer is promoted is highly desired. In this study, biporous media consisting of microscale pin fins separated by microchannels are examined as candidate structures for the evaporator wick of a vapor chamber heat pipe. Smaller pores are used to generate high capillary suction, while larger microchannels are used to alleviate flow resistance. The heat transfer coefficient is found to depend on the area coverage of a liquid film with thickness on the order of a few microns near the meniscus of the triple phase contact line. We manipulate the area coverage and film thickness by varying the surface area-to-volume ratio through the use of microstructuring. In some samples, a transition from evaporative heat transfer to nucleate boiling is observed. While it is difficult to identify when the transition occurs, one can identify regimes where evaporation dominates over nucleate boiling and vice versa. Heat fluxes of 277.0 (+/- 9.7) W/cm2 can be dissipated by wicks with heaters of area 1 cm2, while heat fluxes up to 733.1 (+/- 103.4) W/cm2 can be dissipated by wicks with smaller heaters intended to simulate local hot-spots. In pool boiling systems that are encountered in immersion cooling applications, the heat transfer coefficient (HTC) is governed by the bubble nucleation site density and the agitation in the liquid/vapor flow these bubbles produce when they detach from the surface. The nucleation site density and release rate is usually determined by the surface morphology. Another important parameter in pool boiling systems is the maximum heat flux (CHF) that can safely be dissipated. In practice, this quantity is about two orders of magnitude smaller than limitations suggested by kinetic theory. For essentially infinite, smooth, well wetted surfaces, hydrodynamic instability theories capturing liquid/vapor interactions away from the heated surface have been successful in predicting CHF. On finite micro and nano structured surfaces where applying the hydrodynamic theory formulation is not easily justified, other effects may contribute to phase change heat transfer characteristics. Here, we also present a pool boiling study on biporous microstructured surfaces used in capillary wick experiments. Structures are manipulated by reduction of pore size to determine if increased capillary pressure can enhance rewetting from heater edges and delay CHF. A comparative study between the two experimental systems indicates that while the capillary limitation is significant in capillary wick experiments, for these well wetted microstructured surfaces used in pool boiling systems the hydrodynamic limitation defined based on heater size causes the occurrence of CHF. Other hierarchical nanowire surfaces containing periodic microscale cavities are investigated as well and are seen to yield a ˜2.4 fold increase in heat transfer coefficient characteristics while not compromising CHF compared to surfaces where cavities are not present. These studies indicate pathways for enhancement of heat transfer coefficient via implementing hierarchical structures, while no clear method in increasing CHF is determined for finite size surfaces of various morphologies. In the second part of this dissertation, solar energy storage is sought in 'phase change' of photochromic molecular systems: the storage of solar energy in the chemical bonds of photosensitive molecules (a photochemical reaction) and subsequent recovery of the energy in a back reaction in the form of heat, reversibly. These molecular systems are interesting alternatives to photovoltaic and solar thermal technologies which cannot satisfy the needs of load leveling, or for portable municipal heating applications. Typically made of organic compounds, these molecules have become known for rapid decomposition, short energy storage time scales and poor energy storing efficiencies. Thus, they have been abandoned as practical solar energy storage systems in the past several decades. On the other hand, organometallic molecular systems have not been extensively probed for these applications. Recent research has indicated that organometallic (fulvalene)diruthenium FvRu2 has demonstrated excellent energy storage characteristic and durability. Here, we report on a full cycle molecular solar thermal (MOST) microfluidic system based on a bis(1,1-dimethyltridecyl) substituted derivative of FvRu2 that allows for long term solar energy storage (110 J/g), and "on demand" energy release upon exposure to a catalyst. The microfluidic systems developed here are excellent for photoconversion characterization and scrutinizing potential catalysts and can be extended to studying many other molecular systems. The objective of the work presented here is to demonstrate that "on demand" solar energy storage and release in MOST systems is viable and motivate future research on other photochromic organometallic systems.

  3. Properties and heat transfer coefficients of four molten-salt high temperature heat transfer fluid candidates for concentrating solar power plants

    NASA Astrophysics Data System (ADS)

    Liu, T. L.; Liu, W. R.; Xu, X. H.

    2017-11-01

    Heat transfer fluid is one critical component for transferring and storing heat energy in concentrating solar power systems. Molten-salt mixtures can be used as high temperature heat transfer fluids because of their thermophysical properties. This paper studied the thermophysical properties of Li2CO3-Na2CO3-K2CO3 eutectic salt and three eutectic chloride salts NaCl-KCl-ZnCl2 with different compositions in the range of 450-600°C and 250-800°C, respectively. Properties including specific heat capacity, thermal conductivity, density and viscosity were determined based on imperial correlations and compared at different operating temperatures. The heat transfer coefficients of using different eutectic salts as heat transfer fluids were also calculated and compared in their operating temperature range. It is concluded that all the four eutectic salts can satisfy the requirements of a high-temperature heat transfer fluid.

  4. Coefficients of interphase distribution and Gibbs energy of the transfer of nicotinic acid from water into aqueous solutions of ethanol and dimethylsulfoxide

    NASA Astrophysics Data System (ADS)

    Grazhdan, K. V.; Gamov, G. A.; Dushina, S. V.; Sharnin, V. A.

    2012-11-01

    Coefficients of the interphase distribution of nicotinic acid are determined in aqueous solution systems of ethanol-hexane and DMSO-hexane at 25.0 ± 0.1°C. They are used to calculate the Gibbs energy of the transfer of nicotinic acid from water into aqueous solutions of ethanol and dimethylsulfoxide. The Gibbs energy values for the transfer of the molecular and zwitterionic forms of nicotinic acid are obtained by means of UV spectroscopy. The diametrically opposite effect of the composition of binary solvents on the transfer of the molecular and zwitterionic forms of nicotinic acid is noted.

  5. A note on adding viscoelasticity to earthquake simulators

    USGS Publications Warehouse

    Pollitz, Fred

    2017-01-01

    Here, I describe how time‐dependent quasi‐static stress transfer can be implemented in an earthquake simulator code that is used to generate long synthetic seismicity catalogs. Most existing seismicity simulators use precomputed static stress interaction coefficients to rapidly implement static stress transfer in fault networks with typically tens of thousands of fault patches. The extension to quasi‐static deformation, which accounts for viscoelasticity of Earth’s ductile lower crust and mantle, involves the precomputation of additional interaction coefficients that represent time‐dependent stress transfer among the model fault patches, combined with defining and evolving additional state variables that track this stress transfer. The new approach is illustrated with application to a California‐wide synthetic fault network.

  6. A surface renewal model for unsteady-state mass transfer using the generalized Danckwerts age distribution function.

    PubMed

    Horvath, Isabelle R; Chatterjee, Siddharth G

    2018-05-01

    The recently derived steady-state generalized Danckwerts age distribution is extended to unsteady-state conditions. For three different wind speeds used by researchers on air-water heat exchange on the Heidelberg Aeolotron, calculations reveal that the distribution has a sharp peak during the initial moments, but flattens out and acquires a bell-shaped character with process time, with the time taken to attain a steady-state profile being a strong and inverse function of wind speed. With increasing wind speed, the age distribution narrows significantly, its skewness decreases and its peak becomes larger. The mean eddy renewal time increases linearly with process time initially but approaches a final steady-state value asymptotically, which decreases dramatically with increased wind speed. Using the distribution to analyse the transient absorption of a gas into a large body of liquid, assuming negligible gas-side mass-transfer resistance, estimates are made of the gas-absorption and dissolved-gas transfer coefficients for oxygen absorption in water at 25°C for the three different wind speeds. Under unsteady-state conditions, these two coefficients show an inverse behaviour, indicating a heightened accumulation of dissolved gas in the surface elements, especially during the initial moments of absorption. However, the two mass-transfer coefficients start merging together as the steady state is approached. Theoretical predictions of the steady-state mass-transfer coefficient or transfer velocity are in fair agreement (average absolute error of prediction = 18.1%) with some experimental measurements of the same for the nitrous oxide-water system at 20°C that were made in the Heidelberg Aeolotron.

  7. Viscosity induced non-uniform flow in laminar flow heat exchangers

    NASA Astrophysics Data System (ADS)

    Putnam, G. R.; Rohsenow, W. M.

    1985-05-01

    Laminar flow heat exchangers which cool oil in noninterconnected parallel passages can experience nonuniform flows and a reduction in the effective heat exchanger coefficient in a range of Reynolds number which varies with tube length and diameter, tube wall temperature and fluid inlet temperature. The method of predicting the reduction in effective heat transfer coefficient and the range of Reynolds number over which these instabilities exist is presented for a particular oil, Mobil aviation oil 120. Included, also, is the prediction of the effect of radial viscosity variation on the constant property magnitudes of friction and heat transfer coefficient.

  8. Estimation of instantaneous heat transfer coefficients for a direct-injection stratified-charge rotary engine

    NASA Technical Reports Server (NTRS)

    Lee, C. M.; Addy, H. E.; Bond, T. H.; Chun, K. S.; Lu, C. Y.

    1987-01-01

    The main objective of this report was to derive equations to estimate heat transfer coefficients in both the combustion chamber and coolant pasage of a rotary engine. This was accomplished by making detailed temperature and pressure measurements in a direct-injection stratified-charge rotary engine under a range of conditions. For each sppecific measurement point, the local physical properties of the fluids were calculated. Then an empirical correlation of the coefficients was derived by using a multiple regression program. This correlation expresses the Nusselt number as a function of the Prandtl number and Reynolds number.

  9. Hydrothermal carbonization of autoclaved municipal solid waste pulp and anaerobically treated pulp digestate

    USDA-ARS?s Scientific Manuscript database

    In this study, the autoclaved organic fraction of municipal solid waste pulp (OFMSW) and the digestate from OFMSW pulp after anaerobic digestion (AD) were processed by hydrothermal carbonization (HTC) at 200, 250, and 300 °C for 30 min and 2 h. The focus of this work was to evaluate the potential fo...

  10. 76 FR 56760 - Granting of Request for Early Termination of the Waiting Period Under the Premerger Notification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-14

    ... Partners II, L.P.; OCM Principal Opportunities Fund III, L.P. 20111257 G Algonquin Power & Utilities Corp.; Atmos Energy Corporation; Algonquin Power & Utilities Corp. 08/26/2011 20111178 G Smith Family Voting...; Beats Electronics, LLC; HTC Corporation. 20111270 G Atlantic Power Corporation; Capital Power Income L.P...

  11. Contribution of heat transfer to turbine blades and vanes for high temperature industrial gas turbines. Part 2: Heat transfer on serpentine flow passage.

    PubMed

    Takeishi, K; Aoki, S

    2001-05-01

    The improvement of the heat transfer coefficient of the 1st row blades in high temperature industrial gas turbines is one of the most important issues to ensure reliable performance of these components and to attain high thermal efficiency of the facility. This paper deals with the contribution of heat transfer to increase the turbine inlet temperature of such gas turbines in order to attain efficient and environmentally benign engines. Following the experiments described in Part 1, a set of trials was conducted to clarify the influence of the blade's rotating motion on the heat transfer coefficient for internal serpentine flow passages with turbulence promoters. Test results are shown and discussed in this second part of the contribution.

  12. Boiling of multicomponent working fluids used in refrigeration and cryogenic systems

    NASA Astrophysics Data System (ADS)

    Mogorychny, V. I.; Dolzhikov, A. S.

    2017-11-01

    Working fluids based on mixtures are widely used in cryogenic and refrigeration engineering. One of the main elements of low-temperature units is a recuperative heat exchanger where the return flow cools the direct (cold regeneration is carrying out) resulting in continuous boiling and condensation of the multicomponent working fluid in the channels. The temperature difference between the inlet and outlet of the heat exchanger can be more than 100K, which leads to a strong change in thermophysical properties along its length. In addition, the fraction of the liquid and vapor phases in the flow varies very much, which affects the observed flow regimes in the heat exchanger channels. At the moment there are not so many experimental data and analytical correlations that would allow to estimate the heat transfer coefficient during the flow of a two-phase mixture flow at low temperatures. The work is devoted to the study of the boiling process of multicomponent working fluids used in refrigeration and cryogenic engineering. The description of the method of determination of heat transfer coefficient during boiling of mixtures in horizontal heated channel is given as well as the design of the experimental stand allowing to make such measurements. This stand is designed on the basis of a refrigeration unit operating on the Joule-Thomson throttle cycle and makes it possible to measure the heat transfer coefficient with a good accuracy. Also, the calculated values of the heat transfer coefficient, obtained with the use of various correlations, are compared with the existing experimental data. Knowing of the heat transfer coefficient will be very useful in the design of heat exchangers for low-temperature units operating on a mixture refrigerant.

  13. Effect of Substrate and Process Parameters on the Gas-Substrate Convective Heat Transfer Coefficient During Cold Spraying

    NASA Astrophysics Data System (ADS)

    Mahdavi, Amirhossein; McDonald, André

    2018-02-01

    The final quality of cold-sprayed coatings can be significantly influenced by gas-substrate heat exchange, due to the dependence of the deposition efficiency of the particles on the substrate temperature distribution. In this study, the effect of the air temperature and pressure, as process parameters, and surface roughness and thickness, as substrate parameters, on the convective heat transfer coefficient of the impinging air jet was investigated. A low-pressure cold spraying unit was used to generate a compressed air jet that impinged on a flat substrate. A comprehensive mathematical model was developed and coupled with experimental data to estimate the heat transfer coefficient and the surface temperature of the substrate. The effect of the air total temperature and pressure on the heat transfer coefficient was studied. It was found that increasing the total pressure would increase the Nusselt number of the impinging air jet, while total temperature of the air jet had negligible effect on the Nusslet number. It was further found that increasing the roughness of the substrate enhanced the heat exchange between the impinging air jet and the substrate. As a result, higher surface temperatures on the rough substrate were measured. The study of the effect of the substrate thickness on the heat transfer coefficient showed that the Nusselt number that was predicted by the model was independent of the thickness of the substrate. The surface temperature profile, however, decreased in increasing radial distances from the stagnation point of the impinging jet as the thickness of the substrate increased. The results of the current study were aimed to inform on the influence and effect of substrate and process parameters on the gas-substrate heat exchange and the surface temperature of the substrate on the final quality of cold-sprayed coatings.

  14. Priority design parameters of industrialized optical fiber sensors in civil engineering

    NASA Astrophysics Data System (ADS)

    Wang, Huaping; Jiang, Lizhong; Xiang, Ping

    2018-03-01

    Considering the mechanical effects and the different paths for transferring deformation, optical fiber sensors commonly used in civil engineering have been systematically classified. Based on the strain transfer theory, the relationship between the strain transfer coefficient and allowable testing error is established. The proposed relationship is regarded as the optimal control equation to obtain the optimal value of sensors that satisfy the requirement of measurement precision. Furthermore, specific optimization design methods and priority design parameters of the classified sensors are presented. This research indicates that (1) strain transfer theory-based optimization design method is much suitable for the sensor that depends on the interfacial shear stress to transfer the deformation; (2) the priority design parameters are bonded (sensing) length, interfacial bonded strength, elastic modulus and radius of protective layer and thickness of adhesive layer; (3) the optimization design of sensors with two anchor pieces at two ends is independent of strain transfer theory as the strain transfer coefficient can be conveniently calibrated by test, and this kind of sensors has no obvious priority design parameters. Improved calibration test is put forward to enhance the accuracy of the calibration coefficient of end-expanding sensors. By considering the practical state of sensors and the testing accuracy, comprehensive and systematic analyses on optical fiber sensors are provided from the perspective of mechanical actions, which could scientifically instruct the application design and calibration test of industrialized optical fiber sensors.

  15. Experimental Technique and Assessment for Measuring the Convective Heat Transfer Coefficient from Natural Ice Accretions

    NASA Technical Reports Server (NTRS)

    Masiulaniec, K. Cyril; Vanfossen, G. James, Jr.; Dewitt, Kenneth J.; Dukhan, Nihad

    1995-01-01

    A technique was developed to cast frozen ice shapes that had been grown on a metal surface. This technique was applied to a series of ice shapes that were grown in the NASA Lewis Icing Research Tunnel on flat plates. Nine flat plates, 18 inches square, were obtained from which aluminum castings were made that gave good ice shape characterizations. Test strips taken from these plates were outfitted with heat flux gages, such that when placed in a dry wind tunnel, can be used to experimentally map out the convective heat transfer coefficient in the direction of flow from the roughened surfaces. The effects on the heat transfer coefficient for both parallel and accelerating flow will be studied. The smooth plate model verification baseline data as well as one ice roughened test case are presented.

  16. Analysis and experimental study on the strain transfer mechanism of an embedded basalt fiber-encapsulated fiber Bragg grating sensor

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenglin; Wang, Yuan; Sun, Yangyang; Zhang, Qinghua; You, Zewei; Huang, Xiaodi

    2017-01-01

    The precision of the encapsulated fiber optic sensor embedded into a host suffers from the influences of encapsulating materials. Furthermore, an interface transfer effect of strain sensing exists. This study uses an embedded basalt fiber-encapsulated fiber Bragg grating (FBG) sensor as the research object to derive an expression in a multilayer interface strain transfer coefficient by considering the mechanical properties of the host material. The direct impact of the host material on the strain transfer at an embedded multipoint continuous FBG (i.e., multiple gratings written on a single optical fiber) monitoring strain sensor, which was self-developed and encapsulated with basalt fiber, is studied to present the strain transfer coefficients corresponding to the positions of various gratings. The strain transfer coefficients of the sensor are analyzed based on the experiments designed for this study. The error of the experimental results is ˜2 μɛ when the strain is at 60 μɛ and below. Moreover, the measured curves almost completely coincide with the theoretical curves. The changes in the internal strain field inside the embedded structure of the basalt fiber-encapsulated FBG strain sensor could be easily monitored. Hence, important references are provided to measure the internal stress strain of the sensor.

  17. Influence of relative air/water flow velocity on oxygen mass transfer in gravity sewers.

    PubMed

    Carrera, Lucie; Springer, Fanny; Lipeme-Kouyi, Gislain; Buffiere, Pierre

    2017-04-01

    Problems related to hydrogen sulfide may be serious for both network stakeholders and the public in terms of health, sustainability of the sewer structure and urban comfort. H 2 S emission models are generally theoretical and simplified in terms of environmental conditions. Although air transport characteristics in sewers must play a role in the fate of hydrogen sulfide, only a limited number of studies have investigated this issue. The aim of this study was to better understand H 2 S liquid to gas transfer by highlighting the link between the mass transfer coefficient and the turbulence in the air flow and the water flow. For experimental safety reasons, O 2 was taken as a model compound. The oxygen mass transfer coefficients were obtained using a mass balance in plug flow. The mass transfer coefficient was not impacted by the range of the interface air-flow velocity values tested (0.55-2.28 m·s -1 ) or the water velocity values (0.06-0.55 m·s -1 ). Using the ratio between k L,O 2 to k L,H 2 S , the H 2 S mass transfer behavior in a gravity pipe in the same hydraulic conditions can be predicted.

  18. Determination of pollutant diffusion coefficients in naturally formed biofilms using a single tube extractive membrane bioreactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, S.F.; Splendiani, A.; Freitas dos Santos, L.M.

    A novel technique has been used to determine the effective diffusion coefficients for 1,1,2-trichloroethane (TCE), a nonreacting tracer, in biofilms growing on the external surface of a silicone rubber membrane tube during degradation of 1,2-dichloroethane (DCE) by Xanthobacter autotrophicus GJ10 and monochlorobenzene (MCB) by Pseudomonas JS150. Experiments were carried out in a single tube extractive membrane bioreactor (STEMB), whose configuration makes it possible to measure the transmembrane flux of substrates. A video imaging technique (VIT) was employed for in situ biofilm thickness measurement and recording. Diffusion coefficients of TCE in the biofilms and TCE mass transfer coefficients in the liquidmore » films adjacent to the biofilms were determined simultaneously using a resistances-in-series diffusion model. It was found that the flux and overall mass transfer coefficient of TCE decrease with increasing biofilm thickness, showing the importance of biofilm diffusion on the mass transfer process. Similar fluxes were observed for the nonreacting tracer (TCE) and the reactive substrates (MCB or DCE), suggesting that membrane-attached biofilm systems can be rate controlled primarily by substrate diffusion. The TCE diffusion coefficient in the JS150 biofilm appeared to be dependent on biofilm thickness, decreasing markedly for biofilm thicknesses of >1 mm. The values of the TCE diffusion coefficients in the JS150 biofilms <1-mm thick are approximately twice those in water and fall to around 30% of the water value for biofilms >1-mm thick.« less

  19. [Carbon monoxide tests in a steady state. Uptake and transfer capacity, normal values and lower limits].

    PubMed

    Ramonatxo, M; Préfaut, C; Guerrero, H; Moutou, H; Bansard, X; Chardon, G

    1982-01-01

    The aim of this study was to establish data which would best demonstrate the variations of different tests using Carbon Monoxide as a tracer gas (total and partial functional uptake coefficient and transfer capacity) to establish mean values and lower limits of normal of these tests. Multivariate statistical analysis was used; in the first stage a connection was sought between the fractional uptake coefficient (partial and total) to other parameters, comparing subjects and data. In the second stage the comparison was refined by eliminating the least useful data, trying, despite a small loss of material, to reveal the most important connections, linear or otherwise. The fractional uptake coefficients varied according to sex, also the variation of the partial alveolar-expired fractional uptake equivalent (DuACO) was largely a function of respiratory rate and tidal volume. The alveolar-arterial partial fractional uptake equivalent (DuaCO) depended more on respiratory frequency and age. Finally the total fractional uptake coefficient (DuCO) and the transfer capacity corrected per liter of ventilation (TLCO/V) were functions of these parameters. The last stage of this work, after taking account of the statistical observations consistent with the facts of these physiological hypotheses led to a search for a better way of approaching the laws linking the collected data to the fractional uptake coefficient. The lower limits of normal were arbitrarily defined, separating those 5% of subjects deviating most strongly from the mean. As a result, the relationship between the lower limit of normal and the theoretical mean value was 90% for the partial and total fractional uptake coefficient and 70% for the transfer capacity corrected per liter of ventilation.

  20. Cooling Stability Test of MgB2 Wire Immersed in Liquid Hydrogen under External Magnetic Field

    NASA Astrophysics Data System (ADS)

    Shirai, Yasuyuki; Hikawa, Kyosuke; Shiotsu, Masahiro; Tatsumoto, Hideki; Naruo, Yoshihiro; Kobayashi, Hiroaki; Inagaki, Yoshifumi

    2014-05-01

    Liquid hydrogen (LH2), which has large latent heat, low viscosity coefficient, is expected to be a candidate for a cryogen for superconducting wires, not only MgB2 but also other HTC superconductors. LH2 cooled superconducting wires are expected to have excellent electro-magnetic characteristics, which is necessary to be clear for cooling stability design of LH2 cooled superconducting device, however, due to handling difficulties of LH2, there are only few papers on the properties of LH2 cooled superconductors, especially under external magnetic field. We designed and made an experimental setup which can energize superconducting wires immersed in LH2 with the current of up to 500A under the condition of external magnetic field up to 7 T and pressure up to 1.5 MPa. In order to confirm experimental method and safety operation of the setup, over current tests were carried out using MgB2 superconducting wires under various external magnetic field conditions. Critical current of the test wire at the temperature 21, 24, 27, 29 K under external magnetic fields up to 1.2 T was successfully measured. The resistance of the wire also was measured, while the transport current exceeded the critical current of the wire.

  1. Impact of different thickness of the smooth heated surface on flow boiling heat transfer

    NASA Astrophysics Data System (ADS)

    Strąk, Kinga; Piasecka, Magdalena

    2018-06-01

    This paper presents a comparison of the performance of three smooth heated surfaces with different thicknesses. Analysis was carried out on an experimental setup for flow boiling heat transfer. The most important element of the setup was the test section with a rectangular minichannel, 1.7 mm deep, 16 mm wide and 180 mm long, oriented vertically. The heated element for the FC-72 Fluorinert flowing in the minichannel was designated as a Haynes-230 alloy plate (0.10 mm and 0.45 mm thick) or a Hastelloy X alloy plate (0.65 mm thick). Infrared thermography was used to measure the temperature of the outer plate surface. The local values of the heat transfer coefficient for stationary state conditions were calculated using a simple one-dimensional method. The experimental results were presented as the relationship between the heat transfer coefficients in the subcooled boiling region and the distance along the minichannel length and boiling curves. The highest local heat transfer coefficients were recorded for the surface of 0.10 mm thick heated plate at the outlet and 0.45 mm thick plate at the minichannel inlet. All boiling curves were typical in shape.

  2. Heat Transfer Performance of Functionalized Graphene Nanoplatelet Aqueous Nanofluids

    PubMed Central

    Agromayor, Roberto; Cabaleiro, David; Pardinas, Angel A.; Vallejo, Javier P.; Fernandez-Seara, Jose; Lugo, Luis

    2016-01-01

    The low thermal conductivity of fluids used in many industrial applications is one of the primary limitations in the development of more efficient heat transfer systems. A promising solution to this problem is the suspension of nanoparticles with high thermal conductivities in a base fluid. These suspensions, known as nanofluids, have great potential for enhancing heat transfer. The heat transfer enhancement of sulfonic acid-functionalized graphene nanoplatelet water-based nanofluids is addressed in this work. A new experimental setup was designed for this purpose. Convection coefficients, pressure drops, and thermophysical properties of various nanofluids at different concentrations were measured for several operational conditions and the results are compared with those of pure water. Enhancements in thermal conductivity and in convection heat transfer coefficient reach 12% (1 wt %) and 32% (0.5 wt %), respectively. New correlations capable of predicting the Nusselt number and the friction factor of this kind of nanofluid as a function of other dimensionless quantities are developed. In addition, thermal performance factors are obtained from the experimental convection coefficient and pressure drop data in order to assess the convenience of replacing the base fluid with designed nanofluids. PMID:28773578

  3. About the Role of the Bottleneck/Cork Interface on Oxygen Transfer.

    PubMed

    Lagorce-Tachon, Aurélie; Karbowiak, Thomas; Paulin, Christian; Simon, Jean-Marc; Gougeon, Régis D; Bellat, Jean-Pierre

    2016-09-07

    The transfer of oxygen through a corked bottleneck was investigated using a manometric technique. First, the effect of cork compression on oxygen transfer was evaluated without considering the glass/cork interface. No significant effect of cork compression (at 23% strain, corresponding to the compression level of cork in a bottleneck for still wines) was noticeable on the effective diffusion coefficient of oxygen. The mean value of the effective diffusion coefficient is equal to 10(-8) m(2) s(-1), with a statistical distribution ranging from 10(-10) to 10(-7) m(2) s(-1), which is of the same order of magnitude as for the non-compressed cork. Then, oxygen transfer through cork compressed in a glass bottleneck was determined to assess the effect of the glass/cork interface. In the particular case of a gradient-imposed diffusion of oxygen through our model corked bottleneck system (dry cork without surface treatment; 200 and ∼0 hPa of oxygen on both sides of the sample), the mean effective diffusion coefficient is of 5 × 10(-7) m(2) s(-1), thus revealing the possible importance of the role of the glass/stopper interface in the oxygen transfer.

  4. Impact of Fe powder sintering and soldering in production of porous heating surface on flow boiling heat transfer in minichannels

    NASA Astrophysics Data System (ADS)

    Depczyński, Wojciech; Piasecki, Artur; Piasecka, Magdalena; Strąk, Kinga

    2017-10-01

    This paper focuses on identification of the impact of porous heated surface on flow boiling heat transfer in a rectangular minichannel. The heated element for Fluorinert FC-72 was a thin plate made of Haynes-230. Infrared thermography was used to determine changes in the temperature on its outer smooth side. The porous surface in contact with the fluid in the minichannel was produced in two processes: sintering or soldering of Fe powder to the plate. The results were presented as relationships between the heat transfer coefficient and the distance from the minichannel inlet and as boiling curves. Results obtained for using a smooth heated plate at the saturated boiling region were also presented to compare. In the subcooled boiling region, at a higher heat flux, the heat transfer coefficient was slightly higher for the surface prepared via soldering. In the saturated boiling region, the local heat transfer coefficients obtained for the smooth plate surface were slightly higher than those achieved from the sintered plate surface. The porous structures formed have low thermal conductivity. This may induce noticeable thermal resistance at the diffusion bridges of the sintered structures, in particular within the saturated boiling region.

  5. Heat Transfer Analysis of an Optimized, Flexible Holder System for Freeze-Drying in Dual Chamber Cartridges Using Different State-of-the-Art PAT Tools.

    PubMed

    Korpus, Christoph; Pikal, Michael; Friess, Wolfgang

    2016-11-01

    The aim of this study was to determine the heat transfer characteristics of an optimized flexible holder device, using Tunable Diode Laser Absorption Spectroscopy, the Pressure Rise Test, and the gravimetric procedure. Two different controlled nucleation methods were tested, and an improved sublimation process, "preheated plate," was developed. Tunable Diode Laser Absorption Spectroscopy identified an initial sublimation burst phase. Accordingly, steady-state equations were adapted for the gravimetric procedure, to account for this initial non-steady-state period. The heat transfer coefficient, K DCC , describing the transfer from the holder to the DCC, was the only heat transfer coefficient showing a clear pressure dependence with values ranging from 3.81E-04 cal/(g·cm 2 ·K) at 40 mTorr to 7.38E-04 cal/(g·cm 2 ·K) at 200 mTorr. The heat transfer coefficient, K tot , reflecting the overall energy transfer via the holder, increased by around 24% from 40 to 200 mTorr. This resulted in a pressure-independent sublimation rate of around 42 ± 1.06 mg/h over the whole pressure range. Hence, this pressure-dependent increase in energy transfer completely compensated the decrease in driving force of sublimation. The "flexible holder" shows a substantially reduced impact of atypical radiation, improved drying homogeneity, and ultimately a better transferability of the freeze-drying cycle for process optimization. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  6. Experimental investigation of heat transfer and pressure drop characteristics of non-Newtonian nanofluids flowing in the shell-side of a helical baffle heat exchanger with low-finned tubes

    NASA Astrophysics Data System (ADS)

    Tan, Yunkai; He, Zhenbin; Xu, Tao; Fang, Xiaoming; Gao, Xuenong; Zhang, Zhengguo

    2017-09-01

    An aqueous solution of Xanthan Gum (XG) at a weight fraction as high as 0.2% was used as the base liquid, the stable MWCNTs-dispersed non-Newtonian nanofluids at different weight factions of MWCNTs was prepared. The base fluid and all nanofluids show pseudoplastic (shear-thinning) rheological behavior. Experiments were performed to compare the shell-side forced convective heat transfer coefficient and pressure drop of non-Newtonian nanofluids to those of non-Newtonian base fluid in an integrally helical baffle heat exchanger with low-finned tubes. The experimental results showed that the enhancement of the convective heat transfer coefficient increases with an increase in the Peclet number and the nanoparticle concentration. For nanofluids with 1.0, 0.5 and 0.2 wt% of multi-walled carbon nanotubes (MWCNTs), the heat transfer coefficients respectively augmented by 24.3, 13.2 and 4.7% on average and the pressure drops become larger than those of the base fluid. The comprehensive thermal performance factor is higher than one and increases with an increasing weight fraction of MWCNTs. A remarkable heat transfer enhancement in the shell side of helical baffle heat exchanger with low-finned tubes can be obtained by adding MWCNTs into XG aqueous solution based on thermal resistance analysis. New correlations have been suggested for the shell-side friction coefficient and the Nusselt numbers of non-Newtonian nanofluids and give very good agreement with experimental data.

  7. A parametric heat transfer study for cryogenic ball bearings in SSME HPOTP

    NASA Technical Reports Server (NTRS)

    Chyu, Mingking K.

    1989-01-01

    A numerical modeling is to examine the effects of coolant convective heat transfer coefficient and frictional heating on the local temperature characteristics of a ball element in Space Shuttle Main Engine (SSME) High Pressure Oxidizer Turbopump (HPOTP) bearing. The present modeling uses a control-volume based, finite-difference method to solve the non-dimensionalized heat conduction equation in spherical coordinate system. The dimensionless temperature is found as a function of Biot number, heat flux ratio between the two race contacts, and location in the ball. The current results show that, for a given cooling capability, the ball temperature generally increases almost linearly with the heat input from the race-contacts. This increase is always very high at one of the two contacts. An increase in heat transfer coefficient generally reduces the ball temperature and alleviates the temperature gradient, except for the regions very close to the race contacts. For a 10-fold increase of heat transfer coefficient, temperature decrease is 35 percent for the average over entire ball, and 10 percent at the inner-race contact. The corresponding change of temperature gradient displays opposing trends between the regions immediately adjacent to the contacts and the remaining portion of the ball. The average temperature gradient in the vicinity of both contacts increases approximately 70 to 100 percent. A higher temperature gradient produces excessive thermal stress locally which may be detrimental to the material integrity. This, however, is the only unfavorable issue for an increase of heat transfer coefficient.

  8. Heat Transfer in Glass, Aluminum, and Plastic Beverage Bottles

    ERIC Educational Resources Information Center

    Clark, William M.; Shevlin, Ryan C.; Soffen, Tanya S.

    2010-01-01

    This paper addresses a controversy regarding the effect of bottle material on the thermal performance of beverage bottles. Experiments and calculations that verify or refute advertising claims and represent an interesting way to teach heat transfer fundamentals are described. Heat transfer coefficients and the resistance to heat transfer offered…

  9. Comparing four service delivery models for adolescent girls and young women through the 'Girl Power' study: protocol for a multisite quasi-experimental cohort study.

    PubMed

    Rosenberg, Nora E; Pettifor, Audrey E; Myers, Laura; Phanga, Twambilile; Marcus, Rebecca; Bhushan, Nivedita Latha; Madlingozi, Nomtha; Vansia, Dhrutika; Masters, Avril; Maseko, Bertha; Mtwisha, Lulu; Kachigamba, Annie; Tang, Jennifer; Hosseinipour, Mina C; Bekker, Linda-Gail

    2017-12-14

    In sub-Saharan Africa, adolescent girls and young women (AGYW) face a range of sexual and reproductive health (SRH) challenges. Clinical, behavioural and structural interventions have each reduced these risks and improved health outcomes. However, combinations of these interventions have not been compared with each other or with no intervention at all. The 'Girl Power' study is designed to systematically make these comparisons. Four comparable health facilities in Malawi and South Africa (n=8) were selected and assigned to one of the following models of care: (1) Standard of care : AGYW can receive family planning, HIV testing and counselling (HTC), and sexually transmitted infection (STI) syndromic management in three separate locations with three separate queues with the general population. No youth-friendly spaces, clinical modifications or trainings are offered, (2) Youth-Friendly Health Services (YFHS) : AGYW are meant to receive integrated family planning, HTC and STI services in dedicated youth spaces with youth-friendly modifications and providers trained in YFHS, (3) YFHS+behavioural intervention (BI) : In addition to YFHS, AGYW can attend 12 monthly theory-driven, facilitator-led, interactive sessions on health, finance and relationships, (4) YFHS+BI+conditional cash transfer (CCT) : in addition to YFHS and BI, AGYW receive up to 12 CCTs conditional on monthly BI session attendance.At each clinic, 250 AGYW 15-24 years old (n=2000 total) will be consented, enrolled and followed for 1 year. Each participant will complete a behavioural survey at enrolment, 6 months and 12 months . All clinical, behavioural and CCT services will be captured. Outcomes of interest include uptake of each package element and reduction in HIV risk behaviours. A qualitative substudy will be conducted. This study has received ethical approval from the University of North Carolina Institutional Review Board, the University of Cape Town Human Research Ethics Committee and Malawi's National Health Sciences Research Committee. Study plans, processes and findings will be disseminated to stakeholders, in peer-reviewed journals and at conferences. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. A surface renewal model for unsteady-state mass transfer using the generalized Danckwerts age distribution function

    PubMed Central

    Horvath, Isabelle R.

    2018-01-01

    The recently derived steady-state generalized Danckwerts age distribution is extended to unsteady-state conditions. For three different wind speeds used by researchers on air–water heat exchange on the Heidelberg Aeolotron, calculations reveal that the distribution has a sharp peak during the initial moments, but flattens out and acquires a bell-shaped character with process time, with the time taken to attain a steady-state profile being a strong and inverse function of wind speed. With increasing wind speed, the age distribution narrows significantly, its skewness decreases and its peak becomes larger. The mean eddy renewal time increases linearly with process time initially but approaches a final steady-state value asymptotically, which decreases dramatically with increased wind speed. Using the distribution to analyse the transient absorption of a gas into a large body of liquid, assuming negligible gas-side mass-transfer resistance, estimates are made of the gas-absorption and dissolved-gas transfer coefficients for oxygen absorption in water at 25°C for the three different wind speeds. Under unsteady-state conditions, these two coefficients show an inverse behaviour, indicating a heightened accumulation of dissolved gas in the surface elements, especially during the initial moments of absorption. However, the two mass-transfer coefficients start merging together as the steady state is approached. Theoretical predictions of the steady-state mass-transfer coefficient or transfer velocity are in fair agreement (average absolute error of prediction = 18.1%) with some experimental measurements of the same for the nitrous oxide–water system at 20°C that were made in the Heidelberg Aeolotron. PMID:29892429

  11. Modeling of the Inter-phase Mass Transfer during Cosolvent-Enhanced NAPL Remediation

    NASA Astrophysics Data System (ADS)

    Agaoglu, B.; Scheytt, T. J.; Copty, N. K.

    2012-12-01

    This study investigates the factors influencing inter-phase mass transfer during cosolvent-enhanced NAPL remediation and the ability of the REV (Representative Elementary Volume) modeling approach to simulate these processes. The NAPLs considered in this study consist of pure toluene, pure benzene and known mixtures of these two compounds, while ethanol-water mixtures were selected as the remedial flushing solutions. Batch tests were performed to identify both the equilibrium and non-equilibrium properties of the multiphase system. A series of column flushing experiments involving different NAPLs were conducted for different ethanol contents in the flushing solution and for different operational parameters. Experimental results were compared to numerical simulations obtained with the UTCHEM multiphase flow simulator (Delshad et al., 1996). Results indicate that the velocity of the flushing solution is a major parameter influencing the inter-phase mass transport processes at the pore scale. Depending on the NAPL composition and porous medium properties, the remedial solution may follow preferential flow paths and be subject to reduced contact with the NAPL. This leads to a steep decrease in the apparent mass transfer coefficient. Correlations of the apparent time-dependent mass transfer coefficient as a function of flushing velocity are developed for various porous media. Experimental results also show that the NAPL mass transfer coefficient into the cosolvent solution increases when the NAPL phase becomes mobile. This is attributed to the increase in pore scale contact area between NAPL and the remedial solution when NAPL mobilization occurs. These results suggest the need to define a temporal and spatially variable mass transfer coefficient of the NAPL into the cosolvent solution to reflect the occurrence of subscale preferential flow paths and the transient bypassing of the NAPL mass. The implications of these findings on field scale NAPL remediation with cosolvents are discussed.

  12. The Impact of Married Individuals Learning HIV Status in Malawi: Divorce, Number of Sexual Partners, and Condom Use With Spouses

    PubMed Central

    Kohler, Hans-Peter; Behrman, Jere R.

    2015-01-01

    This article assesses how married individuals’ knowledge of HIV status gained through HIV testing and counseling (HTC) affects divorce, the number of sexual partners, and the use of condoms within marriage. This study improves upon previous studies on this topic because the randomized incentives affecting the propensity to be tested for HIV permit control for selective testing. Instrumental variable probit and linear models are estimated, using a randomized experiment administered as part of the Malawi Longitudinal Study of Families and Health (MLSFH). The results indicate that knowledge of HIV status (1) does not affect chances of divorce for either HIV-negative or HIV-positive respondents; (2) reduces the number of reported sexual partners among HIV-positive respondents; and (3) increases reported condom use with spouses for both HIV-negative and HIV-positive respondents. These results imply that individuals actively respond to information about their HIV status that they learn during HTC, invoking protective behavior against future risk of HIV/AIDS for them-selves and their actual and potential sexual partners. Some limitations of this study are a small sample size for those who are HIV-positive and dependence on self-reported sexual behaviors. PMID:25582891

  13. Nitrogen-Functionalized Hydrothermal Carbon Materials by Using Urotropine as the Nitrogen Precursor.

    PubMed

    Straten, Jan Willem; Schleker, Philipp; Krasowska, Małgorzata; Veroutis, Emmanouil; Granwehr, Josef; Auer, Alexander A; Hetaba, Walid; Becker, Sylvia; Schlögl, Robert; Heumann, Saskia

    2018-03-25

    Nitrogen-containing hydrothermal carbon (N-HTC) materials of spherical particle morphology were prepared by means of hydrothermal synthesis with glucose and urotropine as precursors. The molar ratio of glucose to urotropine has been varied to achieve a continuous increase in nitrogen content. By raising the ratio of urotropine to glucose, a maximal nitrogen fraction of about 19 wt % could be obtained. Decomposition products of both glucose and urotropine react with each other; this opens up a variety of possible reaction pathways. The pH has a pronounced effect on the reaction pathway of the corresponding reaction steps. For the first time, a comprehensive analytical investigation, comprising a multitude of analytical tools and instruments, of a series of nitrogen-containing HTC materials was applied. Functional groups and structural motifs identified were analyzed by means of FTIR spectroscopy, thermogravimetric MS, and solid-state NMR spectroscopy. Information on reaction mechanisms and structural details were obtained by electronic structure calculations that were compared with vibrational spectra of polyfuran or polypyrrole-like groups, which represent structural motifs occurring in the present samples. © 2018 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  14. The Impact of Married Individuals Learning HIV Status in Malawi: Divorce, Number of Sexual Partners, and Condom Use With Spouses.

    PubMed

    Fedor, Theresa M; Kohler, Hans-Peter; Behrman, Jere R

    2015-02-01

    This article assesses how married individuals' knowledge of HIV status gained through HIV testing and counseling (HTC) affects divorce, the number of sexual partners, and the use of condoms within marriage. This study improves upon previous studies on this topic because the randomized incentives affecting the propensity to be tested for HIV permit control for selective testing. Instrumental variable probit and linear models are estimated, using a randomized experiment administered as part of the Malawi Longitudinal Study of Families and Health (MLSFH). The results indicate that knowledge of HIV status (1) does not affect chances of divorce for either HIV-negative or HIV-positive respondents; (2) reduces the number of reported sexual partners among HIV-positive respondents; and (3) increases reported condom use with spouses for both HIV-negative and HIV-positive respondents. These results imply that individuals actively respond to information about their HIV status that they learn during HTC, invoking protective behavior against future risk of HIV/AIDS for themselves and their actual and potential sexual partners. Some limitations of this study are a small sample size for those who are HIV-positive and dependence on self-reported sexual behaviors.

  15. Air-cooling characteristics of simulated grape packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frederick, R.L.; Comunian, F.

    Experimental simulation of the external forced convection on the outside of grape packages was performed. Average heat transfer coefficients for air flow around such containers were found to range from 8 to 13.4 W/(m[sup 2]K). A physical description of the convective process was formulated on the basis of data obtained in three types of experiment. Expressions for the average heat transfer coefficient from single packages in air flow were proposed.

  16. Physics of sub-micron cosmic dust particles

    NASA Technical Reports Server (NTRS)

    Roy, N. L.

    1974-01-01

    Laboratory tests with simulated micrometeoroids to measure the heat transfer coefficient are discussed. Equations for ablation path length for electrically accelerated micrometeoroids entering a gas target are developed which yield guidelines for the laboratory measurement of the heat transfer coefficient. Test results are presented for lanthanum hexaboride (LaB sub 6) microparticles in air, argon, and oxygen targets. The tests indicate the heat transfer coefficient has a value of approximately 0.9 at 30 km/sec, and that it increases to approximately unity at 50 km/sec and above. Test results extend to over 100 km/sec. Results are also given for two types of small particle detectors. A solid state capacitor type detector was tested from 0.61 km/sec to 50 km/sec. An impact ionization type detector was tested from 1.0 to 150 km/sec using LaB sub 6 microparticles.

  17. The features of the modeling the nanofluid flows

    NASA Astrophysics Data System (ADS)

    Rudyak, Valery; Minakov, Andrey

    2018-05-01

    The features of the nanofluid flows modeling are analyzed. In the first part the thermophysical properties (viscosity and thermal conductivity) of nanofluids are discussed in detailed. It was shown that the transport coefficients of nanofluids depend not only on the volume concentration of the particles but also on their size and material. The viscosity increases with decreasing the particle size while the thermal conductivity increases with increasing the particle size. The heat transfer of nanofluid in cylindrical channel and laminar-turbulent transition in some flows are considered. The heat transfer coefficient is determined by the flow mode (laminar or turbulent) of the nanofluid. However it was shown that adding nanoparticles to the coolant significantly influences the heat transfer coefficient. The laminar-turbulent transition begins in all cases earlier (at smaller Reynolds numbers) than for base fluid. In conclusion the possibility of the use of traditional similarity criteria are discussed.

  18. Dissociative charge transfer of H/+/ ions with H2 and D2 molecules from 78 to 330 K

    NASA Technical Reports Server (NTRS)

    Johnsen, R.; Chen, A.; Biondi, M. A.

    1980-01-01

    The dissociative charge transfer of He(+) ions with H2 and D2 molecules has been studied using a temperature-variable drift-tube mass-spectrometer apparatus over the temperature range 78 to 330 K. The binary rate coefficients are small at 300 K, approximately 10 to the -13th to 10 to the -14th cu cm/sec, and only slightly larger at 78 K. Termolecular contributions to the binary rate coefficients are found to be small at 330 K but increase substantially with decreasing temperature. Two-body charge transfer with D2 is found to be slower than with H2 by a factor of 10, in good agreement with recent theoretical predictions, although the measured values of the rate coefficients are larger by a factor of about 4 than the predicted values.

  19. Comparative study of flow condensation in conventional and small diameter tubes

    NASA Astrophysics Data System (ADS)

    Mikielewicz, Dariusz; Andrzejczyk, Rafał

    2012-10-01

    Flow boiling and flow condensation are often regarded as two opposite or symmetrical phenomena. Their description however with a single correlation has yet to be suggested. In the case of flow boiling in minichannels there is mostly encountered the annular flow structure, where the bubble generation is not present. Similar picture holds for the case of inside tube condensation, where annular flow structure predominates. In such case the heat transfer coefficient is primarily dependent on the convective mechanism. In the paper a method developed earlier by the first author is applied to calculations of heat transfer coefficient for inside tube condensation. The method has been verified using experimental data from literature on several fluids in different microchannels and compared to three well established correlations for calculations of heat transfer coefficient in flow condensation. It clearly stems from the results presented here that the flow condensation can be modeled in terms of appropriately devised pressure drop.

  20. Retrospective Cost Adaptive Control with Concurrent Closed-Loop Identification

    NASA Astrophysics Data System (ADS)

    Sobolic, Frantisek M.

    Retrospective cost adaptive control (RCAC) is a discrete-time direct adaptive control algorithm for stabilization, command following, and disturbance rejection. RCAC is known to work on systems given minimal modeling information which is the leading numerator coefficient and any nonminimum-phase (NMP) zeros of the plant transfer function. This information is normally needed a priori and is key in the development of the filter, also known as the target model, within the retrospective performance variable. A novel approach to alleviate the need for prior modeling of both the leading coefficient of the plant transfer function as well as any NMP zeros is developed. The extension to the RCAC algorithm is the use of concurrent optimization of both the target model and the controller coefficients. Concurrent optimization of the target model and controller coefficients is a quadratic optimization problem in the target model and controller coefficients separately. However, this optimization problem is not convex as a joint function of both variables, and therefore nonconvex optimization methods are needed. Finally, insights within RCAC that include intercalated injection between the controller numerator and the denominator, unveil the workings of RCAC fitting a specific closed-loop transfer function to the target model. We exploit this interpretation by investigating several closed-loop identification architectures in order to extract this information for use in the target model.

  1. Thermoregulation and the determinants of heat transfer in Colias butterflies.

    PubMed

    Kingsolver, Joel G; Moffat, Robert J

    1982-04-01

    As a means of exploring behavioral and morphological adaptations for thermoregulation in Colias butterflies, convective heat transfer coefficients of real and model butterflies were measured in a wind tunnel as a function of wind speed and body orientation (yaw angle). Results are reported in terms of a dimensionless heat transfer coefficient (Nusselt number, Nu) and a dimensionless wind speed (Reynolds number, Re), for a wind speed range typical of that experienced by basking Colias in the field. The resultant Nusselt-Reynolds (Nu-Re) plots thus indicate the rates of heat transfer by forced convection as a function of wind speed for particular model geometries.For Reynolds numbers throughout the measured range, Nusselt numbers for C. eurytheme butterflies are consistently lower than those for long cylinders, and are independent of yaw angle. There is significant variation among individual butterflies in heat transfer coefficients throughout the Re range. Model butterflies without artificial fur have Nu-Re relations similar to those for cylinders. Heat transfer in these models depends upon yaw angle, with higher heat transfer at intermediate yaw angles (30-60°); these yaw effects increase with increasing Reynolds number. Models with artificial fur, like real Colias, have Nusselt numbers which are consistently lower than those for models without fur at given Reynolds numbers throughout the Re range. Unlike real Colias, however, the models with fur do show yaw angle effects similar to those for models without fur.The independence of heat loss from yaw angle for real Colias is consistent with field observations indicating no behavioral orientation to wind direction. The presence of fur on the models reduces heat loss but does not affect yaw dependence. The large individual variation in heat transfer coefficients among butterflies is probably due to differences in fur characteristics rather than to differences in wing morphology.Finally, a physical model of a butterfly was constructed which accurately simulates the body temperatures of basking Colias in the field for a variety of radiation and wind velocity conditions. The success of the butterfly simulator in mimicking Colias thermal characteristics confirms our preliminary understanding of the physical bases for and heat transfer mechanisms underlying thermoregulatory adaptations in these butterflies.

  2. Estimation of interfacial area in a packed cross-flow cascade with distillation of ethanol-water, methanol-water, and hexane-heptane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Velaga, A.

    1986-01-01

    Packed cross-flow internals consisting of four and ten stages including the samplers for liquid and vapor were fabricated to fit into the existing distillation column. Experiments were conducted using methanol-water, ethanol-water and hexane-heptane binary mixtures. The experimental data were collected for compositions of inlet and exist streams of cross-flow stages. The overall gas phase height transfer units (H/sub og/) were estimated using the experimental data. H/sub og/ values were compared to those of counter current conditions. The individual mass transfer coefficients in the liquid and vapor phases were estimated using the collected experimental data for degree of separation, flow ratesmore » and physical properties of the binary system used. The physical properties were estimated at an average temperature of the specific cross-flow stage. The mass transfer coefficients were evaluated using three different correlations proposed by Shulman. Onda and Hayashi respectively. The interfacial areas were estimated using the evaluated mass transfer coefficients and the experimental data at each stage of the column for different runs and compared.« less

  3. A 3D analysis of oxygen transfer in a low-cost micro-bioreactor for animal cell suspension culture.

    PubMed

    Yu, P; Lee, T S; Zeng, Y; Low, H T

    2007-01-01

    A 3D numerical model was developed to study the flow field and oxygen transport in a micro-bioreactor with a rotating magnetic bar on the bottom to mix the culture medium. The Reynolds number (Re) was kept in the range of 100-716 to ensure laminar environment for animal cell culture. The volumetric oxygen transfer coefficient (k(L)a) was determined from the oxygen concentration distribution. It was found that the effect of the cell consumption on k(L)a could be negligible. A correlation was proposed to predict the liquid-phase oxygen transfer coefficient (k(Lm)) as a function of Re. The overall oxygen transfer coefficient (k(L)) was obtained by the two-resistance model. Another correlation, within an error of 15%, was proposed to estimate the minimum oxygen concentration to avoid cell hypoxia. By combination of the correlations, the maximum cell density, which the present micro-bioreactor could support, was predicted to be in the order of 10(12) cells m(-3). The results are comparable with typical values reported for animal cell growth in mechanically stirred bioreactors.

  4. Uranium series radionuclides, polonium-210 and lead-210, in the lichen-caribou-wolf food chain of the Northwest Territories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, P.A.; Sheard, J.W.; Swanson, S.

    1994-12-31

    This report examines baseline concentrations and transfer of the uranium decay products polonium-210 and lead-210 in the lichen-caribou-wolf food chain at two locations in the Northwest Territories, Baker Lake and Snowdrift. At each location, concentrations of the two radionuclides were determined in the lichen species Cetraria nivalis and Cladina mitis, and several tissues from caribou and wolves. Baseline concentrations and transfer coefficients within the food chain were compared between the two locations. Lichen samples were also collected from Kasba Lake, a third hunting ground used by northern Saskatchewan hunters. The lichen species chosen were common forage for caribou. Both themore » predominant lichen species at each location and rumen contents were used to estimate the winter diet of caribou in the calculation of transfer coefficients. The results are relevant to environmental monitoring in areas of potential future uranium mining development and the transfer coefficients determined in the study may be used to estimate radionuclide concentrations and radiation doses in future environmental assessments.« less

  5. Hybrid Learning: A Study of Training Environment and Training Transfer in Ecuador

    ERIC Educational Resources Information Center

    Diaz, Karla

    2013-01-01

    Training transfer can be analyzed in the workplace by studying the results of a validated instrument like the Learning Transfer System Inventory (LTSI) developed by Holton and Bates (2011). This correlational study used the Spearman rho correlation coefficient to examine the relationship between transfer design and opportunity to use learning as…

  6. Determination of shelf heat transfer coefficients along the shelf flow path of a freeze dryer using the shelf fluid temperature perturbation approach.

    PubMed

    Kuu, Wei Y; Nail, Steven L; Hardwick, Lisa M

    2007-01-01

    The spatial distribution of local shelf heat transfer coefficients, Ks, was determined by mapping the transient temperature response of the shelf surface along the serpentine internal channels of the shelf while the temperature of the heat transfer fluid was ramped from -40 degrees to 40 degrees C. The solution of a first-order non-steady-state differential equation resulted in a predicted shelf surface temperature as a function of the shelf fluid temperature at any point along the flow path. During the study, the shelf surfaces were maintained under a thermally insulated condition so that the heat transfers by gas conduction and radiation were negligible. To minimize heat conduction by gas, the chamber was evacuated to a low pressure, such as 100 mTorr. To minimize heat transfers between shelves, shelves were moved close together, with a gap of approximately 3 mm between any two shelves, because the shelf surface temperatures at corresponding vertical locations of two shelves are virtually equal. In addition, this also provides a shielding from radiation heat transfer from shelf to walls. Local heat transfer coefficients at the probed locations h(x) ( approximately Ks) were calculated by fitting the experimental shelf temperature response to the theoretical value. While the resulting values of K(s) are in general agreement with previously reported values, the values of Ks close to the inlet are significantly higher than those of other locations of the shelf channel. This observation is most likely attributed to the variation of the flow pattern of heat transfer fluid within the channels.

  7. Mass transfer effects in a gasification riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Breault, Ronald W.; Li, Tingwen; Nicoletti, Phillip

    2013-07-01

    In the development of multiphase reacting computational fluid dynamics (CFD) codes, a number of simplifications were incorporated into the codes and models. One of these simplifications was the use of a simplistic mass transfer correlation for the faster reactions and omission of mass transfer effects completely on the moderate speed and slow speed reactions such as those in a fluidized bed gasifier. Another problem that has propagated is that the mass transfer correlation used in the codes is not universal and is being used far from its developed bubbling fluidized bed regime when applied to circulating fluidized bed (CFB) risermore » reactors. These problems are true for the major CFD codes. To alleviate this problem, a mechanistic based mass transfer coefficient algorithm has been developed based upon an earlier work by Breault et al. This fundamental approach uses the local hydrodynamics to predict a local, time varying mass transfer coefficient. The predicted mass transfer coefficients and the corresponding Sherwood numbers agree well with literature data and are typically about an order of magnitude lower than the correlation noted above. The incorporation of the new mass transfer model gives the expected behavior for all the gasification reactions evaluated in the paper. At the expected and typical design values for the solid flow rate in a CFB riser gasifier an ANOVA analysis has shown the predictions from the new code to be significantly different from the original code predictions. The new algorithm should be used such that the conversions are not over predicted. Additionally, its behaviors with changes in solid flow rate are consistent with the changes in the hydrodynamics.« less

  8. Cooling of Electric Motors Used for Propulsion on SCEPTOR

    NASA Technical Reports Server (NTRS)

    Christie, Robert; Dubois, Authur; Derlaga, Joseph

    2016-01-01

    Benefits of Electric Power: Reduced energy consumption, Lower emissions, Less noise. Traction motors: Permanent magnet, Synchronous, High torque at low rotational speeds, High power density, (High concentration of heat). Annular inlet: Very compatible with PM motors, (Provides cooling where needed, No need for complicated ducting, Leads to a larger motor diameter which is beneficial for motor torque) Effect of prop wash on heat transfer coefficients: Assumed propeller induced turbulence would increase heat transfer coefficients, Holmes, Obara Yip reported 'propeller slipstream showed little if any apparent effect of the slip stream', Derlaga @ LaRC also found little change in heat transfer in the wake of the propeller.

  9. Survey of literature on convective heat transfer coefficients and recovery factors for high atmosphere thermometry

    NASA Technical Reports Server (NTRS)

    Chung, S.

    1973-01-01

    Heat transfer phenomena of rarefied gas flows is discussed based on a literature survey of analytical and experimental rarefied gas dynamics. Subsonic flows are emphasized for the purposes of meteorological thermometry in the high atmosphere. The heat transfer coefficients for three basic geometries are given in the regimes of free molecular flow, transition flow, slip flow, and continuum flow. Different types of heat phenomena, and the analysis of theoretical and experimental data are presented. The uncertainties calculated from the interpolation rule compared with the available experimental data are discussed. The recovery factor for each geometry in subsonic rarefied flows is also given.

  10. Radiation transfer and stellar atmospheres

    NASA Astrophysics Data System (ADS)

    Swihart, T. L.

    This is a revised and expanded version of the author's Basic Physics of Stellar Atmospheres, published in 1971. The equation of transfer is considered, taking into account the intensity and derived quantities, the absorption coefficient, the emission coefficient, the source function, and special integrals for plane media. The gray atmosphere is discussed along with the nongray atmosphere, and aspects of line formation. Topics related to polarization are explored, giving attention to pure polarized radiation, general polarized radiation, transfer in a magnetic plasma, and Rayleigh scattering and the sunlit sky. Physical and astronomical constants, and a number of problems related to the subjects of the book are presented in an appendix.

  11. Identification of multiple magnetizations of the Ediacaran strata in South China

    NASA Astrophysics Data System (ADS)

    Jing, Xianqing; Yang, Zhenyu; Tong, Yabo; Wang, Heng; Xu, Yingchao

    2018-01-01

    A suspected Silurian remagnetization of the Ediacaran strata of South China was proposed decades ago by many researchers, but, there has been no systematic study of its causes and mechanisms. In this study, we investigate the multiphase remagnetization processes that affected the Ediacaran strata and the possible mechanisms of these remagnetization events. We conducted detailed palaeomagnetic, rock magnetic and scanning electron microscope (SEM) studies of samples from the Ediacaran strata in the Jiulongwan (JLWE, JLWS), Qinglinkou (QLK) and Sanxiarenjia (SXRJ) sections in the Three Gorges Area, South China. After removal of a recent viscous remanent magnetization below 150 °C, an intermediate temperature component (ITC; Dg = 27.6°, Ig = 45.3°, N = 12 sites, kg = 184.3, α95 = 3.2° for JLWE; Dg = 22°, Ig = 45.3°, N = 11 sites, kg = 789.2, α95 = 1.6° for JLWS; and Dg = 25.5°, Ig = 52.5°, N = 6 sites, kg = 533.4, α95 = 2.9° for SXRJ) was removed below 300 °C which coincides with the Jurassic results from South China, suggesting a pervasive Jurassic remagnetization. In addition, a high temperature component (HTC; Ds = 84.8°, Is = 19.2°, N = 9 sites, ks = 35.5, α95 = 8.8° for JLWE; Ds = 74.1°, Is = 49.4°, N = 7 sites, ks = 218.9, α95 = 4.1° for JLWS; and Ds = 89.5°, Is = 30.7°, N = 8 sites, ks = 129.2, α95 = 4.9° for SXRJ) was isolated between 300 and 480-540 °C. Rock magnetic and SEM studies suggest that the ITC and HTC are carried by pyrrhotite and magnetite, respectively. SEM observations also demonstrate the occurrence of massive authigenic magnetite in cavities or cracks, mineralogical changes from pyrite to Fe oxides, and the reaction between gypsum and Fe oxides. Based on similarities to the Silurian poles of South China, together with the SEM observations, we suggest that the HTC from the JLWE and SXRJ sections is a Silurian age remagnetization. The oxidation of iron sulphides and thermochemical sulphate reduction induced by the multiple generations of oil and gas in the Ediacaran and Cambrian strata are suggested as the main mechanism for remagnetization. Despite the pervasive Silurian remagnetization of the Ediacaran strata, most of the HTC from the thick-bedded dolostone of Doushantuo Formation Member 3 at the JLWS section appears to carry a primary remanence, because its pole differs from other poles of South China and the results pass both the fold and reversal tests. The relatively low-geothermic conditions and the absence of both hydrocarbon and smectite/illite explain why most results from the Doushantuo Member 3 of JLWS section were not affected by the Silurian remagnetization. This new Ediacaran pole supersedes the previous suspected remagnetized poles, which can be used to constrain the palaeoposition of South China both in Rodinia and Gondwana.

  12. Heat transfer and flow characteristics on a gas turbine shroud.

    PubMed

    Obata, M; Kumada, M; Ijichi, N

    2001-05-01

    The work described in this paper is an experimental investigation of the heat transfer from the main flow to a turbine shroud surface, which may be applicable to ceramic gas turbines. Three kinds of turbine shrouds are considered with a flat surface, a taper surface and a spiral groove surface opposite to the blades in an axial flow turbine of actual turbo-charger. Heat transfer measurements were performed for the experimental conditions of a uniform heat flux or a uniform wall temperature. The effects of the inlet flow angle, rotational speed, and tip clearance on the heat transfer coefficient were clarified under on- and off-design flow conditions. The mean heat transfer coefficient was correlated to the blade Reynolds number and tip clearance, and compared with an experimental correlation and measurements of a flat surface. A comparison was also made for the measurement of static pressure distributions.

  13. Indirect Measurement of Local Condensing Heat-Transfer Coefficient Around Horizontal Finned Tubes

    DTIC Science & Technology

    1987-09-01

    vapor-sidp coefficients exceeded Nusselt values by factors of approximately 7 to 9 (for a constant temperature drop across the condensate film). Honda...3/8 in.) diameter water-cooled copper tubes helically coiled to a height of 457 mm (le In.). The auxiliary condenser was cooled by a continuous...NAVAL POSTGRADUATE SCHOOL Monterey, California , " I - . 0) I DECI 41987S:,• c ý ! i, THESIS INDIRECT MEASUREMENT OF LOCAL CONDENSING HEAT-TRANSFER

  14. Laboratory Experiments and Modeling of Pooled NAPL Dissolution in Porous Media

    NASA Astrophysics Data System (ADS)

    Copty, N. K.; Sarikurt, D. A.; Gokdemir, C.

    2017-12-01

    The dissolution of non-aqueous phase liquids (NAPLs) entrapped in porous media is commonly modeled at the continuum scale as the product of a chemical potential and an interphase mass transfer coefficient, the latter expressed in terms of Sherwood correlations that are related to flow and porous media properties. Because of the lack of precise estimates of the interface area separating the NAPL and aqueous phase, numerous studies have lumped the interfacial area into the interphase mass transfer coefficient. In this paper controlled dissolution experiments from a pooled NAPL were conducted. The immobile NAPL mass is placed at the bottom of a flow cell filled with porous media with water flowing on top. Effluent aqueous phase concentrations were measured for a wide range of aqueous phase velocities and for two types of porous media. To interpret the experimental results, a two-dimensional pore network model of the NAPL dissolution was developed. The well-defined geometry of the NAPL-water interface and the observed effluent concentrations were used to compute best-fit mass transfer coefficients and non-lumped Sherwood correlations. Comparing the concentrations predicted with the pore network model to simple previously used one-dimensional analytic solutions indicates that the analytic model which ignores the transverse dispersion can lead to over-estimation of the mass transfer coefficient. The predicted Sherwood correlations are also compared to previously published data and implications on NAPL remediation strategies are discussed.

  15. Mass Transfer Coefficientin Stirred Tank for p-Cresol Extraction Process from Coal Tar

    NASA Astrophysics Data System (ADS)

    Fardhyanti, D. S.; Tyaningsih, D. S.; Afifah, S. N.

    2017-04-01

    Indonesia is a country that has a lot of coal resources. The Indonesian coal has a low caloric value. Pyrolysis is one of the process to increase the caloric value. One of the by-product of the pyrolysis process is coal tar. It contains a lot of aliphatic or aromatic compounds such asp-cresol (11% v/v). It is widely used as a disinfectant. Extractionof p-Cresol increases the economic value of waste of coal. The aim of this research isto study about mass tranfer coefficient in the baffled stirred tank for p-Cresolextraction from coal tar. Mass transfer coefficient is useful for design and scale up of industrial equipment. Extraction is conducted inthe baffled stirred tank equipped with a four-bladed axial impeller placed vertically in the vessel. Sample for each time processing (5, 10, 15, 20, 25 and 30minutes) was poured into a separating funnel, settled for an hour and separated into two phases. Then the two phases were weighed. The extract phases and raffinate phases were analyzed by Spectronic UV-Vis. The result showed that mixing speed of p-Cresol extraction increasesthe yield of p-Cresol and the mass transfer coefficient. The highest yield of p-Cresol is 49.32% and the highest mass transfer coefficient is 4.757 x 10-6kg/m2s.

  16. In vitro calibration of a system for measurement of in vivo convective heat transfer coefficient in animals

    PubMed Central

    Tangwongsan, Chanchana; Chachati, Louay; Webster, John G; Farrell, Patrick V

    2006-01-01

    Background We need a sensor to measure the convective heat transfer coefficient during ablation of the heart or liver. Methods We built a minimally invasive instrument to measure the in vivo convective heat transfer coefficient, h in animals, using a Wheatstone-bridge circuit, similar to a hot-wire anemometer circuit. One arm is connected to a steerable catheter sensor whose tip is a 1.9 mm × 3.2 mm thin film resistive temperature detector (RTD) sensor. We used a circulation system to simulate different flow rates at 39°C for in vitro experiments using distilled water, tap water and saline. We heated the sensor approximately 5°C above the fluid temperature. We measured the power consumed by the sensor and the resistance of the sensor during the experiments and analyzed these data to determine the value of the convective heat transfer coefficient at various flow rates. Results From 0 to 5 L/min, experimental values of h in W/(m2·K) were for distilled water 5100 to 13000, for tap water 5500 to 12300, and for saline 5400 to 13600. Theoretical values were 1900 to 10700. Conclusion We believe this system is the smallest, most accurate method of minimally invasive measurement of in vivo h in animals and provides the least disturbance of flow. PMID:17067386

  17. Heat Transfer Enhancement in a Helically Coiled Tube with Al2O3/WATER Nanofluid Under Laminar Flow Condition

    NASA Astrophysics Data System (ADS)

    Kumar, P. C. Mukesh; Kumar, J.; Suresh, S.; Babu, K. Praveen

    2012-10-01

    In this experimental investigation, the heat transfer coefficients of a shell and helically coiled tube heat exchanger using Al2O3/water nanofluid under laminar flow condition were studied. The Al2O3 nanoparticles were characterized by X-Ray diffraction (XRD). The Al2O3/water nanofluid at 0.1%, 0.4% and 0.8% particle volume concentration were prepared by using two step method. The prepared nanofluid was characterized by scanning electron microscope (SEM). It is observed that the overall heat transfer coefficient, inner heat transfer coefficient and experimental inner Nusselt number increase while increasing particle volume concentration and increasing inner Dean number. The enhancement of overall heat transfer coefficient was found to be 7%, 16.9% and 24.2% at 0.1%, 0.4% and 0.8% Al2O3/water nanofluid respectively when compared with water. The enhancement of tube side experimental Nusselt number was found to be 17%, 22.9% and 28% at 0.1%, 0.4% and 0.8% particle volume concentration of Al2O3/water nanofluid respectively when compared with water at fixed Dean number. The tests were conducted in the range of 1600 < De < 2700, and 5200 < Re < 8600 under laminar flow condition and counter flow configuration. These enhancements are due to higher thermal conductivity of nanofluid while increasing particle volume concentration and Brownian motion of nanoparticles. It is studied that there is no negative impact on formation of secondary flow and mixing of fluid when nanofluid passes through the helically coiled tube.

  18. Analysis of buoyancy effect on fully developed laminar heat transfer in a rotating tube

    NASA Technical Reports Server (NTRS)

    Siegel, R.

    1985-01-01

    Laminar heat transfer is analyzed in a tube rotating about an axis perpendicular to the tube axis. The solution applies for flow that is either radially outward from the axis of rotation, or radially inward toward the axis of rotation. The conditions are fully developed, and there is uniform heat addition at the tube wall. The analysis is performed by expanding velocities and temperature in power series using the Taylor number as a perturbation parameter. Coriolis and buoyancy forces caused by tube rotation are included, and the solution is calculated through second-order terms. The secondary flow induced by the Coriolis terms always tends to increase the heat transfer coefficient; this effect can dominate for small wall heating. For radial inflow, buoyancy also tends to improve heat transfer. For radial outflow, however, buoyancy tends to reduce heat transfer; for large wall heating this effect can dominate, and there is a net reduction in heat transfer coefficient.

  19. Experimental study of laminar forced convective heat transfer of deionized water based copper (I) oxide nanofluids in a tube with constant wall heat flux

    NASA Astrophysics Data System (ADS)

    Umer, Asim; Naveed, Shahid; Ramzan, Naveed

    2016-10-01

    Nanofluids, having 1-100 nm size particles in any base fluid are promising fluid for heat transfer intensification due to their enhanced thermal conductivity as compared with the base fluid. The forced convection of nanofluids is the major practical application in heat transfer equipments. In this study, heat transfer enhancements at constant wall heat flux under laminar flow conditions were investigated. Nanofluids of different volume fractions (1, 2 and 4 %) of copper (I) oxide nanoparticles in deionized water were prepared using two step technique under mechanical mixing and ultrasonication. The results were investigated by increasing the Reynolds number of the nanofluids at constant heat flux. The trends of Nusselt number variation with dimensionless length (X/D) and Reynolds numbers were studied. It was observed that heat transfer coefficient increases with increases particles volume concentration and Reynolds number. The maximum enhancement in heat transfer coefficient of 61 % was observed with 4 % particle volume concentration at Reynolds number (Re ~ 605).

  20. Influence of drying air parameters on mass transfer characteristics of apple slices

    NASA Astrophysics Data System (ADS)

    Beigi, Mohsen

    2016-10-01

    To efficiently design both new drying process and equipment and/or to improve the existing systems, accurate values of mass transfer characteristics are necessary. The present study aimed to investigate the influence of drying air parameters (i.e. temperature, velocity and relative humidity) on effective diffusivity and convective mass transfer coefficient of apple slices. The Dincer and Dost model was used to determine the mass transfer characteristics. The obtained Biot number indicated that the moisture transfer in the apple slices was controlled by both internal and external resistance. The effective diffusivity and mass transfer coefficient values obtained to be in the ranges of 7.13 × 10-11-7.66 × 10-10 and 1.46 × 10-7-3.39 × 10-7 m s-1, respectively and the both of them increased with increasing drying air temperature and velocity, and decreasing relative humidity. The validation of the model showed that the model predicted the experimental drying curves of the samples with a good accuracy.

  1. Experimental Studies of Heat-Transfer Behavior at a Casting/Water-Cooled-Mold Interface and Solution of the Heat-Transfer Coefficient

    NASA Astrophysics Data System (ADS)

    Zeng, Y. D.; Wang, F.

    2018-02-01

    In this paper, we propose an experimental model for forming an air gap at the casting/mold interface during the solidification process of the casting, with the size and formation time of the air gap able to be precisely and manually controlled. Based on this model, experiments of gravity casting were performed, and on the basis of the measured temperatures at different locations inside the casting and the mold, the inverse analysis method of heat transfer was applied to solve for the heat-transfer coefficient at the casting/mold interface during the solidification process. Furthermore, the impacts of the width and formation time of the air gap on the interface heat-transfer coefficient (IHTC) were analyzed. The results indicate that the experimental model succeeds in forming an air gap having a certain width at any moment during solidification of the casting, thus allowing us to conveniently and accurately study the impact of the air gap on IHTC using the model. In addition, the casting/mold IHTC is found to first rapidly decrease as the air gap forms and then slowly decrease as the solidification process continues. Moreover, as the width of the air gap and the formation time of the air gap increase, the IHTC decreases.

  2. Holodeck-ISS Experience

    NASA Technical Reports Server (NTRS)

    Rainbolt, Phillip

    2016-01-01

    For the duration of my internship here at JSC for the summer 2016 session, the main project that I worked on dealt with hybrid reality simulations of the ISS. As an ER6 intern for the spacecraft software division, the main project that I worked alongside others was with regards to the Holodeck Virtual Reality Project, specifically with the ISS experience, with the use of the HTC Vive and controllers.

  3. Cyberinfrastructure and Scientific Collaboration: Application of a Virtual Team Performance Framework with Potential Relevance to Education. WCER Working Paper No. 2010-12

    ERIC Educational Resources Information Center

    Kraemer, Sara; Thorn, Christopher A.

    2010-01-01

    The purpose of this exploratory study was to identify and describe some of the dimensions of scientific collaborations using high throughput computing (HTC) through the lens of a virtual team performance framework. A secondary purpose was to assess the viability of using a virtual team performance framework to study scientific collaborations using…

  4. Intensive Group Learning and On-Site Services to Improve Sexual and Reproductive Health Among Young Adults in Liberia: A Randomized Evaluation of HealthyActions

    PubMed Central

    Firestone, Rebecca; Moorsmith, Reid; James, Simon; Urey, Marilyn; Greifinger, Rena; Lloyd, Danielle; Hartenberger-Toby, Lisa; Gausman, Jewel; Sanoe, Musa

    2016-01-01

    ABSTRACT Introduction: Young Liberians, particularly undereducated young adults, face substantial sexual and reproductive health (SRH) challenges, with low uptake of contraceptive methods, high rates of unintended pregnancy, and low levels of knowledge about HIV status. The purpose of this study was to assess the impact of a 6-day intensive group learning intervention combined with on-site SRH services (called HealthyActions) among out-of-school young adults, implemented through an existing alternative education program, on uptake of contraception and HIV testing and counseling (HTC). Methods: The intervention was implemented among young women and men ages 15–35 who were enrolled in alternative basic education learning sites in 5 counties of Liberia. We conducted a randomized evaluation to assess program impact. Baseline data were collected in January–March 2014, and endline data in June–July 2014. Key outcomes of condom use, contraceptive use, and HTC were estimated with difference-in-difference models using fixed effects. All analyses were conducted in Stata 13. Results: We assessed outcomes for 1,157 learners at baseline and 1,052 learners at endline, across 29 treatment and 26 control sites. After adjusting for potential confounders, learners in the HealthyActions intervention group were 12% less likely to report never using a condom with a regular partner over the last month compared with the control group (P = .02). Female learners who received HealthyActions were 13% more likely to use any form of modern contraception compared with learners in control sites (P<.001), with the greatest increase in the use of contraceptive implants. Learners in HealthyActions sites were 45% more likely to have received HTC (P<.001). Conclusion: Providing intensive group learning in a supportive environment coupled with on-site health services improved SRH outcomes among participating learners. The focus of HealthyActions on participatory learning for low-literacy populations presents an adaptable solution for health programming across Liberia and the region. PMID:27688717

  5. Cloudsat tropical cyclone database

    NASA Astrophysics Data System (ADS)

    Tourville, Natalie D.

    CloudSat (CS), the first 94 GHz spaceborne cloud profiling radar (CPR), launched in 2006 to study the vertical distribution of clouds. Not only are CS observations revealing inner vertical cloud details of water and ice globally but CS overpasses of tropical cyclones (TC's) are providing a new and exciting opportunity to study the vertical structure of these storm systems. CS TC observations are providing first time vertical views of TC's and demonstrate a unique way to observe TC structure remotely from space. Since December 2009, CS has intersected every globally named TC (within 1000 km of storm center) for a total of 5,278 unique overpasses of tropical systems (disturbance, tropical depression, tropical storm and hurricane/typhoon/cyclone (HTC)). In conjunction with the Naval Research Laboratory (NRL), each CS TC overpass is processed into a data file containing observational data from the afternoon constellation of satellites (A-TRAIN), Navy's Operational Global Atmospheric Prediction System Model (NOGAPS), European Center for Medium range Weather Forecasting (ECMWF) model and best track storm data. This study will describe the components and statistics of the CS TC database, present case studies of CS TC overpasses with complementary A-TRAIN observations and compare average reflectivity stratifications of TC's across different atmospheric regimes (wind shear, SST, latitude, maximum wind speed and basin). Average reflectivity stratifications reveal that characteristics in each basin vary from year to year and are dependent upon eye overpasses of HTC strength storms and ENSO phase. West Pacific (WPAC) basin storms are generally larger in size (horizontally and vertically) and have greater values of reflectivity at a predefined height than all other basins. Storm structure at higher latitudes expands horizontally. Higher vertical wind shear (≥ 9.5 m/s) reduces cloud top height (CTH) and the intensity of precipitation cores, especially in HTC strength storms. Average zero and ten dBZ height thresholds confirm WPAC storms loft precipitation sized particles higher into the atmosphere than in other basins. Two CS eye overpasses (32 hours apart) of a weakening Typhoon Nida in 2009 reveal the collapse of precipitation cores, warm core anomaly and upper tropospheric ice water content (IWC) under steady moderate shear conditions.

  6. How home HIV testing and counselling with follow-up support achieves high testing coverage and linkage to treatment and prevention: a qualitative analysis from Uganda.

    PubMed

    Ware, Norma C; Wyatt, Monique A; Asiimwe, Stephen; Turyamureeba, Bosco; Tumwesigye, Elioda; van Rooyen, Heidi; Barnabas, Ruanne V; Celum, Connie L

    2016-01-01

    The successes of HIV treatment scale-up and the availability of new prevention tools have raised hopes that the epidemic can finally be controlled and ended. Reduction in HIV incidence and control of the epidemic requires high testing rates at population levels, followed by linkage to treatment or prevention. As effective linkage strategies are identified, it becomes important to understand how these strategies work. We use qualitative data from The Linkages Study, a recent community intervention trial of community-based testing with linkage interventions in sub-Saharan Africa, to show how lay counsellor home HIV testing and counselling (home HTC) with follow-up support leads to linkage to clinic-based HIV treatment and medical male circumcision services. We conducted 99 semi-structured individual interviews with study participants and three focus groups with 16 lay counsellors in Kabwohe, Sheema District, Uganda. The participant sample included both HIV+ men and women (N=47) and HIV-uncircumcised men (N=52). Interview and focus group audio-recordings were translated and transcribed. Each transcript was summarized. The summaries were analyzed inductively to identify emergent themes. Thematic concepts were grouped to develop general constructs and framing propositional statements. Trial participants expressed interest in linking to clinic-based services at testing, but faced obstacles that eroded their initial enthusiasm. Follow-up support by lay counsellors intervened to restore interest and inspire action. Together, home HTC and follow-up support improved morale, created a desire to reciprocate, and provided reassurance that services were trustworthy. In different ways, these functions built links to the health service system. They worked to strengthen individuals' general sense of capability, while making the idea of accessing services more manageable and familiar, thus reducing linkage barriers. Home HTC with follow-up support leads to linkage by building "social bridges," interpersonal connections established and developed through repeated face-to-face contact between counsellors and prospective users of HIV treatment and male circumcision services. Social bridges link communities to the service system, inspiring individuals to overcome obstacles and access care.

  7. Long-term organic selenium supplementation overcomes the trade-off between immune and antioxidant systems in pacu (Piaractus mesopotamicus).

    PubMed

    Takahashi, Leonardo Susumu; Biller-Takahashi, Jaqueline Dalbello; Mansano, Cleber Fernando Menegasso; Urbinati, Elisabeth Criscuolo; Gimbo, Rodrigo Yukihiro; Saita, Marcos Vinícius

    2017-01-01

    Selenium (Se) is an essential nutrient for antioxidant defenses in fish because of its role in preventing immunosuppression caused by oxidative stress. In this study it was demonstrated the relation between the oxidative stress and immune status after a long Se supplementation period, as a result of the evaluation of immunological, hematological and antioxidant responses, as well as growth performance of pacu fed diets supplemented with different concentrations of organic selenium (0, 0.3, 0.6, 0.9, and 1.8 mg Se-yeast/kg, but the final analyzed selenium concentrations were 0.72, 0.94, 1.15, 1.57 and 2.51 mg/kg, respectively) for 65 days. Dietary Se supplementation at 1.15 mg Se-yeast/kg (analyzed value) restored the production of antioxidant enzymes (glutathione peroxidase (GPx) and glutathione S-transferase (GST)), and consequently allowed the increased of some immunological parameters (leukocyte respiratory burst activity and lysozyme activity), hematological parameters (red blood cell count (RBC), hematocrit (HTC), mean corpuscular volume (MCV), and white blood cell count (WBC)). Se supplementation in pacu diets at 1.15 mg Se-yeast/kg for 65 days improved immune response and antioxidant defenses, suggesting that oxidative stress impairs immune system response to prevent excessive reactive oxygen species in cells and indicating the occurrence of a physiological trade-off between immune and antioxidant systems. Higher Se levels, such as 1.57 mg Se-yeast/kg increased the leukocyte respiratory burst activity, the WBC and thrombocyte counts, the RBC and HTC, and the GST and GPx enzymes. However, 2.51 mg Se-yeast/kg decreased the lysozyme levels, the WBC and thrombocyte counts, the RBC, HTC and MCV, and the GST and GPx enzymes. Those findings are important to future studies because showed the negative effect of oxidative stress on immunity, and may help to prevent any inhibition of the expected immune response after immunomodulators administration and vaccination. Also it was possible to meet the dietary selenium requirement of pacu, that was estimated to be 1.56 mg/kg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. The effect of nerve blockade on forearm and finger skin blood flow during body heating and cooling.

    PubMed

    Saumet, J L; Degoute, C S; Saumet, M; Abraham, P

    1992-08-01

    To determine the role of the active cutaneous vasodilatator response in forearm and finger skin, direct assessment of only skin blood flow was performed before and after musculocutaneous and median nerve blockade during whole body heating and cooling. Forearm laser Doppler flow (LDF forearm), forearm heat thermal clearance (HTC forearm), and finger laser Doppler flow (LDF finger) were monitored in the nerve blocked skin and contralateral untreated skin (control). In the pre-blockade period, no significant differences were found between experimental and control arm skin. After nerve block a significant increase occurred only in LDF finger, which rose from 4.3 +/- 0.6 to 6.0 +/- 0.5 volts (p less than 0.05). During whole body heating LDF forearm and HTC forearm increased significantly on both arms. The increase in LDF forearm was greater (p less than 0.05) in control (18.3 +/- 1.2 volts) than in nerve blocked skin (14.6 +/- 1.8 volts) and occurred earlier. The same tendency was observed in HTC forearm between nerve blocked skin (0.522 +/- 0.06 W.m-1.degrees C-1) and control 0.671 +/- 0.037 W.m-1.degrees C-1) (NS). LDF raise up to 6.6 +/- 0.5 and 6.8 +/- 0.5 volts in the blocked finger and in the control respectively. During cooling LDF finger in the control decreased to 1.3 +/- 0.1 volt and was significantly (p less than 0.05) lower than in the resting period, and lower than that in the nerve blocked finger (3.4 +/- 0.8 volts) (p less than 0.05). We conclude that the active vasodilatator system plays an important role as far as the timing and the amplitude of the cutaneous vasodilatator response to whole body heating in the forearm but not in the finger. At thermal neutrality, the vascular vasoconstrictor tone is high to the finger but not to the forearm. The vasoconstrictor response to cooling occurred only in the finger.

  9. Experimental Investigation of Flow Condensation in Microgravity

    NASA Technical Reports Server (NTRS)

    Lee, Hyoungsoon; Park, Ilchung; Konishi, Christopher; Mudawar, Issam; May, Rochelle I.; Juergens, Jeffery R.; Wagner, James D.; Hall, Nancy R.; Nahra, Henry K.; Hasan, Mohammed M.; hide

    2013-01-01

    Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to predict the average condensation heat transfer coefficient with varying degrees of success, and a recent correlation is identified for its superior predictive capability, evidenced by a mean absolute error of 21.7%.

  10. Mass and heat transfer in crushed oil shale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carley, J.F.; Straub, J.S.; Ott, L.L.

    1984-04-01

    Heat and mass transfer between gases and oil-shale particles are both important for all proposed retorting processes. Past studies of transfer in packed beds, which have disagreed substantially in their results, have nearly all been done with beds of regular particles of uniform size, whereas oil-shale retorting involves particles of diverse shapes and widely ranging sizes. To resolve these questions, we have made 349 runs in which we measured mass-transfer rates from naphthalene particles of diverse shapes buried in packed beds through which air was passed at room temperature. This technique permits calculation of the mass-transfer coefficient for each activemore » particle in the bed rather than, as in most past studies, for the bed as a whole. The data were analyzed in two ways: (1) by the traditional correlation of Colburn j/sub D/ vs Reynolds number and (2) by multiple regression of the mass-transfer coefficient on air rate, traditional correlation of Colburn j/sub D/ vs Reynolds number and (3) by multiple regression of the mass-transfer coefficient on air rate, sizes of active and inert particles, void fraction, and temperature. Principal findings are: (1) local Reynolds number should be based on active particle size rather than average size for the bed; (2) no appreciable differences were seen between shallow beds and deep ones; (3) mass transfer was 26% faster for spheres and lozenges buried in shale than for all-sphere beds; (4) orientation of lozenges in shale beds has little effect on mass-transfer rate; (5) a useful summarizing equation for either mass or heat transfer in shale beds is log j.epsilon = -.0747 - .6344 log Re + .0592 log/sup 2/Re where j = either j/sub D/ or j/sub H/, the Chilton-Colburn j-factors for mass and heat transfer, Re = the Reynolds number defined for packed beds, and epsilon = the void fraction in the bed. 12 references, 15 figures.« less

  11. Simulation Approach for Microscale Noncontinuum Gas-Phase Heat Transfer

    NASA Astrophysics Data System (ADS)

    Torczynski, J. R.; Gallis, M. A.

    2008-11-01

    In microscale thermal actuators, gas-phase heat transfer from the heated beams to the adjacent unheated substrate is often the main energy-loss mechanism. Since the beam-substrate gap is comparable to the molecular mean free path, noncontinuum gas effects are important. A simulation approach is presented in which gas-phase heat transfer is described by Fourier's law in the bulk gas and by a wall boundary condition that equates the normal heat flux to the product of the gas-solid temperature difference and a heat transfer coefficient. The dimensionless parameters in this heat transfer coefficient are determined by comparison to Direct Simulation Monte Carlo (DSMC) results for heat transfer from beams of rectangular cross section to the substrate at free-molecular to near-continuum gas pressures. This simulation approach produces reasonably accurate gas-phase heat-transfer results for wide ranges of beam geometries and gas pressures. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  12. A Radiation Solver for the National Combustion Code

    NASA Technical Reports Server (NTRS)

    Sockol, Peter M.

    2015-01-01

    A methodology is given that converts an existing finite volume radiative transfer method that requires input of local absorption coefficients to one that can treat a mixture of combustion gases and compute the coefficients on the fly from the local mixture properties. The Full-spectrum k-distribution method is used to transform the radiative transfer equation (RTE) to an alternate wave number variable, g . The coefficients in the transformed equation are calculated at discrete temperatures and participating species mole fractions that span the values of the problem for each value of g. These results are stored in a table and interpolation is used to find the coefficients at every cell in the field. Finally, the transformed RTE is solved for each g and Gaussian quadrature is used to find the radiant heat flux throughout the field. The present implementation is in an existing cartesian/cylindrical grid radiative transfer code and the local mixture properties are given by a solution of the National Combustion Code (NCC) on the same grid. Based on this work the intention is to apply this method to an existing unstructured grid radiation code which can then be coupled directly to NCC.

  13. Direct calculation of 1-octanol-water partition coefficients from adaptive biasing force molecular dynamics simulations.

    PubMed

    Bhatnagar, Navendu; Kamath, Ganesh; Chelst, Issac; Potoff, Jeffrey J

    2012-07-07

    The 1-octanol-water partition coefficient log K(ow) of a solute is a key parameter used in the prediction of a wide variety of complex phenomena such as drug availability and bioaccumulation potential of trace contaminants. In this work, adaptive biasing force molecular dynamics simulations are used to determine absolute free energies of hydration, solvation, and 1-octanol-water partition coefficients for n-alkanes from methane to octane. Two approaches are evaluated; the direct transfer of the solute from 1-octanol to water phase, and separate transfers of the solute from the water or 1-octanol phase to vacuum, with both methods yielding statistically indistinguishable results. Calculations performed with the TIP4P and SPC∕E water models and the TraPPE united-atom force field for n-alkanes show that the choice of water model has a negligible effect on predicted free energies of transfer and partition coefficients for n-alkanes. A comparison of calculations using wet and dry octanol phases shows that the predictions for log K(ow) using wet octanol are 0.2-0.4 log units lower than for dry octanol, although this is within the statistical uncertainty of the calculation.

  14. Digitally Controlled Analog Signal Processing

    DTIC Science & Technology

    1988-04-01

    each analog switch. The third is the parasiti - capacitance at the output (the capacitor side) of each analog switch. This last is of concern only when a...21) where fk (x) tf H(wk) -H(wk) for k = 1, 2,... n, and x denotes the vector containing n-+ I transfer function coefficients, a, a2 ,... am, and bl...b2, .... bt that are non-zero. We wish to solve this system of equations for x, the vector of unknown transfer function coefficients. The modified

  15. The Development of Enhanced Heat Transfer Condenser Tubing

    DTIC Science & Technology

    1973-07-01

    side coeffic ient. The profiled tube condensing coefficient h’ is derived by analogy with the Nusselt ( 8 ) equation for the average condensing ... condensing coefficient value s = 0.925 was derived by Nusselt for laminar flow cnditions. It is well known that under turbulent film flow with waves...DTICSEL ECTE SEPA 0O1981ŕ jjH E DEVELOPME NTI OF ENHANCED HEAT TRANSFER CONDENSER TUBING! I H .EWSON T. D. AODGSON ! 0L L U I-.L V.i 1-- Chemical

  16. Variances in solar collector performance predictions due to different methods of evaluating wind heat transfer coefficients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramsey, J.W.; Charmchi, M.

    1980-11-01

    The performance of several solar collector configurations has been predicted using both inappropriate and appropriate relations to evaluate the wind-related heat transfer coefficient. The combinations analyzed are: one or two covers and a selectively absorbing surface coating, and one or two covers and a nonselectively absorbing surface coating all collectors are of the basic liquid heating type. It is shown that the optimum results are obtained by using a global correlation equation proposed by Sparrow et al. (1979).

  17. Mathematical Models and Calculation of the Coefficients of Heat and Mass Transfer in the Packings of Mechanical-Draft Towers

    NASA Astrophysics Data System (ADS)

    Laptev, A. G.; Lapteva, E. A.

    2017-05-01

    Semiempirical expressions for calculating the average coefficients of heat and mass transfer in the blocks of film-type sprayers are considered. The equations of the Chilton-Colburn hydrodynamic analogy, Prandtl model, generalizations of the hydrodynamic analogy, as well as dimensionless expressions and experimental data of various authors have been used. It is shown that the best agreement with experiment is provided by equations obtained with the aid of the hydrodynamic analogy and Prandtl model.

  18. Warming of Monolithic Structures in Winter

    NASA Astrophysics Data System (ADS)

    Pikus, G. A.; Lebed, A. R.

    2017-11-01

    The present work attempts to develop a mathematical model for calculating the heat transfer coefficient of the fence of monolithic structures erected in winter. The urgency and, at the same time, the practical significance of the research lies in the fact that to date no simple, effective tool has been developed to ensure the elimination of the unfavorable thermally stressed state of a structure’s concrete from maximum equalization of temperatures across its cross-section. The main problem for concrete is a high temperature which leads to a sharp decrease in the quality of erected structures due to developing cracks. This paper based on the well-known Newton’s law and its differential equation demonstrates the formula of concrete cooling and the analysis of its proportionality coefficient. Based on the literature analysis, it is established that the proportionality coefficient is determined by the thermophysical properties of concrete, the size and shape of the structure, and the intensity of its heat exchange with the surrounding medium. A limitation was used on the temperature gradient over the section of the monolithic structure to derive a formula for calculating the reduced heat transfer coefficient of a concrete fence. All mathematical calculations are given for cooling monolithic constructions in the form of plates. At the end of the work an example is given for the calculation of the required reduced heat transfer coefficient for the fence ensuring compliance with the permissible concrete temperature gradient.

  19. An assessment on convective and radiative heat transfer modelling in tubular solid oxide fuel cells

    NASA Astrophysics Data System (ADS)

    Sánchez, D.; Muñoz, A.; Sánchez, T.

    Four models of convective and radiative heat transfer inside tubular solid oxide fuel cells are presented in this paper, all of them applicable to multidimensional simulations. The work is aimed at assessing if it is necessary to use a very detailed and complicated model to simulate heat transfer inside this kind of device and, for those cases when simple models can be used, the errors are estimated and compared to those of the more complex models. For the convective heat transfer, two models are presented. One of them accounts for the variation of film coefficient as a function of local temperature and composition. This model gives a local value for the heat transfer coefficients and establishes the thermal entry length. The second model employs an average value of the transfer coefficient, which is applied to the whole length of the duct being studied. It is concluded that, unless there is a need to calculate local temperatures, a simple model can be used to evaluate the global performance of the cell with satisfactory accuracy. For the radiation heat transfer, two models are presented again. One of them considers radial radiation exclusively and, thus, radiative exchange between adjacent cells is neglected. On the other hand, the second model accounts for radiation in all directions but increases substantially the complexity of the problem. For this case, it is concluded that deviations between both models are higher than for convection. Actually, using a simple model can lead to a not negligible underestimation of the temperature of the cell.

  20. Study of the influence of surfactants on the activity coefficients and mass transfer coefficients of methanol in aqueous mixtures by reversed-flow gas chromatography.

    PubMed

    Kotsalos, Efthimios; Brezovska, Boryana; Sevastos, Dimitrios; Vagena, Artemis; Koliadima, Athanasia; Kapolos, John; Karaiskakis, George

    2017-11-17

    This work focuses on the influences of surfactants on the activity coefficients, γ, of methanol in binary mixtures with water, as well as on the mass transfer coefficients, k c , for the evaporation of methanol, which is a ubiquitous component in the troposphere, from mixtures of methanol with water at various surfactant's and methanol's concentrations. The technique used is the Reversed-Flow Gas Chromatography (R.F.G.C.), a version of Inverse Gas Chromatography, which allows determining both parameters by performing only one experiment for the k c parameter and two experiments for the γ parameter. The k c and γ values decrease in the presence of the three surfactants used (CTAB, SDS, TRITON X-100) at all methanol's and surfactant's concentrations. The decrease in the methanol's molar fraction, at constant number of surfactant films leads to a decrease in the k c and γ values, while the decrease in the surfactant's concentration, at constant methanol's molar fraction leads to an increase in both the k c and γ parameters. Mass transfer coefficients for the evaporation of methanol at the surfactant films, are also calculated which are approximately between 4 and 5 orders of magnitude larger than the corresponding mass transfer coefficients at the liquid films. Finally, thicknesses of the boundary layer of methanol in the mixtures of methanol with water were determined. The quantities found are compared with those given in the literature or calculated theoretically using various empirical equations. The precision of the R.F.G.C. method for measuring γ and k c parameters is approximately high (94.3-98.0%), showing that R.F.G.C. can be used with success not only for the thermodynamic study of solutions, but also for the interphase transport. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Comments on "Modified wind chill temperatures determined by a whole body thermoregulation model and human-based convective coefficients" by Ben Shabat, Shitzer and Fiala (2013) and "Facial convective heat exchange coefficients in cold and windy environments estimated from human experiments" by Ben Shabat and Shitzer (2012)

    NASA Astrophysics Data System (ADS)

    Osczevski, Randall J.

    2014-08-01

    Ben Shabat et al. (Int J Biometeorol 56(4):639-51, 2013) present revised charts for wind chill equivalent temperatures (WCET) and facial skin temperatures (FST) that differ significantly from currently accepted charts. They credit these differences to their more sophisticated calculation model and to the human-based equation that it used for finding the convective heat transfer coefficient (Ben Shabat and Shitzer, Int J Biometeorol 56:639-651, 2012). Because a version of the simple model that was used to create the current charts accurately reproduces their results when it uses the human-based equation, the differences that they found must be entirely due to this equation. In deriving it, Ben Shabat and Shitzer assumed that all of the heat transfer from the surface of their cylindrical model was due to forced convection alone. Because several modes of heat transfer were occurring in the human experiments they were attempting to simulate, notably radiation, their coefficients are actually total external heat transfer coefficients, not purely convective ones, as the calculation models assume. Data from the one human experiment that used heat flux sensors supports this conclusion and exposes the hazard of using a numerical model with several adjustable parameters that cannot be measured. Because the human-based equation is faulty, the values in the proposed charts are not correct. The equation that Ben Shabat et al. (Int J Biometeorol 56(4):639-51, 2013) propose to calculate WCET should not be used.

  2. Heat transfer in fish: are short excursions between habitats a thermoregulatory behaviour to exploit resources in an unfavourable thermal environment?

    PubMed

    Pépino, Marc; Goyer, Katerine; Magnan, Pierre

    2015-11-01

    Temperature is the primary environmental factor affecting physiological processes in ectotherms. Heat-transfer models describe how the fish's internal temperature responds to a fluctuating thermal environment. Specifically, the rate coefficient (k), defined as the instantaneous rate of change in body temperature in relation to the difference between ambient and body temperature, summarizes the combined effects of direct thermal conduction through body mass, passive convection (intracellular and intercellular fluids) and forced convective heat transfer (cardiovascular system). The k-coefficient is widely used in fish ecology to understand how body temperature responds to changes in water temperature. The main objective of this study was to estimate the k-coefficient of brook charr equipped with internal temperature-sensitive transmitters in controlled laboratory experiments. Fish were first transferred from acclimation tanks (10°C) to tanks at 14, 19 or 23°C (warming experiments) and were then returned to the acclimation tanks (10°C; cooling experiments), thus producing six step changes in ambient temperature. We used non-linear mixed models to estimate the k-coefficient. Model comparisons indicated that the model incorporating the k-coefficient as a function of absolute temperature difference (dT: 4, 9 and 13°C) best described body temperature change. By simulating body temperature in a heterogeneous thermal environment, we provide theoretical predictions of maximum excursion duration between feeding and resting areas. Our simulations suggest that short (i.e. <60 min) excursions could be a common thermoregulatory behaviour adopted by cold freshwater fish species to sustain body temperature below a critical temperature threshold, enabling them to exploit resources in an unfavourable thermal environment. © 2015. Published by The Company of Biologists Ltd.

  3. HEAT TRANSFER EVALUATION OF HFC-236EA WITH HIGH PERFORMANCE ENHANCED TUBES IN CONDENSATION AND EVAPORATION

    EPA Science Inventory

    The report gives results of an evaluation of the heat transfer performance of pure hydrofluorocarbon (HFC)-236ea for high performance enhanced tubes which had not been previously used in Navy shipboard chillers. Shell-side heat transfer coefficient data are presented for condensa...

  4. Computational investigation of fluid flow and heat transfer of an economizer by porous medium approach

    NASA Astrophysics Data System (ADS)

    Babu, C. Rajesh; Kumar, P.; Rajamohan, G.

    2017-07-01

    Computation of fluid flow and heat transfer in an economizer is simulated by a porous medium approach, with plain tubes having a horizontal in-line arrangement and cross flow arrangement in a coal-fired thermal power plant. The economizer is a thermal mechanical device that captures waste heat from the thermal exhaust flue gasses through heat transfer surfaces to preheat boiler feed water. In order to evaluate the fluid flow and heat transfer on tubes, a numerical analysis on heat transfer performance is carried out on an 110 t/h MCR (Maximum continuous rating) boiler unit. In this study, thermal performance is investigated using the computational fluid dynamics (CFD) simulation using ANSYS FLUENT. The fouling factor ε and the overall heat transfer coefficient ψ are employed to evaluate the fluid flow and heat transfer. The model demands significant computational details for geometric modeling, grid generation, and numerical calculations to evaluate the thermal performance of an economizer. The simulation results show that the overall heat transfer coefficient 37.76 W/(m2K) and economizer coil side pressure drop of 0.2 (kg/cm2) are found to be conformity within the tolerable limits when compared with existing industrial economizer data.

  5. A Numerical Analysis of Heat Transfer and Effectiveness on Film Cooled Turbine Blade Tip Models

    NASA Technical Reports Server (NTRS)

    Ameri, A. A.; Rigby, D. L.

    1999-01-01

    A computational study has been performed to predict the distribution of convective heat transfer coefficient on a simulated blade tip with cooling holes. The purpose of the examination was to assess the ability of a three-dimensional Reynolds-averaged Navier-Stokes solver to predict the rate of tip heat transfer and the distribution of cooling effectiveness. To this end, the simulation of tip clearance flow with blowing of Kim and Metzger was used. The agreement of the computed effectiveness with the data was quite good. The agreement with the heat transfer coefficient was not as good but improved away from the cooling holes. Numerical flow visualization showed that the uniformity of wetting of the surface by the film cooling jet is helped by the reverse flow due to edge separation of the main flow.

  6. Mathematical Model of Two Phase Flow in Natural Draft Wet-Cooling Tower Including Flue Gas Injection

    NASA Astrophysics Data System (ADS)

    Hyhlík, Tomáš

    2016-03-01

    The previously developed model of natural draft wet-cooling tower flow, heat and mass transfer is extended to be able to take into account the flow of supersaturated moist air. The two phase flow model is based on void fraction of gas phase which is included in the governing equations. Homogeneous equilibrium model, where the two phases are well mixed and have the same velocity, is used. The effect of flue gas injection is included into the developed mathematical model by using source terms in governing equations and by using momentum flux coefficient and kinetic energy flux coefficient. Heat and mass transfer in the fill zone is described by the system of ordinary differential equations, where the mass transfer is represented by measured fill Merkel number and heat transfer is calculated using prescribed Lewis factor.

  7. Heat-transfer tests of aqueous ethylene glycol solutions in an electrically heated tube

    NASA Technical Reports Server (NTRS)

    Bernardo, Everett; Eian, Carroll S

    1945-01-01

    As part of an investigation of the cooling characteristics of liquid-cooled engines, tests were conducted with an electrically heated single-tube heat exchanger to determine the heat-transfer characteristics of an-e-2 ethylene glycol and other ethylene glycol-water mixtures. Similar tests were conducted with water and commercial butanol (n-butyl alcohol) for check purposes. The results of tests conducted at an approximately constant liquid-flow rate of 0.67 pound per second (Reynolds number, 14,500 to 112,500) indicate that at an average liquid temperature 200 degrees f, the heat-transfer coefficients obtained using water, nominal (by volume) 30 percent-70 percent and 70 percent-30 percent glycol-water mixtures are approximately 3.8, 2.8, and 1.4 times higher, respectively, than the heat-transfer coefficients obtained using an-e-2 ethylene glycol.

  8. Estimation of heat transfer coefficients for biomass particles by direct numerical simulation using microstructured particle models in the Laminar regime

    DOE PAGES

    Pecha, M. Brennan; Garcia-Perez, Manuel; Foust, Thomas D.; ...

    2016-11-08

    Here, direct numerical simulation of convective heat transfer from hot gas to isolated biomass particle models with realistic morphology and explicit microstructure was performed over a range of conditions with laminar flow of hot gas (500 degrees C). Steady-state results demonstrated that convective interfacial heat transfer is dependent on the wood species. The computed heat transfer coefficients were shown to vary between the pine and aspen models by nearly 20%. These differences are attributed to the species-specific variations in the exterior surface morphology of the biomass particles. We also quantify variations in heat transfer experienced by the particle when positionedmore » in different orientations with respect to the direction of fluid flow. These results are compared to previously reported heat transfer coefficient correlations in the range of 0.1 < Pr < 1.5 and 10 < Re < 500. Comparison of these simulation results to correlations commonly used in the literature (Gunn, Ranz-Marshall, and Bird-Stewart-Lightfoot) shows that the Ranz-Marshall (sphere) correlation gave the closest h values to our steady-state simulations for both wood species, though no existing correlation was within 20% of both species at all conditions studied. In general, this work exemplifies the fact that all biomass feedstocks are not created equal, and that their species-specific characteristics must be appreciated in order to facilitate accurate simulations of conversion processes.« less

  9. Estimation of heat transfer coefficients for biomass particles by direct numerical simulation using microstructured particle models in the Laminar regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pecha, M. Brennan; Garcia-Perez, Manuel; Foust, Thomas D.

    Here, direct numerical simulation of convective heat transfer from hot gas to isolated biomass particle models with realistic morphology and explicit microstructure was performed over a range of conditions with laminar flow of hot gas (500 degrees C). Steady-state results demonstrated that convective interfacial heat transfer is dependent on the wood species. The computed heat transfer coefficients were shown to vary between the pine and aspen models by nearly 20%. These differences are attributed to the species-specific variations in the exterior surface morphology of the biomass particles. We also quantify variations in heat transfer experienced by the particle when positionedmore » in different orientations with respect to the direction of fluid flow. These results are compared to previously reported heat transfer coefficient correlations in the range of 0.1 < Pr < 1.5 and 10 < Re < 500. Comparison of these simulation results to correlations commonly used in the literature (Gunn, Ranz-Marshall, and Bird-Stewart-Lightfoot) shows that the Ranz-Marshall (sphere) correlation gave the closest h values to our steady-state simulations for both wood species, though no existing correlation was within 20% of both species at all conditions studied. In general, this work exemplifies the fact that all biomass feedstocks are not created equal, and that their species-specific characteristics must be appreciated in order to facilitate accurate simulations of conversion processes.« less

  10. Standard electrode potential, Tafel equation, and the solvation thermodynamics.

    PubMed

    Matyushov, Dmitry V

    2009-06-21

    Equilibrium in the electronic subsystem across the solution-metal interface is considered to connect the standard electrode potential to the statistics of localized electronic states in solution. We argue that a correct derivation of the Nernst equation for the electrode potential requires a careful separation of the relevant time scales. An equation for the standard metal potential is derived linking it to the thermodynamics of solvation. The Anderson-Newns model for electronic delocalization between the solution and the electrode is combined with a bilinear model of solute-solvent coupling introducing nonlinear solvation into the theory of heterogeneous electron transfer. We therefore are capable of addressing the question of how nonlinear solvation affects electrochemical observables. The transfer coefficient of electrode kinetics is shown to be equal to the derivative of the free energy, or generalized force, required to shift the unoccupied electronic level in the bulk. The transfer coefficient thus directly quantifies the extent of nonlinear solvation of the redox couple. The current model allows the transfer coefficient to deviate from the value of 0.5 of the linear solvation models at zero electrode overpotential. The electrode current curves become asymmetric in respect to the change in the sign of the electrode overpotential.

  11. Effectiveness of fins formed by dimples in the form of ball segments

    NASA Astrophysics Data System (ADS)

    Gabdrakhmanov, E. A.; Afonin, G. N.; Glazov, V. S.

    2017-11-01

    One of the famous ways to improve efficiency of a heat exchanger is associated with the topography of the surfaces being in contact with coolants. So, use of hemispherical dimples leads to progressive growth of the relative heat transfer coefficient compared to increase of the relative resistance coefficient. Usually a plate having the spherical dimple intensifiers for heat transfer is considered as a flat one with embedded cavities. However, such a plate can be also considered as the plate with inbuilt fins which are formed by dimples in the form of ball segments. Given that for the flow of fluid (gas) from left to right, the minimum local heat transfer enhancement occurs in the first (left) half of the dimples, and the maximum falls on the edge of the second (right) half, we obtained an analytical solution describing the temperature distribution along the height of the fin. In the solution we used the Harper-Brown approach. Presented are the results of the calculation of the efficiency of the surface on the parameters of the considered fin and on a known value of the average heat transfer coefficient corresponding to the stage of the fluid flow steady state.

  12. Training Data Requirement for a Neural Network to Predict Aerodynamic Coefficients

    NASA Technical Reports Server (NTRS)

    Korsmeyer, David (Technical Monitor); Rajkumar, T.; Bardina, Jorge

    2003-01-01

    Basic aerodynamic coefficients are modeled as functions of angle of attack, speed brake deflection angle, Mach number, and side slip angle. Most of the aerodynamic parameters can be well-fitted using polynomial functions. We previously demonstrated that a neural network is a fast, reliable way of predicting aerodynamic coefficients. We encountered few under fitted and/or over fitted results during prediction. The training data for the neural network are derived from wind tunnel test measurements and numerical simulations. The basic questions that arise are: how many training data points are required to produce an efficient neural network prediction, and which type of transfer functions should be used between the input-hidden layer and hidden-output layer. In this paper, a comparative study of the efficiency of neural network prediction based on different transfer functions and training dataset sizes is presented. The results of the neural network prediction reflect the sensitivity of the architecture, transfer functions, and training dataset size.

  13. Micro thermal diode with glass thermal insulation structure embedded in a vapor chamber

    NASA Astrophysics Data System (ADS)

    Tsukamoto, Takashiro; Hirayanagi, Takashi; Tanaka, Shuji

    2017-04-01

    This paper reports a micro thermal diode based on one-way working fluid circulation driven by surface tension force. In forward mode, working fluid evaporates and condenses at a heated and cooled area, respectively, and the condensed liquid returns to the evaporation area due to the wettability difference. By this vapor-liquid phase change mechanism, the overall heat transfer coefficient becomes high. On the other hand, in reverse mode, no continuous evaporation-condensation cycle exists. The conductive heat loss in reverse mode was minimized by an embedded glass thermal isolation structure, which makes overall heat transfer coefficient low. The test device was made by a standard MEMS process combined with glass reflow and gold bump sealing. The overall heat transfer coefficients of 13 300 \\text{W}~{{\\text{m}}-2}~\\text{K} for forward mode and 4790 \\text{W}~{{\\text{m}}-2}~\\text{K} for reverse mode were measured. The performance index of the micro thermal diode was about 2.8.

  14. Effect of nanofluid concentration on two-phase thermosyphon heat exchanger performance

    NASA Astrophysics Data System (ADS)

    Cieśliński, Janusz T.

    2016-06-01

    An approach - relaying on application of nanofluid as a working fluid, to improve performance of the two-phase thermosyphon heat exchanger (TPTHEx) has been proposed. The prototype heat exchanger consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. Distilled water and nanofluid water-Al2O3 solution were used as working fluids. Nanoparticles were tested at the concentration of 0.01% and 0.1% by weight. A modified Peclet equation and Wilson method were used to estimate the overall heat transfer coefficient of the tested TPTHEx. The obtained results indicate better performance of the TPTHEx with nanofluids as working fluid compared to distilled water, independent of nanoparticle concentration tested. However, increase in nanoparticle concentration results in overall heat transfer coefficient decrease of the TPTHEx examined. It has been observed that, independent of nanoparticle concentration tested, decrease in operating pressure results in evaporation heat transfer coefficient increase.

  15. Experimental investigation of a reticulated porous alumina heat exchanger for high temperature gas heat recovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, A; Chandran, RB; Davidson, JH

    2015-01-22

    The present study presents an experimental study of a prototype counter-flow heat exchanger designed to recover sensible heat from inert and reactive gases flowing through a high temperature solar reactor for splitting CO2. The tube-in-tube heat exchanger is comprised of two concentric alumina tubes, each filled with reticulated porous alumina with a nominal porosity of 80% and pore density of 5 pores per inch (ppi). The RPC provides high heat transfer surface area per unit volume (917 m(-1)) with low pressure drop. Measurements include the permeability, inertial coefficient, overall heat transfer coefficient, effectiveness and pressure drop. For laminar flow andmore » an inlet gas temperature of 1240 K, the overall heat transfer coefficients are 36-41 W m(-2) K-1. The measured performance is in good agreement with a prior CFD model of the heat exchanger. (C) 2014 Elsevier Ltd. All rights reserved.« less

  16. Design of slurry bubble column reactors: novel technique for optimum catalyst size selection contractual origin of the invention

    DOEpatents

    Gamwo, Isaac K [Murrysville, PA; Gidaspow, Dimitri [Northbrook, IL; Jung, Jonghwun [Naperville, IL

    2009-11-17

    A method for determining optimum catalyst particle size for a gas-solid, liquid-solid, or gas-liquid-solid fluidized bed reactor such as a slurry bubble column reactor (SBCR) for converting synthesis gas into liquid fuels considers the complete granular temperature balance based on the kinetic theory of granular flow, the effect of a volumetric mass transfer coefficient between the liquid and the gas, and the water gas shift reaction. The granular temperature of the catalyst particles representing the kinetic energy of the catalyst particles is measured and the volumetric mass transfer coefficient between the gas and liquid phases is calculated using the granular temperature. Catalyst particle size is varied from 20 .mu.m to 120 .mu.m and a maximum mass transfer coefficient corresponding to optimum liquid hydrocarbon fuel production is determined. Optimum catalyst particle size for maximum methanol production in a SBCR was determined to be in the range of 60-70 .mu.m.

  17. Sherwood correlation for dissolution of pooled NAPL in porous media

    NASA Astrophysics Data System (ADS)

    Aydin Sarikurt, Derya; Gokdemir, Cagri; Copty, Nadim K.

    2017-11-01

    The rate of interphase mass transfer from non-aqueous phase liquids (NAPLs) entrapped in the subsurface into the surrounding mobile aqueous phase is commonly expressed in terms of Sherwood (Sh) correlations that are expressed as a function of flow and porous media properties. Because of the lack of precise methods for the estimation of the interfacial area separating the NAPL and aqueous phases, most studies have opted to use modified Sherwood expressions that lump the interfacial area into the interphase mass transfer coefficient. To date, there are only two studies in the literature that have developed non-lumped Sherwood correlations; however, these correlations have undergone limited validation. In this paper controlled dissolution experiments from pooled NAPL were conducted. The immobile NAPL mass is placed at the bottom of a flow cell filled with porous media with water flowing horizontally on top. Effluent aqueous phase concentrations were measured for a wide range of aqueous phase velocities and for two different porous media. To interpret the experimental results, a two-dimensional pore network model of the NAPL dissolution kinetics and aqueous phase transport was developed. The observed effluent concentrations were then used to compute best-fit mass transfer coefficients. Comparison of the effluent concentrations computed with the two-dimensional pore network model to those estimated with one-dimensional analytical solutions indicates that the analytical model which ignores the transport in the lateral direction can lead to under-estimation of the mass transfer coefficient. Based on system parameters and the estimated mass transfer coefficients, non-lumped Sherwood correlations were developed and compared to previously published data. The developed correlations, which are a significant improvement over currently available correlations that are associated with large uncertainties, can be incorporated into future modeling studies requiring non-lumped Sh expressions.

  18. Overall heat transfer coefficient and pressure drop in a typical tubular exchanger employing alumina nano-fluid as the tube side hot fluid

    NASA Astrophysics Data System (ADS)

    Kabeel, A. E.; Abdelgaied, Mohamed

    2016-08-01

    Nano-fluids are used to improve the heat transfer rates in heat exchangers, especially; the shell-and-tube heat exchanger that is considered one of the most important types of heat exchangers. In the present study, an experimental loop is constructed to study the thermal characteristics of the shell-and-tube heat exchanger; at different concentrations of Al2O3 nonmetallic particles (0.0, 2, 4, and 6 %). This material concentrations is by volume concentrations in pure water as a base fluid. The effects of nano-fluid concentrations on the performance of shell and tube heat exchanger have been conducted based on the overall heat transfer coefficient, the friction factor, the pressure drop in tube side, and the entropy generation rate. The experimental results show that; the highest heat transfer coefficient is obtained at a nano-fluid concentration of 4 % of the shell side. In shell side the maximum percentage increase in the overall heat transfer coefficient has reached 29.8 % for a nano-fluid concentration of 4 %, relative to the case of the base fluid (water) at the same tube side Reynolds number. However; in the tube side the maximum relative increase in pressure drop has recorded the values of 12, 28 and 48 % for a nano-material concentration of 2, 4 and 6 %, respectively, relative to the case without nano-fluid, at an approximate value of 56,000 for Reynolds number. The entropy generation reduces with increasing the nonmetallic particle volume fraction of the same flow rates. For increase the nonmetallic particle volume fraction from 0.0 to 6 % the rate of entropy generation decrease by 10 %.

  19. Hydrodynamic characteristics and overall volumetric oxygen transfer coefficient of a new multi-environment bioreactor.

    PubMed

    Behzadian, Farnaz; Yerushalmi, Laleh; Alimahmoodi, Mahmood; Mulligan, Catherine N

    2013-08-01

    The hydrodynamic characteristics and the overall volumetric oxygen transfer coefficient of a new multi-environment bioreactor which is an integrated part of a wastewater treatment system, called BioCAST, were studied. This bioreactor contains several zones with different environmental conditions including aerobic, microaerophilic and anoxic, designed to increase the contaminant removal capacity of the treatment system. The multi-environment bioreactor is designed based on the concept of airlift reactors where liquid is circulated through the zones with different environmental conditions. The presence of openings between the aerobic zone and the adjacent oxygen-depleted microaerophilic zone changes the hydrodynamic properties of this bioreactor compared to the conventional airlift designs. The impact of operating and process parameters, notably the hydraulic retention time (HRT) and superficial gas velocity (U(G)), on the hydrodynamics and mass transfer characteristics of the system was examined. The results showed that liquid circulation velocity (V(L)), gas holdup (ε) and overall volumetric oxygen transfer coefficient (k(L)a(L)) increase with the increase of superficial gas velocity (U(G)), while the mean circulation time (t(c)) decreases with the increase of superficial gas velocity. The mean circulation time between the aerobic zone (riser) and microaerophilic zone (downcomer) is a stronger function of the superficial gas velocity for the smaller openings (1/2 in.) between the two zones, while for the larger opening (1 in.) the mean circulation time is almost independent of U(G) for U(G) ≥ 0.023 m/s. The smaller openings between the two zones provide higher mass transfer coefficient and better zone generation which will contribute to improved performance of the system during treatment operations.

  20. Local heat/mass transfer and pressure drop in a two-pass rib-roughened channel for turbine airfoil cooling

    NASA Technical Reports Server (NTRS)

    Han, J. C.; Chandra, P. R.

    1987-01-01

    The heat transfer characteristics of turbulent air flow in a multipass channel were studied via the naphthalene sublimation technique. The naphthalene-coated test section, consisting of two straight, square channels joined by a 180 deg turn, resembled the internal cooling passages of gas turbine airfoils. The top and bottom surfaces of the test channel were roughened by rib turbulators. The rib height-to-hydraulic diameter ratio (e/D) were 0.063 and 0.094, and the rib pitch-to-height ratio (P/e) were 10 and 20. The local heat/mass transfer coefficients on the roughened top wall and on the smooth divider and side walls of the test channel were determined for three Reynolds numbers of 15, 30, and 60, thousand, and for three angles of attack (alpha) of 90, 60, and 45 deg. Results showed that the local Sherwood numbers on the ribbed walls were 1.5 to 6.5 times those for a fully developed flow in a smooth square duct. The average ribbed-wall Sherwood numbers were 2.5 to 3.5 times higher than the fully developed values, depending on the rib angle of attack and the Reynolds number. The results also indicated that, before the turn, the heat/mass transfer coefficients in the cases of alpha = 60 and 45 deg were higher than those in the case of alpha=90 deg. However, after the turn, the heat/mass transfer coefficients in the oblique-rib cases were lower than those in the transverse rib case. Correlations for the average Sherwood number ratios for individual channel surfaces and for the overall Sherwood number ratios are reported. Correlations for the fully developed friction factors and for the loss coefficients are also provided.

Top