Sample records for transmitted light techniques

  1. Numerical Solution of Light Scattered from and Transmitted through a Rough Dielectric Surface with Applications to Periodic Roughness and Isolated Structures

    NASA Technical Reports Server (NTRS)

    Sun, Wenbo; Videnn, Gorden; Lin, Bing; Hu, Yongxiang

    2007-01-01

    Light scattering and transmission by rough surfaces are of considerable interest in a variety of applications including remote sensing and characterization of surfaces. In this work, the finite-difference time domain technique is applied to calculate the scattered and transmitted electromagnetic fields of an infinite periodic rough surface. The elements of Mueller matrix for scattered light are calculated by an integral of the near fields over a significant number of periods of the surface. The normalized Mueller matrix elements of the scattered light and the spatial distribution of the transmitted flux for a monolayer of micron-sized dielectric spheres on a silicon substrate are presented. The numerical results show that the nonzero Mueller matrix elements of the system of the monolayer of dielectric spheres on a silicon substrate have specific maxima at some scattering angles. These maxima may be used in characterization of the feature of the system. For light transmitted through the monolayer of spheres, our results show that the transmitted energy focuses around the ray passing through centers of the spheres. At other locations, the transmitted flux is very small. The technique also may be used to calculate the perturbance of the electromagnetic field due to the presence of an isolated structure on the substrate.

  2. Imaging three-dimensional light propagation through periodic nanohole arrays using scanning aperture microscopy

    PubMed Central

    Chowdhury, Mustafa H.; Catchmark, Jeffrey M.; Lakowicz, Joseph R.

    2009-01-01

    The authors introduce a technique for three-dimensional (3D) imaging of the light transmitted through periodic nanoapertures using a scanning probe to perform optical sectioning microscopy. For a 4×4 nanohole array, the transmitted light displays intensity modulations along the propagation axis, with the maximum intensity occurring at 450 μm above the surface. The propagating fields show low divergence, suggesting a beaming effect induced by the array. At distances within 25 μm from the surface, they observe subwavelength confinement of light propagating from the individual nanoholes. Hence, this technique can potentially be used to map the 3D distribution of propagating light, with high spatial resolution. PMID:19696912

  3. Peak-to-average power ratio reduction in orthogonal frequency division multiplexing-based visible light communication systems using a modified partial transmit sequence technique

    NASA Astrophysics Data System (ADS)

    Liu, Yan; Deng, Honggui; Ren, Shuang; Tang, Chengying; Qian, Xuewen

    2018-01-01

    We propose an efficient partial transmit sequence technique based on genetic algorithm and peak-value optimization algorithm (GAPOA) to reduce high peak-to-average power ratio (PAPR) in visible light communication systems based on orthogonal frequency division multiplexing (VLC-OFDM). By analysis of hill-climbing algorithm's pros and cons, we propose the POA with excellent local search ability to further process the signals whose PAPR is still over the threshold after processed by genetic algorithm (GA). To verify the effectiveness of the proposed technique and algorithm, we evaluate the PAPR performance and the bit error rate (BER) performance and compare them with partial transmit sequence (PTS) technique based on GA (GA-PTS), PTS technique based on genetic and hill-climbing algorithm (GH-PTS), and PTS based on shuffled frog leaping algorithm and hill-climbing algorithm (SFLAHC-PTS). The results show that our technique and algorithm have not only better PAPR performance but also lower computational complexity and BER than GA-PTS, GH-PTS, and SFLAHC-PTS technique.

  4. Transmitted light microscopy for visualizing the turbulent primary breakup of a microscale liquid jet

    NASA Astrophysics Data System (ADS)

    Reddemann, Manuel A.; Mathieu, Florian; Kneer, Reinhold

    2013-11-01

    Aiming at a maximum spatial resolution and a minimum motion blur, a new simple double-imaging transmitted light microscopy technique is developed in this work enabling a fundamental investigation of primary breakup of a microscale liquid jet. Contrary to conventional far-field visualization techniques, the working distance is minimized to increase the numerical aperture. The resulting images provide information about shapes, length scales and velocities of primary liquid structures. The method is applied to an optically dense spray leaving a 109-μm diesel nozzle at various injection pressures under atmospheric conditions. A phenomenological study on the temporal spray evolution is done with focus on droplet and ligament formation. Different breakup processes are identified and described. It is found that the jet is characterized by long ligaments parallel or angular to the inner jet region. These ligaments result from collapsing films developing at the spray edge. A significant influence of outlet velocity variation on shape and velocity of these ligaments is observed. The experimental results prove that a transmitted light microscopy technique with reduced working distance is an appropriate tool for a better understanding of primary breakup for small-scaled diesel nozzles and a valuable complement to highly complex measurement techniques.

  5. Capturing the Surface Texture and Shape of Pollen: A Comparison of Microscopy Techniques

    PubMed Central

    Sivaguru, Mayandi; Mander, Luke; Fried, Glenn; Punyasena, Surangi W.

    2012-01-01

    Research on the comparative morphology of pollen grains depends crucially on the application of appropriate microscopy techniques. Information on the performance of microscopy techniques can be used to inform that choice. We compared the ability of several microscopy techniques to provide information on the shape and surface texture of three pollen types with differing morphologies. These techniques are: widefield, apotome, confocal and two-photon microscopy (reflected light techniques), and brightfield and differential interference contrast microscopy (DIC) (transmitted light techniques). We also provide a first view of pollen using super-resolution microscopy. The three pollen types used to contrast the performance of each technique are: Croton hirtus (Euphorbiaceae), Mabea occidentalis (Euphorbiaceae) and Agropyron repens (Poaceae). No single microscopy technique provided an adequate picture of both the shape and surface texture of any of the three pollen types investigated here. The wavelength of incident light, photon-collection ability of the optical technique, signal-to-noise ratio, and the thickness and light absorption characteristics of the exine profoundly affect the recovery of morphological information by a given optical microscopy technique. Reflected light techniques, particularly confocal and two-photon microscopy, best capture pollen shape but provide limited information on very fine surface texture. In contrast, transmitted light techniques, particularly differential interference contrast microscopy, can resolve very fine surface texture but provide limited information on shape. Texture comprising sculptural elements that are spaced near the diffraction limit of light (∼250 nm; NDL) presents an acute challenge to optical microscopy. Super-resolution structured illumination microscopy provides data on the NDL texture of A. repens that is more comparable to textural data from scanning electron microscopy than any other optical microscopy technique investigated here. Maximizing the recovery of morphological information from pollen grains should lead to more robust classifications, and an increase in the taxonomic precision with which ancient vegetation can be reconstructed. PMID:22720050

  6. Centralized light-source optical access network based on polarization multiplexing.

    PubMed

    Grassi, Fulvio; Mora, José; Ortega, Beatriz; Capmany, José

    2010-03-01

    This paper presents and demonstrates a centralized light source optical access network based on optical polarization multiplexing technique. By using two optical sources emitting light orthogonally polarized in the Central Node for downstream and upstream operations, the Remote Node is kept source-free. EVM values below telecommunication standard requirements have been measured experimentally when bidirectional digital signals have been transmitted over 10 km of SMF employing subcarrier multiplexing technique in the electrical domain.

  7. An inexpensive active optical remote sensing instrument for assessing aerosol distributions.

    PubMed

    Barnes, John E; Sharma, Nimmi C P

    2012-02-01

    Air quality studies on a broad variety of topics from health impacts to source/sink analyses, require information on the distributions of atmospheric aerosols over both altitude and time. An inexpensive, simple to implement, ground-based optical remote sensing technique has been developed to assess aerosol distributions. The technique, called CLidar (Charge Coupled Device Camera Light Detection and Ranging), provides aerosol altitude profiles over time. In the CLidar technique a relatively low-power laser transmits light vertically into the atmosphere. The transmitted laser light scatters off of air molecules, clouds, and aerosols. The entire beam from ground to zenith is imaged using a CCD camera and wide-angle (100 degree) optics which are a few hundred meters from the laser. The CLidar technique is optimized for low altitude (boundary layer and lower troposphere) measurements where most aerosols are found and where many other profiling techniques face difficulties. Currently the technique is limited to nighttime measurements. Using the CLidar technique aerosols may be mapped over both altitude and time. The instrumentation required is portable and can easily be moved to locations of interest (e.g. downwind from factories or power plants, near highways). This paper describes the CLidar technique, implementation and data analysis and offers specifics for users wishing to apply the technique for aerosol profiles.

  8. Small, Optically-Driven Power Source

    NASA Technical Reports Server (NTRS)

    Cockrum, Richard H.; Wang, Ke-Li J.

    1988-01-01

    Power transmitted along fiber-optic cables. Transmitted as infrared light along fiber-optic cable, converted to electricity to supply small electronic circuit. Power source and circuit remains electrically isolated from each other for safety or reduces electromagnetic interference. Array of diodes made by standard integrated-circuit techniques and packaged for mounting at end of fiber-optic cable.

  9. A new encoding scheme for visible light communications with applications to mobile connections

    NASA Astrophysics Data System (ADS)

    Benton, David M.; St. John Brittan, Paul

    2017-10-01

    A new, novel and unconventional encoding scheme called concurrent coding, has recently been demonstrated and shown to offer interesting features and benefits in comparison to conventional techniques, such as robustness against burst errors and improved efficiency of transmitted power. Free space optical communications can suffer particularly from issues of alignment which requires stable, fixed links to be established and beam wander which can interrupt communications. Concurrent coding has the potential to help ease these difficulties and enable mobile, flexible optical communications to be implemented through the use of a source encoding technique. This concept has been applied for the first time to optical communications where standard light emitting diodes (LEDs) have been used to transmit information encoded with concurrent coding. The technique successfully transmits and decodes data despite unpredictable interruptions to the transmission causing significant drop-outs to the detected signal. The technique also shows how it is possible to send a single block of data in isolation with no pre-synchronisation required between transmitter and receiver, and no specific synchronisation sequence appended to the transmission. Such systems are robust against interference - intentional or otherwise - as well as intermittent beam blockage.

  10. Paper area density measurement from forward transmitted scattered light

    DOEpatents

    Koo, Jackson C.

    2001-01-01

    A method whereby the average paper fiber area density (weight per unit area) can be directly calculated from the intensity of transmitted, scattered light at two different wavelengths, one being a non-absorpted wavelength. Also, the method makes it possible to derive the water percentage per fiber area density from a two-wavelength measurement. In the optical measuring technique optical transmitted intensity, for example, at 2.1 microns cellulose absorption line is measured and compared with another scattered, optical transmitted intensity reference in the nearby spectrum region, such as 1.68 microns, where there is no absorption. From the ratio of these two intensities, one can calculate the scattering absorption coefficient at 2.1 microns. This absorption coefficient at this wavelength is, then, experimentally correlated to the paper fiber area density. The water percentage per fiber area density can be derived from this two-wavelength measurement approach.

  11. Window flaw detection by backscatter lighting

    NASA Technical Reports Server (NTRS)

    Crockett, L. K.; Minton, F. R.

    1978-01-01

    Portable fiber-optic probe detects tiny flaws in transparent materials. Probe transmits light through surface to illuminate interior of material by backscattering off its edges. Light-sensitive contact paper records scratch pattern. Technique can be used for rapid visual checks. Flexible fiber optics are safely used in explosive or flammable areas; they present no hazard of breakage or contamination in controlled environments.

  12. Optimisation approaches for concurrent transmitted light imaging during confocal microscopy.

    PubMed

    Collings, David A

    2015-01-01

    The transmitted light detectors present on most modern confocal microscopes are an under-utilised tool for the live imaging of plant cells. As the light forming the image in this detector is not passed through a pinhole, out-of-focus light is not removed. It is this extended focus that allows the transmitted light image to provide cellular and organismal context for fluorescence optical sections generated confocally. More importantly, the transmitted light detector provides images that have spatial and temporal registration with the fluorescence images, unlike images taken with a separately-mounted camera. Because plants often provide difficulties for taking transmitted light images, with the presence of pigments and air pockets in leaves, this study documents several approaches to improving transmitted light images beginning with ensuring that the light paths through the microscope are correctly aligned (Köhler illumination). Pigmented samples can be imaged in real colour using sequential scanning with red, green and blue lasers. The resulting transmitted light images can be optimised and merged in ImageJ to generate colour images that maintain registration with concurrent fluorescence images. For faster imaging of pigmented samples, transmitted light images can be formed with non-absorbed wavelengths. Transmitted light images of Arabidopsis leaves expressing GFP can be improved by concurrent illumination with green and blue light. If the blue light used for YFP excitation is blocked from the transmitted light detector with a cheap, coloured glass filters, the non-absorbed green light will form an improved transmitted light image. Changes in sample colour can be quantified by transmitted light imaging. This has been documented in red onion epidermal cells where changes in vacuolar pH triggered by the weak base methylamine result in measurable colour changes in the vacuolar anthocyanin. Many plant cells contain visible levels of pigment. The transmitted light detector provides a useful tool for documenting and measuring changes in these pigments while maintaining registration with confocal imaging.

  13. Light diffusing fiber optic chamber

    DOEpatents

    Maitland, Duncan J.

    2002-01-01

    A light diffusion system for transmitting light to a target area. The light is transmitted in a direction from a proximal end to a distal end by an optical fiber. A diffusing chamber is operatively connected to the optical fiber for transmitting the light from the proximal end to the distal end and transmitting said light to said target area. A plug is operatively connected to the diffusing chamber for increasing the light that is transmitted to the target area.

  14. Polarized Light Reflected and Transmitted by Thick Rayleigh Scattering Atmospheres

    NASA Astrophysics Data System (ADS)

    Natraj, Vijay; Hovenier, J. W.

    2012-03-01

    Accurate values for the intensity and polarization of light reflected and transmitted by optically thick Rayleigh scattering atmospheres with a Lambert surface underneath are presented. A recently reported new method for solving integral equations describing Chandrasekhar's X- and Y-functions is used. The results have been validated using various tests and techniques, including the doubling-adding method, and are accurate to within one unit in the eighth decimal place. Tables are stored electronically and expected to be useful as benchmark results for the (exo)planetary science and astrophysics communities. Asymptotic expressions to obtain Stokes parameters for a thick layer from those of a semi-infinite atmosphere are also provided.

  15. Photovoltaic device having light transmitting electrically conductive stacked films

    DOEpatents

    Weber, Michael F.; Tran, Nang T.; Jeffrey, Frank R.; Gilbert, James R.; Aspen, Frank E.

    1990-07-10

    A light transmitting electrically conductive stacked film, useful as a light transmitting electrode, including a first light transmitting electrically conductive layer, having a first optical thickness, a second light transmitting layer, having a second optical thickness different from the optical thickness of the first layer, and an electrically conductive metallic layer interposed between and in initimate contact with the first and second layers.

  16. Hardware Implementation of Multiple Fan Beam Projection Technique in Optical Fibre Process Tomography

    PubMed Central

    Rahim, Ruzairi Abdul; Fazalul Rahiman, Mohd Hafiz; Leong, Lai Chen; Chan, Kok San; Pang, Jon Fea

    2008-01-01

    The main objective of this project is to implement the multiple fan beam projection technique using optical fibre sensors with the aim to achieve a high data acquisition rate. Multiple fan beam projection technique here is defined as allowing more than one emitter to transmit light at the same time using the switch-mode fan beam method. For the thirty-two pairs of sensors used, the 2-projection technique and 4-projection technique are being investigated. Sixteen sets of projections will complete one frame of light emission for the 2-projection technique while eight sets of projection will complete one frame of light emission for the 4-projection technique. In order to facilitate data acquisition process, PIC microcontroller and the sample and hold circuit are being used. This paper summarizes the hardware configuration and design for this project. PMID:27879885

  17. Improvement in Suppression of Pulsed Nd:YAG Laser Light With Iodine Absorption Cells for Filtered Rayleigh Scattering Measurements

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard G.; Buggele, Alvin E

    1997-01-01

    Filtered Rayleigh scattering using iodine absorption cells is an effective technique for obtaining density, temperature, and velocity measurements in high speed confined flows. By tuning a single frequency laser to a strong iodine absorption line, stray scattered laser light can be greatly suppressed. For example, the minimum transmission predicted by an iodine absorption model calculation is less than 10(exp -5) at the 18788.44/cm line using a 200 mm absorption cell containing iodine vapor at 0.46 T. Measurements obtained by other researches using a CW Nd:YAG laser agree with the model calculations. However, measurements made by us and by others using Q-switched, injection-seeded, frequency doubled Nd:YAG lasers only show minimum transmission of about 3 x 10(exp -3). This greatly reduces the applicability of the filtered Rayleigh scattering technique using these lasers in experiments having large amounts of stray scattered laser light. The purposes of the present study are to characterize the spectrum of the excess light transmitted by the iodine cell and to make changes to the laser to reduce the transmitted laser light. Transmission data as a function of laser frequency for the iodine absorption line at 18788.44/cm are presented. A planar mirror Fabry-Perot interferometer was used to characterize the frequency spectrum of the light passed through the cell. Measurements taken with the laser tuned to the center of the iodine absorption line show the light transmitted through the iodine cell to have a component with a bandwidth of about 40 GHz. This is probably caused by other modes in the laser that exist in spite of the single frequency injection beam. A second broadband component was also observed, possibly caused by the laser flash lamps or by fluorescence. An intracavity etalon was installed in the laser oscillator cavity to suppress the 40 GHz component. Measurements taken with the etalon tuned to the injection frequency showed a reduction in the transmitted laser light. This improvement allows the iodine cell to block significantly more of the stray laser light in filtered Rayleigh scattering experiments. Examples are given of filtered Rayleigh scattering measurements showing the effect of the etalon on measurements taken in a Mach 3 flow in the NASA Lewis 4 inch by 10 inch supersonic wind tunnel.

  18. Laser Imaging Polarimetry of Nacre.

    PubMed

    Jones, Joshua A; Metzler, Rebecca A; D'Addario, Anthony J; Burgess, Carrie; Regan, Brian; Spano, Samantha; Cvarch, Ben A; Galvez, Enrique J

    2018-03-25

    Nacre is a complex biomaterial made of aragonite-tablet bricks and organic mortar that is considerably resilient against breakage. Nacre has been studied with a wide range of laboratory techniques, leading to understanding key fundamentals, and informing the creation of bio-inspired materials. In this article we present an optical polarimetric technique to investigate nacre, taking advantage of the translucence and birefringence of its micro-components. We focus our study on three classes of mollusks that have nacreous shells: bivalve (Pinctada fucata), gastropod (Haliotis asisina and Haliotis rufescens) and cephalopod (Nautilus pompilius). We sent polarized light from a laser through thin samples of nacre and did imaging polarimetry of the transmitted light. We observed clear distinctions between the structures of bivalve and gastropod, due to the spatial variation of their birefringence. The patterns for cephalopod were more similar to bivalve than gastropod. Bleaching of the samples disrupted the transmitted light. Subsequent refilling of the bivalve and gastropod nacre samples with oil produced optical patterns similar to those of unbleached samples. In cephalopod samples we found that bleaching produced irreversible changes in the optical pattern. This article is protected by copyright. All rights reserved.

  19. Stand-alone scattering optical device using holographic photopolymer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Park, Jongchan; Lee, KyeoReh; Park, YongKeun

    2016-03-01

    When a light propagates through highly disordered medium, its optical parameters such as amplitude, phase and polarization states are completely scrambled because of multiple scattering events. Since the multiple scattering is a fundamental optical process that contains extremely high degrees of freedom, optical information of a transmitted light is totally mingled. Until recently, the presence of multiple scattering in an inhomogeneous medium is considered as a major obstacle when manipulating a light transmitting through the medium. However, a recent development of wavefront shaping techniques enable us to control the propagation of light through turbid media; a light transmitting through a turbid medium can be effectively controlled by modulating the spatial profile of the incident light using spatial light modulator. In this work, stand-alone scattering optical device is proposed; a holographic photopolymer film, which is much economic compared to the other digital spatial light modulators, is used to record and reconstruct permanent wavefront to generate optical field behind a scattering medium. By employing our method, arbitrary optical field can be generated since the scattering medium completely mixes all the optical parameters which allow us to access all the optical information only by modulating spatial phase profile of the impinging wavefront. The method is experimentally demonstrated in both the far-field and near-field regime where it shows promising fidelity and stability. The proposed stand-alone scattering optical device will opens up new avenues for exploiting the randomness inherent in disordered medium.

  20. High efficiency light source using solid-state emitter and down-conversion material

    DOEpatents

    Narendran, Nadarajah; Gu, Yimin; Freyssinier, Jean Paul

    2010-10-26

    A light emitting apparatus includes a source of light for emitting light; a down conversion material receiving the emitted light, and converting the emitted light into transmitted light and backward transmitted light; and an optic device configured to receive the backward transmitted light and transfer the backward transmitted light outside of the optic device. The source of light is a semiconductor light emitting diode, a laser diode (LD), or a resonant cavity light emitting diode (RCLED). The down conversion material includes one of phosphor or other material for absorbing light in one spectral region and emitting light in another spectral region. The optic device, or lens, includes light transmissive material.

  1. Research on characteristics of forward scattering light based on Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Ding, Kun; Jin, Wei-qi

    2008-03-01

    In ocean inspection, laser system has the advantages of high precision, high efficiency and being enacted on the temperature or salinity of seawater. It has been developed greatly in recent years. But it is not yet a mature inspection technique because of the complicacy of oceanic channel and water-scattering. There are many problems to be resolved. In this paper, the work principle and of general developing situation of ocean lidar techniques are introduced first. The author points out that the intense scattering and absorbing acting on light by water is the bottleneck to limit the development of ocean lidar. The Monet Carlo method is adopted finally to be a basal way of study in this paper after discussing several method of studying the light transmitting in seawater. Based on the theory of photon transmitted in the seawater and the particularity of underwater target detecting, we have studied the characters of laser scattering on underwater target surface and spatial and temporal characters of forward scattering. Starting from the particularity of underwater target detecting, a new model to describe the characters of laser scattering is presented. Based on this model, we developed the fast arithmetic, which enhanced the computation speed greatly and the precision was also assured. It made detecting real-time realizable. Basing on the Monte Carlo simulation and starting from the theory of photon transmitted in the seawater, we studied how the parameters of water quality and other systemic parameters affect the light forward scattering through seawater at spatial and temporal region and provided the theoretical sustentation of enhancing the SNR and operational distance.

  2. Influence of particle size distribution on reflected and transmitted light from clouds.

    PubMed

    Kattawar, G W; Plass, G N

    1968-05-01

    The light reflected and transmitted from clouds with various drop size distributions is calculated by a Monte Carlo technique. Six different models are used for the drop size distribution: isotropic, Rayleigh, haze continental, haze maritime, cumulus, and nimbostratus. The scattering function for each model is calculated from the Mie theory. In general, the reflected and transmitted radiances for the isotropic and Rayleigh models tend to be similar, as are those for the various haze and cloud models. The reflected radiance is less for the haze and cloud models than for the isotropic and Rayleigh models/except for an angle of incidence near the horizon when it is larger around the incident beam direction. The transmitted radiance is always much larger for the haze and cloud models near the incident direction; at distant angles it is less for small and moderate optical thicknesses and greater for large optical thicknesses (all comparisons to isotropic and Rayleigh models). The downward flux, cloud albedo, and ean optical path are discussed. The angular spread of the beam as a function of optical thickness is shown for the nimbostratus model.

  3. Reflection technique for thermal mapping of semiconductors

    DOEpatents

    Walter, Martin J.

    1989-06-20

    Semiconductors may be optically tested for their temperatures by illuminating them with tunable monochromatic electromagnetic radiation and observing the light reflected off of them. A transition point will occur when the wavelength of the light corresponds with the actual band gap energy of the semiconductor. At the transition point, the image of the semiconductor will appreciably darken as the light is transmitted through it, rather than being reflected off of it. The wavelength of the light at the transition point corresponds to the actual band gap energy and the actual temperature of the semiconductor.

  4. Setting up a Rayleigh Scattering Based Flow Measuring System in a Large Nozzle Testing Facility

    NASA Technical Reports Server (NTRS)

    Panda, Jayanta; Gomez, Carlos R.

    2002-01-01

    A molecular Rayleigh scattering based air density measurement system has been built in a large nozzle testing facility at NASA Glenn Research Center. The technique depends on the light scattering by gas molecules present in air; no artificial seeding is required. Light from a single mode, continuous wave laser was transmitted to the nozzle facility by optical fiber, and light scattered by gas molecules, at various points along the laser beam, is collected and measured by photon-counting electronics. By placing the laser beam and collection optics on synchronized traversing units, the point measurement technique is made effective for surveying density variation over a cross-section of the nozzle plume. Various difficulties associated with dust particles, stray light, high noise level and vibration are discussed. Finally, a limited amount of data from an underexpanded jet are presented and compared with expected variations to validate the technique.

  5. Spectral ballistic imaging: a novel technique for viewing through turbid or obstructing media.

    PubMed

    Granot, Er'el; Sternklar, Shmuel

    2003-08-01

    We propose a new method for viewing through turbid or obstructing media. The medium is illuminated with a modulated cw laser and the amplitude and phase of the transmitted (or reflected) signal is measured. This process takes place for a set of wavelengths in a certain wide band. In this way we acquire the Fourier transform of the temporal output. With this information we can reconstruct the temporal shape of the transmitted signal by computing the inverse transform. The proposed method benefits from the advantages of the first-light technique: high resolution, simple algorithms, insensitivity to boundary condition, etc., without suffering from its main deficiencies: complex and expensive equipment.

  6. Metal-clad waveguide characterization for contact-based light transmission into tissue

    NASA Astrophysics Data System (ADS)

    Chininis, Jeffrey; Whiteside, Paul; Hunt, Heather K.

    2016-02-01

    As contemporary laser dermatology procedures, like tattoo removal and skin resurfacing, become more popular, the complications of their operation are also becoming more prevalent. Frequent incidences of over-exposure, ocular injury, and excessive thermal damage represent mounting concerns for those seeking such procedures; moreover, each of these problems is a direct consequence of the standard, free-space method of laser transmission predominantly used in clinical settings. Therefore, an alternative method of light transmission is needed to minimize these problems. Here, we demonstrate and characterize an alternative method that uses planar waveguides to deliver light into sample tissue via direct contact. To do this, slab substrates made from glass were clad in layers of titanium and silver, constraining the light within the waveguide along the waveguide's length. By creating active areas on the waveguide surface, the propagating light could then optically tunnel into the tissue sample, when the waveguide was brought into contact with the tissue. SEM and EDS were used to characterize the metal film thickness and deposition rates onto the glass substrates. Laser light from a Q-switched Nd:YAG source operating at 532nm was coupled into the waveguide and transmitted into samples of pig skin. The amount of light transmitted was measured using photoacoustics techniques, in conjunction with a photodiode and integrating sphere. Transmitting light into tissue in this manner effectively resolves or circumvents the complications caused by free-space propagation methods as it reduces the operating distance to 0, which prevents hazardous back-reflections and allows for the ready incorporation of contact cooling technologies.

  7. Aqueous carrier waveguide in a flow cytometer

    DOEpatents

    Mariella, Jr., Raymond P.; van den Engh, Gerrit; Northrup, M. Allen

    1995-01-01

    The liquid of a flow cytometer itself acts as an optical waveguide, thus transmitting the light to an optical filter/detector combination. This alternative apparatus and method for detecting scattered light in a flow cytometer is provided by a device which views and detects the light trapped within the optical waveguide formed by the flow stream. A fiber optic or other light collecting device is positioned within the flow stream. This provides enormous advantages over the standard light collection technique which uses a microscope objective. The signal-to-noise ratio is greatly increased over that for right-angle-scattered light collected by a microscope objective, and the alignment requirements are simplified.

  8. Ultrasonic modulation of tissue optical properties in ex vivo porcine skin to improve transmitted transdermal laser intensity.

    PubMed

    Whiteside, Paul J D; Qian, Chenxi; Golda, Nicholas; Hunt, Heather K

    2017-09-01

    Applications of light-based energy devices involving optical targets within the dermis frequently experience negative side-effects resultant from surface scattering and excess optical absorption by epidermal melanin. As a broadband optical absorber, melanin decreases the efficacy of light-based treatments throughout the ultraviolet, visible, and near-infrared spectra while also generating additional heat within the surface tissue that can lead to inflammation or tissue damage. Consequently, procedures may be performed using greater energy densities to ensure that the target receives a clinically relevant dose of light; however, such practices are limited, as doing so tends to exacerbate the detrimental complications resulting from melanin absorption of treatment light. The technique presented herein represents an alternative method of operation aimed at increasing epidermal energy fluence while mitigating excess absorption by unintended chromophores. The approach involves the application of continuously pulsed ultrasound to modulate the tissue's optical properties and thereby improve light transmission through the epidermis. To demonstrate the change in optical properties, pulsed light at a wavelength of 532 nm from a Q-switched Nd:YAG laser was transmitted into 4 mm thick samples of porcine skin, comprised of both epidermal and dermal tissue. The light was transmitted using an optical waveguide, which allowed for an ultrasonic transducer to be incorporated for simultaneous paraxial pulsation in parallel with laser operation. Light transmitted through the tissue was measured by a photodiode attached to an integrating sphere. Increasing the driving voltage of ultrasonic pulsation resulted in an increase in mean transmitted optical power of up to a factor of 1.742 ± 0.0526 times the control, wherein no ultrasound was applied, after which the optical power increase plateaued to an average amplification factor of 1.733 ± 0.549 times the control. The increase implies a reduction in light either back-scattered or absorbed within the tissue, which would allow for a greater proportion of incident energy to be delivered to the clinical target, thereby improving procedural efficacy and potentially reducing the severity of detrimental side-effects. Apparatus Lasers Surg. Med. 49:666-674, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Aqueous carrier waveguide in a flow cytometer

    DOEpatents

    Mariella, R.P. Jr.; Engh, G. van den; Northrup, M.A.

    1995-12-12

    The liquid of a flow cytometer itself acts as an optical waveguide, thus transmitting the light to an optical filter/detector combination. This alternative apparatus and method for detecting scattered light in a flow cytometer is provided by a device which views and detects the light trapped within the optical waveguide formed by the flow stream. A fiber optic or other light collecting device is positioned within the flow stream. This provides enormous advantages over the standard light collection technique which uses a microscope objective. The signal-to-noise ratio is greatly increased over that for right-angle-scattered light collected by a microscope objective, and the alignment requirements are simplified. 6 figs.

  10. Increased epidermal laser fluence through simultaneous ultrasonic microporation

    NASA Astrophysics Data System (ADS)

    Whiteside, Paul J. D.; Chininis, Jeff A.; Schellenberg, Mason W.; Qian, Chenxi; Hunt, Heather K.

    2016-03-01

    Lasers have demonstrated widespread applicability in clinical dermatology as minimally invasive instruments that achieve photogenerated responses within tissue. However, before reaching its target, the incident light must first transmit through the surface layer of tissue, which is interspersed with chromophores (e.g. melanin) that preferentially absorb the light and may also generate negative tissue responses. These optical absorbers decrease the efficacy of the procedures. In order to ensure that the target receives a clinically relevant dose, most procedures simply increase the incident energy; however, this tends to exacerbate the negative complications of melanin absorption. Here, we present an alternative solution aimed at increasing epidermal energy uence while mitigating excess absorption by unintended targets. Our technique involves the combination of a waveguide-based contact transmission modality with simultaneous high-frequency ultrasonic pulsation, which alters the optical properties of the tissue through the agglomeration of dissolved gasses into micro-bubbles within the tissue. Doing so effectively creates optically transparent pathways for the light to transmit unobstructed through the tissue, resulting in an increase in forward scattering and a decrease in absorption. To demonstrate this, Q-switched nanosecond-pulsed laser light at 532nm was delivered into pig skin samples using custom glass waveguides clad in titanium and silver. Light transmission through the tissue was measured with a photodiode and integrating sphere for tissue with and without continuous ultrasonic pulsation at 510 kHz. The combination of these techniques has the potential to improve the efficiency of laser procedures while mitigating negative tissue effects caused by undesirable absorption.

  11. Ghost imaging via optical parametric amplification

    NASA Astrophysics Data System (ADS)

    Li, Hong-Guo; Zhang, De-Jian; Xu, De-Qin; Zhao, Qiu-Li; Wang, Sen; Wang, Hai-Bo; Xiong, Jun; Wang, Kaige

    2015-10-01

    We investigate theoretically and experimentally thermal light ghost imaging where the light transmitted through the object as the seed light is amplified by an optical parametric amplifier (OPA). In conventional lens imaging systems with OPA, the spectral bandwidth of OPA dominates the image resolution. Theoretically, we prove that in ghost imaging via optical parametric amplification (GIOPA) the bandwidth of OPA will not affect the image resolution. The experimental results show that for weak seed light the image quality in GIOPA is better than that of conventional ghost imaging. Our work may be valuable in remote sensing with ghost imaging technique, where the light passed through the object is weak after a long-distance propagation.

  12. Optical nanofiber temperature monitoring via double heterodyne detection

    NASA Astrophysics Data System (ADS)

    Anderson, P.; Jalnapurkar, S.; Moiseev, E. S.; Chang, D.; Barclay, P. E.; Lezama, A.; Lvovsky, A. I.

    2018-05-01

    Tapered optical fibers (nanofibers) whose diameters are smaller than the optical wavelength are very fragile and can be easily destroyed if excessively heated by energy dissipated from the transmitted light. We present a technique for monitoring the nanofiber temperature using two-stage heterodyne detection. The phase of the heterodyne output signal is determined by that of the transmitted optical field, which, in turn, depends on the temperature through the refractive index. From the phase data, by numerically solving the heat exchange equations, the temperature distribution along the nanofiber is determined. The technique is applied to the controlled heating of the nanofiber by a laser in order to remove rubidium atoms adsorbed on its surface that substantially degrade its transmission. Almost 90% of the nanofiber's original transmission is recovered.

  13. Optical double-slit particle measuring system

    DOEpatents

    Tichenor, D.A.; Wang, J.C.F.; Hencken, K.R.

    1982-03-25

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3..mu..m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  14. Optical double-slit particle measuring system

    DOEpatents

    Hencken, Kenneth R.; Tichenor, Daniel A.; Wang, James C. F.

    1984-01-01

    A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3 .mu.m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.

  15. Composite resin reinforcement of flared canals using light-transmitting plastic posts.

    PubMed

    Lui, J L

    1994-05-01

    Composite resins have been advocated as a reinforcing build-up material for badly damaged endodontically treated teeth with flared canals. However, the control of an autocuring composite resin is difficult because it polymerizes rapidly within the root canal. While the light-curing composite resins are more user friendly, their polymerization can be a problem deep in the root canal. Light-transmitting plastic posts allow the transmission of light into the root canal and enable intraradicular composite resin reconstitution and reinforcement of weakened roots. At the same time, the light-transmitting plastic post forms an optimal post canal in the rehabilitated root and can accurately fit a matching retentive final post. These light-transmitting posts are a useful addition to the dental armamentarium.

  16. Development of electronic cinema projectors

    NASA Astrophysics Data System (ADS)

    Glenn, William E.

    2001-03-01

    All of the components for the electronic cinema are now commercially available. Sony has a high definition progressively scanned 24 frame per second electronic cinema camera. This can be recorded digitally on tape or film on hard drives in RAID recorders. Much of the post production processing is now done digitally by scanning film, processing it digitally, and recording it on film for release. Fiber links and satellites can transmit cinema program material to theaters in real time. RAID or tape recorders can play programs for viewing at a much lower cost than storage on film. Two companies now have electronic cinema projectors on the market. Of all of the components, the electronic cinema projector is the most challenging. Achieving the resolution, light, output, contrast ratio, and color rendition all at the same time without visible artifacts is a difficult task. Film itself is, of course, a form of light-valve. However, electronically modulated light uses other techniques rather than changes in density to control the light. The optical techniques that have been the basis for many electronic light-valves have been under development for over 100 years. Many of these techniques are based on optical diffraction to modulate the light. This paper will trace the history of these techniques and show how they may be extended to produce electronic cinema projectors in the future.

  17. Diffusing Wave Spectroscopy Used to Study Foams

    NASA Technical Reports Server (NTRS)

    Zimmerli, Gregory A.; Durian, Douglas J.

    2000-01-01

    The white appearance of familiar objects such as clouds, snow, milk, or foam is due to the random scattering of light by the sample. As we all know, pure water is clear and easily passes a beam of light. However, tiny water droplets, such as those in a cloud, scatter light because the air and water droplet have different indexes of refraction. When many droplets, or scattering sites, are present, the incident light is scattered in random directions and the sample takes on a milky white appearance. In a glass of milk, the scattering is due to small colloidal particles. The white appearance of shaving cream, or foam, is due to the scattering of light at the water-bubble interface. Diffusing wave spectroscopy (DWS) is a laser light-scattering technique used to noninvasively probe the particle dynamics in systems that strongly scatter light. The technique takes advantage of the diffuse nature of light, which is reflected or transmitted from samples such as foams, dense colloidal suspensions (such as paint and milk), emulsions, liquid crystals, sandpiles, and even biological tissues.

  18. A review on channel models in free space optical communication systems

    NASA Astrophysics Data System (ADS)

    Anbarasi, K.; Hemanth, C.; Sangeetha, R. G.

    2017-12-01

    Free Space Optical communication (FSO) is a wireless communication technology which uses light to transmit the data in free space. FSO has advantages like unlicensed spectrum and higher bandwidth. In this paper FSO system merits and demerits, challenges in FSO, and various channel models are discussed. To mitigate the turbulence in FSO the mitigation techniques like relaying, diversity schemes and adopting different modulation techniques used in different channels are discussed and its performance comparison is given.

  19. Condenser-free contrast methods for transmitted-light microscopy

    PubMed Central

    WEBB, K F

    2015-01-01

    Phase contrast microscopy allows the study of highly transparent yet detail-rich specimens by producing intensity contrast from phase objects within the sample. Presented here is a generalized phase contrast illumination schema in which condenser optics are entirely abrogated, yielding a condenser-free yet highly effective method of obtaining phase contrast in transmitted-light microscopy. A ring of light emitting diodes (LEDs) is positioned within the light-path such that observation of the objective back focal plane places the illuminating ring in appropriate conjunction with the phase ring. It is demonstrated that true Zernike phase contrast is obtained, whose geometry can be flexibly manipulated to provide an arbitrary working distance between illuminator and sample. Condenser-free phase contrast is demonstrated across a range of magnifications (4–100×), numerical apertures (0.13–1.65NA) and conventional phase positions. Also demonstrated is condenser-free darkfield microscopy as well as combinatorial contrast including Rheinberg illumination and simultaneous, colour-contrasted, brightfield, darkfield and Zernike phase contrast. By providing enhanced and arbitrary working space above the preparation, a range of concurrent imaging and electrophysiological techniques will be technically facilitated. Condenser-free phase contrast is demonstrated in conjunction with scanning ion conductance microscopy (SICM), using a notched ring to admit the scanned probe. The compact, versatile LED illumination schema will further lend itself to novel next-generation transmitted-light microscopy designs. The condenser-free illumination method, using rings of independent or radially-scanned emitters, may be exploited in future in other electromagnetic wavebands, including X-rays or the infrared. PMID:25226859

  20. Comparative cost assessment of the Kato-Katz and FLOTAC techniques for soil-transmitted helminth diagnosis in epidemiological surveys

    PubMed Central

    2010-01-01

    Background The Kato-Katz technique is widely used for the diagnosis of soil-transmitted helminthiasis in epidemiological surveys and is believed to be an inexpensive method. The FLOTAC technique shows a higher sensitivity for the diagnosis of light-intensity soil-transmitted helminth infections but is reported to be more complex and expensive. We assessed the costs related to the collection, processing and microscopic examination of stool samples using the Kato-Katz and FLOTAC techniques in an epidemiological survey carried out in Zanzibar, Tanzania. Methods We measured the time for the collection of a single stool specimen in the field, transfer to a laboratory, preparation and microscopic examination using standard protocols for the Kato-Katz and FLOTAC techniques. Salaries of health workers, life expectancy and asset costs of materials, and infrastructure costs were determined. The average cost for a single or duplicate Kato-Katz thick smears and the FLOTAC dual or double technique were calculated. Results The average time needed to collect a stool specimen and perform a single or duplicate Kato-Katz thick smears or the FLOTAC dual or double technique was 20 min and 34 sec (20:34 min), 27:21 min, 28:14 min and 36:44 min, respectively. The total costs for a single and duplicate Kato-Katz thick smears were US$ 1.73 and US$ 2.06, respectively, and for the FLOTAC double and dual technique US$ 2.35 and US$ 2.83, respectively. Salaries impacted most on the total costs of either method. Conclusions The time and cost for soil-transmitted helminth diagnosis using either the Kato-Katz or FLOTAC method in epidemiological surveys are considerable. Our results can help to guide healthcare decision makers and scientists in budget planning and funding for epidemiological surveys, anthelminthic drug efficacy trials and monitoring of control interventions. PMID:20707931

  1. Ultrafast optical technique for the characterization of altered materials

    DOEpatents

    Maris, H.J.

    1998-01-06

    Disclosed herein is a method and a system for non-destructively examining a semiconductor sample having at least one localized region underlying a surface through into which a selected chemical species has been implanted or diffused. A first step induces at least one transient time-varying change in optical constants of the sample at a location at or near to a surface of the sample. A second step measures a response of the sample to an optical probe beam, either pulsed or continuous wave, at least during a time that the optical constants are varying. A third step associates the measured response with at least one of chemical species concentration, chemical species type, implant energy, a presence or absence of an introduced chemical species region at the location, and a presence or absence of implant-related damage. The method and apparatus in accordance with this invention can be employed in conjunction with a measurement of one or more of the following effects arising from a time-dependent change in the optical constants of the sample due to the application of at least one pump pulse: (a) a change in reflected intensity; (b) a change in transmitted intensity; (c) a change in a polarization state of the reflected and/or transmitted light; (d) a change in the optical phase of the reflected and/or transmitted light; (e) a change in direction of the reflected and/or transmitted light; and (f) a change in optical path length between the sample`s surface and a detector. 22 figs.

  2. Ultrafast optical technique for the characterization of altered materials

    DOEpatents

    Maris, Humphrey J.

    1998-01-01

    Disclosed herein is a method and a system for non-destructively examining a semiconductor sample (30) having at least one localized region underlying a surface (30a) through into which a selected chemical species has been implanted or diffused. A first step induces at least one transient time-varying change in optical constants of the sample at a location at or near to a surface of the sample. A second step measures a response of the sample to an optical probe beam, either pulsed or continuous wave, at least during a time that the optical constants are varying. A third step associates the measured response with at least one of chemical species concentration, chemical species type, implant energy, a presence or absence of an introduced chemical species region at the location, and a presence or absence of implant-related damage. The method and apparatus in accordance with this invention can be employed in conjunction with a measurement of one or more of the following effects arising from a time-dependent change in the optical constants of the sample due to the application of at least one pump pulse: (a) a change in reflected intensity; (b) a change in transmitted intensity; (c) a change in a polarization state of the reflected and/or transmitted light; (d) a change in the optical phase of the reflected and/or transmitted light; (e) a change in direction of the reflected and/or transmitted light; and (f) a change in optical path length between the sample's surface and a detector.

  3. Laser-induced micro-plasmas in air for incoherent broadband cavity-enhanced absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Ruth, Albert; Dixneuf, Sophie; Orphal, Johannes

    2016-04-01

    Incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) is an experimentally straightforward absorption method where the intensity of light transmitted by an optically stable (high finesse) cavity is measured. The technique is realized using broadband incoherent sources of radiation and therefore the amount of light transmitted by a cavity consisting of high reflectance mirrors (typically R > 99.9%) can be low. In order to find an alternative to having an incoherent light source outside the cavity, an experiment was devised, where a laser-induced plasma in ambient air was generated inside a quasi-confocal cavity by a high-power femtosecond laser. The emission from the laser-induced plasma was utilized as pulsed broadband light source. The time-dependent spectra of the light leaking from the cavity were compared with those of the laser-induced plasma emission without the cavity. It was found that the light emission was sustained by the cavity despite the initially large optical losses caused by the laser-induced plasma in the cavity. The light sustained by the cavity was used to measure part of the S1 ← S0 absorption spectrum of gaseous azulene at its vapour pressure at room temperature in ambient air, as well as the strongly forbidden γ-band in molecular oxygen (b1Σ(2,0) ← X3Σ(0,0)).

  4. Nanomaterial-Enabled Neural Stimulation

    PubMed Central

    Wang, Yongchen; Guo, Liang

    2016-01-01

    Neural stimulation is a critical technique in treating neurological diseases and investigating brain functions. Traditional electrical stimulation uses electrodes to directly create intervening electric fields in the immediate vicinity of neural tissues. Second-generation stimulation techniques directly use light, magnetic fields or ultrasound in a non-contact manner. An emerging generation of non- or minimally invasive neural stimulation techniques is enabled by nanotechnology to achieve a high spatial resolution and cell-type specificity. In these techniques, a nanomaterial converts a remotely transmitted primary stimulus such as a light, magnetic or ultrasonic signal to a localized secondary stimulus such as an electric field or heat to stimulate neurons. The ease of surface modification and bio-conjugation of nanomaterials facilitates cell-type-specific targeting, designated placement and highly localized membrane activation. This review focuses on nanomaterial-enabled neural stimulation techniques primarily involving opto-electric, opto-thermal, magneto-electric, magneto-thermal and acousto-electric transduction mechanisms. Stimulation techniques based on other possible transduction schemes and general consideration for these emerging neurotechnologies are also discussed. PMID:27013938

  5. Transmitting and reflecting diffuser. [for ultraviolet light

    NASA Technical Reports Server (NTRS)

    Keafer, L. S., Jr.; Burcher, E. E.; Kopia, L. P. (Inventor)

    1973-01-01

    A near-Lambertian diffuser is described which transmits and reflects ultraviolet light. An ultraviolet grade fused silica substrate is coated with vaporized fuse silica. The coating thickness is controlled, one thickness causing ultraviolet light to diffuse and another thickness causing ultraviolet light to reflect a near Lambertian pattern.

  6. Determining light requirements of groundcover plants from subtropical natural forest using hemispherical photography

    NASA Astrophysics Data System (ADS)

    Zhang, Yi; Zhong, Yonglin; Xu, Mingfeng; Su, Zhiyao

    2017-01-01

    In order to determine light requirements of indigenous groundcover plants for potential use in urban landscaping, we conducted a plant census in Yinpingshan Nature Reserve, Dongguan, China, and measured canopy structure and understory light regimes using hemispherical photography. We found that canopy openness, transmitted direct solar radiation, and transmitted diffuse solar radiation exhibited highly significant spatial heterogeneity. Species composition and diversity of groundcover plants were highly dependent on canopy structure and understory light condition. Greater diversity and more stems of groundcover plants were associated with greater canopy openness and understory radiation in most cases. Highly significant differences in species composition were detected along canopy openness, transmitted direct solar radiation, and transmitted diffuse solar radiation gradients, respectively. We also detected indicator species for specific understory light regimes, which will provide useful information when applying such species in urban greening under various light environments.

  7. Circularly polarized light to study linear magneto-optics for ferrofluids: θ-scan technique

    NASA Astrophysics Data System (ADS)

    Meng, Xiangshen; Huang, Yan; He, Zhenghong; Lin, Yueqiang; Liu, Xiaodong; Li, Decai; Li, Jian; Qiu, Xiaoyan

    2018-06-01

    Circularly polarized light can be divided into two vertically linearly polarized light beams with  ±π/2 phase differences. In the presence of an external magnetic field, when circularly polarized light travels through a ferrofluid film, whose thickness is no more than that of λ/4 plate, magneto-optical, magnetic birefringence and dichroism effects cause the transmitted light to behave as elliptically polarized light. Using angular scan by a continuously rotating polarizer as analyzer, the angular (θ) distribution curve of relative intensity (T) corresponding to elliptically polarized light can be measured. From the T  ‑  θ curve having ellipsometry, the parameters such as the ratio of short to long axis, and angular orientation of the long axis to the vertical field direction can be obtained. Thus, magnetic birefringence and dichroism can be probed simultaneously by measuring magneto-optical, positive or negative birefringence and dichroism features from the transmission mode. The proposed method is called θ-scan technique, and can accurately determine sample stability, magnetic field direction, and cancel intrinsic light source ellipticity. This study may be helpful to further research done to ferrofluids and other similar colloidal samples with anisotropic optics.

  8. 47 CFR 17.57 - Report of radio transmitting antenna construction, alteration, and/or removal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Report of radio transmitting antenna... COMMISSION GENERAL CONSTRUCTION, MARKING, AND LIGHTING OF ANTENNA STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.57 Report of radio transmitting antenna construction...

  9. 47 CFR 17.57 - Report of radio transmitting antenna construction, alteration, and/or removal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Report of radio transmitting antenna... COMMISSION GENERAL CONSTRUCTION, MARKING, AND LIGHTING OF ANTENNA STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.57 Report of radio transmitting antenna construction...

  10. Miniature LED endoilluminators for vitreoretinal surgery

    NASA Astrophysics Data System (ADS)

    Hessling, M.; Koelbl, P. S.; Lingenfelder, C.; Koch, F.

    2015-07-01

    Two innovative approaches for intraocular illumination during vitreoretinal surgery by application of white LEDs are being developed. Both techniques are less harmful to the patient, more convenient for the surgeon and smaller and cheaper compared to conventional illumination by Xenon light sources and optical fibers. These two novel approaches are: I) The miniature LED chandelier endoilluminator consisting of a single white LED with a "light probe" on top of the LED housing that fits in a small incision in the wall of the eye. II) The alternative transscleral LED endoilluminator is integrated into an eye speculum that presses the flat LED top against the eye. The intraocular space is only illuminated by light transmitted through the sclera. In contrast to conventional illumination techniques for vitreoretinal surgery no incision is necessary. Both approaches are evaluated with regard to potential photochemical and thermal risks for the patient's retina and they are tested on porcine eyes.

  11. Probing metamaterials with structured light

    DOE PAGES

    Xu, Yun; Sun, Jingbo; Walasik, Wiktor; ...

    2016-11-03

    Photonic metamaterials and metasurfaces are nanostructured optical materials engineered to enable properties that have not been found in nature. Optical characterization of these structures is a challenging task. We report a reliable technique that is particularly useful for characterization of phase properties introduced by small and spatially inhomogeneous samples of metamaterials and metasurfaces. The proposed structured light, or vortex based interferometric method is used to directly visualize phase changes introduced by subwavelength-thick nanostructures. In order to demonstrate the efficiency of the proposed technique, we designed and fabricated several metasurface samples consisting of metal nano-antennas introducing different phase shifts and experimentallymore » measured phase shifts of the transmitted light. The experimental results are in good agreement with numerical simulations and with the designed properties of the antenna arrays. Finally, due to the presence of the singularity in the vortex beam, one of the potential applications of the proposed approach based on structured light is step-by-step probing of small fractions of the micro-scale samples or images.« less

  12. Analysis of the Light Transmission Ability of Reinforcing Glass Fibers Used in Polymer Composites.

    PubMed

    Hegedűs, Gergely; Sarkadi, Tamás; Czigány, Tibor

    2017-06-10

    This goal of our research was to show that E-glass fiber bundles used for reinforcing composites can be enabled to transmit light in a common resin without any special preparation (without removing the sizing). The power of the transmitted light was measured and the attenuation coefficient, which characterizes the fiber bundle, was determined. Although the attenuation coefficient depends on temperature and the wavelength of the light, it is independent of the power of incident light, the quality of coupling, and the length of the specimen. The refractive index of commercially available transparent resins was measured and it was proved that a resin with a refractive index lower than that of the fiber can be used to make a composite whose fibers are capable of transmitting light. The effects of temperature, compression of the fibers, and the shape of fiber ends on the power of transmitted light were examined. The measurement of emitted light can provide information about the health of the fibers. This can be the basis of a simple health monitoring system in the case of general-purpose composite structures.

  13. Analysis of the Light Transmission Ability of Reinforcing Glass Fibers Used in Polymer Composites

    PubMed Central

    Hegedűs, Gergely; Sarkadi, Tamás; Czigány, Tibor

    2017-01-01

    This goal of our research was to show that E-glass fiber bundles used for reinforcing composites can be enabled to transmit light in a common resin without any special preparation (without removing the sizing). The power of the transmitted light was measured and the attenuation coefficient, which characterizes the fiber bundle, was determined. Although the attenuation coefficient depends on temperature and the wavelength of the light, it is independent of the power of incident light, the quality of coupling, and the length of the specimen. The refractive index of commercially available transparent resins was measured and it was proved that a resin with a refractive index lower than that of the fiber can be used to make a composite whose fibers are capable of transmitting light. The effects of temperature, compression of the fibers, and the shape of fiber ends on the power of transmitted light were examined. The measurement of emitted light can provide information about the health of the fibers. This can be the basis of a simple health monitoring system in the case of general-purpose composite structures. PMID:28772996

  14. Optimization of subcutaneous vein contrast enhancement

    NASA Astrophysics Data System (ADS)

    Zeman, Herbert D.; Lovhoiden, Gunnar; Deshmukh, Harshal

    2000-05-01

    A technique for enhancing the contrast of subcutaneous veins has been demonstrated. This techniques uses a near IR light source and one or more IR sensitive CCD TV cameras to produce a contrast enhanced image of the subcutaneous veins. This video image of the veins is projected back onto the patient's skin using a n LCD video projector. The use of an IR transmitting filter in front of the video cameras prevents any positive feedback from the visible light from the video projector from causing instabilities in the projected image. The demonstration contrast enhancing illuminator has been tested on adults and children, both Caucasian and African-American, and it enhances veins quite well in all cases. The most difficult cases are those where significant deposits of subcutaneous fat are present which make the veins invisible under normal room illumination. Recent attempts to see through fat using different IR wavelength bands and both linearly and circularly polarized light were unsuccessful. The key to seeing through fat turns out to be a very diffuse source of RI light. Results on adult and pediatric subjects are shown with this new IR light source.

  15. Fiber optic probe for light scattering measurements

    DOEpatents

    Nave, Stanley E.; Livingston, Ronald R.; Prather, William S.

    1995-01-01

    A fiber optic probe and a method for using the probe for light scattering analyses of a sample. The probe includes a probe body with an inlet for admitting a sample into an interior sample chamber, a first optical fiber for transmitting light from a source into the chamber, and a second optical fiber for transmitting light to a detector such as a spectrophotometer. The interior surface of the probe carries a coating that substantially prevents non-scattered light from reaching the second fiber. The probe is placed in a region where the presence and concentration of an analyte of interest are to be detected, and a sample is admitted into the chamber. Exciting light is transmitted into the sample chamber by the first fiber, where the light interacts with the sample to produce Raman-scattered light. At least some of the Raman-scattered light is received by the second fiber and transmitted to the detector for analysis. Two Raman spectra are measured, at different pressures. The first spectrum is subtracted from the second to remove background effects, and the resulting sample Raman spectrum is compared to a set of stored library spectra to determine the presence and concentration of the analyte.

  16. Fiber optic probe for light scattering measurements

    DOEpatents

    Nave, S.E.; Livingston, R.R.; Prather, W.S.

    1993-01-01

    This invention is comprised of a fiber optic probe and a method for using the probe for light scattering analyses of a sample. The probe includes a probe body with an inlet for admitting a sample into an interior sample chamber, a first optical fiber for transmitting light from a source into the chamber, and a second optical fiber for transmitting light to a detector such as a spectrophotometer. The interior surface of the probe carries a coating that substantially prevents non-scattered light from reaching the second fiber. The probe is placed in a region where the presence and concentration of an analyte of interest are to be detected, and a sample is admitted into the chamber. Exciting light is transmitted into the sample chamber by the first fiber, where the light interacts with the sample to produce Raman-scattered light. At least some of the Raman- scattered light is received by the second fiber and transmitted to the detector for analysis. Two Raman spectra are measured, at different pressures. The first spectrum is subtracted from the second to remove background effects, and the resulting sample Raman spectrum is compared to a set of stored library spectra to determine the presence and concentration of the analyte.

  17. Real-time high-resolution measurement of collagen alignment in dynamically loaded soft tissue.

    PubMed

    York, Timothy; Kahan, Lindsey; Lake, Spencer P; Gruev, Viktor

    2014-06-01

    A technique for creating maps of the direction and strength of fiber alignment in collagenous soft tissues is presented. The method uses a division of focal plane polarimeter to measure circularly polarized light transmitted through the tissue. The architecture of the sensor allows measurement of the retardance and fiber alignment at the full frame rate of the sensor without any moving optics. The technique compares favorably to the standard method of using a rotating polarizer. How the new technique enables real-time capture of the full angular spread of fiber alignment and retardance under various cyclic loading conditions is illustrated.

  18. Method and apparatus for optical temperature measurement

    DOEpatents

    O'Rourke, P.E.; Livingston, R.R.; Prather, W.S.

    1994-09-20

    A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe are disclosed. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped borosilicate glass, accurate to [+-]0.5 C over an operating temperature range of about [minus]196 C to 400 C; and a mixture of D[sub 2]O and H[sub 2]O, accurate to [+-]0.1 C over an operating range of about 5 C to 90 C. 13 figs.

  19. Method and apparatus for optical temperature measurement

    DOEpatents

    O'Rourke, Patrick E.; Livingston, Ronald R.; Prather, William S.

    1994-01-01

    A temperature probe and a method for using said probe for temperature measurements based on changes in light absorption by the probe. The probe comprises a first and a second optical fiber that carry light to and from the probe, and a temperature sensor material, the absorbance of which changes with temperature, through which the light is directed. Light is directed through the first optical fiber, passes through the temperature sensor material, and is transmitted by a second optical fiber from the material to a detector. Temperature-dependent and temperature-independent factors are derived from measurements of the transmitted light intensity. For each sensor material, the temperature T is a function of the ratio, R, of these factors. The temperature function f(R) is found by applying standard data analysis techniques to plots of T versus R at a series of known temperatures. For a sensor having a known temperature function f(R) and known characteristic and temperature-dependent factors, the temperature can be computed from a measurement of R. Suitable sensor materials include neodymium-doped boresilicate glass, accurate to .+-.0.5.degree. C. over an operating temperature range of about -196.degree. C. to 400.degree. C.; and a mixture of D.sub.2 O and H.sub.2 O, accurate to .+-.0.1.degree. C. over an operating range of about 5.degree. C. to 90.degree. C.

  20. Low-complexity peak-to-average power ratio reduction scheme for flip-orthogonal frequency division multiplexing visible light communication system based on μ-law mapping

    NASA Astrophysics Data System (ADS)

    Wang, Jianping; Zhang, Peiran; Lu, Huimin; Feng, LiFang

    2017-06-01

    An orthogonal frequency division multiplexing (OFDM) technique called flipped OFDM (flip-OFDM) is apposite for a visible light communication system that needs the transmitted signal to be real and positive. Flip-OFDM uses two consecutive OFDM subframes to transmit the positive and negative parts of the signal. However, peak-to-average power ratio (PAPR) for flip-OFDM is increased tremendously due to the low value of total average power that arises from many zero values in both the positive and flipped frames. We first analyze the performance of flip-OFDM and perform a comparison with the conventional DC-biased OFDM (DCO-OFDM); then we propose a flip-OFDM scheme combined with μ-law mapping to reduce the high PAPR. The simulation results show that the PAPR of the system is reduced about 17.2 and 5.9 dB when compared with the normal flip-OFDM and DCO-OFDM signals, respectively.

  1. Apparatus and method for measuring the thickness of a semiconductor wafer

    DOEpatents

    Ciszek, Theodoer F.

    1995-01-01

    Apparatus for measuring thicknesses of semiconductor wafers, comprising: housing means for supporting a wafer in a light-tight environment; a light source mounted to the housing at one side of the wafer to emit light of a predetermined wavelength to normally impinge the wafer; a light detector supported at a predetermined distance from a side of the wafer opposite the side on which a light source impinges and adapted to receive light transmitted through the wafer; and means for measuring the transmitted light.

  2. Optical backscatter probe for sensing particulate in a combustion gas stream

    DOEpatents

    Parks, James E; Partridge, William P

    2013-05-28

    A system for sensing particulate in a combustion gas stream is disclosed. The system transmits light into a combustion gas stream, and thereafter detects a portion of the transmitted light as scattered light in an amount corresponding to the amount of particulates in the emissions. Purge gas may be supplied adjacent the light supply and the detector to reduce particles in the emissions from coating or otherwise compromising the transmission of light into the emissions and recovery of scattered light from the emissions.

  3. Boundary Layer Measurements in a Supersonic Wind Tunnel Using Doppler Global Velocimetry

    NASA Technical Reports Server (NTRS)

    Meyers, James F.; Lee, Joseph W.; Cavone, Angelo A.

    2010-01-01

    A modified Doppler Global Velocimeter (DGV) was developed to measure the velocity within the boundary layer above a flat plate in a supersonic flow. Classic laser velocimetry (LV) approaches could not be used since the model surface was composed of a glass-ceramic insulator in support of heat-transfer measurements. Since surface flare limited the use of external LV techniques and windows placed in the model would change the heat transfer characteristics of the flat plate, a novel approach was developed. The input laser beam was divided into nine equal power beams and each transmitted through optical fibers to a small cavity within the model. The beams were then directed through 1.6-mm diameter orifices to form a series of orthogonal beams emitted from the model and aligned with the tunnel centerline to approximate a laser light sheet. Scattered light from 0.1-micron diameter water condensation ice crystals was collected by four 5-mm diameter lenses and transmitted by their respective optical fiber bundles to terminate at the image plane of a standard two-camera DGV receiver. Flow measurements were made over a range from 0.5-mm above the surface to the freestream at Mach 3.51 in steady state and heat pulse injected flows. This technique provides a unique option for measuring boundary layers in supersonic flows where seeding the flow is problematic or where the experimental apparatus does not provide the optical access required by other techniques.

  4. Apparatus and method for measuring the thickness of a semiconductor wafer

    DOEpatents

    Ciszek, T.F.

    1995-03-07

    Apparatus for measuring thicknesses of semiconductor wafers is discussed, comprising: housing means for supporting a wafer in a light-tight environment; a light source mounted to the housing at one side of the wafer to emit light of a predetermined wavelength to normally impinge the wafer; a light detector supported at a predetermined distance from a side of the wafer opposite the side on which a light source impinges and adapted to receive light transmitted through the wafer; and means for measuring the transmitted light. 4 figs.

  5. Light redirecting system using sine-wave based panels for dense urban areas

    NASA Astrophysics Data System (ADS)

    Mohamed, Mohamed W. N.; Mashaly, Islam A.; Mohamed, Osama N.; El-Henawy, Sally I.; Galal, Ola; Taha, Iman; Nassar, Khaled; Safwat, Amr M. E.

    2014-09-01

    Cities and towns around the world are becoming more condensed due to the shrinking amount of buildable areas, which significantly reduces the amount of light that occupants have access to. This lack of natural lighting results in health, safety and quality of life degradation. This paper presents a new technique of transmitting sunlight downward into narrow alleys and streets, by using a daylighting guiding acrylic panel that is capable of changing the direction and distribution of the incident light. The core of the proposed daylight guidance system is made up of light transmission panels with high quality. The corrugations have sine wave shaped cross-section so that the panel functions as an optical diffuser perpendicular to the direction of sunlight propagation. The day lighting system consists of the corrugated panels and a lattice frame, which supports the panel. The proposed system is to be mounted on the building roof facing the sun so as to redirect the incident sunlight downward into the narrow alleys or streets. Since building sizes and orientations are different the frame is arranged such that substantially deep light penetration and high luminance level can be achieved. Simulation results show that the proposed panel improves the illuminance values by more than 200% and 400% in autumn and winter, respectively, provides fan-out angle that exceeds 80° for certain solar altitudes and the transmitted power percentage varies from 40% to 90% as the solar altitude varies from 10° to 80°. Experimental results are in a good agreement with the simulations.

  6. A versatile setup using femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Yujie, E-mail: styojm@physics.tamu.edu; Voronine, Dmitri V.; Sokolov, Alexei V.

    2015-08-15

    We report a versatile setup based on the femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman scattering. The setup uses a femtosecond Ti:Sapphire oscillator source and a folded 4f pulse shaper, in which the pulse shaping is carried out through conventional optical elements and does not require a spatial light modulator. Our setup is simple in alignment, and can be easily switched between the collinear single-beam and the noncollinear two-beam configurations. We demonstrate the capability for investigating both transparent and highly scattering samples by detecting transmitted and reflected signals, respectively.

  7. Theoretical Investigation of Tunable Goos-Hänchen Shifts in a Four-Level Quantum System

    NASA Astrophysics Data System (ADS)

    Jafarzadeh, Hossein; Payravi, Mohammad

    2018-05-01

    Goos-Hänchen (GH) shifts in the reflected and transmitted light have been discussed in a cavity with four-level quantum system. It is realized that the refraction index of intracavity medium can be negative by manipulating the external coherent laser fields. For the negative refraction index of intracavity medium, the GH shifts of reflected and transmitted light beams have been analyzed in a parametric condition. It is found that due to modulation of laser signals and relative phase between applied fields, large and tunable GH shifts in reflected and transmitted light beams can be obtained.

  8. Quantitative 3D model of light transmittance through translucent rocks applied to the hypolithic microbial community.

    PubMed

    Jolitz, Rebecca D; McKay, Christopher P

    2013-07-01

    In extreme desert environments, photosynthetic microorganisms often live on the buried undersides of translucent rocks. Computing the light level reaching these locations requires 3D modeling of a finite rock. We report on Monte Carlo calculations of skylight and sunlight transmission through a partially buried flat cylindrical rock using one billion photons per simulation. Transmitted light level drops inversely with increasing rock opacity, as expected for purely scattering media. For a half-buried rock with an extinction coefficient of 0.1 cm(-1) (opacity of 0.2), transmission at the bottom is 64 % for sunlight at a solar zenith angle of 60° and 82 % for skylight. Transmitted light level increases slowly with increasing scattering asymmetry factor of the rock independent of illumination or depth buried. Transmitted sunlight at zenith through a thick half-buried rock (opacity of 0.6) is six times brighter at the bottom than the subsurface sides. Skylight transmits equally to the subsurface sides and bottom. When the sun is not straight overhead, the sunward side of the rock is brighter than the underside of the rock. Compared to the sunlight transmitted to the bottom, transmitted sunlight inclined at 60° is 24 times brighter at the subsurface side towards the sun and 14 times brighter at the subsurface side 70° away from the sun. Transmitted sunlight emitted from zenith and skylight is uniformly bright at the bottom regardless of how deeply the rock is buried. Sunlight not at zenith transmits preferentially to the sunward bottom edge depending on the depth the rock is buried.

  9. Microparticle analysis system and method

    NASA Technical Reports Server (NTRS)

    Morrison, Dennis R. (Inventor)

    2007-01-01

    A device for analyzing microparticles is provided which includes a chamber with an inlet and an outlet for respectively introducing and dispensing a flowing fluid comprising microparticles, a light source for providing light through the chamber and a photometer for measuring the intensity of light transmitted through individual microparticles. The device further includes an imaging system for acquiring images of the fluid. In some cases, the device may be configured to identify and determine a quantity of the microparticles within the fluid. Consequently, a method for identifying and tracking microparticles in motion is contemplated herein. The method involves flowing a fluid comprising microparticles in laminar motion through a chamber, transmitting light through the fluid, measuring the intensities of the light transmitted through the microparticles, imaging the fluid a plurality of times and comparing at least some of the intensities of light between different images of the fluid.

  10. The rapid determination of fat and protein content in fresh raw milk using the laser light scattering technology

    NASA Astrophysics Data System (ADS)

    Xin, Qi; Zhi Ling, Hou; Jian Long, Tian; Zhu, Yu

    2006-08-01

    The aim was to develop a simple and rapid method for determination of fat and protein content in milk. Based on the laser light scattering theory, the ratio of the scattered light (at 90±0.05° scattering angles) intensity to the transmitted light intensity, which is called scattered-transmitted-ratio method, is adopted as the optical parameter representing the milk fat content and the protein content. In this way, the influence of the fluctuation of the power of the light source is eliminated and the accuracy of determination is improved accordingly. The system we use is real-time and can satisfy the challenging requirements of dairy farming. Results of this study indicate the feasibility of using this technology for fresh milk fat and protein analysis. The fat contents and protein contents of 50 milk samples determined by this method were consistent with the values obtained by the reference methods based on Rose-Gottlieb method and Kjeldahl determination of N method. In this paper, the operating principle of the instrument is introduced and the influence of the environmental conditions, such as the homogenization pressure and homogenization temperature, etc. on the result of the test is analyzed. Through data analysis, the concrete schemes for testing the fat using the curve fitting and testing the protein using the surface fitting technique are determined. Finally, the difference from the reference values of the test is discussed.

  11. Cavity electromagnetically induced transparency with Rydberg atoms

    NASA Astrophysics Data System (ADS)

    Bakar Ali, Abu; Ziauddin

    2018-02-01

    Cavity electromagnetically induced transparency (EIT) is revisited via the input probe field intensity. A strongly interacting Rydberg atomic medium ensemble is considered in a cavity, where atoms behave as superatoms (SAs) under the dipole blockade mechanism. Each atom in the strongly interacting Rydberg atomic medium (87 Rb) follows a three-level cascade atomic configuration. A strong control and weak probe field are employed in the cavity with the ensemble of Rydberg atoms. The features of the reflected and transmitted probe light are studied under the influence of the input probe field intensity. A transparency peak (cavity EIT) is revealed at a resonance condition for small values of input probe field intensity. The manipulation of the cavity EIT is reported by tuning the strength of the input probe field intensity. Further, the phase and group delay of the transmitted and reflected probe light are studied. It is found that group delay and phase in the reflected light are negative, while for the transmitted light they are positive. The magnitude control of group delay in the transmitted and reflected light is investigated via the input probe field intensity.

  12. Fiber optic probe having fibers with endfaces formed for improved coupling efficiency and method using same

    DOEpatents

    O`Rourke, P.E.; Livingston, R.R.

    1995-03-28

    A fiber optic probe is disclosed for detecting scattered light, with transmitting and receiving fibers having slanted ends and bundled together to form a bevel within the tip of the probe. The probe comprises a housing with a transparent window across its tip for protecting the transmitting and receiving fibers held therein. The endfaces of the fibers are slanted, by cutting, polishing and the like, so that they lie in a plane that is not perpendicular to the longitudinal axis of the respective fiber. The fibers are held in the tip of the probe using an epoxy and oriented so that lines normal to the slanted endfaces are divergent with respect to one another. The epoxy, which is positioned substantially between the transmitting and receiving fibers, is tapered so that the transmitting fiber, the epoxy and the receiving fiber form a bevel of not more than 20 degrees. The angled fiber endfaces cause directing of the light cones toward each other, resulting in improved light coupling efficiency. A light absorber, such as carbon black, is contained in the epoxy to reduce crosstalk between the transmitting and receiving fibers. 3 figures.

  13. Fiber optic probe having fibers with endfaces formed for improved coupling efficiency and method using same

    DOEpatents

    O'Rourke, Patrick E.; Livingston, Ronald R.

    1995-01-01

    A fiber optic probe for detecting scattered light, with transmitting and receiving fibers having slanted ends and bundled together to form a bevel within the tip of the probe. The probe comprises a housing with a transparent window across its tip for protecting the transmitting and receiving fibers held therein. The endfaces of the fibers are slanted, by cutting, polishing and the like, so that they lie in a plane that is not perpendicular to the longitudinal axis of the respective fiber. The fibers are held in the tip of the probe using an epoxy and oriented so that lines normal to the slanted endfaces are divergent with respect to one another. The epoxy, which is positioned substantially between the transmitting and receiving fibers, is tapered so that the transmitting fiber, the epoxy and the receiving fiber form a bevel of not more than 20 degrees. The angled fiber endfaces cause directing of the light cones toward each other, resulting in improved light coupling efficiency. A light absorber, such as carbon black, is contained in the epoxy to reduce crosstalk between the transmitting and receiving fibers.

  14. A MISO UCA Beamforming Dimmable LED System for Indoor Positioning

    PubMed Central

    Taparugssanagorn, Attaphongse; Siwamogsatham, Siwaruk; Pomalaza-Ráez, Carlos

    2014-01-01

    The use of a multiple input single output (MISO) transmit beamforming system using dimmable light emitting arrays (LEAs) in the form of a uniform circular array (UCA) of transmitters is proposed in this paper. With this technique, visible light communications between a transmitter and a receiver (LED reader) can be achieved with excellent performance and the receiver's position can be estimated. A hexagonal lattice alignment of LED transmitters is deployed to reduce the coverage holes and the areas of overlapping radiation. As a result, the accuracy of the position estimation is better than when using a typical rectangular grid alignment. The dimming control is done with pulse width modulation (PWM) to obtain an optimal closed loop beamforming and minimum energy consumption with acceptable lighting. PMID:24481234

  15. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    PubMed

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  16. Method for Non-Invasive Determination of Chemical Properties of Aqueous Solutions

    NASA Technical Reports Server (NTRS)

    Jones, Alan (Inventor); Thomas, Nathan A. (Inventor); Todd, Paul W. (Inventor)

    2016-01-01

    A method for non-invasively determining a chemical property of an aqueous solution is provided. The method provides the steps of providing a colored solute having a light absorbance spectrum and transmitting light through the colored solute at two different wavelengths. The method further provides the steps of measuring light absorbance of the colored solute at the two different transmitted light wavelengths, and comparing the light absorbance of the colored solute at the two different wavelengths to determine a chemical property of an aqueous solution.

  17. Imaging spectrometer wide field catadioptric design

    DOEpatents

    Chrisp,; Michael, P [Danville, CA

    2008-08-19

    A wide field catadioptric imaging spectrometer with an immersive diffraction grating that compensates optical distortions. The catadioptric design has zero Petzval field curvature. The imaging spectrometer comprises an entrance slit for transmitting light, a system with a catadioptric lens and a dioptric lens for receiving the light and directing the light, an immersion grating, and a detector array. The entrance slit, the system for receiving the light, the immersion grating, and the detector array are positioned wherein the entrance slit transmits light to the system for receiving the light and the system for receiving the light directs the light to the immersion grating and the immersion grating receives the light and directs the light through the system for receiving the light to the detector array.

  18. Improving NIR snow pit stratigraphy observations by introducing a controlled NIR light source

    NASA Astrophysics Data System (ADS)

    Dean, J.; Marshall, H.; Rutter, N.; Karlson, A.

    2013-12-01

    Near-infrared (NIR) photography in a prepared snow pit measures mm-/grain-scale variations in snow structure, as reflectivity is strongly dependent on microstructure and grain size at the NIR wavelengths. We explore using a controlled NIR light source to maximize signal to noise ratio and provide uniform incident, diffuse light on the snow pit wall. NIR light fired from the flash is diffused across and reflected by an umbrella onto the snow pit; the lens filter transmits NIR light onto the spectrum-modified sensor of the DSLR camera. Lenses are designed to refract visible light properly, not NIR light, so there must be a correction applied for the subsequent NIR bright spot. To avoid interpolation and debayering algorithms automatically performed by programs like Adobe's Photoshop on the images, the raw data are analyzed directly in MATLAB. NIR image data show a doubling of the amount of light collected in the same time for flash over ambient lighting. Transitions across layer boundaries in the flash-lit image are detailed by higher camera intensity values than ambient-lit images. Curves plotted using median intensity at each depth, normalized to the average profile intensity, show a separation between flash- and ambient-lit images in the upper 10-15 cm; the ambient-lit image curve asymptotically approaches the level of the flash-lit image curve below 15cm. We hypothesize that the difference is caused by additional ambient light penetrating the upper 10-15 cm of the snowpack from above and transmitting through the wall of the snow pit. This indicates that combining NIR ambient and flash photography could be a powerful technique for studying penetration depth of radiation as a function of microstructure and grain size. The NIR flash images do not increase the relative contrast at layer boundaries; however, the flash more than doubles the amount of recorded light and controls layer noise as well as layer boundary transition noise.

  19. Exact first order scattering correction for vector radiative transfer in coupled atmosphere and ocean systems

    NASA Astrophysics Data System (ADS)

    Zhai, Peng-Wang; Hu, Yongxiang; Josset, Damien B.; Trepte, Charles R.; Lucker, Patricia L.; Lin, Bing

    2012-06-01

    We have developed a Vector Radiative Transfer (VRT) code for coupled atmosphere and ocean systems based on the successive order of scattering (SOS) method. In order to achieve efficiency and maintain accuracy, the scattering matrix is expanded in terms of the Wigner d functions and the delta fit or delta-M technique is used to truncate the commonly-present large forward scattering peak. To further improve the accuracy of the SOS code, we have implemented the analytical first order scattering treatment using the exact scattering matrix of the medium in the SOS code. The expansion and truncation techniques are kept for higher order scattering. The exact first order scattering correction was originally published by Nakajima and Takana.1 A new contribution of this work is to account for the exact secondary light scattering caused by the light reflected by and transmitted through the rough air-sea interface.

  20. Single-beam dielectric-microsphere trapping with optical heterodyne detection

    NASA Astrophysics Data System (ADS)

    Rider, Alexander D.; Blakemore, Charles P.; Gratta, Giorgio; Moore, David C.

    2018-01-01

    A technique to levitate and measure the three-dimensional position of micrometer-sized dielectric spheres with heterodyne detection is presented. The two radial degrees of freedom are measured by interfering light transmitted through the microsphere with a reference wavefront, while the axial degree of freedom is measured from the phase of the light reflected from the surface of the microsphere. This method pairs the simplicity and accessibility of single-beam optical traps to a measurement of displacement that is intrinsically calibrated by the wavelength of the trapping light and has exceptional immunity to stray light. A theoretical shot noise limit of 1.3 ×10-13 m /√{Hz } for the radial degrees of freedom, and 3.0 ×10-15 m /√{Hz } for the axial degree of freedom can be obtained in the system described. The measured acceleration noise in the radial direction is 7.5 ×10-5 (m /s2) /√{Hz } .

  1. LED lamp

    DOEpatents

    Galvez, Miguel; Grossman, Kenneth; Betts, David

    2013-11-12

    There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

  2. Müller glial cells contribute to dim light vision in the spectacled caiman (Caiman crocodilus fuscus): Analysis of retinal light transmission.

    PubMed

    Agte, Silke; Savvinov, Alexey; Karl, Anett; Zayas-Santiago, Astrid; Ulbricht, Elke; Makarov, Vladimir I; Reichenbach, Andreas; Bringmann, Andreas; Skatchkov, Serguei N

    2018-05-16

    In this study, we show the capability of Müller glial cells to transport light through the inverted retina of reptiles, specifically the retina of the spectacled caimans. Thus, confirming that Müller cells of lower vertebrates also improve retinal light transmission. Confocal imaging of freshly isolated retinal wholemounts, that preserved the refractive index landscape of the tissue, indicated that the retina of the spectacled caiman is adapted for vision under dim light conditions. For light transmission experiments, we used a setup with two axially aligned objectives imaging the retina from both sides to project the light onto the inner (vitreal) surface and to detect the transmitted light behind the retina at the receptor layer. Simultaneously, a confocal microscope obtained images of the Müller cells embedded within the vital tissue. Projections of light onto several representative Müller cell trunks within the inner plexiform layer, i.e. (i) trunks with a straight orientation, (ii) trunks which are formed by the inner processes and (iii) trunks which get split into inner processes, were associated with increases in the intensity of the transmitted light. Projections of light onto the periphery of the Müller cell endfeet resulted in a lower intensity of transmitted light. In this way, retinal glial (Müller) cells support dim light vision by improving the signal-to-noise ratio which increases the sensitivity to light. The field of illuminated photoreceptors mainly include rods reflecting the rod dominance of the of tissue. A subpopulation of Müller cells with downstreaming cone cells led to a high-intensity illumination of the cones, while the surrounding rods were illuminated by light of lower intensity. Therefore, Müller cells that lie in front of cones may adapt the intensity of the transmitted light to the different sensitivities of cones and rods, presumably allowing a simultaneous vision with both receptor types under dim light conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Amplitude and phase measurements based on low-coherence interferometry with acousto-optic spectral image filtration

    NASA Astrophysics Data System (ADS)

    Machikhin, Alexander; Burmak, Ludmila; Pozhar, Vitold

    2018-04-01

    The manuscript addresses the advantages and possible applications of acousto-optic image spectral filtration in lowcoherence interferometry. In particular, an effective operation of acousto-optical tunable filters in combination with Michelson-type interferometers is shown. The results of original experiments are presented. It is demonstrated that amplitude and phase spatial distributions of light waves reflected from or transmitted through the object can be fast determined in contactless manner for any spectral intervals with use of the presented techniques.

  4. Near-infrared spectral methods for noninvasively measuring blood glucose

    NASA Astrophysics Data System (ADS)

    Fei, Sun; Kong, Deyi; Mei, Tao; Tao, Yongchun

    2004-05-01

    Determination of blood glucose concentrations in diabetic patients is a frequently occurring procedure and an important tool for diabetes management. Use of noninvasive detection techniques can relieve patients from the pain of frequent finger pokes and avoid the infection of disease via blood. This thesis discusses current research and analyzes the advantages and shortages of different measurement methods, including: optical methods (Transmission, Polarimetry and scattering), then, we give emphasis to analyze the technology of near-infrared (NIR) spectra. NIR spectral range 700 nm ~2300 nm was used because of its good transparency for biological tissue and presence of glucose absorption band. In this work, we present an outline of noninvasive blood glucose measurement. A near-infrared light beam is passed through the finger, and the spectral components of the emergent beam are measured using spectroscopic techniques. The device includes light sources having the wavelengths of 600 nm - 1800 nm to illuminate the tissue. Receptors associated with the light sources for receiving light and generating a transmission signal representing the light transmitted are also provided. Once a transmission signal is received by receptors, and the high and low values from each of the signals are stored in the device. The averaged values are then analyzed to determine the glucose concentration, which is displayed on the device.

  5. Mesoscopic effect of spectral modulation for the light transmitted by a SNOM tip

    NASA Astrophysics Data System (ADS)

    Rähn, M.; Pärs, M.; Palm, V.; Jaaniso, R.; Hizhnyakov, V.

    2010-06-01

    The effect of a tapered metal-coated optical fiber terminated by a sub-wavelength aperture (SWA) on the spectrum of the transmitted light is investigated experimentally. Under certain conditions a remarkable spectral modulation of the transmitted light can be observed. This effect is of a mesoscopic origin, occurring only for a certain interval of SWA diameters. One can conclude that a noticeable modulation appears when the number of the transmitted fiber modes is small but exceeds unity, thus indicating the presence of a phase shift between different modes. To discern between two possible sources of such phase shift, the fiber length dependence of the output spectrum has been studied. According to the results obtained for the used sample of 200 nm SNOM tip, the observed phase shift is mostly caused rather by the inherent modal dispersion of the multimode fiber than by the mode-dependent light slowdown in the tapered region close to SWA due to the coupling to surface plasmons of the metal coating. The SWA acts here mainly as an effective mode filter.

  6. Depth of composite polymerization within simulated root canals using light-transmitting posts.

    PubMed

    Lui, J L

    1994-01-01

    In this study, the depth of cure of composite resins cured within simulated root canals by means of light-transmitting plastic posts was compared to that achieved by the conventional light-curing method. Six sizes of posts with diameters of 1.05 mm, 1.20 mm, 1.35 mm, 1.50 mm, 1.65 mm, and 1.80 mm were investigated. In general, the larger the post diameter, the greater was the depth of cure. There were significant differences in the depth of cure between the control and all sizes of posts investigated. There were also significant differences between the various post diameters except for the 1.35 mm and 1.50 mm diameter posts. It was possible to achieve a depth of cure exceeding 11 mm using these light-transmitting posts.

  7. Coherent control of the Goos-Hänchen shift via Fano interference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Shaopeng; Yang, Wen-Xing, E-mail: wenxingyang@seu.edu.cn; Zhu, Zhonghu

    2016-04-14

    A scheme of enhanced Goos-Hänchen (GH) shifts in reflected and transmitted light beams is exploited in a cavity, where an asymmetric double AlGaAs/GaAs quantum well structure with resonant tunneling to a common continuum is employed as the intracavity medium. With the help of Fano-type interference induced by resonant tunneling, the generated GH shifts that contain a negative lateral shift in reflected light beam and a positive lateral shift in transmitted light beam are found to be significantly enhanced. More interestingly, these GH shifts in reflected and transmitted light beams are modulated by means of a control beam and external biasmore » voltage, in which maximum negative shift of 1.86 mm and positive shift of 0.37 mm are achievable.« less

  8. Method for detection of dental caries and periodontal disease using optical imaging

    DOEpatents

    Nathel, Howard; Kinney, John H.; Otis, Linda L.

    1996-01-01

    A method for detecting the presence of active and inactive caries in teeth and diagnosing periodontal disease uses non-ionizing radiation with techniques for reducing interference from scattered light. A beam of non-ionizing radiation is divided into sample and reference beams. The region to be examined is illuminated by the sample beam, and reflected or transmitted radiation from the sample is recombined with the reference beam to form an interference pattern on a detector. The length of the reference beam path is adjustable, allowing the operator to select the reflected or transmitted sample photons that recombine with the reference photons. Thus radiation scattered by the dental or periodontal tissue can be prevented from obscuring the interference pattern. A series of interference patterns may be generated and interpreted to locate dental caries and periodontal tissue interfaces.

  9. A technique for simultaneous detection of individual vortex states of Laguerre-Gaussian beams transmitted through an aqueous suspension of microparticles

    NASA Astrophysics Data System (ADS)

    Khonina, S. N.; Karpeev, S. V.; Paranin, V. D.

    2018-06-01

    A technique for simultaneous detection of individual vortex states of the beams propagating in a randomly inhomogeneous medium is proposed. The developed optical system relies on the correlation method that is invariant to the beam wandering. The intensity distribution formed at the optical system output does not require digital processing. The proposed technique based on a multi-order phase diffractive optical element (DOE) is studied numerically and experimentally. The developed detection technique is used for the analysis of Laguerre-Gaussian vortex beams propagating under conditions of intense absorption, reflection, and scattering in transparent and opaque microparticles in aqueous suspensions. The performed experimental studies confirm the relevance of the vortex phase dependence of a laser beam under conditions of significant absorption, reflection, and scattering of the light.

  10. Optical probe for determining the fat/lean interface in cuts of meat

    DOEpatents

    Weber, Thomas M.; Callow, Diane S.; Jones, James F.; Kuehl, Michael A.; Spletzer, Barry L.

    2005-02-22

    An apparatus and method for locating the boundary surface between a layer of fatty tissue and lean tissue in a cut of meat, such as beef, such as slabs of meat undergoing trimming and cutting in commercial meet processing facilitates. The invention exploits the fact that fatty tissue and lean tissue have significantly different responses to incident light energy. By gauging the degree to which a generated beam of light is scattered and reflected by the tissues under evaluation, the invention permits the character of the tissue to be ascertained. An incident beam of light, such as green light, is generated and transmitted to a probe tip, which tip is inserted into the cut of meat under investigation. The light beam is emitted into the meat tissues from the probe tip, and then is scattered and reflected by the tissues, whereupon some fraction of the emitted light returns to the probe tip. The returning light energy is transmitted to a detector; relative changes in the returning light transmitted to the detector permit the operator to determine when the probe tip is approaching or penetrating the fat/lean tissue interface.

  11. Interaction of Polarized Light with Chalcogenide Glasses

    DTIC Science & Technology

    2001-06-01

    simultaneous measurement of the laser radiation transmitted through the bulk sample and radiation scattered by the sample to various angles up to 230...fixed in the central part of the lens, reflected the transmitted light beam to a second photodiode. He-Ne laser radiation (), = 633 nm) which was sub...band-gap radiation for the studied bulk glass samples (As 2S3 glass) played in this installation, by turns, a role of inducing or probing light. This

  12. Fiber optic monitoring device

    DOEpatents

    Samborsky, James K.

    1993-01-01

    A device for the purpose of monitoring light transmissions in optical fibers comprises a fiber optic tap that optically diverts a fraction of a transmitted optical signal without disrupting the integrity of the signal. The diverted signal is carried, preferably by the fiber optic tap, to a lens or lens system that disperses the light over a solid angle that facilitates viewing. The dispersed light indicates whether or not the monitored optical fiber or system of optical fibers is currently transmitting optical information.

  13. Transparent selective illumination means suitable for use in optically activated electrical switches and optically activated electrical switches constructed using same

    DOEpatents

    Wilcox, R.B.

    1991-09-10

    A planar transparent light conducting means and an improved optically activated electrical switch made using the novel light conducting means are disclosed. The light conducting means further comprise light scattering means on one or more opposite planar surfaces thereof to transmit light from the light conducting means into adjacent media and reflective means on other surfaces of the light conducting means not containing the light scattering means. The optically activated electrical switch comprises at least two stacked photoconductive wafers, each having electrodes formed on both surfaces thereof, and separated by the planar transparent light conducting means. The light scattering means on the light conducting means face surfaces of the wafers not covered by the electrodes to transmit light from the light conducting means into the photoconductive wafers to uniformly illuminate and activate the switch. 11 figures.

  14. Transparent selective illumination means suitable for use in optically activated electrical switches and optically activated electrical switches constructed using same

    DOEpatents

    Wilcox, Russell B.

    1991-01-01

    A planar transparent light conducting means and an improved optically activated electrical switch made using the novel light conducting means are disclosed. The light conducting means further comprise light scattering means on one or more opposite planar surfaces thereof to transmit light from the light conducting means into adjacent media and reflective means on other surfaces of the light conducting means not containing the light scattering means. The optically activated electrical switch comprises at least two stacked photoconductive wafers, each having electrodes formed on both surfaces thereof, and separated by the planar transparent light conducting means. The light scattering means on the light conducting means face surfaces of the wafers not covered by the electrodes to transmit light from the light conducting means into the photoconductive wafers to uniformly illuminate and activate the switch.

  15. Unidirectional transmission realized by two nonparallel gratings made of isotropic media.

    PubMed

    Ye, Wei-Min; Yuan, Xiao-Dong; Zeng, Chun

    2011-08-01

    We realize a unidirectional transmission by cascading two nonparallel gratings (NPGs) made of isotropic, lossless, and linear media. For a pair of orthogonal linear polarizations, one of the gratings is designed as a polarizer, which is a reflector for one polarization and a transmitter for the other; another grating is designed as a polarization converter, which converts most of one polarized incident wave into another polarized transmitted wave. It is demonstrated by numerical calculation that more than 85% of the incident light energy can be transmitted with less than 1% transmission in the opposite direction for linearly polarized light at normal incidence, and the relative bandwidth of the unidirectional transmission is nearly 9%. The maximum transmission contrast ratio between the two directions is 62 dB. Unlike one-way diffraction grating, the transmitted light of the NPGs is collinear with the incident light, but their polarizations are orthogonal. © 2011 Optical Society of America

  16. Fiber fault location utilizing traffic signal in optical network.

    PubMed

    Zhao, Tong; Wang, Anbang; Wang, Yuncai; Zhang, Mingjiang; Chang, Xiaoming; Xiong, Lijuan; Hao, Yi

    2013-10-07

    We propose and experimentally demonstrate a method for fault location in optical communication network. This method utilizes the traffic signal transmitted across the network as probe signal, and then locates the fault by correlation technique. Compared with conventional techniques, our method has a simple structure and low operation expenditure, because no additional device is used, such as light source, modulator and signal generator. The correlation detection in this method overcomes the tradeoff between spatial resolution and measurement range in pulse ranging technique. Moreover, signal extraction process can improve the location result considerably. Experimental results show that we achieve a spatial resolution of 8 cm and detection range of over 23 km with -8-dBm mean launched power in optical network based on synchronous digital hierarchy protocols.

  17. Effect of Thickness on Light Transmission and Vickers Hardness of Five Bulk-fill Resin-based Composites Using Polywave and Single-peak Light-emitting Diode Curing Lights.

    PubMed

    Maghaireh, G A; Price, R B; Abdo, N; Taha, N A; Alzraikat, H

    2018-06-28

    This study compared light transmission through different thicknesses of bulk-fill resin-based composites (RBCs) using a polywave and a single-peak light-emitting diode light-curing unit (LCU). The effect on the surface hardness was also evaluated. Five bulk-fill RBCs were tested. Specimens (n=5) of 1-, 2-, 4-, or 6-mm thickness were photopolymerized for 10 seconds from the top using a polywave (Bluephase Style) or single-peak (Elipar S10) LCU, while a spectrophotometer monitored in real time the transmitted irradiance and radiant exposure reaching the bottom of the specimen. After 24 hours of storage in distilled water at 37°C, the Vickers microhardness (VH) was measured at top and bottom. Results were analyzed using multiple-way analysis of variance, Tukey post hoc tests, and multivariate analysis (α=0.05). The choice of LCU had no significant effect on the total amount of light transmitted through the five bulk-fill RBCs at each thickness. There was a significant decrease in the amount of light transmitted as the thickness increased for all RBCs tested with both LCUs ( p<0.001). Effect of LCU on VH was minimal (η p 2 =0.010). The 1-, 2-, and 4-mm-thick specimens of SDR, X-tra Fill, and Filtek Bulk Restorative achieved a VH bottom/top ratio of approximately 80% when either LCU was used. The total amount of light transmitted through the five bulk-fill RBCs was similar at the different thicknesses using either LCU. The polywave LCU used in this study did not enhance the polymerization of the tested bulk-fill RBCs when compared with the single-peak LCU.

  18. Characterization of the angular memory effect of scattered light in biological tissues.

    PubMed

    Schott, Sam; Bertolotti, Jacopo; Léger, Jean-Francois; Bourdieu, Laurent; Gigan, Sylvain

    2015-05-18

    High resolution optical microscopy is essential in neuroscience but suffers from scattering in biological tissues and therefore grants access to superficial brain layers only. Recently developed techniques use scattered photons for imaging by exploiting angular correlations in transmitted light and could potentially increase imaging depths. But those correlations ('angular memory effect') are of a very short range and should theoretically be only present behind and not inside scattering media. From measurements on neural tissues and complementary simulations, we find that strong forward scattering in biological tissues can enhance the memory effect range and thus the possible field-of-view by more than an order of magnitude compared to isotropic scattering for ∼1 mm thick tissue layers.

  19. Modeling optical transmissivity of graphene grate in on-chip silicon photonic device

    NASA Astrophysics Data System (ADS)

    Amiri, Iraj S.; Ariannejad, M. M.; Jalil, M. A.; Ali, J.; Yupapin, P.

    2018-06-01

    A three-dimensional (3-D) finite-difference-time-domain (FDTD) analysis was used to simulate a silicon photonic waveguide. We have calculated power and transmission of the graphene used as single or multilayers to study the light transmission behavior. A new technique has been developed to define the straight silicon waveguide integrated with grate graphene layer. The waveguide has a variable grate spacing to be filled by the graphene layer. The number of graphene atomic layers varies between 100 and 1000 (or 380 nm and 3800 nm), the transmitted power obtained varies as ∼30% and ∼80%. The ∼99%, blocking of the light was occurred in 10,000 (or 38,000 nm) atomic layers of the graphene grate.

  20. An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

    NASA Technical Reports Server (NTRS)

    Ryan, Robert E.; Underwood, Lauren W.; ONeal, Duane; Pagnutti, Mary; Davis, Bruce A.

    2009-01-01

    A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor dye degradation on the slides over time, a temperature-stabilized white light LED was used to illuminate the opposite side of the slides. As the dye degraded, the amount of light from the white light LED transmitted through the slide was monitored with a spectrometer and subsequently analyzed to determine and compare the rate of dye degradation for photocatalytically coated versus uncoated slide surfaces. The long-term stability of the spectrometer/white light LED combination, which required only a single reference spectra to be taken for a time series sequence of several hours, enabled accurate measurements of transmitted light over time. Time series transmission curves were generated and results demonstrated that over time the transmission increased much more rapidly on the coated slides than on the control slides. This experimental configuration and methodology for photocatalytic activity measurement minimizes many external variable effects and allows low light level studies to be performed. This study also compares the advantages of this novel LED light source design to traditional mercury lamp systems and non-LED lamp approaches that have conventionally been used. The methodology and experimental design research summarized in this abstract is partly funded by the Department of Homeland Security, Science and Technology Directorate, and by the NASA Stennis Space Center Innovative Partnerships Program.

  1. Sub-wavelength efficient polarization filter (SWEP filter)

    DOEpatents

    Simpson, Marcus L.; Simpson, John T.

    2003-12-09

    A polarization sensitive filter includes a first sub-wavelength resonant grating structure (SWS) for receiving incident light, and a second SWS. The SWS are disposed relative to one another such that incident light which is transmitted by the first SWS passes through the second SWS. The filter has a polarization sensitive resonance, the polarization sensitive resonance substantially reflecting a first polarization component of incident light while substantially transmitting a second polarization component of the incident light, the polarization components being orthogonal to one another. A method for forming polarization filters includes the steps of forming first and second SWS, the first and second SWS disposed relative to one another such that a portion of incident light applied to the first SWS passes through the second SWS. A method for separating polarizations of light, includes the steps of providing a filter formed from a first and second SWS, shining incident light having orthogonal polarization components on the first SWS, and substantially reflecting one of the orthogonal polarization components while substantially transmitting the other orthogonal polarization component. A high Q narrowband filter includes a first and second SWS, the first and second SWS are spaced apart a distance being at least one half an optical wavelength.

  2. Solar Cell Modules With Improved Backskin

    DOEpatents

    Gonsiorawski, Ronald C.

    2003-12-09

    A laminated solar cell module comprises a front light transmitting support, a plurality of interconnected solar cells encapsulated by a light-transmitting encapsulant material, and an improved backskin formed of an ionomer/nylon alloy. The improved backskin has a toughness and melting point temperature sufficiently great to avoid any likelihood of it being pierced by any of the components that interconnect the solar cells.

  3. Effect of part thickness, glass fiber and crystallinity on light scattering during laser transmission welding of thermoplastics

    NASA Astrophysics Data System (ADS)

    Xu, Xin Feng; Parkinson, Alexander; Bates, Philip J.; Zak, Gene

    2015-12-01

    It is important to understand how laser energy scatters within the transparent component in order to predict and optimize the laser transmission welding process. This paper examines the influence of part thickness, glass fiber and crystallinity levels on the distribution of laser light after transmission through amorphous polycarbonate (PC) and semi-crystalline polymers such as polyamide 6 (PA6), polypropylene (PP), and polyethylene (PE). An experimental technique based on laser-scanned lines of progressively increasing power was used to assess the transmitted energy distribution. This distribution was characterized using a two-parameter model that captures scattered and un-scattered components of the laser beam. The results clearly show how the scattering is increased by increasing the numbers of interactions between laser light and phase boundaries either by increasing the particle concentration (i.e., glass fiber level and crystallinity) or increasing part thickness.

  4. Diagnostic monitoring by infrared imaging of avian embryos

    NASA Astrophysics Data System (ADS)

    Wurzbach, Richard N.

    1998-03-01

    For large scale chicken and turkey raising operations, automated 'candling' of eggs for monitoring embryonic development is effective and efficient. Candling is accomplished by the transmission of high intensity light such that it penetrates the translucent egg and gives indications of embryonic position and development. When monitoring the development of other species, however, mixed results are obtained with this technique. For instance, the Emu egg is virtually opaque to transmitted visible light, and thus cannot be candled by traditional means. During the development cycle all avian embryos, and for that mater all egg-laying creatures, exhibit changes in shell surface temperatures that indicate on-going development, or a lack of that development. Additionally, such hazards as bacterial or viral growth within the shell produce atypical thermal signatures. Analysis of the shell surface temperatures may be useful in monitoring the development of these embryos. Further applications of IR thermography in farming of avian species may make it an economically viable monitoring technique.

  5. Measurement of Ambient Air Motion of D. I. Gasoline Spray by LIF-PIV

    NASA Astrophysics Data System (ADS)

    Yamakawa, Masahisa; Isshiki, Seiji; Yoshizaki, Takuo; Nishida, Keiya

    Ambient air velocity distributions in and around a D. I. gasoline spray were measured using a combination of LIF and PIV techniques. A rhodamine and water solution was injected into ambient air to disperse the fine fluorescent liquid particles used as tracers. A fuel spray was injected into the fluorescent tracer cloud and was illuminated by an Nd: YAG laser light sheet (532nm). The scattered light from the spray droplets and tracers was cut off by a high-pass filter (>560nm). As the fluorescence (>600nm) was transmitted through the high-pass filter, the tracer images were captured using a CCD camera and the ambient air velocity distribution could be obtained by PIV based on the images. This technique was applied to a D. I. gasoline spray. The ambient air flowed up around the spray and entered into the tail of the spray. Furthermore, the relative velocity between the spray and ambient air was investigated.

  6. Method for detection of dental caries and periodontal disease using optical imaging

    DOEpatents

    Nathel, H.; Kinney, J.H.; Otis, L.L.

    1996-10-29

    A method is disclosed for detecting the presence of active and inactive caries in teeth and diagnosing periodontal disease uses non-ionizing radiation with techniques for reducing interference from scattered light. A beam of non-ionizing radiation is divided into sample and reference beams. The region to be examined is illuminated by the sample beam, and reflected or transmitted radiation from the sample is recombined with the reference beam to form an interference pattern on a detector. The length of the reference beam path is adjustable, allowing the operator to select the reflected or transmitted sample photons that recombine with the reference photons. Thus radiation scattered by the dental or periodontal tissue can be prevented from obscuring the interference pattern. A series of interference patterns may be generated and interpreted to locate dental caries and periodontal tissue interfaces. 7 figs.

  7. Laser fiber cleaving techniques: effects on tip morphology and power output.

    PubMed

    Vassantachart, Janna M; Lightfoot, Michelle; Yeo, Alexander; Maldonado, Jonathan; Li, Roger; Alsyouf, Muhannad; Martin, Jacob; Lee, Michael; Olgin, Gaudencio; Baldwin, D Duane

    2015-01-01

    Proper cleaving of reusable laser fibers is needed to maintain optimal functionality. This study quantifies the effect of different cleaving tools on power output of the holmium laser fiber and demonstrates morphologic changes using microscopy. The uncleaved tips of new 272 μm reusable laser fibers were used to obtain baseline power transmission values at 3 W (0.6 J, 5 Hz). Power output for each of four cleaving techniques-11-blade scalpel, scribe pen cleaving tool, diamond cleaving wheel, and suture scissors-was measured in a single-blinded fashion. Dispersion of light from the fibers was compared with manufacturer specifications and rated as "ideal," "acceptable," or "unacceptable" by blinded reviewers. The fiber tips were also imaged using confocal and scanning electron microscopy. Independent samples Kruskal-Wallis test and chi square were used for statistical analysis (α<0.05). New uncleaved fiber tips transmitted 3.04 W of power and were used as a reference (100%). The scribe pen cleaving tool produced the next highest output (97.1%), followed by the scalpel (83.4%), diamond cleaving wheel (77.1%), and suture scissors (61.7%), a trend that was highly significant (P<0.001). On pairwise comparison, no difference in power output was seen between the uncleaved fiber tips and those cleaved with the scribe pen (P=1.0). The rating of the light dispersion patterns from the different cleaving methods followed the same trend as the power output results (P<0.001). Microscopy showed that the scribe pen produced small defects along the fiber cladding but maintained a smooth, flat core surface. The other cleaving techniques produced defects on both the core and cladding. Cleaving techniques produce a significant effect on the initial power transmitted by reusable laser fibers. The scribe pen cleaving tool produced the most consistent and highest average power output.

  8. Soil transmitted helminths and schistosoma mansoni infections among school children in Zarima town, northwest Ethiopia.

    PubMed

    Alemu, Abebe; Atnafu, Asmamaw; Addis, Zelalem; Shiferaw, Yitayal; Teklu, Takele; Mathewos, Biniam; Birhan, Wubet; Gebretsadik, Simon; Gelaw, Baye

    2011-07-09

    In Ethiopia, because of low quality drinking water supply and latrine coverage, helminths infections are the second most predominant causes of outpatient morbidity. Indeed, there is a scarcity of information on the prevalence of soil transmitted helminths and Schistosomiasis in Ethiopia, special in study area. Therefore, the aim of this study was to determine the prevalence and associated risk factors of soil transmitted helminths and intestinal Schistosomiasis. Cross-sectional study was conducted among 319 school children of Zarima town from April 1 to May 25, 2009. A pre-tested structured questionnaire was used to collect socio-demographic data and possible risk factors exposure. Early morning stool samples were collected and a Kato Katz semi concentration technique was used to examine and count parasitic load by compound light microscope. Data entry and analysis was done using SPSS-15 version and p-value < 0.05 considered statistically significant. Out of 319 study subjects, 263 (82.4%) of the study participants infected with one or more parasites. From soil transmitted helminths, Ascaris lumbricoides was the predominant isolate (22%) followed by Hookworms (19%) and Trichuris trichiura (2.5%). Schistosoma mansoni was also isolated in 37.9% of the study participants. Hookworm and S. mansoni infections showed statistically significant associations with shoe wearing and swimming habit of school children, respectively. Prevalence of soil transmitted helminths (STH) and S.mansoni was high and the diseases were still major health problem in the study area which alerts public health intervention as soon as possible.

  9. Transmitted light relaxation and microstructure evolution of ferrofluids under gradient magnetic fields

    NASA Astrophysics Data System (ADS)

    Huang, Yan; Li, Decai; Li, Feng; Zhu, Quanshui; Xie, Yu

    2015-03-01

    Using light transmission experiments and optical microscope observations with a longitudinal gradient magnetic field configuration, the relationship between the behavior of the transmitted light relaxation and the microstructure evolution of ionic ferrofluids in the central region of an axisymmetric field is investigated. Under a low-gradient magnetic field, there are two types of relaxation process. When a field is applied, the transmitted light intensity decreases to a minimum within a time on the order of 101-102 s. It is then gradually restored, approaching its initial value within a time on the order of 102 s. This is type I relaxation, which corresponds to the formation of magnetic columns. After the transmission reaches this value, it either increases or decreases slowly, stabilizing within a time on the order of 103 s, according to the direction of the field gradient. This is a type II relaxation, which results from the shadowing effect, corresponding to the motion of the magnetic columns under the application of a gradient force. Under a magnetic field with a centripetal high-gradient (magnetic materials subjected to a force pointing toward the center of the axisymmetric field), the transmitted light intensity decreases monotonously and more slowly than that under a low-gradient field. Magnetic transport and separation resulted from magnetophoresis under high-gradient fields, changing the formation dynamics of the local columns and influencing the final state of the column system.

  10. More Poop, More Precision: Improving Epidemiologic Surveillance of Soil-Transmitted Helminths with Multiple Fecal Sampling using the Kato-Katz Technique.

    PubMed

    Liu, Chengfang; Lu, Louise; Zhang, Linxiu; Bai, Yu; Medina, Alexis; Rozelle, Scott; Smith, Darvin Scott; Zhou, Changhai; Zang, Wei

    2017-09-01

    Soil-transmitted helminths, or parasitic intestinal worms, are among the most prevalent and geographically widespread parasitic infections in the world. Accurate diagnosis and quantification of helminth infection are critical for informing and assessing deworming interventions. The Kato-Katz thick smear technique, the most widely used laboratory method to quantitatively assess infection prevalence and infection intensity of helminths, has often been compared with other methods. Only a few small-scale studies, however, have considered ways to improve its diagnostic sensitivity. This study, conducted among 4,985 school-age children in an area of rural China with moderate prevalence of helminth infection, examines the effect on diagnostic sensitivity of the Kato-Katz technique when two fecal samples collected over consecutive days are examined and compared with a single sample. A secondary aim was to consider cost-effectiveness by calculating an estimate of the marginal costs of obtaining an additional fecal sample. Our findings show that analysis of an additional fecal sample led to increases of 23%, 26%, and 100% for Ascaris lumbricoides, Trichuris trichiura , and hookworm prevalence, respectively. The cost of collecting a second fecal sample for our study population was approximately USD4.60 per fecal sample. Overall, the findings suggest that investing 31% more capital in fecal sample collection prevents an underestimation of prevalence by about 21%, and hence improves the diagnostic sensitivity of the Kato-Katz method. Especially in areas with light-intensity infections of soil-transmitted helminths and limited public health resources, more accurate epidemiological surveillance using multiple fecal samples will critically inform decisions regarding infection control and prevention.

  11. Single-lens computed tomography imaging spectrometer and method of capturing spatial and spectral information

    NASA Technical Reports Server (NTRS)

    Wilson, Daniel W. (Inventor); Johnson, William R. (Inventor); Bearman, Gregory H. (Inventor)

    2011-01-01

    Computed tomography imaging spectrometers ("CTISs") employing a single lens are provided. The CTISs may be either transmissive or reflective, and the single lens is either configured to transmit and receive uncollimated light (in transmissive systems), or is configured to reflect and receive uncollimated light (in reflective systems). An exemplary transmissive CTIS includes a focal plane array detector, a single lens configured to transmit and receive uncollimated light, a two-dimensional grating, and a field stop aperture. An exemplary reflective CTIS includes a focal plane array detector, a single mirror configured to reflect and receive uncollimated light, a two-dimensional grating, and a field stop aperture.

  12. Shining a light on high volume photocurable materials.

    PubMed

    Palin, William M; Leprince, Julian G; Hadis, Mohammed A

    2018-05-01

    Spatial and temporal control is a key advantage for placement and rapid setting of light-activated resin composites. Conventionally, placement of multiple thin layers (<2mm) reduces the effect of light attenuation through highly filled and pigmented materials to increase polymerisation at the base of the restoration. However, and although light curing greater than 2mm thick layers is not an entirely new phenomenon, the desire amongst dental practitioners for even more rapid processing in deep cavities has led to the growing acceptance of so-called "bulk fill" (4-6mm thick) resin composites that are irradiated for 10-20s in daily clinical practice. The change in light transmission and attenuation during photopolymerisation are complex and related to path length, absorption properties of the photoinitiator and pigment, optical properties of the resin and filler and filler morphology. Understanding how light is transmitted through depth is therefore critical for ensuring optimal material properties at the base of thick increments. This article will briefly highlight the advent of current commercial materials that rationalise bulk filling techniques in dentistry, the relationship between light transmission and polymerisation and how optimal curing depths might be achieved. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  13. Extraction of quasi-straightforward-propagating photons from diffused light transmitting through a scattering medium by polarization modulation

    NASA Astrophysics Data System (ADS)

    Horinaka, Hiromichi; Hashimoto, Koji; Wada, Kenji; Cho, Yoshio; Osawa, Masahiko

    1995-07-01

    The utilization of light polarization is proposed to extract quasi-straightforward-propagating photons from diffused light transmitting through a scattering medium under continuously operating conditions. Removal of a floor level normally appearing on the dynamic range over which the extraction capability is maintained is demonstrated. By use of pulse-based observations this cw scheme of extraction of quasi-straightforward-propagating photons is directly shown to be equivalent to the use of a temporal gate in the pulse-based operation.

  14. Selective detection of Escherichia coli by imaging of the light intensity transmitted through an optical disk

    NASA Astrophysics Data System (ADS)

    Shiramizu, Hideyuki; Kuroda, Chiaki; Ohki, Yoshimichi; Shima, Takayuki; Wang, Xiaomin; Fujimaki, Makoto

    2018-03-01

    We have developed an optical disk system for imaging transmitted light from Escherichia coli dispersed on an optical disk. When E. coli was stained using Bismarck brown, the transmittance was found to decrease in images obtained at λ = 405 nm. The results indicate that transmittance imaging is suitable for finding the difference in light intensity between stained and unstained E. coli, whereas the reflectance images were scarcely changed by staining. Therefore, E. coli can be selectively discriminated from abiotic contaminants using transmittance imaging.

  15. Multispectral Imager With Improved Filter Wheel and Optics

    NASA Technical Reports Server (NTRS)

    Bremer, James C.

    2007-01-01

    Figure 1 schematically depicts an improved multispectral imaging system of the type that utilizes a filter wheel that contains multiple discrete narrow-band-pass filters and that is rotated at a constant high speed to acquire images in rapid succession in the corresponding spectral bands. The improvement, relative to prior systems of this type, consists of the measures taken to prevent the exposure of a focal-plane array (FPA) of photodetectors to light in more than one spectral band at any given time and to prevent exposure of the array to any light during readout. In prior systems, these measures have included, variously the use of mechanical shutters or the incorporation of wide opaque sectors (equivalent to mechanical shutters) into filter wheels. These measures introduce substantial dead times into each operating cycle intervals during which image information cannot be collected and thus incoming light is wasted. In contrast, the present improved design does not involve shutters or wide opaque sectors, and it reduces dead times substantially. The improved multispectral imaging system is preceded by an afocal telescope and includes a filter wheel positioned so that its rotation brings each filter, in its turn, into the exit pupil of the telescope. The filter wheel contains an even number of narrow-band-pass filters separated by narrow, spoke-like opaque sectors. The geometric width of each filter exceeds the cross-sectional width of the light beam coming out of the telescope. The light transmitted by the sequence of narrow-band filters is incident on a dichroic beam splitter that reflects in a broad shorter-wavelength spectral band that contains half of the narrow bands and transmits in a broad longer-wavelength spectral band that contains the other half of the narrow spectral bands. The filters are arranged on the wheel so that if the pass band of a given filter is in the reflection band of the dichroic beam splitter, then the pass band of the adjacent filter is in the longer-wavelength transmission band of the dichroic beam splitter (see Figure 2). Each of the two optical paths downstream of the dichroic beam splitter contains an additional broad-band-pass filter: The filter in the path of the light transmitted by the dichroic beam splitter transmits and attenuates in the same bands that are transmitted and reflected, respectively, by the beam splitter; the filter in the path of the light reflected by the dichroic beam splitter transmits and attenuates in the same bands that are reflected and transmitted, respectively, by the dichroic beam splitter. In each of these paths, the filtered light is focused onto an FPA. As the filter wheel rotates at a constant angular speed, its shaft angle is monitored, and the shaft-angle signal is used to synchronize the exposure times of the two FPAs. When a single narrowband-pass filter on the wheel occupies the entire cross section of the beam of light coming out of the telescope, the spectrum of light that reaches the dichroic beam splitter lies entirely within the pass band of that filter. Therefore, the beam in its entirety is either transmitted by the dichroic beam splitter and imaged on the longer-wavelength FPA or reflected by the beam splitter and imaged onto the shorter-wavelength FPA.

  16. Methods and Devices for Space Optical Communications Using Laser Beams

    NASA Technical Reports Server (NTRS)

    Goorjian, Peter M. (Inventor)

    2018-01-01

    Light is used to communicate between objects separated by a large distance. Light beams are received in a telescopic lens assembly positioned in front of a cat's-eye lens. The light can thereby be received at various angles to be output by the cat's-eye lens to a focal plane of the cat's-eye lens, the position of the light beams upon the focal plane corresponding to the angle of the beam received. Lasers and photodetectors are distributed along this focal plane. A processor receives signals from the photodetectors, and selectively signal lasers positioned proximate the photodetectors detecting light, in order to transmit light encoding data through the cat's-eye lens and also through a telescopic lens back in the direction of the received light beams, which direction corresponds to a location upon the focal plane of the transmitting lasers.

  17. High frequency modulation circuits based on photoconductive wide bandgap switches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sampayan, Stephen

    Methods, systems, and devices for high voltage and/or high frequency modulation. In one aspect, an optoelectronic modulation system includes an array of two or more photoconductive switch units each including a wide bandgap photoconductive material coupled between a first electrode and a second electrode, a light source optically coupled to the WBGP material of each photoconductive switch unit via a light path, in which the light path splits into multiple light paths to optically interface with each WBGP material, such that a time delay of emitted light exists along each subsequent split light path, and in which the WBGP materialmore » conducts an electrical signal when a light signal is transmitted to the WBGP material, and an output to transmit the electrical signal conducted by each photoconductive switch unit. The time delay of the photons emitted through the light path is substantially equivalent to the time delay of the electrical signal.« less

  18. Shedding Light on the Battlefield: Tactical Applications of Photonic Technology

    DTIC Science & Technology

    2004-11-01

    of the first applications of photonics to communications was the photophone ,1 demonstrated by Alexander Graham Bell in 1880, which used light beams to...transmit information wirelessly. Bell believed the invention of the photophone was more significant than that of the telephone, but it took almost... photophone used sunlight and vibrating mirrors to transmit the human voice. http://inventors.about.com/library/inventors/bltelephone3.htm, accessed April

  19. Development and optimization of a miniaturized fiber-optic photoplethysmographic sensor

    NASA Astrophysics Data System (ADS)

    Morley, Aisha; Davenport, John J.; Hickey, Michelle; Phillips, Justin P.

    2017-11-01

    Photoplethysmography (PPG) is a widely used technique for measuring blood oxygen saturation, commonly using an external pulse oximeter applied to a finger, toe, or earlobe. Previous research has demonstrated the utility of direct monitoring of the oxygen saturation of internal organs, using optical fibers to transmit light between the photodiode/light emitting diode and internal site. However, little research into the optimization and standardization of such a probe has yet been carried out. This research establishes the relationship between fiber separation distance and PPG signal, and between fiber core width and PPG signal. An ideal setup is suggested: 1000-μm fibers at a separation distance of 3 to 3.5 mm, which was found to produce signals around 0.35 V in amplitude with a low variation coefficient.

  20. Laboratory measurement of the absorption coefficient of riboflavin for ultraviolet light (365 nm).

    PubMed

    Iseli, Hans Peter; Popp, Max; Seiler, Theo; Spoerl, Eberhard; Mrochen, Michael

    2011-03-01

    Corneal cross-linking (CXL) is an increasingly used treatment technique for stabilizing the cornea in keratoconus. Cross-linking (polymerization) between collagen fibrils is induced by riboflavin (vitamin B2) and ultraviolet light (365 nm). Although reported to reach a constant value at higher riboflavin concentrations, the Lambert-Beer law predicts a linear increase in the absorption coefficient. This work was carried out to determine absorption behavior at different riboflavin concentrations and to further investigate the purported plateau absorption coefficient value of riboflavin and to identify possible bleaching effects. The Lambert-Beer law was used to calculate the absorption coefficient at various riboflavin concentrations. The following investigated concentrations of riboflavin solutions were prepared using a mixture of 0.5% riboflavin and 20% Dextran T500 dissolved in 0.9% sodium chloride solution: 0%, 0.02%, 0.03%, 0.04%, 0.05%, 0.06%, 0.08%, 0.1%, 0.2%, 0.3%, 0.4%, and 0.5%, and were investigated with and without aperture plate implementation. An additional test series measured the transmitted power at selected riboflavin concentrations over time. In diluted solutions, a linear correlation exists between the absorption coefficient and riboflavin concentration. The absorption coefficient reaches a plateau, but this occurs at a higher riboflavin concentration (0.1%) than previously reported (just above 0.04%). Transmitted light power increases over time, indicating a bleaching effect of riboflavin. The riboflavin concentration can be effectively varied as a treatment parameter in a considerably broader range than previously thought. Copyright 2011, SLACK Incorporated.

  1. Scanning optical microscope with long working distance objective

    DOEpatents

    Cloutier, Sylvain G.

    2010-10-19

    A scanning optical microscope, including: a light source to generate a beam of probe light; collimation optics to substantially collimate the probe beam; a probe-result beamsplitter; a long working-distance, infinity-corrected objective; scanning means to scan a beam spot of the focused probe beam on or within a sample; relay optics; and a detector. The collimation optics are disposed in the probe beam. The probe-result beamsplitter is arranged in the optical paths of the probe beam and the resultant light from the sample. The beamsplitter reflects the probe beam into the objective and transmits resultant light. The long working-distance, infinity-corrected objective is also arranged in the optical paths of the probe beam and the resultant light. It focuses the reflected probe beam onto the sample, and collects and substantially collimates the resultant light. The relay optics are arranged to relay the transmitted resultant light from the beamsplitter to the detector.

  2. Parallel Information Processing (Image Transmission Via Fiber Bundle and Multimode Fiber

    NASA Technical Reports Server (NTRS)

    Kukhtarev, Nicholai

    2003-01-01

    Growing demand for visual, user-friendly representation of information inspires search for the new methods of image transmission. Currently used in-series (sequential) methods of information processing are inherently slow and are designed mainly for transmission of one or two dimensional arrays of data. Conventional transmission of data by fibers requires many fibers with array of laser diodes and photodetectors. In practice, fiber bundles are also used for transmission of images. Image is formed on the fiber-optic bundle entrance surface and each fiber transmits the incident image to the exit surface. Since the fibers do not preserve phase, only 2D intensity distribution can be transmitted in this way. Each single mode fiber transmit only one pixel of an image. Multimode fibers may be also used, so that each mode represent different pixel element. Direct transmission of image through multimode fiber is hindered by the mode scrambling and phase randomization. To overcome these obstacles wavelength and time-division multiplexing have been used, with each pixel transmitted on a separate wavelength or time interval. Phase-conjugate techniques also was tested in, but only in the unpractical scheme when reconstructed image return back to the fiber input end. Another method of three-dimensional imaging over single mode fibers was demonstrated in, using laser light of reduced spatial coherence. Coherence encoding, needed for a transmission of images by this methods, was realized with grating interferometer or with the help of an acousto-optic deflector. We suggest simple practical holographic method of image transmission over single multimode fiber or over fiber bundle with coherent light using filtering by holographic optical elements. Originally this method was successfully tested for the single multimode fiber. In this research we have modified holographic method for transmission of laser illuminated images over commercially available fiber bundle (fiber endoscope, or fiberscope).

  3. Smartphone Based Platform for Colorimetric Sensing of Dyes

    NASA Astrophysics Data System (ADS)

    Dutta, Sibasish; Nath, Pabitra

    We demonstrate the working of a smartphone based optical sensor for measuring absorption band of coloured dyes. By integration of simple laboratory optical components with the camera unit of the smartphone we have converted it into a visible spectrometer with a pixel resolution of 0.345 nm/pixel. Light from a broadband optical source is allowed to transmit through a specific dye solution. The transmitted light signal is captured by the camera of the smartphone. The present sensor is inexpensive, portable and light weight making it an ideal handy sensor suitable for different on-field sensing.

  4. 50 CFR 600.730 - Facilitation of enforcement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light... your vessel instantly.” (Period (.) means a short flash of light; dash (-) means a long flash of light... authorized officer using loudhailer, radiotelephone, flashing light signal, or other means constitutes prima...

  5. 50 CFR 600.730 - Facilitation of enforcement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light... your vessel instantly.” (Period (.) means a short flash of light; dash (-) means a long flash of light... authorized officer using loudhailer, radiotelephone, flashing light signal, or other means constitutes prima...

  6. Novel Monitoring Techniques for Characterizing Frictional Interfaces in the Laboratory

    PubMed Central

    Selvadurai, Paul A.; Glaser, Steven D.

    2015-01-01

    A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA) interface in the laboratory. The film has structural health monitoring (SHM) applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM) to compare normal stress profiles. Experimental measurements of the normal stress profiles were within −7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light) of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa. PMID:25923930

  7. Soil transmitted helminths and schistosoma mansoni infections among school children in zarima town, northwest Ethiopia

    PubMed Central

    2011-01-01

    Background In Ethiopia, because of low quality drinking water supply and latrine coverage, helminths infections are the second most predominant causes of outpatient morbidity. Indeed, there is a scarcity of information on the prevalence of soil transmitted helminths and Schistosomiasis in Ethiopia, special in study area. Therefore, the aim of this study was to determine the prevalence and associated risk factors of soil transmitted helminths and intestinal Schistosomiasis. Methods Cross-sectional study was conducted among 319 school children of Zarima town from April 1 to May 25, 2009. A pre-tested structured questionnaire was used to collect socio-demographic data and possible risk factors exposure. Early morning stool samples were collected and a Kato Katz semi concentration technique was used to examine and count parasitic load by compound light microscope. Data entry and analysis was done using SPSS-15 version and p-value < 0.05 considered statistically significant. Results Out of 319 study subjects, 263 (82.4%) of the study participants infected with one or more parasites. From soil transmitted helminths, Ascaris lumbricoides was the predominant isolate (22%) followed by Hookworms (19%) and Trichuris trichiura (2.5%). Schistosoma mansoni was also isolated in 37.9% of the study participants. Hookworm and S. mansoni infections showed statistically significant associations with shoe wearing and swimming habit of school children, respectively. Conclusion Prevalence of soil transmitted helminths (STH) and S.mansoni was high and the diseases were still major health problem in the study area which alerts public health intervention as soon as possible. PMID:21740589

  8. Optical control of resonant light transmission for an atom-cavity system

    NASA Astrophysics Data System (ADS)

    Sharma, Arijit; Ray, Tridib; Sawant, Rahul V.; Sheikholeslami, G.; Rangwala, S. A.; Budker, D.

    2015-04-01

    We demonstrate the manipulation of transmitted light through an optical Fabry-Pérot cavity, built around a spectroscopy cell containing enriched rubidium vapor. Light resonant with the 87RbD2 (F =2 ,F =1 ) ↔F' manifold is controlled by the transverse intersection of the cavity mode by another resonant light beam. The cavity transmission can be suppressed or enhanced depending on the coupling of atomic states due to the intersecting beams. The extreme manifestation of the cavity-mode control is the precipitous destruction (negative logic switching) or buildup (positive logic switching) of the transmitted light intensity on intersection of the transverse control beam with the cavity mode. Both the steady-state and transient responses are experimentally investigated. The mechanism behind the change in cavity transmission is discussed in brief.

  9. Method and apparatus for free-space quantum key distribution in daylight

    DOEpatents

    Hughes, Richard J.; Buttler, William T.; Lamoreaux, Steve K.; Morgan, George L.; Nordholt, Jane E.; Peterson, C. Glen; Kwiat, Paul G.

    2004-06-08

    A quantum cryptography apparatus securely generates a key to be used for secure transmission between a sender and a receiver connected by an atmospheric transmission link. A first laser outputs a timing bright light pulse; other lasers output polarized optical data pulses after having been enabled by a random bit generator. Output optics transmit output light from the lasers that is received by receiving optics. A first beam splitter receives light from the receiving optics, where a received timing bright light pulse is directed to a delay circuit for establishing a timing window for receiving light from the lasers and where an optical data pulse from one of the lasers has a probability of being either transmitted by the beam splitter or reflected by the beam splitter. A first polarizer receives transmitted optical data pulses to output one data bit value and a second polarizer receives reflected optical data pulses to output a second data bit value. A computer receives pulses representing receipt of a timing bright timing pulse and the first and second data bit values, where receipt of the first and second data bit values is indexed by the bright timing pulse.

  10. Self-tuning method for monitoring the density of a gas vapor component using a tunable laser

    DOEpatents

    Hagans, Karla; Berzins, Leon; Galkowski, Joseph; Seng, Rita

    1996-01-01

    The present invention relates to a vapor density monitor and laser atomic absorption spectroscopy method for highly accurate, continuous monitoring of vapor densities, composition, flow velocity, internal and kinetic temperatures and constituent distributions. The vapor density monitor employs a diode laser, preferably of an external cavity design. By using a diode laser, the vapor density monitor is significantly less expensive and more reliable than prior art vapor density monitoring devices. In addition, the compact size of diode lasers enables the vapor density monitor to be portable. According to the method of the present invention, the density of a component of a gas vapor is calculated by tuning the diode laser to a frequency at which the amount of light absorbed by the component is at a minimum or a maximum within about 50 MHz of that frequency. Laser light from the diode laser is then transmitted at the determined frequency across a predetermined pathlength of the gas vapor. By comparing the amount of light transmitted by the diode laser to the amount of light transmitted after the laser light passes through the gas vapor, the density of the component can be determined using Beer's law.

  11. Self-tuning method for monitoring the density of a gas vapor component using a tunable laser

    DOEpatents

    Hagans, K.; Berzins, L.; Galkowski, J.; Seng, R.

    1996-08-27

    The present invention relates to a vapor density monitor and laser atomic absorption spectroscopy method for highly accurate, continuous monitoring of vapor densities, composition, flow velocity, internal and kinetic temperatures and constituent distributions. The vapor density monitor employs a diode laser, preferably of an external cavity design. By using a diode laser, the vapor density monitor is significantly less expensive and more reliable than prior art vapor density monitoring devices. In addition, the compact size of diode lasers enables the vapor density monitor to be portable. According to the method of the present invention, the density of a component of a gas vapor is calculated by tuning the diode laser to a frequency at which the amount of light absorbed by the component is at a minimum or a maximum within about 50 MHz of that frequency. Laser light from the diode laser is then transmitted at the determined frequency across a predetermined pathlength of the gas vapor. By comparing the amount of light transmitted by the diode laser to the amount of light transmitted after the laser light passes through the gas vapor, the density of the component can be determined using Beer`s law. 6 figs.

  12. Laser Doppler flowmetry in endodontics: a review.

    PubMed

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  13. Investigation of interfacial fracture behavior on injection molded parts

    NASA Astrophysics Data System (ADS)

    Fischer, Matthieu; Ausias, Gilles; Kuehnert, Ines

    2016-03-01

    In this study the interfacial morphology of different polymers joined by various assembly injection molding (AIM) technologies were discussed. Melt streams were injected successively using tools with core-back or rotation techniques. To compare bulk specimen strength and weld line strength, the fracture behavior of different specimen scales and thin sections were investigated. An in-situ SEM tensile test and a new thin section testing device which is used in polarized (transmitted) light microscopy were used to observe specimen failure. The effects of processing on spherulitic structures were linked to bonding strength and mechanical properties.

  14. Spatial-spectral characterization of focused spatially chirped broadband laser beams.

    PubMed

    Greco, Michael J; Block, Erica; Meier, Amanda K; Beaman, Alex; Cooper, Samuel; Iliev, Marin; Squier, Jeff A; Durfee, Charles G

    2015-11-20

    Proper alignment is critical to obtain the desired performance from focused spatially chirped beams, for example in simultaneous spatial and temporal focusing (SSTF). We present a simple technique for inspecting the beam paths and focusing conditions for the spectral components of a broadband beam. We spectrally resolve the light transmitted past a knife edge as it was scanned across the beam at several axial positions. The measurement yields information about spot size, M2, and the propagation paths of different frequency components. We also present calculations to illustrate the effects of defocus aberration on SSTF beams.

  15. The microscopes of Antoni van Leeuwenhoek.

    PubMed

    van Zuylen, J

    1981-03-01

    The seventeenth-century Dutch microscopist, Antoni van Leeuwenhoek, was the first man to make a protracted study of microscopical objects, and, unlike his contemporary Robert Hooke, he viewed by transmitted light. Leeuwenhoek made over 500 of his own, curious, simple microscopes, but now only nine are known to exist. The exact nature of the lenses Leeuwenhoek made, has for long been a puzzle. The existing microscopes have now been examined in detail, and their optical characteristics measured and tabulated. It is proposed that the lens of highest magnification, x 266, was made using a special blown bubble technique.

  16. DISCRIMINATING BETWEEN CLOUDY, HAZY, AND CLEAR SKY EXOPLANETS USING REFRACTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Misra, Amit K.; Meadows, Victoria S.

    2014-11-01

    We propose a method to distinguish between cloudy, hazy, and clear sky (free of clouds and hazes) exoplanet atmospheres that could be applicable to upcoming large aperture space- and ground-based telescopes such as the James Webb Space Telescope (JWST) and the European Extremely Large Telescope (E-ELT). These facilities will be powerful tools for characterizing transiting exoplanets, but only after a considerable amount of telescope time is devoted to a single planet. A technique that could provide a relatively rapid means of identifying haze-free targets (which may be more valuable targets for characterization) could potentially increase the science return for thesemore » telescopes. Our proposed method utilizes broadband observations of refracted light in the out-of-transit spectrum. Light refracted through an exoplanet atmosphere can lead to an increase of flux prior to ingress and subsequent to egress. Because this light is transmitted at pressures greater than those for typical cloud and haze layers, the detection of refracted light could indicate a cloud- or haze-free atmosphere. A detection of refracted light could be accomplished in <10 hr for Jovian exoplanets with JWST and <5 hr for super-Earths/mini-Neptunes with E-ELT. We find that this technique is most effective for planets with equilibrium temperatures between 200 and 500 K, which may include potentially habitable planets. A detection of refracted light for a potentially habitable planet would strongly suggest the planet was free of a global cloud or haze layer, and therefore a promising candidate for follow-up observations.« less

  17. Generation of low-divergence laser beams

    DOEpatents

    Kronberg, James W.

    1993-01-01

    Apparatus for transforming a conventional beam of coherent light, having a Gaussian energy distribution and relatively high divergence, into a beam in which the energy distribution approximates a single, non-zero-order Bessel function and which therefore has much lower divergence. The apparatus comprises a zone plate having transmitting and reflecting zones defined by the pattern of light interference produced by the combination of a beam of coherent light with a Gaussian energy distribution and one having such a Bessel distribution. The interference pattern between the two beams is a concentric array of multiple annuli, and is preferably recorded as a hologram. The hologram is then used to form the transmitting and reflecting zones by photo-etching portions of a reflecting layer deposited on a plate made of a transmitting material. A Bessel beam, containing approximately 50% of the energy of the incident beam, is produced by passing a Gaussian beam through such a Bessel zone plate. The reflected beam, also containing approximately 50% of the incident beam energy and having a Bessel energy distribution, can be redirected in the same direction and parallel to the transmitted beam. Alternatively, a filter similar to the Bessel zone plate can be placed within the resonator cavity of a conventional laser system having a front mirror and a rear mirror, preferably axially aligned with the mirrors and just inside the front mirror to generate Bessel energy distribution light beams at the laser source.

  18. Infrared system for monitoring movement of objects

    DOEpatents

    Valentine, Kenneth H.; Falter, Diedre D.; Falter, Kelly G.

    1991-01-01

    A system for monitoring moving objects, such as the flight of honeybees and other insects, using a pulsed laser light source. This system has a self-powered micro-miniaturized transmitting unit powered, in the preferred embodiment, with an array solar cells. This transmitting unit is attached to the object to be monitored. These solar cells provide current to a storage energy capacitor to produce, for example, five volts for the operation of the transmitter. In the simplest embodiment, the voltage on the capacitor operates a pulse generator to provide a pulsed energizing signal to one or more very small laser diodes. The pulsed light is then received at a receiving base station using substantially standard means which converts the light to an electrical signal for processing in a microprocessor to create the information as to the movement of the object. In the case of a unit for monitoring honeybees and other insects, the transmitting unit weighs less than 50 mg, and has a size no larger than 1.times.3.times.5 millimeters. Also, the preferred embodiment provides for the coding of the light to uniquely identify the particular transmitting unit that is being monitored. A "wake-up" circuit is provided in the preferred embodiment whereby there is no transmission until the voltage on the capacitor has exceeded a pre-set threshold. Various other uses of the motion-detection system are described.

  19. Infrared system for monitoring movement of objects

    DOEpatents

    Valentine, K.H.; Falter, D.D.; Falter, K.G.

    1991-04-30

    A system is described for monitoring moving objects, such as the flight of honeybees and other insects, using a pulsed laser light source. This system has a self-powered micro-miniaturized transmitting unit powered, in the preferred embodiment, with an array of solar cells. This transmitting unit is attached to the object to be monitored. These solar cells provide current to a storage energy capacitor to produce, for example, five volts for the operation of the transmitter. In the simplest embodiment, the voltage on the capacitor operates a pulse generator to provide a pulsed energizing signal to one or more very small laser diodes. The pulsed light is then received at a receiving base station using substantially standard means which converts the light to an electrical signal for processing in a microprocessor to create the information as to the movement of the object. In the case of a unit for monitoring honeybees and other insects, the transmitting unit weighs less than 50 mg, and has a size no larger than 1[times]3[times]5 millimeters. Also, the preferred embodiment provides for the coding of the light to uniquely identify the particular transmitting unit that is being monitored. A wake-up' circuit is provided in the preferred embodiment whereby there is no transmission until the voltage on the capacitor has exceeded a pre-set threshold. Various other uses of the motion-detection system are described. 4 figures.

  20. Theory of CW lidar aerosol backscatter measurements and development of a 2.1 microns solid-state pulsed laser radar for aerosol backscatter profiling

    NASA Technical Reports Server (NTRS)

    Kavaya, Michael J.; Henderson, Sammy W.; Frehlich, R. G.

    1991-01-01

    The performance and calibration of a focused, continuous wave, coherent detection CO2 lidar operated for the measurement of atmospheric backscatter coefficient, B(m), was examined. This instrument functions by transmitting infrared (10 micron) light into the atmosphere and collecting the light which is scattered in the rearward direction. Two distinct modes of operation were considered. In volume mode, the scattered light energy from many aerosols is detected simultaneously, whereas in the single particle mode (SPM), the scattered light energy from a single aerosol is detected. The analysis considered possible sources of error for each of these two cases, and also considered the conditions where each technique would have superior performance. The analysis showed that, within reasonable assumptions, the value of B(m) could be accurately measured by either the VM or the SPM method. The understanding of the theory developed during the analysis was also applied to a pulsed CO2 lidar. Preliminary results of field testing of a solid state 2 micron lidar using a CW oscillator is included.

  1. Control of liquid crystal molecular orientation using ultrasound vibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taniguchi, Satoki; Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321; Koyama, Daisuke

    2016-03-07

    We propose a technique to control the orientation of nematic liquid crystals using ultrasound and investigate the optical characteristics of the oriented samples. An ultrasonic liquid crystal cell with a thickness of 5–25 μm and two ultrasonic lead zirconate titanate transducers was fabricated. By exciting the ultrasonic transducers, the flexural vibration modes were generated on the cell. An acoustic radiation force to the liquid crystal layer was generated, changing the molecular orientation and thus the light transmission. By modulating the ultrasonic driving frequency and voltage, the spatial distribution of the molecular orientation of the liquid crystals could be controlled. The distributionmore » of the transmitted light intensity depends on the thickness of the liquid crystal layer because the acoustic field in the liquid crystal layer is changed by the orientational film.« less

  2. Non-invasive, photonics-based diagnostic, imaging, monitoring, and light delivery techniques for the recognition, quantification and treatment of malignant and chronic inflammatory conditions

    NASA Astrophysics Data System (ADS)

    Davies, N.; Davies-Shaw, D.; Shaw, J. D.

    2007-02-01

    We report firsthand on innovative developments in non-invasive, biophotonic techniques for a wide range of diagnostic, imaging and treatment options, including the recognition and quantification of cancerous, pre-cancerous cells and chronic inflammatory conditions. These techniques have benefited from the ability to target the affected site by both monochromatic light and broad multiple wavelength spectra. The employment of such wavelength or color-specific properties embraces the fluorescence stimulation of various photosensitizing drugs, and the instigation and detection of identified fluorescence signatures attendant upon laser induced fluorescence (LIF) phenomena as transmitted and propagated by precancerous, cancerous and normal tissue. In terms of tumor imaging and therapeutic and treatment options, we have exploited the abilities of various wavelengths to penetrate to different depths, through different types of tissues, and have explored quantifiable absorption and reflection characteristics upon which diagnostic assumptions can be reliably based and formulated. These biophotonic-based diagnostic, sensing and imaging techniques have also benefited from, and have been further enhanced by, the integrated ability to provide various power levels to be employed at various stages in the procedure. Applications are myriad, including non-invasive, non destructive diagnosis of in vivo cell characteristics and functions; light-based tissue analysis; real-time monitoring and mapping of brain function and of tumor growth; real time monitoring of the surgical completeness of tumor removal during laser-imaged/guided brain resection; diagnostic procedures based on fluorescence life-time monitoring, the monitoring of chronic inflammatory conditions (including rheumatoid arthritis), and continuous blood glucose monitoring in the control of diabetes.

  3. A power allocation method for 2 × 2 VLC-MIMO indoor communication

    NASA Astrophysics Data System (ADS)

    Dai, Mingjun; Yuan, Jing; Feng, Renhai; Wang, Hui; Chen, Bin; Lin, Xiaohui

    2016-08-01

    Visible light communication (VLC) has been a promising field of optical communications which focuses on visible light spectrum that humans can see. Unlike existing studies which mainly discuss point-to-point communication, in this paper, we consider a VLC network, in particular a 2 × 2 system. Our focus is on dealing with interference in this network. The objective is to maximize the signal to interference plus noise ratio (SINR) of one receiver for a given SINR of another receiver. We formulate a power allocation optimization problem to deal with such interference, and introduce dichotomy to solve this optimization problem. Simulation results have twofold meaning: First, SINR_1 increases with the growth of SINR_2, which are the SINR of the two receivers, respectively. Second, our proposed scheme outperforms the classical time-division multiple access technique in terms of transmit powers of both light sources when the data rate for these two schemes are set to be identical for each user, respectively.

  4. Tuning the photon statistics of a strongly coupled nanophotonic system

    NASA Astrophysics Data System (ADS)

    Dory, Constantin; Fischer, Kevin A.; Müller, Kai; Lagoudakis, Konstantinos G.; Sarmiento, Tomas; Rundquist, Armand; Zhang, Jingyuan L.; Kelaita, Yousif; Sapra, Neil V.; Vučković, Jelena

    2017-02-01

    We investigate the dynamics of single- and multiphoton emission from detuned strongly coupled systems based on the quantum-dot-photonic-crystal resonator platform. Transmitting light through such systems can generate a range of nonclassical states of light with tunable photon counting statistics due to the nonlinear ladder of hybridized light-matter states. By controlling the detuning between emitter and resonator, the transmission can be tuned to strongly enhance either single- or two-photon emission processes. Despite the strongly dissipative nature of these systems, we find that by utilizing a self-homodyne interference technique combined with frequency filtering we are able to find a strong two-photon component of the emission in the multiphoton regime. In order to explain our correlation measurements, we propose rate equation models that capture the dominant processes of emission in both the single- and multiphoton regimes. These models are then supported by quantum-optical simulations that fully capture the frequency filtering of emission from our solid-state system.

  5. Visible light communication technology for fine-grained indoor localization

    NASA Astrophysics Data System (ADS)

    Vieira, M.; Vieira, M. A.; Louro, P.; Fantoni, A.; Vieira, P.

    2018-02-01

    This paper focuses on designing and analysing a visible light based communication and positioning system. The indoor positioning system uses trichromatic white Light Emitting Diodes (LEDs), both for illumination purposes and as transmitters, and an optical processor, based on a-SiC:H technology, as mobile receiver. On-Off Keying (OOK) modulation scheme is used, proving a good trade-off between system performance and implementation complexity. In the following, the relationship between the transmitted data and the received output levels is decoded. LED bulbs work as transmitters, sending information together with different identifiers, IDs, related to their physical locations. Square and diamond topologies for the unit cell are analyzed, and a 2D localization design, demonstrated by a prototype implementation, is presented. Fine-grained indoor localization is tested. The received signal is used in coded multiplexing techniques for supporting communications and navigation concomitantly on the same channel. The location and motion information is found by mapping the position and estimating the location areas.

  6. Oximeter for reliable clinical determination of blood oxygen saturation in a fetus

    DOEpatents

    Robinson, Mark R.; Haaland, David M.; Ward, Kenneth J.

    1996-01-01

    With the crude instrumentation now in use to continuously monitor the status of the fetus at delivery, the obstetrician and labor room staff not only over-recognize the possibility of fetal distress with the resultant rise in operative deliveries, but at times do not identify fetal distress which may result in preventable fetal neurological harm. The invention, which addresses these two basic problems, comprises a method and apparatus for non-invasive determination of blood oxygen saturation in the fetus. The apparatus includes a multiple frequency light source which is coupled to an optical fiber. The output of the fiber is used to illuminate blood containing tissue of the fetus. In the preferred embodiment, the reflected light is transmitted back to the apparatus where the light intensities are simultaneously detected at multiple frequencies. The resulting spectrum is then analyzed for determination of oxygen saturation. The analysis method uses multivariate calibration techniques that compensate for nonlinear spectral response, model interfering spectral responses and detect outlier data with high sensitivity.

  7. Design and measurement technique of surface-enhanced Raman scattering for detection of bisphenol A

    NASA Astrophysics Data System (ADS)

    Abu Bakar, Norhayati; Mat Salleh, Muhamad; Umar, Akrajas Ali; Shapter, Joseph George

    2017-06-01

    Surface-enhanced Raman scattering (SERS) is a highly sensitive measurement technique that provides Raman peaks at different Raman shift for different molecule structures. The SERS sensor is potentially used to detect food contamination and monitor environmental pollutants. A self-developed SERS system for specific analysis with low development cost is a challenging issue. This study attempts to develop a simple SERS sensor system for detection of bisphenol A (BPA) molecule using SERS substrate of silver nanoplate film. A SERS sensor system was developed, consisting of a light source to excite analyte molecules, Inphotonic Raman probe, sensor chamber and spectrophotometer as an analyser system. A duplex fibre optic is used to transmit light from the source to the probe and from the probe to the spectrophotometer. For SERS measurement, BPA detection was done by comparing the Raman signal spectra of the BPA on the quartz substrate and BPA on the silver nanoplate film. This SERS sensor successfully sensed BPA with SERS enhancement factor (EF) 5.55  ×  103 and a detection limit of BPA concentration at 1 mM.

  8. Orbital angular momentum in four channel spatial domain multiplexing system for multi-terabit per second communication architectures

    NASA Astrophysics Data System (ADS)

    Murshid, Syed H.; Muralikrishnan, Hari P.; Kozaitis, Samuel P.

    2012-06-01

    Bandwidth increase has always been an important area of research in communications. A novel multiplexing technique known as Spatial Domain Multiplexing (SDM) has been developed at the Optronics Laboratory of Florida Institute of Technology to increase the bandwidth to T-bits/s range. In this technique, space inside the fiber is used effectively to transmit up to four channels of same wavelength at the same time. Experimental and theoretical analysis shows that these channels follow independent helical paths inside the fiber without interfering with each other. Multiple pigtail laser sources of exactly the same wavelength are used to launch light into a single carrier fiber in a fashion that resulting channels follow independent helical trajectories. These helically propagating light beams form optical vortices inside the fiber and carry their own Orbital Angular Momentum (OAM). The outputs of these beams appear as concentric donut shaped rings when projected on a screen. This endeavor presents the experimental outputs and simulated results for a four channel spatially multiplexed system effectively increasing the system bandwidth by a factor of four.

  9. Polarization interferometry for real-time spectroscopic plasmonic sensing.

    PubMed

    Otto, Lauren M; Mohr, Daniel A; Johnson, Timothy W; Oh, Sang-Hyun; Lindquist, Nathan C

    2015-03-07

    We present quantitative, spectroscopic polarization interferometry phase measurements on plasmonic surfaces for sensing applications. By adding a liquid crystal variable wave plate in our beam path, we are able to measure phase shifts due to small refractive index changes on the sensor surface. By scanning in a quick sequence, our technique is extended to demonstrate real-time measurements. While this optical technique is applicable to different sensor geometries-e.g., nanoparticles, nanogratings, or nanoapertures-the plasmonic sensors we use here consist of an ultrasmooth gold layer with buried linear gratings. Using these devices and our phase measurement technique, we calculate a figure of merit that shows improvement over measuring only surface plasmon resonance shifts from a reflected intensity spectrum. To demonstrate the general-purpose versatility of our phase-resolved measurements, we also show numerical simulations with another common device architecture: periodic plasmonic slits. Since our technique inherently measures both the intensity and phase of the reflected or transmitted light simultaneously, quantitative sensor device characterization is possible.

  10. Finding a Cold Needle in a Warm Haystack: Infrared Imaging Applied to Locating Cryocooled Crystals in Loops

    NASA Technical Reports Server (NTRS)

    Snell, E. H.; vanderWoerd, M. J.; Miller, M. D.; Deacon, A. M.

    2004-01-01

    We demonstrate the use of inbred imaging to locate crystals mounted in cryoloops and cryopreserved in a nitrogen gas stream at 100K. In the home laboratory crystals are clearly seen in the infrared images with light transmitting through the sample while irradiating the crystal from behind, and with illumination from a direction perpendicular to the direction of view. The crystals transmit and reflect infrared radiation differently from the surrounding mother liquor and loop. Because of differences in contrast between crystals and their surrounding mother liquor, it is possible to clearly identify the crystal position. In use at the synchrotron, with robotically mounted crystals the small depth of field of the lens required the recording of multiple images at different focal points. Image processing techniques were then used to produce a clear image of the crystal. The resulting infrared images and intensity profiles show that infrared imaging can be a powerful complement to visual imaging in locating crystals in cryocooled loops.

  11. Controllable light diffraction in woodpile photonic crystals filled with liquid crystal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Chih-Hua; Zeng, Hao; Wiersma, Diederik S.

    2015-01-12

    An approach to switching between different patterns of light beams transmitted through the woodpile photonic crystals filled with liquid crystals is proposed. The phase transition between the nematic and isotropic liquid crystal states leads to an observable variation of the spatial pattern transmitted through the photonic structure. The transmission profiles in the nematic phase also show polarization sensibility due to refractive index dependence on the field polarization. The experimental results are consistent with a numerical calculation by Finite Difference Time Domain method.

  12. 76 FR 17613 - Aviation Service Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ...) regarding audio visual warning systems (AVWS). OCAS, Inc. installs such technology under the trademark OCAS... frequencies to activate obstruction lighting and transmit audible warnings to aircraft on a potential... transmit audible warnings to pilots. We seek comment on operational, licensing, eligibility and equipment...

  13. [Prevalence and intensity of infection by soil-transmitted helminths and prevalence of malaria among schoolchildren in El Salvador].

    PubMed

    Sorto, Óscar René; Portillo, Alexandra Manoella; Aragón, Miguel Ángel; Saboyá, Martha Idalí; Ade, María Paz; Minero, Miguel Ángel; Hernández, Marta Alicia; Mena, Amada Gloria; Peña, Rodolfo; Mejía, Victor Manuel; Carter, Keith

    2015-01-01

    El Salvador does not have recent data on the prevalence of infection with soil-transmitted helminths among children aged under 15 years of age. As one of the countries in the Americas that reports few malaria cases, eradication of this disease from El Salvador is considered to be feasible. To determine the prevalence and intensity of infection by soil-transmitted helminths, as well as the prevalence of Plasmodium spp. in schoolchildren aged 8-10. A cross-sectional study was carried out in each of the five eco-epidemiological zones of the country (coastal plain, central basin, volcanic range, coastal range and mountain zone). In all 1,325 students we studied the presence of geohelminthiasis, with 152 of them also being tested for malaria. The Kato-Katz technique was used to detect geohelminths while diagnosis of malaria was performed using the rapid diagnostic test, microscopy and polymerase chain reaction. The overall prevalence of geohelminthiasis was 7.9% (95%CI 6.6-9.5%). Values for the five eco-epidemiological zones were as follows: coastal plain, 14.9% (95%CI 10.9-19.7%); central plateau, 9.4% (95%CI 6.5-13.3%); volcanic range, 6.6% (95%CI 4.2-10.5%); coastal range, 5.9% (95%CI 3.8-9.4%), and mountain zone, 2.6% (95%CI 1.4-5.7%). The overall rate of high intensity infection with any of the geohelminth species was 0.3%. No schoolchildren were found infected with Plasmodium spp. by any of the three diagnostic techniques used. Prevalence of geohelminths was low and Trichuris trichiura was the predominant species. Intensity of infection with any of the species of geohelminths was light (<1%). The risk factors associated with infection by soil-transmitted helminths were defecation in the open air, being barefoot and living in coastal areas.

  14. 50 CFR 300.5 - Facilitation of enforcement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light..., flashing light, flags, whistle, horn or other means constitutes prima facie evidence of the offense of... International Code of Signals, may be sent by flashing light by an enforcement unit when conditions do not allow...

  15. 50 CFR 300.5 - Facilitation of enforcement.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... transmitted by flashing light directed at the vessel signaled. USCG units will normally use the flashing light..., flashing light, flags, whistle, horn or other means constitutes prima facie evidence of the offense of... International Code of Signals, may be sent by flashing light by an enforcement unit when conditions do not allow...

  16. Frequency-Dependent Blanking with Digital Linear Chirp Waveform Synthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerry, Armin Walter; Andrews, John M.

    2014-07-01

    Wideband radar systems, especially those that operate at lower frequencies such as VHF and UHF, are often restricted from transmitting within or across specific frequency bands in order to prevent interference to other spectrum users. Herein we describe techniques for notching the transmitted spectrum of a generated and transmitted radar waveform. The notches are fully programmable as to their location, and techniques are given that control the characteristics of the notches.

  17. Ultracompact beam splitters based on plasmonic nanoslits

    PubMed Central

    Zhou, Chuanhong; Kohli, Punit

    2011-01-01

    An ultracompact plasmonic beam splitter is theoretically and numerically investigated. The splitter consists of a V-shaped nanoslit in metal films. Two groups of nanoscale metallic grooves inside the slit (A) and at the small slit opening (B) are investigated. We show that there are two energy channels guiding light out by the splitter: the optical and the plasmonic channels. Groove A is used to couple incident light into the plasmonic channel. Groove B functions as a plasmonic scatter. We demonstrate that the energy transfer through plasmonic path is dominant in the beam splitter. We find that more than four times the energy is transferred by the plasmonic channel using structures A and B. We show that the plasmonic waves scattered by B can be converted into light waves. These light waves redistribute the transmitted energy through interference with the field transmitted from the nanoslit. Therefore, different beam splitting effects are achieved by simply changing the interference conditions between the scattered waves and the transmitted waves. The impact of the width and height of groove B are also investigated. It is found that the plasmonic scattering of B is changed into light scattering with increase of the width and the height of B. These devices have potential applications in optical sampling, signal processing, and integrated optical circuits. PMID:21647248

  18. A portable smart phone-based plasmonic nanosensor readout platform that measures transmitted light intensities of nanosubstrates using an ambient light sensor.

    PubMed

    Fu, Qiangqiang; Wu, Ze; Xu, Fangxiang; Li, Xiuqing; Yao, Cuize; Xu, Meng; Sheng, Liangrong; Yu, Shiting; Tang, Yong

    2016-05-21

    Plasmonic nanosensors may be used as tools for diagnostic testing in the field of medicine. However, quantification of plasmonic nanosensors often requires complex and bulky readout instruments. Here, we report the development of a portable smart phone-based plasmonic nanosensor readout platform (PNRP) for accurate quantification of plasmonic nanosensors. This device operates by transmitting excitation light from a LED through a nanosubstrate and measuring the intensity of the transmitted light using the ambient light sensor of a smart phone. The device is a cylinder with a diameter of 14 mm, a length of 38 mm, and a gross weight of 3.5 g. We demonstrated the utility of this smart phone-based PNRP by measuring two well-established plasmonic nanosensors with this system. In the first experiment, the device measured the morphology changes of triangular silver nanoprisms (AgNPRs) in an immunoassay for the detection of carcinoembryonic antigen (CEA). In the second experiment, the device measured the aggregation of gold nanoparticles (AuNPs) in an aptamer-based assay for the detection of adenosine triphosphate (ATP). The results from the smart phone-based PNRP were consistent with those from commercial spectrophotometers, demonstrating that the smart phone-based PNRP enables accurate quantification of plasmonic nanosensors.

  19. "Colgate-Plus"--An Imperfect Light Pipe.

    ERIC Educational Resources Information Center

    Ouseph, P. J.

    1993-01-01

    Describes the effects when a clear toothbrush is used as total internally reflecting light pipe when attached to a laser. Several explanations are given describing the nonuniformity of the transmitted light resulting from surface and internal irregularities found in the toothbrush. (MVL)

  20. Development of a High Spectral Resolution Lidar (HSRL) Based on a Confocal Optical Filter for Aerosol Studies

    NASA Astrophysics Data System (ADS)

    Repasky, K. S.; Hoffman, D. S.; Reagan, J. A.; Carlsten, J.

    2010-12-01

    Aerosols are an important constituent in atmospheric composition affecting climate, weather, and air quality. Active remote sensing instruments provide tools for in-situ studies of atmospheric aerosols that can help understand the role of aerosols on the radiative forcing of the climate system. In this paper, the design and initial performance of a high spectral resolution lidar (HSRL) based on a unique confocal cavity for optically filtering the aerosol and molecular returns is presented. An injection seeded pulsed Nd:YAG laser with a fundamental and frequency doubled output is used as the laser transmitter for the HSRL. A small portion of fiber coupled injection seeded signal at 1064 nm is split before the laser oscillator and, after modulation using an acousto-optic modulator, is used to produce a discriminating signal for locking a confocal cavity that is resonant at the 1064 and 532 nm wavelengths to the injection seeded source. Light scattered in the atmosphere is collected using a commercial telescope. After the telescope, the 1064 nm light is split from the 532 nm light using a dielectric mirror with the 1064 nm light monitored using a PMT. The 532 nm light is launched into a multimode fiber. The output from the fiber is next incident on a beamsplitter with part of the light sent to a PMT to monitor the total return for the 532 nm channel. The light that passes through the beamsplitter is mode matched into a confocal optical cavity that allows the light scattered by the atmospheric aerosols to be transmitted while the light scattered from the atmospheric molecules is reflected. The transmitted light from the aerosol scattering is incident on a PMT while the reflected molecular signal is incident on a PMT. The transmission of the confocal cavity is monitored before and after the data collection using a continuous wave frequency doubled Nd:YAG laser that is fiber coupled. Data is collected and processed in the following manner. Each of the four voltage signals from the PMT’s are monitored using a high speed A/D card. The inversion of the 1064 nm return signal is completed using the Fernald inversion technique with the additional constraint of the aerosol optical depth. The HSRL 532 nm signal is inverted using a Rayleigh backscatter model along with the inversion techniques described by Shipley et al. (Applied Optics, V22, N23, 3716-3724, 1983) and Sroga et al. (Applied Optics, V22, N23, 3725-3732, 1983). This presentation will focus on the design of the confocal optical filter, the locking of the confocal optical filter to the laser transmitter, and the performance of the high spectral resolution channel at 532 nm. Data will be presented showing the molecular returns, the aerosol returns and the range resolved lidar ratio.

  1. Optical characterization of phase transitions in pure polymers and blends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mannella, Gianluca A.; Brucato, Valerio; La Carrubba, Vincenzo, E-mail: vincenzo.lacarrubba@unipa.it

    2015-12-17

    To study the optical properties of polymeric samples, an experimental apparatus was designed on purpose and set up. The sample is a thin film enclosed between two glass slides and a PTFE frame, with a very thin thermocouple placed on sample for direct temperature measurement. This sample holder was placed between two aluminum slabs, equipped with a narrow slit for optical measurements and with electrical resistances for temperature control. Sample was enlightened by a laser diode, whereas transmitted light was detected with a photodiode. Measurements were carried out on polyethylene-terephtalate (PET) and two different polyamides, tested as pure polymers andmore » blends. The thermal history imposed to the sample consisted in a rapid heating from ambient temperature to a certain temperature below the melting point, a stabilization period, and then a heating at constant rate. After a second stabilization period, the sample was cooled. The data obtained were compared with DSC measurements performed with the same thermal history. In correspondence with transitions detected via DSC (e.g. melting, crystallization and cold crystallization), the optical signal showed a steep variation. In particular, crystallization resulted in a rapid decrease of transmitted light, whereas melting gave up an increase of light transmitted by the sample. Further variations in transmitted light were recorded for blends, after melting: those results may be related to other phase transitions, e.g. liquid-liquid phase separation. All things considered, the apparatus can be used to get reliable data on phase transitions in polymeric systems.« less

  2. Generation of low-divergence laser beams

    DOEpatents

    Kronberg, J.W.

    1993-09-14

    Apparatus for transforming a conventional beam of coherent light, having a Gaussian energy distribution and relatively high divergence, into a beam in which the energy distribution approximates a single, non-zero-order Bessel function and which therefore has much lower divergence. The apparatus comprises a zone plate having transmitting and reflecting zones defined by the pattern of light interference produced by the combination of a beam of coherent light with a Gaussian energy distribution and one having such a Bessel distribution. The interference pattern between the two beams is a concentric array of multiple annuli, and is preferably recorded as a hologram. The hologram is then used to form the transmitting and reflecting zones by photo-etching portions of a reflecting layer deposited on a plate made of a transmitting material. A Bessel beam, containing approximately 50% of the energy of the incident beam, is produced by passing a Gaussian beam through such a Bessel zone plate. The reflected beam, also containing approximately 50% of the incident beam energy and having a Bessel energy distribution, can be redirected in the same direction and parallel to the transmitted beam. Alternatively, a filter similar to the Bessel zone plate can be placed within the resonator cavity of a conventional laser system having a front mirror and a rear mirror, preferably axially aligned with the mirrors and just inside the front mirror to generate Bessel energy distribution light beams at the laser source. 11 figures.

  3. Quantitative imaging and in situ concentration measurements of quantum dot nanomaterials in variably saturated porous media

    DOE PAGES

    Uyuşur, Burcu; Snee, Preston T.; Li, Chunyan; ...

    2016-01-01

    Knowledge of the fate and transport of nanoparticles in the subsurface environment is limited, as techniques to monitor and visualize the transport and distribution of nanoparticles in porous media and measure their in situ concentrations are lacking. To address these issues, we have developed a light transmission and fluorescence method to visualize and measure in situ concentrations of quantum dot (QD) nanoparticles in variably saturated environments. Calibration cells filled with sand as porous medium and various known water saturation levels and QD concentrations were prepared. By measuring the intensity of the light transmitted through porous media exposed to fluorescent lightmore » and by measuring the hue of the light emitted by the QDs under UV light exposure, we obtained simultaneously in situ measurements of water saturation and QD nanoparticle concentrations with high spatial and temporal resolutions. Water saturation was directly proportional to the light intensity. A linear relationship was observed between hue-intensity ratio values and QD concentrations for constant water saturation levels. Lastly, the advantages and limitations of the light transmission and fluorescence method as well as its implications for visualizing and measuring in situ concentrations of QDs nanoparticles in the subsurface environment are discussed.« less

  4. Comparison of quartz crystallographic preferred orientations identified with optical fabric analysis, electron backscatter and neutron diffraction techniques.

    PubMed

    Hunter, N J R; Wilson, C J L; Luzin, V

    2017-02-01

    Three techniques are used to measure crystallographic preferred orientations (CPO) in a naturally deformed quartz mylonite: transmitted light cross-polarized microscopy using an automated fabric analyser, electron backscatter diffraction (EBSD) and neutron diffraction. Pole figure densities attributable to crystal-plastic deformation are variably recognizable across the techniques, particularly between fabric analyser and diffraction instruments. Although fabric analyser techniques offer rapid acquisition with minimal sample preparation, difficulties may exist when gathering orientation data parallel with the incident beam. Overall, we have found that EBSD and fabric analyser techniques are best suited for studying CPO distributions at the grain scale, where individual orientations can be linked to their source grain or nearest neighbours. Neutron diffraction serves as the best qualitative and quantitative means of estimating the bulk CPO, due to its three-dimensional data acquisition, greater sample area coverage, and larger sample size. However, a number of sampling methods can be applied to FA and EBSD data to make similar approximations. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  5. Optical key system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagans, K.G.; Clough, R.E.

    2000-04-25

    An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam ofmore » light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.« less

  6. Optical key system

    DOEpatents

    Hagans, Karla G.; Clough, Robert E.

    2000-01-01

    An optical key system comprises a battery-operated optical key and an isolated lock that derives both its operating power and unlock signals from the correct optical key. A light emitting diode or laser diode is included within the optical key and is connected to transmit a bit-serial password. The key user physically enters either the code-to-transmit directly, or an index to a pseudorandom number code, in the key. Such person identification numbers can be retained permanently, or ephemeral. When a send button is pressed, the key transmits a beam of light modulated with the password information. The modulated beam of light is received by a corresponding optical lock with a photovoltaic cell that produces enough power from the beam of light to operate a password-screen digital logic. In one application, an acceptable password allows a two watt power laser diode to pump ignition and timing information over a fiberoptic cable into a sealed engine compartment. The receipt of a good password allows the fuel pump, spark, and starter systems to each operate. Therefore, bypassing the lock mechanism as is now routine with automobile thieves is pointless because the engine is so thoroughly disabled.

  7. Automated measurement of spatial preference in the open field test with transmitted lighting.

    PubMed

    Kulikov, Alexander V; Tikhonova, Maria A; Kulikov, Victor A

    2008-05-30

    New modification of the open field was designed to improve automation of the test. The main innovations were: (1) transmitted lighting and (2) estimation of probability to find pixels associated with an animal in the selected region of arena as an objective index of spatial preference. Transmitted (inverted) lighting significantly ameliorated the contrast between an animal and arena and allowed to track white animals with similar efficacy as colored ones. Probability as a measure of preference of selected region was mathematically proved and experimentally verified. A good correlation between probability and classic indices of spatial preference (number of region entries and time spent therein) was shown. The algorithm of calculation of probability to find pixels associated with an animal in the selected region was implemented in the EthoStudio software. Significant interstrain differences in locomotion and the central zone preference (index of anxiety) were shown using the inverted lighting and the EthoStudio software in mice of six inbred strains. The effects of arena shape (circle or square) and a novel object presence in the center of arena on the open field behavior in mice were studied.

  8. Mobile health-monitoring system through visible light communication.

    PubMed

    Tan, Yee-Yong; Chung, Wan-Young

    2014-01-01

    Promising development in the light emitting diode (LED) technology has spurred the interest to adapt LED for both illumination and data transmission. This has fostered the growth of interest in visible light communication (VLC), with on-going research to utilize VLC in various applications. This paper presents a mobile-health monitoring system, where healthcare information such as biomedical signals and patient information are transmitted via the LED lighting. A small and portable receiver module is designed and developed to be attached to the mobile device, providing a seamless monitoring environment. Three different healthcare information including ECG, PPG signals and HL7 text information is transmitted simultaneously, using a single channel VLC. This allows for a more precise and accurate monitoring and diagnosis. The data packet size is carefully designed, to transmit information in a minimal packet error rate. A comprehensive monitoring application is designed and developed through the use of a tablet computer in our study. Monitoring and evaluation such as heart rate and arterial blood pressure measurement can be performed concurrently. Real-time monitoring is demonstrated through experiment, where non-hazardous transmission method can be implemented alongside a portable device for better and safer healthcare service.

  9. Real-Time Label-Free Surface Plasmon Resonance Biosensing with Gold Nanohole Arrays Fabricated by Nanoimprint Lithography

    PubMed Central

    Martinez-Perdiguero, Josu; Retolaza, Aritz; Otaduy, Deitze; Juarros, Aritz; Merino, Santos

    2013-01-01

    In this work we present a surface plasmon resonance sensor based on enhanced optical transmission through sub-wavelength nanohole arrays. This technique is extremely sensitive to changes in the refractive index of the surrounding medium which result in a modulation of the transmitted light. The periodic gold nanohole array sensors were fabricated by high-throughput thermal nanoimprint lithography. Square periodic arrays with sub-wavelength hole diameters were obtained and characterized. Using solutions with known refractive index, the array sensitivities were obtained. Finally, protein absorption was monitored in real-time demonstrating the label-free biosensing capabilities of the fabricated devices. PMID:24135989

  10. Computational ghost imaging using deep learning

    NASA Astrophysics Data System (ADS)

    Shimobaba, Tomoyoshi; Endo, Yutaka; Nishitsuji, Takashi; Takahashi, Takayuki; Nagahama, Yuki; Hasegawa, Satoki; Sano, Marie; Hirayama, Ryuji; Kakue, Takashi; Shiraki, Atsushi; Ito, Tomoyoshi

    2018-04-01

    Computational ghost imaging (CGI) is a single-pixel imaging technique that exploits the correlation between known random patterns and the measured intensity of light transmitted (or reflected) by an object. Although CGI can obtain two- or three-dimensional images with a single or a few bucket detectors, the quality of the reconstructed images is reduced by noise due to the reconstruction of images from random patterns. In this study, we improve the quality of CGI images using deep learning. A deep neural network is used to automatically learn the features of noise-contaminated CGI images. After training, the network is able to predict low-noise images from new noise-contaminated CGI images.

  11. A simple water-immersion condenser for imaging living brain slices on an inverted microscope.

    PubMed

    Prusky, G T

    1997-09-05

    Due to some physical limitations of conventional condensers, inverted compound microscopes are not optimally suited for imaging living brain slices with transmitted light. Herein is described a simple device that converts an inverted microscope into an effective tool for this application by utilizing an objective as a condenser. The device is mounted on a microscope in place of the condenser, is threaded to accept a water immersion objective, and has a slot for a differential interference contrast (DIC) slider. When combined with infrared video techniques, this device allows an inverted microscope to effectively image living cells within thick brain slices in an open perfusion chamber.

  12. Optimizing the withdrawal speed using dip coating for optical sensor

    NASA Astrophysics Data System (ADS)

    Samat, S. F. A.; Sarah, M. S. P.; Idros, M. Faizol Md; Rusop, M.

    2018-05-01

    The processing route of sol-gel has been used for many productions of thin film using metal oxide such as titanium dioxide, zinc oxide, carbon dioxide and so on. For this research the thin film phase was studied has high transmittance using dip coating technique with different withdrawal speed for optical sensing. The result obtained from optical transmittance spectra that transmits at 30nm and bend at 350nm to 800nm was in the visible light wavelength range. From the data, the withdrawal speed was low at 5s and 10s could give the highest transmittance which were 90.41% and 87.91% respectively.

  13. Light source comprising a common substrate, a first led device and a second led device

    DOEpatents

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  14. Nondestructive and rapid detection of potato black heart based on machine vision technology

    NASA Astrophysics Data System (ADS)

    Tian, Fang; Peng, Yankun; Wei, Wensong

    2016-05-01

    Potatoes are one of the major food crops in the world. Potato black heart is a kind of defect that the surface is intact while the tissues in skin become black. This kind of potato has lost the edibleness, but it's difficult to be detected with conventional methods. A nondestructive detection system based on the machine vision technology was proposed in this study to distinguish the normal and black heart of potatoes according to the different transmittance of them. The detection system was equipped with a monochrome CCD camera, LED light sources for transmitted illumination and a computer. Firstly, the transmission images of normal and black heart potatoes were taken by the detection system. Then the images were processed by algorithm written with VC++. As the transmitted light intensity was influenced by the radial dimension of the potato samples, the relationship between the grayscale value and the potato radial dimension was acquired by analyzing the grayscale value changing rule of the transmission image. Then proper judging condition was confirmed to distinguish the normal and black heart of potatoes after image preprocessing. The results showed that the nondestructive system built coupled with the processing methods was accessible for the detection of potato black heart at a considerable accuracy rate. The transmission detection technique based on machine vision is nondestructive and feasible to realize the detection of potato black heart.

  15. Time-Resolved Rayleigh Scattering Measurements in Hot Gas Flows

    NASA Technical Reports Server (NTRS)

    Mielke, Amy F.; Elam, Kristie A.; Sung, Chih-Jen

    2008-01-01

    A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded gas flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultipler tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. Mean and rms velocity and temperature fluctuation measurements in both an electrically-heated jet facility with a 10-mm diameter nozzle and also in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at NASA Glenn Research Center are presented.

  16. Exploring the effect of diffuse reflection on indoor localization systems based on RSSI-VLC.

    PubMed

    Mohammed, Nazmi A; Elkarim, Mohammed Abd

    2015-08-10

    This work explores and evaluates the effect of diffuse light reflection on the accuracy of indoor localization systems based on visible light communication (VLC) in a high reflectivity environment using a received signal strength indication (RSSI) technique. The effect of the essential receiver (Rx) and transmitter (Tx) parameters on the localization error with different transmitted LED power and wall reflectivity factors is investigated at the worst Rx coordinates for a directed/overall link. Since this work assumes harsh operating conditions (i.e., a multipath model, high reflectivity surfaces, worst Rx position), an error of ≥ 1.46 m is found. To achieve a localization error in the range of 30 cm under these conditions with moderate LED power (i.e., P = 0.45 W), low reflectivity walls (i.e., ρ = 0.1) should be used, which would enable a localization error of approximately 7 mm at the room's center.

  17. Investigation of thermal management technique in blue LED airport taxiway fixtures

    NASA Astrophysics Data System (ADS)

    Gu, Yimin; Baker, Alex; Narendran, Nadarajah

    2007-09-01

    On airport runways, blue light fixtures denote taxiways between the runway and the airport terminal. Blue optics transmit mostly short-wavelength radiation, which makes traditional incandescent lamps a poor choice of light source; the resulting fixture efficiency could be less than one percent. LEDs are replacing incandescent lamps in this application. But unlike incandescent sources, LEDs do not radiate enough heat to melt ice and snow from the fixture optics. To meet Federal Aviation Administration (FAA) regulations for weatherability, some LED-based fixtures incorporate electric heaters that, when switched on, nearly negate the energy-savings benefit of converting to LED sources. In this study, we explored methods for conduction and convection of LED junction heat to taxiway fixture optics for the purpose of minimizing snow and ice buildup. A more efficient LED-based system compared to incandescent that would require no additional heaters was demonstrated.

  18. High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence

    PubMed Central

    Podkowa, Anthony S.; Oelze, Michael L.; Ketterling, Jeffrey A.

    2018-01-01

    The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of ±300 mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow. PMID:29910966

  19. Investigation of Correlation Effects in Nonlinear Optics

    NASA Astrophysics Data System (ADS)

    Friberg, Stephen Richard

    This thesis deals with intensity correlation measurement methods as they apply to the study of light generated by a parametric downconversion process. The correlation properties of light can be used to distinguish between quantum mechanical light and classical light, where quantum mechanical light is electromagnetic radiation that can be accurately described only by a theory that quantizes the field. Spontaneous parametric downconversion produces quantum mechanical light, and we investigate some of its properties. A unique aspect of downconverted light is that pairs of photons are emitted in an interval that can be made smaller than the resolving time of any photon counting apparatus. Our experiments indicate that the interval is not affected by the bandwidth of the pump laser, nor by the length of the crystal. It is apparently determined only by the bandwidth of the detection apparatus, which in our experiment implies that the photons are produced in less than 1 psec, which is much shorter than the 100 psec resolution of our detection apparatus. The normalized cross-correlation functions for spontaneous downconversion are inversely dependent on intensity, but the normalized auto-correlations are independent of intensity. Measurements of the magnitude of the cross -correlations for several different pump beam intensities confirm this relationship. One of the inequalities imposed by classical theory relates the magnitude of the auto-correlations to the magnitude of the cross-correlations. Because of the inverse intensity dependence, this inequality is violated, thereby showing the quantum mechanical nature of the downconverted light. As an application of the large cross-correlations in downconversion, we apply the process to an optical communication channel which transmits information via coincidences between two light beams. Because of the strong discrimination against background provided by this technique, the channel can operate with large amounts of background light. A demonstration experiment of this communication channel is described. A signal transmitted by intensity modulation of the downconverted light is received perfectly by a coincidence counter, but is invisible to a photon counter. Also, a new correlator has been designed and constructed to measure intensity correlation functions. It has been used to measure the correlation properties of a standing -wave, single-mode, inhomogeneously-broadened He:Ne laser as a function of detuning. Results show that detuning of the laser alters the correlation properties in a way that can not be accounted for by merely a change in the pump parameter. These effects should therefore be taken into account when measurements of the statistical properties of the light are made whenever the laser intensity is controlled by detuning.

  20. Understanding the sensitivity of cavity-enhanced absorption spectroscopy: pathlength enhancement versus noise suppression

    NASA Astrophysics Data System (ADS)

    Ouyang, B.; Jones, R. L.

    2012-12-01

    Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 - R) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 - R) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 - R)], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present. The enhancement in A = Δ I/ I, where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I, but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this "numerator" term is not improved, the "denominator" term, I, is reduced considerably; therefore, the increase in contrast ratio Δ I/ I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I, as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I. No suppression is achievable for noise sources that are independent of I, a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this "noise suppression" argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are "suppressed" by the cavity.

  1. Systems and methods for optically measuring properties of hydrocarbon fuel gases

    DOEpatents

    Adler-Golden, S.; Bernstein, L.S.; Bien, F.; Gersh, M.E.; Goldstein, N.

    1998-10-13

    A system and method for optical interrogation and measurement of a hydrocarbon fuel gas includes a light source generating light at near-visible wavelengths. A cell containing the gas is optically coupled to the light source which is in turn partially transmitted by the sample. A spectrometer disperses the transmitted light and captures an image thereof. The image is captured by a low-cost silicon-based two-dimensional CCD array. The captured spectral image is processed by electronics for determining energy or BTU content and composition of the gas. The innovative optical approach provides a relatively inexpensive, durable, maintenance-free sensor and method which is reliable in the field and relatively simple to calibrate. In view of the above, accurate monitoring is possible at a plurality of locations along the distribution chain leading to more efficient distribution. 14 figs.

  2. Systems and methods for optically measuring properties of hydrocarbon fuel gases

    DOEpatents

    Adler-Golden, Steven; Bernstein, Lawrence S.; Bien, Fritz; Gersh, Michael E.; Goldstein, Neil

    1998-10-13

    A system and method for optical interrogation and measurement of a hydrocarbon fuel gas includes a light source generating light at near-visible wavelengths. A cell containing the gas is optically coupled to the light source which is in turn partially transmitted by the sample. A spectrometer disperses the transmitted light and captures an image thereof. The image is captured by a low-cost silicon-based two-dimensional CCD array. The captured spectral image is processed by electronics for determining energy or BTU content and composition of the gas. The innovative optical approach provides a relatively inexpensive, durable, maintenance-free sensor and method which is reliable in the field and relatively simple to calibrate. In view of the above, accurate monitoring is possible at a plurality of locations along the distribution chain leading to more efficient distribution.

  3. Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs

    DOEpatents

    Ury, M.; Sowers, F.; Harper, C.; Love, W.

    1998-11-24

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

  4. Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs

    DOEpatents

    Ury, Michael; Sowers, Frank; Harper, Curt; Love, Wayne

    1998-01-01

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

  5. The application of image processing in the measurement for three-light-axis parallelity of laser ranger

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Qianqian

    2008-12-01

    When laser ranger is transported or used in field operations, the transmitting axis, receiving axis and aiming axis may be not parallel. The nonparallelism of the three-light-axis will affect the range-measuring ability or make laser ranger not be operated exactly. So testing and adjusting the three-light-axis parallelity in the production and maintenance of laser ranger is important to ensure using laser ranger reliably. The paper proposes a new measurement method using digital image processing based on the comparison of some common measurement methods for the three-light-axis parallelity. It uses large aperture off-axis paraboloid reflector to get the images of laser spot and white light cross line, and then process the images on LabVIEW platform. The center of white light cross line can be achieved by the matching arithmetic in LABVIEW DLL. And the center of laser spot can be achieved by gradation transformation, binarization and area filter in turn. The software system can set CCD, detect the off-axis paraboloid reflector, measure the parallelity of transmitting axis and aiming axis and control the attenuation device. The hardware system selects SAA7111A, a programmable vedio decoding chip, to perform A/D conversion. FIFO (first-in first-out) is selected as buffer.USB bus is used to transmit data to PC. The three-light-axis parallelity can be achieved according to the position bias between them. The device based on this method has been already used. The application proves this method has high precision, speediness and automatization.

  6. A Changing Arctic Sea Ice Cover and the Partitioning of Solar Radiation

    NASA Astrophysics Data System (ADS)

    Perovich, D. K.; Light, B.; Polashenski, C.; Nghiem, S. V.

    2010-12-01

    Certain recent changes in the Arctic sea ice cover are well established. There has been a reduction in sea ice extent, an overall thinning of the ice cover, reduced prevalence of perennial ice with accompanying increases in seasonal ice, and a lengthening of the summer melt season. Here we explore the effects of these changes on the partitioning of solar energy between reflection to the atmosphere, absorption within the ice, and transmission to the ocean. The physical changes in the ice cover result in less light reflected and more light absorbed in the ice and transmitted to the ocean. These changes directly affect the heat and mass balance of the ice as well as the amount of light available for photosynthesis within and beneath the ice cover. The central driver is that seasonal ice covers tend to have lower albedo than perennial ice throughout the melt season, permitting more light to penetrate into the ice and ocean. The enhanced light penetration increases the amount of internal melting of the ice and the heat content of the upper ocean. The physical changes in the ice cover mentioned above have affected both the amount and the timing of the photosynthetically active radiation (PAR) transmitted into the ice and ocean, increasing transmitted PAR, particularly in the spring. A comparison of the partitioning of solar irradiance and PAR for both historical and recent ice conditions will be presented.

  7. Light emitting elastomer compositions and method of use

    DOEpatents

    McElhanon, James R.; Zifer, Thomas; Whinnery, LeRoy L.

    2004-11-23

    There is provided a light emitting device comprising a plurality of triboluminescent particles dispersed throughout an elastomeric body and activated by deforming the body in order to transfer mechanical energy to some portion of the particles. The light emitted by these mechanically excited particles is collected and directed into a light conduit and transmitted to a detector/indicator means.

  8. A beam splitter of natural light guiding system based on dichroic prism for ecological illumination

    NASA Astrophysics Data System (ADS)

    Li, Yu-Chi; Chen, Yi-Yung; Whang, Allen Jong-Woei

    2009-08-01

    In thremmatology, many researches focus on ecological illumination for improving the growing speed of animal or plant. According to the Trichromatic theory, any specific color can be made up of red, green, and blue light. Sunlight has full spectrum so it is the most applicable source. A Natural Light Guiding System includes collecting, transmitting, and lighting parts. In our research, we would like to design a beam splitter in the transmitting part to separate the sunlight into red, green, and blue light for ecological illumination. We use high pass and low pass dichroic coatings in a prism, called dichroic prism, to be the beam splitter to separate the wavelength. For measuring the spectra of the exit beams, we build a space with the Natural Light Guiding System. In the space, the spectra of sunlight outside and inside the space and the exit beams of the beam splitter are measured. Finally, we use prismatic structure to design the beam splitter, and optimize the surface of the element with aspheric surface and Fresnel surface to reduce the beam angle of exit light.

  9. Hue-saturation-density (HSD) model for stain recognition in digital images from transmitted light microscopy.

    PubMed

    van Der Laak, J A; Pahlplatz, M M; Hanselaar, A G; de Wilde, P C

    2000-04-01

    Transmitted light microscopy is used in pathology to examine stained tissues. Digital image analysis is gaining importance as a means to quantify alterations in tissues. A prerequisite for accurate and reproducible quantification is the possibility to recognise stains in a standardised manner, independently of variations in the staining density. The usefulness of three colour models was studied using data from computer simulations and experimental data from an immuno-doublestained tissue section. Direct use of the three intensities obtained by a colour camera results in the red-green-blue (RGB) model. By decoupling the intensity from the RGB data, the hue-saturation-intensity (HSI) model is obtained. However, the major part of the variation in perceived intensities in transmitted light microscopy is caused by variations in staining density. Therefore, the hue-saturation-density (HSD) transform was defined as the RGB to HSI transform, applied to optical density values rather than intensities for the individual RGB channels. In the RGB model, the mixture of chromatic and intensity information hampers standardisation of stain recognition. In the HSI model, mixtures of stains that could be distinguished from other stains in the RGB model could not be separated. The HSD model enabled all possible distinctions in a two-dimensional, standardised data space. In the RGB model, standardised recognition is only possible by using complex and time-consuming algorithms. The HSI model is not suitable for stain recognition in transmitted light microscopy. The newly derived HSD model was found superior to the existing models for this purpose. Copyright 2000 Wiley-Liss, Inc.

  10. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    PubMed

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  11. Development of a high spectral resolution lidar based on confocal Fabry-Perot spectral filters.

    PubMed

    Hoffman, David S; Repasky, Kevin S; Reagan, John A; Carlsten, John L

    2012-09-01

    The high spectral resolution lidar (HSRL) instrument described in this paper utilizes the fundamental and second-harmonic output from an injection seeded Nd:YAG laser as the laser transmitter. The light scattered in the atmosphere is collected using a commercial Schmidt-Cassegrain telescope with the optical receiver train first splitting the fundamental and second-harmonic return signal with the fundament light monitored using an avalanche photodiode. The second-harmonic return signal is mode matched into a tunable confocal Fabry-Perot (CFP) interferometer with a free spectral range of 7.5 GHz and a finesse of 50.7 (312) at 532 nm (1064 nm) placed in the optical receiver for spectrally filtering the molecular and aerosol return signals. The light transmitted through the CFP is used to monitor the aerosol return signal while the light reflected from the CFP is used to monitor the molecular return signal. Data collected with the HSRL are presented and inversion results are compared to a co-located solar radiometer, demonstrating the successful operation of the instrument. The CFP-based filtering technique successfully employed by this HSRL instrument is easily portable to other arbitrary wavelengths, thus allowing for the future development of multiwavelength HSRL instruments.

  12. Fiber-optic voltage measuring system

    NASA Astrophysics Data System (ADS)

    Ye, Miaoyuan; Nie, De-Xin; Li, Yan; Peng, Yu; Lin, Qi-Qing; Wang, Jing-Gang

    1993-09-01

    A new fibre optic voltage measuring system has been developed based on the electrooptic effect of bismuth germanium oxide (Bi4Ge3O12)crystal. It uses the LED as the light source. The light beam emitted from the light source is transmitted to the sensor through the optic fibre and the intensity of the output beam is changed by the applied voltage. This optic signal is transmitted to the PIN detector and converted to an electric signal which is processed by the electronic circuit and 8098 single chip microcomputer the output voltage signal obtained is directly proportional to the applied voltage. This paper describes the principle the configuration and the performance parameters of the system. Test results are evaluated and discussed.

  13. Evaluation of cavity size, kind, and filling technique of composite shrinkage by finite element.

    PubMed

    Jafari, Toloo; Alaghehmad, Homayoon; Moodi, Ehsan

    2018-01-01

    Cavity preparation reduces the rigidity of tooth and its resistance to deformation. The purpose of this study was to evaluate the dimensional changes of the repaired teeth using two types of light cure composite and two methods of incremental and bulk filling by the use of finite element method. In this computerized in vitro experimental study, an intact maxillary premolar was scanned using cone beam computed tomography instrument (SCANORA, Switzerland), then each section of tooth image was transmitted to Ansys software using AUTOCAD. Then, eight sizes of cavity preparations and two methods of restoration (bulk and incremental) using two different types of composite resin materials (Heliomolar, Brilliant) were proposed on software and analysis was completed with Ansys software. Dimensional change increased by widening and deepening of the cavities. It was also increased using Brilliant composite resin and incremental filling technique. Increase in depth and type of filling technique has the greatest role of dimensional change after curing, but the type of composite resin does not have a significant role.

  14. Measuring Differential Delays With Sine-Squared Pulses

    NASA Technical Reports Server (NTRS)

    Hurst, Robert N.

    1994-01-01

    Technique for measuring differential delays among red, green, and blue components of video signal transmitted on different parallel channels exploits sine-squared pulses that are parts of standard test signals transmitted during vertical blanking interval of frame period. Technique does not entail expense of test-signal generator. Also applicable to nonvideo signals including sine-squared pulses.

  15. Possibilities of lasers within NOTES.

    PubMed

    Stepp, Herbert; Sroka, Ronald

    2010-10-01

    Lasers possess unique properties that render them versatile light sources particularly for NOTES. Depending on the laser light sources used, diagnostic as well as therapeutic purposes can be achieved. The diagnostic potential offered by innovative concepts such as new types of ultra-thin endoscopes and optical probes supports the physician with optical information of ultra-high resolution, tissue discrimination and manifold types of fluorescence detection. In addition, the potential 3-D capability promises enhanced recognition of tissue type and pathological status. These diagnostic techniques might enable or at least contribute to accurate and safe procedures within the spatial restrictions inherent with NOTES. The therapeutic potential ranges from induction of phototoxic effects over tissue welding, coagulation and tissue cutting to stone fragmentation. As proven in many therapeutic laser endoscopic treatment concepts, laser surgery is potentially bloodless and transmits the energy without mechanical forces. Specialized NOTES endoscopes will likely incorporate suitable probes for improving diagnostic procedures, laser fibres with advantageous light delivery possibility or innovative laser beam manipulation systems. NOTES training centres may support the propagation of the complex handling and the safety aspects for clinical use to the benefit of the patient.

  16. Design of differential optical absorption spectroscopy long-path telescopes based on fiber optics.

    PubMed

    Merten, André; Tschritter, Jens; Platt, Ulrich

    2011-02-10

    We present a new design principle of telescopes for use in the spectral investigation of the atmosphere and the detection of atmospheric trace gases with the long-path differential optical absorption spectroscopy (DOAS) technique. A combination of emitting and receiving fibers in a single bundle replaces the commonly used coaxial-Newton-type combination of receiving and transmitting telescope. This very simplified setup offers a higher light throughput and simpler adjustment and allows smaller instruments, which are easier to handle and more portable. The higher transmittance was verified by ray-tracing calculations, which result in a theoretical factor threefold improvement in signal intensity compared with the old setup. In practice, due to the easier alignment and higher stability, up to factor of 10 higher signal intensities were found. In addition, the use of a fiber optic light source provides a better spectral characterization of the light source, which results in a lower detection limit for trace gases studied with this instrument. This new design will greatly enhance the usability and the range of applications of active DOAS instruments.

  17. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites.

    PubMed

    Bucuta, Stefan; Ilie, Nicoleta

    2014-11-01

    The aim of this study was to quantify the blue light that passes through different incremental thicknesses of bulk fill in comparison to conventional resin-based composites (RBCs) and to relate it to the induced mechanical properties. Seven bulk fill, five nanohybrid and two flowable RBCs were analysed. Specimens (n = 5) of three incremental thicknesses (2, 4 and 6 mm) were cured from the top for 20 s, while at the bottom, a spectrometer monitored in real time the transmitted irradiance. Micro-mechanical properties (Vickers hardness, HV, and indentation modulus, E) were measured at the top and bottom after 24 h of storage in distilled water at 37 °C. Electron microscope images were taken for assessing the filler distribution and size. Bulk fill RBCs (except SonicFill) were more translucent than conventional RBCs. Low-viscosity bulk fill materials showed the lowest mechanical properties. HV depends highly on the following parameters: material (ηp (2) = 0.952), incremental thickness (0.826), filler volume (0.747), filler weight (0.746) and transmitted irradiance (0.491). The bottom-to-top HV ratio (HVbt) was higher than 80 % in all materials in 2- and 4-mm increments (except for Premise), whereas in 6-mm increments, this is valid only in four bulk fill materials (Venus Bulk Fill, SDR, x-tra fil, Tetric EvoCeram Bulk Fill). The depth of cure is dependent on the RBC's translucency. Low-viscosity bulk fill RBCs have lower mechanical properties than all other types of analysed materials. All bulk fill RBCs (except SonicFill) are more translucent for blue light than conventional RBCs. Although bulk fill RBCs are generally more translucent, the practitioner has to follow the manufacturer's recommendations on curing technique and maximum incremental thickness.

  18. Optical probe with light fluctuation protection

    DOEpatents

    Da Silva, Luiz B.; Chase, Charles L.

    2003-11-11

    An optical probe for tissue identification includes an elongated body. Optical fibers are located within the elongated body for transmitting light to and from the tissue. Light fluctuation protection is associated with the optical fibers. In one embodiment the light fluctuation protection includes a reflective coating on the optical fibers to reduce stray light. In another embodiment the light fluctuation protection includes a filler with very high absorption located within the elongated body between the optical fibers.

  19. Method and apparatus for acquisition and tracking of light sources in a transient event rich environment

    NASA Technical Reports Server (NTRS)

    Bolin, Kenneth (Inventor); Flynn, David (Inventor); Fowski, Walter (Inventor); Miklus, Kenneth (Inventor); Kissh, Frank (Inventor); Abreu, Rene (Inventor)

    1993-01-01

    A method and apparatus for tracking a light source in a transient event rich environment locks on to a light source incident on a field-of-view 1 of a charge-coupled-device (CCD) array 6, validates the permanence of said light source and transmits data relating to the brilliance and location of said light source if said light source is determined to be permanent.

  20. A New Idea for Dissecting Tray

    ERIC Educational Resources Information Center

    Branham, Arthur

    1976-01-01

    A method of preparing a special dissecting tray to be used with transmitted light as well as reflected light is presented. It may also be used with an overhead projector to illustrate some skeletal structures in vertebrates. (Author/EB)

  1. Design of the optical system for FSO access

    NASA Astrophysics Data System (ADS)

    Xu, Xiaojing; Yuan, Xiuhua; Huang, Dexiu

    2002-08-01

    Free space optics (FSO) is attractive for the 'last mile' communication in recent years for many combining advantages of fiber communication and other wireless technologies. FSO can provide high data rate with low power consumption, high immunity to interference, convenient deployment and flexibility. Optical system is an important section in the FSO transceiver terminal. In this paper the design of optical system based on a single Galileo telescope for both transmit and receive is proposed, and a polarization beam splitter is adopted to apart the receiving light from transmitting light. The configuration can avoid interference from the retroreflecting light of the ocular effectively. Some factors that affect the performance of the optical system are analyzed, such as the geometrical spreading loss and the loss increment according to pointing error and telescope maladjustment. Power budget shows that the system can satisfy the need of access for 1km in the light fog, and 2km in the thin fog.

  2. Design of optical transmitting antenna with enhance performance in visible light communication

    NASA Astrophysics Data System (ADS)

    Kuang, Dang; Wang, Jianping; Lu, Huimin

    2016-10-01

    An optical transmitting antenna for visible light communication(VLC) is designed in this work, in which the antenna is positioned before the light-emitting diodes (LED) source to change the lighting distribution, in order to achieve uniform received power effect. The method to design antenna is introduced into physical optical lens principle. According to the energy conservation law and Snell law, the antenna is designed via establishing energy mapping between the luminous flux emitted by a LED source with Lambertian distribution and the target plane. The coordinates of the antenna model are obtained under matrix laboratory (MATLAB). The antenna model entity is generated through three dimensional (3D) composition software AutoCAD with the coordinates of antenna. Ray-tracing software Tracepro is used to trace the ray which through antenna, and validate the irradiance maps. The uniformity of illumination and received power of the designed VLC is improved from approximately 35% to over 83%.

  3. Photodynamic decontamination of blood for transfusion

    NASA Astrophysics Data System (ADS)

    Ben-Hur, Ehud; Margolis-Nunno, H.; Gottlieb, P.; Lustigman, S.; Horowitz, Bernard

    1995-01-01

    Currently transfused cellular components of blood are not available in a sterile form and carry a small risk of transmitting viral and parasite diseases. Using phthalocyanines and red light, lipid enveloped viruses, e.g., HIV-1, can be inactivated in red blood cell concentrates (RBCC). Under conditions leading to virus sterilization the blood borne parasites Trypanosoma cruzi (Chagas disease) and Plasmodium falciparum (malaria) could be eliminated to undetectable levels (> 4 log10 kill). RBC damage during treatment could be avoided by increasing the light fluence rate to 80 mW/cm2, and by including the free radical scavenger glutathione and the vitamin E derivative Trolox during light exposure. Similar sterilization of platelet concentrates was achieved with the psoralen derivative AMT and UVA light. Platelet damage due to PUVA treatment was avoided by including the plant flavonoid rutin during irradiation. It is concluded that elimination of the risk of transmitting pathogens during blood transfusion is feasible with photochemical treatments.

  4. One piece microwave container screens for electrodeless lamps

    DOEpatents

    Turner, Brian; Ury, Michael

    1998-01-01

    A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

  5. The light transmission and distribution in an optical fiber coated with TiO2 particles.

    PubMed

    Wang, Wen; Ku, Young

    2003-03-01

    The light delivery and distribution phenomena along the optical fiber coated with the P-25 TiO(2) particles by dipping was investigated. The surface properties (coverage, roughness and thickness) of the TiO(2) layer coated on the optical fiber were characterized by SEM micrographs. For TiO(2) layer prepared from solutions containing less than 20 wt.% of TiO(2) slurry, the thickness of layer was increased linearly with the TiO(2) slurry content in solutions. The UV light intensity transmitted along a TiO(2)-coated optical fiber decreased more rapidly than that transmitted along a non-coated fiber. Based on the experimental results, the light intensity distribution around a coated optical fiber was modeled to determine the optimum configuration for the design of optical fiber reactors under various operational conditions. Copyright 2002 Elsevier Science Ltd.

  6. Transmission intensity disturbance in a rotating polarizer

    NASA Astrophysics Data System (ADS)

    Fan, J. Y.; Li, H. X.; Wu, F. Q.

    2008-01-01

    Random disturbance was observed in transmission intensity in various rotating prism polarizers when they were used in optical systems. As a result, the transmitted intensity exhibited cyclic significant deviation from the Malus cosine-squared law with rotation of prisms. The disturbance spoils the light quality transmitted through the polarizer thus dramatically depresses the accuracies of measurements when the prim polarizers were used in light path. A rigorous model is presented based on the solid basis of multi-beams interference, and theoretical results show good agreement with measured values and also indicate effective method for reducing the disturbance.

  7. Optical Distance Measurement Device And Method Thereof

    DOEpatents

    Bowers, Mark W.

    2004-06-15

    A system and method of efficiently obtaining distance measurements of a target by scanning the target. An optical beam is provided by a light source and modulated by a frequency source. The modulated optical beam is transmitted to an acousto-optical deflector capable of changing the angle of the optical beam in a predetermined manner to produce an output for scanning the target. In operation, reflected or diffused light from the target may be received by a detector and transmitted to a controller configured to calculate the distance to the target as well as the measurement uncertainty in calculating the distance to the target.

  8. DUV phase mask for 100 nm period grating printing

    NASA Astrophysics Data System (ADS)

    Jourlin, Y.; Bourgin, Y.; Reynaud, S.; Parriaux, O.; Talneau, A.; Karvinen, P.; Passilly, N.; Zain, A. Md.; De La Rue, R. M.

    2008-04-01

    Whereas microelectronic lithography is heading to the 32 nm node and discussing immersion and double-patterning strategies, there is much which can be done with the 45 nm node in microoptics for white light processing. For instance, one of the most demanding applications in terms of achievable period is the LCD lossless polarizer, which can transmit the TM polarization and reflect the TE polarization evenly all through the visible spectrum - provided that a 1D metal grid of 100 nm period can be fabricated. The manufacture of such polarizing panels cannot resort to the step & repeat cameras of microelectronics since the substrates are too large, too thin, too wavy and full of contaminants. There is therefore a need for specific fabrication techniques. It is one of these techniques that a subgroup of partners belonging to two of the Networks of Excellence of the European Community, NEMO and ePIXnet, have decided to explore together.

  9. Improved High-Energy Response of AlGaAs/GaAs Solar Cells Using a Low-Cost Technology

    NASA Astrophysics Data System (ADS)

    Noorzad, Camron D.; Zhao, Xin; Harotoonian, Vache; Woodall, Jerry M.

    2016-12-01

    We report on an AlGaAs/GaAs solar cell with a significantly increased high-energy response that was produced via a modified liquid phase epitaxy (LPE) technique. This technique uses a one-step process in which the solid-liquid equilibrium Al-Ga-As:Zn melt in contact with an n-type vendor GaAs substrate simultaneously getters impurities in the substrate that shorten minority carrier lifetimes, diffuses Zn into the substrate to create a p- n junction, and forms a thin p-AlGaAs window layer that enables more high-energy light to be efficiently absorbed. Unlike conventional LPE, this process is performed isothermally. In our "double Al" method, the ratio of Al in the melt ("Al melt ratio") that was used in our process was two times more than what was previously reported in the record 1977 International Business Machines (IBM) solar cell. Photoluminescence (PL) results showed our double Al sample yielded a response to 405 nm light ("blue light"), which was more than twice as intense as the response from our replicated IBM cell. The original 1977 cell had a low-intensity spectral response to photon wavelengths under 443 nm (Woodall and Hovel in Sol Energy Mater Sol Cells 29:176, 1990). Secondary ion mass spectrometry results confirmed the increased blue light response was due to a large reduction in AlGaAs window layer thickness. These results proved increasing the Al melt ratio broadens the spectrum of light that can be transmitted through the window layer into the active GaAs region for absorption, increasing the overall solar cell efficiency. Our enhanced double Al method can pave the way for large-scale manufacturing of low-cost, high-efficiency solar cells.

  10. First Transmitted Hyperspectral Light Measurements and Cloud Properties from Recent Field Campaign Sampling Clouds Under Biomass Burning Aerosol

    NASA Technical Reports Server (NTRS)

    Leblanc, S.; Redemann, Jens; Shinozuka, Yohei; Flynn, Connor J.; Segal Rozenhaimer, Michal; Kacenelenbogen, Meloe Shenandoah; Pistone, Kristina Marie Myers; Schmidt, Sebastian; Cochrane, Sabrina

    2016-01-01

    We present a first view of data collected during a recent field campaign aimed at measuring biomass burning aerosol above clouds from airborne platforms. The NASA ObseRvations of CLouds above Aerosols and their intEractionS (ORACLES) field campaign recently concluded its first deployment sampling clouds and overlying aerosol layer from the airborne platform NASA P3. We present results from the Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR), in conjunction with the Solar Spectral Flux Radiometers (SSFR). During this deployment, 4STAR sampled transmitted solar light either via direct solar beam measurements and scattered light measurements, enabling the measurement of aerosol optical thickness and the retrieval of information on aerosol particles in addition to overlying cloud properties. We focus on the zenith-viewing scattered light measurements, which are used to retrieve cloud optical thickness, effective radius, and thermodynamic phase of clouds under a biomass burning layer. The biomass burning aerosol layer present above the clouds is the cause of potential bias in retrieved cloud optical depth and effective radius from satellites. We contrast the typical reflection based approach used by satellites to the transmission based approach used by 4STAR during ORACLES for retrieving cloud properties. It is suspected that these differing approaches will yield a change in retrieved properties since light transmitted through clouds is sensitive to a different cloud volume than reflected light at cloud top. We offer a preliminary view of the implications of these differences in sampling volumes to the calculation of cloud radiative effects (CRE).

  11. Graphical Approach to Fresnel's Equations for Reflection and Refraction of Light.

    ERIC Educational Resources Information Center

    Doyle, William T.

    1980-01-01

    Develops a coordinate-free approach to Fresnel's equations for the reflection and refraction of light at a plane interface. Describes a graphical construction for finding the vector amplitudes of the reflected and transmitted waves. (Author/CS)

  12. Spin test of turbine rotor

    NASA Technical Reports Server (NTRS)

    Vavra, M. H.; Hammer, J. E.; Bell, L. E.

    1972-01-01

    Experimental data are presented for the tangential and radial stresses in the disks of the 36,000 horsepower, 4000 rpm turbine for the M-1 engine oxidizer turbopump. The two-stage Curtis turbine is a special light-weight design utilizing thin conical disks with hollow sheet metal blades attached by electron-beam welding techniques. The turbine was fabricated from Inconel 718, a nickel-chromium alloy. The stresses were obtained by strain-gage measurements using a slip-ring assembly to transmit the electrical signals. Measurements were made at different rotative speeds and different thermal loads. In addition to presenting test data, the report describes test equipment, design of associated hardware, test procedures, instrumentation, and tests for the selection and calibration of strain gages.

  13. Encryption method based on pseudo random spatial light modulation for single-fibre data transmission

    NASA Astrophysics Data System (ADS)

    Kowalski, Marcin; Zyczkowski, Marek

    2017-11-01

    Optical cryptosystems can provide encryption and sometimes compression simultaneously. They are increasingly attractive for information securing especially for image encryption. Our studies shown that the optical cryptosystems can be used to encrypt optical data transmission. We propose and study a new method for securing fibre data communication. The paper presents a method for optical encryption of data transmitted with a single optical fibre. The encryption process relies on pseudo-random spatial light modulation, combination of two encryption keys and the Compressed Sensing framework. A linear combination of light pulses with pseudo-random patterns provides a required encryption performance. We propose an architecture to transmit the encrypted data through the optical fibre. The paper describes the method, presents the theoretical analysis, design of physical model and results of experiment.

  14. Investigations on magnetic field induced optical transparency in magnetic nanofluids

    NASA Astrophysics Data System (ADS)

    Mohapatra, Dillip Kumar; Philip, John

    2018-02-01

    We study the magnetic field induced optical transparency and its origin in magnetic nanoemulsion of droplets of average size ∼200 nm containing superparamagnetic iron oxide nanoparticles. Beyond a certain volume fraction (Φ > 0.0021) of magnetic nanoemulsion and a critical magnetic field (Hc1), the transmitted light intensity increases drastically and reaches a maximum at another critical magnetic field (Hc2), beyond which the transmitted light intensity decreases and reaches a plateau. Interestingly, the transmitted light intensity at Hc2 is found to increase linearly with Φ and the critical magnetic fields Hc1 and Hc2 follow power law decay with Φ (i.e. Hc ∼ Φ-x), with exponents 0.48 and 0.27, respectively. The light intensity recovers to its initial value when the magnetic field is switched off, indicating the perfect reversibility of the field induced transparency process. The observed straight line scattered patterns above Hc2, on a screen placed perpendicular to the incident beam, confirms the formation of rod like anisotropic nanostructures perpendicular to the direction of light propagation. The magneto-optical measurements in the emulsion confirm that the observed field induced transparency in magnetic emulsions for Φ > 0.0021 is due to the optical birefringence caused by the rod like nanostructures. The reduced birefringence is found to be proportional to the square of the applied magnetic field. This finding offers several possibilities in using magnetic nanofluids in tunable optical devices.

  15. A distributed transmit beamforming synchronization strategy for multi-element radar systems

    NASA Astrophysics Data System (ADS)

    Xiao, Manlin; Li, Xingwen; Xu, Jikang

    2017-02-01

    The distributed transmit beamforming has recently been discussed as an energy-effective technique in wireless communication systems. A common ground of various techniques is that the destination node transmits a beacon signal or feedback to assist source nodes to synchronize signals. However, this approach is not appropriate for a radar system since the destination is a non-cooperative target of an unknown location. In our paper, we propose a novel synchronization strategy for a distributed multiple-element beamfoming radar system. Source nodes estimate parameters of beacon signals transmitted from others to get their local synchronization information. The channel information of the phase propagation delay is transmitted to nodes via the reflected beacon signals as well. Next, each node generates appropriate parameters to form a beamforming signal at the target. Transmit beamforming signals of all nodes will combine coherently at the target compensating for different propagation delay. We analyse the influence of the local oscillation accuracy and the parameter estimation errors on the performance of the proposed synchronization scheme. The results of numerical simulations illustrate that this synchronization scheme is effective to enable the transmit beamforming in a distributed multi-element radar system.

  16. AIM Photonics: Tomorrow’s Technology at the Speed of Light

    DTIC Science & Technology

    2016-09-01

    design automation companies AIM Photonics Tomorrow’s Technology at the Speed of Light Michael Liehr Defense AT&L: September-October 2010 386...in speed and complexity will increase cost, power consumption and heat too much to allow further, practical miniaturization. Light propagates...Integrated microwave photonic circuits (using light to transmit and process optical signals encoded with ana- log information at frequencies in the

  17. Optical Imaging of Flow Pattern and Phantom

    NASA Technical Reports Server (NTRS)

    Galland, Pierre A.; Liang, X.; Wang, L.; Ho, P. P.; Alfano, R. R.; Breisacher, K.

    1999-01-01

    Time-resolved optical imaging technique has been used to image the spatial distribution of small droplets and jet sprays in a highly scattering environment. The snake and ballistic components of the transmitted pulse are less scattered, and contain direct information about the sample to facilitate image formation as opposed to the diffusive components which are due to multiple collisions as a light pulse propagates through a scattering medium. In a time-gated imaging scheme, these early-arriving, image-bearing components of the incident pulse are selected by opening a gate for an ultrashort period of time and a shadowgram image is detected. Using a single shot cooled CCD camera system, the formation of water droplets is monitored as a function of time. Picosecond time-gated image of drop in scattering cells, spray droplets as a function of let speed and gas pressure, and model calcification samples consisted of calcium carbonate particles of irregular shapes ranging in size from 0. 1 to 1.5 mm affixed to a microscope slide have been measured. Formation produced by an impinging jet will be further monitored using a CCD with 1 kHz framing illuminated with pulsed light. The desired image resolution of the fuel droplets is on the 20 pm scale using early light through a highly scattering medium. A 10(exp -6)m displacement from a jet spray with a flow speed of 100 m/sec introduced by the ns grating pulse used in the imaging is negligible. Early ballistic/snake light imaging offers nondestructive and noninvasive method to observe the spatial distribution of hidden objects inside a highly scattering environment for space, biomedical, and materials applications. In this paper, the techniques we will present are time-resolved K-F transillumination imaging and time-gated scattered light imaging. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

  18. Evidence of structurally continuous collagen fibrils in tendons.

    PubMed

    Svensson, Rene B; Herchenhan, Andreas; Starborg, Tobias; Larsen, Michael; Kadler, Karl E; Qvortrup, Klaus; Magnusson, S Peter

    2017-03-01

    Tendons transmit muscle-generated force through an extracellular matrix of aligned collagen fibrils. The force applied by the muscle at one end of a microscopic fibril has to be transmitted through the macroscopic length of the tendon by mechanisms that are poorly understood. A key element in this structure-function relationship is the collagen fibril length. During embryogenesis short fibrils are produced but they grow rapidly with maturation. There is some controversy regarding fibril length in adult tendon, with mechanical data generally supporting discontinuity while structural investigations favor continuity. This study initially set out to trace the full length of individual fibrils in adult human tendons, using serial block face-scanning electron microscopy. But even with this advanced technique the required length could not be covered. Instead a statistical approach was used on a large volume of fibrils in shorter image stacks. Only a single end was observed after tracking 67.5mm of combined fibril lengths, in support of fibril continuity. To shed more light on this observation, the full length of a short tendon (mouse stapedius, 125μm) was investigated and continuity of individual fibrils was confirmed. In light of these results, possible mechanisms that could reconcile the opposing findings on fibril continuity are discussed. Connective tissues hold all parts of the body together and are mostly constructed from thin threads of the protein collagen (called fibrils). Connective tissues provide mechanical strength and one of the most demanding tissues in this regard are tendons, which transmit the forces generated by muscles. The length of the collagen fibrils is essential to the mechanical strength and to the type of damage the tissue may experience (slippage of short fibrils or breakage of longer ones). This in turn is important for understanding the repair processes after such damage occurs. Currently the issue of fibril length is contentious, but this study provides evidence that the fibrils are extremely long and likely continuous. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Electrical tuning of the polarization state of light using graphene-integrated anisotropic metasurfaces

    NASA Astrophysics Data System (ADS)

    Dutta-Gupta, Shourya; Dabidian, Nima; Kholmanov, Iskandar; Belkin, Mikhail A.; Shvets, Gennady

    2017-03-01

    Plasmonic metasurfaces have been employed for moulding the flow of transmitted and reflected light, thereby enabling numerous applications that benefit from their ultra-thin sub-wavelength format. Their appeal is further enhanced by the incorporation of active electro-optic elements, paving the way for dynamic control of light's properties. In this paper, we realize a dynamic polarization state generator using a graphene-integrated anisotropic metasurface (GIAM) that converts the linear polarization of the incident light into an elliptical one. This is accomplished by using an anisotropic metasurface with two principal polarization axes, one of which possesses a Fano-type resonance. A gate-controlled single-layer graphene integrated with the metasurface was employed as an electro-optic element controlling the phase and intensity of light polarized along the resonant axis of the GIAM. When the incident light is polarized at an angle to the resonant axis of the metasurface, the ellipticity of the reflected light can be dynamically controlled by the application of a gate voltage. Thus accomplished dynamic polarization control is experimentally demonstrated and characterized by measuring the Stokes polarization parameters. Large changes of the ellipticity and the tilt angle of the polarization ellipse are observed. Our measurements show that the tilt angle can be changed from positive values through zero to negative values while keeping the ellipticity constant, potentially paving the way to rapid ellipsometry and other characterization techniques requiring fast polarization shifting. This article is part of the themed issue 'New horizons for nanophotonics'.

  20. A simple low-cost microcontroller-based photometric instrument for monitoring chloroplast movement.

    PubMed

    Berg, Robert; Königer, Martina; Schjeide, Brit-Maren; Dikmak, George; Kohler, Susan; Harris, Gary C

    2006-03-01

    A new microcontroller-based photometric instrument for monitoring blue light dependent changes in leaf transmission (chloroplast movement) was developed based on a modification of the double-beam technique developed by Walzcak and Gabrys [(1980) Photosynthetica 14: 65-72]. A blue and red bicolor light emitting diode (LED) provided both a variable intensity blue actinic light and a low intensity red measuring beam. A phototransistor detected the intensity of the transmitted measuring light. An inexpensive microcontroller independently and precisely controlled the light emission of the bicolor LED. A typical measurement event involved turning off the blue actinic light for 100 mus to create a narrow temporal window for turning on and measuring the transmittance of the red light. The microcontroller was programmed using LogoChip Logo (http://www.wellesley.edu/Physics/Rberg/logochip/) to record fluence rate response curves. Laser scanning confocal microscopy was utilized to correlate the changes in leaf transmission with intercellular chloroplast position. In the dark, the chloroplasts in the spongy mesophyll exhibited no evident asymmetries in their distribution, however, in the palisade layer the cell surface in contact with the overlying epidermis was devoid of chloroplasts. The low light dependent decrease in leaf transmittance in dark acclimated leaves was correlated with the movement of chloroplasts within the palisade layer into the regions previously devoid of chloroplasts. Changes in leaf transmittance were evident within one minute following the onset of illumination. Minimal leaf transmittance was correlated with chloroplasts having retreated from cell surfaces perpendicular to the incident light (avoidance reaction) in both spongy and palisade layers.

  1. 76 FR 27956 - Airworthiness Directives; Eurocopter Deutschland Model EC135 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-13

    ... past, the FADEC FAIL caution light illuminated on a few EC135 T1 helicopters. They state that this was... transmitted to the FADEC. This discrepancy led to the display of the FADEC FAIL caution light and ``freezing... to automatically meter fuel, indicated by a FADEC FAIL cockpit caution light, and subsequent loss of...

  2. Triboluminescent indicator system

    DOEpatents

    Goods, Steven H.; Dentinger, Paul M.; Whinnery, Jr., Leroy L.

    2003-06-24

    There is provided a light emitting device comprising a plurality of triboluminescent particles dispersed throughout a low density, frangible body and activated by rapidly crushing the body in order to transfer mechanical energy to some portion of the particles. The light emitted by these mechanically excited particles is collected and directed into a light conduit and transmitted to a detector/indicator means.

  3. [Research on NIR equivalent spectral measurement].

    PubMed

    Wang, Zhi-Hong; Liu, Jie; Sun, Yu-Yang; Teng, Fei; Lin, Jun

    2013-04-01

    When the spectra of the diffuse reflectance of low reflectivity samples or the transmittance of low transmisivity samples are measured by a portable near infrared (NIR) spectrometer, because there is the noise of the spectrometer, the smaller the reflectance or transmittance of the sample, the lower its SNR. Even if treated by denoise methods, the spectra can not meet the requirement of NIR analysis. So the equivalent spectrum measure method was researched. Based on the intensity of the reflected or transmitted signal by the sample under the traditional measure conditions, the light current of the spectrometer was enlarged, and then the signal of the measured sample increased; the reflected or transmitted light of the measure reference was reduced to avoid the signal of the measure reference over range. Moreover the equivalent spectrum of the sample was calculated in order to make it identical with the spectrum measured by traditional method. Thus the NIR spectral SNR was improved. The results of theory analysis and experiments show that if the light signal of the spectrometer was properly increased according to the reflected or transmitted signal of the low reflectivity or transmisivity sample, the equivalent spectrum was the same as the spectrum measured by traditional method and its SNR was improved.

  4. Cellular-based preemption system

    NASA Technical Reports Server (NTRS)

    Bachelder, Aaron D. (Inventor)

    2011-01-01

    A cellular-based preemption system that uses existing cellular infrastructure to transmit preemption related data to allow safe passage of emergency vehicles through one or more intersections. A cellular unit in an emergency vehicle is used to generate position reports that are transmitted to the one or more intersections during an emergency response. Based on this position data, the one or more intersections calculate an estimated time of arrival (ETA) of the emergency vehicle, and transmit preemption commands to traffic signals at the intersections based on the calculated ETA. Additional techniques may be used for refining the position reports, ETA calculations, and the like. Such techniques include, without limitation, statistical preemption, map-matching, dead-reckoning, augmented navigation, and/or preemption optimization techniques, all of which are described in further detail in the above-referenced patent applications.

  5. Polarimetry of nacre in iridescent shells

    NASA Astrophysics Data System (ADS)

    Metzler, R. A.; Burgess, C.; Regan, B.; Spano, S.; Galvez, E. J.

    2014-09-01

    We investigate the light transmitted or reflected from nacre (mother of pearl) taken from the iridescent shell of the bivalve Pinctad a fucata. These nacre surfaces have a rich structure, composed of aragonite crystals arranged as tablets or bricks, 5 μm wide and 400-500 nm thick, surrounded by 30nm thick organic mortar. The light reflected from these shell surfaces, or transmitted through thin polished layers, is rich in its polarization content, exhibiting a space dependent variation in the state of polarization with a high density of polarization singularities. Our goal is to use the polarization information to infer the structure of the biominerals and the role of the organic layer in determining the orientation of the crystals. In the experiments we send the light from a laser with a uniform state of polarization onto the shell, and analyze the light that is either transmitted or reflected, depending on the type of experiment, imaging it after its passage through polarization filters. We use the images from distinct filters to obtain the Stokes parameters, and hence the state of polarization, of each image point. We also construct the Mueller matrix for each imaged point, via 36 measurements. We do this for distinct physical and chemical treatments of the shell sample. Preliminary data shows that the organic layer may be responsible for organizing a multi-crystalline arrangement of aragonite tablets.

  6. Development of bacterial colony phenotyping instrument using reflected scatter light

    NASA Astrophysics Data System (ADS)

    Doh, Iyll-Joon

    Bacterial rapid detection using optical scattering technology (BARDOT) involves in differentiating elastic scattering pattern of bacterial colony. This elastic light scatter technology has shown promising label-free classification rate. However, there is limited success in certain circumstances where either a growth media or a colony has higher opacity. This situation is due to the physical principles of the current BARDOT which mainly relies on optical patterns generated by transmitted signals. Incoming light is obstructed and cannot be transmitted through the dense bacterial colonies, such as Lactobacillus, Yeast, mold and soil bacteria. Moreover, a blood agar, widely used in clinical field, is an example of an opaque media that does not allow light to be transmitted through. Therefore, in this research, a newly designed reflection type scatterometer is presented. The reflection type scatterometer measures the elastic scattering pattern generated by reflected signal. A theoretical model to study the optical pattern characteristic with respect to bacterial colony morphology is presented. Both theoretical and experiment results show good agreement that the size of backward scattering pattern has positive correlation to colony aspect ratio, a colony elevation to diameter ratio. Four pathogenic bacteria on blood agar, Escherichia coli K12, Listeria innocua, Salmonella Typhimurium, and Staphylococcus aureus, are tested and measured with proposed instrument. The measured patterns are analyzed with a classification software, and high classification rate can be achieved.

  7. Thumb-size ultrasonic-assisted spectroscopic imager for in-situ glucose monitoring as optional sensor of conventional dialyzers

    NASA Astrophysics Data System (ADS)

    Nogo, Kosuke; Mori, Keita; Qi, Wei; Hosono, Satsuki; Kawashima, Natsumi; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2016-03-01

    We proposed the ultrasonic-assisted spectroscopic imaging for the realization of blood-glucose-level monitoring during dialytic therapy. Optical scattering and absorption caused by blood cells deteriorate the detection accuracy of glucose dissolved in plasma. Ultrasonic standing waves can agglomerate blood cells at nodes. In contrast, around anti-node regions, the amount of transmitted light increases because relatively clear plasma appears due to decline the number of blood cells. Proposed method can disperse the transmitted light of plasma without time-consuming pretreatment such as centrifugation. To realize the thumb-size glucose sensor which can be easily attached to dialysis tubes, an ultrasonic standing wave generator and a spectroscopic imager are required to be small. Ultrasonic oscillators are ∅30[mm]. A drive circuit of oscillators, which now size is 41×55×45[mm], is expected to become small. The trial apparatus of proposed one-shot Fourier spectroscopic imager, whose size is 30×30×48[mm], also can be little-finger size in principal. In the experiment, we separated the suspension mixed water and micro spheres (Θ10[mm) into particles and liquid regions with the ultrasonic standing wave (frequency: 2[MHz]). Furthermore, the spectrum of transmitted light through the suspension could be obtained in visible light regions with a white LED.

  8. Multi-channel infrared thermometer

    DOEpatents

    Ulrickson, Michael A.

    1986-01-01

    A device for measuring the two-dimensional temperature profile of a surface comprises imaging optics for generating an image of the light radiating from the surface; an infrared detector array having a plurality of detectors; and a light pipe array positioned between the imaging optics and the detector array for sampling, transmitting, and distributing the image over the detector surfaces. The light pipe array includes one light pipe for each detector in the detector array.

  9. [Surveillance on the prevalence of soil-transmitted nematode infection in Fujian in 2006-2010].

    PubMed

    Chen, Bao-jian; Li, Li-sha; Zhang, Rong-yan; Li, Yan-rong; Zhang, Zhi-fang; Zheng, Guo-bin; Fang, Yan-yan; Lin, Chen-xin; Jiang, Dian-wei

    2012-02-29

    To analyze the prevalent trend of soil-transmitted nematode infection in Fujian Province during the past 5 year surveillance and evaluate the control effect. From 2006 to 2010, fecal samples of the inhabitants of 3 years old and above were collected every November and examined for intestinal helminth eggs by the modified Kato s thick smear technique at the 2 surveillance sites: Punan village of Zhangzhou and Gushan village of Shaowu. Cellophane tapes were used to detect pinworm eggs for children aged 3-12. Soil samples were also collected from vegetable field, lavatory, courtyard and kitchen of 20 randomly selected families (in 2 villages) each with stool egg-positive findings and examined for ascaris eggs by a modified saturated sodium nitrate floatation method. The prevalence of soil-transmitted nematode infection at the surveillance sites decreased from 45.3% (946/2087) in 2006 to 15.1% (226/1494) in 2010, with a reduction of 66.6%. Among the infected subjects, hookworm infection occupied 75%-85%, while ascaris or trichuris infections each accounted for less than 10%. In terms of infection intensity, 65.2%-85.5% of the hookworm infection was light, and majority of the infected subjects were farmers. The pinworm prevalence in children were still high although it had dropped down from 46.1% (140/304) in 2006 to 29.8% (36/121) in 2010, declined by 35.4%. In the 5 years, totally 400 soil samples from 100 families were examined and 21 samples were found ascaris egg positive with viable eggs in only one sample. The 5 year surveillance reveals a decreasing trend of the soil-transmitted nematode prevalence but shows a relatively high hookworm infection rate in the population and pinworm infection in children.

  10. Inhomogeneity in optical properties of rat brain: a study for LLLT dosimetry

    NASA Astrophysics Data System (ADS)

    Sousa, Marcelo V. P.; Prates, Renato; Kato, Ilka T.; Sabino, Caetano P.; Yoshimura, Tania M.; Suzuki, Luis C.; Magalhães, Ana C.; Yoshimura, Elisabeth M.; Ribeiro, Martha S.

    2013-03-01

    Over the last few years, low-level light therapy (LLLT) has shown an incredible suitability for a wide range of applications for central nervous system (CNS) related diseases. In this therapeutic modality light dosimetry is extremely critical so the study of light propagation through the CNS organs is of great importance. To better understand how light intensity is delivered to the most relevant neural sites we evaluated optical transmission through slices of rat brain point by point. We experimented red (λ = 660 nm) and near infrared (λ = 808 nm) diode laser light analyzing the light penetration and distribution in the whole brain. A fresh Wistar rat (Rattus novergicus) brain was cut in sagittal slices and illuminated with a broad light beam. A high-resolution digital camera was employed to acquire data of transmitted light. Spatial profiles of the light transmitted through the sample were obtained from the images. Peaks and valleys in the profiles show sites where light was less or more attenuated. The peak intensities provide information about total attenuation and the peak widths are correlated to the scattering coefficient at that individual portion of the sample. The outcomes of this study provide remarkable information for LLLT dose-dependent studies involving CNS and highlight the importance of LLLT dosimetry in CNS organs for large range of applications in animal and human diseases.

  11. Decorative power generating panels creating angle insensitive transmissive colors

    PubMed Central

    Lee, Jae Yong; Lee, Kyu-Tae; Seo, Sungyong; Guo, L. Jay

    2014-01-01

    We present ultra-thin (6 to 31 nm) undoped amorphous silicon/organic hybrid solar cell structure, which can transmit desired color of light. The transmitted colors show great angular tolerance due to the negligible optical phase associated with light propagating in ultra-thin amorphous silicon (a-Si) layers. We achieved the power conversion efficiency of the hybrid cells up to 2 %; and demonstrated that most of the absorbed photons in the undoped a-Si layer contributed to the extracted electric charges due to the suppressed electron-hole recombination in the ultra-thin a-Si layer. We also show the resonance is invariant with respect to the angle of incidence up to ±70° regardless of the polarization of the incident light. Our exploration provides a design to realize energy harvesting colored photovoltaic panels for innovative applications. PMID:24577075

  12. Decorative power generating panels creating angle insensitive transmissive colors

    NASA Astrophysics Data System (ADS)

    Lee, Jae Yong; Lee, Kyu-Tae; Seo, Sungyong; Guo, L. Jay

    2014-02-01

    We present ultra-thin (6 to 31 nm) undoped amorphous silicon/organic hybrid solar cell structure, which can transmit desired color of light. The transmitted colors show great angular tolerance due to the negligible optical phase associated with light propagating in ultra-thin amorphous silicon (a-Si) layers. We achieved the power conversion efficiency of the hybrid cells up to 2 %; and demonstrated that most of the absorbed photons in the undoped a-Si layer contributed to the extracted electric charges due to the suppressed electron-hole recombination in the ultra-thin a-Si layer. We also show the resonance is invariant with respect to the angle of incidence up to +/-70° regardless of the polarization of the incident light. Our exploration provides a design to realize energy harvesting colored photovoltaic panels for innovative applications.

  13. Decorative power generating panels creating angle insensitive transmissive colors.

    PubMed

    Lee, Jae Yong; Lee, Kyu-Tae; Seo, Sungyong; Guo, L Jay

    2014-02-28

    We present ultra-thin (6 to 31 nm) undoped amorphous silicon/organic hybrid solar cell structure, which can transmit desired color of light. The transmitted colors show great angular tolerance due to the negligible optical phase associated with light propagating in ultra-thin amorphous silicon (a-Si) layers. We achieved the power conversion efficiency of the hybrid cells up to 2 %; and demonstrated that most of the absorbed photons in the undoped a-Si layer contributed to the extracted electric charges due to the suppressed electron-hole recombination in the ultra-thin a-Si layer. We also show the resonance is invariant with respect to the angle of incidence up to ± 70° regardless of the polarization of the incident light. Our exploration provides a design to realize energy harvesting colored photovoltaic panels for innovative applications.

  14. A transmitting antenna with hexagon illumination shape for four-color VLC

    NASA Astrophysics Data System (ADS)

    Liu, Kexin; Zhang, Lijun; Hu, Shanshan; Xing, Jichuan; Li, Ping'an

    2018-01-01

    This paper demonstrated a compact white light transmitting antenna based on four-color VLC system, which included an integrating rod and a Fresnel lens system. This paper mainly analyzed the homogenizer: the hexagon integrating rod. After simulation and optimizing, the size of this rod is designed as 60mm (length) x 4.35mm (D). As a result of experiments, this antenna which mixes RGBY-LEDs' beam into white light with high uniformity (67.18%), and illuminate the area of 0.75m x 0.75m at 1.77m transmission distance. The color temperature of the detection surface is 5583K, the chromatic aberration is 0.0021, compared with light source E of standard illumination, less than eye solution (0.005). Also, we verified that this antenna could ensure a stable SNR in mobile communication.

  15. Injector Mixing Efficiency Experiments

    NASA Technical Reports Server (NTRS)

    Moser, Marlow D.

    1998-01-01

    Various optical diagnostic techniques such as laser induce fluorescence, Raman spectroscopy, laser Doppler velocimetry, and laser light scattering have been employed to study the flowfield downstream of a single injector element in a optically accessible rocket chamber at Penn State for a number o years. These techniques have been used with both liquid and gaseous oxygen at pressures up to 1000 psia which is the limit of the facility. The purpose of the test programs at Penn State were to develop the techniques and to study the flow field from various injector designs. To extend these studies to higher pressure and ultimately to multiple injectors require the capabilities of the Marshall Space Flight Center. These studies will extend the data base available for the various injector designs to higher pressure as well as to determine the interaction between multiple injectors. During this effort the Princeton Instruments ICCD camera was set up and checked out. The functionality of the system has been thoroughly checked and the shutter compensation time was found to be not working. The controller was returned to the manufacturer for warranty repair. The sensitivity has been measured and found to be approximately 60 counts per photon at maximum gain which agrees with the test data supplied by the manufacturer. The actual value depends on wavelength. The Princeton Instruments camera was been installed in a explosion proof tube for use with the rocket combustor. A 35 mm camera was also made ready for taking still photos inside the combustor. A fiber optic was used to transmit the laser light from an argon-ion laser to the rocket combustor for the light scattering images. This images were obtained for a LOX-hydrogen swirl coax injector. Several still photos were also obtained with the 35 mm camera for these firings.

  16. [Research on symmetrical optical waveguide based surface plasmon resonance sensing with spectral interrogation].

    PubMed

    Zhang, Yi-long; Liu, Le; Guo, Jun; Zhang, Peng-fei; Guo, Ji-hua; Ma, Hui; He, Yong-hong

    2015-02-01

    Surface plasmon resonance (SPR) sensors with spectral interrogation can adopt fiber to transmit light signals, thus leaving the sensing part separated, which is very convenient for miniaturization, remote-sensing and on-site analysis. Symmetrical optical waveguide (SOW) SPR has the same refractive index of the-two buffer media layers adjacent to the metal film, resulting in longer propagation distance, deeper penetration depth and better performance compared to conventional SPR In the present paper, we developed a symmetrical optical, waveguide (SOW) SPR sensor with wavelength interrogation. In the system, MgF2-Au-MgF2 film was used as SOW module for glucose sensing, and a fiber based light source and detection was used in the spectral interrogation. In the experiment, a refractive index resolution of 2.8 x 10(-7) RIU in fluid protocol was acquired. This technique provides advantages of high resolution and could have potential use in compact design, on-site analysis and remote sensing.

  17. Single-shot quantum nondemolition measurement of a quantum-dot electron spin using cavity exciton-polaritons

    NASA Astrophysics Data System (ADS)

    Puri, Shruti; McMahon, Peter L.; Yamamoto, Yoshihisa

    2014-10-01

    We propose a scheme to perform single-shot quantum nondemolition (QND) readout of the spin of an electron trapped in a semiconductor quantum dot (QD). Our proposal relies on the interaction of the QD electron spin with optically excited, quantum well (QW) microcavity exciton-polaritons. The spin-dependent Coulomb exchange interaction between the QD electron and cavity polaritons causes the phase and intensity response of left circularly polarized light to be different than that of right circularly polarized light, in such a way that the QD electron's spin can be inferred from the response to a linearly polarized probe reflected or transmitted from the cavity. We show that with careful device design it is possible to essentially eliminate spin-flip Raman transitions. Thus a QND measurement of the QD electron spin can be performed within a few tens of nanoseconds with fidelity ˜99.95%. This improves upon current optical QD spin readout techniques across multiple metrics, including speed and scalability.

  18. Preliminary Opto-Mechanical Design for the X2000 Transceiver

    NASA Technical Reports Server (NTRS)

    Hemmati, H.; Page, N. A.

    2000-01-01

    Preliminary optical design and mechanical conceptual design for a 30 cm aperture transceiver are described. A common aperture is used for both transmit and receive. Special attention was given to off-axis and scattered light rejection and isolation of the receive channel from the transmit channel. Requirements, details of the design and preliminary performance analysis of the transceiver are provided.

  19. Transparent thin shield for radio frequency transmit coils.

    PubMed

    Rivera, Debra S; Schulz, Jessica; Siegert, Thomas; Zuber, Verena; Turner, Robert

    2015-02-01

    To identify a shielding material compatible with optical head-motion tracking for prospective motion correction and which minimizes radio frequency (RF) radiation losses at 7 T without sacrificing line-of-sight to an imaging target. We evaluated a polyamide mesh coated with silver. The thickness of the coating was approximated from the composition ratio provided by the material vendor and validated by an estimate derived from electrical conductivity and light transmission measurements. The performance of the shield is compared to a split-copper shield in the context of a four-channel transmit-only loop array. The mesh contains less than a skin-depth of silver coating (300 MHz) and attenuates light by 15 %. Elements of the array vary less in the presence of the mesh shield as compared to the split-copper shield indicating that the array behaves more symmetrically with the mesh shield. No degradation of transmit efficiency was observed for the mesh as compared to the split-copper shield. We present a shield compatible with future integration of camera-based motion-tracking systems. Based on transmit performance and eddy-current evaluations the mesh shield is appropriate for use at 7 T.

  20. Suppression of white light generation (supercontinuum) in biological media: a pilot study using human salivary proteins

    NASA Astrophysics Data System (ADS)

    Santhosh, C.; Dharmadhikari, A. K.; Alti, K.; Dharmadhikari, J. A.; Mathur, D.

    2007-02-01

    Propagation of ultrashort pulses of intense, infrared light through transparent medium gives rise to a visually spectacular phenomenon known as supercontinuum (white light) generation wherein the spectrum of transmitted light is very considerably broader than that of the incident light. We have studied the propagation of ultrafast (<45 fs) pulses of intense infrared light through biological media (water, and water doped with salivary proteins) which reveal that white light generation is severely suppressed in the presence of a major salivary protein, α-amylase.

  1. Optically isolated signal coupler with linear response

    DOEpatents

    Kronberg, James W.

    1994-01-01

    An optocoupler for isolating electrical signals that translates an electrical input signal linearly to an electrical output signal. The optocoupler comprises a light emitter, a light receiver, and a light transmitting medium. The light emitter, preferably a blue, silicon carbide LED, is of the type that provides linear, electro-optical conversion of electrical signals within a narrow wavelength range. Correspondingly, the light receiver, which converts light signals to electrical signals and is preferably a cadmium sulfide photoconductor, is linearly responsive to light signals within substantially the same wavelength range as the blue LED.

  2. Cavity-locked ring down spectroscopy

    DOEpatents

    Zare, Richard N.; Paldus, Barbara A.; Harb, Charles C.; Spence, Thomas

    2000-01-01

    Distinct locking and sampling light beams are used in a cavity ring-down spectroscopy (CRDS) system to perform multiple ring-down measurements while the laser and ring-down cavity are continuously locked. The sampling and locking light beams have different frequencies, to ensure that the sampling and locking light are decoupled within the cavity. Preferably, the ring-down cavity is ring-shaped, the sampling light is s-polarized, and the locking light is p-polarized. Transmitted sampling light is used for ring-down measurements, while reflected locking light is used for locking in a Pound-Drever scheme.

  3. Apparatus using the FARADAY effect to locate the magnetic axis of quadrupole magnets

    NASA Astrophysics Data System (ADS)

    Le Bars, Josette

    1994-07-01

    A development using magneto-optic sensors is underway for the location of the magnetic center of long, small aperture, superconducting quadrupole magnets. The paper will describe the measuring methods and the preliminary results which have been obtained with gradients from 2.5 T/m to 10 T/m. The sensors are made of magneto-optic garnets using the Faraday effect which changes an incident beam of linearly polarized light into a transmitted beam of elliptically polarized light. An optical fiber bundle (phi less than 20 micron) carries the incident light to a polarized film, put above the magneto optic sensor. An analyzer film collects the transmitted light. A second optic fiber bundle carries this light toward a visual (microscope, video camera) or analogic data acquisition system. Furthermore, a level is associated with these crystals to determine the gravity direction. The 'mole' is moving along the axis of a warm bore tube when the magnet is superconducting. The present results are promising for measuring quadrupoles of much higher gradients, up to 100 T/m.

  4. Development of ultra-precision micro-cavity measurement technique in HIT-UOI

    NASA Astrophysics Data System (ADS)

    Cui, Jiwen; Li, Lei; Tan, Jiubin

    2010-08-01

    Micro cavities with high aspect ratio are widely used in different fields including aerospace and defense industries with the development of manufacturing technology. So how to measure the dimension of these cavities has become one of the major research subjects in the field of measurement and instrument. This paper describes some activities of the precision micro cavity measurement technique in Center of Ultra-precision Optoelectronic Instrument (UOI), Harbin Institute of Technology (HIT). The key issue of micro cavity measurement in UOI is called touch-trigger measurement method. The first scheme is double optical fiber coupling, in which light coming from the incident optical fiber is transmitted in the reversal direction via the optical fiber coupling into the effluent optical fiber, the lateral displacement of the touch-trigger sensor is transformed into the deflexion of light coming out from the effluent optical fiber, and the deflexion is transformed into an image signal by the object lens and CCD capturing system. And the second scheme is micro focal-length collimation, in which a fiber stem with a ball mounted on its end is used as a probe and a small segment of it is used as a cylindrical lens to collimate a point light source and image it to a camera, the deflection of the fiber stem can be inferred from the change in image acquired by the camera with ultrahigh displacement sensitivity. Experiments for these activities will be given with a focus on the measurement results and repeatability uncertainty.

  5. Soot Imaging and Measurement

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Soot, sometimes referred to as smoke, is made up primarily of the carbon particles generated by most combustion processes. For example, large quantities of soot can be seen issuing from the exhaust pipes of diesel-powered vehicles. Heated soot also is responsible for the warm orange color of candle flames, though that soot is generally consumed before it can exit the flame. Research has suggested that heavy atmospheric soot concentrations aggravate conditions such as pneumonia and asthma, causing many deaths each year. To understand the formation and oxidation of soot, NASA Lewis Research Center scientists, together with several university investigators, are investigating the properties of soot generated in reduced gravity, where the absence of buoyancy allows more time for the particles to grow. The increased time allows researchers to better study the life cycle of these particles, with the hope that increased understanding will lead to better control strategies. To quantify the amount of soot present in a flame, Lewis scientists developed a unique imaging technique that provides quantitative and qualitative soot data over a large field of view. There is significant improvement over the single-point methods normally used. The technique is shown in the sketch, where light from a laser is expanded with a microscope objective, rendered parallel, and passed through a flame where soot particles reduce the amount of light transmitted to the camera. A filter only allows light at the wavelength of the laser to pass to the camera, preventing any extraneous signals. When images of the laser light with and without the flame are compared, a quantitative map of the soot concentration is produced. In addition to that data, a qualitative image of the soot in the flame is also generated, an example of which is displayed in the photo. This technique has the potential to be adapted to real-time process control in industrial powerplants.

  6. Dynamic light scattering homodyne probe

    NASA Technical Reports Server (NTRS)

    Meyer, William V. (Inventor); Cannell, David S. (Inventor); Smart, Anthony E. (Inventor)

    2002-01-01

    An optical probe for analyzing a sample illuminated by a laser includes an input optical fiber operably connectable to the laser where the input optical fiber has an entrance end and an exit end. The probe also includes a first beam splitter where the first beam splitter is adapted to transmit an alignment portion of a light beam from the input fiber exit end and to reflect a homodyning portion of the light beam from the input fiber. The probe also includes a lens between the input fiber exit end and the first beam splitter and a first and a second output optical fiber, each having an entrance end and an exit end, each exit end being operably connectable to respective optical detectors. The probe also includes a second beam splitter which is adapted to reflect at least a portion of the reflected homodyning portion into the output fiber entrance ends and to transmit light from the laser scattered by the sample into the entrance ends.

  7. Video Guidance Sensors Using Remotely Activated Targets

    NASA Technical Reports Server (NTRS)

    Bryan, Thomas C.; Howard, Richard T.; Book, Michael L.

    2004-01-01

    Four updated video guidance sensor (VGS) systems have been proposed. As described in a previous NASA Tech Briefs article, a VGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. The VGS provides relative position and attitude (6-DOF) information between the VGS and its target. In the original intended application, the two vehicles would be spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In the first two of the four VGS systems as now proposed, the tracked vehicle would include active targets that would light up on command from the tracking vehicle, and a video camera on the tracking vehicle would be synchronized with, and would acquire images of, the active targets. The video camera would also acquire background images during the periods between target illuminations. The images would be digitized and the background images would be subtracted from the illuminated-target images. Then the position and orientation of the tracked vehicle relative to the tracking vehicle would be computed from the known geometric relationships among the positions of the targets in the image, the positions of the targets relative to each other and to the rest of the tracked vehicle, and the position and orientation of the video camera relative to the rest of the tracking vehicle. The major difference between the first two proposed systems and prior active-target VGS systems lies in the techniques for synchronizing the flashing of the active targets with the digitization and processing of image data. In the prior active-target VGS systems, synchronization was effected, variously, by use of either a wire connection or the Global Positioning System (GPS). In three of the proposed VGS systems, the synchronizing signal would be generated on, and transmitted from, the tracking vehicle. In the first proposed VGS system, the tracking vehicle would transmit a pulse of light. Upon reception of the pulse, circuitry on the tracked vehicle would activate the target lights. During the pulse, the target image acquired by the camera would be digitized. When the pulse was turned off, the target lights would be turned off and the background video image would be digitized. The second proposed system would function similarly to the first proposed system, except that the transmitted synchronizing signal would be a radio pulse instead of a light pulse. In this system, the signal receptor would be a rectifying antenna. If the signal contained sufficient power, the output of the rectifying antenna could be used to activate the target lights, making it unnecessary to include a battery or other power supply for the targets on the tracked vehicle.

  8. Imaging Spectrometer Designs Utilizing Immersed Gratings With Accessible Entrance Slit

    DOEpatents

    Chrisp, Michael P.; Lerner, Scott A.

    2006-03-21

    A compact imaging spectrometer comprises an entrance slit, a catadioptric lens with a mirrored surface, a grating, and a detector array. The entrance slit directs light to the mirrored surface of the catadioptric lens; the mirrored surface reflects the light back through the lens to the grating. The grating receives the light from the catadioptric lens and diffracts the light to the lens away from the mirrored surface. The lens transmits the light and focuses it onto the detector array.

  9. Photodynamic diagnosis and related optical techniques for the management of malignant glioma

    NASA Astrophysics Data System (ADS)

    Sroka, R.; Stepp, H.; Beyer, W.; Markwardt, N.; Rühm, A.

    2017-04-01

    Malignant gliomas are a devastating brain tumor disease with very poor prognosis. Stereotactic biopsy sampling is routinely used in larger neurosurgical centers to confirm the diagnosis of a suspected brain tumor. This procedure is associated with risk of blood vessel rupture as well as false-negative results. Recent investigations suggest a potential of light-based techniques to improve both therapy and diagnosis of GBM. Optical guidance can be utilized to improve the biopsy sampling procedure in terms of safety, reliability, and efficacy. Recording of optical signals (transmission, remission, fluorescence) can be potentially integrated into a biopsy needle for providing optical detection of tumor tissue and blood vessel recognition during the biopsy sampling. Optical signals can also be used for monitoring purposes during photodynamic therapy. Here, fluorescence signals recorded before the treatment indicate the presence and accumulation level of photosensitizer, while photobleaching of the photosensitizer fluorescence during the treatment can be used as a measure of the effectiveness of the therapy. Finally, transmitted light can reveal problematic tissue-optical conditions as well as changes of the optical properties of the treated tissue, which may be relevant with regard to treatment prognosis and strategy. Different optical concepts for interstitial PDT monitoring and optical tissue property assessment are presented.

  10. Linearized Flux Evolution (LiFE): A technique for rapidly adapting fluxes from full-physics radiative transfer models

    NASA Astrophysics Data System (ADS)

    Robinson, Tyler D.; Crisp, David

    2018-05-01

    Solar and thermal radiation are critical aspects of planetary climate, with gradients in radiative energy fluxes driving heating and cooling. Climate models require that radiative transfer tools be versatile, computationally efficient, and accurate. Here, we describe a technique that uses an accurate full-physics radiative transfer model to generate a set of atmospheric radiative quantities which can be used to linearly adapt radiative flux profiles to changes in the atmospheric and surface state-the Linearized Flux Evolution (LiFE) approach. These radiative quantities describe how each model layer in a plane-parallel atmosphere reflects and transmits light, as well as how the layer generates diffuse radiation by thermal emission and by scattering light from the direct solar beam. By computing derivatives of these layer radiative properties with respect to dynamic elements of the atmospheric state, we can then efficiently adapt the flux profiles computed by the full-physics model to new atmospheric states. We validate the LiFE approach, and then apply this approach to Mars, Earth, and Venus, demonstrating the information contained in the layer radiative properties and their derivatives, as well as how the LiFE approach can be used to determine the thermal structure of radiative and radiative-convective equilibrium states in one-dimensional atmospheric models.

  11. Evaluation of cavity size, kind, and filling technique of composite shrinkage by finite element

    PubMed Central

    Jafari, Toloo; Alaghehmad, Homayoon; Moodi, Ehsan

    2018-01-01

    Background: Cavity preparation reduces the rigidity of tooth and its resistance to deformation. The purpose of this study was to evaluate the dimensional changes of the repaired teeth using two types of light cure composite and two methods of incremental and bulk filling by the use of finite element method. Materials and Methods: In this computerized in vitro experimental study, an intact maxillary premolar was scanned using cone beam computed tomography instrument (SCANORA, Switzerland), then each section of tooth image was transmitted to Ansys software using AUTOCAD. Then, eight sizes of cavity preparations and two methods of restoration (bulk and incremental) using two different types of composite resin materials (Heliomolar, Brilliant) were proposed on software and analysis was completed with Ansys software. Results: Dimensional change increased by widening and deepening of the cavities. It was also increased using Brilliant composite resin and incremental filling technique. Conclusion: Increase in depth and type of filling technique has the greatest role of dimensional change after curing, but the type of composite resin does not have a significant role. PMID:29497445

  12. Photon Doppler velocimetry measurements of transverse surface velocities

    NASA Astrophysics Data System (ADS)

    Johnson, C. R.; LaJeunesse, J. W.; Sable, P. A.; Dawson, A.; Hatzenbihler, A.; Borg, J. P.

    2018-06-01

    The goal of this work was to develop a technique for making transverse surface velocity measures utilizing Photon Doppler Velocimetry (PDV). Such a task is achieved by transmitting light and collecting Doppler-shifted light at an angle relative to the normal axis, where measured velocities are representative of a component of the transverse velocity. Because surface characteristics have an intrinsic effect on light scatter, different surface preparations were explored to direct reflectivity, including diffusion by means of sandpapering, or increasing retroreflectivity by coating with microspheres, milling v-cuts, and electrochemically etching grooves. Testing of these surface preparations was performed using an experiment featuring a 30 mm diameter aluminum disk rotating at 6000 or 6600 RPM. A single PDV collimator was positioned along the rotational axis of the disk at various angles, resolving the apparent transverse velocity. To characterize surface preparations, light return and velocities were recorded as a function of probe angle ranging from 0° to 51° from the surface normal for each preparation. Polished and electrochemically etched surfaces did not provide enough reflected light to resolve a beat frequency; however, sandpapered surfaces, retroreflective microspheres, and milled v-cuts provided adequate reflected light for incidence angles up to 51°. Applications of the surface preparations were then studied in gas gun experiments. Retroreflective microspheres were studied in a planar impact experiment, and milled v-cuts were studied in an oblique impact experiment. A normal and transverse profile of particle velocity was resolved in the oblique impact experiment.

  13. Bandwidth efficient coding: Theoretical limits and real achievements. Error control techniques for satellite and space communications

    NASA Technical Reports Server (NTRS)

    Costello, Daniel J., Jr.; Courturier, Servanne; Levy, Yannick; Mills, Diane G.; Perez, Lance C.; Wang, Fu-Quan

    1993-01-01

    In his seminal 1948 paper 'The Mathematical Theory of Communication,' Claude E. Shannon derived the 'channel coding theorem' which has an explicit upper bound, called the channel capacity, on the rate at which 'information' could be transmitted reliably on a given communication channel. Shannon's result was an existence theorem and did not give specific codes to achieve the bound. Some skeptics have claimed that the dramatic performance improvements predicted by Shannon are not achievable in practice. The advances made in the area of coded modulation in the past decade have made communications engineers optimistic about the possibility of achieving or at least coming close to channel capacity. Here we consider the possibility in the light of current research results.

  14. 77 FR 54848 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-06

    ... damage to the operation of other critical airplane systems due to electromagnetic coupling and large... strike to the tail strobe light, electromagnetic coupling and large transient voltages can be transmitted... electromagnetic coupling, since the tail strobe light is located in a flammable leakage zone, electrical current...

  15. Piezoelectric Bone Surgery: A Review of the Literature and Potential Applications in Veterinary Oromaxillofacial Surgery

    PubMed Central

    Hennet, Philippe

    2015-01-01

    Piezoelectric bone surgery is a recent and innovative technology, permitting a selective cut of mineralized tissue while sparing soft tissue. Similar to a dental scaler, a high frequency vibration, in the range of 25–35 kHz, is transmitted to a metallic tip. However, the power of the piezosurgical instrument is three to six times higher than that of a dental scaler. The major advantages of this technology include high precision, a design that increases ease of curvilinear osteotomy, less trauma to soft tissue, preservation of neurological and vascular structures, reduced hemorrhage, minimal thermal damage to the bone, as well as overall improvement of healing. The handpiece of the instrument is equipped with a sterile irrigation system and light-emitting diode (LED) light, which improves visibility and overall safety. Piezoelectric surgery is particularly useful when performing delicate bone procedures such as periodontal or endodontic surgery. It is also indicated when performing more invasive bone surgery such as maxillectomy, mandibulectomy, and condylectomy, where preservation of neurovascular structures is important. Piezoelectric instruments are different from rotary instrumentation or oscillating saws, they require light pressure with constant motion of the tip. Training is required to master the technique. PMID:26664937

  16. Study on the measuring distance for blood glucose infrared spectral measuring by Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Li, Xiang

    2016-10-01

    Blood glucose monitoring is of great importance for controlling diabetes procedure and preventing the complications. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. Among various parameters of optical fiber probe used in spectrum measuring, the measurement distance is the key one. The Monte Carlo technique is a flexible method for simulating light propagation in tissue. The simulation is based on the random walks that photons make as they travel through tissue, which are chosen by statistically sampling the probability distributions for step size and angular deflection per scattering event. The traditional method for determine the optimal distance between transmitting fiber and detector is using Monte Carlo simulation to find out the point where most photons come out. But there is a problem. In the epidermal layer there is no artery, vein or capillary vessel. Thus, when photons propagate and interactive with tissue in epidermal layer, no information is given to the photons. A new criterion is proposed to determine the optimal distance, which is named effective path length in this paper. The path length of each photons travelling in dermis is recorded when running Monte-Carlo simulation, which is the effective path length defined above. The sum of effective path length of every photon at each point is calculated. The detector should be place on the point which has most effective path length. Then the optimal measuring distance between transmitting fiber and detector is determined.

  17. Optimal control design of turbo spin‐echo sequences with applications to parallel‐transmit systems

    PubMed Central

    Hoogduin, Hans; Hajnal, Joseph V.; van den Berg, Cornelis A. T.; Luijten, Peter R.; Malik, Shaihan J.

    2016-01-01

    Purpose The design of turbo spin‐echo sequences is modeled as a dynamic optimization problem which includes the case of inhomogeneous transmit radiofrequency fields. This problem is efficiently solved by optimal control techniques making it possible to design patient‐specific sequences online. Theory and Methods The extended phase graph formalism is employed to model the signal evolution. The design problem is cast as an optimal control problem and an efficient numerical procedure for its solution is given. The numerical and experimental tests address standard multiecho sequences and pTx configurations. Results Standard, analytically derived flip angle trains are recovered by the numerical optimal control approach. New sequences are designed where constraints on radiofrequency total and peak power are included. In the case of parallel transmit application, the method is able to calculate the optimal echo train for two‐dimensional and three‐dimensional turbo spin echo sequences in the order of 10 s with a single central processing unit (CPU) implementation. The image contrast is maintained through the whole field of view despite inhomogeneities of the radiofrequency fields. Conclusion The optimal control design sheds new light on the sequence design process and makes it possible to design sequences in an online, patient‐specific fashion. Magn Reson Med 77:361–373, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine PMID:26800383

  18. Non-Gaussian Correlations between Reflected and Transmitted Intensity Patterns Emerging from Opaque Disordered Media

    NASA Astrophysics Data System (ADS)

    Starshynov, I.; Paniagua-Diaz, A. M.; Fayard, N.; Goetschy, A.; Pierrat, R.; Carminati, R.; Bertolotti, J.

    2018-04-01

    The propagation of monochromatic light through a scattering medium produces speckle patterns in reflection and transmission, and the apparent randomness of these patterns prevents direct imaging through thick turbid media. Yet, since elastic multiple scattering is fundamentally a linear and deterministic process, information is not lost but distributed among many degrees of freedom that can be resolved and manipulated. Here, we demonstrate experimentally that the reflected and transmitted speckle patterns are robustly correlated, and we unravel all the complex and unexpected features of this fundamentally non-Gaussian and long-range correlation. In particular, we show that it is preserved even for opaque media with thickness much larger than the scattering mean free path, proving that information survives the multiple scattering process and can be recovered. The existence of correlations between the two sides of a scattering medium opens up new possibilities for the control of transmitted light without any feedback from the target side, but using only information gathered from the reflected speckle.

  19. Fast mapping algorithm of lighting spectrum and GPS coordinates for a large area

    NASA Astrophysics Data System (ADS)

    Lin, Chih-Wei; Hsu, Ke-Fang; Hwang, Jung-Min

    2016-09-01

    In this study, we propose a fast rebuild technology for evaluating light quality in large areas. Outdoor light quality, which is measured by illuminance uniformity and the color rendering index, is difficult to conform after improvement. We develop an algorithm for a lighting quality mapping system and coordinates using a micro spectrometer and GPS tracker integrated with a quadcopter or unmanned aerial vehicle. After cruising at a constant altitude, lighting quality data is transmitted and immediately mapped to evaluate the light quality in a large area.

  20. Very high numerical aperture light transmitting device

    DOEpatents

    Allison, Stephen W.; Boatner, Lynn A.; Sales, Brian C.

    1998-01-01

    A new light-transmitting device using a SCIN glass core and a novel calcium sodium cladding has been developed. The very high index of refraction, radiation hardness, similar solubility for rare earths and similar melt and viscosity characteristics of core and cladding materials makes them attractive for several applications such as high-numerical-aperture optical fibers and specialty lenses. Optical fibers up to 60 m in length have been drawn, and several simple lenses have been designed, ground, and polished. Preliminary results on the ability to directly cast optical components of lead-indium phosphate glass are also discussed as well as the suitability of these glasses as a host medium for rare-earth ion lasers and amplifiers.

  1. Inherent secure communications using lattice based waveform design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pugh, Matthew Owen

    2013-12-01

    The wireless communications channel is innately insecure due to the broadcast nature of the electromagnetic medium. Many techniques have been developed and implemented in order to combat insecurities and ensure the privacy of transmitted messages. Traditional methods include encrypting the data via cryptographic methods, hiding the data in the noise floor as in wideband communications, or nulling the signal in the spatial direction of the adversary using array processing techniques. This work analyzes the design of signaling constellations, i.e. modulation formats, to combat eavesdroppers from correctly decoding transmitted messages. It has been shown that in certain channel models the abilitymore » of an adversary to decode the transmitted messages can be degraded by a clever signaling constellation based on lattice theory. This work attempts to optimize certain lattice parameters in order to maximize the security of the data transmission. These techniques are of interest because they are orthogonal to, and can be used in conjunction with, traditional security techniques to create a more secure communication channel.« less

  2. Noise-Immune Cavity-Enhanced Optical Frequency Comb Spectroscopy

    NASA Astrophysics Data System (ADS)

    Rutkowski, Lucile; Khodabakhsh, Amir; Johanssson, Alexandra C.; Foltynowicz, Aleksandra

    2015-06-01

    We present noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS), a recently developed technique for sensitive, broadband, and high resolution spectroscopy. In NICE-OFCS an optical frequency comb (OFC) is locked to a high finesse cavity and phase-modulated at a frequency precisely equal to (a multiple of) the cavity free spectral range. Since each comb line and sideband is transmitted through a separate cavity mode in exactly the same way, any residual frequency noise on the OFC relative to the cavity affects each component in an identical manner. The transmitted intensity contains a beat signal at the modulation frequency that is immune to frequency-to-amplitude noise conversion by the cavity, in a way similar to continuous wave noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS). The light transmitted through the cavity is detected with a fast-scanning Fourier-transform spectrometer (FTS) and the NICE-OFCS signal is obtained by fast Fourier transform of the synchronously demodulated interferogram. Our NICE-OFCS system is based on an Er:fiber femtosecond laser locked to a cavity with a finesse of ˜9000 and a fast-scanning FTS equipped with a high-bandwidth commercial detector. We measured NICE-OFCS signals from the 3νb{1}+νb{3} overtone band of CO_2 around 1.57 μm and achieved absorption sensitivity 6.4×10-11cm-1 Hz-1/2 per spectral element, corresponding to a minimum detectable CO_2 concentration of 25 ppb after 330 s integration time. We will describe the principles of the technique and its technical implementation, and discuss the spectral lineshapes of the NICE-OFCS signals. A. Khodabakhsh, C. Abd Alrahman, and A. Foltynowicz, Opt. Lett. 39, 5034-5037 (2014). J. Ye, L. S. Ma, and J. L. Hall, J. Opt. Soc. Am. B 15, 6-15 (1998). A. Khodabakhsh, A. C. Johansson, and A. Foltynowicz, Appl. Phys. B (2015) doi:10.1007/s00340-015-6010-7.

  3. Position indicator

    DOEpatents

    Tanner, David E.

    1981-01-01

    A nuclear reactor system is described in which a position indicator is provided for detecting and indicating the position of a movable element inside a pressure vessel. The movable element may be a valve element or similar device which moves about an axis. Light from a light source is transmitted from a source outside the pressure vessel to a first region inside the pressure vessel in alignment with the axis of the movable element. The light is redirected by a reflector prism to a second region displaced radially from the first region. The reflector prism moves in response to movement of the movable element about its axis such that the second region moves arcuately with respect to the first region. Sensors are arrayed in an arc corresponding to the arc of movement of the second region and signals are transmitted from the sensors to the exterior of the reactor vessel to provide indication of the position of the movable element.

  4. Detection of chlorinated aromatic compounds

    DOEpatents

    Ekechukwu, A.A.

    1996-02-06

    A method for making a composition for measuring the concentration of chlorinated aromatic compounds in aqueous fluids, and an optical probe for use with the method are disclosed. The composition comprises a hydrophobic polymer matrix, preferably polyamide, with a fluorescent indicator uniformly dispersed therein. The indicator fluoresces in the presence of the chlorinated aromatic compounds with an intensity dependent on the concentration of these compounds in the fluid of interest, such as 8-amino-2-naphthalene sulfonate. The probe includes a hollow cylindrical housing that contains the composition in its distal end. The probe admits an aqueous fluid to the probe interior for exposure to the composition. An optical fiber transmits excitation light from a remote source to the composition while the indicator reacts with chlorinated aromatic compounds present in the fluid. The resulting fluorescence light signal is reflected to a second optical fiber that transmits the light to a spectrophotometer for analysis. 5 figs.

  5. Rayleigh Scattering Diagnostic for Measurement of Temperature and Velocity in Harsh Environments

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard G.; Greer, Lawrence C., III

    1998-01-01

    A molecular Rayleigh scattering system for temperature and velocity measurements in unseeded flows is described. The system is capable of making measurements in the harsh environments commonly found in aerospace test facilities, which may have high acoustic sound levels, varying temperatures, and high vibration levels. Light from an argon-ion laser is transmitted via an optical fiber to a remote location where two flow experiments were located. One was a subsonic free air jet; the second was a low-speed heated airjet. Rayleigh scattered light from the probe volume was transmitted through another optical fiber from the remote location to a controlled environment where a Fabry-Perot interferometer and cooled CCD camera were used to analyze the Rayleigh scattered light. Good agreement between the measured velocity and the velocity calculated from isentropic flow relations was demonstrated (less than 5 m/sec). The temperature measurements, however, exhibited systematic errors on the order of 10-15%.

  6. Detection of chlorinated aromatic compounds

    DOEpatents

    Ekechukwu, Amy A.

    1996-01-01

    A method for making a composition for measuring the concentration of chloated aromatic compounds in aqueous fluids, and an optical probe for use with the method. The composition comprises a hydrophobic polymer matrix, preferably polyamide, with a fluorescent indicator uniformly dispersed therein. The indicator fluoresces in the presence of the chlorinated aromatic compounds with an intensity dependent on the concentration of these compounds in the fluid of interest, such as 8-amino-2-naphthalene sulfonate. The probe includes a hollow cylindrical housing that contains the composition in its distal end. The probe admits an aqueous fluid to the probe interior for exposure to the composition. An optical fiber transmits excitation light from a remote source to the composition while the indicator reacts with chlorinated aromatic compounds present in the fluid. The resulting fluorescence light signal is reflected to a second optical fiber that transmits the light to a spectrophotometer for analysis.

  7. Understanding transparency perception in architecture: presentation of the simplified perforated model.

    PubMed

    Brzezicki, Marcin

    2013-01-01

    Issues of transparency perception are addressed from an architectural perspective, pointing out previously neglected factors that greatly influence this phenomenon in the scale of a building. The simplified perforated model of a transparent surface presented in the paper has been based on previously developed theories and involves the balance of light reflected versus light transmitted. Its aim is to facilitate an understanding of non-intuitive phenomena related to transparency (eg dynamically changing reflectance) for readers without advanced knowledge of molecular physics. A verification of the presented model has been based on the comparison of optical performance of the model with the results of Fresnel's equations for light-transmitting materials. The presented methodology is intended to be used both in the design and explanatory stages of architectural practice and vision research. Incorporation of architectural issues could enrich the perspective of scientists representing other disciplines.

  8. Electro-optic study of PZT ferroelectric ceramics using modulation of reflected light

    NASA Astrophysics Data System (ADS)

    Kniazkov, A. V.

    2016-04-01

    Electro-optic coefficients of variations in the refractive index of PZT and PLZT ceramic materials induced by ac electric field are estimated using modulation of reflected light. The electro-optic coefficients of PLZT ceramics measured with the aid of conventional birefringence using the phase shift of transmitted radiation and the proposed method of birefringence using the modulation of reflected light are compared.

  9. Secure and Robust Transmission and Verification of Unknown Quantum States in Minkowski Space

    PubMed Central

    Kent, Adrian; Massar, Serge; Silman, Jonathan

    2014-01-01

    An important class of cryptographic applications of relativistic quantum information work as follows. B generates a random qudit and supplies it to A at point P. A is supposed to transmit it at near light speed c to to one of a number of possible pairwise spacelike separated points Q1, …, Qn. A's transmission is supposed to be secure, in the sense that B cannot tell in advance which Qj will be chosen. This poses significant practical challenges, since secure reliable long-range transmission of quantum data at speeds near to c is presently not easy. Here we propose different techniques to overcome these diffculties. We introduce protocols that allow secure long-range implementations even when both parties control only widely separated laboratories of small size. In particular we introduce a protocol in which A needs send the qudit only over a short distance, and securely transmits classical information (for instance using a one time pad) over the remaining distance. We further show that by using parallel implementations of the protocols security can be maintained in the presence of moderate amounts of losses and errors. PMID:24469425

  10. Intestinal helminth infections among inmates in Bedele prison with emphasis on soil-transmitted helminths.

    PubMed

    Terefe, Bahiru; Zemene, Endalew; Mohammed, Abdurehman E

    2015-12-14

    Intestinal helminths infect more than two billion people worldwide. They are common in developing countries where sanitary facilities are inadequate. There is scarcity of documented data on the magnitude of intestinal helminths among inmates in Ethiopia. The aim of this study was to determine prevalence of intestinal helminth infections among inmates in Bedele prison, south-western Ethiopia. A cross-sectional study involving 234 inmates in Bedele prison was conducted in April 2012. Socio-demographic data was collected from each study participant using semi-structured questionnaire. Fresh stool specimens were collected and processed using modified McMaster technique. At least one species of intestinal helminth was identified in 111 (47.4 %) of the inmates. Ascaris lumbricoides was the most predominant parasite isolated, followed by the hookworms. Most of the cases of soil-transmitted helminths (STHs) were light infections. Untrimmed hand fingernails was significantly associated with A. lumbricoides infection (AOR 0.383, 95 % CI 0.200-0.731). Intestinal helminths are common among the inmates in Bedele prison. Health information should be given to the inmates on proper personal hygiene practices with emphasis on trimming of hand fingernails. Monitoring helminth infections in the inmate population is required.

  11. The Magic Ear: Another Approach to Automated Classroom Control.

    ERIC Educational Resources Information Center

    George, James R., III; And Others

    "Excessive" noise outburst behavior of 24 second graders was effectively controlled under automated stimulus conditions. A voice operated relay transmitted signals to an automated combination light display and outburst time/total running time meters; under 2 conditions, the light display functioned first as a primary, then as a secondary…

  12. On the performance of a code division multiple access scheme with transmit/receive conflicts

    NASA Astrophysics Data System (ADS)

    Silvester, J. A.

    One of the benefits of spread spectrum is that by assigning each user a different orthogonal signal set, multiple transmissions can occur simultaneously. This possibility is utilized in new access schemes called Code Division Multiple Access (CDMA). The present investigation is concerned with a particular CDMA implementation in which the transmit times for each symbol are exactly determined in a distributed manner such that both sender and receiver know them. In connection with a decision whether to transmit or receive, the loss of a symbol in one of the channels results. The system employs thus a coding technique which permits correct decoding of a codeword even if some constituent symbols are missing or in error. The technique used is Reed Solomon coding. The performance of this system is analyzed, and attention is given to the optimum strategy which should be used in deciding whether to receive or transmit.

  13. Soil transmitted helminths and associated factors among schoolchildren in government and private primary school in Jimma Town, Southwest Ethiopia.

    PubMed

    Debalke, Serkadis; Worku, Amare; Jahur, Nejat; Mekonnen, Zeleke

    2013-11-01

    Soil transmitted helminth infections are among the most common human infections. They are distributed throughout the world with high prevalence rates in tropical and sub-tropical countries mainly because of lack of adequate sanitary facilities, inappropriate waste disposal systems, lack of safe water supply, and low socio-economic status. A comparative cross sectional study was conducted from December 2011 to June 2012 to determine and assess the prevalence of soil transmitted helminths and their associated factors among government and private primary school children. Stool samples were collected from 369 randomly selected children and examined microscopically for eggs of soil transmitted helminth following McMaster techniques. Soil samples were collected from different parts of the school compound and microscopic examination was performed for eggs of the helminths using sodium nitrate flotation technique. The overall prevalence rate of soil transmitted helminth infections in private and government schools was 20.9% and 53.5% respectively. T. trichiura was the most common soil transmitted helminth in both schools while hookworm infections were identified in government school students only. Type of school and sex were significantly associated with soil transmitted helminth. Soil contamination rate of the school compounds was 11.25% with predominant parasites of A. lumbricoides. Higher prevalence of soil transmitted helminth infection was found among government school students. Thus, more focus, on personal hygiene and sanitary facilities, should be given to children going to government schools.

  14. Rapid approach to the quantitative determination of nocturnal ground irradiance in populated territories: a clear-sky case

    NASA Astrophysics Data System (ADS)

    Kocifaj, Miroslav; Petržala, Jaromír

    2016-11-01

    A zero-order approach to the solving of the radiative transfer equation and a method for obtaining the horizontal diffuse irradiance at night-time are both developed and intended for wide use in numerical predictions of nocturnal ground irradiance in populated territories. Downward diffuse radiative fluxes are computed with a two-stream approximation, and the data products obtained are useful for scientists who require rapid estimations of illumination levels during the night. The rapid technique presented here is especially important when the entire set of calculations is to be repeated for different lighting technologies and/or radiant intensity distributions with the aim of identifying high-level illuminance/irradiance, the spectral composition of scattered light or other optical properties of diffuse light at the ground level. The model allows for the computation of diffuse horizontal irradiance due to light emissions from ground-based sources with arbitrary spectral compositions. The optical response of a night sky is investigated using the ratio of downward to upward irradiance, R⊥, λ(0). We show that R⊥, λ(0) generally peaks at short wavelengths, thus suggesting that, e.g., the blue light of an LED lamp would make the sky even more bluish. However, this effect can be largely suppressed or even removed with the spectral sensitivity function of the average human eye superimposed on to the lamp spectrum. Basically, blue light scattering dominates at short optical distances, while red light is transmitted for longer distances and illuminates distant places. Computations are performed for unshielded as well as fully shielded lights, while the spectral function R⊥, λ(0) is tabulated to make possible the modelling of various artificial lights, including those not presented here.

  15. Silicon micromachined broad band light source

    NASA Technical Reports Server (NTRS)

    George, Thomas (Inventor); Jones, Eric (Inventor); Tuma, Margaret L. (Inventor); Eastwood, Michael (Inventor); Hansler, Richard (Inventor)

    2004-01-01

    A micro electromechanical system (MEMS) broad band incandescent light source includes three layers: a top transmission window layer; a middle filament mount layer; and a bottom reflector layer. A tungsten filament with a spiral geometry is positioned over a hole in the middle layer. A portion of the broad band light from the heated filament is reflective off the bottom layer. Light from the filament and the reflected light of the filament are transmitted through the transmission window. The light source may operate at temperatures of 2500 K or above. The light source may be incorporated into an on board calibrator (OBC) for a spectrometer.

  16. Polarization Dependent Whispering Gallery Modes in Microspheres

    NASA Technical Reports Server (NTRS)

    Adamovsky, Grigory (Inventor); Wrbanek, Susan Y. (Inventor)

    2016-01-01

    A tunable resonant system is provided and includes a microsphere that receives an incident portion of a light beam generated via a light source, the light beam having a fundamental mode, a waveguide medium that transmits the light beam from the light source to the microsphere, and a polarizer disposed in a path of the waveguide between the light source and the microsphere. The incident portion of the light beam creates a fundamental resonance inside the microsphere. A change in a normalized frequency of the wavelength creates a secondary mode in the waveguide and the secondary mode creates a secondary resonance inside the microsphere.

  17. Assessment of spatial information for hyperspectral imaging of lesion

    NASA Astrophysics Data System (ADS)

    Yang, Xue; Li, Gang; Lin, Ling

    2016-10-01

    Multiple diseases such as breast tumor poses a great threat to women's health and life, while the traditional detection method is complex, costly and unsuitable for frequently self-examination, therefore, an inexpensive, convenient and efficient method for tumor self-inspection is needed urgently, and lesion localization is an important step. This paper proposes an self-examination method for positioning of a lesion. The method adopts transillumination to acquire the hyperspectral images and to assess the spatial information of lesion. Firstly, multi-wavelength sources are modulated with frequency division, which is advantageous to separate images of different wavelength, meanwhile, the source serves as fill light to each other to improve the sensitivity in the low-lightlevel imaging. Secondly, the signal-to-noise ratio of transmitted images after demodulation are improved by frame accumulation technology. Next, gray distributions of transmitted images are analyzed. The gray-level differences is constituted by the actual transmitted images and fitting transmitted images of tissue without lesion, which is to rule out individual differences. Due to scattering effect, there will be transition zones between tissue and lesion, and the zone changes with wavelength change, which will help to identify the structure details of lesion. Finally, image segmentation is adopted to extract the lesion and the transition zones, and the spatial features of lesion are confirmed according to the transition zones and the differences of transmitted light intensity distributions. Experiment using flat-shaped tissue as an example shows that the proposed method can extract the space information of lesion.

  18. Voice intelligibility in satellite mobile communications

    NASA Technical Reports Server (NTRS)

    Wishna, S.

    1973-01-01

    An amplitude control technique is reported that equalizes low level phonemes in a satellite narrow band FM voice communication system over channels having low carrier to noise ratios. This method presents at the transmitter equal amplitude phonemes so that the low level phonemes, when they are transmitted over the noisey channel, are above the noise and contribute to output intelligibility. The amplitude control technique provides also for squelching of noise when speech is not being transmitted.

  19. Meteor burst communications for LPI applications

    NASA Astrophysics Data System (ADS)

    Schilling, D. L.; Apelewicz, T.; Lomp, G. R.; Lundberg, L. A.

    A technique that enhances the performance of meteor-burst communications is described. The technique, the feedback adaptive variable rate (FAVR) system, maintains a feedback channel that allows the transmitted bit rate to mimic the time behavior of the received power so that a constant bit energy is maintained. This results in a constant probability of bit error in each transmitted bit. Experimentally determined meteor-burst channel characteristics and FAVR system simulation results are presented.

  20. Optical Measurement of Mass Flow of a Two-Phase Fluid

    NASA Technical Reports Server (NTRS)

    Wiley, John; Pedersen, Kevin; Koman, Valentin; Gregory, Don

    2008-01-01

    An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

  1. Chemical analyses of fossil bone.

    PubMed

    Zheng, Wenxia; Schweitzer, Mary Higby

    2012-01-01

    The preservation of microstructures consistent with soft tissues, cells, and other biological components in demineralized fragments of dinosaur bone tens of millions of years old was unexpected, and counter to current hypotheses of tissue, cellular, and molecular degradation. Although the morphological similarity of these tissues to extant counterparts was unmistakable, after at least 80 million years exposed to geochemical influences, morphological similarity is insufficient to support an endogenous source. To test this hypothesis, and to characterize these materials at a molecular level, we applied multiple independent chemical, molecular, and microscopic analyses to identify the presence of original components produced by the extinct organisms. Microscopic techniques included field emission scanning electron microscopy, analytical transmission electron microscopy, transmitted light microscopy (LM), and fluorescence microscopy (FM). The chemical and molecular techniques include enzyme-linked immunosorbant assay, sodium dodecyl sulfate polyacrylamide gel electrophoresis, western blot (immunoblot), and attenuated total reflectance infrared spectroscopy. In situ analyses performed directly on tissues included immunohistochemistry and time-of-flight secondary ion mass spectrometry. The details of sample preparation and methodology are described in detail herein.

  2. Age estimation using tooth cementum annulation.

    PubMed

    Wittwer-Backofen, Ursula

    2012-01-01

    In Forensic Anthropology age diagnosis of unidentified bodies significantly helps in the identification process. Among the set of established aging methods in anthropology tooth cementum annulation (TCA) is increasingly used due to its narrow error range which can reach 5 years of age in adult individuals at best. The rhythm of cementum appositions of seasonally different density provides a principal mechanism on which TCA is based. Using histological preparation techniques for hard tissues, transversal tooth root sections are produced which can be analyzed in transmitted light microscopy. Even though no standard TCA preparation protocol exists, several methodological validation studies recommend specific treatments depending on individual conditions of the teeth. Individual age is estimated by adding mean tooth eruption age to the number of microscopically detected dark layers which are separated by bright layers and stand for 1 year of age each. To assure a high reliability of the method, TCA age diagnosis has to be based on several teeth of one individual if possible and needs to be supported by different techniques in forensic cases.

  3. High-Speed Photographic Study of Wave Propagation and Impact Damage in Fused Silica and AlON Using the Edge-On Impact (EOI) Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strassburger, E.; Patel, P.; McCauley, J. W.

    An Edge-on Impact (EOI) technique, developed at the Ernst-Mach-Institute (EMI), coupled with a Cranz-Schardin high-speed camera, has been successfully utilized to visualize dynamic fracture in many brittle materials. In a typical test, the projectile strikes one edge of a specimen and damage formation and fracture propagation is recorded during the first 20 {mu}s after impact. In the present study, stress waves and damage propagation in fused silica and AlON were examined by means of two modified Edge-on Impact arrangements. In one arrangement, fracture propagation was observed simultaneously in side and top views of the specimens by means of two Cranz-Schardinmore » cameras. In another arrangement, the photographic technique was modified by placing the specimen between crossed polarizers and using the photo-elastic effect to visualize the stress waves. Pairs of impact tests at approximately equivalent velocities were carried out in transmitted plane (shadowgraphs) and crossed polarized light.« less

  4. Simultaneous Airy beam generation for both surface plasmon polaritons and transmitted wave based on metasurface.

    PubMed

    Wang, Sen; Wang, Xinke; Zhang, Yan

    2017-10-02

    Based on the amplitude and phase modulation of subwavelength slits, a metasurface which can simultaneously generate Airy beam for surface plasmon polaritons (SPPs) and transmitted wave is presented. Interestingly, by changing the handedness of circularly polarized light, the position of SPPs Airy beam can be switched to the left or right side of the metasurface, while the field distribution and the position of the Airy beam for transmitted wave are not affected. The nondiffracting, self-bending and self-healing properties of the generated Airy beams are analyzed as well. In addition, abruptly autofocusing of SPPs and transmitted wave are demonstrated by interfering two Airy beams. The dual functionality and chirality features of the metasurface can provide more freedoms in the potential applications of Airy beams.

  5. Regression analysis for LED color detection of visual-MIMO system

    NASA Astrophysics Data System (ADS)

    Banik, Partha Pratim; Saha, Rappy; Kim, Ki-Doo

    2018-04-01

    Color detection from a light emitting diode (LED) array using a smartphone camera is very difficult in a visual multiple-input multiple-output (visual-MIMO) system. In this paper, we propose a method to determine the LED color using a smartphone camera by applying regression analysis. We employ a multivariate regression model to identify the LED color. After taking a picture of an LED array, we select the LED array region, and detect the LED using an image processing algorithm. We then apply the k-means clustering algorithm to determine the number of potential colors for feature extraction of each LED. Finally, we apply the multivariate regression model to predict the color of the transmitted LEDs. In this paper, we show our results for three types of environmental light condition: room environmental light, low environmental light (560 lux), and strong environmental light (2450 lux). We compare the results of our proposed algorithm from the analysis of training and test R-Square (%) values, percentage of closeness of transmitted and predicted colors, and we also mention about the number of distorted test data points from the analysis of distortion bar graph in CIE1931 color space.

  6. Simultaneous remote measurement of CO2 concentration, humidity and temperature with a matrix of optical fiber sensors

    NASA Astrophysics Data System (ADS)

    Wysokiński, Karol; Filipowicz, Marta; Stańczyk, Tomasz; Lipiński, Stanisław; Napierała, Marek; Murawski, Michał; Nasiłowski, Tomasz

    2017-10-01

    A matrix of optical fiber sensors eligible for remote measurements is reported in this paper. The aim of work was to monitor the air quality with a device, which does not need any electricity on site of the measurement. The matrix consists of several sensors detecting carbon dioxide concentration, relative humidity and temperature. Sensors utilize active optical materials, which change their color when exposed to varied conditions. All the sensors are powered with standard light emitting diodes. Light is transmitted by an optical fiber from the light source and then it reaches the active layer which changes its color, when the conditions change. This results in a change of attenuation of light passing through the active layer. Modified light is then transmitted by another optical fiber to the detector, where simple photoresistor is used. It is powered by a stabilized DC power supply and the current is measured. Since no expensive elements are needed to manufacture such a matrix of sensors, its price may be competitive to the price of the devices already available on the market, while the matrix also exhibits other valuable properties.

  7. System for determining position of normal shock in supersonic flow

    NASA Technical Reports Server (NTRS)

    Iverson, Jr., Donald G. (Inventor); Daiber, Troy D. (Inventor)

    1991-01-01

    Light from a plurality of light emitting diodes is transmitted through optical cables (12) to a lens system. The lenses (56, 58) expand and collimate the light and project it in a sheet (16) across the supersonic inlet of an aircraft power plant perpendicular to incoming airflow. A normal shock bends a portion of the sheet of light (16). A linear array of a multiplicity of optical fiber ends collects discrete samples of light. The samples are processed and compared to a predetermined profile to determine the shock location.

  8. Measuring the Photocatalytic Breakdown of Crystal Violet Dye using a Light Emitting Diode Approach

    NASA Technical Reports Server (NTRS)

    Ryan, Robert E.; Underwood, Lauren W.; O'Neal, Duane; Pagnutti, Mary; Davis, Bruce A.

    2009-01-01

    A simple method to estimate the photocatalytic reactivity performance of spray-on titanium dioxide coatings for transmissive glass surfaces was developed. This novel technique provides a standardized method to evaluate the efficiency of photocatalytic material systems over a variety of illumination levels. To date, photocatalysis assessments have generally been conducted using mercury black light lamps. Illumination levels for these types of lamps are difficult to vary, consequently limiting their use for assessing material performance under a diverse range of simulated environmental conditions. This new technique uses an ultraviolet (UV) gallium nitride (GaN) light emitting diode (LED) array instead of a traditional black light to initiate and sustain photocatalytic breakdown. This method was tested with a UV-resistant dye (crystal violet) applied to a titanium dioxide coated glass slide. Experimental control is accomplished by applying crystal violet to both titanium dioxide coated slides and uncoated control slides. A slide is illuminated by the UV LED array, at various light levels representative of outdoor and indoor conditions, from the dye side of the slide. To monitor degradation of the dye over time, a temperature-stabilized white light LED, whose emission spectrum overlaps with the dye absorption spectrum, is used to illuminate the opposite side of the slide. Using a spectrometer, the amount of light from the white light LED transmitted through the slide as the dye degrades is monitored as a function of wavelength and time and is subsequently analyzed. In this way, the rate of degradation for photocatalytically coated versus uncoated slide surfaces can be compared. Results demonstrate that the dye absorption decreased much more rapidly on the photocatalytically coated slides than on the control uncoated slides, and that dye degradation is dependent on illumination level. For photocatalytic activity assessment purposes, this experimental configuration and methodology minimizes many external variable effects and enables small changes in absorption to be measured. This research also compares the advantages of this innovative LED light source design over traditional mercury black light systems and non- LED lamp approaches. This novel technology begins to address the growing need for a standard method that can assess the performance of photocatalytic materials before deployment for large scale, real world use.

  9. A cascadable circular concentrator with parallel compressed structure for increasing the energy density

    NASA Astrophysics Data System (ADS)

    Ku, Nai-Lun; Chen, Yi-Yung; Hsieh, Wei-Che; Whang, Allen Jong-Woei

    2012-02-01

    Due to the energy crisis, the principle of green energy gains popularity. This leads the increasing interest in renewable energy such as solar energy. Thus, how to collect the sunlight for indoor illumination becomes our ultimate target. With the environmental awareness increasing, we use the nature light as the light source. Then we start to devote the development of solar collecting system. The Natural Light Guiding System includes three parts, collecting, transmitting and lighting part. The idea of our solar collecting system design is a concept for combining the buildings with a combination of collecting modules. Therefore, we can use it anyplace where the sunlight can directly impinges on buildings with collecting elements. In the meantime, while collecting the sunlight with high efficiency, we can transmit the sunlight into indoor through shorter distance zone by light pipe where we needs the light. We proposed a novel design including disk-type collective lens module. With the design, we can let the incident light and exit light be parallel and compressed. By the parallel and compressed design, we make every output light become compressed in the proposed optical structure. In this way, we can increase the ratio about light compression, get the better efficiency and let the energy distribution more uniform for indoor illumination. By the definition of "KPI" as an performance index about light density as following: lm/(mm)2, the simulation results show that the proposed Concentrator is 40,000,000 KPI much better than the 800,000 KPI measured from the traditional ones.

  10. Sol-Gel Glass Holographic Light-Shaping Diffusers

    NASA Technical Reports Server (NTRS)

    Yu, Kevin; Lee, Kang; Savant, Gajendra; Yin, Khin Swe (Lillian)

    2005-01-01

    Holographic glass light-shaping diffusers (GLSDs) are optical components for use in special-purpose illumination systems (see figure). When properly positioned with respect to lamps and areas to be illuminated, holographic GLSDs efficiently channel light from the lamps onto specified areas with specified distributions of illumination for example, uniform or nearly uniform irradiance can be concentrated with intensity confined to a peak a few degrees wide about normal incidence, over a circular or elliptical area. Holographic light diffusers were developed during the 1990s. The development of the present holographic GLSDs extends the prior development to incorporate sol-gel optical glass. To fabricate a holographic GLSD, one records a hologram on a sol-gel silica film formulated specially for this purpose. The hologram is a quasi-random, micro-sculpted pattern of smoothly varying changes in the index of refraction of the glass. The structures in this pattern act as an array of numerous miniature lenses that refract light passing through the GLSD, such that the transmitted light beam exhibits a precisely tailored energy distribution. In comparison with other light diffusers, holographic GLSDs function with remarkably high efficiency: they typically transmit 90 percent or more of the incident lamp light onto the designated areas. In addition, they can withstand temperatures in excess of 1,000 C. These characteristics make holographic GLSDs attractive for use in diverse lighting applications that involve high temperatures and/or requirements for high transmission efficiency for ultraviolet, visible, and near-infrared light. Examples include projectors, automobile headlights, aircraft landing lights, high-power laser illuminators, and industrial and scientific illuminators.

  11. Optical smart packaging to reduce transmitted information.

    PubMed

    Cabezas, Luisa; Tebaldi, Myrian; Barrera, John Fredy; Bolognini, Néstor; Torroba, Roberto

    2012-01-02

    We demonstrate a smart image-packaging optical technique that uses what we believe is a new concept to save byte space when transmitting data. The technique supports a large set of images mapped into modulated speckle patterns. Then, they are multiplexed into a single package. This operation results in a substantial decreasing of the final amount of bytes of the package with respect to the amount resulting from the addition of the images without using the method. Besides, there are no requirements on the type of images to be processed. We present results that proof the potentiality of the technique.

  12. Optical humidity sensor

    DOEpatents

    Tarvin, Jeffrey A.

    1987-01-01

    An optical dielectric humidity sensor which includes a dielectric mirror having multiple alternating layers of two porous water-adsorbent dielectric materials with differing indices of refraction carried by a translucent substrate. A narrow-band polarized light source is positioned to direct light energy onto the mirror, and detectors are positioned to receive light energy transmitted through and reflected by the mirror. A ratiometer indicates humidity in the atmosphere which surrounds the dielectric mirror as a function of a ratio of light energies incident on the detectors.

  13. Optical humidity sensor

    DOEpatents

    Tarvin, J.A.

    1987-02-10

    An optical dielectric humidity sensor is disclosed which includes a dielectric mirror having multiple alternating layers of two porous water-adsorbent dielectric materials with differing indices of refraction carried by a translucent substrate. A narrow-band polarized light source is positioned to direct light energy onto the mirror, and detectors are positioned to receive light energy transmitted through and reflected by the mirror. A ratiometer indicates humidity in the atmosphere which surrounds the dielectric mirror as a function of a ratio of light energies incident on the detectors. 2 figs.

  14. Dynamic Optical Grating Device and Associated Method for Modulating Light

    NASA Technical Reports Server (NTRS)

    Park, Yeonjoon (Inventor); Choi, Sang H. (Inventor); King, Glen C. (Inventor); Chu, Sang-Hyon (Inventor)

    2012-01-01

    A dynamic optical grating device and associated method for modulating light is provided that is capable of controlling the spectral properties and propagation of light without moving mechanical components by the use of a dynamic electric and/or magnetic field. By changing the electric field and/or magnetic field, the index of refraction, the extinction coefficient, the transmittivity, and the reflectivity fo the optical grating device may be controlled in order to control the spectral properties of the light reflected or transmitted by the device.

  15. Postquench prethermalization in a disordered quantum fluid of light

    NASA Astrophysics Data System (ADS)

    Larré, Pierre-Élie; Delande, Dominique; Cherroret, Nicolas

    2018-04-01

    We study the coherence of a disordered and interacting quantum light field after propagation along a nonlinear optical fiber. Disorder is generated by a cross-phase modulation with a randomized auxiliary classical light field, while interactions are induced by self-phase modulation. When penetrating the fiber from free space, the incoming quantum light undergoes a disorder and interaction quench. By calculating the coherence function of the transmitted quantum light, we show that the decoherence induced by the quench spreads in a light-cone fashion in the nonequilibrium many-body quantum system, leaving the latter prethermalize with peculiar features originating from disorder.

  16. Photoconductive method for measuring light transmission to the root of metal-ceramic and all-ceramic restorations.

    PubMed

    Hsieh, Yun-Lin; Lai, Yu-Lin; Chen, Hui-Lin; Hung, Cheng-Yuan; Chen, Xiu-Ling; Lee, Shyh-Yuan

    2008-09-01

    In this study, the authors attempted to develop a photoconductive method for measuring light transmission through a crown restoration to the root dentin; metal-ceramic crowns with four coping designs (metal collar, and metal framework ending 0, 1, and 2mm coronal to the axiogingival line angle) and two all-ceramic crowns (Empress II and In-Ceram Alumina) were compared. According to pre-registered templates, 36 crowns were fabricated for an extracted central incisor. A cadmium sulfide (CdS) photoconductive cell was secured onto the root of a tooth, which was fixed in a light box. The validity and reliability of the experimental design were verified, and the impedance of the cell was recorded when the crowns were placed on the prepared tooth with or without try-in pastes under a constant luminance. A significant correlation (r= -0.99, p<0.001) was found between the light intensity and impedance of the CdS cell, and a 1.15% coefficient of variation between repeated measurements was observed. In this study, Empress II crowns had the smallest impedance, indicating that they provided the best light transmission. Conventional metal-ceramic crowns had the least light transmission, which was significantly improved by reducing the metal collar (p<0.05). The framework of metal-ceramic crowns which ended 2mm coronal to the axiogingival line angle showed as much light transmission as the In-Ceram crowns. The impedance increased when try-in pastes were employed in all test groups. The photoconductive method was proven to be a reliable technique for measuring the light transmitted through restorations into the adjacent tissue.

  17. Telemetry with an Optical Fiber Revisited: An Alternative Strategy

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2014-01-01

    With a new data-acquisition system developed by PASCO scientific, an experiment on telemetry with an optical fiber can be made easier and more accurate. For this aim, an alternative strategy of the remote temperature measurements is proposed: the frequency of light pulses transmitted via the light guide numerically equals the temperature using…

  18. Career Directions--Fiber Optic Installer

    ERIC Educational Resources Information Center

    Tech Directions, 2012

    2012-01-01

    Fiber-optic communication is a method of transmitting information from one place to another by sending pulses of light through an optical fiber that is roughly the diameter of a human hair. The light forms an electromagnetic carrier wave that is modulated to carry information. Each optical fiber is capable of carrying an enormous amount of…

  19. A photoelectric skylight polarimeter.

    PubMed

    Hariharan, T A; Sekera, Z

    1966-09-01

    A photoelectric skylight polarimeter to measure directly the Stokes parameters for plane polarized light is described. The basic principle of the instrument consists in the simultaneous measurement of the intensity of light (in the chosen spectral region) transmitted by polarizers oriented in four specific directions. The main features and performance characteristics of the instrument are briefly discussed.

  20. Wireless Computers: Radio and Light Communications May Bring New Freedom to Computing.

    ERIC Educational Resources Information Center

    Hartmann, Thom

    1984-01-01

    Describes systems which use wireless terminals to communicate with mainframe computers or minicomputers via radio band, discusses their limitations, and gives examples of networks using such systems. The use of communications satellites to increase their range and the possibility of using light beams to transmit data are also discussed. (MBR)

  1. Method of fabricating a 3-dimensional tool master

    DOEpatents

    Bonivert, William D.; Hachman, John T.

    2002-01-01

    The invention is a method for the fabrication of an imprint tool master. The process begins with a metallic substrate. A layer of photoresist is placed onto the metallic substrate and a image pattern mask is then aligned to the mask. The mask pattern has opaque portions that block exposure light and "open" or transparent portions which transmit exposure light. The photoresist layer is then exposed to light transmitted through the "open" portions of the first image pattern mask and the mask is then removed. A second layer of photoresist then can be placed onto the first photoresist layer and a second image pattern mask may be placed on the second layer of photoresist. The second layer of photoresist is exposed to light, as before, and the second mask removed. The photoresist layers are developed simultaneously to produce a multi-level master mandrel upon which a conductive film is formed. A tool master can now be formed onto the conductive film. An imprint tool is then produced from the tool master. In one embodiment, nickel is electroplated onto the tool master to produce a three-dimensional imprint tool.

  2. Device for collecting and analyzing matrix-isolated samples

    DOEpatents

    Reedy, Gerald T.

    1979-01-01

    A gas-sample collection device is disclosed for matrix isolation of individual gas bands from a gas chromatographic separation and for presenting these distinct samples for spectrometric examination. The device includes a vacuum chamber containing a rotatably supported, specular carrousel having a number of external, reflecting surfaces around its axis of rotation for holding samples. A gas inlet is provided for depositing sample and matrix material on the individual reflecting surfaces maintained at a sufficiently low temperature to cause solidification. Two optical windows or lenses are installed in the vacuum chamber walls for transmitting a beam of electromagnetic radiation, for instance infrared light, through a selected sample. Positioned within the chamber are two concave mirrors, the first aligned to receive the light beam from one of the lenses and focus it to the sample on one of the reflecting surfaces of the carrousel. The second mirror is aligned to receive reflected light from that carrousel surface and to focus it outwardly through the second lens. The light beam transmitted from the sample is received by a spectrometer for determining absorption spectra.

  3. Effect of atmospheric refraction on radiative transfer in visible and near-infrared band: Model development, validation, and applications

    NASA Astrophysics Data System (ADS)

    Hu, Shuai; Gao, Tai-chang; Li, Hao; Liu, Lei; Liu, Xi-chuan; Zhang, Ting; Cheng, Tian-ji; Li, Wan-tong; Dai, Zhong-hua; Su, Xiaojian

    2016-03-01

    Refraction is an important factor influencing radiative transfer since it can modify the propagation trajectory and polarization states of lights; therefore, it is necessary to quantitively evaluate the effect of atmospheric refraction on radiative transfer process. To this end, a new atmospheric radiative transfer model including refraction process is proposed. The model accuracy is validated against benchmark results, literature results, and well-tested radiative transfer models such as discrete coordinate method and RT3/PolRadtran. The impact of atmospheric refraction on both polarized radiance and fluxes is discussed for pure Rayleigh scattering atmosphere, atmosphere with aerosol, and cloud. The results show that atmospheric refraction has a significant influence on both the radiance and polarization states of diffuse light, where the relative change of the radiance of reflected light and transmitted light due to refraction can achieve 6.3% and 7.4% for Rayleigh scattering atmosphere, 7.2% and 7.8% for atmosphere with aerosol, and 6.2% and 6.8% for cloudy atmosphere, respectively. The relative change of the degree of polarization ranges from near zero in the horizon to 9.5% near neutral points. The angular distribution pattern of the relative change of the radiance for atmosphere with aerosol and cloud is very similar to that for pure Rayleigh scattering case, where its magnitude decreases gradually with the increasing of zenith angle for reflected light; but for transmitted light, the variation characteristics is opposite. The impact of refraction is gradually enhanced with the increasing of solar zenith angles and the optical depth of aerosol and cloud. As the wavelength of incident light increases, the impact declines rapidly for Rayleigh scattering medium. The relative change of the fluxes due to refraction is most notable for Middle Latitude Winter profile (about 8.2043% and 7.3225% for the transmitted and reflected light, respectively, at 0.35 µm). With increasing the optical depth of aerosol, the influence of refraction on the fluxes is gradually enhanced. For cloudy atmosphere, the relative changes of the fluxes due to refraction are not very sensitive to the variation of cloud optical depth and effective radius of cloud drops.

  4. Arrays of strongly coupled atoms in a one-dimensional waveguide

    NASA Astrophysics Data System (ADS)

    Ruostekoski, Janne; Javanainen, Juha

    2017-09-01

    We study the cooperative optical coupling between regularly spaced atoms in a one-dimensional waveguide using decompositions to subradiant and super-radiant collective excitation eigenmodes, direct numerical solutions, and analytical transfer-matrix methods. We illustrate how the spectrum of transmitted light through the waveguide, including the emergence of narrow Fano resonances, can be understood by the resonance features of the eigenmodes. We describe a method based on super-radiant and subradiant modes to engineer the optical response of the waveguide and to store light. The stopping of light is obtained by transferring an atomic excitation to a subradiant collective mode with the zero radiative resonance linewidth by controlling the level shift of an atom in the waveguide. Moreover, we obtain an exact analytic solution for the transmitted light through the waveguide for the case of a regular lattice of atoms and provide a simple description of how the light transmission may present large resonance shifts when the lattice spacing is close, but not exactly equal, to half of the wavelength of the light. Experimental imperfections such as fluctuations of the positions of the atoms and loss of light from the waveguide are easily quantified in the numerical simulations, which produce the natural result that the optical response of the atomic array tends toward the response of a gas with random atomic positions.

  5. Technique to separate lidar signal and sunlight.

    PubMed

    Sun, Wenbo; Hu, Yongxiang; MacDonnell, David G; Weimer, Carl; Baize, Rosemary R

    2016-06-13

    Sunlight contamination dominates the backscatter noise in space-based lidar measurements during daytime. The background scattered sunlight is highly variable and dependent upon the surface and atmospheric albedo. The scattered sunlight contribution to noise increases over land and snow surfaces where surface albedos are high and thus overwhelm lidar backscatter from optically thin atmospheric constituents like aerosols and thin clouds. In this work, we developed a novel lidar remote sensing concept that potentially can eliminate sunlight induced noise. The new lidar concept requires: (1) a transmitted laser light that carries orbital angular momentum (OAM); and (2) a photon sieve (PS) diffractive filter that separates scattered sunlight from laser light backscattered from the atmosphere, ocean and solid surfaces. The method is based on numerical modeling of the focusing of Laguerre-Gaussian (LG) laser beam and plane-wave light by a PS. The model results show that after passing through a PS, laser light that carries the OAM is focused on a ring (called "focal ring" here) on the focal plane of the PS filter, very little energy arrives at the center of the focal plane. However, scattered sunlight, as a plane wave without the OAM, focuses at the center of the focal plane and thus can be effectively blocked or ducted out. We also find that the radius of the "focal ring" increases with the increase of azimuthal mode (L) of LG laser light, thus increasing L can more effectively separate the lidar signal away from the sunlight noise.

  6. Multimodal optical setup based on spectrometer and cameras combination for biological tissue characterization with spatially modulated illumination

    NASA Astrophysics Data System (ADS)

    Baruch, Daniel; Abookasis, David

    2017-04-01

    The application of optical techniques as tools for biomedical research has generated substantial interest for the ability of such methodologies to simultaneously measure biochemical and morphological parameters of tissue. Ongoing optimization of optical techniques may introduce such tools as alternative or complementary to conventional methodologies. The common approach shared by current optical techniques lies in the independent acquisition of tissue's optical properties (i.e., absorption and reduced scattering coefficients) from reflected or transmitted light. Such optical parameters, in turn, provide detailed information regarding both the concentrations of clinically relevant chromophores and macroscopic structural variations in tissue. We couple a noncontact optical setup with a simple analysis algorithm to obtain absorption and scattering coefficients of biological samples under test. Technically, a portable picoprojector projects serial sinusoidal patterns at low and high spatial frequencies, while a spectrometer and two independent CCD cameras simultaneously acquire the reflected diffuse light through a single spectrometer and two separate CCD cameras having different bandpass filters at nonisosbestic and isosbestic wavelengths in front of each. This configuration fills the gaps in each other's capabilities for acquiring optical properties of tissue at high spectral and spatial resolution. Experiments were performed on both tissue-mimicking phantoms as well as hands of healthy human volunteers to quantify their optical properties as proof of concept for the present technique. In a separate experiment, we derived the optical properties of the hand skin from the measured diffuse reflectance, based on a recently developed camera model. Additionally, oxygen saturation levels of tissue measured by the system were found to agree well with reference values. Taken together, the present results demonstrate the potential of this integrated setup for diagnostic and research applications.

  7. Nanoantenna harmonic sensor: theoretical analysis of contactless detection of molecules with light

    NASA Astrophysics Data System (ADS)

    Farhat, Mohamed; Cheng, Mark M. C.; Le, Khai Q.; Chen, Pai-Yen

    2015-10-01

    The nonlinear harmonic sensor is a popular wireless sensor and radiofrequency identification (RFID) technique, which allows high-performance sensing in a severe interference/clutter background by transmitting a radio wave and detecting its modulated higher-order harmonics. Here we introduce the concept and design of optical harmonic tags based on nonlinear nanoantennas that can contactlessly detect electronic (e.g. electron affinity) and optical (e.g. relative permittivity) characteristics of molecules. By using a dual-resonance gold-molecule-silver nanodipole antenna within the quantum mechanical realm, the spectral form of the second-harmonic scattering can sensitively reveal the physical properties of molecules, paving a new route towards optical molecular sensors and optical identification (OPID) of biological, genetic, and medical events for the ‘Internet of Nano-Things’.

  8. Nanoantenna harmonic sensor: theoretical analysis of contactless detection of molecules with light.

    PubMed

    Farhat, Mohamed; Cheng, Mark M C; Le, Khai Q; Chen, Pai-Yen

    2015-10-16

    The nonlinear harmonic sensor is a popular wireless sensor and radiofrequency identification (RFID) technique, which allows high-performance sensing in a severe interference/clutter background by transmitting a radio wave and detecting its modulated higher-order harmonics. Here we introduce the concept and design of optical harmonic tags based on nonlinear nanoantennas that can contactlessly detect electronic (e.g. electron affinity) and optical (e.g. relative permittivity) characteristics of molecules. By using a dual-resonance gold-molecule-silver nanodipole antenna within the quantum mechanical realm, the spectral form of the second-harmonic scattering can sensitively reveal the physical properties of molecules, paving a new route towards optical molecular sensors and optical identification (OPID) of biological, genetic, and medical events for the 'Internet of Nano-Things'.

  9. Design considerations for a backlight with switchable viewing angles

    NASA Astrophysics Data System (ADS)

    Fujieda, Ichiro; Takagi, Yoshihiko; Rahadian, Fanny

    2006-08-01

    Small-sized liquid crystal displays are widely used for mobile applications such as cell phones. Electronic control of a viewing angle range is desired in order to maintain privacy for viewing in public as well as to provide wide viewing angles for solitary viewing. Conventionally, a polymer-dispersed liquid crystal (PDLC) panel is inserted between a backlight and a liquid crystal panel. The PDLC layer either transmits or scatters the light from the backlight, thus providing an electronic control of viewing angles. However, such a display system is obviously thick and expensive. Here, we propose to place an electronically-controlled, light-deflecting device between an LED and a light-guide of a backlight. For example, a liquid crystal lens is investigated for other applications and its focal length is controlled electronically. A liquid crystal phase grating either transmits or diffracts an incoming light depending on whether or not a periodic phase distribution is formed inside its liquid crystal layer. A bias applied to such a device will control the angular distribution of the light propagating inside a light-guide. Output couplers built in the light-guide extract the propagating light to outside. They can be V-shaped grooves, pyramids, or any other structures that can refract, reflect or diffract light. When any of such interactions occur, the output couplers translate the changes in the propagation angles into the angular distribution of the output light. Hence the viewing-angle characteristic can be switched. The designs of the output couplers and the LC devices are important for such a backlight system.

  10. Evaluation of Eye Protection Filters Used with Broad-Spectrum and Conventional LED Curing Lights.

    PubMed

    Soares, Carlos José; Rodrigues, Monise de Paula; Vilela, Andomar Bruno Fernandes; Rizo, Erick René Cerda; Ferreira, Lorraine Braga; Giannini, Marcelo; Price, Richard Bengt

    2017-01-01

    The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.

  11. Long-distance transmission of light in a scintillator-based radiation detector

    DOEpatents

    Dowell, Jonathan L.; Talbott, Dale V.; Hehlen, Markus P.

    2017-07-11

    Scintillator-based radiation detectors capable of transmitting light indicating the presence of radiation for long distances are disclosed herein. A radiation detector can include a scintillator layer and a light-guide layer. The scintillator layer is configured to produce light upon receiving incident radiation. The light-guide layer is configured to receive light produced by the scintillator layer and either propagate the received light through the radiation detector or absorb the received light and emit light, through fluorescence, that is propagated through the radiation detector. A radiation detector can also include an outer layer partially surrounding the scintillator layer and light-guide layer. The index of refraction of the light-guide layer can be greater than the index of refraction of adjacent layers.

  12. Modernized Approach for Generating Reproducible Heterogeneity Using Transmitted-Light for Flow Visualization Experiments

    NASA Astrophysics Data System (ADS)

    Jones, A. A.; Holt, R. M.

    2017-12-01

    Image capturing in flow experiments has been used for fluid mechanics research since the early 1970s. Interactions of fluid flow between the vadose zone and permanent water table are of great interest because this zone is responsible for all recharge waters, pollutant transport and irrigation efficiency for agriculture. Griffith, et al. (2011) developed an approach where constructed reproducible "geologically realistic" sand configurations are deposited in sandfilled experimental chambers for light-transmitted flow visualization experiments. This method creates reproducible, reverse graded, layered (stratified) thin-slab sand chambers for point source experiments visualizing multiphase flow through porous media. Reverse-graded stratification of sand chambers mimic many naturally occurring sedimentary deposits. Sandfilled chambers use light as nonintrusive tools for measuring water saturation in two-dimensions (2-D). Homogeneous and heterogeneous sand configurations can be produced to visualize the complex physics of the unsaturated zone. The experimental procedure developed by Griffith, et al. (2011) was designed using now outdated and obsolete equipment. We have modernized this approach with new Parker Deadel linear actuator and programed projects/code for multiple configurations. We have also updated the Roper CCD software and image processing software with the latest in industry standards. Modernization of transmitted-light source, robotic equipment, redesigned experimental chambers, and newly developed analytical procedures have greatly reduced time and cost per experiment. We have verified the ability of the new equipment to generate reproducible heterogeneous sand-filled chambers and demonstrated the functionality of the new equipment and procedures by reproducing several gravity-driven fingering experiments conducted by Griffith (2008).

  13. Multi-channel infrared thermometer

    DOEpatents

    Ulrickson, M.A.

    A device for measuring the two-dimensional temperature profile of a surface comprises imaging optics for generating an image of the light radiating from the surface; an infrared detector array having a plurality of detectors; and optical means positioned between the imaging optics and the detector array for sampling, transmitting, and distributing the image over the detector surfaces. The optical means may be a light pipe array having one light pipe for each detector in the detector array.

  14. Optical keyboard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veligdan, James T.; Feichtner, John D.; Phillips, Thomas E.

    2001-01-01

    An optical keyboard includes an optical panel having optical waveguides stacked together. First ends of the waveguides define an inlet face, and opposite ends thereof define a screen. A projector transmits a light beam outbound through the waveguides for display on the screen as a keyboard image. A light sensor is optically aligned with the inlet face for sensing an inbound light beam channeled through the waveguides from the screen upon covering one key of the keyboard image.

  15. Optical Processing Techniques For Pseudorandom Sequence Prediction

    NASA Astrophysics Data System (ADS)

    Gustafson, Steven C.

    1983-11-01

    Pseudorandom sequences are series of apparently random numbers generated, for example, by linear or nonlinear feedback shift registers. An important application of these sequences is in spread spectrum communication systems, in which, for example, the transmitted carrier phase is digitally modulated rapidly and pseudorandomly and in which the information to be transmitted is incorporated as a slow modulation in the pseudorandom sequence. In this case the transmitted information can be extracted only by a receiver that uses for demodulation the same pseudorandom sequence used by the transmitter, and thus this type of communication system has a very high immunity to third-party interference. However, if a third party can predict in real time the probable future course of the transmitted pseudorandom sequence given past samples of this sequence, then interference immunity can be significantly reduced.. In this application effective pseudorandom sequence prediction techniques should be (1) applicable in real time to rapid (e.g., megahertz) sequence generation rates, (2) applicable to both linear and nonlinear pseudorandom sequence generation processes, and (3) applicable to error-prone past sequence samples of limited number and continuity. Certain optical processing techniques that may meet these requirements are discussed in this paper. In particular, techniques based on incoherent optical processors that perform general linear transforms or (more specifically) matrix-vector multiplications are considered. Computer simulation examples are presented which indicate that significant prediction accuracy can be obtained using these transforms for simple pseudorandom sequences. However, the useful prediction of more complex pseudorandom sequences will probably require the application of more sophisticated optical processing techniques.

  16. Method and apparatus for removing unwanted reflections from an interferometer

    NASA Technical Reports Server (NTRS)

    Steimle, Lawrence J. (Inventor); Thiessen, David L. (Inventor)

    1994-01-01

    A device for eliminating unwanted reflections from refractive optical elements in an optical system is provided. The device operates to prevent desired multiple fringe patterns from being obscured by reflections from refractive elements positioned in proximity to a focal plane of the system. The problem occurs when an optical beam is projected into, and reflected back out of, the optical system. Surfaces of the refractive elements reflect portions of the beam which interfere with portions of the beam which are transmitted through the refractive elements. Interference between the reflected and transmitted portions of the beam produce multiple fringe sets which tend to obscure desired interference fringes. With the refractive optical element in close proximity to the focal plane of the system, the undesired reflected light reflects at an angle 180 degrees opposite from the desired transmitted beam. The device exploits the 180-degree offset, or rotational shear, of the undesired reflected light by providing an optical stop for blocking one-half of the cross-section of the test beam. By blocking one-half of the test beam, the undesired offset beam is blocked, while the returning transmitted beam passes into the optical system unaffected. An image is thereby produced from only the desired transmitted beam. In one configuration, the blocking device includes a semicircular aperture which is caused to rotate about the axis of the test beam. By rotating, all portions of the test beam are cyclically projected into the optical system to thereby produce a complete test image. The rotating optical stop is preferably caused to rotate rapidly to eliminate flicker in the resulting image.

  17. Millimeter spatial resolution in vivo sodium MRI of the human eye at 7 T using a dedicated radiofrequency transceiver array.

    PubMed

    Wenz, Daniel; Kuehne, Andre; Huelnhagen, Till; Nagel, Armin M; Waiczies, Helmar; Weinberger, Oliver; Oezerdem, Celal; Stachs, Oliver; Langner, Soenke; Seeliger, Erdmann; Flemming, Bert; Hodge, Russell; Niendorf, Thoralf

    2018-08-01

    The aim of this study was to achieve millimeter spatial resolution sodium in vivo MRI of the human eye at 7 T using a dedicated six-channel transceiver array. We present a detailed description of the radiofrequency coil design, along with electromagnetic field and specific absorption ratio simulations, data validation, and in vivo application. Electromagnetic field and specific absorption ratio simulations were performed. Transmit field uniformity was optimized by using a multi-objective genetic algorithm. Transmit field mapping was conducted using a phase-sensitive method. An in vivo feasibility study was carried out with 3-dimensional density-adapted projection reconstruction imaging technique. Measured transmit field distribution agrees well with the one obtained from simulations. The specific absorption ratio simulations confirm that the radiofrequency coil is safe for clinical use. Our radiofrequency coil is light and conforms to an average human head. High spatial resolution (nominal 1.4 and 1.0 mm isotropic) sodium in vivo images of the human eye were acquired within scan times suitable for clinical applications (∼ 10 min). Three most important eye compartments in the context of sodium physiology were clearly delineated in all of the images: the vitreous humor, the aqueous humor, and the lens. Our results provide encouragement for further clinical studies. The implications for research into eye diseases including ocular melanoma, cataract, and glaucoma are discussed. Magn Reson Med 80:672-684, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  18. Care System Versus Transmitted Light Wavefront Pattern of Contact Lenses.

    PubMed

    Chiericati, Stefano; Borghesi, Alessandro; Cozza, Federica; Ferraro, Lorenzo; Acciarri, Maurizio; Farris, Stefano; Tavazzi, Silvia

    2017-05-01

    This article compares the optical performance of soft contact lenses (CLs) treated with multipurpose or hydrogen peroxide care systems. The investigated care systems were (1) 3% hydrogen peroxide solution Oxysept (Abbot Medical Optics, Abbott Park, IL) and (2) multipurpose solution Regard (Vita Research, Ariccia, Italy). Three types of silicone hydrogel CLs were studied (comfilcon A, lotrafilcon B, and balafilcon A), unworn and exposed for 30 times to the solutions, which were replaced every 8 hr. The optical performance of the CLs was evaluated through the on-eye transmitted light wavefront patterns by considering new CLs as references. The surface morphology of the CLs was investigated by scanning electron microscopy. Statistically significant modifications in the range 0.1 to 0.3 μm of Zernicke coefficients and modifications of the root mean square of the wavefront aberration function were found for CLs treated with multipurpose solution, in agreement with the observed modifications of the surface morphology. Statistically significant changes were also found after exposure to the hydrogen peroxide solution, but the variation of the Zernicke coefficients was found lower than 0.1 μm, thus being negligible in CL optical performances. In addition to disinfection ability and ocular surface reactions, CL care systems are different in solution-related CL optical performance. Multipurpose solutions may affect the CL surface morphology with significant modifications of the transmitted light wavefront pattern.

  19. Stigma and stereotypes: women and sexually transmitted infections.

    PubMed

    East, Leah; Jackson, Debra; O'Brien, Louise; Peters, Kathleen

    2012-01-01

    Sexually transmitted infections have long been associated with stigma and stereotypes due to their very nature. Throughout history sexually transmitted infections have been associated with female prostitution and deviant immoral behaviour making women who contract these infections particularly vulnerable to being stigmatised and stereotyped. Although the stigma attached to such infections has previously been documented in the literature, the aim of this research was to gain in depth insight into young Australian women's experiences of having a sexually transmitted infection from a feminist perspective. Findings from this study provide insight into the onerous effects stigma can have on women with these infections and sheds light on how these effects can influence self-perceptions, fear of rejection and feelings of unworthiness. These findings can provide nurses with greater understanding and insight into the effects of stigma on women's experiences of having a sexually transmitted infection. Having this understanding and insight has the potential to promote therapeutic care and minimise the stigma that may be felt among women who have contracted this type of infection.

  20. Testing of a Fiber Optic Wear, Erosion and Regression Sensor

    NASA Technical Reports Server (NTRS)

    Korman, Valentin; Polzin, Kurt A.

    2011-01-01

    The nature of the physical processes and harsh environments associated with erosion and wear in propulsion environments makes their measurement and real-time rate quantification difficult. A fiber optic sensor capable of determining the wear (regression, erosion, ablation) associated with these environments has been developed and tested in a number of different applications to validate the technique. The sensor consists of two fiber optics that have differing attenuation coefficients and transmit light to detectors. The ratio of the two measured intensities can be correlated to the lengths of the fiber optic lines, and if the fibers and the host parent material in which they are embedded wear at the same rate the remaining length of fiber provides a real-time measure of the wear process. Testing in several disparate situations has been performed, with the data exhibiting excellent qualitative agreement with the theoretical description of the process and when a separate calibrated regression measurement is available good quantitative agreement is obtained as well. The light collected by the fibers can also be used to optically obtain the spectra and measure the internal temperature of the wear layer.

  1. Simple diagnosis of HbA1c using the dual-plasmonic platform integrated with LSPR and SERS

    NASA Astrophysics Data System (ADS)

    Heo, Nam Su; Kwak, Cheol Hwan; Lee, Hoomin; Kim, Dongjoo; Lee, Sunmook; Kim, Gi-bum; Kwon, Soonjo; Kim, Woo Sik; Huh, Yun Suk

    2017-07-01

    A plasmonic active chip was designed with a transparent polymer film self-assembled with gold nanoparticles (AuNPs). In this study, we demonstrated the feasibility and sensitivity of biosensors by employing a plasmonic resonance technique. AuNPs are widely used as biosensing probes because they facilitate stable immobilization of biomolecules. Transparent polymer film facilitated measurement of changes in absorbance via transmitted light and analysis of Raman scattering via scattered light. The cysteine rich protein G and anti-HbA1c were sequentially conjugated to self-assembled AuNPs on the transparent polymer film to detect a target protein. HbA1c, which is used as an indicator for diabetes diagnosis, was selected for target protein detection. We confirmed the linearly increased absorbance values with increasing HbA1c level (3.19-14.0%) by LSPR detection. We also verified the linear increase in SERS intensity as the concentration of anti-Hb increased from 10 ng mL-1 to 1 μg mL-1 by analyzing the SERS spectra of Cy3 labeled anti-Hb added substrates.

  2. 77 FR 8722 - Airworthiness Directives; Eurocopter Deutschland Model EC135 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    ... that in the past, the FADEC FAIL caution light illuminated on a few EC135 T1 helicopters. It states... metering unit and transmitted to the FADEC. This discrepancy led to the display of the FADEC FAIL caution... the FADEC to automatically meter fuel, indicated by a FADEC FAIL cockpit caution light, and subsequent...

  3. Evaluation of spectral light management on growth of container-grown willow oak, nuttall oak and summer red maple

    USDA-ARS?s Scientific Manuscript database

    Plant response to blue, red, gray or black shade cloth was evaluated with willow oak (Quercus phellos L.), Nuttall oak (Quercus nuttallii Palmer, Nuttall) and Summer Red maple (Acer rubrum L. ‘Summer Red’) liners. Light transmitted through the colored shade cloth had no influence on germination of ...

  4. Combining Ultrasound Pulse-Echo and Transmission Computed Tomography for Quantitative Imaging the Cortical Shell of Long Bone Replicas

    NASA Astrophysics Data System (ADS)

    Shortell, Matthew P.; Althomali, Marwan A. M.; Wille, Marie-Luise; Langton, Christian M.

    2017-11-01

    We demonstrate a simple technique for quantitative ultrasound imaging of the cortical shell of long bone replicas. Traditional ultrasound computed tomography instruments use the transmitted or reflected waves for separate reconstructions but suffer from strong refraction artefacts in highly heterogenous samples such as bones in soft tissue. The technique described here simplifies the long bone to a two-component composite and uses both the transmitted and reflected waves for reconstructions, allowing the speed of sound and thickness of the cortical shell to be calculated accurately. The technique is simple to implement, computationally inexpensive and sample positioning errors are minimal.

  5. Wavefront image sensor chip

    PubMed Central

    Cui, Xiquan; Ren, Jian; Tearney, Guillermo J.; Yang, Changhuei

    2010-01-01

    We report the implementation of an image sensor chip, termed wavefront image sensor chip (WIS), that can measure both intensity/amplitude and phase front variations of a light wave separately and quantitatively. By monitoring the tightly confined transmitted light spots through a circular aperture grid in a high Fresnel number regime, we can measure both intensity and phase front variations with a high sampling density (11 µm) and high sensitivity (the sensitivity of normalized phase gradient measurement is 0.1 mrad under the typical working condition). By using WIS in a standard microscope, we can collect both bright-field (transmitted light intensity) and normalized phase gradient images. Our experiments further demonstrate that the normalized phase gradient images of polystyrene microspheres, unstained and stained starfish embryos, and strongly birefringent potato starch granules are improved versions of their corresponding differential interference contrast (DIC) microscope images in that they are artifact-free and quantitative. Besides phase microscopy, WIS can benefit machine recognition, object ranging, and texture assessment for a variety of applications. PMID:20721059

  6. Nondestructive measurement of an optical fiber refractive-index profile by a transmitted-light differential interference contact microscope.

    PubMed

    Liu, Zhongyao; Dong, Xiaoman; Chen, Qianghua; Yin, Chunyong; Xu, Yuxian; Zheng, Yingjun

    2004-03-01

    A novel transmitted-light differential interference contrast (DIC) system is used for nondestructive measurement of the refractive-index profile (RIP) of an optical fiber. By means of this system the phase of a measured light beam can be modulated with an analyzer, and the phase distribution of a fiber is obtained by calculation of the various interference patterns. The measurement theory and structure and some typical applications of this system are demonstrated. The results of measuring RIPs in graded-index fiber are presented. Both the experimental results and theoretical analysis show that the system takes the advantage of high index resolution and of sufficient measurement accuracy for measuring the refractive index of the optical fiber. The system has strong ability to overcome environmental disturbance because of its common-path design. Moreover, one can use the system to measure the RIP along the fiber axis and acquire an image of the three-dimensional RIP of the fiber.

  7. Speckle-Suppression Apparatus

    NASA Technical Reports Server (NTRS)

    Taback, Israel

    1989-01-01

    Technique and apparatus developed to reduce speckle in unmodulated laser pulses, using reduced number of optical fibers. Expected to decrease costs of bundles of optical fibers used to transmit unmodulated laser pulses. New apparatus reduces speckle in optically transmitted, unmodulated laser input pulse by introducing number of independent delays into pulse.

  8. The assessment of sympathetic activity using iPPG based inter-limb coherence measurements

    NASA Astrophysics Data System (ADS)

    Tsoy, Maria O.; Rogatina, Kristina V.; Stiukhina, Elena S.; Postnov, Dmitry E.

    2017-04-01

    Photoplethysmography is an optical technique that can be used to detect blood volume changes and to measure important physiological parameters. This is low cost and non-invasive technique. However, one has to apply sensor directly to the skin. In this regard, the development on remote mothods receives the growing attention, such as imaging photoplethysmography (iPPG). Note, most of public-available iPPG systems are based on smartphone-embedded cameras, and thus have a sample frequency about 30-60 frames per second, which is enough for heart rate measurements, but may be too low for some more advanced usages of this technique. In our work, we describe the attempt to use smartphone-based iPPG technique aimed to measure the tiny mismatch in RR interval data series recorded from left and right arms. We use the transmission mode iPPG, in which the light transmitted through the medium of finger is detected by a web-camera opposite the LED source. The computational scheme by processing and analysis of the received signal was implemented using MATLAB language (MathWork Inc. in the United States). We believe that further development of our approach may lead to fast and low cost method to access the state of the sympathetic nervous system.

  9. Fluorescence detection of small gastrointestinal tumours: principles, technique, first clinical experience.

    PubMed

    Orth, K; Russ, D; Steiner, R; Beger, H G

    2000-11-01

    Photodynamic therapy (PDT) is a form of cancer treatment based on the selective accumulation of a photosensitizer in neoplastic tissue. The fluorescent properties of a photosensitizer permit diagnostic localization of primary tumours and/or metastasis. Occult lesions are hard to detect and can easily be missed during routine laparoscopy. Fluorescence observation offers additional optical information and the ability to detect these occult tumours. Clinically, we used 5-aminolevulinic acid for peritoneal staining and tumour demarcation via tumour-specific fluorescence induced by protoporphyrin IX. For laparoscopic observations, a "D-Light" system was used; the conventional white light source was equipped with an optical blocking filter that transmits at the excitation wavelength (380-450 nm) and blocks all other parts of the spectrum. With the aid of a suitable observation filter, the relevant fluorescence was detectable. With the help of this fluorescence we increased the capacity to detect occult tumours, that were missed with white-light observation (9/26). In the gastrointestinal tract, we used a krypton laser at 405 nm for PP IX fluorescence induction. Although there were high sensitivity rates for neoplasms (81% peritoneal carcinomas, 60% gastric cancer), no exact histopathological statement could be achieved at because of false-positive fluorescence, mainly caused by inflammation (6/32). Current clinical goals and the future perspectives of photodynamic diagnostic are discussed.

  10. Development of a Rayleigh Scattering Diagnostic for Time-Resolved Gas Flow Velocity, Temperature, and Density Measurements in Aerodynamic Test Facilities

    NASA Technical Reports Server (NTRS)

    Mielke, Amy F.; Elam, Kristie A.; Sung, Chih-Jen

    2007-01-01

    A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded turbulent flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultiplier tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. An acoustically driven nozzle flow is studied to validate velocity fluctuation measurements, and an asymmetric oscillating counterflow with unequal enthalpies is studied to validate the measurement of temperature fluctuations. Velocity fluctuations are compared with constant temperature anemometry measurements and temperature fluctuations are compared with constant current anemometry measurements at the same locations. Time-series and power spectra of the temperature and velocity measurements are presented. A numerical simulation of the light scattering and detection process was developed and compared with experimental data for future use as an experiment design tool.

  11. Nanowire-based detector

    DOEpatents

    Berggren, Karl K; Hu, Xiaolong; Masciarelli, Daniele

    2014-06-24

    Systems, articles, and methods are provided related to nanowire-based detectors, which can be used for light detection in, for example, single-photon detectors. In one aspect, a variety of detectors are provided, for example one including an electrically superconductive nanowire or nanowires constructed and arranged to interact with photons to produce a detectable signal. In another aspect, fabrication methods are provided, including techniques to precisely reproduce patterns in subsequently formed layers of material using a relatively small number of fabrication steps. By precisely reproducing patterns in multiple material layers, one can form electrically insulating materials and electrically conductive materials in shapes such that incoming photons are redirected toward a nearby electrically superconductive materials (e.g., electrically superconductive nanowire(s)). For example, one or more resonance structures (e.g., comprising an electrically insulating material), which can trap electromagnetic radiation within its boundaries, can be positioned proximate the nanowire(s). The resonance structure can include, at its boundaries, electrically conductive material positioned proximate the electrically superconductive nanowire such that light that would otherwise be transmitted through the sensor is redirected toward the nanowire(s) and detected. In addition, electrically conductive material can be positioned proximate the electrically superconductive nanowire (e.g. at the aperture of the resonant structure), such that light is directed by scattering from this structure into the nanowire.

  12. Highly Efficient, All-Dielectric Huygens Metasurfaces

    NASA Astrophysics Data System (ADS)

    Ollanik, Adam; Farrar-Foley, Nick; Smith, Jake; Escarra, Matthew

    Demonstration of the control of light by the introduction of abrupt phase discontinuities across a subwavelength scale has opened the doors to a new level of wavefront control. All-dielectric Huygens metasurfaces hold significant promise due to their dramatically improved efficiency over plasmonic approaches. We present the successful design, computational modeling, and experimental realization of all-dielectric transmissive Huygens metasurfaces capable of deflection efficiency >90%. Dielectric Huygens sources, taking advantage of spectrally aligned electric and magnetic dipole resonances, are capable of tunable phase delay for transmitted light with near unity efficiency of forward scattering. Using ellipsoidal cylinder nanoantennas, we are able to manipulate the phase response and engineer a metasurface with a spatially gradient phase profile. Through careful design and optimization we mitigate the effects of inter-antenna coupling. We have designed and modeled metasurfaces demonstrating anomalous refraction with very high efficiency (>80%) for wavelength bands from the UV to the near-IR. These surfaces were designed using three distinct nanoantenna materials, Si, TiO2, and GaP, to demonstrate the flexibility of the technique. Experimentally, Si nanoantennas are fabricated using a combination of electron beam lithography and ICP/RIE-etching. Metasurfaces are characterized using a goniospectrometer capable of mapping light intensity on a cylindrical shell surrounding the metasurface.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKinnon, Archibald D.; Thompson, Seth R.; Doroshchuk, Ruslan A.

    mart grid technologies are transforming the electric power grid into a grid with bi-directional flows of both power and information. Operating millions of new smart meters and smart appliances will significantly impact electric distribution systems resulting in greater efficiency. However, the scale of the grid and the new types of information transmitted will potentially introduce several security risks that cannot be addressed by traditional, centralized security techniques. We propose a new bio-inspired cyber security approach. Social insects, such as ants and bees, have developed complex-adaptive systems that emerge from the collective application of simple, light-weight behaviors. The Digital Ants frameworkmore » is a bio-inspired framework that uses mobile light-weight agents. Sensors within the framework use digital pheromones to communicate with each other and to alert each other of possible cyber security issues. All communication and coordination is both localized and decentralized thereby allowing the framework to scale across the large numbers of devices that will exist in the smart grid. Furthermore, the sensors are light-weight and therefore suitable for implementation on devices with limited computational resources. This paper will provide a brief overview of the Digital Ants framework and then present results from test bed-based demonstrations that show that Digital Ants can identify a cyber attack scenario against smart meter deployments.« less

  14. Design and verification of a cloud field optical simulator

    NASA Technical Reports Server (NTRS)

    Davis, J. M.; Cox, S. K.; Mckee, T. B.

    1982-01-01

    A concept and an apparatus designed to investigate the reflected and transmitted distributions of light from optically thick clouds is presented. The Cloud Field Optical Simulator (CFOS) is a laboratory device which utilizes an array of incandescent lamps as a source, simulated clouds made from cotton or styrofoam as targets, and an array of silicon photodiodes as detectors. The device allows virtually any source-target-detector geometry to be examined. Similitude between real clouds and their CFOS cotton or styrofoam counterparts is established by relying on a linear relationship between optical depth and the ratio of reflected to transmitted light for a semi-infinite layer. Comparisons of principal plane radiances observed by the CFOS with Monte Carlo computations for a water cloud at 0.7 microns show excellent agreement.

  15. Ultralong time response of magnetic fluid based on fiber-optic evanescent field.

    PubMed

    Du, Bobo; Yang, Dexing; Bai, Yang; Yuan, Yuan; Xu, Jian; Jiang, Yajun; Wang, Meirong

    2016-07-20

    The ultralong time (a few hours) response properties of magnetic fluid using etched optical fiber are visualized and investigated experimentally. The operating structure is made by injecting magnetic fluid into a capillary tube that contains etched single-mode fiber. An interesting extreme asymmetry is observed, in which the transmitted light intensity after the etched optical fiber cannot reach the final steady value when the external magnetic field is turned on (referred to as the falling process), while it can reach the stable state quickly once the magnetic field is turned off (referred to as the rising process). The relationship between the response times/loss rates of the transmitted light and the strength of the applied magnetic field is obtained. The physical mechanisms of two different processes are discussed qualitatively.

  16. Optical power-based interrogation of plasmonic tilted fiber Bragg grating biosensors

    NASA Astrophysics Data System (ADS)

    González-Vila, Á.; Lopez-Aldaba, A.; Kinet, D.; Mégret, P.; Lopez-Amo, M.; Caucheteur, C.

    2017-04-01

    Two interrogation techniques for plasmonic tilted fiber Bragg grating sensors are reported and experimentally tested. Typical interrogation methods are usually based on tracking the wavelength shift of the most sensitive cladding mode, but for biosensing applications, spectrometer-based methods can be replaced by more efficient solutions. The proposed techniques thus rely on the measurement of the induced changes in optical power. The first one consists of a properly polarized tunable laser source set to emit at the wavelength of the sensor most sensitive mode and an optical power meter to measure the transmitted response. For the second method, a uniform fiber Bragg grating is photo-inscribed beyond the sensor in such a way that its central wavelength matches the sensor most sensitive mode, acting as an optical filter. Using a LED source, light reflected backwards by this grating is partially attenuated when passing through the sensor due to plasmon wave excitation and the power changes are quantified once again with an optical power meter. A performance analysis of the techniques is carried out and they both result competitive interrogation solutions. The work thus focuses on the development of cost-effective alternatives for monitoring this kind of biosensors in practical situations.

  17. Differential Radiometers Using Fabry-Perot Interferometric Technique for Remote Sensing of Greenhouse Gases

    NASA Technical Reports Server (NTRS)

    Georgieva, Elena M.; Heaps,William S.; Wilson, Emily L.

    2007-01-01

    A new type of remote sensing radiometer based upon the Fabry-Perot interferometric technique has been developed at NASA's Goddard Space Flight Center and tested from both ground and aircraft platform. The sensor uses direct or reflected sunlight and has channels for measuring column concentration of carbon dioxide at 1570 nm, oxygen lines sensitive to pressure and temperature at 762 and 768 nm, and water vapor (940 nm). A solid Fabry-Perot etalon is used as a tunable narrow bandpass filter to restrict the measurement to the gas of interest's absorption bands. By adjusting the temperature of the etalon, which changes the index of refraction of its material, the transmission fringes can be brought into nearly exact correspondence with absorption lines of the particular species. With this alignment between absorption lines and fringes, changes in the amount of a species in the atmosphere strongly affect the amount of light transmitted by the etalon and can be related to gas concentration. The technique is applicable to different chemical species. We have performed simulations and instrument design studies for CH4, "Cot isotope, and CO detection. Index Terms- Absorbing media, Atmospheric measurements, Fabry-Perot interferometers, Optical interferometry, Remote sensing.

  18. 47 CFR 80.213 - Modulation requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the 2900-3100 MHz band. Racons using frequency agile transmitting techniques must include circuitry... using frequency agile techniques must include circuitry designed to reduce interference caused by...

  19. 47 CFR 80.213 - Modulation requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the 2900-3100 MHz band. Racons using frequency agile transmitting techniques must include circuitry... using frequency agile techniques must include circuitry designed to reduce interference caused by...

  20. Bimorphic polymeric photomechanical actuator

    NASA Technical Reports Server (NTRS)

    Sarkisov, Sergey S. (Inventor); Curley, Michael J. (Inventor); Adamovsky, Grigory (Inventor); Sarkisov, Jr., Sergey S. (Inventor); Fields, Aisha B. (Inventor)

    2006-01-01

    A bimorphic polymeric photomechanical actuator, in one embodiment using polyvinylidene fluoride (PVDF) as a photosensitive body, transmitting light over fiber optic cables, and controlling the shape and pulse duration of the light pulse to control movement of the actuator. Multiple light beams are utilized to generate different ranges of motion for the actuator from a single photomechanical body and alternative designs use multiple light beams and multiple photomechanical bodies to provide controlled movement. Actuator movement using one or more ranges of motion is utilized to control motion to position an actuating element in three dimensional space.

  1. Optical design of tunnel lighting with white light-emitting diodes.

    PubMed

    Tsai, Ming-Shiou; Lee, Xuan-Hao; Lo, Yi-Chien; Sun, Ching-Cherng

    2014-10-10

    This paper presents a tunnel lighting design consisting of a cluster light-emitting diode and a free-form lens. Most of the energy emitted from the proposed luminaire is transmitted onto the surface of the road in front of drivers, and the probability that that energy is emitted directly into drivers' eyes is low. Compared with traditional fluorescent lamps, the proposed luminaire, of which the optical utilization factor, optical efficiency, and uniformity are, respectively, 44%, 92.5%, and 0.72, exhibits favorable performance in energy saving, glare reduction, and traffic safety.

  2. Space and time resolved representation of a vacuum arc light emission

    NASA Astrophysics Data System (ADS)

    Georgescu, N.; Sandolache, G.; Zoita, V.

    1999-04-01

    An optoelectronic multichannel detection system for the study of the visible light emission of a vacuum circuit breaker arc is described. The system consists of two multiple slit collimator assemblies coupled directly to the arc discharge chamber and an electronic detection part. The light emitted by the arc is collected by the two collimator assemblies and is transmitted through optical fibres to the electronic detection part. By using a new, simple computational method two-dimensional plots of the vacuum arc light emission at different times are obtained.

  3. Home Healthcare Program for Soil-Transmitted Helminthiasis in Schoolchildren along the Mekong River Basin.

    PubMed

    Kaewpitoon, Soraya J; Loyd, Ryan A; Kaewpitoon, Natthawut

    2015-05-01

    Soil-transmitted helminths (STH) are among the most important groups of infectious agents responsible for physical and intellectual growth retardation in children worldwide. Current status is need requiredfor the development of control programs. To determine the STH infections among the schoolchildren in the Mekong River basin near rural Ubon Ratchathani, Thailand and Champassak, Laos PDR, including their caregiver knowledge and attitude concerning prevention of STH infections. A cross sectional survey was designed as a home healthcare programfrom October 2009 to April 2012. 1,957 fecal samples were collected from children aged 5-12 years in five districts of Ubon Ratchathani province (1,012 fecal samples; Khong Chiam, Si Mueang Mai, Phibun Mangsahan, Sirindhorn, and Pho Sai), Thailand, and one district of Champassak Province (945 fecal samples; Pakse), Lao PDR. Fecal samples were prepared by the modified formalin ethylacetate concentration technique, and determined by light microscope. The knowledge and attitude of children's caregivers concerning prevention of soil-transmitted helminth infections were completed interviewed by semi-structured questionnaires. The overall intestinal helminth prevalence rate was 11.88%. Classified by species the STHs were as follows: Ascaris lumbricoides (30.9%), Trichuris trichiura (21.7%), and hookworm (20.5%). The highest prevalence was recorded in children aged 9 years and above. The highest prevalence of STH infection was found in the Pakse district of Laos PDR (16.08%). The intensities of infection with A. lumbricoides, T trichiura, and Hookworm were 1.82 ± 0.36, 1.32 ± 0.30, and 1.29 ± 0.32, respectively. 1,077 of caregivers were completed interviewed and found that the caregivers had fair levels of knowledge and attitude regarding soil-transmitted helminthiasis. These results suggest that priority should be given to STH eradication, the development of control programs in the Mekong River Basin, and the provision of education about STH to caregivers to reduce the risk of STH infection in their schoolchildren.

  4. Schistosomes infection rate in relation to environmental factors in school children.

    PubMed

    Raja'a, Y A; Assiragi, H M; Abu-Luhom, A A; Mohammed, A B; Albahr, M H; Ashaddadi, M A; Al Muflihi, A N

    2000-07-01

    An epidemiological comparative survey aimed at determination of prevalence and focal distribution of Schistosomes infection and intestinal parasites to provide a reference for evaluating the need for community intervention. All children of 14th October Primary School were involved. The children were from 7 villages that lie on the Assahul valley of lbb governorates in Yemen. The total number was 230 with (82%) boys and (18%) girls. Their age was between 5-18 years with a mean of 10.24 +/- 2.6 years. Millipore and modified Kato techniques were adopted to quantify urinary and intestinal Schistosomes eggs. Other ova, larvae, cysts were recorded whenever seen. It was revealed that there was a Schistosomes infection rate of 37%. The mansoni prevalence was 35%, hematobia was 5% and mixed infections were 3%. Light infection was classified among 17% of all children; moderate infection among 18% and no intense mansoni infection was determined. Whereas in the case of hematobia species, 2% were intense and 3% were light. Intensity in all children was 5% eggs/g feces in case of intestinal bilharzia and 1% egg/10 ml urine in case of urinary. With regard to the prevalence of any soil-transmitted parasites, it was found to be 69% (Ascariosis 68%, Trichuriosis 10%). Double infection was found in 10%. Hookworm eggs were not seen. Infection rates with other parasites were as follows: Giardiosis 18%, Amoebiosis 14%, ova of Hymenolepes nana were seen in 13%, Taeniosis affected 13% and E. Vermicularis 1%. Bivariate analysis revealed significant associations between Schistosomes infection with residence near the valley, male sex and frequent water contact activities. No significant association was found with the age of the child, parents' education, availability of latrine or household standpipe water. In conclusion, schistosomosis was moderate, whereas soil transmitted helminthosis were intense.

  5. Production of plasmas by long-wavelength lasers

    DOEpatents

    Dawson, J.M.

    1973-10-01

    A long-wavelength laser system for heating low-density plasma to high temperatures is described. In one embodiment, means are provided for repeatedly receiving and transmitting long-wavelength laser light in successive stages to form a laser-light beam path that repeatedly intersects with the equilibrium axis of a magnetically confined toroidal plasma column for interacting the laser light with the plasma for providing controlled thermonuclear fusion. Embodiments for heating specific linear plasmas are also provided. (Official Gazette)

  6. Controllable spectrum artificial sunlight source system using LEDs with 32 different peak wavelengths of 385-910 nm.

    PubMed

    Fujiwara, Kazuhiro; Yano, Akira

    2011-04-01

    This study developed a lighting system that produces an approximate spectral irradiance (SI) of ground level sunlight in the wavelength range of 385-910 nm (GLS₃₈₅₋₉₁₀) using 547 light-emitting diodes (LEDs) with 32 different peak wavelengths. The produced SI can be modified over an arbitrary wavelength band. The SI at the light outlet reached up to 1/2 of the GLS₃₈₅₋₉₁₀ of a sunny April day, although the produced SI deviated from the GLS₃₈₅₋₉₁₀ at some wavelengths. For subsequent experiments, the reference SI was defined as 1/4 GLS₃₈₅₋₉₁₀ of a sunny April day. The SI produced from the lighting system was adjusted to approximate the reference SI. The ratios of the produced SI and the reference SI were within 0.72-1.28. As an application of the lighting system for biological studies, the transmitted SI of a green leaf of perilla (Perilla frutescens L.) was investigated. The curve shape of the transmitted SI, which had characteristically low transmission percentages of blue and red light, reflected the characteristics of the absorption spectra of chlorophylls. The lighting system is therefore potentially beneficial for use in diagnosing physiological conditions of plant leaves, although its application is not limited to plant physiological studies. Copyright © 2010 Wiley-Liss, Inc.

  7. Photogrammetric point cloud compression for tactical networks

    NASA Astrophysics Data System (ADS)

    Madison, Andrew C.; Massaro, Richard D.; Wayant, Clayton D.; Anderson, John E.; Smith, Clint B.

    2017-05-01

    We report progress toward the development of a compression schema suitable for use in the Army's Common Operating Environment (COE) tactical network. The COE facilitates the dissemination of information across all Warfighter echelons through the establishment of data standards and networking methods that coordinate the readout and control of a multitude of sensors in a common operating environment. When integrated with a robust geospatial mapping functionality, the COE enables force tracking, remote surveillance, and heightened situational awareness to Soldiers at the tactical level. Our work establishes a point cloud compression algorithm through image-based deconstruction and photogrammetric reconstruction of three-dimensional (3D) data that is suitable for dissimination within the COE. An open source visualization toolkit was used to deconstruct 3D point cloud models based on ground mobile light detection and ranging (LiDAR) into a series of images and associated metadata that can be easily transmitted on a tactical network. Stereo photogrammetric reconstruction is then conducted on the received image stream to reveal the transmitted 3D model. The reported method boasts nominal compression ratios typically on the order of 250 while retaining tactical information and accurate georegistration. Our work advances the scope of persistent intelligence, surveillance, and reconnaissance through the development of 3D visualization and data compression techniques relevant to the tactical operations environment.

  8. Photophysics of C60 Colloids

    DTIC Science & Technology

    2012-11-28

    boiling of the liquid or vaporization of the particle). Light scatters out of the propagation path. • Enhanced absorption from nanoplasmas . 8 I...and thus, nanoplasmas that absorb and scatter the light • NLO behavior is fluence dependent • Uncalibrated measurements of transmitted, absorbed...after the first 1-2 ns • Proposed mechanism: Initial scattering by nanoplasmas followed by additional scattering from bubble growth in the

  9. Use of a fiberscope for examining cavity nests

    Treesearch

    Kathryn L. Purcell

    1997-01-01

    A system is described that uses a fiberscope to view nests in cavities to provide detailed information on eggs and nestlings. The flexible probe can be inserted around bends, and the tip articulates to allow viewing of the entire cavity and nest. A light guide bundle furnishes light to enable viewing of dark cavities and optical fibers transmit the impage from the lens...

  10. TV audio and video on the same channel

    NASA Technical Reports Server (NTRS)

    Hopkins, J. B.

    1979-01-01

    Transmitting technique adds audio to video signal during vertical blanking interval. SIVI (signal in the vertical interval) is used by TV networks and stations to transmit cuing and automatic-switching tone signals to augment automatic and manual operations. It can also be used to transmit one-way instructional information, such as bulletin alerts, program changes, and commercial-cutaway aural cues from the networks to affiliates. Additonally, it can be used as extra sound channel for second-language transmission to biligual stations.

  11. An elementary research on wireless transmission of holographic 3D moving pictures

    NASA Astrophysics Data System (ADS)

    Takano, Kunihiko; Sato, Koki; Endo, Takaya; Asano, Hiroaki; Fukuzawa, Atsuo; Asai, Kikuo

    2009-05-01

    In this paper, a transmitting process of a sequence of holograms describing 3D moving objects over the communicating wireless-network system is presented. A sequence of holograms involves holograms is transformed into a bit stream data, and then it is transmitted over the wireless LAN and Bluetooth. It is shown that applying this technique, holographic data of 3D moving object is transmitted in high quality and a relatively good reconstruction of holographic images is performed.

  12. Women and sexually transmitted diseases.

    PubMed

    Leonardo, C; Chrisler, J C

    1992-01-01

    This paper presents a brief review of historical developments in women's health care. It describes the current campaign against sexually transmitted diseases (STDs) and assesses the campaign's success in light of its history and the reality of women's lives. The authors suggest that women are forced into a double-bind in which they are expected to take responsibility for the prevention of STDs although they may not have the ability to do so. Modifications are suggested which take into account gender-role socialization and social group norms.

  13. Design of a K-Band Transmit Phased Array For Low Earth Orbit Satellite Communications

    NASA Technical Reports Server (NTRS)

    Watson, Thomas; Miller, Stephen; Kershner, Dennis; Anzic, Godfrey

    2000-01-01

    The design of a light weight, low cost phased array antenna is presented. Multilayer printed wiring board (PWB) technology is utilized for Radio Frequencies (RF) and DC/Logic manifold distribution. Transmit modules are soldered on one side and patch antenna elements are on the other, allowing the use of automated assembly processes. The 19 GHz antenna has two independently steerable beams, each capable of transferring data at 622 Mbps. A passive, self-contained phase change thermal management system is also presented.

  14. Optical signal processing for a smart vehicle lighting system using a-SiCH technology

    NASA Astrophysics Data System (ADS)

    Vieira, M. A.; Vieira, M.; Vieira, P.; Louro, P.

    2017-05-01

    We propose the use of Visible Light Communication (VLC) for vehicle safety applications, creating a smart vehicle lighting system that combines the functions of illumination and signaling, communications, and positioning. The feasibility of VLC is demonstrated by employing trichromatic Red-Green-Blue (RGB) LEDs as transmitters, since they offer the possibility of Wavelength Division Multiplexing (WDM), which can greatly increase the transmission data rate, when using SiC double p-i-n receivers to encode/decode the information. Trichromatic RGB Light Emitting Diodes (LED)s (RGB-LED) are used together for illumination proposes (headlamps) and individually, each chip, to transmit the driving range distance and data information. An on-off code is used to transmit the data. Free space is the transmission medium. The receivers consist of two stacked amorphous a-H:SiC cells. They combine the simultaneous demultiplexing operation with the photodetection and self-amplification. The proposed coding is based on SiC technology. Multiple Input Multi Output (MIMO) architecture is used. For data transmission, we propose the use of two headlights based on commercially available modulated white RGB-LEDs. For data receiving and decoding we use three a-SiC:H double pin/pin optical processors symmetrically distributed at the vehicle tail Moreover, we present a way to achieve vehicular communication using the parity bits. A representation with a 4 bit original string color message and the transmitted 7 bit string, the encoding and decoding accurate positional information processes and the design of SiC navigation system are discussed and tested. A visible multilateration method estimates the drive distance range by using the decoded information received from several non-collinear transmitters.

  15. Prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School, Jimma, Southwest Ethiopia.

    PubMed

    Tefera, Ephrem; Belay, Tariku; Mekonnen, Seleshi Kebede; Zeynudin, Ahmed; Belachew, Tefera

    2017-01-01

    Soil transmitted helminths are wide spread in developing countries and in Ethiopia the prevalence of STHs varies in different parts of the country. The aim of this study was to determine the prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School Jimma town, Southwestern Ethiopia. A cross-sectional study was conducted between March 29 and April 9, 2010 to determine the prevalence and intensity of soil transmitted helminths among elementary school children. The study participants were randomly selected from class enrollment list after proportional allocation of the total sample size to each grade. Data about the background characteristics were collected using structured questionnaire. The stool samples were examined by McMaster method for the egg count which was used to determine intensity of infection. Data were analyzed using SPSS for windows version 16 and p-value less than 5% was considered as statistically significant. Of the total 715 stool specimens examined, 346 were positive for at least one intestinal parasite making the prevalence 48.4%. The most prevalent parasites were Ascaris lumbricoides 169 (23.6%) and Trichuris trichiura 165 (23.1%). The prevalence of soil transmitted helminth in this study was 45.6% (326/715). There was statistically significant difference in the prevalence of Trichuriasis between those who use latrine always and who use sometimes (p = 0.010). Females are two times more likely to be positive for Ascaris than males (p = 0.039). Majority of the students had light infection of soil transmitted helminths and none of them had heavy intensity of infection of Trichuriasis and hookworms. Nearly half of the school children were infected with at least one STHs and majority of the students had light infection of soil transmitted helminths. Students who did not wash their hands after defecation were three times more likely to be positive for Ascaris infection than those who washed their hands after defecation. Therefore, measures like health information dissemination on the advantage of washing hands after defecation and on proper use of latrine should be taken into account to alleviate the problem.

  16. Prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School, Jimma, Southwest Ethiopia

    PubMed Central

    Tefera, Ephrem; Belay, Tariku; Mekonnen, Seleshi Kebede; Zeynudin, Ahmed; Belachew, Tefera

    2017-01-01

    Introduction Soil transmitted helminths are wide spread in developing countries and in Ethiopia the prevalence of STHs varies in different parts of the country. The aim of this study was to determine the prevalence and intensity of soil transmitted helminths among school children of Mendera Elementary School Jimma town, Southwestern Ethiopia. Methods A cross-sectional study was conducted between March 29 and April 9, 2010 to determine the prevalence and intensity of soil transmitted helminths among elementary school children. The study participants were randomly selected from class enrollment list after proportional allocation of the total sample size to each grade. Data about the background characteristics were collected using structured questionnaire. The stool samples were examined by McMaster method for the egg count which was used to determine intensity of infection. Data were analyzed using SPSS for windows version 16 and p-value less than 5% was considered as statistically significant. Results Of the total 715 stool specimens examined, 346 were positive for at least one intestinal parasite making the prevalence 48.4%. The most prevalent parasites were Ascaris lumbricoides 169 (23.6%) and Trichuris trichiura 165 (23.1%). The prevalence of soil transmitted helminth in this study was 45.6% (326/715). There was statistically significant difference in the prevalence of Trichuriasis between those who use latrine always and who use sometimes (p = 0.010). Females are two times more likely to be positive for Ascaris than males (p = 0.039). Majority of the students had light infection of soil transmitted helminths and none of them had heavy intensity of infection of Trichuriasis and hookworms. Conclusion Nearly half of the school children were infected with at least one STHs and majority of the students had light infection of soil transmitted helminths. Students who did not wash their hands after defecation were three times more likely to be positive for Ascaris infection than those who washed their hands after defecation. Therefore, measures like health information dissemination on the advantage of washing hands after defecation and on proper use of latrine should be taken into account to alleviate the problem. PMID:28819509

  17. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers.

    PubMed

    Schoenfeld, Andreas A; Poppinga, Daniela; Harder, Dietrich; Doerner, Karl-Joachim; Poppe, Bjoern

    2014-07-07

    Optical experiments and theoretical considerations have been undertaken in order to understand the causes of the 'orientation effect' and the 'parabola effect', the artefacts impairing the desired light absorption measurement on radiochromic EBT3 films with flatbed scanners. EBT3 films exposed to doses up to 20.9 Gy were scanned with an Epson Expression 10000XL flatbed scanner in landscape and portrait orientation. The horizontally and vertically polarized light components of the scanner were determined, and another Epson Expression 10000XL flatbed scanner was disassembled to examine its optical components. The optical properties of exposed and unexposed EBT3 films were studied with incident polarized and unpolarized white light, and the transmitted red light was investigated for its polarization and scattering properties including the distribution of the scattering angles. Neutral density filters were studied for comparison. Guidance was sought from the theory of light scattering from rod-like macromolecular structures. The drastic dose-dependent variation of the transmitted total light current as function of the orientation of front and rear polarizers, interpreted by light scattering theory, shows that the radiation-induced polymerization of the monomers of EBT3 films produces light scattering oscillators preferably polarized at right angles with the coating direction of the film. The directional distribution of the scattered light is partly anisotropic, with a preferred scattering plane at right angles with the coating direction, indicating light scattering from stacks of coherently vibrating oscillators piled up along the monomer crystals. The polyester carrier film also participates in these effects. The 'orientation' and 'parabola' artefacts due to flatbed scanning of radiochromic films can be explained by the interaction of the polarization-dependent and anisotropic light scattering from exposed and unexposed EBT3 films with the quantitative difference between the scanner's horizontally and vertically polarized light supply and with the limited directional acceptance of the scanner's light recording system.

  18. Radiation detection system

    DOEpatents

    Nelson, Melvin A.; Davies, Terence J.; Morton, III, John R.

    1976-01-01

    A radiation detection system which utilizes the generation of Cerenkov light in and the transmission of that light longitudinally through fiber optic wave guides in order to transmit intelligence relating to the radiation to a remote location. The wave guides are aligned with respect to charged particle radiation so that the Cerenkov light, which is generated at an angle to the radiation, is accepted by the fiber for transmission therethrough. The Cerenkov radiation is detected, recorded, and analyzed at the other end of the fiber.

  19. Absorption of a laser light pulse in a dense plasma.

    NASA Technical Reports Server (NTRS)

    Mehlman-Balloffet, G.

    1973-01-01

    An experimental study of the absorption of a laser light pulse in a transient, high-density, high-temperature plasma is presented. The plasma is generated around a metallic anode tip by a fast capacitive discharge occurring in vacuum. The amount of transmitted light is measured for plasmas made of different metallic ions in the regions of the discharge of high electronic density. Variation of the transmission during the laser pulse is also recorded. Plasma electrons are considered responsible for the very high absorption observed.

  20. Bidirectional scattering of light from tree leaves

    NASA Technical Reports Server (NTRS)

    Brakke, Thomas W.; Smith, James A.; Harnden, Joann M.

    1989-01-01

    A laboratory goniometer consisting of an He-Ne laser (632.8 nm), vertical leaf holder, and silicon photovoltaic detector was used to measure the bidirectional scattering (both transmittance and reflectance) of red oak and red maple. The illumination angles were 0, 30, and 60 deg, and the scattering was recorded approximately every 10 deg in the principal plane. The scattering profiles obtained show the non-Lambertian characteristics of the scattering, particularly for the off-nadir illumination directions. The transmitted light was more isotropic than the reflected light.

  1. Rayleigh rejection filters for 193-nm ArF laser Raman spectroscopy

    NASA Technical Reports Server (NTRS)

    Mckenzie, Robert L.

    1993-01-01

    Selected organic absorbers and their solvents are evaluated as spectral filters for the rejection of 193-nm Rayleigh light associated with the use of an ArF excimer laser for Raman spectroscopy. A simply constructed filter cell filled with 0.5 percent acetone in water and an optical path of 7 mm is shown effectively to eliminate stray Rayleigh light underlying the Raman spectrum from air while transmitting 60 percent of the Raman light scattered by O2.

  2. Semiconductor Laser with a Self-Pumped Phase Conjugate External Cavity

    DTIC Science & Technology

    1992-10-01

    laser light is considered planar. In actuality, the HLP 1400 laser diode used in this experiment has a gaussian profile. This approximation is frequently...return beam is in phase with either the light transmitted through or reflected off the rear facet of the diode laser. In Fig. 3.2, E, is the light ...In the first case an anti-reflection coated laser diode was used. It emitted a broadband spectrum without the feedback. The PCM just lowered the

  3. Quantitative phase-digital holographic microscopy: a new imaging modality to identify original cellular biomarkers of diseases

    NASA Astrophysics Data System (ADS)

    Marquet, P.; Rothenfusser, K.; Rappaz, B.; Depeursinge, C.; Jourdain, P.; Magistretti, P. J.

    2016-03-01

    Quantitative phase microscopy (QPM) has recently emerged as a powerful label-free technique in the field of living cell imaging allowing to non-invasively measure with a nanometric axial sensitivity cell structure and dynamics. Since the phase retardation of a light wave when transmitted through the observed cells, namely the quantitative phase signal (QPS), is sensitive to both cellular thickness and intracellular refractive index related to the cellular content, its accurate analysis allows to derive various cell parameters and monitor specific cell processes, which are very likely to identify new cell biomarkers. Specifically, quantitative phase-digital holographic microscopy (QP-DHM), thanks to its numerical flexibility facilitating parallelization and automation processes, represents an appealing imaging modality to both identify original cellular biomarkers of diseases as well to explore the underlying pathophysiological processes.

  4. Progress on a Rayleigh Scattering Mass Flux Measurement Technique

    NASA Technical Reports Server (NTRS)

    Mielke-Fagan, Amy F.; Clem, Michelle M.; Elam, Kristie A.; Hirt, Stefanie M.

    2010-01-01

    A Rayleigh scattering diagnostic has been developed to provide mass flux measurements in wind tunnel flows. Spectroscopic molecular Rayleigh scattering is an established flow diagnostic tool that has the ability to provide simultaneous density and velocity measurements in gaseous flows. Rayleigh scattered light from a focused 10 Watt continuous-wave laser beam is collected and fiber-optically transmitted to a solid Fabry-Perot etalon for spectral analysis. The circular interference pattern that contains the spectral information that is needed to determine the flow properties is imaged onto a CCD detector. Baseline measurements of density and velocity in the test section of the 15 cm x 15 cm Supersonic Wind Tunnel at NASA Glenn Research Center are presented as well as velocity measurements within a supersonic combustion ramjet engine isolator model installed in the tunnel test section.

  5. The cophylogeny of populations and cultures: reconstructing the evolution of Iranian tribal craft traditions using trees and jungles

    PubMed Central

    Tehrani, Jamshid J.; Collard, Mark; Shennan, Stephen J.

    2010-01-01

    Phylogenetic approaches to culture have shed new light on the role played by population dispersals in the spread and diversification of cultural traditions. However, the fact that cultural inheritance is based on separate mechanisms from genetic inheritance means that socially transmitted traditions have the potential to diverge from population histories. Here, we suggest that associations between these two systems can be reconstructed using techniques developed to study cospeciation between hosts and parasites and related problems in biology. Relationships among the latter are patterned by four main processes: co-divergence, intra-host speciation (duplication), intra-host extinction (sorting) and horizontal transfers. We show that patterns of cultural inheritance are structured by analogous processes, and then demonstrate the applicability of the host–parasite model to culture using empirical data on Iranian tribal populations. PMID:21041211

  6. Visible light metasurfaces based on gallium nitride high contrast gratings

    NASA Astrophysics Data System (ADS)

    Wang, Zhenhai; He, Shumin; Liu, Qifa; Wang, Wei

    2016-05-01

    We propose visible-light metasurfaces (VLMs) capable of serving as lens and beam deflecting element based on gallium nitride (GaN) high contrast gratings (HCGs). By precisely manipulating the wavefront of the transmitted light, we theoretically demonstrate an HCG focusing lens with transmissivity of 86.3%, and a VLM with beam deflection angle of 6.09° and transmissivity as high as 91.4%. The proposed all-dielectric metasurfaces are promising for GaN-based visible light-emitting diodes (LEDs), which would be robust and versatile for controlling the output light propagation and polarization, as well as enhancing the extraction efficiency of the LEDs.

  7. Photoelectrochemical cell

    DOEpatents

    Rauh, R. David; Boudreau, Robert A.

    1983-06-14

    A photoelectrochemical cell comprising a sealed container having a light-transmitting window for admitting light into the container across a light-admitting plane, an electrolyte in the container, a photoelectrode in the container having a light-absorbing surface arranged to receive light from the window and in contact with the electrolyte, the surface having a plurality of spaced portions oblique to the plane, each portion having dimensions at least an order of magnitude larger than the maximum wavelength of incident sunlight, the total surface area of the surface being larger than the area of the plane bounded by the container, and a counter electrode in the container in contact with the electrolyte.

  8. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2007-03-13

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  9. Daylight control system, device and method

    DOEpatents

    Paton, John Douglas

    2012-08-28

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  10. Daylight control system device and method

    DOEpatents

    Paton, John Douglas

    2009-12-01

    A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.

  11. Design and verification of a cloud field optical simulator

    NASA Technical Reports Server (NTRS)

    Davis, J. M.; Cox, S. K.; Mckee, T. B.

    1983-01-01

    A concept and an apparatus designed to investigate the reflected and transmitted distributions of light from optically thick clouds is presented. The Cloud Field Optical Simulator (CFOS) is a laboratory device which utilizes an array of incandescent lamps as a source, simulated clouds made from cotton or styrofoam as targets, and an array of silicon photodiodes as detectors. The device allows virtually any source-target-detector geometry to be examined. Similitude between real clouds and their CFOS cotton or styrofoam counterparts is established by relying on a linear relationship between optical depth and the ratio of reflected to transmitted light for a semiinfinite layer. Comparisons of principal plane radiances observed by the CFOS with Monte Carlo computations for a water cloud at 0.7 micron show excellent agreement. Initial applications of the CFOS are discussed.

  12. Novel high-performance scattering materials for use in energy-saving light fittings and skylights based on polymer pigmented with polymer

    NASA Astrophysics Data System (ADS)

    Smith, Geoffrey B.; Earp, Alan; Franklin, Jim B.; McCredie, Geoffrey

    2001-11-01

    Simple quantitative performance criteria are developed for translucent materials in terms of hemispherical visible transmittance, and angular spread of transmitted luminance using a half angle. Criteria are linked to applications in luminaires and skylights with emphasis on maximising visible throughput while minimising glare. These basic criteria are also extended to angle of incidence changes which are substantial. Example data is provided showing that acrylic pigmented with spherical polymer particles can have total hemispherical transmittance with weak thickness dependence, which is better than clear sheet, while the spread of transmitted light is quite thickness-sensitive and occurs over wider angles than inorganic pigments. This combination means significantly fewer lamps can achieve specified lux levels with low glare, and smaller skylights can provide higher, more uniform daylight illuminance.

  13. High temperature fiber optic microphone having a pressure-sensing reflective membrane under tensile stress

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Cuomo, Frank W. (Inventor); Robbins, William E. (Inventor); Hopson, Purnell, Jr. (Inventor)

    1992-01-01

    A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a backplate for damping membrane motion. The backplate further provides a means for on-line calibration of the microphone.

  14. Fiber optic microphone having a pressure sensing reflective membrane and a voltage source for calibration purpose

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Cuomo, Frank W. (Inventor); Robbins, William E. (Inventor)

    1993-01-01

    A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.

  15. Development of optical components for METIS instrument

    NASA Astrophysics Data System (ADS)

    Nardello, M.; Zuccon, S.; Corso, A. J.; Zuppella, P.; Naletto, G.; Fineschi, S.; Antonucci, E.; Pelizzo, M. G.

    2014-09-01

    The ESA mission Solar Orbiter (SOLO) is dedicated to the study of Solar Atmosphere and Heliosphere. As a part of the payload, the instrument METIS (Multi Element Telescope for Imaging and Spectroscopy) will provide images of the corona, both in the visible range and at the hydrogen Lyman-α emission line (121.6 nm). The realization of optical coatings, based on Al and MgF2, able to reflect/transmit such spectral component is therefore necessary. Since optical characteristics of materials in the VUV range are not well studied and greatly varying with realization process, we implemented a study of their properties in different deposition conditions. This is aimed to the realization of a custom designed filter, able to transmit the 121.6 nm while reflecting the visible light, and thus separate visible from UV light paths in the METIS instrument.

  16. Plasma arc welding weld imaging

    NASA Technical Reports Server (NTRS)

    Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)

    1994-01-01

    A welding torch for plasma arc welding apparatus has a transparent shield cup disposed about the constricting nozzle, the cup including a small outwardly extending polished lip. A guide tube extends externally of the torch and has a free end adjacent to the lip. First and second optical fiber bundle assemblies are supported within the guide tube. Light from a strobe light is transmitted along one of the assemblies to the free end and through the lip onto the weld site. A lens is positioned in the guide tube adjacent to the second assembly and focuses images of the weld site onto the end of the fiber bundle of the second assembly and these images are transmitted along the second assembly to a video camera so that the weld site may be viewed continuously for monitoring the welding process.

  17. Demonstration of UV LED versatility when paired with molded UV transmitting glass optics to produce unique irradiance patterns

    NASA Astrophysics Data System (ADS)

    Jasenak, Brian

    2017-02-01

    Ultraviolet light-emitting diode (UV LED) adoption is accelerating; they are being used in new applications such as UV curing, germicidal irradiation, nondestructive testing, and forensic analysis. In many of these applications, it is critically important to produce a uniform light distribution and consistent surface irradiance. Flat panes of fused quartz, silica, or glass are commonly used to cover and protect UV LED arrays. However, they don't offer the advantages of an optical lens design. An investigation was conducted to determine the effect of a secondary glass optic on the uniformity of the light distribution and irradiance. Glass optics capable of transmitting UV-A, UV-B, and UV-C wavelengths can improve light distribution, uniformity, and intensity. In this work, two simulation studies were created to illustrate distinct irradiance patterns desirable for potential real world applications. The first study investigates the use of a multi-UV LED array and optic to create a uniform irradiance pattern on the flat two dimensional (2D) target surface. The uniformity was improved by designing both the LED array and molded optic to produce a homogenous pattern. The second study investigated the use of an LED light source and molded optic to improve the light uniformity on the inside of a canister. The case study illustrates the requirements for careful selection of LED based on light distribution and subsequent design of optics. The optic utilizes total internal reflection to create optimized light distribution. The combination of the LED and molded optic showed significant improvement in uniformity on the inner surface of the canister. The simulations illustrate how the application of optics can significantly improve UV light distribution which can be critical in applications such as UV curing and sterilization.

  18. OptoRadio: a method of wireless communication using orthogonal M-ary PSK (OMPSK) modulation

    NASA Astrophysics Data System (ADS)

    Gaire, Sunil Kumar; Faruque, Saleh; Ahamed, Md. Maruf

    2016-09-01

    Laser based radio communication system, i.e. OptoRadio, using Orthogonal M-ary PSK Modulation scheme is presented in this paper. In this scheme, when a block of data needs to be transmitted, the corresponding block of biorthogonal code is transmitted by means of multi-phase shift keying. At the receiver, two photo diodes are cross coupled. The effect is that the net output power due to ambient light is close to zero. The laser signal is then transmitted only into one of the receivers. With all other signals being cancelled out, the laser signal is an overwhelmingly dominant signal. The detailed design, bit error correction capabilities, and bandwidth efficiency are presented to illustrate the concept.

  19. Optical manifold

    DOEpatents

    Falicoff, Waqidi; Chaves, Julio C.; Minano, Juan Carlos; Benitez, Pablo; Dross, Oliver; Parkyn, Jr., William A.

    2010-02-23

    Optical systems are described that have at least one source of a beam of blue light with divergence under 15.degree.. A phosphor emits yellow light when excited by the blue light. A collimator is disposed with the phosphor and forms a yellow beam with divergence under 15.degree.. A dichroic filter is positioned to transmit the beam of blue light to the phosphor and to reflect the beam of yellow light to an exit aperture. In different embodiments, the beams of blue and yellow light are incident upon said filter with central angles of 15.degree., 22.degree., and 45.degree.. The filter may reflect all of one polarization and part of the other polarization, and a polarization rotating retroreflector may then be provided to return the unreflected light to the filter.

  20. Arduino-based experiment demonstrating Malus’s law

    NASA Astrophysics Data System (ADS)

    Freitas, W. P. S.; Cena, C. R.; Alves, D. C. B.; Goncalves, A. M. B.

    2018-05-01

    Malus’s law states that the intensity of light after passing through two polarizers is proportional to the square of the cosine of the angle between the polarizers. We present a simple setup demonstrating this law. The novelty of our work is that we use a multi-turn potentiometer mechanically linked to one of the polarizers to measure the polarizer’s rotation angle while keeping the other polarizer fixed. Both the potentiometer and light sensor used to measure the transmitted light intensity are connected to an Arduino board so that the intensity of light is measured as a function of the rotation angle.

  1. Retinal Effects Of Blue Light Exposure

    NASA Astrophysics Data System (ADS)

    Ham, William T.; Mueller, Harold A.; Ruffolo, J. J.

    1980-10-01

    Recent research has shown that blue light exposure is an important factor in certain types of retinal injury. The mammalian ocular media transmits the spectral band 400-1400 nm to the retina. The short wavelengths (400-550 nm) produce a photochemical or actinic type of damage, while the longer wavelengths (550-1400 nm) produce thermal damage. Distinction between the two types of retinal damage are discussed briefly and the importance of the blue light effect for solar retinitis and eclipse blindness is emphasized. The significance of blue light retinal injury is summarized for various environmental and occupational exposures.

  2. Double-heterojunction nanorod light-responsive LEDs for display applications.

    PubMed

    Oh, Nuri; Kim, Bong Hoon; Cho, Seong-Yong; Nam, Sooji; Rogers, Steven P; Jiang, Yiran; Flanagan, Joseph C; Zhai, You; Kim, Jae-Hwan; Lee, Jungyup; Yu, Yongjoon; Cho, Youn Kyoung; Hur, Gyum; Zhang, Jieqian; Trefonas, Peter; Rogers, John A; Shim, Moonsub

    2017-02-10

    Dual-functioning displays, which can simultaneously transmit and receive information and energy through visible light, would enable enhanced user interfaces and device-to-device interactivity. We demonstrate that double heterojunctions designed into colloidal semiconductor nanorods allow both efficient photocurrent generation through a photovoltaic response and electroluminescence within a single device. These dual-functioning, all-solution-processed double-heterojunction nanorod light-responsive light-emitting diodes open feasible routes to a variety of advanced applications, from touchless interactive screens to energy harvesting and scavenging displays and massively parallel display-to-display data communication. Copyright © 2017, American Association for the Advancement of Science.

  3. An Arduino-based experiment designed to clarify the transition to total internal reflection

    NASA Astrophysics Data System (ADS)

    Atkin, Keith

    2018-03-01

    The topic of refraction and reflection of light at the boundary of transparent media is a fundamentally important one. The special case of total internal reflection is however commonly misrepresented in elementary textbooks. This paper addresses the problem and describes an experimental procedure for measuring and displaying reflected and transmitted light intensities using readily available components and the Arduino microcontroller.

  4. Spectral filters for laser communications

    NASA Technical Reports Server (NTRS)

    Shaik, K.

    1991-01-01

    Optical communication systems must perform reliabily under strong background light interference. Since the transmitting lasers operate within a narrow spectral band, high signal to noise ratios can be achieved when narrowband spectral optical filters can be used to reject out of band light. Here, a set of general requirements for such filters are developed, and an overview is given of suitable spectral filter technologies for optical communication systems.

  5. Skylab

    NASA Image and Video Library

    1970-01-01

    This 1970 photograph shows the flight unit for Skylab's White Light Coronagraph, an Apollo Telescope Mount (ATM) facility that photographed the solar corona in the visible light spectrum. A TV camera in the instrument provided real-time pictures of the occulted Sun to the astronauts at the control console and also transmitted the images to the ground. The Marshall Space Flight Center had program management responsibility for the development of Skylab hardware and experiments.

  6. Color image display and visual perception in computer graphics

    NASA Astrophysics Data System (ADS)

    Bouatouch, Kadi; Tellier, Pierre

    1996-03-01

    This paper put an emphasis on the importance of two points which are crucial when the aim is physically based lighting simulation. The first one is the spectral approach which considers emitted, reflected, diffused and transmitted light as wavelength dependent. The second corresponds to the different steps aiming at converting into RGB components the radiance arriving at the viewpoint through the pixels of a screen.

  7. Quantum Polarization Spectroscopy of Ultracold Spinor Gases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eckert, K.; Zawitkowski, L.; Sanpera, A.

    2007-03-09

    We propose a method for the detection of ground state quantum phases of spinor gases through a series of two quantum nondemolition measurements performed by sending off-resonant, polarized light pulses through the gas. Signatures of various mean-field as well as strongly correlated phases of F=1 and F=2 spinor gases obtained by detecting quantum fluctuations and mean values of polarization of transmitted light are identified.

  8. Slow light in saturable absorbers: Progress in the resolution of a controversy

    NASA Astrophysics Data System (ADS)

    Macke, Bruno; Razdobreev, Igor; Ségard, Bernard

    2017-06-01

    There are two opposing models in the analysis of the slow transmission of light pulses through saturable absorbers. The canonical incoherent bleaching model simply explains the slow transmission by combined effects of saturation and of noninstantaneous response of the medium resulting in absorption of the front part of the incident pulse larger than that of its rear. The second model, referred to as the coherent-population-oscillations (CPO) model, considers light beams whose intensity is slightly pulse modulated and attributes the time delay of the transmitted pulse to a reduction of the group velocity. We point out some inconsistencies in the CPO model and show that the two models lie in reality on the same hypotheses, the equations derived in the duly rectified CPO model being local expressions of the integral equations obtained in the incoherent bleaching model. When intense pulses without background are used, the CPO model, based on linearized equations, breaks down. The incoherent bleaching model then predicts that the transmitted light should vanish when the intensity of the incident light is strictly zero. This point is confirmed by the experiments that we have performed on ruby with square-wave incident pulses and we show that the whole shape of the observed pulses agrees with that derived analytically by means of the incoherent bleaching model. We also determine in this model the corresponding evolution of the fluorescence light, which seems to have been evidenced in other experiments.

  9. Holographic microscopy for in situ studies of microorganism motility

    NASA Astrophysics Data System (ADS)

    Nadeau, J.; Hu, S.; Jericho, S.; Lindensmith, C.

    2011-12-01

    Robust technologies for the detection and identification of microorganisms at low concentrations in complex liquid media are needed for numerous applications: environmental and medical microbiology, food safety, and for the search for microbial life elsewhere in the Solar System. The best current method for microbial enumeration is specific labeling with fluorescent dyes followed by high-resolution light microscopy. However, fluorescent techniques are difficult to use in situ in extreme environments (such as the Arctic and Antarctic or the open ocean) due to the fragility of the instruments and their high power demands. In addition, light microscopic techniques rarely provide insight into microbial motility behaviors. Tracking single cells would provide important insight into the physics of micron-scale motility as well as into key microbial phenomena such as surface attachment and invasiveness. An alternative to traditional light microscopy that is attracting increasing attention is holographic microscopy. Holographic microscopy works by illuminating the object of interest with coherent light from a laser. The light reflected from (or transmitted through) the object is then combined with a coherent reference beam to create an interference pattern that contains the phase and intensity information required to reconstruct a three dimensional image of the object. The interference pattern is recorded on a high resolution detector and can be used to computationally reconstruct a 3D image of the object. The lateral resolution of the image depends upon the wavelength of the light used, the laser power, camera quality, and external noise sources (vibration, stray light, and so forth). Although the principle is simple, technological barriers have prevented wider use of holographic microscopy. Laser sources and CCD cameras with the appropriate properties have only very recently become affordable. In addition, holographic microscopy leads to large data sets that are computationally intensive to reconstruct images from, so the technology to store and process large amounts of data are required. We have successfully deployed a digital in-line holographic microscope in lakes of the Canadian High Arctic and the open ocean. We present characteristic data sets from these experiments, as well as discussing how data acquisition and instrumentation can be improved. A design for a new type of autonomous, submersible holographic microscope incorporating an off-axis reference beam is presented, and future plans for controlled microbe-polymer studies are detailed.

  10. Violet Light Exposure Can Be a Preventive Strategy Against Myopia Progression.

    PubMed

    Torii, Hidemasa; Kurihara, Toshihide; Seko, Yuko; Negishi, Kazuno; Ohnuma, Kazuhiko; Inaba, Takaaki; Kawashima, Motoko; Jiang, Xiaoyan; Kondo, Shinichiro; Miyauchi, Maki; Miwa, Yukihiro; Katada, Yusaku; Mori, Kiwako; Kato, Keiichi; Tsubota, Kinya; Goto, Hiroshi; Oda, Mayumi; Hatori, Megumi; Tsubota, Kazuo

    2017-02-01

    Prevalence of myopia is increasing worldwide. Outdoor activity is one of the most important environmental factors for myopia control. Here we show that violet light (VL, 360-400nm wavelength) suppresses myopia progression. First, we confirmed that VL suppressed the axial length (AL) elongation in the chick myopia model. Expression microarray analyses revealed that myopia suppressive gene EGR1 was upregulated by VL exposure. VL exposure induced significantly higher upregulation of EGR1 in chick chorioretinal tissues than blue light under the same conditions. Next, we conducted clinical research retrospectively to compare the AL elongation among myopic children who wore eyeglasses (VL blocked) and two types of contact lenses (partially VL blocked and VL transmitting). The data showed the VL transmitting contact lenses suppressed myopia progression most. These results suggest that VL is one of the important outdoor environmental factors for myopia control. Since VL is apt to be excluded from our modern society due to the excessive UV protection, VL exposure can be a preventive strategy against myopia progression. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Multiple-Path-Length Optical Absorbance Cell

    NASA Technical Reports Server (NTRS)

    2001-01-01

    An optical absorbance cell that offers a selection of multiple optical path lengths has been developed as part of a portable spectrometric instrument that measures absorption spectra of small samples of water and that costs less than does a conventional, non-portable laboratory spectrometer. The instrument is intended, more specifically, for use in studying colored dissolved organic matter (CDOM) in seawater, especially in coastal regions. Accurate characterization of CDOM is necessary for building bio-optical mathematical models of seawater. The multiple path lengths of the absorption cell afford a wide range of sensitivity needed for measuring the optical absorbances associated with the wide range of concentrations of CDOM observed in nature. The instrument operates in the wavelength range of 370 to 725 nm. The major subsystems of the instrument (see figure) include a color-balanced light source; the absorption cell; a peristaltic pump; a high-precision, low-noise fiber optic spectrometer; and a laptop or other personal computer. A fiber-optic cable transmits light from the source to the absorption cell. Other optical fibers transmit light from the absorption cell to the spectrometer,

  12. Design issues for semi-passive optical communication devices

    NASA Astrophysics Data System (ADS)

    Glaser, I.

    2007-09-01

    Optical smart cards are devices containing a retro-reflector, light modulator, and some computing and data storage capabilities to affect semi-passive communication. They do not produce light; instead they modulate and send back light received from a stationary unit. These devices can replace contact-based smart cards as well as RF based ones for applications ranging from identification to transmitting and validating data. Since their transmission is essentially focused on the receiving unit, they are harder to eavesdrop than RF devices, yet need no physical contact or alignment. In this paper we explore optical design issues of these devices and estimate their optical behavior. Specifically, we analyze how these compact devices can be optimized for selected application profiles. Some of the key parameters addressed are effective light efficiency (how much modulated signal can be received by the stationary unit given the amount of light it transmits), range of tilt angles (angle between device surface normal to the line connecting the optical smart card with the stationary unit) through which the device would be effective, and power requirements of the semi-passive unit. In addition, issues concerning compact packaging of this device are discussed. Finally, results of the analysis are employed to produce a comparison of achievable capabilities of these optical smart cards, as opposed to alternative devices, and discuss potential applications were they can be best utilized.

  13. Spectral transmission of the human crystalline lens in adult and elderly persons: color and total transmission of visible light.

    PubMed

    Artigas, Jose M; Felipe, Adelina; Navea, Amparo; Fandiño, Adriana; Artigas, Cristina

    2012-06-26

    To experimentally measure the spectral transmission of human crystalline lenses belonging to adult and elderly persons, and to determine the color and total transmission of visible light of such crystalline lenses. The spectral transmission curve of 32 human crystalline lenses was measured using a PerkinElmer 800UV/VIS spectrometer. Total transmission of visible light and the chromatic coordinates of these crystalline lenses were determined from these curves for solar illumination. The crystalline lens that filters UV and its transmission in the visible spectrum decreases with age; such a decrease is greater for short wavelengths. The total transmission of visible light decreases, especially after the age of 70 years, and the crystalline color becomes yellower and saturated. The great variability existing in the spectral transmission of the human crystalline lens is lesser between the ages of 40 and 59 years, but greater from the age of 60 and older. The decrement in transmittance between these two age groups varies from 40% for 420 nm to 18% for 580 nm. Nevertheless, it is proven that age is not the only parameter affecting crystalline transmission. In the range of 40 to 59 years, age does not bear an influence on total transmission of light, but from 60 years and older it does. Moreover, the light transmitted decreases with age. This total transmission of light is similar to or lower than the amount that the different intraocular lenses transmit, even with a yellow or orange filter. The color of the human lens becomes yellowish and saturated with age.

  14. Optical Analysis of Power Distribution in Top-Emitting Organic Light Emitting Diodes Integrated with Nanolens Array Using Finite Difference Time Domain.

    PubMed

    Han, Kyung-Hoon; Park, Young-Sam; Cho, Doo-Hee; Han, Yoonjay; Lee, Jonghee; Yu, Byounggon; Cho, Nam Sung; Lee, Jeong-Ik; Kim, Jang-Joo

    2018-06-06

    Recently, we have addressed that a formation mechanism of a nanolens array (NLA) fabricated by using a maskless vacuum deposition is explained as the increase in surface tension of organic molecules induced by their crystallization. Here, as another research using finite difference time domain simulations, not electric field intensities but transmitted energies of electromagnetic waves inside and outside top-emitting blue organic light-emitting diodes (TOLEDs), without and with NLAs, are obtained, to easily grasp the effect of NLA formation on the light extraction of TOLEDs. Interestingly, the calculations show that NLA acts as an efficient light extraction structure. With NLA, larger transmitted energies in the direction from emitting layer to air are observed, indicating that NLAs send more light to air otherwise trapped in the devices by reducing the losses by waveguide and absorption. This is more significant for higher refractive index of NLA. Simulation and measurement results are consistent. A successful increase in both light extraction efficiency and color stability of blue TOLEDs, rarely reported before, is accomplished by introducing the highly process-compatible NLA technology using the one-step dry process. Blue TOLEDs integrated with a N, N'-di(1-naphthyl)- N, N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine NLA with a refractive index of 1.8 show a 1.55-times-higher light extraction efficiency, compared to those without it. In addition, viewing angle characteristics are enhanced and image blurring is reduced, indicating that the manufacturer-adaptable technology satisfies the requirements of highly efficient and color-stable top-emission displays.

  15. Design of the scanning mode coated glass color difference online detection system

    NASA Astrophysics Data System (ADS)

    Bi, Weihong; Zhang, Yu; Wang, Dajiang; Zhang, Baojun; Fu, Guangwei

    2008-03-01

    A design of scanning mode coated glass color difference online detection system was introduced. The system consisted of color difference data acquirement part and orbit control part. The function of the color difference data acquirement part was to acquire glass spectral reflectance and then processed them to get the color difference value. Using fiber for light guiding, the reflected light from surface of glass was transmitted into light division part, and the dispersive light was imaged on linear CCD, and then the output signals from the CCD was sampled pixel by pixel, and the spectral reflectance of coated glass was obtained finally. Then, the acquired spectral reflectance signals was sent to industrial personal computer through USB interface, using standard color space and color difference formula nominated by International Commission on Illumination (CIE) in 1976 to process these signals, and the reflected color parameter and color difference of coated glass was gained in the end. The function of the orbit control part was to move the detection probe by way of transverse scanning mode above the glass strip, and control the measuring start-stop time of the color difference data acquirement part at the same time. The color difference data acquirement part of the system was put on the orbit which is after annealing area in coated glass production line, and the protected fiber probe was placed on slide of the orbit. Using single chip microcomputer to control transmission mechanism of the slide, which made the slide move by way of transverse scanning mode on the glass strip, meanwhile, the color difference data acquirement part of the system was also controlled by the single chip microcomputer, and it made the acquirement part measure color difference data when the probe reached the needed working speed and required place on the glass strip. The scanning mode coated glass color difference online detection system can measure color parameter and color difference of each transverse point on glass strip, it can also measure lengthways color stability on glass strip. Furthermore, the measuring results can be transmitted to coated control room through intranet, so it is very useful to improve producing technique in time. In addition, equipping necessary marking machine, this system can classify glass board automatically based on the measuring result.

  16. Analysis of the color rendition of flexible endoscopes

    NASA Astrophysics Data System (ADS)

    Murphy, Edward M.; Hegarty, Francis J.; McMahon, Barry P.; Boyle, Gerard

    2003-03-01

    Endoscopes are imaging devices routinely used for the diagnosis of disease within the human digestive tract. Light is transmitted into the body cavity via incoherent fibreoptic bundles and is controlled by a light feedback system. Fibreoptic endoscopes use coherent fibreoptic bundles to provide the clinician with an image. It is also possible to couple fibreoptic endoscopes to a clip-on video camera. Video endoscopes consist of a small CCD camera, which is inserted into gastrointestinal tract, and associated image processor to convert the signal to analogue RGB video signals. Images from both types of endoscope are displayed on standard video monitors. Diagnosis is dependent upon being able to determine changes in the structure and colour of tissues and biological fluids, and therefore is dependent upon the ability of the endoscope to reproduce the colour of these tissues and fluids with fidelity. This study investigates the colour reproduction of flexible optical and video endoscopes. Fibreoptic and video endoscopes alter image colour characteristics in different ways. The colour rendition of fibreoptic endoscopes was assessed by coupling them to a video camera and applying video colorimetric techniques. These techniques were then used on video endoscopes to assess how the colour rendition of video endoscopes compared with that of optical endoscopes. In both cases results were obtained at fixed illumination settings. Video endoscopes were then assessed with varying levels of illumination. Initial results show that at constant luminance endoscopy systems introduce non-linear shifts in colour. Techniques for examining how this colour shift varies with illumination intensity were developed and both methodology and results will be presented. We conclude that more rigorous quality assurance is required to reduce colour error and are developing calibration procedures applicable to medical endoscopes.

  17. Apparatus, Method, and Computer Program for a Resolution-Enhanced Pseudo-Noise Code Technique

    NASA Technical Reports Server (NTRS)

    Li, Steven X. (Inventor)

    2015-01-01

    An apparatus, method, and computer program for a resolution enhanced pseudo-noise coding technique for 3D imaging is provided. In one embodiment, a pattern generator may generate a plurality of unique patterns for a return to zero signal. A plurality of laser diodes may be configured such that each laser diode transmits the return to zero signal to an object. Each of the return to zero signal includes one unique pattern from the plurality of unique patterns to distinguish each of the transmitted return to zero signals from one another.

  18. Study on dynamic deformation synchronized measurement technology of double-layer liquid surfaces

    NASA Astrophysics Data System (ADS)

    Tang, Huiying; Dong, Huimin; Liu, Zhanwei

    2017-11-01

    Accurate measurement of the dynamic deformation of double-layer liquid surfaces plays an important role in many fields, such as fluid mechanics, biomechanics, petrochemical industry and aerospace engineering. It is difficult to measure dynamic deformation of double-layer liquid surfaces synchronously for traditional methods. In this paper, a novel and effective method for full-field static and dynamic deformation measurement of double-layer liquid surfaces has been developed, that is wavefront distortion of double-wavelength transmission light with geometric phase analysis (GPA) method. Double wavelength lattice patterns used here are produced by two techniques, one is by double wavelength laser, and the other is by liquid crystal display (LCD). The techniques combine the characteristics such as high transparency, low reflectivity and fluidity of liquid. Two color lattice patterns produced by laser and LCD were adjusted at a certain angle through the tested double-layer liquid surfaces simultaneously. On the basis of the refractive indexes difference of two transmitted lights, the double-layer liquid surfaces were decoupled with GPA method. Combined with the derived relationship between phase variation of transmission-lattice patterns and out-of plane heights of two surfaces, as well as considering the height curves of the liquid level, the double-layer liquid surfaces can be reconstructed successfully. Compared with the traditional measurement method, the developed method not only has the common advantages of the optical measurement methods, such as high-precision, full-field and non-contact, but also simple, low cost and easy to set up.

  19. [Correlation between soil-transmitted nematode infections and children's growth].

    PubMed

    Wang, Xiao-Bing; Wang, Guo-Fei; Zhang, Lin-Xiu; Luo, Ren-Fu; Wang, Ju-Jun; Medina, Alexis; Eggleston, Karen; Rozelle, Scott; Smith, Scott

    2013-06-01

    To understand the infection status of soil-transmitted nematodes in southwest China and the correlation between soil-transmitted nematode infections and children's growth. The prevalence of soil-transmitted nematode infections was determined by Kato-Katz technique, and in part of the children, the examination of Enterobius vermicularis eggs was performed by using the cellophane swab method. The influencing factors were surveyed by using a standardized questionnaire. The relationship between soil-transmitted nematode infections and children's growth was analyzed by the ordinary least square (OLS) method. A total of 1 707 children were examined, with a soil-transmitted nematode infection rate of 22.2%. The results of OLS analysis showed that there existed the negative correlation between soil-transmitted nematode infections and the indexes of children's growth including BMI, the weight-for-age Z score and height-for-age Z score. Furthermore, other correlated variables included the age, gender, educational level of mother and raising livestock and poultry, etc. Children' s retardation is still a serious issue in the southwest poor areas of China and correlated with the infections of soil-transmitted nematodes. For improving children's growth, it is greatly significant to enhance the deworming and health education about parasitic diseases in mothers.

  20. Natural light illumination system.

    PubMed

    Whang, Allen Jong-Woei; Chen, Yi-Yung; Yang, Shu-Hua; Pan, Po-Hsuan; Chou, Kao-Hsu; Lee, Yu-Chi; Lee, Zong-Yi; Chen, Chi-An; Chen, Cheng-Nan

    2010-12-10

    In recent years, green energy has undergone a lot of development and has been the subject of many applications. Many research studies have focused on illumination with sunlight as a means of saving energy and creating healthy lighting. Natural light illumination systems have collecting, transmitting, and lighting elements. Today, most daylight collectors use dynamic concentrators; these include Sun tracking systems. However, this design is too expensive to be cost effective. To create a low-cost collector that can be easily installed on a large building, we have designed a static concentrator, which is prismatic and cascadable, to collect sunlight for indoor illumination. The transmission component uses a large number of optical fibers. Because optical fibers are expensive, this means that most of the cost for the system will be related to transmission. In this paper, we also use a prismatic structure to design an optical coupler for coupling n to 1. With the n-to-1 coupler, the number of optical fibers necessary can be greatly reduced. Although this new natural light illumination system can effectively guide collected sunlight and send it to the basement or to other indoor places for healthy lighting, previously there has been no way to manage the collected sunlight when lighting was not desired. To solve this problem, we have designed an optical switch and a beam splitter to control and separate the transmitted light. When replacing traditional sources, the lighting should have similar characteristics, such as intensity distribution and geometric parameters, to those of traditional artificial sources. We have designed, simulated, and optimized an illumination lightpipe with a dot pattern to redistribute the collected sunlight from the natural light illumination system such that it equals the qualities of a traditional lighting system. We also provide an active lighting module that provides lighting from the natural light illumination system or LED auxiliary sources, depending on circumstances. The system is controlled by a light detector. We used optical simulation tools to design and simulate the efficiency of the active module. Finally, we used the natural light illumination system to provide natural illumination for a traffic tunnel. This system will provide a great number of benefits for the people who use it.

  1. Method for enhancing signals transmitted over optical fibers

    DOEpatents

    Ogle, James W.; Lyons, Peter B.

    1983-01-01

    A method for spectral equalization of high frequency spectrally broadband signals transmitted through an optical fiber. The broadband signal input is first dispersed by a grating. Narrow spectral components are collected into an array of equalizing fibers. The fibers serve as optical delay lines compensating for material dispersion of each spectral component during transmission. The relative lengths of the individual equalizing fibers are selected to compensate for such prior dispersion. The output of the equalizing fibers couple the spectrally equalized light onto a suitable detector for subsequent electronic processing of the enhanced broadband signal.

  2. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, Russell B.

    1987-01-01

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  3. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, R.B.

    1985-08-15

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  4. Capsule Design for Blue Light Therapy against Helicobacter pylori.

    PubMed

    Li, Zhangyong; Ren, Binbin; Tan, Haiyan; Liu, Shengrong; Wang, Wei; Pang, Yu; Lin, Jinzhao; Zeng, Chen

    2016-01-01

    A photo-medical capsule that emits blue light for Helicobacter pylori treatment was described in this paper. The system consists of modules for pH sensing and measuring, light-emitting diode driver circuit, radio communication and microcontroller, and power management. The system can differentiate locations by monitoring the pH values of the gastrointestinal tract, and turn on and off the blue light according to the preset range of pH values. Our experimental tests show that the capsule can operate in the effective light therapy mode for more than 32 minutes and the wireless communication module can reliably transmit the measured pH value to a receiver located outside the body.

  5. 30 CFR 75.1719-1 - Illumination in working places.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., hydraulic, pneumatic, or mechanical power supplied by a source located on the machine or transmitted to the machine by cables, ropes, or chains. (c) The lighting prescribed in this section shall be in addition to...

  6. 30 CFR 75.1719-1 - Illumination in working places.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., hydraulic, pneumatic, or mechanical power supplied by a source located on the machine or transmitted to the machine by cables, ropes, or chains. (c) The lighting prescribed in this section shall be in addition to...

  7. Automatic weld torch guidance control system

    NASA Technical Reports Server (NTRS)

    Smaith, H. E.; Wall, W. A.; Burns, M. R., Jr.

    1982-01-01

    A highly reliable, fully digital, closed circuit television optical, type automatic weld seam tracking control system was developed. This automatic tracking equipment is used to reduce weld tooling costs and increase overall automatic welding reliability. The system utilizes a charge injection device digital camera which as 60,512 inidividual pixels as the light sensing elements. Through conventional scanning means, each pixel in the focal plane is sequentially scanned, the light level signal digitized, and an 8-bit word transmitted to scratch pad memory. From memory, the microprocessor performs an analysis of the digital signal and computes the tracking error. Lastly, the corrective signal is transmitted to a cross seam actuator digital drive motor controller to complete the closed loop, feedback, tracking system. This weld seam tracking control system is capable of a tracking accuracy of + or - 0.2 mm, or better. As configured, the system is applicable to square butt, V-groove, and lap joint weldments.

  8. Analysis of particle in liquid using excitation-fluorescence spectral flow cytometer

    NASA Astrophysics Data System (ADS)

    Takenaka, Kei; Togashi, Shigenori

    2018-01-01

    We have developed a new flow cytometer that can measure the excitation-fluorescence spectra of a single particle. This system consists of a solution-transmitting unit and an optical unit. The solution-transmitting unit allows a sample containing particles to flow through the center of a flow cell by hydrodynamic focusing. The optical unit irradiates particles with dispersed white light (wavelength band: 400-650 nm) along the flow direction and measures their fluorescence spectra (wavelength band: 400-700 nm) using a spectroscopic photodetector array. The fluorescence spectrum of a particle changes with the shift of the wavelength of the excitation light. Using this system, the excitation-fluorescence spectra of a fluorescent particle were measured. Additionally, a homogenized tomato suspension and a homogenized spinach suspension were measured using the system. Measurement results show that it is possible to determine the components of vegetables by comparing measured fluorescence spectra of particles in a vegetable suspension.

  9. Non-mechanical optical path switching and its application to dual beam spectroscopy including gas filter correlation radiometry

    NASA Technical Reports Server (NTRS)

    Sachse, Glen W. (Inventor); Wang, Liang-Guo (Inventor)

    1992-01-01

    A non-mechanical optical switch is developed for alternately switching a monochromatic or quasi-monochromatic light beam along two optical paths. A polarizer polarizes light into a single, e.g., vertical component which is then rapidly modulated into vertical and horizontal components by a polarization modulator. A polarization beam splitter then reflects one of these components along one path and transmits the other along the second path. In the specific application of gas filter correlation radiometry, one path is directed through a vacuum cell and one path is directed through a gas correlation cell containing a desired gas. Reflecting mirrors cause these two paths to intersect at a second polarization beam splitter which reflects one component and transmits the other to recombine them into a polarization modulated beam which can be detected by an appropriate single sensor.

  10. Device for translating negative film image to a line scan

    DOEpatents

    Dutton, G.W.

    1998-05-19

    A negative film reader records high-resolution optical density changes across negative film radiographic images to allow precise image dimensions to be determined. A laser light source capable of high-resolution focusing is passed through an intensity control filter, focused by a lens, and reflected off a mirror to focus in the plane of the negative film. The light transmitted through the film is collected by a second lens and directed to a photo diode detector which senses the transmitted intensity. The output of the photo diode signal amplifier is sent to the Y-axis input of an X-Y recorder. The film sample is transported in a plane perpendicular to the beam axis by means of a slide. The film position is monitored, with the signal amplified and recorded as the X-axis on the X-Y recorder. The linear dimensions and positions of image components can be determined by direct measurement of the amplified recording.

  11. Multiple bio-monitoring system using visible light for electromagnetic-wave free indoor healthcare

    NASA Astrophysics Data System (ADS)

    An, Jinyoung; Pham, Ngoc Quan; Chung, Wan-Young

    2017-12-01

    In this paper, a multiple biomedical data transmission system with visible light communication (VLC) is proposed for an electromagnetic-wave-free indoor healthcare. VLC technology has emerged as an alternative solution to radio-frequency (RF) wireless systems, due to its various merits, e.g., ubiquity, power efficiency, no RF radiation, and security. With VLC, critical bio-medical signals, including electrocardiography (ECG), can be transmitted in places where RF radiation is restricted. This potential advantage of VLC could save more lives in emergency situations. A time hopping (TH) scheme is employed to transfer multiple medical-data streams in real time with a simple system design. Multiple data streams are transmitted using identical color LEDs and go into an optical detector. The received multiple data streams are demodulated and rearranged using a TH-based demodulator. The medical data is then monitored and managed to provide the necessary medical care for each patient.

  12. Study of optical materials to be used on Multi Element Telescope for Imaging and Spectroscopy instrument

    NASA Astrophysics Data System (ADS)

    Nardello, Marco; Zuccon, Sara; Corso, Alain Jodi; Zuppella, Paola; Gerlin, Francesca; Tessarolo, Enrico; Pelizzo, Maria Guglielmina

    2015-04-01

    The European Space Agency mission Solar Orbiter (SOLO) is dedicated to the study of the solar atmosphere and heliosphere. As a part of the payload, the instrument METIS (Multi Element Telescope for Imaging and Spectroscopy) will provide images of the corona, both in the visible range and at the hydrogen Lyman-α emission line (121.6 nm). The realization of optical coatings, based on Al and MgF2, able to reflect/transmit such spectral components is, therefore, necessary. Since optical characteristics of materials in the vacuum ultraviolet range are not well studied and vary greatly with the realization process, we implemented a study of their properties in different deposition conditions. This is aimed to the realization of a custom designed filter able to transmit the 121.6 nm wavelength while reflecting visible light, and thus separating visible from ultraviolet light paths in the METIS instrument.

  13. Light-weight cyptography for resource constrained environments

    NASA Astrophysics Data System (ADS)

    Baier, Patrick; Szu, Harold

    2006-04-01

    We give a survey of "light-weight" encryption algorithms designed to maximise security within tight resource constraints (limited memory, power consumption, processor speed, chip area, etc.) The target applications of such algorithms are RFIDs, smart cards, mobile phones, etc., which may store, process and transmit sensitive data, but at the same time do not always support conventional strong algorithms. A survey of existing algorithms is given and new proposal is introduced.

  14. Optical-Fiber Fluorosensors With Polarized Light Sources

    NASA Technical Reports Server (NTRS)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  15. Polarization-sensitive descending neurons in the locust: connecting the brain to thoracic ganglia.

    PubMed

    Träger, Ulrike; Homberg, Uwe

    2011-02-09

    Many animal species, in particular insects, exploit the E-vector pattern of the blue sky for sun compass navigation. Like other insects, locusts detect dorsal polarized light via photoreceptors in a specialized dorsal rim area of the compound eye. Polarized light information is transmitted through several processing stages to the central complex, a brain area involved in the control of goal-directed orientation behavior. To investigate how polarized light information is transmitted to thoracic motor circuits, we studied the responses of locust descending neurons to polarized light. Three sets of polarization-sensitive descending neurons were characterized through intracellular recordings from axonal fibers in the neck connectives combined with single-cell dye injections. Two descending neurons from the brain, one with ipsilaterally and the second with contralaterally descending axon, are likely to bridge the gap between polarization-sensitive neurons in the brain and thoracic motor centers. In both neurons, E-vector tuning changed linearly with daytime, suggesting that they signal time-compensated spatial directions, an important prerequisite for navigation using celestial signals. The third type connects the suboesophageal ganglion with the prothoracic ganglion. It showed no evidence for time compensation in E-vector tuning and might play a role in flight stabilization and control of head movements.

  16. Tri-functional cannula for retinal endovascular surgery

    DOEpatents

    Weiss, Jonathan D [Albuquerque, NM

    2010-07-27

    A tri-functional cannula combines the functions of tissue Plasminogen Activator (tPA) solution delivery, illumination and venous pressure measurement. The cannula utilizes a tapered hollow-core optical fiber having an inlet for tPA solution, an attached fiber optic splitter configured to receive illumination light from an optical source such and a LED. A window in the cannula transmits the light to and from a central retinal vein. The return light is coupled to an optical detector to measure the pressure within the vein and determine whether an occlusion has been removed.

  17. Quartz and E-glass fiber self-sensing composites

    NASA Astrophysics Data System (ADS)

    Zolfaghar, K.; Khan, N. A.; Brooks, David; Hayes, Simon A.; Liu, Tonguy; Roca, J.; Lander, J.; Fernando, Gerard F.

    1998-04-01

    This paper reports on developments in the field of self- sensing fiber reinforced composites. The reinforcing fibers have been surface treated to enable them to act as light guides for short distances. The reinforcing fiber light guides were embedded in carbon fiber reinforced epoxy prepregs and processed into composites. The resultant composite was termed the self-sensing composite as any damage to these fibers or its interface would result in the attenuation of the transmitted light. The self-sensing fibers were capable of detecting a 2 J impact.

  18. Optical switch

    DOEpatents

    Reedy, R.P.

    1985-01-18

    An optical switching device is provided whereby light from a first glass fiber or a second glass fiber may be selectively transmitted into a third glass fiber. Each glass fiber is provided with a focusing and collimating lens system. In one mode of operation, light from the first glass fiber is reflected by a planar mirror into the third glass fiber. In another mode of operation, light from the second glass fiber passes directly into the third glass fiber. The planar mirror is attached to a rotatable table which is rotated to provide the optical switching.

  19. Optical switch

    DOEpatents

    Reedy, R.P.

    1987-11-10

    An optical switching device is provided whereby light from a first glass fiber or a second glass fiber may be selectively transmitted into a third glass fiber. Each glass fiber is provided with a focusing and collimating lens system. In one mode of operation, light from the first glass fiber is reflected by a planar mirror into the third glass fiber. In another mode of operation, light from the second glass fiber passes directly into the third glass fiber. The planar mirror is attached to a rotatable table which is rotated to provide the optical switching. 3 figs.

  20. Photovoltaic module with light reflecting backskin

    DOEpatents

    Gonsiorawski, Ronald C [Danvers, MA

    2007-07-03

    A photovoltaic module comprises electrically interconnected and mutually spaced photovoltaic cells that are encapsulated by a light-transmitting encapsulant between a light-transparent front cover and a back cover, with the back cover sheet being an ionomer/nylon alloy embossed with V-shaped grooves running in at least two directions and coated with a light reflecting medium so as to provide light-reflecting facets that are aligned with the spaces between adjacent cells and oriented so as to reflect light falling in those spaces back toward said transparent front cover for further internal reflection onto the solar cells, whereby substantially all of the reflected light will be internally reflected from said cover sheet back to the photovoltaic cells, thereby increasing the current output of the module. The internal reflector improves power output by as much as 67%.

  1. Design and implementation of green intelligent lights based on the ZigBee

    NASA Astrophysics Data System (ADS)

    Gan, Yong; Jia, Chunli; Zou, Dongyao; Yang, Jiajia; Guo, Qianqian

    2013-03-01

    By analysis of the low degree of intelligence of the traditional lighting control methods, the paper uses the singlechip microcomputer for the control core, and uses a pyroelectric infrared technology to detect the existence of the human body, light sensors to sense the light intensity; the interface uses infrared sensor module, photosensitive sensor module, relay module to transmit the signal, which based on ZigBee wireless network. The main function of the design is to realize that the lighting can intelligently adjust the brightness according to the indoor light intensity when people in door, and it can turn off the light when people left. The circuit and program design of this system is flexible, and the system achieves the effect of intelligent energy saving control.

  2. Stochastic theory of polarized light in nonlinear birefringent media: An application to optical rotation

    NASA Astrophysics Data System (ADS)

    Tsuchida, Satoshi; Kuratsuji, Hiroshi

    2018-05-01

    A stochastic theory is developed for the light transmitting the optical media exhibiting linear and nonlinear birefringence. The starting point is the two-component nonlinear Schrödinger equation (NLSE). On the basis of the ansatz of “soliton” solution for the NLSE, the evolution equation for the Stokes parameters is derived, which turns out to be the Langevin equation by taking account of randomness and dissipation inherent in the birefringent media. The Langevin equation is converted to the Fokker-Planck (FP) equation for the probability distribution by employing the technique of functional integral on the assumption of the Gaussian white noise for the random fluctuation. The specific application is considered for the optical rotation, which is described by the ellipticity (third component of the Stokes parameters) alone: (i) The asymptotic analysis is given for the functional integral, which leads to the transition rate on the Poincaré sphere. (ii) The FP equation is analyzed in the strong coupling approximation, by which the diffusive behavior is obtained for the linear and nonlinear birefringence. These would provide with a basis of statistical analysis for the polarization phenomena in nonlinear birefringent media.

  3. fDOT for in vivo follow-up of tumor development in mice lungs

    NASA Astrophysics Data System (ADS)

    Koenig, Anne; Hervé, Lionel; Da Silva, Anabela; Dinten, Jean-Marc; Boutet, Jérôme; Berger, Michel; Josserand, Véronique; Coll, Jean-Luc; Peltié, Philippe; Rizo, Philippe

    2007-07-01

    This paper presents in vivo experiments conducted on cancerous mice bearing mammary murine tumors. In order to reconstruct the fluorescence yield even in highly attenuating and heterogeneous regions like lungs, we developed a fDOT reconstruction method which at first corrects the light propagation model from optical heterogeneities by using the transmitted excitation light measurements. The same approach is also designed to enable working without immersing the mouse in adaptation liquid. The 3D fluorescence map is then reconstructed from the emitted signal of fluorescence and from the corrected propagation model by an ART (Algebraic Reconstruction Technique) algorithm. The system ability to reconstruct fluorescence distribution in presence of high attenuating objects has been validated on phantoms presenting a fluorescent absorbent inclusion. A study was conducted on mice to follow up lungs at different stages of tumor development. The mice were imaged after intravenous injection to the animal of a cancer specific fluorescent marker. A control experiment was conducted in parallel on healthy mice to ensure that the multiple injections of fluorophore did not induce parasite fluorescence distribution. These results validate our system performances for studying small animal lungs tumor evolution. Detection and localization of the fluorophore fixations expresses the tumor development.

  4. Miniaturized optoelectronic system for telemetry of in vivo voltammetric signals.

    PubMed

    De Simoni, M G; De Luigi, A; Imeri, L; Algeri, S

    1990-08-01

    In vivo voltammetry is an electrochemical technique that uses carbon fiber microelectrodes stereotaxically implanted in brain areas to monitor monoamine metabolism and release continuously, in freely moving animals. Electric wires connect the polarograph to the animal. A wire-less transmission system (optoelectronic transmission, OPT) of voltammetric signals is described here. It uses infrared diffused light, exploiting the diffusion of the transmitted light over walls and ceiling towards a receiver. The transmission system consists of a main unit and a satellite unit (40 x 30 x 5 mm) positioned on the animal's back. Voltammetric recordings obtained by the classical system (with wires) and by OPT are well defined and almost identical in shape. The power supply is provided by two thin lithium batteries (+/- 3V) that can record for up to 20 h. OPT permits detailed behavioral observations since the animal can be left free to move in a spacious environment. Voltammetry using OPT allows simultaneous recording of neuronal firing activity as well as electroencephalographic recordings (EEG) since there is no cross-talk between the circuits used. The results illustrate the reliability and usefulness of this wire-less transmission system for studying relationships between neurochemical, behavioral and electrophysiological activities.

  5. An optical fiber guided ultrasonic excitation and sensing system for online monitoring of nuclear power plants

    NASA Astrophysics Data System (ADS)

    Yang, J.; Lee, H.; Sohn, H.

    2012-05-01

    This study presents an embedded laser ultrasonic system for pipeline monitoring under high temperature environment. Recently, laser ultrasonics is becoming popular because of their advantageous characteristics such as (a) noncontact inspection, (b) immunity against electromagnetic interference (EMI), and (c) applicability under high temperature. However, the performance of conventional laser ultrasonic techniques for pipeline monitoring has been limited because many pipelines are covered by insulating materials and target surfaces are inaccessible. To overcome the problem, this study designs an embeddable optical fibers and fixing devices that deliver laser beams from laser sources to a target pipe using embedded optical fibers. For guided wave generation, an optical fiber is furnished with a beam collimator for irradiating a laser beam onto a target structure. The corresponding response is measured based on the principle of laser interferometry. Light from a monochromatic source is colliminated and delivered to a target surface by another optical with a focusing module, and reflected light is transmitted back to the interferometer through the same fiber. The feasibility of the proposed system for embedded ultrasonic measurement has been experimentally verified using a pipe specimen under high temperature.

  6. Application of infrared radiometers for airborne detection of clear air turbulence and low level wind shear, airborne infrared low level wind shear detection test

    NASA Technical Reports Server (NTRS)

    Kuhn, P. M.

    1985-01-01

    The feasibility of infrared optical techniques for the advance detection and avoidance of low level wind shear (LLWS) or low altitude wind shear hazardous to aircraft operations was investigated. A primary feasibility research effort was conducted with infrared detectors and instrumentation aboard the NASA Ames Research Center Learjet. The main field effort was flown on the NASA-Ames Dryden B57B aircraft. The original approach visualized a forward-looking, infrared transmitting (KRS-5) window through which signals would reach the detector. The present concept of a one inch diameter light pipe with a 45 deg angled mirror enables a much simpler installation virtually anywhere on the aircraft coupled with the possibility of horizontal scanning via rotation of the forward directed mirror. Present infrared detectors and filters would certainly permit ranging and horizontal scanning in a variety of methods. CRT display technology could provide a contoured picture with possible shear intensity levels from the infrared detection system on the weather radar or a small adjunct display. This procedure shoud be further developed and pilot evaluated in a light aircraft such as a Cessna 207 or equivalent.

  7. Atomic magnetometer

    DOEpatents

    Schwindt, Peter [Albuquerque, NM; Johnson, Cort N [Albuquerque, NM

    2012-07-03

    An atomic magnetometer is disclosed which uses a pump light beam at a D1 or D2 transition of an alkali metal vapor to magnetically polarize the vapor in a heated cell, and a probe light beam at a different D2 or D1 transition to sense the magnetic field via a polarization rotation of the probe light beam. The pump and probe light beams are both directed along substantially the same optical path through an optical waveplate and through the heated cell to an optical filter which blocks the pump light beam while transmitting the probe light beam to one or more photodetectors which generate electrical signals to sense the magnetic field. The optical waveplate functions as a quarter waveplate to circularly polarize the pump light beam, and as a half waveplate to maintain the probe light beam linearly polarized.

  8. Fiber optic lighting system for plant production

    NASA Astrophysics Data System (ADS)

    St. George, Dennis R.; Feddes, John J. R.

    1991-02-01

    Dennis St. George John Feddes (Dept. of Agricultural Engineering University of Alberta Edmonton AB Canada T6G 2Hl) A prototype light collection and transmission device was developed and evaluated for the potential of irradiating plants grown in an opague growth chamber. Results indicated that the device transmitted light with a photon flux of 130 1amol/s/m2 (4000-7000 nm) to the bottom of the growth chamber when direct solar radiation was 800 W/m2 (300-2500 nm) outside. The overall collection and transmission efficiency for photosynthetically active radiation is 19. 2. A growth trial with plants indicated that artificial lighting is required during cloudy periods. 1.

  9. Fiber optic temperature sensor

    NASA Technical Reports Server (NTRS)

    Sawatari, Takeo (Inventor); Gaubis, Philip A. (Inventor)

    2000-01-01

    A fiber optic temperature sensor uses a light source which transmits light through an optical fiber to a sensor head at the opposite end of the optical fiber from the light source. The sensor head has a housing coupled to the end of the optical fiber. A metallic reflective surface is coupled to the housing adjacent the end of the optical fiber to form a gap having a predetermined length between the reflective surface and the optical fiber. A detection system is also coupled to the optical fiber which determines the temperature at the sensor head from an interference pattern of light which is reflected from the reflective surface.

  10. Fiber optic temperature sensor

    NASA Technical Reports Server (NTRS)

    Sawatari, Takeo (Inventor); Gaubis, Philip A. (Inventor); Mattes, Brenton L. (Inventor); Charnetski, Clark J. (Inventor)

    1999-01-01

    A fiber optic temperature sensor uses a light source which transmits light through an optical fiber to a sensor head at the opposite end of the optical fiber from the light source. The sensor head has a housing coupled to the end of the optical fiber. A metallic reflective surface is coupled to the housing adjacent the end of the optical fiber to form a gap having a predetermined length between the reflective surface and the optical fiber. A detection system is also coupled to the optical fiber which determines the temperature at the sensor head from an interference pattern of light which is reflected from the reflective surface.

  11. Polarized vacuum ultraviolet and X-radiation

    NASA Technical Reports Server (NTRS)

    Samson, J. A. R.

    1978-01-01

    The most intense source of polarized vacuum UV and X radiation is synchrotron radiation, which exhibits a degree of partially polarized light between about 80-100%. However, the radiation transmitted by vacuum UV monochromators can also be highly polarized. The Seya-Namioka type of monochromator can produce partially polarized radiation between 50-80%. For certain experiments it is necessary to know the degree of polarization of the radiation being used. Also, when synchrotron radiation and a monochromator are combined the polarization characteristic of both should be known in order to make full use of these polarization properties. The polarizing effect of monochromators (i.e., diffraction gratings) have been measured at the Seya angle and at grazing angles for various spectral orders. Experimental evidence is presented which shows that the reciprocity law holds for polarization by reflection where the angle of incidence and diffraction are unequal. These results are reviewed along with the techniques for measuring the degree of polarization.

  12. Optical diagnostics of mercury jet for an intense proton target.

    PubMed

    Park, H; Tsang, T; Kirk, H G; Ladeinde, F; Graves, V B; Spampinato, P T; Carroll, A J; Titus, P H; McDonald, K T

    2008-04-01

    An optical diagnostic system is designed and constructed for imaging a free mercury jet interacting with a high intensity proton beam in a pulsed high-field solenoid magnet. The optical imaging system employs a backilluminated, laser shadow photography technique. Object illumination and image capture are transmitted through radiation-hard multimode optical fibers and flexible coherent imaging fibers. A retroreflected illumination design allows the entire passive imaging system to fit inside the bore of the solenoid magnet. A sequence of synchronized short laser light pulses are used to freeze the transient events, and the images are recorded by several high speed charge coupled devices. Quantitative and qualitative data analysis using image processing based on probability approach is described. The characteristics of free mercury jet as a high power target for beam-jet interaction at various levels of the magnetic induction field is reported in this paper.

  13. New laser system for highly sensitive clinical pulse oximetry

    NASA Astrophysics Data System (ADS)

    Hamza, Mostafa; Hamza, Mohammad

    1996-04-01

    This paper describes the theory and design of a new pulse oximeter in which laser diodes and other compact laser sources are used for the measurement of oxygen saturation in patients who are at risk of developing hypoxemia. The technique depends upon illuminating special sites of the skin of the patient with radiation from modulated laser sources at selected wavelengths. The specific laser wavelengths are chosen based on the absorption characteristics of oxyhemoglobin, reduced hemoglobin and other interfering sources for obtaining more accurate measurements. The laser radiation transmitted through the tissue is detected and signal processing based on differential absorption laser spectroscopy is done in such a way to overcome the primary performance limitations of the conventionally used pulse oximetry. The new laser pulse oximeter can detect weak signals and is not affected by other light sources such as surgical lamps, phototherapy units, etc. The detailed description and operating characteristics of this system are presented.

  14. Study of archaeological underwater finds: deterioration and conservation

    NASA Astrophysics Data System (ADS)

    Crisci, G. M.; La Russa, M. F.; Macchione, M.; Malagodi, M.; Palermo, A. M.; Ruffolo, S. A.

    2010-09-01

    This study is aimed at an assessment of the methodologies, instruments and new applications for underwater archaeology. Research focused on study of the various kinds of degradation affecting underwater finds and stone materials aged in underwater environment, efficiency evaluation of various surface cleaning methods and study and mixing of protective products with consolidating resins and antimicrobial biocides to be applied to restored underwater finds. Transmitted light optical microscopy and scanning electron microscopy (SEM) were used to study surface biofilms and the interactions with samples of different stone materials such as brick, marble and granite immersed in the submarine archaeological area of Crotone (South of Italy). Surface cleaning tests were performed with application of ion exchange resins, EDTA, hydrogen peroxide and ultrasound techniques. Capillary water absorption, simulated solar ageing and colourimetric measurements were carried out to evaluate hydrophobic and consolidant properties; to assess biocidal efficacy, heterotrophic micro-organisms ( Aspergillus niger) were inoculated on agar plates and growth inhibition was measured.

  15. 25-gauge fibered-needle for label-free fluorescence analysis of breast masses: a first in vivo study

    NASA Astrophysics Data System (ADS)

    Toullec, Alexis; Mathieu, Marie-Christine; Benoit, Charlotte; Farcy, René; Tourasse, Christophe; Boisserie-Lacroix, Martine; Fontaine-Aupart, Marie-Pierre; Delaloge, Suzette; Balleyguier, Corinne

    2018-02-01

    Breast lesions diagnosis and characterization need additional cost-effective techniques to avoid unnecessary invasive procedures, such as core needle biopsies, in the case of benign tumors. Endogenous fluorescence is an effective method to highlight in situ metabolic and/or structural changes between cancerous and non-cancerous lesions. In this context, we developed an original set-up, consisting of a 405 nm laser diode transmitting light through a 25 Gauge (0.45 mm x 50mm) 14° sharp fibered needle to excite intranodular fluorophores around the needle tip and providing real-time labelfree fluorescence spectral analysis of lesions from 450 nm to 650 nm. The objective was to help radiologists to classify suspicious masses in vivo and in real-time within the lesion. We reported the results of spectral differences between 14 invasive lobular carcinomas and 6 intraductal papilloma enrolled in a clinical study.

  16. CRISTAPRESS: an optical cell for structure development in high-pressure crystallization.

    PubMed

    Boyer, S A E; Fournier, F E J; Gandin, Ch-A; Haudin, J-M

    2014-01-01

    An original optical high-pressure cell, named CRISTAPRESS, has been especially designed to investigate phase transitions of complex liquids, i.e., polymers, polymer blends, nano-composites, etc. The design of the cell is based on the optical properties of morphological entities through in situ light depolarizing microscopic observations. Pressure up to 200 MPa with a fine temperature control up to 300 °C can be applied. A striking advantage of this cell is the possibility to select the pressure transmitting medium that can be water, silicone oil, a fluid in the supercritical state, etc. The potential of the novel technique was demonstrated by carrying out time-resolved measurements during polymer crystallization induced by water pressure. These preliminary experimental investigations permit to discriminate the role of the barometric and thermal histories on the kinetics of polymer growth, as well as on the subsequent morphologies. It should lead to new reliable crystallization kinetics models.

  17. Portable spectrometer monitors inert gas shield in welding process

    NASA Technical Reports Server (NTRS)

    Grove, E. L.

    1967-01-01

    Portable spectrometer using photosensitive readouts, monitors the amount of oxygen and hydrogen in the inert gas shield of a tungsten-inert gas welding process. A fiber optic bundle transmits the light from the welding arc to the spectrometer.

  18. 76 FR 23506 - Federal Motor Vehicle Safety Standards No. 108; Lamp, Reflective Devices and Associated Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-27

    .... Similarly, the dictionary defines transparent as ``having the property of transmitting light without....gov/files/20836.ztv.html . \\9\\ Webster's Third New International Dictionary. 3. The Lead Time for Wide...

  19. Intensities of Incident and Transmitted Ultraviolet-A Rays through Gafchromic Films

    PubMed Central

    Katsuda, Toshizo; Gotanda, Rumi; Gotanda, Tatsuhiro; Akagawa, Takuya; Tanki, Nobuyoshi; Kuwano, Tadao; Noguchi, Atsushi; Yabunaka, Kouichi

    2017-01-01

    Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV)-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission intensity. Gafchromic EBT3 films were suitable to be used in this study because non-UV protection layers are present on both sides of the film. The film is placed between UV-A ray light-emitting diodes and a probe of a UV meter. Gafchromic EBT3 films were irradiated by UV-A rays for up to 60 min. Data for analysis were obtained in the subsequent 60 min. Images from before and after UV-A irradiation were subtracted. When using 375 nm UV-A, the mean ± standard deviation (SD) of the pixel values in the subtracted image was remarkably high (11,194.15 ± 586.63). However, the UV-A transmissivity remained constant throughout the 60 min irradiation period. The mean ± SD UV-A transmission intensity was 184.48 ± 0.50 μm/cm2. Our findings demonstrate that color density changes in Gafchromic EBT3 films do not affect their UV-A transmission. Therefore, Gafchromic films were irradiated by UV-A rays as a preexposure. PMID:28706354

  20. Split-spectrum intensity-based optical fiber sensors for measurement of microdisplacement, strain, and pressure

    NASA Astrophysics Data System (ADS)

    Wang, Anbo; Miller, Mark S.; Plante, Angela J.; Gunther, Michael F.; Murphy, Kent A.; Claus, Richard O.

    1996-05-01

    A self-referencing technique compensating for fiber losses and source fluctuations in reflective air-gap intensity-based optical fiber sensors is described. A dielectric multilayer short-wave-pass filter is fabricated onto or attached to the output end face of the lead-in-lead-out multimode fiber. The incoming broadband light from a white light or a light-emitting diode is partially reflected at the filter. The transmitted light through the filter projects onto a mirror. The light returning from the reflecting mirror is recoupled into the lead-in-lead-out fiber. These two reflections from the filter and the reflecting mirror are spectrally separated at the detector end. The power ratio of these two reflections is insensitive to source fluctuations and fiber-bending loss. However, because the second optical signal depends on the air-gap separation between the end face of the lead-in-lead-out fiber and the reflecting mirror, the ratio provides the information on the air-gap length. A resolution of 0.13 mu m has been obtained over a microdisplacement measurement range of 0-254 mu m. The sensor is shown to be insensitive to both fiber-bending losses and variations in source power. Based on this approach, a fiber-strain sensor was fabricated with a multilayer interference filter directly fabricated on the end face of the fiber. A resolution of 13.4 microstrain was obtained over a measurement range of 0-20,000 microstrain with a gauge length of 10 mm. The split-spectrum method is also incorporated into a diaphragm displacement-based pressure sensor with a demonstrated resolution of 450 Pa over a measurement range of 0-0.8 MPa.

  1. Computation of transmitted and received B1 fields in magnetic resonance imaging.

    PubMed

    Milles, Julien; Zhu, Yue Min; Chen, Nan-Kuei; Panych, Lawrence P; Gimenez, Gérard; Guttmann, Charles R G

    2006-05-01

    Computation of B1 fields is a key issue for determination and correction of intensity nonuniformity in magnetic resonance images. This paper presents a new method for computing transmitted and received B1 fields. Our method combines a modified MRI acquisition protocol and an estimation technique based on the Levenberg-Marquardt algorithm and spatial filtering. It enables accurate estimation of transmitted and received B1 fields for both homogeneous and heterogeneous objects. The method is validated using numerical simulations and experimental data from phantom and human scans. The experimental results are in agreement with theoretical expectations.

  2. Fluorescence emission induced by the femtosecond filament transmitting through the butane/air flame

    NASA Astrophysics Data System (ADS)

    Li, Suyu; Li, Yanhua; Shi, Zhe; Sui, Laizhi; Li, He; Li, Qingyi; Chen, Anmin; Jiang, Yuanfei; Jin, Mingxing

    2018-01-01

    We measure the backward fluorescence spectra generated by the femtosecond filament transmitting through the butane/air flame, and study the fluorescence emission from combustion intermediates (CN, CH and C2 radicals), air (mainly N2 and N2+). It is found that the fluorescence emission from combustion intermediates, N2 and N2+ shows difference when the femtosecond filament transmits through different parts of the butane/air flame, and we attempt to analyze it in this paper. This study demonstrates that the filament-induced fluorescence technique can be utilized to sense the combustion intermediates.

  3. Vaginal microbiome and sexually transmitted infections: an epidemiologic perspective

    PubMed Central

    Brotman, Rebecca M.

    2011-01-01

    Vaginal bacterial communities are thought to help prevent sexually transmitted infections. Bacterial vaginosis (BV) is a common clinical syndrome in which the protective lactic acid–producing bacteria (mainly species of the Lactobacillus genus) are supplanted by a diverse array of anaerobic bacteria. Epidemiologically, BV has been shown to be an independent risk factor for adverse outcomes including preterm birth, development of pelvic inflammatory disease, and acquisition of sexually transmitted infections. Longitudinal studies of the vaginal microbiome using molecular techniques such as 16S ribosomal DNA analysis may lead to interventions that shift the vaginal microbiota toward more protective states. PMID:22133886

  4. Optical clearing of skin using flash lamp-induced enhancement of epidermal permeability.

    PubMed

    Tuchin, V V; Altshuler, G B; Gavrilova, A A; Pravdin, A B; Tabatadze, D; Childs, J; Yaroslavsky, I V

    2006-10-01

    Strong light scattering in skin prevents precise targeting of optical energy in therapeutic and diagnostic applications. Optical immersion based on matching refractive index of scattering centers with that of surrounding matter through introduction of an exogenous index-matching agent can alleviate the problem. However, slow diffusion of the index-matching agent through skin barrier makes practical implementation of this approach difficult. We propose a method of accelerating penetration of the index-matching compounds by enhancing skin permeability through creating a lattice of micro-zones (islets) of limited thermal damage in the stratum corneum (SC). A flash lamp (intense pulsed light) system and an island mask with a pattern of absorbing centers (center size approximately 75-120 microm, lattice pitch approximately 450-500 microm) were used to create the lattice of islets of damage (LID). Index-matching agents, such as glucose solution, propylene glycol solution, and glycerol solution, were applied. Experimental results of optical clearing ex vivo rat and pig skin, and ex vivo and in vivo human skin are presented. Optical transmission spectra of the skin samples with LID were measured during some 2 hours after application of index-matching chemical agents. In order to assess and compare the clearing rate under different treatment and clearing agents we calculated the quantity that we call "relative transmittance": T(rel) = I(t)(lambda)/I(0)(lambda), were I(t)(lambda) is the intensity measured at elapsed time t. The dynamics of relative transmittance of skin samples at 470 and 650 nm shows that the implementation of limited thermal damage technique leads to a 3-10-fold increase of optical clearing (rise of transmittance) rate compared to the results obtained when the samples were treated with high-intensity light pulses but without the use of island damage mask (IDM). It was observed from the plotted spectra of relative transmittance that the maximum increase of transmitted light intensity has been obtained with glucose solution as a clearing agent. Noteworthy is the difference in the trend of spectral curves: relative transmittance spectrum for glycerol reveals, on the whole, a greater slope which may be indicative of higher extent of index matching between the scattering centers and base material for this index-matching agent. Under the transillumination of the skin sample by the wide flat beam the more effective clearing (the increase of transmitted intensity) is attained within the hemoglobin absorption bands; with the narrow quasi-collimated beam the higher relative transmittance was observed over the intervals of minimum absorption. The use of specially designed island mask combined with non-laser intensive pulse irradiation produces a lattice of islands of limited thermal damage in SC that substantially enhances the penetration rate of topically applied index-matching agents. The suggested technique gave comparable magnitudes of clearing dynamics enhancement for glucose solution, glycerol solution, and propylene glycol solution applied to mammalian skin.

  5. Light Transmission of Novel CAD/CAM Materials and Their Influence on the Degree of Conversion of a Dual-curing Resin Cement.

    PubMed

    Egilmez, Ferhan; Ergun, Gulfem; Cekic-Nagas, Isil; Vallittu, Pekka K; Lassila, Lippo V J

    To evaluate the light transmission characteristics of different types, shades, and thicknesses of novel CAD/CAM materials and their effect on the degree of conversion (DC) of a dual-curing resin cement. Square specimens (12 × 12 mm2) of three CAD/CAM materials - GC Cerasmart, Lava Ultimate, Vita Enamic - of different thicknesses (1.00, 1.50, and 2.00 mm, n = 5 per thickness) were irradiated with an LED unit. The amount of transmitted light was quantified. Thereafter, the DC% of the dual-curing resin cement (RelyX Ultimate) was recorded after 15 min using Fourier transform infrared spectroscopy. Statistical analysis was performed using two-way ANOVA followed by the Tukey's HSD post-hoc test at a significance level of p < 0.05. Regression analysis was performed to investigate the correlation between the DC and radiant energy, and the DC and thickness. Although the type and shade of CAD/CAM material significantly affect transmitted light irradiation (p < 0.0001), degrees of conversion are similar when the CAD/CAM material or material shade were taken into consideration (p > 0.05). Conversely, material thickness significantly affected light transmission (p < 0.0001) and DC (p < 0.0001). Multiple effects of material, shade, and thickness did not significantly affect the evaluated parameters (p = 0.638 for light irradiation; p = 0.637 for DC). Linear regression analysis showed a correlation between delivered energy and DC% results of the Vita Enamic (R² = 0.4169, p < 0.0001). Reduced light transmission in 2-mm-thick specimens of all CAD/CAM materials indicates that proper curing of the cement beneath CAD/CAM materials should be ensured.

  6. Light aircraft sound transmission study

    NASA Technical Reports Server (NTRS)

    Atwal, M.; David, J.; Heitman, K.; Crocker, M. J.

    1983-01-01

    The revived interest in the design of propeller driven aircraft is based on increasing fuel prices as well as on the need for bigger short haul and commuter aircraft. A major problem encountered with propeller driven aircraft is propeller and exhaust noise that is transmitted through the fuselage sidewall structure. Part of the work which was conducted during the period April 1 to August 31, 1983, on the studies of sound transmission through light aircraft walls is presented.

  7. Iridescent clouds and distorted coronas.

    PubMed

    Laven, Philip

    2017-07-01

    Near-forward scattering of sunlight generates coronas and iridescence on clouds. Coronas are caused by diffraction, whereas iridescence is less easily explained. Iridescence often appears as bands of color aligned with the edges of clouds or as apparently random patches of color on clouds. This paper suggests that iridescence is due to interference between light that has been diffracted by a spherical droplet of water and light that has been transmitted through the same droplet.

  8. Image compression/decompression based on mathematical transform, reduction/expansion, and image sharpening

    DOEpatents

    Fu, Chi-Yung; Petrich, Loren I.

    1997-01-01

    An image represented in a first image array of pixels is first decimated in two dimensions before being compressed by a predefined compression algorithm such as JPEG. Another possible predefined compression algorithm can involve a wavelet technique. The compressed, reduced image is then transmitted over the limited bandwidth transmission medium, and the transmitted image is decompressed using an algorithm which is an inverse of the predefined compression algorithm (such as reverse JPEG). The decompressed, reduced image is then interpolated back to its original array size. Edges (contours) in the image are then sharpened to enhance the perceptual quality of the reconstructed image. Specific sharpening techniques are described.

  9. Biomimetic hairy surfaces as superhydrophobic highly transmissive films for optical applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Vuellers, Felix; Gomard, Guillaume; Preinfalk, Jan B.; Klampaftis, Efthymios; Worgull, Matthias; Richards, Bryce S.; Hölscher, Hendrik; Kavalenka, Maryna N.

    2017-02-01

    Combining high optical transmission, water-repellency and self-cleaning is of great interest for optoelectronic devices operating in outdoor conditions, such as photovoltaics where shading can significantly reduce the power output. The surface of water plant Pistia stratiotes combines these functionalities through a dense layer of transparent microhairs. It renders the surface superhydrophobic without affecting absorption of sunlight necessary for photosynthesis. Inspired by this surface, we fabricated a superhydrophobic flexible thin nanofur film made from optical grade polycarbonate using a scalable combination of hot embossing and hot pulling techniques. During fabrication, heated sandblasted steel plates locally elongate softened polymer, thus covering its surface in microcavities surrounded by high aspect ratio micro- and nanohairs. The superhydrophobic nanofur exhibits contact angles of (166+/-6°), low sliding angles (<6°) and is self-cleaning against various contaminants. The overall transmission of the self-standing nanofur film stands above 85% over the visible range, with 97% of the transmitted light scattered forward. Reflection drops below 4% when coated on a polymeric substrate, which can enhance light extraction in organic light emitting diodes (OLEDs). We report an increase of more than 10% in luminous efficacy for a nanofur coated OLED compared to a bare device. Finally, the nanofur film can be used for enhancing the incoupling of light to solar cells, while additionally providing self-cleaning properties. Optical coupling of the nanofur to a multi-crystalline silicon solar cell results in a 5.8% gain in photocurrent compared to a bare device under normal incidence.

  10. Transparent building-integrated PV modules. Phase 1: Comprehensive report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-09-28

    This Comprehensive Report encompasses the activities that have been undertaken by Kiss + Cathcart, Architects, in conjunction with Energy Photovoltaics, Incorporated (EPV), to develop a flexible patterning system for thin-film photovoltaic (PV) modules for building applications. There are two basic methods for increasing transparency/light transmission by means of patterning the PV film: widening existing scribe lines, or scribing a second series of lines perpendicular to the first. These methods can yield essentially any degree of light transmission, but both result in visible patterns of light and dark on the panel surface. A third proposed method is to burn a gridmore » of dots through the films, independent of the normal cell scribing. This method has the potential to produce a light-transmitting panel with no visible pattern. Ornamental patterns at larger scales can be created using combinations of these techniques. Kiss + Cathcart, Architects, in conjunction with EPV are currently developing a complementary process for the large-scale lamination of thin-film PVs, which enables building integrated (BIPV) modules to be produced in sizes up to 48 in. x 96 in. Flexible laser patterning will be used for three main purposes, all intended to broaden the appeal of the product to the building sector: To create semitransparent thin-film modules for skylights, and in some applications, for vision glazing.; to create patterns for ornamental effects. This application is similar to fritted glass, which is used for shading, visual screening, graphics, and other purposes; and to allow BIPV modules to be fabricated in various sizes and shapes with maximum control over electrical characteristics.« less

  11. Vehicle Transponder for Preemption of Traffic Lights

    NASA Technical Reports Server (NTRS)

    Foster, Conrad; Bachelder, Aaron

    2006-01-01

    The purpose of this article is to describe, in more detail, the transponder installed in each vehicle that participates in the emergency traffic-light-preemption system described in the immediately preceding article. The transponder (see figure) is a fully autonomous data--collection, data-processing, information-display, and communication subsystem that performs robustly in preemption of traffic lights and monitoring of the statuses of street intersections. This transponder monitors the condition of the emergency vehicle in which it is installed and determines when the vehicle has been placed in an emergency-response condition with its siren and/or warning lights activated. Upon detection of such a condition, the transponder collects real-time velocity and acceleration data from the onboard diagnostic (OBD) computer of the vehicle. For this purpose, the transponder contains an OBD interface circuit, including a microprocessor that determines the manufacturer and model of the vehicle and then sends the appropriate commands to the OBD computer requesting the speed and acceleration data. At the same time, data from an onboard navigation system are collected to determine the location and the heading of the vehicle. Then acceleration, speed, position, and heading data are processed and combined with a vehicle-identification number and the resulting set of data is transmitted to monitoring and control units located at all intersections within communication range. When the unit at an intersection determines that this vehicle is approaching and has priority to preempt the intersection, it transmits a signal declaring the priority and the preemption to all participating vehicles (including this one) in the vicinity. If the unit at the intersection has determined that other participating vehicles are also approaching the intersection, then this unit also transmits, to the vehicle that has priority, a message that the other vehicles are approaching the same intersection. The texts of these messages, plus graphical symbols that show the directions and numbers of the approaching vehicles, are presented on the display panel of a computer that is part of the transponder.

  12. Method and apparatus for remote sensing of molecular species at nanoscale utilizing a reverse photoacoustic effect

    DOEpatents

    Su, Ming [Oviedo, FL; Thundat, Thomas G [Knoxville, TN; Hedden, David [Lenoir City, TN

    2010-02-23

    A method and apparatus for identifying a sample, involves illuminating the sample with light of varying wavelengths, transmitting an acoustic signal against the sample from one portion and receiving a resulting acoustic signal on another portion, detecting a change of phase in the acoustic signal corresponding to the light of varying wavelengths, and analyzing the change of phase in the acoustic signal for the varying wavelengths of illumination to identify the sample. The apparatus has a controlled source for illuminating the sample with light of varying wavelengths, a transmitter for transmitting an acoustic wave, a receiver for receiving the acoustic wave and converting the acoustic wave to an electronic signal, and an electronic circuit for detecting a change of phase in the acoustic wave corresponding to respective ones of the varying wavelengths and outputting the change of phase for the varying wavelengths to allow identification of the sample. The method and apparatus can be used to detect chemical composition or visual features. A transmission mode and a reflection mode of operation are disclosed. The method and apparatus can be applied at nanoscale to detect molecules in a biological sample.

  13. Crystal structure of plant light-harvesting complex shows the active, energy-transmitting state

    PubMed Central

    Barros, Tiago; Royant, Antoine; Standfuss, Jörg; Dreuw, Andreas; Kühlbrandt, Werner

    2009-01-01

    Plants dissipate excess excitation energy as heat by non-photochemical quenching (NPQ). NPQ has been thought to resemble in vitro aggregation quenching of the major antenna complex, light harvesting complex of photosystem II (LHC-II). Both processes are widely believed to involve a conformational change that creates a quenching centre of two neighbouring pigments within the complex. Using recombinant LHC-II lacking the pigments implicated in quenching, we show that they have no particular role. Single crystals of LHC-II emit strong, orientation-dependent fluorescence with an emission maximum at 680 nm. The average lifetime of the main 680 nm crystal emission at 100 K is 1.31 ns, but only 0.39 ns for LHC-II aggregates under identical conditions. The strong emission and comparatively long fluorescence lifetimes of single LHC-II crystals indicate that the complex is unquenched, and that therefore the crystal structure shows the active, energy-transmitting state of LHC-II. We conclude that quenching of excitation energy in the light-harvesting antenna is due to the molecular interaction with external pigments in vitro or other pigment–protein complexes such as PsbS in vivo, and does not require a conformational change within the complex. PMID:19131972

  14. Development of a fluorimeter using laser-induced single-shot fluorescence lifetime spectroscopy

    NASA Astrophysics Data System (ADS)

    Eisum, Niels H.; Lynggaard-Jensen, Anders

    1990-08-01

    The developed laboratory prototype fluorimeter is the first step to a new in-situ instrument, and is based on a pulsed nitrogen laser (pumping a color dye laser and the laserbeam passing through a frequency doubler) with a pulse width less than 1 nsec. With such a short excitation pulse it is possible to measure the exponential decay of the fluorescence from the aromatic compounds and thus determine the fluorescence lifetime-curves, which are typically in the region of 5-40 nsec. The emitted fluorescence is collected simultaneously in 35 channels in the wavelength region 250-600 nm. If the fluorescence falls within the transmission areas of the interference filters in each channel the light will be collected by a plastic light guide (doped PMMA) in the actual channel and transmitted to the channels photo multiplier tube (PMT). (The use of the plastic light guide improves the sensitivity). The signal from the PMT is passed on to a 200 MHz 8-bit flash AID-converter connected to a local memory. From this local memory the digital lifetime curves from each channel are transmitted to a computer for presentation of the 3-dimensional spectrum. This spectrum has been obtained with a single laser shot.

  15. Leaky unstable modes and electromagnetic radiation amplification by an anisotropic plasma slab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vagin, K. Yu., E-mail: vagin@sci.lebedev.ru; Uryupin, S. A., E-mail: uryupin@sci.lebedev.ru

    2015-09-15

    The interaction between electromagnetic radiation and a photoionized plasma slab with an anisotropic electron velocity distribution is studied. It is shown that the fields of leaky modes are amplified due to the development of aperiodic instability in the slab, which leads to an increase in both the reflected and transmitted fields. The transmitted field can significantly increase only if the slab thickness does not exceed the ratio of the speed of light to the electron plasma frequency, whereas there is no upper bound on the slab thickness for the reflected signal to be amplified.

  16. An Archetype Semi-Ring Fabry-Perot (SRFP) Resonator

    NASA Technical Reports Server (NTRS)

    Taghavi-Larigani, Shervin; VanZyl, Jakob

    2009-01-01

    We introduce and demonstrate the generation of a novel resonator, termed Semi-Ring Fabry-Perot (SRFP), that exhibits unique features, such as, its use of one plane mirror, allowing the SRFP to be easily fabricated as a symmetrical device. In addition to its unique features, it exhibits advantages of ring and Fabry-Perot resonators: 1) compared to a ring resonator that only allows a transmitted intensity, the Semi-Ring Fabry-Perot (SRFP) supports standing waves, allowing both a reflected and transmitted intensity; 2) the reflected light spectrum of the SRFP resonator is much narrower than similar Fabry-Perot, implying higher finesse.

  17. Prediction of light aircraft interior sound pressure level from the measured sound power flowing in to the cabin

    NASA Technical Reports Server (NTRS)

    Atwal, Mahabir S.; Heitman, Karen E.; Crocker, Malcolm J.

    1986-01-01

    The validity of the room equation of Crocker and Price (1982) for predicting the cabin interior sound pressure level was experimentally tested using a specially constructed setup for simultaneous measurements of transmitted sound intensity and interior sound pressure levels. Using measured values of the reverberation time and transmitted intensities, the equation was used to predict the space-averaged interior sound pressure level for three different fuselage conditions. The general agreement between the room equation and experimental test data is considered good enough for this equation to be used for preliminary design studies.

  18. Prediction of light aircraft interior sound pressure level using the room equation

    NASA Technical Reports Server (NTRS)

    Atwal, M.; Bernhard, R.

    1984-01-01

    The room equation is investigated for predicting interior sound level. The method makes use of an acoustic power balance, by equating net power flow into the cabin volume to power dissipated within the cabin using the room equation. The sound power level transmitted through the panels was calculated by multiplying the measured space averaged transmitted intensity for each panel by its surface area. The sound pressure level was obtained by summing the mean square sound pressures radiated from each panel. The data obtained supported the room equation model in predicting the cabin interior sound pressure level.

  19. An Open-path Laser Transmissometer for Atmospheric Extinction Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chandran, P. M. Satheesh; Krishnakumar, C. P.; Varma, Ravi

    2011-10-20

    A transmissometer is an optical instrument which measures transmitted intensity of monochromatic light over a fixed pathlength. Prototype of a simple laser transmissometer has been developed for transmission (or extinction) measurements through suspended absorbers and scatterers in the atmosphere over tens of meters. Instrument consists of a continuous green diode pumped solid state laser, transmission optics, photodiode detectors and A/D data acquisition components. A modulated laser beam is transmitted and subsequently reflected and returned to the unit by a retroreflecting mirror assembly placed several tens of meters away. Results from an open-path field measurement of the instrument are described.

  20. Method for enhancing signals transmitted over optical fibers

    DOEpatents

    Ogle, J.W.; Lyons, P.B.

    1981-02-11

    A method for spectral equalization of high frequency spectrally broadband signals transmitted through an optical fiber is disclosed. The broadband signal input is first dispersed by a grating. Narrow spectral components are collected into an array of equalizing fibers. The fibers serve as optical delay lines compensating for material dispersion of each spectral component during transmission. The relative lengths of the individual equalizing fibers are selected to compensate for such prior dispersion. The output of the equalizing fibers couple the spectrally equalized light onto a suitable detector for subsequent electronic processing of the enhanced broadband signal.

  1. Hand held phase-shifting diffraction moire interferometer

    DOEpatents

    Deason, Vance A.; Ward, Michael B.

    1994-01-01

    An interferometer in which a coherent beam of light is generated within a remote case and transmitted to a hand held unit tethered to said remote case, said hand held unit having optical elements for directing a pair of mutually coherent collimated laser beams at a diffraction grating. Data from the secondary or diffracted beams are then transmitted to a separate video and data acquisition system for recording and analysis for load induced deformation or for identification purposes. Means are also provided for shifting the phase of one incident beam relative to the other incident beam and being controlled from within said remote case.

  2. Sexually transmitted diseases in the history of Uganda.

    PubMed

    Lyons, M

    1994-04-01

    First noticed in Uganda in 1863 by a European explorer, sexually transmitted diseases (STDs) were cited as a major cause of morbidity and mortality throughout this century. In 1908 the venereal diseases campaign was launched marking the real introduction of western medicine. By the mid-1920s, the campaign was combined with the medical service but throughout the colonial period (1901-1962) venereal diseases were considered intractable. A 1991 survey revealed alarming incidence rates and in light of the importance of STDs as a co-factor in the transmission of HIV, it is of paramount importance to implement more effective control measures.

  3. Advanced methods for light trapping in optically thin silicon solar cells

    NASA Astrophysics Data System (ADS)

    Nagel, James Richard

    2011-12-01

    The field of light trapping is the study of how best to absorb light in a thin film of material when most light either reflects away at the surface or transmits straight through to the other side. This has tremendous application to the field of photovoltaics where thin silicon films can be manufactured cheaply, but also fail to capture all of the available photons in the solar spectrum. Advancements in light trapping therefore bring us closer to the day when photovoltaic devices may reach grid parity with traditional fossil fuels on the electrical energy market. This dissertation advances our understanding of light trapping by first modeling the effects of loss in planar dielectric waveguides. The mathematical framework developed here can be used to model any arbitrary three-layer structure with mixed gain or loss and then extract the total field solution for the guided modes. It is found that lossy waveguides possess a greater number of eigenmodes than their lossless counterparts, and that these "loss guided" modes attenuate much more rapidly than conventional modes. Another contribution from this dissertation is the exploration of light trapping through the use of dielectric nanospheres embedded directly within the active layer of a thin silicon film. The primary benefit to this approach is that the device can utilize a surface nitride layer serving as an antireflective coating while still retaining the benefits of light trapping within the film. The end result is that light trapping and light injection are effectively decoupled from each other and may be independently optimized within a single photovoltaic device. The final contribution from this work is a direct numerical comparison between multiple light trapping schemes. This allows us to quantify the relative performances of various design techniques against one another and objectively determine which ideas tend to capture the most light. Using numerical simulation, this work directly compares the absorption gains due to embedded nanoparticles, surface textures, antireflective coatings, and plasmonic nanospheres. This work also introduces a new mathematical metric for differentiating between index matching and angular scattering at a textured surface. Such information will prove useful in guiding future scientific efforts in the fields of light trapping and light management in thin film photovoltaics.

  4. Scaling down of a deworming programme among school-age children after a thirty-year successful intervention in the Bolivian Chaco.

    PubMed

    Spinicci, Michele; Macchioni, Fabio; Rojo, David; Gamboa, Herlan; Villagrán, Ana Liz; Vallejos, Yolanda; Strohmeyer, Marianne; Roselli, Mimmo; Gabrielli, Simona; Cancrini, Gabriella; Monasterio, Joaquín; Castellanos, Paul; Paredes, Grover Adolfo; Maury, Sdenka; Zárate, Adolfo; Rocabado, Rodolfo; Olliaro, Piero; Montresor, Antonio; Bartoloni, Alessandro

    2018-04-16

    Preventive chemotherapy is the WHO-recommended control method for soil-transmitted helminthiases. In the Bolivian Chaco, 6-monthly single-dose mebendazole delivery to school-age children achieved a dramatic decrease in soil-transmitted helminthiases prevalence between 1987 and 2013. Consequently, in September 2016, preventive chemotherapy delivery was interrupted in nine rural communities. In compliance with WHO recommendations, we intensified surveillance to monitor soil-transmitted helminthiases prevalence and detect potential changes that would require interventions. We conducted two cross-sectional parasitology surveys 12 months apart (September 2016-2017) among school-age children living in the communities where preventive chemotherapy delivery had been halted. Study design, methods of sampling and sample analysis technique (direct microscopy, Kato-Katz technique) followed WHO recommendations, aiming to obtain data representative of the Bolivian Chaco ecological zone. We collected 426 samples in 2016 and 520 in 2017. Soil-transmitted helminthiasis prevalence was unremarkable: 0.7% (95% CI 0-1.5%) in 2016 and 0.8% (0-1.5%) in 2017. Conversely, the prevalence of tapeworms (13% in 2016, 12% in 2017) and intestinal protozoan infections (81% in 2016 and 75% in 2017) continued to be high. Our findings support the role of preventive chemotherapy in reducing soil-transmitted helminthiases transmission, as otherwise poor hygienic and health conditions persist in the Bolivian Chaco. A national survey, involving areas from all the ecological zones of Bolivia, is now warranted. © 2018 John Wiley & Sons Ltd.

  5. Beam shaping of light sources using circular photonic crystal funnel

    NASA Astrophysics Data System (ADS)

    Kumar, Mrityunjay; Kumar, Mithun; Dinesh Kumar, V.

    2012-10-01

    A novel two-dimensional circular photonic crystal (CPC) structure with a sectorial opening for shaping the beam of light sources was designed and investigated. When combined with light sources, the structure acts like an antenna emitting a directional beam which could be advantageously used in several nanophotonic applications. Using the two-dimensional finite-difference time-domain (2D FDTD) method, we examined the effects of geometrical parameters of the structure on the directional and transmission properties of emitted radiation. Further, we examined the transmitting and receiving properties of a pair of identical structures as a function of distance between them.

  6. Observation of extraordinary optical activity in planar chiral photonic crystals.

    PubMed

    Konishi, Kuniaki; Bai, Benfeng; Meng, Xiangfeng; Karvinen, Petri; Turunen, Jari; Svirko, Yuri P; Kuwata-Gonokami, Makoto

    2008-05-12

    Control of light polarization is a key technology in modern photonics including application to optical manipulation of quantum information. The requisite is to obtain large rotation in isotropic media with small loss. We report on extraordinary optical activity in a planar dielectric on-waveguide photonic crystal structure, which has no in-plane birefringence and shows polarization rotation of more than 25 degrees for transmitted light. We demonstrate that in the planar chiral photonic crystal, the coupling of the normally incident light wave with low-loss waveguide and Fabry-Pérot resonance modes results in a dramatic enhancement of the optical activity.

  7. Sub-nanosecond ranging possibilities of optical radar at various signal levels and transmitted pulse widths

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.

    1971-01-01

    The behavior of the photomultiplier is considered, as well as the method of derivation of the photomultiplier output pulse and its relation to the reflected light pulse width and amplitude, and the calibration of range precision and accuracy. Pulsed laser radars with light pulse widths of 30, 3, and 0.1 nanosec a considered, with the 0.1 nanosec system capable of highest precision in several modes of operation, including a high repetition rate, single photoelectron reception mode. An alternate calibration scheme using a fast, triggerable light pulser is described in detail.

  8. Telescope with a wide field of view internal optical scanner

    NASA Technical Reports Server (NTRS)

    Zheng, Yunhui (Inventor); Degnan, III, John James (Inventor)

    2012-01-01

    A telescope with internal scanner utilizing either a single optical wedge scanner or a dual optical wedge scanner and a controller arranged to control a synchronous rotation of the first and/or second optical wedges, the wedges constructed and arranged to scan light redirected by topological surfaces and/or volumetric scatterers. The telescope with internal scanner further incorporates a first converging optical element that receives the redirected light and transmits the redirected light to the scanner, and a second converging optical element within the light path between the first optical element and the scanner arranged to reduce an area of impact on the scanner of the beam collected by the first optical element.

  9. Laser ablation system, and method of decontaminating surfaces

    DOEpatents

    Ferguson, Russell L.; Edelson, Martin C.; Pang, Ho-ming

    1998-07-14

    A laser ablation system comprising a laser head providing a laser output; a flexible fiber optic cable optically coupled to the laser output and transmitting laser light; an output optics assembly including a nozzle through which laser light passes; an exhaust tube in communication with the nozzle; and a blower generating a vacuum on the exhaust tube. A method of decontaminating a surface comprising the following steps: providing an acousto-optic, Q-switched Nd:YAG laser light ablation system having a fiber optically coupled output optics assembly; and operating the laser light ablation system to produce an irradiance greater than 1.times.10.sup.7 W/cm.sup.2, and a pulse width between 80 and 170 ns.

  10. Inexpensive infrared source improvised from flashlight

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Inexpensive hand-held source of infrared energy is provided by a flashlight bulb coated with a paint which filters out the visible light emitted by the bulb and transmits only infrared radiation. This device can be used for checking infrared sensors and for experimental purposes.

  11. Adjustable Optical-Fiber Attenuator

    NASA Technical Reports Server (NTRS)

    Buzzetti, Mike F.

    1994-01-01

    Adjustable fiber-optic attenuator utilizes bending loss to reduce strength of light transmitted along it. Attenuator functions without introducing measurable back-reflection or insertion loss. Relatively insensitive to vibration and changes in temperature. Potential applications include cable television, telephone networks, other signal-distribution networks, and laboratory instrumentation.

  12. A Pulse Code Modulated Fiber Optic Link Design for Quinault Under-Water Tracking Range.

    DTIC Science & Technology

    1980-09-01

    invented and patented a light-wave communications device, the Photophone . The light beam was acoustically modulated, transmitted through the atmosphere and...a load resistor or feedback resistor. This voltage can be cal- culated by multiplying the received power, the respcnsiv ity and the effective load...frequency is not real critical since the clock, in effect , is synchronized after every eight bits by the timing pulse. The more interesting part of the

  13. Isotropically sensitive optical filter employing atomic resonance transitions

    DOEpatents

    Marling, John B.

    1981-01-01

    An ultra-high Q isotropically sensitive optical filter or optical detector employing atomic resonance transitions. More specifically, atomic resonance transitions utilized in conjunction with two optical bandpass filters provide an optical detector having a wide field of view (.about.2.pi. steradians) and very narrow acceptance bandwidth approaching 0.01 A. A light signal to be detected is transmitted through an outer bandpass filter into a resonantly absorbing atomic vapor, the excited atomic vapor then providing a fluorescence signal at a different wavelength which is transmitted through an inner bandpass filter. The outer and inner bandpass filters have no common transmission band, thereby resulting in complete blockage of all optical signals that are not resonantly shifted in wavelength by the intervening atomic vapor. Two embodiments are disclosed, one in which the light signal raises atoms contained in the atomic vapor from the ground state to an excited state from which fluorescence occurs, and the other in which a pump laser is used to raise the atoms in the ground state to a first excited state from which the light signal then is resonantly absorbed, thereby raising the atoms to a second excited state from which fluorescence occurs. A specific application is described in which an optical detector according to the present invention can be used as an underwater detector for light from an optical transmitter which could be located in an orbiting satellite.

  14. Impact damage monitoring in CFRP using fiber Bragg grating ultrasound sensors

    NASA Astrophysics Data System (ADS)

    Tsuda, Hiroshi; Lee, Jung-Ryul; Eguchi, Shunji

    2006-03-01

    Impact damage in CFRP was monitored by ultrasonic inspection method using small-diameter fiber Bragg grating (FBG) sensors. The FBG ultrasound detection system consisted of broadband light source, FBG sensor and tunable optical filter. Broadband light was launched into the FBG sensor. Light reflected from the FBG sensor was transmitted through the tunable optical filter whose transmissive wavelength range is comparable to the reflected wavelength range of the FBG sensor. The operating wavelength of tunable filter was set to optimize the sensitivity of ultrasound detection. Ultrasound vibration was converted into change in intensity of light transmitted through the filter. A cross-ply carbon fiber-reinforced plastic (CFRP) plate was used as a test specimen for impact damage monitoring. A 6.3 X 9mm2 impact damage was introduced by ball dropping. Both FBG ultrasound sensor and piezoelectric ultrasound transmitter were attached on the CFRP surface. The change in responses to ultrasound excited by either spike signal or toneburst signal before and after impact damage was investigated. In response to ultrasound excited by spike signal, the response after impact damage showed a scattered behavior where the period of response signal got longer. In response to ultrasound excited by toneburst signal, damage signal features scattered and distorted waveform. Experimental results proved that the FBG inspection system could monitor a 6.3 X 9mm2 impact damage in CFRP.

  15. Molecular basis for regulating seasonal reproduction in vertebrates.

    PubMed

    Nishiwaki-Ohkawa, Taeko; Yoshimura, Takashi

    2016-06-01

    Animals that inhabit mid- to high-latitude regions exhibit various adaptive behaviors, such as migration, reproduction, molting and hibernation in response to seasonal cues. These adaptive behaviors are tightly regulated by seasonal changes in photoperiod, the relative day length vs night length. Recently, the regulatory pathway of seasonal reproduction has been elucidated using quail. In birds, deep brain photoreceptors receive and transmit light information to the pars tuberalis in the pituitary gland, which induces the secretion of thyroid-stimulating hormone. Thyroid-stimulating hormone locally activates thyroid hormone via induction of type 2 deiodinase in the mediobasal hypothalamus. Thyroid hormone then induces morphological changes in the terminals of neurons that express gonadotropin-releasing hormone and facilitates gonadotropin secretion from the pituitary gland. In mammals, light information is received by photoreceptors in the retina and neurally transmitted to the pineal gland, where it inhibits the synthesis and secretion of melatonin, which is crucial for seasonal reproduction. Importantly, the signaling pathway downstream of light detection and signaling is fully conserved between mammals and birds. In fish, the regulatory components of seasonal reproduction are integrated, from light detection to neuroendocrine output, in a fish-specific organ called the saccus vasculosus. Various physiological processes in humans are also influenced by seasonal environmental changes. The findings discussed herein may provide clues to addressing human diseases, such as seasonal affective disorder. © 2016 Society for Endocrinology.

  16. A minimax technique for time-domain design of preset digital equalizers using linear programming

    NASA Technical Reports Server (NTRS)

    Vaughn, G. L.; Houts, R. C.

    1975-01-01

    A linear programming technique is presented for the design of a preset finite-impulse response (FIR) digital filter to equalize the intersymbol interference (ISI) present in a baseband channel with known impulse response. A minimax technique is used which minimizes the maximum absolute error between the actual received waveform and a specified raised-cosine waveform. Transversal and frequency-sampling FIR digital filters are compared as to the accuracy of the approximation, the resultant ISI and the transmitted energy required. The transversal designs typically have slightly better waveform accuracy for a given distortion; however, the frequency-sampling equalizer uses fewer multipliers and requires less transmitted energy. A restricted transversal design is shown to use the least number of multipliers at the cost of a significant increase in energy and loss of waveform accuracy at the receiver.

  17. Fluorescence Detection In Electrophoresis

    NASA Astrophysics Data System (ADS)

    Swarner, Susan

    1988-04-01

    Fluorescence detection is in common usage in forensic science laboratories for the visualization of three enzyme markers. The fluorogenic substrates, 4-methylumbelliferyl phosphate, 4-methylutbel-liveryl acetate, and fluorecein diacetate, are acted upon by the enzymes Erythrocyte Acid Phospha, tase, Esterase-D, and Carbonic Anhydrase-III, respectively, to produce compounds visible to the analyst when viewed with transmitted UV light at 365 nm. Additionally, the choice of fluorogenic corn, pounds may help detect a specific enzyme from a related enzyme. One of the responsibilities of a forensic science laboratory may be the analysis of blood for genetically controlled polymorphic enzymes and protein markers. The genetic markers are said to be polymorphic because each exhibits types which can be differentiated and allows for the inclusion or exclusion of possible-donors of the blood. Each genetic marker can be separated into these recognizable types by electrophoresis, a technique which separates compounds based on electrical charges. Electrophoresis is conducted by placing a portion or extract of each bloodstain into a support medium which will conduct electricity. This is known as a plate or membrane. By controlling the pH of the buffer and the potential that is applied to the plate, the analyst can achieve separation of the types within an enzyme marker. The types appear as differing patterns of bands. Once the bloodstain has been subjected to electrophoresis, the enzymes must be visualized. This is generally best accomplished by using the specific activity of the enzyme. For the enzymes described in the present work, the visualization is performed by over-layering the plate with a piece of filter paper that 'has been saturated with the appropriate non-fluorescent substrate and buffer. The bands of enzyme, which is now in discrete patterns, will act upon the non-fluorescent substrate to create a fluorescent compound. The plate is then viewed with transmitted UV light at 365 nm to locate the band patterns which will identify the phenotype of the blood source. The plate should be photographed to record the findings.

  18. Performance Evaluation of Fiber Bragg Gratings at Elevated Temperatures

    NASA Technical Reports Server (NTRS)

    Juergens, Jeffrey; Adamovsky, Grigory; Floyd, Bertram

    2004-01-01

    The development of integrated fiber optic sensors for smart propulsion systems demands that the sensors be able to perform in extreme environments. In order to use fiber optic sensors effectively in an extreme environment one must have a thorough understanding of the sensor s limits and how it responds under various environmental conditions. The sensor evaluation currently involves examining the performance of fiber Bragg gratings at elevated temperatures. Fiber Bragg gratings (FBG) are periodic variations of the refractive index of an optical fiber. These periodic variations allow the FBG to act as an embedded optical filter passing the majority of light propagating through a fiber while reflecting back a narrow band of the incident light. The peak reflected wavelength of the FBG is known as the Bragg wavelength. Since the period and width of the refractive index variation in the fiber determines the wavelengths that are transmitted and reflected by the grating, any force acting on the fiber that alters the physical structure of the grating will change what wavelengths are transmitted and what wavelengths are reflected by the grating. Both thermal and mechanical forces acting on the grating will alter its physical characteristics allowing the FBG sensor to detect both temperature variations and physical stresses, strain, placed upon it. This ability to sense multiple physical forces makes the FBG a versatile sensor. This paper reports on test results of the performance of FBGs at elevated temperatures. The gratings looked at thus far have been either embedded in polymer matrix materials or freestanding with the primary focus of this paper being on the freestanding FBGs. Throughout the evaluation process, various parameters of the FBGs performance were monitored and recorded. These parameters include the peak Bragg wavelength, the power of the Bragg wavelength, and total power returned by the FBG. Several test samples were subjected to identical test conditions to allow for statistical analysis of the data. Test procedures, calibrations, and referencing techniques are presented in the paper along with directions for future research.

  19. Stand-off detection of trace explosives by infrared photothermal imaging

    NASA Astrophysics Data System (ADS)

    Papantonakis, Michael R.; Kendziora, Chris; Furstenberg, Robert; Stepnowski, Stanley V.; Rake, Matthew; Stepnowski, Jennifer; McGill, R. Andrew

    2009-05-01

    We have developed a technique for the stand-off detection of trace explosives using infrared photothermal imaging. In this approach, infrared quantum cascade lasers tuned to strong vibrational absorption bands of the explosive particles illuminate a surface of interest, preferentially heating the explosives material. An infrared focal plane array is used to image the surface and detect a small increase in the thermal intensity upon laser illumination. We have demonstrated the technique using TNT and RDX residues at several meters of stand-off distance under laboratory conditions, while operating the lasers below the eye-safe intensity limit. Sensitivity to explosives traces as small as a single grain (~100 ng) of TNT has been demonstrated using an uncooled bolometer array. We show the viability of this approach on a variety of surfaces which transmit, reflect or absorb the infrared laser light and have a range of thermal conductivities. By varying the incident wavelength slightly, we demonstrate selectivity between TNT and RDX. Using a sequence of lasers at different wavelengths, we increase both sensitivity and selectivity while reducing the false alarm rate. At higher energy levels we also show it is possible to generate vapor from solid materials with inherently low vapor pressures.

  20. Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

    NASA Technical Reports Server (NTRS)

    Mielke, Amy F.; Elam, Kristie A.

    2008-01-01

    A molecular Rayleigh scattering technique was utilized to measure time-resolved gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz. A high power continuous-wave (cw) laser beam was focused at a point in an air flow field and Rayleigh scattered light was collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultipler tubes operated in the photon counting mode allowed high frequency sampling of the total signal level and the circular interference pattern to provide time-resolved density, temperature, and velocity measurements. Mean and rms velocity and temperature, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at the NASA Glenn Research Center (GRC). The Rayleigh measurements are compared with particle image velocimetry data and CFD predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

  1. Parallel hyperspectral image reconstruction using random projections

    NASA Astrophysics Data System (ADS)

    Sevilla, Jorge; Martín, Gabriel; Nascimento, José M. P.

    2016-10-01

    Spaceborne sensors systems are characterized by scarce onboard computing and storage resources and by communication links with reduced bandwidth. Random projections techniques have been demonstrated as an effective and very light way to reduce the number of measurements in hyperspectral data, thus, the data to be transmitted to the Earth station is reduced. However, the reconstruction of the original data from the random projections may be computationally expensive. SpeCA is a blind hyperspectral reconstruction technique that exploits the fact that hyperspectral vectors often belong to a low dimensional subspace. SpeCA has shown promising results in the task of recovering hyperspectral data from a reduced number of random measurements. In this manuscript we focus on the implementation of the SpeCA algorithm for graphics processing units (GPU) using the compute unified device architecture (CUDA). Experimental results conducted using synthetic and real hyperspectral datasets on the GPU architecture by NVIDIA: GeForce GTX 980, reveal that the use of GPUs can provide real-time reconstruction. The achieved speedup is up to 22 times when compared with the processing time of SpeCA running on one core of the Intel i7-4790K CPU (3.4GHz), with 32 Gbyte memory.

  2. Erythrocyte aggregation under high pressure studied by laser photometry and mathematical analysis.

    PubMed

    Toyama, Yoshiharu; Yoshida, Hisashi; Yamamoto, Takao; Dobashi, Toshiaki

    2016-04-01

    The effects of hydrostatic pressure on erythrocyte aggregation have been studied by laser photometry and analysis based on a phenomenological theory. Samples were prepared by suspending swine erythrocytes in their own plasma. A high-pressure vessel consisting of a stainless-steel block with a hole to hold a sample cell and two sapphire windows to allows the passage of a He-Ne laser beam was used in the experimental setup. The suspension was stirred at 1500 rpm to disperse the erythrocytes homogeneously. Immediately after reducing the stirring rate from 1500 rpm to 300 rpm, the transmitted light intensity (I) was recorded every 10 ms under a high pressure of 40-200 MPa. The value of I increased with time (t) owing to erythrocyte aggregation. From the phenomenological theory, the equation ΔI(t)=ΔIeq[1-e(-Kt)/(1-B(1-e(-Kt)))] was derived for the change in the transmitted light intensity (ΔI) due to erythrocyte aggregation, where ΔIeq is the transmitted light intensity in the steady state, K is a time constant and B is a constant that represents the ratio of the number of interaction sites on erythrocyte aggregates at time t to that in the steady state. The observed time courses of ΔI obtained at all pressures could be closely fitted to the theoretical equation. ΔIeq roughly increased with increasing pressure. On the other hand, K and B abruptly decreased above 120 MPa. The growth rate of aggregates decreased above 120 MPa. These results suggest a change in the mechanism of erythrocyte aggregation at approximately 120 MPa. We discuss the physical meaning of the parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Optimum coding techniques for MST radars

    NASA Technical Reports Server (NTRS)

    Sulzer, M. P.; Woodman, R. F.

    1986-01-01

    The optimum coding technique for MST (mesosphere stratosphere troposphere) radars is that which gives the lowest possible sidelobes in practice and can be implemented without too much computing power. Coding techniques are described in Farley (1985). A technique mentioned briefly there but not fully developed and not in general use is discussed here. This is decoding by means of a filter which is not matched to the transmitted waveform, in order to reduce sidelobes below the level obtained with a matched filter. This is the first part of the technique discussed here; the second part consists of measuring the transmitted waveform and using it as the basis for the decoding filter, thus reducing errors due to imperfections in the transmitter. There are two limitations to this technique. The first is a small loss in signal to noise ratio (SNR), which usually is not significant. The second problem is related to incomplete information received at the lowest ranges. An appendix shows a technique for handling this problem. Finally, it is shown that the use of complementary codes on transmission and nonmatched decoding gives the lowest possible sidelobe level and the minimum loss in SNR due to mismatch.

  4. Comparison of the Kato-Katz and FLOTAC techniques for the diagnosis of soil-transmitted helminth infections.

    PubMed

    Habtamu, Kassahun; Degarege, Abraham; Ye-Ebiyo, Yemane; Erko, Berhanu

    2011-12-01

    Decisions on individual or community treatment and evaluation of chemotherapy based control programs depend on parasitological diagnostic techniques. The aim of this study was to compare the accuracy of a single Kato-Katz thick smear and a single FLOTAC for the determination of the prevalence and intensity of soil-transmitted helminth infections. A total of 271 faecal specimens were collected from schoolchildren in Ethiopia, and microscopically examined using the Kato-Katz method (41.7 mg stool per slide) and the FLOTAC technique. The combined results from the Kato-Katz and FLOTAC methods were used as diagnostic 'gold' standard for reference in the analysis. Agreement between the two methods showed kappa values of 0.74, 0.73 and 0.28 for Ascaris lumbricoides, Trichuris trichiura and hookworm, respectively. A single FLOTAC revealed significantly more infections than a single Kato-Katz for each of the three soil-transmitted helminths (p<0.01). The sensitivities of a single Kato-Katz for diagnosis of T. trichiura, A. lumbricoides and hookworm infections were 76.6%, 67.8% and 19.6%, respectively, while the sensitivity of FLOTAC was 100% for all the three soil-transmitted helminth species. A single Kato-Katz yielded considerably higher mean faecal egg counts (FECs) (729.1, 145.2 and 60.7 eggs per gram of stool (EPG) for A. lumbricoides, T. trichiura and hookworm, respectively) compared with a single FLOTAC (142.5, 54.5 and 14.6 EPG, respectively) (p<0.05). Our study confirms that a single FLOTAC is more sensitive than a single Kato-Katz for the diagnosis of soil-transmitted helminth infections, but results in lower FECs. Further standardization and validation are still required in different epidemiological settings with varying levels of intensity of infections before recommending FLOTAC for large-scale community diagnosis. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Calculations of Reflected and Transmitted Radiance for Earth's Atmosphere.

    PubMed

    Plass, G N; Kattawar, G W

    1968-06-01

    The reflected and transmitted radiance of the earth's atmosphere is calculated by Monte Carlo techniques. The exact scattering function for the aerosols is used as calculated from the Mie theory. The aerosol vs height distributions proposed by Elterman and by Kondratiev et al. are compared. The Rayleigh and aerosol scattering events are included in the calculation, as well as the ozone absorption, where appropriate. Results are given at wavelengths of 0.27 micro, 0.3 micro, 0.4 micro, 0.7 micro, and 1.67 micro. The mean optical paths of the reflected and transmitted photons, the flux at the lower boundary, and the planetary albedo are tabulated.

  6. Development of an integrated endoscopic device for multiplexed low coherence interferometry measurements of microbicide gel coating thickness

    NASA Astrophysics Data System (ADS)

    Drake, Tyler K.; Robles, Francisco E.; DeSoto, Michael; Henderson, Marcus H.; Katz, David F.; Wax, Adam P.

    2009-02-01

    Microbicide gels are topical products that have recently been developed to combat sexually transmitted diseases including HIV/AIDS. The extent of gel coverage, thickness, and structure are crucial factors in gel effectiveness. It is necessary to be able to monitor gel distribution and behavior under various circumstances, such as coatis, and over an extended time scale in vivo. We have developed a multiplexed, Fourier-domain low coherence interferometry (LCI) system as a practical method of measuring microbicide gel distribution, with precision and accuracy comparable to currently used fluorometric techniques techniques. The multiplexed system achieved a broad scanning area without the need for a mechanical scanning device, typical of OCT systems, by utilizing six parallel channels with simultaneous data collection. We now propose an imaging module which will allow the integration of the multiplexed LCI system into the current fluorescence system in conjunction with an endoscope. The LCI imaging module will meet several key criteria in order to be compatible with the current system. The fluorescent system features a 4-mm diameter rigid endsoscope enclosed in a 27-mm diameter polycarbonate tube, with a water immersion tip. Therefore, the LCI module must be low-profile as well as water-resistant to fit inside the current design. It also must fulfill its primary function of delivering light from each of the six channels to the gel and collecting backscattered light. The performance of the imaging module will be characterized by scanning a calibration socket which contains grooves of known depths, and comparing these measurements to the fluorometric results.

  7. A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

    PubMed

    Adriany, Gregor; Auerbach, Edward J; Snyder, Carl J; Gözübüyük, Ark; Moeller, Steen; Ritter, Johannes; Van de Moortele, Pierre-François; Vaughan, Tommy; Uğurbil, Kâmil

    2010-06-01

    Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil arrangements hold promise for developing transceiver arrays incorporating large numbers of coil elements. At magnetic field strengths of 7 tesla and higher where the Larmor frequencies of interest can exceed 300 MHz, the coil array design must also overcome the problem of the coil conductor length approaching the RF wavelength. In this study, a novel concentric arrangement of resonance elements built from capacitively-shortened half-wavelength transmission lines is presented. This approach was utilized to construct an array with whole-brain coverage using 16 transceiver elements and 16 receive-only elements, resulting in a coil with a total of 16 transmit and 32 receive channels. (c) 2010 Wiley-Liss, Inc.

  8. Fiber optic laser-induced breakdown spectroscopy sensor for molten material analysis

    DOEpatents

    Zhang, Hansheng; Rai, Awadesh K.; Singh, Jagdish P.; Yueh, Fang-Yu

    2004-07-13

    A fiber optic laser-induced breakdown spectroscopy (LIBS) sensor, including a laser light source, a harmonic separator for directing the laser light, a dichroic mirror for reflecting the laser light, a coupling lens for coupling the laser light at an input of a multimode optical fiber, a connector for coupling the laser light from an output of the multimode optical fiber to an input of a high temperature holder, such as a holder made of stainless steel, and a detector portion for receiving emission signal and analyzing LIBS intensities. In one variation, the multimode optical fiber has silica core and silica cladding. The holder includes optical lenses for collimating and focusing the laser light in a molten alloy to produce a plasma, and for collecting and transmitting an emission signal to the multimode optical fiber.

  9. Comparative data compression techniques and multi-compression results

    NASA Astrophysics Data System (ADS)

    Hasan, M. R.; Ibrahimy, M. I.; Motakabber, S. M. A.; Ferdaus, M. M.; Khan, M. N. H.

    2013-12-01

    Data compression is very necessary in business data processing, because of the cost savings that it offers and the large volume of data manipulated in many business applications. It is a method or system for transmitting a digital image (i.e., an array of pixels) from a digital data source to a digital data receiver. More the size of the data be smaller, it provides better transmission speed and saves time. In this communication, we always want to transmit data efficiently and noise freely. This paper will provide some compression techniques for lossless text type data compression and comparative result of multiple and single compression, that will help to find out better compression output and to develop compression algorithms.

  10. Image compression/decompression based on mathematical transform, reduction/expansion, and image sharpening

    DOEpatents

    Fu, C.Y.; Petrich, L.I.

    1997-12-30

    An image represented in a first image array of pixels is first decimated in two dimensions before being compressed by a predefined compression algorithm such as JPEG. Another possible predefined compression algorithm can involve a wavelet technique. The compressed, reduced image is then transmitted over the limited bandwidth transmission medium, and the transmitted image is decompressed using an algorithm which is an inverse of the predefined compression algorithm (such as reverse JPEG). The decompressed, reduced image is then interpolated back to its original array size. Edges (contours) in the image are then sharpened to enhance the perceptual quality of the reconstructed image. Specific sharpening techniques are described. 22 figs.

  11. Rhabdoviruses in two species of Drosophila: vertical transmission and a recent sweep.

    PubMed

    Longdon, Ben; Wilfert, Lena; Obbard, Darren J; Jiggins, Francis M

    2011-05-01

    Insects are host to a diverse range of vertically transmitted micro-organisms, but while their bacterial symbionts are well-studied, little is known about their vertically transmitted viruses. We have found that two sigma viruses (Rhabdoviridae) recently discovered in Drosophila affinis and Drosophila obscura are both vertically transmitted. As is the case for the sigma virus of Drosophila melanogaster, we find that both males and females can transmit these viruses to their offspring. Males transmit lower viral titers through sperm than females transmit through eggs, and a lower proportion of their offspring become infected. In natural populations of D. obscura in the United Kingdom, we found that 39% of flies were infected and that the viral population shows clear evidence of a recent expansion, with extremely low genetic diversity and a large excess of rare polymorphisms. Using sequence data we estimate that the virus has swept across the United Kingdom within the past ∼11 years, during which time the viral population size doubled approximately every 9 months. Using simulations based on our lab estimates of transmission rates, we show that the biparental mode of transmission allows the virus to invade and rapidly spread through populations at rates consistent with those measured in the field. Therefore, as predicted by our simulations, the virus has undergone an extremely rapid and recent increase in population size. In light of this and earlier studies of a related virus in D. melanogaster, we conclude that vertically transmitted rhabdoviruses may be common in insects and that these host-parasite interactions can be highly dynamic.

  12. The influence of an external electric field on the propagation of light waves in cholesteric liquid crystal cells

    NASA Astrophysics Data System (ADS)

    Aksenova, E. V.; Karetnikov, A. A.; Kovshik, A. P.; Krainyukov, E. S.; Svanidze, A. V.

    2017-05-01

    The specific features of light transmission in a cholesteric liquid crystal (LC) cell with a director rotated by 90° have been investigated. In this structure, where a light wave is incident at a large angle with respect to the LC surface, the light is reflected (refracted) in the LC layer near the opposite boundary. It is shown that the application of an electric field changes the character of extraordinary wave refraction, as a result of which light starts passing through a cell. The transmission threshold voltage is determined, and its dependence on the angle of incidence of light is obtained. The dependence of the transmitted-light intensity on the voltage across the cell is obtained as well. The same dependences are also derived by numerical calculations with allowance for the turning points and extinction.

  13. Interferometric apparatus for ultra-high precision displacement measurement

    NASA Technical Reports Server (NTRS)

    Zhao, Feng (Inventor)

    2004-01-01

    A high-precision heterodyne interferometer measures relative displacement by creating a thermally-insensitive system generally not subject to polarization leakage. By using first and second light beams separated by a small frequency difference (.DELTA.f), beams of light at the first frequency (f.sub.0) are reflected by co-axial mirrors, the first mirror of which has a central aperture through which the light is transmitted to and reflected by the second mirror. Prior to detection, the light beams from the two mirrors are combined with light of the second and slightly different frequency. The combined light beams are separated according to the light from the mirrors. The change in phase (.DELTA..phi.) with respect to the two signals is proportional to the change in distance of Fiducial B by a factor of wavelength (.lambda.) divided by 4.pi. (.DELTA.L=.lambda..DELTA..phi.1/(4.pi.)). In a second embodiment, a polarizing beam splitting system can be used.

  14. Skin Friction Reduction by Micro-Blowing Technique

    NASA Technical Reports Server (NTRS)

    Hwang, Danny P. (Inventor)

    1998-01-01

    A system and method for reducing skin friction of an object in relative motion to a fluid. A skin forming a boundary between the object and the fluid, the skin having holes through which micro-blowing of air is blown and a transmitting mechanism for transmitting air through the skin. The skin has an inner layer and an outer layer. the inner layer being a low permeable porous sheet, the outer layer being a plate having high aspect ratio high porosity. and small holes. The system may further include a suction apparatus for suctioning air from the outer layer. The method includes the steps of transmitting air through the inner layer and passing the air transmitted through the inner layer to the outer layer. The method may further include the step of bleeding air off the outer layer using the suction apparatus.

  15. Chemistry Research of Optical Fibers.

    DTIC Science & Technology

    1982-09-27

    BROADENING IN OPTICAL FIBERS Herbert B. Rosenstock* Naval Research Laboratory Washington, DC 20375 ABSTRACT A light pulse transmitted through a fiber...Marcatili, Marcuse , and Personick, "Dispersion Properties of Fibers" (Ch. 4 in "Optical Fiber Telecommunications," S. E. Miller and A. C. Chynoweth, eds

  16. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam imagemore » to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.« less

  17. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    NASA Astrophysics Data System (ADS)

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.; Kiefer, Jacob; Bazarov, Ivan

    2015-02-01

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam image to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.

  18. Exo-Transmit: Radiative transfer code for calculating exoplanet transmission spectra

    NASA Astrophysics Data System (ADS)

    Kempton, Eliza M.-R.; Lupu, Roxana E.; Owusu-Asare, Albert; Slough, Patrick; Cale, Bryson

    2016-11-01

    Exo-Transmit calculates the transmission spectrum of an exoplanet atmosphere given specified input information about the planetary and stellar radii, the planet's surface gravity, the atmospheric temperature-pressure (T-P) profile, the location (in terms of pressure) of any cloud layers, the composition of the atmosphere, and opacity data for the atoms and molecules that make up the atmosphere. The code solves the equation of radiative transfer for absorption of starlight passing through the planet's atmosphere as it transits, accounting for the oblique path of light through the planetary atmosphere along an Earth-bound observer's line of sight. The fraction of light absorbed (or blocked) by the planet plus its atmosphere is calculated as a function of wavelength to produce the wavelength-dependent transmission spectrum. Functionality is provided to simulate the presence of atmospheric aerosols in two ways: an optically thick (gray) cloud deck can be generated at a user-specified height in the atmosphere, and the nominal Rayleigh scattering can be increased by a specified factor.

  19. Adaptive electron beam shaping using a photoemission gun and spatial light modulator

    DOE PAGES

    Maxson, Jared; Lee, Hyeri; Bartnik, Adam C.; ...

    2015-02-01

    The need for precisely defined beam shapes in photoelectron sources has been well established. In this paper, we use a spatial light modulator and simple shaping algorithm to create arbitrary, detailed transverse laser shapes with high fidelity. We transmit this shaped laser to the photocathode of a high voltage dc gun. Using beam currents where space charge is negligible, and using an imaging solenoid and fluorescent viewscreen, we show that the resultant beam shape preserves these detailed features with similar fidelity. Next, instead of transmitting a shaped laser profile, we use an active feedback on the unshaped electron beam imagemore » to create equally accurate and detailed shapes. We demonstrate that this electron beam feedback has the added advantage of correcting for electron optical aberrations, yielding shapes without skew. The method may serve to provide precisely defined electron beams for low current target experiments, space-charge dominated beam commissioning, as well as for online adaptive correction of photocathode quantum efficiency degradation.« less

  20. Wireless optical network for a home network

    NASA Astrophysics Data System (ADS)

    Bouchet, Olivier; Porcon, Pascal; Walewski, Joachim W.; Nerreter, Stefan; Langer, Klaus-Dieter; Fernández, Luz; Vucic, Jelena; Kamalakis, Thomas; Ntogari, Georgia; Neokosmidis, Ioannis; Gueutier, Eric

    2010-08-01

    During the European collaborative project OMEGA, two optical-wireless prototypes have been developed. The first prototype operates in the near-infrared spectral region and features Giga Ethernet connectivity, a simple transceiver architecture due to the use of on-off keying, a multi-sector transceiver, and an ultra-fast switch for sector-to-sector hand over. This full-duplex system, composed by one base station and one module, transmits data on three meters. The second prototype is a visible-light-communications system based on DMT signal processing and an adapted MAC sublayer. Data rates around to 100 Mb/s at the physical layer are achieved. This broadcast system, composed also by one base station and one module, transmits data up to two meters. In this paper we present the adapted optical wireless media-access-control sublayer protocol for visible-light communications. This protocol accommodates link adaptation from 128 Mb/s to 1024 Mb/s with multi-sector coverage, and half-duplex or full-duplex transmission.

Top