Endovaginal ultrasound; Ultrasound - transvaginal; Fibroids - transvaginal ultrasound; Vaginal bleeding - transvaginal ultrasound; Uterine bleeding - transvaginal ultrasound; Menstrual bleeding - transvaginal ultrasound; ...
Panebianco, Nova; Shofer, Frances; O'Conor, Katie; Wihbey, Tristan; Mulugeta, Lakeisha; Baston, Cameron M; Suzuki, Evan; Alghamdi, Adel; Dean, Anthony
2018-01-30
Emergency department (ED) transvaginal ultrasound (US) is underused in clinical practice. This study assessed pregnant women's perceptions of ED transvaginal US in terms of pain, embarrassment, anxiety, and willingness to receive the procedure. Secondary variables include physicians' perceptions of patients' experiences. Women undergoing US examinations for complications of first-trimester pregnancy were prospectively surveyed before any US and after ED and/or radiology transvaginal US. Patients' and physicians' assessments of pain, embarrassment, and anxiety were measured with visual analog scales (0-100). A total of 398 women were enrolled. In the pre-US survey, the median anxiety score was 14 (interquartile range, 3-51), and 96% of patients were willing to have an ED transvaginal US if necessary. Of those who had ED transvaginal US, 96% would agree to have another examination. Patients reported minimal pain/embarrassment, and there was no difference if performed in the ED versus radiology (median pain, 11.5 versus 13; P = .433; median embarrassment, 7 versus 4; P = .345). Of the 48 who had both ED and radiology transvaginal US, 85% thought the ED transvaginal US was worthwhile. Physicians accurately assessed patient's embarrassment and pain (mean differences, 3.5 and -1.9, respectively; P > .25 for both); however, they overestimated them relative to the pelvic examination (mean difference for embarrassment, 12.8; P < .0001; pain, 8.0; P = .01). Pregnant ED patients report low levels of anxiety, pain, and embarrassment, and after ED transvaginal US, 96% would agree to have the examination again. There is no difference in pain/embarrassment between ED and radiology transvaginal US. Emergency department physicians accurately assessed patients' pain and embarrassment with ED transvaginal US but overestimated them compared to the pelvic examination. © 2018 by the American Institute of Ultrasound in Medicine.
Demers, Marie-Elaine; Dubé, Samuel; Bourdages, Mélodie; Gasse, Cedric; Boutin, Amélie; Girard, Mario; Bujold, Emmanuel; Demers, Suzanne
2018-01-10
To compare the first-trimester uterine artery pulsatility index (PI) measured by abdominal and transvaginal ultrasound (US). We performed a prospective study of singleton pregnant women recruited at 11 to 13 weeks' gestation. The mean uterine artery PI was obtained by abdominal followed by transvaginal US. The mean of the left and right uterine artery PIs was used, and differences between approaches were computed. The intraclass correlation coefficient and a Bland-Altman plot were used to compare the two approaches. Data were available for 940 participants, including 928 (99%) with uterine artery PIs obtained on both uterine sides. The mean uterine artery PI decreased with gestational age in both approaches (P < .001). We observed a moderate correlation between abdominal and transvaginal mean uterine artery PIs (intraclass correlation coefficient, 0.72; 95% confidence interval, 0.69 to 0.75). Values obtained by abdominal US (median, 1.70, interquartile range, 1.35 to 2.09) were greater than those obtained by transvaginal US (median, 1.65; interquartile range, 1.37 to 1.99). There was a significant increase in differences as average measurements became higher (P < .01). The first-trimester mean uterine artery PI decreases with gestational age in both approaches. Abdominal US could be associated with greater uterine artery PI values than transvaginal US, especially at higher measurements. The first-trimester uterine artery PI for prediction of adverse perinatal outcomes should be adjusted for gestational age and possibly for the US approach. © 2018 by the American Institute of Ultrasound in Medicine.
Transvaginal ultrasound in threatened abortions with empty gestational sacs.
Tongsong, T; Wanapirak, C; Srisomboon, J; Sirichotiyakul, S; Polsrisuthikul, T; Pongsatha, S
1994-09-01
To determine whether transvaginal ultrasound criteria alone can distinguish viable from non-viable gestational sacs at a single examination. A prospective descriptive study was undertaken and analysis performed on 211 pregnancies complicated by threatened abortion and empty gestation sacs diagnosed by transvaginal ultrasound. The main outcome measure was the final diagnosis of viable or non-viable gestation on subsequent transvaginal sonography. The study shows that a single transvaginal ultrasound examination is useful in differentiating viable from non-viable gestation sacs. The mean sac diameter (MSD) was found to be the most useful criterion for determining non-viability. An MSD of > or = 17 mm that lacked an embryo and an MSD of > or = 13 mm without visible yolk sac were reliable predictors of non-viable gestation sacs at a single examination with 100% specificity and 100% positive predictive value. An MSD > or = 13 mm without visible yolk sac was the most sensitive criterion. Using MSD criteria, 73% of non-viable gestations could be reliably identified without any false-positive diagnoses. Deformed shape, low position and thin decidual reaction are strong indicators of non-viable gestations but are not 100% accurate. There is still a significant proportion of empty sacs, where no accurate distinction between viable and non-viable can be made according to one criterion at a single examination and in these cases serial examinations should be carried out before any active management is advocated. In most cases, transvaginal sonographic criteria alone can distinguish viable from non-viable empty gestational sacs at a single examination.
Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.
Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A
2016-06-01
The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.
Transvaginal ultrasound (image)
Transvaginal ultrasound is a method of imaging the genital tract in females. A hand held probe is inserted directly ... vaginal cavity to scan the pelvic structures, while ultrasound pictures are viewed on a monitor. The test ...
Esin, Sertac; Yirci, Bulent; Yalvac, Serdar; Kandemir, Omer
2017-07-26
To compare translabial three-dimensional (3D) power Doppler ultrasound with Bishop score and transvaginal ultrasound measurements for cervical assessment before induction of labor with dinoprostone or cervical ripening balloon. Translabial cervical volume and length, vascularization indices and transvaginal cervical length were measured. Results were compared among women who had vaginal delivery at 24 h or less and more than 24 h after the insertion of the dinoprostone vaginal insert or cervical ripening balloon and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. There was no correlation between the time to delivery after a ripening agent was applied and translabial cervical volume, translabial cervical length, vascularization index (VI), flow index (FI), vascularization flow index (VFI), transvaginal cervical length and Bishop scores. The ultrasonographic measurements were no different among women who had vaginal delivery at 24 h or less and more than 24 h and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. In this study, we failed to demonstrate the superiority of translabial 3D ultrasonography over Bishop score and transvaginal ultrasonography for predicting the success of induction of labor.
Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz
2017-01-01
Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017
Transvaginal Ultrasound for the Diagnosis of Abnormal Uterine Bleeding.
Wheeler, Karen C; Goldstein, Steven R
2017-03-01
Transvaginal ultrasound is the first-line imaging test for the evaluation of abnormal uterine bleeding in both premenopausal and postmenopausal women. Transvaginal ultrasound can be used to diagnose structural causes of abnormal bleeding such as polyps, adenomyosis, leiomyomas, hyperplasia, and malignancy, and can also be beneficial in making the diagnosis of ovulatory dysfunction. Traditional 2-dimensional imaging is often enhanced by the addition of 3-dimension imaging with coronal reconstruction and saline infusion sonohysterography. In this article we discuss specific ultrasound findings and technical considerations useful in the diagnosis of abnormal uterine bleeding.
Guidelines for Cleaning Transvaginal Ultrasound Transducers Between Patients.
Abramowicz, Jacques S; Evans, David H; Fowlkes, J Brian; Maršal, Karel; terHaar, Gail
2017-05-01
The purpose of this article is to provide guidance regarding the cleaning and disinfection of transvaginal ultrasound probes. These recommendations are also applicable to transrectal probes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Tonni, Gabriele; Ventura, Alessandro; Bonasoni, Maria Paola
2009-09-01
A 27-year-old pregnant woman was diagnosed by 3D transvaginal ultrasound as carrying a fetus of 9(+5) weeks gestation affected by acrania/encephalocele (exencephaly) sequence. A 2D transvaginal ultrasound-guided aspiration of 5 mL of extra-coelomic fluid was performed under cervical block before uterine suction. Conventional cytogenetic analysis demonstrated a 92,XXXX karyotype. Transvaginal 2D ultrasound-guided coelocentesis for rapid karyotyping can be proposed to women who are near to miscarriage or in cases where a prenatal ultrasound diagnosis of congenital anomaly is performed at an early stage of development. Genetic analysis can be performed using traditional cytogenetic analysis or can be aided by fluorescence in situ hybridization (FISH). Coelocentesis may become an integral part of first trimester armamentarium and may be clinically useful in the understanding of the pathogenesis of early prenatally diagnosed congenital anomalies.
Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M
2015-06-01
Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.
Transvaginal ultrasound-guided embryo transfer in IVF.
Larue, L; Keromnes, G; Massari, A; Roche, C; Moulin, J; Gronier, H; Bouret, D; Cassuto, N G; Ayel, J P
2017-05-01
To determine whether transvaginal ultrasound-guided embryo transfer is a technique that can be used routinely, whether it improves IVF outcomes and whether it makes difficult transfers easier and more successful. Non-randomized retrospective study conducted between 2012 and 2016 in the fertility center of the Diaconesses-Croix St-Simon hospital group. The outcomes of 3910 transfers, performed by 5 senior operators, under transabdominal ultrasound guidance are compared with those of 800 transfers, performed by 1 senior operator under transvaginal ultrasound guidance. The criteria studied are the feasibility of the technique and the percentage of pregnancies per transfer in the two populations described, as well as in the difficult and very difficult transfer populations. All the transfers were feasible under transvaginal ultrasound guidance without the use of forceps or additional instruments. The percentage of pregnancies per transfer is significantly increased, when the transfer is performed under transvaginal ultrasound guidance compared with that performed under transabdominal ultrasound guidance, in the general population (38%, n=800 vs 30%, n=3910; P 0.0004) and in the reference population characterized by age <38 years and >6 oocytes collected per puncture (45%, n=490 vs 36%, n=1968; P 0.002). The percentage of pregnancies per transfer (P/T) is not significantly different in the populations of easy transfers (n 695, 38% P/T), difficult transfers (n 58, 46% P/T; P=ns) and very difficult transfers (n 47, 34% P/T; P=ns). Embryo transfer is a key stage in IVF, in which the quality of performance determines the outcome. In this study, transvaginal ultrasound guidance of the transfer, which is the reference procedure in gynaecological imaging, significantly increases the percentage of pregnancies per transfer, both in the general population and in the reference population, compared with transfers performed under transabdominal ultrasound guidance. Transvaginal ultrasound facilitates the performance of difficult transfers and in particular achieves outcomes in these situations that are not significantly different from those of easy transfers. Visual monitoring of transcervical passage, which is rendered more precise and less traumatic and precision of embryo deposition are the factors that probably account for the improvement in outcomes. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
... based gel on your belly. A hand-held probe is moved over the area. The probe sends out sound waves, which bounce off the ... screen. In a transvaginal ultrasound, a much smaller probe is placed into the vagina. A transvaginal ultrasound ...
Salehi, Hassan S; Wang, Tianheng; Kumavor, Patrick D; Li, Hai; Zhu, Quing
2014-09-01
A novel lens-array based illumination design for a compact co-registered photoacoustic/ultrasound transvaginal probe has been demonstrated. The lens array consists of four cylindrical lenses that couple the laser beams into four 1-mm-core multi-mode optical fibers with optical coupling efficiency of ~87%. The feasibility of our lens array was investigated by simulating the lenses and laser beam profiles using Zemax. The laser fluence on the tissue surface was experimentally measured and was below the American National Standards Institute (ANSI) safety limit. Spatial distribution of hemoglobin oxygen saturation (sO2) of a mouse tumor was obtained in vivo using photoacoustic measurements at multiple wavelengths. Furthermore, benign and malignant ovaries were imaged ex vivo and evaluated histologically. The co-registered images clearly showed different patterns of blood vasculature. These results highlight the clinical potential of our system for noninvasive photoacoustic and ultrasound imaging of ovarian tissue and cancer detection and diagnosis.
Survey of current practice in clinical transvaginal ultrasound scanning in the UK
Shaw, Adam; Lees, Christoph
2015-01-01
During transvaginal ultrasound scanning, the fetus and other sensitive tissues are placed close to the transducer. Heating of these tissues occurs by direct conduction from the transducer and by absorption of ultrasound in the tissue. The extent of any heating will depend on the equipment and settings used, the duration of the scan, imaging modes and other aspects of scanning practice. To ensure that scans are performed with minimum risk, staff should have an appropriate knowledge of safety and follow guidelines issued by professional bodies. An online survey aiming to document current practice in transvaginal ultrasound in the UK was created and distributed to individuals performing this type of scanning. The survey posed questions about the respondents, the departments where scans were performed, the equipment used, knowledge of ultrasound safety, scanning practice and the frequency, duration and mode of transvaginal ultrasound scans for gynaecology, obstetrics and fertility applications. In all, 294 responses were obtained, mostly from sonographers (94%). From the analysis of the responses, it was clear that there was a good understanding of the general meaning of thermal and mechanical index and high awareness of guidelines issued by professional bodies. However, 40% of respondents stated that they rarely or never monitor Thermal or Mechanical indices during scanning. Scanning practice was consistent in terms of the duration of scans, scan protocols followed and use of imaging modes. The results highlight the importance of continued ultrasound safety training and promotion of safety guidelines to users. PMID:27433250
Salehi, Hassan S.; Wang, Tianheng; Kumavor, Patrick D.; Li, Hai; Zhu, Quing
2014-01-01
A novel lens-array based illumination design for a compact co-registered photoacoustic/ultrasound transvaginal probe has been demonstrated. The lens array consists of four cylindrical lenses that couple the laser beams into four 1-mm-core multi-mode optical fibers with optical coupling efficiency of ~87%. The feasibility of our lens array was investigated by simulating the lenses and laser beam profiles using Zemax. The laser fluence on the tissue surface was experimentally measured and was below the American National Standards Institute (ANSI) safety limit. Spatial distribution of hemoglobin oxygen saturation (sO2) of a mouse tumor was obtained in vivo using photoacoustic measurements at multiple wavelengths. Furthermore, benign and malignant ovaries were imaged ex vivo and evaluated histologically. The co-registered images clearly showed different patterns of blood vasculature. These results highlight the clinical potential of our system for noninvasive photoacoustic and ultrasound imaging of ovarian tissue and cancer detection and diagnosis. PMID:25401021
Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.
Ching, Kevin C; Sumkin, Jules H
2015-01-01
Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.
A proposal to reduce the risk of transmission of human papilloma virus via transvaginal ultrasound.
Combs, C Andrew; Fishman, Alan
2016-07-01
Three steps must be followed to prevent the transmission of infection via a contaminated transvaginal ultrasound probe: cleaning the probe after every use, high-level disinfection, and covering the probe with a single-use barrier during the examination. There may be critical flaws in at least 2 of these steps as they are currently practiced. First, 2 widely used disinfectants, glutaraldehyde and orthophthalaldehyde, have recently been found to be ineffective at neutralizing human papilloma virus type 16 and type 18. Second, commercial ultrasound probe covers have an unacceptable rate of leakage (8-81%) compared to condoms (0.9-2%). We recommend the use of a sonicated hydrogen peroxide disinfectant system rather than aldehyde-type disinfectants. We recommend that the probe be covered with a condom rather than a commercial probe cover during transvaginal ultrasound examination. Combined with probe cleaning, these 2 steps are estimated to result in an 800 million- to 250 billion-fold reduction in human papilloma virus viral load, which should translate to greatly enhanced patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.
Fox, R
1999-02-01
The transvaginal ultrasound appearances of the ovary were determined in women with clinical and endocrine features of polycystic ovarian disease (PCOD) and apparently normal women. At scan the number of small follicles were counted and ovarian volume was calculated. The maximum width of the ovarian cortex was also measured. Blood was sent for measurement of LH, FSH and testosterone. The women with oligomenorrhoea were scanned at random and the normal women were seen within the first 5 days of the start of menstruation. There were significant differences between median values for the 2 groups in terms of number of small follicles, ovarian volume and stromal width; the ovaries of the hirsute women had more follicles, were of larger volume, and had greater stromal width. The 2 ranges for number of follicles did overlap, however. Four hirsute oligomenorrhoeic women had a normal number of follicles; all 4 had the several clinical and endocrine features indicative of PCOD. These data suggest that the classical ultrasound features of PCOD are not consistently present and that the absence of increased follicularity at scan should not necessarily deter clinicians from making the functional diagnosis of PCOD.
Güdücü, Nilgün; Sidar, Güliz; İşçi, Herman; Yiğiter, Alin Başgül; Dünder, İlkkan
2013-10-01
To present the indications and diagnosis in adolescents undergoing transrectal ultrasound (RU). Retrospective chart review. Adolescents presenting to gynecology clinic between January 1, 2005 and December 31, 2012. Detection of RU, transvaginal, and transabdominal (AU) ultrasound indications, and final diagnosis. The main indications for RU were menstrual abnormalities, pelvic pain-dysmenorrhea, and vulvovaginitis. When compared according to final diagnosis adolescents with vulvovaginitis (13.9%) and amenorrhea (8.3%) were evaluated more with RU. RU is highly acceptable and it provides images superior to AU. It can be used in adolescents to visualize the pelvic organs and to exclude genital abnormalities and mass lesions. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.
Vasa previa screening strategies: a decision and cost-effectiveness analysis.
Sinkey, R G; Odibo, A O
2018-05-22
The aim of this study is to perform a decision and cost-effectiveness analysis comparing four screening strategies for the antenatal diagnosis of vasa previa among singleton pregnancies. A decision-analytic model was constructed comparing vasa previa screening strategies. Published probabilities and costs were applied to four transvaginal screening scenarios which occurred at the time of mid-trimester ultrasound: no screening, ultrasound-indicated screening, screening pregnancies conceived by in vitro fertilization (IVF), and universal screening. Ultrasound-indicated screening was defined as performing a transvaginal ultrasound at the time of routine anatomy ultrasound in response to one of the following sonographic findings associated with an increased risk of vasa previa: low-lying placenta, marginal or velamentous cord insertion, or bilobed or succenturiate lobed placenta. The primary outcome was cost per quality adjusted life years (QALY) in U.S. dollars. The analysis was from a healthcare system perspective with a willingness to pay (WTP) threshold of $100,000 per QALY selected. One-way and multivariate sensitivity analyses (Monte-Carlo simulation) were performed. This decision-analytic model demonstrated that screening pregnancies conceived by IVF was the most cost-effective strategy with an incremental cost effectiveness ratio (ICER) of $29,186.50 / QALY. Ultrasound-indicated screening was the second most cost-effective with an ICER of $56,096.77 / QALY. These data were robust to all one-way and multivariate sensitivity analyses performed. Within our baseline assumptions, transvaginal ultrasound screening for vasa previa appears to be most cost-effective when performed among IVF pregnancies. However, both IVF and ultrasound-indicated screening strategies fall within contemporary willingness-to-pay thresholds, suggesting that both strategies may be appropriate to apply in clinical practice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Ichizuka, Kiyotake; Mishina, Miyuki; Hasegawa, Junichi; Matsuoka, Ryu; Sekizawa, Akihiko; Pooh, Ritsuko K
2015-05-01
Reported is a fetal Dandy-Walker malformation that was strongly suspected in the first trimester through measurement of the brainstem-vermis (B-V) angle, which was found to be 119° on transvaginal ultrasound examination at 14 weeks and 2 days gestation. Definitive diagnosis of the Dandy-Walker malformation was made by magnetic resonance imaging following stillbirth. Ultrasound measurement of the B-V angle may be a useful index for prenatal diagnosis of Dandy-Walker anomalies during early pregnancy. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.
Apirakviriya, Chayanis; Rungruxsirivorn, Tassawan; Phupong, Vorapong; Wisawasukmongchol, Wirach
2016-05-01
To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Zhao, Hong; Feng, Yi; Jiang, Yan; Lu, Qun
2017-10-01
In this prospective double-blind randomized study, we evaluated the analgesic effect and potential effect on pregnancy rate of the nonsteroidal anti-inflammatory drug flurbiprofen axetil in patients undergoing ultrasound-guided transvaginal oocyte retrieval under propofol-remifentanil anesthesia. A total of 200 patients scheduled to undergo ultrasound-guided transvaginal oocyte retrieval were randomly allocated to receive 1.5 mg/kg of flurbiprofen axetil (FA group) or placebo (control group) 30 minutes before the procedure. Postoperative pain scores, embryo implantation rate, and pregnancy rate were recorded. Neuroendocrine biomarkers and prostaglandin E2 levels in follicular fluid were tested after oocyte retrieval. Patients in the FA group awakened earlier after surgery than patients in the control group (3.3 ± 2.6 vs 5.3 ± 3.4 minutes, P < .05) and had lower pain scores than patients in the control group (2.0 [0.0, 2.8] vs 5.0 [3.0, 5.0], P< .001). The difference in pregnancy rates between the 2 groups (44%-44%) was 0% (conventional 2-sided 95% confidence interval, -13.8% to 13.8%). The lower limit of the 90% 1-sided confidence interval for this difference was -9.0%, which was within the predefined noninferiority margin of -15.0%. The concentration of prostaglandin E2 in follicular fluid was decreased in the FA group (24.51 ± 1.52 vs 25.15 ± 1.49 pg/mL, P = .039), although the difference does not appear to be clinically important. Flurbiprofen axetil given before ultrasound-guided transvaginal oocyte retrieval for patients under propofol-remifentanil general anesthesia relieves pain without any detrimental effect on clinical pregnancy rate.
Ultrasonography of uterine leiomyomas.
Woźniak, Andrzej; Woźniak, Sławomir
2017-12-01
Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan - TVS) or transabdominally (transabdominal scan - TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus.
Ultrasound assessment of bladder wall thickness as a screening test for detrusor instability.
Abou-Gamrah, Amgad; Fawzy, Mounir; Sammour, Hazem; Tadros, Sherif
2014-05-01
The aim of the current study was to evaluate the diagnostic accuracy of transvaginal ultrasound measurement of bladder wall thickness (BWT) in diagnosis of over active bladder (OAB). The current prospective study was conducted at Ain Shams University Maternity Hospital over 2 years. Patients presented to the urogynecology outpatient clinic with symptoms of urinary frequency, urgency, nocturia and/or urge incontinence were included in this study. The allocated patients were divided into two groups; Group 1(study group): fifty (50) patients with urodynamic diagnosis of detrusor instability (OAB) were included. Group 2 (control): fifty (50) patients with urodynamic diagnosis of stress incontinence were included. Using a transvaginal probe, BWT was measured in three sites at the thickest part of (a) the dome of the bladder (b) the trigone, and (c) the anterior wall of the bladder. An average of the three measurements was considered as the mean bladder thickness. A total of 100 patients with lower urinary symptoms were finally analyzed. There were no statistical significant differences between both groups regarding age, parity and body mass index, while there was statistically longer disease duration in group 2. Excluding urgency, there was statistical significant difference (P < 0.001) regarding lower urinary tract symptoms namely frequency, urgency incontinence, coital incontinence and nocturia. Patients in group 1 were more positive to symptoms of frequency, urgency incontinence, and nocturia, while patients in group 2 were more positive regarding coital incontinence. The thickness of trigon, dome, anterior wall and mean BWT was significantly higher in group 1 when compared to group 2. Receiver operator characteristics curve was constructed for estimating the association between mean BWT and prediction of OAB in patients with lower urinary tract symptoms. Mean BWT at 4.78 mm was considered as best cut-off value for prediction of OAB with sensitivity of 90 % and specificity of 78 %. Mean BWT was significantly associated with OAB > 4.78 mm as denoted by the significantly large area under the curve [AUC], AUC was 0.905. In women with lower urinary tract symptom, transvaginal ultrasounds measured mean BWT seems to be an effective non invasive diagnostic tool for prediction of OAB.
Pushkar, Dmitry Y; Vasilchenko, Mikhail I; Kasyan, George R
2013-10-01
Necrotising fasciitis is a severe form of soft tissue infection. Herein, we present an unreported complication of the transvaginal repair of a pelvic organ prolapse (POP) with trocar-guided polypropylene mesh and a concomitant hysterectomy. A 61-year-old Caucasian female who had been using an intrauterine device (IUD) for 30 years presented with a stage 3 pelvic organ prolapse. A genital ultrasound examination confirmed the presence of an IUD, but found no endometrial abnormalities. The surgical management was limited to a transvaginal hysterectomy and simultaneous anterior vaginal wall repair augmented with trocar-guided mesh. A morphological examination of the removed uterus confirmed the presence of the intrauterine device and additionally found endometrial cancer (T1N0M0), which was not revealed during the preoperative ultrasound. Within 6 days of the surgery, she developed anaerobic bilateral necrotising fasciitis on both thighs. Non-clostridial streptococci were identified in the wound. After 18 days of intensive care, the patient died of fatal coagulopathy.
Ultrasonography of uterine leiomyomas
Woźniak, Andrzej
2017-01-01
Uterine leiomyomas or uterine fibroids are the most common gynaecological tumours and occur in about 20-50% of women around the world. Ultrasonography (USG) is the first-line imaging examination in suspected fibroids and shows high sensitivity and specificity in diagnosing this condition. Ultrasound scans can be performed transvaginally (transvaginal scan – TVS) or transabdominally (transabdominal scan – TAS); both scans have advantages and limitations, but, in general, transvaginal sonography is superior to transabdominal sonography in most cases of pelvic pathology. Whether a leiomyoma is symptomatic or not depends primarily on its size and location. During ultrasound examination, leiomyomas usually appear as well-defined, solid, concentric, hypoechoic masses that cause a variable amount of acoustic shadowing. During the examination of leiomyomas differential diagnosis is important. Some of the most common misdiagnosed pathologies are adenomyosis, solid tumours of adnexa, and endometrial polyps. Misdiagnosis of a leiomyosarcoma has the most negative consequences, presenting symptoms are very similar to benign leiomyoma, and there is no pelvic imaging technique that can reliably differentiate between those pathologies. Magnetic resonance and computer tomography might be helpful in the diagnostics of uterine leiomyoma; however, ultrasound examination is the basic imaging test confirming the existence of leiomyomas, allowing the differentiation of myomas with adenomyosis, endometrial polyps, ovarian tumours, and pregnant uterus. PMID:29483851
Cipriano, L E; Barth, W H; Zaric, G S
2010-08-01
To estimate the cost-effectiveness of targeted and universal screening for vasa praevia at 18-20 weeks of gestation in singleton and twin pregnancies. Cost-utility analysis based on a decision-analytic model comparing relevant strategies and life-long outcomes for mother and infant(s). Ontario, Canada. A cohort of pregnant women in 1 year. We constructed a decision-analytic model to estimate the lifetime incremental costs and benefits of screening for vasa praevia. Inputs were estimated from the literature. Costs were collected from the London Health Sciences Centre, the Ontario Health Insurance Program, and other sources. We used one-way, scenario and probabilistic sensitivity analysis to determine the robustness of the results. Incremental costs, life expectancy, quality-adjusted life-years (QALY) and incremental cost-effectiveness ratio (ICER). Universal transvaginal ultrasound screening of twin pregnancies has an ICER of $5488 per QALY-gained. Screening all singleton pregnancies with the risk factors low-lying placentas, in vitro fertilisation (IVF) conception, accessory placental lobes, or velamentous cord insertion has an ICER of $15,764 per QALY-gained even though identifying some of these risk factors requires routine use of colour Doppler during transabdominal examinations. Screening women with a marginal cord insertion costs an additional $27,603 per QALY-gained. Universal transvaginal screening for vasa praevia in singleton pregnancies costs $579,164 per QALY compared with targeted screening. Compared with current practice, screening all twin pregnancies for vasa praevia with transvaginal ultrasound is cost-effective. Among the alternatives considered, the use of colour Doppler at all transabdominal ultrasound examinations of singleton pregnancies and targeted use of transvaginal ultrasound for IVF pregnancies or when the placenta has been found to be associated with one or more risk factors is cost-effective. Universal screening of singleton pregnancies is not cost-effective compared with targeted screening.
We propose to test the validity and specificity of our targeted ultrasound imaging probes in detecting early stage ovarian cancer (OVCA) by transvaginal ultrasound imaging (TVUS). We then test the predictive validity of these probes in a longitudinal study using the laying hen – the only widely available animal model of spontaneous OVCA. OVCA is a fatal gynecological
Buescher, D L; Möllers, M; Falkenberg, M K; Amler, S; Kipp, F; Burdach, J; Klockenbusch, W; Schmitz, R
2016-05-01
Transvaginal and intracavitary ultrasound probes are a possible source of cross-contamination with microorganisms and thus a risk to patients' health. Therefore appropriate methods for reprocessing are needed. This study was designed to compare the standard disinfection method for transvaginal ultrasound probes in Germany with an automated disinfection method in a clinical setting. This was a prospective randomized controlled clinical study of two groups. In each group, 120 microbial samples were collected from ultrasound transducers before and after disinfection with either an automated method (Trophon EPR®) or a manual method (Mikrozid Sensitive® wipes). Samples were then analyzed for microbial growth and isolates were identified to species level. Automated disinfection had a statistically significantly higher success rate of 91.4% (106/116) compared with 78.8% (89/113) for manual disinfection (P = 0.009). The risk of contamination was increased by 2.9-fold when disinfection was performed manually (odds ratio, 2.9 (95% CI, 1.3-6.3)). Before disinfection, bacterial contamination was observed on 98.8% of probes. Microbial analysis revealed 36 different species of bacteria, including skin and environmental bacteria as well as pathogenic bacteria such as Staphylococcus aureus, enterobacteriaceae and Pseudomonas spp. Considering the high number of contaminated probes and bacterial species found, disinfection of the ultrasound probe's body and handle should be performed after each use to decrease the risk of cross-contamination. This study favored automated disinfection owing to its significantly higher efficacy compared with a manual method. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Comparison of two methods of cervical cerclage by ultrasound cervical measurement.
Rozenberg, P; Sénat, M V; Gillet, A; Ville, Y
2003-05-01
To compare the effects of cerclage performed with a modified Shirodkar procedure or with McDonald's technique using transvaginal ultrasound measurement of the distance between the external os and the suture. We performed a retrospective study of all patients who underwent a prophylactic cerclage with either the modified Shirodkar procedure or the McDonald's technique over a 3-year period. Physicians chose the cerclage technique according to their own preferences. Transvaginal ultrasound examination of the cervix was performed 2 weeks after the cerclage to measure its functional length and the distance between the external os and the cerclage. During the study period, 14 patients had a cerclage with the modified Shirodkar procedure and 19 patients with the McDonald's technique. Twelve of these 33 patients (36.4%) delivered before 37 weeks. The obstetric characteristics of the patients in both groups were similar. There were no significant differences between the Shirodkar and McDonald groups as to the functional cervical length before (31.3 +/- 8.7 vs. 35.6 +/- 9.7 mm, respectively) or after (37.0 +/- 7.3 vs. 36.1 +/- 7.9 mm) cerclage, the distance between the external os and cerclage (16.7 +/- 3.8 vs. 14.0 +/- 5.2 mm), or the number of deliveries before 32 (0 vs. 2) and 34 (1 vs. 3) weeks. The anterior colpotomy of the Shirodkar procedure increased the distance between the external os and the cerclage by a mean of 2.7 mm. This slight gain does not justify exposing the patient to the risks related to this procedure. When cerclage is necessary, McDonald's technique seems preferable.
Ultrasound diagnosis of ectopic pregnancy
2015-01-01
Abstract Ectopic pregnancy (EP) remains the number one cause of first trimester maternal death. Traditionally, laparoscopy has been the gold standard for diagnosis of EP. The advent of high‐resolution transvaginal scan (TVS) means more clinically stable women with EPs are diagnosed earlier, well before surgery becomes necessary in many cases. Early diagnosis by TVS is therefore potentially life saving and can reduce surgical morbidity by allowing elective surgery or even non‐surgical conservative treatment options. Combining transabdominal and transvaginal scanning confers no benefit over transvaginal scanning alone. Reports that reads “…empty uterus, ectopic pregnancy cannot be excluded” should be a thing of the past. Diagnosis of EP should be based upon the positive identification of an adnexal mass using TVS rather than the absence of an intra‐uterine gestational sac. A systematic approach to scanning the early pregnancy pelvis will diagnose the vast majority of EPs at the initial scan. Ultrasound, and in particular TVS, is fast becoming the new gold standard for diagnosis of all types of EP. In modern management, laparoscopy should be seen as the operative tool of choice while TVS the diagnostic tool of choice. PMID:28191110
Short, John; Sharp, Benjamin; Elliot, Nikki; McEwing, Rachael; McGeoch, Graham; Shand, Brett; Holland, Kieran
2016-08-01
This observational case series in 65 premenopausal women with abnormal uterine bleeding evaluated whether transvaginal ultrasound followed by saline infusion sonohysterography (SIS) prevented unnecessary hysteroscopy. Although SIS indicated that hysteroscopy was unnecessary in eight women, this benefit was offset by the invasive nature of the scan, the number of endometrial abnormalities falsely detected by SIS and the cost of the additional investigation. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Early pregnancy assessment with transvaginal ultrasound scanning.
Daya, S; Woods, S; Ward, S; Lappalainen, R; Caco, C
1991-01-01
OBJECTIVE: To establish normal parameters in early pregnancy through transvaginal ultrasonography so that gestational age can be determined and to correlate the sonographic findings with serum human chorionic gonadotropin (hCG) levels calibrated against the first international reference preparation standard. SETTING: Infertility clinic. PATIENTS: Thirty-five women with normal intrauterine pregnancy. INTERVENTIONS: Serial measurement of the serum hCG level and the diameter of the gestational sac through transvaginal ultrasonography. MAIN RESULTS: The gestational sac could not be visualized when the hCG level was less than 1100 IU/L. The average growth rate of the sac was 0.9 mm/d. The threshold values for sac diameter, serum hCG level and gestational age below which the yolk sac was not visible were 3.7 mm, 1900 IU/L and 36 days respectively; the corresponding values above which the yolk sac was always visible were 6.7 mm, 5800 IU/L and 40 days. The threshold values below which cardiac activity was not visible were 8.3 mm, 9200 IU/L and 41 days respectively, and the corresponding values above which cardiac activity was always visible were 14.0 mm, 24,000 IU/L and 46 days. The mean gestational ages and the 95% confidence and prediction intervals were tabulated so that measurement of the gestational sac diameter could be used to estimate gestational age early in normal pregnancy. CONCLUSIONS: Transvaginal ultrasonography enables detection of an intrauterine sac and reliable estimation of gestational age on the basis of sac dimensions before an embryo can be seen. PMID:1993291
Zhou, Hui-li; Xiang, Hong; Duan, Li; Shahai, Gulinaer; Liu, Hui; Li, Xiang-hong; Mou, Rui-xue
2015-01-01
Objective. The goal of this study was to explore the clinical value of combining two-dimensional (2D) and three-dimensional (3D) transvaginal contrast-enhanced ultrasounds (CEUS) in diagnosis of endometrial carcinoma (EC). Methods. In this prospective diagnostic study, transvaginal 2D and 3D CEUS were performed on 68 patients with suspected EC, and the results of the obtained 2D-CEUS and 3D-CEUS images were compared with the gold standard for statistical analysis. Results. 2D-CEUS benign endometrial lesions showed the normal uterine perfusion phase while EC cases showed early arrival and early washout of the contrast agent and nonuniform enhancement. The 3D-CEUS images differed in central blood vessel manifestation, blood vessel shape, and vascular pattern between benign and malignant endometrial lesions (P < 0.05). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of transvaginal 2D-CEUS and 2D-CEUS combined with 3D-CEUS for diagnosis of benign and malignant endometrial lesions were 76.9%, 73.8%, 64.5%, 83.8%, and 75.0% and 84.6%, 83.3%, 75.9%, 89.7%, and 83.8%, respectively. Conclusion. 3D-CEUS is a useful supplement to 2D-CEUS and can clearly reveal the angioarchitecture spatial relationships between vessels and depth of myometrial invasion in EC. The combined use of 2D and 3D-CEUS can offer direct, accurate, and comprehensive diagnosis of early EC. PMID:26090396
Chao, Coline; Chalouhi, Gihad E; Bouhanna, Philippe; Ville, Yves; Dommergues, Marc
2015-09-01
To compare the impact of virtual reality simulation training and theoretical teaching on the ability of inexperienced trainees to produce adequate virtual transvaginal ultrasound images. We conducted a randomized controlled trial with parallel groups. Participants included inexperienced residents starting a training program in Paris. The intervention consisted of 40 minutes of virtual reality simulation training using a haptic transvaginal simulator versus 40 minutes of conventional teaching including a conference with slides and videos and answers to the students' questions. The outcome was a 19-point image quality score calculated from a set of 4 images (sagittal and coronal views of the uterus and left and right ovaries) produced by trainees immediately after the intervention, using the same simulator on which a new virtual patient had been uploaded. Experts assessed the outcome on stored images, presented in a random order, 2 months after the trial was completed. They were blinded to group assignment. The hypothesis was an improved outcome in the intervention group. Randomization was 1 to 1. The mean score was significantly greater in the simulation group (n = 16; mean score, 12; SEM, 0.8) than the control group (n = 18; mean score, 9; SEM, 1.0; P= .0302). The quality of virtual vaginal images produced by inexperienced trainees was greater immediately after a single virtual reality simulation training session than after a single theoretical teaching session. © 2015 by the American Institute of Ultrasound in Medicine.
Ovarian Autoantibodies Predict Ovarian Cancer
2010-11-01
2000. 48(10): 541- 549. 10 7. Barua, A., et al., Anti-ovarian and anti-tumor antibodies in women with ovarian cancer. Am J Reprod Immunol, 2007 . 57...Med 2007 . 26: 909-919. 9. Barua, A., et al., Prevalence of anti-tumor antibodies in the laying hen model of human ovarian cancer. International... 2007 ; 25:4159– 4161. 6. Bosse K, Rhiem K, Wappenschmidt B, et al. Screening for ovarian cancer by transvaginal ultrasound and serum CA125 measurement in
Ultrasound imaging of the anal sphincter complex: a review
Abdool, Z; Sultan, A H; Thakar, R
2012-01-01
Endoanal ultrasound is now regarded as the gold standard for evaluating anal sphincter pathology in the investigation of anal incontinence. The advent of three-dimensional ultrasound has further improved our understanding of the two-dimensional technique. Endoanal ultrasound requires specialised equipment and its relative invasiveness has prompted clinicians to explore alternative imaging techniques. Transvaginal and transperineal ultrasound have been recently evaluated as alternative imaging modalities. However, the need for technique standardisation, validation and reporting is of paramount importance. We conducted a MEDLINE search (1950 to February 2010) and critically reviewed studies using the three imaging techniques in evaluating anal sphincter integrity. PMID:22374273
Murphy, Deirdre J; Burke, Gerard; Montgomery, Alan A; Ramphul, Meenakshi
2012-09-13
Instrumental deliveries are commonly performed in the United Kingdom and Ireland, with rates of 12 - 17% in most centres. Knowing the exact position of the fetal head is a pre-requisite for safe instrumental delivery. Traditionally, diagnosis of the fetal head position is made on transvaginal digital examination by delineating the suture lines of the fetal skull and the fontanelles. However, the accuracy of transvaginal digital examination can be unreliable and varies between 20% and 75%. Failure to identify the correct fetal head position increases the likelihood of failed instrumental delivery with the additional morbidity of sequential use of instruments or second stage caesarean section. The use of ultrasound in determining the position of the fetal head has been explored but is not part of routine clinical practice. A multi-centre randomised controlled trial is proposed. The study will take place in two large maternity units in Ireland with a combined annual birth rate of 13,500 deliveries. It will involve 450 nulliparous women undergoing instrumental delivery after 37 weeks gestation. The main outcome measure will be incorrect diagnosis of the fetal head position. A study involving 450 women will have 80% power to detect a 10% difference in the incidence of inaccurate diagnosis of the fetal head position with two-sided 5% alpha. It is both important and timely to evaluate the use of ultrasound to diagnose the fetal head position prior to instrumental delivery before routine use can be advocated. The overall aim is to reduce the incidence of incorrect diagnosis of the fetal head position prior to instrumental delivery and improve the safety of instrumental deliveries. Current Controlled Trials ISRCTN72230496.
Transvaginal Aspiration of Ovarian Cysts: Long-Term Follow-up
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duke, D.; Colville, J.; Keeling, A.
2006-06-15
Background and purpose. Transvaginal aspiration of ovarian cysts has been advocated as a viable alternative to surgery in patients who are high-risk surgical candidates. We describe a retrospective study evaluating the results of transvaginal aspirations of benign ovarian cysts in patients at increased surgical risk, focusing on long-term follow-up for recurrence of the cyst and/or development of malignancy. Methods. Twenty-four women with ovarian cysts underwent 34 transvaginal drainages between October 1998 and December 2004. All patients were referred following diagnosis of a persistent ovarian cyst with a benign appearance on ultrasound. All patients were unsuitable candidates for surgery (history ofmore » previous pelvic surgery, n = 21; high risk for anesthesia, n = 1; and unsuitable for laparoscopy due to obesity, n = 2). Patients with a history of pregnancy, acute abdominal symptoms, or previous gynecologic malignancy were excluded. A 20G x 20 cm Chiba needle was used for transvaginal aspiration using an endocavity probe (Acuson XP, Mountain View, CA, USA; Siemens Sololine, Erlangen, Germany) and intravenous sedoanalgesia. Cysts were aspirated to dryness. Results. Long-term follow-up of patients was performed and revealed a recurrence rate of 75%. Eighty-three percent of cysts on the left and 42% of those on the right recurred. Nine of 15 (60%) patients with recurrence required further intervention. Two of 9 underwent surgical intervention only, 4 of 9 had repeat transvaginal aspiration(s) performed, and 3 of 9 had a combination of both transvaginal aspiration and surgery. No patient developed ovarian malignancy. Conclusion. Transvaginal cyst aspiration has many advantages including short hospital stay, rapid recovery, excellent patient tolerance, and a low rate of procedure-related complications. Our study demonstrates that ovarian cyst recurrence following transvaginal drainage is a more significant problem than previously documented, especially if the cyst is on the left side. However, when recurrences do occur, repeat transvaginal aspirations may be considered in the symptomatic patient.« less
Ozer, Alev; Ozer, Serdar; Kanat-Pektas, Mine
2016-05-01
The present study aims to determine how transvaginal ultrasonography and histopathological examination findings are correlated in a cohort of premenopausal and postmenopausal Turkish women with abnormal uterine bleeding. This is a retrospective review of 350 Turkish women who underwent transvaginal ultrasonography and suction curettage as a result of abnormal uterine bleeding. Sonographic appearance of the endometrium was normal in 244 patients (69.7%), while homogeneous thickening was detected in 47 patients (13.4%) and cystic thickening in 21 patients (6.0%). A sonographic diagnosis of endometrial polyp was made in 38 patients (10.9%). Histopathological analysis of endometrial samplings revealed proliferative endometrium (36%), secretory endometrium (24.6%), decidualization (10.9%), endometrial polyp (8.3%), endometritis (6.8%), endometrial hyperplasia (4.6%), irregular shedding (3.7%), atrophic endometrium (3.1%), endometrial cancer (1.1%) and placental retention (0.9%). The sonographic and histopathological findings correlated significantly (χ(2) = 122 768, P = 0.001; r = 0.215, P = 0.001). Approximately 51% of the women with homogeneous endometrial thickening had proliferative endometrium. Only 44.7% of the women with ultrasonographically visualized endometrial polyps had histopathologically diagnosed endometrial polyps. Nearly 57% of the women with cystic endometrial thickening had proliferative endometrium. If there is no facility for hysteroscopy or hysteroscopy-guided endometrial biopsy for women with abnormal uterine bleeding, transvaginal ultrasonography findings can be efficiently used to make a preliminary diagnosis and, thus, notify the pathologists. © 2016 Japan Society of Obstetrics and Gynecology.
Sonography of Methotrexate for Ectopics
NASA Astrophysics Data System (ADS)
Urzicǎ, Denise; Dorohoi, Dana-Ortansa
2007-04-01
Treatment unruptured ectopic pregnancy with methotrexate (MTX) and citrovorum factor is now an established alternative to surgical therapy. Serial measurements of serum beta-HCG and early ultrasound examination have allowed detection of early and unruptured tubal ectopic pregnancies, permitting treatment without removal of the tube. It is believed that preserving the tube increases the chance of subsequent live births. Our findings suggest that outpatient transvaginal intratubal methorexate administration can provide a safe and effective alternative to surgical treatment for patients with early and unruptured tubal ectopic pregnancy.
Antila-Långsjö, Riitta; Mäenpää, Johanna U; Huhtala, Heini; Tomás, Eija; Staff, Synnöve
2018-05-12
The aim of this study was to investigate the prevalence of post-cesarean isthmocele and to measure agreement between transvaginal ultrasonography and saline contrast sonohysterography in assessment of isthmocele. Prospective observational cohort study was carried out at Tampere University Hospital, Finland. Non-pregnant women delivered by cesarean section (n=371) were examined with transvaginal ultrasonography (TVUS) and sonohysterography (SHG) six months after cesarean section. The main outcome measure was the prevalence of isthmocele using TVUS and SHG. Secondary outcome measures were characteristics of isthmocele. Three hundred and seventy-one women were included. The prevalence of isthmocele was 22.4% based on TVUS and 45.6% based on SHG. Sensitivity and specificity for TVUS was 49.1 and 100% when compared to SHG. Therefore, half of the defects (50.9%) diagnosed with SHG remained undiagnosed with TVUS. Bland-Altman analysis showed an underestimation of 1.1 mm (range 0.00 to 7.90) for TVUS compared to SHG, with 95% limits of agreement from -1.9 to 4.1 mm. This methodological study provides confirmatory data that TVUS and SHG are not in good agreement in the isthmocele diagnostics and the use of only TVUS may lead to an underestimation of the prevalence of isthmocele. Thus, SHG should be considered as a method of choice in diagnostics of isthmocele. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Murad-Regadas, Sthela M; Regadas Filho, Francisco Sergio Pinheiro; Regadas, Francisco Sergio Pinheiro; Rodrigues, Lusmar Veras; de J R Pereira, Jacyara; da S Fernandes, Graziela Olivia; Dealcanfreitas, Iris Daiana; Mendonca Filho, Jose Jader
2014-02-01
New ultrasound techniques may complement current diagnostic tools, and combined techniques may help to overcome the limitations of individual techniques for the diagnosis of anorectal dysfunction. A high degree of agreement has been demonstrated between echodefecography (dynamic 3-dimensional anorectal ultrasonography) and conventional defecography. Our aim was to evaluate the ability of a combined approach consisting of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a 3-dimensional biplane endoprobe to assess posterior pelvic floor dysfunctions related to obstructed defecation syndrome in comparison with echodefecography. This was a prospective, observational cohort study conducted at a tertiary-care hospital. Consecutive female patients with symptoms of obstructed defecation were eligible. Each patient underwent assessment of posterior pelvic floor dysfunctions with a combination of dynamic 3-dimensional transvaginal and transrectal ultrasonography by using a biplane transducer and with echodefecography. Kappa (κ) was calculated as an index of agreement between the techniques. Diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of the combined technique in detection of posterior dysfunctions was assessed with echodefecography as the standard for comparison. A total of 33 women were evaluated. Substantial agreement was observed regarding normal relaxation and anismus. In detecting the absence or presence of rectocele, the 2 methods agreed in all cases. Near-perfect agreement was found for rectocele grade I, grade II, and grade III. Perfect agreement was found for entero/sigmoidocele, with near-perfect agreement for rectal intussusception. Using echodefecography as the standard for comparison, we found high diagnostic accuracy of transvaginal and transrectal ultrasonography in the detection of posterior dysfunctions. This combined technique should be compared with other dynamic techniques and validated with conventional defecography. Dynamic 3-dimensional transvaginal and transrectal ultrasonography is a simple and fast ultrasound technique that shows strong agreement with echodefecography and may be used as an alternative method to assess patients with obstructed defecation syndrome.
Bolotskikh, Vyacheslav; Borisova, Vera
2017-08-01
We aimed to evaluate the combined value of placental alpha microglobulin-1 (PAMG-1) and cervical length (CL) via transvaginal ultrasound for assessing risk of imminent spontaneous preterm delivery in patients presenting with threatened preterm labor (PTL). Clinical exam, PAMG-1 test, cardiotocography, and CL measurement via transvaginal ultrasound were performed on all patients meeting inclusion criteria. Ninety-nine patients at 22 +0 -36 +6 gestational weeks with the symptoms of PTL were included. The interval between sample collection and delivery was measured for each method. Performance metrics were calculated for PAMG-1 test, CL < 25 mm, and contractions ≥ 8/h. The sensitivity, specificity, positive predictive value, and negative predictive value for the PAMG-1 test were 100%, 95%, 75%, 100% and 100%, 98%, 88%, 100% for 7 and 14 days, respectively; the respective values for CL < 25 mm were 83%, 59%, 22%, 96% and 79%, 59%, 24%, 94% for 7 and 14 days; and those for contractions ≥ 8/h were 42%, 38%, 8%, 83% and 43%, 38%, 10%, 80% for 7 and 14 days. Specificity for the PAMG-1 test was statistically significant (P < 0.001) in pairwise comparisons for all other methods. Patients were divided into four groups for analysis of PAMG-1 test performance as follows: CL < 15 mm (100%, 100%, 100%, 100% and 100%, 100%, 100%, 100% for 7 and 14 days, respectively); CL < 25 mm (100%, 94%, 83%, 100% and 100%, 97%, 92%, 100% for 7 and 14 days, respectively); CL of 15-30 mm (100%, 95%, 64%, 100% and 100%, 97%, 82%, 100% for 7 and 14 days, respectively); and CL ≥ 30 mm (100%, 100%, 100%, 100% and 100%, 100%, 100%, 100% for 7 and 14 days, respectively). The use of the PAMG-1 test in patients with a CL of 15-30 mm is highly predictive of imminent spontaneous preterm delivery in women presenting with threatened PTL and could save hospital resources. © 2017 The Authors. Journal of Obstetrics and Gynaecology Research published by John Wiley & Sons Australia, Ltd on behalf of Japan Society of Obstetrics and Gynecology.
NASA Astrophysics Data System (ADS)
Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron
2017-03-01
Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.
NASA Astrophysics Data System (ADS)
Kumavor, Patrick D.; Alqasemi, Umar; Tavakoli, Behnoosh; Li, Hai; Yang, Yi; Zhu, Quing
2013-03-01
This paper presents a real-time transvaginal photoacoustic imaging probe for imaging human ovaries in vivo. The probe consists of a high-throughput (up to 80%) fiber-optic 1 x 19 beamsplitters, a commercial array ultrasound transducer, and a fiber protective sheath. The beamsplitter has a 940-micron core diameter input fiber and 240-micron core diameter output fibers numbering 36. The 36 small-core output fibers surround the ultrasound transducer and delivers light to the tissue during imaging. A protective sheath, modeled in the form of the transducer using a 3-D printer, encloses the transducer with array of fibers. A real-time image acquisition system collects and processes the photoacoustic RF signals from the transducer, and displays the images formed on a monitor in real time. Additionally, the system is capable of coregistered pulse-echo ultrasound imaging. In this way, we obtain both morphological and functional information from the ovarian tissue. Photoacousitc images of malignant human ovaries taken ex vivo with the probe revealed blood vascular and networks that was distinguishable from normal ovaries, making the probe potential useful for characterizing ovarian tissue.
Epstein, E; Van Calster, B; Timmerman, D; Nikman, S
2016-01-01
To compare subjective ultrasound assessment and the ADNEX model with ultrasound-guided tru-cut biopsy to differentiate disseminated primary ovarian cancer from metastatic non-ovarian cancer. This was a prospective study including 143 consecutive women with disseminated malignancy of unknown primary origin, with a pelvic tumor/carcinosis. Women underwent either transvaginal or transrectal ultrasound as well as transabdominal ultrasound examination followed by tru-cut biopsy. The ultrasound examiner assessed tumor morphology, spread in the pelvis and abdomen, and predicted tumor origin as primary ovarian or metastatic using both subjective assessment and the ADNEX model. Histology from tru-cut biopsy served as the gold standard for assessment of diagnostic accuracy. Biopsy adequacy and the complication rate were assessed. Tru-cut biopsy was performed transvaginally in 131/143 (92%) women. Two women needed inpatient care (one had abdominal wall hematoma, and one infection). Biopsy resulted in a conclusive diagnosis in 126/143 (88%) women, amongst whom cytoreductive surgery was performed in 30/126 confirming the diagnosis in all cases. Non-ovarian metastatic cancer was found in 37/126 (29%) women and primary ovarian cancer in 89/126 (71%) women. Subjective ultrasound evaluation had a sensitivity of 82% (73/89) and a specificity of 70% (26/37) in predicting primary ovarian cancer. The ADNEX model had an area under the receiver-operating characteristics curve of 0.891 (95% CI, 0.794-0.946) (in women with an ovarian lesion, n = 104). Tumor origin was associated with age, CA 125, previous neoplasia, presence of omental cake and tumor mobility. Subjective ultrasound assessment and the ADNEX model can both be used to predict whether a pelvic tumor is metastatic and of non-ovarian origin, indicating the need for tru-cut biopsy, which is associated with very few complications and will provide a conclusive diagnosis in nine out of 10 women. Copyright © 2015 ISUOG. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Bhandari, Harish; Agrawal, Rina; Weissman, Ariel; Shoham, Gon; Leong, Milton; Shoham, Zeev
2015-12-01
The objective of this study was to identify clinical practices worldwide, which would help in recognizing women at risk of excessive bleeding or of developing pelvic infection following trans-vaginal ovum pick-up (TV-OPU), measures taken to minimize risks and their management. A prospective, web-based questionnaire with distinct questions related to the practice of TV-OPU. A total of 155 units from 55 countries performing 97,200 IVF cycles annually responded to this web-based survey. A majority (65 %) responded that they would routinely carry out full blood count, while 35 % performed coagulation profile. Less than a third agreed screening women for vaginal infections. About a third used both sterile water and antiseptic to minimize ascending infection, and 52 % used antibiotics for prophylaxis. Doppler ultrasound was routinely used by 20 % of clinicians. 73 % of the clinicians preferred conservative management as their first line management for patients diagnosed with intra-abdominal bleeding. The study has identified a wide variation in the practices of minimizing infection and bleeding complications. The dearth of good quality evidence may be responsible for the lack of published guidelines, and therefore a lack of consensus on the optimum practice for minimizing the risk of infection and bleeding during TV-OPU.
Buhling, Kai J; Lezon, S; Eulenburg, C; Schmalfeldt, B
2017-05-01
The purpose of this study was to systematically analyze the effect of transvaginal ultrasonography in an asymptomatic female population as an annual screening procedure with regard to mortality data. Studies were evaluated descriptively on their strengths and weaknesses considering the methods and results. We evaluated 632 international studies by selecting only randomized controlled trials (RCTs). Three RCTs concerning transvaginal ultrasonography were found, performed in Japan, the USA, and Great Britain. Currently, no clear recommendation for the screening for ovarian cancer in an asymptomatic population can be given based on these three studies. The authors could not show a change in mortality using transvaginal ultrasonography for annual screening. An annual palpation does not offer a beneficial effect. The development of new ultrasound machines with higher image resolution in combination with a well-standardized algorithm for ovarian cancer in upcoming years might provide an improvement regarding mortality. The current studies do not show a benefit in screening an asymptomatic population annually with transvaginal ultrasonography, but the most recent publication showed a trend toward lower mortality in patients who underwent screening after 7-14 years of follow-up. Nevertheless, all three heterogeneous RCTs had weaknesses in their methods and therefore they neither contradict the general recommendation for screening in an asymptomatic population nor do they support it.
Buys, Saundra S; Partridge, Edward; Black, Amanda; Johnson, Christine C; Lamerato, Lois; Isaacs, Claudine; Reding, Douglas J; Greenlee, Robert T; Yokochi, Lance A; Kessel, Bruce; Crawford, E David; Church, Timothy R; Andriole, Gerald L; Weissfeld, Joel L; Fouad, Mona N; Chia, David; O'Brien, Barbara; Ragard, Lawrence R; Clapp, Jonathan D; Rathmell, Joshua M; Riley, Thomas L; Hartge, Patricia; Pinsky, Paul F; Zhu, Claire S; Izmirlian, Grant; Kramer, Barnett S; Miller, Anthony B; Xu, Jian-Lun; Prorok, Philip C; Gohagan, John K; Berg, Christine D
2011-06-08
Screening for ovarian cancer with cancer antigen 125 (CA-125) and transvaginal ultrasound has an unknown effect on mortality. To evaluate the effect of screening for ovarian cancer on mortality in the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Trial. Randomized controlled trial of 78,216 women aged 55 to 74 years assigned to undergo either annual screening (n = 39,105) or usual care (n = 39,111) at 10 screening centers across the United States between November 1993 and July 2001. Intervention The intervention group was offered annual screening with CA-125 for 6 years and transvaginal ultrasound for 4 years. Participants and their health care practitioners received the screening test results and managed evaluation of abnormal results. The usual care group was not offered annual screening with CA-125 for 6 years or transvaginal ultrasound but received their usual medical care. Participants were followed up for a maximum of 13 years (median [range], 12.4 years [10.9-13.0 years]) for cancer diagnoses and death until February 28, 2010. Mortality from ovarian cancer, including primary peritoneal and fallopian tube cancers. Secondary outcomes included ovarian cancer incidence and complications associated with screening examinations and diagnostic procedures. Ovarian cancer was diagnosed in 212 women (5.7 per 10,000 person-years) in the intervention group and 176 (4.7 per 10,000 person-years) in the usual care group (rate ratio [RR], 1.21; 95% confidence interval [CI], 0.99-1.48). There were 118 deaths caused by ovarian cancer (3.1 per 10,000 person-years) in the intervention group and 100 deaths (2.6 per 10,000 person-years) in the usual care group (mortality RR, 1.18; 95% CI, 0.82-1.71). Of 3285 women with false-positive results, 1080 underwent surgical follow-up; of whom, 163 women experienced at least 1 serious complication (15%). There were 2924 deaths due to other causes (excluding ovarian, colorectal, and lung cancer) (76.6 per 10,000 person-years) in the intervention group and 2914 deaths (76.2 per 10,000 person-years) in the usual care group (RR, 1.01; 95% CI, 0.96-1.06). Among women in the general US population, simultaneous screening with CA-125 and transvaginal ultrasound compared with usual care did not reduce ovarian cancer mortality. Diagnostic evaluation following a false-positive screening test result was associated with complications. Trial Registration clinicaltrials.gov Identifier: NCT00002540.
Lu, Karen H; Loose, David S; Yates, Melinda S; Nogueras-Gonzalez, Graciela M; Munsell, Mark F; Chen, Lee-May; Lynch, Henry; Cornelison, Terri; Boyd-Rogers, Stephanie; Rubin, Mary; Daniels, Molly S; Conrad, Peggy; Milbourne, Andrea; Gershenson, David M; Broaddus, Russell R
2013-08-01
Women with Lynch syndrome have a 40% to 60% lifetime risk for developing endometrial cancer, a cancer associated with estrogen imbalance. The molecular basis for endometrial-specific tumorigenesis is unclear. Progestins inhibit estrogen-driven proliferation, and epidemiologic studies have shown that progestin-containing oral contraceptives (OCP) reduce the risk of endometrial cancer by 50% in women at general population risk. It is unknown whether they are effective in women with Lynch syndrome. Asymptomatic women ages 25 to 50 with Lynch syndrome were randomized to receive the progestin compounds Depo-Provera (depo-MPA) or OCP for three months. An endometrial biopsy and transvaginal ultrasound were conducted before and after treatment. Endometrial proliferation was evaluated as the primary endpoint. Histology and a panel of surrogate endpoint biomarkers were evaluated for each endometrial biopsy as secondary endpoints. A total of 51 women were enrolled, and 46 completed treatment. Two of the 51 women had complex hyperplasia with atypia at the baseline endometrial biopsy and were excluded from the study. Overall, both depo-MPA and OCP induced a dramatic decrease in endometrial epithelial proliferation and microscopic changes in the endometrium characteristic of progestin action. Transvaginal ultrasound measurement of endometrial stripe was not a useful measure of endometrial response or baseline hyperplasia. These results show that women with Lynch syndrome do show an endometrial response to short-term exogenous progestins, suggesting that OCP and depo-MPA may be reasonable chemopreventive agents in this high-risk patient population.
Lu, Karen H.; Loose, David S.; Yates, Melinda S.; Nogueras-Gonzalez, Graciela M.; Munsell, Mark F.; Chen, Lee-may; Lynch, Henry; Cornelison, Terri; Boyd-Rogers, Stephanie; Rubin, Mary; Daniels, Molly S.; Conrad, Peggy; Milbourne, Andrea; Gershenson, David M.; Broaddus, Russell R.
2013-01-01
Women with Lynch syndrome have a 40–60% lifetime risk for developing endometrial cancer, a cancer associated with estrogen imbalance. The molecular basis for endometrial-specific tumorigenesis is unclear. Progestins inhibit estrogen-driven proliferation, and epidemiologic studies have demonstrated that progestin-containing oral contraceptives (OCP) reduce the risk of endometrial cancer by 50% in women at general population risk. It is unknown if they are effective in women with Lynch syndrome. Asymptomatic women age 25–50 with Lynch syndrome were randomized to receive the progestin compounds depo-Provera (depoMPA) or OCP for three months. An endometrial biopsy and transvaginal ultrasound were performed before and after treatment. Endometrial proliferation was evaluated as the primary endpoint. Histology and a panel of surrogate endpoint biomarkers were evaluated for each endometrial biopsy as secondary endpoints. A total of 51 women were enrolled, and 46 completed treatment. Two of the 51 women had complex hyperplasia with atypia at the baseline endometrial biopsy and were excluded from the study. Overall, both depoMPA and OCP induced a dramatic decrease in endometrial epithelial proliferation and microscopic changes in the endometrium characteristic of progestin action. Transvaginal ultrasound measurement of endometrial stripe was not a useful measure of endometrial response or baseline hyperplasia. These results demonstrate that women with Lynch syndrome do show an endometrial response to short term exogenous progestins, suggesting that OCP and depoMPA may be reasonable chemopreventive agents in this high-risk patient population. PMID:23639481
Dickey, R P; Gasser, R F; Olar, T T; Curole, D N; Taylor, S N; Matulich, E M; West, J D; Tsien, F
1994-02-01
The objective of this study was to determine if measurement of initial crown--rump length (CRL) is helpful in predicting low birth weight, newborn length, spontaneous abortions, or abortus karyotype. We measured CRL prospectively in 837 consecutive singleton pregnancies at the time a heart rate was first detectable with transvaginal ultrasonography and compared these measurements to normal values for the 10th through 90th centiles determined from 227 transvaginal ultrasound measurements in in-vitro fertilization and gamete intra-Fallopian transfer pregnancies with known ovulation dates. The relationship of initial CRL to birth weight and length and to abortion and abortus karyotype was analysed after all pregnancies had delivered. Initial CRL measured after the 28th post-ovulation day was predictive of subsequent abortion, but not of low birth weight or length. The abortion rate was 3.3% [95% confidence interval (CI) 1.5%, 5.1%] when initial CRL > or = 50th centile, compared to 19.4% (95% CI 15.4%, 23.4%) when < 50th centile. Initial CRL was < 50th centile in 13 out of 14 trisomic and in eight out of 10 other karyotypically abnormal aborti. These results indicate that initial CRL measured after the 28th post-ovulation day may help to identify pregnancies at increased risk of abortion due to abnormal karyotypes.
Endometriosis on the uterosacral ligament: a marker of ureteral involvement.
Lima, Raquel; Abdalla-Ribeiro, Helizabet; Nicola, Ana Luisa; Eras, Aline; Lobao, Anna; Ribeiro, Paulo Ayroza
2017-06-01
To evaluate the association between ultrasound measurements of endometriosis nodules on the uterosacral ligament (USL) and the risk of ureteral involvement, as well as to assess whether associations with other ultrasound variables increase the sensitivity and specificity of the diagnosis of ureteral endometriosis. Cross-sectional, observational study. University hospital. Four hundred sixty-three women with deep infiltrating endometriosis (DIE). Patients diagnosed with DIE underwent transvaginal ultrasound endometriosis mapping before laparoscopic surgery for full excision of endometriotic lesions. Preoperative ultrasound evaluation, intra- and postoperative assessment, and anatomopathologic confirmation. Of the 463 patients who participated in the study, 111 (23.97%) presented with endometriosis nodules with USL involvement on ultrasound examination conducted by a single radiologist. Receiver operating characteristic curve analysis showed that the size of the USL nodule had a statistically significant association with ipsilateral ureteral involvement. After multivariate logistic regression, the variables reduction in ovarian mobility, ureteral changes on the right side, size of the USL nodule, and presence of endometrioma on the left side were significantly associated with a ureteral endometriosis nodule. However, the combined result for the variables cited was worse than the diagnostic analysis using only the size of the USL nodule. Uterosacral ligament nodules with ultrasound measurements of 1.75 cm and 1.95 cm on the right and left sides, respectively, significantly increase the risk of ureteral involvement. Even with the association of other ultrasound variables, there was no improvement in sensitivity. Therefore, USL nodule size is a key measure for therapeutic planning and consent of the patient. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène
2016-10-15
Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.
Pregnancy loss: French clinical practice guidelines.
Huchon, C; Deffieux, X; Beucher, G; Capmas, P; Carcopino, X; Costedoat-Chalumeau, N; Delabaere, A; Gallot, V; Iraola, E; Lavoue, V; Legendre, G; Lejeune-Saada, V; Leveque, J; Nedellec, S; Nizard, J; Quibel, T; Subtil, D; Vialard, F; Lemery, D
2016-06-01
In intrauterine pregnancies of uncertain viability with a gestational sac without a yolk sac (with a mean of three orthogonal transvaginal ultrasound measurements <25mm), the suspected pregnancy loss should only be confirmed after a follow-up scan at least 14 days later shows no embryo with cardiac activity (Grade C). In intrauterine pregnancies of uncertain viability with an embryo <7mm on transvaginal ultrasound, the suspected pregnancy loss should only be confirmed after a follow-up scan at least 7 days later (Grade C). In pregnancies of unknown location after transvaginal ultrasound (i.e. not visible in the uterus), a threshold of at least 3510IU/l for the serum human chorionic gonadotrophin assay is recommended; above that level, a viable intrauterine pregnancy can be ruled out (Grade C). Postponing conception after an early miscarriage in women who want a new pregnancy is not recommended (Grade A). A work-up for women with recurrent pregnancy loss should include the following: diabetes (Grade A), antiphospholipid syndrome (Grade A), hypothyroidism with anti-thyroid peroxidase (anti-TPO) and anti-thyroglobulin (anti-Tg) antibodies (Grade A), vitamin deficiencies (B9, B12) (Grade C), hyperhomocysteinaemia (Grade C), hyperprolactinaemia (Grade B), diminished ovarian reserve (Grade C), and a uterine malformation or an acquired uterine abnormality amenable to surgical treatment (Grade C). The treatment options recommended for women with a missed early miscarriage are vacuum aspiration (Grade A) or misoprostol (Grade B); and the treatment options recommended for women with an incomplete early miscarriage are vacuum aspiration (Grade A) or expectant management (Grade A). In the absence of both chorioamnionitis and rupture of the membranes, women with a threatened late miscarriage and an open cervix, with or without protrusion of the amniotic sac into the vagina, should receive McDonald cerclage, tocolysis with indomethacin, and antibiotics (Grade C). Among women with a threatened late miscarriage and an isolated undilated shortened cervix (<25mm on ultrasound), cerclage is only indicated for those with a history of either late miscarriage or preterm delivery (Grade A). Among women with a threatened late miscarriage, an isolated undilated shortened cervix (<25mm on ultrasound) and no uterine contractions, daily treatment with vaginal progesterone up to 34 weeks of gestation is recommended (Grade A). Hysteroscopic section of the septum is recommended for women with a uterine septum and a history of late miscarriage (Grade C). Correction of acquired abnormalities of the uterine cavity (e.g. polyps, myomas, synechiae) is recommended after three early or late miscarriages (Grade C). Prophylactic cerclage is recommended for women with a history of three late miscarriages or preterm deliveries (Grade B). Low-dose aspirin and low-molecular-weight heparin at a preventive dose are recommended for women with obstetric antiphospholipid syndrome (Grade A). Glycaemic levels should be controlled before conception in women with diabetes (Grade A). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Edris, Fawaz E
2014-10-01
To assess the reliability of trans-vaginal-scan (TVS) in measuring the uterine depth (UD) in comparison with ultrasound-guided trial-transfer (UTT). This prospective study was conducted in 66 consecutive patients undergoing in-vitro fertilization and embryo transfer (IVF-ET). The study took place in a private IVF center in Jeddah, Saudi Arabia between November 2013 and January 2014. The patients underwent UD measurements using TVS and UTT, sequentially. All scans were performed by a single sonographer, and all UTT were carried out by a single physician who was blinded to the TVS measurement. The median (95% confidence interval) UD measurement using the TVS method was 6.9 cm (5.0-12.5) and UTT was 7.1 cm (5.9-13.5), (p<0.0001). Fifteen patients (22.7%) had a difference of >1 cm between the 2 measurement modalities (group-B). When measured by UTT, 93.3% of patients in group-B had UD >/-8cm, compared with 9.8% of patients in group-A, (p<0.0001). Group-B had a significantly longer uterine cavity when measured by UTT (p<0.0001), and a trend towards significance when measured by TVS (p=0.055). The TVS measurements generally underestimated UD when compared with UTT. Trans-vaginal-scan is less reliable than UTT and should not be used as a substitute. Larger sample-size studies involving different personnel, and equipment is needed.
[Tamoxifen and endometrial disease in patients with breast cancer].
Dalbert, Delia B; Rodríguez de la Peña, Margarita M; Figueredo, Alicia; Mural, Juan; Bartt, Ofelia; Subiela, Ramiro; Rossi, Carlos; Bazán, Graciela
2013-01-01
The objectives were to evaluate prevalence of endometrial disease in patients treated with tamoxifen (TAM) and analyze the epidemiological, sonographic, hysteroscopic and histopathological findings. From January 1999 to December 2008, 152 breast cancer patients treated with TAM (20 mg/day), symptomatic (with bleeding) or asymptomatic, pre-and postmenopausal, were included consecutively in a prospective and observational follow-up study. Diagnostic methods were (TV) transvaginal ultrasound, hysteroscopy and curettage biopsy. TV ultrasound was performed every 12 months for 12 to 60 months. The patients' age were 62.76 years ± 10.24 the TAM-time: 36.24 ± 19. Adenocarcinoma was observed in 3/87 patients (3.45%) with risk factors and in 1/65 (1.54%) without them (RA 1.91, IC 95% 1.88-1.94). We found benign disease in 148 patients (97.37%) and adenocarcinomas in 4 (2.63%), one within a polyp. The 4 adenocarcinomas were detected in postmenopausal women (2 asymptomatic) with endometrial thicknesses equal or greater than 16 mm. The cancer risk was significantly increased in symptomatic (2.36 versus 0.42 in asymptomatic). Three adenocarcinomas were observed between 24 and 48 months of treatment. In conclusion, we suggest an adequate transvaginal ultrasound monitoring of asymptomatic patients treated with TAM, with removal of polyps, because atypia can be present hidden within, considering risk factors and exposure time. We suggest as an acceptable cut-off = 10 mm in asymptomatic postmenopausal patients.
Dueholm, Margit; Hjorth, Ina Marie D
2017-04-01
The aim in the diagnosis of abnormal uterine bleeding (AUB) is to identify the bleeding cause, which can be classified by the PALM-COEIN (Polyp, Adenomyosis, Leiomyoma, Malignancy (and hyperplasia), Coagulopathy, Ovulatory disorders, Endometrial, Iatrogenic and Not otherwise classified) classification system. In a gynecologic setting, the first step is most often to identify structural abnormalities (PALM causes). Common diagnostic options for the identification of the PALM include ultrasonography, endometrial sampling, and hysteroscopy. These options alone or in combination are sufficient for the diagnosis of most women with AUB. Contrast sonography with saline or gel infusion, three-dimensional ultrasonography, and magnetic resonance imaging may be included. The aim of this article is to describe how a simple structured transvaginal ultrasound can be performed and implemented in the common gynecologic practice to simplify the diagnosis of AUB and determine when additional invasive investigations are required. Structured transvaginal ultrasound for the identification of the most common endometrial and myometrial abnormalities and the most common ultrasound features are described. Moreover, situations where magnetic resonance imaging may be included are described. This article proposes a diagnostic setup in premenopausal women for the classification of AUB according to the PALM-COEIN system. Moreover, a future diagnostic setup for fast-track identification of endometrial cancer in postmenopausal women based on a structured evaluation of the endometrium is described. Copyright © 2016. Published by Elsevier Ltd.
M'Zali, Fatima; Bounizra, Carole; Leroy, Sandrine; Mekki, Yahia; Quentin-Noury, Claudine; Kann, Michael
2014-01-01
Aim of the Study In many countries, Low Level Disinfection (LLD) of covered transvaginal ultrasound probes is recommended between patients' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms. Materials and Methods Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV) was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods. Results A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe); Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe). No fungi were isolated. Conclusion Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing the disinfection procedure. PMID:24695371
Cesarean Delivery Changes the Natural Position of the Uterus on Transvaginal Ultrasonography.
Kaelin Agten, Andrea; Honart, Anne; Monteagudo, Ana; McClelland, Spencer; Basher, Basmy; Timor-Tritsch, Ilan E
2018-05-01
To assess whether cesarean delivery changes the natural position of the uterus. In this retrospective Institutional Review Board-approved cohort study, we conducted a search of our university gynecologic ultrasonography (US) database. Patients with transvaginal US images before and after either vaginal or cesarean delivery between 2012 and 2015 were included. Women with prior cesarean delivery were excluded. Two readers independently measured antepartum and postpartum flexion angles between the longitudinal axis of the uterine body and the cervix. We calculated intraclass correlation coefficients to measure inter-reader agreement. Antepartum and postpartum uterine flexion angles were compared between patients with vaginal and cesarean delivery. We included 173 patients (107 vaginal and 66 cesarean delivery). The mean interval between scans ± SD was 18 ± 10 months. Inter-reader agreement for flexion angles was almost perfect (intraclass correlation coefficients: antepartum, 0.939; postpartum, 0.969; both P < .001). There was no difference in mean antepartum flexion angles for cesarean delivery (154.8° ± 45.7°) versus vaginal delivery (145.8° ± 43.7°; P = .216). Mean postpartum flexion angles were higher after cesarean delivery (180.4° ± 51.2°) versus vaginal delivery (152.8° ± 47.7°; P = .001. Differences in antepartum and postpartum flexion angles between cesarean and vaginal delivery were statistically significant (25.6° versus 7.0°; P = .027). Cesarean delivery can change the uterine flexion angle to a more retroflexed position. Therefore, all women with a history of cesarean delivery should undergo a transvaginal US examination before any gynecologic surgery or intrauterine device placement to reduce the possibility of surgical complications. © 2017 by the American Institute of Ultrasound in Medicine.
De Smet, F; De Brabanter, J; Van den Bosch, T; Pochet, N; Amant, F; Van Holsbeke, C; Moerman, P; De Moor, B; Vergote, I; Timmerman, D
2006-06-01
Preoperative knowledge of the depth of myometrial infiltration is important in patients with endometrial carcinoma. This study aimed at assessing the value of histopathological parameters obtained from an endometrial biopsy (Pipelle de Cornier; results available preoperatively) and ultrasound measurements obtained after transvaginal sonography with color Doppler imaging in the preoperative prediction of the depth of myometrial invasion, as determined by the final histopathological examination of the hysterectomy specimen (the gold standard). We first collected ultrasound and histopathological data from 97 consecutive women with endometrial carcinoma and divided them into two groups according to surgical stage (Stages Ia and Ib vs. Stages Ic and higher). The areas (AUC) under the receiver-operating characteristics curves of the subjective assessment of depth of invasion by an experienced gynecologist and of the individual ultrasound parameters were calculated. Subsequently, we used these variables to train a logistic regression model and least squares support vector machines (LS-SVM) with linear and RBF (radial basis function) kernels. Finally, these models were validated prospectively on data from 76 new patients in order to make a preoperative prediction of the depth of invasion. Of all ultrasound parameters, the ratio of the endometrial and uterine volumes had the largest AUC (78%), while that of the subjective assessment was 79%. The AUCs of the blood flow indices were low (range, 51-64%). Stepwise logistic regression selected the degree of differentiation, the number of fibroids, the endometrial thickness and the volume of the tumor. Compared with the AUC of the subjective assessment (72%), prospective evaluation of the mathematical models resulted in a higher AUC for the LS-SVM model with an RBF kernel (77%), but this difference was not significant. Single morphological parameters do not improve the predictive power when compared with the subjective assessment of depth of myometrial invasion of endometrial cancer, and blood flow indices do not contribute to the prediction of stage. In this study an LS-SVM model with an RBF kernel gave the best prediction; while this might be more reliable than subjective assessment, confirmation by larger prospective studies is required. Copyright 2006 ISUOG. Published by John Wiley & Sons, Ltd.
Efficacy of first-trimester ultrasound parameters for prediction of early spontaneous abortion.
Datta, Mamta Rath; Raut, Ankush
2017-09-01
To assess first-trimester ultrasound measurements for the prediction of early spontaneous abortion. In a prospective observational study in Jamshedpur, India, women with singleton pregnancies of 42-76 days were enrolled between November 2014 and April 2016. Inclusion criteria were spontaneous conception, embryonic cardiac activity, and regular menstrual cycle. Fetal crown-to-rump length (CRL), gestational sac diameter (GSD), yolk sac diameter (YSD), and fetal heart rate (FHR) were measured by transvaginal ultrasonography. Ultrasonography was repeated at 12 weeks and beyond to determine pregnancy continuation. Among 800 women, 140 (17.5%) experienced early spontaneous abortion. CRL, GSD, and FHR values below the 5th percentile (odds ratio [OR] 26.48, 26.94, and 100.63, respectively), and YSD above the 95th percentile (OR 1.04) were predictors of early abortion. Normal YSD did not reduce the risk of abortion if the other three parameters were below the 5th percentile (OR 34.27). For every 10-bpm decrease in FHR below 130, there was 26.7% increased risk of abortion. GSD-CRL difference of less than 5 mm was associated with a higher likelihood of abortion (OR 4.88). First-trimester ultrasound measurements are predictors of early abortion. Risk assessment tables based on combinations of abnormal measures might improve prediction rates. © 2017 International Federation of Gynecology and Obstetrics.
Hasegawa, Junichi; Kawabata, Ikuno; Takeda, Yoshiharu; Aoki, Hiroaki; Fukami, Takehiko; Tajima, Atsushi; Miyakoshi, Kei; Otsuki, Katsufumi; Shinozuka, Norio; Matsuda, Yoshio; Iwashita, Mitsutoshi; Okai, Takashi; Nakai, Akihito
2017-01-01
To clarify whether distinguishing between the uterine isthmus and cervix can improve the accuracy of diagnosing placenta previa at term. A multicenter prospective observational study was conducted among pregnant women with suspected placenta previa at 20-24 weeks' gestation. Subjects were divided into the open isthmus group and closed isthmus group. The accuracy of diagnosing placenta previa at term was compared between the 2 groups. We screened 9,341 patients, and 53 (0.6%) met the inclusion criteria. Nineteen cases with an open isthmus and 34 with a closed isthmus were followed. The accuracy for diagnosing placenta previa or a low-lying placenta at term was 94.7% in the open isthmus group and 26.5% in the closed isthmus group (p < 0.001). Elective or emergency Cesarean section was required in 100% of cases in the open isthmus group and 20.6% in the closed isthmus group (p < 0.001). A high prediction rate of placenta previa was obtained by using transvaginal ultrasound at 20-24 weeks' gestation after the isthmus opened by carefully distinguishing between the cervix and isthmus. © 2016 S. Karger AG, Basel.
Dasgupta, Subhankar; Dasgupta, Shyamal; Sharma, Partha Pratim; Mukherjee, Amitabha; Ghosh, Tarun Kumar
2011-11-01
To investigate the effect of oral progesterone on the accuracy of imaging studies performed to detect endometrial pathology in comparison to hysteroscopy-guided biopsy in perimenopausal women on progesterone treatment for abnormal uterine bleeding. The study population comprised of women aged 40-55 years with complaints of abnormal uterine bleeding who were also undergoing oral progesterone therapy. Women with a uterus ≥ 12 weeks' gestation size, previous abnormal endometrial biopsy, cervical lesion on speculum examination, abnormal Pap smear, active pelvic infection, adnexal mass on clinical examination or during ultrasound scan and a positive pregnancy test were excluded. A transvaginal ultrasound followed by saline infusion sonography were done. On the following day, a hysteroscopy followed by a guided biopsy of the endometrium or any endometrial lesion was performed. Comparison between the results of the imaging study with the hysteroscopy and guided biopsy was done. The final analysis included 83 patients. For detection of overall pathology, polyp and fibroid transvaginal ultrasound had a positive likelihood ratio of 1.65, 5.45 and 5.4, respectively, and a negative likelihood ratio of 0.47, 0.6 and 0.43, respectively. For detection of overall pathology, polyp and fibroid saline infusion sonography had a positive likelihood ratio of 4.4, 5.35 and 11.8, respectively, and a negative likelihood ratio of 0.3, 0.2 and 0.15, respectively. In perimenopausal women on oral progesterone therapy for abnormal uterine bleeding, imaging studies cannot be considered as an accurate method for diagnosing endometrial pathology when compared to hysteroscopy and guided biopsy. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.
The volume of the cerebellum in the second semester of gestation.
Vulturar, Damiana; Fărcăşanu, Alexandru; Turcu, Flaviu; Boitor, Dan; Crivii, Carmen
2018-01-01
The cerebellum ("little brain"), the largest part of hind brain, lies in the posterior cranial fossa, beneath the occipital lobe and dorsal to the brainstem. It develops over a long period: it is one of the first structures in the brain to begin to differentiate, but one of the last to mature. The use of ultrasonography has significantly improved the evaluation of fetal growth and development and has permitted prenatal diagnosis of a variety of congenital malformations.The aim of our study was to evaluate the cerebellar growth and development using 2 different measuring techniques: microMRI and ultrasound technique. The cerebellum measurements were related to gestational age. We used 14 human fetuses corresponding to 15-28 gestational weeks, immersed in a 9% formalin solution. Magnetic Resonance Imaging (MRI) was performed by employing a Bruker BioSpec 70/16USR scanner (Bruker BioSpin MRI GmbH, Ettlingen, Germany), operated at 7.04 Tesla for cerebellar volume measurement. Ultrasonographic measurements of the cerebellum diameter were performed on 14 pregnant women, 15 - 28 gestational weeks. Ultrasound scan used 5-10 MHZ for transvaginal approach. Taking into consideration the values of the cerebellum dimensions and considering the general shape of the cerebellum as a transverse ellipsoid, the volume of the cerebellum was calculated by a mathematical formula for ellipsoid volume. The study correlates the measurements from the microMRI study with the ultrasounds data and the results are superposable. Both established the exponential volume growth after the 22-23 GW. We used the ellipsoid volume formula for the cerebellar volume using the half of the three diameters of the cerebellum determined by ultrasound measurements:Cerebellar Volume = Ellipsoid volume = 3/4 π r1 r2 r3. There is a linear correlation between the microMRI measurements and ultrasound determinations. Based on all collected data we could apply an easy formula to calculate the volume of cerebellum, a useful criterion in the evaluation of the cerebellar development and the appreciation of the gestational age.
[Rudimentary horn pregnancy diagnostic: difficulties and therapeutic management].
Mamouni, Nisrine; Ghazal, Nabil; Erraghay, Sanaa; Bouchikhi, Chahrazed; Banani, Abdelaziz
2016-01-01
The occurrence of rudimentary horn pregnancy is an extremely rare and potentially serious obstetric entity, threatening maternal and fetal outcome. The authors report five cases of rudimentary horn pregnancy, the difficulties in making a proper diagnosis and the therapeutic management of this pathological entity, stressing the importance of transvaginal ultrasound, of pelvic MRI and laparoscopy in the early diagnosis of this type of uterine malformation.
Irregular or absent periods--what can an ultrasound scan tell you?
Khalid, Asma
2004-02-01
Transvaginal ultrasonography has increased our appreciation of the physiological changes in the ovary and endometrium that occur during the normal menstrual cycle. It has become a primary investigative tool in women with irregular or absent periods. Its usefulness in cases of primary amenorrhoea to assess anatomy is also undisputed although it may have limitations in terms of its specificity. However, the interpretation of ultrasound images in women with irregular menses or secondary amenorrhoea is not entirely straightforward. This is particularly true in the diagnosis of polycystic ovary syndrome, a condition of uncertain aetiology, which may present with oligoamenorrhoea. This chapter aims to discuss the benefits and limitations of ultrasound while taking into account the broad overlap between normal and abnormal physiology, some of which has still to be elucidated.
The effect of dyad versus individual simulation-based ultrasound training on skills transfer.
Tolsgaard, Martin G; Madsen, Mette E; Ringsted, Charlotte; Oxlund, Birgitte S; Oldenburg, Anna; Sorensen, Jette L; Ottesen, Bent; Tabor, Ann
2015-03-01
Dyad practice may be as effective as individual practice during clinical skills training, improve students' confidence, and reduce costs of training. However, there is little evidence that dyad training is non-inferior to single-student practice in terms of skills transfer. This study was conducted to compare the effectiveness of simulation-based ultrasound training in pairs (dyad practice) with that of training alone (single-student practice) on skills transfer. In a non-inferiority trial, 30 ultrasound novices were randomised to dyad (n = 16) or single-student (n = 14) practice. All participants completed a 2-hour training programme on a transvaginal ultrasound simulator. Participants in the dyad group practised together and took turns as the active practitioner, whereas participants in the single group practised alone. Performance improvements were evaluated through pre-, post- and transfer tests. The transfer test involved the assessment of a transvaginal ultrasound scan by one of two clinicians using the Objective Structured Assessment of Ultrasound Skills (OSAUS). Thirty participants completed the simulation-based training and 24 of these completed the transfer test. Dyad training was found to be non-inferior to single-student training: transfer test OSAUS scores were significantly higher than the pre-specified non-inferiority margin (delta score 7.8%, 95% confidence interval -3.8-19.6%; p = 0.04). More dyad (71.4%) than single (30.0%) trainees achieved OSAUS scores above a pre-established pass/fail level in the transfer test (p = 0.05). There were significant differences in performance scores before and after training in both groups (pre- versus post-test, p < 0.01) with large effect sizes (Cohen's d = 3.85) and no significant interactions between training type and performance (p = 0.59). The dyad group demonstrated higher training efficiency in terms of simulator score per number of attempts compared with the single-student group (p = 0.03). Dyad practice improves the efficiency of simulation-based training and is non-inferior to individual practice in terms of skills transfer. © 2015 John Wiley & Sons Ltd.
Transvaginal 3D Image-Guided High Intensity Focused Ultrasound Array
NASA Astrophysics Data System (ADS)
Held, Robert; Nguyen, Thuc Nghi; Vaezy, Shahram
2005-03-01
The goal of this project is to develop a transvaginal image-guided High Intensity Focused Ultrasound (HIFU) device using piezocomposite HIFU array technology, and commercially-available ultrasound imaging. Potential applications include treatment of uterine fibroids and abnormal uterine bleeding. The HIFU transducer was an annular phased array, with a focal length range of 30-60 mm, an elliptically-shaped aperture of 35×60 mm, and an operating frequency of 3 MHz. A pillow-shaped bag with water circulation will be used for coupling the HIFU energy into the tissue. An intra-cavity imaging probe (C9-5, Philips) was integrated with the HIFU array such that the focal axis of the HIFU transducer was within the image plane. The entire device will be covered by a gel-filled condom when inserted in the vaginal cavity. To control it, software packages were developed in the LabView programming environment. An imaging algorithm processed the ultrasound image to remove noise patterns due to the HIFU signal. The device will be equipped with a three-dimensional tracking system, using a six-degrees-of-freedom articulating arm. Necrotic lesions were produced in a tissue-mimicking phantom and a turkey breast sample for all focal lengths. Various HIFU doses allow various necrotic lesion shapes, including thin ellipsoidal, spherical, wide cylindrical, and teardrop-shaped. Software control of the device allows multiple foci to be activated sequentially for desired lesion patterns. Ultrasound imaging synchronization can be achieved using hardware signals obtained from the imaging system, or software signals determined empirically for various imaging probes. The image-guided HIFU device will provide a valuable tool in visualization of uterine fibroid tumors for the purposes of planning and subsequent HIFU treatment of the tumor, all in a 3D environment. The control system allows for various lesions of different shapes to be optimally positioned in the tumor to cover the entire tumor volume. Real-time ultrasound imaging for guidance and monitoring of HIFU treatment provides an effective method for outpatient-based procedures.
Can anyone screen for deep infiltrating endometriosis with transvaginal ultrasound?
Piessens, Sofie; Healey, Martin; Maher, Peter; Tsaltas, Jim; Rombauts, Luk
2014-10-01
Surgical treatment of deep infiltrating endometriosis (DIE) is complex, and preoperative diagnosis benefits both surgeon and patient. Studies in expert centres have reported high accuracy for transvaginal ultrasound (TVUS) diagnosis of DIE. External validation of these findings has been limited, and no information is available on how quickly these skills can be acquired. The aim of this study was to measure the learning curve of DIE-TVUS and to identify the causes for inaccuracies in the diagnosis of bowel lesions and Pouch of Douglas (POD) obliteration. Following one week of training at the University of São Paulo (Brazil), 205 consecutive women with a history of endometriosis symptoms were prospectively assessed by TVUS after minimal bowel preparation. TVUS findings were correlated with laparoscopic findings in eighty-five cases to assess the accuracy. The LC-CUSUM and CUSUM were used to assess the learning curve and maintenance of competency, respectively. The sensitivity and specificity for DIE of the bladder, vagina and bowel were 33% and 100%, 80% and 100%, and 88% and 93%, respectively. The sensitivity and specificity for the presence of POD obliteration were 88% and 90%, respectively. LC-CUSUM analysis confirmed that competency for DIE-TVUS was achieved within 38 scans for the detection of POD obliteration and within 36 scans for the detection of bowel nodules. Competency was maintained for the remainder of the scans as assessed by the CUSUM. After one week of DIE-TVUS training, competency can be achieved within forty procedures, allowing diagnosis of DIE with similar diagnostic accuracy as reported by centres of excellence. © 2014 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Ultrasound cervical length measurement in prediction of labor induction outcome.
Kehila, M; Abouda, H S; Sahbi, K; Cheour, H; Chanoufi, M Badis
2016-05-17
Induction of labor is one of the most common procedures in modern obstetrics, with an incidence of approximately 20% of all deliveries. Not all of these inductions result in vaginal delivery; some lead to cesarean sections, either for emergency reasons or for failed induction. That's why, It seems necessary to outline strategies for the improvement of the success rate of induced deliveries. Traditionally, the identification of women in whom labor induction is more likely to be successful is based on the Bishop score. However, several studies have shown it to be subjective, with high variation and a poor predictor of the outcome of labor induction. Transvaginal sonography for cervical measurement can be a more objective criterion in assessing the success of labor induction. Many studies have been done recently to compare cervical measurement and Bishop Score in labor induction.This paper reviewed the literature that evaluated sonographic cervical length measurement to predict induction of labor outcome.
Laparoscopic management of interstitial pregnancy with automatic stapler
Ahsan Akhtar, Muhammad; Izzat, Feras; Keay, Stephen D
2012-01-01
A 36-year-old woman was referred by general practitioner to the early pregnancy unit with pelvic pain in her seventh week of pregnancy. She had a transvaginal ultrasound. Unruptured live twin tubal ectopic pregnancy was diagnosed on. Diagnostic laparoscopy revealed an unruptured left interstitial ectopic pregnancy. The interstitial tubal pregnancy was removed by laparoscopic automatic stapler with minimal blood loss. The patient had an uneventful recovery to health. PMID:23093504
Api, Murat
2009-12-01
A number of novel surgical modalities that destroy or remove some ovarian tissue to restore ovarian function in patients with polycystic ovary syndrome have been described in the most recent literature. Although these modalities were reported to have easy applicability and low cost with shorter hospital stay, the efficacy and safety concerns need to be discussed extensively.
Alcázar, Juan Luis; Gastón, Begoña; Navarro, Beatriz; Salas, Rocío; Aranda, Juana; Guerriero, Stefano
2017-11-01
To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%-82%) and 82% (95% CI=75%-93%) for TVS, and 83% (95% CI=76%-89%) and 82% (95% CI=72%-89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology
Successful pregnancy after treatment with ulipristal acetate for uterine fibroids.
Monleón, Javier; Martínez-Varea, Alicia; Galliano, Daniela; Pellicer, Antonio
2014-01-01
This case report presents a clinical pregnancy after ulipristal acetate (UA) to decrease uterine fibroid size. A 37-year-old patient, gravida 1, abortus 1, with uterine fibroids was treated with 5 mg of UA daily for 13 weeks starting eight months after a multiple laparotomic myomectomy. Fibroid shrinkage and restoration of the morphology of endometrial cavity were evaluated in order to allow a subsequent pregnancy. A decrease of the uterine fibroids and a normal morphology of the endometrial cavity were noted by transvaginal ultrasound after treatment. An endometrial biopsy excluded histologic endometrial changes. Three months after the end of UA the patient reported amenorrhea for 5 weeks and a clinical pregnancy was confirmed with transvaginal ultrasound. She underwent a subsequent uneventful pregnancy. Thus, the spontaneous pregnancy after UA to reduce fibroid size may support the potential clinical utility of this selective progesterone receptor modulator in the management of women with pregnancy desire and uterine fibroids after a prior myomectomy. Patients who refuse a new surgical procedure and/or those who are going to undergo assisted reproductive techniques would benefit from UA. It effectively shrinks fibroids, avoids risks of a new surgical procedure, and allows an immediate attempt at conception after the end of treatment.
Racial and ethnic disparities in universal cervical length screening with transvaginal ultrasound
Haviland, Miriam J; Shainker, Scott A; Hacker, Michele R; Burris, Heather H
2016-01-01
Objective Determine if race or ethnicity is associated with missed or late transvaginal cervical length screening in a universal screening program. Methods Retrospective cohort study of nulliparous women with singleton gestations and a fetal anatomical ultrasound from 16-24 weeks' gestation from January, 2012 through November, 2013. We classified women into mutually exclusive racial and ethnic groups: non-Hispanic black (black), Hispanic, Asian, non-Hispanic white (white), and other or unknown race. We used log-binomial regression to calculate the risk ratio (RR) and 95% confidence interval (CI) of missed or late (≥ 20 weeks' gestation) screening vs. optimally-timed screening between the different racial and ethnic groups. Results Among the 2 967 women in our study population, 971 (32.7%) had either missed or late cervical length screening. Compared to white women, black (RR: 1.3; 95% CI:1.1-1.5) and Hispanic (RR:1.2; 95% CI:1.01-1.5) women were more likely to have missed or late screening. Among women screened, black (vs. white) women were more likely to be screened late (RR: 2.2; 95% CI: 1.6-3.1). Conclusions Black and Hispanic women may be more likely to have missed or late cervical length screenings. PMID:26987873
2017-01-01
Objective To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting myometrial infiltration (MI) in endometrial carcinoma. Methods An extensive search of papers comparing TVS and MRI in assessing MI in endometrial cancer was performed in MEDLINE (PubMed), Web of Science, and Cochrane Database from January 1989 to January 2017. Quality was assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results Our extended search identified 747 citations but after exclusions we finally included in the meta-analysis 8 articles. The risk of bias for most studies was low for most 4 domains assessed in QUADAS-2. Overall, pooled estimated sensitivity and specificity for diagnosing deep MI were 75% (95% confidence interval [CI]=67%–82%) and 82% (95% CI=75%–93%) for TVS, and 83% (95% CI=76%–89%) and 82% (95% CI=72%–89%) for MRI, respectively. No statistical differences were found when comparing both methods (p=0.314). Heterogeneity was low for sensitivity and high for specificity for TVS and MRI. Conclusion MRI showed a better sensitivity than TVS for detecting deep MI in women with endometrial cancer. However, the difference observed was not statistically significant. PMID:29027404
Marcellin, Louis; Senat, Marie Victoire; Benachi, Alexandra; Regis, Sophie; Cabrol, Dominique; Goffinet, François
2017-05-24
To evaluate whether routine measurement of cervical length (CL) by transvaginal ultrasound (TVU) in twin pregnancies can enable identification of women who will give birth before 34 weeks and require antenatal corticosteroids (ACSs), and whether it can limit their administration to women who will give birth later. Retrospective comparative study in two tertiary referral centers in France. Women with twin gestations followed in two tertiary university hospital maternity units and who delivered from January 1, 2007 to December 31, 2009 were included. In one center, TVU was targeted to women with cases of suspected preterm labor, while the other center used it monthly for all twin pregnancies. The main outcome measure was the administration of a full course of ACS to twins delivered before 34 weeks. Two hundred and seventy women were eligible in the "targeted use" group, and 296 women in the "routine use" group. The rate of administration of at least one full course of ACS for twins born before 34 weeks did not differ between the two groups (85.0% in the targeted use group and 90.0% in the routine use group, P=0.40), but the rate of such administration for those born after 34 weeks was lower in the targeted use group (25.7% vs. 81.2%, P<0.01). On adjusting for confounders using logistic regression modeling, no significant difference in ACS administration before 34 weeks was found between the two groups [adjusted odds ratio (aOR), 0.71, 95% confidence interval (CI), 0.39-1.30]. Routine monitoring performed every month of CL with TVU does not affect the rate of administration of ACS to twins born before 34 weeks, but is associated with a higher rate of such administration for those born later in the specific center of the study.
Face and content validity of the virtual reality simulator 'ScanTrainer®'.
Alsalamah, Amal; Campo, Rudi; Tanos, Vasilios; Grimbizis, Gregoris; Van Belle, Yves; Hood, Kerenza; Pugh, Neil; Amso, Nazar
2017-01-01
Ultrasonography is a first-line imaging in the investigation of women's irregular bleeding and other gynaecological pathologies, e.g. ovarian cysts and early pregnancy problems. However, teaching ultrasound, especially transvaginal scanning, remains a challenge for health professionals. New technology such as simulation may potentially facilitate and expedite the process of learning ultrasound. Simulation may prove to be realistic, very close to real patient scanning experience for the sonographer and objectively able to assist the development of basic skills such as image manipulation, hand-eye coordination and examination technique. The aim of this study was to determine the face and content validity of a virtual reality simulator (ScanTrainer®, MedaPhor plc, Cardiff, Wales, UK) as reflective of real transvaginal ultrasound (TVUS) scanning. A questionnaire with 14 simulator-related statements was distributed to a number of participants with differing levels of sonography experience in order to determine the level of agreement between the use of the simulator in training and real practice. There were 36 participants: novices ( n = 25) and experts ( n = 11) who rated the simulator. Median scores of face validity statements between experts and non-experts using a 10-point visual analogue scale (VAS) ratings ranged between 7.5 and 9.0 ( p > 0.05) indicated a high level of agreement. Experts' median scores of content validity statements ranged from 8.4 to 9.0. The findings confirm that the simulator has the feel and look of real-time scanning with high face validity. Similarly, its tutorial structures and learning steps confirm the content validity.
Franchi, Dorella; Boveri, Sara; Radice, Davide; Portuesi, Rosalba; Zanagnolo, Vanna; Colombo, Nicoletta; Testa, Antonia Carla
2016-12-01
Borderline ovarian tumors are generally diagnosed in young women. Because of the young age of patients at first diagnosis and at recurrence, and given the good prognosis of borderline ovarian tumors, a conservative surgical approach in those women who wish to preserve their fertility is advised. In this scenario, transvaginal ultrasound examination plays a key role in the detection of borderline ovarian tumor recurrence, and in assessment of amount of normal functioning parenchyma remaining. To date, no data are available about the natural history of borderline ovarian tumor recurrence. The aim of the study was to determine growth rate of recurrent ovarian cysts by a scheduled follow-up by ultrasound examination, in women previously treated with fertility-sparing surgery due to borderline ovarian tumors. In this prospective observational study, we collected data from 34 patients previously treated with fertility-sparing surgery due to borderline ovarian tumors, who had a suspicious recurrent lesion. The patients underwent transvaginal ultrasonographic examination every 3 months, until the clinical setting recommended proceeding with surgery. According to cyst size at study entry, they were categorized into 3 groups: ≤10 mm, 10-20 mm, and >20 mm. Summary statistics for cyst size, growth rate, and the probability of remaining within the same dimension category at first ultrasound during the follow-up were also obtained. For each cyst the growth rate was calculated as the slope of the linear interpolation between 2 consecutive measurements. Follow-up timing (P < .001), cyst size (P < .001), and micropapillary pattern (P < .001) were factors significantly affecting the cyst growth both in univariate and multivariate analysis. According to size category at first ultrasound, growth rate ranges from a minimum of 0.06 mm/mo for cysts <10 mm up to 1.92 mm/mo for cysts >20 mm. The final histology of all recurrent lesions confirmed the same histotype of primary borderline ovarian tumors. This article represents the first observational study that describes the trend in the growth rate of borderline ovarian tumor recurrence in relation to their size detected at the first ultrasound examination. The findings of this study seem to confirm, in selected patients, that a thorough ultrasonographic follow-up of borderline ovarian tumor recurrence has proven to be safe and feasible. The final goal of such management is to maximize the impact on fertility potential of these young women without worsening their prognosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.
Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling
2012-07-01
To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Imaging for Polyps and Leiomyomas in Women With Abnormal Uterine Bleeding: A Systematic Review.
Maheux-Lacroix, Sarah; Li, Fiona; Laberge, Philippe Y; Abbott, Jason
2016-12-01
To evaluate the accuracy of saline infusion sonohysterography in comparison with transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We searched the databases MEDLINE, EMBASE, CENTRAL, and ClinicalTrials.gov as well as citations and reference lists to the end of November 2015. Two authors screened 5,347 citations for eligibility. We included randomized controlled trials or prospective cohort studies published in English, assessing the accuracy of saline infusion sonohysterography and transvaginal ultrasonography for diagnosing polyps and submucosal leiomyomas in women with abnormal uterine bleeding. We considered studies using histopathologic specimens obtained at either hysteroscopy or hysterectomy as criterion standard. Twenty-five studies were eligible. Two authors extracted data and assessed the quality of included studies. Bivariate random-effects models were used to compare the different tests and evaluate sources of heterogeneity. Saline infusion sonohysterography was superior to transvaginal ultrasonography with pooled sensitivity and specificity of 0.92 and 0.89 compared with 0.64 and 0.90, respectively (P<.001). Transvaginal ultrasound sensitivity for diagnosing polyps was particularly low (0.51). Saline infusion sonohysterography was also compared with hysteroscopy in seven studies and had similar sensitivity but inferior specificity (0.93 and 0.83 compared with 0.95 and 0.90, respectively, P=.007). All three procedures were well-tolerated by women. Saline infusion sonohysterography was successfully completed in 95% of women. Technical variations such as the use of balloon catheters were not found to affect diagnostic accuracy. Transvaginal ultrasonography lacks sensitivity to be used alone to exclude the presence of polyps and leiomyomas in women with abnormal uterine bleeding. Although less specific than hysteroscopy, saline infusion sonohysterography offers a similar detection rate and permits concomitant visualization of the ovaries and myometrium. Cost, convenience, and tolerability of different imaging techniques require further evaluation. PROSPERO International prospective register of systematic reviews, http://www.crd.york.ac.uk/PROSPERO, CRD42016034005.
Kowalczyk, Dariusz; Guzikowski, Wojciech; Więcek, Jacek; Sioma-Markowska, Urszula
2012-01-01
In many publications the transvaginal ultrasound is regarded as the first step to diagnose the cause of uterine bleeding in perimenopausal women. In order to improve the sensitivity and specificity of the conventional ultrasound physiological saline solution was administered to the uterine cavity and after expansion of its walls the interior uterine cavity was examined. And this procedure is called 2D sonohysterography (SIS 2D). By the ultrasound scanners which enable to get 3D real time image a spatial evaluation of the uterine cavity is possible. Clinical value of the real time 3D sonohysterography and 2D sonohysterography compared to hysteroscopy with histopathological examination in perimenopausal women. The study concerned a group of 97 perimenopausal women with abnormal uterine bleeding. In all of them after a standard transvaginal ultrasonography a catheter was inserted into the uterine cavity. After expansion of the uterine walls by administering about 10 ml of 0,9% saline solution the uterine cavity was examined by conventional sonohysterography. Then a 3D imaging mode was activated and the uterine interior was examined by real time 3D ultrasonography. The ultrasound results were verified by hysteroscopy, the endometrial lesions were removed and underwent a histopathological examination. In two cases the SIS examination was impossible because of uterine cervix atresion. In the rest of examined group the SIS 2D sensitivity and specificity came up to 72 and 96% respectively. In the group of SIS 3D the sensitivity and specificity reached 83 and 99% respectively. Adding SIS 3D, a minimally invasive method, to conventional sonohysterography improves the precision of diagnosis of endometrial pathology, allows to get three-dimensional image of the uterine cavity and enables examination of endometrial lesions. The diagnostic precision of this procedure is similar to the results achieved by hysteroscopy.
Malvasi, Antonio; Stark, Michael; Ghi, Tullio; Farine, Dan; Guido, Marcello; Tinelli, Andrea
2012-05-01
The primary goal of this study was to determine the ultrasonographic signs of asynclitic and transverse head positioning. In addition, we compared the performance of intrapartum ultrasound to vaginal digital examination. 150 women were evaluated by 2D transabdominal and translabial ultrasound (US) to detect the asynclitic and deep transverse positions. Transvaginal sterile digital examinations were performed immediately after each intrapartum US assessments, the examinations were repeated at intervals of 45-90 minutes. Examiners were blinded to each other's findings (clinical or sonographic). Data were reviewed and analyzed by an independent reviewer. The efficacy of digital examination was significantly lower than US evaluation for the detection of either transverse position or asynclitism. The most frequent transverse position was the left one, while the most frequent asynclitism was the anterior one. Digital pelvic examination for detection of fetal head transverse position during labor is inferior to US, especially in the deep transverse positioning, where caput succedaneum occurs and reduces the diagnostic accuracy of vaginal digital examination. The US examination leads to early detection of persistent transverse position allowing for earlier timing and optimal technique for the operative vaginal delivery. We describe two signs for diagnosing asynclitism. The "squint sign" and the "sunset of thalamus and cerebellum signs" are two simple US signs allowing detection of anterior and posterior asynclitism.
Palermo, Fernanda Gasparin; Albuquerque, Débora de Paula Soares de Medeiros; Martins, Wellington P; Araujo Júnior, Edward; Bruns, Rafael Frederico
2016-09-01
To establish a structured review process to facilitate the identification of the fetal nasal bone (NB) in the first trimester ultrasound scan to improve the quality images. We conducted a retrospective observational study in fetal NB images obtained during ultrasound exams of singleton pregnancies that underwent first trimester screening (crown-rump length 45-84 mm). When the images were obtained the examiner was not aware of the study. Audit was conducted by an examiner according criteria established by the Fetal Medicine Foundation. Fetal NB images were assessed regarding adequate magnification, mid-sagittal view and transducer held parallel to the direction of the nose. The transvaginal and transabdominal as well as anterior and posterior fetal back groups were compared using χ(2) test. We considered 874 fetal NB images for auditing. Fetal NB was considered present in 865 images (99%). During the audit process, we identified 72 (8.2%) cases of disagreement between examiner and auditor assessments. Disagreement was higher when image quality was poor (62 cases = 7%). Transvaginal approach performed better in the following criteria: adequate magnification (p < 0.001), midline (p < 0.001) and completely adequate (p < 0.001). A peer reviewed audit program for fetal NB is feasible in a clinical scenario. Image quality appears to play an important role in compliance to image standards audited and in agreement between examiner and auditor.
Intrauterine endometrial cyst after low uterine incision: A case report with literature review.
Yin, Weiyao; Zhang, Jiawen; Xu, Liangzhi; Luo, Li
2018-04-01
During the surgical procedure, endometrial cells can be seeded into the wound edge of the uterine wall, developing into scar endometriosis. Due to the extremely low incidence, estimation of its prevalence is still unavailable. Even rarer might be the scar endometriosis in uterine cavity, to our best knowledge, a situation has not been reported yet. A 37-year-old woman complained of heavier and prolonged menstruation as well as pelvic pain during menses for more than 4 months. An endometrial cyst in diameter of 6 cm in uterine cavity was revealed by transvaginal ultrasound. Her surgical history was significant for 1 caesarean section and 1 abdominal myomectomy through transverse incision of lower uterine segment. Space-occupying lesions in uterine cavity, moderate anemia and scar uterus. The hysteroscopy was performed and a multilocular cyst full of chocolate-like fluid was removed. Pathological examination confirmed endometrial glands in the removed cyst tissue. During the follow-up visits at 1 and 6 months after surgery, the patient denied any special discomfort. Her postoperative transvaginal ultrasound showed an enlarged uterus with no lesion in uterine cavity. To achieve a better surveillance, a 3-year period of follow-up after surgery at a 6-month interval was suggested. Intrauterine endometriosis should be considered in patients of pelvic surgery history with pelvic pain, menstrual disorder, and intrauterine cystic mass.
Cervical Length in Patients at Risk for Placenta Accreta.
Rac, Martha W F; McIntire, Donald D; Wells, C Edward; Moschos, Elysia; Twickler, Diane D
2017-07-01
To evaluate cervical length measurements in women with placenta accreta compared to women with a nonadherent low-lying placenta or placenta previa and evaluate this relationship in terms of vaginal bleeding, preterm labor, and preterm birth. We conducted a retrospective cohort study between 1997 and 2011 of gravidas with more than 1 prior cesarean delivery who had a transvaginal ultrasound examination between 24 and 34 weeks for a low-lying placenta or placenta previa. Cervical length was measured from archived images in accordance with national guidelines by a single investigator, who was blinded to outcomes and ultrasound reports. The diagnosis of placental accreta was based on histologic confirmation. For study purposes, preterm birth was defined as less than 36 weeks, and cervical lengths of 3 cm or less were considered short. Standard statistical analyses were used. A total of 125 patients met inclusion criteria. The cohort was divided into patients with (n = 43 [34%]) and without (n = 82 [66%]) placenta accreta and stratified by gestational age at the ultrasound examinations. Women with placenta accreta had shorter cervical length measurements during their 32- to 34-week ultrasound examinations (mean ± SD, 3.23 ± 0.98 versus 3.95 ± 1.0 cm; P < .01) and were more likely to have a short cervix of 3 cm or less (P = .001). However, these findings did not correlate with the degree of invasion (P = .3), or higher rates of vaginal bleeding and preterm labor (P = .19) resulting in preterm birth before 36 weeks (P = .64). Women with placenta accreta had shorter cervical lengths at 32 to 34 weeks than women with a nonadherent low-lying placenta or placenta previa, but this finding did not correlate with a higher risk of vaginal bleeding or preterm labor resulting in preterm birth before 36 weeks. © 2017 by the American Institute of Ultrasound in Medicine.
Objective diagnosis of arrested labor on transperineal ultrasound.
Nishimura, Kazuaki; Yoshimura, Kazuaki; Kubo, Tatsuhiko; Hachisuga, Toru
2016-07-01
Recent developments in transperineal ultrasound imaging of the pelvis have prompted trials to objectively evaluate labor progression for labor management. We evaluated the accuracy of transperineal ultrasound in diagnosing arrest of labor. Transperineal ultrasound and digital pelvic examinations were performed simultaneously in 63 term laboring patients (singleton fetuses in cephalic presentation). We analyzed a total of 216 ultrasound images (Sonography Volume Computer Aided Display Labor [Sono VCAD Labor®] installed in Voluson E8 ultrasound). We examined the correlation between the three ultrasound parameters head direction (HD), progression distance (PD), and progression angle (PA), and digital pelvic examination findings during labor in a transvaginal delivery group and an arrested labor group. The coefficient of correlations between HD/PD/PA and cervical dilation/fetal station were 0.667/0.657/0.706 and 0.667/0.751/0.803, respectively. The three parameters had strong correlations with digital pelvic examination (P < 0.05). In the 11 cases (17%) of cesarean section due to arrested labor, the position of the fetal head was visually unchanged on sequential ultrasound images. According to receiver operating characteristic curves, the significant cut-offs for HD, PD, and PA for arrested labor were 105° (P = 0.048), 35 mm (P = 0.048), and 120° (P = 0.001), respectively. Transperineal ultrasound imaging is helpful for objective evaluation of labor progression and the diagnosis of arrested labor. © 2016 Japan Society of Obstetrics and Gynecology.
Chaudhari, Uddhav K; Imran, M; Manjramkar, Dhananjay D; Metkari, Siddhanath M; Sable, Nilesh P; Gavhane, Dnyaneshwar S; Katkam, Rajendra R; Sachdeva, Geetanjali; Thakur, Meenakshi H; Kholkute, Sanjeeva D
2017-02-01
Ultrasound is a powerful, low-cost, non-invasive medical tool used by laboratory animal veterinarians for diagnostic imaging. Sonohysterography and transvaginal ultrasound are frequently used to assess uterine anomalies in women presenting with abnormal uterine bleeding (AUB). In the present study, we have evaluated the abdominal ultrasound of bonnet monkeys ( n = 8) showing spontaneous ovulatory ( n = 5) and anovulatory ( n = 3) AUB. The ovulatory ( n = 5) macaques showed cyclic AUB for 7-8 days. The anovulatory ( n = 3) macaques had irregular AUB with menstrual cycles of 40-45 days. The B-mode abdominal, colour Doppler and 3D ultrasound scans were performed during the proliferative phase of the menstrual cycle. Ultrasound examination revealed endometrial polyps in five macaques and endometrial hyperplasia in three animals. The width and length of endometrial polyps was around 0.5-1 cm (average 0.51 ± 0.23 cm × 0.96 ± 0.16 cm) with significant increase in endometrial thickness ( P < 0.0002). 3D ultrasound also showed a homogeneous mass in the uterine cavity and colour Doppler ultrasound showed increased vascularity in the endometrial polyps. Endometrial hyperplasia characteristically appeared as a thickened echogenic endometrium ( P < 0.0002). This study demonstrates the use of non-invasive ultrasound techniques in the diagnosis of AUB in macaques.
Huang, Wen-Chen; Yang, Jenn-Ming
2017-03-01
The purpose of this study was to explore the association between mesh location and de novo stress urinary incontinence (SUI) after transvaginal mesh procedures. We retrospectively analyzed a database of women who had received transvaginal mesh procedures for stage III or greater cystocele according to the Pelvic Organ Prolapse Quantification system. Only data for women who neither reported SUI preoperatively nor had received concomitant anti-incontinence surgery were included for analyses. The mesh location was investigated by sonography via the percentage of the urethra covered by mesh, defined as the number calculated by dividing the portion of the urethral length covered by mesh (the distance from the bladder neck to the point of the urethra, which was indicated by an imaginary line at the level of the lower [caudal] mesh end and perpendicular to the urethra) by the total urethral length (the distance from the bladder neck to the external urethral meatus) in the sagittal plane. The resting, straining, coughing, and squeezing mesh locations of women who did (n = 29) and did not (n = 54) report SUI at the 12-month follow-up were compared. At the 12-month follow-up, women who reported SUI had a significantly smaller straining percentage of the urethra covered by mesh (mean ± SD, 28.5% ± 9.6%) compared with continent women (35.2% ± 15.8%), indicating a more proximal straining mesh location. Sonography is useful in investigating the location of the transvaginal mesh. De novo SUI after transvaginal mesh procedures is associated with a more proximal straining mesh location. © 2017 by the American Institute of Ultrasound in Medicine.
The role of abnormal fetal heart rate in scheduling chorionic villus sampling.
Yagel, S; Anteby, E; Ron, M; Hochner-Celnikier, D; Achiron, R
1992-09-01
To assess the value of fetal heart rate (FHR) measurements in predicting spontaneous fetal loss in pregnancies scheduled for chorionic villus sampling (CVS). A prospective descriptive study. Two hospital departments of obstetrics and gynaecology in Israel. 114 women between 9 and 11 weeks gestation scheduled for chorionic villus sampling (CVS). Fetal heart rate was measured by transvaginal Doppler ultrasound and compared with a monogram established from 75 fetuses. Whenever a normal FHR was recorded, CVS was performed immediately. 106 women had a normal FHR and underwent CVS; two of these pregnancies ended in miscarriage. In five pregnancies no fetal heart beats could be identified and fetal death was diagnosed. In three pregnancies an abnormal FHR was recorded and CVS was postponed; all three pregnancies ended in miscarriage within 2 weeks. Determination of FHR correlated with crown-rump length could be useful in predicting spontaneous miscarriage before performing any invasive procedure late in the first trimester.
Timor-Tritsch, Ilan E; Haynes, Meagan Campol; Monteagudo, Ana; Khatib, Nizar; Kovács, Sándor
2016-06-01
Arteriovenous malformation is a short circuit between an organ's arterial and venous circulation. Arteriovenous malformations are classified as congenital and acquired. In the uterus, they may appear after curettage, cesarean delivery, and myomectomy among others. Their clinical feature is usually vaginal bleeding, which may be severe, if curettage is performed in unrecognized cases. Sonographically on 2-dimensional grayscale ultrasound scanning, the pathologic evidence appears as irregular, anechoic, tortuous, tubular structures that show evidence of increased vascularity when color Doppler is applied. Most of the time they resolve spontaneously; however, if left untreated, they may require involved treatments such as uterine artery embolization or hysterectomy. In the past, uterine artery angiography was the gold standard for the diagnosis; however, ultrasound scanning has diagnosed successfully and helped in the clinical management. Recently, arteriovenous malformations have been referred to as enhanced myometrial vascularities. The purpose of this study was to evaluate the role of transvaginal ultrasound scanning in the diagnosis and treatment of acquired enhanced myometrial vascularity/arteriovenous malformations to outline the natural history of conservatively followed vs treated lesions. This was a retrospective study to assess the presentation, treatment, and clinical pictures of patients with uterine Enhanced myometrial vascularity/arteriovenous malformations that were diagnosed with transvaginal ultrasound scanning. We reviewed both (1) ultrasound data (images, measured dimensions, and Doppler blood flow that were defined by its peak systolic velocity and (2) clinical data (age, reproductive status, clinical presentation, inciting event or procedure, surgical history, clinical course, time intervals that included detection to resolution or detection to treatment, and treatment rendered). The diagnostic criteria were "subjective" with a rich vascular network in the myometrium with the use of color Doppler images and "objective" with a high peak systolic velocity of ≥20 cm/sec in the vascular web. Statistical analysis was performed and coded with statistical software where necessary. Twenty-seven patients met the diagnostic criteria of uterine enhanced myometrial vascularity/arteriovenous malformation. Mean age was 31.8 years (range, 18-42 years). Clinical diagnoses of the patients included 10 incomplete abortions, 6 missed abortions, 5 spontaneous complete abortions, 5 cesarean scar pregnancies, and 1 molar pregnancy. Eighty-nine percent of patients had bleeding (n = 24/27), although 1 patient was febrile, and 2 patients were asymptomatic. Recent surgical procedures were performed in 55.5% patients (15/27) that included curettage (n = 10), cesarean deliveries (n = 5), or both (n = 1); 4 patients had a remote history of uterine surgery that included myomectomy. Treatment was varied and included expectant treatment alone in 48% of the patients with serial ultrasound scans and serum human chorionic gonadotropin until resolution (n = 13/27 patients), uterine artery embolization (29.6%; 8/27 patients), methotrexate administration (22.2%; 6/27 patients), hysterectomy (7.4%; 2/27 patients), and curettage (3.7%; 1/27 patients). Three patients required a blood transfusion. Of the 9 patients whose condition required embolization, the conditions of 7 patients resolved after the procedure although 1 patient's condition required operative hysteroscopy and 1 patient's condition required hysterectomy for intractable bleeding. Average peak systolic velocity after embolization in the 9 patients was 85.2 cm/sec (range, 35-170 cm/sec); the average peak systolic velocity of the 16 patients with spontaneous resolution was 58.5 cm/sec (range, 23-90 cm/sec). Acquired enhanced myometrial vascularity/arteriovenous malformations occurred after unsuccessful pregnancies or treatment procedures that included uterine curettage, cesarean delivery, or cesarean scar pregnancy. Triage of patients for expectant treatment vs intervention with uterine artery embolization based on their clinical status, which was supplemented by objective measurements of blood velocity measurement in the arteriovenous malformation, appears to be a good predictor of outcome. Ultrasound evaluation of patients with early pregnancy failure and persistent bleeding should be considered for evaluation of a possible enhanced myometrial vascularity/arteriovenous malformation. Copyright © 2016 Elsevier Inc. All rights reserved.
Giampaolino, Pierluigi; Morra, Ilaria; De Rosa, Nicoletta; Cagnacci, Angelo; Pellicano, Massimiliano; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe
2017-09-01
Polycystic ovarian syndrome (PCOS) is the most common endocrine disorder in gynecology. In PCOS patients vascularization parameters are altered. Transvaginal hydrolaparoscopy (THL) is a mini-invasive approach for ovarian drilling in PCOS patients. In this study, we assessed the effect of ovarian drilling using THL on ovarian volume (OV) and vascularization index (VI) using 3D power Doppler ultrasonography in CC-resistant PCOS patients. A case-control study on 123 CC-resistant PCOS women who underwent THL ovarian drilling was performed. Patients underwent 3D ultrasound and power Doppler to measure VI, flow index (FI), vascularization flow index (VFI) and to evaluate OV before and after the procedure, at six months, and on the early follicular phase of the menstrual cycle. After THL ovarian drilling, OV and power Doppler flow indices were significantly reduced compared to pre-operative values (OV: 7.85 versus 11.72 cm 3 , p < 0.01; VI: 2.50 versus 4.81, p < 0.01; VFI: 1.10 versus 2.16, p < 0.01; FI: 32.05 versus 35.37, p < 0.01). In conclusion, THL ovarian drilling seems to reduce OV and 3D power Doppler indices, and could therefore be a viable alternative to LOD in PCOS patients resistant to medical therapy.
Pilkington, Sophie A; Grierson, Catherine; Rutherford, Elizabeth; Schizas, Alexis M P; Nugent, Karen P; Williams, Andrew B
2016-01-01
Objective: Defaecatory MRI allows multicompartmental assessment of defaecatory dysfunction but is often inaccessible. Integrated total pelvic floor ultrasound (transperineal, transvaginal, endoanal) may provide a cheap, portable alternative. The accuracy of total pelvic floor ultrasound for anatomical abnormalities when compared with defaecatory MRI was assessed. Methods: The dynamic images from 68 females who had undergone integrated total pelvic floor ultrasound and defaecatory MRI between 2009 and 2015 were blindly reviewed. The following were recorded: rectocoele, enterocoele, intussusception and cystocoele. Results: There were 26 rectocoeles on MRI (49 rectocoeles on ultrasound), 24 rectocoeles with intussusception on MRI (19 rectocoeles on ultrasound), 23 enterocoeles on MRI (24 enterocoeles on ultrasound) and 49 cystocoeles on MRI (35 cystocoeles on ultrasound). Sensitivity and specificity of total pelvic floor ultrasound were 81% and 33% for rectocoele, 60% and 91% for intussusception, 65% and 80% for enterocoele and 65% and 84% for cystocoele when compared with defaecatory MRI. This gave a negative-predictive value and positive-predictive value of 74% and 43% for rectocoele, 80% and 79% for intussusception, 82% and 63% for enterocoele and 48% and 91% for cystocoele. Conclusion: Integrated total pelvic floor ultrasound may serve as a screening tool for pelvic floor defaecatory dysfunction; when normal, defaecatory MRI can be avoided, as rectocoele, intussusception and enterocoele are unlikely to be present. Advances in knowledge: This is the first study to compare integrated total pelvic floor ultrasound with defaecatory MRI. The results support the use of integrated total pelvic floor ultrasound as a screening tool for defaecatory dysfunction. PMID:27730818
[Feedback of ultrasound and RMI in the staging of endometrial carcinoma in early stage].
Buhler, J; Routiot, T; Polet-Lefebvre, K; Morel, O
2015-04-01
Endometrial cancer is the most common gynecological cancer in France. The therapeutic management is based on preoperative staging. The recommended imaging examination remains the MRI. This is to evaluate ultrasound and MRI in the staging for localized cancers. This is a retrospective observational study, conducted from July 2012 to July 2014, at the University Hospital of Nancy, on all patients care for endometrial cancer stage I, who underwent a pelvic ultrasound and MRI for the assessment of myometrial infiltration. Twenty-nine patients were included with a mean age of 69 years and a BMI of 30 kg/m(2). Using ultrasound, we have a sensitivity of 58%, a specificity of 100%, a positive predictive value (PPV) of 100%, a negative predictive value (NPV) of 70% and an accuracy of 75%. Using MRI, we have a sensitivity of 83%, a specificity of 100%, a PPV of 83%, a VPN of 88%, and an accuracy of 86%. Transvaginal sonography should be performed before post-menopausal bleeding. It remains possible in the staging of localized cancers. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Transabdominal ultrasonography as a screening test for second-trimester placenta previa.
Quant, Hayley S; Friedman, Alexander M; Wang, Eileen; Parry, Samuel; Schwartz, Nadav
2014-03-01
To determine the test characteristics of transabdominal ultrasonography as a screening test for second-trimester placenta previa. This secondary analysis of a prospective cohort study evaluated the distance from the placental edge to the internal os (placenta-cervix distance) through both transabdominal and transvaginal ultrasonography during the anatomic survey. Patients were recruited in the Maternal-Fetal Medicine Ultrasound Unit at the Hospital of the University of Pennsylvania, an urban tertiary care center. Transabdominal placenta-cervix distance cutoffs with high sensitivity for detection of previa and low-lying placenta were identified, and test characteristics were calculated. Follow-up ultrasound data, pregnancy, and delivery outcomes for those with second-trimester previa or low-lying placenta were obtained. One thousand two hundred fourteen women were included in the analysis. A transabdominal placenta-cervix distance cutoff of 4.2 cm was 93.3% sensitive and 76.7% specific for detection of previa with a 99.8% negative predictive value at a screen-positive rate of 25.0%. A cutoff of 2.8 cm was 86.7% sensitive and 90.5% specific with a 99.6% negative predictive value at a screen-positive rate of 11.4%. Only 9.8% (four of 41) of previas and low-lying placentas persisted through delivery. Transabdominal ultrasonography is an effective screening test for second-trimester placenta previa. At centers not performing universal transvaginal ultrasonography at the time of the anatomic survey, evidence-based transabdominal placenta-cervix distance cutoffs can optimize the identification of patients who require further surveillance for previa.
Allan, L. D.; Santos, R.; Pexieder, T.
1997-01-01
OBJECTIVES: To describe the normal cardiac morphology as seen by transvaginal ultrasound imaging in the first trimester fetus and to compare it with the morphology of the heart as seen by microdissection at the same gestational age. DESIGN: In 53 mothers undergoing early sonography, the fetal heart was examined and the images recorded. The gestational age range was 5-12 weeks of gestation, which represents 21 to 70 days after conception. Images were analysed frame by frame and compared with the anatomy of embryos and fetuses at the same gestational ages. RESULTS: After the 9th week of gestation, four cardiac chambers, the aortic origin, and the pulmonary artery could be identified on cross sectional echocardiography in conjunction with colour flow Doppler. At 9 weeks, the apex pointed anteriorly and the right ventricle and pulmonary artery lay to the right of the midline. By the 11th week of gestation, the apex pointed to the left and the pulmonary artery lay to the left of the midline as in the older fetus. Between 9 and 12 weeks' gestation the aorta was larger than the pulmonary artery. These findings were confirmed in the microdissected hearts. CONCLUSIONS: The current quality of ultrasound images obtained using transvaginal transducers in the first trimester fetus allows the study of fetal cardiac anatomy. Some of the later developmental changes can be demonstrated. As technology improves further the details of earlier cardiac morphogenesis may also become visible. Images PMID:9038698
Jiang, Jipeng; Liu, Ying; Wang, Kun; Wu, Xixiang; Tang, Ying
2017-09-07
The aim of study was to compare the accuracy between rectal water contrast transvaginal ultrasound (RWC-TVS) and double-contrast barium enema (DCBE) in evaluating the bowel endometriosis presence as well as its extent. 198 patients at reproductive age with suspicious bowel endometriosis were included. Physicians in two groups specialised at endometriosis performed RWC-TVS as well as DCBE before laparoscopy and both groups were blinded to other groups' results. Findings from RWC-TVS or DCBE were compared with histological results. The severity of experienced pain severity through RWC-TVS or DCBE was assessed by an analogue scale of 10 cm. In total, 110 in 198 women were confirmed to have endometriosis nodules in the bowel by laparoscopy as well as histopathology. For bowel endometriosis diagnosis, DCBE and RWC-TVS demonstrated sensitivities of 96.4% and 88.2%, specificities of 100% and 97.3%, positive prediction values of 100% and 98.0%, negative prediction values of 98.0% and 88.0%, accuracies of 98.0% and 92.4%, respectively. DCBE was related to more tolerance than RWC-TVS. RWC-TVS and DCBE demonstrated similar accuracies in the bowel endometriosis diagnosis; however, patients showed more tolerance for RWC-TVS than those with DCBE. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Guidelines for the management of vasa previa.
Gagnon, Robert
2009-08-01
To describe the etiology of vasa previa and the risk factors and associated condition, to identify the various clinical presentations of vasa previa, to describe the ultrasound tools used in its diagnosis, and to describe the management of vasa previa. Reduction of perinatal mortality, short-term neonatal morbidity, long-term infant morbidity, and short-term and long-term maternal morbidity and mortality. Published literature on randomized trials, prospective cohort studies, and selected retrospective cohort studies was retrieved through searches of PubMed or Medline, CINAHL, and the Cochrane Library, using appropriate controlled vocabulary (e.g., selected epidemiological studies comparing delivery by Caesarean section with vaginal delivery; studies comparing outcomes when vasa previa is diagnosed antenatally vs. intrapartum) and key words (e.g., vasa previa). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Searches were updated on a regular basis and incorporated into the guideline to October 1, 2008. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and from national and international medical specialty societies. The evidence collected was reviewed by the Diagnostic Imaging Committee and the Maternal Fetal Medicine Committee of the Society of Obstetricians and Gynaecologists of Canada (SOGC) and quantified using the evaluation of evidence guidelines developed by the Canadian Task Force on Preventive Health Care. The benefit expected from this guideline is facilitation of optimal and uniform care for pregnancies complicated by vasa previa. The Society of Obstetricians and Gynaecologists of Canada. A comparison of women who were diagnosed antenatally and those who were not shows respective neonatal survival rates of 97% and 44%, and neonatal blood transfusion rates of 3.4% and 58.5%, respectively. Vasa previa can be diagnosed antenatally, using combined abdominal and transvaginal ultrasound and colour flow mapping; however, many cases are not diagnosed, and not making such a diagnosis is still acceptable. Even under the best circumstances the false positive rate is extremely low. (II-2). 1. If the placenta is found to be low lying at the routine second trimester ultrasound examination, further evaluation for placental cord insertion should be performed. (II-2B) 2. Transvaginal ultrasound may be considered for all women at high risk for vasa previa, including those with low or velamentous insertion of the cord, bilobate or succenturiate placenta, or for those having vaginal bleeding, in order to evaluate the internal cervical os. (II-2B) 3. If vasa previa is suspected, transvaginal ultrasound colour Doppler may be used to facilitate the diagnosis. Even with the use of transvaginal ultrasound colour Doppler, vasa previa may be missed. (II-2B) 4. When vasa previa is diagnosed antenatally, an elective Caesarean section should be offered prior to the onset of labour. (II-1A) 5. In cases of vasa previa, premature delivery is most likely; therefore, consideration should be given to administration of corticosteroids at 28 to 32 weeks to promote fetal lung maturation and to hospitalization at about 30 to 32 weeks. (II-2B) 6. In a woman with an antenatal diagnosis of vasa previa, when there has been bleeding or premature rupture of membranes, the woman should be offered delivery in a birthing unit with continuous electronic fetal heart rate monitoring and, if time permits, a rapid biochemical test for fetal hemoglobin, to be done as soon as possible; if any of the above tests are abnormal, an urgent Caesarean section should be performed. (III-B) 7. Women admitted with diagnosed vasa previa should ideally be transferred for delivery in a tertiary facility where a pediatrician and blood for neonatal transfusion are immediately available in case aggressive resuscitation of the neonate is necessary. (II-3B) 8. Women admitted to a tertiary care unit with a diagnosis of vasa previa should have this diagnosis clearly identified on the chart, and all health care providers should be made aware of the potential need for immediate delivery by Caesarean section if vaginal bleeding occurs. (III-B).
A Short History of Sonography in Obstetrics and Gynaecology
Campbell, S.
2013-01-01
The history of sonography in Obstetrics and Gynaecology dates from the classic 1958 Lancet paper of Ian Donald and his team from Glasgow. Fifty years on it is impossible to conceive of practising Obstetrics and Gynaecology without one of the many forms of ultrasound available today. Technological developments such as solid state circuitry, real time imaging, colour and power Doppler, transvaginal sonography and 3/4D imaging have been seized by clinical researchers to enhance the investigation and management of patients in areas as diverse as assessment of fetal growth and wellbeing, screening for fetal anomalies, prediction of pre-eclampsia and preterm birth, detection of ectopic gestation, evaluation of pelvic masses, screening for ovarian cancer and fertility management. Ultrasound guided procedures are now essential components of fetal therapy and IVF treatment. This concise history is written by someone who has witnessed each of these advances throughout the ultrasound era and is able to give perspective to these momentous happenings. PMID:24753947
Toward in-vivo photoacoustic imaging of human ovarian tissue for cancer detection
NASA Astrophysics Data System (ADS)
Aguirre, Andres; Kumavor, Patrick; Ardeshirpour, Yasaman; Sanders, Mary M.; Brewer, Molly; Zhu, Quing
2011-03-01
Currently, most of the cancers in the ovary are detected when they have already metastasized to other parts of the body. As a result, ovarian cancer has the highest mortality of all gynecological cancers with a 5-year survival rate of 30% or less [1]. The reason is the lack of reliable symptoms as well as the lack of efficacious screening techniques [2,3]. Thus, there is an urgent need to improve the current diagnostic techniques. We have investigated the potential role of co-registered photoacoustic and ultrasound imaging in ovarian cancer detection. In an effort to bring this technique closer to clinical application, we have developed a co-registered ultrasound and photoacoustic transvaginal probe. A fiber coupling assembly has been developed to deliver the light from around the transducer for reflection geometry imaging. Co-registered ultrasound and photoacoustic images of swine ovaries through vagina wall muscle and human ovaries using the aforementioned probe, demonstrate the potential of photoacoustic imaging to non-invasively detect ovarian cancer in vivo.
Endometrial Receptivity and its Predictive Value for IVF/ICSI-Outcome
Heger, A.; Sator, M.; Pietrowski, D.
2012-01-01
Endometrial receptivity plays a crucial role in the establishment of a healthy pregnancy in cycles of assisted reproduction. The endometrium as a key factor during reproduction can be assessed in multiple ways, most commonly through transvaginal grey-scale or 3-D ultrasound. It has been shown that controlled ovarian hyperstimulation has a great impact on the uterine lining, which leads to different study results for the predictive value of endometrial factors measured on different cycle days. There is no clear consensus on whether endometrial factors are appropriate to predict treatment outcome and if so, which one is suited best. The aim of this review is to summarize recent findings of studies about the influence of endometrial thickness, volume and pattern on IVF- and ICSI-treatment outcome and provide an overview of future developments in the field. PMID:25258462
Endometrial Receptivity and its Predictive Value for IVF/ICSI-Outcome.
Heger, A; Sator, M; Pietrowski, D
2012-08-01
Endometrial receptivity plays a crucial role in the establishment of a healthy pregnancy in cycles of assisted reproduction. The endometrium as a key factor during reproduction can be assessed in multiple ways, most commonly through transvaginal grey-scale or 3-D ultrasound. It has been shown that controlled ovarian hyperstimulation has a great impact on the uterine lining, which leads to different study results for the predictive value of endometrial factors measured on different cycle days. There is no clear consensus on whether endometrial factors are appropriate to predict treatment outcome and if so, which one is suited best. The aim of this review is to summarize recent findings of studies about the influence of endometrial thickness, volume and pattern on IVF- and ICSI-treatment outcome and provide an overview of future developments in the field.
Tan, Shu-Yin; Hang, Fu; Purvarshi, Gowreesunkur; Li, Min-Qing; Meng, Da-Hua; Huang, Ling-Ling
2015-10-01
To evaluate the predictive value of three-dimensional (3D)-power Doppler sonography on recurrent miscarriage. The study patients were divided into a recurrent miscarriage group (30 cases) and a normal pregnancy group (21 cases). Measurement of endometrial thickness was performed using two-dimensional transvaginal ultrasound in the midluteal phase. The endometrial volume, vascularization index (VI), flow index (FI), and vascularization-flow index (VFI) in midluteal and placenta volume, as well as the VI, FI, and VFI of early pregnancy were measured using Virtual Organ Computer-aided Analysis of 3D-power Doppler ultrasound. Endometrial thickness, endometrial volume, endometrial vascular data, VI, FI, and VFI of the midluteal phase were lower in the recurrent miscarriage group compared with the normal pregnancy group (p < 0.05). Placental volume, VI, and VFI during early pregnancy were lower in the miscarriage group compared with the normal pregnancy group (p < 0.05). There was no significant change in FI between the recurrent miscarriage and control groups during early pregnancy (p > 0.05). The predictive accuracy of endometrial thickness, endometrial volume, VI, FI, and VFI in the midluteal phase, and placenta volume, VI, FI, and VFI in early pregnancy as measured by the receiver operating characteristic curve to predict miscarriage before 12 gestational weeks in participants was 0.681, 0.876, 0.770, 0.720, 0.879, 0.771, 0.907, 0.592, respectively. The 3D-power Doppler ultrasound is a more comprehensive and sensitive method for evaluating endometrial receptivity. Endometrial volume, VI, FI, and VFI in the midluteal phase, as well as VI in early pregnancy, can be considered as predictive factors for recurrent miscarriage. Copyright © 2015. Published by Elsevier B.V.
Vaginal gamete intrafallopian transfer. Experience with 14 cases.
Lucena, E; Paulson, J D; Ruiz, J; Asmar, P; Mendoza, J C; Ortiz, J A; Gomez, M; Arango, A; Lucena, C; Lucena, A
1990-06-01
A procedure utilizing transvaginal aspiration of stimulated gametes followed by transcervical, ultrasound-guided catheterization of the tubal ostia was performed as a modification of the standardized gamete intrafallopian transfer (GIFT) technique. Among 14 patients with 16 cycles there were four normal, intrauterine pregnancies and one ectopic pregnancy. In two patients the beta-human gonadotropin level rose significantly and then started to fall; the patients aborted spontaneously. The procedure can be performed with a higher degree of patient acceptance than can traditional GIFT, and the success rate in this small series was promising.
NASA Astrophysics Data System (ADS)
Alqasemi, Umar; Li, Hai; Yuan, Guangqian; Kumavor, Patrick; Zanganeh, Saeid; Zhu, Quing
2014-07-01
Coregistered ultrasound (US) and photoacoustic imaging are emerging techniques for mapping the echogenic anatomical structure of tissue and its corresponding optical absorption. We report a 128-channel imaging system with real-time coregistration of the two modalities, which provides up to 15 coregistered frames per second limited by the laser pulse repetition rate. In addition, the system integrates a compact transvaginal imaging probe with a custom-designed fiber optic assembly for in vivo detection and characterization of human ovarian tissue. We present the coregistered US and photoacoustic imaging system structure, the optimal design of the PC interfacing software, and the reconfigurable field programmable gate array operation and optimization. Phantom experiments of system lateral resolution and axial sensitivity evaluation, examples of the real-time scanning of a tumor-bearing mouse, and ex vivo human ovaries studies are demonstrated.
A case report of vasa previa incidentally discovered
Saghir, Salahiddine; Kouach, Jaouad; Agadr, Aomar
2015-01-01
Vasa previa is a rare but clinically important obstetrical complication that can be associated with a low-lying placenta or placenta previa. We aim to present one case of vasa previa diagnosed during the placenta examination after the caesarean indicated for triple uterus scar. A 26-year-old female was referred to our hospital at 30 weeks of gestation to provide a scheduled caesarean. Trans-abdominal ultrasound was performed; the placenta was positioned in the posterior side of the fundus. Fetal growth was found to be appropriate for gestational age. A healthy male infant weighing was successfully delivered via cesarean section at 38 weeks of gestation. This operation helped to prevent complications due to acute fetal bleeding. The identification and exclusion of vasa previa using trans-vaginal ultrasound are essential to ensure appropriate and timely treatment. PMID:26405470
Bamberg, Christian; Hinkson, Larry; Dudenhausen, Joachim W; Bujak, Verena; Kalache, Karim D; Henrich, Wolfgang
2017-12-01
Cesarean deliveries are the most common abdominal surgery procedure globally, and the optimal way to suture the hysterotomy remains a matter of debate. The aim of this study was to assess the incidence of cesarean scar niches and the depth after single- or double-layer uterine closure. We performed a randomized controlled trial in which women were allocated to three uterotomy suture techniques: continuous single-layer unlocked, continuous locked single-layer, or double-layer sutures. Transvaginal ultrasound was performed six weeks and 6-24 months after cesarean delivery [Clinicaltrials.gov (NCT02338388)]. The study included 435 women. Six weeks after delivery, the incidence of niche was not significantly different between the groups (p = 0.52): 40% for single-layer unlocked, 32% for single-layer locked and 43% for double-layer sutures. The mean ± SD niche depths were 3.0 ± 1.4 mm for single-layer unlocked, 3.6 ± 1.7 mm for single-layer locked and 3.3 ± 1.3 mm for double-layer sutures (p = 1.0). There were no significant differences (p = 0.58) in niche incidence between the three groups at the second ultrasound follow up: 30% for single-layer unlocked, 23% for single-layer locked and 29% for double-layer sutures. The mean ± SD niche depth was 3.1 ± 1.5 mm after single-layer unlocked, 2.8 ± 1.5 mm after single-layer locked and 2.5 ± 1.2 mm after double-layer sutures (p = 0.61). There was a trend (p = 0.06) for the residual myometrium thickness to be thicker after double-layer repair at the long-term follow up. The incidence of cesarean scar niche formation and the niche depth was independent of the hysterotomy closure technique. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.
Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Adur, Malavika K; Utterback, Chet W; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S
2015-01-01
Limited resolution of transvaginal ultrasound (TVUS) scanning is a significant barrier to early detection of ovarian cancer (OVCA). Contrast agents have been suggested to improve the resolution of TVUS scanning. Emerging evidence suggests that expression of interleukin 16 (IL-16) by the tumor epithelium and microvessels increases in association with OVCA development and offers a potential target for early OVCA detection. The goal of this study was to examine the feasibility of IL-16-targeted contrast agents in enhancing the intensity of ultrasound imaging from ovarian tumors in hens, a model of spontaneous OVCA. Contrast agents were developed by conjugating biotinylated anti-IL-16 antibodies with streptavidin coated microbubbles. Enhancement of ultrasound signal intensity was determined before and after injection of contrast agents. Following scanning, ovarian tissues were processed for the detection of IL-16 expressing cells and microvessels. Compared with precontrast, contrast imaging enhanced ultrasound signal intensity significantly in OVCA hens at early (P < 0.05) and late stages (P < 0.001). Higher intensities of ultrasound signals in OVCA hens were associated with increased frequencies of IL-16 expressing cells and microvessels. These results suggest that IL-16-targeted contrast agents improve the visualization of ovarian tumors. The laying hen may be a suitable model to test new imaging agents and develop targeted anti-OVCA therapeutics.
Ultrasound diagnostic of mesonephric paraovarian cyst - case report
Bohîlțea, RE; Cîrstoiu, MM; Turcan, N; Ionescu, CA
2016-01-01
Paraovarian cysts are a rare pathology, constituting 10-20% of the adnexal masses. The origin can be represented by paramesonephric ducts (Hydatid cysts of Morgagni), vestiges of mesonephric ducts also represented by mesothelium, or neoplastic (cystadenomas or cystadenofibromas) that are mostly benign. Borderline or malignant paraovarian tumors are encountered less often. This article presents a case of paraovarian cyst in a 37-year-old patient, with a history of 2 pregnancies, completed by cesarean. The patient sought medical attention for an asymptomatic voluminous ovarian cyst, detected in a routine ultrasound scan. Laboratory tests and tumor markers were within normal limits. Transvaginal ultrasound and color Doppler revealed a cystic adnexal mass with 10 cm transonic, smooth, homogeneous content, avascular walls with no internal papillary projections, with a “hyperechoic line” sign of delimitation from the ovarian capsule, mostly visible when the adnexa was mobilized. The diagnostic and curative laparoscopic surgery was successful, followed by a quick recovery. The histopathological exam confirmed the benignity and the origin of the paraovarian cyst. The case was discussed in the context of the literature review concerning this pathology, drawing attention to the real possibility of differentiating ovarian from paraovarian cysts by ultrasound. PMID:27974934
Early Evaluation of the Fetal Heart.
Hernandez-Andrade, Edgar; Patwardhan, Manasi; Cruz-Lemini, Mónica; Luewan, Suchaya
2017-01-01
Evaluation of the fetal heart at 11-13 + 6 weeks of gestation is indicated for women with a family history of congenital heart defects (CHD), a previous child with CDH, or an ultrasound finding associated with cardiac anomalies. The accuracy for early detection of CHD is highly related to the experience of the operator. The 4-chamber view and outflow tracts are the most important planes for identification of an abnormal heart, and can be obtained in the majority of fetuses from 11 weeks of gestation onward. Transvaginal ultrasound is the preferred route for fetal cardiac examination prior to 12 weeks of gestation, whereas, after 12 weeks, the fetal heart can be reliably evaluated by transabdominal ultrasound. Cardiac defects, such as ventricular septal defects, tetralogy of Fallot, Ebstein's anomaly, or cardiac tumors, are unlikely to be identified at ≤14 weeks of gestation. Additional ultrasound techniques such as spatiotemporal image correlation and the evaluation of volumes by a fetal-heart expert can improve the detection of congenital heart disease. The evaluation of the fetal cardiac function at 11-13 + 6 weeks of gestation can be useful for early identification of fetuses at risk of anemia due to hemoglobinopathies, such as hemoglobin Bart's disease. © 2017 S. Karger AG, Basel.
Aiyappan, Senthil Kumar; Karpagam, Bulabai; Vadanika, V; Chidambaram, Prem Kumar; Vinayagam, S; Saravanan, K C
2016-01-01
Antral Follicle count (AFC) is a reliable marker for ovarian reserve. Previous studies have used transvaginal ultrasound for estimation of AFC, however we used magnetic resonance imaging (MRI) for estimation of AFC and for creating an age-related normogram in patients with polycystic ovary syndrome (PCOS) and compared it with normal patients. The aim of this study is to create an age related normogram for AFC in women with PCOS and to compare that with women without polycystic ovarian syndrome using MRI. A total of 1500 women were examined, out of which 400 fitted the criteria for PCOS. They all underwent MRI study and similar age matched women without PCOS also underwent MRI examination. Normogram for AFC were obtained using LMS software and a percentile chart was obtained. Normogram for AFC in PCOS women showed decline in number of AFC as the age progresses and the decline was linear. The normogram for AFC was compared with equal number of patients without PCOS and they also showed decline in AFC as the age progresses, however the decline was exponential and faster. Age related normogram for AFC is widely used and considered as best clinical predictor for ovarian response in assisted reproductive technology. Knowledge of ovarian reserve is important in PCOS and non-PCOS females as PCOS patients are at risk for ovarian hyperstimulation syndrome during gonadotrophin theraphy. MRI is an equally effective and in some times better alternative to transvaginal ultrasound as it has got its own advantages.
2011-01-01
Background We assessed ovarian cancer screening outcomes in women with a positive family history of ovarian cancer divided into a low-, moderate- or high-risk group for development of ovarian cancer. Methods 545 women with a positive family history of ovarian cancer referred to the Ovarian Screening Service at the Royal Marsden Hospital, London from January 2000- December 2008 were included. They were stratified into three risk-groups according to family history (high-, moderate- and low-risk) of developing ovarian cancer and offered annual serum CA 125 and transvaginal ultrasound screening. The high-risk group was offered genetic testing. Results The median age at entry was 44 years. The number of women in the high, moderate and low-risk groups was 397, 112, and 36, respectively. During 2266 women years of follow-up two ovarian cancer cases were found: one advanced stage at her fourth annual screening, and one early stage at prophylactic bilateral salpingo-oophorectomy (BSO). Prophylactic BSO was performed in 138 women (25.3%). Forty-three women had an abnormal CA125, resulting in 59 repeat tests. The re-call rate in the high, moderate and low-risk group was 14%, 3% and 6%. Equivocal transvaginal ultrasound results required 108 recalls in 71 women. The re-call rate in the high, moderate, and low-risk group was 25%, 6% and 17%. Conclusion No early stage ovarian cancer was picked up at annual screening and a significant number of re-calls for repeat screening tests was identified. PMID:22112691
Dual-mode photoacoustic and ultrasound system for real-time in-vivo ovarian cancer imaging
NASA Astrophysics Data System (ADS)
Mostafa, Atahar; Nandy, Sreyankar; Amidi, Eghbal; Zhu, Quing
2018-02-01
More than 80% of the ovarian cancers are diagnosed at late stages and the survival rate is less than 50%. Currently, there is no effective screening technique available and transvaginal US can only tell if the ovaries are enlarged or not. We have developed a new real-time co-registered US and photoacoustic system for in vivo imaging and characterization of ovaries. US is used to localize ovaries and photoacoustic imaging provides functional information about ovarian tissue angiogenesis and oxygenation saturation. The system consists of a tunable laser and a commercial US system from Alpinion Inc. The Alpinion system is cable of providing channel data for both US pulse-echo and photoacoustic imaging and can be programmed as a computer terminal for display US and photoacoustic images side by side or in coregistered mode. A transvaginal ultrasound probe of 6-MHz center frequency and bandwidth of 3-10 MHz is coupled with four optical fibers surrounded the US probe to deliver the light to tissue. The light from optical fibers is homogenized to ensure the power delivered to the tissue surface is below the FDA required limit. Physicians can easily navigate the probe and use US to look for ovaries and then turn on photoacoustic mode to provide real-time tumor vasculature and So2 saturation maps. With the optimized system, we have successfully imaged first group of 7 patients of malignant, abnormal and benign ovaries. The results have shown that both photoacoustic signal strength and spatial distribution are different between malignant and abnormal and benign ovaries.
Towards BirthAlert—A Clinical Device Intended for Early Preterm Birth Detection
Etemadi, Mozziyar; Chung, Philip; Heller, J. Alex; Liu, Jonathan A.; Rand, Larry; Roy, Shuvo
2015-01-01
Preterm birth causes 1 million infant deaths worldwide every year, making it the leading cause of infant mortality. Existing diagnostic tests such as transvaginal ultrasound or fetal fibronectin either cannot determine if preterm birth will occur in the future or can only predict the occurrence once cervical shortening has begun, at which point it is too late to reverse the accelerated parturition process. Using iterative and rapid prototyping techniques, we have developed an intravaginal proof-of-concept device that measures both cervical bioimpedance and cervical fluorescence to characterize microstructural changes in a pregnant woman's cervix in hopes of detecting preterm birth before macroscopic changes manifest in the tissue. If successful, such an early alert during this “silent phase” of the preterm birth syndrome may open a new window of opportunity for interventions that may reverse and avoid preterm birth altogether. PMID:23893706
Otsuki, Edney Norio; Oliveira, Emerson; Sartori, Marair Gracio Ferreira; Girão, Manoel João Batista Castelo; Jármy-Di Bella, Zsuzsanna Ilona Katalin
2014-01-01
Objective. To compare bladder wall thickness in two kinds of urinary incontinent women—stress urinary incontinence (SUI) and overactive bladder (OAB) with urodynamic detrusor overactivity (DO), and to compare them with continent patients by ultrasound, also, correlate with cystometric results in incontinent women. Methods. 91 women were divided into the following groups: continent (n = 31), SUI (n = 30), and DO (n = 30) groups after clinical evaluation and urodynamic test (only in incontinent women). Transvaginal ultrasound was performed to the bladder wall thickness (BWT) measurement. The mean of BWT was calculated and data were analyzed with ANOVA and Turkey's multiple comparison tests. Pearson's correlation coefficient (r) was used to compare two variables. Receiver operating characteristic (ROC) curve was performed to study BWT as a diagnostic parameter. Results. BWT in DO group was significantly higher than that in the other groups (P < 0.005). A moderate positive correlation was found between BWT and maximum bladder pressure during involuntary bladder contraction. There was no difference in BWT between SUI and continent groups. DO group had lower first desire to void and cystometric capacity. Maximum bladder pressure at detrusor contraction had a moderate positive correlation with BWT. The ROC revealed an area under the curve of 0.962 (95% CI, 0.90–1.01). Conclusions. DO patients have increased bladder wall thickness, lower first desire to void, and lower cystometric capacity. There was a moderate correlation between BWT and maximum bladder pressure during involuntary bladder contraction. PMID:25538959
Radiology of benign disorders of menstruation.
Griffin, Yvette; Sudigali, Venkat; Jacques, Audrey
2010-10-01
Menstrual complaints are common and include pain, abnormal bleeding, and menstrual irregularity. The etiology is wide-ranging and includes endometriosis, fibroids, adenomyosis, pelvic congestion syndrome, pelvic inflammatory disease, endometrial hyperplasia, and polyps. Polycystic ovarian syndrome and some congenital uterine anomalies may present with menstrual disturbance and have been included in this review. Transvaginal ultrasound is widely used as first-line investigation. Magnetic resonance imaging is used increasingly with high diagnostic accuracy and confidence. Its multiplanar capacity and superior tissue contrast resolution enable accurate presurgical mapping of fibroids, deep pelvic endometriosis, and adenomyosis. Similarly, accurate differentiation of congenital uterine anomalies depends on multiplanar imaging with either 3-dimensional ultrasound or magnetic resonance imaging. Recent advances in imaging and radiological intervention, combined with an understanding of the underlying causes of menstrual dysfunction, therefore aid in accurate diagnosis and optimal treatment planning. Copyright © 2010 Elsevier Inc. All rights reserved.
Park, Kyo Hoon
2007-08-01
The aim of this study was to evaluate the value of transvaginal sonographic cervical measurement in predicting failed labor induction and cesarean delivery for failure to progress in nulliparous women. One hundred and sixty-one women scheduled for labor induction underwent transvaginal ultrasonography and digital cervical examinations. Logistic regression demonstrated that cervical length and gestational age at induction, but not the Bishop score, significantly and independently predicted failed labor induction. According to the receiver operating characteristic curves analysis, the best cut-off value of cervical length for predicting failed labor induction was 28 mm, with a sensitivity of 62% and a specificity of 60%. In terms of the likelihood of a cesarean delivery for failure to progress as the outcome variable, logistic regression indicated that maternal height and birth weight, but not cervical length or Bishop score, were significantly and independently associated with an increased risk of cesarean delivery for failure to progress. Transvaginal sonographic measurements of cervical length thus independently predicted failed labor induction in nulliparous women. However, the relatively poor predictive performance of this test undermines its clinical usefulness as a predictor of failed labor induction. Moreover, cervical length appears to have a poor predictive value for the likelihood of a cesarean delivery for failure to progress.
Marschke, J; Hengst, L; Schwertner-Tiepelmann, N; Beilecke, K; Tunn, R
2015-05-01
Single-incision transvaginal mesh for reconstruction of Level I and II prolapses in women with recurrent or advanced prolapse. We evaluated functional, anatomical, sonomorphological and quality-of-life outcome. Data were collected retrospectively for preoperative parameters and at follow-up visits. Anatomical cure was assessed with vaginal examination using the ICS-POP-Q system; introital-ultrasound scan for postvoidal residual and description of mesh characteristics was performed. We applied a visual analogue scale (VAS) and the German Pelvic Floor Questionnaire to assess quality-of-life. Seventy women with cystocele (III: 61.3%/IV: 16%), all post-hysterectomy and in majority (81.4%) after previous cystocele repair, were operated using a single-incision transvaginal technique. Overall anatomical success rate was 95.7% with significant improvement in quality-of-life (p < 0.0001). Mesh erosion occurred in 5.7%, one patient presented symptomatic vaginal vault prolapse. Postvoidal residual declined significantly (58 vs. 2.9%). Sonographic mesh length was 55.7% of implanted mesh with a wide range of mesh position, but no signs of mesh dislocation. There was no de novo dyspareunia reported, one case of preoperative existing dyspareunia worsened. No severe adverse event was observed. We hereby present a trial of a high-risk group of patients requiring reconstruction of anterior and apical vaginal wall in mostly recurrent prolapse situation. Our data support the hypothesis of improved anatomical and functional results and less mesh shrinkage caused by the single-incision technique with fixation in sacrospinous ligament in combination with modification in mesh quality compared to former multi-incision techniques.
Paraurethral Leiomyoma in a Postmenopausal Woman: First European Case
Borg, Camilla Skovvang; Majeed, Huda Galib; Humaidan, Peter
2015-01-01
Leiomyomas are benign tumors extending from smooth muscle cells and only few cases of paraurethral leiomyomas have been described in the literature. They are often seen in the reproductive age and around 50% of the cases are asymptomatic. We describe a 59-year-old woman with a solid mobile tumor below the symphysis revealed at a gynecological examination. Transvaginal ultrasound and MRI confirmed the tumor and excision of the paraurethral tumor was carried out. The histological examination showed a benign paraurethral leiomyoma. The postoperative period was characterized by urethral pain as well as vaginal leakage of urine. PMID:25878911
Wani, N A; Skidmore, J A
2010-08-01
In Experiment 1, studies were conducted to apply the transvaginal ultrasound guided ovum pick-up (OPU) technique in dromedary camels after their ovarian super-stimulation and in vivo oocyte maturation. In Experiment 2, the developmental potential of two commonly used oocyte types, i.e., in vivo matured oocytes collected by OPU and abattoir derived in vitro-matured oocytes was compared after their chemical activation. In Experiment 3, developmental competence of oocytes collected from super-stimulated camels by OPU, matured either in vivo or in vitro, was compared after their chemical activation. Mature female dromedary camels super-stimulated with a combination of eCG and pFSH were given an injection of 20 microg of the GnRH analogue, buserelin 24, 26, or 28 h before the scheduled OPU. For collection of cumulus oocyte complexes (COCs) the transducer was guided through the vulva into the cranial most portion of the vagina and 17-gauge, 55 cm single-lumen needle was placed in the needle guide of the ultrasound probe and advanced through the vaginal fornix and into the follicle. Follicular fluid was aspirated using a regulated vacuum pump into tubes containing embryo-flushing media. Aspirates were searched for COCs using a stereomicroscope, and they were then denuded of cumulus cells by hyaluronidase and repeated pipetting. The oocytes were classified as mature (with a visible polar body), immature (with no visible polar body), activated (with divided or fragmented ooplasm) and others (degenerated and abnormal). Overall an average of 12.12 +/- 7.9 COCs were aspirated per animal with an oocyte recovery rate from the aspirated follicles of about 77%. The majority (> 90%) of the collected COCs by OPU were with loose and expanded cumulus cells. The proportion of matured oocytes obtained at 28-29 h (91.2 +/- 4.1) and 26-27 h (82.1 +/- 3.4) were higher (P < 0.005) when compared with those obtained at 24-25 h (40.4 +/- 16.3) after GnRH administration. In Experiment 2, a higher proportion (P < 0.05) of in vivo matured oocytes cleaved (84.6 +/- 2.1 vs. 60.9 +/- 6.6) and developed to blastocyst stages (52.4 +/- 4.1 vs. 30.5 +/- 3.3) when compared with in vitro matured oocytes collected from slaughterhouse ovaries. In Experiment 3, no difference was observed between the developmental competences of oocytes, collected from super stimulated camels, matured in vitro with those collected after their in vivo maturation. In conclusion, about 80-90% mature oocytes can be collected by ultrasound guided transvaginal ovum pick-up from super-stimulated dromedary camels 26-28 h after GnRH administration. The developmental response, to chemical activation, of in vivo matured oocytes collected by ultrasound guided transvaginal OPU is better than in vitro matured oocytes obtained from slaughterhouse ovaries. However, no difference was observed in the developmental competence of oocytes collected by OPU whether they were matured in vivo or in vitro. Copyright 2010 Elsevier Inc. All rights reserved.
Single point biochemical measurement algorithm for early diagnosis of ectopic pregnancy.
Butler, Stephen A; Abban, Thomas K A; Borrelli, Paola T A; Luttoo, Jameel M; Kemp, Bryn; Iles, Ray K
2013-09-01
Tubal rupture as a result of an ectopic pregnancy is the leading cause of first trimester maternal mortality. Currently, the diagnosis of ectopic pregnancy depends on transvaginal ultrasound and serial serum measurements of human chorionic gonadotrophin (hCG), which requires follow up. The objective of this study was to examine whether single point measurements at presentation could distinguish between women with ectopic pregnancy, viable pregnancy, and spontaneous miscarriage. Serum total hCG (hCGt), hyperglycosylated hCG (hCGh), free beta subunit of hCG (hCGβ), progesterone (P), and CA-125 were measured by chemiluminescence immunoassay over a 3 month period in 441 women presenting at the emergency room with abdominal pain and a positive pregnancy test. Patient outcomes were followed and confirmed by histology. 65 samples were excluded due to poor sample storage, or lost to follow up. The pregnancy outcomes were 175 viable pregnancies, 175 spontaneous miscarriages, and 26 ectopic pregnancies. A serum hCGt <3736 mIU/mL cut off was 100% sensitive, with 76% specificity, for distinguishing ectopic pregnancy from viable pregnancy; but did not differentiate spontaneous miscarriage. Serum CA125 <41.98 U/mL produced 100% sensitivity and 43% specificity in distinguishing ectopic pregnancy from spontaneous miscarriage. Sequential application of hCGt and CA-125 cut off followed by ultrasound could detect 100% of ectopic pregnancies with 87% specificity for all intrauterine pregnancies. The combination of serum hCGt <3736 mIU/mL, followed by CA125 <41.98 U/mL is a promising algorithm for detecting all ectopic pregnancy at initial presentation. © 2013.
Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.
Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H
2017-12-01
Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound-guided, local MTX injection is apparently effective for the treatment of CP without the need for concomitant procedures or surgical intervention. Furthermore, this conservative technique both preserves fertility and allows for the possibility of subsequent uneventful pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates
2015-10-01
The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.
Bronshtein, Moshe; Solt, Ido; Blumenfeld, Zeev
2014-06-01
Despite more than three decades of universal popularity of fetal sonography as an integral part of pregnancy evaluation, there is still no unequivocal agreement regarding the optimal dating of fetal sonographic screening and the type of ultrasound (transvaginal vs abdominal). TransvaginaL systematic sonography at 14-17 weeks for fetal organ screening. The evaluation of over 72.000 early (14-17 weeks) and late (18-24 weeks) fetal ultrasonographic systematic organ screenings revealed that 96% of the malformations are detectable in the early screening with an incidence of 1:50 gestations. Only 4% of the fetal anomalies are diagnosed later in pregnancy. Over 99% of the fetal cardiac anomalies are detectable in the early screening and most of them appear in low risk gestations. Therefore, we suggest a new platform of fetal sonographic evaluation and follow-up: The extensive systematic fetal organ screening should be performed by an expert sonographer who has been trained in the detection of fetal malformations, at 14-17 weeks gestation. This examination should also include fetal cardiac echography Three additional ultrasound examinations are suggested during pregnancy: the first, performed by the patient's obstetrician at 6-7 weeks for the exclusion of ectopic pregnancy, confirmation of fetal viability, dating, assessment of chorionicity in multiple gestations, and visualization of maternal adnexae. The other two, at 22-26 and 32-34 weeks, require less training and should be performed by an obstetrician who has been qualified in the sonographic detection of fetal anomalies. The advantages of early midtrimester targeted fetal systematic organ screening for the detection of fetal anomalies may dictate a global change.
Yao, Min; Wang, Wenjing; Zhou, Jieru; Sun, Minghua; Zhu, Jialiang; Chen, Pin; Wang, Xipeng
2017-04-01
This study was conducted to determine a more accurate imaging method for the diagnosis of cesarean scar diverticulum (CSD) and to identify the parameters of CSD strongly associated with prolonged menstrual bleeding. We enrolled 282 women with a history of cesarean section (CS) who presented with prolonged menstrual bleeding between January 2012 and May 2015. Transvaginal ultrasound, general magnetic resonance imaging (MRI) and contrast-enhanced MRI were used to diagnose CSD. Five parameters were compared among the imaging modalities: length, width, depth and thickness of the remaining muscular layer (TRM) of CSD and the depth/TRM ratio. Correlation between the five parameters and days of menstrual bleeding was performed. Finally, multivariate analysis was used to determine the parameters associated with menstrual bleeding longer than 14 days. Contrast-enhanced MRI yielded greater length or width or thinner TRM of CSD compared with MRI and transvaginal ultrasound. CSD size did not significantly differ between women who had undergone one and two CSs. Correlation analysis revealed that CSD (P = 0.038) and TRM (P = 0.003) lengths were significantly associated with days of menstrual bleeding. Longer than 14 days of bleeding was defined by cut-off values of 2.15 mm for TRM and 13.85 mm for length. TRM and number of CSs were strongly associated with menstrual bleeding longer than 14 days. CE-MRI is a relatively accurate and efficient imaging method for the diagnosis of CSD. A cut-off value of TRM of 2.15 mm is the most important parameter associated with menstrual bleeding longer than 14 days. © 2017 Japan Society of Obstetrics and Gynecology.
Briggs, Brandi N; Stender, Michael E; Muljadi, Patrick M; Donnelly, Meghan A; Winn, Virginia D; Ferguson, Virginia L
2015-06-25
Clinical practice requires improved techniques to assess human cervical tissue properties, especially at the internal os, or orifice, of the uterine cervix. Ultrasound elastography (UE) holds promise for non-invasively monitoring cervical stiffness throughout pregnancy. However, this technique provides qualitative strain images that cannot be linked to a material property (e.g., Young's modulus) without knowledge of the contact pressure under a rounded transvaginal transducer probe and correction for the resulting non-uniform strain dissipation. One technique to standardize elastogram images incorporates a material of known properties and uses one-dimensional, uniaxial Hooke's law to calculate Young's modulus within the compressed material half-space. However, this method does not account for strain dissipation and the strains that evolve in three-dimensional space. We demonstrate that an analytical approach based on 3D Hertzian contact mechanics provides a reasonable first approximation to correct for UE strain dissipation underneath a round transvaginal transducer probe and thus improves UE-derived estimates of tissue modulus. We validate the proposed analytical solution and evaluate sources of error using a finite element model. As compared to 1D uniaxial Hooke's law, the Hertzian contact-based solution yields significantly improved Young's modulus predictions in three homogeneous gelatin tissue phantoms possessing different moduli. We also demonstrate the feasibility of using this technique to image human cervical tissue, where UE-derived moduli estimations for the uterine cervix anterior lip agreed well with published, experimentally obtained values. Overall, UE with an attached reference standard and a Hertzian contact-based correction holds promise for improving quantitative estimates of cervical tissue modulus. Copyright © 2015 Elsevier Ltd. All rights reserved.
Design of an everting balloon to deploy a microendoscope to the fallopian tubes
NASA Astrophysics Data System (ADS)
Keenan, Molly; Howard, Caitlin; Tate, Tyler; McGuiness, Ian; Sauer-Budge, Alexis; Black, John; Utzinger, Urs; Barton, Jennifer K.
2016-02-01
The 5-year survival rate for ovarian cancer is only 45% largely due to lack of effective screening methods. Current methods include palpation, transvaginal ultrasound, and the CA-125 blood test. Finding disease reliably and at an early stage increase survival to 92%. We have designed and built a 0.7 mm endoscope for the early detection of ovarian cancer. Inserted transvaginally through the working channel of a hysteroscope, the falloposcope creates a minimally invasive procedure for the screening of high risk women. To improve the ease-of-use and safety of falloposcope deployment, we are working to create an everting balloon. Currently, the falloposcope would require a skilled user to operate due to the challenging anatomy of the fallopian tubes - a small opening from the uterus (< 1 mm), tortuous path, and delicate lumenal features. A balloon delivery system would gently open the fallopian tube and guide the falloposcope down the center of lumen. We show balloon design and discuss integration with the falloposcope prototype. We test possible mechanical damage to the tissue due to scraping, puncture, or overstretching. Successful introduction of the everting balloon to simplify falloposcope delivery could expand screening beyond specialized centers to smaller clinical locations.
Comparison of transabdominal and transvaginal sonography in the diagnosis of placenta previa.
Petpichetchian, Chusana; Pranpanus, Savitree; Suntharasaj, Thitima; Kor-Anantakul, Ounjai; Hanprasertpong, Tharangrut
2018-07-01
To compare the accuracies of transabdominal sonography (TAS) and transvaginal sonography (TVS) in the diagnosis of placenta previa. A prospective, cross-sectional study was conducted at a university hospital. Both TAS and TVS were performed on 81 pregnant women with a suspicion of placenta previa in the third trimester. The final diagnosis was confirmed at delivery. The agreement between the two ultrasound methods and the parameters of each method were calculated. Fifty-eight percent of the women had a placenta previa. The sensitivities of TAS and TVS were 86% (95% CI 78-94%) and 95% (95% CI 91-100%), respectively (p= 0.2). The specificity of both methods was 93% (95 CI 88-99%), and the overall accuracies of TAS and TVS were 89% (95% CI 82-96%) and 94% (95% CI 89-100%), respectively. When TAS was followed by TVS, 23% of the previous diagnoses were changed. The agreement between both methods was good (Kappa value = 0.7, 95%CI 0.55-0.86). For the diagnosis of placenta previa, TAS showed a high sensitivity and specificity, which were comparable to those of TVS. © 2018 Wiley Periodicals, Inc.
Häggström, Mikael; Spira, Jack; Edelstam, Greta
2015-02-01
To determine whether current hygiene practices are appropriate during sonographic examinations. Five major hospitals in Sweden were investigated with a survey. At each hospital, the departments corresponding to the main types of sonographic examination were chosen. Personnel who were responsible for or acquainted with the local hygiene procedures completed a standardardized questionnaire. The surveys were completed by 25 departments, where the total number of sonographic examinations was approximately 20,000 per month. For transvaginal and transrectal sonographic examinations, the most common method for decontamination of the transducer was barrier protection during the procedure followed by cleansing with alcohol. Latex was the predominant cover material, but one department used polyethylene gloves, and another department used nitrile gloves. Both of these involved transvaginal ultrasonography. In transcutaneous examinations, all hospitals were using alcohol and paper or cloth for decontamination at a minimum. Transesophageal examinations were carried out without barrier protection, and decontamination was performed with an alkylating substance. The hygiene practices appear to be appropriate at most hospitals, but there is a prevalence of transducer cover materials of unacceptable permeability, as well as use of gloves on transducers despite insufficient evidence of safety. © 2015 Wiley Periodicals, Inc.
Imaging the Endometrium: A Pictorial Essay.
Sadro, Claudia T
2016-08-01
Female gynaecologic conditions arising from the endometrium are common and depend on a woman's age, her menstrual history, and the use of medications such as hormone replacement and tamoxifen. Both benign and malignant conditions affect the endometrium. Benign conditions must be distinguished from malignant and premalignant conditions. The most commonly used imaging modality for evaluating the endometrium is pelvic ultrasound with transabdominal and transvaginal techniques. Additional imaging methods include hysterosonography and magnetic resonance imaging. This pictorial essay will review the normal and abnormal appearance of the endometrium and diagnostic algorithms to evaluate abnormal vaginal bleeding and abnormal endometrial thickness. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Hu, Maowen; Poder, Liina; Filly, Roy A
2014-09-01
New early first-trimester diagnostic criteria for nonviable pregnancy recommended by the Society of Radiologists in Ultrasound via a multispecialty consensus panel extended the diagnostic size criteria of crown-rump length from 5 to 7 mm for embryos without a heartbeat and mean sac diameter from 16 to 25 mm for "empty" sacs. Our study assessed the potential impact of the new criteria on the number of additional follow-up sonograms these changes would engender. A retrospective study of all first-trimester sonograms in women with first trimester bleeding from 1999 to 2008 was conducted. Everyone included in the study had a visible gestational sac in the uterus. There were no pregnancies of unknown location or ectopic pregnancies included in this study cohort. Pregnancy of unknown location was used to describe cases in which there were no signs of pregnancy inside or outside the uterus on transvaginal sonography despite a positive pregnancy test result. A total of 1013 patients met the inclusion criteria. Seven hundred fifty-two patients (74%) had identifiable embryos, and 261 (26%) did not. Of those with an identifiable embryo, 286 (38%) had no detectable embryonic cardiac activity. The breakdown of crown-rump lengths in this group was as follows: 100 measuring less than 5 mm, 36 measuring 5 to 7 mm, and 150 measuring 7 mm or greater. The breakdown of mean sac diameters in those without a visible embryo was as follows: 120 measuring less than 16 mm, 90 measuring 16 to 25 mm, and 51 measuring 25 mm or greater. When diagnosing a failed pregnancy, there can be no room for error. Only 126 of 1013 early pregnancies threatening to abort (12%) fell into the more conservative zones defined by the new compared to the former size criteria (crown-rump length, 5-7 mm; mean sac diameter, 16-25 mm). Therefore, the potential impact of the new guidelines on follow-up sonograms does not appear inordinate. © 2014 by the American Institute of Ultrasound in Medicine.
Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial
Tolsgaard, M G; Ringsted, C; Dreisler, E; Nørgaard, L N; Petersen, J H; Madsen, M E; Freiesleben, N L C; Sørensen, J L; Tabor, A
2015-01-01
Objective To study the effect of initial simulation-based transvaginal sonography (TVS) training compared with clinical training only, on the clinical performance of residents in obstetrics and gynecology (Ob-Gyn), assessed 2 months into their residency. Methods In a randomized study, new Ob-Gyn residents (n = 33) with no prior ultrasound experience were recruited from three teaching hospitals. Participants were allocated to either simulation-based training followed by clinical training (intervention group; n = 18) or clinical training only (control group; n = 15). The simulation-based training was performed using a virtual-reality TVS simulator until an expert performance level was attained, and was followed by training on a pelvic mannequin. After 2 months of clinical training, one TVS examination was recorded for assessment of each resident's clinical performance (n = 26). Two ultrasound experts blinded to group allocation rated the scans using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. Results During the 2 months of clinical training, participants in the intervention and control groups completed an average ± SD of 58 ± 41 and 63 ± 47 scans, respectively (P = 0.67). In the subsequent clinical performance test, the intervention group achieved higher OSAUS scores than did the control group (mean score, 59.1% vs 37.6%, respectively; P < 0.001). A greater proportion of the intervention group passed a pre-established pass/fail level than did controls (85.7% vs 8.3%, respectively; P < 0.001). Conclusion Simulation-based ultrasound training leads to substantial improvement in clinical performance that is sustained after 2 months of clinical training. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. PMID:25580809
Abel, M; Ahmed, H; Leen, E; Park, E; Chen, M; Wasan, H; Price, P; Monzon, L; Gedroyc, W; Abel, P
2015-01-01
High-intensity focused ultrasound (HIFU) is an ablative treatment undergoing assessment for the treatment of benign and malignant disease. We describe the first reported intracavitary HIFU ablation for recurrent, unresectable and symptomatic cervical cancer. A 38 year old woman receiving palliative chemotherapy for metastatic cervical adenocarcinoma was offered ablative treatment from an intracavitary trans-rectal HIFU device (Sonablate® 500). Pre-treatment symptoms included vaginal bleeding and discharge that were sufficient to impede her quality of life. No peri-procedural adverse events occurred. Symptoms resolved completely immediately post-procedure, reappeared at 7 days, increasing to pre-procedural levels by day 30. This first time experience of intracavitary cervical HIFU suggests that it is feasible for palliation of advanced cervical cancer, with no early evidence of unexpected toxicity. Ethical approval had also been granted for the use of per-vaginal access if appropriate. This route, alone or in combination with the rectal route, may provide increased accessibility in future patients with a redesigned device more suited to trans-vaginal ablations. Intracavitary HIFU is a potentially safe procedure for the treatment of cervical cancer and able to provide symptomatic improvement in the palliative setting.
Su, Jen-Min; Huang, Yu-Fang; Chen, Helen H W; Cheng, Ya-Min; Chou, Cheng-Yang
2006-05-01
To date, this is the first report to monitor changes of intratumor vascularization and the response to radiation and Cyberknife therapy in a patient with recurrent primary papillary serous carcinoma of the peritoneum by three dimensional (3D) power Doppler ultrasonography (PDUS). Transvaginal 3D PDUS detected a recurrent presacral tumor with abundant intratumor vascularity. Serial examinations of the tumor volume and serum CA-125 level were studied before, during, and 6 mo after therapy. Meanwhile, the intratumor blood flow was measured and expressed as vascularity indices. All of the tumor volume, intratumor vascularity indices and serum CA-125 level decreased progressively following therapy. A remaining lesion with nearly absent intratumor power Doppler signals suggested a scarring lesion posttreatment. Indeed, CT-guided tissue biopsy confirmed fibrotic change. 3D PDUS is useful to monitor the response to treatments and to differentiate residual tumors from lesions of scarring change posttreatment. It provides more accurate posttreatment information than pelvic computed tomography.
Wang, Chin-Jung; Yuen, Leung-To; Yen, Chih-Feng; Lee, Chyi-Long; Soong, Yung-Kuei
2004-12-01
An ectopic pregnancy developing in a previous Cesarean section scar is a rare event, and there is still a lack of information concerning the adequacy of management strategies. So far, no modality can guarantee the integrity of the uterus. We report the case of a 29-year-old woman with three Cesarean deliveries who was transferred to our hospital with a diagnosis of cervical pregnancy. Transvaginal three-dimensional power Doppler ultrasound revealed a well-encapsulated bulging mass displacing anteriorly over the lower anterior uterine wall sounding with an irregular course and branching vessels. The diagnosis of pregnancy in a previous Cesarean scar was made. Laparoscopic ligation of bilateral uterine arteries followed by excision of the ectopic pregnant mass was undertaken, and the patient's uterus was successfully preserved. Conservative management with the laparoscopic approach may be a safe and effective alternative to hysterectomy in patients with a pregnacy in a previous Cesarean scar.
Is Sonographic Assessment of the Cervix Necessary and Helpful?
Larma, Joel D.; Iams, Jay D.
2012-01-01
Transvaginal sonography of the cervix has emerged as a useful window onto preterm parturition. Cervical sonography allows measurements of cervical length which can aid clinicians in identifying women at risk for preterm birth. The use of transvaginal assessments of cervical length can assist in the triage of patients with possible preterm labor. Recent studies also support the use of cervical length measurements as a means of determining appropriate candidates for cerclage placement and progesterone supplementation to reduce the risk of premature birth, further highlighting the importance of this modality in modern obstetric management. PMID:22343248
Kang, Xiaomin; Wang, Tongfei; He, Liyin; Xu, Haijing; Liu, Zhilan; Zhao, Aimin
2016-12-01
The purpose of this study was to evaluate differences in uterine artery blood flow parameters and pregnancy outcomes, if any. An investigation was conducted to determine the effects of low-dose aspirin on uterine artery blood flow indices in patients with recurrent pregnancy loss. This observational study included 353 Chinese women with a history of recurrent pregnancy loss and 85 women without a history of recurrent pregnancy loss (control group) from Ren Ji Hospital. All patients were scanned transvaginally with transvaginal Doppler sonography 6 to 8 days after ovulation to measure the pulsatility index (PI), resistive index (RI), and systolic-to-diastolic ratio (S/D) of the left and right main uterine arteries. Low-dose aspirin at a dose of 50 mg/d was administered orally in patients with recurrent pregnancy loss for 2 months, and the blood flow indices were measured subsequently. The Student t test was used for analysis of the results, P < .05 was considered significant. The mean PI and S/D of the uterine arteries in the recurrent pregnancy loss group were significantly higher than in the control group. Although not statistically significant, the RI was higher in the recurrent pregnancy loss group than the control group. Moreover, the PI and S/D increased as the number of pregnancy losses increased. Significant enhancements of the PI and S/D were observed in patients with 4 or more consecutive abortions. After low-dose aspirin supplementation, patients with recurrent pregnancy loss showed a highly significant reduction in the PI and S/D. Uterine blood flow decreased during the luteal phase in patients with recurrent pregnancy loss. Low-dose aspirin induced a reversible increase in uterine blood flow and may be of therapeutic value. © 2016 by the American Institute of Ultrasound in Medicine.
Developing a knowledge base to support the annotation of ultrasound images of ectopic pregnancy.
Dhombres, Ferdinand; Maurice, Paul; Friszer, Stéphanie; Guilbaud, Lucie; Lelong, Nathalie; Khoshnood, Babak; Charlet, Jean; Perrot, Nicolas; Jauniaux, Eric; Jurkovic, Davor; Jouannic, Jean-Marie
2017-01-31
Ectopic pregnancy is a frequent early complication of pregnancy associated with significant rates of morbidly and mortality. The positive diagnosis of this condition is established through transvaginal ultrasound scanning. The timing of diagnosis depends on the operator expertise in identifying the signs of ectopic pregnancy, which varies dramatically among medical staff with heterogeneous training. Developing decision support systems in this context is expected to improve the identification of these signs and subsequently improve the quality of care. In this article, we present a new knowledge base for ectopic pregnancy, and we demonstrate its use on the annotation of clinical images. The knowledge base is supported by an application ontology, which provides the taxonomy, the vocabulary and definitions for 24 types and 81 signs of ectopic pregnancy, 484 anatomical structures and 32 technical elements for image acquisition. The knowledge base provides a sign-centric model of the domain, with the relations of signs to ectopic pregnancy types, anatomical structures and the technical elements. The evaluation of the ontology and knowledge base demonstrated a positive feedback from a panel of 17 medical users. Leveraging these semantic resources, we developed an application for the annotation of ultrasound images. Using this application, 6 operators achieved a precision of 0.83 for the identification of signs in 208 ultrasound images corresponding to 35 clinical cases of ectopic pregnancy. We developed a new ectopic pregnancy knowledge base for the annotation of ultrasound images. The use of this knowledge base for the annotation of ultrasound images of ectopic pregnancy showed promising results from the perspective of clinical decision support system development. Other gynecological disorders and fetal anomalies may benefit from our approach.
Enterobius vermicularis infection of the ovary.
Powell, George; Sarmah, Piyush; Sethi, Bhawana; Ganesan, Raji
2013-10-31
Enterobius vermicularis is an intestinal parasite, which may occasionally involve extraintestinal sites including the female genital tract. We report a rare case of ovarian involvement, which presented with chronic right iliac fossa pain in a 31-year-old woman. A transvaginal ultrasound scan was suggestive of a right adnexal dermoid cyst; however, histological examination of the subsequent salpingo-oophorectomy specimen showed an abscess containing viable E. vermicularis ova. E. vermicularis is the most prevalent human nematode worldwide. Its ova are ingested, larvae hatch and mature female worms journey to the perianal region where they lay eggs. Female worms may also migrate from the anus along the female genital tract. Although of low pathogenicity, complications such as infertility or peritonitis may arise.
Multicentre external validation of IOTA prediction models and RMI by operators with varied training
Sayasneh, A; Wynants, L; Preisler, J; Kaijser, J; Johnson, S; Stalder, C; Husicka, R; Abdallah, Y; Raslan, F; Drought, A; Smith, A A; Ghaem-Maghami, S; Epstein, E; Van Calster, B; Timmerman, D; Bourne, T
2013-01-01
Background: Correct characterisation of ovarian tumours is critical to optimise patient care. The purpose of this study is to evaluate the diagnostic performance of the International Ovarian Tumour Analysis (IOTA) logistic regression model (LR2), ultrasound Simple Rules (SR), the Risk of Malignancy Index (RMI) and subjective assessment (SA) for preoperative characterisation of adnexal masses, when ultrasonography is performed by examiners with different background training and experience. Methods: A 2-year prospective multicentre cross-sectional study. Thirty-five level II ultrasound examiners contributed in three UK hospitals. Transvaginal ultrasonography was performed using a standardised approach. The final outcome was the surgical findings and histological diagnosis. To characterise the adnexal masses, the six-variable prediction model (LR2) with a cutoff of 0.1, the RMI with cutoff of 200, ten SR (five rules for malignancy and five rules for benignity) and SA were applied. The area under the curves (AUCs) for performance of LR2 and RMI were calculated. Diagnostic performance measures for all models assessed were sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), and the diagnostic odds ratio (DOR). Results: Nine-hundred and sixty-two women with adnexal masses underwent transvaginal ultrasonography, whereas 255 had surgery. Prevalence of malignancy was 29% (49 primary invasive epithelial ovarian cancers, 18 borderline ovarian tumours, and 7 metastatic tumours). The AUCs for LR2 and RMI for all masses were 0.94 (95% confidence interval (CI): 0.89–0.97) and 0.90 (95% CI: 0.83–0.94), respectively. In premenopausal women, LR2−RMI difference was 0.09 (95% CI: 0.03–0.15) compared with −0.02 (95% CI: −0.08 to 0.04) in postmenopausal women. For all masses, the DORs for LR2, RMI, SR+SA (using SA when SR inapplicable), SR+MA (assuming malignancy when SR inapplicable), and SA were 62 (95% CI: 27–142), 43 (95% CI: 19–97), 109 (95% CI: 44–274), 66 (95% CI: 27–158), and 70 (95% CI: 30–163), respectively. Conclusion: Overall, the test performance of IOTA prediction models and rules as well as the RMI was maintained in examiners with varying levels of training and experience. PMID:23674083
Ovarian function after uterine artery embolization and hysterectomy.
Healey, Sarah; Buzaglo, Karen; Seti, Laurent; Valenti, David; Tulandi, Togas
2004-08-01
To evaluate the effect of uterine artery embolization (UAE) and hysterectomy on ovarian function. Prospective case control study (Canadian Task Force classification II-2). University teaching hospital. Eighty-four healthy premenopausal women with symptomatic uterine myoma(s) undergoing UAE or hysterectomy. Patients had blood drawn to measure follicle-stimulating hormone (FSH), luteinizing hormone (LH), and estradiol (E2) levels and underwent transvaginal ultrasound to measure volume of the myoma(s) and uterus on cycle day 3 before the procedures. These measurements were repeated 3 and 6 months after treatment. The main outcome was the differences in serum FSH, LH, E2, and ultrasound findings before and after UAE or hysterectomy. Of the 68 patients who underwent UAE and 16 who underwent hysterectomy, 48 and 13 respectively, completed 6-month follow-up. The mean age of the patients in the UAE group was 44.9 +/- 3.8 years and 43.7 +/- 5.6 years in the hysterectomy group. There was no significant difference in serum FSH before (8.9 +/- 0.7 IU/L) and 6 months after UAE (9.9 +/- 1.0 lU/L), and between the baseline (10.4 +/- 1.8 lU/L) and 6 months posthysterectomy (7.8 +/- 1.8 lU/L). The uterine volume 6 months after UAE (361 +/- 50 mL) was significantly smaller than before UAE(538 +/- 38mL; p =.005, 95% CI 44-241). Compared with baseline (154 +/- 20 mL), the dominant myoma volume was smaller at 6 months after UAE (97 +/- 16 mL; p <.05, 95% CI 1.57-62). Uterine artery embolization is associated with a significant reduction in myoma and uterine volume. Ovarian function at 6 months, as indicated by day 3 FSH levels, is not affected by UAE or hysterectomy.
Accuracy of ultrasound in antenatal diagnosis of placental attachment disorders.
Pilloni, E; Alemanno, M G; Gaglioti, P; Sciarrone, A; Garofalo, A; Biolcati, M; Botta, G; Viora, E; Todros, T
2016-03-01
To evaluate the accuracy of ultrasound in the diagnosis of placenta accreta and its variants, and to assess the impact of prenatal diagnosis in our population. A total of 314 women with placenta previa were enrolled prospectively and underwent transabdominal and transvaginal ultrasound examinations. An ultrasound diagnosis (grayscale and color/power Doppler) of placental attachment disorder (PAD) was based on the detection of at least two of the following ('two-criteria system'): loss/irregularity of the retroplacental clear zone, thinning/interruption of the uterine serosa-bladder wall interface, turbulent placental lacunae with high velocity flow, myometrial thickness < 1 mm, increased vascularity of the uterine serosa-bladder wall interface, loss of vascular arch parallel to the basal plate and/or irregular intraplacental vascularization. Definitive diagnosis was made at delivery by Cesarean section. Maternal outcome in cases diagnosed antenatally was compared with that in cases diagnosed at delivery. There were 37/314 cases of PAD (29 anterior and eight posterior). The two-criteria system identified 30 cases of placenta accreta, providing a sensitivity of 81.1% and specificity of 98.9%. When anterior and posterior placentae were considered separately, the detection rates of PAD were 89.7 and 50.0%, respectIvely. Maternal outcome was better in women with prenatal diagnosis of PAD, as seen by less blood loss and shorter hospitalization. Our data confirmed that grayscale and color Doppler ultrasound have good performance in the diagnosis of PAD and that prenatal diagnosis improves maternal outcome. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
New biomarkers for diagnosis and management of polycystic ovary syndrome.
Karakas, Sidika E
2017-08-01
Polycystic ovary syndrome (PCOS) is the most common endocrine disorder affecting young women. Even though the definition of PCOS has changed over the years, all diagnostic criteria include two or more of the following: oligomenorrhea/oligoovulation/anovulation, androgen excess and polycystic ovaries (PCO). Traditional method of assessing the ovarian morphology has been transvaginal pelvic ultrasound. Recent studies support that serum anti-Mullerian hormone (AMH) levels correlate with the number of ovarian follicles and cysts. Hence, measurement of AMH is adequate to make the diagnosis. Traditionally, hyperandrogenemia has been assessed by measuring total-testosterone. The literature stresses the importance of sex hormone binding globulin (SHBG) measurements and bioavailable-testosterone and free-testosterone calculations, because insulin resistance decreases SHBG, lowers total-testosterone, and leads to under-estimation of bioavailable- and free-testosterone. Since 50-60% of PCOS patients have metabolic syndrome, assessment of metabolic risk is also necessary. It is important to diagnose insulin resistance before development of glucose intolerance and diabetes. This requires measurements of not only plasma glucose but also insulin concentrations. Determination of HgBA1 can be informative as well. This review aims to present an accurate and cost-effective approach to diagnosis and management of PCOS. Copyright © 2017 Elsevier B.V. All rights reserved.
Understanding Patient Preference in Female Pelvic Imaging: Transvaginal Ultrasound and MRI.
Sakala, Michelle D; Carlos, Ruth C; Mendiratta-Lala, Mishal; Quint, Elisabeth H; Maturen, Katherine E
2018-04-01
Women with pelvic pain or abnormal uterine bleeding may undergo diagnostic imaging. This study evaluates patient experience in transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI) and explores correlations between preference and symptom severity. Institutional review board approval was obtained for this Health Insurance Portability and Accountability Act-compliant prospective study. Fifty premenopausal women with pelvic symptoms evaluated by recent TVUS and MRI and without history of gynecologic cancer or hysterectomy were included. A phone questionnaire used validated survey instruments including Uterine Fibroid Symptoms Quality of Life index, Testing Morbidities Index, and Wait Trade Off for TVUS and MRI examinations. Using Wait Trade Off, patients preferred TVUS over MRI (3.58 vs 2.80 weeks, 95% confidence interval [CI] -1.63, 0.12; P = .08). Summary test utility of Testing Morbidities Index for MRI was worse than for TVUS (81.64 vs 87.42, 95%CI 0.41, 11.15; P = .03). Patients reported greater embarrassment during TVUS than during MRI (P <.0001), but greater fear and anxiety both before (P <.0001) and during (P <.001) MRI, and greater mental (P = .02) and physical (P = .02) problems after MRI versus TVUS. Subscale correlations showed physically inactive women rated TVUS more negatively (R = -0.32, P = .03), whereas women with more severe symptoms of loss of control of health (R = -0.28, P = .04) and sexual dysfunction (R = -0.30, P = .03) rated MRI more negatively. Women with pelvic symptoms had a slight but significant preference for TVUS over MRI. Identifying specific distressing aspects of each test and patient factors contributing to negative perceptions can direct improvement in both test environment and patient preparation. Improved patient experience may increase imaging value. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Lee, Jung-Min; Levy, Doron
2016-01-01
High-grade serous ovarian cancer (HGSOC) represents the majority of ovarian cancers and accounts for the largest proportion of deaths from the disease. A timely detection of low volume HGSOC should be the goal of any screening studies. However, numerous transvaginal ultrasound (TVU) detection-based population studies aimed at detecting low-volume disease have not yielded reduced mortality rates. A quantitative invalidation of TVU as an effective HGSOC screening strategy is a necessary next step. Herein, we propose a mathematical model for a quantitative explanation on the reported failure of TVU-based screening to improve HGSOC low-volume detectability and overall survival.We develop a novel in silico mathematical assessment of the efficacy of a unimodal TVU monitoring regimen as a strategy aimed at detecting low-volume HGSOC in cancer-positive cases, defined as cases for which the inception of the first malignant cell has already occurred. Our findings show that the median window of opportunity interval length for TVU monitoring and HGSOC detection is approximately 1.76 years. This does not translate into reduced mortality levels or improved detection accuracy in an in silico cohort across multiple TVU monitoring frequencies or detection sensitivities. We demonstrate that even a semiannual, unimodal TVU monitoring protocol is expected to miss detectable HGSOC. Lastly, we find that circa 50% of the simulated HGSOC growth curves never reach the baseline detectability threshold, and that on average, 5–7 infrequent, rate-limiting stochastic changes in the growth parameters are associated with reaching HGSOC detectability and mortality thresholds respectively. Focusing on a malignancy poorly studied in the mathematical oncology community, our model captures the dynamic, temporal evolution of HGSOC progression. Our mathematical model is consistent with recent case reports and prospective TVU screening population studies, and provides support to the empirical recommendation against frequent HGSOC screening. PMID:27257824
Pineda, L; Alcázar, J L; Caparrós, M; Mínguez, J A; Idoate, M A; Quiceno, H; Solórzano, J L; Jurado, M
2016-03-01
To compare diagnostic performance of preoperative transvaginal ultrasound (TVS) and intraoperative macroscopic examination for determining myometrial infiltration in women with low-risk endometrial cancer, and to estimate the agreement between the two methods. This was a single-center observational study comprising women with preoperative diagnosis of well- or moderately differentiated endometrioid carcinoma of the endometrium. All women underwent preoperative TVS by a single examiner. According to the examiner's subjective impression, myometrial infiltration was stated as ≥ 50% or < 50%. Surgical staging was performed in all cases. Intraoperative macroscopic examination of the removed uterus was performed by pathologists who were unaware of the ultrasound findings, and myometrial infiltration was stated as ≥ 50% or < 50%. Definitive histological diagnosis of myometrial infiltration was made by frozen section analysis and was used as the gold standard. Sensitivity and specificity with 95% CIs were calculated for TVS and intraoperative macroscopic inspection and compared using McNemar's test. Agreement between TVS and intraoperative macroscopic inspection was estimated using Cohen's kappa index (κ) and percentage of agreement. Of 209 eligible women, 152 were ultimately included. Mean (± SD) age was 60.9 ± 10.2 years, with a range of 32-91 years. Definitive histological diagnosis revealed that myometrial infiltration was < 50% in 114 women and ≥ 50% in 38 women. Sensitivity and specificity of TVS for detecting deep myometrial infiltration were 81.6% and 89.5%, respectively, whereas the respective values for intraoperative macroscopic examination were 78.9% and 90.4% (McNemar's test, P > 0.05 when comparing TVS and intraoperative macroscopic examination). Agreement between methods was moderate with κ = 0.54 (95% CI, 0.39-0.69) and percentage of agreement of 82%. Although the agreement between preoperative TVS and intraoperative macroscopic examination for detecting deep myometrial infiltration was only moderate, both methods had similar accuracy when compared with frozen section histology. Preoperative TVS might reasonably be proposed as a method for assessing myometrial infiltration as an alternative to intraoperative macroscopic examination, especially when performed by an experienced examiner and image quality is not poor. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Transvaginal organ extraction: potential for broad clinical application.
Jacobsen, Garth R; Barajas-Gamboa, Juan S; Coker, Alisa M; Cheverie, Joslin; Macias, C Aitor; Sandler, Bryan J; Talamini, Mark A; Horgan, Santiago
2014-02-01
Natural orifice transluminal endoscopic surgery procedures have evolved over the past few years. A transvaginal approach is a promising alternative for intraperitoneal procedures. Our objective was to evaluate the safety and feasibility of transvaginal organ extraction. This institutional review board-approved protocol involved retrospective review of an ongoing prospective study. Female subjects who presented to our hospital for elective cholecystectomy, appendectomy, or sleeve gastrectomy were offered participation in the study. Eligible patients met the following criteria: age between 18 and 75, diagnosis of gallbladder disease, acute appendicitis, or morbid obesity who desired surgical treatment. A hybrid transvaginal natural orifice approach was used in this series. Thirty-four women underwent transvaginal organ extraction between September 2007 and January 2012. The mean age was 40 ± 12.1 years (range 23-63 years). The mean body mass index was 27 ± 6.4 kg/m(2) (range 16-43 kg/m(2)). All patients had an American Society of Anesthesiologists classification of two or below. The mean operative time for cholecystectomy, appendectomy, and sleeve gastrectomy was 90, 71, and 135 min, respectively. There were no conversions to open operation and no intraoperative complications. The mean hospital stay was 2 days for all cases. Patients were followed for a mean of 24 months (range 1-61 months). There were two pregnancies and two successful vaginal deliveries. Six patients (18 %) had minor complaints of spotting or heavy menses in the immediate postoperative period that resolved with conservative measures. There were no abdominal wall complications. There were no long-term complications and no mortalities. This initial experience suggests that this surgical approach is safe, does not increase length of stay, and has no long-term vaginal complications. Given this attractive profile, a transvaginal approach may prove to be a superior mode of organ extraction, although randomized studies and long-term follow-up are needed.
Senft, Jonas D; Warschkow, Rene; Diener, Markus K; Tarantino, Ignazio; Steinemann, Daniel C; Lamm, Sebastian; Simon, Thomas; Zerz, Andreas; Müller-Stich, Beat P; Linke, Georg R
2014-11-20
Natural orifice transluminal endoscopic surgery (NOTES) is the consequence of further development of minimally invasive surgery to reduce abdominal incisions and surgical trauma. The potential benefits are expected to be less postoperative pain, faster convalescence, and reduced risk for incisional hernias and wound infections compared to conventional methods. Recent clinical studies have demonstrated the feasibility and safety of transvaginal NOTES, and transvaginal access is currently the most frequent clinically applied route for NOTES procedures. However, despite increasing clinical application, no firm clinical evidence is available for objective assessment of the potential benefits and risks of transvaginal NOTES compared to the current surgical standard. The TRANSVERSAL trial is designed as a randomized controlled trial to compare transvaginal hybrid NOTES and laparoscopic-assisted sigmoid resection. Female patients referred to elective sigmoid resection due to complicated or reoccurring diverticulitis of the sigmoid colon are considered eligible. The primary endpoint will be pain intensity during mobilization 24 hours postoperatively as measured by the blinded patient and blinded assessor on a visual analogue scale (VAS). Secondary outcomes include daily pain intensity and analgesic use, patient mobility, intraoperative complications, morbidity, length of stay, quality of life, and sexual function. Follow-up visits are scheduled 3, 12, and 36 months after surgery. A total sample size of 58 patients was determined for the analysis of the primary endpoint. The confirmatory analysis will be performed based on the intention-to-treat (ITT) principle. The TRANSVERSAL trial is the first study to compare transvaginal hybrid NOTES and conventionally assisted laparoscopic surgery for colonic resection in a randomized controlled setting. The results of the TRANSVERSAL trial will allow objective assessment of the potential benefits and risks of NOTES compared to the current surgical standard for sigmoid resection. The trial protocol was registered in the German Clinical Trials Register ( DRKS00005995) on March 27, 2014.
Nakajima, Kiyokazu; Takahashi, Tsuyoshi; Souma, Yoshihito; Shinzaki, Shinichiro; Yamada, Takuya; Yoshio, Toshiyuki; Nishida, Toshirou
2008-12-01
Transvaginal natural orifice translumenal endoscopic surgery (NOTES) gastrectomy is technically challenging, because wide perigastric dissection under appropriate tissue triangulation is unfeasible with current endoscopic instruments alone. The aim of this study was to investigate the feasibility of transvaginal NOTES gastrectomy with the use of an extra endoscope as a retracting device of the stomach. This acute in vivo feasibility study was performed under the approval of the Institutional Animal Care and Use Committee (IACUC). Four female 40-kg pigs received general anesthesia and underwent transvaginal endoscopic partial gastrectomy. Under laparoscopic guidance, the uterus was fixed anteriorly and transvaginal access was established in a standard fashion. The perigastric ligaments were dissected with needle knife/insulation-tipped electrosurgical knife (IT) via transvaginally placed double-channel endoscope. This step was assisted with the second, CO(2)-insufflating endoscope advanced in the stomach (i.e., so-called endoscopic gastric control). A linear stapling device with a flexible shaft was then passed transvaginally, and the anterior gastric wall was partially resected. The specimen was isolated and retrieved through the vagina. Concluding endoscopy was carried out to confirm the absence of mucosal damage due to endoscopic gastric control. This was further confirmed at necropsy immediately after sacrifice. All animals underwent successful transvaginal NOTES gastrectomy. Endoscopic gastric control greatly facilitated perigastric dissection by providing appropriate tissue countertraction on the ligaments. Use of transabdominal (laparoscopic) graspers was thus minimized. There were no intraoperative complications directly related to use of the primary (transvaginal) endoscope or the additional (gastric) endoscope. Distention of downstream bowel after gastric insufflation was minimal with CO(2). No major injuries were noted on gastric mucosa at postmortem investigations. Transvaginal NOTES partial gastrectomy is feasible in porcine models. Use of an extra endoscope to retract the stomach is effective to minimize transabdominal assistance. Further studies on human subjects are necessary to establish this as a safe and attractive ancillary technique in NOTES.
Negative βhCG and Molar Pregnancy: The Hook Effect.
Lobo Antunes, Isabel; Curado, Joana; Quintas, Ana; Pereira, Alcides
2017-09-29
Molar pregnancy, included in gestational trophoblastic disease, is a benign pathology with ability to metastasize, usually occurring with excessively high βhCG levels. Clinical scenario is usually a woman in extremes of reproductive age presenting with amenorrhoea, pain and vaginal blood loss; signs derived from high βhCG levels may be present (hyperthyroidism, hyperemesis). Diagnosis is based on a positive pregnancy test - usually a qualitative urinary test. The limitation of this test results from its inability to become positive in presence of markedly high levels of βhCG, saturating the antigens used - known as the 'hook effect'. With the widespread use of gynaecological ultrasound cases of molar pregnancy have been diagnosed in timely fashion. We describe a case referred as a degenerating fibroid, with a negative urinary pregnancy test. Transvaginal ultrasound was highly suggestive of molar pregnancy, which was confirmed with a quantitative βhCG test, allowing for timely treatment. The importance of a high index of suspicion for this pathology is tremendous to avoid the devastating consequences of a delayed diagnosis.
The accuracy of transvaginal sonography to detect endometriosis cyst
NASA Astrophysics Data System (ADS)
Diantika, M.; Gunardi, E. R.
2017-08-01
Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.
Enterobius vermicularis infection of the ovary
Powell, George; Sarmah, Piyush; Sethi, Bhawana; Ganesan, Raji
2013-01-01
Summary Enterobius vermicularis is an intestinal parasite, which may occasionally involve extraintestinal sites including the female genital tract. We report a rare case of ovarian involvement, which presented with chronic right iliac fossa pain in a 31-year-old woman. A transvaginal ultrasound scan was suggestive of a right adnexal dermoid cyst; however, histological examination of the subsequent salpingo-oophorectomy specimen showed an abscess containing viable E. vermicularis ova. E. vermicularis is the most prevalent human nematode worldwide. Its ova are ingested, larvae hatch and mature female worms journey to the perianal region where they lay eggs. Female worms may also migrate from the anus along the female genital tract. Although of low pathogenicity, complications such as infertility or peritonitis may arise. PMID:24177459
Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A
2007-01-01
Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.
Postmenopausal palpable ovary and ovarian cancer.
Gojnić, M; Branković, M; Maksimović, M; Parapid, B; Dugalić, V; Jeremić, K; Gutić, B
2011-01-01
Ultrasound (US) examination is a much more reliable method for evaluation of potential ovarian cancer risk than gynecologic palpation. The aim of our study was to analyze the US characteristics of patients with palpable ovaries in light of potential for malignancy. We analyzed 70 women ten years after menopause without increased CA 125 values. They underwent clinical and US exams (abdominal and transvaginal ultrasound), with special emphasis on US Doppler exam. Bimanuel gynecological examination showed palpable ovaries in 14 patients (palpable ovary group), and the remaining 56 patients were defined as the control group. US showed increased dimensions of palpable ovaries. Atypical follicular activity, deviation from verticalization, atypical ovaries and hyperechogenic punctations classified under germ cell cysts occurred statistically significantly more often in the palpable ovary group. Doppler flow showed pathological vascularization in five patients with palpable ovaries and the estrogen level was increased. After four to six months in these five patients we found a mild increase of estrogen levels and higher Doppler abnormality. Six months later, two patients had irregular bleeding and underwent surgical treatment. Every adnexal mass after menopausis demands special attention. Bimanuel gynecological exams should be used liberally. It is necessary to follow the dimensions of the ovary, describe the echostructure, as well as the edges of the ovary and other anatomical structures. Doppler flow measurement and estrogen levels are predictive and give more information. Controls should be in three to six month intervals in order to make a decision for surgical treatment.
Successful treatment of two viable tubal pregnancies by two-step local injection.
Jehng, C H; Ng, K Y; Jou, H J; Jenh, A L; Lien, Y R
1992-08-01
Two viable tubal pregnancies were diagnosed by transvaginal ultrasound with a serum beta-hCG level of up to 3,004 mIU/mL in Case 1 and 16,676 mIU/mL in Case 2. Under transvaginal sonographic guidance, a local injection of potassium chloride (0.5 mL = 1.0 mEq) into the embryo was performed for the purpose of embryocide. In Case 1, a follow-up of serum beta-hCG levels showed an initial plateau and subsequent regression to negative, 49 days after the local injection. However, a persistent increase in serum beta-hCG levels was noted in Case 2 for two samples at intervals of two days during follow-up, 27,800 and 36,500 mIU/mL, in spite of the fact that no fetal cardiac activity was visible. Six days later, laparoscopy was done and methotrexate, 50 mg in 6 mL of normal saline, was injected into the ampullar mass of the right fallopian tube in two divided dosages. The serum beta-hCG levels then gradually decreased and returned to negative 60 days after the methotrexate injection. For a viable ectopic pregnancy, this new modality of two-step local injection, first with potassium chloride and then with supplemental methotrexate, separately by two procedures, may offer an additional choice of conservative treatment.
Salivary progesterone and cervical length measurement as predictors of spontaneous preterm birth.
Maged, Ahmed M; Mohesen, Mohamed; Elhalwagy, Ahmed; Abdelhafiz, Ali
2015-07-01
To evaluate the efficacy of salivary progesterone, cervical length measurement in predicting preterm birth (PTB). Prospective observational study included 240 pregnant women with gestational age (GA) 26-34 weeks classified into two equal groups; group one are high risk for PTB (those with symptoms of uterine contractions or history of one or more spontaneous preterm delivery or second trimester abortion) and group 2 are controls. There was a highly significant difference between the two study groups regarding GA at delivery (31.3 ± 3.75 in high risk versus 38.5 ± 1.3 in control), cervical length measured by transvaginal ultrasound (24.7 ± 8.6 in high risk versus 40.1 ± 4.67 in control) and salivary progesterone level (728.9 ± 222.3 in high risk versus 1099.9 ± 189.4 in control; p < 0.001). There was a statistically significant difference between levels of salivary progesterone at different GA among the high risk group (p value 0.035) but not in low risk group (p value 0.492). CL measurement showed a sensitivity of 71.5% with 100% specificity, 100% PPV, 69.97% NPV and accuracy of 83%, while salivary progesterone showed a sensitivity of 84% with 90% specificity, 89.8% PPV, 85.9% NPV and accuracy of 92.2%. The measurement of both salivary progesterone and cervical length are good predictors for development of PTB.
The feasibility of transvaginal robotic surgery in the repair of pelvic organ prolapse.
Yaghnam, Ibrahim; Thomas, Dominique; Rosenblatt, Peter; Chughtai, Bilal
2017-08-01
Pelvic organ prolapse (POP), the descent of one or more pelvic organs, occurs in an estimated 40 to 60% of parous women. Conventional transvaginal surgery for POP has been plagued with high failure rates. The purpose was to determine the safety and feasibility of robotic transvaginal POP surgery. The da Vinci Surgical Robot, SI was used in the POP surgical procedures. There were two cadavers (aged 18 and 78 years of age; BMI 17.2 and 19.2 respectively). POP-Q scores before intervention were stage 1 for both cadavers. The visualization of anatomical landmarks and the placement of sutures at these locations were successful. Robotic transvaginal POP is a feasible option for POP surgery. Further studies are warranted to determine the role of robotic transvaginal POP repair.
Fulghesu, A M; Angioni, S; Frau, E; Belosi, C; Apa, R; Mioni, R; Xamin, N; Capobianco, G P; Dessole, S; Fruzzetti, F; Lazzarini, V; Minerba, L; Melis, G B; Lanzone, A
2007-09-01
The introduction of transvaginal approach in ultrasound (US) has enabled the accurate evaluation of the structure of the ovary and stroma. Stroma represents an acknowledged US marker for polycystic ovary syndrome (PCOS). The proportion revealed between the stroma and the ovary surface in the median section (S/A ratio) had been indicated as a reliable marker for hyperandrogenism. In order to verify the feasibility of this determination in routine use and to confirm the efficacy of S/A ratio in predicting hyperandrogenism in PCOS, a multicentric study was performed in association with five Italian research groups. A total of 418 subjects of fertile age presenting oligomenorrhoea or secondary amenorrhoea, enlarged ovaries measuring >10 cm(3) and/or >12 follicles measuring 2-9 mm in diameter took part in the study. Clinical, US and hormonal evaluations were performed in the early follicular phase or on random days in amenorrhoeic subjects. US assessment included ovarian volume, follicle number, ovarian and stroma area in median section. The hormonal study included a baseline plasma determination of LH, FSH, estradiol (E(2)), androstenedione (A), testosterone (T), dehydroepiandrosteronesulphate, 17-hydroxy-progesterone, sex hormone-binding globulin and prolactin. Correlations and receiver operator curves were used in statistical analysis of data. S/A was found to be the best significant predictor of elevated A and T levels. In order to ascertain significant cut-off values in relation to A and T levels Youden indexes were calculated and indicated 0.32 as the best cut-off for the S/A ratio. This work underlines the importance of stroma measure in improving US diagnosis of PCOS and suggest that this parameter may be used in routine clinical practice. In fact, multicentre study demonstrated the easy feasibility of such procedure without need of sophisticated machines or intensive training for operators.
Khazendar, S; Sayasneh, A; Al-Assam, H; Du, H; Kaijser, J; Ferrara, L; Timmerman, D; Jassim, S; Bourne, T
2015-01-01
Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered.
[Imaging of pelvic organ prolapse].
Lapray, Jean-François
2013-01-01
Colpocystodefecography (CCD) and dynamic MRI with defecography (MRId) allow an alternation between filling and emptying the hollow organs and the maximum abdominal strain offered by the defecation. When applied in imaging these two principles reveal the masked or underestimated prolapses at the time of the physical examination. A rigorous application of the technique guarantees almost equivalent results from the two examinations. The CCD provides voiding views and improved analysis of the anorectal pathology (intussusception, anismus) but involves radiation and a more invasive examination. MRId has the advantage of providing continuous visibility of the peritoneal compartment, and a multiplanar representation, enabling an examination of the morphology of the pelvic organs and of the supporting structures, with the disadvantage of still necessitating a supine examination, resulting sometimes in an incomplete or impossible evacuation. The normal and abnormal results (cystoptosis, vaginal vault prolapse, enterocele, anorectal intussuception, rectocele, descending perineum, urinary and fecal incontinence) and the respective advantages and limits of the various imaging methods are detailed. Dynamic perineal and introital ultrasound remains more limited in the appreciation of posterior colpoceles and especially in anorectal disorders, than CCD or MRId. Endoanal ultrasound is the first line morphological evaluation of the anal sphincter. Transvaginal and introital ultrasound can detect some complications of suburethral tapes and meshes. Morphological and dynamic imaging are essential complementary tools to the physical examination, especially when a precise anatomic assessment is required to understand the functional complaint or when a reintervention is needed.
Three-dimensional ultrasound for prenatal assessment of conjoined twins: additional advantages?
Wataganara, Tuangsit; Ruangvutilert, Pornpimol; Sunsaneevithayakul, Prasert; Russameecharoen, Kusol; Nawapun, Katika; Phithakwatchara, Nisarat
2017-08-28
Conjoined twins are a rare, but serious, complication of monozygotic twins. Early prenatal diagnosis of conjoined twins is increasingly made with transvaginal ultrasound and color Doppler studies. Most prenatally diagnosed conjoined twins are terminated due to the high perinatal mortality, but advancement in pediatric surgery has allowed for successful postnatal separation in a small number of cases, and some parents may consider this option over termination of pregnancy. It is important to get a detailed prenatal ultrasound for the site and extent of fusion for an accurate categorization. Three-dimensional ultrasound (3DUS) provides images that can facilitate counselling for the parents. Additional information that impacts on diagnosis, prognostication, and perinatal management of conjoined twins could be obtained from selective use of 3DUS, particularly those with atypical fetal union. Most of the proposed additional benefits of 3DUS are based on case reports. Magnetic resonance imaging (MRI) has been increasingly used for the purpose of identifying intricate organ sharing. Because of the rarity of this condition, and the heterogeneity of fetal fusion, added benefits of either 3DUS or MRI for prenatal diagnosis and perinatal management of conjoined twins have not been demonstrated by well-conducted clinical trials. This article aims to review clinical application of various 3DUS display modes in prenatal assessment of conjoined twins, focusing on their potential additional benefits, risks and misuses. 3DUS may help detecting additional findings that are not possible with 2DUS, but, it has not been scientifically shown to improve the survival rate of the twins or reduce maternal morbidity.
Cypher, Rebecca L
2012-01-01
Women who have delivered an infant between 16 and 36 weeks' gestation have an increased risk of preterm birth (PTB) in a subsequent pregnancy. The high incidence of recurrent PTB remains relatively unchanged despite intensive research efforts and advances in perinatal care. Attempts to decrease the incidence of recurrent PTB have not always been successful, with research efforts being focused on clinical, pharmacotherapy and biochemical, and ultrasound strategies. Fortunately, there is adequate evidence in the literature to justify clinical management guidelines that may impact the PTB rate: smoking cessation, treatment of asymptomatic bacteriuria, transvaginal ultrasonography of the cervix, administration of vaginal progesterone or 17α-hydroxyprogesterone caproate, cerclage, and fetal fibronectin. This article is intended to give brief highlights of these strategies and the current science that supports their conclusions.
Qualitative and quantitative analysis of women's perceptions of transvaginal surgery.
Bingener, Juliane; Sloan, Jeff A; Ghosh, Karthik; McConico, Andrea; Mariani, Andrea
2012-04-01
Prior surveys evaluating women's perceptions of transvaginal surgery both support and refute the acceptability of transvaginal access. Most surveys employed mainly quantitative analysis, limiting the insight into the women's perspective. In this mixed-methods study, we include qualitative and quantitative methodology to assess women's perceptions of transvaginal procedures. Women seen at the outpatient clinics of a tertiary-care center were asked to complete a survey. Demographics and preferences for appendectomy, cholecystectomy, and tubal ligation were elicited, along with open-ended questions about concerns or benefits of transvaginal access. Multivariate logistic regression models were constructed to examine the impact of age, education, parity, and prior transvaginal procedures on preferences. For the qualitative evaluation, content analysis by independent investigators identified themes, issues, and concerns raised in the comments. The completed survey tool was returned by 409 women (grouped mean age 53 years, mean number of 2 children, 82% ≥ some college education, and 56% with previous transvaginal procedure). The transvaginal approach was acceptable for tubal ligation to 59%, for appendectomy to 43%, and for cholecystectomy to 41% of the women. The most frequently mentioned factors that would make women prefer a vaginal approach were decreased invasiveness (14.4%), recovery time (13.9%), scarring (13.7%), pain (6%), and surgical entry location relative to organ removed (4.4%). The most frequently mentioned concerns about the vaginal approach were the possibility of complications/safety (14.7%), pain (9%), infection (5.6%), and recovery time (4.9%). A number of women voiced technical concerns about the vaginal approach. As in prior studies, scarring and pain were important issues to be considered, but recovery time and increased invasiveness were also in the "top five" list. The surveyed women appeared to actively participate in evaluating the technical components of the procedures.
Zhong, X L; Song, J; Xu, Y L; Lyu, X L; Zhong, X H; Wang, A P; Song, Y F
2017-09-25
Objective: To evaluate transperineal sonography for lower urinary tract symptoms after pelvic floor reconstruction. Methods: Eighty-three patients with severe pelvic organ prolapse received surgeries in Fuzhou General Hospital from September 2014 to September 2015, dividing into two groups: 27 patients were selected to receive transvaginal mesh (TVM) pelvic floor reconstruction surgery with tension-free vaginal tape-Abbrevo (TVT-Abbrevo) incontinence surgery, named TVM+TVT-Abbrevo group; 56 patients were selected to receive TVM pelvic floor reconstruction surgery only, named TVM group. The ultrasonic parameters at rest, on contraction and Valsalva condition respectively were observed and measured, including the bladder neck descent (BND), urethral rotation angle, retrovesical angle, levator urethra gap (LUG), the existence of bladder neck funneling, position of the tape, by using 2D and 3D transperineal ultrasound. Results: The two groups were compared with the ultrasonic parameters before and after operation: two groups of patients with postoperative BND [(2.3±0.5) versus (3.1±0.7) cm, (1.6±0.4) versus (3.6±0.4) cm] were significantly reduced, the difference was statistically significant ( P= 0.02, P< 0.01). The two groups of LUG before and after operation [(3.62±0.45) versus (3.26±0.92) cm, (2.96±0.47) versus (2.72±0.38) cm] both had significant difference by maximum Valsalva ( P< 0.01, P= 0.04). There was statistical significance difference of urethral rotation angle in TVM+TVT-Abbrevo group by maximum Valsalva ( P= 0.01). Observation of morphology: (1) 2 patients with difficulty in urination in TVM+TVT-Abbrevo group, ultrasound showed when the position of the bladder down the urethra discount; 4 patients with stress urinary incontinence (SUI), ultrasound showed slings off or release. (2) One patient with difficulty in urination in TVM group, but ultrasound showed lower urinary tract anatomy were normal; 5 patients with SUI, ultrasound showed the position of the bladder neck were significantly lower in 3 patients, showing high mobility, and the other 2 patients had a larger urethral diameter, showing a tendency of natural deletion. Conclusion: s Anatomy of lower urinary tract could be clearly showed by transperineal sonography. This could provide imaging support for the diagnosis of lower urinary tract symptoms after pelvic floor reconstruction.
Findley, Joseph; Seybold, Dara J; Broce, Mike; Yadav, Dolly; Calhoun, Byron C
2015-01-01
Currently ACOG recommends that a mid-term screening strategy may be considered to identify short cervix in low risk populations in an effort to prevent preterm birth. Vaginal progesterone is recommended for women with a cervical length ≤20 mm. Cerclage is recommended for women with prior spontaneous preterm birth who are already receiving progesterone supplementition and CL is <25 mm. This study examined risk factors for spontaneous preterm birth (SPB) <35 weeks among a general obstetrical population prior to these ACOG recommendations. However, cervical cerclage was a possible intervention. Study population included 1,074 patients from 1 Jan 2007-30 Jun 2008 receiving mid-trimester transvaginal ultrasounds during prenatal care at a tertiary medical center clinic. Receiver operator characteristic (ROC) curve cutoff optimal value was ≤34 mm, (n=224), corresponding to 8.9% SPB with shortened cervices compared to 1.4% in patients with normal cervices (>34 mm; n=850; p<0.001 (Area Under the Curve (AUC) 76.6, p<0.001). Cervical lengths <30 mm had 12 times the risk of SPB (p<0.001) while 30-34 mm had 5 times (p=0.005). Tobacco use (≥10 cigarettes per day), p=0.030, and low BMI, p=0.034, had additive effect. Shortened cervical length during routine screening independently predicted SPB while heavy smoking with shortened cervix during pregnancy doubled risk compared to shortened cervix alone.
Findley, Joseph; Seybold, Dara J.; Broce, Mike; Yadav, Dolly; Calhoun, Byron C.
2015-01-01
Currently ACOG recommends that a mid-term screening strategy may be considered to identify short cervix in low risk populations in an effort to prevent preterm birth. Vaginal progesterone is recommended for women with a cervical length ≤20 mm. Cerclage is recommended for women with prior spontaneous preterm birth who are already receiving progesterone supplementation and CL is <25 mm. This study examined risk factors for spontaneous preterm birth (SPB) <35 weeks among a general obstetrical population prior to these ACOG recommendations. However, cervical cerclage was a possible intervention. Study population included 1,074 patients from 1 Jan 2007-30 Jun 2008 receiving mid-trimester transvaginal ultrasounds during prenatal care at a tertiary medical center clinic. Receiver operator characteristic (ROC) curve cutoff optimal value was ≤34 mm, (n=224), corresponding to 8.9% SPB with shortened cervices compared to 1.4% in patients with normal cervices (>34 mm; n=850; p<0.001 (Area Under the Curve (AUC) 76.6, p<0.001). Cervical lengths <30 mm had 12 times the risk of SPB (p<0.001) while 30-34 mm had 5 times (p=0.005). Tobacco use (≥10 cigarettes per day), p=0.030, and low BMI, p=0.034, had additive effect. Shortened cervical length during routine screening independently predicted SPB while heavy smoking with shortened cervix during pregnancy doubled risk compared to shortened cervix alone. PMID:26050294
Diagnostic dilemma in ovarian pregnancy: a case series.
Begum, Jasmina; Pallavee, P; Samal, Sunita
2015-04-01
Ovarian pregnancy is a rare form of ectopic pregnancy but it is the most common type of nontubal ectopic pregnancy. Many times it is operated with a misdiagnosis of ruptured tubal ectopic pregnancy or hemorrhagic corpus luteum. The high resolution transvaginal ultrasonography is a valuable tool for diagnosis of ectopic pregnancy but ovarian pregnancy still remains a diagnostic problem and a continuous challenge to the gynecologist. The correct diagnosis is made at the time of surgery and confirmation is by histopathological report. Here we report three cases of primary ovarian ectopic pregnancies, consistent with the Spiegelberg's criteria. Out of this, two cases have corroboration of ovarian ectopic pregnancy with use of intrauterine contraceptive device and one case by chance without any preexisting risk factors, probably due to interference in the release of ovum from the follicle. In all the three cases, emergency laparotomy was done for ruptured tubal ectopic pregnancy and the diagnosis of ruptured primary ovarian pregnancy was made at the time of surgery, this was subsequently confirmed by histopathology report. In the era where wider usage of intrauterine devices, ovulatory drugs and assisted reproductive techniques are rife, there is a possibility of an increase in the incidence of this rare entity, so ovarian ectopic pregnancy should be kept in mind as a possibility. Thereby early diagnosis by high resolution transvaginal ultrasound and laparoscopy can decrease the risk of complications like rupture, secondary implantation, hemorrhagic shock and maternal mortality.
The natural history of fibroids.
Mavrelos, D; Ben-Nagi, J; Holland, T; Hoo, W; Naftalin, J; Jurkovic, D
2010-02-01
Fibroids are common, hormone-dependent, benign uterine tumors. They can cause significant morbidity and the symptoms depend largely on their size. The aim of this study was to describe the natural history of fibroids and identify factors that may influence their growth. This was a retrospective longitudinal study of premenopausal women who were diagnosed with uterine fibroids on ultrasound examination. All women underwent at least two transvaginal ultrasound scans, which were all performed by a single operator. Fibroids were measured in three perpendicular planes and the mean diameter was calculated. The size and position of every individual fibroid was assessed and recorded on a computerized database. The volume of each fibroid was calculated using the formula for a sphere. A total of 122 women were included in the study. Their median age at the initial examination was 40 (range, 27-45) years. Seventy-two (59.0%) were nulliparous and 74 (60.7%) had multiple fibroids. The median interval between the initial and final examination was 21.5 (range, 8-90) months. The median fibroid volume increased by 35.2% per year. Small fibroids (< 20 mm mean diameter) grew significantly faster than larger fibroids (P = 0.007). The median increase in size was significantly higher in cases of intramural fibroids (53.2 (interquartile range (IQR), 11.2-217)%) than in subserous fibroids (25.1 (IQR, 1.1-87.1)%) and submucous fibroids (22.8 (IQR, - 11.7 to 48.3)%) (P = 0.012). Multivariate analysis retained only fibroid size at presentation as an independent predictor of fibroid growth. The growth of fibroids in premenopausal women is influenced by the tumor's size at presentation.
[Management of endometriosis: CNGOF-HAS practice guidelines (short version)].
Collinet, P; Fritel, X; Revel-Delhom, C; Ballester, M; Bolze, P A; Borghese, B; Bornsztein, N; Boujenah, J; Bourdel, N; Brillac, T; Chabbert-Buffet, N; Chauffour, C; Clary, N; Cohen, J; Decanter, C; Denouël, A; Dubernard, G; Fauconnier, A; Fernandez, H; Gauthier, T; Golfier, F; Huchon, C; Legendre, G; Loriau, J; Mathieu-d'Argent, E; Merlot, B; Niro, J; Panel, P; Paparel, P; Philip, C A; Ploteau, S; Poncelet, C; Rabischong, B; Roman, H; Rubod, C; Santulli, P; Sauvan, M; Thomassin-Naggara, I; Torre, A; Wattier, J M; Yazbeck, C; Canis, M
2018-03-01
First-line investigations to diagnose endometriosis are clinical examination and pelvic ultrasound. Second-line investigations include pelvic examination performed by a referent clinician, transvaginal ultrasound performed by a referent echographist, and pelvic MRI. It is recommended to treat endometriosis when it is symptomatic. First-line hormonal treatments recommended for the management of painful endometriosis are combined with hormonal contraceptives or levonorgestrel 52mg IUD. There is no evidence to recommend systematic preoperative hormonal therapy for the unique purpose of preventing the risk of surgical complications or facilitating surgery. After endometriosis surgery, combined hormonal contraceptives or levonorgestrel SIU 52mg are recommended as first-line therapy in the absence of desire of pregnancy. In case of initial treatment failure, recurrence, or multiple organ involvement by endometriosis, medico-surgical and multidisciplinary discussion is recommended. The laparoscopic approach is recommended for the surgical treatment of endometriosis. HRT may be offered in postmenopausal women operated for endometriosis. In case of infertility related to endometriosis, it is not recommended to prescribe anti-gonadotropic hormone therapy to increase the rate of spontaneous pregnancy, including postoperatively. The possibilities of fertility preservation should be discussed with the patient in case of surgery for ovarian endometrioma. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Api, Murat; Api, Olus
2010-03-01
To report the successful treatment of an advanced interstitial ectopic pregnancy via laparoscopic cornuotomy following treatment failure with methotrexate (MTX). A 28-year-old, gravida 3, para 0 woman with a history of successfully treated tubal pregnancy with medical therapy 2 years ago, presented with spotting bleeding and lower abdominal pain. Her initial beta-hCG level was 11706 mIU/ml and the transvaginal ultrasound examination showed an empty uterine cavity with a gestational sac 8 x 10 x 9 mm in diameter having no fetal pole or yolk sac, located just adjacent to the left uterine cornual region. She was introduced 50 mg of systemic MTX with the presumed diagnosis of interstitial pregnancy. Because the serum beta-hCG level raised to 18654 mIU/ml and a fetal pole with cardiac activity emerged on the ultrasound on the fourth day after MTX injection, laparoscopy was planned. The interstitial pregnancy was successfully treated via laparoscopic cornuotomy with the preservation of the uterus. In advanced interstitial pregnancies with high hCG levels, systemic MTX therapy is expected to be ineffective. Laparoscopic cornuotomy is a minimally invasive and effective method of treatment with the advantage of preserving future fertility.
Le Lous, M; De Chanaud, N; Bourret, A; Senat, M V; Colmant, C; Jaury, P; Tesnière, A; Tsatsaris, V
2017-01-01
Ultrasonography (US) is an essential tool for the diagnosis of acute gynecological conditions. General practice (GP) residents are involved in the first-line management of gynecologic emergencies. They are not familiar with US equipment. Initial training on simulators was conducted.The aim of this study was to evaluate the impact of simulation-based training on the quality of the sonographic images achieved by GP residents 2 months after the simulation training versus clinical training alone. Young GP residents assigned to emergency gynecology departments were invited to a one-day simulation-based US training session. A prospective controlled trial aiming to assess the impact of such training on TVS (transvaginal ultrasound scan) image quality was conducted. The first group included GP residents who attended the simulation training course. The second group included GP residents who did not attend the course. Written consent to participate was obtained from all participants. Images achieved 2 months after the training were scored using standardized quality criteria and compared in both groups. The stress generated by this examination was also assessed with a simple numeric scale. A total of 137 residents attended the simulation training, 26 consented to participate in the controlled trial. Sonographic image quality was significantly better in the simulation group for the sagittal view of the uterus (3.6 vs 2.7, p = 0.01), for the longitudinal view of the right ovary (2.8 vs 1.4, p = 0.027), and for the Morrison space (1.7 vs 0.4, p = 0.034), but the difference was not significant for the left ovary (2.9 vs 1.7, p = 0.189). The stress generated by TVS after 2 months was not different between the groups (6.0 vs 4.8, p = 0.4). Simulation-based training improved the quality of pelvic US images in GP residents assessed after 2 months of experience in gynecology compared to clinical training alone.
Rau, Janina; Tiedemann, Daniela; Sielhorst, Jutta; Tönissen, Anna; Burger, Dominik; Martinsson, Gunilla; Rohn, Karl; Oldenhof, Harriette; Sieme, Harald
2018-06-01
Transvaginal ultrasound-guided aspiration (TUA) is a procedure which can be used for the reduction of twins post-fixation in the mare. The aim of this study was to evaluate the effect of the age of mares and the day of gestation on the outcome of TUA treatment. In 88 mares, diagnosed pregnant with twins, TUA of the yolk sac or allantoic fluid was performed between day 30 and 62 of gestation. Mares were aged 3-22 years. Ultrasonographic examination for a viable singleton pregnancy was performed by referring veterinarians 5-7 days and 4 weeks after TUA. Based on reported findings, effects of age and day of gestation on pregnancy rates were evaluated. Four weeks after TUA, 67% of the cases resulted in a viable singleton pregnancy. Five to 7 days after TUA treatment, the success rate was 74%. The gestational period did not affect the outcome, irrespective of the age of the mare. In contrast, success rates decreased with increasing age of the mares (84% ≤ 7 years vs. 67% 8-14 years vs. 57% ≥ 15 years). In mares aged 8-14 years, a decrease in singleton pregnancies was observed, if TUA was performed after day 35 of gestation. Success rates were slightly higher, if twin vesicles were localized within separate uterine horns (73%) as compared to the same horn (66%). Differences in singleton pregnancy rates were not statistically significant (p > 0.05). TUA was found to be an effective procedure for reduction of twin pregnancies performed at days 30-62 of gestation. Success rates for singleton pregnancies were high for young mares ≤ 7 years old (84%) and middle aged mares treated before day 36 of pregnancy (74%). Duration of pregnancy at the time of TUA did not have a major impact on the outcome. Nevertheless, the procedure should optimally be performed around days 32-35 of pregnancy to allow for the possibility of natural reduction before treatment and rebreeding in case of a total pregnancy loss after TUA. Schattauer GmbH.
Zahalka, Neriman; Sadan, Oscar; Malinger, Gustav; Liberati, Marco; Boaz, Mona; Glezerman, Marek; Rotmensch, Sigi
2005-08-01
Precise determination of fetal head position in labor is a prerequisite for safe instrumental deliveries, and essential for the assessment of labor progress. Recent studies have cast serious doubts on the accuracy of the time-honored digital vaginal examination (DVE) in comparison to transabdominal ultrasound scans (TUS). However, transabdominal imaging is technically difficult with a deeply engaged fetal head in the second stage of labor. We examined the accuracy and time requirements of transvaginal scans (TVS) in the second stage of labor for determination of fetal head position. Sixty laboring women in the second stage of labor with a deeply engaged fetal head were examined by experienced nurse midwives and senior residents. Fetal head position was recorded as "time on a 12-hour clock." Subsequently, TUS and TVS were independently performed by a skilled sonographer. Accuracy and time requirements for all 3 examinations were recorded. Fetal head position could be determined in all cases by TVS, but not in 7 cases and 9 cases by DVE and TUS, respectively (P < .03; P < .008). A discrepancy of 60 degrees or more between the DVE and TUS or TVS was found in 13/60 cases (21.7%) and 14/60 cases (23.3%), respectively. A > or = 90 degrees discrepancy was found in 9/60 cases (15%) and 12/60 cases (20%), respectively (P < .02 for comparison of TUS and TVS). In 5 cases, the digital examination erroneously perceived an occiput posterior position as occiput anterior. No significant differences in fetal head position were detected between TUS and TVS, when the examination was technically feasible. The mean time (+/-SD) required for determining fetal head position was shortest for TVS (8.7 +/- 5.8 seconds) in comparison to DVE (22.7 +/- 14.6 seconds; P < .0001) or TAS (31.7 +/- 19.1 seconds; P < .0001). Transvaginal sonography was the most successful and accurate method for determination of fetal head position in the second stage of labor, and required the least time for performance. We believe that TVS should be routinely performed in the labor room setting for the determination of fetal head position.
Khazendar, S.; Sayasneh, A.; Al-Assam, H.; Du, H.; Kaijser, J.; Ferrara, L.; Timmerman, D.; Jassim, S.; Bourne, T.
2015-01-01
Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. Results: The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). Conclusion: We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered. PMID:25897367
Diagnostic utility of three-dimensional power Doppler ultrasound for postmenopausal bleeding.
Kim, Ari; Lee, Ji Young; Chun, Sungwook; Kim, Heung Yeol
2015-06-01
We evaluated the role of three-dimensional power Doppler ultrasound (3D PD-US) to detect endometrial lesions in women with postmenopausal endometrial bleeding. In this prospective observational study, from January 2009 to November 2012, we recruited 225 postmenopausal women with postmenopausal uterine bleeding who met the study criteria. Women who had hematologic disease, chronic medical diseases, or nonuterine pelvic diseases were excluded. Prior to endometrial biopsy, the patients underwent a baseline transvaginal ultrasound screening. The vascular indices and endometrial volumes were calculated with 3D PD-US and compared with the endometrial histopathology. Among the endometrial histopathologic findings of 174 women, atrophic endometrium was the most common finding (30.5%). Endometrial malignancy was confirmed in 28 cases (16.1%), and endometrial hyperplasia was diagnosed in 17 cases (9.8%). The prevalence of endometrial cancer was high in patients who had endometrial thickness >9.5 mm (p < 0.001) and volume greater than 4.05 mL (p < 0.001). For the endometrial carcinoma only, the cutoff values of vascular index, flow index, and vascular flow index for predicting malignancy were 13.070, 12.610, and 3.764, respectively. For endometrial hyperplasia, endometrial thickness and vascular flow index were significant findings. Endometrial vasculature and volume can be obtained using 3D PD-US. The diagnostic usefulness of 3D PD-US for endometrial diseases is promising in women with postmenopausal endometrial bleeding. Copyright © 2015. Published by Elsevier B.V.
Opmeer, B C; van Doorn, H C; Heintz, A P M; Burger, C W; Bossuyt, P M M; Mol, B W J
2007-01-01
The aim of this study was to evaluate whether the efficiency of the current diagnostic work up following postmenopausal bleeding could be improved by diagnostic strategies that take into account characteristics of the women in addition to the currently recommended transvaginal measurement of endometrial thickness to determine for subsequent histological assessment. Multicenter, prospective cohort study. A university hospital and seven teaching hospitals in the Netherlands. Consecutive women not using hormone replacement therapy, presenting with postmenopausal bleeding. Five hundred and forty women underwent transvaginal sonography, and in case of endometrial thickness (double layer) above 4 mm, subsequent endometrial sampling was performed. Presence of carcinoma was ruled out by the absence of abnormalities in histological specimen or by an uneventful follow up of at least 6 months. Probability of endometrial carcinoma was estimated by multivariable logistic regression models. For each diagnostic strategy, we calculated diagnostic accuracy (area under receiver operating characteristic curve [AUC]), negative predictive value (NPV) and the number of diagnostic procedures. A strategy with transvaginal sonography alone with a fixed threshold incorrectly classified 0.7% of the women as nonmalignant (NPV: 99.3% [98.5-100%]), with 97% sensitivity and 56% specificity. A strategy integrating characteristics of the women with transvaginal sonography could result in less false reassurances (NPV: 99.6% [99.2-100%]), with only marginal decrease in diagnostic procedures, or a minor increase in false reassurances (NPV: 99.0% [98.3-100%]), with a substantial reduction (15-20%) in the procedures. AUCs associated with these strategies could improve from 0.76 (0.73-0.79) for transvaginal sonography alone to 0.90 (0.87-0.93) for the integrated strategy. Taking into account the characteristics of the women could increase the efficiency of the diagnostic work up for postmenopausal bleeding.
Czajkowski, Krzysztof; Sienko, Jacek; Mogilinski, Mariusz; Bros, Magdalena; Szczecina, Roman; Czajkowska, Anna
2007-03-01
To compare the influence of vaginal micronized progesterone and oral dydrogesterone supplementation on uteroplacental circulation in early pregnancy that is complicated by threatened abortion. Randomized, parallel group, double-blind, double dummy-controlled study. Tertiary care university hospital. Fifty-three patients with threatened abortion and a living embryo. Three hundred milligrams of micronized vaginal progesterone or 30 mg of oral dydrogesterone daily supplementation for 6 weeks, serial transvaginal Doppler ultrasound measurement of pulsatility index, resistance index, and systolic/diastolic ratio of the spiral arteries, the uterine arteries, and the intrachorionic area. Uteroplacental blood flow. The study demonstrated that vaginal progesterone administration, but not oral dydrogesterone treatment, results in the decrease in the spiral artery pulsatility and resistance index and systolic/diastolic ratio. Insignificant decrease in pulsatility index and resistance index of the uterine artery was observed at >9 weeks and was not associated with treatment regimen. Dydrogesterone treatment was only accompanied by the decrease in the uterine artery systolic/diastolic ratio. Vaginal progesterone and oral dydrogesterone supplementation have a different influence on the uteroplacental circulation in early pregnancy that is complicated by threatened abortion.
Genetic testing for hereditary cancer predisposition: BRCA1/2, Lynch syndrome, and beyond
Hall, MJ; Obeid, EI; Schwartz, SC; Mantia-Smaldone, G; Forman, AD; Daly, MB
2016-01-01
Obstetrician/gynecologists and gynecologic oncologists serve an integral role in the care of women at increased hereditary risk of cancer. Their contribution includes initial identification of high risk patients, screening procedures like bimanual exam, trans-vaginal ultrasound and endometrial biopsy, prophylaxis via TAH and/or BSO, and chemoprevention. Further, gynecologists also serve a central role in the management of the secondary repercussions of efforts to mitigate increased cancer risks, including vasomotor symptoms, sexual function, bone health, cardiovascular disease, and mental health. The past several years has seen multiple new high and moderate penetrance genes introduced into the clinical care of women at increased risk of gynecologic malignancy. Awareness of these new genes and the availability of new multigene panel tests is critical for providers on the front-line of women’s health. PMID:26812021
Monitoring of stimulated cycles in assisted reproduction (IVF and ICSI).
Kwan, I; Bhattacharya, S; McNeil, A; van Rumste, M M E
2008-04-16
Traditional monitoring of ovarian hyperstimulation during in vitro fertilisation (IVF) treatment has included ultrasonography plus serum estradiol concentration to ensure safe practice by reducing the incidence and severity of ovarian hyperstimulation syndrome (OHSS). The need for intensive monitoring during ovarian stimulation in IVF is controversial. It has been suggested that close monitoring is time consuming, expensive and inconvenient for the woman and simplification of IVF therapy by using ultrasound only should be considered. This systematic review assessed the effects of ovarian monitoring by ultrasound only versus ultrasound plus serum estradiol measurement on IVF outcomes and the occurrence of OHSS in women undergoing stimulated cycles in IVF and intra-cytoplasmic sperm injection (ICSI) treatment. To quantify the effect of monitoring controlled ovarian stimulation in IVF and ICSI cycles with ultrasound plus serum estradiol concentration versus ultrasound only in terms of live birth rates, pregnancy rates and the incidence of OHSS. We searched the Menstrual Disorders and Subfertility Group Specialised Register of controlled trials, Cochrane Central Register of Controlled Trials (CENTRAL) on the latest issue of The Cochrane Library, MEDLINE (1966 to May 2007), EMBASE (1980 to May 2007), CINAHL (1982 to May 2007), the National Research Register, and web-based trial databases such as Current Controlled Trials. There was no language restriction. Additionally all references in the identified trials and background papers were checked and authors were contacted to identify relevant published and unpublished data. Only randomised controlled trials that compared monitoring with ultrasound plus serum estradiol concentration versus ultrasound only in women undergoing ovarian hyperstimulation for IVF and ICSI treatment were included. Two review authors independently examined the electronic search results for relevant trials, extracted data and assessed trial quality. They resolved disagreements by discussion with two other authors. Outcomes data were pooled when appropriate and summary statistics presented when limited data did not allow meta-analysis. Our search strategy identified 1119 potentially eligible reports, of which two met our inclusion criteria. These involved 411 women who underwent controlled ovarian stimulation monitoring. Our primary outcome of live birth rate was not reported in either study. One trial reported clinical pregnancy rate per woman (33% versus 31%; RR 1.07, 95% CI 0.77 to 1.49), the second trial reported clinical pregnancy rate per oocyte retrieval (22% versus 25%). There was no significant difference between the ultrasound plus estradiol group and the ultrasound alone group in the mean number of oocytes retrieved (WMD -0.55, 95% CI -1.79 to 0.69) and the incidence of ovarian hyperstimulation (RR 0.73, 95% CI 0.30 to 1.78) for the two studies. There is no evidence from randomised trials to support cycle monitoring by ultrasound plus serum estradiol as more efficacious than cycle monitoring by ultrasound only on outcomes of live birth and pregnancy rates. A large well-designed randomised controlled trial is needed that reports on live birth rates and pregnancy, with economic evaluation of the costs involved and the views of the women undergoing cycle monitoring. A randomised trial with sufficiently large sample size to test the effects of different monitoring protocols on OHSS, a rare outcome, will pose a great challenge. Until such a trial is considered feasible, cycle monitoring by transvaginal ultrasound plus serum estradiol may need to be retained as a precautionary good practice point.
Lujan, Marla E; Jarrett, Brittany Y; Brooks, Eric D; Reines, Jonathan K; Peppin, Andrew K; Muhn, Narry; Haider, Ehsan; Pierson, Roger A; Chizen, Donna R
2013-05-01
Do the ultrasonographic criteria for polycystic ovaries supported by the 2003 Rotterdam consensus adequately discriminate between the normal and polycystic ovary syndrome (PCOS) condition in light of recent advancements in imaging technology and reliable methods for estimating follicle populations in PCOS? Using newer ultrasound technology and a reliable grid system approach to count follicles, we concluded that a substantially higher threshold of follicle counts throughout the entire ovary (FNPO)-26 versus 12 follicles-is required to distinguish among women with PCOS and healthy women from the general population. The Rotterdam consensus defined the polycystic ovary as having 12 or more follicles, measuring between 2 and 9 mm (FNPO), and/or an ovarian volume (OV) >10 cm(3). Since their initial proposal in 2003, a heightened prevalence of polycystic ovaries has been described in healthy women with regular menstrual cycles, which has questioned the accuracy of these criteria and marginalized the specificity of polycystic ovaries as a diagnostic criterion for PCOS. A diagnostic test study was performed using cross-sectional data, collected from 2006 to 2011, from 168 women prospectively evaluated by transvaginal ultrasonography. Receiver operating characteristic (ROC) curve analyses were performed to determine the appropriate diagnostic thresholds for: (i) FNPO, (ii) follicle counts in a single cross section (FNPS) and (iii) OV. The levels of intra- and inter-observer reliability when five observers used the proposed criteria on 100 ultrasound cases were also determined. Ninety-eight women diagnosed with PCOS by the National Institutes of Health criteria as having both oligo-amenorrhea and hyperandrogenism and 70 healthy female volunteers recruited from the general population. Participants were evaluated by transvaginal ultrasonography at the Royal University Hospital within the Department of Obstetrics, Gynecology and Reproductive Sciences, University of Saskatchewan (Saskatoon, SK, Canada) and in the Division of Nutritional Sciences' Human Metabolic Research Unit, Cornell University (Ithaca, NY, USA). Diagnostic potential for PCOS was highest for FNPO (0.969), followed by FNPS (0.880) and OV (0.873) as judged by the area under the ROC curve. An FNPO threshold of 26 follicles had the best compromise between sensitivity (85%) and specificity (94%) when discriminating between controls and PCOS. Similarly, an FNPS threshold of nine follicles had a 69% sensitivity and 90% specificity, and an OV of 10 cm(3) had a 81% sensitivity and 84% specificity. Levels of intra-observer reliability were 0.81, 0.80 and 0.86 when assessing FNPO, FNPS and OV, respectively. Inter-observer reliability was 0.71, 0.72 and 0.82, respectively. Thresholds proposed by this study should be limited to use in women aged between 18 and 35 years. Polycystic ovarian morphology has excellent diagnostic potential for detecting PCOS. FNPO have better diagnostic potential and yield greater diagnostic confidence compared with assessments of FNPS or OV. Whenever possible, images throughout the entire ovary should be collected for the ultrasonographic evaluation of PCOS. This study was funded by Cornell University and fellowship awards from the Saskatchewan Health Research Foundation and Canadian Institutes of Health Research. The authors have no conflict of interests to disclose.
Wei, Dechao; Han, Yili; Li, Mingchuan; Wang, Yongxing; Chen, Yatong; Luo, Yong; Jiang, Yongguang
2016-06-11
Among the different organs used for NOTES (natural orifice translumenal endoscopic surgery) technique, the transvaginal approach may be the optimal choice because of a simple and secure closure of colpotomy site. Pure and hybrid NOTES transvaginal operations were routinely performed via transperitoneal access. In this study, we investigate the safety and feasibility of pure retroperitoneal natural orifice translumenal endoscopic surgery (NOTES) transvaginal nephrectomy using conventional laparoscopic techniques in a porcine model. Six female pigs, weighing an average of 30 kg, were used in this study. Under general anesthesia, pure retroperitoneal NOTES transvaginal nephrectomy was conducted using standard laparoscopic instruments. Posterolateral colpotomy was performed, and the incision was enlarged laterally using blunt dissection and pneumatic dilation. A single-port device was inserted to construct the operative channel. The retroperitoneal space was created using sharp and blunt dissection under endoscopic guidance up to the level of the kidney. Dissection and removal of the kidney were performed according to standard surgical procedure, and the colpotomy site was closed using interrupted sutures. The survival and complications were observed 1 week postoperatively. Our results showed that two cases failed because of peritoneal rupture. One case was successful, but required the assistance of an extra 5 mm laparoscopic trocar inserted in the flank. Three cases of pure retroperitoneal NOTES transvaginal nephrectomy were completed, and survived 1 week after the operation. In these three cases, no intra- or postoperative complications were observed. All findings confirmed the safety and feasibility of the retroperitoneal pure retroperitoneal NOTES transvaginal nephrectomy using standard laparoscopic instruments, which suggested the possibility of clinical application in human beings in the future.
Whiteley, M S; Dos Santos, S J; Harrison, C C; Holdstock, J M; Lopez, A J
2015-12-01
To assess the suitability of transvaginal duplex ultrasonography to identify pathological reflux in the ovarian and internal iliac veins in women. A retrospective study of patients treated in 2011 and 2012 was performed in a specialised vein clinic. Diagnostic transvaginal duplex ultrasonography in women presenting with symptoms or signs of pelvic vein reflux were compared with the outcomes of treatment from pelvic vein embolisation. A repeat transvaginal duplex ultrasonography was performed 6 weeks later by a blinded observer and any residual reflux was identified. Results from 100 sequential patients were analysed. Mean age 44.2 years (32-69) with mode average parity of 3 (0-5 deliveries). Pre-treatment, 289/400 veins were refluxing (ovarian - 29 right, 81 left; internal iliac - 93 right, 86 left). Coil embolisation was successful in 86/100 patients and failed partially in 14/100 - 5 due to failure to cannulate the target vein. One false-positive diagnosis was made. Currently there is no accepted gold standard for pelvic vein incompetence. Comparing transvaginal duplex ultrasonography with the outcome from selectively treating the veins identified as having pathological reflux with coil embolisation, there were no false-negative diagnoses and only one false-positive. This study suggests that transvaginal duplex ultrasonography could be the gold standard in assessing pelvic vein reflux. © The Author(s) 2014.
[Ultrasonography in acute pelvic pain].
Kupesić, Sanja; Aksamija, Alenka; Vucić, Niksa; Tripalo, Ana; Kurjak, Asim
2002-01-01
Acute pelvic pain may be the manifestation of various gynecologic and non-gynecologic disorders from less alarming rupture of the follicular cyst to life threatening conditions such as rupture of ectopic pregnancy or perforation of inflamed appendix. In order to construct an algorithm for differential diagnosis we divide acute pelvic pain into gynecologic and non-gynecologic etiology, which is than subdivided into gastrointestinal and urinary causes. Appendicitis is the most common surgical emergency and should always be considered in differential diagnosis if appendix has not been removed. Apart of clinical examination and laboratory tests, an ultrasound examination is sensitive up to 90% and specific up to 95% if graded compression technique is used. Still it is user-depended and requires considerable experience in order to perform it reliably. Meckel's diverticulitis, acute terminal ileitis, mesenteric lymphadenitis and functional bowel disease are conditions that should be differentiated from other causes of low abdominal pain by clinical presentation, laboratory and imaging tests. Dilatation of renal pelvis and ureter are typical signs of obstructive uropathy and may be efficiently detected by ultrasound. Additional thinning of renal parenchyma suggests long-term obstructive uropathy. Ruptured ectopic pregnancy, salpingitis and hemorrhagic ovarian cysts are three most commonly diagnosed gynecologic conditions presenting as an acute abdomen. Degenerating leiomyomas and adnexal torsion occur less frequently. For better systematization, gynecologic causes of acute pelvic pain could be divided into conditions with negative pregnancy test and conditions with positive pregnancy test. Pelvic inflammatory disease may be ultrasonically presented with numerous signs such as thickening of the tubal wall, incomplete septa within the dilated tube, demonstration of hyperechoic mural nodules, free fluid in the "cul-de-sac" etc. Color Doppler ultrasound contributes to more accurate diagnosis of this entity since it enables differentiation between acute and chronic stages based on analysis of the vascular resistance. Hemorrhagic ovarian cysts may be presented by variety of ultrasound findings since intracystic echoes depend upon the quality and quantity of the blood clots. Color Doppler investigation demonstrates moderate to low vascular resistance typical of luteal flow. Leiomyomas undergoing degenerative changes are another cause of acute pelvic pain commonly present in patients of reproductive age. Color flow detects regularly separated vessels at the periphery of the leiomyoma, which exhibit moderate vascular resistance. Although the classic symptom of endometriosis is chronic pelvic pain, in some patients acute pelvic pain does occur. Most of these patients demonstrate an endometrioma or "chocolate" cyst containing diffuse carpet-like echoes. Sometimes, solid components may indicate even ovarian malignancy, but if color Doppler ultrasound is applied it is less likely to obtain false positive results. One should be aware that pericystic and/or hillar type of ovarian endometrioma vascularization facilitate correct recognition of this entity. Pelvic congestion syndrome is another condition that can cause an attack of acute pelvic pain. It is usually consequence of dilatation of venous plexuses, arteries or both systems. By switching color Doppler gynecologist can differentiate pelvic congestion syndrome from multilocular cysts, pelvic inflammatory disease or adenomyosis. Ovarian vein thrombosis is a potentially fatal disorder occurring most often in the early postpartal period. Hypercoagulability, infection and stasis are main etiologic factors, and transvaginal color Doppler ultrasound is an excellent diagnostic tool to diagnose it. Acute pelvic pain may occur even in normal intrauterine pregnancy. This may be explained by hormonal changes, rapid growth of the uterus and increased blood flow. Ultrasound is mandatory for distinguishing normal intrauterine pregnancy from threatened or spontaneous abortion, ectopic pregnancy and other complications that may occur in patients with positive pregnancy test. Incomplete abortion is visualized as thickened and irregular endometrial echo with certain amount of intracavitary fluid. If applied, color Doppler ultrasound reveals low vascular resistance signals in richly perfused intracavitary area. Transvaginal sonography has high sensitivity and specificity in visualization of uterine and adnexal signs of ectopic pregnancy. Color Doppler examination may aid in detection of the peritrophoblastic flow. Furthermore, it facilitates detection of ectopic living embryo, tubal ring or unspecific adnexal tumor. Corpus luteum cysts and leiomyomas are another cause of pelvic pain during pregnancy, which can be correctly diagnosed by ultrasound. Detection of uterine dehiscence and rupture in patients with history of prior surgical intervention on uterine wall relies exclusively on correct ultrasound diagnosis. In patients with placental abruption sonographer detects hypoechoic complex representing either retroplacental hematoma, subchorionic hematoma or subamniotic hemorrhage. In closing, ultrasound has already become important and easily available tool which can efficiently recognize patients with possibly threatening conditions of different origins.
Effects of repeated transvaginal aspiration of immature follicles on mare health and ovarian status.
Velez, I C; Arnold, C; Jacobson, C C; Norris, J D; Choi, Y H; Edwards, J F; Hayden, S S; Hinrichs, K
2012-12-01
Transvaginal ultrasound-guided follicle aspiration (TVA) is performed clinically but there is little information available on complications associated with this procedure. It is possible that TVA is associated with damage to the ovary and may induce peritonitis or peritoneal adhesions. This study was conducted to determine the effect of repeated TVA on mare health and ovarian status. Thirty-two mares were used for oocyte recovery via repeated TVA over a 3 year period; different mares were used each year. In Year 1, ovarian status was monitored in 11 mares by transrectal palpation and ultrasonography. In Year 2, 6 of 11 mares underwent abdominocentesis and were examined by laparoscopy after one TVA and again after multiple TVAs. In Year 3, 10 mares underwent multiple TVAs with either a 15 or a 12 gauge needle and the ovaries were removed for examination. Four hundred and twenty-seven aspiration sessions (390 via TVA and 37 via needle placement through the flank) and 3202 follicle punctures (3161 TVA and 41 flank) were performed. One mare developed an ovarian abscess. Transient rectal bleeding was evident after 16% of TVA sessions. No adhesions were found on laparoscopic or gross examination of ovaries and there were minimal changes on histological evaluation. Follicle aspiration carries a small possibility (< 0.5%) of ovarian abscess formation. There is a possibility of rectal abrasion or puncture but little gross or histological damage to the ovary. These results provide a basis for using prophylactic administration of antibiotics after TVA and for advising mare owners of the rare but potential complications associated with the procedure.
ACR appropriateness criteria(®) on abnormal vaginal bleeding.
Bennett, Genevieve L; Andreotti, Rochelle F; Lee, Susanna I; Dejesus Allison, Sandra O; Brown, Douglas L; Dubinsky, Theodore; Glanc, Phyllis; Mitchell, Donald G; Podrasky, Ann E; Shipp, Thomas D; Siegel, Cary Lynn; Wong-You-Cheong, Jade J; Zelop, Carolyn M
2011-07-01
In evaluating a woman with abnormal vaginal bleeding, imaging cannot replace definitive histologic diagnosis but often plays an important role in screening, characterization of structural abnormalities, and directing appropriate patient care. Transvaginal ultrasound (TVUS) is generally the initial imaging modality of choice, with endometrial thickness a well-established predictor of endometrial disease in postmenopausal women. Endometrial thickness measurements of ≤5 mm and ≤4 mm have been advocated as appropriate upper threshold values to reasonably exclude endometrial carcinoma in postmenopausal women with vaginal bleeding; however, the best upper threshold endometrial thickness in the asymptomatic postmenopausal patient remains a subject of debate. Endometrial thickness in a premenopausal patient is a less reliable indicator of endometrial pathology since this may vary widely depending on the phase of menstrual cycle, and an upper threshold value for normal has not been well-established. Transabdominal ultrasound is generally an adjunct to TVUS and is most helpful when TVUS is not feasible or there is poor visualization of the endometrium. Hysterosonography may also allow for better delineation of both the endometrium and focal abnormalities in the endometrial cavity, leading to hysteroscopically directed biopsy or resection. Color and pulsed Doppler may provide additional characterization of a focal endometrial abnormality by demonstrating vascularity. MRI may also serve as an important problem-solving tool if the endometrium cannot be visualized on TVUS and hysterosonography is not possible, as well as for pretreatment planning of patients with suspected endometrial carcinoma. CT is generally not warranted for the evaluation of patients with abnormal bleeding, and an abnormal endometrium incidentally detected on CT should be further evaluated with TVUS. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Gerges, B; Mongelli, M; Casikar, I; Bignardi, T; Condous, G
2017-08-01
In light of recent statements from the United States Food and Drug Administration warning against the use of power morcellation of uterine leiomyomas during laparoscopy, we sought to evaluate the use of preoperative two- (2D) and three- (3D) dimensional transvaginal ultrasound (US) assessment of uterine volume to predict the need for morcellation in women undergoing laparoscopic hysterectomy (LH). This was a prospective observational study performed between October 2008 and November 2011 in a tertiary referral laparoscopic unit. All women scheduled to undergo LH were included and underwent detailed preoperative transvaginal US. Uterine volumes were calculated using 2D-US measurements (ellipsoid formula), and using Virtual Organ Computer-aided AnaLysis (VOCAL™) having acquired 3D-US volumes of the uterus. Age, parity, need to morcellate and final uterine dry weight at histology were recorded. The estimated uterine volumes were then incorporated into a previously published logistic regression model to predict the need to morcellate for both nulliparous and parous women. The probability threshold cut-off of 0.14 (95% sensitivity) was evaluated in terms of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and likelihood ratios (LRs). The performance of the models incorporating 2D- and 3D-US calculations were compared with 2D- and 3D-US-generated volumes alone, using receiver-operating characteristics (ROC) curves. Of 76 women who underwent LH during the study period, 79% (n = 60) had complete background and 3D-US data. Their mean age was 43.7 years, 91.7% were parous and 35% underwent morcellation. The greatest uterine volume that did not require morcellation was 404 mL estimated using 3D-US, which corresponded to a uterine volume of 688.8 mL using 2D-US. The smallest uterine volume that required morcellation was 118.9 mL using 3D-US, which corresponded to a uterine volume of 123.4 mL using 2D-US. The 3D-US uterine volume for parous women with a sensitivity of 95% based on ROC-curve analysis was approximately 120 mL, which equated to a predicted probability of morcellation cut-off of 0.14. For this cut-off, specificity was 55.00%, PPV was 51.35%, NPV was 95.65%, LR+ was 2.11 and LR- was 0.09. Areas under the ROC curves for the morcellation logistic regression model were 0.769 (95% CI, 0.653-0.886) and 0.586 (95% CI, 0.419-0.753) using uterine volumes obtained by 3D-US and by 2D-US, respectively, and they were 0.938 (95% CI, 0.879-0.996) and 0.815 (95% CI, 0.681-0.948) using 3D-US and 2D-US volumes alone. The need to morcellate can be predicted preoperatively using 3D-US uterine volumes obtained by transvaginal US with a fair degree of accuracy. Uteri with volumes smaller than 120 mL at 3D-US are very unlikely to require morcellation. The incorporation of 3D-US-estimated uterine volume into the previously published logistic regression model does not seem to confer any significant improvement when compared with 3D-US uterine volume alone to predict the need to morcellate in women undergoing total LH. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Koning, Irene V.; Groenenberg, Irene A. L.; Gotink, Anniek W.; Willemsen, Sten P.; Gijtenbeek, Manon; Dudink, Jeroen; Go, Attie T. J. I.; Reiss, Irwin K. M.; Steegers, Eric A. P.; Steegers-Theunissen, Régine P. M.
2015-01-01
We aimed to investigate whether periconceptional maternal folate status affects human embryonic cerebellar size and growth trajectories. In a prospective periconceptional cohort participants filled out questionnaires and received weekly transvaginal 3D-ultrasounds between 7+0 and 12+6 weeks gestational age (GA). Viable non-malformed singleton pregnancies were selected for cerebellar measurements; transcerebellar diameter, (TCD), left and right cerebellar diameters (LCD, RCD). Linear mixed models were performed to estimate associations between questionnaire data on the timing of maternal folic acid supplement initiation and longitudinal cerebellar measurements as a function of crown-rump length (CRL) and GA. Maternal red blood cell folate concentrations were analysed before 8 weeks GA to validate the associations. A total of 263 serial high quality three-dimensional ultrasound scans of 135 pregnancies were studied. Preconceptional compared to postconceptional initiation of folic acid use was associated with slightly larger cerebellar diameters per millimetre increase of CRL (TCD: β = 0.260mm, 95%CI = 0.023–0.491, p<0.05; LCD: β = 0.171mm, 95%CI = 0.038–0.305, p<0.05; RCD: β = 0.156mm, 95%CI = 0.032–0.280, p<0.05) and with proportional cerebellar growth (TCD/CRL:β = 0.015mm/mm, 95%CI = 0.005–0.024, p<0.01; LCD/CRL:β = 0.012mm/mm, 95%CI = 0.005–0.018, p<0.01; RCD/CRL:β = 0.011mm/mm, 95%CI = 0.005–0.017, p<0.01). Cerebellar growth was significantly highest in the third quartile of maternal red blood cell folate levels (1538–1813 nmol/L). These first findings show that periconceptional maternal folate status is associated with human embryonic cerebellar development. Implications of these small but significant variations for fetal cerebellar growth trajectories and the child’s neurodevelopmental outcome are yet unknown and warrant further investigation. PMID:26491876
Singh, Awadhesh Kumar; Singh, Ritu
2015-01-01
Several studies over the past decade have now consistently indicated that the serum anti-Mullerian hormone (AMH) levels are at least 2–3-fold higher in the patients with polycystic ovary syndrome (PCOS), which also corresponds to the increased number of AMH producing preantral and small antral follicles. Moreover, AMH levels have been found to be associated in direct proportion to the follicle numbers per ovary or antral follicular count, assessed by the transvaginal ultrasound (TVS). Furthermore, AMH correlates directly with the rising serum testosterone and luteinizing hormone levels in PCOS. Hence, serum AMH in women with oligo-anovulation and/or hyperandrogenemia could indicate the presence of underlying PCOS, when reliable TVS is not feasible, or not acceptable, either due to the virginal status or psycho-social issue. In addition, the imaging quality of abdominal ultrasound is often impaired by obesity, which typically occurs in PCOS women. Indeed, PCOS occurs most commonly in young females who cannot be subjected to invasive TVS for various reasons; therefore, a desirable alternative to TVS is urgently required to diagnose the most prevalent endocrine abnormality of young women. This review will analyze the currently available evidence regarding the role of AMH in the diagnosis of PCOS. PMID:26693422
Genetic testing for hereditary cancer predisposition: BRCA1/2, Lynch syndrome, and beyond.
Hall, M J; Obeid, E I; Schwartz, S C; Mantia-Smaldone, G; Forman, A D; Daly, M B
2016-03-01
Obstetrician/gynecologists and gynecologic oncologists serve an integral role in the care of women at increased hereditary risk of cancer. Their contribution includes initial identification of high risk patients, screening procedures like bimanual exam, trans-vaginal ultrasound and endometrial biopsy, prophylaxis via TAH and/or BSO, and chemoprevention. Further, gynecologists also serve a central role in the management of the secondary repercussions of efforts to mitigate increased cancer risks, including vasomotor symptoms, sexual function, bone health, cardiovascular disease, and mental health. The past several years has seen multiple new high and moderate penetrance genes introduced into the clinical care of women at increased risk of gynecologic malignancy. Awareness of these new genes and the availability of new multi-gene panel tests is critical for providers on the front-line of women's health. Copyright © 2016 Elsevier Inc. All rights reserved.
Postmenopausal pregnancy? Evaluation of elevated hCG in a 59-year-old woman.
Basham, Mary Margaret; Bryan, Teresa
2017-06-05
Slightly elevated serum human chorionic gonadotropin (hCG) can be a normal finding in postmenopausal women. We report a case of a 59-year-old woman with a history of abnormal uterine bleeding who presented with a concern for pregnancy after developing nausea and vomiting a few weeks after unprotected intercourse. Although pregnancy was extremely unlikely, hCG was obtained in order to reassure the patient since she reported that her mother conceived at the age of 60. Serum hCG was positive, prompting concern for malignancy versus pregnancy. Stable serum hCG levels, elevated follicle-stimulating hormone and negative transvaginal ultrasound ruled out both malignancy and pregnancy. Positive serum pregnancy test and hCG elevation was attributed to normal postmenopausal state. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
The prevalence of phenotypic subgroups in Greek women with polycystic ovarian syndrome.
Vaggopoulos, V; Trakakis, E; Panagopoulos, P; Basios, G; Salloum, I; Christodoulaki, C; Chrelias, C
2013-01-01
Since 2003, when the American Society for Reproductive Medicine (ASRM) and European Society of Human Reproduction and Embryology (ESHRE) sponsored consensus established criteria for polycystic ovarian syndrome (PCOS) diagnosis, the phenotypic spectrum of the syndrome has been significantly broadened. This survey makes an effort to distinguish PCOS according to phenotypic expression and to estimate its prevalence in a Greek population. Greek women from 18 to 35 years of age, who visited the outpatient department, claiming either irregular menstruation (oligo- or anovulation, OA) or clinical manifestations of hyperandrogenemia (HA) were recruited. They gave full disease history and underwent clinical examination, including transvaginal ultrasound (TVUS) scan to identify PCO morphology. Blood samples were collected to perform hormonal and metabolic analyses. Acute or chronic disorders were excluded. Finally, 266 PCOS women constituted the study population. The full-blown phenotype (HA+OA+PCO) is the predominant phenotype in this Greek population.
Guerriero, S; Ajossa, S; Minguez, J A; Jurado, M; Mais, V; Melis, G B; Alcazar, J L
2015-11-01
To review the diagnostic accuracy of transvaginal ultrasound (TVS) in the preoperative detection of endometriosis in the uterosacral ligaments (USL), rectovaginal septum (RVS), vagina and bladder in patients with clinical suspicion of deep infiltrating endometriosis (DIE). An extensive search was performed in MEDLINE (PubMed) and EMBASE for studies published between January 1989 and December 2014. Studies were considered eligible if they reported on the use of TVS for the preoperative detection of endometriosis in the USL, RVS, vagina and bladder in women with clinical suspicion of DIE using the surgical data as a reference standard. Study quality was assessed using the PRISMA guidelines and QUADAS-2 tool. Of the 801 citations identified, 11 studies (n = 1583) were considered eligible and were included in the meta-analysis. For detection of endometriosis in the USL, the overall pooled sensitivity and specificity of TVS were 53% (95%CI, 35-70%) and 93% (95%CI, 83-97%), respectively. The pretest probability of USL endometriosis was 54%, which increased to 90% when suspicion of endometriosis was present after TVS examination. For detection of endometriosis in the RVS, the overall pooled sensitivity and specificity were 49% (95%CI, 36-62%) and 98% (95%CI, 95-99%), respectively. The pretest probability of RVS endometriosis was 24%, which increased to 89% when suspicion of endometriosis was present after TVS examination. For detection of vaginal endometriosis, the overall pooled sensitivity and specificity were 58% (95%CI, 40-74%) and 96% (95%CI, 87-99%), respectively. The pretest probability of vaginal endometriosis was 17%, which increased to 76% when suspicion of endometriosis was present after TVS assessment. Substantial heterogeneity was found for sensitivity and specificity for all these locations. For detection of bladder endometriosis, the overall pooled sensitivity and specificity were 62% (95%CI, 40-80%) and 100% (95%CI, 97-100%), respectively. Moderate heterogeneity was found for sensitivity and specificity for bladder endometriosis. The pretest probability of bladder endometriosis was 5%, which increased to 92% when suspicion of endometriosis was present after TVS assessment. Overall diagnostic performance of TVS for detecting DIE in uterosacral ligaments, rectovaginal septum, vagina and bladder is fair with high specificity. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Yin, Fu-Fen; Wang, Ning; Wang, You-Lin; Bi, Xiao-Ning; Xu, Xiao-Hui; Wang, Yan-Kui
2015-01-01
Bladder leiomyoma is a rare benign tumor and it could be easily misdiagnosed with many other pelvic diseases, especially obstetrical and gynecological diseases; abdominal, laparoscopic, and transurethral resection of bladder leiomyoma have been reported. Herein, we present a case of bladder leiomyoma misdiagnosed with a vaginal mass preoperatively; the mass was isolated, enucleated from the bladder neck, and removed transvaginally; to the best of our knowledge, this is the first case of intramural leiomyoma of bladder neck that has been enucleated transvaginally only without cystotomy. PMID:26693368
Roberts, V H J; Morgan, T K; Bednarek, P; Morita, M; Burton, G J; Lo, J O; Frias, A E
2017-12-01
Does the use of a vascular contrast agent facilitate earlier detection of maternal flow to the placental intervillous space (IVS) in the first trimester of pregnancy? Microvascular filling of the IVS was demonstrated by contrast-enhanced ultrasound from 6 weeks of gestation onwards, earlier than previously believed. During placental establishment and remodeling of maternal spiral arteries, endovascular trophoblast cells invade and accumulate in the lumen of these vessels to form 'trophoblast plugs'. Prior evidence from morphological and Doppler ultrasound studies has been conflicting as to whether the spiral arteries are completely plugged, preventing maternal blood flow to the IVS until late in the first trimester. Uteroplacental flow was examined across the first trimester in human subjects given an intravenous infusion of lipid-shelled octofluoropropane microbubbles with ultrasound measurement of destruction and replenishment kinetics. We also performed a comprehensive histopathological correlation using two separately archived uteroplacental tissue collections to evaluate the degree of spiral artery plugging and evaluate remodeling of the upstream myometrial radial and arcurate arteries. Pregnant women (n = 34) were recruited in the first trimester (range: 6+3 to 13+6 weeks gestation) for contrast-enhanced ultrasound studies with destruction-replenishment analysis of signal intensity for assessment of microvascular flux rate. Histological samples from archived in situ (Boyd Collection, n = 11) and fresh first, second, and third trimester decidual and post-hysterectomy uterine specimens (n = 16) were evaluated by immunohistochemistry (using markers of epithelial, endothelial and T-cells, as well as cell adhesion and proliferation) and ultrastructural analysis. Contrast agent entry into the IVS was visualized as early as 6+3 weeks of gestation with some variability in microvascular flux rate noted in the 6-7+6 week samples. Spiral artery plug canalization was observed from 7 weeks with progressive disintegration thereafter. Of note, microvascular flux rate did not progressively increase until 13 weeks, which suggests that resistance to maternal flow in the early placenta may be mediated more proximally by myometrial radial arteries that begin remodeling at the end of the first trimester. Gestational age was determined by crown-rump length measurements obtained by transvaginal ultrasound on the day of contrast-enhanced imaging studies, which may explain the variability in the earliest gestational age samples due to the margin of error in this type of measurement. Our comprehensive in situ histological analysis, in combination with the use of an in vivo imaging modality that has the sensitivity to permit visualization of microvascular filling, has allowed us to reveal new evidence in support of increasing blood flow to the IVS from 6 weeks of gestation. Histologic review suggested the mechanism may be blood flow through capillary-sized channels that form through the loosely cohesive 'plugs' by 7 weeks gestation. However, spiral artery remodeling on its own did not appear to explain why there is significantly more blood flow at 13 weeks gestation. Histologic studies suggest it may be related to radial artery remodeling, which begins at the end of the first trimester. This project was supported by the Oregon Health and Science University Knight Cardiovascular Institute, Center for Developmental Health and the Struble Foundation. There are no competing interests. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
Carmina, Enrico; Fruzzetti, Franca; Lobo, Roger A
2018-04-01
Since features of polycystic ovary syndrome (PCOS) have been found to be prevalent in women with functional hypothalamic amenorrhea (FHA), we wished to determine what happens to these features after recovery of menstrual function in FHA Design: Prospective cohort study. Twenty-eight women with FHA and 30 age-matched ovulatory controls were studied. Twenty-eight women with FHA and 30 age-matched ovulatory controls were studied. We measured serum estradiol, LH, FSH, testosterone, DHEAS, anti-Mullerian hormone (AMH), body mass index, and ovarian morphology on transvaginal ultrasound. At baseline, 12 of the 28 women (43%) had increased AMH (>4.7 ng/mL), and higher testosterone and larger ovaries compared to the other 16 women with normal AMH. One year after recovery of menstrual function, in the 12 women with increased AMH, serum AMH, testosterone and ovarian size decreased, while LH and estradiol increased. At one year, only one of the 12 women in the high AMH group developed clinical features of PCOS. In the majority of women with FHA who have PCOS-like features, these features may be due to the hypothalamic state and appear to be reversible. Few women may develop clinical PCOS after recovery.
First trimester size charts of embryonic brain structures.
Gijtenbeek, M; Bogers, H; Groenenberg, I A L; Exalto, N; Willemsen, S P; Steegers, E A P; Eilers, P H C; Steegers-Theunissen, R P M
2014-02-01
Can reliable size charts of human embryonic brain structures be created from three-dimensional ultrasound (3D-US) visualizations? Reliable size charts of human embryonic brain structures can be created from high-quality images. Previous studies on the visualization of both the cavities and the walls of the brain compartments were performed using 2D-US, 3D-US or invasive intrauterine sonography. However, the walls of the diencephalon, mesencephalon and telencephalon have not been measured non-invasively before. Last-decade improvements in transvaginal ultrasound techniques allow a better visualization and offer the tools to measure these human embryonic brain structures with precision. This study is embedded in a prospective periconceptional cohort study. A total of 141 pregnancies were included before the sixth week of gestation and were monitored until delivery to assess complications and adverse outcomes. For the analysis of embryonic growth, 596 3D-US scans encompassing the entire embryo were obtained from 106 singleton non-malformed live birth pregnancies between 7(+0) and 12(+6) weeks' gestational age (GA). Using 4D View (3D software) the measured embryonic brain structures comprised thickness of the diencephalon, mesencephalon and telencephalon, and the total diameter of the diencephalon and mesencephalon. Of 596 3D scans, 161 (27%) high-quality scans of 79 pregnancies were eligible for analysis. The reliability of all embryonic brain structure measurements, based on the intra-class correlation coefficients (ICCs) (all above 0.98), was excellent. Bland-Altman plots showed moderate agreement for measurements of the telencephalon, but for all other measurements the agreement was good. Size charts were constructed according to crown-rump length (CRL). The percentage of high-quality scans suitable for analysis of these brain structures was low (27%). The size charts of human embryonic brain structures can be used to study normal and abnormal development of brain development in future. Also, the effects of periconceptional maternal exposures, such as folic acid supplement use and smoking, on human embryonic brain development can be a topic of future research. This study was supported by the Department of Obstetrics and Gynaecology of the Erasmus University Medical Center. M.G. was supported by an additional grant from the Sophia Foundation for Medical Research (SSWO grant number 644). No competing interests are declared.
Overbeek, Annelies; van den Berg, Marleen H; Kremer, Leontien C M; van den Heuvel-Eibrink, Marry M; Tissing, Wim J E; Loonen, Jacqueline J; Versluys, Birgitta; Bresters, Dorine; Kaspers, Gertjan J L; Lambalk, Cornelis B; van Leeuwen, Flora E; van Dulmen-den Broeder, Eline
2012-08-23
Advances in childhood cancer treatment over the past decades have significantly improved survival, resulting in a rapidly growing group of survivors. However, both chemo- and radiotherapy may adversely affect reproductive function. This paper describes the design and encountered methodological challenges of a nationwide study in the Netherlands investigating the effects of treatment on reproductive function, ovarian reserve, premature menopause and pregnancy outcomes in female childhood cancer survivors (CCS), the DCOG LATER-VEVO study. The study is a retrospective cohort study consisting of two parts: a questionnaire assessing medical, menstrual, and obstetric history, and a clinical assessment evaluating ovarian and uterine function by hormonal analyses and transvaginal ultrasound measurements. The eligible study population consists of adult female 5-year survivors of childhood cancer treated in the Netherlands, whereas the control group consists of age-matched sisters of the participating CCS. To date, study invitations have been sent to 1611 CCS and 429 sister controls, of which 1215 (75%) and 333 (78%) have responded so far. Of these responders, the majority consented to participate in both parts of the study (53% vs. 65% for CCS and sister controls respectively). Several challenges were encountered involving the study population: dealing with bias due to the differences in characteristics of several types of (non-) participants and finding an adequately sized and well-matched control group. Moreover, the challenges related to the data collection process included: differences in response rates between web-based and paper-based questionnaires, validity of self-reported outcomes, interpretation of clinical measurements of women using hormonal contraceptives, and inter- and intra-observer variation of the ultrasound measurements. The DCOG LATER-VEVO study will provide valuable information about the reproductive potential of paediatric cancer patients as well as long-term survivors of childhood cancer. Other investigators planning to conduct large cohort studies on late effects may encounter similar challenges as those encountered during this study. The solutions to these challenges described in this paper may be useful to these investigators. NTR2922; http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=2922
Gerntke, Carina Isabel; Kersten, Jan Felix; Schön, Gerhard; Mann, Oliver; Stark, Michael; Benhidjeb, Tahar
2016-04-01
Over the past 8 years, natural orifice transluminal endoscopic surgery (NOTES) has developed from preclinical to routine clinical practice. However, there are still concerns regarding the transvaginal approach. In our survey, we were interested in females with a professional medical background, thus having at least a basic medical understanding, which might discriminate between objective and subjective concerns. A questionnaire with 14 items was distributed among 1895 female physicians and nursing and administration staff of the University Medical Center Hamburg-Eppendorf. In addition, a qualitative literature review was performed. Data analysis was carried out using statistical package R version 2.15.0. The questionnaire was answered anonymously by 553 employees (29%). Fifty-seven percent were nurses, 18.6% belonged to administration, and 17% were physicians. A total of 63.1% of our respondents would choose the transvaginal NOTES technique for an assumed ovariectomy, while only 30.4% would choose this access for cholecystectomy. Doubts regarding transvaginal NOTES were related to sexual dysfunction (44.8%), its experimental nature (43.8%), future pregnancies (36.8%), and ethical reasons (30.3%). The literature review showed that women's perception of the transvaginal access is documented very heterogeneously and therefore difficult to compare. Despite the good reported results of NOTES and the medical background of the surveyed female employees, our study and the literature review clearly shows that there are fears regarding the transvaginal access, which might be a result of limited information. More accurate explanation of the available methods by the attending surgeon can lead to a better choice of the patient's preferred method. © The Author(s) 2015.
Koo, Kevin; Gormley, E Ann
2017-02-01
Prompted by patients' changing perceptions of transvaginal mesh, this study examines how mesh has been reported in the news following the 2011 US Food and Drug Administration (FDA) updated notification about the use of mesh in the treatment of pelvic organ prolapse. Two national newspaper databases were queried for articles discussing transvaginal mesh published within 3 years of the FDA announcement. Content analysis included headline subjects, mesh-related complications, quoted sources, and the FDA recommendations. To determine whether more widely read sources publish higher quality reporting, a subgroup analysis was conducted based on newspaper circulation. Ninety-five articles met inclusion criteria. Mesh-related litigation was the most common headline subject (36 articles, 38%), and 54% of all articles referenced legal action. Fifty-seven articles (60%) cited at least one mesh-related complication. Only 18 articles (19%) quoted surgeons who use transvaginal mesh. For the FDA update, 40% of articles that first reported the announcement accurately specified that it applies to mesh for prolapse, not incontinence. This ambiguity persisted: half of all articles cited the warning, but only 23% distinguished between prolapse and incontinence. Higher newspaper circulation did not significantly improve the quality of reporting about the content or context of the FDA's recommendations. Despite frequent media coverage of transvaginal mesh and its complications since 2011, very few news sources that cited the FDA warning distinguished between prolapse and incontinence. Given prevalent reporting of mesh-related litigation, the findings raise concern about how patients perceive the safety and efficacy of transvaginal mesh, regardless of indication. Neurourol. Urodynam. 36:329-332, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Natural history of vasa previa across gestation using a screening protocol.
Rebarber, Andrei; Dolin, Cara; Fox, Nathan S; Klauser, Chad K; Saltzman, Daniel H; Roman, Ashley S
2014-01-01
The purpose of this study was to estimate the prevalence and persistence rate of vasa previa in at-risk pregnancies using a standardized screening protocol. We conducted a descriptive study of patients with a diagnosis of vasa previa from a single ultrasound unit between June 2005 and June 2012. Vasa previa was defined as a fetal vessel within 2 cm of the internal cervical os on transvaginal sonography. Screening for vasa previa using transvaginal sonography with color flow mapping was performed routinely in the following situations: resolved placenta previa, prior pregnancy with vasa previa, velamentous insertion of the cord in the lower uterine segment, placenta succenturiata in the lower uterine segment, and twin gestations. A total of 27,573 patients were referred to our unit for fetal anatomic surveys over the study period. Thirty-one cases of vasa previa were identified, for an incidence of 1.1 per 1000 pregnancies. Twenty-nine cases had full records available for analysis. Five patients (17.2%) had migration and resolution of the vasa previa. When the diagnosis was made during the second trimester (<26 weeks), there was a 23.8% resolution rate (5 of 21); when the diagnosis was made in the third trimester, none resolved (0 of 8 cases). Of the 24 pregnancies (5 twin gestations and 19 singleton gestations) with persistent vasa previa, there was 100% perinatal survival and a median length of gestation of 35 weeks (range, 27 weeks 5 days-36 weeks 5 days). No known missed cases were identified over the study period. The use of standardized screening for vasa previa based on focused criteria was found to be effective in diagnosing vasa previa, with a 100% survival rate. Vasa previa diagnosed during the second trimester resolves in approximately 25% of cases.
Wang, Junyan; Lv, Faqin; Fei, Xiang; Cui, Qiuli; Wang, Longxia; Gao, Xuewen; Yuan, Zhixian; Lin, Qian; Lv, Yali; Liu, Aijun
2011-01-01
Angiogenesis is a critical factor in tumor growth and metastasis, and microvessel density (MVD) was an important parameter for assessing vessels in tumors. However, radiologic assessment of tumor vascularity is not yet well established. In our study, we aimed at investigating the efficacy of contrast-enhanced ultrasonography (CEUS) in exploring the vascularity of the ovarian tumors or tumor-like lesions to assess the relationship between the parameters of the peak intensity (PI) and area under curve (AUC) on CEUS and MVD in ovarian masses. Compared to the contrast-enhanced ultrasound technique, conventional ultrasound shows limitation in differentiating benign and malignant ovarian tumors. The former is promising in improving the sensitivity of detecting small vessels and blood flow in ovarian tumors. Our results showed clear differences in enhancement patterns between benign and malignant ovary tumors or tumor-like lesions. The PI and AUC in the malignant tumors were significantly higher than those in the benign tumors or tumor-like lesions (p=0.001 and =0.01, respectively). The MVD was 43.1 ± 20.4 in the benign tumors or tumor-like lesions and was 65.3 ± 22.3 in the malignant ones (p= 0.01). In both the benign and malignant groups, the PI and AUC were correlated significantly with the MVD (r=0.595, p = 0.001; r =0.533, p = 0.003, respectively). The PI and AUC in CEUS can reflect the MVD in ovarin tumors. The PI and AUC of the ovarian masses in the contrast transvaginal sonography show significant correlation with the angiogenesis and may help in assessing tumor vascularity in ovarian masses. PMID:21614152
Value of ultrasound shear wave elastography in the diagnosis of adenomyosis.
Acar, S; Millar, E; Mitkova, M; Mitkov, V
2016-11-01
The aim of the study was to assess the accuracy of ultrasound shear wave elastography in the diagnosis of adenomyosis. One hundred and fifty three patients were examined. Ninety-seven patients were with suspected adenomyosis and 56 patients were with unremarkable myometrium. Adenomyosis was confirmed in 39 cases (A subgroup) and excluded in 14 cases (B subgroup) in the main group based on morphological examination. All patients underwent ultrasound examination using an Aixplorer (Supersonic Imagine, France) scanner with application of shear wave elastography during transvaginal scanning. Retrospective analysis of the elastography criteria against the findings from morphological/histological examination was performed. The following values of Young's modulus were found in subgroup A (adenomyosis): Emean - 72.7 (22.6-274.2) kPa (median, 5-95th percentiles), Emax - 94.8 (29.3-300.0) kPa, SD - 9.9 (2.6-26.3) kPa; in subgroup B (non adenomyosis) - 28.3 (12.7-59.5) kPa, 33.6 (16.0-80.8) kPa, 3.0 (1.4-15.6) kPa; in the control group - 24.4 (17.9-32.4) kPa, 29.8 (21.6-40.8) kPa, 2.3 (1.3-6.1) kPa, respectively (P < 0.05 for all comparison with subgroup В and the control group). The Emean cut-off value for adenomyosis diagnosis was 34.6 kPa. The sensitivity, specificity, positive predictive value, negative predictive value and area under curve (AUC) were 89.7%, 92.9%, 97.2%, 76.5% and 0.908. The Emax cut-off value was 45.4 kPa (89.7%, 92.9%, 97.2%, 76.5% and 0.907, respectively). This study showed a significant increase of the myometrial stiffness estimated with shear wave elastography use in patients with adenomyosis.
Hao, Yan; Li, Si-Jing; Zheng, Ping; Wu, Xia; Sheng, Jie; Yuan, Dong-Lan; Zhou, Qi; Wei, Wei; Duan, Ai-Hong; Wu, Qing-Qing; Lu, Dan
2018-05-25
To investigate if intraoperative ultrasounds by laparoscopic and transvaginal ultrasonography (LUS and TVS) could improve enucleating the residual fibroids following laparoscopic myomectomy (LM). From March to December 2016, 78 women with uterine fibroids underwent LM, LUS and TVS were applied to detect residual fibroids and to guide surgeons to enucleate them after the visible fibroids were removed during LM operation. The total number of residual fibroids found by LUS was 140, and the total number found by TVS was 127 following LM (P = 0.03). LUS is statistically superior to TVS in the detection of residual fibroids in the anterior wall (P = 0.004), in the detection of intramural fibroids (P = 0.002), and in the detection of fibroids with a diameter ranging from 0.5 to 1 cm (P = 0.002). According to the total number of enucleated fibroids by LM, patients were divided into three groups (Group 1: 2 to 4, Group 2: 5 to 7 and Group 3: ≥8 fibroid counts). The percentages of patients in each group with residual fibroids at the end of surgery were 22.2%, 51.9% and 66.7% respectively. Both LUS and TVS are beneficial to surgical treatment of fibroids by assisting enucleation of residual fibroids following LM, while LUS is more effective in localizing residual fibroids than TVS. Copyright © 2018 Elsevier B.V. All rights reserved.
2016-01-01
Aim of this study was to evaluate the performance of saline hydrosonography (HSGM) (also known as saline infusion sonography (SIS)) against transvaginal ultrasound scan (TVS) and hysteroscopy in the diagnosis of uterine cavity lesions. Diagnostic hysteroscopy with biopsy is considered as the “gold standard” to diagnose intrauterine abnormalities. The introduction of HSGM has improved the diagnostic capability of ultrasound. It is important to establish the efficacy and safety of HSGM before it is widely recommended for use. This retrospective observational data was collected from all 223 patients who underwent TVS, HSGM, and hysteroscopy as part of their gynaecological investigations from 1 January 2008 to 31 December 2010 at Central Middlesex Hospital, London. Endometrial Polyps. TVS: sensitivity 60.53%, specificity 97.06%, positive predictive value (PPV) 95.83%, and negative predictive value (NPV) 68.75% and HSGM: sensitivity 95%, specificity 97.14%, PPV 97.44%, and NPV 94.44%. Submucous Leiomyoma. TVS: sensitivity 57.14%, specificity 93.48%, PPV 84.21%, and NPV 78.18% and HSGM: sensitivity 96.55%, specificity 100.00%, PPV 100.00%, and NPV 97.92%. Diagnostic efficacy of HSGM is superior to TVS for the diagnosis of endometrial polyps and submucous fibroids. HSGM should be considered as an intermediate investigation after TVS to assess intracavity pathology and to confirm the diagnosis; hysteroscopy should become a therapeutic intervention. PMID:27597989
El Behery, Manal M; Saleh, Hend S; Ibrahiem, Moustafa A; Kamal, Ebtesam M; Kassem, Gamal A; Mohamed, Mohamed El Sayed
2015-03-01
To compare the efficacy and safety of the levonorgestrel-releasing intrauterine device (LNG-IUD) with dydrogesterone applied for the same duration in patients having endometrial hyperplasia (EH) without atypia. One hundred thirty eight women aged between 30 and 50 years with abnormal uterine bleeding and diagnosed as EH by transvaginal ultrasound were randomized to receive either LNG-IUD or dydrogesterone for 6 months. Primary outcome measures were regression of hyperplasia after 6 months of therapy. Secondary outcome measures were occurrence of side effects during treatment or recurrence of hyperplasia during follow-up period. After 6 months of treatment, regression of EH occurs in 96% of women in the levonorgestrel-releasing intrauterine system (LNG-IUS) group versus 80% of women in the oral group (P < .001). Adverse effects were relatively common with minimal differences between the 2 groups. Intermenstrual vaginal spotting and amenorrhea were more common in the LNG-IUD group (P value .01 and .0001). Patient satisfaction was significantly higher in the LNG-IUS group (P value .0001). Hysterectomy rates were lower in the LNG-IUS group than in the oral group (P = .001). Recurrence rate was 0% in the LNG-IUD group compared to 12.5% in the oral group. In management of EH without atypia, LNG-IUS achieves a higher regression and a lower hysterectomy rate than oral progesterone and could be used as a first-line therapy. © The Author(s) 2014.
Tian, Yu; Wu, Shuo-Dong; Chen, Ying-Han; Wang, Dan-Bo
2014-01-01
Background Natural orifice transluminal endoscopic surgery (NOTES) involves the introduction of instruments through a natural orifice into the peritoneal cavity to perform surgical interventions. The vagina is the most widely used approach to NOTES. We report the utilization of the vaginal opening at the time of vaginal hysterectomy as a natural orifice for laparoscopic appendectomy. Material/Methods We reviewed cases of 10 patients with chronic appendicitis who underwent transvaginal laparoscopic appendectomy simultaneously with vaginal hysterectomy. A laparoscopic approach was established after removal of the uterus, and the appendix was removed transvaginally. Among the 10 cases, 5 were conducted under gasless laparoscopy by using a simple abdominal wall-lifting instrument. Results All procedures were performed successfully without intraoperative or major postoperative complications. The appendectomy portion of the procedure took approximately 21 minutes to 34 minutes. All patients were discharged less than 4 days after surgery, without external scars. Conclusions Transvaginal appendectomy with rigid laparoscopic instruments following vaginal hysterectomy appears to be a feasible and safe modification of established techniques, with acceptable outcomes. PMID:25300522
Niu, Jun; Song, Wei; Yan, Ming; Fan, Wei; Niu, Weibo; Liu, Enyu; Peng, Cheng; Lin, Pengfei; Li, Peng; Khan, Abdul Qadir
2011-04-01
Transvaginal cholecystectomy has been performed successfully at several research institutions worldwide using natural orifice transluminal endoscopic surgery (NOTES) techniques. However, it is a growing new surgical concept in China. Several technical challenges hinder the safe clinical application of NOTES. This study investigated transvaginal endoscopic cholecystectomy performed with the assistance of a single umbilical trocar and achieved helpful initial clinical experience. From May 2009 to April 2010, a total of 43 transvaginal human cholecystectomies were performed. A single umbilical trocar was used for safe access and laparoscopic assistance during the operation. After the gallbladder had been removed through the vagina, the colpotomy was closed with absorbable stitches under direct vision. In addition, Student's t-test was performed for two samples to estimate the superiority of NOTES over a conventional laparoscopic cholecystectomy (LC) operation. The procedure was successfully completed for all the patients. No intra- or post-operative complications occurred. The patients recovered promptly after surgery, and all were satisfied with ideal cosmetic outcomes. The postoperative pain, hospital stay, and cost of hospitalization with NOTES were much less than with conventional LC operations. Although endoscopic instruments specifically designed for NOTES are not available, the addition of an umbilical trocar is an optimal way to allow safe performance of NOTES procedures in an easily reproducible manner. The authors' initial experience demonstrates that this hybrid technique is potentially feasible and effective for reducing postoperative pain and recovery times while improving the cosmetic results of transvaginal cholecystectomy.
Vaginal prolapse surgery with transvaginal mesh: results of the Austrian registry.
Bjelic-Radisic, V; Aigmueller, T; Preyer, O; Ralph, G; Geiss, I; Müller, G; Riss, P; Klug, P; Konrad, M; Wagner, G; Medl, M; Umek, W; Lozano, P; Tamussino, K; Tammaa, A
2014-08-01
Several mesh repair systems for pelvic organ prolapse (POP) were introduced into clinical practice with limited data on safety, complications or success rates, and impact on sexual function. The Austrian Urogynecology Working Group initiated a registry to assess the use of transvaginal mesh devices for POP repair. We looked at perioperative data, as well as outcomes at 3 and 12 months. Between 2006 and 2010 a total of 20 gynecology departments in Austria participated in the Transvaginal Mesh Registry. Case report forms were completed to gather data on operations, the postoperative course, and results at 3 and 12 months. A total of 726 transvaginal procedures with 10 different transvaginal kits were registered. Intra- and perioperative complications were reported in 6.8%. The most common complication was increased intraoperative bleeding (2.2%). Bladder and bowel perforation occurred in 6 (0.8%) and 2 (0.3%) cases. Mesh exposure was seen in 11% at 3 and in 12% at 12 months. 24 (10%) previously asymptomatic patients developed bowel symptoms by 1 year. De novo bladder symptoms were reported in 39 (10%) at 3 and in 26 (11%) at 12 months. Dyspareunia was reported by 7% and 10% of 265 and 181 sexually active patients at 3 and 12 months postoperatively respectively. The 6.8% rate of intra- and perioperative complications is in line with previous reports. Visceral injury was rare. The 12% rate of mesh exposure is consistent with previous series.
Hybrid NOTES transvaginal cholecystectomy: operative and long-term results after 18 cases.
Pugliese, Raffaele; Forgione, Antonello; Sansonna, Fabio; Ferrari, Giovanni Carlo; Di Lernia, Stefano; Magistro, Carmelo
2010-03-01
Natural orifice transluminal endoscopic surgery (NOTES) is a novel technique that aims at reducing or abolishing skin incisions and potentially also postoperative pain. The purpose of this study was to analyse operative and long-term results of a series of hybrid transvaginal cholecystectomy. Between July 2007 and May 2009, transvaginal NOTES cholecystectomy for symptomatic cholelithiasis was performed by a hybrid technique in 18 women (mean age 54 years), including four women with a body mass index >30 kg/m(2). Dissection was conducted in the first four cases by a round-tip unipolar electrode (UE) introduced through the operative channel of the endoscope coming from the vagina and in the last 14 cases by a ultrasonic scalpel (US) introduced through a 5-mm abdominal port. The short-term outcomes and the long-term results of the two methods were compared. The transvaginal approach entailed no intraoperative complication and no conversion. The overall mean duration of procedures was 75 min (range 40-190). In the first four cases (UE), the operating time was 148 min (range 140-190), whilst in the last 14 (US), it was considerably shorter, 53 min (range 40-60, p < 0.01). We experienced one biliary leak in the UE group, whilst morbidity with US was nil (p < 0.005). The biliary leak healed in 7 days with nasobiliary drainage. No other complications were encountered in either group. The mean follow-up was 12 months (range 1-22), and none of the patients has complained of dyspareunia or other colpotomy-related complications so far. Until specifically designed endoscopic tools are available for NOTES, the hybrid technique with US dissection conducted through a 5-mm port should be preferred in transvaginal cholecystectomy in order to shorten the duration of surgery and make this approach effective, safe and reproducible. After a mean follow-up of 1 year, none of our patients has complained of any problem related to transvaginal approach.
Direct target NOTES: prospective applications for next generation robotic platforms.
Atallah, S; Hodges, A; Larach, S W
2018-05-01
A new era in surgical robotics has centered on alternative access to anatomic targets and next generation designs include flexible, single-port systems which follow circuitous rather than straight pathways. Such systems maintain a small footprint and could be utilized for specialized operations based on direct organ target natural orifice transluminal endoscopic surgery (NOTES), of which transanal total mesorectal excision (taTME) is an important derivative. During two sessions, four direct target NOTES operations were conducted on a cadaveric model using a flexible robotic system to demonstrate proof-of-concept of the application of a next generation robotic system to specific types of NOTES operations, all of which required removal of a direct target organ through natural orifice access. These four operations were (a) robotic taTME, (b) robotic transvaginal hysterectomy in conjunction with (c) robotic transvaginal salpingo-oophorectomy, and in an ex vivo model, (d) trans-cecal appendectomy. Feasibility was demonstrated in all cases using the Flex ® Robotic System with Colorectal Drive. During taTME, the platform excursion was 17 cm along a non-linear path; operative time was 57 min for the transanal portion of the dissection. Robotic transvaginal hysterectomy was successfully completed in 78 min with transvaginal extraction of the uterus, although laparoscopic assistance was required. Robotic transvaginal unilateral salpingo-oophorectomy with transvaginal extraction of the ovary and fallopian tube was performed without laparoscopic assistance in 13.5 min. In an ex vivo model, a robotic trans-cecal appendectomy was also successfully performed for the purpose of demonstrating proof-of-concept only; this was completed in 24 min. A flexible robotic system has the potential to access anatomy along circuitous paths, making it a suitable platform for direct target NOTES. The conceptual operations posed could be considered suitable for next generation robotics once the technology is optimized, and after further preclinical validation.
Laparoscopic ovarian drilling for clomiphene-resistant polycystic ovary syndrome.
Flyckt, Rebecca L; Goldberg, Jeffrey M
2011-03-01
Laparoscopic ovarian drilling (LOD) is an alternative to ovulation induction with gonadotropins for polycystic ovarian syndrome (PCOS) patients unresponsive to clomiphene. It is quick and easy to perform, although the number of punctures and energy doses has not been standardized. The mechanism of LOD is unclear, but it is likely mediated by a reduction in intraovarian androgen production. Serum luteinizing hormone and testosterone levels are rapidly normalized, and these changes are sustained over long-term follow-up. Studies have shown that ovulation and pregnancy rates are comparable between ovulation induction with gonadotropins and LOD, but LOD avoids the risks of multiple pregnancy and ovarian hyperstimulation syndrome. LOD is also more cost effective and better tolerated than gonadotropin therapy. Concerns regarding clinically significant adhesion formation and premature ovarian failure are not supported by the available data. Transvaginal hydrolaparoscopy and ultrasound guidance are less invasive techniques for performing ovarian drilling and may encourage LOD earlier in the course of treatment for PCOS. © Thieme Medical Publishers.
Urethra actively opens from the very beginning of micturition: a new concept of urethral function.
Watanabe, Hiroki; Takahashi, Satoru; Ukimura, Osamu
2014-02-01
Transvaginal or transrectal ultrasound was carried out in an adult female and a male volunteer during micturition. Although the male urethra was enclosed by the prostate, its construction and the function were almost identical to the female urethra. The anterior fibromuscular stroma was not a part of the prostate, but was a part of the urethral muscle. The urethra was surrounded by a thick single muscle unit, developed only on the anterior and lateral sides of the urethra. When the participant wished to urinate, the initial motion was not a bladder contraction, but an active opening of the urethral lumen by the muscle unit. The same unit closed the urethra when continence was kept. In conclusion, the main function of the urethra is thought to be not a closure, but an opening to control the entire micturition process, rather than the bladder being primarily responsible for the control of micturition. © 2013 The Japanese Urological Association.
Adenomyosis and Abnormal Uterine Bleeding (AUB-A)-Pathogenesis, diagnosis, and management.
Abbott, Jason A
2017-04-01
The complex pathogenesis and variable presentation of adenomyosis make it one of the most difficult of the FIGO PALM-COIEN abnormal uterine bleeding group to diagnose and treat. Basic clinical parameters such as prevalence are difficult to accurately assess because histological confirmation is usually employed; however, because of the access to and accuracy and utilization of transvaginal ultrasound and other advanced imaging techniques such as MRI, noninvasive diagnosis is recognized to be highly accurate. The clinical symptoms of pain, abnormal uterine bleeding, and subfertility are the primary presentations of adenomyosis with increasing data supporting a substantial role of this disease in reducing fecundity and interfering with assisted reproductive interventions. Treatments have been aimed at managing symptoms and improving fertility options. Management by hysterectomy is not always desired by women, and with many women having children in their fourth and even fifth decades, it is often not reasonable to consider this radical option. Copyright © 2016. Published by Elsevier Ltd.
Miyata, H; Tsuji, N; Jimi, T; Butsuhara, Y; Terakawa, K; Nagano, T
2014-01-01
Adenosarcoma of the uterine body is a rare mixed tumor in which a benign epithelial component is mixed with a malignant stromal element. It has been considered that this tumor originates from the endometrium and its most common finding of imaging is a polypoid tumor occupying the uterine cavity. The authors herein present a case of 37-year-old female with a complaint of abnormal vaginal bleeding. At the first visit, transvaginal ultrasound and magnetic resonance imaging (MRI) showed a round mass with a diameter of one cm in the uterine wall. No malignant pathological finding was detected. The patient visited the authors again one year later, because of continuous bleeding. At that time, they found a polypoid tumor in the uterine cavity, which turned out to be adenosarcoma with sarcomatous overgrowth. The round mass in the uterus detected at first time seems to have been incipience of adenosarcoma. Prodromal sign of adenosarcoma has not been reported previously.
Nardo, Luciano G; Christodoulou, Dimitra; Gould, Della; Roberts, Steve A; Fitzgerald, Cheryl T; Laing, Ian
2007-01-01
The aims of this prospective study were to investigate the relationship between anti-Müllerian hormone (AMH) and antral follicle count (AFC), and to determine whether these markers of ovarian reserve correlate with lifestyle factors, ethnicity, chronological age and reproductive history. Participants were 136 normo-ovulatory women undergoing infertility work-up within 3 months of their first ovarian stimulation cycle for in vitro fertilization. On day 3 of a spontaneous menstrual cycle, a blood sample for measurement of plasma AMH levels was taken and a transvaginal ultrasound scan to determine the AFC (follicles measuring 2-5 mm in diameter) was performed. Information about smoking, body mass index, alcohol consumption, ethnic origin, chronological age, age at menarche, years since menarche and gravidity were recorded using a case report form. The main outcome measures were plasma AMH concentrations and total number of small antral follicles (AFC). Median plasma levels of AMH were 2.0 ng/ml (interquartile range 1.1-3.6) and AFC was 10 (interquartile range 7-15). A positive correlation between AMH and AFC (r = 0.54, p < 0.0001) was found. AMH and AFC correlated negatively with age (r = -0.30, p < 0.001 and r = -0.27, p = 0.001 respectively) and number of years since menarche (r = -0.23, p = 0.007 and r = -0.21, p = 0.015 respectively), but not with any of the other measures. Circulating AMH levels and AFC correlated with each other and declined significantly with age. There were only weak, non-significant, correlations with lifestyle factors and reproductive history. These putative markers could be used individually or together to assess the age-related decline of ovarian function in normo-ovulatory candidates for IVF.
Pateman, K; Holland, T K; Knez, J; Derdelis, G; Cutner, A; Saridogan, E; Jurkovic, D
2015-12-01
Is there any benefit to including the routine examination by ultrasound of the bladder, ureters and kidneys of women with endometriosis? The benefit of examination of the complete urinary tract of women with suspected endometriosis is that ureteric endometriosis, with or without hydronephrosis, can be detected which facilitates early intervention to prevent nephropathy. Women with endometriosis can get ureteric obstruction but there is no clear consensus on the correct diagnostic technique. Ultrasound is accurate at detecting women with bladder endometriosis but ureteric involvement has not been assessed previously. This was a prospective observational study, conducted at a teaching hospital over a period of 14 months. A total of 848 women presenting with chronic pelvic pain were included into the study. All women with chronic pelvic pain underwent a detailed transvaginal and transabdominal pelvic ultrasound examination to investigate possible causes of their symptoms. This included a systematic assessment of the urinary bladder, pelvic sections of the ureters and kidneys. The ultrasound findings were compared with findings at surgery and the results of targeted urological imaging and interventions. A total of 848 women presenting with chronic pelvic pain were included into the study. 28/848 women (3.3% 95% CI 2.1-4.5) had evidence of urinary tract abnormalities on initial ultrasound scan. Among these 17/848 (2.0% 95% CI 1.06-2.94) had evidence of urinary tract endometriosis, whilst 11/848 (1.3% 95% CI 0.54-2.06) women had other urinary tract abnormalities. Among women with urinary tract endometriosis 11/17 (65%) had evidence of ureteric involvement, 3/17 (18%) had both ureteric and bladder disease and 3/17 (18%) had bladder disease only. 12/17 (59%) women with urinary tract endometriosis also had evidence of hydronephrosis. The diagnosis of ureteral endometriosis had a sensitivity of 12/13 (92%) (95% CI 63.9-99.8), specificity 151/151 100% (95% CI 97.6-100), PPV 100% (95% CI 73.5-100), NPV 99.3% (95% CI 96.3-99.9%) LR- 0.08 (95% CI 0.01-0.39). The routine examination of the complete urinary tract including the distal ureters is a novel technique that should be evaluated in different populations. Ultrasound is an accurate test to diagnose urinary tract involvement in women with suspected pelvic endometriosis and examination of the complete urinary tract should become an integral part of ultrasound assessment of women with suspected endometriosis. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Hysteroscopic outpatient metroplasty to expand dysmorphic uteri (HOME-DU technique): a pilot study.
Di Spiezio Sardo, A; Florio, P; Nazzaro, G; Spinelli, M; Paladini, D; Di Carlo, C; Nappi, C
2015-02-01
The new classification system of uterine anomalies from the European Society of Human Reproduction and Embryology and the European Society for Gynaecological Endoscopy defines T-shaped and tubular-shaped infantilis uteri as 'dysmorphic'. Such malformations have been proven to be associated with poor reproductive performance. A prospective observational study was conducted with 30 infertile women with dysmorphic uterus who underwent the novel Hysteroscopic Outpatient Metroplasty to Expand Dysmorphic Uteri (HOME-DU ) technique. Incisions are made on the uterine walls with a 5 Fr bipolar electrode. The procedure was conducted in outpatients under conscious sedation, using a 5-mm office hysteroscope. The technique was successful in all cases without complications. A net increase of uterine volume was found, as measured at hysteroscopy and three-dimensional transvaginal ultrasound (P < 0.001). Uterine morphology improved in all patients but one. At mean follow-up of 15 months, clinical pregnancy rate was 57% and term delivery rate 65%. These early data support HOME-DU as safe and effective in expanding the volume and normalizing the appearance of the uterine cavity of dysmorphic uteri. Although the cohort was small, pregnancy and live births outcomes were favourable in this poor-prognosis group, implying desirable benefits, which should be compared with other techniques. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Archer, David F; Kovalevsky, George; Ballagh, Susan A; Grubb, Gary S
2009-09-01
A continuous regimen of oral levonorgestrel (LNG) 90 mcg/ethinyl estradiol (EE) 20 mcg was evaluated for inhibition of ovulation, time to return to ovulation after stopping treatment and safety. This open-label study was conducted in healthy women aged 18-35 years. Ovulation was documented before treatment, and then participants received oral tablets containing LNG 90 mcg/EE 20 mcg to be taken continuously for three 28-day intervals. Ovarian activity was assessed three times per week during the treatment period with transvaginal ultrasound scans and measurements of serum 17beta-estradiol, progesterone, follicle-stimulating hormone and luteinizing hormone concentrations. Safety assessments included physical examinations, laboratory evaluations and adverse event records. Thirty-seven of the 58 subjects who received treatment met predefined criteria for efficacy analysis. No on-treatment ovulations occurred in the efficacy or intent-to-treat population. There was evidence of ovulation within 37 days of stopping treatment for 46 (98%) of 47 subjects evaluated posttreatment. The final subject with a history of polycystic ovarian syndrome ovulated by Day 66. The safety profile observed during this 84-day continuous regimen was similar to that seen with other low-dose oral contraceptives administered in a cyclic regimen. The continuous LNG/EE regimen completely inhibited ovulation, with little evidence of follicular development and with rapid return of ovulatory capacity after stopping treatment.
Wang, Erica T; Kao, Chia-Ning; Shinkai, Kanade; Pasch, Lauri; Cedars, Marcelle I; Huddleston, Heather G
2013-07-01
To determine whether manifestations of polycystic ovary syndrome (PCOS), particularly androgen excess, differ between Caucasian and Asian women in the San Francisco Bay Area. Cross-sectional study. Multidisciplinary PCOS clinic at a tertiary academic center. 121 Caucasian and 28 Asian women, aged 18-44, examined between 2006 and 2011 with PCOS verified by a reproductive endocrinologist and dermatologist according to the Rotterdam criteria. Transvaginal ultrasounds, comprehensive dermatologic exams, and serum testing. Hirsutism defined as a modified Ferriman-Gallwey (mFG) score ≥ 8, acne, androgenic alopecia, and biochemical hyperandrogenism. Caucasian and Asian women had a similar prevalence of all measures of androgen excess. Both groups had similar total mFG scores and site-specific mFG scores, except Asian women had a lower site-specific mFG score for the chest. Although Asian women were more likely to use laser hair removal, the results were unchanged when the women with a history of laser hair removal were excluded. Caucasian and Asian women with PCOS living in the same geographic region had a similar prevalence of hirsutism as well as other markers for androgen excess. Further studies are necessary to evaluate the need for ethnic-specific mFG scores in women with PCOS. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Prediction of preterm birth in twin gestations using biophysical and biochemical tests
Conde-Agudelo, Agustin; Romero, Roberto
2018-01-01
The objective of this study was to determine the performance of biophysical and biochemical tests for the prediction of preterm birth in both asymptomatic and symptomatic women with twin gestations. We identified a total of 19 tests proposed to predict preterm birth, mainly in asymptomatic women. In these women, a single measurement of cervical length with transvaginal ultrasound before 25 weeks of gestation appears to be a good test to predict preterm birth. Its clinical potential is enhanced by the evidence that vaginal progesterone administration in asymptomatic women with twin gestations and a short cervix reduces neonatal morbidity and mortality associated with spontaneous preterm delivery. Other tests proposed for the early identification of asymptomatic women at increased risk of preterm birth showed minimal to moderate predictive accuracy. None of the tests evaluated in this review meet the criteria to be considered clinically useful to predict preterm birth among patients with an episode of preterm labor. However, a negative cervicovaginal fetal fibronectin test could be useful in identifying women who are not at risk for delivering within the next week, which could avoid unnecessary hospitalization and treatment. This review underscores the need to develop accurate tests for predicting preterm birth in twin gestations. Moreover, the use of interventions in these patients based on test results should be associated with the improvement of perinatal outcomes. PMID:25072736
Prediction of preterm birth in twin gestations using biophysical and biochemical tests.
Conde-Agudelo, Agustin; Romero, Roberto
2014-12-01
The objective of this study was to determine the performance of biophysical and biochemical tests for the prediction of preterm birth in both asymptomatic and symptomatic women with twin gestations. We identified a total of 19 tests proposed to predict preterm birth, mainly in asymptomatic women. In these women, a single measurement of cervical length with transvaginal ultrasound before 25 weeks of gestation appears to be a good test to predict preterm birth. Its clinical potential is enhanced by the evidence that vaginal progesterone administration in asymptomatic women with twin gestations and a short cervix reduces neonatal morbidity and mortality associated with spontaneous preterm delivery. Other tests proposed for the early identification of asymptomatic women at increased risk of preterm birth showed minimal to moderate predictive accuracy. None of the tests evaluated in this review meet the criteria to be considered clinically useful to predict preterm birth among patients with an episode of preterm labor. However, a negative cervicovaginal fetal fibronectin test could be useful in identifying women who are not at risk for delivering within the next week, which could avoid unnecessary hospitalization and treatment. This review underscores the need to develop accurate tests for predicting preterm birth in twin gestations. Moreover, the use of interventions in these patients based on test results should be associated with the improvement of perinatal outcomes. Copyright © 2014. Published by Elsevier Inc.
Welt, C K; Arason, G; Gudmundsson, J A; Adams, J; Palsdóttir, H; Gudlaugsdóttir, G; Ingadóttir, G; Crowley, W F
2006-11-01
The phenotype of women with polycystic ovary syndrome (PCOS) is variable, depending on the ethnic background. The phenotypes of women with PCOS in Iceland and Boston were compared. The study was observational with a parallel design. Subjects were studied in an outpatient setting. Women, aged 18-45 yr, with PCOS defined by hyperandrogenism and fewer than nine menses per year, were examined in Iceland (n = 105) and Boston (n = 262). PCOS subjects underwent a physical exam, fasting blood samples for androgens, gonadotropins, metabolic parameters, and a transvaginal ultrasound. The phenotype of women with PCOS was compared between Caucasian women in Iceland and Boston and among Caucasian, African-American, Hispanic, and Asian women in Boston. Androstenedione (4.0 +/- 1.3 vs. 3.5 +/- 1.2 ng/ml; P < 0.01) was higher and testosterone (54.0 +/- 25.7 vs. 66.2 +/- 35.6 ng/dl; P < 0.01), LH (23.1 +/- 15.8 vs. 27.6 +/- 16.2 IU/liter; P < 0.05), and Ferriman Gallwey score were lower (7.1 +/- 6.0 vs. 15.4 +/- 8.5; P < 0.001) in Caucasian Icelandic compared with Boston women with PCOS. There were no differences in fasting blood glucose, insulin, or homeostasis model assessment in body mass index-matched Caucasian subjects from Iceland or Boston or in different ethnic groups in Boston. Polycystic ovary morphology was demonstrated in 93-100% of women with PCOS in all ethnic groups. The data demonstrate differences in the reproductive features of PCOS without differences in glucose and insulin in body mass index-matched populations. These studies also suggest that measuring androstenedione is important for the documentation of hyperandrogenism in Icelandic women. Finally, polycystic ovary morphology by ultrasound is an almost universal finding in women with PCOS as defined by hyperandrogenism and irregular menses.
Tsikouras, Panagiotis; Anastasopoulos, George; Maroulis, Vasileios; Bothou, Anastasia; Chalkidou, Anna; Deuteraiou, Dorelia; Anthoulaki, Xanthoula; Bourazan, Arzou Halil; Iatrakis, George; Zervoudis, Stefanos; Galazios, Georgios; Inagamova, Lola-Katerina; Csorba, Roland; Teichmann, Alexander-Tobias
2018-01-01
Objective: Preterm labor is one of the most significant obstetric problems associated with high rate of actual and long-term perinatal complications. Despite the creation of scoring systems, uterine activity monitoring, cervical ultrasound and several biochemical markers, the prediction and prevention of preterm labor is still a matter of concern. The aim of this study was to examine cervical findings for the prediction and the comparative use of Arabin pessary or cerclage for the prevention of preterm birth in asymptomatic women with high risk factors for preterm labor. Material and methods: The study group was composed of singleton pregnancies (spontaneously conceived) with high risk factors for preterm labor. Cervical length, dilatation of the internal cervical os and funneling, were estimated with transvaginal ultrasound during the first and the second trimesters of pregnancy. Results: Cervical funneling, during the second trimester of pregnancy, was the most significant factor for the prediction of preterm labor. The use of Arabin cervical pessary was found to be more effective than cerclage in the prolongation of pregnancy. Conclusion: In women at risk for preterm labor, the detection of cervical funneling in the second trimester of pregnancy may help to predict preterm labor and to apply the appropriate treatment for its prevention. Although the use of cervical pessary was found to be more effective than cerclage, more studies are needed to classify the effectiveness of different methods for such prevention. PMID:29670041
Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D
2014-08-12
To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917-0.942), 0.918 (0.905-0.930), 0.914 (0.886-0.936) and 0.875 (0.853-0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90-96%, specificity 74-79% and diagnostic odds ratio (DOR) 32.8-50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6-75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference.
Robinson, Dudley; Oelke, Matthias; Khullar, Vik; Wijkstra, Hessel; Tretter, Reiner; Stow, Bridget; Compion, Gerhard; Tubaro, Andrea
2016-09-01
Measurement of bladder wall thickness (BWT) by transvaginal ultrasound (TVUS) may be a less invasive method to diagnose overactive bladder (OAB) or detrusor overactivity (DO) and monitor response to therapy. This study assessed whether treatment with solifenacin affects BWT. This was a double-blind, randomised, placebo-controlled, phase 4 study. Adult women with OAB symptoms received solifenacin 5 or 10 mg or placebo once daily for 12 weeks. The co-primary endpoints were change from baseline to Week 12 in TVUS-measured BWT and urinary nerve growth factor. Only results for BWT are presented here. Overall, 547 patients were randomised, 501 patients had a baseline BWT measurement, and change from baseline could be calculated for 478 patients. Mean BWT at baseline was 5.08 mm (range 2.2-11.1, SD = 1.14) and was normally distributed. A significant reduction in BWT from baseline to 12 weeks versus placebo was observed with solifenacin 5 mg (-0.42 vs. -0.16 mm, P = 0.03), but not with the 10 mg dose or with pooled solifenacin, considered the primary comparison. Both solifenacin doses were associated with improvements in efficacy and patient satisfaction endpoints versus placebo. Solifenacin was well tolerated, with dry mouth being the most common adverse event. There was no consistent effect of solifenacin on BWT in women with OAB/DO, despite improvements in efficacy endpoints. This study suggests that routine clinical assessment of BWT with TVUS for monitoring the effects of OAB/DO treatment is not clinically useful. Neurourol. Urodynam. 35:819-825, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Felix, Ashley S.; Weissfeld, Joel L.; Pfeiffer, Ruth M.; Modugno, Francesmary; Black, Amanda; Hill, Lyndon M.; Martin, Jerry; Sit, Anita S.; Sherman, Mark E.; Brinton, Louise A.
2013-01-01
Postmenopausal women with higher circulating estrogen levels are at increased risk of developing breast and endometrial carcinomas. In the endometrium, excess estrogen relative to progesterone produces a net proliferative stimulus, which may result in endometrial thickening. Therefore, we tested the hypothesis that endometrial thickness is a biological marker of excess estrogen stimulation that is associated with risk of breast and endometrial carcinomas. Endometrial thickness was measured in 1,272 postmenopausal women, aged 55–74, who underwent transvaginal ultrasound (TVU) screening as part of the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Trial. Serial endometrial thickness measurements were available for a subset of women at one (n=1,018), two (n=869) and three years (n=641) after baseline. We evaluated associations between endometrial thickness and breast (n=91) and endometrial (n=14) carcinoma by estimating relative risks (RRs) and 95% confidence intervals (CIs) using Cox proportional hazards regression with age as the time metric. Models incorporating baseline endometrial thickness and as a time-varying covariate using all measurements were examined. Median follow-up among study participants was 12.5 years (range: 0.3–13.8 years). Compared to baseline endometrial thickness of 1.0 – 2.99 mm, women with baseline endometrial thickness greater than or equal to 5.0 mm had an increased risk of breast (RR: 2.00, 95% CI 1.15, 3.48) and endometrial (RR: 5.02, 95% CI 0.96, 26.36) carcinomas in models adjusted for menopausal hormone use and BMI. Our data suggest that increased endometrial thickness as assessed by TVU was associated with increased risk of breast and endometrial carcinomas. PMID:23907658
Nylander, Malin; Frøssing, Signe; Bjerre, Anne H; Chabanova, Elizaveta; Clausen, Helle V; Faber, Jens; Skouby, Sven O
2017-08-01
Background Due to improved ultrasound scanners, new three-dimensional (3D) modalities, and novel Anti-Müllerian hormone (AMH)-assays, the ultrasound criteria for polycystic ovarian morphology are under debate and the appropriate thresholds are often requested. Purpose To quantify the differences in estimates of ovarian volume and antral follicle count (AFC) from two-dimensional (2D) and 3D transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI). Material and Methods A cross-sectional study on 66 overweight women with polycystic ovary syndrome (PCOS) according to Rotterdam criteria. Ovarian volume and AFC were estimated from MRI, 2D TVUS, and 3D TVUS, and serum AMH levels were assessed. Bland-Altman statistics were used for comparison. Results Participants had a median age of 29 years (age range, 19-44 years) with a mean BMI of 32.7 kg/m 2 (SD 4.5). Ovarian volume from 2D TVUS was 1.48 mL (95% confidence interval [CI], 0.94-2.03; P < 0.001) and 1.25 mL (95% CI, 0.62-1.87; P < 0.001) smaller than from 3D TVUS and MRI, respectively. AFC from 2D TVUS was 18% (95% CI, 13-23; P < 0.005) and 16% (95% CI, 6-25; P < 0.005) smaller than estimates from 3D TVUS and MRI, respectively. Correlations between AMH and AFC from 2D TVUS, 3D TVUS, and MRI were 0.67, 0.78, and 0.70, respectively ( P < 0.001 for all). Conclusion In an overweight PCOS population, 2D TVUS underestimated ovarian volume and AFC as compared with 3D TVUS and MRI. Serum AMH correlated best with AFC from 3D TVUS, followed by MRI and 2D TVUS. The advantage of 3D TVUS might be of minor clinical importance when diagnosing PCOS, but useful when the actual AFC are of interest, e.g. in fertility counseling and research.
Lin, Min; Xu, XiaoWen; Wang, Yi; Hu, Yue; Zhao, Yu
2014-01-01
To evaluate the use of a levonorgestrel-releasing intrauterine system (LNG-IUS) for treating endometrial hyperplasia in patients with polycystic ovary syndrome (PCOS). LNG-IUSs were inserted in 60 PCOS patients with simple (40 cases), irregular (12 cases), or complex (8 cases) endometrial hyperplasia. Follow-ups were performed at 3, 6, 12, and 24 months after insertion. At each time point, changes in menstruation, hemoglobin level, and endometrial thickness and pathology were recorded. Menstrual changes were assessed with the Pictorial Blood Assessment Chart. Hemoglobin levels were measured by the Blood Routine Test. Endometrial thickness was determined by transvaginal ultrasound. Endometrial pathology was defined as simple, irregular, or complex endometrial hyperplasia by a pathologist after curettage. Outcomes at each time point were compared to baseline (pre-insertion) measurements by Student's t test or ANOVA (for multiple comparisons) with the post hoc Dunnett's test. Differences with a p < 0.05 were considered statistically significant. At all time points after LNG-IUS insertion and in all patients, menstrual blood loss was decreased and hemoglobin level was increased significantly compared to pre-insertion levels. The endometrial thickness was significantly reduced in all groups after 12 months. Most patients showed transformation of the endometrial pathology, with complete disappearance of simple and irregular cases of endometrial hyperplasia and a decreased number of complex endometrial hyperplasia cases. LNG-IUS is an effective, safe, nonsurgical, and atraumatic approach with few side effects for the treatment of endometrial hyperplasia in patients with PCOS. © 2014 S. Karger AG, Basel.
Izhar, Rubina; Husain, Samia; Tahir, Suhaima; Husain, Sonia
2017-01-01
The purpose of this study was to evaluate the ability of poor ovarian response criteria to classify women presenting with infertility and oligomenorrhea as having "occult" premature ovarian insufficiency. This was a cross sectional study conducted at Aziz Medical Center, Karachi, Pakistan from 1st August 2015 to 31st July 2016. Women with infertility and oligomenorrhea were included. All eligible women underwent day 2 FSH level and an early follicular phase transvaginal ultrasound to assess the antral follicular count (AFC). All women then underwent the confirmatory test, of Anti-Mullerian Hormone (AMH) level. The main outcome measure was assignment to occult premature ovarian insufficiency (POI) after screening that used the criteria set out in fertility guideline for predicting the likely ovarian response to gonadotrophin stimulation. Another measure was to compare the sensitivity and specificity of the two index criteria, of FSH and AFC, relative to the emerging reference standard, of the AMH criterion. The three criteria together classified 59 (34.91%) women as occult POI in those with oligomenorrhea. The sensitivity, specificity, negative predictive value and positive predictive value of FSH relative to AMH for these women were 77.8%, 95.7%, 90.2% and 89.4%, respectively whereas the same values of AFC relative to AMH were 92.6%, 99.1 %, 96.6% and 98%, respectively. Women with menstrual irregularity and infertility are at a higher risk for satisfying criteria of poor ovarian response irrespective of age. A policy incorporating these surrogate markers can be used to screen these women for occult premature ovarian insufficiency.
Clemons, Jeffrey L; Weinstein, Milena; Guess, Marsha K; Alperin, Marianna; Moalli, Pamela; Gregory, William Thomas; Lukacz, Emily S; Sung, Vivian W; Chen, Bertha H; Bradley, Catherine S
2013-01-01
To describe the frequency of use and recent change in use of synthetic mesh and biologic grafts in pelvic organ prolapse (POP) and stress urinary incontinence surgery by American Urogynecology Society (AUGS) members. An electronic survey of AUGS members was conducted between December 2011 and January 2012. Frequency of graft use in POP (overall and by transvaginal and transabdominal approaches) and stress urinary incontinence surgery was queried relative to the timing of the 2011 Food and Drug Administration (FDA) safety update. Rates of materials' use before and after the statement were compared using Wilcoxon signed rank test. Fifty-three percent (507/962) of AUGS members responded and were included in analysis; 79% were urogynecologists. Before the FDA warning, in POP surgery, most (90%) used synthetic mesh and fewer (34%) used biologic grafts; 99% used synthetic mesh slings. After the FDA statement, respondents reported an overall decrease in the percent of POP cases in which they used synthetic mesh (P < 0.001) but no change in biologic graft use for POP (P = 0.37) or synthetic mesh sling use (P = 0.10). Specifically, transvaginal mesh use decreased: 40% reported decreased use and 12% stopped use. However, transvaginal mesh was still used by 61% of respondents in at least some cases. No change (62%) or increased use (12%) of mesh was reported for transabdominal POP procedures. Synthetic mesh use in transvaginal POP surgery decreased after the 2011 FDA safety update, but synthetic mesh use for transabdominal POP repair and sling procedures and overall biologic graft use in POP surgery did not decrease.
Challenging the Myth: Transvaginal Mesh is Not Associated with Carcinogenesis.
Chughtai, Bilal; Sedrakyan, Art; Mao, Jialin; Thomas, Dominique; Eilber, Karyn S; Clemens, J Quentin; Anger, Jennifer T
2017-10-01
We sought to determine if there was a potential link between synthetic polypropylene mesh implantation for transvaginal pelvic organ prolapse and stress urinary incontinence, and carcinogenesis using statewide administrative data. Women who underwent transvaginal surgery for pelvic organ prolapse or stress urinary incontinence with mesh between January 2008 and December 2009 in New York State were identified using ICD-9-CM procedure codes and CPT-4 codes. Patients in the mesh cohort were individually matched to 2 control cohorts based on comorbidities and procedure date. Carcinogenesis was determined before and after matching at 1, 2 and 3 years, and during the entire followup time. A total of 2,229 patients who underwent mesh based pelvic organ prolapse surgery and 10,401 who underwent sling surgery for stress urinary incontinence between January 2008 and December 2009 were included in the study. Mean followup was 6 years (range 5 to 7). Exact matching between the mesh and control cohorts resulted in 1,870 pairs for pelvic organ prolapse mesh and cholecystectomy (1:2), 1,278 pairs for pelvic organ prolapse mesh and hysterectomy (1:1), 7,986 pairs for sling and cholecystectomy (1:1) and 3,810 pairs for sling and hysterectomy (1:1). Transvaginal mesh implantation was not associated with an increased risk of a cancer diagnosis (pelvic/local cancers or any cancer) at 1 year and during the entire followup of up to 7 years. Transvaginal surgery with implantation of mesh was not associated with the development of malignancy at a mean followup of 6 years. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Stewart, Sherri L.; Rim, Sun Hee; Gelb, Cynthia A.
2012-01-01
Effective early detection strategies for ovarian cancer do not exist. Current screening guidelines recommend against routine screening using CA-125 alone or in combination with transvaginal ultrasonography (TVS). In this study, the authors used the 2008 "DocStyles" survey to measure clinician beliefs about the effectiveness of CA-125 and…
2013-01-01
Introduction Endometrial hyperplasia has a high risk for malignant transformation and relapses; existing mini-invasive treatments may lead to irrevocable endometrium destruction. The aims were to analyze receptor systems in endometrial hyperplasia, to evaluate the capabilities of ultrasonography, sonoelastography for diagnosis and treatment control, and to develop treatment algorithm. Materials and methods We included 313 women (20–45 years), assessed into the following: group 1 (n = 112) with glandular cystic hyperplasia, group 2 (n = 98) endometrial polyps, and group 3 (n = 103) atypical hyperplasia; and 82 controls who have undergone hysteroscopy before in vitro fertilization in tubal origin infertility were also included. Patients underwent clinical examination, transvaginal ultrasound, immunohistochemical study, and hormonal therapy/hysteroresectoscopy. Results In patients with glandular hyperplasia, we registered increase of endometrium estrogen receptors (75.6% in the epithelium and 30.9% in the stroma; in controls, 43.3% and 29.6%, respectively); in polyps, there was a significant estrogen receptor increase in the stroma (48.2% vs 29.6% in controls), and in atypical hyperplasia, progesterone receptors significantly increased in the stroma. Ki-67 increased (40% to 50%) in the epithelium without changes in the stroma. Ultrasound has a sensitivity of 96% and a specificity of 85% for early detection of endometrial pathology and prediction outcome of intervention, and sonoelastography has a sensitivity of 91% and a specificity of 83% for polyp diagnosis. Personalized treatment was effective in 88.8%, relapse was diagnosed in 11.2% after 6 months, and conservative treatment of atypical hyperplasia was effective in 45%: in 25.8%, ablative hysteroresectoscopy was performed, while in 22.6% with comorbidities, hystero/oophorectomies were performed. Conclusions The evaluation of receptor status with ultrasound data in patients with endometrial hyperplasia allows for a clear definition of the treatment policy, avoidance of relapse, treatment optimization, and observation of such patients. PMID:24314145
Value of ultrasound shear wave elastography in the diagnosis of adenomyosis
Millar, E; Mitkova, M; Mitkov, V
2016-01-01
Background The aim of the study was to assess the accuracy of ultrasound shear wave elastography in the diagnosis of adenomyosis. Methods One hundred and fifty three patients were examined. Ninety-seven patients were with suspected adenomyosis and 56 patients were with unremarkable myometrium. Adenomyosis was confirmed in 39 cases (A subgroup) and excluded in 14 cases (B subgroup) in the main group based on morphological examination. All patients underwent ultrasound examination using an Aixplorer (Supersonic Imagine, France) scanner with application of shear wave elastography during transvaginal scanning. Retrospective analysis of the elastography criteria against the findings from morphological/histological examination was performed. Results The following values of Young’s modulus were found in subgroup A (adenomyosis): Emean – 72.7 (22.6–274.2) kPa (median, 5–95th percentiles), Emax – 94.8 (29.3–300.0) kPa, SD – 9.9 (2.6–26.3) kPa; in subgroup B (non adenomyosis) – 28.3 (12.7–59.5) kPa, 33.6 (16.0–80.8) kPa, 3.0 (1.4–15.6) kPa; in the control group – 24.4 (17.9–32.4) kPa, 29.8 (21.6–40.8) kPa, 2.3 (1.3–6.1) kPa, respectively (P < 0.05 for all comparison with subgroup В and the control group). The Emean cut-off value for adenomyosis diagnosis was 34.6 kPa. The sensitivity, specificity, positive predictive value, negative predictive value and area under curve (AUC) were 89.7%, 92.9%, 97.2%, 76.5% and 0.908. The Emax cut-off value was 45.4 kPa (89.7%, 92.9%, 97.2%, 76.5% and 0.907, respectively). Conclusion This study showed a significant increase of the myometrial stiffness estimated with shear wave elastography use in patients with adenomyosis. PMID:27847535
Treatment for Uterine Isthmocele, A Pouchlike Defect at the Site of a Cesarean Section Scar.
Setubal, Antonio; Alves, João; Osório, Filipa; Guerra, Adalgisa; Fernandes, Rodrigo; Albornoz, Jaime; Sidiroupoulou, Zacharoula
2018-01-01
An isthmocele appears as a fluid pouchlike defect in the anterior uterine wall at the site of a prior cesarean section and ranges in prevalence from 19% to 84%, a direct relation to the increase in cesarean sections performed worldwide. Many definitions have been suggested for the dehiscence resulting from cesarean sections, and we propose standardization with a single term for all cases-isthmocele. Patients are not always symptomatic, but symptoms typically include intermittent abnormal bleeding, pain, and infertility. Pregnancy complications that result from an isthmocele include ectopic pregnancy, low implantation, and uterine rupture. Magnetic resonance imaging and transvaginal ultrasound are the gold standard imaging techniques for diagnosis. Surgical treatment of an isthmocele is still a controversial issue but should be offered to symptomatic women or the asymptomatic patient who desires future pregnancy. When surgery is the treatment choice, laparoscopy guided by hysteroscopy, hysteroscopy alone, or vaginal repair are the best options depending on the isthmocele's characteristics and surgeon expertise. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.
Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo
2015-01-01
Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology.
Paris, Ida; Prelaj, Arsela; Onesti, Concetta Elisa; Baldoni, Alessandra; Giovagnoli, Maria Rosaria; Bassanelli, Maria; Lauro, Salvatore; Marchetti, Paolo
2014-01-01
The occurrence of radiological mediastinal lymphadenopathy as the only evidence of tumor recurrence of cervical carcinoma is very rare. We report on such a case with stenosis of the esophagus. A 36-year-old Caucasian woman, without any relevant history of gynecological cancer, underwent a trans-vaginal ultrasound with evidence of any cervical lesion locally extended. After histologically-proven diagnosis of squamous cell carcinoma of the cervix uterine, the patient was treated by neoadjuvant chemoradiation, followed by total abdominal hysterectomy with bilateral salpingoophorectomy. A subsequent close follow-up was negative for recurrence of disease until December 2008, two years after diagnosis. At that period, the patient experienced cough and severe dysphagia and for this reason she underwent several examinations including esophagogastroduodenoscopy, whole-body computed tomographic scan and bronchoscopy with transbronchial needle aspiration. Histology led to diagnosis of recurrence of cervical cancer, HPV31-positive, in multiple mediastinal lymphnodes, with infiltration of the esophageal mucosa. Mediastinal lymphade-nopathy in patients with a history of cervical carcinoma should be suspicious of metastatic disease, even if there is no radiological evidence of distant metastases.
Taieb, Joëlle; Mendez Lozano, Daniel H; Benattar, Clarisse; Messaoudi, Chérif; Poüs, Christian
2007-12-01
We assessed a new estradiol (E2) immunoassay on the Architect-i2000 (Abbott Laboratories) for monitoring ovulation stimulation for IVF-ET and re-establishing clinical cut-off points. The method has been modified to improve E2 measurements especially at normal and low concentrations. E2 was determined for 552 samples, from 83 women, presenting normal follicular status and undergoing 100 cycles of IVF treatment. We assessed the value of this assay for down-regulation of E2 concentration limit using gonadoliberin-releasing hormone agonist (GnRHa), and monitoring of the ovarian hyperstimulation, expected range of E2 per mature follicle prior to the administration of exogenous hCG and day 3 concentration limit. We compared results with our routine method (E2-6II Advia-Centaur; Siemens-Diagnostics) for which decision-making values were known. Considering E2 concentrations obtained with the new Architect-i2000 assay for patients treated with GnRHa for 2 weeks, the cutoff-point for ovarian down-regulation should be set down at 110 pmol/L to maintain 100% of sensitivity. Considering day 3 concentration limit determination, results were not significantly different from those obtained with our routine method. The mean E2 values per mature follicle fell into the range generally expected. E2 determination with the new E2 Architect-i2000 assay could be used to monitor ovulation, in patients undergoing IVF-ET, in combination with transvaginal ultrasound.
Gallicchio, Lisa; Miller, Susan R.; Kiefer, Judith; Greene, Teresa; Zacur, Howard A.; Flaws, Jodi A.
2015-01-01
Objective The aim of this study was to examine the associations between demographic characteristics, health behaviors, hormone concentrations, and the experiencing of any, current, more severe, and more frequent midlife hot flashes. Methods Baseline data were analyzed from 732 women aged 45 to 54 years enrolled in the Midlife Women's Health Study. A clinic visit was conducted to collect blood samples for hormone assays and to measure ovarian volume using transvaginal ultrasound. A self-administered questionnaire ascertained information on demographic factors, health habits, and hot flashes history. Multivariable logistic regression was conducted to examine the associations between potential risk factors and the hot flashes outcomes. Results Approximately 45% of participants reported experiencing midlife hot flashes. In the covariate-adjusted models, older age, peri-menopausal status, current and former cigarette smoking, and depressive symptoms were significantly associated with increased odds of all of the hot flashes outcomes. In addition, history of oral contraceptive use was associated with increased odds of any hot flashes. In contrast, higher current alcohol intake was significantly associated with decreased odds of any, current, and more severe hot flashes. Higher estradiol and progesterone concentrations were significantly associated with decreased odds of all hot flashes outcomes. Conclusions Although the temporalities of such associations are not known due to the cross-sectional nature of the data, these observed relationships can help to identify women at risk for hot flashes. PMID:25783472
Pulvirenti, Elia; Toro, Adriana; Di Carlo, Isidoro
2010-01-01
Natural Orifice Transluminal Endoscopic Surgery (NOTES) is an innovative approach in which a flexible endoscope enters the abdominal cavity via the transesophageal, transgastric, transcolonic, transvaginal or transvescical route, combining the technique of minimally invasive surgery with flexible endoscopy. Several groups have described different modifications by using flexible endoscopes with different levels of laparoscopic assistance. Transvaginal cholecystectomy (TVC) consists in accessing the abdominal cavity through a posterior colpotomy and using the vaginal incision as a visual or operative port. An increasing interest has arisen around the TVC; nevertheless, the most common and highlighted concern is about the lack of specific instruments dedicated to the vaginal access route. TVC should be distinguished between "pure", in which the entire operation is performed through the transvaginal route, and "hybrid", in which the colpotomy represents only a support to introduce instruments and the operation is performed mainly by the classic transabdominal-introduced instruments. Although this new technique seems very appealing for patients, on the other hand it is very challenging for the surgeon because of the difficulties related to the mode of access, the limited technology currently available and the risk of complications related to the organ utilized for access. In this brief review all the most recent advancements in the field of TVC's techniques and instrumentations are listed and discussed.
The Predictive Value of Ultrasound Learning Curves Across Simulated and Clinical Settings.
Madsen, Mette E; Nørgaard, Lone N; Tabor, Ann; Konge, Lars; Ringsted, Charlotte; Tolsgaard, Martin G
2017-01-01
The aim of the study was to explore whether learning curves on a virtual-reality (VR) sonographic simulator can be used to predict subsequent learning curves on a physical mannequin and learning curves during clinical training. Twenty midwives completed a simulation-based training program in transvaginal sonography. The training was conducted on a VR simulator as well as on a physical mannequin. A subgroup of 6 participants underwent subsequent clinical training. During each of the 3 steps, the participants' performance was assessed using instruments with established validity evidence, and they advanced to the next level only after attaining predefined levels of performance. The number of repetitions and time needed to achieve predefined performance levels were recorded along with the performance scores in each setting. Finally, the outcomes were correlated across settings. A good correlation was found between time needed to achieve predefined performance levels on the VR simulator and the physical mannequin (Pearson correlation coefficient .78; P < .001). Performance scores on the VR simulator correlated well to the clinical performance scores (Pearson correlation coefficient .81; P = .049). No significant correlations were found between numbers of attempts needed to reach proficiency across the 3 different settings. A post hoc analysis found that the 50% fastest trainees at reaching proficiency during simulation-based training received higher clinical performance scores compared to trainees with scores placing them among the 50% slowest (P = .025). Performances during simulation-based sonography training may predict performance in related tasks and subsequent clinical learning curves. © 2016 by the American Institute of Ultrasound in Medicine.
Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D
2014-01-01
Background: To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. Methods: This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. Results: The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917–0.942), 0.918 (0.905–0.930), 0.914 (0.886–0.936) and 0.875 (0.853–0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90–96%, specificity 74–79% and diagnostic odds ratio (DOR) 32.8–50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6–75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. Conclusions: This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference. PMID:24937676
Bili, Eleni; Bili, Authors Eleni; Dampala, Kaliopi; Iakovou, Ioannis; Tsolakidis, Dimitrios; Giannakou, Anastasia; Tarlatzis, Basil C
2014-08-01
The aim of this study was to determine the performance of prostate specific antigen (PSA) and ultrasound parameters, such as ovarian volume and outline, in the diagnosis of polycystic ovary syndrome (PCOS). This prospective, observational, case-controlled study included 43 women with PCOS, and 40 controls. Between day 3 and 5 of the menstrual cycle, fasting serum samples were collected and transvaginal ultrasound was performed. The diagnostic performance of each parameter [total PSA (tPSA), total-to-free PSA ratio (tPSA:fPSA), ovarian volume, ovarian outline] was estimated by means of receiver operating characteristic (ROC) analysis, along with area under the curve (AUC), threshold, sensitivity, specificity as well as positive (+) and negative (-) likelihood ratios (LRs). Multivariate logistical regression models, using ovarian volume and ovarian outline, were constructed. The tPSA and tPSA:fPSA ratio resulted in AUC of 0.74 and 0.70, respectively, with moderate specificity/sensitivity and insufficient LR+/- values. In the multivariate logistic regression model, the combination of ovarian volume and outline had a sensitivity of 97.7% and a specificity of 97.5% in the diagnosis of PCOS, with +LR and -LR values of 39.1 and 0.02, respectively. In women with PCOS, tPSA and tPSA:fPSA ratio have similar diagnostic performance. The use of a multivariate logistic regression model, incorporating ovarian volume and outline, offers very good diagnostic accuracy in distinguishing women with PCOS patients from controls. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Ivanovski, M; Damcevski, N; Radevska, B; Doicev, G
2012-01-01
To investigate whether success rates of IVF/ICSI could be predicted by using the Color Doppler technique by measuring the uterine artery and arcuate artery pulsatility (PI), resistance (RI), and velocity (Vs) indices on the day of hCG injection. This was a prospective observational study at the St Lazar Hospital, Skopje; 106 patients with an indication for IVF or ICSI according to departmental protocol underwent controlled ovarian hyperstimulation followed by IVF/ICSI and embryo transfer. Using Color Doppler in the two-dimensional (2D) mode, flow velocity waveforms were obtained from the ascending main branch of the uterine artery on the right and left sides of the cervix in a longitudinal plane and arcuate arteries, before they entered the uterus. The PI, RI and peak systolic velocity (PSV) of the uterine arteries and arcuate arteries were calculated electronically when similar consecutive waveforms of good quality were obtained and results were compared between patients who conceived and those who did not. In total, 106 patients, aged 24-42 years were included in the study. The patients were divided into two groups according to successful outcome, defined as pregnancy and failure of implantation, where no pregnancy was detected. A total of 40 pregnancies resulted; a crude pregnancy rate was 40/106 (37.7%). There were no significant differences between either group in patients' age, type and duration of infertility; basal levels of FSH, LH and E2; number of gonadotropin ampoules used for ovulation induction; number of retrieved oocytes and number of transferred embryos. No cycle was canceled after initiation of gonadotropin stimulation. In our results, there were statistically significant lower mean uterine artery PI and RI in the pregnant group than in the non-pregnant group (P < 0.05). Arcuate artery PI value was lower in the pregnant group than in the non-pregnant group, but this did not reach statistical significance. Peak systolic velocity (Vs) values in both the mean uterine artery and arcuate artery were higher in the pregnant group than in the non-pregnant group; however, the difference was not statistically significant. Vascular impedance was calculated with PI, RI, and Vs values, among which PI was found to be the most important. Optimal uterine receptivity can be accomplished by reduced vascular resistance and increased blood flow, which will improve pregnancy success. We suggest the use of transvaginal color Doppler ultrasonography to measure the blood flow in uterine arteries and arcuate arteries before hCG in IVF cycles.
Helmy, Samir; Mavrelos, Dimitrios; Sawyer, Elinor; Ben-Nagi, Jara; Koch, Marianne; Day, Andrea; Jurkovic, Davor
2015-01-01
Objective To establish clearance curves for serum β -hCG in women with successfully expectantly managed tubal ectopic pregnancies. Design Retrospective cohort study. Non- viable tubal ectopic pregnancy was diagnosed on transvaginal ultrasound. If initial serum β hCG was less than 5000 IU/L and patients were asymptomatic, expectant management was offered. Patients underwent serial β hCG measurements until serum β hCG was less than 20 IU/l, or the urine pregnancy test was negative. Setting Early Pregnancy and Gynaecology Assessment Unit, Kings College Hospital, London (December 1998 to July 2006). Patients We included 161 women with diagnosed non-viable tubal ectopic pregnancy who underwent successful expectant management. Main outcome measure Serum β hCG level. Results Mean initial serum β- hCG was 488 IU/L (41 - 4883) and median serum β hCG clearance time was 19 days (5 - 82). The average half-life of β hCG clearance was 82.5 hours (±SD 50.2) in patients with steadily declining serum β- hCG levels compared to 106.7 hours (±SD 72.0) in patients with primarily plateauing β-hCG levels in the declining phase. However, these differences were not significant (p>0.05). Conclusion We identified a median follow-up of 19 days until serum β hCG clearance in women with tubal ectopic pregnancy and successful expectant management. Although non- significant, women with initially plateauing serum β hCG showed a longer follow-up time until clearance compared to women with steadily declining β hCG levels. This information may serve as a guideline enabling clinicians to predict the length of follow-up for women with tubal ectopic pregnancy and expectant management. PMID:26135923
Early pregnancy failure: factors affecting successful medical treatment.
Odeh, Marwan; Tendler, Rene; Kais, Mohamad; Maximovsky, Olga; Ophir, Ella; Bornstein, Jacob
2010-06-01
The results of medical treatment for early pregnancy failure are conflicting. To determine whether gestational sac volume measurement as well as other variables can predict the success rate of medical treatment for early pregnancy failure. The study group comprised 81 women diagnosed with missed abortion or anembryonic pregnancy who consented to medical treatment. Demographic data were collected and beta-human chorionic gonadotropin level was documented. Crown-rump length and the sac volume were measured using transvaginal ultrasound. TVU was performed 12-24 hours after intravaginal administration of 800 micro g misoprostol. If the thickness of the uterine cavity was less than 30 mm, the women were discharged. If the sac was still intact or the thickness of the uterine cavity exceeded 30 mm, they were offered an additional dosage of intravaginal misoprostol or surgical uterine evacuation. Medical treatment successfully terminated 32 pregnancies (39.5%), 30 after one dose of misoprostol and 2 after two doses (group A); 49 underwent surgical evacuation (group B), 47 following one dose of misoprostol and 2 following two doses. There were no significant differences between the groups in age and gestational week. Gestational sac volume did not differ between groups A and B (10.03 and 11.98 ml respectively, P = 0.283). Parity (0.87 and 1.43, P = 0.015), previous pregnancies (2.38 and 2.88, P = 0.037), and betahCG concentration (6961 and 28,748 mlU, P = 0.013) differed significantly between the groups. Gestational sac volume is not a predictor of successful medical treatment for early pregnancy failure. Previous pregnancies and deliveries and higher betahCG concentration negatively affect the success rate of medical treatment.
Multimedia article: Transvaginal laparoscopic cholecystectomy: laparoscopically assisted.
Bessler, Marc; Stevens, Peter D; Milone, Luca; Hogle, Nancy J; Durak, Evren; Fowler, Dennis
2008-07-01
Natural orifice transluminal endoscopic surgery (NOTES) is considered the new frontier for minimally invasive surgery. NOTES procedures such as peritoneoscopy, splenectomy, and cholecystectomy in animal models have been described. The aim of our experiment was to determine the feasibility and technical aspects of a new endoluminal surgical procedure. After approval from Columbia's IACUC, a transvaginal laparoscopically assisted endoscopic cholecystectomy was performed on four 30 kg Yorkshire pigs. The first step was to insert a 1.5 cm endoscope into the vagina under direct laparoscopic vision. Then the gallbladder was reached and, with the help of a laparoscopic grasper to hold up the gallbladder, the operation was performed. At the end of the procedure the gallbladder was snared out through the vagina attached to the endoscope. There were no intraoperative complications such as bleeding, common bile duct or endo-abdominal organ damage. Total operative time ranged between 110 and 155 min. Based on our experience in the porcine model, we believe that a transvaginal endoscopic cholecystectomy is feasible in humans.
Lima, Estevao; Rolanda, Carla; Correia-Pinto, Jorge
2009-05-01
An isolated transgastric port raises serious limitations in performing natural orifice translumenal endoscopic surgery (NOTES) complex procedures in the urology field. In an attempt to overcome these limitations, several solutions has been advanced, such as the hybrid approach (adding a single abdominal port access) or the pure NOTES combined approach (joining multiple natural orifice ports). To review the current state of experimental and clinical results of multiple ports in NOTES, a literature search of PubMed was performed, seeking publications from January 2002 to 2008 on NOTES. In addition, we looked at pertinent abstracts of annual meetings of the American Urological Association, the European Association of Urology, and the World Congress of Endourology from 2007. Multiple ports of entry seem to be necessary, mainly for moderately complex procedures. Thus, we could find studies using the hybrid approach (combination of transgastric or transvaginal access with a single transabdominal port), or using the pure NOTES combined approach (transgastric and transvesical, transvaginal and transcolonic, or transgastric and transvaginal). There is still limited experience in humans using these approaches, and no comparative studies exist to date. It is predictable that for moderately complex procedures, we will need multiple ports, so the transvaginal-transabdominal (hybrid) approach is the most appealing, whereas in a pure NOTES perspective, the transgastric-transvesical approach seems to be the preferred approach. We are waiting for new equipment and instruments that are more appropriate for these novel techniques.
Hybrid natural orifice transluminal endoscopic cholecystectomy: prospective human series.
Cuadrado-Garcia, Angel; Noguera, Jose F; Olea-Martinez, Jose M; Morales, Rafael; Dolz, Carlos; Lozano, Luis; Vicens, Jose-Carlos; Pujol, Juan José
2011-01-01
Natural orifice transluminal endoscopic surgery (NOTES) makes it possible to perform intraperitoneal surgical procedures with a minimal number of access points in the abdominal wall. Currently, it is not possible to perform these interventions without the help of abdominal wall entryways, so these procedures are hybrids fusing minilaparoscopy and transluminal endoscopic surgery. This report presents a prospective clinical series of 25 patients who underwent transvaginal hybrid cholecystectomy for cholelithiasis. The study comprised a clinical series of 25 consecutive nonrandomized women who underwent a fusion transvaginal NOTES and minilaparoscopy procedure with two trocars for cholelithiasis: one 5-mm umbilical trocar and one 3-mm trocar in the upper left quadrant. The study had no control group. The scheduled surgical intervention was performed for all 25 women. No intraoperative complications occurred. One patient had mild hematuria that resolved in less than 12 h, but no other complications occurred during an average follow-up period of 140 days. Of the 25 women, 20 were discharged in 24 h, and 5 were discharged less than 12 h after the procedure. Hybrid transvaginal cholecystectomy, combining NOTES and minilaparoscopy, is a good surgical model for minimally invasive surgery. It can be performed in surgical settings where laparoscopy is practiced regularly using the instruments normally used for endoscopy and laparoscopic surgery. Due to the reproducibility of the intervention and the ease of vaginal closure, hybrid transvaginal cholecystectomy will permit further development of NOTES in the future.
Semi-automatic system for ultrasonic measurement of texture
Thompson, R. Bruce; Wormley, Samuel J.
1991-09-17
A means and method for ultrasonic measurement of texture non-destructively and efficiently. Texture characteristics are derived by transmitting ultrasound energy into the material, measuring the time it takes to be received by ultrasound receiving means, and calculating velocity of the ultrasound energy from the timed measurements. Textured characteristics can then be derived from the velocity calculations. One or more sets of ultrasound transmitters and receivers are utilized to derive velocity measurements in different angular orientations through the material and in different ultrasound modes. An ultrasound transmitter is utilized to direct ultrasound energy to the material and one or more ultrasound receivers are utilized to receive the same. The receivers are at a predetermined fixed distance from the transmitter. A control means is utilized to control transmission of the ultrasound, and a processing means derives timing, calculation of velocity and derivation of texture characteristics.
Semi-automatic system for ultrasonic measurement of texture
Thompson, R.B.; Wormley, S.J.
1991-09-17
A means and method are disclosed for ultrasonic measurement of texture nondestructively and efficiently. Texture characteristics are derived by transmitting ultrasound energy into the material, measuring the time it takes to be received by ultrasound receiving means, and calculating velocity of the ultrasound energy from the timed measurements. Textured characteristics can then be derived from the velocity calculations. One or more sets of ultrasound transmitters and receivers are utilized to derive velocity measurements in different angular orientations through the material and in different ultrasound modes. An ultrasound transmitter is utilized to direct ultrasound energy to the material and one or more ultrasound receivers are utilized to receive the same. The receivers are at a predetermined fixed distance from the transmitter. A control means is utilized to control transmission of the ultrasound, and a processing means derives timing, calculation of velocity and derivation of texture characteristics. 5 figures.
[Value of ultrasonography to predict the endometrial cancer in postmenopausal bleeding].
Bouzid, A; Ayachi, A; Mourali, M
2015-10-01
To build mathematical models for evaluating the individual risk of endometrial malignancy in women with postmenopausal bleeding and a thick endometrium using clinical data, sonographic endometrial thickness and power Doppler ultrasound findings. A total of 117 patients underwent transvaginal two-dimensional gray-scale and power Doppler ultrasound examination of the endometrium before getting endometrial biopsy. Inclusion criteria were post-menopausal bleeding and a thick endometrium greater than 5mm. The ultrasound image showing the most vascularized section through the endometrium as assessed by power Doppler was frozen to estimate endometrial thickness and features. The vascularity index was calculated using computer software. A structured history was taken to collect clinical information. Multivariate logistic regression analysis was used to create mathematical models to predict endometrial malignancy. There were 31 (26.4%) malignant and 86 (74.6%) benign endometria… Women with a malignant endometrium were older (median age 61 vs 56 years, P=0.036) and had a thicker endometrium (median thickness 18.8mm vs 12.5; P=0.002) and higher values for vascularity index. When using only clinical data to build a model for estimating the risk of endometrial malignancy, a model including the variables age had the largest area under the receiver-operating characteristics curve (AUC), with a value of 0.69 (95% confidence interval [CI], 0.59-0.79). A model including age and endometrial thickness had an AUC of 0.72 (95% CI, 0.50-0.96), and one including age, endometrial thickness and vascularity index had an AUC of 0.91 (95% CI, 0.62-0.97). Using a risk cut-off of 12%, the latter model had sensitivity 89%, specificity 74%, positive likelihood ratio 3.42 and negative likelihood ratio 0.14. Postmenopausal bleeding is a frequent cause of consultation in gynecological particularly in peri- or post-menopausal period. They are the main alarm sign of endometrial carcinoma. Vaginal ultrasound has become the "gold standard" in the initial exploration. It is a powerful tool to estimate the individual risk of malignancy in symptomatic postmenopausal women in order to optimize the management. The diagnostic performance of models predicting endometrial cancer increases substantially when sonographic and power Doppler information are added to clinical variables. This model seems to be clinically useful but need to be prospectively validated. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Chaudhury, Kalyansree; Chaudhury, Sudeshna; Chowdhury, Subhankar
2008-10-01
To decide if metformin augments clomiphene response for ovulation induction in non-obese women with polycystic ovary syndrome, a prospective randomised placebo-controlled trial was undertaken among 27 patients, who were found eligible for this study following clinical assessment and basic investigations. Women with polycystic ovary syndrome, even when non-obese, has increased insulin-resistance and do not respond favourably when treated with clomiphene for ovulation induction. The hypothesis is that by improving insulin- resistance and thus reversing from hyperinsulinaemia towards normal insulin secretion will enhance the responsiveness of these women to ovulation inducing effects of clomiphene. In the metformin group there were 15 patients who were given metformin 500mg orally 8 hourly daily for initial 3 months whereas in the placebo group there were 12 patients who were given folic acid (as placebo) 5mg orally once daily for initial 3 months. Thereafter, all the 27 patients in both groups were treated with clomiphene 50mg orally once daily from day 2 for 5 days in each month for subsequent 3 months. However, metformin and folic acid was continued in the metformin group and placebo group respectively for these subsequent 3 months when these patients were being treated with clomiphene for ovulation induction. Ovulation, as the outcome measure, was assessed by serial transvaginal ultrasound scanning from day 8/ day 9 and serum progesterone estimation on the 7th or 8th day following the ultrasound evidence of ovulation. Ovulation is taken to have occurred when serum progesterone was > or =8 ng/ml. Ovulation was noted to have occurred in 71.11% of the 45 cycles studied in 15 patients in the metformin group whereas ovulation occurred in 11.11% of the 36 cycles studied in 12 patients in the placebo group. This difference was highly statistically significant (p < 0.001) by Fisher's exact test. It can be conducted that metformin augments the ovulation inducing effects of clomiphene in non-obese women with polycystic ovary syndrome.
Initial evaluation and referral guidelines for management of pelvic/ovarian masses.
Le, Tien; Giede, Christopher; Salem, Shia; Lefebvre, Guylaine; Rosen, Barry; Bentley, James; Kupets, Rachel; Power, Patti; Renaud, Marie-Claude; Bryson, Peter; Davis, Donald B; Lau, Susie; Lotocki, Robert; Senikas, Vyta; Morin, Lucie; Bly, Stephen; Butt, Kimberly; Cargill, Yvonne M; Denis, Nanette; Gagnon, Robert; Hietala-Coyle, Marja Anne; Lim, Kenneth Ian; Ouellet, Annie; Raciot, Maria-Hélène
2009-07-01
To optimize the management of adnexal masses and to assist primary care physicians and gynaecologists determine which patients presenting with an ovarian mass with a significant risk of malignancy should be considered for gynaecologic oncology referral and management. Laparoscopic evaluation, comprehensive surgical staging for early ovarian cancer, or tumour debulking for advanced stage ovarian cancer. To optimize conservative versus operative management of women with possible ovarian malignancy and to optimize the involvement of gynaecologic oncologists in planning and delivery of treatment. Published literature was retrieved through searches of PubMed or MEDLINE, CINAHL, and the Cochrane Library, using appropriate controlled vocabulary and key words. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified by searching the web sites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. 1. Primary care physicians and gynaecologists should always consider the possibility of an underlying ovarian cancer in patients in any age group who present with an adnexal or ovarian mass. (II-2B) 2. Appropriate workup of a perimenopausal or postmenopausal woman presenting with an adnexal mass should include evaluation of symptoms and signs suggestive of malignancy, such as persistent pelvic/abdominal pain, urinary urgency/frequency, increased abdominal size/bloating, and difficulty eating. In addition, CA125 measurement should be considered. (II-2B) 3. Transvaginal or transabdominal ultrasound examination is recommended as part of the initial workup of a complex adnexal/ovarian mass. (II-2B) 4. Ultrasound reports should be standardized to include size and unilateral/bilateral location of the adnexal mass and its possible origin, thickness of septations, presence of excrescences and internal solid components, vascular flow distribution pattern, and presence or absence of ascites. This information is essential for calculating the risk of malignancy index II score to identify pelvic mass with high malignant potential. (IIIC) 5. Patients deemed to have a high risk of an underlying malignancy should be reviewed in consultation with a gynaecologic oncologist for assessment and optimal surgical management. (II-2B).
Dmochowski, Roger R; Avon, Mark; Ross, James; Cooper, Jay M; Kaplan, Richard; Love, Beverly; Kohli, NeeraJ; Albala, David; Shingleton, Bruce
2003-03-01
We evaluate the safety and efficacy of a new treatment modality for genuine stress urinary incontinence which was a transvaginal radio frequency applicator to deliver radio frequency energy to the endopelvic fascia. The purported mechanism of effect for this therapy is shrinkage of the collagenated tissue which composes the endopelvic fascia that supports the bladder neck and proximal urethra, thus stabilizing the proximal urethra and bladder neck. In prior animal trials and early pilot studies this therapy was shown to cause a reproducible thermal effect manifested by fascial shrinkage. Preliminary human trials indicated a therapeutic benefit of this therapy for women with genuine stress urinary incontinence. To our knowledge this is the first multicenter study of a transvaginal approach for radio frequency of the endopelvic fascia for treatment of genuine stress incontinence. Between June 1999 and June 2000, 120 consecutive women (mean age 49.9 years) at 10 sites underwent transvaginal radio frequency treatment in a prospective trial to evaluate the overall efficacy and safety profile of this therapy. All patients had preoperative urethral hypermobility (average cotton swab change 38 degrees). Detrusor instability was excluded by cystometry. In all procedures precisely controlled radio frequency energy was applied to the endopelvic fascia to heat and shrink the tissue. The patients were evaluated postoperatively at 1 week and at 1, 3, 6 and 12 months using objective and subjective measures. Primary end points consisted of physician assessment of continence, patient reported pad use and the number of patient reported episodes. Safety was determined for acute (immediate postoperative) and chronic time frames. Of the 120 patients 96 completed 1-year evaluation. Average operative time was less than 30 minutes, and all patients were treated as outpatients. Preoperatively 101 patients (84%) averaged 1 or more episodes of urinary incontinence per day. At 3, 6 and 12 months 57%, 66% and 59% of patients, respectively, averaged 1 or no daily episodes of urinary incontinence. At 12-month followup 79 of 109 patients (73%) reported being continent or improved. Preoperatively, 43% of patients reported using 1 or no pads daily. At 3, 6 and 12 months 69%, 70% and 72% of patients, respectively, required 1 or no pads daily. On urodynamic evaluation at 12-month followup 76.0% of the patients did not leak with a Valsalva maneuver. A total of 30 cases were classified as failures and 11 women were lost to followup. There were no intraoperative complications, 3 (4%) minor postoperative complications which resolved, and no device related complications. The transvaginal radio frequency applicator demonstrated good efficacy and excellent safety at 1-year followup. Ongoing analysis of the data has indicated opportunities for improvement of this new surgical technique that could result in higher efficacy rates without compromising safety. Further long-term evaluation is being conducted to assess chronic durability of the procedure.
Ultrasound Metrology in Mexico: a round robin test for medical diagnostics
NASA Astrophysics Data System (ADS)
Amezola Luna, R.; López Sánchez, A. L.; Elías Juárez, A. A.
2011-02-01
This paper presents preliminary statistical results from an on-going imaging medical ultrasound study, of particular relevance for gynecology and obstetrics areas. Its scope is twofold, firstly to compile the medical ultrasound infrastructure available in cities of Queretaro-Mexico, and second to promote the use of traceable measurement standards as a key aspect to assure quality of ultrasound examinations performed by medical specialists. The experimental methodology is based on a round robin test using an ultrasound phantom for medical imaging. The physician, using its own ultrasound machine, couplant and facilities, measures the size and depth of a set of pre-defined reflecting and absorbing targets of the reference phantom, which simulate human illnesses. Measurements performed give the medical specialist an objective feedback regarding some performance characteristics of their ultrasound examination systems, such as measurement system accuracy, dead zone, axial resolution, depth of penetration and anechoic targets detection. By the end of March 2010, 66 entities with medical ultrasound facilities, from both public and private institutions, have performed measurements. A network of medical ultrasound calibration laboratories in Mexico, with traceability to The International System of Units via national measurement standards, may indeed contribute to reduce measurement deviations and thus attain better diagnostics.
Heneghan, Carl J; Goldacre, Ben; Onakpoya, Igho; Aronson, Jeffrey K; Jefferson, Tom; Pluddemann, Annette; Mahtani, Kamal R
2017-12-06
Transvaginal mesh devices are approved in the USA by the Food and Drug Administration (FDA), through the 510(k) system. However, there is uncertainty about the benefit to harm balance of mesh approved for pelvic organ prolapse. We, therefore, assessed the evidence at the time of approval for transvaginal mesh products and the impact of safety studies the FDA mandated in 2012 because of emerging harms. We used FDA databases to determine the evidence for approval of transvaginal mesh. To create a 'family tree' of device equivalence, we used the 510(k) regulatory approval of the 1985 Mersilene Mesh (Ethicon) and the 1996 ProteGen Sling (Boston Scientific), searched for all subsequently related device approvals, and for the first published randomised trial evidence. We assessed compliance with all FDA 522 orders issued in 2012 requiring postmarketing surveillance studies. We found 61 devices whose approval ultimately relied on claimed equivalence to the Mersilene Mesh and the ProteGen Sling. We found no clinical trials evidence for these 61 devices at the time of approval. Publication of randomised clinical trials occurred at a median of 5 years after device approval (range 1-14 years). Analysis of 119 FDA 522 orders revealed that in 79 (66%) the manufacturer ceased market distribution of the device, and in 26 (22%) the manufacturer had changed the indication. Only seven studies (six cohorts and new randomised controlled trial) covering 11 orders were recruiting participants (none had reported outcomes). Transvaginal mesh products for pelvic organ prolapse have been approved on the basis of weak evidence over the last 20 years. Devices have inherited approval status from a few products. A publicly accessible registry of licensed invasive devices, with details of marketing status and linked evidence, should be created and maintained at the time of approval. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Liang, Ching-Chung; Lo, Tsia-Shu; Tseng, Ling-Hong; Lin, Yi-Hao; Lin, Yu-Jr; Chang, Shuenn-Dhy
2012-10-01
Synthetic mesh kits recently adopted in pelvic reconstructive surgeries have achieved great surgical efficacy, but the effects of transvaginal synthetic mesh procedures on women's sexual function are still controversial. This study was conducted to demonstrate sexual function in women before and after surgery with transvaginal mesh (TVM) repair for pelvic organ prolapse (POP). A total of 93 sexually active women scheduled for correcting POP with synthetic mesh kits were recruited. In addition to urogynecological history, pelvic examination by the Pelvic Organ Prolapse Quantification system, and urodynamic testing, consenting participants were asked to complete the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) to evaluate sexual function before and after surgery. At the 3-month urodynamic studies, among the 25 patients with coexistent urodynamic stress incontinence (USI) who had undergone a concomitant transobturator suburethral tape procedure (TOT), 1 (4 %) had persistent USI; 8 of 68 (11.8 %) patients with a negative pessary test developed postoperative USI. Six-month prolapse recurrence rates following TVM alone and TVM with concomitant TOT were 9 and 12 %, respectively. The total PISQ-12 score after surgery showed worse results in the TVM alone group but not in the TVM with concomitant TOT group. The individual scores of PISQ-12 after surgery demonstrated prolapse-related items improved in both TVM groups; sexual function worsened in dyspareunia and behavior domains. Our data revealed that transvaginal synthetic mesh procedures for the treatment of POP generated favorable clinical outcomes, but situations might worsen in dyspareunia and behavior domains, thereby invoking a negative emotional reaction during intercourse after surgery.
Teoh, Anthony Yuen Bun; Ng, Enders Kwok Wai; Chock, Alana; Swanstrom, Lee; Varadarajulu, Shyam; Chiu, Philip Wai Yan
2014-05-01
Patient and physician perceptions of natural orifice transluminal endoscopic surgery (NOTES) have been reported for the Western population. However, whether Asian-Chinese patients share the same perspectives as compared to the Western population is unknown. This was a cross-sectional survey carried out in the surgical outpatient's clinic at the Prince of Wales Hospital between June and September 2011. Patients were provided with an information leaflet and asked to complete a questionnaire regarding their perceptions of and preferences for NOTES cholecystectomy. Female patients attending the clinic were given an additional questionnaire regarding attitudes towards transvaginal surgery. Two hundred patients were recruited to complete the questionnaire(s) and the male to female ratio was 1:1. One hundred and fourteen patients (57%) preferred to undergo NOTES cholecystectomy for cosmetic reasons (P=0.009). Oral and anal routes were both acceptable for NOTES accesses in males and females. Forty-one percent of the female patients would consider transvaginal NOTES. Of these patients, significantly more patients indicated that the reason for choosing transvaginal NOTES was to minimize the risk of hernia (P=0.016) and to reduce pain associated with the procedure (P=0.017). The risk of complications (84.5%) and the cost of the procedure (58%) were considered the most important aspects when choosing a surgical approach by Asian-Chinese patients. Asian-Chinese preferred NOTES mainly for cosmetic reasons. However, the transvaginal route was less acceptable to females. Significant differences in patient perception on NOTES were observed between Asian-Chinese and Western patients. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Detection Rate and Sonographic Signs of Trisomy 21 Fetuses at 14-17 Weeks of Gestation.
Bronshtein, Eliezer; Solt, Ido; Bronshtein, Moshe; Gover, Ayala; Wolman, Igal; Blumenfeld, Zeev
2017-01-01
Early prenatal ultrasound is an important part of prenatal screening in Israel. No studies have described the rate of trisomy 21 [T21] identification at 14-17 weeks gestation. To describe the rate of T21 identification by transvaginal sonograms (TVS) at 14-17 weeks gestation. We conducted a historical prospective study. Since 1986, early TVS of 72,000 fetuses at 14-17 weeks gestation have been prospectively recorded together with prenatal screening data at a private ultrasound center (AL-KOL, Haifa). We calculated the fraction of T21 cases by dividing the total number of cases with abnormal sonographic findings by the total number of diagnosed T21 cases. We also examined the percentage of verified T21 cases that had completely normal prenatal screening tests prior to the early prenatal TVS, thus revealing the contribution of this examination to the existing prenatal screening. Fisher's exact test was used to calculate odds ratios for each sonographic marker. Of 137 T21 fetuses, 123 had sonographic markers on early TVS, yielding a prediction capability of at least 89.87%. Of all T21 cases, 14% had completely normal nuchal translucency/first-trimester screening prior to the abnormal 14-17 week TVS findings. Isolated abnormal sonographic findings, which were found to increase the risk for T21, were common atrioventricular septal canal (odds ratio 88.88), duodenal atresia (OR 88.23), nuchal edema (OR 39.14), and hydrocephalus (OR 15.78). Fetal hydronephrosis/pyelectasis was non-significant when isolated (OR 1), and cardiac echogenic focus was associated with a decreased risk (OR 0.13). Early prenatal TVS at 14-17 weeks may identify almost 90% of T21 and adds 14% to the identification rate at the first-trimester screening.
Matsuzaki, Toshiya; Munkhzaya, Munkhsaikhan; Iwasa, Takeshi; Tungalagsuvd, Altankhuu; Yano, Kiyohito; Mayila, Yiliyasi; Yanagihara, Rie; Tokui, Takako; Kato, Takeshi; Kuwahara, Akira; Matsui, Sumika; Irahara, Minoru
2017-05-30
Polycystic ovary syndrome (PCOS) is an ovulatory disorder that affects 6-10% of women of reproductive age. Serum AMH level may be an additional factor, or surrogate of PCOM, in the diagnostic criteria of PCOS. We evaluated the correlations between the serum AMH level and various endocrine and metabolic features in PCOS using the latest fully automated assay. Serum AMH level was compared between 114 PCOS patient (PCOS group) and 95 normal menstrual cycle women (Control group). Correlations between serum AMH level and various endocrine and metabolic factors were analysed in PCOS group. The serum AMH level was significantly higher in the PCOS group (8.35±8.19 ng/mL) than in the Control group (4.99±3.23 ng/mL). The serum AMH level was independently affected by age and the presence of PCOS on multiple regression analysis. Ovarian volume per ovary (OPVO) showed the strongest positive correlation (r=0.62) with the serum AMH level among related factors. On receiver operating characteristic (ROC) curve analysis, the cut-off value of AMH for the diagnosis of PCOS was 7.33 ng/mL, but this value did not have high efficacy (sensitivity 44.7%, specificity 76.8%). A cut-off value of 10 ng/mL had a high specificity of 92.6%, although the sensitivity was low (24.6%). The serum AMH level was elevated and reflected ovarian size in PCOS patients. The serum AMH level could be a surrogate for ultrasound findings of the ovaries in PCOS and might be useful for estimating ovarian findings without transvaginal ultrasound in the diagnosis of PCOS.
Hughes, Kelly; Sim, Shirlene; Roman, Alina; Michalak, Kasia; Kane, Stefan; Sheehan, Penelope
2017-08-01
Preterm birth continues to be a major cause of infant morbidity and mortality worldwide, but advances have recently been made in its prediction and prevention. A short cervix (<25 mm) in the second trimester on transvaginal ultrasound scan and fetal fibronectin are important predictive tests. For over ten years, the Preterm Labour Clinic at the Royal Women's Hospital, Melbourne, Australia has provided care for women at high risk of preterm birth, including those with a previous preterm birth, previous cervical surgery, uterine malformation or incidental finding of short cervix at routine ultrasound. The purpose of this study was to review this clinic's outcomes for the first decade. This was a retrospective cohort study of all referrals to the Preterm Labour Clinic during the period 2004-2013 inclusive. Seven hundred and fifty-six cases met the study inclusion criteria of appropriate risk factor, singleton pregnancy, surveillance undertaken and outcome data available. The preterm birth rate (<37 weeks) was 21.4%. The rate of preterm birth by year decreased significantly when adjusted for risk (P = 0.002). A short cervix was diagnosed in 32% of the sample, and positively correlated with lower gestational age at delivery. Fetal fibronectin and serum alkaline phosphatase were independent predictors of preterm birth <34 weeks and <37 weeks. The adjusted preterm birth rate at the Royal Women's Hospital's Preterm Labour Clinic has decreased significantly over the decade studied. Positive fetal fibronectin at 26 weeks and elevated serum alkaline phosphatase are independent predictors of preterm birth. © 2017 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Infante, Fernando; Espada Vaquero, Mercedes; Bignardi, Tommaso; Lu, Chuan; Testa, Antonia C; Fauchon, David; Epstein, Elisabeth; Leone, Francesco P G; Van den Bosch, Thierry; Martins, Wellington P; Condous, George
2018-06-01
To assess interobserver reproducibility in detecting tubal ectopic pregnancies by reading data sets from 3-dimensional (3D) transvaginal ultrasonography (TVUS) and comparing it with real-time 2-dimensional (2D) TVUS. Images were initially classified as showing pregnancies of unknown location or tubal ectopic pregnancies on real time 2D TVUS by an experienced sonologist, who acquired 5 3D volumes. Data sets were analyzed offline by 5 observers who had to classify each case as ectopic pregnancy or pregnancy of unknown location. The interobserver reproducibility was evaluated by the Fleiss κ statistic. The performance of each observer in predicting ectopic pregnancies was compared to that of the experienced sonologist. Women were followed until they were reclassified as follows: (1) failed pregnancy of unknown location; (2) intrauterine pregnancy; (3) ectopic pregnancy; or (4) persistent pregnancy of unknown location. Sixty-one women were included. The agreement between reading offline 3D data sets and the first real-time 2D TVUS was very good (80%-82%; κ = 0.89). The overall interobserver agreement among observers reading offline 3D data sets was moderate (κ = 0.52). The diagnostic performance of experienced observers reading offline 3D data sets had accuracy of 78.3% to 85.0%, sensitivity of 66.7% to 81.3%, specificity of 79.5% to 88.4%, positive predictive value of 57.1% to 72.2%, and negative predictive value of 87.5% to 91.3%, compared to the experienced sonologist's real-time 2D TVUS: accuracy of 94.5%, sensitivity of 94.4%, specificity of 94.5%, positive predictive value of 85.0%, and negative predictive value of 98.1%. The diagnostic accuracy of 3D TVUS by reading offline data sets for predicting ectopic pregnancies is dependent on experience. Reading only static 3D data sets without clinical information does not match the diagnostic performance of real time 2D TVUS combined with clinical information obtained during the scan. © 2017 by the American Institute of Ultrasound in Medicine.
Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G
2015-06-01
To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of vascular indices or endometrial volume. The optimal imaging modality appears to be real-time 2D-GIS. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
The effects of ovarian biopsy and blood sampling methods on salivary cortisol and behaviour in sows.
Yun, Jinhyeon; Björkman, Stefan; Pöytäkangas, Merja; Peltoniemi, Olli
2017-10-01
In reproductive physiology research, experimental animals are often subjected to stressful procedures, including blood sampling and biopsy. In this present study, presence of pain or distress induced by four different procedures was examined using a measurement of salivary cortisol levels and activity observations in sows. The treatments were: 1) PAL: The ovary was palpated through the rectum without snaring, 2) TUB: transvaginal ultrasound-guided biopsy of the ovary was conducted without snaring, 3) SNA: a soft rope snare was placed around the maxilla, 4) CAT: A soft rope snare was placed around the maxilla, and an intravenous catheter was inserted through the ear vein of the sows. Activities, social cohesion and other pain-related behaviour, and salivary cortisol concentrations were recorded. Salivary cortisol concentrations in CAT sows increased in response to the procedure (P<0.05), whereas the other treatments did not trigger a significant response. The CAT sows had higher cortisol concentrations than the other groups for 10min after initiation of the procedures (P<0.01), and they maintained higher cortisol levels than the PAL and TUB groups 15min post-treatment (P<0.05). Furthermore, the CAT sows showed the highest frequency of head shaking (P<0.001) and trembling behaviour (P<0.05) during the 1h post-treatment. Summarizing, the catheterization procedure might induce a short-term pain or stress response during and after the procedure in terms of pain-related behaviour and salivary cortisol status. We suggest that TUB might not cause appreciable pain or distress. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kadour-Peero, Einav; Sagi-Dain, Lena; Cohen, Gil; Korobochka, Roman; Agbarya, Abed; Bejar, Jacob; Sagi, Shlomi
2018-05-07
BACKGROUND There is now evidence to support that some cases of high-grade serous papillary carcinoma arise from the fallopian tubes rather than the ovaries. Common symptoms at presentation include abdominal pain and swelling, vomiting, altered bowel habit and urinary symptoms. To our knowledge, this is the first case of serous papillary carcinoma presenting as a vaginal mass lesion. CASE REPORT A 41-year-old woman was referred to the Bnai-Zion Medical Center with the main complaint of irregular vaginal bleeding, vaginal mucous discharge, and suspected pelvic mass. Physical examination showed a soft, painless mass, measuring about 10 cm in diameter located mainly in the recto-vaginal septum, but not involving the uterus. Ultrasound examination showed no abnormal ovarian or uterine findings. Transvaginal biopsies of the mass showed a poorly differentiated serous papillary carcinoma of ovarian, tubal, or peritoneal origin. The physical examination and imaging findings strongly indicated an inoperable tumor, and the patient was treated with neoadjuvant (pre-surgical) chemotherapy. Pre-operative computed tomography (CT) imaging showed the partial involvement of the colon, and so surgical treatment included total abdominal hysterectomy, bilateral salpingo-oophorectomy, omentectomy, partial vaginectomy, anterior rectal resection, and lymph node dissection. Histopathology of the surgical specimens showed a poorly differentiated serous carcinoma originating from the fimbria of the right fallopian tube. CONCLUSIONS To the best of our knowledge, this is the first report to describe primary fallopian tube papillary serous carcinoma presenting as a vaginal mass. Therefore, physicians should be aware of this possible diagnosis.
Conde-Agudelo, Agustin; Romero, Roberto
2015-12-01
To determine the accuracy of changes in transvaginal sonographic cervical length over time in predicting preterm birth in women with singleton and twin gestations. PubMed, Embase, Cinahl, Lilacs, and Medion (all from inception to June 30, 2015), bibliographies, Google scholar, and conference proceedings. Cohort or cross-sectional studies reporting on the predictive accuracy for preterm birth of changes in cervical length over time. Two reviewers independently selected studies, assessed the risk of bias, and extracted the data. Summary receiver-operating characteristic curves, pooled sensitivities and specificities, and summary likelihood ratios were generated. Fourteen studies met the inclusion criteria, of which 7 provided data on singleton gestations (3374 women) and 8 on twin gestations (1024 women). Among women with singleton gestations, the shortening of cervical length over time had a low predictive accuracy for preterm birth at <37 and <35 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 49% to 74%, 44% to 85%, 1.3 to 4.1, and 0.3 to 0.7, respectively. In women with twin gestations, the shortening of cervical length over time had a low to moderate predictive accuracy for preterm birth at <34, <32, <30, and <28 weeks of gestation with pooled sensitivities and specificities, and summary positive and negative likelihood ratios ranging from 47% to 73%, 84% to 89%, 3.8 to 5.3, and 0.3 to 0.6, respectively. There were no statistically significant differences between the predictive accuracies for preterm birth of cervical length shortening over time and the single initial and/or final cervical length measurement in 8 of 11 studies that provided data for making these comparisons. In the largest and highest-quality study, a single measurement of cervical length obtained at 24 or 28 weeks of gestation was significantly more predictive of preterm birth than any decrease in cervical length between these gestational ages. Change in transvaginal sonographic cervical length over time is not a clinically useful test to predict preterm birth in women with singleton or twin gestations. A single cervical length measurement obtained between 18 and 24 weeks of gestation appears to be a better test to predict preterm birth than changes in cervical length over time. Published by Elsevier Inc.
Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun
2015-01-01
Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology PMID:26119166
Guarino, Antonella; Di Benedetto, Luisa; Assorgi, Chiara; Rocca, Alessandra; Caserta, Donatella
2015-01-01
The term retained products of conception (RPOC) refers to intrauterine tissue that develops after conception and persists after medical and surgical pregnancy termination, miscarriage, and vaginal or cesarean delivery. One of the most important factor risk for RPOC is placenta accreta, defined as "the abnormal adherence, either in whole or in part, of the afterbirth to the underlying uterine wall". We report a case of a 37 years old woman referred to our gynecologic department with irregular vaginal bleeding. On her medical history, she had a cesarean occurred 3 months before. Ultrasonography revealed in the uterine cavity hyperechoic mass, treated with curettage. Two weeks later the curettage, patient complained still vaginal bleeding. On the transvaginal ultrasound, the uterine cavity was occupied again by a hyperechoic mass. She underwent to hysteroscopic resection and histological diagnosis was compatible with placenta accreta residual. In the follow up she had not complications. Early diagnosis, prompt evaluation of bleeding is important for timely treatment and for preventing immediate complications and demolitive approach. A careful follow up is necessary to prevent late consequences. The purpose of this study is to report our experience in timely diagnosis and conservative management.
Assisted reproduction techniques in the horse.
Hinrichs, Katrin
2012-01-01
This paper reviews current equine assisted reproduction techniques. Embryo transfer is the most common equine ART, but is still limited by the inability to superovulate mares effectively. Immature oocytes may be recovered by transvaginal ultrasound-guided aspiration of immature follicles, or from ovaries postmortem, and can be effectively matured in vitro. Notably, the in vivo-matured oocyte may be easily recovered from the stimulated preovulatory follicle. Standard IVF is still not repeatable in the horse; however, embryos and foals can be produced by surgical transfer of mature oocytes to the oviducts of inseminated recipient mares or via intracytoplasmic sperm injection (ICSI). Currently, ICSI and in vitro embryo culture are routinely performed by only a few laboratories, but reported blastocyst development rates approach those found after bovine IVF (i.e. 25%-35%). Nuclear transfer can be relatively efficient (up to 26% live foal rate per transferred embryo), but few laboratories are working in this area. Equine blastocysts may be biopsied via micromanipulation, with normal pregnancy rates after biopsy, and accurate genetic analysis. Equine expanded blastocysts may be vitrified after collapsing them via micromanipulation, with normal pregnancy rates after warming and transfer. Many of these recently developed techniques are now in clinical use.
Successful ongoing pregnancies after vitrification of oocytes.
Lucena, Elkin; Bernal, Diana Patricia; Lucena, Carolina; Rojas, Alejandro; Moran, Abby; Lucena, Andrés
2006-01-01
To demonstrate the efficiency of vitrifying mature human oocytes for different clinical indications. Descriptive case series. Cryobiology laboratory, Centro Colombiano de Fertilidad y Esterilidad-CECOLFES LTDA. (Bogotá, Colombia). Oocyte vitrification was offered as an alternative management for patients undergoing infertility treatment because of ovarian hyperstimulation syndrome, premature ovarian failure, natural ovarian failure, male factor, poor response, or oocyte donation. Mature oocytes were obtained from 33 donor women and 40 patients undergoing infertility treatment. Oocytes were retrieved by ultrasound-guided transvaginal aspiration and vitrified with the Cryotops method, with 30% ethylene glycol, 30% dimethyl sulfoxide, and 0.5 mol/L sucrose. Viability was assessed 3 hours after thawing. The surviving oocytes were inseminated by intracytoplasmic sperm injection. Fertilization was evaluated after 24 hours. The zygotes were further cultured in vitro for up to 72 hours until time of embryo transfer. Recovery, viability, fertilization, and pregnancy rates. Oocyte vitrification with the Cryotop method resulted in high rates of recovery, viability, fertilization, cleavage, and ongoing pregnancy. Vitrification with the Cryotop method is an efficient, fast, and economical method for oocyte cryopreservation that offers high rates of survival, fertilization, embryo development, and ongoing normal pregnancies, providing a new alternative for the management of female infertility.
Noh, Dong K; Lee, Jae J; You, Joshua H
2014-01-01
Recent ultrasound imaging evidence asserts that the diaphragm is an important multifunctional muscle to control breathing as well as stabilize the core and posture in humans. However, the validity and accuracy of ultrasound for the measurement of dynamic diaphragm movements during breathing and functional core activities have not been determined. The specific aim of this study was to validate the accuracy of ultrasound imaging measurements of diaphragm movements by concurrently comparing these measurements to the gold standard of radiographic imaging measurements. A total of 14 asymptomatic adults (9 males, 5 females; mean age =28.4 ± 3.0 years) were recruited to participate in the study. Ultrasound and radiographic images were used concurrently to determine diaphragm movement (inspiration, expiration, and excursion) during tidal breathing. Pearson correlation analysis showed strong correlations, ranging from r=0.78 to r=0.83, between ultrasound and radiographic imaging measurements of the diaphragm during inhalation, exhalation, and excursion. These findings suggest that ultrasound imaging measurement is useful to accurately evaluate diaphragm movements during tidal breathing. Clinically, ultrasound imaging measurements can be used to diagnose and treat diaphragm movement impairments in individuals with neuromuscular disorders including spinal cord injuries, stroke, and multiple sclerosis.
Bouzid, A; Ayachi, A; Ben Khedija, M; Menjli, S; Mkaouar, L; Mourali, M
2016-11-01
The aim of our study is to evaluate the feasibility, safety and diagnostic value of hysterosonography performed in an emergency setting among patients consulting for active abnormal uterine bleeding. In this prospective study, we included 216 patients visiting our emergency department for abnormal uterine bleeding. All patients had a transvaginal ultrasound with doppler study and an hysterosonography. Secondly, the patients, in whom we diagnosed a suspected organic lesion, were addressed to an endoscopic or surgical procedure with pathological examination. Initially, we evaluated the feasibility and the safety of hysterosonography and secondly, we compared the two techniques (EEV and hysterosonography), sensitivity, specificity, LHR+and LHR-. The hysterosonography was performed in 98.1 % of patients and its realization has resulted in an additional period of 1.2minutes on average (extreme: 6-12) compared to ultrasound. The tolerance of the hysterosonographic examination was very good in 73.5 % of patients and good in 23.1 % of them. For the 167 patients who had been diagnosed with presumed organic lesions, pathological examination found an endometrial hyperplasia in 34.7 % of cases, polyps in 40.1 % of cases, sub-mucosal fibroids in 11.3 % of cases, endometrial cancer in 0.7 % of cases and other lesions in 13.2 % of cases. The diagnostic value of hysterosonography was superior to ultrasound in the detection of polyps (AUC: 0.894 vs 0.778, P=0.003) and fibromas (AUC: 1.000 vs 0.716, P=0.001) while the two methods showed no significant difference in the detection of hyperplasia. The purpose of our study was to focus on a particular context of use of the hysterosonography consisting on hemorrhagic period and on its realization in the emergency room. We were able to demonstrate that hysterosonography is compatible with the emergency situation as to its feasibility and its diagnostic value and that its realization would contribute to the sorting of patients to guide them immediately to a surgical or endoscopic procedure if necessary. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Vergeldt, T F M; Notten, K J B; Stoker, J; Fütterer, J J; Beets-Tan, R G; Vliegen, R F A; Schweitzer, K J; Mulder, F E M; van Kuijk, S M J; Roovers, J P W R; Kluivers, K B; Weemhoff, M
2016-05-01
To compare translabial three-dimensional (3D) ultrasound with magnetic resonance imaging (MRI) for the measurement of levator hiatal biometry at rest in women with pelvic organ prolapse, and to determine the interobserver reliability between two independent observers for ultrasound and MRI measurements. Data were derived from a multicenter prospective cohort study in which women scheduled for conventional anterior colporrhaphy underwent translabial 3D ultrasound and MRI prior to surgery. Intraclass correlation coefficients (ICCs) were calculated to estimate interobserver reliability between two independent observers and determine the agreement between ultrasound and MRI measurements. Bland-Altman plots were created to assess the agreement between ultrasound and MRI measurements. Data from 139 women from nine hospitals were included in the study. The interobserver reliability of ultrasound assessment at rest, during Valsalva maneuver and during contraction and of MRI assessment at rest were moderate or good. The agreement between ultrasound and MRI for the measurement of levator hiatal biometry at rest was moderate, with ICCs of 0.52 (95%CI, 0.32-0.66) for levator hiatal area, 0.44 (95%CI, 0.21-0.60) for anteroposterior diameter and 0.44 (95%CI, 0.22-0.60) for transverse diameter. Levator hiatal biometry measurements were statistically significantly larger on MRI than on translabial 3D ultrasound. The agreement between translabial 3D ultrasound and MRI for measurement of the levator hiatus at rest in women with pelvic organ prolapse was only moderate. The results of translabial 3D ultrasound and MRI should therefore not be used interchangeably in daily practice or in clinical research. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Is robotic sacrocolpopexy a marketing gimmick or a technological advancement?
Kim, Ja-Hong; Anger, Jennifer T
2010-07-01
Robot-assisted laparoscopic sacrocolpopexy (RALS) is a new surgical technique for the treatment of symptomatic vaginal vault prolapse that is rapidly gaining popularity among both urologists and gynecologists. This article will summarize the available published data to assess the potential advantages and disadvantages of this new procedure and its current role in female pelvic floor reconstruction. The literature on RALS is limited mainly to single-institution retrospective studies, which suggest minimal morbidity, technical feasibility, and short-term efficacy comparable to open abdominal sacrocolpopexy. What remains uncertain is whether this approach will be superior to the other established minimally invasive transvaginal and laparoscopic approaches in terms of subjective and objective outcomes and quality of life. Other relevant issues, such as overall cost-effectiveness and extended application for multicompartment defects and uterine-sparing procedures, remain largely unexplored. The use of RALS will likely continue to expand secondary to increased access and the popularity of the robotic apparatus among both surgeons and patients. Well designed large randomized multicenter comparative studies based on validated measurement instruments are needed to evaluate its advantage over conventional approaches, including open abdominal sacrocolpopexy and various transvaginal and laparoscopic techniques.
Dückelmann, A M; Bamberg, C; Michaelis, S A M; Lange, J; Nonnenmacher, A; Dudenhausen, J W; Kalache, K D
2010-02-01
To assess whether ultrasound experience or fetal head station affects the reliability of measurement of fetal head descent using the angle of progression on intrapartum ultrasound images obtained by a single experienced operator, and to determine reliability of measurements when images were acquired by different operators with variable ultrasound experience. One experienced obstetrician performed 44 transperineal ultrasound examinations of women at term and in prolonged second stage of labor with the fetus in the occipitoanterior position. Three midwives without ultrasound experience, three obstetricians with < 5 years' experience and three obstetricians with > 10 years' experience measured fetal head descent based on the angle of progression in the images obtained. The angle of progression was measured by two obstetricians in independent ultrasound examinations of 24 laboring women at term with the fetus in the cephalic position to allow assessment of the reliability of image acquisition. Intraclass correlation coefficients (ICCs) with 95% confidence interval (CI) were used to evaluate interobserver reliability and Bland-Altman analysis was used to assess interobserver agreement. In total, 444 measurements were performed and compared. Interobserver reliability with respect to offline image analysis was substantial (overall ICC, 0.72; 95% CI, 0.63-0.81). ICCs were 0.82 (95% CI, 0.70-0.89), 0.81 (95% CI, 0.71-0.88) and 0.61 (95% CI, 0.43-074) for observers with > 10 years', < 5 years' and no ultrasound experience, respectively. There were no significant differences between ICCs among observer groups according to ultrasound experience. Fetal head station did not affect reliability. Bland-Altman analysis indicated reasonable agreement between measurements obtained by two different operators with > 10 years' and < 5 years' ultrasound experience (bias, -1.09 degrees ; 95% limits of agreement, -8.76 to 6.58). The reliability of measurement of the angle of progression following separate image acquisition by two experienced operators was similar to the reliability of offline image analysis (ICC, 0.86; 95% CI, 0.70-0.93). Measurement of the angle of progression on transperineal ultrasound imaging is reliable regardless of fetal head station or the clinician's level of ultrasound experience.
Measuring Femoral Torsion In Vivo Using Freehand 3-D Ultrasound Imaging.
Passmore, Elyse; Pandy, Marcus G; Graham, H Kerr; Sangeux, Morgan
2016-02-01
Despite variation in bone geometry, muscle and joint function is often investigated using generic musculoskeletal models. Patient-specific bone geometry can be obtained from computerised tomography, which involves ionising radiation, or magnetic resonance imaging (MRI), which is costly and time consuming. Freehand 3-D ultrasound provides an alternative to obtain bony geometry. The purpose of this study was to determine the accuracy and repeatability of 3-D ultrasound in measuring femoral torsion. Measurements of femoral torsion were performed on 10 healthy adults using MRI and 3-D ultrasound. Measurements of femoral torsion from 3-D ultrasound were, on average, smaller than those from MRI (mean difference = 1.8°; 95% confidence interval: -3.9°, 7.5°). MRI and 3-D ultrasound had Bland and Altman repeatability coefficients of 3.1° and 3.7°, respectively. Accurate measurements of femoral torsion were obtained with 3-D ultrasound offering the potential to acquire patient-specific bone geometry for musculoskeletal modelling. Three-dimensional ultrasound is non-invasive and relatively inexpensive and can be integrated into gait analysis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Kapoor, Rakesh; Ansari, M. S.; Singh, Pratipal; Gupta, Parag; Khurana, Naval; Mandhani, Anil; Dubey, Deepak; Srivastava, Aneesh; Kumar, Anant
2007-01-01
Purpose: We aim to present our experience for the repair of vesicovaginal fistula (VVF) with special reference to surgical approach. Materials and Methods: From January 1999 to June 2005, 52 VVF patients with mean age of 32 years underwent operative treatment. Fistulas were divided into two groups, simple and complex, depending on site, size, etiology and associated anomalies. Simple VVFs were approached through the vaginal route and complex VVFs via the transabdominal route. Patients were evaluated at two to three weeks initially, three-monthly twice and later depending on symptoms. Results: Thirty-two (61.5%) had simple fistulas and 20 (38.5%) complex fistulas. The most common etiology was obstetric trauma in 31 (59.6%) patients, while the second most common cause was post hysterectomy VVF. Thirty-two (61.5%) patients were managed by transvaginal route, of which 17 had supratrigonal and 15 trigonal fistulas. Twenty (38.5%) patients with complex fistulas were managed by abdominal route. The mean blood loss, postoperative pain and mean hospital stay were shorter in transvaginal repair. Eleven (21.2%) patients required ancillary procedures for various other associated anomalies at the time of fistula repair. Three patients failed repair giving a success rate of 94.2%. At a mean follow-up of three years 48 women were sexually active, of these 10 (19.2%) complained of mild to moderate dyspareunia. Conclusion: Most of the simple fistulas irrespective their locations are easily accessible transvaginally while in complex fistulas we recommend the transabdominal approach. Depending on the clinical context both the approaches achieved comparable success rates. PMID:19718291
Sonographic features of incidentally detected, small, nonpalpable ovarian dermoids.
Serafini, G; Quadri, P G; Gandolfo, N G; Gandolfo, N; Martinoli, C; Derchi, L E
1999-09-01
We describe the transvaginal sonographic features of incidentally detected, small, nonpalpable ovarian dermoid cysts. A total of 38 small (less than 3 cm in diameter), nonpalpable, incidentally discovered ovarian dermoids in 35 women were retrospectively reviewed; 3 patients had small bilateral lesions, and 7 had a small ovarian dermoid detected during preoperative evaluation of a symptomatic, large, contralateral lesion. Transvaginal sonography permitted identification of all 38 dermoids, whereas abdominal sonography detected only 22 of the lesions. Three main structural patterns were observed with transvaginal sonography: (1) 20 of 38 lesions had a solid, hyperechoic appearance, either homogeneous (11) or heterogeneous (9); (2) a fluid-filled area with a hyperechoic focus in its wall was seen in 10 cases; and (3) a mixed pattern, with solid and liquid areas, was seen in 8 cases. Calcifications were appreciated in 7 lesions. Acoustic shadowing was noted in 30 cases, either as a shadow posterior to the hyperechoic portion of the mass or as an edge shadow lateral to the lesion. Doppler studies were obtained for 20 lesions but proved inconclusive: 4 mixed-pattern dermoids had a few internal signals with a low resistance pattern; in the remaining cases, there were signals at the periphery of the cysts, but it could not be determined whether these were from vessels within the lesions or from vessels in the surrounding ovarian parenchyma. Surgery confirmed benign cystic dermoids in all 38 cases. Sonographically, small ovarian dermoids have a variety of textural patterns quite similar to those encountered in large, symptomatic lesions. The increased resolution capabilities provided by transvaginal sonography allow incidental detection of previously unsuspected dermoids and permit identification of their nature. Copyright 1999 John Wiley & Sons, Inc.
Schmitz, Randy J; Wang, Hsin-Min; Polprasert, Daniel R; Kraft, Robert A; Pietrosimone, Brian G
2017-03-01
Establishing clinically accessible measures of cartilage health is critical for assessing effectiveness of protocols to reduce risk of osteoarthritis (OA) development and progression. Cartilage thickness is one important measure in describing both OA development and progression. The objective was to determine the relationship between ultrasound and MRI measures of cartilage thickness in the medial femoral condyle. Mean cartilage thicknesses of the left medial femoral cartilage were measured via T1 weighted MRI and ultrasound imaging from transverse, anterior, middle, and posterior medial femoral regions in 10 healthy females (Mean±Std Dev) (1.66±0.08m, 59.5±8.3kg, 21.6±1.4years) and nine healthy males (1.80±0.08m, 79.1±6.2kg, 21.7±1.5years). Pearson correlations examined relationships between MRI and ultrasound measures. Bland-Altman plots evaluated agreement between the imaging modalities. Transverse ultrasound thickness measures were significantly positively correlated with MRI middle (r=.67, P≤.05) and posterior thicknesses (r=.49, P≤.05) while the middle and posterior longitudinal ultrasound measures were significantly correlated to their respective MRI regions (r=.67, P≤.05 & r=.59 P≤.05, respectively). There was poor absolute agreement between correlated measures with ultrasound thickness measures being between 1.9 and 2.8mm smaller than MRI measures. These results suggest that ultrasound may be a viable clinical tool to assess relative cartilage thickness in the middle and posterior medial femoral regions. However, the absolute validity of the ultrasound measure is called into question due to the larger MRI-based thickness measures. Level IV. Copyright © 2016 Elsevier B.V. All rights reserved.
Spinal curvature measurement by tracked ultrasound snapshots.
Ungi, Tamas; King, Franklin; Kempston, Michael; Keri, Zsuzsanna; Lasso, Andras; Mousavi, Parvin; Rudan, John; Borschneck, Daniel P; Fichtinger, Gabor
2014-02-01
Monitoring spinal curvature in adolescent kyphoscoliosis requires regular radiographic examinations; however, the applied ionizing radiation increases the risk of cancer. Ultrasound imaging is favored over radiography because it does not emit ionizing radiation. Therefore, we tested an ultrasound system for spinal curvature measurement, with the help of spatial tracking of the ultrasound transducer. Tracked ultrasound was used to localize vertebral transverse processes as landmarks along the spine to measure curvature angles. The method was tested in two scoliotic spine models by localizing the same landmarks using both ultrasound and radiographic imaging and comparing the angles obtained. A close correlation was found between tracked ultrasound and radiographic curvature measurements. Differences between results of the two methods were 1.27 ± 0.84° (average ± SD) in an adult model and 0.96 ± 0.87° in a pediatric model. Our results suggest that tracked ultrasound may become a more tolerable and more accessible alternative to radiographic spine monitoring in adolescent kyphoscoliosis. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Comparison of portable and conventional ultrasound imaging in spinal curvature measurement
NASA Astrophysics Data System (ADS)
Yan, Christina; Tabanfar, Reza; Kempston, Michael; Borschneck, Daniel; Ungi, Tamas; Fichtinger, Gabor
2016-03-01
PURPOSE: In scoliosis monitoring, tracked ultrasound has been explored as a safer imaging alternative to traditional radiography. The use of ultrasound in spinal curvature measurement requires identification of vertebral landmarks, but bones have reduced visibility in ultrasound imaging and high quality ultrasound machines are often expensive and not portable. In this work, we investigate the image quality and measurement accuracy of a low cost and portable ultrasound machine in comparison to a standard ultrasound machine in scoliosis monitoring. METHODS: Two different kinds of ultrasound machines were tested on three human subjects, using the same position tracker and software. Spinal curves were measured in the same reference coordinate system using both ultrasound machines. Lines were defined by connecting two symmetric landmarks identified on the left and right transverse process of the same vertebrae, and spinal curvature was defined as the transverse process angle between two such lines, projected on the coronal plane. RESULTS: Three healthy volunteers were scanned by both ultrasound configurations. Three experienced observers localized transverse processes as skeletal landmarks and obtained transverse process angles in images obtained from both ultrasounds. The mean difference per transverse process angle measured was 3.00 +/-2.1°. 94% of transverse processes visualized in the Sonix Touch were also visible in the Telemed. Inter-observer error in the Telemed was 4.5° and 4.3° in the Sonix Touch. CONCLUSION: Price, convenience and accessibility suggest the Telemed to be a viable alternative in scoliosis monitoring, however further improvements in measurement protocol and image noise reduction must be completed before implementing the Telemed in the clinical setting.
Cognitive load predicts point-of-care ultrasound simulator performance.
Aldekhyl, Sara; Cavalcanti, Rodrigo B; Naismith, Laura M
2018-02-01
The ability to maintain good performance with low cognitive load is an important marker of expertise. Incorporating cognitive load measurements in the context of simulation training may help to inform judgements of competence. This exploratory study investigated relationships between demographic markers of expertise, cognitive load measures, and simulator performance in the context of point-of-care ultrasonography. Twenty-nine medical trainees and clinicians at the University of Toronto with a range of clinical ultrasound experience were recruited. Participants answered a demographic questionnaire then used an ultrasound simulator to perform targeted scanning tasks based on clinical vignettes. Participants were scored on their ability to both acquire and interpret ultrasound images. Cognitive load measures included participant self-report, eye-based physiological indices, and behavioural measures. Data were analyzed using a multilevel linear modelling approach, wherein observations were clustered by participants. Experienced participants outperformed novice participants on ultrasound image acquisition. Ultrasound image interpretation was comparable between the two groups. Ultrasound image acquisition performance was predicted by level of training, prior ultrasound training, and cognitive load. There was significant convergence between cognitive load measurement techniques. A marginal model of ultrasound image acquisition performance including prior ultrasound training and cognitive load as fixed effects provided the best overall fit for the observed data. In this proof-of-principle study, the combination of demographic and cognitive load measures provided more sensitive metrics to predict ultrasound simulator performance. Performance assessments which include cognitive load can help differentiate between levels of expertise in simulation environments, and may serve as better predictors of skill transfer to clinical practice.
Acoustic pressure measurement of pulsed ultrasound using acousto-optic diffraction
NASA Astrophysics Data System (ADS)
Jia, Lecheng; Chen, Shili; Xue, Bin; Wu, Hanzhong; Zhang, Kai; Yang, Xiaoxia; Zeng, Zhoumo
2018-01-01
Compared with continuous ultrasound wave, pulsed ultrasound has been widely used in ultrasound imaging. The aim of this work is to show the applicability of acousto-optic diffraction on pulsed ultrasound transducer. In this paper, acoustic pressure of two ultrasound transducers is measured based on Raman-Nath diffraction. The frequencies of transducers are 5MHz and 10MHz. The pulse-echo method and simulation data are used to evaluate the results. The results show that the proposed method is capable to measure the absolute sound pressure. We get a sectional view of acoustic pressure using a displacement platform as an auxiliary. Compared with the traditional sound pressure measurement methods, the proposed method is non-invasive with high sensitivity and spatial resolution.
Measurement of tissue viscoelasticity with ultrasound
NASA Astrophysics Data System (ADS)
Greenleaf, J. F.; Alizad, A.
2017-02-01
Tissue properties such as elasticity and viscosity have been shown to be related to such tissue conditions as contraction, edema, fibrosis, and fat content among others. Magnetic Resonance Elastography has shown outstanding ability to measure the elasticity and in some cases the viscosity of tissues, especially in the liver, providing the ability to stage fibrotic liver disease similarly to biopsy. We discuss ultrasound methods of measuring elasticity and viscosity in tissues. Many of these methods are becoming widely available in the extant ultrasound machines distributed throughout the world. Some of the methods to be discussed are in the developmental stage. The advantages of the ultrasound methods are that the imaging instruments are widely available and that many of the viscoelastic measurements can be made during a short addition to the normal ultrasound examination time. In addition, the measurements can be made by ultrasound repetitively and quickly allowing evaluation of dynamic physiologic function in circumstances such as muscle contraction or artery relaxation. Measurement of viscoelastic tissue mechanical properties will become a consistent part of clinical ultrasound examinations in our opinion.
Ellington, David R.; Richter, Holly E.
2013-01-01
Women are seeking care for pelvic organ prolapse (POP) in increasing numbers and a significant proportion of them will undergo a second repair for recurrence. This has initiated interest by both surgeons and industry to utilize and design prosthetic mesh materials to help augment longevity of prolapse repairs. Unfortunately, the introduction of transvaginal synthetic mesh kits for use in women was done without the benefit of Level 1 data to determine its utility compared to native tissue repair. This report summarizes the potential benefit/risks of transvaginal synthetic mesh use for POP and recommendations regarding its continued use. PMID:23563869
Watanabe, Toyohiko; Inoue, Miyabi; Ishii, Ayano; Yamato, Toyoko; Yamamoto, Masumi; Sasaki, Katsumi; Kobayashi, Yasuyuki; Araki, Motoo; Uehara, Shinya; Saika, Takashi; Kumon, Hiromi
2012-01-01
Polypropylene mesh implants for the correction of pelvic organ prolapse (POP) are now available in Japan. We developed an innovative approach for correcting POP by placing polypropylene mesh transvaginally with laparoscopic assistance. From June 2007 through March 2010, sixteen consecutive patients with symptomatic stage 2 or 3 pelvic organ prolapse underwent the laparoscopic-assisted tension-free vaginal mesh procedure at Okayama University Hospital. All patients were evaluated before and at 1, 3, 6, and 12 months after surgery. Female sexual function was also evaluated with the Female Sexual Function Index (FSFI). The procedure was performed successfully without significant complications. Fifteen of 16 patients were considered anatomically cured (93.8%) at 12 months postoperatively. One patient with a recurrent stage 3 vaginal vault prolapse required sacral colpopexy six months postoperatively. Total FSFI scores improved significantly from 10.3 ± 1.3 at baseline to 18.0 ± 1.2 at 12 months after surgery. The laparoscopic-assisted trans-vaginal mesh is a safe, effective, and simple procedure for POP repairs. The procedure not only restores anatomic relationships but also improves sexual function.
Sladkevicius, P; Installé, A; Van Den Bosch, T; Timmerman, D; Benacerraf, B; Jokubkiene, L; Di Legge, A; Votino, A; Zannoni, L; De Moor, B; De Cock, B; Van Calster, B; Valentin, L
2018-02-01
To estimate intra- and interrater agreement and reliability with regard to describing ultrasound images of the endometrium using the International Endometrial Tumor Analysis (IETA) terminology. Four expert and four non-expert raters assessed videoclips of transvaginal ultrasound examinations of the endometrium obtained from 99 women with postmenopausal bleeding and sonographic endometrial thickness ≥ 4.5 mm but without fluid in the uterine cavity. The following features were rated: endometrial echogenicity, endometrial midline, bright edge, endometrial-myometrial junction, color score, vascular pattern, irregularly branching vessels and color splashes. The color content of the endometrial scan was estimated using a visual analog scale graded from 0 to 100. To estimate intrarater agreement and reliability, the same videoclips were assessed twice with a minimum of 2 months' interval. The raters were blinded to their own results and to those of the other raters. Interrater differences in the described prevalence of most IETA variables were substantial, and some variable categories were observed rarely. Specific agreement was poor for variables with many categories. For binary variables, specific agreement was better for absence than for presence of a category. For variables with more than two outcome categories, specific agreement for expert and non-expert raters was best for not-defined endometrial midline (93% and 96%), regular endometrial-myometrial junction (72% and 70%) and three-layer endometrial pattern (67% and 56%). The grayscale ultrasound variable with the best reliability was uniform vs non-uniform echogenicity (multirater kappa (κ), 0.55 for expert and 0.52 for non-expert raters), and the variables with the lowest reliability were appearance of the endometrial-myometrial junction (κ, 0.25 and 0.16) and the nine-category endometrial echogenicity variable (κ, 0.29 and 0.28). The most reliable color Doppler variable was color score (mean weighted κ, 0.77 and 0.69). Intra- and interrater agreement and reliability were similar for experts and non-experts. Inter- and intrarater agreement and reliability when using IETA terminology were limited. This may have implications when assessing the association between a particular ultrasound feature and a specific histological diagnosis, because lack of reproducibility reduces the reliability of the association between a feature and the outcome. Future studies should investigate whether using fewer categories of variable or offering practical training could improve agreement and reliability. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Shi, Wen; Tian, Dan; Liu, Da; Yin, Jing; Huang, Ying
2017-08-01
Besides the study on examining facet joints of lumbar spine by ultrasound in normal population, there has not been any related report about examining normal facet joints of lumbar spine by ultrasound so far. This study was aimed to explore the feasibility of ultrasound assessment of lumber spine facet joints by comparing ultrasound measure values of normal and degenerative lumber spine facet joints, and by comparing measure values of ultrasound and computed tomography (CT) of degenerative lumber spine facet joints.This study included 15 patients who had chronic low back pain because of degenerative change in lumbar vertebrae, and 19 volunteers who did not have low back pain or pain in the lower limb. The ultrasound measure values (height [H] and width [W]) of normal and degenerative lumber spine facet joints were compared. And the differentiation between measure values (H and W) of ultrasound and CT of degenerative lumber spine facet joints was also analyzed.The ultrasound clearly showed abnormal facet joints lesion, which was characterized by hyperostosis on the edge of joints, bone destruction under joints, and thinner or thicker articular cartilage. There were significant differences between the ultrasound measure values of the normal (H: 1.26 ± 0.03 cm, W: 0.18 ± 0.01 cm) and abnormal facet joints (H: 1.43 ± 0.05 cm, W: 0.15 ± 0.02 cm) (all P < .05). However, there were no significant differences between the measure values of the ultrasound (H: 1.43 ± 0.17 cm, W: 0.15 ± 0.03 cm) and CT (H: 1.42 ± 0.16, W: 0.14 ± 0.03) of the degenerative lumber spine facet joints (all P > .05).Ultrasound can clearly show the structure of facet joints of lumbar spine. It is precise and feasible to assess facet joints of lumbar spine by ultrasound. This study has important significance for the diagnosis of lumbar facet joint degeneration.
An Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer
1998-12-01
is similar to those of the study by Ivey et al. [9] in which high intensity fields were used to produce cavitation bubbles for ultrasound contrast...ft * * AD AWARD NUMBER DAMD17-94-J-4144 TITLE: ^ Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer...Examination of Ultrasound Measured Tissue Perfusion on Breast Cancer 3. REPORT TYPE AND DATES COVERED Final (1 Jun 94 - 30 Nov 98) 5. FUNDING
Roy, Sanjoy; Mohandas, Anita; Coyne, Karin; Gelhorn, Heather; Gauld, Judi; Sikirica, Vanja; Milani, Alfredo L
2012-04-01
Impairment of sexual function is a significant problem among women suffering from pelvic organ prolapse (POP). Because anatomical measures of POP do not always correspond with patients' subjective reports of their condition, patient-reported outcome measures may provide additional valuable information regarding the experiences of women who have undergone surgery. The Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12) is a validated, widely used condition-specific questionnaire focused on sexual function among patients with POP or urinary incontinence. This study aims to report sexual function outcomes as measured by PISQ-12 and to evaluate the psychometric characteristics of the questionnaire following surgical mesh implant for the treatment of POP. The PISQ-12 was used to measure sexual function, while a set of other measures, namely, Pelvic Organ Prolapse Quantification, Patient Global Impression of Change, Pelvic Floor Distress Inventory, Pelvic Floor Impact Questionnaire, and Surgical Satisfaction Questionnaire, was used for validation. Data for the study were collected from a prospective multicenter, single-arm study of surgical POP repair via the transvaginal placement of a partially absorbable mesh system. For baseline, month 3, and month 12 following POP surgery, several psychometric properties of the PISQ-12 were evaluated, including internal consistency (Cronbach's alpha), concurrent validity, discriminant validity, and responsiveness. As measured by the PISQ-12 questionnaire, statistically significant improvements were observed in the composite summary score as well as all three subscale scores at 1 year. The PISQ-12 generally demonstrated good psychometric properties including internal consistency reliability, validity, and responsiveness. The PISQ-12 items had good distributional properties at baseline, with substantial ceiling effects at follow-up visits reflecting improvements experienced by the patients. The PISQ-12 is a valid measure of sexual function in studies involving patients with POP. © 2012 International Society for Sexual Medicine.
Can Ultrasound Accurately Assess Ischiofemoral Space Dimensions? A Validation Study.
Finnoff, Jonathan T; Johnson, Adam C; Hollman, John H
2017-04-01
Ischiofemoral impingement is a potential cause of hip and buttock pain. It is evaluated commonly with magnetic resonance imaging (MRI). To our knowledge, no study previously has evaluated the ability of ultrasound to measure the ischiofemoral space (IFS) dimensions reliably. To determine whether ultrasound could accurately measure the IFS dimensions when compared with the gold standard imaging modality of MRI. A methods comparison study. Sports medicine center within a tertiary-care institution. A total of 5 male and 5 female asymptomatic adult subjects (age mean = 29.2 years, range = 23-35 years; body mass index mean = 23.5, range = 19.5-26.6) were recruited to participate in the study. Subjects were secured in a prone position on a MRI table with their hips in a neutral position. Their IFS dimensions were then acquired in a randomized order using diagnostic ultrasound and MRI. The main outcome measurements were the IFS dimensions acquired with ultrasound and MRI. The mean IFS dimensions measured with ultrasound was 29.5 mm (standard deviation [SD] 4.99 mm, standard error mean 1.12 mm), whereas those obtained with MRI were 28.25 mm (SD 5.91 mm, standard error mean 1.32 mm). The mean difference between the ultrasound and MRI measurements was 1.25 mm, which was not statistically significant (SD 3.71 mm, standard error mean 3.71 mm, 95% confidence interval -0.49 mm to 2.98 mm, t 19 = 1.506, P = .15). The Bland-Altman analysis indicated that the 95% limits of agreement between the 2 measurement was -6.0 to 8.5 mm, indicating that there was no systematic bias between the ultrasound and MRI measurements. Our findings suggest that the IFS measurements obtained with ultrasound are very similar to those obtained with MRI. Therefore, when evaluating individuals with suspected ischiofemoral impingement, one could consider using ultrasound to measure their IFS dimensions. III. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Xing, Jida; Chen, Jie
2015-06-23
In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous design, the new design reduced sensing time from 20 s to 12 s, and the sensor's average error from 3.97 mW/cm2 to 1.31 mW/cm2 respectively.
Xing, Jida; Chen, Jie
2015-01-01
In therapeutic ultrasound applications, accurate ultrasound output intensities are crucial because the physiological effects of therapeutic ultrasound are very sensitive to the intensity and duration of these applications. Although radiation force balance is a benchmark technique for measuring ultrasound intensity and power, it is costly, difficult to operate, and compromised by noise vibration. To overcome these limitations, the development of a low-cost, easy to operate, and vibration-resistant alternative device is necessary for rapid ultrasound intensity measurement. Therefore, we proposed and validated a novel two-layer thermoacoustic sensor using an artificial neural network technique to accurately measure low ultrasound intensities between 30 and 120 mW/cm2. The first layer of the sensor design is a cylindrical absorber made of plexiglass, followed by a second layer composed of polyurethane rubber with a high attenuation coefficient to absorb extra ultrasound energy. The sensor determined ultrasound intensities according to a temperature elevation induced by heat converted from incident acoustic energy. Compared with our previous one-layer sensor design, the new two-layer sensor enhanced the ultrasound absorption efficiency to provide more rapid and reliable measurements. Using a three-dimensional model in the K-wave toolbox, our simulation of the ultrasound propagation process demonstrated that the two-layer design is more efficient than the single layer design. We also integrated an artificial neural network algorithm to compensate for the large measurement offset. After obtaining multiple parameters of the sensor characteristics through calibration, the artificial neural network is built to correct temperature drifts and increase the reliability of our thermoacoustic measurements through iterative training about ten seconds. The performance of the artificial neural network method was validated through a series of experiments. Compared to our previous design, the new design reduced sensing time from 20 s to 12 s, and the sensor’s average error from 3.97 mW/cm2 to 1.31 mW/cm2 respectively. PMID:26110412
Speksnijder, L; Rousian, M; Steegers, E A P; Van Der Spek, P J; Koning, A H J; Steensma, A B
2012-07-01
Virtual reality is a novel method of visualizing ultrasound data with the perception of depth and offers possibilities for measuring non-planar structures. The levator ani hiatus has both convex and concave aspects. The aim of this study was to compare levator ani hiatus volume measurements obtained with conventional three-dimensional (3D) ultrasound and with a virtual reality measurement technique and to establish their reliability and agreement. 100 symptomatic patients visiting a tertiary pelvic floor clinic with a normal intact levator ani muscle diagnosed on translabial ultrasound were selected. Datasets were analyzed using a rendered volume with a slice thickness of 1.5 cm at the level of minimal hiatal dimensions during contraction. The levator area (in cm(2)) was measured and multiplied by 1.5 to get the levator ani hiatus volume in conventional 3D ultrasound (in cm(3)). Levator ani hiatus volume measurements were then measured semi-automatically in virtual reality (cm(3) ) using a segmentation algorithm. An intra- and interobserver analysis of reliability and agreement was performed in 20 randomly chosen patients. The mean difference between levator ani hiatus volume measurements performed using conventional 3D ultrasound and virtual reality was 0.10 (95% CI, - 0.15 to 0.35) cm(3). The intraclass correlation coefficient (ICC) comparing conventional 3D ultrasound with virtual reality measurements was > 0.96. Intra- and interobserver ICCs for conventional 3D ultrasound measurements were > 0.94 and for virtual reality measurements were > 0.97, indicating good reliability for both. Levator ani hiatus volume measurements performed using virtual reality were reliable and the results were similar to those obtained with conventional 3D ultrasonography. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Pau, Cindy T.; Keefe, Candace; Duran, Jessica
2014-01-01
Context: Although metformin is widely used to improve insulin resistance in women with polycystic ovary syndrome (PCOS), its mechanism of action is complex, with inconsistent effects on insulin sensitivity and variability in treatment response. Objective: The aim of the study was to delineate the effect of metformin on glucose and insulin parameters, determine additional treatment outcomes, and predict patients with PCOS who will respond to treatment. Design and Setting: We conducted an open-label, interventional study at an academic medical center. Subjects: Women with PCOS (n = 36) diagnosed by the National Institutes of Health criteria participated in the study. Interventions: Subjects underwent fasting blood sampling, an IV glucose tolerance test, dual-energy x-ray absorptiometry scan, transvaginal ultrasound, and measurement of human chorionic gonadotropin-stimulated androgen levels before and after 12 weeks of treatment with metformin extended release 1500 mg/d. Interval visits were performed to monitor anthropometric measurements and menstrual cycle parameters. Main Outcome Measures: Changes in glucose and insulin parameters, androgen levels, anthropometric measurements, and ovulatory menstrual cycles were evaluated. Results: Insulin sensitivity did not change despite weight loss. Glucose effectiveness (P = .002) and the acute insulin response to glucose (P = .002) increased, and basal glucose levels (P = .001) decreased after metformin treatment. T levels also decreased. Women with improved ovulatory function (61%) had lower baseline T levels and lower baseline and stimulated T and androstenedione levels after metformin treatment (all P < .05). Conclusions: Using an IV glucose tolerance test, which distinguishes improvements in glucose effectiveness and insulin sensitivity, metformin does not improve insulin sensitivity in women with PCOS but does improve glucose effectiveness. The improvement in glucose effectiveness may be partially mediated by decreased glucose levels. T levels also decreased with metformin treatment. Ovulation during metformin treatment was associated with lower baseline T levels and greater T and androstenedione decreases during treatment, but not with insulin or LH levels. Thus, the action of metformin in PCOS primarily affects glucose levels and steroidogenesis, which may be mediated by mechanisms that affect both pathways, such as inhibition of mitochondrial complex I. PMID:24606093
Determinants of emotional problems and mood disorders in women with polycystic ovary syndrome.
Głowińska, Aleksandra; Zielona-Jenek, Monika; Pawelczyk, Adam; Banaszewska, Beata E
2016-01-01
The aim of the study was to assess the prevalence and severity of emotional problems among Polish women with polycystic ovary syndrome (PCOS) and seek factors which increase the risk of their occurrence. The study group consisted of 82 women (aged 18-48), who were diagnosed with PCOS based on the Rotterdam criteria. During hospitalization, the patients completed a number of questionnaires, providing their sociodemographic data and information concerning the inconvenience of disease-associated symptoms. The question-naires included the Beck Depression Inventory (BDI), State-Trait Anxiety Inventory (STAI), and Multidimensional Self-Esteem Inventory (MSEI). Data obtained during medical examinations (blood tests, transvaginal ultrasound, height and body mass measurements) were analyzed. Out of 82 women, the results detected risk for depression in 42 (51.22%), mild depressive disorders in 32, moderate disorders in 8, and severe disorder in 2 patients. No statistically significant correlation between BDI or state anxiety and the level of the analyzed hormones, insulin resistance, or infertility treatment, was found. General self-esteem, trait anxi-ety, and marital status were associated with the occurrence of depression symptoms. BMI was associated with the level of state anxiety during hospitalization. Women with PCOS are at risk for mood and anxiety disorders. Disease-related somatic factors are not directly associated with the risk for disorder occurrence. However, severity of depression symptoms has been shown to be influenced by permanent psychological characteristics of the studied women, i.e. self-esteem, trait anxiety, and life situation (marital status). Therefore, it is recommended to include interviews about patient life situation and screening questionnaires for assessing depression into the diagnostic procedures in PCOS patients. Patients should be referred for a psychological or psychiatric consultation, if needed.
Csutak, Csaba; Badea, Radu; Bolboaca, Sorana D; Ordeanu, Claudia; Nagy, Viorica M; Fekete, Zsolt; Chiorean, Liliana; Dudea, Sorin M
2016-03-01
The aim of this study was to evaluate the use of pre and post-therapy transrectal and transvaginal ultrasonography (TRUS, TVUS) with contrast enhancement and strain elastography compared with clinical examination and magnetic resonance imaging (MRI) in the assessment of advanced stage cervical cancer. This was a prospective study, carried out over a period of nine months on subjects with advanced-stage cervical cancer (stage >/= IIB). All included patients were examined clinically and underwent abdomino-pelvic contrast enhanced MRI and multimodal US examinations (TRUS with strain elastography and contrast enhanced TVUS) at the time of diagnosis and after radiochemotherapy. Tumor size and staging at TRUS and TVUS was compared with the same data obtained by clinical examination and MRI. Pathology was the golden standard. Eight patients accomplished the inclusion criteria. In five cases the tumor stage was identical on clinical and MRI examinations. In all cases parametrial infiltration was diagnosed by all pre-treatment examinations. No significant differences were observed in tumor size between clinical, US and MRI exams either at baseline or post-therapy, in native or post-contrast examinations. The size of the tumor evaluated pre-treatment proved to be significantly smaller post-contrast in both US and MRI examinations compared with the native images. Post-therapy, no significant differences were observed on US measured tumor dimensions when comparing native with post-contrast images. Oppositely, significant smaller dimensions were observed on post-contrast MRI compared with native scans. TRUS is accurate in the estimation of pre-therapy cervical cancer dimension. The post therapy tumor evaluation is better performed with MRI. The use of intravenous contrast agents on both examinations did not improved the accuracy of tumor evaluation pre or post-therapy.
Salah, Imaduldin M
2013-02-01
This was a prospective controlled study to compare the beneficial effects of office microlaparoscopic ovarian drilling (OMLOD) under augmented local anesthesia, as a new modality treatment option, compared to those following ovarian drilling with the conventional traditional 10-mm laparoscope (laparoscopic ovarian drilling, LOD) under general anesthesia. The study included 60 anovulatory women with polycystic ovary syndrome (PCOS) who underwent OMLOD (study group) and 60 anovulatory PCOS women, in whom conventional LOD using 10-mm laparoscope under general anesthesia was performed (comparison group). Transvaginal ultrasound scan and blood sampling to measure the serum concentrations of LH, FSH, testosterone and androstenedione were performed before and after the procedure. Intraoperative and postoperative pain scores in candidate women were evaluated during the office microlaparoscopic procedure, in addition to the number of candidates who needed extra analgesia. Women undergoing OMLOD showed good intraoperative and postoperative pain scores. The number of patients discharged within 2 h after the office procedure was significantly higher, without the need for postoperative analgesia in most patients. The LH:FSH ratio, mean serum concentrations of LH and testosterone and free androgen index decreased significantly after both OMLOD and LOD. The mean ovarian volume decreased significantly (P < 0.05) a year after both OMLOD and LOD. There were no significant differences in those results after both procedures. Intra- and postoperatively augmented local anesthesia allows outpatient bilateral ovarian drilling by microlaparoscopy without general anesthesia. The high pregnancy rate, the simplicity of the method and the faster discharge time offer a new option for patients with PCOS who are resistant to clomiphene citrate. Moreover, ovarian drilling could be performed simultaneously during the routine diagnostic microlaparoscopy and integrated into the fertility workup of these patients.
Lu, Na; Wang, Yang; Su, Ying-chun; Sun, Ying-pu; Guo, Yi-hong
2015-01-01
To explore the effects of the distance between small intramural uterine fibroids (≤4 cm) and the endometrium on the outcomes of in vitro fertilization-embryo transfer (IVF-ET). We prospectively analyzed pregnancy outcomes in 117 infertile women with small intramural uterine fibroids and 117 infertile women without uterine fibroids who all underwent IVF-ET. The size and number of small intramural uterine fibroids and the shortest distance between the small intramural uterine fibroids and the endometrium were measured by transvaginal three-dimensional ultrasound. The endometrial and subendometrial blood flow parameters, implantation rate, clinical pregnancy rate, abortion rate and live birth rate were compared between the women with and without small uterine fibroids and among the different shortest distances (≤1, 1-3 and >3 mm). The effects of the size and number of small intramural uterine fibroids on IVF-ET outcomes were observed. The endometrial volume on ET day, the implantation rate and the live birth rate were significantly lower, but the abortion rate was significantly higher, in the women with small intramural uterine fibroids than in those without uterine fibroids (p < 0.05). The endometrial flow index was higher in the shortest distance ≤1-mm group than in the groups with 1-3 and >3 mm, and the implantation rate was higher in ≤1-mm group than in the >3-mm group (p < 0.05). There were no significant differences in clinical outcomes between different sizes and numbers of small intramural uterine fibroids. Small intramural uterine fibroids can affect IVF-ET outcomes. Compared with other shortest distances (1-3 and >3 mm), the shortest distance of ≤1 mm has a higher implantation rate. © 2014 S. Karger AG, Basel.
Paladini, D; Quarantelli, M; Pastore, G; Sorrentino, M; Sglavo, G; Nappi, C
2012-03-01
To review the normal and pathological development of the posterior membranous area (PMA) in the fetal brain, to define sonographic criteria with which to diagnose a Blake's pouch cyst (BPC) in the fetus and to review the ultrasound features, associations and outcome of 19 cases of BPC seen at our center over the last 5 years. We conducted a MEDLINE search using the terms 'Blake's pouch', with or without 'fourth ventricle' or '4(th) ventricle', with or without 'roof' and identified articles describing normal and/or abnormal development of the PMA, whether or not they were cited in the limited clinical literature on BPC. A description of the normal and abnormal development of BPC was derived by collating these articles. The clinical retrospective study included 19 cases of posterior fossa anomalies with a final diagnosis of BPC seen at our institution. The following variables were assessed: referral indication, gestational age at diagnosis, ultrasound and magnetic resonance imaging (MRI) findings, associated anomalies, natural history and pregnancy and neonatal outcome. A transvaginal three-dimensional (3D) ultrasound examination was performed in all cases and 15 cases underwent MRI. To confirm the diagnosis, postnatal MRI, transfontanellar ultrasound or autopsy were available in all cases. Among the 19 cases reviewed, referral indications were: suspicion of vermian abnormality in 11 (58%) cases and other non-central nervous system anomaly in eight (42%) cases. Sonographically, all cases showed the following three signs: 1) normal anatomy and size of the vermis; 2) mild/moderate anti-clockwise rotation of the vermis; 3) normal size of the cisterna magna. On 3D ultrasound, the upper wall of the cyst was clearly visible in 11/19 cases, with choroid plexuses on the superolateral margin of the cyst roof. On follow-up, the BPC had disappeared by 24-26 gestational weeks in six of the 11 cases which did not undergo termination of pregnancy (TOP), and remained unaltered until birth in the other five cases. There were associated anomalies in eight (42%) cases, in five of which this consisted of or included congenital heart disease. Karyotype was available in 14 cases, two of which were abnormal (both trisomy 21). Regarding pregnancy outcome, there were eight (42%) TOPs, two (10%) neonatal deaths and nine (48%) survivors. One neonate, in whom the BPC had disappeared by the time of birth, had obstructive hydrocephaly confirmed. Another neonate was diagnosed with Down syndrome after birth. Excluding the Down syndrome baby, neurodevelopmental outcome was normal at the time of writing in all eight cases. Based on our analysis of ultrasound features, we propose that for BPC to be diagnosed in a fetus the following three criteria should be fulfilled: 1) normal anatomy and size of the vermis; 2) mild/moderate anti-clockwise rotation of the vermis; 3) normal size of the cisterna magna. Furthermore, we found that BPC can undergo delayed fenestration at 24-26 weeks in more than 50% of cases. Finally, it seems that BPC shows a risk of association with extracardiac anomalies (heart defects in particular) and, to a lesser extent, trisomy 21. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Kim, Dohyun; Park, Sung-Ho
2016-11-01
Recently, Doppler ultrasound has been used for the measurement of pulpal blood flow in human teeth. However, the reliability of this method has not been verified. In this study, we developed a model to simulate arteriole blood flow within the dental pulp by using microfluidics. This arteriole simulator, or flow phantom, was used to determine the reliability of measurements obtained by using a Doppler ultrasound device. A microfluidic chip was fabricated by using the soft lithography technique, and blood-mimicking fluid was pumped through the channel by a microfluidic system. A Doppler ultrasound device was used for the measurement of flow velocity. The peak, mean, and minimal flow velocities obtained from the phantom and the Doppler ultrasound device were compared by using linear regression analysis and Pearson correlation coefficient. Bland-Altman analyses were performed to evaluate the velocity differences between the flow generated by the phantom and the flow measurements made with the Doppler ultrasound device. The microfluidic system was able to generate the flow profiles as intended, and the fluid flow could be monitored and controlled by the software program. There were excellent linear correlations between the peak, mean, and minimal flow velocities of the phantom and those of the Doppler ultrasound device (r = 0.94-0.996, P < .001). However, the velocities were overestimated by the Doppler ultrasound device. This phantom provides opportunities for research and education involving the Doppler ultrasound technique in dentistry. Although Doppler ultrasound can be an effective tool for the measurement of pulpal blood flow velocity, it is essential to validate and calibrate the device before clinical use. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Development of Ultrasound to Measure In-Vivo Dynamic Cervical Spine Intervertebral Disc Mechanics
2016-01-01
Award Number: W81XWH-13-1-0050 TITLE: Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics PRINCIPAL...CONTRACT NUMBER W81XWH-13-1-0050 Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics 5b. GRANT NUMBER 5c...elasticity during compression or tension. As a portable, low cost imaging modality, the dual ultrasound system quantified cervical spine IVD displacement and
Wellons, Melissa F; Bates, Gordon Wright; Schreiner, Pamela J; Siscovick, David S; Sternfeld, Barbara; Lewis, Cora E
2013-08-01
The timing of menopause is associated with multiple chronic diseases. Tools that predict this milestone have relevance for clinical and research purposes. Among infertile women, a positive relationship exists between antral follicle count (AFC) and response to controlled ovarian hyperstimulation, a marker of ovarian reserve. However, an age-independent relationship between AFC and menopause has not been demonstrated. Thus, our objective was to evaluate the relationship between AFC measured in women aged 34 to 49 years and incident natural menopause during 7 years of follow-up. The Coronary Artery Risk Development in Young Adults Study is a longitudinal community-based study (Chicago, IL; Birmingham, AL; Minneapolis, MN; and Oakland, CA) begun in 1985-1986. In 2002-2003, the Coronary Artery Risk Development in Young Adults Women's Study measured follicle-stimulating hormone (FSH) levels and performed a transvaginal ultrasound protocol that included AFC (2-10 mm follicles on both ovaries). Incident natural menopause was assessed by surveys in 2005-2006 and 2009-2010. In our sample (n = 456), the median (interquartile range) AFC and FSH level were 5 (2-9) and 7.8 (5.6-11.0) mIU/mL, respectively, at a mean (range) age of 42 (34-49) years in 2002-2003. One hundred one women reported natural menopause by 2009-2010. In Cox models, current smoking, stable menses, FSH level higher than 13 mIU/mL, and AFC of 4 or less were independently associated with incident natural menopause. Compared with AFC higher than 4, those with an AFC of 4 or less were nearly twice as likely to have undergone menopause during 7 years of follow-up (hazard ratio, 1.89; 95% CI, 1.19-3.02) after adjustment for covariates. AFC has been found to be independently associated with natural menopause during 7 years of follow-up after controlling for other markers of ovarian aging.
Wellons, Melissa F.; Bates, Gordon Wright; Schreiner, Pamela J.; Siscovick, David S.; Sternfeld, Barbara; Lewis, Cora E.
2013-01-01
Objective The timing of menopause is associated with multiple chronic diseases. Tools to predict this milestone have relevance for clinical and research purposes. Among infertile women, a positive relationship exists between antral follicle count (AFC) and response to controlled ovarian hyperstimulation, a marker of ovarian reserve. However, a relationship between AFC and menopause that is age-independent has not been demonstrated. Thus, our objective was to evaluate the relationship between AFC measured in women at ages 34–49 and incident natural menopause over 7-years of follow-up. Methods The Coronary Artery Risk Development in Young Adults (CARDIA) study is a longitudinal community-based study (Chicago, Illinois; Birmingham, Alabama; Minneapolis, Minnesota; and Oakland, California) begun in 1985–1986. In 2002–03, the CARDIA Women’s Study measured FSH levels and performed a transvaginal ultrasound protocol that included AFC (2mm–10mm follicles on both ovaries). Incident natural menopause was assessed by survey in 2005–06 and 2009–10. Results In our sample (n=456), median AFC and FSH were 5 (IQR 2–9) and 7.8 mIU/mL (IQR 5.6–11.0), respectively, at a mean age of 42 (range 34–49) in 2002–03. 101 women reported natural menopause by 2009–10. In Cox models, current smoking, stable menses, FSH>13, and AFC ≤4 were independently associated with incident natural menopause. Compared to AFC >4, those with AFC ≤4 were nearly twice as likely to have undergone menopause over 7-years of follow-up (HR 1.89, 95% CI 1.19–3.02) after adjustment for covariates. Conclusion AFC is independently associated with natural menopause over 7-years of follow-up after controlling for other markers of ovarian aging. PMID:23422869
Reid, Sara Pittenger; Kao, Chia-Ning; Pasch, Lauri; Shinkai, Kanade; Cedars, Marcelle I; Huddleston, Heather G
2017-01-01
Polycystic ovary syndrome (PCOS) is a very common disorder well known to be associated with insulin resistance and metabolic disease. Insulin resistance is likely involved in the promotion of the PCOS reproductive phenotype and may mediate some of the ovarian morphology seen in the disorder. The phenotype of each individual woman with PCOS can vary widely as can her metabolic risk. This is a cross-sectional study of patients seen in a multidisciplinary PCOS clinic at the University of California at San Francisco between 2006 and 2014. All participants underwent systematic evaluation with anthropometric measurements, comprehensive skin exam, transvaginal ultrasound and laboratory studies at the time of their initial visit to the clinic. Serum samples were stored and androgen studies were carried out on all stored samples at the University of Virginia. Logistic regression was employed to evaluate the association between ovarian volume or follicle number and metabolic parameters (fasting insulin, HOMA-IR, fasting glucose, 2 h glucose, waist circumference) and hyperandrogenism (free testosterone, total testosterone, DHEAS, acanthosis nigricans), controlling for age. Three-hundred thirteen patients seen during the study period met Rotterdam criteria for PCOS and had sufficient measurements for inclusion in our analysis. The odds ratio of elevated HOMA-IR for patients with a maximum ovarian volume >10 cc was 1.9 compared to those with a maximum ovarian volume of ≤10 cc (95% CI 1.0-3.4). The odds ratio of abnormal fasting insulin for patients with higher ovarian volume was 1.8 (95% CI 1.0-3.4) compared with those with lower ovarian volume. Follicle number was not significantly associated with any metabolic parameters. Increased ovarian volume is associated with markers of insulin resistance in PCOS. In concordance with prior studies, we did not find follicle number to be predictive of metabolic risk. Ovarian volume may serve as a useful tool to aid clinicians in their risk stratification and counseling of patients with PCOS.
Serial Change in Cervical Length for the Prediction of Emergency Cesarean Section in Placenta Previa
Shin, Jae Eun; Shin, Jong Chul; Lee, Young; Kim, Sa Jin
2016-01-01
Purpose To evaluate whether serial change in cervical length (CL) over time can be a predictor for emergency cesarean section (CS) in patients with placenta previa. Methods This was a retrospective cohort study of patients with placenta previa between January 2010 and November 2014. All women were offered serial measurement of CL by transvaginal ultrasound at 19 to 23 weeks (CL1), 24 to 28 weeks (CL2), 29 to 31 weeks (CL3), and 32 to 34 weeks (CL4). We compared clinical characteristics, serial change in CL, and outcomes between the emergency CS group (case group) and elective CS group (control group). The predictive value of change in CL for emergency CS was evaluated. Results A total of 93 women were evaluated; 31 had emergency CS due to massive vaginal bleeding. CL tended to decrease with advancing gestational age in each group. Until 29–31 weeks, CL showed no significant differences between the two groups, but after that, CL in the emergency CS group decreased abruptly, even though CL in the elective CS group continued to gradually decrease. On multivariate analysis to determine risk factors, only admissions for bleeding (odds ratio, 34.710; 95% CI, 5.239–229.973) and change in CL (odds ratio, 3.522; 95% CI, 1.210–10.253) were significantly associated with emergency CS. Analysis of the receiver operating characteristic curve showed that change in CL could be the predictor of emergency CS (area under the curve 0.734, p < 0.001), with optimal cutoff for predicting emergency cesarean delivery of 6.0 mm. Conclusions Previous admission for vaginal bleeding and change in CL are independent predictors of emergency CS in placenta previa. Women with change in CL more than 6 mm between the second and third trimester are at high risk of emergency CS in placenta previa. Single measurements of short CL at the second or third trimester do not seem to predict emergency CS. PMID:26863133
Shin, Jae Eun; Shin, Jong Chul; Lee, Young; Kim, Sa Jin
2016-01-01
To evaluate whether serial change in cervical length (CL) over time can be a predictor for emergency cesarean section (CS) in patients with placenta previa. This was a retrospective cohort study of patients with placenta previa between January 2010 and November 2014. All women were offered serial measurement of CL by transvaginal ultrasound at 19 to 23 weeks (CL1), 24 to 28 weeks (CL2), 29 to 31 weeks (CL3), and 32 to 34 weeks (CL4). We compared clinical characteristics, serial change in CL, and outcomes between the emergency CS group (case group) and elective CS group (control group). The predictive value of change in CL for emergency CS was evaluated. A total of 93 women were evaluated; 31 had emergency CS due to massive vaginal bleeding. CL tended to decrease with advancing gestational age in each group. Until 29-31 weeks, CL showed no significant differences between the two groups, but after that, CL in the emergency CS group decreased abruptly, even though CL in the elective CS group continued to gradually decrease. On multivariate analysis to determine risk factors, only admissions for bleeding (odds ratio, 34.710; 95% CI, 5.239-229.973) and change in CL (odds ratio, 3.522; 95% CI, 1.210-10.253) were significantly associated with emergency CS. Analysis of the receiver operating characteristic curve showed that change in CL could be the predictor of emergency CS (area under the curve 0.734, p < 0.001), with optimal cutoff for predicting emergency cesarean delivery of 6.0 mm. Previous admission for vaginal bleeding and change in CL are independent predictors of emergency CS in placenta previa. Women with change in CL more than 6 mm between the second and third trimester are at high risk of emergency CS in placenta previa. Single measurements of short CL at the second or third trimester do not seem to predict emergency CS.
Histologic Inflammatory Response to Transvaginal Polypropylene Mesh: A Systematic Review.
Thomas, Dominique; Demetres, Michelle; Anger, Jennifer T; Chughtai, Bilal
2018-01-01
To evaluate the inflammatory response following transvaginal implantation of polypropylene (PP) mesh. A comprehensive literature search was performed in the following databases from inception in April 2017: Ovid MEDLINE, Ovid EMBASE, and The Cochrane Library (Wiley). The studies retrieved were screened for eligibility against predefined inclusion and exclusion criteria. Twenty-three articles were included in this review. Following the implantation of PP mesh, there are immediate and local inflammatory responses. PP mesh elicits an inflammatory response that decreases over time; however, no studies documented a complete resolution. Further studies are needed to determine if there is a complete resolution of inflammation or if it persists. Copyright © 2017 Elsevier Inc. All rights reserved.
Association of polycystic ovary syndrome with cardiovascular risk factors.
Akram, Tanzeela; Hasan, Shahid; Imran, Muhammad; Karim, Asima; Arslan, Muhammad
2010-01-01
Polycystic ovary syndrome (PCOS), also clinically known as Stein-Leventhal syndrome, is an endocrine disorder that affects 5-10% of women. To evaluate the risk factors for developing early onset of cardiovascular disease (CVD) in young patients with PCOS from our local population. Case-control study. Fifty women with PCOS selected by history and transvaginal ultrasounds and 30 age-matched healthy women (controls). The case subjects and controls were further divided into two age categories comprising of equal number of subjects, of 20-29 and 30-39 years of age. The subjects underwent a detailed medical history, general physical examination, systolic (SBP) and diastolic blood pressures (DBP). Fasting blood samples were analyzed for glucose, insulin, triacylglycerides (TAG), total cholesterol, high density lipoprotein-C (HDL-C), low density lipoprotein-C (LDL-C), follicle-stimulating hormone (FSH), and luteinizing hormone (LH). Women with the PCOS had significantly higher mean arterial pressure (MAP), serum TAG, LDL-C, insulin, and LH levels when compared with the age-matched control subjects. No significant differences were observed between serum cholesterol, glucose, and FSH levels between cases and controls. However, no marked differences were observed in biochemical parameters between the two age groups of PCOS patients. Younger women with PCOS are equally at risk of developing CVD as older women.
Dijkman, A B; Mol, B W; van der Veen, F; Bossuyt, P M; Hogerzeil, H V
2000-07-01
Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.
Silvestre, Liliane; Martins, Wellington P; Candido-Dos-Reis, Francisco J
2015-07-29
This study describes the accuracy of three-dimensional power Doppler (3D-PD) angiography as secondary method for differential diagnosis of ovarian tumors. Seventy-five women scheduled for surgical removal of adnexal masses were assessed by transvaginal ultrasound. Ovarian tumors were classified by IOTA simple rules and two three-dimensional blocks were recorded. In a second step analyses, a 4 cm(3) spherical sample was obtained from the highest vascularized solid area of each stored block. Vascularization index (VI), flow index (FI) and vascularization-flow index (VFI) were calculated. The repeatability was assessed by concordance correlation coefficient (CCC) and limits of agreement (LoA), and diagnostic accuracy by area under ROC curve. IOTA simple rules classified 26 cases as benign, nine as inconclusive and 40 as malignant. There were eight false positive and no false negative. Among the masses classified as inconclusive or malignant by IOTA simple rules, the CCCs were 0.91 for VI, 0.70 for FI, and 0.86 for VFI. The areas under ROC curve were 0.82 for VI, 0.67 for FI and 0.81 for VFI. 3D-PD angiography presented considerable intraobserver variability and low accuracy for identifying false positive results of IOTA simple rules.
Vaginal foreign body mimicking cervical cancer in postmenopausal woman - case study.
Ciebiera, Michał; Słabuszewska-Jóźwiak, Aneta; Ledowicz, Witold; Jakiel, Grzegorz
2015-09-01
We present a case report of a 73-year-old, postmenopausal woman with detailed history of breast cancer and oncology treatment including tamoxifen therapy. She presented at the clinic of gynecology and obstetrics with recurrent inflammation of the urinary and genital tract and suspicion of a cervical mass. She also presented occasional abdominal complaints and malodorous vaginal discharge. These symptoms were observed in the patient for several years. Before hospitalization she received many kinds of empirical, antimicrobial treatment such as chlorquinaldol, metronidazole, nifuratel, and nystatin. She did not receive further guidance from doctors about the causes of ailments and further diagnostic and treatment capabilities. In our clinic a detailed diagnostic process including ultrasound transvaginal examination and a minisurgical procedure revealed the presence of a vaginal foreign body (which turned out to be a plastic, shampoo bottle cap) surrounded by a mass of inflamed tissue mimicking a cervical tumor. All symptoms and complaints subsided after surgical removal of the foreign body and antibacterial therapy with metronidazole and cefuroxime. Our study draws attention to the need of thorough gynecological care including prophylaxis, especially in the case of complaints of an intimate nature. Even trivial, frequently occurring disorders can be dangerous and require proper and responsible doctor's supervision and management through the healing process.
Vaginal foreign body mimicking cervical cancer in postmenopausal woman – case study
Słabuszewska-Jóźwiak, Aneta; Ledowicz, Witold; Jakiel, Grzegorz
2015-01-01
We present a case report of a 73-year-old, postmenopausal woman with detailed history of breast cancer and oncology treatment including tamoxifen therapy. She presented at the clinic of gynecology and obstetrics with recurrent inflammation of the urinary and genital tract and suspicion of a cervical mass. She also presented occasional abdominal complaints and malodorous vaginal discharge. These symptoms were observed in the patient for several years. Before hospitalization she received many kinds of empirical, antimicrobial treatment such as chlorquinaldol, metronidazole, nifuratel, and nystatin. She did not receive further guidance from doctors about the causes of ailments and further diagnostic and treatment capabilities. In our clinic a detailed diagnostic process including ultrasound transvaginal examination and a minisurgical procedure revealed the presence of a vaginal foreign body (which turned out to be a plastic, shampoo bottle cap) surrounded by a mass of inflamed tissue mimicking a cervical tumor. All symptoms and complaints subsided after surgical removal of the foreign body and antibacterial therapy with metronidazole and cefuroxime. Our study draws attention to the need of thorough gynecological care including prophylaxis, especially in the case of complaints of an intimate nature. Even trivial, frequently occurring disorders can be dangerous and require proper and responsible doctor's supervision and management through the healing process. PMID:26528112
Tower, Amanda M; Frishman, Gary N
2013-01-01
The gynecologic sequelae due to deficient uterine scar healing after cesarean section are only recently being identified and described. These include conditions such as abnormal bleeding, pelvic pain, infertility, and cesarean scar ectopic pregnancy, as well as a potentially higher risk of complications and difficulties during gynecologic procedures such as uterine evacuation, hysterectomy, endometrial ablation, and insertion of an intrauterine device. The proposed mechanism of abnormal uterine bleeding is a pouch or "isthmocele" in the lower uterine segment that causes delayed menstrual bleeding. The prevalence of symptomatic or clinically relevant cesarean scar defects (CSDs) ranges from 19.4% to 88%. Possible risk factors for CSD include number of cesarean sections, uterine position, labor before cesarean section, and surgical technique used to close the uterine incision. There are no accepted guidelines for the diagnostic criteria of CSD. We propose that a CSD be defined on transvaginal ultrasound or saline infusion sonohysterography as a triangular hypoechoic defect in the myometrium at the site of the previous hysterotomy. We also propose a classification system to aid in standardized classification for future research. Surgical techniques for repair of CSD include laparoscopic excision, resectoscopic treatment, vaginal revision, and endometrial ablation. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.
Abnormal uterine bleeding in perimenopause.
Goldstein, S R; Lumsden, M A
2017-10-01
Abnormal uterine bleeding is one of the commonest presenting complaints encountered in a gynecologist's office or primary-care setting. The wider availability of diagnostic tools has allowed prompt diagnosis and treatment of an increasing number of menstrual disorders in an office setting. This White Paper reviews the advantages and disadvantages of transvaginal ultrasound, blind endometrial sampling and diagnostic hysteroscopy. Once a proper diagnosis has been established, appropriate therapy may be embarked upon. Fortunately, only a minority of such patients will have premalignant or malignant disease. When bleeding is sufficient to cause severe anemia or even hypovolemia, prompt intervention is called for. In most of the cases, however, the abnormal uterine bleeding will be disquieting to the patient and significantly affect her 'quality of life'. Sometimes, reassurance and expectant management will be sufficient in such patients. Overall, however, in cases of benign disease, some intervention will be required. The use of oral contraceptive pills especially those with a short hormone-free interval, the insertion of the levonorgestrel intrauterine system, the incorporation of newer medical therapies including antifibrinolytic drugs and selective progesterone receptor modulators and minimally invasive treatments have made outpatient therapy increasingly effective. For others, operative hysteroscopy and endometrial ablation are proven therapeutic tools to provide both long- and short-term relief of abnormal uterine bleeding, thus avoiding, or deferring, hysterectomy.
What the physician needs to know about Lynch syndrome: an update.
Lynch, Henry T; Lynch, Jane F
2005-04-01
The Lynch syndrome (hereditary nonpolyposis colorectal cancer [HNPCC]), is the most common form of hereditary colorectal cancer (CRC), accounting for 2% to 7% of all CRC cases. The next most common hereditary CRC syndrome is familial adenomatous polyposis (FAP), which accounts for less than 1% of all CRC. Lynch syndrome is of crucial clinical importance due to the fact that it predicts the lifetime risk for CRC and a litany of extra-CRC cancers (of the endometrium, ovary, stomach, small bowel, hepatobiliary tract, upper uroepithelial tract, and brain) through assessment of a well-orchestrated family history. A Lynch syndrome diagnosis is almost certain when a mutation in a mismatch repair gene--most commonly MSH2, MLHI, or, to a lesser degree, MSH6--is identified. Once diagnosed, the potential for significant reduction in cancer-related morbidity and mortality through highly targeted surveillance may be profound. Particularly important is colonoscopy initiated at an early age (ie, 25 years) and repeated annually due to accelerated carcinogenesis. In women, endometrial aspiration biopsy and transvaginal ultrasound are important given the extraordinarily high risk for endometrial and ovarian carcinoma. These cancer control strategies have a major impact on at-risk family members once they have been counseled and educated thoroughly about Lynch syndrome's natural history and their own hereditary cancer risk.
Adenomyosis: a life-cycle approach.
Benagiano, Giuseppe; Brosens, Ivo; Habiba, Marwan
2015-03-01
The life-cycle approach to endometriosis highlighted unexpected features of the condition; the same approach was therefore applied to gain insight into the clinical features of adenomyosis and to draw a comparison with endometriosis. This is possible today thanks to new imaging techniques enabling non-invasive diagnosis of adenomyosis. The specificity and sensitivity of magnetic resonance imaging and transvaginal ultrasound remain uncertain. Unlike endometriosis, little information is available on the presence of classic adenomyosis in adolescents, except for rare cystic forms that may not represent the true disease. Adenomyosis is most likely to affect adult women, although most reported incidences are still based on post-hysterectomy studies, and are affected by diligence in histopathologic diagnosis and the adopted cut-off point. The traditionally accepted associations of adult adenomyosis, such as multiparity, a link to infertility and its effect on pregnancy are uncertain. Active adenomyosis has been found in pre- and peri-menopausal women and in postmenopausal women receiving tamoxifen. In conclusion, major diagnostic limitations and the systematic bias of hysterectomy make it difficult to draw firm conclusions from existing evidence. In addition, no information is available on the natural history of adenomyosis and no study has systematically evaluated its existence in adolescents. Copyright © 2014 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Yoon, Sangpil; Aglyamov, Salavat; Karpiouk, Andrei; Emelianov, Stanislav
2012-01-01
A high pulse repetition frequency ultrasound system for ex vivo measurement of mechanical properties of animal crystalline lens was developed and validated. We measured the bulk displacement of laser-induced microbubbles created at different positions within the lens using nanosecond laser pulses. An impulsive acoustic radiation force was applied to the microbubble, and spatio-temporal measurements of the microbubble displacement were assessed using a custom-made high pulse repetition frequency ultrasound system consisting of two 25 MHz focused ultrasound transducers. One of these transducers was used to emit a train of ultrasound pulses and another transducer was used to receive the ultrasound echoes reflected from the microbubble. The developed system was operating at 1 MHz pulse repetition frequency. Based on measured motion of the microbubble, the Young’s moduli of surrounding tissue were reconstructed and the values were compared with those measured using indentation test. Measured values of Young’s moduli of 4 bovine lenses ranged from 2.6±0.1 to 26±1.4 kPa and there was good agreement between the two methods. Therefore, our studies, utilizing the high pulse repetition frequency ultrasound system, suggest that the developed approach can be used to assess the mechanical properties of ex vivo crystalline lenses. Furthermore, the potential of the presented approach for in vivo measurements is discussed. PMID:22797709
NASA Astrophysics Data System (ADS)
Chandran, R. Sriram; Sarkar, Saikat; Kanhirodan, Rajan; Roy, Debasish; Vasu, Ram Mohan
2014-07-01
We demonstrate diffusing-wave spectroscopy (DWS) in a localized region of a viscoelastically inhomogeneous object by measurement of the intensity autocorrelation [g2(τ)] that captures only the decay introduced by the temperature-induced Brownian motion in the region. The region is roughly specified by the focal volume of an ultrasound transducer which introduces region specific mechanical vibration owing to insonification. Essential characteristics of the localized non-Markovian dynamics are contained in the decay of the modulation depth [M(τ)], introduced by the ultrasound forcing in the focal volume selected, on g2(τ). The modulation depth M (τi) at any delay time τi can be measured by short-time Fourier transform of g2(τ) and measurement of the magnitude of the spectrum at the ultrasound drive frequency. By following the established theoretical framework of DWS, we are able to connect the decay in M (τ) to the mean-squared displacement (MSD) of scattering centers and the MSD to G*(ω), the complex viscoelastic spectrum. A two-region composite polyvinyl alcohol phantom with different viscoelastic properties is selected for demonstrating local DWS-based recovery of G*(ω) corresponding to these regions from the measured region specific M (τi)vsτi. The ultrasound-assisted measurement of MSD is verified by simulating, using a generalized Langevin equation (GLE), the dynamics of the particles in the region selected as well as by the usual DWS experiment without the ultrasound. It is shown that whereas the MSD obtained by solving the GLE without the ultrasound forcing agreed with its experimental counterpart covering small and large values of τ, the match was good only in the initial transients in regard to experimental measurements with ultrasound.
Selected Adnexal Cystic Masses in Postmenopausal Women Can be Safely Managed by Laparoscopy
Lee, Jeong-Won; Kim, Chul Jung; Lee, Ji Eun; Lee, Sun-Joo; Kim, Byoung-Gie; Lee, Je-Ho; Bae, Duk-Soo
2005-01-01
The aim of this study was to assess the efficacy and safety of laparoscopic treatment for adnexal cystic masses that were predicted to be benign in postmenopausal women. Postmenopausal women found to have an adnexal cystic mass were retrospectively evaluated with transvaginal ultrasonography, and serum CA-125 levels. The selection criteria were adnexal cystic masses greater than 3 cm but less than 10 cm, the masses were in the benign range (4-8) of Sassone's scoring system for transvaginal ultrasonography, and the patients had serum CA-125 levels less than 65 IU/mL. Two hundred nineteen women fulfilled the criteria and underwent operative laparoscopy. Almost all the masses (99.5%) were accurately predicted to be benign except for one borderline ovarian tumor. Two hundreds thirteen (97.3%) women were successfully managed by operative laparoscopy and six (2.7%) required laparotomy. For the patients managed by laparoscopy, the mean operative time was 51.3 min; the mean hospital stay was 2.5 days. There was no significant morbidity and surgery-related mortality. The combination of the Sassone's scoring system for transvaginal ultrasonography and serum CA-125 level can accurately predict benign cystic masses, and operative laparoscopy is technically feasible and safe for the management of adnexal mass in postmenopausal women. PMID:15953871
The effect of G-CSF on infertile women undergoing IVF treatment: A meta-analysis.
Li, Jie; Mo, Sien; Chen, Yang
2017-08-01
Evidence for the effect of granulocyte colony stimulating factor (G-CSF) on infertile women undergoing in vitro fertilization (IVF) remains inconsistent. This study aimed to evaluate the effectiveness of G-CSF on infertile women undergoing IVF. PubMed and EMBASE databases were searched before August 2016. Comparing the transvaginal perfusion of G-CSF and placebo or no treatment, the available studies were considered. The pooled risk ratio (RR) with 95% confidence intervals (CIs) was used in the analysis and six studies were included. Transvaginal perfusion of G-CSF was significantly associated with a higher clinical pregnancy rate versus the placebo (RR=1.563, 95%CI: 1.122, 2.176), especially for the Asian population. Among patients with a thin endometrium or repeated IVF failure, the implantation and biochemical pregnancy rates were also significantly increased in patients with the use of G-CSF (implantation rate: RR = 1.887, 95% CI: 1.256, 2.833; biochemical pregnancy rate: RR = 2.385, 95% CI: 1.414, 4.023). However, no statistical significance in increasing endometrial thickness was detected. Transvaginal perfusion of G-CSF for infertile women may play a critical role in assisting human reproduction, especially for patients with a thin endometrium or repeated IVF failure in the Asian population.
Fertility outcome following transvaginal cervicoisthmic cerclage using a polypropylene sling.
Deffieux, Xavier; Faivre, Erika; Senat, Marie Victoire; Fuchs, Florent; Gervaise, Amélie; Fernandez, Hervé
2010-04-01
To report fertility and pregnancy outcomes following transvaginal cervicoisthmic cerclage with a polypropylene sling during a previous pregnancy. A continuous series of 57 women who underwent prophylactic cervicoisthmic cerclage during a previous (reference) pregnancy were enrolled. Telephone interviews were carried out to evaluate each patient's subsequent fertility. Among the 57 women interviewed, 8 had an inadequate follow-up, 13 women were lost to follow-up, 1 woman required a hemostatic hysterectomy, and 2 women required removal of the sling. Nineteen women did not desire a subsequent pregnancy. Of the 14 women who did desire a subsequent pregnancy, 1 woman had previously known tubal infertility. Of the 13 remaining women, 7 subsequently became pregnant. One woman had a spontaneous abortion (11 weeks of pregnancy); 1 woman delivered at 22 weeks of pregnancy, after a spontaneous premature membrane rupture; 1 woman had a cesarean delivery at 25 weeks of pregnancy; and 4 patients had a cesarean delivery after 37 weeks of pregnancy. Median duration of the 4 subsequent pregnancies at delivery was 37 weeks (interquartile range [IQR], 37-38 weeks). Median birth weight was 3040 g (IQR, 2500-3250 g). Subsequent pregnancy is possible after transvaginal cervicoisthmic cerclage using a synthetic sling. Copyright 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Culligan, Patrick J; Littman, Paul M; Salamon, Charbel G; Priestley, Jennifer L; Shariati, Amir
2010-11-01
We sought to track objective and subjective outcomes ≥1 year after transvaginal mesh system to correct prolapse. This was a retrospective cohort study of 120 women who received a transvaginal mesh procedure (Avaulta Solo, CR Bard Inc, Covington, GA). Outcomes were pelvic organ prolapse quantification values; Pelvic Floor Distress Inventory, Short Form 20/Pelvic Floor Impact Questionnaire, Short Form 7 scores; and a surgical satisfaction survey. "Surgical failure" was defined as pelvic organ prolapse quantification point >0, and/or any reports of vaginal bulge. Of 120 patients, 116 (97%) were followed up for a mean of 14.4 months (range, 12-30). In all, 74 patients had only anterior mesh, 21 only posterior mesh, and 21 both meshes. Surgical cure rate was 81%. Surgical failure was more common if preoperative point C ≥+2 (35% vs 16%; P = .04). Mesh erosion and de novo pain occurred in 11.7% and 3.3%, respectively. Pelvic Floor Distress Inventory, Short Form 20/Pelvic Floor Impact Questionnaire, Short Form 7 scores improved (P < .01). Objective and subjective improvements occurred at ≥1 year, yet failure rates were high when preoperative point C was ≥+2. Copyright © 2010 Mosby, Inc. All rights reserved.
Multimedia systems in ultrasound image boundary detection and measurements
NASA Astrophysics Data System (ADS)
Pathak, Sayan D.; Chalana, Vikram; Kim, Yongmin
1997-05-01
Ultrasound as a medical imaging modality offers the clinician a real-time of the anatomy of the internal organs/tissues, their movement, and flow noninvasively. One of the applications of ultrasound is to monitor fetal growth by measuring biparietal diameter (BPD) and head circumference (HC). We have been working on automatic detection of fetal head boundaries in ultrasound images. These detected boundaries are used to measure BPD and HC. The boundary detection algorithm is based on active contour models and takes 32 seconds on an external high-end workstation, SUN SparcStation 20/71. Our goal has been to make this tool available within an ultrasound machine and at the same time significantly improve its performance utilizing multimedia technology. With the advent of high- performance programmable digital signal processors (DSP), the software solution within an ultrasound machine instead of the traditional hardwired approach or requiring an external computer is now possible. We have integrated our boundary detection algorithm into a programmable ultrasound image processor (PUIP) that fits into a commercial ultrasound machine. The PUIP provides both the high computing power and flexibility needed to support computationally-intensive image processing algorithms within an ultrasound machine. According to our data analysis, BPD/HC measurements made on PUIP lie within the interobserver variability. Hence, the errors in the automated BPD/HC measurements using the algorithm are on the same order as the average interobserver differences. On PUIP, it takes 360 ms to measure the values of BPD/HC on one head image. When processing multiple head images in sequence, it takes 185 ms per image, thus enabling 5.4 BPD/HC measurements per second. Reduction in the overall execution time from 32 seconds to a fraction of a second and making this multimedia system available within an ultrasound machine will help this image processing algorithm and other computer-intensive imaging applications become a practical tool for the sonographers in the feature.
Ultrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness
Brandenburg, Joline E.; Eby, Sarah F.; Song, Pengfei; Zhao, Heng; Brault, Jeffrey S.; Chen, Shigao; An, Kai-Nan
2014-01-01
The use of brightness-mode ultrasound and Doppler ultrasound in physical medicine and rehabilitation has increased dramatically. The continuing evolution of ultrasound technology has also produced ultrasound elastography, a cutting-edge technology that can directly measure the mechanical properties of tissue, including muscle stiffness. Its real-time and direct measurements of muscle stiffness can aid the diagnosis and rehabilitation of acute musculoskeletal injuries and chronic myofascial pain. It can also help monitor outcomes of interventions affecting muscle in neuromuscular and musculoskeletal diseases, and it can better inform the functional prognosis. This technology has implications for even broader use of ultrasound in physical medicine and rehabilitation practice, but more knowledge about its uses and limitations is essential to its appropriate clinical implementation. In this review, we describe different ultrasound elastography techniques for studying muscle stiffness, including strain elastography, acoustic radiation force impulse imaging, and shear-wave elastography. We discuss the basic principles of these techniques, including the strengths and limitations of their measurement capabilities. We review the current muscle research, discuss physiatric clinical applications of these techniques, and note directions for future research. PMID:25064780
Wear, Keith A; Nagaraja, Srinidhi; Dreher, Maureen L; Sadoughi, Saghi; Zhu, Shan; Keaveny, Tony M
2017-10-01
Clinical bone sonometers applied at the calcaneus measure broadband ultrasound attenuation and speed of sound. However, the relation of ultrasound measurements to bone strength is not well-characterized. Addressing this issue, we assessed the extent to which ultrasonic measurements convey in vitro mechanical properties in 25 human calcaneal cancellous bone specimens (approximately 2×4×2cm). Normalized broadband ultrasound attenuation, speed of sound, and broadband ultrasound backscatter were measured with 500kHz transducers. To assess mechanical properties, non-linear finite element analysis, based on micro-computed tomography images (34-micron cubic voxel), was used to estimate apparent elastic modulus, overall specimen stiffness, and apparent yield stress, with models typically having approximately 25-30 million elements. We found that ultrasound parameters were correlated with mechanical properties with R=0.70-0.82 (p<0.001). Multiple regression analysis indicated that ultrasound measurements provide additional information regarding mechanical properties beyond that provided by bone quantity alone (p≤0.05). Adding ultrasound variables to linear regression models based on bone quantity improved adjusted squared correlation coefficients from 0.65 to 0.77 (stiffness), 0.76 to 0.81 (apparent modulus), and 0.67 to 0.73 (yield stress). These results indicate that ultrasound can provide complementary (to bone quantity) information regarding mechanical behavior of cancellous bone. Published by Elsevier Inc.
On the reproducibility of expert-operated and robotic ultrasound acquisitions.
Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir
2017-06-01
We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.
Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å
2016-06-01
To study the correlation between palpation, perineometry and transperineal ultrasound for assessment of pelvic floor muscle contraction and to define a contraction scale for ultrasound measurements. This was a cross-sectional study of 608 women examined with palpation of pelvic floor muscle contraction, using the Modified Oxford Scale, and measurement of the vaginal squeeze pressure with a vaginal balloon connected to a fiber-optic microtip transducer (perineometry). Transperineal ultrasound was used for measurements of levator hiatal area and anteroposterior (AP) diameter in the plane of minimal hiatal dimensions, at rest and on contraction. The pelvic floor muscle contraction was expressed as the percentage difference between values at rest and on contraction. Spearman's rank was used to test for correlation between the different methods of assessment. Significant correlations were found between all assessment methods (P < 0.001). Palpation correlated with perineometry (rs = 0.74) and with proportional change in hiatal area (rs = 0.67) and AP diameter (rs = 0.69) on ultrasound. Perineometry correlated with proportional change in hiatal area (rs = 0.60) and AP diameter (rs = 0.66) on ultrasound. We defined a contraction scale based on the proportional change in AP diameter. In this population, a change in AP diameter of < 7% corresponded to absence of contractions, 7-18% corresponded to weak contractions, 18-35% corresponded to normal contractions and > 35% corresponded to strong contractions. We found moderate to strong correlation between ultrasound measurements, palpation and perineometry for assessing pelvic floor muscle contraction. The proportional change in levator hiatal AP diameter was the ultrasound measurement with strongest correlation to palpation and perineometry and formed the basis for the contraction scale for ultrasound measurements. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Yoon, Sangpil; Aglyamov, Salavat; Karpiouk, Andrei; Emelianov, Stanislav
2012-08-07
A high pulse repetition frequency ultrasound system for an ex vivo measurement of mechanical properties of an animal crystalline lens was developed and validated. We measured the bulk displacement of laser-induced microbubbles created at different positions within the lens using nanosecond laser pulses. An impulsive acoustic radiation force was applied to the microbubble, and spatio-temporal measurements of the microbubble displacement were assessed using a custom-made high pulse repetition frequency ultrasound system consisting of two 25 MHz focused ultrasound transducers. One of these transducers was used to emit a train of ultrasound pulses and another transducer was used to receive the ultrasound echoes reflected from the microbubble. The developed system was operating at 1 MHz pulse repetition frequency. Based on the measured motion of the microbubble, Young's moduli of surrounding tissue were reconstructed and the values were compared with those measured using the indentation test. Measured values of Young's moduli of four bovine lenses ranged from 2.6 ± 0.1 to 26 ± 1.4 kPa, and there was good agreement between the two methods. Therefore, our studies, utilizing the high pulse repetition frequency ultrasound system, suggest that the developed approach can be used to assess the mechanical properties of ex vivo crystalline lenses. Furthermore, the potential of the presented approach for in vivo measurements is discussed.
Validation of Greyscale-Based Quantitative Ultrasound in Manual Wheelchair Users
Collinger, Jennifer L.; Fullerton, Bradley; Impink, Bradley G.; Koontz, Alicia M.; Boninger, Michael L.
2010-01-01
Objective The primary aim of this study is to establish the validity of greyscale-based quantitative ultrasound (QUS) measures of the biceps and supraspinatus tendons. Design Nine QUS measures of the biceps and supraspinatus tendons were computed from ultrasound images collected from sixty-seven manual wheelchair users. Shoulder pathology was measured using questionnaires, physical examination maneuvers, and a clinical ultrasound grading scale. Results Increased age, duration of wheelchair use, and body mass correlated with a darker, more homogenous tendon appearance. Subjects with pain during physical examination tests for biceps tenderness and acromioclavicular joint tenderness exhibited significantly different supraspinatus QUS values. Even when controlling for tendon depth, QUS measures of the biceps tendon differed significantly between subjects with healthy tendons, mild tendinosis, and severe tendinosis. Clinical grading of supraspinatus tendon health was correlated with QUS measures of the supraspinatus tendon. Conclusions Quantitative ultrasound is valid method to quantify tendinopathy and may allow for early detection of tendinosis. Manual wheelchair users are at a high risk for developing shoulder tendon pathology and may benefit from quantitative ultrasound-based research that focuses on identifying interventions designed to reduce this risk. PMID:20407304
Sorensen, Mathew D; Teichman, Joel M H; Bailey, Michael R
2009-07-01
Proof-of-principle in vitro experiments evaluated a prototype ultrasound technology to size kidney stone fragments. Nineteen human stones were measured using manual calipers. A 10-MHz, 1/8'' (10F) ultrasound transducer probe pinged each stone on a kidney tissue phantom submerged in water using two methods. In Method 1, the instrument was aligned such that the ultrasound pulse traveled through the stone. In Method 2, the instrument was aligned partially over the stone such that the ultrasound pulse traveled through water. For Method 1, the correlation between caliper- and ultrasound-determined stone size was r(2) = 0.71 (P < 0.0001). All but two stone measurements were accurate and precise to within 1 mm. For Method 2, the correlation was r(2) = 0.99 (P < 0.0001), and measurements were accurate and precise to within 0.25 mm. The prototype technology and either method measured stone size with good accuracy and precision. This technology may be possible to incorporate into ureteroscopy.
An ultrasound wearable system for the monitoring and acceleration of fracture healing in long bones.
Protopappas, Vasilios C; Baga, Dina A; Fotiadis, Dimitrios I; Likas, Aristidis C; Papachristos, Athanasios A; Malizos, Konstantinos N
2005-09-01
An ultrasound wearable system for remote monitoring and acceleration of the healing process in fractured long bones is presented. The so-called USBone system consists of a pair of ultrasound transducers, implanted into the fracture region, a wearable device and a centralized unit. The wearable device is responsible to carry out ultrasound measurements using the axial-transmission technique and initiate therapy sessions of low-intensity pulsed ultrasound. The acquired measurements and other data are wirelessly transferred from the patient-site to the centralized unit, which is located in a clinical setting. The evaluation of the system on an animal tibial osteotomy model is also presented. A dataset was constructed for monitoring purposes consisting of serial ultrasound measurements, follow-up radiographs, quantitative computed tomography-based densitometry and biomechanical data. The animal study demonstrated the ability of the system to collect ultrasound measurements in an effective and reliable fashion and participating orthopaedic surgeons accepted the system for future clinical application. Analysis of the acquired measurements showed that the pattern of evolution of the ultrasound velocity through healing bones over the postoperative period monitors a dynamic healing process. Furthermore, the ultrasound velocity of radiographically healed bones returns to 80% of the intact bone value, whereas the correlation coefficient of the velocity with the material and mechanical properties of the healing bone ranges from 0.699 to 0.814. The USBone system constitutes the first telemedicine system for the out-hospital management of patients sustained open fractures and treated with external fixation devices.
Katorza, E; Bertucci, E; Perlman, S; Taschini, S; Ber, R; Gilboa, Y; Mazza, V; Achiron, R
2016-07-01
Normal biometry of the fetal posterior fossa rules out most major anomalies of the cerebellum and vermis. Our aim was to provide new reference data of the fetal vermis in 4 biometric parameters by using 3 imaging modalities, 2D ultrasound, 3D ultrasound, and MR imaging, and to assess the relation among these modalities. A retrospective study was conducted between June 2011 and June 2013. Three different imaging modalities were used to measure vermis biometry: 2D ultrasound, 3D ultrasound, and MR imaging. The vermian parameters evaluated were the maximum superoinferior diameter, maximum anteroposterior diameter, the perimeter, and the surface area. Statistical analysis was performed to calculate centiles for gestational age and to assess the agreement among the 3 imaging modalities. The number of fetuses in the study group was 193, 172, and 151 for 2D ultrasound, 3D ultrasound, and MR imaging, respectively. The mean and median gestational ages were 29.1 weeks, 29.5 weeks (range, 21-35 weeks); 28.2 weeks, 29.05 weeks (range, 21-35 weeks); and 32.1 weeks, 32.6 weeks (range, 27-35 weeks) for 2D ultrasound, 3D ultrasound, and MR imaging, respectively. In all 3 modalities, the biometric measurements of the vermis have shown a linear growth with gestational age. For all 4 biometric parameters, the lowest results were those measured by MR imaging, while the highest results were measured by 3D ultrasound. The inter- and intraobserver agreement was excellent for all measures and all imaging modalities. Limits of agreement were considered acceptable for clinical purposes for all parameters, with excellent or substantial agreement defined by the intraclass correlation coefficient. Imaging technique-specific reference data should be used for the assessment of the fetal vermis in pregnancy. © 2016 by American Journal of Neuroradiology.
Measurement of corneal tangent modulus using ultrasound indentation.
Wang, Li-Ke; Huang, Yan-Ping; Tian, Lei; Kee, Chea-Su; Zheng, Yong-Ping
2016-09-01
Biomechanical properties are potential information for the diagnosis of corneal pathologies. An ultrasound indentation probe consisting of a load cell and a miniature ultrasound transducer as indenter was developed to detect the force-indentation relationship of the cornea. The key idea was to utilize the ultrasound transducer to compress the cornea and to ultrasonically measure the corneal deformation with the eyeball overall displacement compensated. Twelve corneal silicone phantoms were fabricated with different stiffness for the validation of measurement with reference to an extension test. In addition, fifteen fresh porcine eyes were measured by the developed system in vitro. The tangent moduli of the corneal phantoms calculated using the ultrasound indentation data agreed well with the results from the tensile test of the corresponding phantom strips (R(2)=0.96). The mean tangent moduli of the porcine corneas measured by the proposed method were 0.089±0.026MPa at intraocular pressure (IOP) of 15mmHg and 0.220±0.053MPa at IOP of 30mmHg, respectively. The coefficient of variation (CV) and intraclass correlation coefficient (ICC) of tangent modulus were 14.4% and 0.765 at 15mmHg, and 8.6% and 0.870 at 30mmHg, respectively. The preliminary study showed that ultrasound indentation could be applied to the measurement of corneal tangent modulus with good repeatability and improved measurement accuracy compared to conventional surface displacement-based measurement method. The ultrasound indentation can be a potential tool for the corneal biomechanical properties measurement in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.
An ergonomic, instrumented ultrasound probe for 6-axis force/torque measurement.
Gilbertson, Matthew W; Anthony, Brian W
2013-01-01
An ergonomic, instrumented ultrasound probe has been developed for medical imaging applications. The device, which fits compactly in the hand of sonographers and permits rapid attachment & removal of the ultrasound probe, measures ultrasound probe-to-patient contact forces and torques in all six axes. The device was used to measure contact forces and torques applied by ten professional sonographers on five patients during thirty-six abdominal exams. Of the three contact forces, those applied along the probe axis were found to be largest, averaging 7.0N. Measurement noise was quantified for each axis, and found to be small compared with the axial force. Understanding the range of forces applied during ultrasound imaging enables the design of more accurate robotic imaging systems and could also improve understanding of the correlation between contact force and sonographer fatigue and injury.
Project for the National Program of Early Diagnosis of Endometrial Cancer Part I.
Bohîlțea, R E; Ancăr, V; Cirstoiu, M M; Rădoi, V; Bohîlțea, L C; Furtunescu, F
2015-01-01
Endometrial cancer recorded a peak incidence in ages 60-64 years in Romania, reaching in 2013 the average value of 8.06/ 100,000 women, and 15.97/ 100,000 women within the highest risk age range, having in recent years an increasing trend, being higher in urban than in rural population. Annually, approximately 800 new cases are registered in our country. The estimated lifetime risk of a woman to develop endometrial cancer is of about 1,03%. Based on an abnormal uterine bleeding, 35% of the endometrial cancers are diagnosed in an advanced stage of the disease, with significantly diminished lifetime expectancy. Drafting a national program for the early diagnosis of endometrial cancer. We proposed a standardization of the diagnostic steps and focused on 4 key elements for the early diagnosis of endometrial cancer: investigation of abnormal uterine bleeding occurring in pre/ post-menopausal women, investigating features/ anomalies of cervical cytology examination, diagnosis, treatment and proper monitoring of precursor endometrial lesions or cancer associated endometrial lesions and screening high risk populations (Lynch syndrome, Cowden syndrome). Improving medical practice based on diagnostic algorithms addresses the four risk groups, by improving information system reporting and record keeping. Improving addressability cases by increasing the health education of the population will increase the rate of diagnosis of endometrial cancer in the early stages of the disease. ACOG = American Society of Obstetricians and Gynecologists, ASCCP = American Society for Colposcopy and Cervical Pathology, PATT = Partial Activated Thromboplastin Time, BRCA = Breast Cancer Gene, CT = Computerized Tomography, IFGO = International Federation of Gynecology and Obstetrics, HLG = Hemoleucogram, HNPCC = Hereditary Nonpolyposis Colorectal Cancer (Lynch syndrome), IHC = Immunohistochemistry, BMI = Body Mass Index, INR = International Normalized Ratio, MSI = Microsatellites instability, MSI-H/ MSI-L = high (positive test)/ low (negative test) microsatellites instability, WHO = World Health Organization, PCR = Polymerase chain reaction, MRI = Magnetic Resonance Imaging, SGO = Society of Gynecologic Oncologists, SHG = Sonohysterography, SRU = Society of Radiologists in Ultrasound, TQ = Time Quick, BT = Bleeding Time, TVUS = Transvaginal ultrasound, USPIO = Ultrasmall superparamagnetic iron oxide.
Testa, Antonia Carla; Ferrandina, Gabriella; Fruscella, Erika; Van Holsbeke, Caroline; Ferrazzi, Enrico; Leone, Francesco P G; Arduini, Domenico; Exacoustos, Caterina; Bokor, Daniela; Scambia, Giovanni; Timmerman, Dirk
2005-09-01
The purpose of this study was to evaluate the efficacy of a new contrast-dedicated ultrasound technology, contrast-tuned imaging (CnTI), implemented on an endovaginal probe and using the second-generation contrast agent SonoVue (Bracco International BV, Amsterdam, the Netherlands), compared with the standard ultrasound examination in different gynecologic diseases. Eighty-nine patients were enrolled in the study in 4 different clinical centers. The study included 40 patients with uncertain pelvic adnexal masses, 10 patients with pelvic masses indicative of recurrences of gynecologic tumors, 26 patients with uterine pathologic features, and 13 patients with cervical lesions. Application of CnTI technology after the SonoVue injection gave a picture of the intralesional microvascularization dramatically different from that obtained during color Doppler examination. Of the 40 pelvic masses, 15 (37.5%) were considered benign and 25 (62.5%) were considered malignant at B-mode and color Doppler examinations. Contrast-enhanced sonography showed no intralesional contrast perfusion in 11 (73%) of 15 cases, and all these were benign at final diagnosis. Of the 4 (27%) cases that had perfusion, 2 were malignant. Conversely, of the 25 cases with positive findings at color Doppler examination and therefore expected to show the appearance of contrast tissue-filling morphologic characteristics, 13 (52%) were malignant at final diagnosis. For evaluation of uterine pathologic features, the CnTI-SonoVue technology did not appear to be superior to the B-mode and color Doppler examinations; however, for the evaluation of cervical cancer, CnTI-SonoVue technology revealed a better definition of the margins of the neoplastic lesions in 4 (40%) of 10 cases. In the evaluation of uncertain pelvic masses, the CnTI technology led to an improvement in the ability of the practitioner to differentiate benign from malignant adnexal lesions.
Bamberg, Christian; Dudenhausen, Joachim W; Bujak, Verena; Rodekamp, Elke; Brauer, Martin; Hinkson, Larry; Kalache, Karim; Henrich, Wolfgang
2018-06-01
We undertook a randomized clinical trial to examine the outcome of a single vs. a double layer uterine closure using ultrasound to assess uterine scar thickness. Participating women were allocated to one of three uterotomy suture techniques: continuous single layer unlocked suturing, continuous locked single layer suturing, or double layer suturing. Transvaginal ultrasound of uterine scar thickness was performed 6 weeks and 6 - 24 months after Cesarean delivery. Sonographers were blinded to the closure technique. An "intent-to-treat" and "as treated" ANOVA analysis included 435 patients (n = 149 single layer unlocked suturing, n = 157 single layer locked suturing, and n = 129 double layer suturing). 6 weeks postpartum, the median scar thickness did not differ among the three groups: 10.0 (8.5 - 12.3 mm) single layer unlocked vs. 10.1 (8.2 - 12.7 mm) single layer locked vs. 10.8 (8.1 - 12.8 mm) double layer; (p = 0.84). At the time of the second follow-up, the uterine scar was not significantly (p = 0.06) thicker if the uterus had been closed with a double layer closure 7.3 (5.7 - 9.1 mm), compared to single layer unlocked 6.4 (5.0 - 8.8 mm) or locked suturing techniques 6.8 (5.2 - 8.7 mm). Women who underwent primary or elective Cesarean delivery showed a significantly (p = 0.03, p = 0.02, "as treated") increased median scar thickness after double layer closure vs. single layer unlocked suture. A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients. © Georg Thieme Verlag KG Stuttgart · New York.
Ultrasound elastography: the new frontier in direct measurement of muscle stiffness.
Brandenburg, Joline E; Eby, Sarah F; Song, Pengfei; Zhao, Heng; Brault, Jeffrey S; Chen, Shigao; An, Kai-Nan
2014-11-01
The use of brightness-mode ultrasound and Doppler ultrasound in physical medicine and rehabilitation has increased dramatically. The continuing evolution of ultrasound technology has also produced ultrasound elastography, a cutting-edge technology that can directly measure the mechanical properties of tissue, including muscle stiffness. Its real-time and direct measurements of muscle stiffness can aid the diagnosis and rehabilitation of acute musculoskeletal injuries and chronic myofascial pain. It can also help monitor outcomes of interventions affecting muscle in neuromuscular and musculoskeletal diseases, and it can better inform the functional prognosis. This technology has implications for even broader use of ultrasound in physical medicine and rehabilitation practice, but more knowledge about its uses and limitations is essential to its appropriate clinical implementation. In this review, we describe different ultrasound elastography techniques for studying muscle stiffness, including strain elastography, acoustic radiation force impulse imaging, and shear-wave elastography. We discuss the basic principles of these techniques, including the strengths and limitations of their measurement capabilities. We review the current muscle research, discuss physiatric clinical applications of these techniques, and note directions for future research. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Jamniczky, Heather A; Cotton, Darrel; Paget, Michael; Ramji, Qahir; Lenz, Ryan; McLaughlin, Kevin; Coderre, Sylvain; Ma, Irene W Y
2017-03-01
Ultrasonography is increasingly used in medical education, but its impact on learning outcomes is unclear. Adding ultrasound may facilitate learning, but may also potentially overwhelm novice learners. Based upon the framework of cognitive load theory, this study seeks to evaluate the relationship between cognitive load associated with using ultrasound and learning outcomes. The use of ultrasound was hypothesized to facilitate learning in anatomy for 161 novice first-year medical students. Using linear regression analyses, the relationship between reported cognitive load on using ultrasound and learning outcomes as measured by anatomy laboratory examination scores four weeks after ultrasound-guided anatomy training was evaluated in consenting students. Second anatomy examination scores of students who were taught anatomy with ultrasound were compared with historical controls (those not taught with ultrasound). Ultrasound's perceived utility for learning was measured on a five-point scale. Cognitive load on using ultrasound was measured on a nine-point scale. Primary outcome was the laboratory examination score (60 questions). Learners found ultrasound useful for learning. Weighted factor score on "image interpretation" was negatively, but insignificantly, associated with examination scores [F (1,135) = 0.28, beta = -0.22; P = 0.61]. Weighted factor score on "basic knobology" was positively and insignificantly associated with scores; [F (1,138) = 0.27, beta = 0.42; P = 0.60]. Cohorts exposed to ultrasound had significantly higher scores than historical controls (82.4% ± SD 8.6% vs. 78.8% ± 8.5%, Cohen's d = 0.41, P < 0.001). Using ultrasound to teach anatomy does not negatively impact learning and may improve learning outcomes. Anat Sci Educ 10: 144-151. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.
Singh, M Suheshkumar; Yalavarthy, Phaneendra K; Vasu, R M; Rajan, K
2010-07-01
To assess the effect of ultrasound modulation of near infrared (NIR) light on the quantification of scattering coefficient in tissue-mimicking biological phantoms. A unique method to estimate the phase of the modulated NIR light making use of only time averaged intensity measurements using a charge coupled device camera is used in this investigation. These experimental measurements from tissue-mimicking biological phantoms are used to estimate the differential pathlength, in turn leading to estimation of optical scattering coefficient. A Monte-Carlo model based numerical estimation of phase in lieu of ultrasound modulation is performed to verify the experimental results. The results indicate that the ultrasound modulation of NIR light enhances the effective scattering coefficient. The observed effective scattering coefficient enhancement in tissue-mimicking viscoelastic phantoms increases with increasing ultrasound drive voltage. The same trend is noticed as the ultrasound modulation frequency approaches the natural vibration frequency of the phantom material. The contrast enhancement is less for the stiffer (larger storage modulus) tissue, mimicking tumor necrotic core, compared to the normal tissue. The ultrasound modulation of the insonified region leads to an increase in the effective number of scattering events experienced by NIR light, increasing the measured phase, causing the enhancement in the effective scattering coefficient. The ultrasound modulation of NIR light could provide better estimation of scattering coefficient. The observed local enhancement of the effective scattering coefficient, in the ultrasound focal region, is validated using both experimental measurements and Monte-Carlo simulations.
Clinical workflow for spinal curvature measurement with portable ultrasound
NASA Astrophysics Data System (ADS)
Tabanfar, Reza; Yan, Christina; Kempston, Michael; Borschneck, Daniel; Ungi, Tamas; Fichtinger, Gabor
2016-03-01
PURPOSE: Spinal curvature monitoring is essential in making treatment decisions in scoliosis. Monitoring entails radiographic examinations, however repeated ionizing radiation exposure has been shown to increase cancer risk. Ultrasound does not emit ionizing radiation and is safer for spinal curvature monitoring. We investigated a clinical sonography protocol and challenges associated with position-tracked ultrasound in spinal curvature measurement in scoliosis. METHODS: Transverse processes were landmarked along each vertebra using tracked ultrasound snapshots. The transverse process angle was used to determine the orientation of each vertebra. We tested our methodology on five patients in a local pediatric scoliosis clinic, comparing ultrasound to radiographic curvature measurements. RESULTS: Despite strong correlation between radiographic and ultrasound curvature angles in phantom studies, we encountered new challenges in the clinical setting. Our main challenge was differentiating transverse processes from ribs and other structures during landmarking. We observed up to 13° angle variability for a single vertebra and a 9.85° +/- 10.81° difference between ultrasound and radiographic Cobb angles for thoracic curvatures. Additionally, we were unable to visualize anatomical landmarks in the lumbar region where soft tissue depth was 25-35mm. In volunteers with large Cobb angles (greater than 40° thoracic and 60° lumbar), we observed spinal protrusions resulting in incomplete probe-skin contact and partial ultrasound images not suitable for landmarking. CONCLUSION: Spinal curvature measurement using tracked ultrasound is viable on phantom spine models. In the clinic, new challenges were encountered which must be resolved before a universal sonography protocol can be developed.
Ultrasound use for body composition and carcass quality assessment in cattle and lambs
USDA-ARS?s Scientific Manuscript database
Genetic evaluation for carcass quality traits has evolved over time, in large part due to introduction of new technology such as ultrasound measures of body composition. Ultrasound measured body composition traits emulate important carcass traits, are very informative for selection purposes, are ac...
Pau, Cindy T; Keefe, Candace; Duran, Jessica; Welt, Corrine K
2014-05-01
Although metformin is widely used to improve insulin resistance in women with polycystic ovary syndrome (PCOS), its mechanism of action is complex, with inconsistent effects on insulin sensitivity and variability in treatment response. The aim of the study was to delineate the effect of metformin on glucose and insulin parameters, determine additional treatment outcomes, and predict patients with PCOS who will respond to treatment. We conducted an open-label, interventional study at an academic medical center. Women with PCOS (n = 36) diagnosed by the National Institutes of Health criteria participated in the study. Subjects underwent fasting blood sampling, an IV glucose tolerance test, dual-energy x-ray absorptiometry scan, transvaginal ultrasound, and measurement of human chorionic gonadotropin-stimulated androgen levels before and after 12 weeks of treatment with metformin extended release 1500 mg/d. Interval visits were performed to monitor anthropometric measurements and menstrual cycle parameters. Changes in glucose and insulin parameters, androgen levels, anthropometric measurements, and ovulatory menstrual cycles were evaluated. Insulin sensitivity did not change despite weight loss. Glucose effectiveness (P = .002) and the acute insulin response to glucose (P = .002) increased, and basal glucose levels (P = .001) decreased after metformin treatment. T levels also decreased. Women with improved ovulatory function (61%) had lower baseline T levels and lower baseline and stimulated T and androstenedione levels after metformin treatment (all P < .05). Using an IV glucose tolerance test, which distinguishes improvements in glucose effectiveness and insulin sensitivity, metformin does not improve insulin sensitivity in women with PCOS but does improve glucose effectiveness. The improvement in glucose effectiveness may be partially mediated by decreased glucose levels. T levels also decreased with metformin treatment. Ovulation during metformin treatment was associated with lower baseline T levels and greater T and androstenedione decreases during treatment, but not with insulin or LH levels. Thus, the action of metformin in PCOS primarily affects glucose levels and steroidogenesis, which may be mediated by mechanisms that affect both pathways, such as inhibition of mitochondrial complex I.
van Dyk, Sylvia; Garth, Margaret; Oates, Amanda; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash
2016-01-01
To validate interoperator reliability of brachytherapy radiation therapists (RTs) in obtaining an ultrasound image and measuring the cervix and uterine dimensions using transabdominal ultrasound. Patients who underwent MRI with applicators in situ after the first insertion were included in the study. Imaging was performed by three RTs (RT1, RT2, and RT3) with varying degrees of ultrasound experience. All RTs were required to obtain a longitudinal planning image depicting the applicator in the uterine canal and measure the cervix and uterus. The MRI scan, taken 1 hour after the ultrasound, was used as the reference standard against which all measurements were compared. Measurements were analyzed with intraclass correlation coefficient and Bland-Altman plots. All RTs were able to obtain a suitable longitudinal image for each patient in the study. Mean differences (SD) between MRI and ultrasound measurements obtained by RTs ranged from 3.5 (3.6) to 4.4 (4.23) mm and 0 (3.0) to 0.9 (2.5) mm on the anterior and posterior surface of the cervix, respectively. Intraclass correlation coefficient for absolute agreement between MRI and RTs was >0.9 for all posterior measurement points in the cervix and ranged from 0.41 to 0.92 on the anterior surface. Measurements were not statistically different between RTs at any measurement point. RTs with variable training attained high levels of interoperator reliability when using transabdominal ultrasound to obtain images and measurements of the uterus and cervix with brachytherapy applicators in situ. Access to training and use of a well-defined protocol assist in achieving these high levels of reliability. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024
Reproducibility of abdominal fat assessment by ultrasound and computed tomography.
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
Comparative evaluation of ultrasound scanner accuracy in distance measurement
NASA Astrophysics Data System (ADS)
Branca, F. P.; Sciuto, S. A.; Scorza, A.
2012-10-01
The aim of the present study is to develop and compare two different automatic methods for accuracy evaluation in ultrasound phantom measurements on B-mode images: both of them give as a result the relative error e between measured distances, performed by 14 brand new ultrasound medical scanners, and nominal distances, among nylon wires embedded in a reference test object. The first method is based on a least squares estimation, while the second one applies the mean value of the same distance evaluated at different locations in ultrasound image (same distance method). Results for both of them are proposed and explained.
Lindberg, Lars; Johansson, Sune; Perez-de-Sa, Valeria
2014-02-01
To validate cardiac output measurements by ultrasound dilution technology (COstatus monitor) against those obtained by a transit-time ultrasound technology with a perivascular flow probe and to investigate ultrasound dilution ability to estimate pulmonary to systemic blood flow ratio in children. Prospective observational clinical trial. Pediatric cardiac operating theater in a university hospital. In 21 children (6.1 ± 2.6 kg, mean ± SD) undergoing heart surgery, cardiac output was simultaneously recorded by ultrasound dilution (extracorporeal arteriovenous loop connected to existing arterial and central venous catheters) and a transit-time ultrasound probe applied to the ascending aorta, and when possible, the main pulmonary artery. The pulmonary to systemic blood flow ratio estimated from ultrasound dilution curve analysis was compared with that estimated from transit-time ultrasound technology. Bland-Altman analysis of the whole cohort (90 pairs, before and after surgery) showed a bias between transit-time ultrasound (1.01 ± 0.47 L/min) and ultrasound dilution technology (1.03 ± 0.51 L/min) of -0.02 L/min, limits of agreement -0.3 to 0.3 L/min, and percentage error of 31%. In children with no residual shunts, the bias was -0.04 L/min, limits of agreement -0.28 to 0.2 L/min, and percentage error 19%. The pooled co efficient of variation was for the whole cohort 3.5% (transit-time ultrasound) and 6.3% (ultrasound dilution), and in children without shunt, it was 2.9% (transit-time ultrasound) and 4% (ultrasound dilution), respectively. Ultrasound dilution identified the presence of shunts (pulmonary to systemic blood flow ≠ 1) with a sensitivity of 100% and a specificity of 92%. Mean pulmonary to systemic blood flow ratio by transit-time ultrasound was 2.6 ± 1.0 and by ultrasound dilution 2.2 ± 0.7 (not significant). The COstatus monitor is a reliable technique to measure cardiac output in children with high sensitivity and specificity for detecting the presence of shunts.
Giampaolino, Pierluigi; Morra, Ilaria; Tommaselli, Giovanni Antonio; Di Carlo, Costantino; Nappi, Carmine; Bifulco, Giuseppe
2016-10-01
To compare conventional laparoscopic ovarian drilling (LOD) with transvaginal hydrolaparoscopy (THL) ovarian drilling in terms of ovarian adhesion formation, evaluated using office THL during follow-up in CC-resistant anovulatory patients affected by PCOS. Prospective randomized study on 246 CC-resistant women with PCOS. The patients enrolled were divided into two groups, 123 were scheduled to undergo LOD and 123 to undergo THL ovarian drilling. Six months after the procedure all patients were offered office transvaginal hydrolaparoscopy (THL) follow-up, under local anesthesia to evaluate adhesion formation. Duration of the procedure was significantly shorter in the THL group in comparison with LOD group (p < 0.0001). No intra- or post-operative complication was observed in any of the patients in both groups. Post-operative THL follow-up after 6 months showed that 15 (15.5 %) patients in the THL group and 73 (70.2 %) in the LOD group showed the presence of ovarian adhesion. This difference was highly significant with a p value <0.0001 and a relative risk of 0.22 [95 % IC 0.133-0.350]. This study seems to indicate that THL ovarian drilling may reduce the risk of ovarian adhesion formation and could be used as a safe and effective option to reduce ovarian adhesion formation in patients undergoing ovarian drilling.
Cho, M K; Kim, C H; Kang, W D; Kim, J W; Kim, S M; Kim, Y H
2012-04-01
The study was undertaken to compare the clinical and quality-of-life (QoL) outcomes of the inside-out transobturator vaginal tape (TVT-O)-only procedures and TVT-O procedures with concomitant transvaginal gynaecological surgery for the treatment of stress urinary incontinence (SUI). A review of charts from January 2006 to March 2010 identified 305 patients with urodynamic stress incontinence for whom we performed the TVT-O. Of the initial 305 patients, 272 (89.2%) were re-examined for complications 1 month, 4 months, 1 year and 2-4 years postoperatively (122 TVT-O only; 150 TVT-O + other transvaginal gynaecological surgery). They were also evaluated with the Urogenital Distress Inventory Questionnaire (UDI-6) and the Incontinence Impact Questionnaire (IIQ-7) 1-4 years after the procedure. The median follow-up was 37.3 months. The success rate was 89.3% in the TVT-O-only group vs 93.3% in the TVT-O with concomitant gynaecological surgery group (p =0.729). The QoL score was quite good for 91.8% of the TVT-O-only patients and for 96.7% of the TVT-O with concomitant gynaecologic surgery patients (p =0.405). In conclusion, gynaecological operations performed concomitantly with the TVT-O procedure do not affect the clinical and QoL outcomes of the TVT-O procedure.
Fan, Joe K. M.; Tong, Daniel K. H.; HO, David W. Y.; Luk, John; Law, Simon
2009-01-01
Objective: We analyzed circulating TNF-α and IL-6 to determine systemic inflammatory responses associated with transvaginal cholecystectomy in a porcine model. Methods: Six female pigs were used for a survival study after transvaginal cholecystectomy (NOTES group) using endoscopic submucosal dissection (ESD) instruments and a single-channel endoscope. Blood was drawn preoperatively and 24 hours and 48 hours postoperatively. Four pigs were used as controls. In addition, laparoscopic cholecystectomy was performed in 2 pigs for laparoscopic control. Results: In all 6 pigs in the NOTES group, no major intraoperative complications occurred. No significant differences were found between control, laparoscopic, and NOTES groups in terms of preoperative IL-6 level (P=0.897) and at 24 hours (P=0.790), and 48 hours postoperatively (P=0.945). Similarly, there was no significant difference in mean preoperative (P=0.349) and mean day 2 postoperative TNF-α levels (P=0.11). But a significant increase in day 1 postoperative TNF-α levels in the laparoscopic group compared with that in the control and NOTES groups was observed (P=0.049). One limitation of our study is that the sample size was relatively small. Conclusion: NOTES is safe in animal models in terms of anatomical and cellular level changes with minimal systemic inflammatory host responses elicited. Further study needs to be carried out in humans before NOTES can be recommended for routine use. PMID:19366533
Descargues, G; Lemercier, E; David, C; Genevois, A; Lemoine, J P; Marpeau, L
2001-02-01
Evaluate the feasibility and the value of hysterography, sonohysterography and hysteroscopy for investigation of abnormal uterine bleeding. Method. Longitudinal blind study of thirty-eight patients consulting for abnormal uterine bleeding during pre- and post menopause. All patients underwent an hysterography and transvaginal sonohysterography, in random order, followed by an hysteroscopy with histological sample. The results were compared with the histo-pathological examination that was used for reference diagnosis. Statistical study of sensitivity, specificity and Positive and Negative Predictive Value (PPV-NPV) of each investigation; rate of agreement by the coefficient of Kappa. The hysterography offers a PPV of 83% and a NPV of 100%. The interpretation errors were associated with the simple mucous hypertrophy interpreted as "hyperplasy". The limits correspond to a contrast agent allergy. The sonohysterography had a VPP of 89% and a VPN of 100%. The false positive is due to the difficulties of distinguishing the clots from the polyps. The limits correspond to the difficulties of cervix catheterization (13%). As regards the hysteroscopy, the VPP was 81.5% and the VPN of 75%. The interpretation mistakes were associated with mucous hypertrophy and the hyperplasy. The most useful examination for abnormal uterine bleeding, in the first instance, is transvaginal sonography with saline instillation. A complement by Doppler study would probably make it possible to limit the false positives.
Ovarian surgery for symptom relief in women with polycystic ovary syndrome.
Lepine, Sam; Jo, Junyoung; Metwally, Mostafa; Cheong, Ying C
2017-11-10
Polycystic ovary syndrome (PCOS) is a common endocrine condition, affecting approximately one in 10 women. PCOS is defined by two of three features: oligo- or anovulation, clinical or biochemical hyperandrogenism or both, or polycystic ovaries.Women with PCOS can have a wide range of health problems, including infrequent and irregular periods, unwanted hair growth and acne, and subnormal fertility. Long-term health concerns include an increased risk of heart disease, diabetes and the development of precancerous disease of the womb. To assess the effectiveness and harms of ovarian surgery as a treatment for symptomatic relief of hirsutism, acne and menstrual irregularity in PCOS. We searched the Cochrane Gynaecology and Fertility Group specialized register, CENTRAL, MEDLINE, Embase and PsycINFO (from inception to 17 October 2016). We handsearched citation lists, registers of ongoing trials and conference proceedings. We included randomized controlled trials (RCTs) of women undergoing ovarian drilling in comparison to no treatment, medical treatment, or other forms of surgical treatment for the symptoms of PCOS. We used standard methodological procedures recommended by Cochrane. The primary outcome measures were improvement in menstrual regularity and androgenic symptoms of PCOS (hirsutism, acne); the secondary outcome measures included harms, change of body mass index (BMI), waist circumference, androgen levels, metabolic measures and quality of life. We assessed the quality of the evidence using GRADE methods. We included 22 RCTs (2278 women analyzed) of participants with PCOS and symptoms of acne, hirsutism or irregular menstrual cycles, all of which included laparoscopic ovarian drilling (LOD) as an intervention.Two studies reported their funding source (Farquhar 2002 - supported in part by the Auckland Medical Research Foundation; Sarouri 2015 - the authors thank the Vice Chancellor for Research of Guilan University of Medical Sciences for funding this project).The quality of the evidence ranged from very low to moderate quality. The main limitations were imprecision associated with the low number of studies, inconsistency and risk of bias associated with the inability to blind participants. There were too few studies to assess risk of publication bias. Menstrual RegularityTwo studies compared LOD versus metformin (n=226) but no conclusions could be drawn with regard to menstrual regularity, as their findings were inconsistent and they were unsuitable for pooling. There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when LOD was compared with medical treatment including metformin + clomiphene (OR 1.02, 95% CI 0.64 to 1.64, 2 studies, 332 women, I 2 = 13%, low-quality evidence), letrozole (OR 1.08, 95% CI 0.64 to 1.84, 1 study, 260 women, low-quality evidence), or metformin + letrozole (OR 0.95, 95% CI 0.49 to 1.81, 1 study, 146 women, low-quality evidence). However, one study reported that LOD was superior to gonadotrophin (OR 19.2, 95% CI 3.17 to 116.45, 1 study, 35 women, very low-quality evidence).There appeared to be little or no difference in the rate of women reporting improvement in menstrual regularity when bilateral unipolar LOD was compared to unilateral LOD (OR 1.51, 95% CI 0.62 to 3.71, 2 studies, 104 women, I 2 = 0%, moderate-quality evidence), transvaginal ultrasound-guided LOD (OR 1.23, 95% CI 0.64 to 2.37, 1 study, 147 women, low-quality evidence), LOD using adjusted thermal dose in accordance with the ovarian volume (OR 0.42, 95% CI 0.16 to 1.14, 1 study, 115 women, low-quality evidence) or bipolar LOD (OR 1.00, 95% CI 0.05 to 18.57, 1 study, 18 women, low-quality evidence).Four to five punctures per ovary may improve the rate of women reporting menstrual regularity compared with two or fewer (OR 16.04, 95% CI 4.19 to 61.34, 2 studies, 73 women, I 2 = 0%, low-quality evidence). Androgenic SymptomsThere was probably little or no difference in improvement in androgenic symptoms when LOD was compared to metformin (OR 1.00, 95% CI 0.42 to 2.37, 1 study, 126 women, moderate-quality evidence) or gonadotrophins; acne (OR 3.20, 95% CI 0.33 to 30.94, 1 study, 25 women, low-quality evidence), hirsutism (OR 2.31, 95% CI 0.22 to 23.89, 1 study, 25 women, low-quality evidence).There appeared to be little or no difference in improvement of androgenic symptoms when LOD was compared to transvaginal ultrasound-guided LOD, with respect to hirsutism (OR 1.09, 95% CI 0.30 to 3.91, 1 study, 39 women, low-quality evidence) or acne (OR 0.84, 95% CI 0.20 to 3.50, 1 study, 31 women, low-quality evidence). HarmsLOD was associated with fewer gastrointestinal side effects than metformin plus clomiphene (OR 0.05, 95% CI 0.01 to 0.36, 2 studies, 332 women, I 2 = 0%, moderate-quality evidence). One study suggested little or no difference in rates of ovarian hyperstimulation syndrome between LOD and gonadotrophins (OR 0.08, 95% CI 0.00 to 1.61, 1 study, 33 women, low-quality evidence).There were fewer adhesions with transvaginal hydrolaparoscopy compared to LOD (OR 0.10, 95% CI 0.05 to 0.18, 1 study, 246 women, moderate-quality evidence). There appeared to be little or no difference in adhesions when variable energy LOD was compared with standard LOD (OR 0.96, 95% CI 0.32 to 2.88, 1 study, 64 women, low-quality evidence). Another study (44 women) reported that none of the women who returned for surgery following either traditional or unilateral LOD were found to have adhesions. There was no clear evidence that LOD improves menstrual regularity or the androgenic symptoms of PCOS, compared to most of the medical treatments used in the included studies. LOD was associated with fewer gastrointestinal side effects compared to metformin and clomiphene.There was also no clear evidence of different effectiveness between types of LOD, except that LOD with four to five punctures per ovary may be more effective than two or fewer punctures. There was little evidence comparing LOD with different types of surgery, although one study concluded that transvaginal hydrolaparoscopy had a lower risk of adhesions than LOD.There was evidence from one small study of benefit from LOD compared to gonadotrophins for menstrual regulation. However, gonadotrophins are seldom used for this indication.
Medical Imaging with Ultrasound: Some Basic Physics.
ERIC Educational Resources Information Center
Gosling, R.
1989-01-01
Discussed are medical applications of ultrasound. The physics of the wave nature of ultrasound including its propagation and production, return by the body, spatial and contrast resolution, attenuation, image formation using pulsed echo ultrasound techniques, measurement of velocity and duplex scanning are described. (YP)
Timmerman, Dirk; Van Calster, Ben; Testa, Antonia; Savelli, Luca; Fischerova, Daniela; Froyman, Wouter; Wynants, Laure; Van Holsbeke, Caroline; Epstein, Elisabeth; Franchi, Dorella; Kaijser, Jeroen; Czekierdowski, Artur; Guerriero, Stefano; Fruscio, Robert; Leone, Francesco P G; Rossi, Alberto; Landolfo, Chiara; Vergote, Ignace; Bourne, Tom; Valentin, Lil
2016-04-01
Accurate methods to preoperatively characterize adnexal tumors are pivotal for optimal patient management. A recent metaanalysis concluded that the International Ovarian Tumor Analysis algorithms such as the Simple Rules are the best approaches to preoperatively classify adnexal masses as benign or malignant. We sought to develop and validate a model to predict the risk of malignancy in adnexal masses using the ultrasound features in the Simple Rules. This was an international cross-sectional cohort study involving 22 oncology centers, referral centers for ultrasonography, and general hospitals. We included consecutive patients with an adnexal tumor who underwent a standardized transvaginal ultrasound examination and were selected for surgery. Data on 5020 patients were recorded in 3 phases from 2002 through 2012. The 5 Simple Rules features indicative of a benign tumor (B-features) and the 5 features indicative of malignancy (M-features) are based on the presence of ascites, tumor morphology, and degree of vascularity at ultrasonography. Gold standard was the histopathologic diagnosis of the adnexal mass (pathologist blinded to ultrasound findings). Logistic regression analysis was used to estimate the risk of malignancy based on the 10 ultrasound features and type of center. The diagnostic performance was evaluated by area under the receiver operating characteristic curve, sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), negative predictive value (NPV), and calibration curves. Data on 4848 patients were analyzed. The malignancy rate was 43% (1402/3263) in oncology centers and 17% (263/1585) in other centers. The area under the receiver operating characteristic curve on validation data was very similar in oncology centers (0.917; 95% confidence interval, 0.901-0.931) and other centers (0.916; 95% confidence interval, 0.873-0.945). Risk estimates showed good calibration. In all, 23% of patients in the validation data set had a very low estimated risk (<1%) and 48% had a high estimated risk (≥30%). For the 1% risk cutoff, sensitivity was 99.7%, specificity 33.7%, LR+ 1.5, LR- 0.010, PPV 44.8%, and NPV 98.9%. For the 30% risk cutoff, sensitivity was 89.0%, specificity 84.7%, LR+ 5.8, LR- 0.13, PPV 75.4%, and NPV 93.9%. Quantification of the risk of malignancy based on the Simple Rules has good diagnostic performance both in oncology centers and other centers. A simple classification based on these risk estimates may form the basis of a clinical management system. Patients with a high risk may benefit from surgery by a gynecological oncologist, while patients with a lower risk may be managed locally. Copyright © 2016 Elsevier Inc. All rights reserved.
Airborne ultrasound applied to anthropometry--physical and technical principles.
Lindström, K; Mauritzson, L; Benoni, G; Willner, S
1983-01-01
Airborne ultrasound has been utilized for remote measurement of distance, direction, size, form, volume and velocity. General anthropometrical measurements are performed with a newly constructed real-time linear array scanner. To make full use of the method, we expect a rapid development of high-frequency ultrasound transducers for use in air.
Calibration and Evaluation of Ultrasound Thermography Using Infrared Imaging.
Hsiao, Yi-Sing; Deng, Cheri X
2016-02-01
Real-time monitoring of the spatiotemporal evolution of tissue temperature is important to ensure safe and effective treatment in thermal therapies including hyperthermia and thermal ablation. Ultrasound thermography has been proposed as a non-invasive technique for temperature measurement, and accurate calibration of the temperature-dependent ultrasound signal changes against temperature is required. Here we report a method that uses infrared thermography for calibration and validation of ultrasound thermography. Using phantoms and cardiac tissue specimens subjected to high-intensity focused ultrasound heating, we simultaneously acquired ultrasound and infrared imaging data from the same surface plane of a sample. The commonly used echo time shift-based method was chosen to compute ultrasound thermometry. We first correlated the ultrasound echo time shifts with infrared-measured temperatures for material-dependent calibration and found that the calibration coefficient was positive for fat-mimicking phantom (1.49 ± 0.27) but negative for tissue-mimicking phantom (-0.59 ± 0.08) and cardiac tissue (-0.69 ± 0.18°C-mm/ns). We then obtained the estimation error of the ultrasound thermometry by comparing against the infrared-measured temperature and revealed that the error increased with decreased size of the heated region. Consistent with previous findings, the echo time shifts were no longer linearly dependent on temperature beyond 45°C-50°C in cardiac tissues. Unlike previous studies in which thermocouples or water bath techniques were used to evaluate the performance of ultrasound thermography, our results indicate that high-resolution infrared thermography is a useful tool that can be applied to evaluate and understand the limitations of ultrasound thermography methods. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Huang, Chih-Chung; Lee, Po-Yang; Chen, Pay-Yu; Liu, Ting-Yu
2012-01-01
Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications. © 2012 IEEE
ERIC Educational Resources Information Center
Hughes, Stephen
2001-01-01
Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)
Lin, Kao-Han; Young, Sun-Yi; Hsu, Ming-Chuan; Chan, Hsu; Chen, Yung-Yaw; Lin, Win-Li
2008-01-01
In this study, we developed a focused ultrasound (FUS) thermal therapy system with ultrasound image guidance and thermocouple temperature measurement feedback. Hydraulic position devices and computer-controlled servo motors were used to move the FUS transducer to the desired location with the measurement of actual movement by linear scale. The entire system integrated automatic position devices, FUS transducer, power amplifier, ultrasound image system, and thermocouple temperature measurement into a graphical user interface. For the treatment procedure, a thermocouple was implanted into a targeted treatment region in a tissue-mimicking phantom under ultrasound image guidance, and then the acoustic interference pattern formed by image ultrasound beam and low-power FUS beam was employed as image guidance to move the FUS transducer to have its focal zone coincident with the thermocouple tip. The thermocouple temperature rise was used to determine the sonication duration for a suitable thermal lesion as a high power was turned on and ultrasound image was used to capture the thermal lesion formation. For a multiple lesion formation, the FUS transducer was moved under the acoustic interference guidance to a new location and then it sonicated with the same power level and duration. This system was evaluated and the results showed that it could perform two-dimensional motion control to do a two-dimensional thermal therapy with a small localization error 0.5 mm. Through the user interface, the FUS transducer could be moved to heat the target region with the guidance of ultrasound image and acoustic interference pattern. The preliminary phantom experimental results demonstrated that the system could achieve the desired treatment plan satisfactorily.
Ultrasound-enhanced localized chemotherapy of drug-sensitive and multidrug resistant tumors
NASA Astrophysics Data System (ADS)
Rapoport, Natalya Y.; Gao, Zhonggao; Kamaev, Pavel; Christensen, Douglas A.
2006-05-01
A new modality of targeted tumor chemotherapy is based on the drug encapsulation in polymeric nanoparticles followed by a localized release at the tumor site triggered by focused ultrasound. Effect of 1 MHz and 3 MHz unfocused ultrasound applied locally to the tumor on the Doxorubicin (DOX) biodistribution and tumor growth rates was measured for ovarian carcinoma tumors in nu/nu mice. The bioeffects of ultrasound were investigated on the systemic and cellular levels. Growth rates of A2780 ovarian carcinoma tumors were substantially reduced by combining micellar drug delivery with tumor irradiation. Ultrasound effect was not thermal as manifested by intratumoral temperature measurements during sonication. Biodistribution studies showed that ultrasound did not enhance micelle extravasation. Main mechanisms of the ultrasound-enhanced chemotherapy included (i) passive targeting of drug-loaded micelles to the tumor interstitium; (ii) ultrasound-triggered localized drug release from micelles in the tumor volume; (iii) enhanced micelle and drug diffusion through the tumor interstitium; and (iv) ultrasound-triggered cell membrane damage resulting in the enhanced micelle and drug uptake by tumor cells.
Sonographic appearance of anal cushions of hemorrhoids
Aimaiti, Adilijiang; A Ba Bai Ke Re, Ma Mu Ti Jiang; Ibrahim, Irshat; Chen, Hui; Tuerdi, Maimaitituerxun; Mayinuer
2017-01-01
AIM To evaluate the diagnostic value of different sonographic methods in hemorrhoids. METHODS Forty-two healthy volunteers and sixty-two patients with grades I-IV hemorrhoids received two different sonographic examinations from January 2013 to January 2016 at the First and Second Hospitals of Xinjiang Medical University in a prospective way. We analyzed the ultrasonographic findings of these participants and evaluated the outcomes. Resected grades III and IV hemorrhoid tissues were pathologically examined. The concordance of ultrasonographic results with pathology results was assessed with the Cohen’s kappa coefficient. RESULTS All healthy volunteers and all patients had no particular complications related to sonography. There were no statistically significant differences between the participants regarding age (P = 0.5919), gender (P = 0.4183), and persistent symptoms (P > 0.8692). All healthy control participants had no special findings. However, 30 patients with hemorrhoids showed blood signals around the dentate line on ultrasonography. When grades I and II hemorrhoids were analyzed, there were no significant differences between transrectal ultrasound (TRUS), transperianal ultrasound (TPUS), and transvaginal ultrasound (TVUS) (P > 0.05). Grades III and IV hemorrhoids revealed blood flow with different directions which could be observed as a “mosaic pattern”. In patients with grades III and IV hemorrhoids, the number of patients with “mosaic pattern” as revealed by TRUS, TPUS and TVUS was 22, 12, and 4, respectively. Patients with grades III and IV disease presented with a pathologically abnormal cushion which usually appeared as a “mosaic pattern” in TPUS and an arteriovenous fistula in pathology. Subepithelial vessels of resected grades III and IV hemorrhoid tissues were manifested by obvious structural impairment and retrograde and ruptured changes of internal elastic lamina. Some parts of the Trietz’s muscle showed hypertrophy and distortion. Arteriovenous fistulas and venous dilatation were obvious in the anal cushion of hemorhoidal tissues. After pathological results with arteriovenous fistulas were taken as the standard reference, we evaluated the compatibility between the two methods according to the Cohen’s kappa co-efficiency calculation. The compatibility (Cohein kappa co-efficiency value) between “mosaic pattern” in the TPUS and arteriovenous fistula in pathology was very good (ĸ = 0.8939). When compared between different groups, TRUS presented the advantage that the mosaic pattern could be confirmed in more patients, especially for group A. There was a statistical difference when comparing group A with group B or C (P < 0.05 for both). There were obvious statistical differences between group A and group B with regard to the vessel diameter and blood flow velocity measured by TRUS (P < 0.05). CONCLUSION Patients with grades III and IV hemorrhoids present with a pathologically abnormal cushion which usually appears as a “mosaic pattern” in sonography, which is in accord with an arteriovenous fistula in pathology. There are clearly different hemorrhoid structures shown by sonography. “Mosaic pattern” may be a parameter for surgical indication of grades III and IV hemorrhoids. PMID:28611519
Sonographic appearance of anal cushions of hemorrhoids.
Aimaiti, Adilijiang; A Ba Bai Ke Re, Ma Mu Ti Jiang; Ibrahim, Irshat; Chen, Hui; Tuerdi, Maimaitituerxun; Mayinuer
2017-05-28
To evaluate the diagnostic value of different sonographic methods in hemorrhoids. Forty-two healthy volunteers and sixty-two patients with grades I-IV hemorrhoids received two different sonographic examinations from January 2013 to January 2016 at the First and Second Hospitals of Xinjiang Medical University in a prospective way. We analyzed the ultrasonographic findings of these participants and evaluated the outcomes. Resected grades III and IV hemorrhoid tissues were pathologically examined. The concordance of ultrasonographic results with pathology results was assessed with the Cohen's kappa coefficient. All healthy volunteers and all patients had no particular complications related to sonography. There were no statistically significant differences between the participants regarding age ( P = 0.5919), gender ( P = 0.4183), and persistent symptoms ( P > 0.8692). All healthy control participants had no special findings. However, 30 patients with hemorrhoids showed blood signals around the dentate line on ultrasonography. When grades I and II hemorrhoids were analyzed, there were no significant differences between transrectal ultrasound (TRUS), transperianal ultrasound (TPUS), and transvaginal ultrasound (TVUS) ( P > 0.05). Grades III and IV hemorrhoids revealed blood flow with different directions which could be observed as a "mosaic pattern". In patients with grades III and IV hemorrhoids, the number of patients with "mosaic pattern" as revealed by TRUS, TPUS and TVUS was 22, 12, and 4, respectively. Patients with grades III and IV disease presented with a pathologically abnormal cushion which usually appeared as a "mosaic pattern" in TPUS and an arteriovenous fistula in pathology. Subepithelial vessels of resected grades III and IV hemorrhoid tissues were manifested by obvious structural impairment and retrograde and ruptured changes of internal elastic lamina. Some parts of the Trietz's muscle showed hypertrophy and distortion. Arteriovenous fistulas and venous dilatation were obvious in the anal cushion of hemorhoidal tissues. After pathological results with arteriovenous fistulas were taken as the standard reference, we evaluated the compatibility between the two methods according to the Cohen's kappa co-efficiency calculation. The compatibility (Cohein kappa co-efficiency value) between "mosaic pattern" in the TPUS and arteriovenous fistula in pathology was very good (ĸ = 0.8939). When compared between different groups, TRUS presented the advantage that the mosaic pattern could be confirmed in more patients, especially for group A. There was a statistical difference when comparing group A with group B or C ( P < 0.05 for both). There were obvious statistical differences between group A and group B with regard to the vessel diameter and blood flow velocity measured by TRUS ( P < 0.05). Patients with grades III and IV hemorrhoids present with a pathologically abnormal cushion which usually appears as a "mosaic pattern" in sonography, which is in accord with an arteriovenous fistula in pathology. There are clearly different hemorrhoid structures shown by sonography. "Mosaic pattern" may be a parameter for surgical indication of grades III and IV hemorrhoids.
Nagle, Samuel M; Sundar, Guru; Schafer, Mark E; Harris, Gerald R; Vaezy, Shahram; Gessert, James M; Howard, Samuel M; Moore, Mary K; Eaton, Richard M
2013-11-01
This article examines the challenges associated with making acoustic output measurements at high ultrasound frequencies (>20 MHz) in the context of regulatory considerations contained in the US Food and Drug Administration industry guidance document for diagnostic ultrasound devices. Error sources in the acoustic measurement, including hydrophone calibration and spatial averaging, nonlinear distortion, and mechanical alignment, are evaluated, and the limitations of currently available acoustic measurement instruments are discussed. An uncertainty analysis of acoustic intensity and power measurements is presented, and an example uncertainty calculation is done on a hypothetical 30-MHz high-frequency ultrasound system. This analysis concludes that the estimated measurement uncertainty of the acoustic intensity is +73%/-86%, and the uncertainty in the mechanical index is +37%/-43%. These values exceed the respective levels in the Food and Drug Administration guidance document of 30% and 15%, respectively, which are more representative of the measurement uncertainty associated with characterizing lower-frequency ultrasound systems. Recommendations made for minimizing the measurement uncertainty include implementing a mechanical positioning system that has sufficient repeatability and precision, reconstructing the time-pressure waveform via deconvolution using the hydrophone frequency response, and correcting for hydrophone spatial averaging.
Testa, A C; Ferrandina, G; Moro, F; Pasciuto, T; Moruzzi, M C; De Blasis, I; Mascilini, F; Foti, E; Autorino, R; Collarino, A; Gui, B; Zannoni, G F; Gambacorta, M A; Valentini, A L; Rufini, V; Scambia, G
2018-05-01
Chemoradiation-based neoadjuvant treatment followed by radical surgery is an alternative therapeutic strategy for locally advanced cervical cancer (LACC), but ultrasound variables used to predict partial response to neoadjuvant treatment are not well defined. Our goal was to analyze prospectively the potential role of transvaginal ultrasound in early prediction of partial pathological response, assessed in terms of residual disease at histology, in a large, single-institution series of LACC patients triaged to neoadjuvant treatment followed by radical surgery. Between October 2010 and June 2014, we screened 108 women with histologically documented LACC Stage IB2-IVA, of whom 88 were included in the final analysis. Tumor volume, three-dimensional (3D) power Doppler indices and contrast parameters were obtained before (baseline examination) and after 2 weeks of treatment. The pathological response was defined as complete (absence of any residual tumor after treatment) or partial (microscopic and/or macroscopic residual tumor at pathological examination). Complete-response and partial-response groups were compared and receiver-operating characteristics (ROC) curves were generated for ultrasound variables that were statistically significant on univariate analysis to evaluate their diagnostic ability to predict partial pathological response. There was a complete pathological response to neoadjuvant therapy in 40 (45.5%) patients and a partial response in 48 (54.5%). At baseline examination, tumor volume did not differ between the two groups. However, after 2 weeks of neoadjuvant treatment, the tumor volume was significantly greater in patients with partial response than it was in those with complete response (P = 0.019). Among the 3D vascular indices, the vascularization index (VI) was significantly lower in the partial-response compared with the complete-response group, both before and after 2 weeks of treatment (P = 0.037 and P = 0.024, respectively). At baseline examination in the contrast analysis, women with partial response had lower tumor peak enhancement (PE) as well as lower tumor wash-in rate (WiR) and longer tumor rise time (RT) compared with complete responders (P = 0.006, P = 0.003, P = 0.038, respectively). There was no difference in terms of contrast parameters after 2 weeks of treatment. ROC-curve analysis of baseline parameters showed that the best cut-offs for predicting partial pathological response were 41.5% for VI (sensitivity, 63.6%; specificity, 66.7%); 16123.5 auxiliary units for tumor PE (sensitivity, 47.9%; specificity, 84.2%); 7.8 s for tumor RT (sensitivity, 68.8%; specificity, 57.9%); and 4902 for tumor WiR (sensitivity, 77.1%; specificity, 60.5%). ROC curves of parameters after 2 weeks of treatment showed that the best cut-off for predicting partial pathological response was 18.1 cm 3 for tumor volume (sensitivity, 70.8%; specificity 60.0%) and 39.5% for VI (sensitivity; 62.5%; specificity, 73.5%). Ultrasound and contrast parameters differ between LACC patients with complete response and those with partial response before and after 2 weeks of neoadjuvant treatment. However, neither ultrasound parameters before treatment nor those after 2 weeks of treatment had cut-off values with acceptable sensitivity and specificity for predicting partial pathological response to neoadjuvant therapy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
In-Situ Acoustic Measurements of Temperature Profile in Extreme Environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skliar, Mikhail
2015-03-31
A gasifier’s temperature is the primary characteristic that must be monitored to ensure its performance and the longevity of its refractory. One of the key technological challenges impacting the reliability and economics of coal and biomass gasification is the lack of temperature sensors that are capable of providing accurate, reliable, and long-life performance in an extreme gasification environment. This research has proposed, demonstrated, and validated a novel approach that uses a noninvasive ultrasound method that provides real-time temperature distribution monitoring across the refractory, especially the hot face temperature of the refractory. The essential idea of the ultrasound measurements of segmentalmore » temperature distribution is to use an ultrasound propagation waveguide across a refractory that has been engineered to contain multiple internal partial reflectors at known locations. When an ultrasound excitation pulse is introduced on the cold side of the refractory, it will be partially reflected from each scatterer in the US propagation path in the refractory wall and returned to the receiver as a train of partial echoes. The temperature in the corresponding segment can be determined based on recorded ultrasonic waveform and experimentally defined relationship between the speed of sound and temperature. The ultrasound measurement method offers a powerful solution to provide continuous real time temperature monitoring for the occasions that conventional thermal, optical and other sensors are infeasible, such as the impossibility of insertion of temperature sensor, harsh environment, unavailable optical path, and more. Our developed ultrasound system consists of an ultrasound engineered waveguide, ultrasound transducer/receiver, and data acquisition, logging, interpretation, and online display system, which is simple to install on the existing units with minimal modification on the gasifier or use with new units. This system has been successfully tested with a 100 kW pilot scale down flow oxyfuel combustor, capturing in real time temperature changes during all relevant combustion process changes. The ultrasound measurements have excellent agreement with thermo- couple measurements, and appear to be more sensitive to temperature changes before the thermocouples response, which is believed to be the first demonstration of ultrasound measurements segmental temperature distribution across refractories.« less
Uncertainty evaluation of dead zone of diagnostic ultrasound equipment
NASA Astrophysics Data System (ADS)
Souza, R. M.; Alvarenga, A. V.; Braz, D. S.; Petrella, L. I.; Costa-Felix, R. P. B.
2016-07-01
This paper presents a model for evaluating measurement uncertainty of a feature used in the assessment of ultrasound images: dead zone. The dead zone was measured by two technicians of the INMETRO's Laboratory of Ultrasound using a phantom and following the standard IEC/TS 61390. The uncertainty model was proposed based on the Guide to the Expression of Uncertainty in Measurement. For the tested equipment, results indicate a dead zone of 1.01 mm, and based on the proposed model, the expanded uncertainty was 0.17 mm. The proposed uncertainty model contributes as a novel way for metrological evaluation of diagnostic imaging by ultrasound.
Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc Mechanics
2015-01-01
1 AD_________ Award Number: W81XWH-13-1-0050 TITLE: Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine Intervertebral Disc...COVERED 27 Dec 2013 - 26 Dec 2014 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Development of Ultrasound to Measure In-vivo Dynamic Cervical Spine...Approved for Public Release; Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Neck pain is pervasive problems in military population
2010-01-01
Background Echocardiography is the method of choice when one wishes to examine myocardial function. Qualitative assessment of the 2D grey scale images obtained is subjective, and objective methods are required. Speckle Tracking Ultrasound is an emerging technology, offering an objective mean of quantifying left ventricular wall motion. However, before a new ultrasound technology can be adopted in the clinic, accuracy and reproducibility needs to be investigated. Aim It was hypothesized that the collection of ultrasound sample data from an in vitro model could be automated. The aim was to optimize an in vitro model to allow for efficient collection of sample data. Material & Methods A tissue-mimicking phantom was made from water, gelatin powder, psyllium fibers and a preservative. Sonomicrometry crystals were molded into the phantom. The solid phantom was mounted in a stable stand and cyclically compressed. Peak strain was then measured by Speckle Tracking Ultrasound and sonomicrometry. Results We succeeded in automating the acquisition and analysis of sample data. Sample data was collected at a rate of 200 measurement pairs in 30 minutes. We found good agreement between Speckle Tracking Ultrasound and sonomicrometry in the in vitro model. Best agreement was 0.83 ± 0.70%. Worst agreement was -1.13 ± 6.46%. Conclusions It has been shown possible to automate a model that can be used for evaluating the in vitro accuracy and precision of ultrasound modalities measuring deformation. Sonomicrometry and Speckle Tracking Ultrasound had acceptable agreement. PMID:20822532
van de Water, A T M; Benjamin, D R
2016-02-01
Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.
Calibration and Evaluation of Ultrasound Thermography using Infrared Imaging
Hsiao, Yi-Sing; Deng, Cheri X.
2015-01-01
Real-time monitoring of the spatiotemporal evolution of tissue temperature is important to ensure safe and effective treatment in thermal therapies including hyperthermia and thermal ablation. Ultrasound thermography has been proposed as a non-invasive technique for temperature measurement, and accurate calibration of the temperature-dependent ultrasound signal changes against temperature is required. Here we report a method that uses infrared (IR) thermography for calibration and validation of ultrasound thermography. Using phantoms and cardiac tissue specimens subjected to high-intensity focused ultrasound (HIFU) heating, we simultaneously acquired ultrasound and IR imaging data from the same surface plane of a sample. The commonly used echo time shift-based method was chosen to compute ultrasound thermometry. We first correlated the ultrasound echo time shifts with IR-measured temperatures for material-dependent calibration and found that the calibration coefficient was positive for fat-mimicking phantom (1.49 ± 0.27) but negative for tissue-mimicking phantom (− 0.59 ± 0.08) and cardiac tissue (− 0.69 ± 0.18 °C-mm/ns). We then obtained the estimation error of the ultrasound thermometry by comparing against the IR measured temperature and revealed that the error increased with decreased size of the heated region. Consistent with previous findings, the echo time shifts were no longer linearly dependent on temperature beyond 45 – 50 °C in cardiac tissues. Unlike previous studies where thermocouples or water-bath techniques were used to evaluate the performance of ultrasound thermography, our results show that high resolution IR thermography provides a useful tool that can be applied to evaluate and understand the limitations of ultrasound thermography methods. PMID:26547634
Wang, Siyou; Zhang, Shujing
2012-11-01
Study Type - Diagnostic (case series) Level of Evidence 4. What's known on the subject? and What does the study add? Pelvic floor muscle training (PFMT) and transvaginal electrical stimulation (TES) are two commonly used forms of conservative treatment for stress urinary incontinence (SUI). PFMT may build up the structural support of the pelvis, but many SUI patients are unable to perform PFMT effectively and its primary disadvantage is lack of long-term patient compliance. TES is a passive treatment that produces PFM contraction and patient compliance with it is good; however, its effect is not as good as that of PFMT when performed correctly. Electrical pudendal nerve stimulation (EPNS) combines the advantages of PFMT and TES and incorporates the technique of deep insertion of long needles. In this study, simultaneous perineal ultrasound and vaginal pressure measurement prove that EPNS can contract the PFM and simulate PFMT. It is shown that EPNS is an alternative therapy for female SUI patients who fail PFMT and TES and the therapy can also be used for severe SUI. • To prove that electrical pudendal nerve stimulation (EPNS) can contract the pelvic floor muscles (PFM) and simulate pelvic floor muscle training (PFMT). • To show that EPNS is an alternative therapy for female stress urinary incontinence (SUI) that does not respond effectively to PFMT and transvaginal electrical stimulation (TES). • Thirty-five female patients with SUI who did not respond effectively to PFMT and TES (group I) were enrolled and 60 other female patients with SUI were allocated to group II (30 patients) and group III (30 patients). • Long needles were deeply inserted into four sacral points and electrified to stimulate the pudendal nerves. Group I and group II were treated by a doctor skilled in performing EPNS and group III, by a doctor unskilled in performing EPNS. • When EPNS was performed in group I, perineal ultrasonographic PFM movements, vaginal pressure (VP) and PFM electromyography were recorded simultaneously. • The therapeutic effects were evaluated according to objective and subjective criteria • When EPNS was performed correctly, the patient felt strong PFM contractions. Simultaneous recordings in group I showed: B-mode cranio-caudal PFM movements; M-mode PFM movement curves (amplitude: about 1 mm, n= 31); a sawtooth curve of VP changes (2.61 ± 1.29 cmH(2) O, n= 34); and PFM myoelectric waves (amplitude: 23.9 ± 25.3 µV). • If during the EPNS process the electric current was stopped or its intensity was reduced to about 7-12 mA or the two lower needles were drawn back, then the above ultrasonographic PFM movements and VP changes disappeared. • In group I, the incontinence severity and quality of life score was 16.5 ± 4.0 before treatment and decreased to 4.2 ± 4.0 after 27.5 ± 11.9 sessions of treatment (P < 0.01). At the end of treatment, 100% improvement occurred in 16 cases (45.7%). A 2-year follow-up showed that 100% improvement occurred in 14 of cases (40.0%). • In group II, the incontinence severity and quality of life score was 17.1 ± 6.3 before treatment and decreased to 3.5 ± 3.7 after 10 sessions of treatment (P < 0.01) and 100% improvement occurred in 12 cases (40.0%). In group III, the incontinence severity and quality of life score was 17.6 ± 6.3 before treatment and decreased to 10.8 ± 8.2 after 10 sessions of treatment (P < 0.01) and 100% improvement occurred in one case (3.3%). • The post-treatment score was lower and the therapeutic effect was better in group II than in group III (both P < 0.01). • EPNS can contract the PFM and simulate PFMT. • EPNS is an alternative therapy for female SUI patients who fail PFMT and TES. © 2012 BJU INTERNATIONAL.
NASA Astrophysics Data System (ADS)
Laasanen, Mikko S.; Saarakkala, Simo; Töyräs, Juha; Rieppo, Jarno; Jurvelin, Jukka S.
2005-07-01
Previous quantitative 2D-ultrasound imaging studies have demonstrated that the ultrasound reflection measurement of articular cartilage surface sensitively detects degradation of the collagen network, whereas digestion of cartilage proteoglycans has no significant effect on the ultrasound reflection. In this study, the first aim was to characterize the ability of quantitative 2D-ultrasound imaging to detect site-specific differences in ultrasound reflection and backscattering properties of cartilage surface and cartilage-bone interface at visually healthy bovine knee (n = 30). As a second aim, we studied factors controlling ultrasound reflection properties of an intact cartilage surface. The ultrasound reflection coefficient was determined in time (R) and frequency domains (IRC) at medial femoral condyle, lateral patello-femoral groove, medial tibial plateau and patella using a 20 MHz ultrasound imaging instrument. Furthermore, cartilage surface roughness was quantified by calculating the ultrasound roughness index (URI). The superficial collagen content of the cartilage was determined using a FT-IRIS-technique. A significant site-dependent variation was shown in cartilage thickness, ultrasound reflection parameters, URI and superficial collagen content. As compared to R and IRC, URI was a more sensitive parameter in detecting differences between the measurement sites. Ultrasound reflection parameters were not significantly related to superficial collagen content, whereas the correlation between R and URI was high. Ultrasound reflection at the cartilage-bone interface showed insignificant site-dependent variation. The current results suggest that ultrasound reflection from the intact cartilage surface is mainly dependent on the cartilage surface roughness and the collagen content has a less significant role.
Endometrial thickness in 1,500 asymptomatic postmenopausal women not on hormone replacement therapy.
Hartman, Alex; Wolfman, Wendy; Nayot, Dan; Hartman, Michael
2013-01-01
To determine the normal endometrial thickness (ET) on transvaginal ultrasound (TVUS) of asymptomatic postmenopausal women not on hormone replacement therapy. A subgroup that was determined to be suspicious for having an endometrial polyp was compared with the remainder. This prospective study selected 1,500 consecutive asymptomatic postmenopausal women receiving TVUS assessment from January to August 2010. ET was recorded. Results were divided into those with a normal-appearing lining (n = 1,399) and those suspicious for polyp (n = 101). Results for the entire sample were obtained and the groups were compared using independent samples t tests. Of 1,500 women aged 45-95 years, 77.1% had an ET of ≤4 mm and 92% were ≤5 mm. Independent samples t tests were performed to compare the mean age and mean ET based on polyp status (i.e. with or without a possible polyp). There was a significant difference in mean age, 67.71 vs. 62.36 years (p < 0.01) and mean ET 8.02 vs. 3.40 mm (p < 0.01) between groups. 92% of asymptomatic postmenopausal women not on hormone replacement therapy had an ET of ≤5 mm. The mean ET was 3.71 ± 1.9 mm. However, a significant group, 6.7%, had an endometrial lining suspicious for polyp. These women had a significant increase in mean age and ET. Copyright © 2013 S. Karger AG, Basel.
Holdstock, J M; Dos Santos, S J; Harrison, C C; Price, B A; Whiteley, M S
2015-03-01
To determine the prevalence of haemorrhoids in women with pelvic vein reflux, identify which pelvic veins are associated with haemorrhoids and assess if extent of pelvic vein reflux influences the prevalence of haemorrhoids. Females presenting with leg varicose veins undergo duplex ultrasonography to assess all sources of venous reflux. Those with significant reflux arising from the pelvis are offered transvaginal duplex ultrasound (TVS) to evaluate reflux in the ovarian veins and internal Iliac veins and associated pelvic varices in the adnexa, vulvar/labial veins and haemorrhoids. Patterns and severity of reflux were evaluated. Between January 2010 and December 2012, 419 female patients with leg or vulvar varicose vein patterns arising from the pelvis underwent TVS. Haemorrhoids were identified on TVS via direct tributaries from the internal Iliac veins in 152/419 patients (36.3%) and absent in 267/419 (63.7%). The prevalence of the condition increased with the number of pelvic trunks involved. There is a strong association between haemorrhoids and internal Iliac vein reflux. Untreated reflux may be a cause of subsequent symptomatic haemorrhoids. Treatment with methods proven to work in conditions caused by pelvic vein incompetence, such as pelvic vein embolisation and foam sclerotherapy, could be considered. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Marcelin, C; Izaaryene, J; Castelli, M; Barral, P A; Jacquier, A; Vidal, V; Bartoli, J M
2017-12-01
To evaluate the safety and efficacy of pelvic embolization using ethylene vinyl alcohol copolymer (Onyx ® ) for pelvic congestion syndrome. Between March 2012 to September 2016, 17 women (mean age, 44.7± 12.2 (SD) years; range: 34-71years) presenting with pelvic congestion syndrome were evaluated for transvenous embolization with Onyx ® . Pelvic congestion syndrome was initially diagnosed by clinical examination and the results of transvaginal Doppler ultrasound and further confirmed by pelvic venography. Primary and secondary clinical efficacy was defined respectively by the resolution of the symptoms after embolization and at the end of the follow-up, irrespective to the number of embolization procedures. Technical efficacy of embolization was 100% with no significant complications during and after embolization. After a mean follow-up time of 24.2 months (range: 6-69months) a primary and secondary clinical efficacy of 76.4% (13/17 women) and 94.1% (16/17 women) respectively were observed. Four women (23.5%) underwent a second embolization procedure with one woman requiring a third embolization procedure. These additional embolization procedures were associated with direct puncture of vulvar varices for sclerotherapy in two women. Five women (29%) had recurrent symptoms 21 months post-treatment (7-42months). Pelvic embolization using ethylene vinyl alcohol copolymer (Onyx ® ) has a favorable clinical success for pelvic congestion syndrome. Copyright © 2017. Published by Elsevier Masson SAS.
Yan, Lei; Ding, Lingling; Li, Chunyan; Wang, Yu; Tang, Rong; Chen, Zi-Jiang
2014-03-01
To investigate the effect of fibroids that do not distort the endometrial cavity on IVF/intracytoplasmic sperm injection (ICSI) outcomes and to identify certain fibroid subgroups that may be deleterious to fertility outcomes. Retrospective cohort study. University-based reproductive medicine center. A total of 10,268 patients undergoing IVF/ICSI between 2009 and 2011 in our unit. Transvaginal ultrasound and hysteroscopy; controlled ovarian hyperstimulation and IVF/ICSI; strict matching criteria. Cycle cancellation, clinical pregnancy, miscarriage, and delivery rates. We included 249 patients with fibroids who underwent IVF/ICSI. Higher day 3 FSH levels were found in women with fibroids compared with in control subjects. No significant differences were found in IVF/ICSI outcomes between the two groups. Patients with intramural fibroids with the largest diameter <2.85 cm or the sum of reported diameters <2.95 cm had a significantly higher delivery rate than patients with larger fibroids. A significant negative effect on delivery rate was noted when intramural fibroids with the largest diameter greater than 2.85 cm were considered, compared with matched controls without fibroids. Our results suggest that although non-cavity-distorting fibroids do not affect IVF/ICSI outcomes, intramural fibroids greater than 2.85 cm in size significantly impair the delivery rate of patients undergoing IVF/ICSI. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Andrade, Carla Maria Araujo; Araujo Júnior, Edward; Torloni, Maria Regina; Moron, Antonio Fernandes; Guazzelli, Cristina Aparecida Falbo
2016-02-01
To compare the rates of success of two-dimensional (2D) and three-dimensional (3D) sonographic (US) examinations in locating and adequately visualizing levonorgestrel intrauterine devices (IUDs) and to explore factors associated with the unsuccessful viewing on 2D US. Transvaginal 2D and 3D US examinations were performed on all patients 1 month after insertion of levonorgestrel IUDs. The devices were considered adequately visualized on 2D US if both the vertical (shadow, upper and lower extremities) and the horizontal (two echogenic lines) shafts were identified. 3D volumes were also captured to assess the location of levonorgestrel IUDs on 3D US. Thirty women were included. The rates of adequate device visualization were 40% on 2D US (95% confidence interval [CI], 24.6; 57.7) and 100% on 3D US (95% CI, 88.6; 100.0). The device was not adequately visualized in all six women who had a retroflexed uterus, but it was adequately visualized in 12 of the 24 women (50%) who had a nonretroflexed uterus (95% CI, -68.6; -6.8). We found that 3D US is better than 2D US for locating and adequately visualizing levonorgestrel IUDs. Other well-designed studies with adequate power should be conducted to confirm this finding. © 2015 Wiley Periodicals, Inc.
Three-dimensional imaging of the brain cavities in human embryos.
Blaas, H G; Eik-Nes, S H; Kiserud, T; Berg, S; Angelsen, B; Olstad, B
1995-04-01
A system for high-resolution three-dimensional imaging of small structures has been developed, based on the Vingmed CFM-800 annular array sector scanner with a 7.5-MHz transducer attached to a PC-based TomTec Echo-Scan unit. A stepper motor rotates the transducer 180 degrees and the complete three-dimensional scan consists of 132 two-dimensional images, video-grabbed and scan-converted into a regular volumetric data set by the TomTec unit. Three normal pregnancies with embryos of gestational age 7, 9 and 10 weeks received a transvaginal examination with special attention to the embryonic/fetal brain. In all three cases, it was possible to obtain high-resolution images of the brain cavities. At 7 weeks, both hemispheres and their connection to the third ventricle were delineated. The isthmus rhombencephali could be visualized. At 9 weeks, the continuous development of the brain cavities could be followed and at 11 weeks the dominating size of the hemispheres could be depicted. It is concluded that present ultrasound technology has reached a stage where structures of only a few millimeters can be imaged in vivo in three-dimensions with a quality that resembles the plaster figures used in embryonic laboratories. The method can become an important tool in future embryological research and also in the detection of early developmental disorders of the embryo.
Possible non-sexual modes of transmission of human papilloma virus.
Sabeena, Sasidharanpillai; Bhat, Parvati; Kamath, Veena; Arunkumar, Govindakarnavar
2017-03-01
There is strong evidence to suggest vertical and horizontal modes of transmission of human papilloma virus (HPV), an established etiologic agent of cervical cancer. Infants, children, and adults can acquire both high-risk and low-risk infections by birth or by close contact even though HPV is mainly transmitted sexually. A thorough review of the literature was performed to assess the possible non-sexual modes of transmission of HPV. An electronic search of databases for review articles, cross-sectional studies, cohort studies, and case reports on non-sexual modes of transmission among sexually unexposed women and children was carried out using search terms such as "human papilloma virus, HPV, transmission, horizontal transmission, vertical transmission, and fomites". Articles published between 1983 and 2015 were retrieved. Epidemiological and clinical data support various non-sexual modes of transmission especially at the time of birth and by close contact. Even though the role of fomites in the transmission of HPV is not well established, HPV-DNA positivity has been reported in transvaginal ultrasound probes and colposcopes after routine disinfection. Awareness needs to be spread among the public about alternate modes of transmission. For a proper understanding of the exact natural history of HPV infection acquired via the non-sexual route, long-term prospective studies need to be undertaken. © 2017 Japan Society of Obstetrics and Gynecology.
Silva, Rita Oliveira da; Gomes, Mariano Tamura Vieira; Castro, Rodrigo de Aquino; Bonduki, Cláudio Emílio; Girão, Manoel João Batista Castello
2016-10-01
Purpose To translate into Portuguese, culturally adapt and validate the Uterine Fibroid Symptom - Quality of Life (UFS-QoL) questionnaire for Brazilian women with uterine leiomyoma. Methods Initially, the UFS-QoL questionnaire was translated into Brazilian Portuguese in accordance with international standards, with subsequent cultural, structural, conceptual and semantic adaptations, so that patients were able to properly answer the questionnaire. Fifty patients with uterine leiomyoma and 19 patients without the disease, confirmed by abdominal pelvic examination and/or transvaginal ultrasound, were selected at the outpatient clinics of the Department of Gynecology of the Universidade Federal de São Paulo (Unifesp). The UFS-QoL questionnaire was administered to all women twice on the same day, with two different interviewers, with an interval of 15 minutes between interviews. After 15 days, the questionnaire was re-administered by the first interviewer. Reliability (internal consistency and test-retest), construct and discriminative validity were tested to ratify the questionnaire. Results The reliability of the instrument was assessed by Cronbach's α coefficient with an overall result of 0.97, indicating high reliability. The survey results showed a high correlation ( p = 0.94; p ≤ 0.001). Conclusion The UFS-QoL questionnaire was successfully adapted to the Brazilian Portuguese language and Brazilian culture, showing reliability and validity. Thieme Publicações Ltda Rio de Janeiro, Brazil.
Eriksen, Mette B; Brusgaard, Klaus; Andersen, Marianne; Tan, Qihua; Altinok, Magda L; Gaster, Michael; Glintborg, Dorte
2012-07-01
Polycystic ovary syndrome (PCOS) is the most common endocrine disease among premenopausal women. A recent study found association between three single nucleotide polymorphisms (SNPs) and PCOS in a cohort of Han Chinese women. To investigate the association between rs13405728 (LHCGR gene), rs13429458 (THADA gene) and rs2479106 (DENND1A gene), PCOS, hirsutism and metabolic and hormonal parameters in a well characterized cohort of Caucasian patients of Danish descendant with PCOS or hirsutism. Patients underwent clinical examination, hormone analyses, oral glucose tolerance test and transvaginal ultrasound. Genetic variation was tested using allelic discrimination by real-time PCR. 268 patients referred to The Department of Endocrinology, Odense University Hospital, Denmark with PCOS or hirsutism between 1997 and 2011. Two hundred and forty-eight healthy females were included as controls. Genotype distributions and allele frequencies of rs13405728, rs13429458, and rs2479106 were comparable in patients and controls. The rs2479106 G allele was associated with a decreased PCOS susceptibility. None of the SNPs were associated with hirsutism or increased metabolic parameters. The rs2479106 G allele was associated with decreased PCOS susceptibility, thus confirming previously reported findings of association between rs2479106 and PCOS. Metabolic and hormonal parameters were comparable between genotypes of rs13405728 and rs2479106. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
[Different patterns of follicular development and luteal function].
Gu, L; Zhang, L; Gu, F
1995-09-01
To study the relationship between luteal function and different patterns of follicular development. Different patterns of follicular development as observed under transvaginal B-ultrasound in 85 infertile patients included: (1) Ovulation from normal follicle (ONF). (2) Ovulation from two follicles at the same cycle (O2F). (3) Ovulation from small follicle (OSF). (4) Ovulation from polycystic ovaries (PCO). (5) Luteinized unruptured follicle syndrome (LUFS). (6) Anovulation with follicular atresia. The luteal function of the first 5 types was evaluated by serum and peritoneal fluid estrogen, progesterone levels, endometrial histology, estradiol receptor (ER) and progesterone receptor (PR) analyaes, and the length of luteal phase. The incidence of luteal phase deficiency (LPD): short luteal phase was 10.42%, retardation of endometrial development was 4.17% in ONF, no LPD in O2F, 21.42% in OSF, 2/3 in PCO, 3/6 in LUFS, respectively. The incidence of LPD was 14.58% in ONF, 56.52% in abnormal follicular development groups (OSF, O2F and LUFS) (P < 0.005). It was found that the retardation of endometrial development was associated either with lowered serum P level or normal serum P but lowered ER and PR concentrations. The latter condition was recognized as "pseudocorpus luteum deficiency". The different patterns of follicular development may exert a great influence over luteal function through the different production of steroid hormones and their receptors.
Short and inflamed cervix predicts spontaneous preterm birth (COLIBRI study).
Raiche, Evelyne; Ouellet, Annie; Berthiaume, Maryse; Rousseau, Éric; Pasquier, Jean-Charles
2014-07-01
To develop a new strategy of predicting spontaneous preterm birth (sPTB) by combination of transvaginal ultrasound (TVUS) assessment and inflammatory proteins detection in vaginal secretions. Prospective study of 87 women referred for cervical length assessment with a standardized TVUS combined to vaginal secretions sampling. Samples were analyzed for presence of 10 cytokines. Main outcome was sPTB (<37 weeks of gestation). Associations were assessed with the chi-square, Fisher's exact test (p < 0.05) and Wald's logistic regression. sPTB occurred in 25.3% of women at a median gestational age of 35.6 weeks of gestation. Short cervix (<25 mm) (n = 24) was associated with sPTB (p < 0.01) as interleukine (IL)-1β, IL-8 and IL-10 in vaginal secretions (p < 0.05). In multivariate analysis, short cervix and IL-8 in vaginal secretions were independently associated with sPTB (OR 3.58 (95%CI 1.02; 12.61) and 14.55 (95%CI 1.64; 128.83), respectively) as their combination (OR 4.33 (95%CI 1.25; 14.95)). By categorizing cervical length by presence of IL-8, sPTB occurred in 55.6% of women with a short inflamed cervix. COLIBRI study used a novel, single-step method of vaginal secretions sampling during TVUS and demonstrated that combination of short cervix and IL-8 in vaginal secretions is a promising sPTB predictive test.
NASA Astrophysics Data System (ADS)
Kim, Younsu; Kim, Sungmin; Boctor, Emad M.
2017-03-01
An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.
Siahmed, K; Berges, O; Desjardins, L; Lumbroso, L; Brasseur, G
2004-02-01
Detail the role of different imaging techniques for diagnosis of tumors of the iris. Sixty-one tumors of the iris were explored using ultrasound at 10 and 20MHz (Cinescan, BVI Quantel Medical) and 50MHz (UBM, Paradigm) and optical coherence tomography (OCT) (Humphrey Zeiss). Ultrasound should be used at frequencies of 20MHz or greater to precisely characterize, localize and measure a lesion. Ultrasound biomicroscopy (UBM) is inadequate to measure large tumors (extending toward the back of the ciliary body), because of the transducer and the considerably lower image quality caused by the lesion. Ultrasound alone cannot characterize a solid lesion, and moreover cannot differentiate benign and malignant lesions. Clinical notions are also important in diagnosis and patient management. OCT recognizes whether a lesion is liquid or solid in certain cases. With a tumor that seems solid, a 50MHz examination must be done rapidly, and if the entire lesion is difficult to see, a 20MHz ultrasound should be used. With a protruding iris, high-frequency ultrasound and OCT differentiate a cystic lesion from a solid mass, but only BMU provides a precise measurement and regular surveillance capabilities.
Simons, M; Kee, E Gee; Kimble, R; Tyack, Z
2017-08-01
The aim of this study was to investigate the reproducibility and validity of measuring scar height in children using ultrasound and 3D camera. Using a cross-sectional design, children with discrete burn scars were included. Reproducibility was tested using Intraclass Correlation Coefficient (ICC) for reliability, and percentage agreement within 1mm between test and re-test, standard error of measurement (SEM), smallest detectable change (SDC) and Bland Altman limits of agreement for agreement. Concurrent validity was tested using Spearman's rho for support of pre-specified hypotheses. Forty-nine participants (55 scars) were included. For ultrasound, test-retest and inter-rater reproducibility of scar thickness was acceptable for scarred skin (ICC=0.95, SDC=0.06cm and ICC=0.82, SDC=0.14cm). The ultrasound picked up changes of <1mm. Inter-rater reproducibility of maximal scar height using the 3D camera was acceptable (ICC=0.73, SDC=0.55cm). Construct validity of the ultrasound was supported with a strong correlation between the measure of scar thickness and observer ratings of thickness using the POSAS (ρ=0.61). Construct validity of the 3D camera was also supported with a moderate correlation (ρ=0.37) with the same measure using maximal scar height. The ultrasound is capable of detecting smaller changes or differences in scar thickness than the 3D camera, in children with burn scars. However agreement as part of reproducibility was lower than expected between raters for the ultrasound. Improving the accuracy of scar relocation may go some way to address agreement. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Improvement of Shear Wave Motion Detection Using Harmonic Imaging in Healthy Human Liver.
Amador, Carolina; Song, Pengfei; Meixner, Duane D; Chen, Shigao; Urban, Matthew W
2016-05-01
Quantification of liver elasticity is a major application of shear wave elasticity imaging (SWEI) to non-invasive assessment of liver fibrosis stages. SWEI measurements can be highly affected by ultrasound image quality. Ultrasound harmonic imaging has exhibited a significant improvement in ultrasound image quality as well as for SWEI measurements. This was previously illustrated in cardiac SWEI. The purpose of this study was to evaluate liver shear wave particle displacement detection and shear wave velocity (SWV) measurements with fundamental and filter-based harmonic ultrasound imaging. In a cohort of 17 patients with no history of liver disease, a 2.9-fold increase in maximum shear wave displacement, a 0.11 m/s decrease in the overall interquartile range and median SWV and a 17.6% increase in the success rate of SWV measurements were obtained when filter-based harmonic imaging was used instead of fundamental imaging. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging
Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E.
2013-01-01
A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts. PMID:22042148
Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona
2010-12-01
To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.
Ceramic membrane ultrafiltration of natural surface water with ultrasound enhanced backwashing.
Boley, A; Narasimhan, K; Kieninger, M; Müller, W-R
2010-01-01
Ultrafiltration membrane cleaning with ultrasound enhanced backwashing was investigated with two ceramic membrane systems in parallel. One of them was subjected to ultrasound during backwashing, the other acted as a reference system. The feed water was directly taken from a creek with a sedimentation process as only pre-treatment. The cleaning performance was improved with ultrasound but after 3 weeks of operation damages occurred on the membranes. These effects were studied with online measurements of flux, trans-membrane-pressure and temperature, but also with integrity tests, turbidity measurements and visual examination.
Biliary lithotripsy can be enhanced with proper ultrasound probe position.
Affronti, J; Flournoy, T; Akers, S; Baillie, J
1992-04-01
We have demonstrated in our in vitro system that an extracorporeal lithotripter utilizing a movable ultrasound probe can fragment gallstones more effectively when the ultrasound probe is not partially blocking shock waves. Using a pressure transducer we measured the pressures in the focal volume of a Wolf Piezolith 2300 lithotripter with the ultrasound probe fully extended and fully retracted. We also chose 12 pairs of twin gallstones, each taken from the same gallbladder. One stone from each pair was subjected to shock waves while the ultrasound probe was fully extended and the other treated while the probe was fully retracted. Shock wave pressures (which are converted to a measurable voltage output by our transducer) were clearly lower when the ultrasound probe was extended (5.45 volts; SEM = 0.10 volts) as compared to when the ultrasound scanner was retracted (6.7 volts: SEM = 0.08 volts). Significantly more shock waves were required to completely fragment stones when the ultrasound scanner was extended than when it was retracted (p = 0.01 using the nonparametric Wilcoxon's signed rank test). These results show that, in the lithotripter tested, an extended in-line ultrasound scanner can partially block shock waves. Retraction of an extendible ultrasound probe may enhance stone fragmentation when operating at the highest shock wave intensity.
Miyamoto, Naokazu; Hirata, Kosuke; Kanehisa, Hiroaki; Yoshitake, Yasuhide
2015-01-01
Ultrasound shear wave elastography is becoming a valuable tool for measuring mechanical properties of individual muscles. Since ultrasound shear wave elastography measures shear modulus along the principal axis of the probe (i.e., along the transverse axis of the imaging plane), the measured shear modulus most accurately represents the mechanical property of the muscle along the fascicle direction when the probe's principal axis is parallel to the fascicle direction in the plane of the ultrasound image. However, it is unclear how the measured shear modulus is affected by the probe angle relative to the fascicle direction in the same plane. The purpose of the present study was therefore to examine whether the angle between the principal axis of the probe and the fascicle direction in the same plane affects the measured shear modulus. Shear modulus in seven specially-designed tissue-mimicking phantoms, and in eleven human in-vivo biceps brachii and medial gastrocnemius were determined by using ultrasound shear wave elastography. The probe was positioned parallel or 20° obliquely to the fascicle across the B-mode images. The reproducibility of shear modulus measurements was high for both parallel and oblique conditions. Although there was a significant effect of the probe angle relative to the fascicle on the shear modulus in human experiment, the magnitude was negligibly small. These findings indicate that the ultrasound shear wave elastography is a valid tool for evaluating the mechanical property of pennate muscles along the fascicle direction.
Whole breast tissue characterization with ultrasound tomography
NASA Astrophysics Data System (ADS)
Duric, Neb; Littrup, Peter; Li, Cuiping; Roy, Olivier; Schmidt, Steve; Seamans, John; Wallen, Andrea; Bey-Knight, Lisa
2015-03-01
A number of clinical trials have shown that screening ultrasound, supplemental to mammography, detects additional cancers in women with dense breasts. However, labor intensity, operator dependence and high recall rates have limited adoption. This paper describes the use of ultrasound tomography for whole-breast tissue stiffness measurements as a first step toward addressing the issue of high recall rates. The validation of the technique using an anthropomorphic phantom is described. In-vivo applications are demonstrated on 13 breast masses, indicating that lesion stiffness correlates with lesion type as expected. Comparison of lesion stiffness measurements with standard elastography was available for 11 masses and showed a strong correlation between the 2 measures. It is concluded that ultrasound tomography can map out the 3 dimensional distribution of tissue stiffness over the whole breast. Such a capability is well suited for screening where additional characterization may improve the specificity of screening ultrasound, thereby lowering barriers to acceptance.
Quantitative muscle ultrasound and quadriceps strength in patients with post-polio syndrome.
Bickerstaffe, Alice; Beelen, Anita; Zwarts, Machiel J; Nollet, Frans; van Dijk, Johannes P
2015-01-01
We investigated whether muscle ultrasound can distinguish muscles affected by post-polio syndrome (PPS) from healthy muscles and whether severity of ultrasound abnormalities is associated with muscle strength. Echo intensity, muscle thickness, and isometric strength of the quadriceps muscles were measured in 48 patients with PPS and 12 healthy controls. Patients with PPS had significantly higher echo intensity and lower muscle thickness than healthy controls. In patients, both echo intensity and muscle thickness were associated independently with muscle strength. A combined measure of echo intensity and muscle thickness was more strongly related to muscle strength than either parameter alone. Quantitative ultrasound distinguishes healthy muscles from those affected by PPS, and measures of muscle quality and quantity are associated with muscle strength. Hence, ultrasound could be a useful tool for assessing disease severity and monitoring changes resulting from disease progression or clinical intervention in patients with PPS. © 2014 Wiley Periodicals, Inc.
Falou, Omar; Rui, Min; El Kaffas, Ahmed; Kumaradas, J Carl; Kolios, Michael C
2010-08-01
The measurement of the ultrasound backscatter from individual micron-sized objects such as cells is required for various applications such as tissue characterization. However, performing such a measurement remains a challenge. For example, the presence of air bubbles in a suspension of cells during the measurements may lead to the incorrect interpretation of the acoustic signals. This work introduces a technique for measuring the ultrasound backscatter from individual micron-sized objects by combining a microinjection system with a co-registered optical microscope and an ultrasound imaging device. This allowed the measurement of the ultrasound backscatter response from a single object under optical microscope guidance. The optical and ultrasonic data were used to determine the size of the object and to deduce its backscatter responses, respectively. In order to calibrate the system, the backscatter frequency responses from polystyrene microspheres were measured and compared to theoretical predictions. A very good agreement was found between the measured backscatter responses of individual microspheres and theoretical predictions of an elastic sphere. The backscatter responses from single OCI-AML-5 cells were also investigated. It was found that the backscatter responses from AML cells are best modeled using the fluid sphere model. The advantages, limitations, and future applications of the developed technique are discussed.
Hematuria and clot retention after transvaginal oocyte aspiration: a case report.
Modder, Joshua; Kettel, L Michael; Sakamoto, Kyoko
2006-09-01
To report a case of bladder injury with hematuria and urinary retention after transvaginal oocyte aspiration. Case report. Emergency room in a university medical center. A 28-year-old woman presented with urinary retention and suprapubic pain 8 hours after oocyte aspiration. Foley catheter, intravenous fluid bolus, bladder irrigation, and computed tomography with postvoid films that showed a blood clot in the bladder. Patient was discharged home with antibiotics and catheter in place. Clinical follow-up. Patient passed voiding trial 4 days later and was artificially inseminated. No further hematuria or voiding problems were reported, and she had a successful pregnancy. Patients who elect to undergo oocyte aspiration should be warned about the possibility of bladder injury because of the close proximity of the ovaries to the bladder, and physicians should have an appropriate treatment plan.
Sulak, Patricia J; Smith, Virginia; Coffee, Andrea; Witt, Iris; Kuehl, Alicia L; Kuehl, Thomas J
2008-09-01
To assess bleeding patterns with continuous use of the transvaginal contraceptive ring. We did a prospective analysis of daily menstrual flow during a 21/7 cycle followed by 6 months of continuous use and institution of a randomized protocol to manage breakthrough bleeding/spotting. Seventy-four women completed the baseline 21/7 phase and were randomized equally into two groups during the continuous phase. Group 1 was instructed to replace the ring monthly on the same calendar day with no ring-free days. Group 2 was instructed to use the same process, but if breakthrough bleeding/spotting occurred for 5 days or more, they were to remove the ring for 4 days, store it, and then reinsert that ring. Sixty-five women completed the continuous phase with reduced average flow scores in the continuous phase compared with the 21/7 phase (P<.02). Most patients had no to minimal bleeding during continuous use, with group 2 experiencing a statistically greater percentage of days without breakthrough bleeding or spotting (95%) compared with group 1 (89%) (P=.016). Instituting a 4-day hormone-free interval was more (P<.001) effective in resolving breakthrough bleeding/spotting than continuing ring use. A reduction in bleeding occurred during continuous use with replacement of the transvaginal ring compared with baseline 21/7 use. Continuous vaginal ring use resulted in an acceptable bleeding profile in most patients, reduction in flow, reduction in pelvic pain, and a high continuation rate.
Two-port robotic hysterectomy: a novel approach.
Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi
2018-03-24
The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.
Karl, Stephan; Li Wai Suen, Connie S N; Unger, Holger W; Ome-Kaius, Maria; Mola, Glen; White, Lisa; Wangnapi, Regina A; Rogerson, Stephen J; Mueller, Ivo
2015-01-01
Knowledge of accurate gestational age is required for comprehensive pregnancy care and is an essential component of research evaluating causes of preterm birth. In industrialised countries gestational age is determined with the help of fetal biometry in early pregnancy. Lack of ultrasound and late presentation to antenatal clinic limits this practice in low-resource settings. Instead, clinical estimators of gestational age are used, but their accuracy remains a matter of debate. In a cohort of 688 singleton pregnancies from rural Papua New Guinea, delivery gestational age was calculated from Ballard score, last menstrual period, symphysis-pubis fundal height at first visit and quickening as well as mid- and late pregnancy fetal biometry. Published models using sequential fundal height measurements and corrected last menstrual period to estimate gestational age were also tested. Novel linear models that combined clinical measurements for gestational age estimation were developed. Predictions were compared with the reference early pregnancy ultrasound (<25 gestational weeks) using correlation, regression and Bland-Altman analyses and ranked for their capability to predict preterm birth using the harmonic mean of recall and precision (F-measure). Average bias between reference ultrasound and clinical methods ranged from 0-11 days (95% confidence levels: 14-42 days). Preterm birth was best predicted by mid-pregnancy ultrasound (F-measure: 0.72), and neuromuscular Ballard score provided the least reliable preterm birth prediction (F-measure: 0.17). The best clinical methods to predict gestational age and preterm birth were last menstrual period and fundal height (F-measures 0.35). A linear model combining both measures improved prediction of preterm birth (F-measure: 0.58). Estimation of gestational age without ultrasound is prone to significant error. In the absence of ultrasound facilities, last menstrual period and fundal height are among the more reliable clinical measures. This study underlines the importance of strengthening ultrasound facilities and developing novel ways to estimate gestational age.
Effect of dissolved oxygen level of water on ultrasonic power measured using calorimetry
NASA Astrophysics Data System (ADS)
Uchida, Takeyoshi; Yoshioka, Masahiro; Horiuchi, Ryuzo
2018-07-01
Ultrasonic therapeutic equipment, which exposes the human body to high-power ultrasound, is used in clinical practice to treat cancer. However, the safety of high-power ultrasound has been questioned because the equipment affects not only cancer cells but also normal cells. To evaluate the safety of ultrasound, it is necessary to accurately measure the ultrasonic power of the equipment. This is because ultrasonic power is a key quantity related to the thermal hazard of ultrasound. However, precise techniques for measuring ultrasonic power in excess of 15 W are yet to be established. We have been studying calorimetry as a precise measurement technique. In this study, we investigated the effect of the dissolved oxygen (DO) level of water on ultrasonic power by calorimetry. The results show that the measured ultrasonic power differed significantly between water samples of different DO levels. This difference in ultrasonic power arose from acoustic cavitation.
Monitoring of Lactic Fermentation Process by Ultrasonic Technique
NASA Astrophysics Data System (ADS)
Alouache, B.; Touat, A.; Boutkedjirt, T.; Bennamane, A.
The non-destructive control by using ultrasound techniques has become of great importance in food industry. In this work, Ultrasound has been used for quality control and monitoring the fermentation stages of yogurt, which is a highly consumed product. On the contrary to the physico-chemical methods, where the measurement instruments are directly introduced in the sample, ultrasound techniques have the advantage of being non-destructive and contactless, thus reducing the risk of contamination. Results obtained in this study by using ultrasound seem to be in good agreement with those obtained by physico-chemical methods such as acidity measurement by using a PH-meter instrument. This lets us to conclude that ultrasound method may be an alternative for a healthy control of yoghurt fermentation process.
Sharma, Kaveri; Venkatesh, B.P; Barman, Partho; Roy, Sumit Kumar; Jayagurunathan, Usha; Sellamuthu, Eswaramoorthy; Moidu, Fazil
2015-01-01
Introduction Adenomyosis and Leiomyoma are common disorders affecting females in their reproductive age. They mimic each other in clinical presentation. Due to similarities in clinical symptoms and signs, missing one diagnosis in favour of the other is not very uncommon. Accurate diagnosis of these two conditions is important for their management. In this study we evaluated role of 3D Ultrasound and Doppler in differentiating clinically suspected cases of leiomyoma and adenomyosis of uterus. Materials and Methods A total of 100 patients with symptoms of abnormal uterine bleeding (with or without dysmenorrhoea), lump abdomen, chronic pelvic pain or dysparaunia who were clinically diagnosed as leiomyoma of uterus and/or adenomyosis were enrolled in to the study. These patients underwent transvaginal sonography (TVS), trans abdominal sonography (TAS) along with color and spectral Doppler sonography. Scanning was done in follicular phase of the menstrual cycle to avoid bias due high vascularity of endometrium in secretory phase. The morphology of the lesion, its vascularity, and Pulsality Index (PI), Resistive Index (RI) and Vmax (maximum velocity) were measured. Only those patients who were chosen for operative treatment were included in the study. Radiological diagnosis was then correlated with intra-operative and histopathological diagnosis. Results On imaging, while using morphological criteria and Doppler for diagnosing leiomyoma, it was found that “peripheral vascularity” was seen in 52 (89%) cases, which was the highest. Similarly while diagnosing adenomyosis it was, the criteria “central vascularity” was seen in 28 cases (93%) and “ill defined junctional zone in 3D ultrasound” was seen in 26 cases (86%), which was also observed to be highest. With the cut off values taken for PI,RI and Vmax, diagnosis of leiomyoma was found to be 93.4% sensitive, 95.6% specific and with a positive predictive value of 97.6% and negative predictive value of 88.6%. Diagnosis of adenomyosis showed a sensitivity of 95.6%, specificity of 93.4% and a positive predictive value of 88.6% and negative predictive value of 97.6%. Imaging dignosed the co-existence of both the conditions correctly in 8 (66%) cases. Conclusion The parameters of blood flow impedance (that is PI, RI, and Vmax) of arteries within or around the uterine lesions revealed a consistent and significant difference between leiomyoma and adenomyosis. So apart from morphological criteria used in 3D TAS and TVS, aid of color Doppler can more accurately differentiate and diagnose these conditions. PMID:26023602
Lim, Audrey J R; Huang, Zhongwei; Chua, Seok Eng; Kramer, Michael S; Yong, Eu-Leong
2016-01-01
Few studies have examined the associations between sleep duration, shiftwork, and exercise to the infrequent menstruation, hyperandrogenism, and ovarian morphological changes observed in women with polycystic ovarian syndrome (PCOS). To examine whether lifestyle factors, including short sleep duration, insufficient exercise, and shiftwork, alone or in combination, are associated with the reproductive and metabolic abnormalities typical of PCOS in a healthy population. Prospective cross-sectional study of 231 women, including healthcare workers recruited for an annual health screen, healthy referral patients from the Women's Clinic and volunteers from the university community at the National University Hospital, Singapore, from 2011 to 2015. The women completed a questionnaire, including their menstrual cycle length, sleep length, frequency of exercise and shift work. Hyperandrogenism (hirsutism score, testosterone, sex hormone binding globulin (SHBG)), ovarian morphology and function (anthral follicle count, ovarian volume, anti-mullerian hormone (AMH)), and metabolic measures (body mass index (BMI), waist hip ratio (WHR), blood pressure, fasting glucose, fasting insulin and fasting lipids) were examined through anthropometric measurements, transvaginal ultrasound scans, and blood tests. No significant associations were observed between shift work, exercise or sleep duration and the androgenic and ovarian measures that define PCOS. However, women reporting fewer than 6 hours of sleep were more likely to report abnormal (short or long) menstrual cycle lengths (OR = 2.1; 95% CI, 1.1 to 4.2). Women who reported fewer than 6 hours of sleep had increased fasting insulin levels (difference in means = 2.13; 95% CI, 0.27 to 3.99 mU/L) and higher odds of insulin resistance (OR = 2.58; CI, 1.16 to 5.76). Lack of regular exercise was associated with higher mean fasting insulin (difference in means = 2.3 mU/L; 95% CI, 0.5 to 4.1) and HOMA-IR (difference in means = 0.49; 95% CI, 0.09 to 0.90) levels. Women with insufficient sleep are at increased risk of menstrual disturbances and insulin resistance, but do not have the hyperandrogenism and polycystic ovarian morphology typical of PCOS. Improved sleep duration may help reduce the risks of diabetes or infertility. Shift work, exercise or sleep duration appear not to impact the androgenic and ovarian measures that define PCOS.
Nondestructive evaluation of hydrogel mechanical properties using ultrasound
Walker, Jason M.; Myers, Ashley M.; Schluchter, Mark D.; Goldberg, Victor M.; Caplan, Arnold I.; Berilla, Jim A.; Mansour, Joseph M.; Welter, Jean F.
2012-01-01
The feasibility of using ultrasound technology as a noninvasive, nondestructive method for evaluating the mechanical properties of engineered weight-bearing tissues was evaluated. A fixture was designed to accurately and reproducibly position the ultrasound transducer normal to the test sample surface. Agarose hydrogels were used as phantoms for cartilage to explore the feasibility of establishing correlations between ultrasound measurements and commonly used mechanical tissue assessments. The hydrogels were fabricated in 1–10% concentrations with a 2–10 mm thickness. For each concentration and thickness, six samples were created, for a total of 216 gel samples. Speed of sound was determined from the time difference between peak reflections and the known height of each sample. Modulus was computed from the speed of sound using elastic and poroelastic models. All ultrasonic measurements were made using a 15 MHz ultrasound transducer. The elastic modulus was also determined for each sample from a mechanical unconfined compression test. Analytical comparison and statistical analysis of ultrasound and mechanical testing data was carried out. A correlation between estimates of compressive modulus from ultrasonic and mechanical measurements was found, but the correlation depended on the model used to estimate the modulus from ultrasonic measurements. A stronger correlation with mechanical measurements was found using the poroelastic rather than the elastic model. Results from this preliminary testing will be used to guide further studies of native and engineered cartilage. PMID:21773854
Accurate prediction of pregnancy viability by means of a simple scoring system.
Bottomley, Cecilia; Van Belle, Vanya; Kirk, Emma; Van Huffel, Sabine; Timmerman, Dirk; Bourne, Tom
2013-01-01
What is the performance of a simple scoring system to predict whether women will have an ongoing viable intrauterine pregnancy beyond the first trimester? A simple scoring system using demographic and initial ultrasound variables accurately predicts pregnancy viability beyond the first trimester with an area under the curve (AUC) in a receiver operating characteristic curve of 0.924 [95% confidence interval (CI) 0.900-0.947] on an independent test set. Individual demographic and ultrasound factors, such as maternal age, vaginal bleeding and gestational sac size, are strong predictors of miscarriage. Previous mathematical models have combined individual risk factors with reasonable performance. A simple scoring system derived from a mathematical model that can be easily implemented in clinical practice has not previously been described for the prediction of ongoing viability. This was a prospective observational study in a single early pregnancy assessment centre during a 9-month period. A cohort of 1881 consecutive women undergoing transvaginal ultrasound scan at a gestational age <84 days were included. Women were excluded if the first trimester outcome was not known. Demographic features, symptoms and ultrasound variables were tested for their influence on ongoing viability. Logistic regression was used to determine the influence on first trimester viability from demographics and symptoms alone, ultrasound findings alone and then from all the variables combined. Each model was developed on a training data set, and a simple scoring system was derived from this. This scoring system was tested on an independent test data set. The final outcome based on a total of 1435 participants was an ongoing viable pregnancy in 885 (61.7%) and early pregnancy loss in 550 (38.3%) women. The scoring system using significant demographic variables alone (maternal age and amount of bleeding) to predict ongoing viability gave an AUC of 0.724 (95% CI = 0.692-0.756) in the training set and 0.729 (95% CI = 0.684-0.774) in the test set. The scoring system using significant ultrasound variables alone (mean gestation sac diameter, mean yolk sac diameter and the presence of fetal heart beat) gave an AUC of 0.873 (95% CI = 0.850-0.897) and 0.900 (95% CI = 0.871-0.928) in the training and the test sets, respectively. The final scoring system using demographic and ultrasound variables together gave an AUC of 0.901 (95% CI = 0.881-0.920) and 0.924 (CI = 0.900-0.947) in the training and the test sets, respectively. After defining the cut-off at which the sensitivity is 0.90 on the training set, this model performed with a sensitivity of 0.92, specificity of 0.73, positive predictive value of 84.7% and negative predictive value of 85.4% in the test set. BMI and smoking variables were a potential omission in the data collection and might further improve the model performance if included. A further limitation is the absence of information on either bleeding or pain in 18% of women. Caution should be exercised before implementation of this scoring system prior to further external validation studies This simple scoring system incorporates readily available data that are routinely collected in clinical practice and does not rely on complex data entry. As such it could, unlike most mathematical models, be easily incorporated into normal early pregnancy care, where women may appreciate an individualized calculation of the likelihood of ongoing pregnancy viability. Research by V.V.B. supported by Research Council KUL: GOA MaNet, PFV/10/002 (OPTEC), several PhD/postdoc & fellow grants; IWT: TBM070706-IOTA3, PhD Grants; IBBT; Belgian Federal Science Policy Office: IUAP P7/(DYSCO, `Dynamical systems, control and optimization', 2012-2017). T.B. is supported by the Imperial Healthcare NHS Trust NIHR Biomedical Research Centre. Not applicable.
Examples of Radiation-Emitting Products
... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...
Acoustic holography as a metrological tool for characterizing medical ultrasound sources and fields
Sapozhnikov, Oleg A.; Tsysar, Sergey A.; Khokhlova, Vera A.; Kreider, Wayne
2015-01-01
Acoustic holography is a powerful technique for characterizing ultrasound sources and the fields they radiate, with the ability to quantify source vibrations and reduce the number of required measurements. These capabilities are increasingly appealing for meeting measurement standards in medical ultrasound; however, associated uncertainties have not been investigated systematically. Here errors associated with holographic representations of a linear, continuous-wave ultrasound field are studied. To facilitate the analysis, error metrics are defined explicitly, and a detailed description of a holography formulation based on the Rayleigh integral is provided. Errors are evaluated both for simulations of a typical therapeutic ultrasound source and for physical experiments with three different ultrasound sources. Simulated experiments explore sampling errors introduced by the use of a finite number of measurements, geometric uncertainties in the actual positions of acquired measurements, and uncertainties in the properties of the propagation medium. Results demonstrate the theoretical feasibility of keeping errors less than about 1%. Typical errors in physical experiments were somewhat larger, on the order of a few percent; comparison with simulations provides specific guidelines for improving the experimental implementation to reduce these errors. Overall, results suggest that holography can be implemented successfully as a metrological tool with small, quantifiable errors. PMID:26428789
Knapp, Karen
2013-01-01
Assessment of diagnostic image quality in gynaecological ultrasound is an important aspect of imaging department quality assurance. This may be addressed through audit, but who should undertake the audit, what should be measured and how, remains contentious. The aim of this study was to identify whether peer audit is a suitable method of assessing the diagnostic quality of gynaecological ultrasound images. Nineteen gynaecological ultrasound studies were independently assessed by six sonographers utilising a pilot version of an audit tool. Outcome measures were levels of inter-rater agreement using different data collection methods (binary scores, Likert scale, continuous scale), effect of ultrasound study difficulty on study score and whether systematic differences were present between reviewers of different clinical grades and length of experience. Inter-rater agreement ranged from moderate to good depending on the data collection method. A continuous scale gave the highest level of inter-rater agreement with an intra-class correlation coefficient of 0.73. A strong correlation (r = 0.89) between study difficulty and study score was yielded. Length of clinical experience between reviewers had no effect on the audit scores, but individuals of a higher clinical grade gave significantly lower scores than those of a lower grade (p = 0.04). Peer audit is a promising tool in the assessment of ultrasound image quality. Continuous scales seem to be the best method of data collection implying a strong element of heuristically driven decision making by reviewing ultrasound practitioners. PMID:27433192
Ultrasound measures of tendon thickness: Intra-rater, Inter-rater and Inter-machine reliability.
Del Baño-Aledo, María Elena; Martínez-Payá, Jacinto Javier; Ríos-Díaz, José; Mejías-Suárez, Silvia; Serrano-Carmona, Sergio; de Groot-Ferrando, Ana
2017-01-01
Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. III.
Harris, Heather S; Benson, Scott R; James, Michael C; Martin, Kelly J; Stacy, Brian A; Daoust, Pierre-Yves; Rist, Paul M; Work, Thierry M; Balazs, George H; Seminoff, Jeffrey A
2016-03-01
Leatherback turtles (Dermochelys coriacea) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45-90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.
Assessment of Spectral Doppler in Preclinical Ultrasound Using a Small-Size Rotating Phantom
Yang, Xin; Sun, Chao; Anderson, Tom; Moran, Carmel M.; Hadoke, Patrick W.F.; Gray, Gillian A.; Hoskins, Peter R.
2013-01-01
Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°–80°. However, for angles of 10°–40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound. PMID:23711503
Harris, Heather S.; Benson, Scott R.; James, Michael C.; Martin, Kelly J.; Stacy, Brian A.; Daoust, Pierre-Yves; Rist, Paul M.; Work, Thierry M.; Balazs, George H.; Seminoff, Jeffrey A.
2016-01-01
Leatherback turtles (Dermochelys coriacea) undergo substantial cyclical changes in body condition between foraging and nesting. Ultrasonography has been used to measure subcutaneous fat as an indicator of body condition in many species but has not been applied in sea turtles. To validate this technique in leatherback turtles, ultrasound images were obtained from 36 live-captured and dead-stranded immature and adult turtles from foraging and nesting areas in the Pacific and Atlantic oceans. Ultrasound measurements were compared with direct measurements from surgical biopsy or necropsy. Tissue architecture was confirmed histologically in a subset of turtles. The dorsal shoulder region provided the best site for differentiation of tissues. Maximum fat depth values with the front flipper in a neutral (45–90°) position demonstrated good correlation with direct measurements. Ultrasound-derived fat measurements may be used in the future for quantitative assessment of body condition as an index of health in this critically endangered species.
Pfeiffer, P; Rudolph, S S; Børglum, J; Isbye, D L
2011-11-01
This study compared the time consumption of bilateral lung ultrasound with auscultation and capnography for verifying endotracheal intubation. A prospective, paired, and investigator-blinded study carried out in the operating theatre. Twenty-five adult patients requiring endotracheal intubation were included. During intubation, transtracheal ultrasound was performed to visualize passage of the endotracheal tube. During bag ventilation, bilateral lung ultrasound was performed for the detection of lung sliding as a sign of ventilation simultaneous with capnography and auscultation of the epigastrium and chest. Primary outcome measure was time difference to confirmed endotracheal intubation between ultrasound and auscultation alone. Secondary outcome measure was time difference between ultrasound and auscultation combined with capnography. Both methods verified endotracheal tube placement in all patients. In 68% of patients, endotracheal tube placement was visualized by real-time transtracheal ultrasound. Comparing ultrasound with the combination of auscultation and capnography, there was a significant difference between the two methods. Median time for ultrasound was 40 s [interquartile range (IQR) 35-48 s] vs. 48 s (IQR 45-53 s), P < 0.0001. Mean difference was -7.1 s in favour of ultrasound [95% confidence interval (CI) -9.4--4.8 s]. No significant difference was found between ultrasound compared with auscultation alone. Median time for auscultation alone was 42 s (IQR 37-47 s), P = 0.6, with a mean difference of -0.88 s in favour of ultrasound (95% CI -4.2-2.5 s). Verification of endotracheal tube placement with ultrasound is as fast as auscultation alone and faster than the standard method of auscultation and capnography. © 2011 The Authors. Acta Anaesthesiologica Scandinavica © 2011 The Acta Anaesthesiologica Scandinavica Foundation.
Ophthalmic applications of laser-generated ultrasound
NASA Astrophysics Data System (ADS)
Payne, Peter A.; Sadr, Ali; Rosen, Emanuel S.; Dewhurst, Richard J.
2000-06-01
Laser-generated ultrasound has found a number of niche applications in non-destructive testing and evaluation and there is now a growing trend to examine potential applications for materials characterization in medicine. Conventional ultrasound techniques for measuring various important dimensions within the eye are in extensive use. However, one problem remains outstanding, which is that the dimensions of the cornea, anterior chamber and lens can be measured using a high frequency, high resolution transducer, but the dimensions of the overall eyeball (i.e., cornea to retina) have to be measured with a lower frequency transducer in order to achieve the necessary penetration. We have conducted a number of in vitro studies using bovine eyes to determine whether the use of laser induced ultrasound would be able to overcome the aforementioned problem. The results of these measurements will be presented, together with a discussion of the many difficulties that remain to be overcome. In addition, our studies involve the potential use of laser ultrasound to quantify the degree of cataract formation, both primary and secondary. This paper will also consider the work accomplished to data in this area.
Apoptosis Induction in Cancer Cells by Ultrasound Exposure
NASA Astrophysics Data System (ADS)
Watanabe, Akihiro; Kawai, Kazuaki; Sato, Toshio; Nishimura, Hiroyuki; Kawashima, Norimichi; Takeuchi, Shinichi
2004-05-01
The methods of suppressing cancer cell proliferation by ultrasound exposure were investigated to develop a new minimally invasive cancer treatment. A stainless-steel diaphragm with a bolt-clamped Langevin-type transducer (BLT) was attached to the bottom of a water tank in the ultrasound exposure system used in this study. Cancer cells of a mouse T lymphoma (EL-4) in a flask were exposed to ultrasound under various conditions of exposure time, ultrasound frequency, ultrasound waveform, and so forth. The number of cancer cells exposed to ultrasound decreased during the culturing process. In this study, it was proved by electrophoresis, enzyme activity measurement and morphological observation that cancer cell proliferation can be suppressed by apoptosis induction in cancer cells by ultrasound exposure.
Lee, Sun Jin; Chong, Semin; Kang, Kyung Ho; Hur, Joonho; Hong, Byung-Woo; Kim, Hyun Jung; Kim, Soo Jin
2014-11-01
The objective of our study was to measure thyroid volumes using semiautomated 3D CT and to compare the 3D CT volumes with volumes measured using 2D ultrasound, 2D CT, and the water displacement method. In 47 patients, 2D ultrasound volumes and 2D CT volumes of the thyroid gland were estimated using the ellipsoid volume formula, and 3D CT volumes were calculated using semiautomated reconstructive techniques. All volume data were compared with thyroid specimen volumes obtained using the water displacement method and were statistically analyzed using the one-way ANOVA, the Pearson correlation coefficient (R), linear regression, and the concordance correlation coefficient (CCC). The processing time of semiautomated 3D CT thyroid volumetry was measured. The paired mean differences ± SD between the three imaging-determined volumes and the specimen volumes were 0.8 ± 3.1 mL for 2D ultrasound, 4.0 ± 4.7 mL for 2D CT, and 0.2 ± 2.5 mL for 3D CT. A significant difference in the mean thyroid volume was found between 2D CT and specimen volumes (p = 0.016) compared with the other pairs (p = 0.937 for 2D ultrasound mean volume vs specimen mean volume, and p = 0.999 for 3D CT mean volume vs specimen mean volume). Between specimen volume and 2D ultrasound volume, specimen volume and 2D CT volume, and specimen volume and 3D CT volume, R values were 0.885, 0.724, and 0.929, respectively, and CCC values were 0.876, 0.598, and 0.925, respectively. The mean processing time of semiautomated 3D CT thyroid volumetry was 7.0 minutes. Thyroid volumes measured using 2D ultrasound or semiautomated 3D CT are substantially close to thyroid specimen volumes measured using the water displacement method. Semiautomated 3D CT thyroid volumetry can provide a more reliable measure of thyroid volume than 2D ultrasound.
Pysz, Marybeth A.; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K.
2015-01-01
Purpose To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. Materials and methods The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. Results MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Conclusion Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts. PMID:22535383
Pysz, Marybeth A; Guracar, Ismayil; Foygel, Kira; Tian, Lu; Willmann, Jürgen K
2012-09-01
To develop and test a real-time motion compensation algorithm for contrast-enhanced ultrasound imaging of tumor angiogenesis on a clinical ultrasound system. The Administrative Institutional Panel on Laboratory Animal Care approved all experiments. A new motion correction algorithm measuring the sum of absolute differences in pixel displacements within a designated tracking box was implemented in a clinical ultrasound machine. In vivo angiogenesis measurements (expressed as percent contrast area) with and without motion compensated maximum intensity persistence (MIP) ultrasound imaging were analyzed in human colon cancer xenografts (n = 64) in mice. Differences in MIP ultrasound imaging signal with and without motion compensation were compared and correlated with displacements in x- and y-directions. The algorithm was tested in an additional twelve colon cancer xenograft-bearing mice with (n = 6) and without (n = 6) anti-vascular therapy (ASA-404). In vivo MIP percent contrast area measurements were quantitatively correlated with ex vivo microvessel density (MVD) analysis. MIP percent contrast area was significantly different (P < 0.001) with and without motion compensation. Differences in percent contrast area correlated significantly (P < 0.001) with x- and y-displacements. MIP percent contrast area measurements were more reproducible with motion compensation (ICC = 0.69) than without (ICC = 0.51) on two consecutive ultrasound scans. Following anti-vascular therapy, motion-compensated MIP percent contrast area significantly (P = 0.03) decreased by 39.4 ± 14.6 % compared to non-treated mice and correlated well with ex vivo MVD analysis (Rho = 0.70; P = 0.05). Real-time motion-compensated MIP ultrasound imaging allows reliable and accurate quantification and monitoring of angiogenesis in tumors exposed to breathing-induced motion artifacts.
The use of three-dimensional ultrasound does not improve training in fetal biometric measurements.
Chan, Lin W; Ting, Yuen H; Lao, Terence T; Chau, Macy M C; Fung, Tak Y; Leung, Tak Y; Sahota, Daljit S; Lau, Tze K
2011-09-01
To investigate whether three-dimensional (3D) technology offers any advantage over two-dimensional (2D) ultrasound in fetal biometric measurement training. Ten midwives with no hands-on experience in ultrasound were randomized to receive training on 2D or 3D ultrasound fetal biometry assessment. Midwives were taught how to obtain fetal biometric measurements (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL)) by a trainer. Subsequently, each midwife measured the parameters on another 10 fetuses. The same set of measurements was repeated by the trainer. The percentage deviation between the midwives' and the trainer's measurements was determined and compared between training groups. Time required for completion was recorded. Frozen images were reviewed by another sonographer to assess the image quality using a standardized scoring system. The median time for the complete set of measurements was significantly shorter in the 2D than in 3D group (13.4 min versus 17.8 min, P = 0.03). The mean percentage deviations did not reach statistical significance between the two groups except for FL (3.83% in 2D group versus 2.23% in 3D group (P = 0.046)). There were no significant differences in the quality scores. This study showed that the only demonstrable advantage of 3D ultrasound was a slightly more accurate measurement of FL, at the expense of a significantly longer time required.
Notter, D R; Mousel, M R; Leeds, T D; Zerby, H N; Moeller, S J; Lewis, G S; Taylor, J B
2014-06-01
Use of lamb BW or chilled carcass weights (CCW), live-animal ultrasound or direct carcass measurements of backfat thickness (BF; mm) and LM area (LMA; cm(2)), and carcass body wall thickness (BWall; mm) to predict carcass yield and value was evaluated using 512 crossbred lambs produced over 3 yr by mating Columbia, U.S. Meat Animal Research Center Composite, Suffolk, and Texel rams to adult Rambouillet ewes. Lambs were harvested at 3 BW endpoints within each year. The predictive value of 3 to 5 additional linear measurements of live-animal or carcass size and shape was also evaluated. Residual correlations (adjusted for effects of year, breed, and harvest group) between ultrasound and direct measurements were 0.69 for BF and 0.65 for LMA. Increasing ultrasound or carcass LMA had positive effects (P < 0.001) on yield of chilled carcass (i.e., on dressing percentage) and, at comparable CCW, on weight of high-value cuts (rack, loin, leg, and sirloin) before trimming (HVW), weight of trimmed high-value cuts (trimmed rack and loin and trimmed boneless leg and sirloin; TrHVW), and carcass value before (CVal) and after (TrCVal) trimming of high-value cuts. By contrast, ultrasound and direct measures of BF had positive effects on yields of CCW and on HVW and CVal but large negative effects on TrHVW and TrCVal. After adjusting for BW at scanning, increases of 1 mm in ultrasound BF or 1 cm(2) in ultrasound LMA were associated with changes of US$-0.32 (P < 0.10) and $1.62 (P < 0.001), respectively, in TrCVal. Carcass BWall was generally superior to carcass BF as a predictor of TrHVW and TrCVal. Carcass LMA was superior to ultrasound LMA but carcass BF was inferior to ultrasound BF for prediction of carcass yield and value. Increasing LMA thus would be expected to improve carcass yield and value. Addition of linear measurements of live-animal or carcass size and shape to the prediction model reduced residual SD (RSD) for TrHVW and TrCVal by 0.4 to 2.2%, but subsequent removal of ultrasound or direct measures of BF and LMA from the prediction model increased RSD by 7.4 to 12.2%. Measurements of CCW, LMA, BF, and BWall would thus be appropriate to support programs for value-based marketing of lamb carcasses and are superior to systems based only on measurements of size and shape in unribbed carcasses.
Surgical removal of a large vaginal calculus formed after a tension-free vaginal tape procedure.
Zilberlicht, Ariel; Feiner, Benjamin; Haya, Nir; Auslender, Ron; Abramov, Yoram
2016-11-01
Vaginal calculus is a rare disorder which has been reported in association with urethral diverticulum, urogenital sinus anomaly, bladder exstrophy and the tension-free vaginal tape (TVT) procedure. We report a 42-year-old woman who presented with persistent, intractable urinary tract infection (UTI) following a TVT procedure. Cystoscopy demonstrated an eroded tape with the formation of a bladder calculus, and the patient underwent laser cystolithotripsy and cystoscopic resection of the tape. Following this procedure, her UTI completely resolved and she remained asymptomatic for several years. Seven years later she presented with a solid vaginal mass. Pelvic examination followed by transvaginal ultrasonography and magnetic resonance imaging demonstrated a large vaginal calculus located at the lower third of the anterior vaginal wall adjacent to the bladder neck. This video presents the transvaginal excision and removal of the vaginal calculus.
Manual B-mode versus automated radio-frequency carotid intima-media thickness measurements.
Dogan, Soner; Plantinga, Yvonne; Dijk, Joke M; van der Graaf, Yolanda; Grobbee, Diederick E; Bots, Michiel L
2009-10-01
Carotid intima-media thickness (CIMT) serves as an indicator of atherosclerosis and cardiovascular risk. Manual measurements of B-mode ultrasound images are the most applied method. Automated measurements with radiofrequency (RF) ultrasound have been suggested as an alternative. The aim of this study was to compare these methods in terms of risk-factor relations and associations with future events. Data from participants of the Second Manifestations of Arterial Disease (SMART) study were used. Far wall common CIMT was measured online with manual B-mode and automated RF ultrasound. Measurements were performed by a group of 6 sonographers. Risk-factor information was obtained. All participants were followed for the occurrence of vascular events (mean follow-up, 2.1 years). CIMT was related to risk factors with linear regression models and to future events with Cox proportional-hazards models. Data were available for 2,146 participants. Agreement between the methods was modest (intraclass correlation coefficient = 0.34). Risk-factor relations with age and systolic blood pressure were stronger for B-mode than for RF ultrasound. Association with future events was better for B-mode than for RF ultrasound (vascular death, 1.27 vs 1.00; ischemic stroke, 1.45 vs 1.03). In participants with CIMT < 0.9 mm (without plaque), the intraclass correlation between the measures was 0.50. In addition, in that subgroup, RF ultrasound showed a stronger association with future events than B-mode ultrasound (all events, 1.59 vs 1.09; vascular death, 1.72 vs 0.93; coronary ischemic events, 1.65 vs 1.05). The preference for either B-mode or RF measurements may be driven by the type of study population, the expected presence of local atherosclerotic abnormalities, and the main aim of the study (assessing risk factors or events). However, in this study, as in many others, the B-mode approach was shown to be robust in risk-factor relations and the prediction of events.
Comparison of postoperative refractive outcomes: IOLMaster® versus immersion ultrasound.
Whang, Woong-Joo; Jung, Byung-Ju; Oh, Tae-Hoon; Byun, Yong-Soo; Joo, Choun-Ki
2012-01-01
To compare the postoperative refractive outcomes between IOLMaster biometry (Carl Zeiss Meditec, Inc., Dublin, CA) and immersion ultrasound biometry for axial length measurements. Refractive outcomes in 354 eyes were compared using the IOLMaster and the immersion ultrasound biometry. Predicted refraction was determined using manual keratometry and the SRK-T formula with personalized A-constant. The axial lengths measured using the IOLMaster and immersion ultrasound were 24.49 ± 2.11 and 24.46 ± 2.11 mm, respectively, and the difference was significant (P < .05). The mean errors were 0.000 ± 0.578 D with the IOLMaster, and 0.000 ± 0.599 D with the immersion ultrasound, but the difference was not significant. The mean absolute error was smaller with the IOLMaster than with immersion ultrasound (0.463 ± 0.341 vs 0.479 ± 0.359 D), but the difference was not significant. IOLMaster biometry yields highly accurate results in cataract surgery. However, if the IOLMaster is unavailable, immersion ultrasound biometry with personalized intraocular lens constants is an acceptable alternative. Copyright 2012, SLACK Incorporated.
Air-coupled ultrasound stimulated optical vibrometry for resonance analysis of rubber tubes
Zhang, Xiaoming; Kinnick, Randall R.; Greenleaf, James F.
2008-01-01
Air-coupled ultrasound stimulated optical vibrometry is proposed to generate and detect the resonances of a rubber tube in air. Amplitude-modulated (AM) focused ultrasound radiation force from a broadband air-coupled ultrasound transducer with center frequency of 500 kHz is used to generate a low frequency vibration in the tube. The resonances of several modes of the tube are measured with a laser vibrometer of 633 nm wavelength. A wave propagation approach is used to calculate the resonances of the tube from its known material properties. Theoretical and experimental resonance frequencies agree within 5%. This method may be useful in measuring the in vitro elastic properties of arteries from the resonance measurements in air. It may also be helpful in better understanding the coupling effects of surrounding tissue and interior blood on the vessel wall by measuring the resonance of the vessel in vitro and in vivo. PMID:18499208
Air-coupled ultrasound stimulated optical vibrometry for resonance analysis of rubber tubes.
Zhang, Xiaoming; Kinnick, Randall R; Greenleaf, James F
2009-01-01
Air-coupled ultrasound stimulated optical vibrometry is proposed to generate and detect the resonances of a rubber tube in air. Amplitude-modulated (AM) focused ultrasound radiation force from a broadband air-coupled ultrasound transducer with center frequency of 500 kHz is used to generate a low frequency vibration in the tube. The resonances of several modes of the tube are measured with a laser vibrometer of 633 nm wavelength. A wave propagation approach is used to calculate the resonances of the tube from its known material properties. Theoretical and experimental resonance frequencies agree within 5%. This method may be useful in measuring the in vitro elastic properties of arteries from the resonance measurements in air. It may also be helpful to better understand the coupling effects of the surrounding tissue and interior blood on the vessel wall by measuring the resonance of the vessel in vitro and in vivo.
Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure
NASA Astrophysics Data System (ADS)
Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit
2009-05-01
Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.
Renaud, Guillaume; Bosch, Johan G; Van Der Steen, Antonius F W; De Jong, Nico
2014-06-01
Contrast-enhanced ultrasound imaging is based on the detection of non-linear vibrational responses of a contrast agent after its intravenous administration. Improving contrast-enhanced images requires an accurate understanding of the vibrational response to ultrasound of the lipid-coated gas microbubbles that constitute most ultrasound contrast agents. Variations in the volume of microbubbles provide the most efficient radiation of ultrasound and, therefore, are the most important bubble vibrations for medical diagnostic ultrasound imaging. We developed an "acoustical camera" that measures the dynamic volume change of individual microbubbles when excited by a pressure wave. In the work described here, the technique was applied to the characterization of low-amplitude non-linear behaviors of BR14 microbubbles (Bracco Research, Geneva, Switzerland). The amplitude dependence of the resonance frequency and the damping, the prevalence of efficient subharmonic and ultraharmonic vibrations and the amplitude dependence of the response at the fundamental frequency and at the second harmonic frequency were investigated. Because of the large number of measurements, we provide a statistical characterization of the low-amplitude non-linear properties of the contrast agent. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Correlation between ultrasound velocity and densitometry in fresh and demineralized cortical bone
de Mesquita, Alessandro Queiroz; Barbieri, Giuliano; Barbieri, Claudio Henrique
2016-01-01
OBJECTIVE: To compare ultrasound propagation velocity with densitometry in the diaphyseal compact cortical bone of whole sheep metatarsals. METHODS: The transverse ultrasound velocity and bone mineral density of 5-cm-long diaphyseal bone segments were first measured. The bone segments were then divided into four groups of 15 segments each and demineralized in an aqueous 0.5 N hydrochloric acid solution for 6, 12, 24 or 36 hours. All measurements were repeated after demineralization for each time duration and the values measured before and after demineralization were compared. RESULTS: Ultrasound velocity and bone mineral density decreased with demineralization time, and most differences in the pre- and post-demineralization values within each group and between groups were significant: A moderate correlation coefficient (r=0.75956) together with a moderate agreement was determined between both post-demineralization parameters, detected by the Bland-Altman method. CONCLUSION: We conclude that both ultrasound velocity and bone mineral density decrease as a result of demineralization, thus indicating that bone mineral content is of great importance for maintaining the acoustic parameters of cortical bone, as observed for cancellous bone. Ultrasound velocity can be used to evaluate both compact cortical bone quality and bone mineral density. PMID:27982167
Correlation between ultrasound velocity and densitometry in fresh and demineralized cortical bone.
Mesquita, Alessandro Queiroz de; Barbieri, Giuliano; Barbieri, Claudio Henrique
2016-11-01
To compare ultrasound propagation velocity with densitometry in the diaphyseal compact cortical bone of whole sheep metatarsals. The transverse ultrasound velocity and bone mineral density of 5-cm-long diaphyseal bone segments were first measured. The bone segments were then divided into four groups of 15 segments each and demineralized in an aqueous 0.5 N hydrochloric acid solution for 6, 12, 24 or 36 hours. All measurements were repeated after demineralization for each time duration and the values measured before and after demineralization were compared. Ultrasound velocity and bone mineral density decreased with demineralization time, and most differences in the pre- and post-demineralization values within each group and between groups were significant: A moderate correlation coefficient (r=0.75956) together with a moderate agreement was determined between both post-demineralization parameters, detected by the Bland-Altman method. We conclude that both ultrasound velocity and bone mineral density decrease as a result of demineralization, thus indicating that bone mineral content is of great importance for maintaining the acoustic parameters of cortical bone, as observed for cancellous bone. Ultrasound velocity can be used to evaluate both compact cortical bone quality and bone mineral density.
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
Non-Contact Optical Ultrasound Concept for Biomedical Imaging
2016-11-03
Non -Contact Optical Ultrasound Concept for Biomedical Imaging Robert Haupt1, Charles Wynn1, Jonathan Fincke2, Shawn Zhang2, Brian Anthony2...results. Lastly, we present imaging capabilities using a non -contact laser ultrasound proof-of-concept system. Two and three dimensional time... non -contact, standoff optical ultrasound has the potential to provide a fixed reference measurement capability that minimizes operator variability as
The Use of B-Mode Ultrasound for Measuring Subcutaneous Fat Thickness on the Upper Arms.
ERIC Educational Resources Information Center
Weiss, Lawrence W.; Clark, Frank C.
1985-01-01
A study was carried out to investigate the potential use of B-mode ultrasound for measuring subcutaneous fat thickness at two arm sites. B-mode sonograms and skinfold measurements were found to be highly correlated for both men and women. (Author/MT)
Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study.
Chan, Hsun-Liang; Wang, Hom-Lay; Fowlkes, Jeffery Brian; Giannobile, William V; Kripfgans, Oliver D
2017-03-01
Ultrasound imaging has potential to complement radiographic imaging modalities in implant and oral surgery given that it is non-ionizing and provides instantaneous images of anatomical structures. For application in oral and dental imaging, its qualities are dependent on its ability to accurately capture these complex structures. Therefore, the aim of this feasibility study was to investigate ultrasound to image soft tissue, hard tissue surface topography and specific vital structures. A clinical ultrasound scanner, paired with two 14-MHz transducers of different sizes (one for extraoral and the other for intraoral scans), was used to scan the following structures on a fresh cadaver: (i) the facial bone surface and soft tissue of maxillary anterior teeth, (ii) the greater palatine foramen; (iii) the mental foramen and (iv) the lingual nerve. Multiple measurements relevant to these structures were made on the ultrasound images and compared to those on cone-beam computed tomography (CBCT) scans and/or direct measurements. Ultrasound imaging could delineate hard tissue surfaces, including enamel, root dentin and bone as well as soft tissue with high resolution (110 μm wavelength). The greater palatine foramen, mental foramen and lingual nerve were clearly shown in ultrasound images. Merging ultrasound and CBCT images demonstrated overall spatial accuracy of ultrasound images, which was corroborated by data gathered from direct measurements. For the first time, this study provides proof-of-concept evidence that ultrasound can be a real-time and non-invasive alternative for the evaluation of oral and dental anatomical structures relevant for implant and oral surgery. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Monau, Phetogo Ineeleng; Nsoso, Shalaulani James; Waugh, Esau Emmanuel; Sharma, Surender Pal
2013-03-01
The aim of this study was to characterise ultrasound measurements of live and carcass traits in intact males, females and castrated Tswana goat kids from birth to 12 months of age raised under semi-intensive system in South-eastern Botswana. Measurements were recorded in 15 castrates, 15 intact males and 15 female Tswana goat kids randomly selected at birth. Ultrasonic fat and muscle depths were measured at the first, third/fourth, sixth/seventh, ninth/tenth and 12th/13th thoracic; first, third and fifth lumbar and first, second/third and fourth/fifth sternal vertebrae, fortnightly for the first 6 months and then monthly for the remaining 6 months. The animals were stunned and humanely slaughtered at 12 months of age, and ultrasound and shatterproof ruler were used to measure fat and muscle depths on the carcasses at similar sites as on live animals. A real-time B-mode ultrasound scanner fitted with LV2-1 probe operating at 7.5 MHz (Explorer V5 Vet Laptop B-Ultrasonic Scanner UMC Technology Development Co., Ltd, China) was used to predict ultrasound measurements on live animals and their carcasses. Data were analysed using general linear model in statistical analysis system. Muscle depth measurements increased significantly (p < 0.05) with age in all sites of measurements. However, there was no significant difference between the sexes at different sites of muscle depth measurements at the same age. Muscle depth at the sternal vertebrae was significantly deeper (almost 55 mm at 12 months of age) than 16 mm at thoracic and 16 mm at lumbar vertebrae at 12 and 8 months of age, respectively. No subcutaneous fat depth measurements were recorded in the lumbar vertebrae (0.00 ± 0.00) and the thoracic (0.00 ± 0.00) regions in all sex groups. However, fourth and fifth sternal vertebrae showed considerably deeper amount of subcutaneous fat suitable for taking fat measurements as age increases (2.07 ± 0.23 mm females, 1.50 ± 0.43 mm intact males and 1.80 ± 0.38 mm castrates) at 12 months of age. All correlations between live and carcass ultrasound measurements and also between ultrasound carcass and ruler measurements were very high (r (2) = 0.96 to 1.00) for all the sexes indicating that live ultrasound measurements are suitable for use in this meat breed. More research is needed to evaluate the relationships between live ultrasonic measurements and carcass yield in the different sexes of Tswana goat kids.
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse.
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira; Horie, Shigeo
2018-03-01
This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP.
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse
Takazawa, Naoko; Fujisaki, Akiko; Yoshimura, Yasukuni; Tsujimura, Akira
2018-01-01
Purpose This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). Materials and Methods This retrospective cohort study involved 91 women who underwent surgical management of POP with originally designed small mesh between July 2014 and August 2015. This mesh is 56% smaller than the mesh widely used in Japan, and it has only two arms delivered into each right and left sacrospinous ligament. The main study outcome was the anatomic cure rate defined as recurrence of POP quantification (POP-Q) stage II or more. We also assessed changes in the overactive bladder symptom score (OABSS) and prolapse quality of life questionnaire (P-QOL) and evaluated adverse events. Finally, we compared patient backgrounds between the patients with and without recurrence. Results Prolapse recurred in 10 of 91 patients (11.0%), and all patients with recurrence were diagnosed as POP-Q stage II. As adverse events, only mesh erosion occurred in two (2.2%) and pelvic pain in one (1.1%) of the 91 patients. The OABSS and P-QOL were significantly improved by the operation. When we compared patient backgrounds between the patients with and without recurrence, body mass index was the only factor influencing affecting recurrence. Conclusions Transvaginal minimal mesh repair resulted in successful outcomes with low mesh-related complications and anatomic recurrence at one year. Furthermore, significant improvement in QOL was offered by this procedure. Our minimal mesh technique should be considered as one treatment option for the management of POP. PMID:29520390
Time-resolved flowmetering of gas-liquid two-phase pipe flow by ultrasound pulse Doppler method
NASA Astrophysics Data System (ADS)
Murai, Yuichi; Tasaka, Yuji; Takeda, Yasushi
2012-03-01
Ultrasound pulse Doppler method is applied for componential volumetric flow rate measurement in multiphase pipe flow consisted of gas and liquid phases. The flowmetering is realized with integration of measured velocity profile over the cross section of the pipe within liquid phase. Spatio-temporal position of interface is detected also with the same ultrasound pulse, which further gives cross sectional void fraction. A series of experimental demonstration was shown by applying this principle of measurement to air-water two-phase flow in a horizontal tube of 40 mm in diameter, of which void fraction ranges from 0 to 90% at superficial velocity from 0 to 15 m/s. The measurement accuracy is verified with a volumetric type flowmeter. We also analyze the accuracy of area integration of liquid velocity distribution for many different patterns of ultrasound measurement lines assigned on the cross section of the tube. The present method is also identified to be pulsation sensor of flow rate that fluctuates with complex gas-liquid interface behavior.
Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.
Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T
2013-04-01
Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Angtuaco, Teresita L; Hopkins, Robert H; DuBose, Terry J; Bursac, Zoran; Angtuaco, Michael J; Ferris, Ernest J
2007-06-01
This project was designed to test the feasibility of introducing ultrasound to senior medical students as a primary diagnostic tool in the evaluation of patients. Specifically, its aim was to determine if it is possible for medical students untrained in sonography to gain basic competence in performing abdominal ultrasound with limited didactic and hands-on instructions. Registered sonographers provided the students with hands-on instructions on the use of a compact ultrasound system. They were likewise shown how to evaluate specific organs and perform measurements. The results of the student measurements and those obtained by the sonographers were compared. There was close correlation between the results obtained by sonographers and students on both normal and abnormal findings. This supports the concept that medical students can be taught basic ultrasound skills with limited didactic and hands-on instructions with the potential of using these skills in the patient clinics as an adjunct to routine physical diagnosis.
van Dyk, Sylvia; Kondalsamy-Chennakesavan, Srinivas; Schneider, Michal; Bernshaw, David; Narayan, Kailash
2014-03-15
To compare measurements of the uterus and cervix obtained with magnetic resonance imaging (MRI) and transabdominal ultrasound to determine whether ultrasound can identify the brachytherapy target and be used to guide conformal brachytherapy planning and treatment for cervix cancer. Consecutive patients undergoing curative treatment with radiation therapy between January 2007 and March 2012 were included in the study. Intrauterine applicators were inserted into the uterine canal while patients were anesthetized. Images were obtained by MRI and transabdominal ultrasound in the longitudinal axis of the uterus with the applicator in treatment position. Measurements were taken at the anterior and posterior surface of the uterus at 2.0-cm intervals along the applicator, from the external os to the tip of the applicator. Data were analyzed using Bland Altman plots examining bias and 95% limits of agreement. A total of 192 patients contributed 1668 measurements of the cervix and uterus. Mean (± SD) differences of measurements between imaging modalities at the anterior and posterior uterine surface ranged from 1.5 (± 3.353) mm to 3.7 (± 3.856) mm, and -1.46 (± 3.308) mm to 0.47 (± 3.502) mm, respectively. The mean differences were less than 3 mm in the cervix. The mean differences were less than 1.5 mm at all measurement points on the posterior surface. Differences in the measurements of the cervix and uterus obtained by MRI and ultrasound were within clinically acceptable limits. Transabdominal ultrasound can be substituted for MRI in defining the target volume for conformal brachytherapy treatment of cervix cancer. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
Exploration Analysis of Carbon Dioxide Levels and Ultrasound Measures of the Eye During ISS Missions
NASA Technical Reports Server (NTRS)
Young, M.; Mason, S.; Schaefer, C.; Wear, M. L.; Sargsyan, A.; Garcia, K.; Coble, C.; Gruschkus, S.; Law, J.; Alexander, D.;
2016-01-01
Enhanced screening for the Visual Impairment/Intracranial Pressure (VIIP) Syndrome, including in-flight ultrasound, was implemented in 2010 to better characterize the changes in vision observed in some long-duration crewmembers. Suggested possible risk factors for VIIP include cardiovascular changes, diet, anatomical and genetic factors, and environmental conditions. As a potent vasodilator, carbon dioxide (CO (sub 2)), which is chronically elevated on the International Space Station (ISS) relative to typical indoor and outdoor ambient levels on Earth, seems a plausible contributor to VIIP. In an effort to understand the possible associations between CO (sub 2) and VIIP, this study analyzes the relationship between ambient CO (sub 2) levels on ISS and ultrasound measures of the eye obtained from ISS fliers. CO (sub 2) measurements will be pulled directly from Operational Data Reduction Complex for the Lab and Node 3 major constituent analyzers (MCAs) on ISS or from sensors located in the European Columbus module, as available. CO (sub 2) measures between ultrasound sessions will be summarized using standard time series class metrics in MATLAB including time-weighted means and variances. Cumulative CO (sub 2) exposure metrics will also be developed. Regression analyses will be used to quantify the relationships between the CO (sub 2) metrics and specific ultrasound measures. Generalized estimating equations will adjust for the repeated measures within individuals. Multiple imputation techniques will be used to adjust for any possible biases in missing data for either CO (sub 2) or ultrasound measures. These analyses will elucidate the possible relationship between CO (sub 2) and changes in vision and also inform future analysis of inflight VIIP data.
Yap, Timothy E; Archer, Timothy J; Gobbe, Marine; Reinstein, Dan Z
2016-02-01
To compare corneal thickness measurements between three imaging systems. In this retrospective study of 81 virgin and 58 post-laser refractive surgery corneas, central and minimum corneal thickness were measured using optical coherence tomography (OCT), very high-frequency digital ultrasound (VHF digital ultrasound), and a Scheimpflug imaging system. Agreement between methods was analyzed using mean differences (bias) (OCT - VHF digital ultrasound, OCT - Scheimpflug, VHF digital ultrasound - Scheimpflug) and Bland-Altman analysis with 95% limits of agreement (LoA). Virgin cornea mean central corneal thickness was 508.3 ± 33.2 µm (range: 434 to 588 µm) for OCT, 512.7 ± 32.2 µm (range: 440 to 587 µm) for VHF digital ultrasound, and 530.2 ± 32.6 µm (range: 463 to 612 µm) for Scheimpflug imaging. OCT and VHF digital ultrasound showed the closest agreement with a bias of -4.37 µm, 95% LoA ±12.6 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -21.9 µm, 95% LoA ±20.7 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -17.5 µm, 95% LoA ±19.0 µm. In post-laser refractive surgery corneas, mean central corneal thickness was 417.9 ± 47.1 µm (range: 342 to 557 µm) for OCT, 426.3 ± 47.1 µm (range: 363 to 563 µm) for VHF digital ultrasound, and 437.0 ± 48.5 µm (range: 359 to 571 µm) for Scheimpflug imaging. Closest agreement was between OCT and VHF digital ultrasound with a bias of -8.45 µm, 95% LoA ±13.2 µm. Least agreement was between OCT and Scheimpflug imaging with a bias of -19.2 µm, 95% LoA ±19.2 µm. Bias between VHF digital ultrasound and Scheimpflug imaging was -10.7 µm, 95% LoA ±20.0 µm. No relationship was observed between difference in central corneal thickness measurements and mean central corneal thickness. Results were similar for minimum corneal thickness. Central and minimum corneal thickness was measured thinnest by OCT and thickest by Scheimpflug imaging in both groups. A clinically significant bias existed between Scheimpflug imaging and the other two modalities. Copyright 2016, SLACK Incorporated.
Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H
2016-07-01
Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error in the velocity measurement of less than 10%. With the addition of cases with a range of pathologies, this duplex ultrasound simulator will be a useful tool for training health-care providers in vascular ultrasound applications and for assessing their skills in an objective and quantitative manner. © The Author(s) 2016.
Fetal head detection and measurement in ultrasound images by an iterative randomized Hough transform
NASA Astrophysics Data System (ADS)
Lu, Wei; Tan, Jinglu; Floyd, Randall C.
2004-05-01
This paper describes an automatic method for measuring the biparietal diameter (BPD) and head circumference (HC) in ultrasound fetal images. A total of 217 ultrasound images were segmented by using a K-Mean classifier, and the head skull was detected in 214 of the 217 cases by an iterative randomized Hough transform developed for detection of incomplete curves in images with strong noise without user intervention. The automatic measurements were compared with conventional manual measurements by sonographers and a trained panel. The inter-run variations and differences between the automatic and conventional measurements were small compared with published inter-observer variations. The results showed that the automated measurements were as reliable as the expert measurements and more consistent. This method has great potential in clinical applications.
A Preliminary Study on the Possibility of Using Ultrasound in Driver Assistance Systems
NASA Astrophysics Data System (ADS)
Takahashi, Hiroshi; Honda, Hirohiko
This paper presents a preliminary study on the possibility of using ultrasound in driver assistance systems. Subjects' lap time in a driving video game was measured as an index of their performance of driving operations under acoustic conditions with and without an ultrasound signal at 23kHz, 70dB. The results show that the performance characteristics of the subjects changed when the ultrasound signal was presented. Ultrasound signal tends to concentrate on handling the vehicle and decreasing an attention to check the over speed driving, as a second task. We prove the possibility to apply ultrasound signal to control operator's attention and behavior.
Anthropomorphic cardiac ultrasound phantom.
Smith, S W; Rinaldi, J E
1989-10-01
A new phantom is described which simulates the human cardiac anatomy for applications in ultrasound imaging, ultrasound Doppler, and color-flow Doppler imaging. The phantom consists of a polymer left ventricle which includes a prosthetic mitral and aortic valve and is connected to a mock circulatory loop. Aerated tap water serves as a blood simulating fluid and ultrasound contrast medium within the circulatory loop. The left ventricle is housed in a Lexan ultrasound visualization chamber which includes ultrasound viewing ports and acoustic absorbers. A piston pump connected to the visualization chamber by a single port pumps degassed water within the chamber which in turn pumps the left ventricle. Real-time ultrasound images and Doppler studies measure flow patterns through the valves and within the left ventricle.
Registration of surface structures using airborne focused ultrasound.
Sundström, N; Börjesson, P O; Holmer, N G; Olsson, L; Persson, H W
1991-01-01
A low-cost measuring system, based on a personal computer combined with standard equipment for complex measurements and signal processing, has been assembled. Such a system increases the possibilities for small hospitals and clinics to finance advanced measuring equipment. A description of equipment developed for airborne ultrasound together with a personal computer-based system for fast data acquisition and processing is given. Two air-adapted ultrasound transducers with high lateral resolution have been developed. Furthermore, a few results for fast and accurate estimation of signal arrival time are presented. The theoretical estimation models developed are applied to skin surface profile registrations.
Bryan, J.L.; Wildhaber, M.L.; Papoulias, D.M.; DeLonay, A.J.; Tillitt, D.E.; Annis, M.L.
2007-01-01
Most species of sturgeon are declining in the Mississippi River Basin of North America including pallid (Scaphirhynchus albus F. and R.) and shovelnose sturgeons (S. platorynchus R.). Understanding the reproductive cycle of sturgeon in the Mississippi River Basin is important in evaluating the status and viability of sturgeon populations. We used non-invasive, non-lethal methods for examining internal reproductive organs of shovelnose and pallid sturgeon. We used an ultrasound to measure egg diameter, fecundity, and gonad volume; endoscope was used to visually examine the gonad. We found the ultrasound to accurately measure the gonad volume, but it underestimated egg diameter by 52%. After correcting for the measurement error, the ultrasound accurately measured the gonad volume but it was higher than the true gonad volume for stages I and II. The ultrasound underestimated the fecundity of shovelnose sturgeon by 5%. The ultrasound fecundity was lower than the true fecundity for stage III and during August. Using the endoscope, we viewed seven different egg color categories. Using a model selection procedure, the presence of four egg categories correctly predicted the reproductive stage ± one reproductive stage of shovelnose sturgeon 95% of the time. For pallid sturgeon, the ultrasound overestimated the density of eggs by 49% and the endoscope was able to view eggs in 50% of the pallid sturgeon. Individually, the ultrasound and endoscope can be used to assess certain reproductive characteristics in sturgeon. The use of both methods at the same time can be complementary depending on the parameter measured. These methods can be used to track gonad characteristics, including measuring Gonadosomatic Index in individuals and/or populations through time, which can be very useful when associating gonad characteristics with environmental spawning triggers or with repeated examinations of individual fish throughout the reproductive cycle.
Developing an ultrasound correlation velocimetry system
NASA Astrophysics Data System (ADS)
Surup, Gerrit; White, Christopher; UNH Team
2011-11-01
The process of building an ultrasound correlation velocimetry (UCV) system by integrating a commercial medical ultrasound with a PC running commercial PIV software is described and preliminary validation measurements in pipe flow using UCV and optical particle image velocimetry (PIV) are reported. In principles of operation, UCV is similar to the technique of PIV, differing only in the image acquisition process. The benefits of UCV are that it does not require optical access to the flow field and can be used for measuring flows of opaque fluids. While the limitations of UVC are the inherently low frame rates (limited by the imaging capabilities of the commercial ultrasound system) and low spatial resolution, which limits the range of velocities and transient flow behavior that can be measured. The support of the NSF (CBET0846359, grant monitor Horst Henning Winter) is gratefully acknowledged.
Prognostic value of three-dimensional ultrasound for fetal hydronephrosis
WANG, JUNMEI; YING, WEIWEN; TANG, DAXING; YANG, LIMING; LIU, DONGSHENG; LIU, YUANHUI; PAN, JIAOE; XIE, XING
2015-01-01
The present study evaluated the prognostic value of three-dimensional ultrasound for fetal hydronephrosis. Pregnant females with fetal hydronephrosis were enrolled and a novel three-dimensional ultrasound indicator, renal parenchymal volume/kidney volume, was introduced to predict the postnatal prognosis of fetal hydronephrosis in comparison with commonly used ultrasound indicators. All ultrasound indicators of fetal hydronephrosis could predict whether postnatal surgery was required for fetal hydronephrosis; however, the predictive performance of renal parenchymal volume/kidney volume measurements as an individual indicator was the highest. In conclusion, ultrasound is important in predicting whether postnatal surgery is required for fetal hydronephrosis, and the three-dimensional ultrasound indicator renal parenchymal volume/kidney volume has a high predictive performance. Furthermore, the majority of cases of fetal hydronephrosis spontaneously regress subsequent to birth, and the regression time is closely associated with ultrasound indicators. PMID:25667626
Skates, Steven J; Greene, Mark H; Buys, Saundra S; Mai, Phuong L; Brown, Powel; Piedmonte, Marion; Rodriguez, Gustavo; Schorge, John O; Sherman, Mark; Daly, Mary B; Rutherford, Thomas; Brewster, Wendy R; O'Malley, David M; Partridge, Edward; Boggess, John; Drescher, Charles W; Isaacs, Claudine; Berchuck, Andrew; Domchek, Susan; Davidson, Susan A; Edwards, Robert; Elg, Steven A; Wakeley, Katie; Phillips, Kelly-Anne; Armstrong, Deborah; Horowitz, Ira; Fabian, Carol J; Walker, Joan; Sluss, Patrick M; Welch, William; Minasian, Lori; Horick, Nora K; Kasten, Carol H; Nayfield, Susan; Alberts, David; Finkelstein, Dianne M; Lu, Karen H
2017-07-15
Purpose: Women at familial/genetic ovarian cancer risk often undergo screening despite unproven efficacy. Research suggests each woman has her own CA125 baseline; significant increases above this level may identify cancers earlier than standard 6- to 12-monthly CA125 > 35 U/mL. Experimental Design: Data from prospective Cancer Genetics Network and Gynecologic Oncology Group trials, which screened 3,692 women (13,080 woman-screening years) with a strong breast/ovarian cancer family history or BRCA1/2 mutations, were combined to assess a novel screening strategy. Specifically, serum CA125 q3 months, evaluated using a risk of ovarian cancer algorithm (ROCA), detected significant increases above each subject's baseline, which triggered transvaginal ultrasound. Specificity and positive predictive value (PPV) were compared with levels derived from general population screening (specificity 90%, PPV 10%), and stage-at-detection was compared with historical high-risk controls. Results: Specificity for ultrasound referral was 92% versus 90% ( P = 0.0001), and PPV was 4.6% versus 10% ( P > 0.10). Eighteen of 19 malignant ovarian neoplasms [prevalent = 4, incident = 6, risk-reducing salpingo-oophorectomy (RRSO) = 9] were detected via screening or RRSO. Among incident cases (which best reflect long-term screening performance), three of six invasive cancers were early-stage (I/II; 50% vs. 10% historical BRCA1 controls; P = 0.016). Six of nine RRSO-related cases were stage I. ROCA flagged three of six (50%) incident cases before CA125 exceeded 35 U/mL. Eight of nine patients with stages 0/I/II ovarian cancer were alive at last follow-up (median 6 years). Conclusions: For screened women at familial/genetic ovarian cancer risk, ROCA q3 months had better early-stage sensitivity at high specificity, and low yet possibly acceptable PPV compared with CA125 > 35 U/mL q6/q12 months, warranting further larger cohort evaluation. Clin Cancer Res; 23(14); 3628-37. ©2017 AACR . ©2017 American Association for Cancer Research.
Froyman, Wouter; Wynants, Laure; Landolfo, Chiara; Bourne, Tom; Valentin, Lil; Testa, Antonia; Sladkevicius, Povilas; Franchi, Dorella; Fischerova, Daniela; Savelli, Luca; Van Calster, Ben; Timmerman, Dirk
2017-06-02
The aim of this study was to assess and compare the performance of different ultrasound-based International Ovarian Tumor Analysis (IOTA) strategies and subjective assessment for the diagnosis of early stage ovarian malignancy. This is a secondary analysis of a prospective multicenter cross-sectional diagnostic accuracy study that included 1653 patients recruited at 18 centers from 2009 to 2012. All patients underwent standardized transvaginal ultrasonography by experienced ultrasound investigators. We assessed test performance of the IOTA Simple Rules (SRs), Simple Rules Risk (SRR), the Assessment of Different NEoplasias in the adneXa (ADNEX) model and subjective assessment to discriminate between stage I-II ovarian cancer and benign disease. Reference standard was histology after surgery. 230 (13.9%) patients proved to have stage I-II primary invasive ovarian malignancy, and 1423 (86.1%) had benign disease. Sensitivity and specificity with respect to malignancy (95% confidence intervals) of the original SRs (classifying all inconclusive cases as malignant) were 94.3% (90.6% to 96.7%) and 73.4% (71.0% to 75.6%). Subjective assessment had a sensitivity and specificity of 90.0% (85.4% to 93.2%) and 86.7% (84.9% to 88.4%), respectively. The areas under the receiver operator characteristic curves of SRR and ADNEX were 0.917 (0.902 to 0.933) and 0.905 (0.920 to 0.934), respectively. At a 1% risk cut-off, sensitivity and specificity for SRR were 100% (98.4% to 100%) and 38.0% (35.5% to 40.6%), and for ADNEX were 100% (98.4% to 100%) and 19.4% (17.4% to 21.5%). At a 30% risk cut-off, sensitivity and specificity for SRR were 88.3% (83.5% to 91.8%) and 81.1% (79% to 83%), and for ADNEX were 84.5% (80.5% to 89.6%) and 84.5% (82.6% to 86.3%). This study shows that all three IOTA strategies have good ability to discriminate between stage I-II ovarian malignancy and benign disease.
USDA-ARS?s Scientific Manuscript database
In three separate studies (156 pigs total), DXA, BIA, and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body l...
Noncontact modal analysis of a pipe organ reed using airborne ultrasound stimulated vibrometry
NASA Astrophysics Data System (ADS)
Huber, Thomas M.; Fatemi, Mostafa; Kinnick, Randall R.; Greenleaf, James F.
2004-05-01
The goal of this experiment was to excite and measure, in a noncontact manner, the vibrational modes of the reed from a reed organ pipe. To perform ultrasound stimulated excitation, two ultrasound beams in air of different frequencies were directed at the reed; the audio-range beat frequency between these ultrasound beams induced vibrations. The resulting vibrational deflection shapes were measured with a scanning vibrometer. The modes of any relatively small object can be studied in air using this technique. For a 36 mm by 7 mm clamped brass reed cantilever, displacements and velocites of 5 μ and 4 mm/s could be imparted at the fundamental frequency of 145 Hz. Using the same ultrasound transducer, excitation across the entire range of audio frequencies was obtained, which was not possible using audio excitation with a speaker. Since the beam was focused on the reed, ultrasound stimulated excitation eliminated background effects observed during mechanical shaker excitation, such as vibrations of clamps and supports. We will discuss the results obtained using single, dual, and confocal ultrasound transducers in AM and unmodulated CW modes, along with results obtained using a mechanical shaker and audio excitation using a speaker.
Ultrasound Assessment of Human Meniscus.
Viren, Tuomas; Honkanen, Juuso T; Danso, Elvis K; Rieppo, Lassi; Korhonen, Rami K; Töyräs, Juha
2017-09-01
The aim of the present study was to evaluate the applicability of ultrasound imaging to quantitative assessment of human meniscus in vitro. Meniscus samples (n = 26) were harvested from 13 knee joints of non-arthritic human cadavers. Subsequently, three locations (anterior, center and posterior) from each meniscus were imaged with two ultrasound transducers (frequencies 9 and 40 MHz), and quantitative ultrasound parameters were determined. Furthermore, partial-least-squares regression analysis was applied for ultrasound signal to determine the relations between ultrasound scattering and meniscus integrity. Significant correlations between measured and predicted meniscus compositions and mechanical properties were obtained (R 2 = 0.38-0.69, p < 0.05). The relationship between conventional ultrasound parameters and integrity of the meniscus was weaker. To conclude, ultrasound imaging exhibited a potential for evaluation of meniscus integrity. Higher ultrasound frequency combined with multivariate analysis of ultrasound backscattering was found to be the most sensitive for evaluation of meniscus integrity. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Oh-Oka, Hitoshi; Nose, Ryuichiro
2005-09-01
Using a portable three dimensional ultrasound scanning device (The Bladder Scan BVI6100, Diagnostic Ultrasound Corporation), we examined measured values of bladder volume, especially focusing on volume lower than 100 ml. A total of 100 patients (male: 66, female: 34) were enrolled in the study. We made a comparison study between the measured value (the average of three measurements of bladder urine volume after a trial in male and female modes) using BVI6100, and the actual measured value of the sample obtained by urethral catheterization in each patient. We examined the factors which could increase the error rate. We also introduced the effective techniques to reduce measurement errors. The actual measured values in all patients correlated well with the average value of three measurements after a trial in a male mode of the BVI6100. The correlation coefficient was 0.887, the error rate was--4.6 +/- 24.5%, and the average coefficient of variation was 15.2. It was observed that the measurement result using the BVI6100 is influenced by patient side factors (extracted edges between bladder wall and urine, thickened bladder wall, irregular bladder wall, flattened rate of bladder, mistaking prostate for bladder in male, mistaking bladder for uterus in a female mode, etc.) or examiner side factors (angle between BVI and abdominal wall, compatibility between abdominal wall and ultrasound probe, controlling deflection while using probe, etc). When appropriate patients are chosen and proper measurement is performed, BVI6100 provides significantly higher accuracy in determining bladder volume, compared with existing abdominal ultrasound methods. BVI6100 is a convenient and extremely effective device also for the measurement of bladder urine over 100 ml.
Krukenberg carcinoma metastasized from stomach resembling mucinous cystadenocarcinoma of the ovary.
Doğanay, Melike; Topçu, Hasan Onur; Kokanalı, Mahmut Kuntay; Güzel, Ali I Rfan; Oskovi, Aslı; Akbay, Serap; Cavkaytar, Sabri
2017-09-01
The ovaries are common site of metastasis in a variety of primary neoplasms. Multiple tumors such as breast, lung, and pancreas have been reported to metastasize to the ovary, however; the colon and stomach are the most common primary cancer sites that of ovarian metastasis. An ovarian mass mostly originates from its self-tissue, but sometimes it can be a metastasis of a gastrointestinal system tumor. Such cases are often misdiagnosed as primary ovarian cancers. A 42-year-old woman was admitted to our hospital with pelvic pain. She had a history of her complaints for two months. Bilateral large ovarian mass was detected in transvaginal ultrasound. Laparotomy was performed, the pathologist suggested inspection of the stomach after the frozen section analysis; therefore, an irregular mass on the stomach was detected. The general surgeon was attended to the operation, and an inoperative stomach tumor was reported by the general surgeon. After that due to the partial obstruction of jejunum, a gastrojejunostomy was performed. It is in fact difficult to distinguish between metastatic mucinous carcinomas and primary mucinous carcinomas of the ovary, due to the similar appearance of as cystic tumors on gross examination. The clinicians should be aware of the likely concomitant gastrointestinal system tumor when a large and bilaterally mass was detected on physical examination. This case also reminds that a systemic examination is necessary even if the large ovarian tumors suspicious of primary malignancy were noticed.
Krukenberg carcinoma metastasized from stomach resembling mucinous cystadenocarcinoma of the ovary.
Doğanay, Melike; Topçu, Hasan Onur; Kokanali, Mahmut Kuntay; Güzel, Ali Irfan; Oskovi, Asli; Akbay, Serap; Cavkaytar, Sabri
2015-01-01
The ovaries are common site of metastasis in a variety of primary neoplasms. Multiple tumors such as breast, lung, and pancreas have been reported to metastasize to the ovary, however; the colon and stomach are the most common primary cancer sites that of ovarian metastasis. An ovarian mass mostly originates from its self-tissue, but sometimes it can be a metastasis of a gastrointestinal system tumor. Such cases are often misdiagnosed as primary ovarian cancers. A 42-year-old woman was admitted to our hospital with pelvic pain. She had a history of her complaints for two months. Bilateral large ovarian mass was detected in transvaginal ultrasound. Laparotomy was performed, the pathologist suggested inspection of the stomach after the frozen section analysis; therefore, an irregular mass on the stomach was detected. The general surgeon was attended to the operation, and an inoperative stomach tumor was reported by the general surgeon. After that due to the partial obstruction of jejunum, a gastrojejunostomy was performed. It is in fact difficult to distinguish between metastatic mucinous carcinomas and primary mucinous carcinomas of the ovary, due to the similar appearance of as cystic tumors on gross examination. The clinicians should be aware of the likely concomitant gastrointestinal system tumor when a large and bilaterally mass was detected on physical examination. This case also reminds that a systemic examination is necessary even if the large ovarian tumors suspicious of primary malignancy were noticed.
Oocyte recovery by ovum pick up and embryo production in river buffaloes (Bubalus bubalis).
Manjunatha, B M; Ravindra, J P; Gupta, P S P; Devaraj, M; Nandi, S
2008-08-01
Ovum pick up (OPU) was conducted twice a week for 12 weeks in six cycling, non-descriptive (local breed), Indian buffaloes to study the efficiency of OPU on recovery of oocytes for embryo production. OPU was performed using an ultrasound equipment with a 5-MHz transvaginal transducer, a single-lumen, 18-gauge, 55-cm-long needle and a constant vacuum pressure of 110 mmHg. The number and size of follicles were determined before puncture. The recovered oocytes were graded, washed, matured for 24 h and then fertilized with frozen-thawed semen, followed by embryo culture on the oviductal monolayer. The mean number of follicles observed per animal per session did not differ between animals or between puncture sessions. A mean number of 3.62 +/- 0.32 mm follicles were observed, 2.90 +/- 0.15 mm follicles were punctured and 1.21 +/- 0.07 oocytes were recovered per animal per session, with an average recovery rate of 42%. Of the total oocytes recovered, 64% were suitable for in vitro embryo production (grade A + B) whereas 36% were classified to be of grades C + D. A mean number of 0.25 +/- 0.2 transferable embryos was produced in vitro per buffalo per session with a transferable embryo production rate of 32%. In conclusion, this study demonstrated that twice-a-week OPU could be applied repeatedly, without any adverse effects on the follicular growth and oocyte recovery and that recovered oocytes could be used for in vitro embryo production in buffaloes.
Retroperitoneal ectopic pregnancy: a case report and review of the literature.
Yang, Man; Cidan, Lamu; Zhang, Dan
2017-10-16
Retroperitoneal ectopic pregnancy (REP) is an extremely rare type of ectopic pregnancy, with a total of less than 20 cases reported in the English literature. However, failure to recognize REP may result in severe consequences. We report a case of 32-year-old woman with REP. She had amenorrhea, left lower abdominal pain, but no vaginal bleeding. Her urine human chorionic gonadotropin (HCG) test was positive and blood HCG level was 1880 m-international units per milliliter (mIU/mL). Transvaginal ultrasound sonography showed a left adnexal mass. Laparoscopy found an enlarged uterus, normal right uterine tube and ovary, and normal left uterine tube. The left ovary was partly covered by a blood clot, but appeared normal after removing the clot. There was a 10-mm circular peritoneal defect located lateral to the left sacrocervical ligament, anterior to the left ovarian fossa, and next to the lower edge of the left broad ligament. The patient was diagnosed of having REP with the gestational tissues covered by the peritoneum. The REP was removed by laparoscopic surgery. Bleeding was stopped by bipolar coagulation and absorbable hemostatic cellulose. The patient recovered smoothly and was discharged on the next day after surgery. Her blood HCG returned to normal range 29 days after surgery. REP is very rare, but in any suspected case of ectopic pregnancy, caution must be paid to find signs of REP when the common sites of ectopic pregnancy do not have any positive findings.
Bennich, G; Rudnicki, M; Wilken-Jensen, C; Lousen, T; Lassen, P D; Wøjdemann, K
2016-04-01
To investigate short- and long-term effects on residual myometrial thickness (RMT) of adding a second layer to a single unlocked closure of a Cesarean uterine incision. This was a randomized double-blind controlled trial. Healthy nulliparous women scheduled for first-time elective Cesarean delivery were operated on using a modified version of the Misgav Ladach surgical technique. The women were examined by transabdominal ultrasound before discharge from the maternity ward and by transvaginal saline contrast sonohysterography at a minimum of 5 months postpartum. Seventy-six nulliparae met the criteria and agreed to participate in the study. Thirty-five women were assigned to the single-layer technique and 38 to the double-layer unlocked closure technique. Groups were comparable regarding gestational age at delivery, duration of surgery and perioperative blood loss. There was no difference in RMT between the two groups, both at time of discharge (mean ± SD, 20.2 ± 8.0 mm vs 21.0 ± 9.7 mm) and after 5 months postpartum (mean, 5.7 ± 2.9 mm vs 5.7 ± 2.2 mm). RMT was approximately half that of the normal myometrium at both examinations. The results of this study suggest that double-layer closure of a Cesarean uterine incision does not increase RMT compared with single-layer closure when an unlocked technique is used. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Welt, C K; Gudmundsson, J A; Arason, G; Adams, J; Palsdottir, H; Gudlaugsdottir, G; Ingadottir, G; Crowley, W F
2006-12-01
The Rotterdam criteria for polycystic ovary syndrome (PCOS) defines discrete subgroups whose phenotypes are not yet clear. The phenotypic characteristics of women in the PCOS subgroups defined by the Rotterdam criteria were compared. The study was observational. Subjects were studied in an outpatient setting in Boston and Reykjavik. Four subgroups of subjects with PCOS defined by 1) irregular menses (IM), hyperandrogenism (HA), and polycystic ovary morphology (PCOM, n = 298); 2) IM/HA (n = 7); 3) HA/PCOM (n = 77); and 4) IM/PCOM (n = 36) and a group of controls (n = 64), aged 18-45 yr, were examined. Subjects underwent a physical exam; fasting blood samples for androgens, gonadotropins, and metabolic parameters; and a transvaginal ultrasound. The phenotype was compared between groups. Ninety-seven percent of women with IM/HA had PCOM. Therefore, the groups with and without PCOM were combined. The Ferriman-Gallwey score and androgen levels were highest in the hyperandrogenic groups (IM/HA and HA/PCOM), whereas ovarian volume was higher in all PCOS subgroups compared with controls, as expected based on the definitions of the PCOS subgroups. Body mass index and insulin levels were highest in the IM/HA subgroup. Subjects with PCOS defined by IM/HA are the most severely affected women on the basis of androgen levels, ovarian volumes, and insulin levels. Their higher body mass index partially accounts for the increased insulin levels, suggesting that weight gain exacerbates the symptoms of PCOS.
Doroudi, Maryam; Kramer, Barnett S; Pinsky, Paul F
2017-12-01
Objective To provide evidence about the performance characteristics and consequences of bimanual ovarian palpation. Setting and methods The Prostate, Lung, Colorectal and Ovarian cancer screening trial randomized 154,900 individuals to either an intervention or control arm. Enrolled eligible participants were aged 55-74, had no history of trial cancers, and no current treatment for cancer. Intervention arm women received CA-125 tests and transvaginal ultrasound. Bimanual ovarian palpation was offered annually during the first four years of the trial. Bimanual ovarian palpation-specific sensitivity and specificity were calculated, as were rates of diagnostic procedures and resulting complications following positive bimanual ovarian palpation screens. Results A total of 20,872 women received at least one bimanual ovarian palpation, with 50,498 total bimanual ovarian palpation examinations performed. The sensitivity and specificity of bimanual ovarian palpation were 5.1% (2/39) and 99.0% (49,957/50,459), respectively; no cases were detected by bimanual ovarian palpation alone. Rates for most follow-up procedures for abnormal results in women without ovarian cancer were higher among the group with another screening test positive, except for pelvic exam, where rates were similar. No complications were reported in the bimanual ovarian palpation-only positive group. Conclusion Low sensitivity of bimanual ovarian palpation alone and in combination with other tests argue against using bimanual ovarian palpation as a screening test for ovarian cancer in asymptomatic women.
Influence of lactoferrin in preventing preterm delivery: a pilot study.
Giunta, Giuliana; Giuffrida, Lorena; Mangano, Katia; Fagone, Paolo; Cianci, Antonio
2012-01-01
Lactoferrin (Lf) is an approximately 80-kDa iron-binding glycoprotein, belonging to the transferrin family, with well-known bacteriostatic and bactericidal properties. It is produced and stored in specific (secondary) neutrophil granules and released during neutrophil activation and degranulation. Nowadays, Lf has a well-known therapeutic indication for combating iron deficiency anemia (IDA) in pregnant women. Studies suggest that Lf plays an important role against cervicovaginal infections by decreasing cytokines levels, such as interleukin (IL)-6, in cervicovaginal fluid. The aim of this preliminary trial was to evaluate the effectiveness of Lf in preventing preterm delivery caused by cervical infections and ripening. From November 2009 to August 2010, 21 pregnant women (26-32 weeks pregnant), aged between 22 and 36 years, suffering from IDA, at risk of preterm delivery, were prospectively enrolled in the study. One group (N=14) received 100 mg of recombinant human lactoferrin (bLf) [corrected] (lattoferrina; AG-pharma) twice a day before meals, for one month. The other group (N=7) received 520 mg of ferrous sulfate (Ferro-Grad; Abbott Laboratories, USA) once a day. The patients underwent transvaginal ultrasound to evaluate cervical length and funneling, and vaginal swabs were used to detect infections and cervicovaginal fluid sample collection to determine IL-6 levels. The results showed a correlation between the oral administration of 200 mg of bLf [corrected] with both the normalization of vaginal flora (vaginal infection disappearance) and the decrease in IL-6 cervicovaginal fluid levels in women at risk of preterm delivery.
Zupi, Errico; Centini, Gabriele; Lazzeri, Lucia; Finco, Andrea; Exacoustos, Caterina; Afors, Karolina; Zullo, Fulvio; Petraglia, Felice
2015-01-01
To compare long-term efficacy of laparoscopic supracervical hysterectomy (LSH) and hysteroscopic endometrial ablation (HEA) in treating persistent abnormal uterine bleeding. Canadian Task Force II-2. University hospital. One hundred fifty-three women treated for abnormal uterine bleeding by LSH or HEA. Long-term follow-up assessment of reintervention rate and quality of life (QoL) using the Quality Metric's Health Survey Short Form 12. This study is the long-term follow-up of a randomized control trial conducted in 2003 comparing LSH and HEA in terms of reoperation rate and QoL. Starting from November 2010 all patients included in the first trial were invited to participate in this study and clinically evaluated through vaginal examination and transvaginal ultrasound. After a mean follow-up of 14.4 years, 29% of patients (20/71) treated with HEA underwent further surgery, whereas no patients after LSH had symptom recurrence. The reintervention rate was significantly higher in the HEA group (p < .0001), with a relative risk of 1.39 (95% confidence interval, 1.20-1.61). The assessment of QoL demonstrated a higher score, in both physical and mental components, in the LSH group (p < .0001). The lower reintervention rate and the better physical and mental health scores make LSH a more suitable procedure to treat recurrent abnormal uterine bleeding when compared with HEA. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Tetar, Shyama; Bohoudi, Omar; Nieboer, Theodoor; Lagerwaard, Frank
2018-01-01
In this case presentation, we describe the challenges of performing magnetic resonance-guided radiation therapy (MRgRT) with plan adaptation in a patient with advanced endometriosis, in whom several prior therapeutic attempts were unsuccessful and extensive pelvic irradiation was regarded as being too toxic. Treatment was delivered in two sessions, first for the seemingly only active right ovary, and at a later stage for the left ovary. Some logistical problems were encountered during the preparation of the first treatment, which were subsequently optimized for the second treatment by using transvaginal ultrasound to determine the optimum time point for simulation and delivery. Using breath-hold gated delivery and plan adaptation, radiation dose to the bowel could be minimized, resulting in good tolerance of treatment. Because of the need to simulate and deliver in a brief optimal time span for visibility of the follicles in the ovaries, a single fraction dose of 8 Gy was used in our patient. Hormonal outcome after her second treatment is still pending. In conclusion, MRgRT with plan adaptation is feasible for the occasional patient with refractory endometriosis. Simulation and delivery needs to be synchronized with the menstrual cycle, ensuring that the Graafian follicles allow the ovaries to be visible on magnetic resonance imaging (MRI). Because the ovaries are only visible on T2-weighted MRI for a very brief period of time, we suggest that it is preferable to use single fraction radiotherapy with a brief interval between simulation imaging and delivery. PMID:29750135
Parisi, Francesca; Rousian, Melek; Steegers-Theunissen, Régine P M; Koning, Anton H J; Willemsen, Sten P; de Vries, Jeanne H M; Cetin, Irene; Steegers, Eric A P
2018-04-20
Maternal dietary patterns were associated with embryonic growth and congenital anomalies. We aim to evaluate associations between early first trimester maternal dietary patterns and embryonic morphological development among pregnancies with non-malformed outcome. A total of 228 strictly dated, singleton pregnancies without congenital malformations were enrolled in a periconceptional hospital-based cohort. Principal component analysis was performed to extract early first trimester maternal dietary patterns from food frequency questionnaires. Serial transvaginal three-dimensional ultrasound (3D US) scans were performed between 6 +0 and 10 +2 gestational weeks and internal and external morphological criteria were used to define Carnegie stages in a virtual reality system. Associations between dietary patterns and Carnegie stages were investigated using linear mixed models. A total of 726 3D US scans were included (median: three scans per pregnancy). The 'high fish and olive oil and low meat' dietary pattern was associated with accelerated embryonic development in the study population (β = 0.12 (95%CI: 0.00; 0.24), p < 0.05). Weak adherence to this dietary pattern delayed embryonic development by 2.1 days (95%CI: 1.6; 2.6) compared to strong adherence. The 'high vegetables, fruit and grain' dietary pattern accelerated embryonic development in the strictly dated spontaneous pregnancy subgroup without adjustment for energy intake. Early first trimester maternal dietary patterns impacts human embryonic morphological development among pregnancies without congenital malformations. The clinical meaning of delayed embryonic development needs further investigation.
F18-FDG coincidence-PET in patients with suspected gynecological malignancy.
Zor, E; Stokkel, M P; Ozalp, S; Vardareli, E; Yalçin, O Tarik; Ak, I
2006-07-01
To assess the role of F18-FDG imaging with a dual-head coincidence mode gamma camera (Co-PET) in identifying malignant tumors in patients with a suspicious adnexal mass depicted by conventional imaging methods. F18-FDG Co-PET was performed preoperatively in 18 women (mean age 56.38 years) with suspected malignant gynecologic tumors according to clinical and abdomino-pelvic/transvaginal ultrasound or computed tomography findings. Exploratory laparotomy was performed in all patients within the 10 days post-F18-FDG Co-PET study, and the definitive diagnosis of the adnexal masses was established by histopathological examination. Histopathological examinations of the surgically excised adnexal masses revealed eight malignant, one borderline, and nine benign neoplastic tumors. Four benign tumors had no F18-FDG uptake, while the remaining five tumors, all leiomyomas, showed mild FDG accumulation. Eight malignant tumors showed intense F18-FDG uptake. Sensitivity, specificity, PPV, and NPV of F18-FDG co-PET in differentiating benign from malign adnexal masses were 88%, 44%, 61%, and 80%, respectively. Tumor to background ratios (T/B) in benign lesions (2.04 +/- 0.27) were significantly lower than in malignant lesions (7.4 +/- 0.99). F18-FDG Co-PET is of clinical value when assessing suspicious malignant adnexal masses. False-negative F18-FDG results might arise from borderline disease. Moderate F18-FDG uptake in leiomyomas can result false-positive, but T/B ratios may be helpful in such cases.
Feasibility of 3.0T pelvic MR imaging in the evaluation of endometriosis.
Manganaro, L; Fierro, F; Tomei, A; Irimia, D; Lodise, P; Sergi, M E; Vinci, V; Sollazzo, P; Porpora, M G; Delfini, R; Vittori, G; Marini, M
2012-06-01
Endometriosis represents an important clinical problem in women of reproductive age with high impact on quality of life, work productivity and health care management. The aim of this study is to define the role of 3T magnetom system MRI in the evaluation of endometriosis. Forty-six women, with transvaginal (TV) ultrasound examination positive for endometriosis, with pelvic pain, or infertile underwent an MR 3.0T examination with the following protocol: T2 weighted FRFSE HR sequences, T2 weighted FRFSE HR CUBE 3D sequences, T1 w FSE sequences, LAVA-flex sequences. Pelvic anatomy, macroscopic endometriosis implants, deep endometriosis implants, fallopian tube involvement, adhesions presence, fluid effusion in Douglas pouch, uterus and kidney pathologies or anomalies associated and sacral nervous routes were considered by two radiologists in consensus. Laparoscopy was considered the gold standard. MRI imaging diagnosed deep endometriosis in 22/46 patients, endometriomas not associated to deep implants in 9/46 patients, 15/46 patients resulted negative for endometriosis, 11 of 22 patients with deep endometriosis reported ovarian endometriosis cyst. We obtained high percentages of sensibility (96.97%), specificity (100.00%), VPP (100.00%), VPN (92.86%). Pelvic MRI performed with 3T system guarantees high spatial and contrast resolution, providing accurate information about endometriosis implants, with a good pre-surgery mapping of the lesions involving both bowels and bladder surface and recto-uterine ligaments. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R
2016-04-18
To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.
NASA Astrophysics Data System (ADS)
Povey, Malcolm J. W.
2016-12-01
Nucleation in food colloids has been studied in detail using ultrasound spectroscopy. Our data show that classical nucleation theory (CNT) remains a sound basis from which to understand nucleation in food colloids and analogous model systems using n-alkanes. Various interpretations and modifications of CNT are discussed with regard to their relevance to food colloids. Much of the evidence presented is based on the ultrasound velocity spectrometry measurements which has many advantages for the study of nucleating systems compared to light scattering and NMR due to its sensitivity at low solid contents and its ability to measure true solid contents in the nucleation and early crystal growth stages. Ultrasound attenuation spectroscopy also responds to critical fluctuations in the induction region. We show, however, that a periodic pressure fluctuation such as a quasi-continuous (as opposed to a pulse comprising only a few pressure cycles) ultrasound field can alter the nucleation process, even at very low acoustic intensity. Thus care must be taken when using ultrasound techniques that the measurements do not alter the studied processes. Quasi-continuous ultrasound fields may enhance or suppress nucleation and the criteria to determine such effects are derived. The conclusions of this paper are relevant to colloidal systems in foods, pharmaceuticals, agro-chemicals, cosmetics, and personal products.
Ultrasound Image Despeckling Using Stochastic Distance-Based BM3D.
Santos, Cid A N; Martins, Diego L N; Mascarenhas, Nelson D A
2017-06-01
Ultrasound image despeckling is an important research field, since it can improve the interpretability of one of the main categories of medical imaging. Many techniques have been tried over the years for ultrasound despeckling, and more recently, a great deal of attention has been focused on patch-based methods, such as non-local means and block-matching collaborative filtering (BM3D). A common idea in these recent methods is the measure of distance between patches, originally proposed as the Euclidean distance, for filtering additive white Gaussian noise. In this paper, we derive new stochastic distances for the Fisher-Tippett distribution, based on well-known statistical divergences, and use them as patch distance measures in a modified version of the BM3D algorithm for despeckling log-compressed ultrasound images. State-of-the-art results in filtering simulated, synthetic, and real ultrasound images confirm the potential of the proposed approach.
Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui
2013-03-01
To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.
Zaidman, Craig M; Malkus, Elizabeth C; Connolly, Anne M
2015-09-01
Quantitative muscle ultrasound (QUS) in boys with Duchenne muscular dystrophy (DMD) shows increased echointensity as muscle is replaced with fat and fibrosis. Studies of quantitative ultrasound in infants/young boys with DMD over time have not been reported. We used calibrated muscle backscatter (cMB), a reproducible measure of ultrasound echointensity, to quantify muscle pathology in 5 young boys with DMD (ages 0.5-2.8 years) over 17-29 months. We compared the results with repeated assessments of function (n = 4) and with muscle ultrasound images from a cross-section of 6 male controls (0.6-3.1 years). cMB in boys with DMD increased (worsened) over time (P < 0.001), whereas function improved. After age 2 years, cMB in most (4 of 5) boys with DMD was higher than in any control. QUS measures disease progression in young boys with DMD despite functional improvements. QUS could be employed as an outcome measure for serial assessment of young boys with DMD. © 2015 Wiley Periodicals, Inc.
Kliper, Yael; Ben-Ami, Moshe; Perlitz, Yuri
2014-01-01
The aim of this study was to assess the effect of mild pressure applied on the abdominal wall by the ultrasound transducer on fetal cephalic indices. We examined by ultrasound 60 fetuses of healthy women, at 20-24 weeks of pregnancy, during routine prenatal evaluation. For every fetus biparietal diameter and head circumference were measured, with and without applying mild pressure by the ultrasound transducer. The weight and gestational age (GA) were calculated. The pressure applied by the transducer had a significant effect on the cephalic indices and on the weight and GA evaluations (p < 0.001). Fetal positioning significantly affected the impact that applied pressure had on head circumference and on the weight evaluation derived from it (p < 0.05). Applied pressure by an abdominal ultrasound probe affects cephalic indices and the derived weight and GA estimations. This may lead to incorrect diagnoses or hide pathological findings. The effect of applied pressure depends on fetal positioning. The examiner must be aware of this effect when evaluating the results of the measurements.
Belohlavek, Marek; Katayama, Minako; Zarbatany, David; Fortuin, F David; Fatemi, Mostafa; Nenadic, Ivan Z; McMahon, Eileen M
2014-07-01
Catheters are increasingly used therapeutically and investigatively. With complex usage comes a need for more accurate intracardiac localization than traditional guidance can provide. An injection catheter navigated by ultrasound was designed and then tested in an open-chest model of acute ischemia in eight pigs. The catheter is made "acoustically active" by a piezo-electric crystal near its tip, electronically controlled, vibrating in the audio frequency range and uniquely identifiable using pulsed-wave Doppler. Another "target" crystal was sutured to the epicardium within the ischemic region. Sonomicrometry was used to measure distances between the two crystals and then compared with measurements from 2-D echocardiographic images. Complete data were obtained from seven pigs, and the correlation between sonomicrometry and ultrasound measurements was excellent (p < 0.0001, ρ = 0.9820), as was the intraclass correlation coefficient (0.96) between two observers. These initial experimental results suggest high accuracy of ultrasound navigation of the acoustically active catheter prototype located inside the beating left ventricle. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Módis, László; Szalai, Eszter; Németh, Gábor; Berta, András
2010-01-01
The study was conducted to assess the central corneal thickness (CCT) of the healthy cornea with a recently developed noncontact specular microscope (EM-3000; Tomey) and compare the results with those measured with a contact specular microscope and an ultrasound pachymeter. Agreement between measurements taken by 2 investigators was also studied. The right eyes of 41 healthy individuals who had negative history of contact lens wear, ophthalmic disease, or ocular surgery were examined. The CCT was determined sequentially with a noncontact specular microscope, a contact specular microscope (EM-1000; Tomey), and an ultrasound pachymeter (AL-2000; Tomey). Each evaluation with the specular microscopes was performed by 2 independent operators. A significant difference was detected in pachymetry measurements among the 3 instruments (p=0.01; analysis of variance). The mean CCT values were lower measured with the ultrasound pachymeter (537+/-30 microm) than the contact endothelial microscope (543+/-37 microm, p=0.17, Student t-test) and the noncontact microscope (549+/-33 microm, p<0.0001) (operator 1). There was no statistically significant difference in CCT measurements between the 2 endothelial microscopes (p=0.19). We found significant correlations (p<0.0001) in thickness measurements between each pair of instruments (r=0.91, noncontact microscopy and ultrasound pachymetry; r=0.74, noncontact and contact microscopy; r=0.72, contact microscopy and ultrasound pachymetry; Spearman rank correlation). The strong correlations among the 3 pachymetry devices suggest that the tested instruments provide reliable measurements; however, they cannot be used interchangeably.
Comparison of extraction methods for quantifying vitamin E from animal tissues.
Xu, Zhimin
2008-12-01
Four extraction methods: (1) solvent (SOL), (2) ultrasound assisted solvent (UA), (3) saponification and solvent (SP), and (4) saponification and ultrasound assisted solvent (SP-UA), were used in sample preparation for quantifying vitamin E (tocopherols) in chicken liver and plasma samples. The extraction yields of SOL, UA, SP, and SP-UA methods obtained by adding delta-tocopherol as internal reference were 95%, 104%, 65%, and 62% for liver and 98%, 103%, 97%, and 94% for plasma, respectively. The methods with saponification significantly affected the stabilities of tocopherols in liver samples. The measured values of alpha- and gamma-tocopherols using the solvent only extraction (SOL) method were much lower than that using any of the other extraction methods. This indicated that less of the tocopherols in those samples were in a form that could be extracted directly by solvent. The measured value of alpha-tocopherol in the liver sample using the ultrasound assisted solvent (UA) method was 1.5-2.5 times of that obtained from the saponification and solvent (SP) method. The differences in measured values of tocopherols in the plasma samples by using the two methods were not significant. However, the measured value of the saponification and ultrasound assisted solvent (SP-UA) method was lower than either the saponification and solvent (SP) or the ultrasound assisted solvent (UA) method. Also, the reproducibility of the ultrasound assisted solvent (UA) method was greater than any of the saponification methods. Compared with the traditional saponification method, the ultrasound assisted solvent method could effectively extract tocopherols from sample matrix without any chemical degradation reactions, especially for complex animal tissue such as liver.
Paquette, Philippe; El Khamlichi, Youssef; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H
2017-08-01
Quantitative ultrasound imaging is gaining popularity in research and clinical settings to measure the neuromechanical properties of the peripheral nerves such as their capability to glide in response to body segment movement. Increasing evidence suggests that impaired median nerve longitudinal excursion is associated with carpal tunnel syndrome. To date, psychometric properties of longitudinal nerve excursion measurements using quantitative ultrasound imaging have not been extensively investigated. This study investigates the convergent validity of the longitudinal nerve excursion by comparing measures obtained using quantitative ultrasound imaging with those determined with a motion analysis system. A 38-cm long rigid nerve-phantom model was used to assess the longitudinal excursion in a laboratory environment. The nerve-phantom model, immersed in a 20-cm deep container filled with a gelatin-based solution, was moved 20 times using a linear forward and backward motion. Three light-emitting diodes were used to record nerve-phantom excursion with a motion analysis system, while a 5-cm linear transducer allowed simultaneous recording via ultrasound imaging. Both measurement techniques yielded excellent association ( r = 0.99) and agreement (mean absolute difference between methods = 0.85 mm; mean relative difference between methods = 7.48 %). Small discrepancies were largely found when larger excursions (i.e. > 10 mm) were performed, revealing slight underestimation of the excursion by the ultrasound imaging analysis software. Quantitative ultrasound imaging is an accurate method to assess the longitudinal excursion of an in vitro nerve-phantom model and appears relevant for future research protocols investigating the neuromechanical properties of the peripheral nerves.
Synergistic effect of ultrasound and PEI on DNA transfection in vitro
Deshpande, Mangesh C.; Prausnitz, Mark R.
2007-01-01
Ultrasound and poly(ethylenimine) (PEI) have each separately been shown to increase DNA transfection efficiency. This study tested the hypothesis that the combination of ultrasound and PEI can have a synergistic effect to increase DNA transfection. This in vitro study assessed transfection efficiency of two different DNA plasmids encoding green fluorescent protein and firefly luciferase in two different cells types, a primary culture of human aortic smooth muscle cells and an immortal line of human prostrate cancer cells. We found that ultrasound sonication increased transfection up to 18-fold, DNA complexation with PEI increased transfection up to 90-fold, and the combination of ultrasound and PEI synergistically increased transfection up to 200-fold, which resulted in reporter gene expression by 34% of cells. Kinetic measurements found that the effects of ultrasound alone acted quickly, whereas increased transfection by PEI either alone or in combination with ultrasound strongly benefited from a 4-h incubation with the DNA plasmid after sonication. Although serum reduced absolute expression levels, it did not affect the relative increase in transfection when ultrasound was added to PEI enhancement. Flow cytometry measurements showed that sonication increased intracellular uptake of labelled DNA complexed to PEI by 55% relative to PEI complexation alone. Electrophoresis assay showed no damage to DNA or PEI-DNA complexes after sonication. Overall, these results suggest that the combination of ultrasound and PEI can have a synergistic effect to increase DNA transfection. PMID:17258835
Noh, Dong Koog; Koh, Jae-Hyun; You, Joshua Sung-H
2016-01-01
The purpose of this study was to determine intertester and intratester reliability of ultrasound measurements of bilateral diaphragm excursions in the thoracic and thoracolumbar spinal curves of 31 females with adolescent idiopathic scoliosis (AIS) (mean age = 14.1 ± 1.8 years). Subjects were tested during tidal breathing using real-time ultrasound imaging with a 3.5 MHz curvilinear transducer. There were no significant differences in intratester and intertester reliability values in bilateral diaphragmatic excursions measured at the thoracolumbar spinal curve, whereas significant differences were observed in measurements taken at the thoracic spinal curve (p < 0.05). Overall, the intertester and intratester reliabilities of the thoracic and thoracolumbar curves in AIS ranged from 0.764 to 0.998. These findings suggest that ultrasound imaging is highly reliable between and within testers and is useful to precisely discriminate pathological diaphragm movement in idiopathic thoracic scoliosis and idiopathic thoracolumbar scoliosis.
Characterization of Pressure Fields of Focused Transducers at TÜBİTAK UME
NASA Astrophysics Data System (ADS)
Karaböce, B.; Şahin, A.; İnce, A. T.; Skarlatos, Y.
Field radiated by HIFU (High Intensity Focused Ultrasound) has been investigated by measuring its pressure field and mapping in 2-D and 3-D. A new ultrasound pressure measurement system has been designed and constructed at TÜBİTAK UME (The Scientific and Technological Research Council of Turkey, the National Metrology Institute). System consists of a water tank, positioning system, measurement devices and a controlling program. The hydrophone was attached to a 3-axis, computer-controlled positioning system for alignment with the ultrasound source. The signal was captured and analyzed by the commercially available LabVIEW 8.1 software. The measurements of the ultrasound field were carried out with a needle hydrophone. For each waveform, p, p+ and p-pressures have been calculated. Wave behaviors produced by the KZK model and from experiments look like similar in general. In p, p+, p- the focal point, zero point after the primary peak (focus) and extremum points in the near field well match.
A concept for non-invasive temperature measurement during injection moulding processes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopmann, Christian; Spekowius, Marcel, E-mail: spekowius@ikv.rwth-aachen.de; Wipperfürth, Jens
2016-03-09
Current models of the injection moulding process insufficiently consider the thermal interactions between melt, solidified material and the mould. A detailed description requires a deep understanding of the underlying processes and a precise observation of the temperature. Because todays measurement concepts do not allow a non-invasive analysis it is necessary to find new measurement techniques for temperature measurements during the manufacturing process. In this work we present the idea of a set up for a tomographic ultrasound measurement of the temperature field inside a plastics melt. The goal is to identify a concept that can be installed on a specializedmore » mould for the injection moulding process. The challenges are discussed and the design of a prototype is shown. Special attention is given to the spatial arrangement of the sensors. Besides the design of a measurement set up a reconstruction strategy for the ultrasound signals is required. We present an approach in which an image processing algorithm can be used to calculate a temperature distribution from the ultrasound scans. We discuss a reconstruction strategy in which the ultrasound signals are converted into a spartial temperature distribution by using pvT curves that are obtained by dilatometer measurements.« less
Office-based ultrasound screening for abdominal aortic aneurysm
Blois, Beau
2012-01-01
Abstract Objective To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). Design A prospective observational study. Consecutive patients were approached by nonphysician staff. Setting Rural family physician offices in Grand Forks and Revelstoke, BC. Participants The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. Main outcome measures A focused “quick screen,” which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (ie, a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Results Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Conclusion Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point-of-care ultrasound technology. The screening test can be completed within the time constraints of a busy family practice office visit. The benefit of screening for AAA in rural patients might be great if local diagnostic ultrasound service and emergent transport to a vascular surgeon are not available. PMID:22518906
Notten, Kim J B; Vergeldt, Tineke F M; van Kuijk, Sander M J; Weemhoff, Mirjam; Roovers, Jan-Paul W R
The aim of this study was to assess the diagnostic accuracy and clinical implications of translabial 3-dimensional (3D) ultrasound for the assessment of levator ani defects and biometry in women with pelvic organ prolapse (POP). We performed a systematic literature search through computerized databases including MEDLINE (via PubMed), EMBASE (via OvidSP), and the Cochrane Library using both medical subject headings and text terms from January 1, 2003, to December 25, 2015.We included articles that reported on POP status and diagnostic accuracy measurements with translabial 3D ultrasound or transperineal ultrasound for the detection of levator ani defects or for measuring pelvic floor biometry, that is, levator ani hiatus, or reported on the clinical relevance of using translabial 3D ultrasound for levator ani defects or measuring pelvic floor biometry in women with POP. Thirty-one articles were selected in accordance with parts of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines that can be applied to studies of diagnostic accuracy. Twenty-two articles (71%) are coauthored by 1 expert in this field. Detecting levator ani defects with translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to good agreement, whereas measuring hiatal biometry on translabial 3D ultrasound compared with magnetic resonance imaging showed a moderate to very good agreement.The interobserver agreement for diagnosing levator ani defects and measuring the levator hiatal area showed a moderate to very good agreement. Furthermore, levator ani defects increase the risk of cystocele and uterine prolapse, and levator ani defects are associated with recurrent POP.Finally, a larger hiatus was associated with POP and recurrent POP. Translabial 3D ultrasound is reproducible for diagnosing levator ani defects and ballooning hiatus. Both levator ani defects and a larger hiatal area are, in a selected population of patients with pelvic floor dysfunction, associated with POP and recurrent POP. More research is needed concerning external validation because most data in this article are coauthored by 1 expert in this field.
Chun, Guan-Chun; Chiang, Hsing-Jung; Lin, Kuan-Hung; Li, Chien-Ming; Chen, Pei-Jarn; Chen, Tainsong
2015-01-01
The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastography, the eSNR and depth of ultrasound penetration must be increased using chirp-coded excitation. Moreover, the low axial resolution of ultrasound images generated by a chirp-coded pulse must be increased using an appropriate compression filter. The main aim of this study is to develop an ultrasound elasticity imaging system with chirp-coded excitation using a Tukey window for assessing the biomechanical properties of soft tissues. In this study, we propose an ultrasound elasticity imaging system equipped with a 7.5-MHz single-element transducer and polymethylpentene compression plate to measure strains in soft tissues. Soft tissue strains were analyzed using cross correlation (CC) and absolution difference (AD) algorithms. The optimal parameters of CC and AD algorithms used for the ultrasound elasticity imaging system with chirp-coded excitation were determined by measuring the elastographic signal-to-noise ratio (SNRe) of a homogeneous phantom. Moreover, chirp-coded excitation and short pulse excitation were used to measure the elasticity properties of the phantom. The elastographic qualities of the tissue-mimicking phantom were assessed in terms of Young’s modulus and elastographic contrast-to-noise ratio (CNRe). The results show that the developed ultrasound elasticity imaging system with chirp-coded excitation modulated by a Tukey window can acquire accurate, high-quality elastography images. PMID:28793718
NASA Astrophysics Data System (ADS)
Haller, J.; Wilkens, V.
2017-03-01
The objective of this work was to create highly stable therapeutic ultrasound fields with well-known exposimetry and dosimetry parameters that are reproducible and hence predictable with well-known uncertainties. Such well- known and reproducible fields would allow validation and secondary calibrations of different measuring capabilities, which is already a widely accepted strategy for diagnostic fields. For this purpose, a reference setup was established that comprises two therapeutic ultrasound sources (one High-Intensity Therapeutic Ultrasound (HITU) source and one physiotherapy-like source), standard rf electronics for signal creation, and computer-controlled feedback to stabilize the input voltage. The short- and longtime stability of the acoustic output were evaluated - for the former, measurements over typical laboratory measurement time periods (i.e. some seconds or minutes) of the input voltage stability with and without feedback control were performed. For the latter, measurements of typical acoustical exposimetry parameters were performed bimonthly over one year. The measurement results show that the short- and the longtime stability of the reference setup are very good and that it is especially significantly improved in comparison to a setup without any feedback control.
Ultrasound transmission measurements for tensile strength evaluation of tablets.
Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko
2011-05-16
Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.
Effect of ultrasound on electrochemical chloride extraction from mortar
NASA Astrophysics Data System (ADS)
Chen, Yiqun; Yao, Wu; Zuo, Junqing
2018-03-01
In this paper, the effect of auxiliary ultrasound on electrochemical chloride extraction (ECE) was studied. The chloride removal efficiency was investigated by examining the chloride content with ultrasound-assisted ECE and changing the introducing time of ultrasound. The experimental results showed that removal of chloride ions was noted to be more effective in ECE treatment assisted with ultrasound treatment (UT). In addition, the lower w/c ratio led to more distinct effect of ultrasonic cavitation on chloride removal. Electrochemical behaviors measured with different treatment revealed that UT treatment was effective on moderating the corrosion condition. Microstructural analyses revealed a significant alteration in composition and morphology of cementitious phases with UT treatment. Pull-out tests indicated that ultrasound had a certain negative impact on the bond strength. Although the effect of introducing ultrasound in the first 2 weeks or the last 2 weeks on the extraction efficiency was not obvious, intermittent ultrasound could not only ensure the chloride extraction efficiency, but also reduce the adverse effect of ultrasound on the bond strength.
USDA-ARS?s Scientific Manuscript database
The experiment was designed to validate the use of ultrasound to evaluate body composition in mature beef cows. Both precision and accuracy of measurement were assessed. Cull cows (n = 87) selected for highly variable fatness were used. Two experienced ultrasound technicians scanned and assigned ...
Prospective Controlled Study of Buttock Fat Transfer Using Ultrasound and Photographic Measurements
2016-01-01
Background: Buttock fat transfer is now the preferred method for gluteal augmentation. However, its efficacy has not been well-documented using measurements. Methods: Twenty-five consecutive patients underwent buttock fat transfer performed by the author. Twenty-one patients returned for measurements ≥3 months after surgery (inclusion rate, 84%). A separate group of 25 patients undergoing cosmetic surgery without buttock fat transfer served as controls. All patients underwent superwet liposuction using total intravenous anesthesia and no prone positioning. A closed filtration system was used to collect the fat. Subcutaneous fat thickness was assessed using ultrasound imaging. Measurements were made on standardized photographs. The data were controlled for change in body mass index. Clinical data were also evaluated. Results: The mean fat volume injected per buttock was 287 mL (range, 70–550 mL). Ultrasound measurements detected a significant increase in the subcutaneous fat thickness (P ≤ 0.001), with mean increments of 0.66 cm for the right buttock and 0.86 cm for the left buttock and no significant change for control patients. The mean calculated fat retention, based on the measured surface area injected, was 66%. Photographic measurements of buttock projection revealed a significant increase in treated patients (P < 0.01) and no significant change in control patients. There were no clinical complications at either recipient or donor sites and no evidence of oily cysts on ultrasound examinations. Conclusions: Photographic and ultrasound measurements, and clinical findings, confirm that buttock fat transfer effectively and safely increases buttock projection. PMID:27579222
Noncontact modal analysis of a pipe organ reed using airborne ultrasound stimulated vibrometry.
Huber, Thomas M; Fatemi, Mostafa; Kinnick, Randy; Greenleaf, James
2006-04-01
The goal of this study was to excite and measure, in a noncontact manner, the vibrational modes of the reed from a reed organ pipe. To perform ultrasound stimulated excitation, the audio-range difference frequency between a pair of ultrasound beams produced a radiation force that induced vibrations. The resulting vibrational deflection shapes were measured with a scanning laser vibrometer. The resonances of any relatively small object can be studied in air using this technique. For a 36 mm x 6 mm brass reed, displacements and velocities in excess of 5 microm and 4 mm/s could be imparted at the fundamental frequency of 145 Hz. Using the same ultrasound transducer, excitation across the entire range of audio frequencies was obtained. Since the beam was focused on the reed, ultrasound stimulated excitation eliminated background effects observed during mechanical shaker excitation, such as vibrations of clamps and supports. The results obtained using single, dual and confocal ultrasound transducers in AM and two-beam modes, along with results obtained using a mechanical shaker and audio excitation using a speaker are discussed.