Sample records for traumatic hip dislocation

  1. Pseudo-Acetabulum due to Heterotopic Ossification in a Child with Post Traumatic Neglected Posterior Hip Dislocation.

    PubMed

    Pathak, Aditya C; Patil, Atul K; Sheth, Binoti; Bansal, Rohan

    2012-01-01

    Traumatic neglected dislocations of hip in children are rare entity. Neglected traumatic dislocations of hip in children along with heterotopic ossification are still rare. Post traumatic neglected hip dislocations are to be diagnosed as early as possible and have to be treated with precision and aggression as the outcome of treatment for the same is not predictable. 5 year female with post-traumatic neglected hip dislocation with heterotopic ossification forming a pseudoacetabulum postero-superiorly in which femur head was lodged. The girl was operated by open reduction using Moore's Posterior approach and showed good results. Here is a mention of a rare case with a good 18 months follow up with no complication. Post-traumatic neglected posterior hip dislocation mostly requires open reduction and relocation of femoral head in original acetabulum with concentric reduction. Heterotopic ossification is a rare but known complication of traumatic dislocation of hip in children. Good results can be achieved in such cases and regular follow-up of patient is required post-operatively.

  2. Traumatic hip dislocation at a regional trauma centre in Nigeria.

    PubMed

    Onyemaechi, N O C; Eyichukwu, G O

    2011-01-01

    Traumatic dislocation or fracture-dislocation of the hip is an orthopaedic emergency that is steadily increasing in incidence due to high-speed motor vehicular accidents. These injuries need to be recognized early and promptly treated to prevent morbidity and long-term complications. Some of the fundamental issues in the management of traumatic dislocations of the hip are the critical interval between injury and reduction, the type of reduction most suitable for various types of injury and the duration of immobilization that give the best results. This study was carried out at the National Orthopaedic Hospital Enugu, a regional trauma and orthopaedic centre in South-East Nigeria. The purpose of the study is to describe the pattern of presentation and to identify the factors that determine the long-term outcome in the treatment of traumatic dislocations and fracture-dislocations of the hip at Enugu, Nigeria. The case notes of all the patients that presented with traumatic dislocations and fracture-dislocations of the hip between January 2003 and December 2007 were reviewed. The information extracted and analyzed included the patients' demographics, etiology of injury, time interval before reduction, associated injuries, treatment offered, complications and follow-up. Thompson-Epstein classification was used to grade the posterior hip dislocations. The outcome of treatment was evaluated using the clinical and radiological criteria proposed by Epstein (1974). Three patients with incomplete data and two patients with central fracture dislocation were excluded from this study. Forty-eight patients with 50 hip dislocations were analyzed. The age range was 12 years to 67 years with a mean age of 34.8 years. Thirty-nine patients (81.3%) were males and 9 (18.7%) were females. Road-traffic accident was the leading cause of traumatic hip dislocation in this series, 44 cases (91.6%). Posterior dislocation occurred in 48 hips (96%) while anterior dislocation occurred in 2 hips (4%). Forty-seven hips (94%) were treated by primary closed reduction, two hips (4%) were treated with open reduction and one patient (2%) had Girdlestone excision arthroplasty. Thirty-six hips (73.5%) were reduced with 12 hours of the injury. Concomitant injuries were found in 37 patients (77%). The follow up period ranged from 10 months to 36 months with a mean follow up period of 15 months. Post-traumatic osteoarthritis occurred in 2 hips (4%) avascular necrosis of the femoral head was seen in 2 hips (4%). Five patients had sciatic nerve paresis while there was recurrence in one hip. No mortality was recorded. Traumatic dislocations and fracture-dislocations of the hip are severe injuries caused mostly by high-speed motor-vehicular accidents. Young adult males are most commonly affected, and there is a high rate of concomitant injuries. Excellent results can be achieved by early and stable closed reduction of these injuries with immobilization of the affected hips.

  3. A Rare Case of Neglected Traumatic Anterior Dislocation of Hip in a Child.

    PubMed

    Mootha, Aditya Krishna; Mogali, Kasi Viswanadam

    2016-01-01

    Post traumatic hip dislocations are very rare in children. Neglected anterior hip dislocations in children are not described in literature so far. Here, we present a case of 6 weeks old anterior hip dislocation successfully managed by open reduction. A 9-year-old male child presented with neglected anterior hip dislocation on left side. Open reduction carried out through direct anterior approach to hip. Congruent reduction is achieved. At final follow up of 1 year, the child had unrestricted activities of daily living and no radiological signs of osteonecrosis or any joint space reduction. There is paucity of literature over neglected post traumatic anterior hip dislocations in children. The treatment options vary from closed reduction after heavy traction to sub trochanteric osteotomy. However, we feel that open reduction through direct anterior approach is the preferred mode of management whenever considered possible.

  4. [Acute traumatic and especially neglected traumatic hip dislocations are very rare in children].

    PubMed

    Fernandez, F F; Wirth, T; Eberhardt, O

    2012-09-01

    We report about the first hip arthroscopies of extracapsular neglected hip dislocations with concomitant injuries in two children (2 and 4 years old). The major problem of traumatic hip dislocation is avascular necrosis. Further problems are possible concomitant injuries. It is important not to cause further damage by therapeutic procedures. In a 4-year-old child the hip could be reduced under visualization and in a 2-year-old child with epiphyseal fracture the extent of the operation could be reduced. In both children large avulsion injuries of the ligamentum capitis femoris could be resected via hip arthroscopy. Hip arthroscopy can reduce surgical morbidity considerably and can possibly contribute to prevention of the feared avascular necrosis of the femoral head.

  5. Arthroscopic Anterior and Posterior Labral Repair After Traumatic Hip Dislocation: Case Report and Review of the Literature

    PubMed Central

    Shindle, Michael K.; Kelly, Bryan T.

    2010-01-01

    With the improvements in flexible instrumentation, hip arthroscopy is being increasingly used to treat a variety of hip pathology, including labral tears. However, up to this point, there has not been a case report of an anterior and a posterior labral tear successfully repaired arthroscopically. We present a case report of a 27-year-old male firefighter who presented to our institution with an anterior and posterior labral tear, as well as a cam lesion and loose body, following a traumatic hip dislocation. The purpose of this case report is to illustrate that both anterior and posterior labral tears can be repaired using hip arthroscopy. Anterior and posterior labral tears can be caused by a traumatic hip dislocation, and both can be successfully repaired using arthroscopic techniques. PMID:21886540

  6. [Relevance of MRI After Closed Reduction of Traumatic Hip Dislocation in Children].

    PubMed

    Strüwind, Christoph Mauritz; von Rüden, Christian; Thannheimer, Andreas; Bühren, Volker; Schneidmueller, Dorien

    2018-05-14

    Traumatic hip dislocation in children and adolescents is a rare entity that typically results from high-energy trauma. After closed joint reduction, further treatment depends on the specific pattern of the lesion as identified using cross sectional imaging. The aim of this retrospective analysis was to evaluate relevant side effects after traumatic hip dislocation in children and adolescents in order to examine the need for focused diagnostics. This retrospective analysis covered 8 adolescents under 18 years suffering isolated traumatic hip joint dislocation between 2001 and 2017. In all patients, closed joint reduction was performed immediately after admission to the emergency room. In order to evaluate the complete extent of the injury, 5 patients received an MRI and 3 patients a CT scan following closed joint reduction. Two female and 6 male patients with a median age of 11 (range 5 - 16) years were included. In 2 cases, a free joint body was detected in the posterior joint gap in the posttraumatic CT scan after closed joint reduction. Interposition of the labrum into the joint gap was detected intraoperatively in both cases. In one patient who received posttraumatic MRI, labral interposition into the joint gap was observed after closed reduction. These findings were confirmed intraoperatively. In 4 other patients, no posttraumatic labral lesion was detected in the MRI after closed reduction. The reported side effects included ruptured anterior inferior iliac spine and ruptured femoral head ligament. MRI is gaining increasing importance following traumatic hip dislocation in children and adolescents. A missing chondral or osteochondral fragment in the CT scan does not exclude a labral lesion or interposition. Therefore, MRI following closed reduction is mandatory in any case. Georg Thieme Verlag KG Stuttgart · New York.

  7. Posterior hip dislocation in a non-professional football player: a case report and review of the literature.

    PubMed

    Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros

    2018-06-02

    The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.

  8. Neglected Posterior Dislocation of Hip in Children - A Case Report.

    PubMed

    Pal, Chandra Prakash; Kumar, Deepak; Sadana, Ashwani; Dinkar, Karuna Shankar

    2014-01-01

    Traumatic dislocation of the hip in children is a rare injury. We report the outcome of 2 patients of neglected hip dislocation which were treated by open reduction and internal fixation by k-wires. We treat 2 children both girls (one was of 4 years and other was 7 years of age). In both cases dislocation was unilateral and was not associated with any facture. Both cases were of posterior dislocation. in both cases open reduction and internal fixation was done by k wires. Hip spica was applied post operatively in both cases. The k wire was removed at 3 to 4 weeks. Patients were allowed to bear weight from gradual to full weight bearing after 6 weeks. We conclude that open reduction is a satisfactory treatment for neglected hip dislocation. It prevents not only deformity but also maintains limb length.

  9. Systematic Review and Meta-Analysis of Avascular Necrosis and Posttraumatic Arthritis After Traumatic Hip Dislocation.

    PubMed

    Kellam, Patrick; Ostrum, Robert F

    2016-01-01

    To determine the incidence rate and associative factors for the development of avascular necrosis (AVN) and posttraumatic arthritis (PTA) after traumatic hip dislocation and time to reduction. A comprehensive search of databases including PubMed, Cochrane Database, and Embase through April 2014 for English articles reporting complications of AVN and PTA after hip dislocation was performed. Inclusion criteria were English-only studies, a patient population of adults, study outcomes of AVN and/or PTA reported, and articles reported at least type I dislocations. Two authors independently extracted data from the selected studies and the data collected were compared to verify agreement. Random-effects models were used for meta-analysis. The overall event rate of AVN and PTA was calculated and stratified based on Thompson-Epstein of the hip dislocation. Odds ratios were calculated for those articles that reported rates of AVN based on time to reduction. For anterior dislocations, the event rate for AVN ranged from 0.087 to 0.333, whereas the event rate for PTA ranged from 0.125 to 0.700. Analysis of posterior dislocations revealed that the event rate for AVN ranged from 0.106 to 0.430; additionally, the event rate for PTA ranged from 0.194 to 0.586. For posterior hip dislocations and type I and II anterior dislocations, the severity of the injury correlates with an increase in the development of AVN and PTA. The odds ratio of AVN for those hip dislocations reduced after 12 hours versus those reduced before 12 hours was 5.627. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  10. Traumatic fracture-dislocation of the hip following rugby tackle: a case report.

    PubMed

    Venkatachalam, Santosh; Heidari, Nima; Greer, Tony

    2009-12-15

    Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.

  11. Traumatic fracture-dislocation of the hip following rugby tackle: a case report

    PubMed Central

    2009-01-01

    Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months. PMID:20003496

  12. Ipsilateral obturator type of hip dislocation with fracture shaft femur in a child: a case report and literature review.

    PubMed

    Arjun, R H H; Kumar, Vishal; Saibaba, Balaji; John, Rakesh; Guled, Uday; Aggarwal, Sameer

    2016-09-01

    The incidence of traumatic hip dislocations in children is rising in this fast developing world along with increasing numbers of high-velocity road traffic accidents. Anterior dislocation of the hip has a lower incidence compared with posterior dislocation of the hip. We encountered a rare case of the obturator type of anteriorly dislocated hip associated with ipsilateral fracture of the shaft femur in an 11-year-old child. This is a highly unusual injury combination and the mechanism of injury is obscure. Only two similar cases have been reported in the English literature to date. Closed reduction of the hip using a hitherto undescribed technique and an intramedullary interlocking nail was performed in this case. At 6 months of follow-up, the fracture shaft femur has united and the child is bearing full weight on the limb.

  13. Hip dislocations and concurrent injuries in motor vehicle collisions.

    PubMed

    Cooper, Joseph; Tilan, Justin; Rounds, Alexis D; Rosario, Santano; Inaba, Kenji; Marecek, Geoffrey S

    2018-04-27

    Motor Vehicle Collisions (MVC) can cause high energy hip dislocations associated with serious injury profiles impacting triage. Changes in safety and regulation of restraint devices have likely lowered serious injuries from what was previously reported in the 1990s. This study aims to describe modern-day injury profile of patients with traumatic hip dislocations, with special attention to aortic injury. Retrospective review of a prospectively maintained trauma database at an urban level 1 trauma center was conducted. Patients with hip dislocation following MVC between January 2005 and December 2015 were grouped based on seatbelt use and airbag deployment. Patients with unknown restraint use were excluded. Multiple logistic regression was used to identify risk of injury profile between groups. Of 204 patients with hip dislocation after MVC, nearly 57% were unrestrained. Seatbelt alone was used in 36 (17.7%), airbag deployed in 14 (6.9%), and 38 (18.6%) with both. Gender and number of injuries were similar between groups. The most common concomitant injury was acetabular fracture (53.92%) and the abdominopelvic region was the most injured. Use of a seatbelt with airbag deployment was protective of concomitant pelvic ring injury (OR = 0.22). Airbag deployment was significantly protective of lumbar fracture (OR = 0.15) while increasing the likelihood of radial and ulnar fracture or dislocation (OR = 3.27), acetabular fracture (OR = 5.19), and abdominopelvic injury (OR = 5.07). The no restraint group had one patient (0.80%) with an intimal tear of the thoracic aorta identified on CT chest that was successfully medically managed. Hip dislocations are high energy injuries with severe associated injuries despite upgrades in restraint devices. These patients require careful examination and heightened awareness when evaluating for concomitant injuries. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Closed bone graft epiphysiodesis for avascular necrosis of the capital femoral epiphysis.

    PubMed

    Thompson, George H; Lea, Ethan S; Chin, Kenneth; Liu, Raymond W; Son-Hing, Jochen P; Gilmore, Allison

    2013-07-01

    Avascular necrosis (AVN) of the capital femoral epiphysis (CFE) after an unstable slipped capital femoral epiphysis (SCFE), femoral neck fracture or traumatic hip dislocation can result in severe morbidity. Treatment options for immature patients with AVN are limited, including a closed bone graft epiphysiodesis (CBGE). However, it is unclear whether this procedure prevents AVN progression. We investigated whether early MRI screening and CBGE prevented the development of advanced AVN changes in the CFE and the rates of complications with this approach. We prospectively followed all 13 patients (seven boys, six girls) with unstable SCFEs (six patients), femoral neck fractures (five patients), and traumatic hip dislocations (two patients) and evidence of early AVN treated between 1984 and 2012. Mean age at initial injury was 12 years (range, 10-16 years). Nine of the 13 patients had followup of at least 2 years or until conversion to THA (mean, 4.5 years; range, 0.8-8.5 years), including two with unstable SCFEs, the five with femoral neck fractures, and the two with traumatic hip dislocations. All patients had technetium scans and/or MRI within 1 to 2 months of their initial injury (before CBGE) and all had evidence of early (Ficat 0) AVN. Patients were followed clinically and radiographically for AVN progression. Six of the nine hips did not develop typical clinical or radiographic evidence of AVN. These six patients have been followed 6.3 years (range, 4.3-9.1 years) from initial injury and 5.9 years (range, 3.8-8.5 years) from CBGE. The remaining three patients were diagnosed with AVN at periods ranging from 3 to 6 months after CBGE. Early recognition and treatment of AVN with a CBGE may alter the natural history of this complication. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.

  15. Hip arthroscopy: prevalence of intra-articular pathologic findings after traumatic injury of the hip.

    PubMed

    Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H

    2014-03-01

    The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when compared with hip arthroscopy after a traumatic injury of the hip. Level IV, diagnostic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. A case report of the management and the outcome of a complete epiphyseal separation and dislocation with left anterior column fracture of the acetabulum.

    PubMed

    Palencia, Jesús; Alfayez, Saud; Serro, Firas; Alqahtani, Jamal; Alharbi, Hani; Alhinai, Hamed

    2016-01-01

    Femoral head and neck fractures in children are uncommon, accounting for fewer than 1% of all pediatric fractures and fewer than 8% of all hip fractures. Furthermore, traumatic transphyseal hip fracture is rare to present in daily practice especially when associated with an acetabular fracture. A twelve years old boy, not known to have any chronic illnesses, presented to the emergency department as a case of polytrauma after a road traffic accident. Signs of left hip dislocation were discovered upon physical examination. X-rays and CT scans, revealed a complete transphyseal posterior dislocation and a left anterior column fracture of the acetabulum with a minimal displacement. Within five hours, the patient underwent open reduction and internal fixation by two cannulated screws. The acetabular fracture was managed conservatively. After six months, there were clear signs of osteonecrosis of the femoral head. A high-energy trauma in children and adolescents can lead to simultaneous epiphyseal and acetabular fractures which are associated with a poor prognosis. The age seems to play a role as patients older than ten years have a higher risk of developing AVN after sustaining a hip dislocation regardless of the time of intervention. Epiphyseal fracture with dislocation of the femoral head is rare among children and adolescents, especially when associated with an acetabular fracture. AVN in such cases can develop, and it represents a challenge to orthopedic surgeons due to the poor prognosis and the future functional limitations of the joint. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    PubMed

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p < 0.001, respectively). However, there were no significant differences in hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.

  18. Jacob's limp.

    PubMed

    Hoenig, L J

    1997-02-01

    This study describes in modern medical terms a traumatic hip injury suffered by the Biblical patriarch Jacob approximately 3,500 years ago. The case history is based on the original Hebrew text found in the Bible book of Genesis (Chapter 32:25-33) as interpreted by traditional Jewish commentaries on the Bible. Jacob sustained a hip injury in hand-to-hand combat with an adversary or through an intense physiological reaction to a prophetic vision of such a battle. He appears to have sustained neurological injury to his sciatic nerve as well as musculoskeletal damage to his hip. These injuries caused a temporary limping gait. Jacob probably sustained a neurapraxia of the sciatic nerve. The differential diagnosis of his musculoskeletal hip injury includes hip dislocation, fracture, soft tissue trauma, and articular pathology.

  19. Ipsilateral hip and knee dislocation: Case report and review of literature

    PubMed Central

    Sharma, Gaurav; Chahar, Deepak; Sreenivasan, Ravi; Verma, Nikhil; Pankaj, Amite

    2016-01-01

    Hip and knee dislocations are not uncommon but simultaneous ipsilateral dislocation of the hip and knee joint is rare; consequently, there is an inadequate amount of literature on the subject. We identified only 11 such cases reported in English literature. In the present report, we describe the case of a 23-year-old male patient who presented with ipsilateral hip and knee dislocation on the right side after being involved in a road traffic accident. The hip dislocation was associated with a posterior wall acetabular fracture. The hip as well as the knee joints was reduced in the emergency bay. The patient underwent an urgent fixation of the posterior wall acetabular fracture with delayed ligament reconstruction for the knee dislocation. At one-year follow-up, he had no pain in the hip or knee. There was grade 1 posterior sag but no symptoms of knee instability. Radiographs revealed no evidence of avascular necrosis or arthritis of the femoral head. The normal treatment protocol for individual injury is affected by the simultaneous occurrence of hip and knee dislocation. PMID:27182149

  20. Investigation into three dimensional hip anatomy in anterior dislocation after THA. Influence of the position of the hip rotation centre.

    PubMed

    Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick

    2012-07-01

    The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement

    PubMed Central

    Zhang, Dagang; Chen, Long; Wang, Guanglin

    2016-01-01

    Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133

  2. Steel syndrome: dislocated hips and radial heads, carpal coalition, scoliosis, short stature, and characteristic facial features.

    PubMed

    Flynn, John M; Ramirez, Norman; Betz, Randal; Mulcahey, Mary Jane; Pino, Franz; Herrera-Soto, Jose A; Carlo, Simon; Cornier, Alberto S

    2010-01-01

    A syndrome of children with short stature, bilateral hip dislocations, radial head dislocations, carpal coalitions, scoliosis, and cavus feet in Puerto Rican children, was reported by Steel et al in 1993. The syndrome was described as a unique entity with dismal results after conventional treatment of dislocated hips. The purpose of this study is to reevaluate this patient population with a longer follow-up and delineate the clinical and radiologic features, treatment outcomes, and the genetic characteristics. This is a retrospective cohort study of 32 patients in whom we evaluated the clinical, imaging data, and genetic characteristics. We compare the findings and quality of life in patients with this syndrome who have had attempts at reduction of the hips versus those who did not have the treatment. Congenital hip dislocations were present in 100% of the patients. There was no attempt at reduction in 39% (25/64) of the hips. In the remaining 61% (39/64), the hips were treated with a variety of modalities fraught with complications. Of those treated, 85% (33/39) remain dislocated, the rest of the hips continue subluxated with acetabular dysplasia and pain. The group of hips that were not treated reported fewer complaints and limitation in daily activities compared with the hips that had attempts at reduction. Steel syndrome is a distinct clinical entity characterized by short stature, bilateral hip and radial head dislocation, carpal coalition, scoliosis, cavus feet, and characteristic facial features with dismal results for attempts at reduction of the hips. Prognostic Study Level II.

  3. Influence of age on the outcome of single stage reconstructive surgery for congenital dislocation of the hip joint.

    PubMed

    Bhatti, Anisuddin; Jamali, A R; Mehboob, Ghulam

    2009-01-01

    This study was conducted to assess the effect of age on the ultimate outcome measures following single stage surgical procedure of soft tissue release, relocation, capsulorrhaphy, femoral shortening with varus/derotation osteotomy and pelvic osteotomy. A case series. The study with two groups of pretest-posttest design was conducted at Department of Orthopaedic Surgery, Jinnah Postgraduate Medical Centre (JPMC), Karachi, from 1993 to January 2008. Patients included were having neglected, congenital dislocation of the hip joint, aged over 3 years. Patients with failed previous surgery, paralytic, teratological, traumatic or septic dislocations and patients with less than 5 years follow-up were excluded from the study. The patients were divided into two groups, 3-7 years (37 hip joints) and over 7 years (13 hip joints). The single stage surgical procedure of open relocation, femoral shortening/derotation/ varus osteotomy and pelvic osteotomy was the dependent variable; whereas, the final clinico-radiological results based upon Tonnis grading, Severin's clinical/radiological grading, Klisic's overall rating and acetabular index were the independent variables of the study. Pre- and postoperative data was assessed for overall improvement and the difference in outcome measures between the two age groups. Significant overall improvement on all parameters was achieved after surgery. When results were compared between two age groups, there was no significant difference in the final outcome as per Tonnis grading and Severin's clinical typing as modified by Gibson (97.3% versus 84.4% normal hip joints or Tonnis grade 1 and 78.37% versus 53.85% Severin's type 1) but the results based upon Severin's radiological grading (62.16% versus 15.38%) and Klisic's overall rating (62.16% versus 15.38%) were significantly better in 3-7 years as compared to those over 7 years. There was no significant difference between the two age groups when compared for improvement in acetabular index. On further analysis, a progressive deterioration of results with increasing age was observed, yet the results in those aged over 7 years were reasonably justified surgical correction of congenital dislocation of the hip joint. Majority of the complications were seen in children operated at the age of 4-5 years. There were 7 cases (14%) of redislocation/subluxation and 6 were in 3-7 years age group. There were 4 cases (8%) of the avascular necrosis of the femoral head. Three patients had residual coxa vara and 2 had significant limb shortening. Limb lengthening was done in these 2 cases. The final results displayed progressive deterioration of clinical, radiological and functional outcome measures with aging after single stage reconstructive surgery for the congenital dislocation of hip joint. However, despite this, the results in children over 7 years were also good/excellent in most of the cases justifying surgery.

  4. A Rare Case of Morel-Lavallee Syndrome Complicating an Anterior Dislocation of Hip Joint.

    PubMed

    Nekkanti, Supreeth; Vijay, C; Theja, Sujana; Shankar, R Ravi; Verma, Anubhav

    2016-01-01

    Hip dislocations are serious injuries as hip joint is an extremely stable joint. It requires a significant amount of force to produce such an injury. Anterior dislocations are uncommon. Potential complications of anterior hip dislocations are a neurovascular injury to femoral vessels or acetabular fractures. We report a rare late complication of Morel-Lavallee syndrome occurring 3 weeks after an anterior dislocation of the hip in a 43-year-old male. The patient presented to us with history. Morel-Lavallee syndrome is a rare complication. However if diagnosed early can be successfully treated with minimal burden to the patient. The authors recommend surgeons to have a high index of suspicion for this syndrome and a stringent follow-up examination of the patient.

  5. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial.

    PubMed

    Howie, Donald W; Holubowycz, Oksana T; Middleton, Robert

    2012-06-20

    The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.

  6. Paleoepidemiolgical patterns of trauma in a prehistoric population from central California.

    PubMed

    Jurmain, R

    2001-05-01

    Skeletal trauma was investigated in a large collection of human remains from central California (N = 162 aged and sexed adults). Lesions investigated included cranial and long bone fractures, projectile wounds, and dislocation. Long bone fractures were found in 10.5% of individuals; overall, incidence by element was 2.3%. In addition, cranial injuries were found in 4.4% of complete adult crania. Projectile wounds were seen unambiguously in four individuals (with embedded obsidian fragments) and strongly suggested in two other individuals with partially healed lesions. Finally, one case of traumatic hip dislocation was also observed. In both incidence and patterning of injuries, this population is similar to other archeological groups from California. This evidence further supports earlier reports indicating that interpersonal aggression was quite common in prehistoric California.

  7. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?

    PubMed

    Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi

    2016-05-01

    Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  8. Reducing the rate of early primary hip dislocation by combining a change in surgical technique and an increase in femoral head diameter to 36 mm.

    PubMed

    Ho, Ki Wai Kevin; Whitwell, George S; Young, Steve K

    2012-07-01

    We report how changes to our total hip arthroplasty (THA) surgical practise lead to a decrease in early hip dislocation rates. Group B consisted of 421 consecutive primary THA operations performed via a posterior approach. The operative technique included a meticulous repair of the posterior capsule, alignment of the acetabular cup with the transverse acetabular ligament (TAL) and a 36-mm-diameter femoral head. We compared the dislocation rates and cost implications of this technique to a historical control Group A consisting of 389 patients. The control group had their THA performed with no repair of the capsule, no identification of the TAL and all received a 28-mm-diameter head. Our primary outcome is the rate of early hip dislocation and we hypothesised that we can reduce the rate of early hip dislocation with this new regime. In Group B there were no early dislocations (within 6 months) and two (0.5 %) dislocations within 18 months; minimum follow-up time was 18 months with a range of (18-96 months). This compared to a 1.8 % early dislocation rate and a 2.6 % rate at 18 months in Group A; minimum follow-up time was 60 months with a range of (60-112 months). These results were statistically significant (p = 0.006). We suggest that when primary hip arthroplasty is performed through a posterior approach, a low early dislocation rate can be achieved using the described methods.

  9. Surgical Dislocation of the Hip for the Treatment of Pre-Arthritic Hip Disease.

    PubMed

    Beaulé, Paul E; Singh, Amardeep; Poitras, Stéphane; Parker, Gillian

    2015-09-01

    The purpose of this study was to report the clinical results of surgical dislocation of the hip in the treatment of pre-arthritic hip disease. Between 2005 and 2010, eighty-two patients (89 hips) underwent a surgical dislocation of the hip at a mean age of 30.5 years (range 14.8-51.7); 10 females and 72 males. At a mean follow-up of 7.1 years (range 5-9.6) clinical function improved significantly. 6 patients were converted to total hip arthroplasty and 3 patients underwent an arthroscopy and an additional three patients had >1mm of joint space narrowing at latest follow-up giving us a 9-year cumulative Kaplan-Meier survivorship of 86.4% (CI, 79% to 94%). Thirty-four patients underwent internal fixation removal at a mean of 12.0 months (range 0.3-40.8 months). Although effective in the treatment of early hip disease, the surgical dislocation approach carries a high re-operation rate for removal of internal fixation; consequently, less invasive approaches should be considered for less complex deformities. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Undisplaced Intraoperative Fracture Presenting as Early Dislocation with Tapered Wedge Stems in Total Hip Arthroplasty - Case Series and Review of Literature

    PubMed Central

    Reddy, A V Gurava; Eachempati, Krishna Kiran; Mugalur, Aakash; Suchinder, A; Rao, V B N Prasad; Kamurukuru, Nalanda

    2017-01-01

    Introduction: Periprosthetic fractures and dislocation in the early post-operative period can be disastrous both for the surgeon and the patient. However, undisplaced periprosthetic fractures presenting with dislocation is uncommon. We describe successful management of two cases (one bilateral dislocation and one unilateral dislocation) of undisplaced iatrogenic fractures in total hip arthroplasty (THA) presenting as early dislocation. Case Report: Case 1 was a 45-year-old female with osteoarthritis of hip secondary to developmental dysplasia of the hip with bilateral early nontraumatic dislocation with bilateral identical periprosthetic fracture. It was managed by revision to long stem and encirclage wiring. Case 2 presented with early dislocation in the 2nd week post THA. We found an intertrochanteric fracture intra-operatively with unstable implant. Acetabular component and femoral component revision were done with reconstruction of the greater trochanter. Discussion: These fractures could be occult iatrogenic fractures characteristic of taper wedge stems which presented as early nontraumatic dislocation in the post-operative period. The prosthesis subsidence, loss of muscle tension and change of version might be the factors leading to dislocation. Conclusion: Unrecognized incomplete intraoperative fracture can occur with tapered wedge uncemented stems which can present as a dislocation in the immediate post-operative period. This will require early revision of the femoral component. PMID:29051875

  11. Dual Mobility Cemented Cups Have Low Dislocation Rates in THA Revisions

    PubMed Central

    Langlais, Frantz L.; Gaucher, François; Musset, Thierry; Chaix, Olivier

    2008-01-01

    THA revisions using standard cups are at risk of dislocation (5.1% to 14.4% incidence), especially in patients over 70 years of age. Constrained tripolar cups have reduced this risk (6% incidence) but are associated with substantial loosening rates (9%). The nonconstrained dual mobility cup was designed to improve prosthetic stability (polyethylene head ≥ 40 mm diameter) without increasing loosening rates by reducing wear and limiting impingement (rotation range of 108°). We implanted 88 cemented dual mobility cups for THA revisions in 82 patients at high risk of dislocation. Average patient age was 72 years (range, 65–86 years). Eighty-five of the 88 hips were reviewed at 2 to 5 years followup. One patient (1.1%) had a traumatic dislocation at 2 years postoperatively. Two patients (2.3%) had asymptomatic early loosening and three patients (3.5%) had localized radiographic lucencies. These results confirm those with press-fit dual mobility cups suggesting a low dislocation rate at 5 years and a cup survival of 94.6%. At middle term followup, cemented dual mobility cup achieved better results than constrained cups in cases at risk of dislocation and recurrent loosening. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196422

  12. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    PubMed

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  13. Surgical hip dislocation for treatment of cam femoroacetabular impingement.

    PubMed

    Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, K N; KoKo, Aung; Zaw, Than; Siddhartha, A

    2015-01-01

    Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°-108°) to 46.35° (range 39°-58°). Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.

  14. Intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty - A case report.

    PubMed

    Miyake, Takahito; Kanda, Akio; Morohashi, Itaru; Obayashi, Osamu; Mogami, Atsuhiko; Kaneko, Kazuo

    2017-06-01

    Bipolar hip arthroplasty is a good option for treating femoral neck fractures, although some contraindications have been indicated. We report a case of intraoperative dislocation of the trial bipolar cup into the pelvis during bipolar hip arthroplasty. A 74-year-old woman underwent bipolar hip arthroplasty for a femoral neck fracture (AO31-B2). She was placed in a lateral decubitus position, and a direct lateral approach was used. During intraoperative trial reduction, the trial bipolar cup became disengaged and dislocated into the anterior space of hip joint. Several attempts to retrieve it failed. The permanent femoral component was inserted, and the wound was closed. The patient was repositioned supine to allow an ilioinguinal approach, and the component was easily removed. She had an uneventful, good recovery. Several cases of intraoperative dislocation of the femoral trial head during total hip arthroplasty have been reported, this is the first report of dislocation of a bipolar trial cup. A previous report described difficulty retrieving a trial cup. We easily removed our trial cup using another approach. It is vital to plan systematically for this frustrating complication.

  15. Congential dislocation of the hip and adult low back pain: a report of three cases

    PubMed Central

    Kitchen, Robert G; Mierau, Dale; Cassidy, David; Dupuis, Pierre

    1988-01-01

    Congenital dislocation of the hip (CDH) in an adult can accompany or cause mechanical low-back pain. This in turn, can create confusion in making the proper diagnosis. The mechanical alterations caused by CDH create an added strain to the lumbosacral spine. Manipulative treatment for back pain in these patients must not subject the dislocated hips to undue torque. ImagesFigure 1Figure 2Figure 3Figure 4aFigure 4b

  16. Repeated posterior dislocation of total hip arthroplasty after spinal corrective long fusion with pelvic fixation.

    PubMed

    Furuhashi, Hiroki; Togawa, Daisuke; Koyama, Hiroshi; Hoshino, Hironobu; Yasuda, Tatsuya; Matsuyama, Yukihiro

    2017-05-01

    Several reports have indicated that anterior dislocation of total hip arthroplasty (THA) can be caused by spinal degenerative changes with excessive pelvic retroversion. However, no reports have indicated that posterior dislocation can be caused by fixed pelvic anteversion after corrective spine surgery. We describe a rare case experiencing repeated posterior THA dislocation that occurred at 5 months after corrective spinal long fusion with pelvic fixation. A 64-year-old woman had undergone bilateral THA at 13 years before presenting to our institution. She had been diagnosed with kyphoscoliosis and underwent three subsequent spinal surgeries after the THA. We finally performed spinal corrective long fusion from T5 to ilium with pelvic fixation (with iliac screws). Five months later, she experienced severe hip pain when she tried to stand up from the toilet, and was unable to move, due to posterior THA dislocation. Therefore, we performed closed reduction under sedation, and her left hip was easily reduced. After the reduction, she started to walk with a hip abduction brace. However, she had experienced 5 subsequent dislocations. Based on our findings and previous reports, we have hypothesized that posterior dislocation could be occurred after spinal corrective long fusion with pelvic fixation due to three mechanisms: (1) a change in the THA cup alignment before and after spinal corrective long fusion surgery, (2) decreased and fixed pelvic posterior tilt in the sitting position, or (3) the trunk's forward tilting during standing-up motion after spinopelvic fixation. Spinal long fusion with pelvic fixation could be a risk factor for posterior THA dislocation.

  17. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    PubMed

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  18. Surgical hip dislocation for treatment of cam femoroacetabular impingement

    PubMed Central

    Chaudhary, Milind M; Chaudhary, Ishani M; Vikas, KN; KoKo, Aung; Zaw, Than; Siddhartha, A

    2015-01-01

    Background: Cam femoroacetabular impingement is caused by a misshapen femoral head with a reduced head neck offset, commonly in the anterolateral quadrant. Friction in flexion, adduction and internal rotation causes limitation of the hip movements and pain progressively leading to labral and chondral damage and osteoarthritis. Surgical hip dislocation described by Ganz permits full exposure of the hip without damaging its blood supply. An osteochondroplasty removes the bump at the femoral head neck junction to recreate the offset for impingement free movement. Materials and Methods: Sixteen patients underwent surgery with surgical hip dislocation for the treatment of cam femoroacetabular impingement by open osteochondroplasty over last 6 years. Eight patients suffered from sequelae of avascular necrosis (AVN). Three had a painful dysplastic hip. Two had sequelae of Perthes disease. Three had combined cam and pincer impingement caused by retroversion of acetabulum. All patients were operated by the trochanteric flip osteotomy with attachments of gluteus medius and vastus lateralis, dissection was between the piriformis and gluteus minimus preserving the external rotators. Z-shaped capsular incision and dislocation of the hip was done in external rotation. Three cases also had subtrochanteric osteotomy. Two cases of AVN also had an intraarticular femoral head reshaping osteotomy. Results: Goals of treatment were achieved in all patients. No AVN was detected after a 6 month followup. There were no trochanteric nonunions. Hip range of motion improved in all and Harris hip score improved significantly in 15 of 16 cases. Mean alpha angle reduced from 86.13° (range 66°–108°) to 46.35° (range 39°–58°). Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term. PMID:26538754

  19. Dislocations

    MedlinePlus

    ... or a blow, sometimes from playing a contact sport. You can dislocate your ankles, knees, shoulders, hips, ... to dislocate it again. Wearing protective gear during sports may help prevent dislocations.

  20. Traumatic anterior shoulder dislocation: a case study of nonoperative management in a mixed martial arts athlete.

    PubMed

    Sims, Kevin; Spina, Andreo

    2009-12-01

    To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program.

  1. Traumatic anterior shoulder dislocation: a case study of nonoperative management in a mixed martial arts athlete

    PubMed Central

    Sims, Kevin; Spina, Andreo

    2009-01-01

    Objective: To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. Clinical Features: A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Intervention and Outcome: Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. Conclusion: This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program. PMID:20037691

  2. Utilization of the Safe Surgical Dislocation Approach of the Hip to Retrieve a Bullet from the Femoral Head

    PubMed Central

    Delaney, Ruth; Albright, Maurice; Rebello, Gleeson

    2011-01-01

    Retained intra-articular missiles from low-velocity handguns can lead to mechanical arthritis, synovitis, and lead toxicity. Various surgical approaches have been described to extract such foreign bodies from the hip joint. We present the case of a 17-year-old male in which the surgical dislocation approach was utilized to retrieve a bullet from the femoral head with a good short-term outcome. This case represents a rare application of the surgical hip dislocation approach for an unusual trauma. PMID:23198205

  3. A syndrome of dislocated hips and radial heads, carpal coalition, and short stature in Puerto Rican children.

    PubMed

    Steel, H H; Piston, R W; Clancy, M; Betz, R R

    1993-02-01

    An orthopaedic syndrome that apparently had not been reported previously was identified in twenty-three children. Characteristics shared by all twenty-three children included Hispanic descent, residence in Puerto Rico, bilateral dislocation of the hip, dislocated radial heads, short stature, and other osseous anomalies. Twelve dislocated hips in six patients were not treated. All of these hips were functioning satisfactorily at the time of the review, but only four of the children had reached skeletal maturity. Sixteen hips in eight patients remained reduced after closed reduction. Of these eight patients, the four who were skeletally immature at the time of the review had a satisfactory result, and the four who were skeletally mature had an unsatisfactory result because of discomfort or fibrous ankylosis. Eighteen hips in nine patients were treated with a reduction augmented by some form of operation. All of these hips redislocated. Of the forty-six elbows in the twenty-three children, thirty-three were dislocated, as seen clinically and radiographically; eight were normal, both clinically and radiographically; and there was dysplasia at the radiocapitellar articulation of the remaining five. Twenty of the twenty-three children were found to have carpal coalitions. Fourteen children had scoliosis, and five of them were managed with spinal arthrodesis and correction. Three patients had an anomaly of the cervical spine, with one deformity causing symptoms and signs that were treated with decompression. Eight patients had talipes cavus bilaterally, which was not treated.

  4. [Therapy of traumatic anterior shoulder dislocation: current status of therapy in Germany. Are there scientifically verified therapy concepts?].

    PubMed

    Tingart, M; Bäthis, H; Bouillon, B; Tiling, T

    2001-06-01

    There are no generally accepted concepts for the treatment of traumatic anterior shoulder dislocation. The objective of this study was to ascertain the current treatment for traumatic shoulder dislocations in German hospitals and to compare this with the data reported in the literature. A total of 210 orthopedic surgery departments were asked for their treatment strategy in an anonymous country-wide survey; 103 questionnaires (49%) were returned for evaluation. Additional imaging (ultrasound, CT, MRI) beyond the routine X-rays is performed in 82% of clinics for primary shoulder dislocation (94% in recurrent dislocation). A young, athletic patient (< 30 years old) would be operated on for a primary traumatic shoulder dislocation in 73% of hospitals (98% in recurrent dislocation). In contrast, a patient of the same age, with a moderate level of sporting activity would be treated conservatively in 67% of cases (14% in recurrent dislocation). Similarly, for an active, middle-aged patient with a demanding job, 74% of responses favored conservative treatment after a primary dislocation and 6% after a recurrent dislocation. Older patients (> 65 years old) are usually treated conservatively after a primary or recurrent shoulder dislocation (99%, 69%). For a primary shoulder dislocation the most popular surgical reconstruction is a Bankart repair (75%). For recurrent shoulder dislocation several different operative techniques are seen (Bankart 29%, T-shift 26%, Putti-Platt 8%, Eden-Lange-Hybbinette 22%, Weber osteotomy 13%). Based on our literature review, we found: (1) The clinical examination of both shoulders is important to diagnose hyperlaxity; (2) Routine CT or MRI is not necessary for primary traumatic shoulder dislocations; (3) A young, athletic patient should undergo surgical reconstruction after a primary shoulder dislocation; (4) The operation of choice for primary and recurrent dislocation is the Bankart repair; (5) There is no sufficient evidence that an arthroscopic Bankart repair is as good as an open procedure; (6) There are limited indications for other operative techniques, as they are associated with a higher recurrence and arthrosis rate.

  5. Surgical dislocation of the hip and the management of femoroacetabular impingement: results of the Christchurch experience.

    PubMed

    Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J

    2011-06-01

    Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.

  6. What Are the Risk Factors for Dislocation of Hip Bipolar Hemiarthroplasty Through the Anterolateral Approach? A Nested Case-control Study.

    PubMed

    Li, Lianhua; Ren, Jixin; Liu, Jia; Wang, Hao; Sang, Qinghua; Liu, Zhi; Sun, Tiansheng

    2016-12-01

    Hip dislocation after treatment of a femoral neck fracture with a hemiarthroplasty remains an important problem in the treatment of hip fractures, but the associations between patient factors and surgical factors, and how these factors contribute to dislocation in patients who have undergone bipolar hemiarthroplasty through an anterolateral approach for femoral neck fracture currently are only poorly characterized. We evaluated patients with bipolar hemiarthroplasty dislocation after surgery for femoral neck fracture treated through an anterolateral approach and asked: (1) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dislocations? (2) What are the frequency, characteristics, and risk factors of bipolar hemiarthroplasty dissociations? A review of hospital records for patients who underwent bipolar hip hemiarthroplasty for femoral neck fracture at one hospital between July 2004 and August 2014 was conducted. During that time, 1428 patients were admitted with a diagnosis of femoral neck fracture; 508 of these patients underwent bipolar hip hemiarthroplasty, of whom 61 died and 23 were lost to followup during the first year, leaving 424 (83%) available for analysis. The remainder of the patients during that time were treated with internal fixation (512), unipoloar hip arthroplasty (17), or THA (391). For each patient with dislocation, we selected five control patients from the cohort according to sex, age (± 3 years), and year of entry in the study to eliminate some confounding factors. We recorded patient characteristics regarding demographics, medical comorbidities, Katz score, American Society of Anesthesiologists score, Mini-Mental State Examination (MMSE) score, and anesthesia type. Medical comorbidities included diabetes, chronic pulmonary disease, heart disease, neuromuscular diseases, and dementia. Univariate analyses were used to search for possible risk factors. Conditional logistic regression analyses on dislocation or dissociation were performed to estimate hazard rates (HRs) and corresponding 95% CIs with covariates of a probability less than 0.1 in univariate analysis. In this cohort, there were 26 dislocations including four that were also dissociations. The proportion of patients experiencing a dislocation was 6% (26 of 424). The mean interval from surgery to dislocation was 56 weeks (range, 0-433 weeks), and 18 dislocations (69%) occurred within 3 months after surgery. Three variables were independently associated with an increased risk of hip dislocation: dementia (HR, 3.51; 95% CI, 1.19-10.38; p = 0.02), discrepancy of offset (HR, 1.72; 95% CI, 1.15-2.58; p = 0.008), and lower MMSE score (HR, 0.93; 95% CI, 0.88-0.98; p = 0.007). The proportion of patients experiencing a dissociation was 0.9% (four of 424). The result of conditional logistic regression for dissociation showed that cup size smaller than 43 mm was the risk factor (HR = 513.05). However, there was no statistical difference with the probability equaling 0.47. After the anterolateral approach for treatment of femoral neck fracture using bipolar hemiarthroplasty, 6% of hips dislocated and 0.9% experienced dissociation. Cognitive dysfunction and discrepancy of offset were independent risk factors associated with an increased risk of prosthetic dislocation. The small cup without a safety ring may be the risk factor of dissociation. Discrepancy of offset should be avoided during the operation by performing an accurate femoral osteotomy and choosing an adequate femoral stem neck length. For patients with cognitive dysfunction and a small cup, suturing the joint capsule during the operation and reinforcing protective measures after surgery might reduce the occurrence of dislocation and dissociation, however a study addressing this is necessary to confirm this. Level III, therapeutic study.

  7. Gross Instability After Hip Arthroscopy: An Analysis of Case Reports Evaluating Surgical and Patient Factors.

    PubMed

    Yeung, Marco; Memon, Muzammil; Simunovic, Nicole; Belzile, Etienne; Philippon, Marc J; Ayeni, Olufemi R

    2016-06-01

    Gross hip instability is a rare complication after hip arthroscopy, and there is limited literature surrounding this topic. This systematic review investigates cases of gross hip instability after arthroscopy and discusses the risk factors associated with this complication. A systematic search was performed in duplicate for studies investigating gross hip instability after hip arthroscopy up to October 2015. Study parameters including sample size, mechanism and type of dislocation, surgical procedure details, patient characteristics, postoperative rehabilitation protocol, and level of evidence were analyzed. The systematic review identified 9 case reports investigating gross hip instability after hip arthroscopy (10 patients). Anterior dislocation occurred in 66.7% of patients, and most injuries occurred with a low-energy mechanism. Common surgical factors cited included unrepaired capsulotomy (77.8%) and iliopsoas release (33.3%), whereas patient factors included female gender (77.8%), acetabular dysplasia (22.2%), and general ligamentous laxity (11.1%). Postoperative restrictions and protocols were variable and inconsistently reported, and their relation to post-arthroscopy instability was difficult to ascertain. This systematic review discussed various patient, surgical, and postoperative risk factors of gross hip instability after arthroscopy. Patient characteristics such as female gender, hip dysplasia, and ligamentous laxity may be risk factors for post-arthroscopy dislocation. Similarly, surgical risk factors for iatrogenic hip instability may include unrepaired capsulotomies and iliopsoas debridement, although the role of capsular closure in iatrogenic instability is not clear. The influences of postoperative restrictions and protocols on dislocation are also unclear in the current literature. Surgeons should be cognizant of these risk factors when performing hip arthroscopy and be mindful that these factors appear to occur in combination. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Patient Needs for an Ambulant Dislocation Alert System Following Total Hip Arthroplasty.

    PubMed

    Huis In't Veld, Rianne; Peters, Anil; Vollenbroek-Hutten, Miriam; Hermens, Hermie; van den Hoven, Carmen

    2018-05-01

    One of the major complications in total hip arthroplasty (THA) is dislocation of the prosthesis. To prevent early dislocation, patients are instructed with movement restrictions. The first goal in this development is to obtain insight in the movement restrictions that are reported to have low levels of self-efficacy during activities of daily life. The second goal is to reveal the design needs for an ambulant hip dislocation alert system (HipDas) and the third goal is to explore its usability among patients. Patient-centered experiences with THA were explored by the use of a questionnaire and a semistructured focus group. The questionnaire was administered among n = 32 THA patients at 1 week preoperative and at 3 and 6 weeks postoperative. The questions addressed self-efficacy, performance and effort expectancy, and usefulness and social influence. The focus group consisted of patient journeys and scenario composition. The usability of a prototype version of the HipDas system was evaluated (n = 5). Flexion of the hip >90°, bending over while sitting in a chair, and sleeping in a supine position are the restrictions that have the lowest self-efficacy. The majority of patients (>86.6%) believe that a future HipDas is useful. Focus group outcomes suggest there is a gradual decrease in the threshold for feedback. The system is preferably used in the first 6 weeks after surgery and appeared to be usable and highly clinically relevant. HipDas is considered an interesting concept that can accelerate functional recovery of patients following THA by providing support on how to properly apply postoperative movement restrictions to prevent a dislocation.

  9. Dislocation of the penis: a rare complication after traumatic pelvic injury

    PubMed Central

    Lim, Mei Chin; Srinivasan, Sivasubramanian; Teh, Hui Seong; Teo, Chang Peng Colin

    2015-01-01

    Traumatic injury to the male external genitalia is frequently encountered, but acute traumatic dislocation of the penile structure is extremely rare, with only a few reports found in the literature. We herein report the case of a 21-year-old man who sustained blunt trauma to the pelvis following a motor vehicle accident, and had features suspicious of penile dislocation. With the use of computed tomography and bedside ultrasonography, a diagnosis of penile dislocation was made, which was subsequently confirmed intraoperatively. Immediate surgical intervention via gentle manipulation of the penile tissue back to its native position was performed in order to restore normal anatomy. The exact mechanism of penile dislocation is not known. However, circumferential laceration around the foreskin causing degloving injury of the penis is suggested in our patient. PMID:25640107

  10. The Power of a Soccer Ball: A Traumatic Open Finger Dislocation-A Rare Case Presentation.

    PubMed

    Dülgeroğlu, Turan Cihan; Metineren, Hasan; Aydın, Ekrem; Dülgeroğlu, Ayşegül

    2015-01-01

    Proximal interphalangeal joint dislocations are injuries observed frequently and caused by axial loading on the finger in the extension. In this paper we present a traumatic open finger dislocation due to a ball hitting a wrestler. It was successfully treated with reduction and the volar plate and collateral bond fixation were applied with absorbable sutures.

  11. Can we prevent hip dislocation in children with cerebral palsy? Effects of postural management.

    PubMed

    Picciolini, Odoardo; LE Métayer, Michel; Consonni, Dario; Cozzaglio, Massimo; Porro, Matteo; Gasparroni, Verusca; Panou, Artemisia; Mosca, Fabio; Portinaro, Nicola M

    2016-10-01

    Hip dislocation is common in children with cerebral palsy (CP). At birth they do not have musculoskeletal deformities but they develop over time due to the combined effects of the movement disorder and impaired gross motor function. Early detection and treatment of a hip at risk is needed to modify the natural of hip development in CP. The aim of this study was to determine the effect of postural management treatment on hip displacement's progression in children CP. Prospective comparative non-randomized study. Rehabilitative outpatient unit. Fifty-one children with CP were studied; the treated group (N.=30) was compared to a control group (N.=21). The treated group followed a two year's long combined treatment program consisting a neurodevelopment treatment (NDT) two times a week and a 5 hours daily siège moulé postural program. The control group underwent only NDT twice a week for two years. Hip radiographs were measured with the migration percentage (MP) method at baseline, at 1 and 2 years of follow-up. A significant difference has been observed in the MP (%) trend (P<0.001) between treatment and control groups. At 2 years, there was a marked worsening (MP from 23.0 to 37.7) in the control group, compared to the stability (from 28.8 to 26.8) in the treatment group. This study supports the evidence that conservative postural management of hip deformity is useful to prevent the natural progression of hip dislocation. Hip radiographic follow up program together with NDT and postural management program is useful to modify the natural progression of hip dislocation in children with CP.

  12. [The hip joint in neuromuscular disorders].

    PubMed

    Strobl, W M

    2009-07-01

    Physiologic motor and biomechanical parameters are prerequisites for normal hip development and hip function. Disorders of muscle activity and lack of weight bearing due to neuromuscular diseases may cause clinical symptoms such as an unstable hip or reduced range of motion. Disability and handicap because of pain, hip dislocation, osteoarthritis, gait disorders, or problems in seating and positioning are dependent on the severity of the disease, the time of occurrence, and the means of prevention and treatment. Preservation of pain-free and stable hip joints should be gained by balancing muscular forces and by preventing progressive dislocation. Most important is the exact indication of therapeutic options such as movement and standing therapy as well as drugs and surgery.

  13. Proximal femoral resection and articulated hip distraction with an external fixator for the treatment of painful spastic hip dislocations in pediatric patients with spastic quadriplegia.

    PubMed

    Lampropulos, Mario; Puigdevall, Miguel H; Zapozko, Daniel; Malvárez, Héctor R

    2008-01-01

    We describe the results obtained with an alternative method of treatment for spastic painful hip dislocations in nonambulatory patients, which consists of a proximal femoral resection with capsular interposition arthroplasty, and the addition of a hinged external fixator for postoperative articulated hip distraction to allow for an immediate upright position and the ability to sit in a wheelchair. We performed this technique in three patients (four hips) with a mean age at the time of surgery of 15 years. Postoperatively, clinical improvement was observed in all four hips, with respect to pain relief, sitting tolerance, perineal care and functional range of motion.

  14. Posterior approach and dislocation rate: a 213 total hip replacements case-control study comparing the dual mobility cup with a conventional 28-mm metal head/polyethylene prosthesis.

    PubMed

    Bouchet, R; Mercier, N; Saragaglia, D

    2011-02-01

    Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  15. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  16. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  17. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  18. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Congenital hip dislocation abduction splint. 890.3665 Section 890.3665 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890...

  19. An evidence-based algorithm for the management of common peroneal nerve injury associated with traumatic knee dislocation

    PubMed Central

    Samson, Deepak; Ng, Chye Yew; Power, Dominic

    2016-01-01

    Traumatic knee dislocation is a complex ligamentous injury that may be associated with simultaneous vascular and neurological injury. Although orthopaedic surgeons may consider CPN exploration at the time of ligament reconstruction, there is no standardised approach to the management of this complex and debilitating complication. This review focusses on published evidence of the outcomes of common peroneal nerve (CPN) injuries associated with knee dislocation, and proposes an algorithm for the management. Cite this article: Deepak Samson, Chye Yew Ng, Dominic Power. An evidence-based algorithm for the management of common peroneal nerve injury associated with traumatic knee dislocation. EFORT Open Rev 2016;1:362-367. DOI: 10.1302/2058-5241.160012. PMID:28461914

  20. Concomitant Posterior Hip Dislocation, Ipsilateral Intertrochanteric- and Proximal Tibial- Fractures with Popliteal Artery Injury: A Challenging Trauma Mélange.

    PubMed

    Chotai, Pranit N; Ebraheim, Nabil A; Hart, Ryan; Wassef, Andrew

    2015-11-05

    Constellation of ipsilateral posterior hip dislocation, intertrochanteric- and proximal tibial fracture with popliteal artery injury is rare. Management of this presentation is challenging. A motor vehicle accident victim presented with these injuries, but without any initial signs of vascular compromise. Popliteal artery injury was diagnosed intra-operatively and repaired. This was followed by external fixation of tibial fracture, open reduction of dislocated hip and internal fixation of intertrochanteric fracture. Patient regained bilateral complete weight bearing and returned to pre-accident activity level. Apt surgical management including early repair of vascular injury in such a trauma mélange allows for a positive postoperative outcome.

  1. Acetabular cup position and risk of dislocation in primary total hip arthroplasty.

    PubMed

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-02-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation - The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies.

  2. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    PubMed Central

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik; Husted, Henrik; Gromov, Kirill

    2017-01-01

    Background and purpose — Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods — A systematic search of literature in the PubMed database was performed (January and February 2016) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results— 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced postoperative dislocation whereas others did not. The majority of articles could not identify a statistically significant difference between dislocating and non-dislocating THA with regard to mean angles of cup anteversion and inclination. Most of the articles that assessed cup placement within the Lewinnek safe zone did not show a statistically significant reduction in dislocation rate. Alternative target ranges have been proposed by several authors. Interpretation— The Lewinnek safe zone could not be justified. It is difficult to draw broad conclusions regarding a definitive target zone for cup positioning in THA, due to variability between studies and the likely multifactorial nature of THA dislocation. Future studies comparing cup positioning and dislocation rate should investigate surgical approach separately. Standardized tools for measurement of cup positioning should be implemented to allow comparison between studies. PMID:27879150

  3. Rocket launcher: A novel reduction technique for posterior hip dislocations and review of current literature.

    PubMed

    Dan, Michael; Phillips, Alfred; Simonian, Marcus; Flannagan, Scott

    2015-06-01

    We provide a review of literature on reduction techniques for posterior hip dislocations and present our experience with a novel technique for the reduction of acute posterior hip dislocations in the ED, 'the rocket launcher' technique. We present our results with six patients with prosthetic posterior hip dislocation treated in our rural ED. We recorded patient demographics. The technique involves placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, in an ergonomically friendly manner for the reducer. We used Fisher's t-test for cohort analysis between reduction techniques. Of our patients, the mean age was 74 years (range 66 to 85 years). We had a 83% success rate. The one patient who the 'rocket launcher' failed in, was a hemi-arthroplasty patient who also failed all other closed techniques and needed open reduction. When compared with Allis (62% success rate), Whistler (60% success rate) and Captain Morgan (92% success rate) techniques, there was no statistically significant difference in the successfulness of the reduction techniques. There were no neurovascular or periprosthetic complications. We have described a reduction technique for posterior hip dislocations. Placing the patient's knee over the shoulder, and holding the lower leg like a 'Rocket Launcher' allow the physician's shoulder to work as a fulcrum, thus mechanically and ergonomically superior to standard techniques. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  4. Right sternoclavicular dislocation after traumatic delivery: a case report.

    PubMed

    Aretz, S; Benz-Bohm, G; Helling, H J; Herkenrath, P; Roth, B

    1999-12-01

    Sternoclavicular (SC) dislocation is an injury that is very rare in the newborn. Thus far there have been no reports describing this in neonates after a traumatic birth injury. This condition can be difficult to differentiate from epiphyseal separation, which occurs more often in older children. For successful treatment, early diagnosis is essential. Timely surgical reposition and fixation with following immobilization is recommended in instances of complete (SC) dislocation. We report a trauma-induced case of SC dislocation in a neonate successfully managed by polydioxanon cord fixation.

  5. Femoroacetabular Impingement Is Associated With Sports-Related Posterior Hip Instability in Adolescents: A Matched-Cohort Study.

    PubMed

    Mayer, Stephanie W; Abdo, João Caetano Munhoz; Hill, Mary K; Kestel, Lauryn A; Pan, Zhaoxing; Novais, Eduardo N

    2016-09-01

    Femoroacetabular impingement (FAI) deformity has been associated with posterior hip instability in adult athletes. To determine if FAI deformity is associated with posterior hip instability in adolescents, the femoral head-neck junction or acetabular structure in a cohort of adolescent patients who sustained a low-energy, sports-related posterior hip dislocation was compared with that in a group of healthy age- and sex-matched controls with no history of hip injury or pain. Cross-sectional study; Level of evidence, 3. We identified 12 male patients (mean age, 13.9 years; range, 12-16 years) who sustained a sports-related posterior hip dislocation and underwent a computed tomography (CT) scan after closed reduction. For each patient, 3 age- and sex-matched healthy controls were identified. Femoral head-neck type was assessed by measurement of the alpha angle on the radially oriented CT images at the 12-, 1-, 2-, and 3-o'clock positions. Age, body mass index (BMI), alpha angle at each position, acetabular version, Tönnis angle, and lateral center-edge angle (LCEA) on the involved hip in the dislocation group were compared with those of the matched controls using a mixed-effects model. A logistic regression analysis using a generalized estimating equation was used to compare the percentage of subjects with cam-type FAI deformity (alpha angle >55°) in each group. The dislocation and control groups were similar in age distribution and BMI (P > .05). The mean alpha angles were statistically significantly higher in the dislocation group compared with the control group at the superior (46.3° ± 1.1° vs 42.7° ± 0.6°; P = .0213), superior-anterior (55.5° ± 1.9° vs 46.0° ± 1.3°; P = .0005), and anterior-superior (54.9° ± 1.5° vs 48.9° ± 1.0°; P = .0045) regions. Cam deformity was present in a larger proportion of patients in the dislocation group than in the control group (P < .0035). An alpha angle greater than 55° was present in 16.7% of the dislocation group and 0% of the control group at the 12-o'clock position (P = .1213), 41.7% versus 0% at the 1-o'clock position (P = .0034), 58% versus 6% at the 2-o'clock position (P = .0004), and 25% versus 2.8% at the 3-o'clock position (P = .0929). Acetabular anteversion was lower in the dislocation group (9.6° ± 1.4°) compared with the control group (15.1° ± 0.8°) (P = .0068). Mean acetabular LCEA was within a normal range in both groups. A significantly higher mean alpha angle from the superior to the anterior-superior regions of the femoral head-neck junction and lower acetabular version were found in adolescents who sustained low-energy, sports-related posterior hip dislocations. © 2016 The Author(s).

  6. A patient-specific model of the biomechanics of hip reduction for neonatal Developmental Dysplasia of the Hip: Investigation of strategies for low to severe grades of Developmental Dysplasia of the Hip.

    PubMed

    Huayamave, Victor; Rose, Christopher; Serra, Sheila; Jones, Brendan; Divo, Eduardo; Moslehy, Faissal; Kassab, Alain J; Price, Charles T

    2015-07-16

    A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Late septic hip dislocation with multifocal osteomyelitis and malaria: a case report.

    PubMed

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2012-12-01

    A 9-year-old boy presented with high-grade fever associated with pain and swelling in right hip and left leg of 1-week duration. Pus was found on diagnostic aspiration of the right hip joint. Emergency arthrotomy was performed through anterior approach with drill holes in proximal femur and culture showed MRSA. Intravenous antibiotics were given for 4 weeks. Patient symptomatically improved in immediate postoperative period and in bed hip mobilization was started. On eighth postoperative day, child developed high-grade intermittent fever with chills and rigors and diagnosed as plasmodium falciparum malaria. Fever subsided with antimalarial treatment. On twenty-first day, patient complained pain in right hip and X-ray showed posterior hip dislocation with osteomyelitis of proximal femur. Closed reduction and hip spica application was done under general anesthesia. At follow-up, the clinical result was fair with resolution of infection and stiff hip.

  8. A Multi-centre Study to Assess the Long-term Performance of the Summit™ Hip in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-08-03

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  9. Avascular necrosis as a complication of the treatment of dislocation of the hip in children with cerebral palsy.

    PubMed

    Koch, A; Jozwiak, M; Idzior, M; Molinska-Glura, M; Szulc, A

    2015-02-01

    We investigated the incidence and risk factors for the development of avascular necrosis (AVN) of the femoral head in the course of treatment of children with cerebral palsy (CP) and dislocation of the hip. All underwent open reduction, proximal femoral and Dega pelvic osteotomy. The inclusion criteria were: a predominantly spastic form of CP, dislocation of the hip (migration percentage, MP > 80%), Gross Motor Function Classification System, (GMFCS) grade IV to V, a primary surgical procedure and follow-up of > one year. There were 81 consecutive children (40 girls and 41 boys) in the study. Their mean age was nine years (3.5 to 13.8) and mean follow-up was 5.5 years (1.6 to 15.1). Radiological evaluation included measurement of the MP, the acetabular index (AI), the epiphyseal shaft angle (ESA) and the pelvic femoral angle (PFA). The presence and grade of AVN were assessed radiologically according to the Kruczynski classification. Signs of AVN (grades I to V) were seen in 79 hips (68.7%). A total of 23 hips (18%) were classified between grades III and V. Although open reduction of the hip combined with femoral and Dega osteotomy is an effective form of treatment for children with CP and dislocation of the hip, there were signs of avascular necrosis in about two-thirds of the children. There was a strong correlation between post-operative pain and the severity of the grade of AVN. ©2015 The British Editorial Society of Bone & Joint Surgery.

  10. Lessons learned from study of congenital hip disease in adults.

    PubMed

    Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi

    2016-12-18

    Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.

  11. On the permanent hip-stabilizing effect of atmospheric pressure.

    PubMed

    Prietzel, Torsten; Hammer, Niels; Schleifenbaum, Stefan; Kaßebaum, Eric; Farag, Mohamed; von Salis-Soglio, Georg

    2014-08-22

    Hip joint dislocations related to total hip arthroplasty (THA) are a common complication especially in the early postoperative course. The surgical approach, the alignment of the prosthetic components, the range of motion and the muscle tone are known factors influencing the risk of dislocation. A further factor that is discussed until today is atmospheric pressure which is not taken into account in the present THA concepts. The aim of this study was to investigate the impact of atmospheric pressure on hip joint stability. Five joint models (Ø 28-44 mm), consisting of THA components were hermetically sealed with a rubber capsule, filled with a defined amount of fluid and exposed to varying ambient pressure. Displacement and pressure sensors were used to record the extent of dislocation related to intraarticular and ambient pressure. In 200 experiments spontaneous dislocations of the different sized joint models were reliably observed once the ambient pressure was lower than 6.0 kPa. Increasing the ambient pressure above 6.0 kPa immediately and persistently reduced the joint models until the ambient pressure was lowered again. Displacement always exceeded half the diameter of the joint model and was independent of gravity effects. This experimental study gives strong evidence that the hip joint is permanently stabilized by atmospheric pressure, confirming the theories of Weber and Weber (1836). On basis of these findings the use of larger prosthetic heads, capsular repair and the deployment of an intracapsular Redon drain are proposed to substantially decrease the risk of dislocation after THA. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty.

    PubMed

    Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray

    2015-03-01

    The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.

  13. Experience of the posterior lip augmentation device in a regional hip arthroplasty unit as a treatment for recurrent dislocation.

    PubMed

    Hoggett, L; Cross, C; Helm, T

    2017-12-01

    Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.

  14. Acute iatrogenic dislocation following hip impingement arthroscopic surgery.

    PubMed

    Matsuda, Dean K

    2009-04-01

    This is the first case report of an iatrogenic anterior hip dislocation after arthroscopic surgery for femoroacetabular impingement with over 1 year of follow-up. This case report describes the clinical course of a patient with symptomatic cam-pincer femoroacetabular impingement. She underwent arthroscopic rim trimming, labral debridement after a failed attempt at labral refixation from suture cut-through, and femoral head-neck resection osteoplasty. The procedure involved supranormal hip distraction for extraction of an iatrogenic loose body (detached metallic radiofrequency probe tip). The patient had an anterior hip dislocation in the recovery room. Immediate closed reduction under general anesthesia and bracing were performed but failed despite the ability to obtain a concentric but grossly unstable reduction. After 3 failed attempts, a mini-open capsulorrhaphy was performed that successfully restored stability. Her postoperative management and outcome are presented. All of the major static stabilizers of the hip (osseous, labral, and capsuloligamentous) were surgically altered, and a multifactorial causation is proposed. Lessons learned are discussed in hopes of minimizing the occurrence of this rare but dramatic complication.

  15. Hip resurfacing in patients under thirty years old: an attractive option for young and active patients.

    PubMed

    Krantz, Nicolas; Miletic, Bruno; Migaud, Henri; Girard, Julien

    2012-09-01

    Metal-on-metal hip resurfacing is offered as an alternative to traditional hip arthroplasty for young, active adults with advanced osteoarthritis. The concept of hip resurfacing is considered very attractive for this specific population (hard-on-hard bearing component with a large femoral head limiting the risk of dislocation, and allowing femoral bone stock preservation). A prospective clinical trial was designed to investigate the outcome of hip resurfacing in young patients (under 30 years old). We studied 24 hips in 22 patients. Mean age at operation was 24.9 years (range 17.1-29.9). No patient was lost to follow-up. There was no revision at average follow-up of 50.6 months (44-59). Mean UCLA activity score improved from 5.5 (1-9) pre-operatively to 7.6 (1-10) postoperatively (p < 0.001). Mean Harris hip score increased from 43.9 (19-67) to 89.3 (55-100) (p < 0.001). Radiological analysis discerned no osteolysis and no implant migration. The absence of short-term complications, such as mechanical failure or dislocation, is encouraging and leads us to think that mid-term results will be satisfactory. Moreover, the specific advantages of hip resurfacing (bone stock preservation, excellent stability, low risk of dislocation, large-diameter head) make the procedure a very attractive option for young subjects.

  16. A Randomised Multi-centre Study to Compare the Long-term Performance of the Future Hip to 3 Other Implants in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis; Perthes Disease

  17. A previously unreported, dominantly inherited syndrome of shortness of stature, ear malformations, and hip dislocation: the coxoauricular syndrome--autosomal or X-linked male-lethal.

    PubMed

    Duca, D; Pană, I; Ciovirnache, M; Simionesu, L; Ispas, I; Maxililian, C

    1981-01-01

    We reported an apparently previously undescribed syndrome, designated the coxoauricular syndrome, in a mother and her 3 daughters, all of whom shared in variable manner shortness of stature, minor vertebral and pelvic changes, dislocated hip(s), and microtia with corresponding hearing loss. The oldest daughter had coincidental Ullrich-Turner syndrome with 46, Xdel(X)(q 13) chromosome constitution. Inheritance of the trait in this family is dominant, either autosomal or X-linked, with hemizygote lethality.

  18. First-time anterior shoulder dislocations: should they be arthroscopically stabilised?

    PubMed Central

    Sedeek, Sedeek Mohamed; Bin Abd Razak, Hamid Rahmatullah; Ee, Gerard WW; Tan, Andrew HC

    2014-01-01

    The glenohumeral joint is inherently unstable because the large humeral head articulates with the small shadow glenoid fossa. Traumatic anterior dislocation of the shoulder is a relatively common athletic injury, and the high frequency of recurrent instability in young athletes after shoulder dislocation is discouraging to both the patient and the treating physician. Management of primary traumatic shoulder dislocation remains controversial. Traditionally, treatment involves initial immobilisation for 4–6 weeks, followed by functional rehabilitation. However, in view of the high recurrence rates associated with this traditional approach, there has been an escalating interest in determining whether immediate surgical intervention can lower the rate of recurrent shoulder dislocation, improving the patient’s quality of life. This review article aims to provide an overview of the nature and pathogenesis of first-time primary anterior shoulder dislocations, the widely accepted management modalities, and the efficacy of primary surgical intervention in first-time primary anterior shoulder dislocations. PMID:25631890

  19. Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

    PubMed Central

    Hassan, Youssef G.; Joukhadar, Nabih I.

    2018-01-01

    Medial epicondyle entrapment after an acute fracture dislocation of the elbow is a common finding in the pediatric population, but a rare finding in adults. We present a case of an adult patient diagnosed with a traumatic fracture dislocation of the elbow joint with intra-articular entrapment of the medial epicondyle. After initial evaluation, closed reduction was done. Stability testing after reduction showed an unstable joint; thus, open reduction and internal fixation was decided. PMID:29666736

  20. Traumatic Posterior Atlantoaxial Dislocation Without Associated Fracture but With Neurological Deficit

    PubMed Central

    Xu, Yong; Li, Feng; Guan, Hanfeng; Xiong, Wei

    2015-01-01

    Abstract Posterior atlantoaxial dislocation without odontoid fracture is extremely rare and often results in fatal spinal cord injury. According to the reported literature, all cases presented mild or no neurologic deficit, with no definite relation to upper spinal cord injury. Little is reported about traumatic posterior atlantoaxial dislocation, with incomplete quadriplegia associated with a spinal cord injury. We present a case of posterior atlantoaxial dislocation without associated fracture, but with quadriplegia, and accompanying epidural hematoma and subarachnoid hemorrhage. The patient underwent gentle traction in the neutral position until repeated cranial computed tomography revealed no progression of the epidural hematoma. Thereafter, the atlantoaxial dislocation was reduced by using partial odontoidectomy via a video-assisted transcervical approach and maintained with posterior polyaxial screw-rod constructs and an autograft. Neurological status improved immediately after surgery, and the patient recovered completely after 1 year. Posterior fusion followed by closed reduction is the superior strategy for posterior atlantoaxial dislocation without odontoid fracture, according to literature. But for cases with severe neurological deficit, open reduction may be the safest choice to avoid the lethal complication of overdistraction of the spinal cord. Also, open reduction and posterior srew-rod fixation are safe and convenient strategies in dealing with traumatic posterior atlantoaxial dislocation patients with neurological deficit. PMID:26512572

  1. Hip arthroscopy using the lateral approach.

    PubMed

    Glick, J M

    1988-01-01

    The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.

  2. Postural asymmetries in young adults with cerebral palsy.

    PubMed

    Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena

    2013-11-01

    The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Cross-sectional data of 102 people (63 males, 39 females; age range 19-23 y, median 21 y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman's correlation. At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (r(s) =0.48), sitting (r(s) =0.40), standing (r(s) =0.41), and inability to change position: supine (r(s) =0.60), sitting (r(s) =0.73), and standing (r(s) =0.64). Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. © 2013 The Authors. Developmental Medicine & Child Neurology published by John Wiley & Sons Ltd on behalf of Mac Keith Press.

  3. Postural asymmetries in young adults with cerebral palsy

    PubMed Central

    Rodby-Bousquet, Elisabet; Czuba, Tomasz; Hägglund, Gunnar; Westbom, Lena

    2013-01-01

    Aim The purpose was to describe posture, ability to change position, and association between posture and contractures, hip dislocation, scoliosis, and pain in young adults with cerebral palsy (CP). Methods Cross-sectional data of 102 people (63 males, 39 females; age range 19–23y, median 21y) out of a total population with CP was analysed in relation to Gross Motor Function Classification System (GMFCS) levels I (n=38), II (n=21), III (n=13), IV (n=10), and V (n=20). The CP subtypes were unilateral spastic (n=26), bilateral spastic (n=45), ataxic (n=12), and dyskinetic CP (n=19). The Postural Ability Scale was used to assess posture. The relationship between posture and joint range of motion, hip dislocation, scoliosis, and pain was analysed using logistic regression and Spearman’s correlation. Results At GMFCS levels I to II, head and trunk asymmetries were most common; at GMFCS levels III to V postural asymmetries varied with position. The odds ratios (OR) for severe postural asymmetries were significantly higher for those with scoliosis (OR=33 sitting), limited hip extension (OR=39 supine), or limited knee extension (OR=37 standing). Postural asymmetries correlated to hip dislocations: supine (rs=0.48), sitting (rs=0.40), standing (rs=0.41), and inability to change position: supine (rs=0.60), sitting (rs=0.73), and standing (rs=0.64). Conclusions Postural asymmetries were associated with scoliosis, hip dislocations, hip and knee contractures, and inability to change position. This article is commented on by Novak on page 974 of this issue. PMID:23834239

  4. Preservation of the articular capsule and short lateral rotator in direct anterior approach to total hip arthroplasty.

    PubMed

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko; Morohashi, Itaru

    2018-03-09

    In total hip arthroplasty via a direct anterior approach, the femur must be elevated at the time of femoral implant placement. For adequate elevation, division of the posterior soft tissues is necessary. However, if we damage and separate the posterior muscle tissue, we lose the benefits of the intermuscular approach. Furthermore, damage to the posterior soft tissue can result in posterior dislocation. We investigate that protecting the posterior soft tissue increases the joint stability in the early postoperative period and results in a lower dislocation rate. We evaluated muscle strength recovery by measuring the maximum width of the internal obturator muscle on CT images (GE-Healthcare Discovery CT 750HD). We compared the maximum width of the muscle belly preoperatively versus 10 days and 6 months postoperatively. As clinical evaluations, we also investigated the range of motion of the hip joint, hip joint function based on the Japanese Orthopaedic Association hip score (JOA score), and the dislocation rate 6 months after surgery. The width of the internal obturator muscle increased significantly from 15.1 ± 3.1 mm before surgery to 16.4 ± 2.8 mm 6 months after surgery. The JOA score improved significantly from 50.8 ± 15.1 points to 95.6 ± 7.6 points. No dislocations occurred in this study. We cut only the posterosuperior articular capsule and protected the internal obturator muscle to preserve muscle strength. We repaired the entire posterosuperior and anterior articular capsule. These treatments increase joint stability in the early postoperative period, thus reducing the dislocation rate. Therapeutic, Level IV.

  5. Patterns of postural deformity in non-ambulant people with cerebral palsy: what is the relationship between the direction of scoliosis, direction of pelvic obliquity, direction of windswept hip deformity and side of hip dislocation?

    PubMed

    Porter, David; Michael, Shona; Kirkwood, Craig

    2007-12-01

    To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.

  6. Patterns of postural deformity in non-ambulant people with cerebral palsy: what is the relationship between the direction of scoliosis, direction of pelvic obliquity, direction of windswept hip deformity and side of hip dislocation?

    PubMed Central

    Michael, Shona; Kirkwood, Craig

    2008-01-01

    Objective: To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Design: Cross-sectional observational study. Setting: Posture management services in three centres in the UK. Subjects: Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Main measures: Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. Results: A total of 747 participants were included in the study, aged 6–80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P < 0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P = 0.007), hips subluxed on the left (P = 0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P = 0.03) were observed. Conclusions: The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed. PMID:18042604

  7. Outcomes after salvage procedures for the painful dislocated hip in cerebral palsy.

    PubMed

    Wright, Patrick B; Ruder, John; Birnbaum, Mark A; Phillips, Jonathan H; Herrera-Soto, Jose A; Knapp, Dennis R

    2013-01-01

    The painful dislocated hip in the setting of cerebral palsy is a challenging problem. Many surgical procedures have been reported to treat this condition with varying success rates. The purpose of this study is to retrospectively evaluate and compare the outcomes of 3 different surgical procedures performed at our institution for pain relief in patients with spastic quadriplegic cerebral palsy and painful dislocated hips. A retrospective chart review of the surgical procedures performed by 5 surgeons for spastic, painful dislocated hips from 1997 to 2010 was performed. The procedures identified were (1) proximal femoral resection arthroplasty (PFRA); (2) subtrochanteric valgus osteotomy (SVO) with femoral head resection; and (3) proximal femur prosthetic interposition arthroplasty (PFIA) using a humeral prosthesis. Outcomes based on pain and range of motion were determined to be excellent, good, fair, or poor by predetermined criteria. Forty-four index surgeries and 14 revision surgeries in 33 patients with an average follow-up of 49 months met the inclusion criteria. Of the index surgeries, 12 hips were treated with a PFRA, 21 with a SVO, and 11 with a PFIA. An excellent or good result was noted in 67% of PFRAs, 67% of SVOs, and 73% of PFIAs. No statistical significance between these procedures was achieved. The 14 revisions were performed because of a poor result from previous surgery, demonstrating a 24% reoperation rate overall. No patients classified as having a fair result underwent revision surgery. All patients receiving revision surgery were eventually classified as having an excellent or good result. Surgical treatment for the painful, dislocated hip in the setting of spastic quadriplegic cerebral palsy remains unsettled. There continue to be a large percentage of failures despite the variety of surgical techniques designed to treat this problem. These failures can be managed, however, and eventually resulted in a good outcome. We demonstrated a trend toward better outcomes with a PFIA, but further study should be conducted to prove statistical significance. III.

  8. Right upper limb bud triplication and polythelia, left sided hemihypertrophy and congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis: disorganisation-like spectrum or patterning gene defect?

    PubMed

    Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I

    1995-07-01

    A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed.

  9. Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

    PubMed

    Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer

    2014-01-01

    Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Ligamentum teres tenodesis in medial approach open reduction for developmental dislocation of the hip.

    PubMed

    Bache, Christopher Edward; Graham, H Kerr; Dickens, D Robert V; Donnan, Leo; Johnson, Michael B; Nattrass, Gary; O'Sullivan, Mark; Torode, Ian P

    2008-09-01

    When closed reduction of a developmental dislocation of the hip fails, some form of open reduction is required. In recent years, the many advantages of the medial approach open reduction have been emphasized. However, there have been suggestions that the rate of growth disturbance in the proximal femur and the requirement for secondary surgical procedures may be higher with this route than with others. The purpose of this study was to investigate the efficacy and safety of a modified medial approach open reduction, in which the stability of the reduction is enhanced by resection of the redundant ligamentum teres and suturing of the stump of the tendon to the anteromedial capsule. The hospital records and radiographs of 92 infants and children with 109 dislocated hips were reviewed retrospectively. Key demographic and pretreatment data were collected by the first author and compared with the outcome at the most recent follow-up. In addition, 69 children returned for a clinical evaluation by the first author. The outcome at the most recent follow-up was graded according to Severin, and associations were sought between pretreatment grade of dislocation according to Tonnis, the presence of ossific nucleus, changes in the acetabular index, the requirements for secondary surgery, associations with previous treatment, and the position of abduction in the postoperative cast. At a mean follow-up of 9 years, 89% of hips were classified as Severin grade 1 or 2. Avascular necrosis (AVN) was classified according to the system of Kalamchi and MacEwen. The incidence of AVN was 41%, but two thirds of these were grade 1 (temporary irregular ossification), and the Severin grading in these hips was not compromised. The presence of ossification in the capital epiphysis and a range of abduction of less than 60 degrees in the hip spica were noted to be protective against the development of AVN. Three hips redislocated and required additional treatment. Thirty-eight hips required a total of 44 additional surgical procedures. We have demonstrated that it is possible to use a medial approach for open reduction of the congenitally dislocated hip in combination with tenodesis of the ligamentum teres to the anteromedial joint capsule. The incidence of growth disturbance in the proximal femur is high and cumulative with long-term follow-up. However, in this large series, the rate of hip stability, growth disturbance, and need for secondary surgery are comparable to other series. We conclude that the many advantages of open reduction by the medial approach outweigh the disadvantages.

  11. Nationwide multicenter follow-up cohort study of hip arthroplasties performed for osteonecrosis of the femoral head.

    PubMed

    Kobayashi, Seneki; Kubo, Toshikazu; Iwamoto, Yukihide; Fukushima, Wakaba; Sugano, Nobuhiko

    2018-05-12

    To identify modifiable factors related to post-operative dislocation and reoperation in patients with osteonecrosis of the femoral head (ONFH) in a large cohort. We studied 4995 hip arthroplasties: total hip arthroplasty (THA) was performed in 79% of patients; bipolar hemiarthroplasty (BP), 17%; total resurfacing arthroplasty (tRS), 3%; and hemi-resurfacing arthroplasty (hRS), 1%. A new type of BP (accounting for 49% of BPs) comprised a femoral component with a polished or smooth, small-diameter (approximately 10 mm) neck with a round or oval axial cut surface and no sharp corners. The infection rate was relatively low (0.56%) even though 58% of cases of ONFH were associated with systemic steroid use, a known risk factor for infection. Post-operative dislocation occurred in 4.3% of cases, with re-operation needed in 3.9%. The dislocation rate was related to surgery type: 5.2% in THA, 0.9% in BP, and 0% in tRS and hRS. Among total arthroplasties with six month or longer follow-up (3670 THAs and 159 tRSs), the risk factors for post-operative dislocation were younger (≤ 40 years) or older (≥ 62 years) age, higher body weight, posterolateral approach, and smaller prosthetic head diameter. Regarding the need for re-operation, higher body weight and surgery type were identified as risk factors. The relatively high dislocation rate of 5.2% in THA is a cause for concern. The identified risk factors for dislocation should be considered when selecting THA for treatment. Prosthesis survivorship in hRSs was inferior to that in BPs or THAs. Body weight also affected the survivorship of hip arthroplasties.

  12. Cementless total hip arthroplasty for severely dislocated hips previously treated with Schanz osteotomy of the proximal femur.

    PubMed

    Akman, Yunus Emre; Yavuz, Umut; Çetinkaya, Engin; Gür, Volkan; Gül, Murat; Demir, Bilal

    2018-03-01

    We report the short-term outcomes of total hip arthroplasty(THA) in patients previously treated with Schanz osteotomy (SO). Eighteen patients [2 male, 16 female; mean age, 55.4 (range, 50-66) years] who had undergone THA after SO were retrospectively evaluated. Clinical evaluation was performed based on the Harris hip score. Radiological evaluation was performed using full-length radiographs of the lower extremities, pelvis, and hip. The mean follow-up period was 30.8 (range, 18-56) months. Mean femoral shortening was 3.7 (range, 2-5) cm. Perioperative complications occurred in 4 (22.2%) patients. Nonunion was not found at the osteotomy sites. No dislocation was observed. The Trendelenburg sign was positive for five (27.7%) patients, postoperatively. The mean Harris hip score improved from 42.7 to 78.7 (p < 0.05). THA for hips previously treated with SO is technically demanding. If careful preoperative planning is performed, successful treatment can be achieved.

  13. Screening for developmental dysplasia of the hip.

    PubMed

    Desprechins, B; Ernst, C; de Mey, J

    2007-01-01

    The reported prevalence of established dislocation the hip in an unscreened population varies from 0.7 to 1.6 / 1000 children in European and American white populations. In clinically screened populations neonatal hip instability is reported to occur in 3 to 30 / 1000 newborns while established congenital dislocation has a prevalence of 0.1- 4/1000 of which 1/1000 is judged to be in need for surgery. Early diagnosis of DDH is essential for successful treatment and later prognosis of the disorder. Combined procedure including evaluation of both hip morphology and hip stability is currently recommended. Opinions differ about the need for universal versus selective sonographic screening for diagnosis of DDH. Currently selective screening of those infants with recognised risk factors and those with abnormal physical examination would be cost-effective and the only practicable method for most countries.

  14. Right upper limb bud triplication and polythelia, left sided hemihypertrophy and congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis: disorganisation-like spectrum or patterning gene defect?

    PubMed Central

    Sabry, M A; al-Saleh, Q; al-Saw'an, R; al-Awadi, S A; Farag, T I

    1995-01-01

    A Somali female baby with right upper limb triplication, polythelia, left sided hemihypertrophy, congenital hip dislocation, facial dysmorphism, congenital heart disease, and scoliosis is described. It seems that the above described pattern of anomalies has not been reported before. The possible developmental genetic mechanism responsible for this phenotype is briefly discussed. Images PMID:7562971

  15. Dislocation and spontaneous reduction of the femoral implant against the femoral neck in an infected metal on metal hip resurfacing with complex collection.

    PubMed

    Tins, Bernhard

    2011-07-01

    Metal on metal resurfacing hip implants are known to have complications unique to this type of implant. The case presented adds a further previously not described complication, the dislocation and spontaneous reduction of the pin of the femoral component against the femoral neck. The radiographic and CT findings are demonstrated. The dislocation was aided by bone loss due to an infection with a large periarticular collection. Periarticular collections in hip resurfacings are often due to a hypersensitivity type reaction to metal debris. However in the case presented it was due to infection. MRI was not able to discern the infection from a sterile collection. CT demonstrated bone loss and periosteal reaction suggestive of infection. In addition calcification of the pseudocapsule was seen, this is not a recognized feature of sterile collections. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  16. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    PubMed

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A revision procedure was necessary for one patient during the 4(th) year because of a fracture of the polyethylene insert on a metal-back cup; the insert alone was changed. Excepting the patient with infection, there were no cases of certain or probable loosening during the follow-up. The tripolar prosthesis with a mobile cup and a large-diameter head appears to be a reliable solution for these severely unstable hips. The procedure can often be limited to the acetabular component, reducing morbidity. The thickness of the polyethylene cup is a limitation which may affect long-term survival. Search for a highly wear-resistant couple continues.

  17. Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.

    PubMed

    Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc

    2017-06-01

    To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Dwarfism

    MedlinePlus

    ... dwarfism might have: cleft palate hand and ear differences hip dysplasia club feet severe curvature of the spine early deterioration of joints and joint stiffness potential hip and knee dislocation Complications From Spondyloepiphyseal Dysplasia ...

  19. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  20. Overhead Bryant's Traction Does Not Improve the Success of Closed Reduction or Limit AVN in Developmental Dysplasia of the Hip.

    PubMed

    Sucato, Daniel J; De La Rocha, Adriana; Lau, Karlee; Ramo, Brandon A

    2017-03-01

    Preoperative Bryant's overhead traction before closed reduction (CR) in developmental dysplasia of the hip (DDH) remains controversial and its success in increasing CR rates and reducing avascular necrosis (AVN) rates has not been specifically reported in a large cohort. IRB-approved retrospective study of patients (below 3 y)who were treated with attempted CR for idiopathic DDH from 1980 to 2009. Successful CR was defined as a hip that remained reduced and did not require repeat CR or open reduction. Patients were grouped by age, hip instability [Ortolani positive (reducible) vs. fixed dislocation], and Tonnis classification and rates of successful CR were compared between groups with P<0.05. A total of 342 hips were included with a mean age of 0.9 years (0.2 to 2.8 y) and a mean follow-up of 10.4 years (2.0 to 27.7 y). There were 269 hips with fixed dislocations and 73 Ortolani-positive hips. Traction was used in 276 hips. There was no difference in traction utilization in the 3 age groups (below 1, below 1.5, and below 2 y) for either Ortolani-positive hips (P=0.947) or fixed dislocations (P=0.943). There was no difference in achieving a successful CR comparing traction (60.9%) and no-traction groups (60.6%) (P=1.00). For Ortolani-positive hips, traction did not improve the incidence of a successful CR for any age group: below 1 year: P=0.19; below 1.5 years: P=0.23; and below 2 years: P=0.25. Similarly, fixed dislocation patients had no benefit from traction: below 1 year: P=0.76; below 1.5 years: P=0.82; and below 2 years: P=0.85. Tonnis classification did predict success of CR but had no influence on traction success. There was no difference in the rate of AVN between the traction (18%) and no-traction (8%) groups for all patients (P=0.15). In this retrospective series, preoperative Bryant's traction does not improve the rate of a successful CR for patients with DDH and has no protective effect on the development of AVN of the femoral head. These results suggest that Bryant's overhead traction may not be warranted for patients below 3 years of age with DDH. Level III.

  1. Effect of femoral head size and surgical approach on risk of revision for dislocation after total hip arthroplasty

    PubMed Central

    Zijlstra, Wierd P; De Hartog, Bas; Van Steenbergen, Liza N; Scheurs, B Willem; Nelissen, Rob G H H

    2017-01-01

    Background and purpose Recurrent dislocation is the commonest cause of early revision of a total hip arthropasty (THA). We examined the effect of femoral head size and surgical approach on revision rate for dislocation, and for other reasons, after total hip arthroplasty (THA). Patients and methods We analyzed data on 166,231 primary THAs and 3,754 subsequent revision THAs performed between 2007 and 2015, registered in the Dutch Arthroplasty Register (LROI). Revision rate for dislocation, and for all other causes, were calculated by competing-risk analysis at 6-year follow-up. Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results Posterolateral approach was associated with higher dislocation revision risk (HR =1) than straight lateral, anterolateral, and anterior approaches (HR =0.5–0.6). However, the risk of revision for all other reasons (especially stem loosening) was higher with anterior and anterolateral approaches (HR =1.2) and lowest with posterolateral approach (HR =1). For all approaches, 32-mm heads reduced the risk of revision for dislocation compared to 22- to 28-mm heads (HR =1 and 1.6, respectively), while the risk of revision for other causes remained unchanged. 36-mm heads increasingly reduced the risk of revision for dislocation but only with the posterolateral approach (HR =0.6), while the risk of revision for other reasons was unchanged. With the anterior approach, 36-mm heads increased the risk of revision for other reasons (HR =1.5). Interpretation Compared to the posterolateral approach, direct anterior and anterolateral approaches reduce the risk of revision for dislocation, but at the cost of more stem revisions and other revisions. For all approaches, there is benefit in using 32-mm heads instead of 22- to 28-mm heads. For the posterolateral approach, 36-mm heads can safely further reduce the risk of revision for dislocation. PMID:28440704

  2. A Two Centre Study to Assess the Stability and Long-term Performance of the C-Stem™ AMT in a Total Primary Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  3. A Randomised Single Centre Study to Compare the Long-term Wear Characteristics of Marathon™ and Enduron™ Polyethylene Cup Liners in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  4. Assessment of Diagnostic Value of Single View Dynamic Technique in Diagnosis of Developmental Dysplasia of Hip: A Comparison with Static and Dynamic Ultrasond Techniques

    PubMed Central

    Alamdaran, Seyed Ali; Kazemi, Sahar; Parsa, Ali; Moghadam, Mohammad Hallaj; Feyzi, Ali; Mardani, Reza

    2016-01-01

    Background: Developmental dysplasia of hip (DDH) is a common childhood disorder, and ultrasonography examination is routinely used for screening purposes. In this study, we aimed to evaluate a modified combined static and dynamic ultrasound technique for the detection of DDH and to compare with the results of static and dynamic ultrasound techniques. Methods: In this cross-sectional study, during 2013- 2015, 300 high-risk infants were evaluated by ultrasound for DDH. Both hips were examined with three techniques: static, dynamic and single view static and dynamic technique. Statistical analysis was performed using SPSS version 11.5. Results: Patients aged 9 days to 83 weeks. 75% of the patients were 1 to 3 months old. Among 600 hip joints, about 5% were immature in static sonography and almost all of them were unstable in dynamic techniques. 0.3% of morphologically normal hips were unstable in dynamic sonography and 9% of unstable hips had normal morphology. The mean β angle differences in coronal view before and after stress maneuver was 14.43±5.47° in unstable hips. Single view static and dynamic technique revealed that all cases with acetabular dysplasia, instability and dislocation, except two dislocations, were detected by dynamic transverse view. For two cases, Ortolani maneuver showed femoral head reversibility in dislocated hips. Using single view static and dynamic technique was indicative and applicable for detection of more than 99% of cases. Conclusion: Single view static and dynamic technique not only is a fast and easy technique, but also it is of high diagnostic value in assessment of DDH. PMID:27847852

  5. The rate of dislocation is not increased when minimal precautions are used after total hip arthroplasty using the posterolateral approach: a prospective, comparative safety study.

    PubMed

    Kornuijt, A; Das, D; Sijbesma, T; van der Weegen, W

    2016-05-01

    In order to prevent dislocation of the hip after total hip arthroplasty (THA), patients have to adhere to precautions in the early post-operative period. The hypothesis of this study was that a protocol with minimal precautions after primary THA using the posterolateral approach would not increase the short-term (less than three months) risk of dislocation. We prospectively monitored a group of unselected patients undergoing primary THA managed with standard precautions (n = 109, median age 68.9 years; interquartile range (IQR) 61.2 to 77.3) and a group who were managed with fewer precautions (n = 108, median age 67.2 years; IQR 59.8 to 73.2). There were no significant differences between the groups in relation to predisposing risk factors. The diameter of the femoral head ranged from 28 mm to 36 mm; meticulous soft-tissue repair was undertaken in all patients. The medical records were reviewed and all patients were contacted three months post-operatively to confirm whether they had experienced a dislocation. There were no dislocations in the less restricted group and one in the more restricted group (p = 0.32). For experienced surgeons using the posterolateral approach at THA and femoral heads of diameter ≥ 28 mm, it appears safe to manage patients in the immediate post-operative period with minimal precautions to protect against dislocation. Larger studies with adequate statistical power are needed to verify this conclusion. Experienced orthopaedic surgeons using the posterolateral approach for THA should not fear an increased dislocation rate if they manage their patients with a minimal precautions protocol. Cite this article: Bone Joint J 2016;98-B:589-94. ©2016 The British Editorial Society of Bone & Joint Surgery.

  6. Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury

    PubMed Central

    Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan

    2009-01-01

    Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618

  7. 21 CFR 890.3665 - Congenital hip dislocation abduction splint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890... abduction splint is a device intended for medical purposes to stabilize the hips of a young child with...

  8. A Randomised Single Centre Study to Compare the Long-term Performance of 4 Designs of the DePuy Ultima LX Stem in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-05-09

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorder; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  9. A Study to Assess the Long-term Performance of SmartSet® HV and SmartSet® GHV Bone Cements in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-03-02

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  10. A Single Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Ceramic-on-ceramic Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  11. A Multi-centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Polyethylene-on-metal Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-06-27

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  12. A Two Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Metal-on-Metal Bearing in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  13. Prosthetic hip dislocations: is relocation in the emergency department by emergency medicine staff better?

    PubMed

    Lawrey, Emma; Jones, Peter; Mitchell, Robin

    2012-04-01

    Prosthetic hip dislocation is common. This study compares prosthetic hip relocations attempted within the ED by emergency doctors and those under orthopaedic care in the ED or operating theatre (OT). Retrospective cohort study of patients presenting to Auckland City Hospital Adult Emergency Department with prosthetic hip dislocations between 1 January 2003 and 14 April 2008. Primary outcomes were proportion of successful relocation attempts and length of hospital stay. Secondary outcomes were: time to relocation, complications, post-procedural advice, representation rate and long-term outcomes for first-time dislocations. There were 410 eligible presentations during the study period. Emergency medicine (EM) was successful in 254/323 attempts (79%, 95% confidence interval [CI] 74-83). Orthopaedics were successful in 25/35 reductions in the ED (71%, 95% CI 55-84) and 49/51 OT attempts (96%, 95% CI 86-100), P = 0.004 for location OT versus ED. Median times to discharge were 8.8 h for EM, 28.3 h for orthopaedics in the ED and 81 h for orthopaedics in the OT, P < 0.001 for EM versus orthopaedics. Mechanical complications of procedures and early redislocations were infrequent. Complication of sedation were more often seen in OT compared to ED (23/47 [49%, 95% CI 35-63]vs 37/318 [12%, 95% CI 9-16]). There was no difference between EM and orthopaedics in the proportion of hips successfully relocated or complications in the ED; however, EM patients were discharged much sooner, with important resource implications. Procedures carried out in the OT were more successful than in the ED but resulted in prolonged hospital stays and were associated with more complications. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  14. Hip joint biomechanics in those with and without post-traumatic knee osteoarthritis after anterior cruciate ligament injury.

    PubMed

    Wellsandt, E; Zeni, J A; Axe, M J; Snyder-Mackler, L

    2017-12-01

    Anterior cruciate ligament injury results in altered kinematics and kinetics in the knee and hip joints that persist despite surgical reconstruction and rehabilitation. Abnormal movement patterns and a history of osteoarthritis are risk factors for articular cartilage degeneration in additional joints. The purpose of this study was to determine if hip joint biomechanics early after anterior cruciate ligament injury and reconstruction differ between patients with and without post-traumatic knee osteoarthritis 5years after reconstruction. The study's rationale was that individuals who develop knee osteoarthritis after anterior cruciate ligament injury may also demonstrate large alterations in hip joint biomechanics. Nineteen athletes with anterior cruciate ligament injury completed standard gait analysis before (baseline) and after (post-training) extended pre-operative rehabilitation and at 6months, 1year, and 2years after reconstruction. Weightbearing knee radiographs were completed 5years after reconstruction to identify medial compartment osteoarthritis. Five of 19 patients had knee osteoarthritis at 5years after anterior cruciate ligament reconstruction. Patients with knee osteoarthritis at 5years walked with smaller sagittal plane hip angles (P: 0.043) and lower sagittal (P: 0.021) and frontal plane (P: 0.042) external hip moments in the injured limb before and after reconstruction compared to those without knee osteoarthritis. The current findings suggest hip joint biomechanics may be altered in patients who develop post-traumatic knee osteoarthritis. Further study is needed to confirm whether the risk of non-traumatic hip pathology is increased after anterior cruciate ligament injury and if hip joint biomechanics influence its development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Actis Total Hip System 2 Year Follow-up

    ClinicalTrials.gov

    2017-08-14

    Osteoarthritis; Traumatic Arthritis; Rheumatoid Arthritis; Congenital Hip Dysplasia; Avascular Necrosis of the Femoral Head; Acute Traumatic Fracture of the Femoral Head or Neck; Certain Cases of Ankylosis; Non-union of Femoral Neck Fractures; Certain High Sub-Capital & Femoral Neck Fractures in Elderly

  16. [Derotational subtrochanteric osteotomy of the femur in celebral palsy patients].

    PubMed

    Schejbalová, A

    2006-10-01

    Derotational subtrochanteric osteotomy as an independent surgical procedure is one of the options for treatment of hip anteversion in adolescent patients with cerebral palsy. In other indications it is one of combined surgical procedures for hip joint reconstruction. During the 1992-2005 period, derotational subtrochanteric osteotomy was indicated in 74 cases, in ambulatory patients 9 to 18 years old, with diplegic or hemiplegic cerebral plasy. In 63 cases it was used a part of combined surgery. The postoperative evaluation was based on clinical and radiographic findings, migration rates and Wiberg's CE angle obtained at 2 and 6 months, and then at each 6 months following surgery. Derotational subtrochanteric osteotomy alone always resulted in improvement of clinical status and an increase in Wiberg's CE angle by 10 degrees on average. Patients with marginal or high dislocation showed best results when the hip joint was reconstructed before the age of 9 years. In three hips a recurrent dislocation occurred gradually within one year of surgery. These patients fell back to stage II of the Vojta classification found preoperatively. During the next three years, three more hips developed a recurrent dislocation and two showed lateralization (20 %). Reconstructive surgery for neurogenic dislocation in patients over 10 years of age is associated with problems, as is derotation combined with varus osteotomy in abductor insufficiency. On the other hand, derotational subtrochanteric osteotomy alone is indicated particularly in children over 10 years, in whom it corrects hip joint anteversion and improves gait. Complete reconstructive procedures should be considered in the first 10 years of life when neither the femoral head nor the acetabulum are markedly changed. Derotative osteotomy alone is preferred to procedures combined with varus osteotomy. In walking adolescent patients, derotative femoral osteotomy alone is recommended; this can exceptionally be used at earlier age if marked asymmetry is present.

  17. [Effect of abducens orthosis combined with walker on developmental dysplasia of the hip].

    PubMed

    Hu, Zhiyong; Xu, Yongqiang; Liang, Jieyu; Li, Kanghua; Liao, Qiande

    2009-07-01

    To evaluate the effect of abducens orthosis combined with walker on developmental dysplasia of the hip (DDH). A total of 126 patients (224 hips) with DDH aged 6-36 months in Xiangya Hospital was randomly divided into 2 groups: an orthosis combined with walker group and an improved hip frog cast fixation group. Seventy patients (130 hips) were treated by the orthosis combined with walker and 56 patients (94 hips) were treated by the improved hip frog cast fixation. We compared the effect and complications of the 2 groups. The fineness rates of the orthosis combined with walker group and the improved hip frog cast fixation group were 89.2% and 90.4%, respectively, with no significant difference (P>0.05). The rate of femoral head osteonecrosis in the orthosis combined with walker group was significantly lower than that in the improved hip frog cast fixation group (1.5% vs. 5.3%,P<0.05), but the re-dislocation rate in the former was significantly higher than that in the latter (6.9% vs. 1.1 %, P<0.05). Both methods are effective for DDH. Orthosis combined with walker has a lower proportion of femoral head osteonecrosis, but a higher proportion of re-dislocation.

  18. Perthes' disease or late avascular necrosis after developmental dislocation of the hip? 10 children followed for 6-35 years.

    PubMed

    Koczewski, P; Napiontek, M

    2001-08-01

    We studied 10 patients treated because of late avascular necrosis (AVN) mimicking Legg-Calvé-Perthes' disease (LCPD) after developmental dislocation of the hip (DDH). DDH was recognized late at an average age of 5.4 months and in all children it was treated without surgery. In 4 children, the treatment was complicated by mild AVN of the femoral head, which had disappeared before 3 years of age. The first clinical signs of LCPD were noted at a mean age of 5.8 years. They all had Catterall's type III or IV of LCPD. The course was typical of LCPD. 8 children were operated on at mean age of 7.4 (5-12) years. In 7 of them, subtrochanteric derotation-varisation osteotomy of the femur with shortening combined mainly with Dega's pelvic osteotomy was done. The operative treatment resulted in a concentric position of the femoral head and good coverage of the acetabulum. Follow-ups were done at 10 (6-35) years. Shortened femoral neck and trochanteric overgrowth occurred in 4 operated hips. According to the Stulberg classification, 2 hips were classified as type I, 1 as I/II, 5 as II/I as II/III and 1 as IV. We conclude that LCPD mimicking late AVN can occur in hips treated because of developmental dislocation.

  19. Evaluation and Referral for Developmental Dysplasia of the Hip in Infants.

    PubMed

    Shaw, Brian A; Segal, Lee S

    2016-12-01

    Developmental dysplasia of the hip (DDH) encompasses a wide spectrum of clinical severity, from mild developmental abnormalities to frank dislocation. Clinical hip instability occurs in 1% to 2% of full-term infants, and up to 15% have hip instability or hip immaturity detectable by imaging studies. Hip dysplasia is the most common cause of hip arthritis in women younger than 40 years and accounts for 5% to 10% of all total hip replacements in the United States. Newborn and periodic screening have been practiced for decades, because DDH is clinically silent during the first year of life, can be treated more effectively if detected early, and can have severe consequences if left untreated. However, screening programs and techniques are not uniform, and there is little evidence-based literature to support current practice, leading to controversy. Recent literature shows that many mild forms of DDH resolve without treatment, and there is a lack of agreement on ultrasonographic diagnostic criteria for DDH as a disease versus developmental variations. The American Academy of Pediatrics has not published any policy statements on DDH since its 2000 clinical practice guideline and accompanying technical report. Developments since then include a controversial US Preventive Services Task Force "inconclusive" determination regarding usefulness of DDH screening, several prospective studies supporting observation over treatment of minor ultrasonographic hip variations, and a recent evidence-based clinical practice guideline from the American Academy of Orthopaedic Surgeons on the detection and management of DDH in infants 0 to 6 months of age. The purpose of this clinical report was to provide literature-based updated direction for the clinician in screening and referral for DDH, with the primary goal of preventing and/or detecting a dislocated hip by 6 to 12 months of age in an otherwise healthy child, understanding that no screening program has eliminated late development or presentation of a dislocated hip and that the diagnosis and treatment of milder forms of hip dysplasia remain controversial. Copyright © 2016 by the American Academy of Pediatrics.

  20. Framing Hip Hop: New Methodologies for New Times

    ERIC Educational Resources Information Center

    Dimitriadis, Greg

    2015-01-01

    This article revisits the central impulse behind early advocacy for ethnographic approaches to hip hop--that critics should try as much as possible to limit their own certainties around what hip hop can and might mean. While ethnographic approaches can engender the kinds of personal dislocations that allow for this negotiation, they do not…

  1. Sex and growth effect on pediatric hip injuries presenting to sports medicine clinic.

    PubMed

    Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A; Lewis, Cara L; Sugimoto, Dai

    2016-07-01

    To compare sports-related hip injuries on the basis of sex and age in a cohort of young athletes. A 5% random probability sample of all new patients' charts over a 10-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic vs. overuse), and types (bony vs. soft tissue) were compared by sex and age (preadolescent vs. adolescent). Descriptive and χ-analyses were carried out. The interaction of sex and age with respect to hip injury over time was examined by two-way (sex, age) analysis of variance. A total of 2133 charts were reviewed; N=87 hip injuries. The main diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%), and tendonitis (7.7%). The main diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%), and bursitis (4.9%). The five most common sports/activities at the time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and field (6.9%). Age by sex comparisons showed a greater proportion of the total hip injuries (38.5%) in males compared with females (8.2%) during preadolescence (5-12 years). However, in adolescence (13-17 years), the hip injury proportion was significantly higher in females (91.8%) compared with males (61.5%; P<0.001). Injury mechanism and type differed by sex, with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%) compared with males (50.0 and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progressed through puberty compared with males (analysis of variance sex-by-age interaction; P<0.001). Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age compared with males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, require further investigation to facilitate efforts aimed at prevention. Cross-sectional epidemiological study.

  2. Sex and Growth Effect on Pediatric Hip Injuries Presenting to Sports Medicine Clinic

    PubMed Central

    Stracciolini, Andrea; Yen, Yi-Meng; d'Hemecourt, Pierre A.; Lewis, Cara L.; Sugimoto, Dai

    2016-01-01

    Background To compare sports-related hip injuries based on sex and age in a cohort of young athletes. Methods 5% random probability sample of all new patients’ charts over a ten-year time period was selected for investigation. The most common hip injury diagnoses, sport at time of injury, mechanism (acute/traumatic versus overuse), and types (bony versus soft tissue) were compared by sex and age (pre-adolescent versus adolescent). Descriptive and chi-square analyzes were performed. The interaction of sex and age with regard to hip injury over time was examined by a two-way (sex, age) analysis of variance (ANOVA). Results 2,133 charts were reviewed; N=87 hip injuries. Leading diagnoses for males included labral tear (23.1%), avulsion fracture (11.5%), slipped capital femoral epiphysis (11.5%), dislocation (7.7%) and tendonitis (7.7%). Leading diagnoses for females were labral tear (59.0%), tendonitis (14.8%), snapping hip syndrome (6.6%), strain (4.9%) and bursitis (4.9%). Five most common sports/activities at time of hip injury were dancing/ballet (23.0%), soccer (18.4%), gymnastics (9.2%), ice hockey (8.1%), and track and fields (6.9%). Growth/maturation by sex showed a greater proportion of the total hip injuries (38.5%) compared to females (8.2%) during pre-adolescence (5-12 years). However, in adolescence (13-17 years), hip injury proportion was significantly greater in females (91.8%), as compared to males (61.5%; P<0.001). Injury mechanism and type differed by sex with females sustaining more chronic/overuse (95.1%) and soft tissue type injuries (93.4%), as compared to males (50.0% and 53.8%, respectively; P<0.001). Females were found to have a sharper increase in hip injury proportion as they progress through puberty as compared to males (ANOVA sex-by-age interaction; P<0.001). Conclusions Hip injury mechanism and type differed significantly between males and females during growth. Notably, the proportion of hip injuries in the young female athletes showed a significantly greater increase with advancing age as compared to males. Hip injuries in children and the interplay with growth, as it relates to injury predisposition, requires further investigation in order to facilitate efforts aimed at prevention. PMID:27058819

  3. Traumatic atlantooccipital dislocation injury in children.

    PubMed

    Nichols, J; West, J S

    1994-10-01

    The tragedy of trauma turns into triumph when the surgery team members' efforts result in victory for the patient. Nowhere is this more true than in successful pediatric trauma care. Giving a child a second chance at life and the family an opportunity for a new beginning is the highest reward for the trauma team's years of professional training and practice. Traumatic atlantoocipital dislocation injury usually results in death, but recent neurosurgery trauma advances are increasing pediatric survival rates.

  4. The breech presentation and the vertex presentation following an external version represent risk factors for neonatal hip instability.

    PubMed

    Andersson, J E; Odén, A

    2001-08-01

    The aim of this study was to evaluate the frequency and type of hip-joint instability and the frequency of hip dislocation requiring treatment in neonates who had been lying in the breech presentation and were delivered vaginally after an external version or by caesarean section, and to compare them with neonates who were naturally in the vertex presentation. Breech presentations without ongoing labour were subjected to an attempted external version and, in cases where this proved unsuccessful or where labour had started, to deliver by caesarean section. None of the breech presentations was vaginally delivered. The anterior-dynamic ultrasound method was used to assess the hip-joint status of the neonates. Out of 6,571 foetuses, 257 were in breech presentation after 36 wk of pregnancy. Sixty-two were vaginally delivered following an external version to vertex presentation and 195 were delivered by caesarean section, 75 of these following unsuccessful attempts to perform a version. Treatment for congenital hip-joint dislocation was performed on 0.2%. Out of the breech presentations, 1.0% of those delivered by caesarean section were treated, while in those with vaginal delivery following an external version the treatment frequency was 3.2%. No case of late diagnosed hip dislocation was recorded. Significant differences in frequency of hip-joint instability and treatment were found between (i) neonates delivered in breech presentation and those delivered with vertex presentation, (ii) infants delivered in vertex presentation, naturally or after successful version, and (iii) those delivered by caesarean section with or without attempted external version and those delivered with vortex presentation. Breech presentation predisposes to increased hip instability. The instability is present prior to delivery and is certainly not a primary result of delivery forces. Both breech and vertex presentations following an external or spontaneous version should be considered as risk factors for neonatal hip instability.

  5. Periacetabular Osteotomy Provides Higher Survivorship Than Rim Trimming for Acetabular Retroversion.

    PubMed

    Zurmühle, Corinne A; Anwander, Helen; Albers, Christoph E; Hanke, Markus S; Steppacher, Simon D; Siebenrock, Klaus A; Tannast, Moritz

    2017-04-01

    Acetabular retroversion can cause impaction-type femoroacetabular impingement leading to hip pain and osteoarthritis. It can be treated by anteverting periacetabular osteotomy (PAO) or acetabular rim trimming with refixation of the labrum. There is increasing evidence that acetabular retroversion is a rotational abnormality of the entire hemipelvis and not a focal overgrowth of the anterior acetabular wall, which favors an anteverting PAO. However, it is unknown if this larger procedure would be beneficial in terms of survivorship and Merle d'Aubigné scores in a midterm followup compared with rim trimming. We asked if anteverting PAO results in increased survivorship of the hip compared with rim trimming through a surgical hip dislocation in patients with symptomatic acetabular retroversion. We performed a retrospective, comparative study evaluating the midterm survivorship of two matched patient groups with symptomatic acetabular retroversion undergoing either anteverting PAO or acetabular rim trimming through a surgical hip dislocation. Acetabular retroversion was defined by a concomitantly present positive crossover, posterior wall, and ischial spine sign. A total of 279 hips underwent a surgical intervention for acetabular retroversion at our center between 1997 and 2012 (166 periacetabular osteotomies, 113 rim trimmings through surgical hip dislocation). A total of 99 patients (60%) were excluded from the PAO group and 56 patients (50%) from the rim trimming group because they had any of several prespecified conditions (eg, dysplasia or pediatric conditions 61 [37%] for the PAO group and two [2%] for the rim trimming group), matching (10 [6%]/10 [9%] hips), deficient records (10 [6%]/13 [12%] hips), or the patient declined or was lost to followup (18 [11%]/31 [27%] hips). This left 67 hips (57 patients) that underwent anteverting PAO and 57 hips (52 patients) that had acetabular rim trimming. The two groups did not differ in terms of age, sex, body mass index, preoperative ROM, preoperative Merle d'Aubigné-Postel score, radiographic morphology of the acetabulum (except total and anterior acetabular coverage), alpha angle, Tönnis grade of osteoarthritis, and labral and chondral lesions on the preoperative MRI. During the period in question, we generally performed PAO from 1997 to 2003. With the availability of surgical hip dislocation and labral refixation, we generally performed rim trimming from 2004 to 2010. With growing knowledge of the underlying pathomorphology, anteverting PAOs became more common again around 2007 to 2008. A minimum followup of 2 years was required for this study. Failures were included at any time. The median followup for the anteverting PAO group was 9.5 years (range, 2-17.4 years) and 6.8 years (range, 2.2-10.5 years) for the rim trimming group (p < 0.001). Kaplan-Meier survivorship analysis was performed using the following endpoints at 5 and 10 years: THA, radiographic progression of osteoarthritis by one Tönnis grade, and/or Merle d'Aubigné-Postel score < 15 points. Although the 5-year survivorship of the two groups was not different with the numbers available (86% [95% confidence interval {CI}, 76%-94%] for anteverting PAO versus 86% [95% CI, 76%-96%] for acetabular rim trimming), we found increased survivorship at 10 years in hips undergoing anteverting PAO for acetabular retroversion (79% [95% CI, 68%-90%]) compared with acetabular rim trimming (23% [95% CI, 6%-40%]) at 10 years (p < 0.001). The drop in the survivorship curve for the acetabular rim trimming through surgical hip dislocation group started at Year 6. The main reason for failure was a decreased Merle d'Aubigné score. Anteverting PAO may be the more appropriate treatment for hips with substantial acetabular retroversion. This may be the result of reduction of an already smaller lunate surface of hips with acetabular retroversion through rim trimming. However, rim trimming may still benefit hips with acetabular retroversion in which only one or two of the three signs are positive. Future randomized studies should compare these treatments. Level III, therapeutic study.

  6. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.

    PubMed

    Chughtai, Morad; Mistry, Jaydev B; Diedrich, Aloise M; Jauregui, Julio J; Elmallah, Randa K; Bonutti, Peter M; Harwin, Steven F; Malkani, Arthur L; Kolisek, Frank R; Mont, Michael A

    2016-10-01

    Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only. Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative-and ideally, randomized-trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols. Level IV, therapeutic study.

  7. What are the risk factors for dislocation in primary total hip arthroplasty? A multicenter case-control study of 128 unstable and 438 stable hips.

    PubMed

    Fessy, M H; Putman, S; Viste, A; Isida, R; Ramdane, N; Ferreira, A; Leglise, A; Rubens-Duval, B; Bonin, N; Bonnomet, F; Combes, A; Boisgard, S; Mainard, D; Leclercq, S; Migaud, H

    2017-09-01

    Dislocation after total hip arthroplasty (THA) is a leading reason for surgical revision. The risk factors for dislocation are controversial, particularly those related to the patient and to the surgical procedure itself. The differences in opinion on the impact of these factors stem from the fact they are often evaluated using retrospective studies or in limited patient populations. This led us to carry out a prospective case-control study on a large population to determine: 1) the risk factors for dislocation after THA, 2) the features of these dislocations, and 3) the contribution of patient-related factors and surgery-related factors. Risk factors for dislocation related to the patient and procedure can be identified using a large case-control study. A multicenter, prospective case-control study was performed between January 1 and December 31, 2013. Four patients with stable THAs were matched to each patient with a dislocated THA. This led to 566 primary THA cases being included: 128 unstable, 438 stable. The primary matching factors were sex, age, initial diagnosis, surgical approach, implantation date and type of implants (bearing size, standard or dual-mobility cup). The patients with unstable THAs were 67±12 [37-73]years old on average; there were 61 women (48%) and 67 men (52%). Hip osteoarthritis (OA) was the main reason for the THA procedure in 71% (91/128) of the unstable group. The dislocation was posterior in 84 cases and anterior in 44 cases. The dislocation occurred within 3 months of the primary surgery in 48 cases (38%), 3 to 12 months after in 23 cases (18%), 1 to 5years after in 20 cases (16%), 5 to 10years after in 17 cases (13%) and more than 10years later in 20 cases. The dislocation recurred within 6 months of the initial dislocation in 23 of the 128 cases (18%). The risk factors for instability were a high ASA score with an odds ratio (OR) of 1.93 (95% CI: 1.4-2.6), neurological disability (cognitive, motor or psychiatric disorders) with an OR of 3.9 (95% CI: 2.15-7.1), history of spinal disease (lumbar stenosis, spinal fusion, discectomy, scoliosis and injury sequelae) with an OR of 1.89 (95% CI: 1.0-3.6), unrepaired joint capsule (all approaches) with an OR of 4.1 (95% CI: 2.3-7.37), unrepaired joint capsule (posterior approach) with an OR of 6.0 (95% CI: 2.2-15.9), and cup inclination outside Lewinnek's safe zone (30°-50°) with OR of 2.4 (95% CI: 1.4-4.0). This large comparative study isolated important patient-related factors for dislocation that surgeons must be aware of. We also found evidence that implanting the cup in 30° to 50° inclination has a major impact on preventing dislocation. Level III; case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. OrthoIllustrated Web Based Orthopaedic Sports Medicine Registry

    ClinicalTrials.gov

    2018-04-06

    Degenerative and Traumatic Pathology of the Knee; Degenerative and Traumatic Pathology of the Shoulder and Elbow; Degenerative and Traumatic Pathology of the Foot and Ankle; Degenerative and Traumatic Pathology of the Hand and Wrist; Degenerative and Traumatic Pathology of the Hip

  9. Stability of the Giliberty bipolar hip: report of three cases.

    PubMed

    Langan, P; Weiss, C A

    1978-01-01

    The Giliberty Bipolar Hip Prosthesis consists of an unbonded acetabular cup which snap-fits over the head of the femoral prosthesis. Because of the free movement permitted at the cup-pelvic junction as well as at the snap-fit interface, there has been a great deal of concern over the potential for dislocation. Three patients in whom this unit was implanted sustained significant skeletal trauma subsequent to surgery. None of them dislocated. In each case the prosthetic head was known to be in a relatively vertical orientation with respect to the transverse axis of the pelvis prior to the injury. In 2 of the 3 cases radiographically identifiable movement of the cup was present before and after the injury. These observations suggest that the persistently mobile, vertically positioned unbonded cup remain stable despite the stress of significant trauma. It is probable that the potential for cup movement, even where on the X-ray it appears to have stopped, acts as a safety valve in absorbing force that might otherwise dislocate the hip or cause fractures of the femur or the pelvis.

  10. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    PubMed

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  11. Endovascular Repair of a Traumatic Axillary Pseudoaneurysm Following Anterior Shoulder Dislocation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stahnke, Michaela; Duddy, Martin J.

    2006-04-15

    Pseudoaneurysms due to musculoskeletal trauma are rare and comprise less than 2% of all pseudoaneurysms. We report a case of axillary pseudoaneurysm following anterior dislocation of the shoulder. The patient was successfully treated by endovascular intervention.

  12. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  13. Hip Surveillance in Children with Cerebral Palsy.

    PubMed

    Huser, Aaron; Mo, Michelle; Hosseinzadeh, Pooya

    2018-04-01

    The hip is the second most common involved joint in cerebral palsy. Hip displacement occurs in more than 33% of children with cerebral palsy, with a higher prevalence in nonambulatory children. Hip displacement in this population is typically progressive. Hip dislocation can result in pain and difficulty with sitting and perineal care. Since early stage of hip displacement can be silent, and hip surveillance programs are recommended. Most programs use the degree of hip dysplasia and Growth Motor Function Classification System level for screening recommendations. Treatment depends on the degree of dysplasia, functional status of the patient, and patient's age. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis

    PubMed Central

    Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu

    2018-01-01

    Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733

  15. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    PubMed

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk of dislocation or a chronically unstable hip prosthesis. Careful technique is required to reduce or retard the risk of intra-prosthetic dislocation. Intra-prosthetic dislocation of a dual mobility socket is an exceptional complication at mid-term. Surgical treatment is required but may be limited to simple insert replacement. Systematic use of this type of implant in young subjects must be carefully examined, but for us, the risk of dislocation does not outweigh the advantages of this original concept of dual mobility. This type of socket remains an useful preventive technique for high-risk hips or for curative treatment of recurrent dislocation.

  16. Early results of one-stage correction for hip instability in cerebral palsy.

    PubMed

    Kim, Hui Taek; Jang, Jae Hoon; Ahn, Jae Min; Lee, Jong Seo; Kang, Dong Joon

    2012-06-01

    We evaluated the clinical and radiological results of one-stage correction for cerebral palsy patients. We reviewed clinical outcomes and radiologic indices of 32 dysplastic hips in 23 children with cerebral palsy (13 males, 10 females; mean age, 8.6 years). Ten hips had dislocation, while 22 had subluxation. Preoperative Gross Motor Function Classification System (GMFCS) scores of the patients were as follows; level V (13 patients), level IV (9), and level III (1). Acetabular deficiency was anterior in 5 hips, superolateral in 7, posterior in 11 and mixed in 9, according to 3 dimensional computed tomography. The combined surgery included open reduction of the femoral head, release of contracted muscles, femoral shortening varus derotation osteotomy and the modified Dega osteotomy. Hip range of motion, GMFCS level, acetabular index, center-edge angle and migration percentage were measured before and after surgery. The mean follow-up period was 28.1 months. Hip abduction (median, 40°), sitting comfort and GMFCS level were improved after surgery, and pain was decreased. There were two cases of femoral head avascular necrosis, but no infection, nonunion, resubluxation or redislocation. All radiologic indices showed improvement after surgery. A single event multilevel surgery including soft tissue, pelvic and femoral side correction is effective in treating spastic dislocation of the hip in cerebral palsy.

  17. Shoulder Problems in Athletes.

    ERIC Educational Resources Information Center

    Clancy, William G., Jr.

    A description is given of typical sport-related injuries to the shoulder area. These include: (1) brachial plexus injuries; (2) peripheral nerve injuries about the shoulder; (3) acromioclavicular injuries; (4) sternoclavicular injuries; (5) shoulder dislocations; (6) recurrent traumatic subluxation/dislocations; and (7) overuse injuries.…

  18. Exposure of the sciatic nerve in the gluteal region without sectioning the gluteus maximus: Analysis of a series of 18 cases

    PubMed Central

    Socolovsky, Mariano; Masi, Gilda Di

    2012-01-01

    Background: Dissecting through the gluteus maximus muscle by splitting its fibers, instead of complete sectioning of the muscle, is faster, involves less damage to tissues, and diminishes recovery time. The objective of the current paper is to present a clinical series of sciatic nerve lesions where the nerve was sufficiently exposed via the transgluteal approach. Methods: We retrospectively selected 18 traumatic sciatic nerve lesions within the buttock, operated upon from January 2005 to December 2009, with a minimum follow-up of 2 years. In all patients, a transgluteal approach was employed to explore and reconstruct the nerve. Results: Ten males and eight females, with a mean age of 39.7 years, were studied. The etiology of the nerve lesion was previous hip surgery (n = 7), stab wound (n = 4), gunshot wound (n = 3), injection (n = 3), and hip dislocation (n = 1). In 15 (83.3%) cases, a motor deficit was present; in 12 (66.6%) cases neuropathic pain and in 12 (66.6%) cases sensory alterations were present. In all cases, the transgluteal approach was adequate to expose the injury and treat it by neurolysis alone (10 cases), neurolysis and neurorrhaphy (4 cases), and reconstruction with grafts (4 cases; three of these paired with neurolysis). The mean pre- and postoperative grades for the tibial nerve (LSUHSC scale) were 1.6 and 3.6, respectively; meanwhile, for the peroneal division, preoperative grade was 1.2 and postoperative grade was 2.4. Conclusions: The transgluteal approach adequately exposes sciatic nerve injuries of traumatic origin in the buttock and allows for adequate nerve reconstruction without sectioning the gluteus maximus muscle. PMID:22439106

  19. [New classification of Crowe type IV developmental dysplasia of the hip].

    PubMed

    Ma, Hai-yang; Zhou, Yong-gang; Zheng, Chong; Cao, Wen-zhe; Wang Sen; Wu, Wen-ming; Piao, Shang; Du, Yin-qiao

    2016-02-01

    To compare differences between Crowe IV developmental dysplasia of the hip (DDH) with secondary acetabulum and Crowe IV DDH without secondary acetabulum,and determine whether it is necessary to divide Crowe IV DDH into two subtypes. From June 2007 to May 2015,145 hips of 112 Crowe N patients who underwent total hip arthroplasty (THA) using S-ROM stem were divided into two groups: secondary acetabulum formaton group (group A) and no secondary acetabulum formaton group (group B). In group A,there were 12 females, 96 males,with an average age of (39.38 ± 11.19) years old. In group B, there were 2 females, 35 males, with an average age of (38.19 ± 10.92) years old. All the patients were evaluated by using Harris Hip Score. Radiographic evaluations were made preoperatively and during follow up. The differences between two groups were compared on dislocation height, canal flare index (CFI), subtrochanteric shortening osteotomy (SSTO) usage, pre- and post-operation Harris scores, complications. The dislocation height for group A was (4.74 ± 1.57) cm, while the dislocation height for group B was (3.12 ± 1.15) cm. Significantly difference was detected between two groups. The CFI for group A was 2.69 ± 0.68, while the CFI for group B was 3.42 ± 0.79, and the significantly difference was detected between two groups. Harris scores were totally improved from 58.18 ± 15.67 preoperatively to 91.20 ± 3.79 post-operatively and the difference was significant. Pre-operative Harris scores was 58.1 ± 15.3 in group A, 58.3 ± 16.9 in group B. Post-operative Harris scores was 91.0 ± 4.1 in group A, 91.0 ± 5.1 in group B. No significant difference was found on Harris scores between A and B preoperatively and post-operatively. Complications of 4 cases peri-prosthesis fracture, 4 cases dislocation and 4 cases nerve injury occur in group A; While only one case dislocation and one case nerve injury occur in group B. No statistical significance was detected. Crowe IV DDH with secondary acetabulum is significantly different from Crowe IV DDH without secondary acetabulum on dislocation height and femoral morphology, which causes the different selections of surgical techniques (SSTO usage or not). These important differences in fundamental parameters indicate the necessity to further divide Crowe IV DDH into IVA and IVB two subtypes.

  20. Late-onset traumatic dislocation of laser in situ keratomileusis corneal flaps: a case series with many clinical lessons.

    PubMed

    Ting, Darren Shu Jeng; Danjoux, Jean-Pierre

    2018-05-12

    To report three cases of late-onset (7-14 years postoperative) traumatic dislocation of laser in situ keratomileusis (LASIK) flaps with epithelial ingrowth that all had delayed surgical intervention. A retrospective, interventional case series of three patients who underwent flap repositioning and mechanical debridement of epithelial ingrowth, all after an initial delayed diagnosis/treatment of dislocated LASIK flap. Visual improvement was noted in all three cases following LASIK flap repositioning and debridement of epithelial ingrowth; patient 1 improved from 20/800 corrected-distance-visual-acuity (CDVA) to 20/20 uncorrected-distance-visual-acuity (UDVA) postoperative (14 years post-LASIK, 5-week interval between injury and surgery), patient 2 improved from 20/50 CDVA to 20/20 CDVA (10 years post-LASIK, 4-month interval between injury and surgery) and patient 3 improved from 20/80 CDVA to 20/60 CDVA (7 years post-LASIK, 14-month interval between injury and surgery). Flap dislocation was not suspected or diagnosed in two patients during the first ophthalmic visit. Postoperative visual outcome was not influenced by the presenting vision but might be negatively affected by the delay in surgical intervention, the presence of preoperative central epithelial ingrowth and postoperative striae. This case series reported one of the longest documented intervals between LASIK and traumatic dislocation of LASIK flap with secondary epithelial ingrowth. Delayed diagnosis and management of flap dislocation after corneal trauma may potentially increase the risk of epithelial ingrowth, recalcitrant flap striae and visual impairment. The presence of late-onset epithelial ingrowth in patients with previous LASIK mandates careful examination for occult flap displacement.

  1. Radiology of adolescent slipped capital femoral epiphysis: measurement of epiphyseal angles and diagnosis.

    PubMed

    Gekeler, Jörg

    2007-10-01

    AIMS OF DIAGNOSTIC RADIOGRAPHY: Visualization of the proximal femur in two clearly defined projections. Radiologic and morphological diagnosis of slipped capital femoral epiphysis. Evaluation of the stability of the femoral epiphysis: chronic slippage or acute interruption of continuity between the femoral epiphysis and the femoral neck metaphysis. Radiometric measurement of the spatial deformity of the femoral epiphysis. Measurement of the projected epiphyseal angle on the radiograph as the basis for possible conversion into anatomically correct angles at the proximal femur. Preoperative planning of therapeutic surgical procedures. Idiopathic hip pain in the growing child or adolescent. Referred pain to the knee or thigh. Unusual gait pattern with external rotation deformity of the leg, limping that favors one leg or limping due to leg length discrepancy. Abnormal sonography, CT or MRI findings. Eventful history including minor injury or genuine trauma. Symptoms and uncommon physical constitution: obesity, exceptional longitudinal growth of the extremities, and absence of secondary sex characteristics. Indications for Radiographic Imaging of the Hip Joint in Two Planes None. Standard positioning of the patient or the affected extremity. First standard radiograph: proximal femur in anteroposterior projection. Position of the leg with the patella directed anteriorly. Contraction of the external rotators at the hip joint is compensated by elevation of the hip until the leg is in the neutral position. Second standard radiograph: axial view of the proximal femur in anteroposterior projection. Leg flexed to 90 degrees at the hip and in 45 degrees abduction. Thigh position parallel to the longitudinal axis of the table (zero rotation). Early signs of incipient or imminent femoral epiphyseolysis: --Disintegration, widening and blurred margins of the epiphyseal plate. --Increasing loss of height of the femoral epiphysis due to incipient dislocation. --The tangent to the lateral femoral neck intersects only slightly with the femoral head or runs tangential to the epiphysis. --Important second radiograph in axial projection: incipient slippage is seen early here. Comparison with the contralateral side. Chronic slipped capital femoral epiphysis in adolescents: --Advanced epiphyseal dislocation visible in both planes. The tangent to the lateral femoral neck no longer intersects with the dislocated femoral epiphysis. In some cases, varus deformity of the femoral neck and periosteal elevation at the borders of the medial femoral neck. --Epiphyseal dislocation even more apparent in the axial view. Acute slipped capital femoral epiphysis in adolescents: --Complete interruption of continuity between epiphysis and metaphysis. --Widened gap between epiphysis and metaphysis. --Cystic irregularities of the metaphysis. --In most cases, substantial dislocation between epiphysis and metaphysis. --"Acute on chronic slip": specific type of acute epiphyseal dislocation subsequent to chronic epiphyseolysis. In addition to signs of acute separation, secondary symptoms of chronic epiphyseolysis such as femoral neck arcuation and spur formation at the head-neck junction. --Dynamic fluoroscopy may be indicated to confirm acute dislocation. Defined axes are marked on the radiograph: anatomic axis of the femur, femoral neck axis, and so-called epiphyseal axis (perpendicular to the base of the epiphysis). Measurement of the projected epiphysis-diaphysis angle (ED' angle) on the anteroposterior radiograph and the projected epiphyseal torsion angle (ET' angle) on the axial radiograph. For slight to moderate slippage, the difference between the epiphyseal dislocation angle obtained from the radiographs (as projected in two planes) compared with the anatomic, i.e., real dislocation angle at the proximal femur is generally relatively minor. Conversion of the projected angle to the real angle is not essential in these cases (if in doubt, see Table 1). For more severe dislocations, the differences between the projected and real angles are far more apparent. Table 1 facilitates conversion of the epiphyseal dislocation angles taken from the radiograph into anatomically correct dislocation angles at the proximal femur. Conversion to real angles, especially for preoperative planning of complex corrective surgery, is indicated for more severe deformities of the femoral epiphysis. Conversion into real (anatomic) angles is indicated for exact prognostic evaluation of prearthrotic deformities.

  2. Radiographic comparison of surgical hip dislocation and hip arthroscopy for treatment of cam deformity in femoroacetabular impingement.

    PubMed

    Bedi, Asheesh; Zaltz, Ira; De La Torre, Katrina; Kelly, Bryan T

    2011-07-01

    Whether open or arthroscopic techniques are employed, the goal of femoroacetabular impingement (FAI) surgery is to achieve impingement-free range of motion. While arthroscopic approaches have improved and gained popularity, an objective evaluation of the surgical correction achieved with this approach compared with open surgery remains to be defined in the literature. This study was undertaken to compare the efficacy of arthroscopic osteoplasty and open surgical dislocation in treating FAI dysmorphology in a consecutive series of patients. Cohort study; Level of evidence, 3. Surgical treatment was performed in 60 male patients under 40 years of age for symptomatic FAI refractory to nonoperative management. Patients were matched (not randomized) to treatment groups: 30 patients (15 left and 15 right hips) underwent arthroscopic cam and/or rim osteoplasty with labral debridement and/or refixation by an arthroscopic surgeon; and 30 (14 left and 16 right hips) underwent open surgical dislocation, cam and/or rim osteoplasty, and labral debridement or refixation by a hip preservation surgeon. Anteroposterior (AP) pelvis and extended-neck (Dunn) lateral radiographs were obtained and the depth of resection and arc of resection were measured by assessment of anterior femoral head-neck offset, AP and lateral α angle, and β angle on preoperative and postoperative radiographs. In the arthroscopic group, the extended-neck lateral α angle was reduced by a mean of 17.2° (28.3%, P < .05), AP α angle was reduced by a mean of 12.6° (16.8%), anterior head-neck offset improved 5.0 mm (111%, P < .05), and β angle increased by a mean of 23.1°. In the open dislocation group, the extended-neck lateral α angle was reduced by a mean of 21.2° (30.7%, P < .05), AP α angle was reduced by a mean of 20.1° (25.7%), anterior head-neck offset improved 6.56 mm (108%, P < .05), and β angle increased by a mean of 18.35°. Arthroscopic osteoplasty can restore head-neck offset and achieve similar depth, arc, and proximal-distal resection with comparable efficacy to open surgical dislocation for anterior and anterosuperior cam and focal rim impingement deformity. The open technique, however, may allow greater correction of posterosuperior loss of femoral offset and may be favorable for FAI patterns that demonstrate considerable proximal femoral deformity on AP radiographs.

  3. Controversies in the Management of the First Time Shoulder Dislocation

    PubMed Central

    Avila Lafuente, José Luis; Moros Marco, Santos; García Pequerul, José Manuel

    2017-01-01

    Background: Traditionally, initial management of first anterior shoulder dislocations consists of reduction of the glenohumeral joint followed by a period of immobilization and subsequent physical therapy to recover shoulder range of motion and strength. This traditional approach in management is now controversial due to the high rate of recurrence. The aim of this paper is to review and discuss the literature about the global management of patients presenting with first-time traumatic anterior glenohumeral dislocation, analyzing the factors that affect shoulder instability after the first episode of dislocation. Methods: Scientific publications about the management of first-time shoulder dislocations are reviewed. Pubmed is used for that and no limit in the year of publication are stablished. These papers and their conclusions are discussed. Results: Younger patients, patient´s activities and the kind of injury are the most important factors related to the shoulder instability after a first time traumatic dislocation. Authors that recommend surgical treatment after the first episode of dislocation argue that the possibilities of recurrence are high and therefore surgery should be performed before its occurrence. Other authors, however, argue that surgical treatment is demanding, and keep in mind that complications, such as recurrence, stiffness and pain after surgery, are still present. Conclusion: Currently, there is still no consensus in the literature with regard to the management of first episode of shoulder dislocation. It is necessary to analyze carefully every individual case to manage them more or less aggressive to obtain the best result in our practice. PMID:29430264

  4. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

    PubMed

    Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H

    2017-03-01

    To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.

  5. [New varieties of lateral metatarsophalangeal dislocations of the great toe].

    PubMed

    Bousselmame, N; Rachid, K; Lazrak, K; Galuia, F; Taobane, H; Moulay, I

    2001-04-01

    We report seven cases of traumatic dislocation of the great toe, detailing the anatomy, the mechanism of injury and the radiographic diagnosis. We propose an additional classification based on three hereto unreported cases. Between october 1994 and october 1997, we treated seven patients with traumatic dislocation of the first metatarso-phalangeal joint of the great toe. There were six men and one woman, mean age 35 years (range 24 - 44 years). Dislocation was caused by motor vehicle accidents in four cases and by falls in three. Diagnosis was made on anteroposterior, lateral and medial oblique radiographs. According to Jahss' classification, there was one type I and three type IIB dislocations. There was also one open lateral dislocation and two dorsomedial dislocations. Only these dorsomedial dislocations required open reduction, done via a dorsal approach. Mean follow-up was 17.5 months (range 9 - 24 months) in six cases. One patient was lost to follow-up. The outcome was good in six cases and poor in one (dorsomedial dislocation). Dislocation of the first metatarso-phalangeal joint of the great toe is an uncommon injury. In 1980, Jahss reported two cases and reviewed three others described in the literature. He proposed three types of dislocation based on the feasibility of closed reduction (type I, II and IIB). In 1991, Copeland and Kanat reported a unique case in which there was an association of IIA and IIB lesions. They proposed an addition to the classification (type IIC). In 1994, Garcia Mata et al. reported another case which had not been described by Jahss and proposed another addition. All dislocations reported to date have been sagittal dislocations. Pathological alteration of the collateral ligaments has not been previously reported. In our experience, we have seen one case of open lateral dislocation due, at surgical exploration, to medial ligament rupture and two cases of dorsomedial dislocation due, at surgical exploration, to lateral ligament rupture. We propose another additional classification with pure lateral dislocation (type III) and dorso-lateral dislocation (type IL or IIL+), which are related to the formerly described variants.

  6. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    PubMed

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides better covering of the cup with solid bone, without the necessity of cotyloplasty or structural graft use. Also, it does not markedly affect hip function or patients' subjective feelings.

  7. A new surgical technique for traumatic dislocation of posterior tibial tendon with avulsion fracture of medial malleolus.

    PubMed

    Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol

    2015-01-01

    We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.

  8. [Analysis of the failures of a cemented constrained liner model in patients with a high dislocation risk].

    PubMed

    Gallart, X; Gomez, J C; Fernández-Valencia, J A; Combalía, A; Bori, G; García, S; Rios, J; Riba, J

    2014-01-01

    To evaluate the short-term results of an ultra high molecular weight polyethylene retentive cup in patients at high risk of dislocation, either primary or revision surgery. Retrospective review of 38 cases in order to determine the rate of survival and failure analysis of a constrained cemented cup, with a mean follow-up of 27 months. We studied demographic data, complications, especially re-dislocations of the prosthesis and, also the likely causes of system failure analyzed. In 21.05% (8 cases) were primary surgery and 78.95% were revision surgery (30 cases). The overall survival rate by Kaplan-Meier method was 70.7 months. During follow-up 3 patients died due to causes unrelated to surgery and 2 infections occurred. 12 hips had at least two previous surgeries done. It wasn't any case of aseptic loosening. Four patients presented dislocation, all with a 22 mm head (P=.008). Our statistical analysis didn't found relationship between the abduction cup angle and implant failure (P=.22). The ultra high molecular weight polyethylene retentive cup evaluated in this series has provided satisfactory short-term results in hip arthroplasty patients at high risk of dislocation. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  9. Open and Arthroscopic Surgical Treatment of Femoroacetabular Impingement

    PubMed Central

    Kuhns, Benjamin D.; Frank, Rachel M.; Pulido, Luis

    2015-01-01

    Femoroacetabular impingement (FAI) is a common cause of hip pain, and when indicated, can be successfully managed through open surgery or hip arthroscopy. The goal of this review is to describe the different approaches to the surgical treatment of FAI. We present the indications, surgical technique, rehabilitation, and complications associated with (1) open hip dislocation, (2) reverse periacetabular osteotomy, (3) the direct anterior “mini-open” approach, and (4) arthroscopic surgery for FAI. PMID:26697431

  10. Conversion of hip fusion to total hip arthroplasty: clinical, radiological outcomes and complications in 40 hips.

    PubMed

    Celiktas, Mustafa; Kose, Ozkan; Turan, Adil; Guler, Ferhat; Ors, Cagri; Togrul, Emre

    2017-01-01

    The purpose of this retrospective study is to report the clinical and radiological outcome of total hip arthroplasty in patients with previous hip arthrodesis. We retrospectively reviewed 28 (40 hips) prospectively followed patients in whom ankylosed hips were converted to total hip arthroplasty (THA) between 2010 and 2014 in our institution. The average age at the time of the conversion operation was 40.8 ± 9.8 years (range 24-62). The ankylosis had lasted 20.4 ± 13.0 years (range 3-56) before conversion surgery. The etiology of the ankylosis was septic arthritis in 10 (25%), post-traumatic hip osteoarthritis in 8 (20%), developmental hip dysplasia in 6 (15%), rheumatoid arthritis in 6 (15%), primary osteoarthritis in 5 (12.5%) and ankylosing spondylitis in 5 (12.5%) hips. The indications for arthroplasty were intractable low back pain in 14 (50%), hip pain in 24 (85.7%), and ipsilateral knee pain in 19 (67.8%) patients. Harris Hip Score (HHS) was used to rate the clinical results before and after the surgery. Radiographic evaluations included component malposition and loosening. All complications during the study period were recorded. The mean follow-up period was 39.9 ± 10.6 months (range 24-60). The mean preoperative HHS was 33.3 ± 8.6 (range 18-50) and the mean HHS at the final follow-up was 74.9 ± 8.6 (range 52-97). There was a statistically significant increase in HHS (p = 0.0001). HHS was excellent in 1, good in 6, fair in 14 and poor in 7 patients. Increase in HHS was lower than 20 points in one patient (18 points), and one patient required two-staged exchange procedure due to deep infection. Thus, according to our success criteria (increase in HHS more than 20 points, radiographically stable implant, and no further surgical reconstruction), 92.8% (26/28) of patients had benefit from the surgery. Trendelenburg sign was positive in 12 hips. There was limb length inequality in 11 patients (mean 0.5 cm, range 1-3 cm). No patients had heterotopic ossification, sciatic nerve palsy or dislocation. There were five intra-operative fractures of the greater trochanter that were treated with cable wiring. One patient had trochanteric avulsion injury and was treated with trochanteric grip and cables. One patient (2.5%) had deep infection one year after the conversion THA and was treated with two-staged exchange procedure. Conversion hip arthroplasty is an effective treatment method which provides functional recovery and patient satisfaction. However, a proper surgical technique and planning is necessary to minimize the complications.

  11. A neuromuscular exercise programme versus standard care for patients with traumatic anterior shoulder instability: study protocol for a randomised controlled trial (the SINEX study).

    PubMed

    Eshoj, Henrik; Rasmussen, Sten; Frich, Lars Henrik; Hvass, Inge; Christensen, Robin; Jensen, Steen Lund; Søndergaard, Jens; Søgaard, Karen; Juul-Kristensen, Birgit

    2017-02-28

    Anterior shoulder dislocation is a common injury and may have considerable impact on shoulder-related quality of life (QoL). If not warranted for initial stabilising surgery, patients are mostly left with little to no post-traumatic rehabilitation. This may be due to lack of evidence-based exercise programmes. In similar, high-impact injuries (e.g. anterior cruciate ligament tears in the knee) neuromuscular exercise has shown large success in improving physical function and QoL. Thus, the objective of this trial is to compare a nonoperative neuromuscular exercise shoulder programme with standard care in patients with traumatic anterior shoulder dislocations (TASD). Randomised, assessor-blinded, controlled, multicentre trial. Eighty patients with a TASD will be recruited from three orthopaedic departments in Denmark. Patients with primary or recurrent anterior shoulder dislocations due to at least one traumatic event will be randomised to 12 weeks of either a standardised, individualised or physiotherapist-supervised neuromuscular shoulder exercise programme or standard care (self-managed shoulder exercise programme). Patients will be stratified according to injury status (primary or recurrent). Primary outcome will be change from baseline to 12 weeks in the patient-reported QoL outcome questionnaire, the Western Ontario Shoulder Instability Index (WOSI). This trial will be the first study to compare the efficacy and safety of two different nonoperative exercise treatment strategies for patients with TASD. Moreover, this is also the first study to investigate nonoperative treatment effects in patients with recurrent shoulder dislocations. Lastly, this study will add knowledge to the shared decision-making process of treatment strategies for clinical practice. ClinicalTrials.gov, identifier: NCT02371928 . Registered on 9 February 2015 at the National Institutes of Health Clinical Trials Protocol Registration System.

  12. A Rare Case of Massive Rotator Cuff Tear and Biceps Tendon Rupture with Posterior Shoulder Dislocation in a Young Adult - Surgical Decision-making and Outcome

    PubMed Central

    Soon, En Loong; Razak, Hamid Rahmatullah Bin Abd; Tan, Andrew Hwee Chye

    2017-01-01

    Introduction: Massive rotator cuff tears (RCTs) in the context of shoulder dislocations are relatively uncommon in the young adult (<40 years) and if reported are more commonly described in association with acute traumatic anterior glenohumeral dislocations. They have rarely been described with posterior dislocations, regardless of patient age. This is the 1st case reported in the context of posterior dislocations, where a triad of biceps tendon rupture, posterior dislocation, and RCTs was observed during surgery. It provides an important reminder to readers about certain injuries commonly overlooked during the assessment of an acute traumatic shoulder. Case Report: We report an atypical case of a massive RCT involving a 34-year-old Asian male who landed on his outstretched hand after falling off a bicycle. A tear involving the supraspinatus and subscapularis was visualized during surgery, along with long head of biceps (LHB) tendon rupture. This was after an initial failure to achieve closed reduction of the posteriorly dislocated left shoulder. Conclusion: It is easy to miss the posterior instability, the associated RCTs or the biceps tendon injuries. Biceps tendon rupture should be a consideration when one is unable to reduce a posteriorly dislocated shoulder. The interposed torn LHB tendon trapped within the glenohumeral joint was the likely physical block in the initial failure to achieve closed reduction. With timely diagnosis, prudent physical examination, early imaging and surgery, and excellent results can potentially be achieved to return a young patient to full functionality. PMID:28819610

  13. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    PubMed

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. The effect of soft tissue release of the hips on walking in myelomeningocele.

    PubMed

    Correll, J; Gabler, C

    2000-06-01

    Walking and standing capacity in myelomeningocele is highly dependent on the level of the neurological lesion. Deformities, mainly flexion deformities, of the hip can severely interfere with mobility. In a retrospective study, undertaken in our hospital, we evaluated the role of soft tissue release of the hip in patients with hip flexion contractures. A special surgical technique was performed in 55 hips. The results show a good effect on verticalization, even if the hip joints cannot be extended actively. A subluxated or dislocated hip did not influence the final outcome. During the mean follow-up of approximately 4 years, only a slight recurrence of the former deformity was observed. Most of the patients obtained great advantage from the operation.

  15. The minimal invasive direct anterior approach in combination with large heads in total hip arthroplasty - is dislocation still a major issue? a case control study.

    PubMed

    Hoell, Steffen; Sander, Marius; Gosheger, Georg; Ahrens, Helmut; Dieckmann, Ralf; Hauschild, Gregor

    2014-03-12

    There have been increasing numbers of publications in recent years on minimally invasive surgery (MIS) for total hip arthroplasty (THA), reporting results with the use of different head sizes, tribologic and functional outcomes. This study presents the results and early complication rates after THA using the direct anterior approach (DAA) in combination with head sizes ≥ 36 mm. A total of 113 patients with THA were included in the study. The Harris Hip Score (HHS) was determined, a radiographic evaluation was carried out, and complications were recorded. The minimum follow-up period was 2 years (means 35 ± 7 months). The HHS improved from 43.6 (± 12) to 88.2 (± 14; P < 0.01). One early infection occurred, one periprosthetic fracture, and three cases of aseptic stem loosening. No incorrect positioning of the implants was observed, and there were no dislocations. THA with the minimally invasive DAA in combination with large heads is associated with good to very good functional results in the majority of cases. The complication rates are not increased. The rate of dislocation mainly as an complication of the first two years can be markedly reduced in particular.

  16. Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

    PubMed

    Assi, Chahine; El-Najjar, Elie; Samaha, Camille; Yammine, Kaissar

    2017-03-01

    Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.

  17. Developmental dysplasia of the hip: addressing evidence gaps with a multicentre prospective international study.

    PubMed

    Schaeffer, Emily K; Study Group, Ihdi; Mulpuri, Kishore

    2018-05-07

    There is a lack of high quality evidence available to guide clinical practice in the treatment and management of developmental dysplasia of the hip (DDH). Evidence has been limited by persistent confusion on diagnostic and classification terminology, variability in surgeon decision making and a reliance on single centre, retrospective studies with small patient numbers. To address gaps in knowledge regarding screening, diagnosis and management of DDH, the International Hip Dysplasia Institute began a multicentre, international prospective study on infants with hips dislocated at rest. This review discusses the current state of screening, diagnostic and management practices in DDH and addresses important unanswered questions that will be critical in identifying best practices and optimising patient outcomes. There is insufficient evidence to support universal ultrasound screening; instead, selective screening should be performed by 6-8 weeks of age on infants with risk factors of breech presentation, family history, or history of clinical hip instability. Follow-up of infants with risk factors and normal initial screening should be considered to at least 6 months of age. Brace treatment is a sensible first-line treatment for management of dislocated hips at rest in infants < 6 months of age. Early operative reduction may be considered as there is insufficient evidence to support a protective role for the ossific nucleus in the development of avascular necrosis.

  18. Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model

    PubMed Central

    Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D

    2004-01-01

    Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198

  19. 1997 Accession Medical Standards Analysis & Research Activity (AMSARA) Annual Report

    DTIC Science & Technology

    1998-05-01

    3.7 Hip Dental 13 2.8 Hip dislocation 44 2.1 Injury-lower 11 2.4 Foot-ankle 41 1.9 extremities Prior knee surgery .7 1.5 Curvature of the spine 35...Genetic Influences in Childhood-Onset Psychiatric Disorders: Autism and Attention-Deficit/Hyperactivity Disorder. Am J Hum Genet 1997;60:1276-1282

  20. Sexual activity after total hip replacement in Korean patients: how they do, what they want, and how to improve.

    PubMed

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2013-12-01

    Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.

  1. Sexual Activity after Total Hip Replacement in Korean Patients: How They Do, What They Want, and How to Improve

    PubMed Central

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi

    2013-01-01

    Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146

  2. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    PubMed Central

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. CONCLUSION To take early treatment of traumatic lens subluxation/dislocation in patients with secondary glaucoma by individual surgical plan based on the different eye conditions would be safe and effective, which can effectively control the intraocular pressure and restore some vision. PMID:24790868

  3. Anterior cervical distraction and screw elevating–pulling reduction for traumatic cervical spine fractures and dislocations

    PubMed Central

    Li, Haoxi; Yong, Zhiyao; Chen, Zhaoxiong; Huang, Yufeng; Lin, Zhoudan; Wu, Desheng

    2017-01-01

    Abstract Treatment of cervical fracture and dislocation by improving the anterior cervical technique. Anterior cervical approach has been extensively used in treating cervical spine fractures and dislocations. However, when this approach is used in the treatment of locked facet joints, an unsatisfactory intraoperative reduction and prying reduction increases the risk of secondary spinal cord injury. Thus, herein, the cervical anterior approach was improved. With distractor and screw elevation therapy during surgery, the restoration rate is increased, and secondary injury to the spinal cord is avoided. To discuss the feasibility of the surgical method of treating traumatic cervical spine fractures and dislocations and the clinical application. This retrospective study included the duration of patients’ hospitalization from January 2005 to June 2015. The potential risks of surgery (including death and other surgical complications) were explained clearly, and written consents were obtained from all patients before surgery. The study was conducted on 86 patients (54 males and 32 females, average age of 40.1 ± 5.6 years) with traumatic cervical spine fractures and dislocations, who underwent one-stage anterior approach treatment. The effective methods were evaluated by postoperative follow-up. The healing of the surgical incision was monitored in 86 patients. The follow-up duration was 18 to 36 (average 26.4 ± 7.1) months. The patients achieved bones grafted fusion and restored spine stability in 3 to 9 (average 6) months after the surgery. Statistically, significant improvement was observed by Frankel score, visual analog scale score, Japanese Orthopedic Association score, and correction rate of the cervical spine dislocation pre- and postoperative (P < .01). The modified anterior cervical approach is simple with a low risk but a good effect in reduction. In addition, it can reduce the risk of iatrogenic secondary spinal cord injury and maintain optimal cervical spine stability as observed during follow-ups. Therefore, it is suitable for clinical promotion and application. PMID:28658125

  4. Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability

    PubMed Central

    Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Béjui-Hugues, Jacques

    2008-01-01

    Unconstrained tripolar hip implants provide an additional bearing using a mobile polyethylene component between the prosthetic head and the outer metal shell. Such a design increases the effective head diameter and therefore is an attractive option in challenging situations of unstable total hip arthroplasties. We report our experience with 54 patients treated using this dual mobility implant in such situations. We ascertained its ability to restore and maintain stability, and examined component loosening and component failure. At a minimum followup of 2.2 years (mean, 4 years; range, 2.2–6.8 years), one hip had redislocated 2 months postoperatively and was managed successfully without reoperation by closed reduction with no additional dislocation. Two patients required revision of the implant because of dislocation at the inner bearing. Technical errors were responsible for these failures. Three patients had reoperations for deep infections. The postoperative radiographs at latest followup showed very satisfactory osseointegration of the acetabular component because no radiolucent line or osteolysis was reported. Use of this unconstrained tripolar design was successful in restoring and maintaining hip stability. We observed encouraging results at short-term followup regarding potential for loosening or mechanical failures. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18780135

  5. Anterior total hip arthroplasty using a metaphyseal bone-sparing stem: component alignment and early complications.

    PubMed

    Ahmed, Mohammed M; Otto, Thomas J; Moed, Berton R

    2016-04-22

    Limited-incision total hip arthroplasty (THA) preserves hip abductors, posterior capsule, and external rotators potentially diminishing dislocation risk. However, potential complications also exist, such as component malposition. Specific implants have been manufactured that enhance compatibility with this technique, while preserving metaphyseal bone; however, little data exists documenting early complications and component position. The purpose was to evaluate primary THA using a curved, bone-sparing stem inserted through the anterior approach with respect to component alignment and early complications. In a retrospective analysis of 108 cases, the surgical technique was outlined and the occurrence of intraoperative fractures, postoperative dislocations, infection, and limb length inequality was determined. Femoral stem and acetabular cup alignment was quantified using the initial postoperative radiographs. Patient follow-up averaged 12.9 (range 2 to 36) months. There were eight (7.4 %) complications requiring revision surgery in three (2.8 %) patients with three (2.8 %) infections and three (2.8 %) dislocations. Intraoperative complications included one calcar fracture above the lesser trochanter. Leg length inequality >5 mm was present in three (2.8 %) patients. Radiographic analysis showed that femoral neutral alignment was achieved in 95 hips (88.0 %). All femoral stems demonstrated satisfactory fit and fill and no evidence of subsidence, osteolysis, or loosening. An average abduction angle of 44.8° (± 5.3) and average cup anteversion of 16.2° (± 4.2) were also noted. Although the technique with this implant and approach is promising, it does not appear to offer important advantages over standard techniques. However, the findings merit further, long-term study.

  6. RETURN TO DIVISION IA FOOTBALL FOLLOWING A 1ST METATARSOPHALANGEAL JOINT DORSAL DISLOCATION

    PubMed Central

    Cook, Chad; Zarzour, Hap; Moorman, Claude T.

    2010-01-01

    Background. Although rare in occurrence, a dorsal dislocation of the 1st metatarsophalangeal (MTP) joint has been successfully treated using surgical and/or non-operative treatment. No descriptions of conservative intervention following a dorsal dislocation of the MTP joint in an athlete participating in a high contact sport are present in the literature. Objectives. The purpose of this case report is to describe the intervention and clinical reasoning during the rehabilitative process of a collegiate football player diagnosed with a 1st MTP joint dorsal dislocation. The plan of care and return to play criteria used for this athlete are presented. Case Description. The case involved a 19-year-old male Division IA football player, who suffered a traumatic dorsal dislocation of the 1st MTP joint during practice. The dislocation was initially treated on-site by closed reduction. Non-operative management included immobilization, therapeutic exercises, non-steroidal anti-inflammatories, manual treatment, modalities, prophylactic athletic taping, gait training, and a sport specific progression program for full return to Division IA football. Outcomes. Discharge from physical therapy occurred after six weeks of treatment. At discharge, no significant deviations existed during running, burst, and agility related drills. At a six-month follow-up, the patient reported full return to all football activities including contact drills without restrictions. Discussion. This case describes an effective six-week rehabilitation intervention for a collegiate football player who sustained a traumatic great toe dorsal dislocation. Further study is suggested to evaluate the intervention strategies and timeframe for return to contact sports. PMID:21589669

  7. Analyses of outcomes of one-stage operation for treatment of late-diagnosed developmental dislocation of the hip: 864 hips followed for 3.2 to 8.9 years.

    PubMed

    Ning, Bo; Yuan, Yi; Yao, Jie; Zhang, Sichng; Sun, Jun

    2014-11-28

    The one-stage procedure for treatment of older developmental dislocation of the hip (DDH) is used widely. However, the best age group for this operation is still unknown. The aims of our study were to evaluate middle-term outcomes of one-stage surgical treatment of a large number of patients with late-diagnosed DDH, and to explore the best age group for treatment. We retrospectively reviewed 652 patients with a total of 864 hip joints with DDH, all aged >18 months. All the hip joints were treated with one-stage procedures including open reduction, pelvic osteotomy, and femoral shortening. The patients were divided into three groups according to age at surgery: Group I: 1.5-2.5 years; Group II: 2.5-8 years; and Group III: >8 years. The latest clinical and radiographic outcomes, complications and avascular necrosis (AVN) of the femoral head were evaluated and compared among the three groups. The mean age at surgery was 5.8 years (range: 1.5-13.2 years). The average time of follow-up was 6.2 years (range: 3.2-8.9 years). A total of 79.4% of good or excellent outcomes were obtained for clinical functional evaluation according to the McKay classification. For radiographic outcomes, 732 hips (84.7%) were classified as good or excellent according to the Severin classification. A total of 27.4% of all hips had a poor outcome according to the Kalamchi and MacEwen classification for AVN. The poorest outcomes were observed for clinical, radiographic and AVN results in Group III (p < 0.001). Compared with Group I, the better results for clinical and AVN outcomes were found in Group II (p < 0.001). However, similar clinical outcomes were observed between Groups I and II (p > 0.05). A significantly higher incidence of redislocation and residual acetabular dysplasia was observed in Tonnis grade II and III hip dislocation (p < 0.001). One-stage treatment of late-diagnosed DDH had a good outcome in young and middle group. Younger patients achieved better results than older patients. However, the best age group was 2.5-8 years. Tonnis grade II and III DDH is a risk factor for redislocation and residual acetabular dysplasia after the one-stage operation.

  8. Congenital Dislocation of the Hip

    PubMed Central

    Specht, Elmer E.

    1976-01-01

    Congenital dislocation or subluxation of the hip (congenital acetabular dysplasia) is a complete or partial displacement of the femoral head out of the acetabulum. The physical signs essential for diagnosis are age related. In newborns the tests for instability are the most sensitive. After the neonatal period, and until the age of walking, tightness of the adductor muscles is the most reliable sign. Early diagnosis is vital for successful treatment of this partially genetically determined condition. Various therapeutic measures, ranging from abduction splinting to open reduction and osteotomy, may be required. Following diagnosis in the first month of life, the average treatment time in one recent series was only 2.3 months from initiation of therapy to attainment of a normal hip. When the diagnosis was not made until 3 to 6 months of age, ten months of treatment was required to achieve the same outcome. When the diagnosis is not made, or the treatment is not begun until after the age of 6, a normal hip will probably not develop in any patient. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7.Figure 8.Figure 9. PMID:1251603

  9. True congenital dislocation of shoulder: A case report and review of the literature.

    PubMed

    Sudesh, Pebam; Rangdal, Sushil; Bali, Kamal; Kumar, Vishal; Gahlot, Nitesh; Patel, Sandeep

    2010-10-01

    The dislocation of a shoulder joint in infancy is extremely rare and is usually the result of traumatic birth injuries, a sequel to brachial plexus injury, or a true congenital dislocation of shoulder. With more advanced obstetric care, the incidence of first two types has drastically decreased. We report a case of true congenital dislocation of shoulder, second of its kind, in a child who was delivered by cesarean section thereby negating any influence of trauma. We report the case because of its rarity, and review the available literature on this topic. We also discuss the management options when encountered with such a rare case scenario.

  10. Neglected locked vertical patellar dislocation

    PubMed Central

    Gupta, Rakesh Kumar; Gupta, Vinay; Sangwan, Sukhbir Singh; Kamboj, Pradeep

    2012-01-01

    Patellar dislocations occurring about the vertical and horizontal axis are rare and irreducible. The neglected patellar dislocation is still rarer. We describe the clinical presentation and management of a case of neglected vertical patellar dislocation in a 6 year-old boy who sustained an external rotational strain with a laterally directed force to his knee. Initially the diagnosis was missed and 2 months later open reduction was done. The increased tension generated by the rotation of the lateral extensor retinaculum kept the patella locked in the lateral gutter even with the knee in full extension. Traumatic patellar dislocation with rotation around a vertical axis has been described earlier, but no such neglected case has been reported to the best of our knowledge. PMID:23162154

  11. Cement-in-cement acetabular revision with a constrained tripolar component.

    PubMed

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  12. Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.

    PubMed

    Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S

    2017-10-01

    As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Capsular lesions with glenohumeral ligament injuries in patients with primary shoulder dislocation: magnetic resonance imaging and magnetic resonance arthrography evaluation

    PubMed Central

    Liavaag, S; Stiris, M G; Svenningsen, S; Enger, M; Pripp, A H; Brox, J I

    2011-01-01

    The glenohumeral ligaments are important structures for the stability of the shoulder. They are integrated parts of the capsule and are at risk to be injured in a traumatic shoulder dislocation. The aim was to examine the prevalence of capsular ligament lesions in the acute phase and at minimum 3 weeks' follow-up after first-time traumatic shoulder dislocation. Forty-two patients aged 16–40 years were included. All patients underwent computed tomography and magnetic resonance imaging (MRI) scans shortly after the injury and MR-arthrography (MRA) at follow-up. The median time from dislocation to MRI was 7 (range 2–14) days and to MRA 30 (range 21–54) days. We found capsular ligament lesions in 22 patients (52.4%) in the acute stage and in five patients (11.9%) at follow up. Nine patients (21.4%) had a humeral avulsion of the anterior glenohumeral ligament (HAGL lesion) on MRI. Three patients (7.1%) had this lesion at follow-up. The rate of HAGL lesions in the acute stage was higher than reported previously, but the prevalence at follow-up was in keeping with earlier published studies. PMID:21401723

  14. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    PubMed

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Patient-oriented Functional Results of Total Femoral Endoprosthetic Reconstruction Following Oncologic Resection

    PubMed Central

    Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.

    2011-01-01

    Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701

  16. Tapered stems one-third proximally coated have higher complication rates than cylindrical two-third coated stems in patients with high hip dislocation undergoing total hip arthroplasty with step-cut shortening osteotomy.

    PubMed

    Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi

    2017-06-01

    The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Natural substrate lift-off technique for vertical light-emitting diodes

    NASA Astrophysics Data System (ADS)

    Lee, Chia-Yu; Lan, Yu-Pin; Tu, Po-Min; Hsu, Shih-Chieh; Lin, Chien-Chung; Kuo, Hao-Chung; Chi, Gou-Chung; Chang, Chun-Yen

    2014-04-01

    Hexagonal inverted pyramid (HIP) structures and the natural substrate lift-off (NSLO) technique were demonstrated on a GaN-based vertical light-emitting diode (VLED). The HIP structures were formed at the interface between GaN and the sapphire substrate by molten KOH wet etching. The threading dislocation density (TDD) estimated by transmission electron microscopy (TEM) was reduced to 1 × 108 cm-2. Raman spectroscopy indicated that the compressive strain from the bottom GaN/sapphire was effectively released through the HIP structure. With the adoption of the HIP structure and NSLO, the light output power and yield performance of leakage current could be further improved.

  18. Hip Dislocation and Dystocia in Early Medieval Times: Possible Evidence of Labor Maneuver.

    PubMed

    Malgosa, Assumpció; Carrascal, Susana; Piga, Giampaolo; Isidro, Albert

    2016-12-01

    In ancient times, maternal mortality would occur frequently, particularly during labor. Evidence of dystocia resulting in the death of a pregnant woman is very infrequent in paleopathologic literature, with only a few cases being demonstrated. In the early medieval site of Casserres, the skeleton of a young woman with a fetus in the pelvic region was found. Some abnormal findings of the maternal skeleton were evaluated, including a sacral anomaly, femoral head wound, the rare position of the lower left limb with the femoral head dislodged anteriorly and cephalad from the socket, and a fibular fracture. Examining the anomalies all together, a case of anterior hip dislocation related to a McRoberts-like maneuver performed during labor is a plausible explanation of the findings.

  19. An isolated dorso-medial dislocation of navicular bone: A case report.

    PubMed

    Singh, Varun Kumar; Kashyap, Abhishek; Vargaonkar, Gauresh; Kumar, Ramesh

    2015-03-01

    An isolated dislocation of tarsal navicular is extremely rare injury. Usually it is associated with fracture of navicular itself or other tarsal bones of foot along with disruption of medial or lateral column of foot. Mechanism of injury is complex but usually a severe abduction force is required to produce such injury in a planter flexed foot. A 30 year old male presented with isolated navicular dislocation. Management required open reduction and fixation with k-wires. These injuries have specific complications including avascular necrosis of navicular and post-traumatic arthritis.

  20. Atlantoaxial manual realignment in a patient with traumatic atlantoaxial joint disruption.

    PubMed

    Goel, Atul; Figueiredo, Antonio; Maheshwari, Shradha; Shah, Abhidha

    2010-05-01

    We report a patient with complex traumatic translatory atlantoaxial dislocation, who we treated by joint exposure and reduction of the dislocation by facet manipulation and subsequent plate and screw atlantoaxial fixation. A 28-year-old male had fallen 7.6m (25 feet), and following the fall had severe neck pain but no neurological deficit. Investigations revealed a fracture at the base of the odontoid process and posterior displacement of the entire atlas over the axis, resulting in a translatory atlantoaxial dislocation. Head traction failed as he developed severe vertigo following its application. The patient was operated upon in a prone position. We opened the atlantoaxial joint and realigned the facets using distraction and manipulation techniques and secured the joint using a plate and screw interarticular method. The patient tolerated the treatment well and was symptom-free after 28 months. Postoperative images showed good craniovertebral alignment. Although technically challenging, direct manipulation of the facets of the atlas and axis can result in excellent craniovertebral realignment.

  1. Blunt traumatic axillary artery truncation, in the absence of associated fracture.

    PubMed

    Bokser, Emily; Caputo, William; Hahn, Barry; Greenstein, Josh

    2018-02-01

    Axillary artery injuries can be associated with both proximal humeral fractures (Naouli et al., 2016; Ng et al., 2016) [1,2] as well as shoulder dislocations (Leclerc et al., 2017; Karnes et al., 2016) [3,4]. We report a rare case of an isolated axillary artery truncation following blunt trauma without any associated fracture or dislocation. A 58-year-old male presented to the emergency department for evaluation after falling on his outstretched right arm. The patient was found to have an absent right radial pulse with decreased sensation to the right arm. Point of care ultrasound showed findings suspicious for traumatic axillary artery injury, and X-rays did not demonstrate any fracture. Computed tomography with angiography confirmed axillary artery truncation with active extravasation. The patient underwent successful vascular repair with an axillary artery bypass. Although extremity injuries are common in emergency departments, emergency physicians need to recognize the risk for vascular injuries, even without associated fracture or dislocation. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Septic shoulder presenting as a shoulder dislocation in the pediatric patient: a case report.

    PubMed

    Maguire, Kathleen J; Otsuka, Norman Y

    2017-05-01

    Shoulder dislocation is relatively uncommon in the younger pediatric population. Because of the relative strength of the surrounding soft tissue structures of the shoulder compared with the proximal humeral physis, subluxation or dislocation resulting from a traumatic event or application of force is rare and instead a proximal humeral physeal injury occurs. Case presentation - We present a 5-year-old male who presented to the office with post-traumatic left shoulder pain for about 1 week. Radiographs of the left shoulder indicated inferior subluxation of the humeral head. He was ultimately diagnosed and treated for a septic shoulder. Septic arthritis of the glenohumeral joint accounts for about 3% of all septic arthritis cases. About half of the pediatric patients with a septic arthritis will present with a concomitant osteomyelitis about the joint involved. Widening of the glenohumeral joint and subluxation clinically as well as radiographically have been described in cases of large joint effusions because of an increase in intra-articular fluid in adults. This inferior subluxation is often noted without a frank dislocation. The case described in this report is unique in that this is the first to describe a pediatric septic shoulder presenting as a shoulder subluxation. Given the rarity of pediatric shoulder dislocations and subluxations, the pediatric orthopaedist and pediatrician should maintain a suspicion for a septic joint. Level V.

  3. Pathologic changes associated with shoulder dislocations. Arthroscopic and physical examination findings in first-time, traumatic anterior dislocations.

    PubMed

    Taylor, D C; Arciero, R A

    1997-01-01

    This prospective observational study was performed on young patients, less than 24 years old, with first-time, traumatic anterior shoulder dislocations. These patients were offered either arthroscopic or nonoperative treatment. Fifty-three patients chose nonoperative treatment. Sixty-three patients elected to have arthroscopic procedures. The average patient age was 19.6 years. There were 59 men and 4 women. All procedures were performed within 10 days of dislocation. All 63 patients had hemarthrosis. Sixty-one of 63 (97%) patients treated surgically had complete detachment of the capsuloligamentous complex from the glenoid rim and neck (Perthes-Bankart lesion), with no gross evidence of intracapsular injury. Of the other two patients, one had an avulsion of the inferior glenohumeral ligament from the neck of the humerus, and one had an interstitial capsular tear adjacent to the intact glenoid labrum. Fifty-seven patients had Hill-Sachs lesions; none were large. There were six superior labral anterior posterior lesions, two with detachment of the biceps tendon. There were no rotator cuff tears. Of the 53 nonoperatively treated patients, 48 (90%) have developed recurrent instability. In this population, the capsulolabral avulsion appeared to be the primary gross pathologic lesion after a first-time dislocation. These findings, associated with the 90% nonoperative recurrence rate, suggest a strong association between recurrent instability and the Perthes-Bankart lesion in this population.

  4. Disparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening.

    PubMed

    Kyung, Bong Soo; Lee, Soon Hyuck; Jeong, Woong Kyo; Park, Si Young

    2016-06-01

    For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening strategy, we assessed the agreement among the methods; clinical examination by an experienced pediatric orthopedic surgeon, sonographic morphology, and sonographic stability. From January 2004 to June 2009, a single experienced pediatric orthopedic surgeon performed clinical hip screenings for 2,686 infants in the neonatal unit and 43 infants who were referred due to impressions of hip dysplasia before 3 months of age. Among them, 156 clinically unstable or high-risk babies selectively received bilateral hip ultrasound examinations performed by the same surgeon using the modified Graf method. The results were analyzed statistically to detect any correlations between the clinical and sonographic findings. Although a single experienced orthopedic surgeon conducted all examinations, we detected only a limited relationship between the results of clinical and ultrasound examinations. Ninety-three percent of the clinically subluxatable hips were normal or immature based on static ultrasound examination, and 74% of dislocating hips and 67% of limited abduction hips presented with the morphology below Graf IIa. A total of 80% of clinically subluxatable, 42% of dislocating and 67% of limited abduction hips appeared stable or exhibited minor instability on dynamic ultrasound examination. About 7% of clinically normal hips were abnormal upon ultrasound examination; 5% showed major instability and 3% showed dysplasia above Graf IIc. Clinical stability had small coefficients between ultrasound examinations; 0.39 for sonographic stability and 0.37 for sonographic morphology. Between sonographic stability and morphology, although 71% of hips with major instability showed normal or immature morphology according to static ultrasound examination, the coefficient was as high as 0.64. Discrepancies between clinical and ultrasound examinations were present even if almost all of the exams were performed by a single experienced pediatric orthopedic surgeon. In relation to screening for DDH, it is recommended that both sonographic morphology and stability be checked in addition to clinical examination.

  5. Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty.

    PubMed

    Gonzalez, Amanda Inez; Bartolone, Placido; Lubbeke, Anne; Dupuis Lozeron, Elise; Peter, Robin; Hoffmeyer, Pierre; Christofilopoulos, Panayiotis

    2017-02-01

    Background and purpose - Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period using either the dual-mobility cup or the unipolar cup. Methods - We used a prospective hospital registry-based cohort including all total and cup-only revision THAs performed between 2003 and 2013. The cups used were either dual-mobility or unipolar; the choice was made according to the preference of the surgeon. 316 revision THAs were included. The mean age of the cohort was 69 (25-98) years and 160 THAs (51%) were performed in women. The dual-mobility group (group 1) included 150 THAs (48%) and the mean length of follow-up was 31 (0-128) months. The unipolar group (group 2) included 166 THAs (53%) and the mean length of follow-up was 52 (0-136) months. Results - The incidence of dislocation within 6 months was significantly lower with the dual-mobility cup than with the unipolar cup (2.7% vs. 7.8%). The unadjusted risk ratio (RR) was 0.34 (95% CI: 0.11-1.02) and the adjusted RR was 0.28 (95% CI: 0.09-0.87). The number of patients needed to treat with a dual-mobility cup in order to prevent 1 case of dislocation was 19. The unadjusted incidence rate ratio for all-cause re-revision in the dual-mobility group compared to the unipolar group was 0.6 (95% CI: 0.3-1.4). Interpretation - Use of a dual-mobility rather than a unipolar cup in revision THA reduced the risk of dislocation within 6 months.

  6. Traumatic anterior dislocation of the crystalline lens and its surgical management.

    PubMed

    Srećković, Sunčica; Janićijević Petrović, Mirjana; Jovanović, Svetlana; Paunović, Svetlana; Sarenac, Tatjana

    2012-02-01

    This paper reports a case of a 57-year old female who had sustained a blunt ocular trauma resulting in anterior dislocation of the crystalline lens and acute painful visual loss in the left eye. The patient was managed with anterior chamber intracapsular phacoemulsification through a small anterior capsulotomy, pars plana vitrectomy, and surgical iridotomy. Aphakia was corrected by a contact lens. Two months after the surgery, the best corrected visual acuity was 0.9 in the left eye. The vision and retina remained stable in her follow-up examination 1 year later. Anterior dislocation of the crystalline lens can cause severe complications so that dislocated lens should be removed immediately.

  7. Avulsion fracture of an ossified pes anserinus tendon post-lateral patellar dislocation.

    PubMed

    Albtoush, Omar M; Taib, Abtehag A; Horger, Marius; Springer, Fabian

    2018-05-01

    The pes anserinus is a common tendon comprising the tendinous insertions of the sartorius, gracilis, and semitendinosus muscles. It inserts at the anteromedial aspect of the tibia and plays a significant role in stabilization of the medial side of the knee joint. The current article presents a case with recurrent lateral patellar dislocations causing chronic stress along the medial knee stabilizers and consecutive enthesophyte formation at the insertion of the pes anserinus tendon that showed a transverse fracture upon a subsequent incident of traumatic lateral patellar dislocation. Avulsion injuries of the pes anserinus tendon are rarely encountered, and to our knowledge, association with recurrent lateral patellar dislocations has not been described before.

  8. Modified anterior-only reduction and fixation for traumatic cervical facet dislocation (AO type C injuries).

    PubMed

    Kanna, Rishi M; Shetty, Ajoy P; Rajasekaran, S

    2018-06-01

    Surgical reduction of uni and bi-facetal dislocations of the cervical spine (AO type C injuries) can be performed by posterior, anterior or combined approaches. Ease of access, low infection rates and less risks of neurological worsening has popularized anterior approach. However, the reduction of locked cervical facets can be intricate through anterior approach. We analyzed the safety, efficacy and outcomes at a minimum 1 year, of a novel anterior reduction technique for consecutively treated cervical facet dislocations. Patients with single level traumatic sub-axial cervical dislocation (n = 39) treated by this modified anterior technique were studied. The technique involved standard Smith-Robinson approach, discectomy beyond PLL, use of inter-laminar distracter to distract while Caspar pins were used as "joysticks" (either flexion-extension or lateral rotation moments are provided), to reduce the sub-luxed facets. Among 51 patients with cervical type C injury treated during the study period, 4 patients who had spontaneous reduction and 8 treated by planned global fusion were excluded. 39 patients of mean age 49.9 years were studied. The levels of injury included (C3-4 = 2, C4-5 = 5, C5-6 = 20, C6-7 = 12). 18 were bi-facetal and 21 were uni-facetal dislocation. One facet was fractured in 17 and both in 5 patients. 30% (n = 13) had a concomitant disc prolapse. The neurological status was as follows: 9 ASIA A, 9 ASIA C, 13 ASIA D and 8 ASIA E. All the patients were successfully reduced by this technique and fixed with anterior locking cervical locking plates. No supplemental posterior surgery was performed. 22 patients with incomplete deficit showed recovery. The mean follow-up was 14.3 months and there was no implant failure except one patient who had partial loss of the reduction. Patients with traumatic sub-axial cervical dislocation (AO type C injuries) can be safely and effectively reduced by this technique. Other advantages include minimal blood loss, less risks of infection, shorted fusion zone, good fusion rate and neurological recovery.

  9. Report of a new case and clinical delineation of mosaic trisomy 9 syndrome

    PubMed Central

    Sánchez, José María; Fijtman, Nora; Migliorini, Ana María

    1982-01-01

    A newborn girl with trisomy 9 mosaicism is reported. Clinical findings included major malformations: bilateral hip dislocation, dislocation of the left knee, extreme micrognathia, and microsomy. Up to date, 11 liveborn infants with trisomy 9 have been reported, which allows us to make a karyotype/phenotype correlation. Minimal clinical diagnostic criteria are defined, on the basis of which the presence of this syndrome can be suspected. Images PMID:7143394

  10. Atlanto-occipital dislocation: Case report and discussion.

    PubMed

    Asfaw, Tehetena; Chow, Bernard; Frederiksen, Ryan A

    2011-01-01

    Traumatic atlanto-occipital dislocation is an uncommon injury that frequently results in either a fatal outcome or severe neurologic deficit. This diagnosis must be considered for any patients who may have had cervical spine damage after high trauma, even in the absence of neurologic signs, as there have been reports of cases without neurologic impairment. In addition to radiographic examination, including lateral cervical radiographs, supplemental imaging with CT or MRI may be required to confirm diagnosis in equivocal cases, and to help in evaluation of bone and nervous structures. Moreover, these modalities allow measurement of the magnitude of dislocation and aid in classification of type of dislocation, which helps guide management. A systematic approach to evaluating the cranio-cervical relationship is critical to identifying atlanto-occipital dislocation. This case report presents and discusses imaging findings that will assist in the diagnosis of atlanto-occipital dislocation.

  11. The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.

    PubMed

    Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R

    2017-05-01

    Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.

  12. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff.

    PubMed

    Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S

    2012-05-01

    Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.

  13. Subtalar dislocation without associated fractures: Case report and review of literature

    PubMed Central

    Giannoulis, Dionisios; Papadopoulos, Dimitrios V; Lykissas, Marios G; Koulouvaris, Panagiotis; Gkiatas, Ioannis; Mavrodontidis, Alexandros

    2015-01-01

    Isolated subtalar dislocations are unusual injuries due to the inherent instability of the talus. Subtalar dislocations are frequently associated with fractures of the malleoli, the talus, the calcaneus or the fifth metatarsal. Four types of subtalar dislocation have been described according to the direction of the foot in relation to the talus: medial, lateral posterior and anterior. It has been shown that some of these dislocations may spontaneously reduce. A rare case of a 36-year-old male patient who sustained a closed medial subtalar dislocation without any associated fractures of the ankle is reported. The patient suffered a pure closed medial subtalar dislocation that is hardly reported in the literature. Six months after injury the patient did not report any pain, had a satisfactory range of motion, and no signs of residual instability or early posttraumatic osteoarthritis. The traumatic mechanism, the treatment options, and the importance of a stable and prompt closed reduction and early mobilization are discussed. PMID:25893182

  14. Hip Dislocation Increases Roughness of Oxidized Zirconium Femoral Heads in Total Hip Arthroplasty: An Analysis of 59 Retrievals

    PubMed Central

    Moussa, Mohamed E.; Esposito, Christina I.; Elpers, Marcella E.; Wright, Timothy M.; Padgett, Douglas E.

    2014-01-01

    The aims of this study were to assess damage on the surface of retrieved oxidized zirconium metal (OxZr) femoral heads, to measure surface roughness of scratches, and to evaluate the extent of surface effacement using scanning electron microscopy (SEM). Ceramic zirconia-toughened alumina (ZTA) heads were analyzed for comparison. OxZr femoral heads explanted for recurrent dislocation had the most severe damage (p<0.001). The median surface roughness of damaged OxZr femoral heads was 1.49μm, compared to 0.084μm for damaged ZTA heads and 0.052μm for undamaged OxZr (p<0.001). This may be of clinical concern because increased surface roughness has the potential to increase the wear of polyethylene liners articulating against these OxZr heads in THA. PMID:25443362

  15. Traumatic ipsilateral multiple open metatarsal and calcaneal fractures with first metatarsophalangeal joint dislocation: a case report.

    PubMed

    Ozkan, Namik Kemal; Unay, Koray; Cift, Hakan; Eceviz, Engin; Ozkan, Korhan

    2010-06-01

    A 17-year-old man fell from a height of 10 m onto his right forefoot and sustained ipsilateral calcaneal, comminuted cuboid, and second, third, and fourth metatarsal neck fractures and first metatarsophalangeal joint open dislocation. This report discusses this rare injury. The authors believe that initial debridement with immediate surgical fixation and reduction with appropriate antibiotic treatment saved the patient's extremity.

  16. I.S.Mu.L.T. first-time patellar dislocation guidelines

    PubMed Central

    Vetrano, Mario; Oliva, Francesco; Bisicchia, Salvatore; Bossa, Michela; De Carli, Angelo; Di Lorenzo, Luigi; Erroi, Davide; Forte, Alfonso; Foti, Calogero; Frizziero, Antonio; Gasparre, Giuseppe; Via, Alessio Giai; Innocenti, Bernardo; Longo, Umile Giuseppe; Mahmoud, Asmaa; Masiero, Stefano; Mazza, Daniele; Natali, Simone; Notarangelo, Christian; Osti, Leonardo; Padulo, Johnny; Pellicciari, Leonardo; Perroni, Fabrizio; Piccirilli, Eleonora; Ramponi, Carlo; Salvatore, Giuseppe; Panni, Alfredo Schiavone; Suarez, Tania; Tarantino, Umberto; Vittadini, Filippo; Vulpiani, Maria Chiara; Ferretti, Andrea; Maffulli, Nicola

    2017-01-01

    Summary Primary traumatic patellar dislocation is common, particularly in young active individuals. A consensus on its management is still lacking. The present work provides easily accessible guidelines to be considered as recommendations for a good clinical practice developed through a process of systematic review of the literature and expert opinion, to improve the quality of care and rationalize the use of resources. Level of evidence: Ia. PMID:28717605

  17. Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.

    PubMed

    Beck, Sierra; Chilstrom, Mikaela

    2013-02-01

    Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Patient-oriented functional results of total femoral endoprosthetic reconstruction following oncologic resection.

    PubMed

    Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C

    2011-11-01

    Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.

  19. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review.

    PubMed

    Snijders, Thom E; Willemsen, Koen; van Gaalen, Steven M; Castelein, Rene M; Weinans, Harrie; de Gast, Arthur

    2018-05-01

    Dislocation is one of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. Twenty eight relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.

  20. Innovations in the management of hip fractures.

    PubMed

    Teasdall, Robert D; Webb, Lawrence X

    2003-08-01

    Hip fractures include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region that is exposed to large compressive stresses. Implants used to address these fractures must accommodate significant loads while the fractures consolidate. Complications secondary to hip fractures produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  1. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    PubMed

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  2. Mid-Term Outcomes After Open Reduction Internal Fixation of Proximal Interphalangeal Joint Dorsal Fracture-Dislocations Through a Volar, Shotgun Approach and a Review of the Literature

    PubMed Central

    Giugale, Juan Marcelo; Wang, Juntian; Kaufmann, Robert A.; Fowler, John R.

    2017-01-01

    Background: Proximal interphalangeal (PIP) fracture dislocations remain a complex injury pattern to treat. There are several treatment methods available aimed to restore stability, preserve range of motion, and reconstitute the articular surface. This study looked at the mid-term clinical and radiographic results of open reduction internal fixation through a shotgun approach of comminuted PIP fracture dislocations. Methods: A retrospective review was conducted of all PIP fracture dislocations treated through a volar, shotgun approach at a single institution over a 15-year period. Patients identified were contacted and asked to return to the office for clinical and radiographic evaluation. Patient reported outcomes were assessed with the Michigan hand questionnaire (MHQ) and visual analog scale (VAS) for pain. Results: 5 patients returned to the office for further evaluation with average follow-up of 69 months (range, 33-133 months). 3 patients were found to have post traumatic arthritis on radiographs. 1 case had recurrent instability and one case had a deep infection, both necessitating further surgical intervention. Average PIP arc of motion was found to be 79°. Average VAS score of 0 and MHQ result of 95 (out of a possible score of 100) indicating no residual pain and excellent functionality of the affected hand. Conclusion: Open reduction internal fixation of comminuted PIP fracture dislocations utilizing the volar, shotgun approach provides excellent mid-term functional results despite the high incidence of post traumatic arthritis. PMID:29151999

  3. Gradual Reduction of Chronic Fracture Dislocation of the Ankle Using Ilizarov/Taylor Spatial Frame

    PubMed Central

    Deland, Jonathan T.; Rozbruch, S. Robert

    2010-01-01

    With the advances in trauma care, chronic fracture dislocation of the ankle is not a condition commonly seen in modern clinical practice. When encountered, it can be difficult to preserve the ankle joint. We present a case of a 65-year-old female, with a chronic fracture dislocation of the ankle. The ankle joint was subluxated with posterior translation of the talus, displacement of the posterior malleolus fragment, and a distal fibula fracture. A minimally traumatic approach was devised to treat this complex fracture dislocation which included gradual reduction of the ankle with a Taylor spatial frame, followed by stabilization with internal fixation and removal of the frame. Bony union and restoration of the ankle joint congruency was achieved. PMID:22294963

  4. Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up.

    PubMed

    Acker, A; Fischer, J-F; Aminian, K; Lécureux, E; Jolles, B M

    2017-02-01

    Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations. Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations. III, retrospective case-control series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?

    PubMed

    Yoon, Byung-Ho; Lee, Young-Kyun; Yoo, Jeong Joon; Kim, Hee Joong; Koo, Kyung-Hoi

    2014-03-01

    Patients with residual poliomyelitis can have advanced degenerative arthritis of the hip in the paralytic limb or the nonparalytic contralateral limb. Although THA is a treatment option for some of these patients, there are few studies regarding THA in this patient population. We therefore reviewed a group of patients with residual poliomyelitis who underwent cementless THA on either their paralytic limb or nonparalytic limb to assess (1) Harris hip scores, (2) radiographic results, including implant loosening, (3) complications, including dislocation, and (4) limb length discrepancy after recovery from surgery. From January 2000 to December 2009, 10 patients with residual poliomyelitis (10 hips, four paralytic limbs and six nonparalytic contralateral limbs) underwent THA using cementless prostheses. Harris hip scores, complications, and leg length discrepancy were determined by chart review, and confirmed by questionnaire and examination; radiographs were reviewed by two observers for this study. Followup was available for all 10 patients at a minimum of 3 years (median, 7 years; range, 3.4-13 years). Surgery was done at the same side of the paralytic limb in four hips and contralateral to the paralytic limb in six. All patients had pain relief and improvement in function; the Harris hip score improved from mean of 68 preoperatively to 92 at last followup (p = 0.043). However, only three patients had complete pain relief. One hip dislocated, which was treated successfully with closed reduction and a hip spica cast for 2 months. There was no loosening or osteolysis in this series. Leg length discrepancy improved after the index operation, but only in the THAs performed in the paralytic limbs. Cementless THA may be suitable for painful hips in adult patients with residual poliomyelitis. Nonetheless, these patients should be informed of the possibility of mild residual pain and persistent leg length discrepancy, particularly patients whose THA is performed on the limb that was not affected by polio (ie, the nonparalytic contralateral limb). Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

  6. Position of Immobilization After First-Time Traumatic Anterior Glenohumeral Dislocation: A Literature Review

    PubMed Central

    Gutkowska, Olga; Martynkiewicz, Jacek; Gosk, Jerzy

    2017-01-01

    Anterior glenohumeral dislocation affects about 2% of the general population during the lifetime. The incidence of traumatic glenohumeral dislocation ranges from 8.2 to 26.69 per 100 000 population per year. The most common complication is recurrent dislocation occurring in 17–96% of the patients. The majority of patients are treated conservatively by closed reduction and immobilization in internal rotation for 2–3 weeks. However, no clear conservative treatment protocol exists. Immobilization in external rotation can be considered an alternative. A range of external rotation braces are commercially available. The purpose of this work was to review the current literature on conservative management of glenohumeral dislocation and to compare the results of immobilization in internal and external rotation. A comprehensive literature search and review was performed using the keywords “glenohumeral dislocation”, “shoulder dislocation”, “immobilization”, “external rotation”, and “recurrent dislocation” in PubMed, MEDLINE, Cochrane Library, Scopus, and Google Scholar databases from their inceptions to May 2016. Three cadaveric studies, 6 imaging studies, 10 clinical studies, and 4 meta-analyses were identified. The total number of 734 patients were included in the clinical studies. Literature analysis revealed better coaptation of the labrum on the glenoid rim in external rotation in cadaveric and imaging studies. However, this tendency was not confirmed by lower redislocation rates or better quality of life in clinical studies. On the basis of the available literature, we cannot confirm the superiority of immobilization in external rotation after glenohumeral dislocation when compared to internal rotation. A yet-to-be-determined group of patients with specific labroligamentous injury pattern may benefit from immobilization in external rotation. Further studies are needed to identify these patients. PMID:28710344

  7. A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically.

    PubMed

    Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya

    2017-12-01

    Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far.

  8. A rare case of traumatic subretinal migration of crystalline lens, corroborated histologically

    PubMed Central

    Bawankar, Pritam; Das, Dipankar; Agarwal, Balmukund; Bhattacharjee, Kasturi; Tayab, Shahinur; Deka, Panna; Singh, Anshul; Borah, Erani; Dhar, Shriya

    2017-01-01

    Blunt trauma is the most common cause of posterior dislocation of the crystalline lens. We describe a rare case of subretinal migration of crystalline lens through the giant retinal tear following blunt ocular trauma. This incidental finding of subretinal dislocation of lens following blunt ocular trauma was confirmed on histopathological examination of the enucleated eye. This complication has not been described by histopathological examination in literature so far. PMID:29208844

  9. Ankylosing Spondylitis Increases Perioperative and Postoperative Complications After Total Hip Arthroplasty.

    PubMed

    Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R

    2017-08-01

    Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Unplanned hip arthroplasty imposes clinical and cost burdens on treating institutions.

    PubMed

    Kamath, Atul F; Austin, Daniel C; Derman, Peter B; Israelite, Craig L

    2013-12-01

    Emergent surgery has been shown to be a risk factor for perioperative complications. Studies suggest that patient morbidity is greater with an unplanned hip arthroplasty, although it is controversial whether unplanned procedures also result in higher patient mortality. The financial impact of these procedures is not fully understood, as the costs of unplanned primary hip arthroplasties have not been studied previously. We asked: (1) What are the institutional costs associated with unplanned hip arthroplasties (primary THA, hemiarthroplasty, revision arthroplasty, including treatment of periprosthetic fractures, dislocations, and infections)? (2) Does timing of surgery (urgent/unplanned versus elective) influence perioperative outcomes such as mortality, length of stay, or need for advanced care? (3) What diagnoses are associated with unplanned surgery and are treated urgently most often? (4) Do demographics and insurance status differ between admission types (unplanned versus elective hip arthroplasty)? We prospectively followed all 419 patients who were admitted to our Level I trauma center in 2011 for procedures including primary THA, hemiarthroplasty, and revision arthroplasty, including the treatment of periprosthetic fractures, dislocations, and infections. Fifty-seven patients who were treated urgently on an unplanned basis were compared with 362 patients who were treated electively. Demographics, admission diagnoses, complications, and costs were recorded and analyzed statistically. Median total costs were 24% greater for patients admitted for unplanned hip arthroplasties (USD 18,206 [USD 15,261-27,491] versus USD 14,644 [USD 13,511-16,309]; p < 0.0001) for patients admitted for elective arthroplasties. Patients with unplanned admissions had a 67% longer median hospital stay (5 days [range, 4-9 days] versus 3 days [range, 3-4 days]; p < 0.0001) for patients with elective admissions. Mortality rates were equivalent between groups (p = 1.0). Femoral fracture (p < 0.0001), periprosthetic fracture (p = 0.01), prosthetic infection (p = 0.005), and prosthetic dislocation (p < 0.0001) were observed at higher rates in the patients with unplanned admissions. These patients were older (p = 0.04), less likely to have commercial insurance (p < 0.0001), more likely to be transferred from another institution (p < 0.0001), and more likely to undergo a revision procedure (p < 0.0001). Unplanned arthroplasty and urgent surgery are associated with increased financial and clinical burdens, which must be accounted for when considering bundled quality and reimbursement measures for these procedures.

  11. Comparative analysis of gene expression profiles of hip articular cartilage between non-traumatic necrosis and osteoarthritis.

    PubMed

    Wang, Wenyu; Liu, Yang; Hao, Jingcan; Zheng, Shuyu; Wen, Yan; Xiao, Xiao; He, Awen; Fan, Qianrui; Zhang, Feng; Liu, Ruiyu

    2016-10-10

    Hip cartilage destruction is consistently observed in the non-traumatic osteonecrosis of femoral head (NOFH) and accelerates its bone necrosis. The molecular mechanism underlying the cartilage damage of NOFH remains elusive. In this study, we conducted a systematically comparative study of gene expression profiles between NOFH and osteoarthritis (OA). Hip articular cartilage specimens were collected from 12 NOFH patients and 12 controls with traumatic femoral neck fracture for microarray (n=4) and quantitative real-time PCR validation experiments (n=8). Gene expression profiling of articular cartilage was performed using Agilent Human 4×44K Microarray chip. The accuracy of microarray experiment was further validated by qRT-PCR. Gene expression results of OA hip cartilage were derived from previously published study. Significance Analysis of Microarrays (SAM) software was applied for identifying differently expressed genes. Gene ontology (GO) and pathway enrichment analysis were conducted by Gene Set Enrichment Analysis software and DAVID tool, respectively. Totally, 27 differently expressed genes were identified for NOFH. Comparing the gene expression profiles of NOFH cartilage and OA cartilage detected 8 common differently expressed genes, including COL5A1, OGN, ANGPTL4, CRIP1, NFIL3, METRNL, ID2 and STEAP1. GO comparative analysis identified 10 common significant GO terms, mainly implicated in apoptosis and development process. Pathway comparative analysis observed that ECM-receptor interaction pathway and focal adhesion pathway were enriched in the differently expressed genes of both NOFH and hip OA. In conclusion, we identified a set of differently expressed genes, GO and pathways for NOFH articular destruction, some of which were also involved in the hip OA. Our study results may help to reveal the pathogenetic similarities and differences of cartilage damage of NOFH and hip OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Orthopaedic manifestations of campomelic dysplasia.

    PubMed

    Khoshhal, Khalid; Letts, R Mervyn

    2002-08-01

    Campomelic dysplasia is a rare form of congenital dwarfism associated with potentially fatal respiratory insufficiency. There are several types of campomelic dysplasia; however, it is characterized by the presence of anteriorly bowed tibias with cutaneous dimpling, anterolaterally bowed femurs, thoracic kyphoscoliosis, hypoplastic scapulas, and absence or delayed ossification of thoracic pedicles. With improving treatment of respiratory insufficiency, the survival rate of affected infants has increased, thereby necessitating treatment of the musculoskeletal malformations to prevent additional morbidity. In an attempt to increase awareness of the presentation of infants with campomelic dysplasia and to emphasize the difficulties of treating associated developmental dislocation of the hip early, the current authors report the case of a 2-year-old girl with campomelic dysplasia who was treated for dislocation of the right hip. The postoperative course of this child was complicated seriously by several apneic episodes secondary to tracheobronchial malacia for which she required admission to the pediatric intensive care unit.

  13. High-quality vertical light emitting diodes fabrication by mechanical lift-off technique

    NASA Astrophysics Data System (ADS)

    Tu, Po-Min; Hsu, Shih-Chieh; Chang, Chun-Yen

    2011-10-01

    We report the fabrication of mechanical lift-off high quality thin GaN with Hexagonal Inversed Pyramid (HIP) structures for vertical light emitting diodes (V-LEDs). The HIP structures were formed at the GaN/sapphire substrate interface under high temperature during KOH wet etching process. The average threading dislocation density (TDD) was estimated by transmission electron microscopy (TEM) and found the reduction from 2×109 to 1×108 cm-2. Raman spectroscopy analysis revealed that the compressive stress of GaN epilayer was effectively relieved in the thin-GaN LED with HIP structures. Finally, the mechanical lift-off process is claimed to be successful by using the HIP structures as a sacrificial layer during wafer bonding process.

  14. Design of a hip prosthetic tribometer based on salat gait cycle

    NASA Astrophysics Data System (ADS)

    Towijaya, T.; Ismail, R.; Jamari, J.

    2017-01-01

    Indonesia is the country with the largest muslim population in the world, most of the inhabitants do salat every day. THR (Total Hip Replacement) patients are prohibited from doing salat in normal gait. It leads to the damage of the hip joint prostheses due to impingement and dislocation.This paper reports the design of a pin-on-ring tribometer which is used to measure and analyze the wear volume and the impingement of hip joint prostheses during salat. The modifications of the femoral head and acetabular cup holder are performed to design the reciprocating motion for the movement of the hip prostheses. The interesting finding of the present research is a new mechanism of linked-bar which leads to the feasibility of the measurement of the wear volume and the impingement for THR patients during salat.

  15. [Application of computer-aided osteotomy template design in treatment of developmental dysplasia of the hip with steel osteotomy].

    PubMed

    Tong, Kuang; Zhang, Yuanzhi; Zhang, Sheng; Yu, Bin

    2013-06-01

    To provide an accurate method for osteotomy in the treatment of developmental dysplasia of the hip with steel osteotomy by three-dimensional reconstruction and Reverse Engineering technique. Between January 2011 and December 2012, 13 children with developmental dysplasia of the hip underwent steel osteotomy. 3D CT scan pelvic images were obtained and transferred via a DICOM network into a computer workstation to construct 3D models of the hip using Materialise Mimics 14.1 software in STL format. These models were imported into Imageware 12.0 software for steel osteotomy simulation until a stable hip was attained in the anatomical position for dislocation or subluxation of the hip in older children. The osteotomy navigational templates were designed according to the anatomical features after a stable hip was reconstructed. These navigational templates were manufactured using a rapid prototyping technique. The reconstruction hips in these children show good matching property and acetabulum cover. The computer-aided design of osteotomy template provides personalized and accurate solutions in the treatment of developmental dysplasia of the hip with steel osteotomy in older children.

  16. Primary total hip replacement for displaced subcapital fractures of the femur.

    PubMed

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  17. Instability of total hip replacement: A clinical study and determination of its risk factors.

    PubMed

    Ezquerra-Herrando, L; Seral-García, B; Quilez, M P; Pérez, M A; Albareda-Albareda, J

    2015-01-01

    To determine the risk factors associated with prosthetic dislocation and simulate a finite element model to determine the safe range of movement of various inclination and anteversion cup positions. Retrospective Case Control study with 46 dislocated patients from 1994 to 2011. 83 randomly selected patients. Dislocation risk factors described in the literature were collected. A prosthetic model was simulated using finite elements with 28, 32, 36 mm heads, and a 52 mm cup. Acetabular position was 25°, 40°, and 60° tilt and with 0°, 15° and 25° anteversion. In extension of 0° and flexion of 90°, internal and external rotation was applied to analyze the range of movement, maximum resisting moment, and stress distribution in the acetabulum to impingement and dislocation. There was greater dislocation in older patients (p=0.002). Higher dislocation in fractures than in osteoarthritis (p=0.001). Less anteversion in dislocated patients (p=0.043). Longer femoral neck in dislocated patients (p=0.002). Finite element model: lower dislocation when there is more anteversion, tilt and bigger femoral heads. Advanced age and fractures are the major risk factors for dislocation. "Safe zone" of movement for dislocation avoidance is 40°-60° tilt and 15°-25° anteversion. Both the defect and excess of soft tissue tension predispose to dislocation. Bigger femoral heads are more stable. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  18. Impact of structural and economic factors on hospitalization costs, inpatient mortality, and treatment type of traumatic hip fractures in Switzerland.

    PubMed

    Mehra, Tarun; Moos, Rudolf M; Seifert, Burkhardt; Bopp, Matthias; Senn, Oliver; Simmen, Hans-Peter; Neuhaus, Valentin; Ciritsis, Bernhard

    2017-12-01

    The assessment of structural and potentially economic factors determining cost, treatment type, and inpatient mortality of traumatic hip fractures are important health policy issues. We showed that insurance status and treatment in university hospitals were significantly associated with treatment type (i.e., primary hip replacement), cost, and lower inpatient mortality respectively. The purpose of this study was to determine the influence of the structural level of hospital care and patient insurance type on treatment, hospitalization cost, and inpatient mortality in cases with traumatic hip fractures in Switzerland. The Swiss national medical statistic 2011-2012 was screened for adults with hip fracture as primary diagnosis. Gender, age, insurance type, year of discharge, hospital infrastructure level, length-of-stay, case weight, reason for discharge, and all coded diagnoses and procedures were extracted. Descriptive statistics and multivariate logistic regression with treatment by primary hip replacement as well as inpatient mortality as dependent variables were performed. We obtained 24,678 inpatient case records from the medical statistic. Hospitalization costs were calculated from a second dataset, the Swiss national cost statistic (7528 cases with hip fractures, discharged in 2012). Average inpatient costs per case were the highest for discharges from university hospitals (US$21,471, SD US$17,015) and the lowest in basic coverage hospitals (US$18,291, SD US$12,635). Controlling for other variables, higher costs for hip fracture treatment at university hospitals were significant in multivariate regression (p < 0.001). University hospitals had a lower inpatient mortality rate than full and basic care providers (2.8% vs. both 4.0%); results confirmed in our multivariate logistic regression analysis (odds ratio (OR) 1.434, 95% CI 1.127-1.824 and OR 1.459, 95% confidence interval (CI) 1.139-1.870 for full and basic coverage hospitals vs. university hospitals respectively). The proportion of privately insured varied between 16.0% in university hospitals and 38.9% in specialized hospitals. Private insurance had an OR of 1.419 (95% CI 1.306-1.542) in predicting treatment of a hip fracture with primary hip replacement. The seeming importance of insurance type on hip fracture treatment and the large inequity in the distribution of privately insured between provider types would be worth a closer look by the regulatory authorities. Better outcomes, i.e., lower mortality rates for hip fracture treatment in hospitals with a higher structural care level advocate centralization of care.

  19. Clinical Evaluation of the TITAN™ Total Shoulder System

    ClinicalTrials.gov

    2018-02-14

    Arthritis; Arthritis, Degenerative; Rheumatoid Arthritis; Post-traumatic Arthrosis of Other Joints, Shoulder Region; Rotator Cuff Syndrome of Shoulder and Allied Disorders; Fracture; Avascular Necrosis; Joint Instability; Joint Trauma; Dislocation, Shoulder; Pain, Shoulder

  20. Satisfactory clinical outcome following delayed repositioning of a traumatic post-LASIK flap with dislocation and shrinkage managed by irrigation, stretching, and debridement.

    PubMed

    Xu, Ye-Sheng; Xie, Wen-Jia; Yao, Yu-Feng

    2017-06-01

    To report surgical management and favorable outcome in a case with delayed repair of traumatic laser in situ keratomileusis (LASIK) flap dislocation with shrinkage and folds. A 30-year-old man with a five-year history of bilateral LASIK experienced blunt trauma to his right eye followed by decreased vision for 5 weeks. The surgical management included initially softening the flap by irrigation with balanced salt solution (BSS). The shrinkage folds were carefully and gently stretched by scraping with a 26-gauge cannula accompanied by BSS irrigation. All of the epithelial ingrowth on the flap inner surface and on the bed was thoroughly debrided by scraping and irrigation. After the flap was repositioned to match its original margin, a soft bandage contact lens was placed. At his initial visit, slit-lamp microscopy and optical coherence tomography (OCT) showed shrinkage of the LASIK flap with an elevated margin approximately 3 mm above the original position. The flap covered half of the pupil and had multiple horizontal folds. Two months after surgery, the flap remained well positioned with only faint streaks in the anterior stroma. The uncorrected visual acuity of the right eye was 20/20 with a manifest refraction of Plano. For delayed repair of traumatically dislocated LASIK flaps, sufficient softening by BSS, stretching the shrinkage folds, and thorough debridement of ingrowth epithelium enable resetting the flap and provide satisfactory results.

  1. Satisfactory clinical outcome following delayed repositioning of a traumatic post-LASIK flap with dislocation and shrinkage managed by irrigation, stretching, and debridement*

    PubMed Central

    Xu, Ye-sheng; Xie, Wen-jia; Yao, Yu-feng

    2017-01-01

    Objective: To report surgical management and favorable outcome in a case with delayed repair of traumatic laser in situ keratomileusis (LASIK) flap dislocation with shrinkage and folds. Methods: A 30-year-old man with a five-year history of bilateral LASIK experienced blunt trauma to his right eye followed by decreased vision for 5 weeks. The surgical management included initially softening the flap by irrigation with balanced salt solution (BSS). The shrinkage folds were carefully and gently stretched by scraping with a 26-gauge cannula accompanied by BSS irrigation. All of the epithelial ingrowth on the flap inner surface and on the bed was thoroughly debrided by scraping and irrigation. After the flap was repositioned to match its original margin, a soft bandage contact lens was placed. Results: At his initial visit, slit-lamp microscopy and optical coherence tomography (OCT) showed shrinkage of the LASIK flap with an elevated margin approximately 3 mm above the original position. The flap covered half of the pupil and had multiple horizontal folds. Two months after surgery, the flap remained well positioned with only faint streaks in the anterior stroma. The uncorrected visual acuity of the right eye was 20/20 with a manifest refraction of Plano. Conclusions: For delayed repair of traumatically dislocated LASIK flaps, sufficient softening by BSS, stretching the shrinkage folds, and thorough debridement of ingrowth epithelium enable resetting the flap and provide satisfactory results. PMID:28585430

  2. Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation.

    PubMed

    Hamadouche, Moussa; Ropars, Mickael; Rodaix, Camille; Musset, Thierry; Gaucher, François; Biau, David; Courpied, Jean Pierre; Huten, Denis

    2017-03-01

    Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.

  3. Socket position determines hip resurfacing 10-year survivorship.

    PubMed

    Amstutz, Harlan C; Le Duff, Michel J; Johnson, Alicia J

    2012-11-01

    Modern metal-on-metal hip resurfacing arthroplasty designs have been used for over a decade. Risk factors for short-term failure include small component size, large femoral head defects, low body mass index, older age, high level of sporting activity, and component design, and it is established there is a surgeon learning curve. Owing to failures with early surgical techniques, we developed a second-generation technique to address those failures. However, it is unclear whether the techniques affected the long-term risk factors. We (1) determined survivorship for hips implanted with the second-generation cementing technique; (2) identified the risk factors for failure in these patients; and (3) determined the effect of the dominant risk factors on the observed modes of failure. We retrospectively reviewed the first 200 hips (178 patients) implanted using our second-generation surgical technique, which consisted of improvements in cleaning and drying the femoral head before and during cement application. There were 129 men and 49 women. Component orientation and contact patch to rim distance were measured. We recorded the following modes of failure: femoral neck fracture, femoral component loosening, acetabular component loosening, wear, dislocation, and sepsis. The minimum followup was 25 months (mean, 106.5 months; range, 25-138 months). Twelve hips were revised. Kaplan-Meier survivorship was 98.0% at 5 years and 94.3% at 10 years. The only variable associated with revision was acetabular component position. Contact patch to rim distance was lower in hips that dislocated, were revised for wear, or were revised for acetabular loosening. The dominant modes of failure were related to component wear or acetabular component loosening. Acetabular component orientation, a factor within the surgeon's control, determines the long-term success of our current hip resurfacing techniques. Current techniques have changed the modes of failure from aseptic femoral failure to wear or loosening of the acetabular component. Level III, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.

  4. Acute Versus Delayed Magnetic Resonance Imaging and Associated Abnormalities in Traumatic Anterior Shoulder Dislocations

    PubMed Central

    Orvets, Nathan D.; Parisien, Robert L.; Curry, Emily J.; Chung, Justin S.; Eichinger, Josef K.; Murakami, Akira M.; Li, Xinning

    2017-01-01

    Background: The delayed management of patients with shoulder instability may increase the prevalence and severity of concomitant intra-articular shoulder injuries resulting from persistent subluxations and dislocations. Hypothesis: Patients with a longer delay from the initial dislocation event to undergoing magnetic resonance imaging (MRI) or magnetic resonance arthrography will demonstrate more subluxations or dislocations and a greater amount of intra-articular shoulder damage. Study Design: Cohort study; Level of evidence, 3. Methods: We performed a retrospective review of 89 patients from a single institution with clinically and radiographically confirmed primary traumatic anterior shoulder dislocations. Patients were divided into 2 groups: those undergoing MRI less than 6 months (n = 44; LT6) or greater than 6 months (n = 45; GT6) from the initial dislocation event. The MRI assessment included evaluation of soft tissue injuries, including the labrum, capsule, rotator cuff, and cartilage damage severity along with bone loss. Results: The delayed MRI group (GT6) demonstrated a greater degree of intra-articular abnormalities compared to the early MRI group (LT6). A greater percentage of superior labral anterior-posterior (SLAP) tears (58% vs 34%, respectively) and cartilage damage (73% vs 27%, respectively) was present in the GT6 group compared to the LT6 group. Cartilage damage was 18% mild, 7% moderate, and 2% severe for the LT6 group as compared to 38% mild, 31% moderate, and 4% severe for the GT6 group. Additionally, more recurrent shoulder dislocations were seen in the GT6 group (n = 6) compared to the LT6 group (n = 2). In the LT6 group, there were more rotator cuff tears (50% vs 24%, respectively) and capsular tears (25% vs 9%, respectively) than the GT6 group. There was no difference in anterior glenoid bone loss, glenoid version, or humeral head subluxation between the 2 groups. Conclusion: Patients who undergo MRI greater than 6 months from the time of primary or initial shoulder dislocation had significantly more recurrent shoulder instability events and demonstrated a greater incidence and severity of intra-articular abnormalities, including SLAP tears, posterior labral tears, and anterior glenoid cartilage damage. PMID:28975132

  5. Cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy in patients with Crowe type-IV hip dysplasia.

    PubMed

    Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi

    2013-06-01

    The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.

  6. An update on surgical approaches in hip arthoplasty: lateral versus posterior approach.

    PubMed

    Mukka, Sebastian S; Sayed-Noor, Arkan S

    2014-10-02

    In this update we searched the literature about the outcome of the lateral versus posterior approach in hip arthoplasty for osteoarthritis (OA) and femoral neck fracture (FNF) patients. The available evidence shows that the use of posterior approach in OA patients is associated with lower mortality and better functional outcome while the use of lateral approach in FNF patients gives lower dislocation rate. We recommend therefore the use of posterior approach in OA patients and lateral approach in FNF patients.

  7. [Total hip arthroplasty through anterior "minimal invasive" approach].

    PubMed

    Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A

    2012-12-19

    Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.

  8. Management of traumatic patellar dislocation in a regional hospital in Hong Kong.

    PubMed

    Lee, H L; Yau, W P

    2017-04-01

    The role of surgery for acute patellar dislocation without osteochondral fracture is controversial. The aim of this study was to report the short-term results of management of patellar dislocation in our institute. Patients who were seen in our institution with patella dislocation from January 2011 to April 2014 were managed according to a standardised management algorithm. Pretreatment and 1-year post-treatment International Knee Documentation Committee score, Tegner activity level scale score, and presence of apprehension sign were analysed. A total of 41 patients were studied of whom 20 were first-time dislocators and 21 were recurrent dislocators. Among the first-time dislocators, there was a significant difference between patients who received conservative treatment versus surgical management. The conservative treatment group had a 33% recurrent dislocation rate, whereas there were no recurrent dislocations in the surgery group. There was no difference in Tegner activity level scale score or apprehension sign before and 1 year after treatment, however. Among the recurrent dislocators, there was a significant difference between those who received conservative treatment and those who underwent surgery. The recurrent dislocation rate was 71% in the conservative treatment group versus 0% in the surgery group. There was also significant improvement in International Knee Documentation Committee score from 67.7 to 80.0 (P=0.02), and of apprehension sign from 62% to 0% (P<0.01). A management algorithm for patellar dislocation is described. Surgery is preferable to conservative treatment in patients who have recurrent patellar dislocation, and may also be preferable for those who have an acute dislocation.

  9. Complications in Hip Arthroscopy

    PubMed Central

    Nakano, Naoki; Khanduja, Vikas

    2016-01-01

    Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747

  10. Traumatic dislocation of the S1 polyaxial pedicle screw head: a case report.

    PubMed

    Du Plessis, Pieter N B; Lau, Bernard P H; Hey, Hwee Weng Dennis

    2017-03-01

    Polyaxial screw head dislocation in the absence of a manufacture defect is extremely rare and represents a biomechanical overload of the screw, leading to early failure. A 58-year-old gentleman underwent instrumented fusion using polyaxial pedicle screws-titanium rod construct with interbody cage for spondylolytic spondylolisthesis at the L5/S1 level. He attempted to bend forward ten days after the surgery which resulted in a dislocation of the right S1 polyaxial screw head from the screw shank with recurrence of symptoms. He underwent revision surgery uneventfully. This case highlights the need to pay particular attention to the strength of fixation and the amount of release to avoid such a complication.

  11. Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor.

    PubMed

    Lombardi, Adolph V; Berend, Keith R; Morris, Michael J; Adams, Joanne B; Sneller, Michael A

    2015-02-01

    Use of large-diameter metal-on-metal (MoM) articulations in THA increased, at least in part, because of the possibility of achieving improved joint stability and excellent wear characteristics in vitro. However, there have been subsequent concerning reports with adverse reactions to metal debris (ARMD), pseudotumors, and systemic complications related to metal ions. The purpose of this study was to determine at a minimum of 2 years' followup (1) the proportion of patients who experienced a dislocation; (2) the short-term survivorship obtained with these implants; (3) the causes of failure and the proportion of patients who developed ARMD; and (4) whether there were any identifiable risk factors for revision. We reviewed the results of 1235 patients who underwent 1440 large-diameter MoM primary THAs at our institution using two acetabular devices from a single manufacturer with minimum 2-year followup. Large-diameter MoM devices were used in 48% (1695 of 3567) of primary THAs during the study period. We generally used these implants in younger, more active, higher-demand patients, in patients considered at higher risk of instability, and in patients with adequate bone stock to achieve stable fixation without use of screws. Clinical records and radiographs were reviewed to determine the incidence and etiology of revision. Patients whose hips were revised were compared with those not revised to identify risk factors; Kaplan-Meier survivorship analysis was performed as was multivariate analysis to account for potential confounding variables when evaluating risk factors. Minimum followup was 2 years (average, 7 years; range, 2-12 years); complete followup was available in 85% of hips (1440 of 1695). Dislocation occurred in one hip overall (<1%; one of 1440). Kaplan-Meier analysis revealed survival free of component revision was 87% at 12 years (95% confidence interval, 84%-90%). The two most common indications for revision were ARMD (48%; 47 of 108 hips revised) and loosening or failure of ingrowth (31%; 34 of 108). Risk factors for component revision were younger age at surgery (relative risk [RR] 0.98 per each increased year; p=0.02), higher cup angle of inclination (RR 1.03 per each increased degree; p=0.04), and female sex (RR 1.67; p=0.03). Large-diameter MoM THAs are associated with a very low dislocation rate, but failure secondary to ARMD and loosening or lack of ingrowth occur frequently. Patients with MoM THA should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Early diagnosis and appropriate treatment are recommended to prevent the damaging effects of advanced ARMD. Level IV, Therapeutic study.

  12. Internet search term affects the quality and accuracy of online information about developmental hip dysplasia.

    PubMed

    Fabricant, Peter D; Dy, Christopher J; Patel, Ronak M; Blanco, John S; Doyle, Shevaun M

    2013-06-01

    The recent emphasis on shared decision-making has increased the role of the Internet as a readily accessible medical reference source for patients and families. However, the lack of professional review creates concern over the quality, accuracy, and readability of medical information available to patients on the Internet. Three Internet search engines (Google, Yahoo, and Bing) were evaluated prospectively using 3 difference search terms of varying sophistication ("congenital hip dislocation," "developmental dysplasia of the hip," and "hip dysplasia in children"). Sixty-three unique Web sites were evaluated by each of 3 surgeons (2 fellowship-trained pediatric orthopaedic attendings and 1 orthopaedic chief resident) for quality and accuracy using a set of scoring criteria based on the AAOS/POSNA patient education Web site. The readability (literacy grade level) of each Web site was assessed using the Fleisch-Kincaid score. There were significant differences noted in quality, accuracy, and readability of information depending on the search term used. The search term "developmental dysplasia of the hip" provided higher quality and accuracy compared with the search term "congenital hip dislocation." Of the 63 total Web sites, 1 (1.6%) was below the sixth grade reading level recommended by the NIH for health education materials and 8 (12.7%) Web sites were below the average American reading level (eighth grade). The quality and accuracy of information available on the Internet regarding developmental hip dysplasia significantly varied with the search term used. Patients seeking information about DDH on the Internet may not understand the materials found because nearly all of the Web sites are written at a level above that recommended for publically distributed health information. Physicians should advise their patients to search for information using the term "developmental dysplasia of the hip" or, better yet, should refer patients to Web sites that they have personally reviewed for content and clarity. Orthopaedic surgeons, professional societies, and search engines should undertake efforts to ensure that patients have access to information about DDH that is both accurate and easily understandable.

  13. HEMIARTHROPLASTY IN THE TREATMENT FRACTURES OF THE FEMORAL NECK

    PubMed Central

    Ono, Nelson Keiske; de Andrade Lima, Guilherme Didier; Honda, Emerson Kiyoshi; Polesello, Giancarlo Cavalli; Guimarães, Rodrigo Pereira; Júnior, Walter Ricioli; de Queiroz, Marcelo Cavalheiro

    2015-01-01

    Objective: To epidemiologically and clinically evaluate patients with displaced femoral neck fractures that were surgically treatment with cemented hip hemiarthroplasty. Methods: All patients with displaced femoral neck fractures (Garden III and IV) who underwent cemented hip hemiarthroplasty using a unipolar prosthesis (Thompson), by means of a posterolateral access between June 2005 and September 2008 were retrospectively evaluated. Results: Seventy patients were initially evaluated. Their mean age was 83.1 years. The patients were predominantly female (84.3%). Thirty-six patients were monitored as outpatients for periods ranging from 10 to 48 months (mean of 26.5 months). Fifteen patients were lost to follow-up. Nineteen patients died, and the mortality rate within the first year was 25.4%. Patients classified as ASA III had a mortality rate of 25.7% and ASA II patients, a rate of 12.1%. Two patients had symptomatic deep vein thrombosis; one patient had an operative wound infection; and none of the patients presented hip dislocation. Most of the patients did not experience pain. Twelve patients (33%) showed deterioration of their walking ability. Conclusion: There were no cases of hip dislocation. Patients classified as ASA III had a higher mortality rate than did patients with ASA I or II. There was a worsening of walking ability in 33% of the patients. No revision due to loosening or pain was needed for any patient. Thirty patients did not present any pain (83.3%), four presented moderate pain (11.1%) and two presented intense pain (5.5%). PMID:27022567

  14. Hip lateralisation in children with bilateral spastic cerebral palsy treated with botulinum toxin type A: a 2-year follow-up.

    PubMed

    Jung, N H; Heinen, F; Westhoff, B; Doederlein, L; Reissig, A; Berweck, S; Linder-Lucht, M; Schandelmaier, S; Mall, V

    2011-02-01

    We investigated the effect of BoNT/A injection on hip lateralisation in children with bilateral spastic cerebral palsy and bilateral adductor spasticity. Pelvic radiographs using Reimers' migration index (MI) were evaluated from 27 children (n=9 females, n=18 males; mean age 5.2 ± 1.96 years; range: 2-10 years; initial MI <50%) with bilateral spastic cerebral palsy over a time period of 2 years. All received injections of BoNT/A (Dysport) every 12 weeks with a dose of 30 Units per kilogram body weight into adductor and medial hamstring muscles on both sides. The MI was calculated before treatment and after 1 and 2 years. The mean MI increased from 25.5% (range: 0-48) to 26.7% (+1.2%, range: 0-79) on the right side and from 28.0% (range: 0-40) to 30.6% (+2.6%, range: 3-84) on the left side over 2 years, respectively. Hips of one patient dislocated bilaterally. The mean MI remained stable over 2 years. Although a specific BoNT/A effect cannot be proven because of the open design of this study, we provide strong evidence that the MI can be kept stable for a time period of 2 years under non-surgical management including therapy with BoNT/A even in CP patients with a high risk for hip dislocation. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Delayed management of traumatic bilateral cervical facet dislocation: surgical strategy. Report of three cases.

    PubMed

    Bartels, Ronald H M A; Donk, Roland

    2002-10-01

    Postinjury cervical spine instability typically requires surgical treatment in the acute or semiacute stage. The authors, however, report on three patients with older (> 8 weeks) untreated bilateral cervical facet dislocation. In two patients they attempted a classic anterior-posterior-anterior approach but failed. The misalignment in the second stage of the procedure could not be corrected, and they had to add a fourth, posterior, stage. To avoid the fourth stage, thereby reducing operating time and risk of neurological damage while turning the patient, they propose the following sequence: 1) a posterior approach to perform a complete facetectomy bilaterally with no attempt to reduce the dislocation; 2) an anterior microscopic discectomy with reduction of the dislocation and anterior fixation; and 3) posterior fixation. This sequence of procedures was successfully performed in the third patient. Based on this experience, they suggest that in cases of nonacute bilateral cervical facet dislocations the operating sequence should be posterior-anterior-posterior.

  16. Traumatic inferior shoulder dislocation: a review of management and outcome.

    PubMed

    Nambiar, Mithun; Owen, David; Moore, Peter; Carr, Ashley; Thomas, Malcolm

    2018-02-01

    Traumatic inferior shoulder dislocation (ISD) is rare, estimated to occur in 0.5% of all shoulder dislocations. We describe the demographics, natural history and outcome of this injury. The aim of the study is to provide a summary of the demographics, clinical presentation, management and outcome of patients who suffer ISD METHODS: We conducted a systematic review of the English language literature on ISD using PubMed, Medline, CINHAL, Cochrane Database and Evidence-Based Medicine Reviews. Articles were examined independently by two of the authors and data were extracted using a standard form. Descriptive statistics were performed. 199 patients were identified, from 101 articles. Mean age was 44 years (range 13-94 years). All cases were caused by trauma, with falls accounting for 44% of all cases. There were three reported cases (2%) of open dislocations and 29 cases (15%) of bilateral ISD. Proximal humerus and scapular fractures were reported in 39 and 8% of patients, respectively. Neurological injury after dislocation was noted in 58 patients (29%). Vascular injury was noted in 20 patients (10%), which included axillary arterial injury in 19 patients and an upper limb deep vein thrombosis in one patient. Follow-up data were available for 107 patients (54%), with an average duration of 2.7 years (1 week-32 years). Avascular necrosis (AVN) was noted between 8 weeks and 2 years after initial injury in three patients (1.5%). Clinical and radiographic assessment of ISD is key to diagnosis and successful reduction. Patients can be treated with shoulder immobilisation for 2-3 weeks. In the setting of ongoing pain or instability, further imaging should be performed. The outcome of ISD is generally favourable.

  17. Dynamic long leg casting fixation for treating 12- to 18-month-old infants with developmental dysplasia of the hip.

    PubMed

    Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun

    2017-02-01

    Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.

  18. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    PubMed

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  19. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    PubMed

    Banks, Louisa N; McElwain, John P

    2010-04-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  20. Childhood cerebral palsy and the use of positioning systems to control body posture: Current practices.

    PubMed

    Pérez-de la Cruz, S

    One of the consequences of poor postural control in children with cerebral palsy is hip dislocation. This is due to the lack of weight-bearing in the sitting and standing positions. Orthotic aids can be used to prevent onset and/or progression. The aim of this study is to analyse the effectiveness of positioning systems in achieving postural control in patients with cerebral palsy, and discuss these findings with an emphasis on what may be of interest in the field of neurology. We selected a total of 18 articles on interventions in cerebral palsy addressing posture and maintenance of ideal postures to prevent deformities and related problems. The main therapeutic approaches employed combinations of botulinum toxin and orthoses, which reduced the incidence of hip dislocation although these results were not significant. On the other hand, using positioning systems in 3 different positions decreases use of botulinum toxin and surgery in children under 5 years old. The drawback is that these systems are very uncomfortable. Postural control systems helps control hip deformities in children with cerebral palsy. However, these systems must be used for prolonged periods of time before their effects can be observed. Copyright © 2015 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. The three-pin modified 'Harrington' procedure for advanced metastatic destruction of the acetabulum.

    PubMed

    Tillman, R M; Myers, G J C; Abudu, A T; Carter, S R; Grimer, R J

    2008-01-01

    Pathological fractures due to metastasis with destruction of the acetabulum and central dislocation of the hip present a difficult surgical challenge. We describe a series using a single technique in which a stable and long-lasting reconstruction was obtained using standard primary hip replacement implants augmented by strong, fully-threaded steel rods with cement and steel mesh, where required. Between 1997 and 2006, 19 patients with a mean age of 66 years (48 to 83) were treated using a modified Harrington technique. Acetabular destruction was graded as Harrington class II in six cases and class III in 13. Reconstruction was achieved using three 6.5 mm rods inserted through a separate incision in the iliac crest followed by augmentation with cement and a conventional cemented Charnley or Exeter primary hip replacement. There were no peri-operative deaths. At the final follow-up (mean 25 months (5 to 110)) one rod had fractured and one construct required revision. Of the 18 patients who did not require revision, 13 had died. The mean time to death was 16 months (5 to 55). The mean follow-up of the five survivors was 31 months (18 to 47). There were no cases of dislocation, deep infection or injury to a nerve, the blood vessels or the bladder.

  2. Inhalant abuse of 1,1-difluoroethane (DFE) leading to heterotopic ossification: a case report

    PubMed Central

    Little, Jill; Hileman, Barbara; Ziran, Bruce H

    2008-01-01

    Background Heterotopic ossification (HO) is the formation of mature, lamellar bone within soft tissues other than the periosteum. There are three recognized etiologies of HO: traumatic, neurogenic, and genetic. Presently, there are no definitively documented causal factors of HO. The following factors are presumed to place a patient at higher risk: 60 years of age or older, male, previous HO, hypertrophic osteoarthritis, ankylosing spondylitis, diffuse idiopathic skeletal hyperostosis, prior hip surgery, and surgical risk factors. Case presentation A 33-year-old male, involved in a motor vehicle crash, sustained an irreducible acetabulum fracture/dislocation, displaced proximal humerus fracture, and an impacted pilon fracture. During the time of injury, he was intoxicated from inhaling the aerosol propellant used in "dust spray" cans (1,1-difluoroethane, C2H4F2). Radiographs identified rapid pathologic bone formation about the proximal humeral metaphysis, proximal femur, elbow, and soft tissue several months following the initial injury. Discussion The patient did not have any genetic disorders that could have attributed to the bone formation but had some risk factors (male, fracture with dislocation). Surgically, the recommended precautions were followed to decrease the chance of HO. Although the patient did not have neurogenic injuries, the difluoroethane in dusting spray can cause damage to the central nervous system. Signals may have been mixed causing the patient's body to produce bone instead of tissue to strengthen the injured area. Conclusion What is unusual in this case is the rate at which the pathological bone formation appeared, which was long outside the 4–6 week window in which HO starts to appear. The authors are not certain as to the cause of this rapid formation but suspect that the patient's continued abuse of inhaled aerosol propellants may be the culprit. PMID:18973696

  3. Inhalant abuse of 1,1-difluoroethane (DFE) leading to heterotopic ossification: a case report.

    PubMed

    Little, Jill; Hileman, Barbara; Ziran, Bruce H

    2008-10-30

    Heterotopic ossification (HO) is the formation of mature, lamellar bone within soft tissues other than the periosteum. There are three recognized etiologies of HO: traumatic, neurogenic, and genetic. Presently, there are no definitively documented causal factors of HO. The following factors are presumed to place a patient at higher risk: 60 years of age or older, male, previous HO, hypertrophic osteoarthritis, ankylosing spondylitis, diffuse idiopathic skeletal hyperostosis, prior hip surgery, and surgical risk factors. A 33-year-old male, involved in a motor vehicle crash, sustained an irreducible acetabulum fracture/dislocation, displaced proximal humerus fracture, and an impacted pilon fracture. During the time of injury, he was intoxicated from inhaling the aerosol propellant used in "dust spray" cans (1,1-difluoroethane, C2H4F2). Radiographs identified rapid pathologic bone formation about the proximal humeral metaphysis, proximal femur, elbow, and soft tissue several months following the initial injury. The patient did not have any genetic disorders that could have attributed to the bone formation but had some risk factors (male, fracture with dislocation). Surgically, the recommended precautions were followed to decrease the chance of HO. Although the patient did not have neurogenic injuries, the difluoroethane in dusting spray can cause damage to the central nervous system. Signals may have been mixed causing the patient's body to produce bone instead of tissue to strengthen the injured area. What is unusual in this case is the rate at which the pathological bone formation appeared, which was long outside the 4-6 week window in which HO starts to appear. The authors are not certain as to the cause of this rapid formation but suspect that the patient's continued abuse of inhaled aerosol propellants may be the culprit.

  4. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    PubMed

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing"femur first"principle and combined anteversion techniqueis was (36.6±6.8)°. Also, range of motion of the patients' hip conforms to the D'Lima criterion and no patients had experienced dislocation and some other serious complications.The follow-up ended at August 2017, which lasted for 12.2 months(6-18 months), and 88 cases(119 hips) were interviewed. The Harris hip score for the affected sides of the hip joints 6 months after the surgery was 94.6(86-100). Compared with the score of 29.8(12-43) before surgery, the t -test had proven its statistical significance( t =12.82, P =0.003). Conclusion: Based upon the "femoral first" principle and "combined anteversion technique" during total hip arthroplasty, these operations has been carried out well enough to meet the patients' needs of performing normal daily activities.

  5. Bipolar femoral head arthroplasty in osteoarthritis. A prospective study with a minimum 5-year follow-up period.

    PubMed

    Pandit, R

    1996-08-01

    Primary bipolar femoral head arthroplasties performed on 100 osteoarthritic hips were studied to a minimum of 5 years after surgery. All arthroplasties were performed on physically active patients. At a mean follow-up period of 5.5 years, The Hospital for Special Surgery hip scores were good to excellent in 96 hips. Transient startup soreness constituted the most frequent complaint, occurring in 34 hips. Three hips had more persistent pain localized to the acetabulum, necessitating revision to fixed sockets, which alleviated the symptoms. Four additional hips, in heavy, active men, developed polyethylene fatigue fracture and component disassembly. Acetabular migration of more than 5 mm developed in one hip. Motion, as determined radiologically, occurred primarily at the inner bearing. There were no dislocations or infections in the series. The Bateman bipolar prosthesis provides generally good results in osteoarthritic hips. The shorter operating time and the case of revision are special advantages of bipolar devices. Start-up soreness and stiffness is a shortcoming in approximately one third of cases. Component disassembly in heavy, active men is a problem and the bipolar arthroplasty should be avoided in these patients. Start-up soreness was a significant problem in particular.

  6. Outcome after cementless total hip arthroplasty for arthritic hip in patients with residual poliomyelitis: a case series.

    PubMed

    Cho, Yoon J; Lee, Choong H; Chun, Young S; Rhyu, Kee H

    2016-09-29

    In this case series, we investigated the outcome of cementless total hip arthroplasty (THA) for advanced hip osteoarthritis in patients with residual poliomyelitis to evaluate its clinical usefulness for these patients. 11 unilateral cementless primary THA were performed to arthritic hips in patients with residual poliomyelitis. 7 were in paralytic and 4 were in nonparalytic limbs. The mean follow-up duration was 79.9 months. Retrospective clinical evaluations with various scores and radiological evaluations were made. Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Short-form (SF)-36 physical scales were significantly improved after the surgery. However, UCLA activity score and SF-36 mental scale were not. Because of remaining leg length discrepancies, all but 1 noted a residual limp. In nonparalytic hip, functional acetabular cup inclination during weight bearing significantly increased from installed inclination. Other than 1 case of posterior dislocation, no complications were observed. Although the overall result itself is excellent, THA for these patients cannot improve limp, physical activity and mental status. Surgeons should be aware of the change of the inclination of acetabular cup during mobilisation, especially for THA in contralateral hip.

  7. Hip health at skeletal maturity: a population-based study of young adults with cerebral palsy.

    PubMed

    Wawrzuta, Joanna; Willoughby, Kate L; Molesworth, Charlotte; Ang, Soon Ghee; Shore, Benjamin J; Thomason, Pam; Graham, H Kerr

    2016-12-01

    We studied 'hip health' in a population-based cohort of adolescents and young adults with cerebral palsy to investigate associations between hip morphology, pain, and gross motor function. Ninety-eight young adults (65 males, 33 females) from the birth cohort were identified as having developed hip displacement (migration percentage >30) and were reviewed at a mean age of 18 years 10 months (range 15-24y). Hip morphology was classified using the Melbourne Cerebral Palsy Hip Classification Scale (MCPHCS). Severity and frequency of pain were recorded using Likert scales. Gross motor function was classified by the Gross Motor Function Classification System (GMFCS). Hip pain was reported in 72% of participants. Associations were found between pain scores and both hip morphology and GMFCS. Median pain severity score for MCPHCS grades 1 to 4 was 2 (interquartile range [IQR] 1.0-3.0) compared to 7 (IQR 6.0-8.0) for grades 5 and 6 (severe subluxation or dislocation). Hip surveillance and access to surgery were associated with improved hip morphology and less pain. Poor hip morphology at skeletal maturity was associated with high levels of pain. Limited hip surveillance and access to surgery, rather than GMFCS, was associated with poor hip morphology. The majority of young adults who had access to hip surveillance, and preventive and reconstructive surgery, had satisfactory hip morphology at skeletal maturity and less pain. © 2016 Mac Keith Press.

  8. Management of non-traumatic avascular necrosis of the femoral head-a comparative analysis of the outcome of multiple small diameter drilling and core decompression with fibular grafting.

    PubMed

    Mohanty, S P; Singh, K A; Kundangar, R; Shankar, V

    2017-04-01

    The purpose of this study was to compare the clinical and radiological outcomes of multiple small diameter drilling and core decompression with fibular strut grafting in the management of non-traumatic avascular necrosis (AVN) of the femoral head. Outcomes of patients with AVN treated by multiple small diameter drilling (group 1) were compared retrospectively with patients treated by core decompression and fibular grafting (group 2). Harris hip score (HHS) was used to assess the clinical status pre- and postoperatively. Modified Ficat and Arlet classification was used to assess the radiological stage pre- and postoperatively. Forty-six patients (68 hips) were included in this study. Group 1 consisted of 33 hips, and group 2 consisted of 35 hips. In stages I and IIB, there was no statistically significant difference in the final HHS between the two groups. However, in stages IIA and III, hips in group 2 had a better final HHS (P < 0.05). In terms of radiographic progression, there was no statistical difference between hips in stages I, IIA and stage IIB. However, in stage III, hips belonging to group 2 had better results (P < 0.05). Kaplan-Meier survivorship analysis showed better outcome in group 2 in stage III (P < 0.05). Hips with AVN in the precollapse stage can be salvaged by core decompression with or without fibular grafting. Multiple small diameter drilling is relatively simple and carries less morbidity and hence preferred in stages I and II. However, in stage III disease, core decompression with fibular strut grafting gives better results.

  9. Gender differences influence the outcome of geriatric rehabilitation following hip fracture.

    PubMed

    Arinzon, Zeev; Shabat, Shay; Peisakh, Alexander; Gepstein, Reuven; Berner, Yitshal N

    2010-01-01

    Hip fracture represents the most dramatic expression of the disease, in terms of morbidity, medical cost and mortality. The incidence of hip fracture increases substantially with age. The purpose of this study was to evaluate the association between gender and geriatric rehabilitation outcome after traumatic hip fracture. Ninety-nine community-dwelling elderly patients (older than 65 years), 64 women and 35 men, who were admitted to geriatric rehabilitation after operated hip fracture were studied. We assessed the patients' clinical and demographic data, preoperative risk (ASA), type of fracture and orthopedic repair, pain intensity (VAS), cognitive (MMSE), mood (Zung IDS), and functional status (FIM) on admission and at the end of geriatric rehabilitation. Men had higher mean number of comorbid conditions at the time of the fracture. Men recovered more from depressed mood in comparison with women during the rehabilitation. Significant improvement in FIM motor subscore on discharge was found in both groups. The FIM motor subscore gain was higher in men (24.47) in comparison with women (19.22, p=0.036). Those differences were demonstrated in mean subscores of transfers (p=0.004), and locomotion (p=0.019). Women were more functionally dependent in locomotion, transfers and sphincter control. There were no differences between the groups by duration on rehabilitation stay. Recovery after hip fracture depends in large part on the pre-fracture health and functional ability of the patient. Gender differences in functional recovery may affect therapeutic and rehabilitative decision making. Functional recovery after traumatic hip fracture was better in men in comparison with women.

  10. [APPLICATION AND EFFECTIVENESS OF BIOLOGICAL TYPE ACETABULAR CUP IN ADULT Crowe TYPE IV DEVELOPMENTAL DYSPLASIA OF THE HIP].

    PubMed

    Xu, Ning; Sun, Junying; Zhao, Xijiang; Wang, Tao

    2016-01-01

    To investigate the application and effectiveness of the biological type acetabular cup(diameter < 44 mm) in adult Crowe type IV developmental dysplasia of the hip (DDH). Between April 2001 andAugust 2013, biological type acetabular cup was used in total hip arthroplasty for the treatment of Crowe type IV DDH in16 cases (20 hips). There were 3 males and 13 females, aged 31-69 years (mean, 49 years). Unilateral hip was involved in 12cases, and bilateral hips in 4 cases. The patients showed pain of the hip joint and inequality of lower limb (shortening ofaffected limb 1.8-6.0 cm in length, 3.5 cm on average). Acetabular deformity, the relationship and the severity of femoralhead dislocation were comfirmed on the X-ray films. The preoperative Harris score was 34.0 ± 6.9. All patientsachieved healing of incision by first intention, with no complication of infection or neurovascular injury. Sixteen caseswere followed up 4-12 years (mean, 7.5 years). At 2 weeks after operation, dislocation occurred in 2 cases, and were fixedwith plaster for 3 weeks after reduction of the hip. Postoperative X-ray films showed complete reduction of femoral head;the average acetabular coverage of the cup of the weight-bearing area was 98.5% (range, 98.2%-99.1%). The cup from theRanawat triangle was 4.6-7.0 mm (mean, 5.8 mm) in medial shifting, and was 4.5-7.9 mm (mean, 6.2 mm) in elevation,it located at cup lateral surface area inside the iliopectineal line and the Kohler line (< 40%); the cup abduction angle was(45 ± 5)degrees, and the anteversion angle was (10 ± 5)degrees. The other patients had no prosthesis loosening except 1 patient havingextensive acetabular prosthesis loosening because of acetabular osteolysis at 12 years after operation. The hip Harris scorewas significantly improved to 85.0 ± 7.5 at 1 year after operation (t = 14.34, P = 0.01). The acetabular grindingprocess to retain enough bone combined with a small cup of-biological prosthesis treating adult Crowe type IV DDH has theadvantages of satisfactory coverage and initial acetabular fixation, so good early and mid-term effectiveness can be obtained.

  11. Traumatic dislocation of the S1 polyaxial pedicle screw head: a case report

    PubMed Central

    Du Plessis, Pieter N. B.; Lau, Bernard P. H.

    2017-01-01

    Polyaxial screw head dislocation in the absence of a manufacture defect is extremely rare and represents a biomechanical overload of the screw, leading to early failure. A 58-year-old gentleman underwent instrumented fusion using polyaxial pedicle screws-titanium rod construct with interbody cage for spondylolytic spondylolisthesis at the L5/S1 level. He attempted to bend forward ten days after the surgery which resulted in a dislocation of the right S1 polyaxial screw head from the screw shank with recurrence of symptoms. He underwent revision surgery uneventfully. This case highlights the need to pay particular attention to the strength of fixation and the amount of release to avoid such a complication. PMID:28435927

  12. Normal pedal pulses in a popliteal artery thrombosis after a trampoline-associated knee dislocation: a case report.

    PubMed

    Harb, Z; Harb, A; Kammoona, Ishan; Huber, C

    2011-04-01

    In lower extremity trauma, it is routine to check the neurovascular status of the affected limb. Failure to recognise a vascular injury can have catastrophic consequences for the patient. The frequent observation of the distal pulses at regular intervals after a traumatic knee dislocation is absolutely mandatory for the early recognition and management of popliteal artery thrombosis. A limb-threatening complication of popliteal artery thrombosis occurring in association with a palpable dorsalis pedis pulse after a trampoline-related knee dislocation is reported here to emphasise some important teaching points. These lessons are a learning tool to help in the early recognition of the potential complications associated with such injuries and thus minimise their occurrence.

  13. Clinical and radiological outcomes with the Durom™ acetabular cup for large-diameter total hip arthroplasty: 177 implants after a mean of 80 months.

    PubMed

    Saragaglia, D; Belvisi, B; Rubens-Duval, B; Pailhé, R; Rouchy, R C; Mader, R

    2015-06-01

    Large-diameter metal-on-metal hip prostheses are no longer used, but their outcomes after more than 5 years are unknown. We conducted a retrospective study with a 6.8-year mean follow-up to assess clinical outcomes after Durom™ cup implantation, including the dislocation rate, comparatively to the reference metal-on-polyethylene bearing. We determined the rate of failure ascribable to Durom™ cup use. We also looked for a sharp drop in the implant survival curve during the follow-up period and for factors associated with adverse reactions to metal debris (ARMDs). We hypothesised that clinical outcomes after Durom™ cup implantation were similar to those seen with a metal-on-polyethylene bearing, except for a lower rate of dislocation. We included 177 consecutive THA procedures that were performed between 2005 and 2008 in 165 patients with a mean age of 57.6 ± 9.4 years (range, 31-76 years) and involved the implantation of a Durom™ cup, a femoral head greater than 36mm in diameter, and a PF(®) femoral stem (Zimmer, Etupes, France). The mini-posterior approach was used, with 2mm of acetabular overreaming in 82% of cases, a short femoral neck in 75% of cases, and a mean cup inclination of 34 ± 5° (range, 21-50°). Outcomes were assessed for 156 THA procedures in 146 patients after a mean follow-up of 6 years 8 months. The mean Postel-Merle d'Aubigné score improved from 9.7 ± 2.7 (range, 4-14) to 17.4 ± 1.7 (range, 15-18) and the mean Harris hip score from 45.2 ± 15.3 (range, 9-83) to 96.3 ± 7 (75-100). No episodes of dislocation were recorded. We identified 7 failures ascribable to the Durom™ cup including 6 due to ARMD and 1 to aseptic loosening. Implant survival after a mean of 80months was 95.5% (95% CI, 93.1-99.2), with no sharp drop in the survival curve. The Durom™ cup eliminates the risk of hip dislocation and produces similar functional outcomes to those seen with metal-on-polyethylene bearings after a mean follow-up of 80 months. Nevertheless, given the difficulty in predicting ARMD and hypersensitivity reactions, the Durom™ cup has been discarded and patients carrying it are monitored closely. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement.

    PubMed

    Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph

    2017-07-05

    Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the "ball" is located on the acetabular side and the "socket" is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation.

  15. Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement

    PubMed Central

    Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph

    2017-01-01

    Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the “ball” is located on the acetabular side and the “socket” is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation. PMID:28773112

  16. Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty?

    PubMed

    Viste, A; Chouteau, J; Testa, R; Chèze, L; Fessy, M-H; Moyen, B

    2011-05-01

    Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL). TAL is a patient-specific anatomical landmark and a tool for cup orientation. Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used. Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, -8° to +13.3°), 3° (range, -12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively. To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek's safe zone, and functional orientation of the implants. Lewinnek's safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  17. Modern dual-mobility cup implanted with an uncemented stem: about 100 cases with 12-year follow-up.

    PubMed

    Philippot, Remi; Meucci, Jean Francois; Boyer, Bertrand; Farizon, Frederic

    2013-09-01

    We report the results of a 12-year follow-up retrospective series of 100 total hip arthroplasties using cementless, press-fit, dual-mobility acetabular cups. The aim of our study was to evaluate the clinical and radiographic results of this acetabular cup at last follow-up. This continuous and homogeneous series included 100 primary total hip arthroplasties performed during the year 2000. The THA combined a Corail® stem (Corail®, Depuy, Warsaw, IN) with a stainless steel Novae Sunfit® (Serf, Decines, France) acetabular cup. Fifteen patients died and 2 were lost to follow-up. Two cases of early dislocation were observed, and 3 cases of aseptic loosening of the acetabular component were reported. The mean stem subsidence was 0.71 mm, the mean craniopodal acetabular migration was 1.37 mm, and the mean medio-lateral acetabular migration was 1.52 mm. The 12-year survivorship is comparable to the data from the literature. The low dislocation rate at 12 years confirms the long-term, high stability of dual mobility, which should be recommended in primary THA for patients at risk for postoperative instability. The absence of true intraprosthetic dislocation events at 12-year follow-up provides evidence of the good quality of the latest generation of polyethylene liners and the necessity of combining thin-mirror, polished femoral necks with dual-mobility cups.

  18. Acetabular-epiphyseal angle and hip dislocation in cerebral palsy: a preliminary study.

    PubMed

    Alí-Morell, O J; Zurita-Ortega, F; Davó-Jiménez, I; Segura-Biedma, S

    To relate, in non-ambulatory subjects with palsy, Reimers' migration percentage with standardized radiological measurements, including the acetabular-epiphyseal angle. Descriptive, observational and transversal study of 15 individuals with cerebral palsy at levels IV and V of the Gross Motor Function Classification System, aged between 3 and 9 years. Radiological measurements of the acetabular index, Hilgenreiner's epiphyseal angle, acetabular-epiphyseal angle, neck-shaft angle and Reimers' migration percentage of each of the hips were performed. Correlations between acetabular index, epiphyseal angle and acetabular-epiphyseal angle were obtained with respect to the Reimers migration percentage. For hips with a migration rate of 15% or less, a positive correlation was observed between acetabular and epiphyseal angles. In our population, the measurement between acetabular and epiphyseal inclination represents the highest association with the hip migration percentage. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application.

    PubMed

    Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D

    2017-09-01

    Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in the exclusion of these fractures. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on March 17, 2017.

  20. There Is a Significant Discrepancy Between "Big Data" Database and Original Research Publications on Hip Arthroscopy Outcomes: A Systematic Review.

    PubMed

    Sochacki, Kyle R; Jack, Robert A; Safran, Marc R; Nho, Shane J; Harris, Joshua D

    2018-06-01

    The purpose of this study was to compare (1) major complication, (2) revision, and (3) conversion to arthroplasty rates following hip arthroscopy between database studies and original research peer-reviewed publications. A systematic review was performed using PRISMA guidelines. PubMed, SCOPUS, SportDiscus, and Cochrane Central Register of Controlled Trials were searched for studies that investigated major complication (dislocation, femoral neck fracture, avascular necrosis, fluid extravasation, septic arthritis, death), revision, and hip arthroplasty conversion rates following hip arthroscopy. Major complication, revision, and conversion to hip arthroplasty rates were compared between original research (single- or multicenter therapeutic studies) and database (insurance database using ICD-9/10 and/or current procedural terminology coding terminology) publishing studies. Two hundred seven studies (201 original research publications [15,780 subjects; 54% female] and 6 database studies [20,825 subjects; 60% female]) were analyzed (mean age, 38.2 ± 11.6 years old; mean follow-up, 2.7 ± 2.9 years). The database studies had a significantly higher age (40.6 + 2.8 vs 35.4 ± 11.6), body mass index (27.4 ± 5.6 vs 24.9 ± 3.1), percentage of females (60.1% vs 53.8%), and longer follow-up (3.1 ± 1.6 vs 2.7 ± 3.0) compared with original research (P < .0001 for all). Ninety-seven (0.6%) major complications occurred in the individual studies, and 95 (0.8%) major complications occurred in the database studies (P = .029; relative risk [RR], 1.3). There was a significantly higher rate of femoral neck fracture (0.24% vs 0.03%; P < .0001; RR, 8.0), and hip dislocation (0.17% vs 0.06%; P = .023; RR, 2.2) in the database studies. Reoperations occurred at a significantly higher rate in the database studies (11.1% vs 7.3%; P < .001; RR, 1.5). There was a significantly higher rate of conversion to arthroplasty in the database studies (8.0% vs 3.7%; P < .001; RR, 2.2). Database studies report significantly increased major complication, revision, and conversion to hip arthroplasty rates compared with original research investigations of hip arthroscopy outcomes. Level IV, systematic review of Level I-IV studies. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Arthroscopic Triple Labral Repair in an Adolescent.

    PubMed

    Cotter, Eric J; Frank, Rachel M; Trenhaile, Scott W

    2017-10-01

    Traumatic glenohumeral dislocations often result in significant injury to the anterior-inferior labrum, most commonly leading to recurrent anterior instability. While in skeletally immature patients, shoulder trauma more commonly results in fracture versus a true dislocation, shoulder instability does occur and can be difficult to manage in the setting of open physes. In any event, the goal of treatment is to reduce the risk of recurrence and allow full participation in activities, including sports. Arthroscopic stabilization has been shown to be an effective treatment option for young patients, with good return to sport rates; however, the vast majority of literature on shoulder instability in the youth patient population focuses on anterior instability. Concomitant lesions of the anterior, posterior, and superior labrum have been rarely described in youth athletes and present a formidable clinical challenge, particularly in skeletally immature patients. In this Technical Note, we describe the authors' preferred technique for arthroscopic repair of a traumatic triple labral tear, including anterior, posterior, and type IV SLAP components, in adolescent patients.

  2. Experiment K-314: Fetal and neonatal rat bone and joint development following in Utero spaceflight

    NASA Technical Reports Server (NTRS)

    Sabelman, E. E.; Holton, E. M.; Arnaud, C. D.

    1981-01-01

    Infant rat limb specimens from Soviet and U.S. ground-based studies were examined by radiography, macrophotography, histologic sectioning and staining and scanning electron microscopy. A comparison was conducted between vivarium and flight-type diets suggesting that nutritional obesity may adversely affect pregnancy. Data were obtained on maturation of ossification centers, orientation of collagen fibers in bone, tendon and ligaments, joint surface texture and spatial relationships of bones of the hind limb. Computer reconstructions of the knee and hip show promise as a means of investigating the etiology of congenital hip dislocation.

  3. Incidence of and risk factors for traumatic anterior shoulder dislocation: an epidemiologic study in high-school rugby players.

    PubMed

    Kawasaki, Takayuki; Ota, Chihiro; Urayama, Shingo; Maki, Nobukazu; Nagayama, Masataka; Kaketa, Takefumi; Takazawa, Yuji; Kaneko, Kazuo

    2014-11-01

    The incidence of reinjuries due to glenohumeral instability and the major risk factors for primary anterior shoulder dislocation in youth rugby players have been unclear. The purpose of this study was to investigate the incidence, mechanisms, and intrinsic risk factors of shoulder dislocation in elite high-school rugby union teams during the 2012 season. A total of 378 male rugby players from 7 high-school teams were investigated by use of self-administered preseason and postseason questionnaires. The prevalence of a history of shoulder dislocation was 14.8%, and there were 21 events of primary shoulder dislocation of the 74 overall shoulder injuries that were sustained during the season (3.2 events per 1000 player-hours of match exposure). During the season, 54.3% of the shoulders with at least one episode of shoulder dislocation had reinjury. This study also indicated that the persistence of glenohumeral instability might affect the player's self-assessed condition, regardless of the incidence during the current season. By a multivariate logistic regression method, a history of shoulder dislocation on the opposite side before the season was found to be a risk factor for contralateral primary shoulder dislocation (odds ratio, 3.56; 95% confidence interval, 1.27-9.97; P = .02). High-school rugby players with a history of shoulder dislocation are not playing at full capacity and also have a significant rate of reinjury as well as a high risk of dislocating the other shoulder. These findings may be helpful in deciding on the proper treatment of primary anterior shoulder dislocation in young rugby players. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... accompanied by limitation of flexion and extension of the hip. Traumatism is a rare cause of disability in... paralysis attributable to disease affecting the lumbar vertebrae and the intervertebral disc. ...

  5. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... accompanied by limitation of flexion and extension of the hip. Traumatism is a rare cause of disability in... paralysis attributable to disease affecting the lumbar vertebrae and the intervertebral disc. ...

  6. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... accompanied by limitation of flexion and extension of the hip. Traumatism is a rare cause of disability in... paralysis attributable to disease affecting the lumbar vertebrae and the intervertebral disc. ...

  7. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... accompanied by limitation of flexion and extension of the hip. Traumatism is a rare cause of disability in... paralysis attributable to disease affecting the lumbar vertebrae and the intervertebral disc. ...

  8. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... accompanied by limitation of flexion and extension of the hip. Traumatism is a rare cause of disability in... paralysis attributable to disease affecting the lumbar vertebrae and the intervertebral disc. ...

  9. The incidence of avascular necrosis and the radiographic outcome following medial open reduction in children with developmental dysplasia of the hip: a systematic review.

    PubMed

    Gardner, R O E; Bradley, C S; Howard, A; Narayanan, U G; Wedge, J H; Kelley, S P

    2014-02-01

    The incidence of clinically significant avascular necrosis (AVN) following medial open reduction of the dislocated hip in children with developmental dysplasia of the hip (DDH) remains unknown. We performed a systematic review of the literature to identify all clinical studies reporting the results of medial open reduction surgery. A total of 14 papers reporting 734 hips met the inclusion criteria. The mean follow-up was 10.9 years (2 to 28). The rate of clinically significant AVN (types 2 to 4) was 20% (149/734). From these papers 221 hips in 174 children had sufficient information to permit more detailed analysis. The rate of AVN increased with the length of follow-up to 24% at skeletal maturity, with type 2 AVN predominating in hips after five years' follow-up. The presence of AVN resulted in a higher incidence of an unsatisfactory outcome at skeletal maturity (55% vs 20% in hips with no AVN; p < 0.001). A higher rate of AVN was identified when surgery was performed in children aged < 12 months, and when hips were immobilised in ≥ 60° of abduction post-operatively. Multivariate analysis showed that younger age at operation, need for further surgery and post-operative hip abduction of ≥ 60° increased the risk of the development of clinically significant AVN.

  10. Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review.

    PubMed

    Haughom, Bryan D; Erickson, Brandon J; Hellman, Michael D; Jacobs, Joshua J

    2015-08-01

    Although metal-on-metal (MoM) bearing surfaces provide low rates of volumetric wear and increased stability, evidence suggests that certain MoM hip arthroplasties have high rates of complication and failure. Some evidence indicates that women have higher rates of failure compared with men; however, the orthopaedic literature as a whole has poorly reported such complications stratified by gender. This systematic review aimed to: (1) compare the rate of adverse local tissue reaction (ALTR); (2) dislocation; (3) aseptic loosening; and (4) revision between men and women undergoing primary MoM hip resurfacing arthroplasty (HRA). Systematic MEDLINE and EMBASE searches identified all level I to III articles published in peer-reviewed journals, reporting on the outcomes of interest, for MoM HRA. Articles were limited to those with 2-year followup that reported outcomes by gender. Ten articles met inclusion criteria. Study quality was evaluated using the Modified Coleman Methodology Score; the overall quality was poor. Heterogeneity and bias were analyzed using a Mantel-Haenszel statistical method. Women demonstrated an increased odds of developing ALTR (odds ratio [OR], 5.70 [2.71-11.98]; p<0.001), dislocation (OR, 3.04 [1.2-7.5], p=0.02), aseptic loosening (OR, 3.18 [2.21-4.58], p<0.001), and revision (OR, 2.50 [2.25-2.78], p<0.001) after primary MoM HRA. A systematic review of the currently available literature reveals a higher rate of complications (ALTR, dislocation, aseptic loosening, and revision) after MoM HRA in women compared with men. Although femoral head size has been frequently implicated as a prime factor in the higher rate of complication in women, further research is necessary to specifically probe this relationship. Retrospective studies of data available (eg, registry data) should be undertaken, and moving forward studies should report outcomes by gender (particularly complications). Level III, therapeutic study.

  11. A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.

    PubMed

    Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph

    2015-01-01

    Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.

  12. A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions

    PubMed Central

    Herrmann, Sven; Kluess, Daniel; Kaehler, Michael; Grawe, Robert; Rachholz, Roman; Souffrant, Robert; Zierath, János; Bader, Rainer; Woernle, Christoph

    2015-01-01

    Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients. PMID:26717236

  13. Osteochondral Autograft from the Ipsilateral Femoral Head by Surgical Dislocation for Treatment of Femoral Head Fracture Dislocation: A Case Report.

    PubMed

    Won, Yougun; Lee, Gi Soo; Kim, Sang Bum; Kim, Sun Joong; Yang, Kyu Hyun

    2016-11-01

    As anatomical reduction of the articular surface of femoral head fractures and restoration of damaged cartilage are essential for good long-term results, many treatment options have been suggested, including fixation of the fracture using various surgical exposures and implants, as well as arthroscopic irrigation and debridement, bone marrow stimulating techniques, osteochondral allograft, autograft, and autogenous chondrocyte implantation. We report a case of osteochondral autograft harvested from its own femoral articular surface through surgical hip dislocation. The osteochondral graft was harvested from the inferior non-weight-bearing articular surface and grafted to the osteochondral defect. One year later, the clinical and radiological results were good, without the collapse of the femoral head or arthritic change. This procedure introduced in our case is considered convenient and able to lessen surgical time without morbidity of the donor site associated with the harvest.

  14. Is there a relationship between preferred posture and positioning in early life and the direction of subsequent asymmetrical postural deformity in non ambulant people with cerebral palsy?

    PubMed

    Porter, David; Michael, Shona; Kirkwood, Craig

    2008-09-01

    It has been suggested that asymmetrical positioning of an infant with reduced mobility may lead to postural deformity becoming established over time. However, evidence to support or question this line of thinking is lacking. Therefore, the aim of this retrospective cohort study was to test the association between asymmetrical positioning in the first 12 months of life and the subsequent direction of postural deformity in non-ambulant people with cerebral palsy. The direction of scoliosis, pelvic obliquity and windswept hip pattern and also the side of unilateral hip subluxation/dislocation were determined for 246 young people ranging in age from 1 year and 2 months to 19 years (median age 10 years and 3 months). Parents/carers of the participants were interviewed to establish holding and feeding positions and preferred lying posture adopted in early life. Univariate analyses and multivariate logistic regression analyses were carried out. The study provided evidence of an association between asymmetrical lying posture adopted in the first year of life and the direction of the subsequent pattern of postural deformity. If the child's head had been rotated to the right during supine lying, it was more likely that the scoliosis would be convex to the left, pelvic obliquity would be lower on the left, windswept hip pattern would be to the right and hip subluxation/dislocation would occur on the left. The likelihood of the deformities occurring in the same direction was also increased if consistent side lying on the right had been preferred. Clinicians should be aware of positioning for children with severe disabilities particularly those who prefer supine lying with their head rotated to the side and those who prefer consistent side lying.

  15. Complications Are Not Increased With Acetabular Revision of Metal-on-metal Total Hip Arthroplasty.

    PubMed

    Penrose, Colin T; Seyler, Thorsten M; Wellman, Samuel S; Bolognesi, Michael P; Lachiewicz, Paul F

    2016-10-01

    Isolated revision of the acetabular component in the setting of total hip arthroplasty has an increased risk of dislocation. With local soft tissue destruction frequently associated with failed metal-on-metal (MoM) bearings, it is presumed that acetabular revision of these hips will have even greater risk of complications. However, no study directly compares the complications of MoM with metal-on-polyethylene (MoP) acetabular revisions. In the context of a large database analysis, we asked the following questions: (1) Are there differences in early medical or wound complications after isolated acetabular revision of MoM and MoP bearing surfaces? (2) Are there differences in the frequency of dislocation, deep infection, and rerevision based on the bearing surface of the original implant? A review of the 100% Medicare database from 2005 to 2012 was performed using International Classification of Diseases, 9th Revision and Current Procedural Terminology codes. We identified 451 patients with a MoM bearing and 628 patients with a MoP bearing who had an isolated acetabular revision and a minimum followup of 2 years. The incidence, odds ratios, and 95% confidence intervals for early medical or wound complications were calculated using a univariate analysis at 30 days with patient sex and age group-adjusted analysis for blood transfusion. The incidence, odds ratio, and 95% confidence intervals for dislocation, deep infection, and rerevision were calculated using a univariate analysis at 30 day, 90 days, 1 year, and 2 years using a subgroup analysis with the Cochran-Mantel-Haenszel test to adjust for patient gender and age groups. There were no differences between the MoM and MoP isolated acetabular revisions in the incidence of 30-day local complications. There was a greater risk of transfusion in the MoP group than the MoM group (134 of 451 [30%] versus 230 of 628 [37%]; odds ratio [OR], 0.731; 95% confidence interval [CI], 0.565-0.948; p = 0.018). There were no differences at 2 years between the MoM and MoP acetabular revisions in the incidence of dislocation, infection, or rerevision. When analyzed by patient sex and age group, there were more infections in the age 70 to 79 years MoP group compared with MoM (10 of 451 [5%] versus 29 of 628 [10%]; OR, 4.47; CI, 1.699-11.761; p = 0.001). There were high rates of dislocation, infection, and rerevision in both revision cohorts. The rate of dislocation was not greater after acetabular revision of MoM bearings at 2 years. Based on these findings, clinicians should counsel these patients preoperatively about the risks of these complications. Dual-mobility and constrained components have specific advantages and disadvantages in these settings and should be further studied. Level III, therapeutic study.

  16. Prospective monitoring improves outcomes of primary total hip replacement: a cohort study

    PubMed Central

    Streubel, Philipp N; Pachón, Marcela; Kerguelén, Carlos A; Navas, José; Portocarrero, Julio; Pesantez, Rodrigo F; Zayed, Gamal; Carrillo, Germán; Llinás, Adolfo M

    2009-01-01

    Background Over the past decade several studies have questioned current standards of patient safety in health care delivery. In response, our institution started a clinical pathway for total hip replacement in 1996. Prospective monitoring with regular feedback sessions to the individuals involved in patient care did however not start until 2003. The present study evaluates the effect of prospective monitoring on outcomes of total hip replacement. Methods Clinical records of patients undergoing primary elective total hip replacement between 1997 and 2004 were reviewed. Data on adverse events as well as adherence to protocols for venous thromboembolism prophylaxis were extracted retrospectively for the period 1997 to 2001 and prospectively from 2003 to 2004. Results were compared and analyzed in order to establish possible improvement in outcomes. Data was analyzed with Chi-square or Fisher's Exact test for categorical variables and Student's t-test for continuous variables. Alpha was set as less than 5% and analysis was performed with Stata 9.0 for Macintosh. Results Two-hundred and eighty-three patients were included from 1997 to 2001, and 62 from 2003 to 2004. Mean age, male to female ratio and initial diagnosis were similar in both groups. At least one adverse event occurred in 45% of patients in 1997–2001 and in 21% in 2003–2004 (p < 0.001). In-hospital hip dislocations occurred in 6% and 0% (p = 0.05), oliguria in 19% and 5% (p = 0.007), SSI and VTE in 3% and 0% (p = 0.37), adverse drug reactions in 11% and 13% (p = 0.66) and non-adherence to VTE prophylaxis protocols in 15% and 2% of cases respectively (p = 0.002). Conclusion Overall rate of adverse events as well as in-hospital hip dislocations, oliguria and non-adherence to VTE prophylaxis protocols were significantly reduced during the second period. We conclude that clinical pathways alone are insufficient to improve patient safety and require prospective monitoring and continuous feedback to health care providers in order to achieve the desired effect. PMID:19366438

  17. Small bowel entrapment and ureteropelvic junction disruption associated with L3 Chance fracture-dislocation.

    PubMed

    Pesenti, Sebastien; Blondel, Benjamin; Faure, Alice; Peltier, Emilie; Launay, Franck; Jouve, Jean-Luc

    2016-09-16

    Paediatric Chance fracture are rare lesions but often associated with abdominal injuries. We herein present the case of a seven years old patient who sustained an entrapment of small bowel and an ureteropelvic disruption associated with a Chance fracture and spine dislocation following a traffic accident. Initial X-rays and computed tomographic (CT) scan showed a Chance fracture with dislocation of L3 vertebra, with an incarceration of a small bowel loop in the spinal canal and a complete section of the left lumbar ureter. Paraplegia was noticed on the initial neurological examination. A posterior L2-L4 osteosynthesis was performed firstly. In a second time she underwent a sus umbilical laparotomy to release the incarcerated jejunum loop in the spinal canal. An end-to-end anastomosis was performed on a JJ probe to suture the left injured ureter. One month after the traumatism, she started to complain of severe headaches related to a leakage of cerebrospinalis fluid. Three months after the traumatism there was a clear regression of the leakage. One year after the trauma, an anterior intervertebral fusion was done. At final follow-up, no neurologic recovery was noticed. In case of Chance fracture, all physicians should think about abdominal injuries even if the patient is asymptomatic. Initial abdominal CT scan and magnetic resonance imaging provide in such case crucial info for management of the spine and the associated lesions.

  18. Current Concepts in Hip Preservation Surgery

    PubMed Central

    Adler, Kelly L.; Cook, P. Christopher; Geisler, Paul R.; Yen, Yi-Meng; Giordano, Brian D.

    2016-01-01

    Context: Successful treatment of nonarthritic hip pain in young athletic individuals remains a challenge. A growing fund of clinical knowledge has paralleled technical innovations that have enabled hip preservation surgeons to address a multitude of structural variations of the proximal femur and acetabulum and concomitant intra-articular joint pathology. Often, a combination of open and arthroscopic techniques are necessary to treat more complex pathomorphologies. Peri- and postoperative recovery after such procedures can pose a substantial challenge to the patient, and a dedicated, thoughtful approach may reduce setbacks, limit morbidity, and help optimize functional outcomes. Evidence Acquisition: PubMed and CINAHL databases were searched to identify relevant scientific and review articles through December 2014 using the search terms hip preservation, labrum, surgical dislocation, femoroacetabular impingement, postoperative rehabilitation, peri-acetabular osteotomy, and rotational osteotomy. Reference lists of included articles were reviewed to locate additional references of interest. Study Design: Clinical review. Level of Evidence: Level 4. Results: Hip preservation procedures and appropriate rehabilitation have allowed individuals to return to a physically active lifestyle. Conclusion: Effective postoperative rehabilitation must consider modifications and precautions specific to the particular surgical techniques used. Proper postoperative rehabilitation after hip preservation surgery may help optimize functional recovery and maximize clinical success and patient satisfaction. PMID:26733593

  19. Unconstrained tripolar hip implants: effect on hip stability.

    PubMed

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  20. [Injuries to permanent teeth. Part 2: Therapy of avulsion].

    PubMed

    von Arx, Thomas; Chappuis, Vivianne; Hänni, Stefan

    2005-01-01

    The present paper describes the current treatment philosophy of dislocated or avulsed permanent teeth at our school. Splinting and medication (root canal treatment, systemic antibiotics, etc.) are targeted to minimize the initial inflammatory reaction and to reduce post-traumatic complications such as pulp necrosis and/ or external root resorption.

  1. Treatment of Crowe Type-IV Hip Dysplasia Using Cementless Total Hip Arthroplasty and Double Chevron Subtrochanteric Shortening Osteotomy: A 5- to 10-Year Follow-Up Study.

    PubMed

    Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi

    2017-02-01

    The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Congenital joint dislocations caused by carbohydrate sulfotransferase 3 deficiency in recessive Larsen syndrome and humero-spinal dysostosis.

    PubMed

    Hermanns, Pia; Unger, Sheila; Rossi, Antonio; Perez-Aytes, Antonio; Cortina, Hector; Bonafé, Luisa; Boccone, Loredana; Setzu, Valeria; Dutoit, Michel; Sangiorgi, Luca; Pecora, Fabio; Reicherter, Kerstin; Nishimura, Gen; Spranger, Jürgen; Zabel, Bernhard; Superti-Furga, Andrea

    2008-06-01

    Deficiency of carbohydrate sulfotransferase 3 (CHST3; also known as chondroitin-6-sulfotransferase) has been reported in a single kindred so far and in association with a phenotype of severe chondrodysplasia with progressive spinal involvement. We report eight CHST3 mutations in six unrelated individuals who presented at birth with congenital joint dislocations. These patients had been given a diagnosis of either Larsen syndrome (three individuals) or humero-spinal dysostosis (three individuals), and their clinical features included congenital dislocation of the knees, elbow joint dysplasia with subluxation and limited extension, hip dysplasia or dislocation, clubfoot, short stature, and kyphoscoliosis developing in late childhood. Analysis of chondroitin sulfate proteoglycans in dermal fibroblasts showed markedly decreased 6-O-sulfation but enhanced 4-O-sulfation, confirming functional impairment of CHST3 and distinguishing them from diastrophic dysplasia sulphate transporter (DTDST)-deficient cells. These observations provide a molecular basis for recessive Larsen syndrome and indicate that recessive Larsen syndrome, humero-spinal dysostosis, and spondyloepiphyseal dysplasia Omani type form a phenotypic spectrum.

  3. Comparison of the technique of anterior cervical distraction and screw elevating-pulling reduction and conventional anterior cervical reduction technique for traumatic cervical spine fractures and dislocations.

    PubMed

    Li, Haoxi; Huang, Yufeng; Cheng, Changzhi; Lin, Zhoudan; Wu, Desheng

    2017-04-01

    To analyze and confirm the advantages of anterior cervical distraction and screw elevating-pulling reduction which are absent in conventional anterior cervical reduction for traumatic cervical spine fractures and dislocations. A retrospective study was conducted on 86 patients with traumatic cervical spine fractures and dislocations who received one-stage anterior approach treatment for a distraction-flexion injury with bilateral locked facet joints between January 2010 and June 2015. They were 54 males and 32 females with an age ranging from 20 to 73 years (average age, 40.1 ± 5.6 years). These patients were distributed into group A and group B in the sequence of visits, with 44 cases of conventional anterior cervical reduction (group A) and 42 cases of anterior cervical distraction and screw elevating-pulling reduction (group B). Comparison of intraoperative blood loss, operation duration and vertebral reduction rate was made between the two groups. The follow-up time was 12-18 months, and the clinical outcomes of surgery were evaluated according to ASIA score, VAS score and JOA score. Statistically significant difference was revealed between group A and group B in the surgical time and the correction rate of cervical spine dislocation (p < 0.05), with the results of group B better than those of group A. For the two groups, statistically significant difference was shown between the ASIA score, VAS score and JOA score before and after operation (p < 0.05), with the results better after operation, while no statistically significant difference was revealed in such scores between the two groups (p > 0.05), with the therapeutic effect of group A the same with that of group B. Anterior cervical distraction and screw elevating-pulling reduction is simple with low risk, short operation duration, good effect of intraoperative vertebral reduction and well-recovered function after the operation. Meanwhile, as a safe and effective operation method for cervical spine fractures and dislocations, it can reduce postoperative complications and the risk of the iatrogenic cervical spinal cord injury caused by prying or facet joint springing during conventional reduction, having more obvious advantages compared to the conventional surgical reduction adopted by group A, with good cervical spine stability as shown in long-term follow-up. Therefore, it is suitable for clinical promotion and application. Copyright © 2017. Published by Elsevier Ltd.

  4. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  5. Quantification of Femoral Neck Exposure Through a Minimally Invasive Smith-Petersen Approach

    DTIC Science & Technology

    2010-06-01

    Gautier E, et al. Surgical dislocation of the adult hip: A technique with full access to femoral head and acetabulum without the risk of avascular ... necrosis . J Bone Joint Surg (Br). 2001;83:1119 1124. 24. Gautier E, Ganz K, Krugel N, et al. Anatomy of the medial femoral circumflex artery and its

  6. The use of a tripolar articulation in revision total hip arthroplasty: a minimum of 24 months' follow-up.

    PubMed

    Levine, Brett R; Della Valle, Craig J; Deirmengian, Carl A; Breien, Kristoffer M; Weeden, Steven H; Sporer, Scott M; Paprosky, Wayne G

    2008-12-01

    A retrospective cohort study of 31 hips revised with a tripolar articular construct was performed. Patient demographics and preoperative and postoperative information were recorded. Indications for a tripolar construct were recurrent dislocation and the inability to attain intraoperative stability during hip revision. Nine patients (29%) were revised to the tripolar construct after failure of a constrained liner. Twenty patients (65%) had at least one episode of instability before the most recent revision. At a mean follow-up of 38 months, modified Postel scores improved from a mean of 5.28 to 9.64 (P < .01). Radiographic follow-up revealed no evidence of component loosening/migration, osteolysis, or polyethylene wear. Two patients (7%) required further revision surgery for recurrent instability. A tripolar construct was effective in eliminating or preventing instability in 93% of the complex cases treated. These early results support the use of a tripolar construct in treating recurrent instability or instability encountered at the time of revision hip arthroplasty.

  7. Long-term clinical and radiographic outcome of the PPF system in ceramic-on-polyethylene hip bearings.

    PubMed

    Legenstein, R; Huber, W; Ungersboeck, A; Boesch, P

    2006-01-01

    From 1990 to 1991 we implanted 176 non-cemented proximal press-fit (PPF) total hip arthroplasties (THA) with ceramic-on-polyethylene articulation in 170 patients. Of these, 119 patients (122 THA) were followed from 104 to 129 months. Four cups have been revised for aseptic loosening, but revealed no radiolucencies of the stem. Two infections and two dislocations occurred. The median postoperative Harris hip score was 91. Ninety-eight per cent of the patients were satisfied with the outcome, 83% were free of pain and 67% walked without a limp. Serial radiographs showed stable fixation with bone ongrowth in nearly all arthroplasties except for four cups. Stem radiolucencies were first seen within 12 months, but were of no clinical relevance. Proximal periprosthetic bone resorption of the stem was seen in 18%. Radiolucencies occurred because of polyethylene debris-induced granulomas. The PPF system yields satisfactory long-term results in patients with primary and secondary hip osteoarthritis and dysplasia.

  8. Magnetic resonance imaging with gadolinium arthrography to assess acetabular cartilage delamination.

    PubMed

    Zaragoza, Edward; Lattanzio, Pierre-Jean; Beaule, Paul E

    2009-01-01

    Recent reports have demonstrated magnetic resonance imaging (MRI) as a promising technique in detecting articular cartilage lesions of the hip joint. The purpose of our study was to evaluate the diagnostic performance of MRI with gadolinium arthrography in detecting acetabular cartilage delamination in patients with pre-arthritic hip pain. 46 patients (48 hips) underwent surgical dislocation of the hip. Mean age was 38.8 (range 17-56). There were 26 males and 20 females. All patients had Magnetic Resonance Imaging with gadolinium arthrography (MRA) before undergoing open hip surgery where the acetabular cartilage was inspected. Acetabular cartilage delamination on MRA was seen on sagittal images as a linear intra-articular filling defect of low signal intensity >1mm in thickness on T1 weighted images and surrounded by contrast. On MRA all hips had a labral tear confirmed at surgery. At surgery 30 hips had evidence of acetabular cartilage delamination, 4 hips had ulceration and 14 had no articular cartilage damage. The majority of labral tears and cartilage damage were located in the antero-superior quadrant. The sensitivity and specificity of MRA detection of cartilage delamination confirmed at surgery were 97% and 84%, respectively. The positive and negative predictive values of the MRA finding were 90% and 94%, respectively. The presence of the acetabular cartilage delamination represents an early stage of articular cartilage degeneration. When evaluating a young adult with hip pain, labral tears in association with cartilage delamination should be considered. MRA represents an effective diagnostic tool.

  9. Surgical management of post-traumatic atlantoaxial rotatory fixation due to C2 facet fracture: 5 clinical cases.

    PubMed

    Peyriere, H; Graillon, T; Pesenti, S; Tropiano, P; Blondel, B; Fuentes, S

    2017-02-01

    Report the results of surgical treatment of post-traumatic atlantoaxial rotatory fixation (AARF) due to C2 articular facet fracture in adults. The records of five patients treated since 2009 for AARF due to a C2 articular facet fracture were analyzed retrospectively. Three women and two men with an average age of 60 years (27-82) were included, one of whom initially had neurological deficits. In all cases, the surgical strategy consisted of posterior fixation: Harms-type in four cases and trans-articular with hooks in one case. Dislocations due to fracture of the C2 articular facet are rare in adults; various treatment strategies have been described. In our experience, posterior screw fixation leads to satisfactory clinical and radiological outcomes. Fusion is not necessary in these cases because the dislocation is related to an asymmetric fracture without ligament damage. Posterior fixation provides satisfactory reduction of these injuries and leads to satisfactory bone union. This surgical treatment can be performed early on after the trauma and is an interesting alternative to conservative treatment. Copyright © 2016. Published by Elsevier Masson SAS.

  10. TEM study on relationship between stacking faults and non-basal dislocations in Mg

    NASA Astrophysics Data System (ADS)

    Zhang, Dalong; Jiang, Lin; Schoenung, Julie M.; Mahajan, Subhash; Lavernia, Enrique J.

    2015-12-01

    Recent interest in the study of stacking faults and non-basal slip in Mg alloys is partly based on the argument that these phenomena positively influence mechanical behaviour. Inspection of the published literature, however, reveals that there is a lack of fundamental information on the mechanisms that govern the formation of stacking faults, especially I1-type stacking faults (I1 faults). Moreover, controversial and sometimes contradictory mechanisms have been proposed concerning the interactions between stacking faults and dislocations. Therefore, we describe a fundamental transmission electron microscope investigation on Mg 2.5 at. % Y (Mg-2.5Y) processed via hot isostatic pressing (HIP) and extrusion at 623 K. In the as-HIPed Mg-2.5Y, many and dislocations, together with some dislocations were documented, but no stacking faults were observed. In contrast, in the as-extruded Mg-2.5Y, a relatively high density of stacking faults and some non-basal dislocations were documented. Specifically, there were three different cases for the configurations of observed stacking faults. Case (I): pure I2 faults; Case (II): mixture of I1 faults and non-basal dislocations having component, together with basal dislocations; Case (III): mixture of predominant I2 faults and rare I1 faults, together with jog-like dislocation configuration. By comparing the differences in extended defect configurations, we propose three distinct stacking fault formation mechanisms for each case in the context of slip activity and point defect generation during extrusion. Furthermore, we discuss the role of stacking faults on deformation mechanisms in the context of dynamic interactions between stacking faults and non-basal slip.

  11. A preliminary investigation on the effect of extracorporeal shock wave therapy as a treatment for neurogenic heterotopic ossification following traumatic brain injury. Part II: Effects on function.

    PubMed

    Reznik, J E; Biros, E; Sacher, Y; Kibrik, O; Milanese, S; Gordon, S; Galea, M P

    2017-01-01

    Neurogenic heterotopic ossification (NHO) occurs as a complication of traumatic brain injury (TBI). Management of clinically significant NHO remains variable. Complications of mature NHO include limitation of mobility. The effect of the extracorporeal shock wave therapy (ESWT) on range of motion at hip and knee, and function in patients with TBI with chronic NHO was investigated. A series of single-case studies applying ESWT to chronic NHO at the hip or knee of 11 patients with TBI were undertaken at a rehabilitation hospital. Participants received four applications of high-energy EWST delivered to the affected hip or knee over a period of 8 weeks. Two-weekly follow- up assessments were carried out; final assessments were made 3 and 6 months post-intervention. Range of motion (ROM) and Functional Reach (FR) or Modified Functional Reach (MFR) were measured. Application of high-energy ESWT was associated with significant improvement in ROM (flexion) of the NHO-affected knee (Tau = 0.833, 95% CI 0.391-1.276, p = 0.002) and significant improvement of FR (Overall Tau 0.486, 95% CI 0.141-0.832, p = 0.006); no significant improvement in hip ROM or MFR. ESWT may improve mobility and balance of patients with TBI who have chronic NHO.

  12. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Healy, W.L.; Lo, T.C.; Covall, D.J.

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less

  13. [Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].

    PubMed

    Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua

    2017-12-25

    To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.

  14. Management of irreducible unilateral facet joint dislocations in subaxial cervical spine: two case reports and a review of the literature.

    PubMed

    Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng

    2018-03-21

    Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.

  15. [Which hip articulation bearing for which patient? : Tribology of the future].

    PubMed

    Morlock, M M; Bishop, N; Kaddick, C

    2011-12-01

    Replacement of the hip joint has become an exceptionally successful procedure since the inauguration of the low friction principle by Charnley. Aseptic osteolysis and joint dislocation have been addressed by the development of wear-optimized materials and the introduction of larger heads. As an increase in head diameter against polyethylene causes wear increase, larger hard-on-hard bearings were introduced, which exhibit reduced wear and reduced dislocation risk with increasing head diameter. These findings were derived from standard simulator testing, not sufficiently considering the risk of fluid film breakdown under adverse conditions, which can cause a dramatic increase in wear and friction proportional to the head diameter. Such adverse conditions can occur clinically in patients due to several factors and have caused the presently observed unexpected problems with these new designs. Standardized preclinical testing has to be viewed as a minimum requirement but certainly not as a guarantee for the clinical success of new materials and designs even if the testing is adapted to the current patient requirements, which is presently not the case. The future of tribology lies in the prevention of adverse conditions in patients, the improvement and optimized use of proven existing materials and not in the use of new materials.

  16. Microstructure and Charpy impact properties of 12 14Cr oxide dispersion-strengthened ferritic steels

    NASA Astrophysics Data System (ADS)

    Oksiuta, Z.; Baluc, N.

    2008-02-01

    This paper describes the microstructure and Charpy impact properties of 12-14 Cr ODS ferritic steels fabricated by mechanical alloying of pure Fe, Cr, W, Ti and Y 2O 3 powders in a Retsch ball mill in argon atmosphere, followed by hot isostatic pressing at 1100 °C under 200 MPa for 4 h and heat treatment at 850 °C for 1 h. Weak Charpy impact properties were obtained in the case of both types of as-hipped materials. In the case of 14Cr materials, the weak Charpy properties appeared related to a bimodal grain size distribution and a heterogeneous dislocation density between the coarse and fine grains. No changes in microstructure were evidenced after heat treatment at 850 °C. Significant improvement in the transition temperature and upper shelf energy of 12Cr materials was obtained by heat treatment at 850 °C for 1 h, which was attributed to the formation of smaller grains, homogenous in size and containing fewer dislocations, with respect to the as-hipped microstructure. This modified microstructure results in a good compromise between strength and Charpy impact properties.

  17. Efficacy of Kirschner-wires and tension band in hip arthroplasty for aged patients with unstable intertrochanteric osteoporotic fracture

    PubMed Central

    Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian

    2017-01-01

    Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698

  18. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    PubMed

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  19. Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.

    PubMed

    Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.

  20. Bipolar Hemarthroplasty Using Cementless Conical Stem for Treatment of Dorr Type B and C Femoral Neck Fracture.

    PubMed

    Kang, Jeong Hoon; Lee, Sang Hong; Jung, Sung

    2015-12-01

    The current study aims to evaluate the clinical and the radiological outcome of bipolar hemiarthroplasty using cementless cone stem to treat osteoporotic femoral neck fracture and compare the results according to the proximal femur geometry. Seventy-five hips (75 patients) that underwent bipolar hemiarthroplasty with cementless cone stem between September 2006 and December 2011 were analyzed. The minimum follow-up period was 3 years. Thirty-three hips were classified as type B and 41 as type C. The clinical outcome was assessed using Harris hip score and the walking ability score. Radiographic evaluation was performed to evaluate the stability of the prosthesis. At the most recent follow up, the mean Harris hip score was 86 (range, 70-92) and 65% recovered to preoperative ambulatory status. In the radiographic exam, stable stem fixation was achieved in all cases. For the complications, eight hips developed deep vein thrombosis while three hips showed heterotopic ossification. Dislocation and delayed deep infection occurred in one hip resepectively. There were no significance differences in Harris hip score and walking ability score when the type B group was compare with the type C. Bipolar hemiarthroplasty with cementless cone stem showed an excellent early outcome both clinically and radiographically regardless of the shape of the proximal femur. We believe this prosthesis can provide early stability to the Dorr type B and C femur and is an effective treatment for treating osteoporotic femoral neck fracture.

  1. [Short-term curative effects of Tantalum rod treatment in early avascular necrosis].

    PubMed

    Ye, Fu-Sheng; Ni, Zhe-Ji; Chu, Xiao-Bing; He, Bang-Jian; Li, Ju; Tong, Pei-Jian

    2013-08-01

    To explore the recent clinical curative effect of Tantalum rod in treating the early avascular necrosis. From January 2008 to November 2008, the 25 patients (39 hips) with early avascular necrosis accepted tantalum rod placement and included 9 males (11 hips) and 16 females (28 hips) with an average age of 37 years old ranging from 18 to 74 years old. Four patients (6 hips) caused by Alcoholic, 6 patients (8 hips) by hormone, 2 cases (2 hips) by traumatic, 13 cases (23 hips) by idiopathic. Steinberg preoperative stage involved 7 hips in period I, 24 hips in period II, 8 hips in period III. Curative effect analysis included preoperative and postoperative Harris score, radiographic changes and hip replacement for follow-up to accept the end of the femoral head survival rate. All patients were followed up for 6 to 47 months (averaged 37.4 months). All 12 hips imaging appeard progress,including tantalum rod exit in 1 hip, hip hemiarthroplasty collapse in 3 hips, the area increased to avascular necrosis in 8 hips. Six hips accepted total hip replacement, including imaging progress in 5 hips (41.7%, 5/12), no imaging progress in 1 hip (3.7%,1/27). All hips' Kaplan-Meier survival curves showed 6-month survival rate was (97.4 +/- 2.5)% after tantalum stick insertion, 1-year survival rate was (94.7 +/- 3.6), and 2-year survival rate was (88.6 +/- 5.4)%, 3-year survival rate was (72.5 +/- 11.2). It is effective for treatment of avascular necrosis of femoral head in Steinberg I and II by Tantalum rod, and it can effectively relieve femoral head replacement time.

  2. Arthroscopic treatment of acute acromioclavicular joint dislocation by coracoclavicular ligament augmentation.

    PubMed

    Liu, Xudong; Huangfu, Xiaoqiao; Zhao, Jinzhong

    2015-05-01

    Coracoclavicular (CC) ligament augmentation has been a method to treat acromioclavicular (AC) joint dislocation in recent years. The purpose of this paper is to describe our arthroscopic CC ligament augmentation technique in treating type III and V acute AC joint dislocations and to report the early clinical and radiological results. From 2010 to 2011, twelve patients suffering from acute type III or V AC joint dislocations were arthroscopically treated in our department, by CC ligament augmentation after AC joint reduction. The post-operative outcomes were assessed through physical examination, radiographic examination and the Constant-Murley Shoulder Score. All patients post-operatively experienced anatomical reduction in their AC joint dislocation. No intraoperative complications occurred. At a mean follow-up at 24 months (ranging from 18 to 32 months), the mean Constant-Murley Shoulder Score significantly improved from 24.3 pre-operatively to 91.1 post-operatively. No neurovascular complications or secondary degenerative changes of the AC joint were detected in any of the patients. In one case, a second dislocation occurred 1 month post-operation because the patient had had another traumatic injury. This patient accepted a revision operation, but his AC joint eventually fixated into a subluxated position after his second injury. Based on the resultant successful repair in all cases, the arthroscopic CC ligament augmentation method has thus far proven to be a safe and reliable technique for treatment of acute type III or V AC joint dislocation. The arthroscopic CC ligament augmentation with a flip button/polyethylene belt repair is an efficient method to treat acute type III and V AC joint dislocations which should be popularized. IV.

  3. 3D surgical printing and pre contoured plates for acetabular fractures.

    PubMed

    Chana-Rodríguez, Francisco; Mañanes, Rubén Pérez; Rojo-Manaute, José; Gil, Pablo; Martínez-Gómiz, José María; Vaquero-Martín, Javier

    2016-11-01

    We describe the methodical and possibilities of 3D surgical printing in preoperative planning of acetabular fractures showing a case of a 45-year-old with an associated transverse fracture of the left acetabulum with posterior wall fracture, with multiple fragments, and posterior ipsilateral hip dislocation, defending the do it your-self mode. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Can cemented dual-mobility cups be used without a reinforcement device in cases of mild acetabular bone stock alteration in total hip arthroplasty?

    PubMed

    Haen, T X; Lonjon, G; Vandenbussche, E

    2015-12-01

    Cemented versions of dual-mobility cups (DMCs), helpful in cases of bone stock alteration, are usually used in association with a reinforcement device. To simplify the intervention in elderly subjects or those with a poor bone stock, the cups can be cemented directly into the bone, but the long-term result remains uncertain. We conducted a retrospective study in this population so as to: (1) assess whether cemented fixation of a DMC without a reinforcement device leads to a higher loosening rate, (2) confirm its efficacy in preventing dislocations in subjects at high risk of instability, and (3) measure the functional results. Cemented fixation of a DMC is reliable in cases of moderate alteration of bone stock. Sixty-four patients (66 hips) undergoing implantation of a cemented DMC (Saturne™) without a reinforcement device were included in this single-center retrospective study. Their mean age was 79.8 years (range, 40-95 years). The indications varied: hip osteoarthritis (30.3%), prosthesis revision (44.0%), and trauma (25.8%). The patients were evaluated radiologically and clinically at follow-up. The main evaluation criterion was the revision rate for aseptic loosening. Dislocations, the infection rate, and the Postel Merle d'Aubigné (PMA) score were noted. At the mean follow-up of 4.2 years, three (4.6%) patients had been lost to follow-up and 22 (33.3%) had died. There was one case of aseptic loosening (1.5%). Cup survival was 98% at 5 years (95%CI [94-100]). There were no dislocations. There was one revision for infection. The mean PMA score was 15.5 (range, 9-18). The frequency of acetabular loosening was comparable to the frequency in cemented DMCs with a reinforcement device. A cemented DMC without a reinforcement device is possible and is a simple and viable option when there is moderate bone stock alteration. IV, retrospective cohort study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. The Transverse Acetabular Ligament as an Intraoperative Guide to Cup Abduction.

    PubMed

    Hiddema, Willem B; van der Merwe, Johan F; van der Merwe, Werner

    2016-07-01

    The success of a total hip arthroplasty relies on optimal acetabular cup placement to ensure mating of the femoral head and acetabular cup throughout all positions of the hip joint. Poor cup placement is associated with dislocation, impingement, microseparation, component loosening, and accelerated wear due to rim loading. This study examined a novel method of using the transverse acetabular ligament (TAL) to guide cup inclination during primary total hip arthroplasty. A descriptive study using 16 hips from 9 cadavers. A computer navigation system measured inclination and version of the acetabular component in 3 positions with the lower edge of cup: (1) flush with, (2) 5 mm proximal to, and (3) 5 mm distal to free border of the TAL. The median inclination angles were 44° in position (1), 30° in position (2), and 64° in position (3). The median anteversion angle for all positions was 19°. Cup inclination was acceptable when the lower edge of the cup was flush or within 5 mm proximal to the TAL. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Trauma of the upper cervical spine: focus on vertical atlantoaxial dislocation.

    PubMed

    Pissonnier, M L; Lazennec, J Y; Renoux, J; Rousseau, M A

    2013-10-01

    Traumatic ligament injuries of the craniovertebral junction, either isolated or associated with bone avulsion or fracture, often lead to death. These injuries are rare and underrated but are increasingly seen in emergency departments due to the improvement in initial on-scene management of accidents. Vertical atlantoaxial dislocation (AAD) is a specific lesion that was barely reported. Based on our experience, our goal was to systematically investigate the prevalence and prognosis of traumatic vertical AAD and discuss its management. All cervical CT scans performed at our institution between 2006 and 2010 for cervical trauma in adults were retrospectively reviewed. Based on the measurement of lateral mass index (LMI), defined as the gap between C1 and C2 articular facets, we identified three cases of traumatic vertical AAD in 300 CT scans. Their medical records were investigated. The incidence of vertical AAD was 1% in the exposed population. One case was an isolated vertical AAD and two were associated with a type II odontoid fracture. We report the first case in the literature of unilateral vertical AAD. Two patients died rapidly; the survivor was treated with occipitocervical fixation. Specific maneuvers were used for immobilization and reduction. This study found a not insignificant incidence of vertical AAD and a high lethality rate. LMI appears to be a relevant radiological criterion for this diagnosis, for which traction is contraindicated. Associated neurological or vascular damage should be suspected and investigated. In our experience, spinal surgical fixation is required because of major instability.

  7. Risk of contralateral avascular necrosis (AVN) after total hip arthroplasty (THA) for non-traumatic AVN.

    PubMed

    Goker, Berna; Block, Joel A

    2006-01-01

    The risk of developing bilateral disease progressing to total hip arthroplasty (THA) among patients who undergo unilateral THA for non-traumatic avascular necrosis (AVN) remains poorly understood. An analysis of the time-course to contralateral THA, as well as the effects of underlying AVN risk factors, is presented. Forty-seven consecutive patients who underwent THA for AVN were evaluated. Peri-operative and annual post-operative antero-posterior pelvis radiographs were examined for evidence of contralateral involvement. Patient age, weight, height, underlying AVN risk factor(s), date of onset of contralateral hip pain if occurred, and date of contralateral THA if performed, were recorded. Bone scan, computerized tomography and magnetic resonance imaging data were utilized when available. Twenty-one patients (46.6%) underwent contralateral THA for AVN within a median of 9 months after the initial THA (range 0-93, interquartile range 28.5 months). The median follow-up for patients without contralateral THA was 75 months (range 3-109, interquartile range 69 months). Thirty-four patients had radiographic findings of contralateral AVN at study entry; 25 were symptomatic bilaterally at entry and 7 developed contralateral symptoms within a mean time of 12 months (median 10 months, interquartile range 12 months). None of the 13 patients who were free of radiographic evidence of contralateral AVN at study entry developed evidence of AVN during the follow-up. AVN associated with glucocorticoid use was more likely to manifest as bilateral disease than either idiopathic AVN or ethanol-associated AVN (P=0.02 and P=0.03 respectively). Radiographically-evident AVN in the contralateral hip at THA is unlikely to remain asymptomatic for a prolonged period of time. Conversely, asymptomatic contralateral hips without radiographic evidence of AVN are unlikely to develop clinically significant AVN.

  8. Enhanced arm swing alters interlimb coordination during overground walking in individuals with traumatic brain injury.

    PubMed

    Ustinova, Ksenia I; Langenderfer, Joseph E; Balendra, Nilanthy

    2017-04-01

    The current study investigated interlimb coordination in individuals with traumatic brain injury (TBI) during overground walking. The study involved 10 participants with coordination, balance, and gait abnormalities post-TBI, as well as 10 sex- and age-matched healthy control individuals. Participants walked 12m under two experimental conditions: 1) at self-selected comfortable walking speeds; and 2) with instructions to increase the amplitude and out-of-phase coordination of arm swinging. The gait was assessed with a set of spatiotemporal and kinematic parameters including the gait velocity, step length and width, double support time, lateral displacement of the center of mass, the amplitude of horizontal trunk rotation, and angular motions at shoulder and hip joints in sagittal plane. Interlimb coordination (coupling) was analyzed as the relative phase angles between the left and right shoulders, hips, and contralateral shoulders and hips, with an ideal out-of-phase coupling of 180° and ideal in-phase coupling of 0°. The TBI group showed much less interlimb coupling of the above pairs of joint motions than the control group. When participants were required to increase and synchronize arm swinging, coupling between shoulder and hip motions was significantly improved in both groups. Enhanced arm swinging was associated with greater hip and shoulder motion amplitudes, and greater step length. No other significant changes in spatiotemporal or kinematic gait characteristics were found in either group. The results suggest that arm swinging may be a gait parameter that, if controlled properly, can improve interlimb coordination during overground walking in patients with TBI. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Interventions for Hip Pain in the Maturing Athlete

    PubMed Central

    Gomberawalla, M. Mustafa; Kelly, Bryan T.; Bedi, Asheesh

    2014-01-01

    Context: Femoroacetabular impingement (FAI) alters hip mechanics, results in hip pain, and may lead to secondary osteoarthritis (OA) in the maturing athlete. Hip impingement can be caused by osseous abnormalities in the proximal femur or acetabulum. These impingement lesions may cause altered loads within the hip joint, which result in repetitive collision damage or sheer forces to the chondral surfaces and acetabular labrum. These anatomic lesions and resultant abnormal mechanics may lead to early osteoarthritic changes. Evidence Acquisition: Relevant articles from the years 1995 to 2013 were identified using MEDLINE, EMBASE, and the bibliographies of reviewed publications. Level of Evidence: Level 4. Results: Improvements in hip arthroscopy have allowed FAI to be addressed utilizing the arthroscope. Adequately resecting the underlying osseous abnormalities is essential to improving hip symptomatology and preventing further chondral damage. Additionally, preserving the labrum by repairing the damaged tissue and restoring the suction seal may theoretically help normalize hip mechanics and prevent further arthritic changes. The outcomes of joint-preserving treatment options may be varied in the maturing athlete due to the degree of underlying OA. Irreversible damage to the hip joint may have already occurred in patients with moderate to advanced OA. In the presence of preexisting arthritis, these patients may only experience fair or even poor results after hip arthroscopy, with early conversion to hip replacement. For patients with advanced hip arthritis, total hip arthroplasty remains a treatment option to reliably improve symptoms with good to excellent outcomes and return to low-impact activities. Conclusion: Advances in the knowledge base and treatment techniques of intra-articular hip pain have allowed surgeons to address this complex clinical problem with promising outcomes. Traditionally, open surgical dislocations for hip preservation surgery have shown good long-term results. Improvements in hip arthroscopy have led to outcomes equivalent to open surgery while utilizing significantly less invasive techniques. However, outcomes may ultimately depend on the degree of underlying OA. When counseling the mature athlete with hip pain, an understanding of the underlying anatomy, degree of arthritis, and expectations will help guide the treating surgeon in offering appropriate treatment options. PMID:24427445

  10. "Grief that Has No Vent in Tears, Makes Other Organs Weep." Seeking Refuge from Trauma in the Medical Setting

    ERIC Educational Resources Information Center

    Martin, Paddy

    2012-01-01

    This paper will look at work carried out with asylum-seeking families and children within a hospital paediatric setting, exploring theories that can help us to understand how highly traumatic experiences, emotionally and cognitively unprocessed, may become expressed bodily. The case examples will show how these shattered and dislocated patients…

  11. The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up.

    PubMed

    Kim, Y-H

    2008-03-01

    This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.

  12. Non-traumatic limping in Paediatric Emergencies: Epidemiology, evaluation and results.

    PubMed

    Lázaro Carreño, M I; Fraile Currius, R; García Clemente, A

    Non-traumatic limping is a common reason for consultation in paediatric emergencies. Although transient synovitis of the hip (TS) is the most frequent diagnosis, there are cases of limping secondary to serious pathologies. The aim of this review is to describe the variables related to non-traumatic limp that come to the paediatric emergency department to establish the best management protocol, making the most of resources and speeding up emergency care. A prospective study was conducted, selecting all children less than 15 years old who consulted aspaediatric emergencies for non-traumatic limping during the 2014. Clinical variables, complementary examinations and diagnoses were collected in the emergency room consultation and 6 months after the consultation RESULTS: During 2014, 146 patients (0.69% of the emergencies) were included in the non-traumatic limping study. Four cases of severe limping were diagnosed: 2 leukaemias, 1 septic arthritis and 1 acetabular bone tumour. The most frequent diagnosis was TS (53.16%). At 6 months, 135 children (92.4%) had resolved lameness. The diagnosis was changed in 9 children (6.1%). Children with TS had fewer days of evolution, and 77% were between 3 and 10 years old. Children with a final diagnosis of severe pathology had a limp for longer, fever and did not weight bear on ambulation. In limping of probable hip origin, at the ages of between 3 and 10, without fever or systemic symptoms and of less than one week's onset, it is possible to make a clinical diagnosis of TS limiting the use of complementary examinations. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Total vertebrectomy and spine shortening for the treatment of T12-L1 spine dislocation: Management with suboptimal resources.

    PubMed

    Lorente, Alejandro; Palacios, Pablo; Burgos, Jesús; Barrios, Carlos; Lorente, Rafael

    2018-04-21

    Total vertebrectomy with spine shortening has been reported for the treatment of difficult cases of traumatic spine dislocation, both in acute and chronic phase. We report an exceptional case of a five-week-old T12-L1 spine dislocation in a 25-year-old female with complete paraplegia as a result of trauma in Ciudad de León (Nicaragua). In view of the time since the dislocation, we performed a complete L1 vertebrectomy in order to reduce the dorsolumbar hinge. For osteosynthesis material we had only eight screws and two Steffee plates. We therefore introduced pedicle screws at levels T11, T12, L2 and L3 on the right side and T11, T12, L3 and L4 on the left, and performed manual reduction of the spine. Steffee plates were placed and we added sublaminar wires to reinforce the osteosynthesis. Fifteen months after surgery, there has been no neurological improvement. Copyright © 2018 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Traumatic dislocation of the incudostapedial joint repaired with fibrin tissue adhesive.

    PubMed

    Nikolaidis, Vasilios

    2011-03-01

    We present a case of traumatic dislocation of the incudostapedial joint (ISJ) and a simple method for controlled application of the glue using commercial fibrin tissue adhesive. A 26-year-old female presented to our ENT clinic for hearing impairment to her left ear 2 months after a head trauma due to a motorcycle accident. The audiogram revealed a 40- to 50-dB HL conductive hearing loss with a notch configuration in bone conduction curve on the left ear. Computed tomography of the left temporal bone revealed a longitudinal fracture line. An exploratory tympanotomy was performed under general anesthesia. The ISJ was found dislocated while the incus was trapped by the edges of the bony lateral attic wall fracture. A small bony edge that impeded incus movement was removed and a small amount of the glue was precisely applied to the lenticular process of the incus with an angled incision knife. The long process of the incus was firmly pressed over the stapes for 30 seconds with a 90° hook and 60 seconds after the application of the glue the ISJ was repaired. One year after our patient achieved full airbone gap (ABG) closure (ABG, ≤10 dB HL), while she demonstrated overclosure in frequencies 2 and 4 kHz. Fibrin tissue glue allowed safe, rapid, and accurate repair of the ISJ and resulted in an anatomically normal articulation as the mass and shape of the ossicles was preserved. Moreover, our patient achieved full ABG closure. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  15. [Recommendations for Diagnosis and Treatment of Fractures of the Ring of Axis].

    PubMed

    Scholz, Matti; Schleicher, Philipp; Kandziora, Frank; Badke, Andreas; Dreimann, Marc; Gebhard, Harry; Gercek, Erol; Gonschorek, Oliver; Hartensuer, René; Jarvers, Jan-Sven Gilbert; Katscher, Sebastian; Kobbe, Philipp; Koepp, Holger; Korge, Andreas; Matschke, Stefan; Mörk, Sven; Müller, Christian W; Osterhoff, Georg; Pécsi, Ferenc; Pishnamaz, Miguel; Reinhold, Maximilian; Schmeiser, Gregor; Schnake, Klaus John; Schneider, Kristian; Spiegl, Ulrich Josef Albert; Ullrich, Bernhard

    2018-06-22

    In a consensus process with four sessions in 2017, the working group "upper cervical spine" of the German Society for Orthopaedics and Trauma Surgery (DGOU) formulated "Therapeutic Recommendations for the Diagnosis and Treatment of Upper Cervical Fractures", taking their own experience and the current literature into consideration. The following article describes the recommendations for axis ring fractures (traumatic spondylolysis C2). About 19 to 49% of all cervical spine injuries include the axis vertebra. Traumatic spondylolysis of C2 may include potential discoligamentous instability C2/3. The primary aim of the diagnostic process is to detect the injury and to determine potential disco-ligamentous instability C2/3. For classification purposes, the Josten classification or the modified Effendi classification may be used. The Canadian C-spine rule is recommended for clinical screening for C-spine injuries. CT is the preferred imaging modality and an MRI is needed to determine the integrity of the discoligamentous complex C2/3. Conservative treatment is appropriate in case of stable fractures with intact C2/3 motion segment (Josten type 2 and 2). Patients should be closely monitored, in order to detect secondary dislocation as early as possible. Surgical treatment is recommended in cases of primary severe fracture dislocation or discoligamentous instability C2/3 (Josten 3 and 4) and/or secondary fracture dislocation. Anterior cervical decompression and fusion (ACDF) C2/3 is the treatment of choice. However, in case of facet joint luxation C2/3 with looked facet (Josten 4), a primary posterior approach may be necessary. Georg Thieme Verlag KG Stuttgart · New York.

  16. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    PubMed

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  17. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    PubMed

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Labral Reattachment in Femoroacetabular Impingement Surgery Results in Increased 10-year Survivorship Compared With Resection.

    PubMed

    Anwander, Helen; Siebenrock, Klaus A; Tannast, Moritz; Steppacher, Simon D

    2017-04-01

    Since the importance of an intact labrum for normal hip function has been shown, labral reattachment has become the standard method for open or arthroscopic treatment of hips with femoroacetabular impingement (FAI). However, no long-term clinical results exist evaluating the effect of labral reattachment. A 2-year followup comparing open surgical treatment of FAI with labral resection versus reattachment was previously performed at our clinic. The goal of this study was to report a concise followup of these patients at a minimum of 10 years. We asked if patients undergoing surgical hip dislocation for the treatment of mixed-type FAI with labral reattachment compared with labral resection had (1) improved hip pain and function based on the Merle d'Aubigné-Postel score; and (2) improved survival at 10-year followup. Between June 1999 and July 2002, we performed surgical hip dislocation with femoral neck osteoplasty and acetabular rim trimming in 52 patients (60 hips) with mixed-type FAI. In the first 20 patients (25 hips) until June 2001, a torn labrum or a detached labrum in the area of acetabular rim resection was resected. In the next 32 patients (35 hips), reattachment of the labrum was performed. The same indications were used to perform both procedures during the periods in question. Of the 20 patients (25 hips) in the first group, 19 patients (95%) (24 hips [96%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 13 years; range, 12-14 years). Of the 32 patients (35 hips) in the second group, 29 patients (91%) (32 hips [91%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 12 years; range, 10-13 years). We used the anterior impingement test to assess pain. Function was assessed using the Merle d'Aubigné- Postel score and ROM. Survivorship calculation was performed using the method of Kaplan-Meier with failure defined as conversion to THA, progression of osteoarthritis (of one grade or more on the Tönnis score), and a Merle d'Aubigné-Postel score < 15. At the 10-year followup, hip pain in hips with labral reattachment was slightly improved for the postoperative Merle d'Aubigné-Postel pain subscore (5.0 ± 1.0 [3-6] versus 3.9 ± 1.7 [0-6]; p = 0.017). No difference existed for the prevalence of hip pain assessed using the anterior impingement test with the numbers available (resection group 52% [11 of 21 hips] versus reattachment group 27% [eight of 30 hips]; odds ratio, 3.03; 95% confidence interval [CI], 0.93-9.83; p = 0.062). Function was slightly better in the reattachment group for the overall Merle d'Aubigné-Postel score (16.7 ± 1.5 [13-18] versus 15.3 ± 2.4 [9-18]; p = 0.028) and hip abduction (45° ± 13° [range, 30°-70°] versus 38° ± 8° [range, 25°-45°]; p = 0.001). Hips with labral reattachment showed a better survival rate at 10 years than did hips that underwent labral resection (78%; 95% CI, 64%-92% versus 46%, 95% CI, 26%-66%; p = 0.009) with the endpoints defined as conversion to THA, progression of osteoarthritis, and a Merle d'Aubigné-Postel score < 15. With isolated endpoints, survival at 10 years was increased for labral reattachment and the endpoint Merle d'Aubigné score < 15 (83%, 95% CI, 70%-97% versus 48%, 95% CI, 28%-69%; p = 0.009) but did not differ for progression of osteoarthritis (83%, 95% CI, 68%-97% versus 81%, 95% CI, 63%-98%; p = 0.957) or conversion to THA (94%, 95% CI, 86%-100% versus 87%, 95% CI, 74%-100%; p = 0.366). The current results suggest the importance of preserving the labrum and show that resection may put the hip at risk for early deterioration. At 10-year followup, hips with labral reattachment less frequently had a decreased Merle d'Aubigné score but no effect on progression of osteoarthritis or conversion to THA could be shown. Level III, therapeutic study.

  19. The jumbo acetabular component for acetabular revision: Curtain Calls and Caveats.

    PubMed

    Lachiewicz, P F; Watters, T S

    2016-01-01

    The 'jumbo' acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. ©2016 The British Editorial Society of Bone & Joint Surgery.

  20. [Acetabuloplasty in cerebral palsy patients].

    PubMed

    Schejbalová, A; Chládek, P

    2007-12-01

    Acetabuloplasty as an isolated surgical procedure is one of the options allowing for hip joint realignment in cerebral palsy patients. Also, it is often involved in combined techniques used for hip joint reconstruction. In the years 2004-2005, 20 cerebral palsy patients, aged from 4 to 13 years, were indicated for acetabuloplasty. The group included children with varying degrees of locomotor disability, ranging from inability even to crawl to ability to move without support (stages 2 to 7 on the Vojta scale). Clinical and X-ray findings were evaluated at 2 and 6 months after surgical treatment and then every 6 months of follow- up. The X-ray finding was described by means of CE angle (Wiberg) values and hip migration percentage. Of 21 hips (in 20 patients) treated by acetabuloplasty in our modification during the two years, one developed recurrent dorsal dislocation which was possible to deal with by conservative treatment. All hips pre-operatively categorized as group B or group C were post-operatively assessed as group A hips. Subsequent migration of the acetabulum occurred within a year in two patients with distinct original asymmetry. Surgery on bones comprising the hip joint in cerebral palsy patients is indicated according to the degree of lateral migration and changes in hip joint geometry involving the proximal femur or pelvis, or in combination with open reduction. Acetabuloplasty is indicated as an isolated procedure or as part of combined techniques leading to a better coverage of the hip joint. It is recommended for children up to 10 years of age, but also older ones, in whom the flexibility of child bones enables us to do without internal osteosynthesis. Acetabuloplasty is indicated as an isolated surgical procedure for hip joint subluxation in cerebral palsy children. It has no adverse effects on hip abductors that, in cerebral palsy patients, are 85 % insufficient. It improves hip joint symmetry and helps to avoid more demanding reconstructive or palliative procedures. Key words: cerebral palsy, acetabuloplasty, lateral migration.

  1. 5. Recent advances in sports medicine.

    PubMed

    Brukner, Peter D; Crossley, Kay M; Morris, Hayden; Bartold, Simon J; Elliott, Bruce

    2006-02-20

    New research has changed our perception and management of common injuries. Magnetic resonance imaging and arthroscopy of the hip have shown that labral injuries, chondral injuries, rim lesions, synovitis and tears of the ligament teres are common causes of hip, groin and low-back pain. Hip arthroscopy is used both as a diagnostic and therapeutic tool; it has been shown to be of benefit in recent traumatic labral injury, but disappointing in the management of chronic hip pain (which may be associated with degenerative change, and chondral lesions of the acetabulum). The McConnell multimodal physiotherapy regimen is effective in treating patellofemoral pain. Anterior cruciate ligament rupture is three to five times more common in women, but neuromuscular training appears to decrease its incidence. Patellar tendon and hamstring grafts appear to be equally effective in anterior cruciate ligament reconstruction. Articular cartilage defects remain a significant problem, and the efficacy of treatments such as autologous chondrocyte implantation is still unclear.

  2. Adverse Outcomes in Infantile Bilateral Developmental Dysplasia of the Hip.

    PubMed

    Morbi, Abigail H M; Carsi, Belen; Gorianinov, Vitalli; Clarke, Nicholas M P

    2015-01-01

    It is believed that bilateral developmental dysplasia of the hip (DDH) has poorer outcomes with higher rates of avascular necrosis (AVN) and reintervention, compared with unilateral DDH. However, there is limited evidence in the literature, with few studies looking specifically at bilateral cases. A retrospective review of 36 patients (72 hips) with >4 years of follow-up. Patient population included surgically treated DDH including late presentations and failures of conservative treatment. The dislocated hips underwent either simultaneous closed or 1 open and 1 closed, or sequential open reduction. AVN and secondary procedures were used as endpoints for analysis as well as clinical and radiologic outcomes. At the last follow-up, 33% of hips had radiologic signs of AVN. Those hips that had no ossific nucleus (ON) at the time of surgery had an odds ratio of developing AVN of 3.05 and a statistically significant association between the 2 variables, whereas open/closed or simultaneous/sequential reduction did not increase the risk for AVN. In addition, 45.8% of those hips required further surgery. The estimated odds ratio of needing additional surgery after simultaneous reduction was 4.04. Clinically, 79.2% of the hips were graded as McKay I, whereas radiologically only 38.8% were Severin I. The AVN rate in bilateral DDH treated surgically is greater than the rate noted in unilateral cases from the same institution undergoing identical protocols. There was no difference in AVN rates between simultaneous and sequential or between the first and second hip to be sequentially reduced. Presence of ON decreases the risk for AVN, suggesting that in bilateral cases, awaiting the appearance of the ON is an important tool to reduce the incidence of AVN. IV.

  3. Short-term clinical experience with hip resurfacing arthroplasty.

    PubMed

    Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna

    2007-01-01

    This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.

  4. Hip pathology in Majewski osteodysplastic primordial dwarfism type II.

    PubMed

    Karatas, Ali F; Bober, Michael B; Rogers, Kenneth; Duker, Angela L; Ditro, Colleen P; Mackenzie, William G

    2014-09-01

    Majewski osteodysplastic primordial dwarfism type II (MOPDII) is characterized by severe prenatal and postnatal growth failure with microcephaly, characteristic skeletal dysplasia, an increased risk for cerebrovascular disease, and insulin resistance. MOPDII is caused by mutations in the pericentrin (PCNT) gene and is inherited in an autosomal-recessive manner. This study aimed to determine the incidence of hip pathology in patients with molecularly confirmed MOPDII and to describe the functional outcomes of surgical treatment. Thirty-three enrolled patients had a clinical diagnosis of MOPDII. Biallelic PCNT mutations or absent pericentrin protein was confirmed in 25 of these patients. Twelve patients (7 female) had appropriate clinical and radiographic records at this institution and were included in this study. The data collected included age at presentation, age at surgery, sex, body weight and height, weight-bearing status at diagnosis, and the clinical examination. Four patients (31%) had coxa vara: 3 unilateral and 1 bilateral. Three unilateral patients had in situ pinning at a mean age 4 years. The patient with bilateral coxa vara had valgus osteotomy at the age of 5 years. Two children had bilateral hip dysplasia and subluxation with no surgery. One patient had bilateral developmental hip dislocations. The patient was treated by open reduction-spica cast and 2 years after surgery, coxa valga was noted. Another patient was diagnosed at an age of 12 years with bilateral avascular necrosis of the hips. Four patients did not have hip pathology. Hip pathology is common among children with MOPDII; coxa vara is the most frequent diagnosis. Routine clinical and radiographic hip evaluation is important. The capital femoral epiphysis appears to slip down along the shaft, giving the appearance of a proximal femoral epiphysiolysis. A hip diagnosed with slipped capital femoral epiphysis in early life may progress to severe coxa vara. Level IV.

  5. Adult Hip Flexion Contracture due to Neurological Disease: A New Treatment Protocol—Surgical Treatment of Neurological Hip Flexion Contracture

    PubMed Central

    Nicodemo, Alberto; Arrigoni, Chiara; Bersano, Andrea; Massè, Alessandro

    2014-01-01

    Congenital, traumatic, or extrinsic causes can lead people to paraplegia; some of these are potentially; reversible and others are not. Paraplegia can couse hip flexion contracture and, consequently, pressure sores, scoliosis, and hyperlordosis; lumbar and groin pain are strictly correlated. Scientific literature contains many studies about children hip flexion related to neurological diseases, mainly caused by cerebral palsy; only few papers focus on this complication in adults. In this study we report our experience on surgical treatment of adult hip flexion contracture due to neurological diseases; we have tried to outline an algorithm to choose the best treatment avoiding useless or too aggressive therapies. We present 5 cases of adult hips flexion due to neurological conditions treated following our algorithm. At 1-year-follow-up all patients had a good clinical outcome in terms of hip range of motion, pain and recovery of walking if possible. In conclusion we think that this algorithm could be a good guideline to treat these complex cases even if we need to treat more patients to confirm this theory. We believe also that postoperation physiotherapy it is useful in hip motility preservation, improvement of muscular function, and walking ability recovery when possible. PMID:24707293

  6. Adult Hip Flexion Contracture due to Neurological Disease: A New Treatment Protocol-Surgical Treatment of Neurological Hip Flexion Contracture.

    PubMed

    Nicodemo, Alberto; Arrigoni, Chiara; Bersano, Andrea; Massè, Alessandro

    2014-01-01

    Congenital, traumatic, or extrinsic causes can lead people to paraplegia; some of these are potentially; reversible and others are not. Paraplegia can couse hip flexion contracture and, consequently, pressure sores, scoliosis, and hyperlordosis; lumbar and groin pain are strictly correlated. Scientific literature contains many studies about children hip flexion related to neurological diseases, mainly caused by cerebral palsy; only few papers focus on this complication in adults. In this study we report our experience on surgical treatment of adult hip flexion contracture due to neurological diseases; we have tried to outline an algorithm to choose the best treatment avoiding useless or too aggressive therapies. We present 5 cases of adult hips flexion due to neurological conditions treated following our algorithm. At 1-year-follow-up all patients had a good clinical outcome in terms of hip range of motion, pain and recovery of walking if possible. In conclusion we think that this algorithm could be a good guideline to treat these complex cases even if we need to treat more patients to confirm this theory. We believe also that postoperation physiotherapy it is useful in hip motility preservation, improvement of muscular function, and walking ability recovery when possible.

  7. Hip resurfacing: a large, US single-surgeon series.

    PubMed

    Brooks, P J

    2016-01-01

    Hip resurfacing has been proposed as an alternative to traditional total hip arthroplasty in young, active patients. Much has been learned following the introduction of metal-on-metal resurfacing devices in the 1990s. The triad of a well-designed device, implanted accurately, in the correct patient has never been more critical than with these implants. Following Food and Drug Administration approval in 2006, we studied the safety and effectiveness of one hip resurfacing device (Birmingham Hip Resurfacing) at our hospital in a large, single-surgeon series. We report our early to mid-term results in 1333 cases followed for a mean of 4.3 years (2 to 5.7) using a prospective, observational registry. The mean patient age was 53.1 years (12 to 84); 70% were male and 91% had osteoarthritis. Complications were few, including no dislocations, no femoral component loosening, two femoral neck fractures (0.15%), one socket loosening (0.08%), three deep infections (0.23%), and three cases of metallosis (0.23%). There were no destructive pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship in males under the age of 50 was 100%. We believe this is the largest United States series of a single surgeon using a single resurfacing system. ©2016 The British Editorial Society of Bone & Joint Surgery.

  8. High-Riding Congenital Hip Dislocation: THA With Unilateral vs Bilateral Transverse Femoral Shortening Osteotomy.

    PubMed

    Can, Ata; Sarikaya, Ilker A; Yontar, Necip S; Erdogan, Ayse O; Gorgun, Baris; Erdogan, Fahri

    2018-05-01

    We argue that 1-stage bilaterally total hip arthroplasty (THA) could be acceptable in bilateral coxarthrosis because of high-riding developmental dysplasia of the hip (DDH). Sixty-nine cases (51 patients) of high-riding DDH in patients who underwent THA from 2010 to 2013 were reviewed. Patients were divided into 2 groups: unilateral (group 1) and 1-stage bilateral surgery (group 2). The clinical measurements were the visual analog scale and Harris Hip Score. The average follow-up was 37.3 months for group 1 and 38.8 months for group 2. The hospital stay time was 5.2 days in group 1 and 6.2 days in group 2 (P = .334). The mean Harris Hip Score and visual analog scale score were improved significantly after surgery for both groups, and there was no statistically significant difference (P = .988). There was no difference between groups 1 and 2 in terms of complications (P = .137). Our data confirm that 1-stage bilateral transverse osteotomy with THA is an effective method as unilateral and it does not increase the length of patients' hospital stays and features a low risk of postoperative complications in the treatment of patients with high-riding DDH. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model

    PubMed Central

    Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof

    2014-01-01

    Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672

  10. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    PubMed

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p < 0.02) in those undergoing revision replacement of the hip, and the mean Hospital for Special Surgery knee score increased to 75 points (70 to 80; p < 0.01) in those undergoing revision replacement of the knee. A single-stage revision following fungal peri-prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  11. Secondary infection of haematoma following closed acromioclavicular joint dislocation

    PubMed Central

    Dupley, Leanne; Berg, Andrew James; Mohil, Randeep

    2016-01-01

    An unusual case of a patient presenting with a large infected haematoma following a traumatic grade II acromioclavicular joint dislocation is reported. Diagnosis of this rare complication, of an otherwise common self-limiting injury, was delayed until 19 days postinjury despite several presentations during this time with worsening swelling and pain. The patient was found to have significant tissue destruction by the time washout was performed and required multiple procedures to treat the infection. This case highlights the need for a high index of suspicion for complications, even following common self-limiting injuries, when patients represent with symptoms that do not fit the usual natural history of the condition, particularly if they have risk factors for bleeding and infection. PMID:26786526

  12. Knee Dislocations

    PubMed Central

    Schenck, Robert C.; Richter, Dustin L.; Wascher, Daniel C.

    2014-01-01

    Background: Traumatic knee dislocation is becoming more prevalent because of improved recognition and increased exposure to high-energy trauma, but long-term results are lacking. Purpose: To present 2 cases with minimum 20-year follow-up and a review of the literature to illustrate some of the fundamental principles in the management of the dislocated knee. Study Design: Review and case reports. Methods: Two patients with knee dislocations who underwent multiligamentous knee reconstruction were reviewed, with a minimum 20-year follow-up. These patients were brought back for a clinical evaluation using both subjective and objective measures. Subjective measures include the following scales: Lysholm, Tegner activity, visual analog scale (VAS), Short Form–36 (SF-36), International Knee Documentation Committee (IKDC), and a psychosocial questionnaire. Objective measures included ligamentous examination, radiographic evaluation (including Telos stress radiographs), and physical therapy assessment of function and stability. Results: The mean follow-up was 22 years. One patient had a vascular injury requiring repair prior to ligament reconstruction. The average assessment scores were as follows: SF-36 physical health, 52; SF-36 mental health, 59; Lysholm, 92; IKDC, 86.5; VAS involved, 10.5 mm; and VAS uninvolved, 2.5 mm. Both patients had excellent stability and were functioning at high levels of activity for their age (eg, hiking, skydiving). Both patients had radiographic signs of arthritis, which lowered 1 subject’s IKDC score to “C.” Conclusion: Knee dislocations have rare long-term excellent results, and most intermediate-term studies show fair to good functional results. By following fundamental principles in the management of a dislocated knee, patients can be given the opportunity to function at high levels. Hopefully, continued advances in the evaluation and treatment of knee dislocations will improve the long-term outcomes for these patients in the future. PMID:26535332

  13. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    PubMed

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  14. Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.

    PubMed

    Pelayo-de Tomás, J M; Novoa-Parra, C; Gómez-Barbero, P

    Symptomatic cobalt toxicity from a failed total hip replacement is a rare, but devastating complication. Potential clinical findings include cardiomyopathy, hypothyroidism, skin rash, visual and hearing impairment, polycythaemia, weakness, fatigue, cognitive impairment, and neuropathy. The case is presented of a 74year-old man in whom, after a ceramic-ceramic replacement and two episodes of prosthetic dislocation, it was decided to replace it with a polyethylene-metal total hip arthroplasty (THA). At 6months after the revision he developed symptoms of cobalt toxicity, confirmed by analytical determination (serum cobalt level=651.2μg/L). After removal of the prosthesis, the levels of chromium and cobalt in blood and urine returned to normal, with the patient currently being asymptomatic. It is recommended to use a new ceramic on ceramic bearing at revision, in order to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. [Results and experiences of conversion of hip arthrodesis ].

    PubMed

    Schuh, A; Zeiler, G; Werber, S

    2005-03-01

    With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.

  16. [Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].

    PubMed

    Hrubina, M; Skoták, M

    2012-01-01

    Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.

  17. Acute quadriplegia following closed traction reduction of a cervical facet dislocation in the setting of ossification of the posterior longitudinal ligament: case report.

    PubMed

    Wimberley, David W; Vaccaro, Alexander R; Goyal, Nitin; Harrop, James S; Anderson, D Greg; Albert, Todd J; Hilibrand, Alan S

    2005-08-01

    A case report of acute quadriplegia resulting from closed traction reduction of traumatic bilateral cervical facet dislocation in a 54-year-old male with concomitant ossification of the posterior longitudinal ligament (OPLL). To report an unusual presentation of a spinal cord injury, examine the approach to reversal of the injury, and review the treatment and management controversies of acute cervical facet dislocations in specific patient subgroups. The treatment of acute cervical facet dislocations is an area of ongoing controversy, especially regarding the question of the necessity of advanced imaging studies before closed traction reduction of the dislocated cervical spine. The safety of an immediate closed, traction reduction of the cervical spine in awake, alert, cooperative, and appropriately select patients has been reported in several studies. To date, there have been no permanent neurologic deficits resulting from awake, closed reduction reported in the literature. A case of temporary, acute quadriplegia with complete neurologic recovery following successful closed traction reduction of a bilateral cervical facet dislocation in the setting of OPLL is presented. The clinical neurologic examination, radiographic, and advanced imaging studies before and after closed, traction reduction of a cervical facet dislocation are evaluated and discussed. A review of the literature regarding the treatment of acute cervical facet dislocations is presented. Radiographs showed approximately 50% subluxation of the fifth on the sixth cervical vertebrae, along with computerized tomography revealing extensive discontinuous OPLL. The cervical facet dislocation was successfully reduced with an awake, closed traction reduction, before magnetic resonance imaging (MRI) evaluation. The patient subsequently had acute quadriplegia develop, with the ensuing MRI study illustrating severe spinal stenosis at the C5, C6 level as a result of OPLL or a large extruded disc herniation. Following an immediate anterior decompression and a posterior stabilization procedure, the patient regained full motor and sensory function. This case report highlights the advantages and shows some safety concerns regarding immediate, closed traction reduction of cervical facet dislocation with real-time neural monitoring in an awake, alert, oriented, and appropriately select patient before MRI studies in the setting of preexisting central stenosis from OPLL.

  18. Treatment of athletes with symptomatic intra-articular hip pathology and athletic pubalgia/sports hernia: a case series.

    PubMed

    Larson, Christopher M; Pierce, Bradley R; Giveans, M Russell

    2011-06-01

    The purpose of the study was to evaluate the results of surgical treatment in athletes with associated intra-articular hip pathology and extra-articular sports pubalgia. Between December 2003 and September 2009, 37 hips (mean patient age, 25 years) were diagnosed with both symptomatic athletic pubalgia and symptomatic intra-articular hip joint pathology. There were 8 professional athletes, 15 collegiate athletes, 5 elite high school athletes, and 9 competitive club athletes. Outcomes included an evaluation regarding return to sports and modified Harris Hip Score, Short Form 12 score, and visual analog scale score. We evaluated 37 hips at a mean of 29 months (range, 12 to 78 months) after the index surgery. Thirty-one hips underwent thirty-five athletic pubalgia surgeries. Hip arthroscopy was performed in 32 hips (30 cases of femoroacetabular impingement treatment, 1 traumatic labral tear, and 1 borderline dysplasia). Of 16 hips that had athletic pubalgia surgery as the index procedure, 4 (25%) returned to sports without limitations, and 11 (69%) subsequently had hip arthroscopy at a mean of 20 months after pubalgia surgery. Of 8 hips managed initially with hip arthroscopy alone, 4 (50%) returned to sports without limitations, and 3 (43%) had subsequent pubalgia surgery at a mean of 6 months after hip arthroscopy. Thirteen hips had athletic pubalgia surgery and hip arthroscopy at one setting. Concurrent or eventual surgical treatment of both disorders led to improved postoperative outcomes scores (P < .05) and an unrestricted return to sporting activity in 89% of hips (24 of 27). When surgery only addressed either the athletic pubalgia or intra-articular hip pathology in this patient population, outcomes were suboptimal. Surgical management of both disorders concurrently or in a staged manner led to improved postoperative outcomes scoring and an unrestricted return to sporting activity in 89% of hips. Level IV, therapeutic case series. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Congenital cutis laxa with ligamentous laxity and delayed development, Dandy-Walker malformation and minor heart and osseous defects.

    PubMed

    Biver, A; De Rijcke, S; Toppet, V; Ledoux-Corbusier, M; Van Maldergem, L

    1994-06-01

    We present a female infant exhibiting congenital cutis laxa with retardation of growth and motor development, ligamentous laxity and congenital dislocation of the hips. This connective tissue disorder was associated with Dandy-Walker malformation, atrial and ventricular defect and minor bone abnormalities including multiple wormian bones, abnormal tubulation of long bones and absent twelfth pair of ribs. This association is believed to be unique.

  20. 77 FR 19293 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ... as rheumatoid arthritis; c. Correction of functional deformity; and, d. Revision procedures where... the hip (DDH); or b. Inflammatory arthritis such as rheumatoid arthritis. Resurfacing systems are... degenerative joint disease (NIDJD) such as osteoarthritis, avascular necrosis, post-traumatic arthritis...

  1. [Comparison of core decompression with stem cell transplantation and tantalum rod implanting in treating stage II non-traumatic osteonecrosis of femoral head].

    PubMed

    He, Bang-Jian; Li, Ju; Lyu, Yi; Tong, Pei-Jian

    2016-12-25

    To compare clinical effects of core decompression with stem cell transplantation and tantalum rod implanting in treating stage II non-traumatic osteonecrosis of femoral head. From March 2012 to September 2012, 45 patients(55 hips)with stage ARCO II non-traumatic osteonecrosis of femoral head were treated and divided into core decompression with stem cell transplantation group(group A) and tantalum rod implanting group(group B) according to number table. In group A, there were 23 cases(28 hips) , including 12 males and 11 females aged from 23 to 51 years old with an average of (36.87±9.52) years, the courses of disease ranged from 2 to 28 months with an average of (17.13±7.74) months, preoperative Harris score was for 35 to 70 with an average of(54.74±11.81), treated with core decompression with stem cell transplantation. In group B, there were 22 cases(27 hips), including 11 males and 11 females aged from 26 to 46 years old with an average of (35.59±7.39) years, the courses of disease ranged from 3 to 26 months with an average of(16.00±7.46) months, preoperative Harris score was for 35 to 76 with an average of (57.18±12.95), treated with core tantalum rod implanting. Operative time, blood loss, hospital stays, hospitalization expenses were observed and compared after treatment between two groups, the clinical effects were evaluated according to Harris criteria. All patients were followed up from 6 to 12 months with an average of 10.8 months. There were significant difference in hospitalization expenses between two groups( P <0.05), while there was no significant statistical difference in blood loss and hospital stay ( P >0.05). At the final following-up, Harris score in group A was(83.04±8.97), 6 cases obtained excellent results, 14 good, 2 good and 1 poor;while Harris score in group A was(84.41±9.94), and 9 cases obtained excellent results, 9 good, 3 good and 1 poor; there was no statistical meaning differences between two groups( P >0.05). Core decompression with stem cell transplantation and tantalum rod implanting could both improve function of hip joint, while core decompression with stem cell transplantation had advantages of shorter operation time, less cost, and higher potency ratio. It is suitable for stage ARCO II non-traumatic femoral head necrosis.

  2. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    PubMed

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  3. Sports Injuries about the Hip: What the Radiologist Should Know.

    PubMed

    Hegazi, Tarek M; Belair, Jeffrey A; McCarthy, Eoghan J; Roedl, Johannes B; Morrison, William B

    2016-10-01

    Injuries of the hip and surrounding structures represent a complex and commonly encountered scenario in athletes, with improper diagnosis serving as a cause of delayed return to play or progression to a more serious injury. As such, radiologists play an essential role in guiding management of athletic injuries. Familiarity with hip anatomy and the advantages and limitations of various imaging modalities is of paramount importance for accurate and timely diagnosis. Magnetic resonance (MR) imaging is often the modality of choice for evaluating many of the injuries discussed, although preliminary evaluation with conventional radiography and use of other imaging modalities such as ultrasonography (US), computed tomography, and bone scintigraphy may be supplementary or preferred in certain situations. Stress fractures, thigh splints, and posterior hip dislocations are important structural injuries to consider in the athlete, initially imaged with radiographs and often best diagnosed with MR imaging. Apophyseal injuries are particularly important to consider in young athletes and may be acute or related to chronic repetitive microtrauma. Femoroacetabular impingement has been implicated in development of labral tears and cartilage abnormalities. Tear of the ligamentum teres is now recognized as a potential cause of hip pain and instability, best evaluated with MR arthrography. Greater trochanteric pain syndrome encompasses a group of conditions leading to lateral hip pain, with US playing an increasingly important role for both evaluation and image-guided treatment. Muscle injuries and athletic pubalgia are common in athletes. Lastly, snapping hip syndrome and Morel-Lavallée lesions are two less common but nonetheless important considerations. © RSNA, 2016.

  4. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

    PubMed

    Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan

    2015-10-01

    Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.

  5. Application of individually performed acrylic cement spacers containing 5% of antibiotic in two-stage revision of hip and knee prosthesis due to infection.

    PubMed

    Babiak, Ireneusz

    2012-07-03

    Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.

  6. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    PubMed

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  7. Thermo-mechanical process for treatment of welds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malik, R K

    1980-03-01

    Benefits from thermo-mechanical processing (TMP) of austenitic stainless steel weldments, analogous to hot isostatic pressing (HIP) of castings, most likely result from compressive plastic deformation, enhanced diffusion, and/or increased dislocation density. TMP improves ultrasonic inspectability of austenitic stainless steel welds owing to: conversion of cast dendrites into equiaxed austenitic grains, reduction in size and number of stringers and inclusions, and reduction of delta ferrite content. TMP induces structural homogenization and healing of void-type defects and thus contributes to an increase in elongation, impact strength, and fracture toughness as well as a significant reduction in data scatter for these properties. Anmore » optimum temperature for TMP or HIP of welds is one which causes negligible grain growth and an acceptable reduction in yield strength, and permits healing of porosity.« less

  8. Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component.

    PubMed

    John, Thomas K; Ghosh, Gaurav; Ranawat, Chitranjan S; Ranawat, Amar S; Meftah, Morteza

    2015-12-01

    The purpose of this study was to assess the durability of a non-cemented, hemispherical rim-fit, hydroxyapatite coated cup with a highly cross-linked polyethylene in 223 total hip arthroplasties. At 6-years follow-up (range, 5-9), there were no cup revisions for osteolysis or loosening. Radiologic evidence of osseointegration was based on presence of Stress Induced Reactive Cancellous Bone and radial trabeculae, seen in 47% and 93% of cups, respectively; both were most prevalent in Zone 1. There was no interference demarcation in any zones. Two cups were revised (0.9%): one for dislocation and another for infection. The Kaplan-Meier survivorship for cup revision for any failure (infection, dislocation) was 99% and for mechanical failure (osteolysis, loosening) was 100%. This design has excellent safety, efficacy and durability. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    PubMed

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.

  10. Comparison of outcome measures and complication rates following three different approaches for primary total hip arthroplasty: a pragmatic randomised controlled trial.

    PubMed

    Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong

    2018-01-08

    Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.

  11. Glenohumeral instability and rotator cuff tear.

    PubMed

    Porcellini, Giuseppe; Caranzano, Francesco; Campi, Fabrizio; Pellegrini, Andrea; Paladini, Paolo

    2011-12-01

    The prevalence of rotator cuff tears after traumatic dislocation increases with advancing age, a likely consequence of the age-associated deterioration of the structure and mechanical properties of the tendons of the rotator cuff. These are the effective stabilizers of the glenohumeral joint, compressing the humeral head in the 3-dimensional concavity of the glenohumeral joint. It is impossible to establish whether a lesion of the capsular-labrum complex or of the rotator cuff causes or follows a dislocation, regardless of whether it is anterior or posterior. A peripheral nerve or a brachial plexus injury can be associated with tendon lesion and instability, developing the "terrible triad" of the shoulder. Both conservative and surgical management are possible, and surgeons must choose the most appropriate management modality according to the biologic age, functional demands, and type of lesion.

  12. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty

    PubMed Central

    2012-01-01

    Background and purpose Coating of acetabular revision implants with hydroxyapatite (HA) has been proposed to improve ingrowth and stability. We investigated whether HA coating of revision cups can reduce the risk of any subsequent re-revision. Methods We studied uncemented cups either with or without HA coating that were used at a primary acetabular revision and registered in the Swedish Hip Arthroplasty Register (SHAR). 2 such cup designs were identified: Harris-Galante and Trilogy, both available either with or without HA coating. These cups had been used as revision components in 1,780 revisions of total hip arthroplasties (THA) between 1986 and 2009. A Cox proportional hazards model including the type of coating, age at index revision, sex, cause of cup revision, cup design, the use of bone graft at the revision procedure, and the type of cup fixation at primary THA were used to calculate adjusted risk ratios (RRs with 95% CI) for re-revision for any reason or due to aseptic loosening. Results 71% of the cups were coated with HA and 29% were uncoated. At a mean follow-up time of 6.9 (0–24) years, 159 (9%) of all 1,780 cups had been re-revised, mostly due to aseptic loosening (5%), dislocation (2%), or deep infection (1%). HA coating had no significant influence on the risk of re-revision of the cup for any reason (RR = 1.4, CI: 0.9–2.0) or due to aseptic loosening (RR = 1.1, 0.6–1.9). In contrast, HA coating was found to be a risk factor for isolated liner re-revision for any reason (RR = 1.8, CI: 1.01–3.3). Age below 60 years at the index cup revision, dislocation as the cause of the index cup revision, uncemented cup fixation at primary THA, and use of the Harris-Galante cup also increased the risk of re-revision of the cup. In separate analyses in which isolated liner revisions were excluded, bone grafting was found to be a risk factor for re-revision of the metal shell due to aseptic loosening (RR = 2.1, CI: 1.05–4.2). Interpretation We found no evidence to support the notion that HA coating improves the performance of the 2 studied cup designs in revision arthroplasty. In contrast, patient-related factors such as younger age and dislocation as the reason for cup revision, and technical factors such as the choice of revision cup were found to influence the risk of subsequent re-revision of the cup. The reason for inferior results after revision of uncemented cups is not known, but it is possible that these hips more often had pronounced bone loss at the index cup revision. PMID:22937978

  13. Changes in surgical procedures for acromioclavicular joint dislocation over the past 30 years.

    PubMed

    Takase, Katsumi; Yamamoto, Kengo

    2013-10-01

    Generally, surgical treatment is recommended for Rockwood type 5 traumatic acromioclavicular joint dislocations. Since 1980, the authors have performed the modified Dewar procedure, the modified Cadenat procedure, and anatomical reconstruction of the coracoclavicular ligaments for this injury. The goal of this study was to determine the ideal surgical procedure for acromioclavicular joint dislocations by comparing these 3 procedures. The modified Dewar procedure was performed on 55 patients (Dewar group), the modified Cadenat procedure was performed on 73 patients (Cadenat group), and anatomical reconstruction of the coracoclavicular ligaments was performed on 11 patients (reconstruction group). According to the UCLA scoring system, therapeutic results averaged 27.3 points in the Dewar group, 28.2 in the Cadenat group, and 28.4 in the reconstruction group. The incidence of residual subluxation or dislocation in the acromioclavicular joint was evaluated at final radiographic follow-up. Subluxation occurred in 21 patients in the Dewar group, 18 in the Cadenat group, and 3 in the reconstruction group. Dislocation occurred in 3 patients in the Dewar group. Osteoarthritic changes in the acromioclavicular joint occurred in 20 patients in the Dewar group, 9 in the Cadenat group, and 1 in the reconstruction group. The modified Cadenat procedure can provide satisfactory therapeutic results and avoid postoperative failure or loss of reduction compared with the modified Dewar procedure. However, the modified Cadenat procedure does not anatomically restore the coracoclavicular ligaments. Anatomic restoration of both coracoclavicular ligaments can best restore acromioclavicular joint function. Copyright 2013, SLACK Incorporated.

  14. Reduction of metallosis in hip implant using thin film coating

    NASA Astrophysics Data System (ADS)

    Rajeshshyam, R.; Chockalingam, K.; Gayathri, V.; Prakash, T.

    2018-04-01

    Hip implant finds its emerging attraction due to it continuous demand over the years. The hip implants (femoral head) and acetabulum cup) mainly fabricated by metals such as stainless steel, cobalt chrome and titanium alloys, other than that ceramics and polyethylene have been used. The metal-on-metal hip implant was found to be best implant material for most of the surgeons due to its high surface finish, low wear rate and low chance of dislocation from its position after implanting. Where in metal based hip implant shows less wear rate of 0.01mm3/year. Metal-on-metal implant finds its advantage over other materials both in its mechanical and physical stability against human load. In M-O-M Cobalt- chromium alloys induce metal allergy. The metal allergy (particulate debris) that is generated by wear, fretting, fragmentation and which is unavoidable when a prosthesis is implanted, can induce an inflammatory reaction in some circumstances. The objectives of this research to evaluate thin film coating with Nano particle additives to reduce the wear leads to regarding metal ion release. Experimental results reveals that thin film Sol-Gel coating with 4wt. % of specimen reduced the cobalt and chromium ion release and reduces the wear rate. Wear rate reduced by 98% for 4wt. % graphene in 20N and 95% for 4wt. % graphene in 10N.

  15. Relatively High Complication and Revision Rates of the Mayo® Metaphysical Conservative Femoral Stem in Young Patients.

    PubMed

    Rutenberg, Tal Frenkel; Warshevski, Yaniv; Gold, Aviram; Shasha, Nadav; Snir, Nimrod; Chechik, Ofir; Dolkart, Oleg; Eilig, Dynai; Herman, Amir; Rath, Ehud; Kramer, Moti; Drexler, Michael

    2018-05-08

    The Mayo metaphysical conservative femoral stem (Zimmer, Warsaw, Indiana) is a wedge-shaped implant designed to transfer loads proximally, reduce femoral destruction, and enable the preservation of bone stock in the proximal femur. Thus, it is a potentially preferred prosthesis for active, non-elderly patients who may require additional future surgeries. This retrospective case study analyzed the outcomes of consecutive patients who underwent total hip replacements with this stem between May 2001 and February 2013. All patients underwent clinical assessment, radiological evaluation for the presence and development of radiolucent lines, and functional assessment (numerical analog scale, Harris hip score, and Short Form-12 questionnaire). Ninety-five hips (79 patients) were available for analysis. The patients' mean age was 43 years (range, 18-64 years), and the mean follow-up was 97 months (range, 26.9-166 months). The postoperative clinical assessments and functional assessments revealed significant improvements. Sixteen patients (20.3%) had 18 orthopedic complications, the most common of which were an intraoperative femoral fracture and implant dislocation requiring revision surgeries in 10 hips (10.5%). Radiological analysis revealed evidence of femoral remodeling in 64 (67.4%) implants, spot welds (neocortex) in 35 (36.8%), and osteolysis in 3 (3.2%). These results suggest that the conservative hip femoral implant has an unacceptable complication rate for non-elderly patients. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.

  16. HiL simulation in biomechanics: a new approach for testing total joint replacements.

    PubMed

    Herrmann, Sven; Kaehler, Michael; Souffrant, Robert; Rachholz, Roman; Zierath, János; Kluess, Daniel; Mittelmeier, Wolfram; Woernle, Christoph; Bader, Rainer

    2012-02-01

    Instability of artificial joints is still one of the most prevalent reasons for revision surgery caused by various influencing factors. In order to investigate instability mechanisms such as dislocation under reproducible, physiologically realistic boundary conditions, a novel test approach is introduced by means of a hardware-in-the-loop (HiL) simulation involving a highly flexible mechatronic test system. In this work, the underlying concept and implementation of all required units is presented enabling comparable investigations of different total hip and knee replacements, respectively. The HiL joint simulator consists of two units: a physical setup composed of a six-axes industrial robot and a numerical multibody model running in real-time. Within the multibody model, the anatomical environment of the considered joint is represented such that the soft tissue response is accounted for during an instability event. Hence, the robot loads and moves the real implant components according to the information provided by the multibody model while transferring back the position and resisting moment recorded. Functionality of the simulator is proved by testing the underlying control principles, and verified by reproducing the dislocation process of a standard total hip replacement. HiL simulations provide a new biomechanical testing tool for analyzing different joint replacement systems with respect to their instability behavior under realistic movements and physiological load conditions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. [Tumor prostheses : Important in modern revision arthroplasty].

    PubMed

    Hillmann, A; Ipach, I

    2015-05-01

    Due to demographic aging, an increasing number of revision arthroplasty procedures is expected during upcoming years. While the use of a megaprosthesis for bone reconstruction after tumor resection is gold standard, this type of prosthesis still meets with reservation in the field of revision arthroplasty because of numerous risk factors. The purpose of this article is to present the importance of modular megaprostheses in revision arthroplasty, taking into consideration the risks of periprosthetic infection, aseptic loosening, material failure, and hip dislocation. Because of improvements in the field of megaprostheses during the last 30 years, the risks after implantation of this type of prosthesis have significantly decreased. The risk of periprosthetic infection has been reduced about 1/3 by the use of silver surface coating. Improvements in stem design, cement technique, and the additional use of locking screws have minimized the risk of aseptic loosening. Improvements in material composition have reduced the risk of material failure. The risk of hip dislocation could also be minimized by careful tissue preparation and appropriate suture technique. There is no need for the conservative use of megaprostheses in revision arthroplasty. There are many benefits in the use of megaprostheses in multimorbid patients (i.e., reduced operating time, the possibility of early full weight bearing, and a reduced risk of periprosthetic infection by the use of silver surface coating) instead of complex bone reconstruction during revision arthroplasty.

  18. Differential Histopathological and Behavioral Outcomes Eight Weeks after Rat Spinal Cord Injury by Contusion, Dislocation, and Distraction Mechanisms

    PubMed Central

    Chen, Kinon; Liu, Jie; Assinck, Peggy; Bhatnagar, Tim; Streijger, Femke; Zhu, Qingan; Dvorak, Marcel F.; Kwon, Brian K.; Tetzlaff, Wolfram

    2016-01-01

    Abstract The objective of this study was to compare the long-term histological and behavioral outcomes after spinal cord injury (SCI) induced by one of three distinct biomechanical mechanisms: dislocation, contusion, and distraction. Thirty male Sprague-Dawley rats were randomized to incur a traumatic cervical SCI by one of these three clinically relevant mechanisms. The injured cervical spines were surgically stabilized, and motor function was assessed for the following 8 weeks. The spinal cords were then harvested for histologic analysis. Quantification of white matter sparing using Luxol fast blue staining revealed that dislocation injury caused the greatest overall loss of white matter, both laterally and along the rostrocaudal axis of the injured cord. Distraction caused enlarged extracellular spaces and structural alteration in the white matter but spared the most myelinated axons overall. Contusion caused the most severe loss of myelinated axons in the dorsal white matter. Immunohistochemistry for the neuronal marker NeuN combined with Fluoro Nissl revealed that the dislocation mechanism resulted in the greatest neuronal cell losses in both the ventral and dorsal horns. After the distraction injury mechanism, animals displayed no recovery of grip strength over time, in contrast to the animals subjected to contusion or dislocation injuries. After the dislocation injury mechanism, animals displayed no improvement in the grooming test, in contrast to the animals subjected to contusion or distraction injuries. These data indicate that different SCI mechanisms result in distinct patterns of histopathology and behavioral recovery. Understanding this heterogeneity may be important for the future development of therapeutic interventions that target specific neuropathology after SCI. PMID:26671448

  19. Diagnosis and management of traumatic cervical central spinal cord injury: A review.

    PubMed

    Epstein, Nancy E; Hollingsworth, Renee

    2015-01-01

    The classical clinical presentation, neuroradiographic features, and conservative vs. surgical management of traumatic cervical central spinal cord (CSS) injury remain controversial. CSS injuries, occurring in approximately 9.2% of all cord injuries, are usually attributed to significant hyperextension trauma combined with congenital/acquired cervical stenosis/spondylosis. Patients typically present with greater motor deficits in the upper vs. lower extremities accompanied by patchy sensory loss. T2-weighted magnetic resonance (MR) scans usually show hyperintense T2 intramedullary signals reflecting acute edema along with ligamentous injury, while noncontrast computed tomography (CT) studies typically show no attendant bony pathology (e.g. no fracture, dislocation). CSS constitute only a small percentage of all traumatic spinal cord injuries. Aarabi et al. found CSS patients averaged 58.3 years of age, 83% were male and 52.4% involved accidents/falls in patients with narrowed spinal canals (average 5.6 mm); their average American Spinal Injury Association (ASIA) motor score was 63.8, and most pathology was at the C3-C4 and C4-C5 levels (71%). Surgery was performed within 24 h (9 patients), 24-48 h (10 patients), or after 48 h (23 patients). In the Brodell et al. study of 16,134 patients with CSS, 39.7% had surgery. In the Gu et al. series, those with CSS and stenosis/ossification of the posterior longitudinal ligament (OPLL) exhibited better outcomes following laminoplasty. Recognizing the unique features of CSS is critical, as the clinical, neuroradiological, and management strategies (e.g. conservative vs. surgical management: early vs. late) differ from those utilized for other spinal cord trauma. Increased T2-weighted MR images best document CSS, while CT studies confirm the absence of fracture/dislocation.

  20. Evaluation of Spine Health and Spine Mechanics in Servicemembers with Traumatic Lower Extremity Amputation or Injury

    DTIC Science & Technology

    2015-10-01

    of proximal compensations (e.g., hip-hiking) to assist with toe clearance (Michaud et al., 2000), or simply because these individuals feel more...related unilateral lower extremity amputation: a long-term survey in a prosthesis center in Iran. Journal of orthopaedic trauma 23(7), 525-530

  1. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    PubMed

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  2. The anteromedial approach to the psoas tendon in patients with cerebral palsy

    PubMed Central

    Poonnoose, Pradeep M.; Palocaren, Thomas

    2007-01-01

    Purpose Release of the psoas tendon for flexion deformity of the hip in children with cerebral palsy has traditionally been performed at the pelvic brim, lateral to the neurovascular bundle, or at its insertion into the lesser trochanter. As the psoas tendon is lateral to the pectineus, the traditional exposure of the tendon through an approach medial to the pectineus is limited by the extent to which the pectineus can be retracted proximally. Technical note We describe the use of the anteromedial approach used for the developmentally dislocated hip to expose the psoas tendon between the pectineus and the neurovascular bundle. This provides a much better visualisation of the tendon as it crosses the superior pubic ramus to its insertion. The use of this approach has not been described in cerebral palsy. PMID:19308518

  3. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

    PubMed

    Murphy, William S; Yun, Ho Hyun; Hayden, Brett; Kowal, Jens H; Murphy, Stephen B

    2018-02-01

    Cup malposition is a common cause of impingement, limitation of ROM, acceleration of bearing wear, liner fracture, and instability in THA. Previous studies of the safe zone based on plain radiographs have limitations inherent to measuring angles from two-dimensional projections. The current study uses CT to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in THA. (1) Does acetabular component orientation, when measured on CT, differ in stable components and those revised for recurrent instability? (2) Do CT data support historic safe zone definitions for component orientation in THA? We identified 34 hips that had undergone revision of the acetabulum for recurrent instability that also had a CT scan of the pelvis between August 2003 and February 2017. We also identified 175 patients with stable hip replacements who also had a CT study for preoperative planning and intraoperative navigation of the contralateral side. For each CT study, one observer analyzed major factors including acetabular orientation, femoral anteversion, combined anteversion (the sum of femoral and anatomic anteversion), pelvic tilt, total offset difference, head diameter, age, sex, and body mass index. These measures were then compared among stable hips, hips with cup revision for anterior instability, and hips with cup revision for posterior instability. We used a clinically relevant measurement of operative anteversion and inclination as opposed to the historic use of radiographic anteversion and inclination. The percentage of unstable hips in the historic Lewinnek safe zone was calculated, and a new safe zone was proposed based on an area with no unstable hips. Anteriorly unstable hips compared with stable hips had higher operative anteversion of the cup (44° ± 12° versus 31° ± 11°, respectively; mean difference, 13°; 95% confidence interval [CI], 5°-21°; p = 0.003), tilt-adjusted operative anteversion of the cup (40° ± 6° versus 26° ± 10°, respectively; mean difference, 14°; 95% CI, 10°-18°; p < 0.001), and combined tilt-adjusted anteversion of the cup (64° ± 10° versus 54° ± 19°, respectively; mean difference, 10°; 95% CI, 1°-19°; p = 0.028). Posteriorly unstable hips compared with stable hips had lower operative anteversion of the cup (19° ± 15° versus 31° ± 11°, respectively; mean difference, -12°; 95% CI, -5° to -18°; p = 0.001), tilt-adjusted operative anteversion of the cup (19° ± 13° versus 26° ± 10°, respectively; mean difference, -8°; 95% CI, -14° to -2°; p = 0.014), pelvic tilt (0° ± 6° versus 4° ± 6°, respectively; mean difference, -4°; 95% CI, -7° to -1°; p = 0.007), and anatomic cup anteversion (25° ± 18° versus 34° ± 12°, respectively; mean difference, -9°; 95% CI, -1° to -17°; p = 0.033). Thirty-two percent of the unstable hips were located in the Lewinnek safe zone (11 of 34; 10 posterior dislocations, one anterior dislocation). In addition, a safe zone with no unstable hips was identified within 43° ± 12° of operative inclination and 31° ± 8° of tilt-adjusted operative anteversion. The current study supports the notion of a safe zone for acetabular component orientation based on CT. However, the results demonstrate that the historic Lewinnek safe zone is not a reliable predictor of future stability. Analysis of tilt-adjusted operative anteversion and operative inclination demonstrates a new safe zone where no hips were revised for recurrent instability that is narrower for tilt-adjusted operative anteversion than for operative inclination. Tilt-adjusted operative anteversion is significantly different between stable and unstable hips, and surgeons should therefore prioritize assessment of preoperative pelvic tilt and accurate placement in operative anteversion. With improvements in patient-specific cup orientation goals and acetabular component placement, further refinement of a safe zone with CT data may reduce the incidence of cup malposition and its associated complications. Level III, diagnostic study.

  4. Quantitative measurement and analysis for detection and treatment planning of developmental dysplasia of the hip

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong

    2009-02-01

    Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).

  5. [Perioperative complications after total hip revision surgery and their predictive factors. A series of 181 consecutive procedures].

    PubMed

    de Thomasson, E; Guingand, O; Terracher, R; Mazel, C

    2001-09-01

    We conducted a retrospective study to assess morbidity and mortality in patients undergoing revision total hip arthroplasty (THA) procedures. Perioperative complications were recorded in 181 revision procedures (162 patients) performed between January 1995 and March 1999 (117 bipolar revisions and 64 acetabular isolated revisions). There were 86 complications (68 patients) leading to 21 new revisions. About half (50/86) were related to the surgical procedure (dislocation, femoral fracture, infection.). Life-threatening complications (3.6%) ended in patient death in 1.6% of the cases. Complications were more frequent in patients with an ASA score=3 (p<0.01) or aged over 75 years (p<0.05). Age was also predictive of femoral misalignment and fracture (p<0.05). Dislocations (8.8%) were observed more frequently in patients who had undergone more than 2 procedures prior to the revision (p<0.05) (4.8% of the dislocations in patients undergoing a first revision procedure and 14.3% in the others). In addition, peroperative blood loss and duration of the procedure were significantly greater in case of bipolar replacement than for isolated acetabular replacement (sigma > 1.96). Our experience and data in the literature point to the important age factor in the development of complications. Preservation of a well-fixed femoral component does not appear to worsen prognosis and leads to fewer complications than bipolar changes. The decision to revise a THA must take into consideration the functional impairment but also the risks inherent in revision procedures, particularly in old patients who have undergone several procedures. Revising the acetabular component alone can be an interesting option if the femoral component remains well-fixed although our follow-up is insufficient to determine whether this attitude provides better long-term outcome than complete biopolar revision. Better patient selection and improved operative technique, in particular in femur preparation, should help reduce morbidity and mortality in this type of procedure.

  6. Case report: Osteonecrosis of the femoral head after hip arthroscopy.

    PubMed

    Scher, Danielle L; Belmont, Philip J; Owens, Brett D

    2010-11-01

    Hip arthroscopy is a common orthopaedic procedure used as a diagnostic and therapeutic tool with a multitude of surgical indications. The complication rate is reportedly between 1.3% and 23.3%. Major complications are related to traction, fluid extravasation, and iatrogenic chondral injury. Although osteonecrosis is a concern with any surgical procedure about the hip, this complication has been primarily a theoretical concern with hip arthroscopy. We report the case of a 24-year-old man who presented with a 2-year history of left hip pain. He underwent hip arthroscopy to include débridement of a torn labrum and removal of a prominent pincer lesion for femoroacetabular impingement. Traction was initiated by applying manual traction to the traction bar until 10 mm of joint distraction was obtained. Traction was removed at 90 minutes. At the 3-month followup, MRI showed osteonecrosis in the subcapital region of the left femoral head. It generally is agreed the magnitude and duration of traction during hip arthroscopy increase the risk of traction-related injuries. Only one previous case of femoral head osteonecrosis associated with hip arthroscopy has been reported, and this may have resulted from the initial traumatic event. Based on anatomic studies, the use of standard arthroscopic portals would not put at risk any dominant normal vascular structures supplying the femoral head. In contrast, the literature shows that femoral head osteonecrosis may develop secondary to a combination of increased intraarticular pressure and traction. We suspect this case of femoral head osteonecrosis after hip arthroscopy was caused by traction used in the procedure.

  7. Acute traumatic open posterolateral dislocation of the ankle without tearing of the tibiofibular syndesmosis ligaments: a case report.

    PubMed

    Demiralp, Bahtiyar; Komurcu, Mahmut; Ozturk, Cagatay; Ozturan, Kutay; Tasatan, Ersin; Erler, Kaan

    2008-01-01

    Pure open dislocation of the ankle, or dislocation not accompanied by rupture of the tibiofibular syndesmosis ligaments or fractures of the malleoli or of the posterior border of the tibia, is an extremely rare injury. A 62-year-old man injured his right ankle in a motor vehicle accident. Besides posterolateral ankle dislocation, there was a 7-cm transverse skin cut on the medial malleolus, and the distal end of the tibia was exposed. After reduction, we made a 2- to 2.5-cm longitudinal incision on the lateral malleolus; the distal fibular fracture was exposed. Two Kirschner wires were placed intramedullary in a retrograde manner, and the fracture was stabilized. The deltoid ligament and the medial capsule were repaired. The tibiofibular syndesmosis ligaments were intact. At the end of postoperative year 1, right ankle joint range of motion had a limit of approximately 5 degrees in dorsiflexion, 10 degrees in plantarflexion, 5 degrees in inversion, and 0 degrees in eversion. The joint appeared normal on radiographs, with no signs of osteoarthritis or calcification. The best result can be obtained with early reduction, debridement, medial capsule and deltoid ligament restoration, and early rehabilitation. Clinical and radiographic features at long-term follow-up also confirm good mobility of the ankle without degenerative change or mechanical instability.

  8. When case report became case series: 45 cases of late traumatic flap complications after laser-assisted in situ keratomileusis and review of Chinese literature.

    PubMed

    Xiao, Jianhe; Jiang, Caihui; Zhang, Maonian; Jiang, Hua; Li, Shiyang; Zhang, Ying

    2014-09-01

    To report 45 cases of late traumatic flap complications after laser-assisted in situ keratomileusis (LASIK) and discuss the continually increasing number of cases in China. A multicentre retrospective survey of eye injuries was carried in 31 military hospitals from January 2006 to December 2011. Detailed information from the medical records of all 92 cases with a history of prior LASIK treatment were collected and summarised, with respect to visual acuity (VA), flap condition, treatment and final outcome. All Chinese publications relevant to late traumatic flap complications in Chinese patients were retrieved and summarised. 92 inpatients (92 eyes) underwent LASIK surgery; 45 of these had traumatic LASIK flap complications. Flap dislocation was the commonest and most needed surgical repair. VA after treatment was good and no statistically significant difference was observed when compared with the 47 cases without flap complications. 109 articles related to late traumatic flap complications after LASIK were retrieved from four Chinese document databases. There were 550 cases of late traumatic flap complications. From 2004, case reports became more common; 10 or more cases were reported in some case series. VA of most cases was good and there was no remarkable vision loss after treatment. Late traumatic flap complications after LASIK have become more frequent in China, although the prognosis of most cases is good. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  9. FUNCTIONAL OUTCOMES OF HIP ARTHROSCOPY IN AN ACTIVE DUTY MILITARY POPULATION UTILIZING A CRITERION-BASED EARLY WEIGHT BEARING PROGRESSION

    PubMed Central

    Jacobs, Jeremy M.; Evanson, J. Richard; Pniewski, Josh; Dickston, Michelle L.; Mueller, Terry; Bojescul, John A.

    2017-01-01

    Introduction Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. Purpose The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Methods Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Results Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants’ functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Conclusions Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level of Evidence Level 4, Case-series PMID:29181261

  10. FUNCTIONAL OUTCOMES OF HIP ARTHROSCOPY IN AN ACTIVE DUTY MILITARY POPULATION UTILIZING A CRITERION-BASED EARLY WEIGHT BEARING PROGRESSION.

    PubMed

    Shaw, K Aaron; Jacobs, Jeremy M; Evanson, J Richard; Pniewski, Josh; Dickston, Michelle L; Mueller, Terry; Bojescul, John A

    2017-10-01

    Hip arthroscopy allows surgeons to address intra-articular pathology of the hip while avoiding more invasive open surgical dislocation. However the post-operative rehabilitation protocols have varied greatly in the literature, with many having prolonged periods of limited motion and weight bearing. The purpose of this study was to describe a criterion-based early weight bearing protocol following hip arthroscopy and investigate functional outcomes in the subjects who were active duty military. Active duty personnel undergoing hip arthroscopy for symptomatic femoroacetabular impingement were prospectively assessed in a controlled environment for the ability to incorporate early postoperative weight-bearing with the following criteria: no increased pain complaint with weight bearing and normalized gait pattern. Modified Harris Hip (HHS) and Hip Outcome score (HOS) were performed preoperatively and at six months post-op. Participants were progressed with a standard hip arthroscopy protocol. Hip flexion was limited to not exceed 90 degrees for the first three weeks post-op, with progression back to running beginning at three months. Final discharge was dependent upon the ability to run two miles at military specified pace and do a single leg broad jump within six inches of the contralateral leg without an increase in pain. Eleven participants met inclusion criteria over the study period. Crutch use was discontinued at an average of five days following surgery based on established weight bearing criteria. Only one participant required continued crutch use at 15 days. Participants' functional outcome was improved postoperatively, as demonstrated by significant increases in HOS and HHS. At the six month follow up, eight of 11 participants were able to take and complete a full Army Physical Fitness Test. Following completion of the early weight bearing rehabilitation protocol, 81% of participants were able to progress to full weight bearing by four days post-operative, with normalized pain-free gait patterns. Active duty personnel utilizing an early weight bearing protocol following hip arthroscopy demonstrated significant functional improvement at six months. Level 4, Case-series.

  11. Serum Metal Ion Levels Following Total Hip Arthroplasty With Modular Dual Mobility Components.

    PubMed

    Matsen Ko, Laura J; Pollag, Kimberley E; Yoo, Joanne Y; Sharkey, Peter F

    2016-01-01

    Dual mobility acetabular components can reduce the incidence of total hip arthroplasty (THA) instability. Modular dual mobility (MDM) components facilitate acetabular component implantation. However, corrosion can occur at modular junctions. Serum cobalt and chromium levels and Oxford scores were obtained at minimum two year follow-up for 100 consecutive patients who had THA with MDM components. Average Oxford score was 43 (range 13-48). Average serum cobalt and chromium values were 0.7 mcg/L (range, 0.0 to 7.0) and 0.6 mcg/L (range, 0.1 to 2.7), respectively. MARS MRI was performed for four patients with pain and elevated serum cobalt levels. Two of these studies were consistent with adverse local tissue reaction. We recommend use of MDM implants in only patients at high risk for dislocation following THA. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Tendoscopic Double-Row Suture Bridge Peroneal Retinaculum Repair for Recurrent Dislocation of Peroneal Tendons in the Ankle.

    PubMed

    Nishimura, Akinobu; Nakazora, Shigeto; Ito, Naoya; Fukuda, Aki; Kato, Ko; Sudo, Akihiro

    2016-06-01

    Traumatic dislocation of peroneal tendons in the ankle is an uncommon lesion that mainly affects young adults. Unfortunately, most cases lead to recurrent dislocation of the peroneal tendons of the ankle (RPTD). Therefore, most cases need operative treatment. One of the most common operative procedures is superior peroneal retinaculum (SPR) repair. Recently, surgery for RPTD has been achieved with less invasive arthroscopic procedures. In this article, tendoscopic surgery for RPTD using a double-row suture bridge technique is introduced. This technique consists of debridement of the lateral aspect of the fibula under an intrasheath pseudo-cavity, suture anchor insertion into the fibular ridge, and reattachment of the SPR to the fibula using a knotless anchor screwed into the lateral aspect of the fibula. This technique mimics the double-row suture bridge technique for rotator cuff tear repair. The double-row suture bridge technique requires more surgical steps than the single-row technique, but it provides a wider bone-SPR contact surface and tighter fixation than the single-row technique. This procedure is an attractive option because it is less invasive and has achieved results similar to open procedures.

  13. Acute unilateral hip pain in fibrodysplasia ossificans progressiva (FOP).

    PubMed

    Kaplan, Frederick S; Al Mukaddam, Mona; Pignolo, Robert J

    2018-04-01

    Flare-ups of the hips are among the most feared and disabling complications of fibrodysplasia ossificans progressiva (FOP) and are poorly understood. In order to better understand the nature of hip flare-ups in FOP, we evaluated 25 consecutive individuals with classic FOP (14 males, 11 females; 3-56years old, median age, 17years old) who presented with acute unilateral hip pain. All 25 individuals were suspected of having a flare-up of the hip based on clinical history and a favorable response to a four day course of high-dose oral prednisone. Ten individuals (40%) experienced rebound symptoms of pain and/or stiffness within seven days after discontinuation of prednisone and all ten subsequently developed heterotopic ossification (HO) or decreased mobility of the affected hip. None of the 14 individuals who experienced sustained relief of symptoms following a course of oral prednisone experienced HO or decreased mobility. Incidental radiographic findings at the time of presentation were multifactoral and included osteochondromas of the proximal femur (18/25; 72%), degenerative arthritis (17/25; 68%), developmental hip dysplasia (15/25; 60%), previously existing heterotopic ossification (12/25; 48%), intra-articular synovial osteochondromatosis (8/25; 32%) or traumatic fractures through pre-existing heterotopic bone (1/25; 4%). Developmental joint pathology may confound clinical evaluation of hip pain in FOP. The most useful modality for suspecting an ossification-prone flare-up of the hip was lack of sustained response to a brief course of oral prednisone. Evaluation of soft tissue edema by ultrasound or magnetic resonance imaging showed promise in identifying ossification-prone flare-ups and warrants further analysis in prospective studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Associations of hip osteoarthritis with history of recurrent exposure to manual handling of loads over 20 kg and work participation: a population-based study of men and women.

    PubMed

    Kaila-Kangas, Leena; Arokoski, Jari; Impivaara, Olli; Viikari-Juntura, Eira; Leino-Arjas, Päivi; Luukkonen, Ritva; Heliövaara, Markku

    2011-10-01

    We reviewed work histories of manual handling of loads >20 kg in relation to hip osteoarthritis by age, exposure and work participation. A nationally representative sample of 3110 Finnish men and 3446 women aged 30-97 was recruited. Diagnosis of hip osteoarthritis was based on standardised clinical examination by trained physicians. Previous exposure to physically loading work was evaluated through interviews. Logistic regression was used to estimate associations between work factors and hip osteoarthritis. 1.9% of men and 2.1% of women had hip osteoarthritis. Almost half the men and a quarter of the women had recurrently handled heavy loads at work. Subjects who had manually handled loads >20 kg had a 1.8-fold increased risk of hip osteoarthritis compared to non-exposed references, when age, body mass index, traumatic fractures and smoking were accounted for. Results were similar for men (OR 2.0; 95% CI 1.0 to 4.0) and women (1.8; 1.1 to 2.8). In a sub-analysis of subjects with hip replacement, the OR was 1.7 (1.0 to 2.9). Risk increased first after 12 years' exposure: among men it was 2.2 (0.8 to 5.9) for 13-24 years' exposure, and 2.3 (1.2 to 4.3) for >24 years' exposure. Among women it was 3.8 (1.7 to 8.1) for 13-24 years' exposure. Work participation among men aged <60 years with hip osteoarthritis was 20% lower compared with subjects without osteoarthritis. A work history of manual handling of loads >20 kg showed a strong association with hip osteoarthritis in all age groups except the youngest.

  15. Post Traumatic Avascular Necrosis of the Proximal Carpal Row--A Case Report.

    PubMed

    Manohara, Ruben; Sebastin, Sandeep Jacob; Puhaindran, Mark Edward

    2015-10-01

    We report a case of avascular necrosis of the scaphoid, lunate and triquetrum in a young 21-year-old patient, after a purely ligamentous peri-lunate dislocation of the wrist. He presented with a Mayfield III peri-lunate dislocation after a road traffic accident and underwent an open reduction and internal fixation. Post-operatively, the scapho-lunate gap widened after removal of the temporary K-wires, and he gradually developed avascular necrosis of the scaphoid, lunate and triquetrum, and osteoarthritis of his wrist. We present this unusual case of simultaneous avascular necrosis of multiple carpal bones and discuss the possible risk factors and subsequent management plans for this complex injury. Our patient has no identifiable contributing factors to developing avascular necrosis. We suspect that the violence of the injury and surgery may have compromised the circulation, and advise caution when treating and counseling these patients pre-operatively.

  16. Management of failed instability surgery: how to get it right the next time.

    PubMed

    Boone, Julienne L; Arciero, Robert A

    2010-07-01

    Traumatic anterior shoulder dislocations are the most frequent type of joint dislocation and affect approximately 1.7% of the general population. The literature supports the consideration of primary stabilization in high-risk patients because of reported recurrences as high as 80% to 90% with nonoperative treatment regimens. Successful stabilization of anterior glenohumeral instability relies on not only good surgical techniques but also careful patient selection. Failure rates after open and arthroscopic stabilization have been reported to range from 2% to 8% and 4% to 13%, respectively. Recurrent shoulder instability leads to increased morbidity to the patient, increased pain, decreased activity level, prolonged time away from work and sports, and a general decrease in quality of life. This article reviews the potential pitfalls in anterior shoulder stabilization and discusses appropriate methods of addressing them in revision surgery. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Early treatment with the von Rosen splint for neonatal instability of the hip is safe regarding avascular necrosis of the femoral head

    PubMed Central

    Wenger, Daniel; Samuelsson, Hanna; Düppe, Henrik; Tiderius, Carl Johan

    2016-01-01

    Background and purpose — Avascular necrosis of the femoral head (AVN) is a complication in treatment of developmental dysplasia of the hip (DDH). We evaluated the risk of AVN after early treatment in the von Rosen splint and measured the diameter of the ossific nucleus at 1 year of age. Children and methods — All children born in Malmö, Sweden, undergo clinical screening for neonatal instability of the hip (NIH). We reviewed 1-year radiographs of all children treated early for NIH in our department from 2003 through 2010. The diameter of the ossific nucleus was measured, and signs of AVN were classified according to Kalamchi-MacEwen. Subsequent radiographs, taken for any reason, were reviewed and a local registry of diagnoses was used to identify subsequent AVN. Results — 229 of 586 children referred because of suspected NIH received early treatment (age ≤ 1 week) for NIH during the study period. 2 of the 229 treated children (0.9%, 95% CI: 0.1–3.1) had grade-1 AVN. Both had spontaneous resolution and were asymptomatic during the observation time (6 and 8 years). 466 children met the inclusion criteria for measurement of the ossific nucleus. Neonatally dislocated hips had significantly smaller ossific nuclei than neonatally stable hips: mean 9.4 mm (95% CI: 9.1–9.8) vs. 11.1 mm (95% CI: 10.9–11.3) at 1 year (p < 0.001). Interpretation — Early treatment with the von Rosen splint for NIH is safe regarding AVN. The ossification of the femoral head is slower in children with NIH than in untreated children with neonatally stable hips. PMID:26730503

  18. Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.

    PubMed

    Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D

    2015-04-01

    The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.

  19. Effect of Body Mass Index on Complications and Reoperations After Total Hip Arthroplasty.

    PubMed

    Wagner, Eric R; Kamath, Atul F; Fruth, Kristin M; Harmsen, William S; Berry, Daniel J

    2016-02-03

    High body mass index (BMI) is associated with increased rates of complications after total hip arthroplasty. Studies to date have evaluated risk mainly as a dichotomous variable according to BMI thresholds. The purpose of this paper was to characterize the risk of complications and implant survival according to BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 21,361 consecutive hips (17,774 patients) treated with primary total hip arthroplasty between 1985 and 2012 at a single institution. The average BMI at the time of surgery was 28.7 kg/m(2) (range, 15 to 69 kg/m(2)). Estimates of revision surgery and common complications associated with BMI were analyzed using the Kaplan-Meier method of assessing survivorship, with associations of outcomes assessed using a Cox model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p = 0.002) increased with increasing BMI. Increasing BMI was associated with increased rates of early hip dislocation (p = 0.02), wound infection, and, most strikingly, deep periprosthetic infection (a hazard ratio of 1.09 per unit of BMI >25 kg/m(2); p < 0.001). However, we found no association between increasing BMI and any revision for mechanical failure of the implant or between increasing BMI and revision for aseptic implant loosening. There was an inverse correlation between increasing BMI and risk of revision for bearing wear. The rates of reoperation, implant revision or removal, and common complications after total hip arthroplasty were strongly associated with BMI. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  20. Tuberculosis of the hip in children: A retrospective analysis of 27 patients.

    PubMed

    Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas

    2014-09-01

    We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial "triradiate" and normal types and worst with posttreatment atrophic and "ankylosed" types. The Shanmugasundaram radiological types accurately predict prognosis only in normal types and "triradiate" pattern. The functional outcome is independent of radiological morphology of the hip in smaller children.

  1. Tuberculosis of the hip in children: A retrospective analysis of 27 patients

    PubMed Central

    Agarwal, Anil; Suri, Tarun; Verma, Indereshwar; Kumar, Shashi Kant; Gupta, Neeraj; Shaharyar, Abbas

    2014-01-01

    Background: We retrospectively evaluated the pretreatment radiological presentation and the clinicoradiological outcome at the completion of 1 year chemotherapy in osteoarticular tuberculosis of hip in children to prognosticate correlation between them. Materials and Methods: We retrospectively analyzed the clinical and plain radiographic findings in 27 patients with an age of 12 years or younger in whom hip tuberculosis was diagnosed and treated between 2006 and 2010. The diagnosis was based on histopathology in 14 and clinicoradiological basis in 13 patients. The pre and post treatment plain radiographs were evaluated according to Shanmugasundaram radiological classification and our observations regarding unclassified cases which were not fit in this classification were suggested. The functional outcome at the completion of chemotherapy was assessed using modified Moon's criteria. Results: The male female ratio was 11:16. The left hip was involved more frequently than the right (17:10). The average age was 7.37 years (range, 2-12 years). In the pretreatment radiographs, 9 hips were normal, 6 traveling, 4 dislocating, 1 protrusio acetabuli, 3 atrophic and 4 unclassified types (3 triradiate; 1 pseudarthrosis coxae). There were no Perthes and mortar pestle at the initial presentation. Posttreatment, the types changed to 9 normal, 3 Perthes, 1 protrusio acetabuli, 1 atrophic, 4 mortar pestle and 9 unclassified types (3 triradiate, 3 pseudarthrosis coxae and 3 ankylosed). There were 37% excellent, 18.5% good, 26% fair and 18.5% poor results. The prognosis was best with initial “triradiate” and normal types and worst with posttreatment atrophic and “ankylosed” types. Conclusions: The Shanmugasundaram radiological types accurately predict prognosis only in normal types and “triradiate” pattern. The functional outcome is independent of radiological morphology of the hip in smaller children. PMID:25298552

  2. Spectroscopic Biomarkers for Monitoring Wound Healing and Infection in Combat Wounds

    DTIC Science & Technology

    2012-10-29

    injuries, burns, acute vascular disruption, blastwave-associated pressure injuries, air, thrombotic, and fat embolism , and compartment syndrome. In...damage and compromised local circulation often associated with overt vascular injury. These injuries include traumatic amputations, open fractures , crush...HO formation has been observed following orthopedic surgery (total hip arthroplasty as well as acetabular and elbow fracture surgery), burn injury

  3. Total Hip Arthroplasty in Patients With Avascular Necrosis After Hematopoietic Stem Cell Transplantation.

    PubMed

    Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R

    2018-03-01

    The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.

  4. Is total hip arthroplasty safely performed in lung transplant patients? Current experience from a retrospective study of the Zurich lung transplant cohort.

    PubMed

    Schmitt, Jürgen W; Benden, Christian; Dora, Claudio; Werner, Clément M L

    2016-01-01

    In recent years, the number of lung transplants has increased rapidly, with higher quality of life and improved survival rates in transplant recipients, including patients with advanced age. This, in turn, means that more transplant recipients will seek musculoskeletal care to treat degenerative joint disease and also trauma incidents. Safety concerns regarding elective and posttraumatic hip arthroplasty in transplant patients include an increased risk of infection, wound healing problems, periprosthetic fractures and loosening of the implants. Clinical outcomes and safety aspects were retrospectively reviewed for five primary total hip arthroplasties (THA) in lung transplant recipients with minimal follow-up of two years at average of 2.6 (2-11) years. Patients were recruited from the Zurich Lung Transplant Center comprising of a cohort of 253 patients between January 1st, 2004 and December 31st, 2013. All five patients subjectively reported excellent outcomes after THA with a final average Harris Hip Score of 97 (86-100). One 71-year-old patient died 26 months after THA unrelated to arthroplasty. One superficial wound healing disturbance was documented. No periprosthetic fractures, no dislocations, no periprosthetic infections, no further revision surgery, no implant loosening was observed. In conclusion, THA can be safely and successfully performed even in lung transplant patients under long-term immunosuppressive therapy and polymedication, provided a multidisciplinary approach can be granted.

  5. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    PubMed Central

    Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan

    2014-01-01

    The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703

  6. Similar range of motion and function after resurfacing large–head or standard total hip arthroplasty

    PubMed Central

    2013-01-01

    Background and purpose Large–size hip articulations may improve range of motion (ROM) and function compared to a 28–mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) could impair rehabilitation. We investigated the effect of head size and surgical procedure on postoperative rehabilitation in a randomized clinical trial (RCT). Methods We followed randomized groups of RHAs, large–head THAs and standard THAs at 2 months, 6 months, 1 and 2 years postoperatively, recording clinical rehabilitation parameters. Results Large articulations increased the mean total range of motion by 13° during the first 6 postoperative months. The increase was not statistically significant and was transient. The 2–year total ROM (SD) for RHA, standard THA, and large–head THA was 221° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. Interpretation Head size had no influence on range of motion. The lack of restriction allowed for large articulations did not improve the clinical and patient–perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762. PMID:23530872

  7. [Imaging of traumatic injuries of the knee].

    PubMed

    Blin, D; Cyteval, C; Kamba, C; Blondel, M; Lopez, F M

    2007-05-01

    Traumatic injuries to the knee are frequent (road or sports related accidents, falls in elderly people). The Ottawa knee rules are applied and dictate the need for additional evaluation. Some fractures are adequately assessed on plain radiographs alone whereas other fractures (tibial plateau fracture) require additional evaluation with CT. Some fractures may be occult: the significance of lipohemarthrosis (indirect sign of intra-articular fracture on the lateral radiograph with horizontal beam) must be known. Benign appearing avulsion fractures suggest the presence of underlying capsuloligamentous injuries requiring further evaluation with MRI. The imaging work-up of sprains is usually negative. MRI may show areas of bone contusion that further the understanding of the mechanism of injury, predict and confirm the presence of capsuloligamentous injuries. Angiography is performed to detect popliteal artery injuries after knee dislocation which is associated with a risk of ischemia.

  8. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    PubMed

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly patients, hip joint function in patients aged more than 80 years old is worse, while there was no obvious market effect in fracture classification, whether to use tension band and type of distal fixation prosthesis, moreover, proximal femoral osteolysis should be focused on.

  9. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    PubMed

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.

  10. Does Participation in Sports Affect Osteoarthritic Progression After Periacetabular Osteotomy?

    PubMed

    Hara, Daisuke; Hamai, Satoshi; Fukushi, Jun-Ichi; Kawaguchi, Ken-Ichi; Motomura, Goro; Ikemura, Satoshi; Komiyama, Keisuke; Nakashima, Yasuharu

    2017-09-01

    Periacetabular osteotomy (PAO) is an effective treatment for symptomatic acetabular dysplasia. However, whether postoperative participation in sports leads to progression of the Kellgren-Lawrence (KL) grade of osteoarthritis (OA) in these patients is unclear. To investigate (1) participation in sports before and after PAO and (2) whether postoperative participation in sports leads to progression of the KL grade. Case-control study; Level of evidence, 3. The authors retrospectively reviewed data on 161 patients (183 hips) who underwent PAO for symptomatic acetabular dysplasia with preoperative KL grade 1 or 2 between 1998 and 2011. The mean age at the time of surgery was 42.0 ± 10.9 years (range, 12-64 years), and the mean follow-up duration was 100 months (range, 13-180 months). Data included participation in sports, the University of California, Los Angeles (UCLA) activity scale score, age at the time of surgery, body mass index, follow-up duration, history of treatment for developmental hip dislocations, Merle d'Aubigné-Postel score, Oxford Hip Score, center-edge angle, and KL grade. Univariate and multivariate analyses were applied to determine which factors were associated with progression to KL grade 3 or 4 after PAO. The number of patients who participated in sports significantly increased from 50 (31.1%) preoperatively to 89 (55.3%) postoperatively. The mean UCLA score significantly increased from 4.7 ± 2.1 preoperatively to 5.5 ± 2.0 postoperatively. The KL grade progressed to grade 3 or 4 in 16 hips, including 4 hips that underwent conversion to total hip arthroplasty. No significant differences were found in postoperative participation in sports (89 hips [53.3%] vs 11 hips [68.8%], respectively; P = .24) and the UCLA score (5.6 ± 2.0 vs 5.1 ± 2.0, respectively; P = .30) between hips with KL grade 1 or 2 and KL grade 3 or 4. A multivariate analysis revealed that no factors, including postoperative participation in sports, were significantly associated with progression to KL grade 3 or 4. Postoperative participation in sports after PAO did not significantly and negatively influence progression of the KL grade at midterm follow-up.

  11. [Larsen syndrome: two reports of cases with spinal cord compromise].

    PubMed

    Martín Fernández-Mayoralas, D; Fernández-Jaén, A; Muñoz-Jareño, N; Calleja-Pérez, B; San Antonio-Arce, V; Martínez-Boniche, H

    Larsen syndrome is characterised by untreatable congenital dislocation of multiple body joints, along with marked foot deformities. These patients have a flattened face with a short nose, a broad depressed nasal bridge and a prominent forehead. In this clinical note our aim is to report two cases that coursed with spinal cord compromise. Case 1: an 18-month-old female with congenital dislocation of knees and hips. The patient had a flat face, sunken root of nose, and carp mouth. Magnetic resonance imaging of the spine showed severe cervical kyphosis secondary to malformation and hypoplasia of the cervical vertebral bodies and important compression of the spinal cord. Clinically, there were also signs of upper motor neuron syndrome, which was especially prominent in the lower limbs. Case 2: a 14-year-old male with a characteristic face and dislocation of the head of the radius. The patient presented amyotrophy of the muscles in the right hand and clinical signs of lower motor neuron syndrome due to neuronal damage secondary to spinal malformations. Larsen syndrome is an infrequent osteochondrodysplasia. Alteration of the spine is common and may give rise to spinal cord compression with varying clinical repercussions which require surgical treatment in the early years of the patient's life.

  12. Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty.

    PubMed

    Berger, Richard A; Jacobs, Joshua J; Meneghini, R Michael; Della Valle, Craig; Paprosky, Wayne; Rosenberg, Aaron G

    2004-12-01

    To assess the potential recovery rate of a minimally invasive total hip replacement technique with minimal soft tissue disruption, an accelerated rehabilitation protocol was implemented with weightbearing as tolerated on the day of surgery. One hundred consecutive patients were enrolled in this prospective study. Ninety-seven patients (97%) met all the inpatient physical therapy goals required for discharge to home on the day of surgery; 100% of patients achieved these goals within 23 hours of surgery. Outpatient therapy was initiated in 9% of patients immediately, 62% of patients by 1 week, and all patients by 2 weeks. The mean time to discontinued use of crutches, discontinued use of narcotic pain medications, and resumed driving was 6 days postoperatively. The mean time to return to work was 8 days, discontinued use of any assistive device was 9 days, and resumption of all activities of daily living was 10 days. The mean time to walk (1/2) mile was 16 days. Furthermore, there were no readmissions, no dislocations, and no reoperations. Therefore, a rapid rehabilitation protocol is safe and fulfills the potential benefits of a rapid recovery with minimally invasive total hip arthroplasty.

  13. What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

    PubMed

    Abdel, Matthew P; von Roth, Philipp; Jennings, Matthew T; Hanssen, Arlen D; Pagnano, Mark W

    2016-02-01

    Numerous factors influence total hip arthroplasty (THA) stability including surgical approach and soft tissue tension, patient compliance, and component position. One long-held tenet regarding component position is that cup inclination and anteversion of 40° ± 10° and 15° ± 10°, respectively, represent a "safe zone" as defined by Lewinnek that minimizes dislocation after primary THA; however, it is clear that components positioned in this zone can and do dislocate. We sought to determine if these classic radiographic targets for cup inclination and anteversion accurately predicted a safe zone limiting dislocation in a contemporary THA practice. From a cohort of 9784 primary THAs performed between 2003 and 2012 at one institution, we retrospectively identified 206 THAs (2%) that subsequently dislocated. Radiographic parameters including inclination, anteversion, center of rotation, and limb length discrepancy were analyzed. Mean followup was 27 months (range, 0-133 months). The majority (58% [120 of 206]) of dislocated THAs had a socket within the Lewinnek safe zone. Mean cup inclination was 44° ± 8° with 84% within the safe zone for inclination. Mean anteversion was 15° ± 9° with 69% within the safe zone for anteversion. Sixty-five percent of dislocated THAs that were performed through a posterior approach had an acetabular component within the combined acetabular safe zones, whereas this was true for only 33% performed through an anterolateral approach. An acetabular component performed through a posterior approach was three times as likely to be within the combined acetabular safe zones (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.1-1.6) than after an anterolateral approach (OR, 0.4; 95% CI, 0.2-0.7; p < 0.0001). In contrast, acetabular components performed through a posterior approach (OR, 1.6; 95% CI, 1.2-1.9) had an increased risk of dislocation compared with those performed through an anterolateral approach (OR, 0.8; 95% CI, 0.7-0.9; p < 0.0001). The historical target values for cup inclination and anteversion may be useful but should not be considered a safe zone given that the majority of these contemporary THAs that dislocated were within those target values. Stability is likely multifactorial; the ideal cup position for some patients may lie outside the Lewinnek safe zone and more advanced analysis is required to identify the right target in that subgroup. Level III, therapeutic study.

  14. Revision of cemented hip arthroplasty using a hydroxyapatite-ceramic-coated femoral component.

    PubMed

    Raman, R; Kamath, R P; Parikh, A; Angus, P D

    2005-08-01

    We report the clinical and radiological outcome of 86 revisions of cemented hip arthroplasties using JRI-Furlong hydroxyapatite-ceramic-coated acetabular and femoral components. The acetabular component was revised in 62 hips and the femoral component in all hips. The mean follow-up was 12.6 years and no patient was lost to follow-up. The mean age of the patients was 71.2 years. The mean Harris hip and Oxford scores were 82 (59 to 96) and 23.4 (14 to 40), respectively. The mean Charnley modification of the Merle d'Aubigné and Postel score was 5 (3 to 6) for pain, 4.9 (3 to 6) for movement and 4.4 (3 to 6) for mobility. Migration of the acetabular component was seen in two hips and the mean acetabular inclination was 42.6 degrees. The mean linear polyethylene wear was 0.05 mm/year. The mean subsidence of the femoral component was 1.9 mm and stress shielding was seen in 23 (28%) with bony ingrowth in 76 (94%). Heterotopic ossification was seen in 12 hips (15%). There were three re-revisions, two for deep sepsis and one for recurrent dislocation and there were no re-revisions for aseptic loosening. The mean EuroQol EQ-5D description scores and health thermometer scores were 0.69 (0.51 to 0.89) and 79 (54 to 95), respectively. With an end-point of definite or probable loosening, the probability of survival at 12 years was 93.9% and 95.6% for the acetabular and femoral components, respectively. Overall survival at 12 years, with removal or further revision of either component for any reason as the end-point, was 92.3%. Our study supports the continued use of this arthroplasty and documents the durability of hydroxyapatite-ceramic-coated components.

  15. [The role of exogenous factors in the etiology of congenital hip dislocation: a socio-epidemiologic study].

    PubMed

    Drimal, J

    1989-10-01

    The authors present in their work the results of the analysis of the relation between congenital dislocation of vertebral joints and social factors which they have found out in 120 children singled out of 9516 live-born children in the Martin district (Slovakia) in the period 1979-1983. The investigation of social factors has been based on the analysis of socioeconomic and social conditions of the Martin district which has no regional particularities. According to their results the share of exogenous factors in the origin and development of this disease is manifested more frequently in the first-borns (having the highest representation in the examined group). On the top of the list of social indices, which they have examined in primiparae and multiparae respectively, there are unsuitable housing conditions (living in discord with mother-in-law in the same house-hold), high percentage of impregnation before marriage which can be considered a strain and longterm conflicting situation and can have together with other factors a sociopathogenetic effect.

  16. [Ceramic-ceramic articulation in uncemented total hip arthroplasty].

    PubMed

    Synder, Marek; Drobniewski, Marek; Kozłowski, Piotr; Grzegorzewski, Andrzej

    2005-01-01

    The main problem in total hip arthroplasty (THA) surgery is aseptic loosening of prosthesis components. In most cases the phagocytes reaction against the wear particle during the hip movement is responsible for aseptic prosthesis loosening. To prevent this reaction different hip articulation are invented to reduce this reaction. One of these solutions is ceramic-ceramic hip prosthesis articulation. The aim of this study was to evaluate the long-term results in patients who were treated because of coxarthrosis by means of ceramic-ceramic hip prosthesis. We analyzed 258 primary THA (222 patients, 116 women and 106 men) who were treated because of advanced coxarthrosis by Mittelmeier type hip endoprosthesis (ceramic-ceramic articulation). The mean age of patients at the surgery was 45.6 years and a mean follow-up 10.2 years. In most of our cases the idiopathic, traumatic and dysplastic coxarthrosis was noted. For clinical evaluation the classification system proposed by Merle d'Aubigne and Postel with Charnley modification was used. For radiological evaluation of the steam implantation the classification system proposed by De Lee and Charnley was used and for the cup implantation the system by Gruen and Moreland. In 87 patients (33.7%) the final results was graded as very good, in 96 (37.2%) as good, in 47 (18.2%) as satisfactory and in 28 patients (10.9%) the final results was poor. In analyzed group in 13 patients (5.0%) the revision surgery was necessary. The long-term results of THA with the use of Mittelmeier type of hip prosthesis presented a very low percentage of aseptic loosening. This type of prosthesis gives very high patients satisfaction.

  17. Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.

    PubMed

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2010-09-01

    The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r=-0.25), or between the neck-shaft angle and the femoral anteversion (r=0.23). The neck-shaft angle, the femoral anteversion, and the CT migration percentage were significantly larger, and the femoral offset was significantly smaller, in patients with the Gross Motor Functional Classification System (GMFCS) level IV/V (nonwalking children) and SQ type, than in patients with GMFCS level II/III (mostly walking children) and SD type. The 3-dimensional femoral geometry in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. Our data indicate that 3-dimensional evaluation is accurate and useful for analysis of the femur and acetabulum in CP, and that the extent of coxa valga and femoral anteversion is more severe in the patients with GMFCS level IV/V and SQ type. Level IV.

  18. Primary total hip arthroplasty versus hemiarthroplasty for displaced intracapsular hip fractures in older patients: systematic review.

    PubMed

    Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael

    2010-06-11

    To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.

  19. Sonography on injury of the medial patellofemoral ligament after acute traumatic lateral patellar dislocation: Injury patterns and correlation analysis with injury of articular cartilage of the inferomedial patella.

    PubMed

    Zhang, Guang-Ying; Zheng, Lei; Shi, Hao; Qu, Su-Hui; Ding, Hong-Yu

    2013-12-01

    The purpose of this study was to investigate the accuracy of high-frequency ultrasonography in the diagnosis of injuries of medial patellofemoral ligaments (MPFLs), analyse the characteristics of MPFL injury and correlations between injury of the MPFL and articular cartilage of the inferomedial patella in patients with acute traumatic lateral patellar dislocation. High-frequency sonographic images of 49 patients with acute traumatic lateral patellar dislocations treated surgically were reviewed. The χ(2) tests were performed for statistical analysis. Twenty-eight cases of complete MPFL tear and 21 cases of partial MPFL tear were identified in operation, with 27 cases of MPFL tear located at their femoral attachment, 21 cases of tear at the patellar attachment and one case of midsubstance tear. The diagnostic accuracy of sonography regarding partial MPFL tear and complete MPFL tear was 89.8% and 89.8%. Among the patients with MPFL tear at the patellar attachment, eight and six cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, in contrast to nine and six cases in patients with MPFL tear at the femoral attachment, respectively. There was no significant difference between the two locations described above regarding the prevalence rates of chondral or osteochondral lesions of the inferomedial patella (P=0.732, P=0.614). Among the patients with complete MPFL tear, 12 and 10 cases were concomitant with chondral and osteochondral lesions in the inferomedial patella, respectively, while six and two cases were concomitant with partial MPFL tear. There was no significant difference between the two types of injuries discussed above on the prevalence rates of chondral lesions of the inferomedial patella (P=0.305), but the prevalence rate of osteochondral lesions between the two types of injuries discussed above was statistically different (P=0.035). The MPFL is most easily injured at the femoral attachment, secondly at the patellar attachment. High-frequency ultrasonography is an accurate method in the diagnosis of an MPFL tear. There are neither significant differences on the prevalence rates of chondral or osteochondral lesions of the inferomedial patella between locations of MPFL injuries, nor significant difference on the prevalence rates of chondral lesions between MPFL injury types; but the complete MPFL tear is more often concomitant with inferomedial patellar osteochondral lesions than the partial MPFL tear. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Neuromuscular prehabilitation to prevent osteoarthritis after a traumatic joint injury.

    PubMed

    Tenforde, Adam S; Shull, Pete B; Fredericson, Michael

    2012-05-01

    Post-traumatic osteoarthritis (PTOA) is a process resulting from direct forces applied to a joint that cause injury and degenerative changes. An estimated 12% of all symptomatic osteoarthritis (OA) of the hip, knee, and ankle can be attributed to a post-traumatic cause. Neuromuscular prehabilitation is the process of improving neuromuscular function to prevent development of PTOA after an initial traumatic joint injury. Prehabilitation strategies include restoration of normative movement patterns that have been altered as the result of traumatic injury, along with neuromuscular exercises and gait retraining to prevent the development of OA after an injury occurs. A review of the current literature shows that no studies have been performed to evaluate methods of neuromuscular prehabilitation to prevent PTOA after a joint injury. Instead, current research has focused on management strategies after knee injuries, the value of exercise in the management of OA, and neuromuscular exercises after total knee arthroplasty. Recent work in gait retraining that alters knee joint loading holds promise for preventing the development of PTOA after joint trauma. Future research should evaluate methods of neuromuscular prehabilitation strategies in relationship to the outcome of PTOA after joint injury. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  1. The relationship between alpha angle and resistive index of the femoral epiphysis in the normal and abnormal infant hip.

    PubMed

    Amodio, John; Rivera, Rafael; Pinkney, Lynne; Strubel, Naomi; Fefferman, Nancy

    2006-08-01

    The arterial vascularity of the hip has been investigated in normal infants using duplex Doppler sonography. This study addressed the differences in hip vascularity in infants with respect to gender and acetabular morphology. To determine whether there is a relationship between the resistive index of the vessels of the femoral chondroepiphysis and the alpha angle in normal infant hips and in those with developmental dysplasia of the hip. We studied 76 hips (38 patients) with gray-scale and power Doppler US. The patients were referred because of a possible abnormal clinical hip examination or had risk factors for developmental dysplasia of the hip. The infants ranged in age from 1 day to 6 weeks. There were 13 boys and 25 girls. Gray-scale images were initially performed in the coronal and transverse planes to evaluate acetabular morphology, alpha angle and position of the femoral chondroepiphysis relative to the acetabulum. The hips were then examined with power Doppler US, in both sagittal and transverse planes, to identify arterial vessels within the femoral epiphysis. Resistive indices were then recorded from the spectral analysis in each vessel identified. Each examination was performed by one of five pediatric radiologists. Mixed model regression was used to assess the relationship between resistive index and alpha angle, age and gender. Of the 76 hips, 34 had an alpha angle of 60 degrees or greater and were classified as normal, 26 had an alpha angle between 50 degrees and 59 degrees and were classified as immature, and 13 had an alpha angle of less than 50 degrees and were either subluxed or dislocated at the time of examination. At least two vessels were documented in each femoral epiphysis except in three hips, in which no vessels could be documented because of technical factors. There was a statistically significant linear relationship between the alpha angle and resistive index, such that the resistive index tended to rise with increasing alpha angle (P=0.0022). In addition, female infants had a significantly higher average resistive index than the average resistive index in male infants with the same alpha angle (P=0.0005). There is a direct linear relationship between alpha angle and resistive index in the infant hip. Female infants have a higher average resistive index than male infants. We believe that these results might serve as a model for predicting an infant hip at risk of ischemia. In addition, the fact that lower resistive indices of the femoral epiphysis are associated with acetabular dysplasia might help explain the documented low incidence of avascular necrosis in untreated hip dysplasia.

  2. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    PubMed Central

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  3. Long-term Outcome of Unconstrained Primary Total Hip Arthroplasty in Ipsilateral Residual Poliomyelitis.

    PubMed

    Buttaro, Martín A; Slullitel, Pablo A; García Mansilla, Agustín M; Carlucci, Sofía; Comba, Fernando M; Zanotti, Gerardo; Piccaluga, Francisco

    2017-03-01

    Incapacitating articular sequelae in the hip joint have been described for patients with late effects of poliomyelitis. In these patients, total hip arthroplasty (THA) has been associated with a substantial rate of dislocation. This study was conducted to evaluate the long-term clinical and radiologic outcomes of unconstrained THA in this specific group of patients. The study included 6 patients with ipsilateral polio who underwent primary THA between 1985 and 2006. Patients with polio who underwent THA on the nonparalytic limb were excluded. Mean follow-up was 119.5 months (minimum, 84 months). Clinical outcomes were evaluated with the modified Harris Hip Score (mHHS) and the visual analog scale (VAS) pain score. Radiographs were examined to identify the cause of complications and determine the need for revision surgery. All patients showed significantly better functional results when preoperative and postoperative mHHS (67.58 vs 87.33, respectively; P=.002) and VAS pain score (7.66 vs 2, respectively; P=.0003) were compared. Although 2 cases of instability were diagnosed, only 1 patient needed acetabular revision as a result of component malpositioning. None of the patients had component loosening, osteolysis, or infection. Unconstrained THA in the affected limb of patients with poliomyelitis showed favorable long-term clinical results, with improved function and pain relief. Nevertheless, instability may be a more frequent complication in this group of patients compared with the general population. [Orthopedics. 2017; 40(2):e255-e261.]. Copyright 2016, SLACK Incorporated.

  4. Early Outcomes of Primary Total Hip Arthroplasty After Prior Lumbar Spinal Fusion.

    PubMed

    Barry, Jeffrey J; Sing, David C; Vail, Thomas P; Hansen, Erik N

    2017-02-01

    The coexistence of degenerative hip disease and spinal pathology is not uncommon with the number of surgical treatments performed for each condition increasing annually. The limited research available suggests spinal pathology portends less pain relief and worse outcomes after total hip arthroplasty (THA). We hypothesize that primary THA patients with preexisting lumbar spinal fusions (LSF) experience worse early postoperative outcomes. This study is a retrospective matched cohort study. Primary THA patients at 1 institution who had undergone prior LSF (spine arthrodesis-hip arthroplasty [SAHA]) were identified and matched to controls of primary THA without LSF. Early outcomes (<90 days) were compared. From 2012 to 2014, 35 SAHA patients were compared to 70 matched controls. Patients were similar in age, sex, American Society of Anesthesiologist score, body mass index, and Charlson Comorbidity Index. SAHA patients had higher rates of complications (31.4% vs 8.6%, P = .008), reoperation (14.3% vs 2.9%, P = .040), and general anesthesia (54.3% vs 5.7%, P = .0001). Bivariate analysis demonstrated SAHA to predict reoperation (odds ratio, 5.67; P = .045) and complications (odds ratio, 4.89; P = .005). With the numbers available, dislocations (0% vs 2.8%), infections (0% vs 8.6%), readmissions, postoperative walking distance, and disposition only trended to favor controls (P > .05). Comparing controls to SAHA patients with <3 or ≥3 levels fused, longer fusions had increased cumulative postoperative narcotic consumption (mean morphine equivalents, 44.3 vs 46.9 vs 169.4; P = .001). Patients with preexisting LSF experience worse early outcomes after primary THA including higher rates of complications and reoperation. Lower rates of neuraxial anesthesia and increased narcotic usage represent potential contributors. The complex interplay between the lumbar spine and hip warrants attention and further investigation. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Developmental dysplasia of the hip: A computational biomechanical model of the path of least energy for closed reduction.

    PubMed

    Zwawi, Mohammed A; Moslehy, Faissal A; Rose, Christopher; Huayamave, Victor; Kassab, Alain J; Divo, Eduardo; Jones, Brendan J; Price, Charles T

    2017-08-01

    This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society.

  6. More complications with uncemented than cemented femoral stems in total hip replacement for displaced femoral neck fractures in the elderly

    PubMed Central

    Chammout, Ghazi; Muren, Olle; Laurencikas, Evaldas; Bodén, Henrik; Kelly-Pettersson, Paula; Sjöö, Helene; Stark, André; Sköldenberg, Olof

    2017-01-01

    Background and purpose Total hip replacement (THR) is the preferred method for the active and lucid elderly patient with a displaced femoral neck fracture (FNF). Controversy still exists regarding the use of cemented or uncemented stems in these patients. We compared the effectiveness and safety between a modern cemented, and a modern uncemented hydroxyapatite-coated femoral stem in patients 65–79 years of age who were treated with THR for displaced FNF. Patients and methods In a single-center, single-blinded randomized controlled trial, we included 69 patients, mean age 75 (65–79) and with a displaced FNF (Garden III–IV). 35 patients were randomized to a cemented THR and 34 to a reverse-hybrid THR with an uncemented stem. Primary endpoints were: prevalence of all hip-related complications and health-related quality of life, evaluated with EuroQol-5D (EQ-5D) index up to 2 years after surgery. Secondary outcomes included: overall mortality, general medical complications, and hip function. The patients were followed up at 3, 12, and 24 months. Results According to the calculation of sample size, 140 patients would be required for the primary endpoints, but the study was stopped when only half of the sample size was included (n = 69). An interim analysis at that time showed that the total number of early hip-related complications was substantially higher in the uncemented group, 9 (among them, 3 dislocations and 4 periprosthetic fractures) as compared to 1 in the cemented group. The mortality and functional outcome scores were similar in the 2 groups. Interpretation We do not recommend uncemented femoral stems for the treatment of elderly patients with displaced FNFs. PMID:27967333

  7. Assessment of Accuracy and Reliability in Acetabular Cup Placement Using an iPhone/iPad System.

    PubMed

    Kurosaka, Kenji; Fukunishi, Shigeo; Fukui, Tomokazu; Nishio, Shoji; Fujihara, Yuki; Okahisa, Shohei; Takeda, Yu; Daimon, Takashi; Yoshiya, Shinichi

    2016-07-01

    Implant positioning is one of the critical factors that influences postoperative outcome of total hip arthroplasty (THA). Malpositioning of the implant may lead to an increased risk of postoperative complications such as prosthetic impingement, dislocation, restricted range of motion, polyethylene wear, and loosening. In 2012, the intraoperative use of smartphone technology in THA for improved accuracy of acetabular cup placement was reported. The purpose of this study was to examine the accuracy of an iPhone/iPad-guided technique in positioning the acetabular cup in THA compared with the reference values obtained from the image-free navigation system in a cadaveric experiment. Five hips of 5 embalmed whole-body cadavers were used in the study. Seven orthopedic surgeons (4 residents and 3 senior hip surgeons) participated in the study. All of the surgeons examined each of the 5 hips 3 times. The target angle was 38°/19° for operative inclination/anteversion angles, which corresponded to radiographic inclination/anteversion angles of 40°/15°. The simultaneous assessment using the navigation system showed mean±SD radiographic alignment angles of 39.4°±2.6° and 16.4°±2.6° for inclination and anteversion, respectively. Assessment of cup positioning based on Lewinnek's safe zone criteria showed all of the procedures (n=105) achieved acceptable alignment within the safe zone. A comparison of the performances by resident and senior hip surgeons showed no significant difference between the groups (P=.74 for inclination and P=.81 for anteversion). The iPhone/iPad technique examined in this study could achieve acceptable performance in determining cup alignment in THA regardless of the surgeon's expertise. [Orthopedics. 2016; 39(4):e621-e626.]. Copyright 2016, SLACK Incorporated.

  8. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK).

    PubMed

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of -0.75 D to 1.0 D ×175° in her right eye 1 month later. We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management.

  9. A Graphic Overlay Method for Selection of Osteotomy Site in Chronic Radial Head Dislocation: An Evaluation of 3D-printed Bone Models.

    PubMed

    Kim, Hui Taek; Ahn, Tae Young; Jang, Jae Hoon; Kim, Kang Hee; Lee, Sung Jae; Jung, Duk Young

    2017-03-01

    Three-dimensional (3D) computed tomography imaging is now being used to generate 3D models for planning orthopaedic surgery, but the process remains time consuming and expensive. For chronic radial head dislocation, we have designed a graphic overlay approach that employs selected 3D computer images and widely available software to simplify the process of osteotomy site selection. We studied 5 patients (2 traumatic and 3 congenital) with unilateral radial head dislocation. These patients were treated with surgery based on traditional radiographs, but they also had full sets of 3D CT imaging done both before and after their surgery: these 3D CT images form the basis for this study. From the 3D CT images, each patient generated 3 sets of 3D-printed bone models: 2 copies of the preoperative condition, and 1 copy of the postoperative condition. One set of the preoperative models was then actually osteotomized and fixed in the manner suggested by our graphic technique. Arcs of rotation of the 3 sets of 3D-printed bone models were then compared. Arcs of rotation of the 3 groups of bone models were significantly different, with the models osteotomized accordingly to our graphic technique having the widest arcs. For chronic radial head dislocation, our graphic overlay approach simplifies the selection of the osteotomy site(s). Three-dimensional-printed bone models suggest that this approach could improve range of motion of the forearm in actual surgical practice. Level IV-therapeutic study.

  10. Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

    PubMed

    Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa

    2012-08-01

    Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.

  11. Management of iatrogenic crystalline lens injury occurred during intravitreal injection.

    PubMed

    Erdogan, Gurkan; Gunay, Betul Onal; Unlu, Cihan; Gunay, Murat; Ergin, Ahmet

    2016-08-01

    To evaluate the approach to management of iatrogenic crystalline lens injury occurred during intravitreal injection (IVI). The patients who were managed operatively or followed-up without intervention after the iatrogenic lens injury due to IVI were included in the study. Capsular breaks remained either quiescent or resulted in cataract formation in the patients with inadvertent crystalline lens capsule damage. Phacoemulsification surgery was performed in patients with cataract formation with lower fluidic settings. A total of 9 cases included in the study. Seven cases underwent phacoemulsification with intraocular lens implantation. Two cases remained as quiescent lens injury during the follow-up. In 2 cases, dislocation of lens fragments occurred during phacoemulsification where pars plana vitrectomy was performed at the same session. After iatrogenic crystalline lens injury, capsular damage could remain quiescent or progress to cataract formation. Although phacoemulsification surgery can be performed with appropriate parameters, lens fragment dislocation can be observed in cases with traumatic lens damage secondary to IVI.

  12. Soft tissue-based surgical techniques for treatment of posterior shoulder instability.

    PubMed

    Castagna, Alessandro; Conti, Marco; Garofalo, Raffaele

    2017-01-01

    Posterior shoulder instability is a rare clinical condition that encompasses different degrees of severity including various possible pathologies involving the labrum, capsule, bony lesions, and even locked posterior dislocation. When focusing on soft tissue involvement, the diagnosis of posterior instability may be difficult to make because frequently patients report vague symptoms not associated with a clear history of traumatic shoulder dislocation. Pathological soft tissue conditions associated with posterior instability in most cases are related to posterior labral tear and/or posterior capsular detensioning/tear. The diagnosis can be facilitated by physical examination using specific clinical tests (i. e., jerk test, Kim test, and reinterpreted O'Brien test) together with appropriate imaging studies (i. e., magnetic resonance arthrography). Arthroscopy may help in a complete evaluation of the joint and allows for the treatment of soft tissue lesions in posterior instability. Caution is warranted in the case of concomitant posterior glenoid chondral defect as a potential cause of poor outcome after soft tissue repair in posterior instability.

  13. Hip Arthroscopy in Trauma: A Systematic Review of Indications, Efficacy, and Complications.

    PubMed

    Niroopan, Gavinn; de Sa, Darren; MacDonald, Austin; Burrow, Sarah; Larson, Christopher M; Ayeni, Olufemi R

    2016-04-01

    This systematic review explored the indications, efficacy, and complications of hip arthroscopy in the setting of trauma. Databases (PubMed, Medline, Embase, and Web of Science) were searched from database inception to March 2015 for studies using hip arthroscopy in trauma treatment. Systematic screening of eligible studies was undertaken in duplicate. The inclusion criteria included studies pertaining to arthroscopic intervention of all traumatic hip injuries. Abstracted data were organized in table format with descriptive statistics presented. From an initial search yield of 2,809 studies, 32 studies (25 case reports and 7 case series) satisfied the criteria for inclusion. A total of 144 patients (age range, 10 to 53 years) underwent hip arthroscopy for 6 indications associated with trauma: 8 patients for bullet extraction, 6 for femoral head fixation, 82 for loose body removal, 6 for acetabular fracture fixation, 20 for labral intervention, and 23 for ligamentum teres debridement. Patients were followed up postoperatively for a mean of 2.9 years (range, 8 days to 16 years). Successful surgery was achieved in 96% of patients. The rate of major complications (i.e., pulmonary embolism and abdominal compartment syndrome) was 1.4% (2 of 144); avascular necrosis, 1.4% (2 of 144); and nerve palsy, 0.7% (1 of 144). Hip arthroscopy appears effective and safe in the setting of trauma. These data should be interpreted with caution because of the low-quality evidence of the included studies. Surgeons should be aware of the potential complications such as abdominal compartment syndrome and thromboembolic events when performing hip arthroscopy in the setting of trauma. Level IV, systematic review of Level IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Development and psychometric properties of the Patient-Head Injury Participation Scale (P-HIPS) and the Patient-Head Injury Neurobehavioral Assessment Scale (P-HINAS): patient and family determined outcomes scales.

    PubMed

    Deb, Shoumitro; Bryant, Eleanor; Morris, Paul G; Prior, Lindsay; Lewis, Glyn; Haque, Sayeed

    2007-06-01

    To develop a measure to assess post-acute outcome following from traumatic brain injury (TBI) with particular emphasis on the emotional and the behavioral outcome. The second objective was to assess the test-retest reliability, internal consistency, and factor structure of the newly developed patient version of the Head Injury Participation Scale (P-HIPS) and Patient-Head Injury Neurobehavioral Scale (P-HINAS). Thirty-two TBI individuals and 27 carers took part in in-depth qualitative interviews exploring the consequences of the TBI. Interview transcripts were analyzed and key themes and concepts were used to construct the 49-item P-HIPS. A postal survey was then conducted on a cohort of 113 TBI patients to 'field test' the P-HIPS and the P-HINAS. All individual 49 items of the P-HIPS and their total score showed good test-retest reliability (0.93) and internal consistency (0.95). The P-HIPS showed a very good correlations with the Mayo Portland Adaptability Inventory-3 (MPAI-3) (0.87) and a moderate negative correlation with the Glasgow Outcome Scale-Extended (GOSE) (-0.51). Factor analysis extracted the following domains: 'Emotion/Behavior,' 'Independence/Community Living,' 'Cognition' and 'Physical'. The 'Emotion/Behavior' factor constituted the P-HINAS, which showed good internal consistency (0.93), test-retest reliability (0.91) and concurrent validity with MPAI subscale (0.82). Both the P-HIPS and the P-HINAS show strong psychometric properties. The qualitative methodology employed in the construction stage of the questionnaires provided good evidence of face and content validity.

  15. Development and psychometric properties of the Patient-Head Injury Participation Scale (P-HIPS) and the Patient-Head Injury Neurobehavioral Assessment Scale (P-HINAS): patient and family determined outcomes scales

    PubMed Central

    Deb, Shoumitro; Bryant, Eleanor; Morris, Paul G; Prior, Lindsay; Lewis, Glyn; Haque, Sayeed

    2007-01-01

    Objective To develop a measure to assess post-acute outcome following from traumatic brain injury (TBI) with particular emphasis on the emotional and the behavioral outcome. The second objective was to assess the test–retest reliability, internal consistency, and factor structure of the newly developed patient version of the Head Injury Participation Scale (P-HIPS) and Patient-Head Injury Neurobehavioral Scale (P-HINAS). Method Thirty-two TBI individuals and 27 carers took part in in-depth qualitative interviews exploring the consequences of the TBI. Interview transcripts were analyzed and key themes and concepts were used to construct the 49-item P-HIPS. A postal survey was then conducted on a cohort of 113 TBI patients to ‘field test’ the P-HIPS and the P-HINAS. Results All individual 49 items of the P-HIPS and their total score showed good test–retest reliability (0.93) and internal consistency (0.95). The P-HIPS showed a very good correlations with the Mayo Portland Adaptability Inventory-3 (MPAI-3) (0.87) and a moderate negative correlation with the Glasgow Outcome Scale-Extended (GOSE) (−0.51). Factor analysis extracted the following domains: ‘Emotion/Behavior,’ ‘Independence/Community Living,’ ‘Cognition’ and ‘Physical’. The ‘Emotion/Behavior’ factor constituted the P-HINAS, which showed good internal consistency (0.93), test–retest reliability (0.91) and concurrent validity with MPAI subscale (0.82). Conclusions Both the P-HIPS and the P-HINAS show strong psychometric properties. The qualitative methodology employed in the construction stage of the questionnaires provided good evidence of face and content validity. PMID:19300568

  16. To Screen or Not to Screen? A Decision Analysis of the Utility of Screening for Developmental Dysplasia of the Hip

    PubMed Central

    Mahan, Susan T.; Katz, Jeffrey N.; Kim, Young-Jo

    2009-01-01

    Background: The United States Preventive Services Task Force recently determined that they could not recommend any screening strategies for developmental dysplasia of the hip. Disparate findings in the literature and treatment-related problems have led to confusion about whether or not to screen for this disorder. The purpose of the present study was to determine, with use of expected-value decision analysis, which of the following three strategies leads to the best chance of having a non-arthritic hip by the age of sixty years: (1) no screening for developmental dysplasia of the hip, (2) universal screening of newborns with both physical examination and ultrasonography, or (3) universal screening with physical examination but only selective use of ultrasonography for neonates considered to be at high risk. Methods: Developmental dysplasia of the hip, avascular necrosis, and the treatment algorithm were carefully defined. The outcome was determined as the probability of any neonate having a non-arthritic hip through the age of sixty years. A decision tree was then built with decision nodes as described above, and chance node probabilities were determined from a thorough review of the literature. Foldback analysis and sensitivity analyses were performed. Results: The expected value of a favorable hip outcome was 0.9590 for the strategy of screening all neonates with physical examination and selective use of ultrasonography, 0.9586 for screening all neonates with physical examination and ultrasonography, and 0.9578 for no screening. A lower expected value implies a greater risk for the development of osteoarthritis as a result of developmental dysplasia of the hip or avascular necrosis; thus, the optimum strategy was selective screening. This model was robust to sensitivity analysis, except when the rate of missed dysplasia rose as high as 4/1000 or the rate of treated hip subluxation/dislocation was the same; then, the optimum strategy was to screen all neonates with both physical examination and ultrasonography. Conclusions: Our decision analytic model indicated that the optimum strategy, associated with the highest probability of having a non-arthritic hip at the age of sixty years, was to screen all neonates for hip dysplasia with a physical examination and to use ultrasonography selectively for infants who are at high risk. Additional data on the costs and cost-effectiveness of these screening policies are needed to guide policy recommendations. Level of Evidence: Economic and decision analysis Level II. See Instructions to Authors for a complete description of levels of evidence. PMID:19571094

  17. Surgical Management and Hearing Outcome of Traumatic Ossicular Injuries.

    PubMed

    Delrue, Stefan; Verhaert, Nicolas; Dinther, Joost van; Zarowski, Andrzej; Somers, Thomas; Desloovere, Christian; Offeciers, Erwin

    2016-12-01

    The purpose of this study was to investigate etiological, clinical, and pathological characteristics of traumatic injuries of the middle ear ossicular chain and to evaluate hearing outcome after surgery. Thirty consecutive patients (31 ears) with traumatic ossicular injuries operated on between 2004 and 2015 in two tertiary referral otologic centers were retrospectively analyzed. Traumatic events, clinical features, ossicular lesions, treatment procedures, and audiometric results were evaluated. Air conduction (AC), bone conduction (BC), and air-bone gap (ABG) were analyzed preoperatively and postoperatively. Amsterdam Hearing Evaluation Plots (AHEPs) were used to visualize the individual hearing results. The mean age at the moment of trauma was 27.9±17.1 years (range, 2-75 years) and the mean age at surgery was 33.2±16.3 years (range, 5-75 years). In 10 cases (32.3%), the injury occurred by a fall on the head and in 9 (29.0%) by a traffic accident. Isolated luxation of the incus was observed in 8 cases (25.8%). Dislocation of the stapes footplate was seen in 4 cases (12.9%). The postoperative ABG closure to within 10 and 20 dB was 30% and 76.7%, respectively. Ossicular chain injury by direct or indirect trauma can provoke hearing loss, tinnitus, and vertigo. As injuries are heterogeneous, they require a tailored surgical approach. In this study, the overall hearing outcome after surgical repair was favorable.

  18. Intra- and extra-capsular hip fractures in the elderly: Two different pathologies?

    PubMed

    Dinamarca-Montecinos, J L; Prados-Olleta, N; Rubio-Herrera, R; Castellón-Sánchez del Pino, A; Carrasco-Buvinic, A

    2015-01-01

    To compare intracapsular (IC) and extracapsular (EC) hip fractures (HIF) in elderly patients in order to determine if they are different pathologies. Longitudinal, observational, descriptive, analytical prospective design, using a non-probabilistic sample from a full sample collection with 647 subjects (male and female), of 60 or more years old, admitted with HIF to the Department of Orthopedics and Traumatology of the Hospital, between January 1, 2010 and December 31, 2012. Follow-up was for 1 year post HIF. Socio-demographic, etiological, developmental, therapeutic and prognostic variables are compared. This is the first study on this subject with Latin American population. EC HIF incidence was superior to IC, contrary to that published in European/American populations. There are significant differences in etiological variables (χ(2)=6.34, p<0.042), with traumatic etiology in EC and non-traumatic in IC. There are also differences in therapeutic interventions performed (osteosynthesis for EC, arthroplasty for IC), with the decision on not to operate being lower in IC (both p<0.0000). The variables associated with the decision on not to perform surgery are age, etiology and postoperative mortality. The results are similar to other studies, adding the IC association with non-traumatic origin, in particular the trend of statistical association between IC and non-primary osteoporotic pathology (neoplasms, renal osteodystrophy, primary hyperparathyroidism). A further analysis was performed on the differences between Latin American and European/American populations in the incidence of either type of HIF. There are important etiological and therapeutic differences between IC and EC HIF; therefore it would be advisable to consider them as distinct disease entities. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  19. Marijuana use and mortality following orthopedic surgical procedures.

    PubMed

    Moon, Andrew S; Smith, Walter; Mullen, Sawyer; Ponce, Brent A; McGwin, Gerald; Shah, Ashish; Naranje, Sameer M

    2018-03-20

    The association between marijuana use and surgical procedures is a matter of increasing societal relevance that has not been well studied in the literature. The primary aim of this study is to evaluate the relationship between marijuana use and in-hospital mortality, as well as to assess associated comorbidities in patients undergoing commonly billed orthopedic surgeries. The National Inpatient Sample (NIS) database from 2010 to 2014 was used to determine the odds ratios for the associations between marijuana use and in-hospital mortality, heart failure (HF), stroke, and cardiac disease (CD) in patients undergoing five common orthopedic procedures: hip (THA), knee (TKA), and shoulder arthroplasty (TSA), spinal fusion, and traumatic femur fracture fixation. Of 9,561,963 patients who underwent one of the five selected procedures in the four-year period, 26,416 (0.28%) were identified with a diagnosis of marijuana use disorder. In hip and knee arthroplasty patients, marijuana use was associated with decreased odds of mortality compared to no marijuana use (p<0.0001), and increased odds of HF (p = 0.018), stroke (p = 0.0068), and CD (p = 0.0123). Traumatic femur fixation patients had the highest prevalence of marijuana use (0.70%), which was associated with decreased odds of mortality (p = 0.0483), HF (p = 0.0076), and CD (p = 0.0003). For spinal fusions, marijuana use was associated with increased odds of stroke (p<0.0001) and CD (p<0.0001). Marijuana use in patients undergoing shoulder arthroplasty was associated with decreased odds of mortality (p<0.001) and stroke (p<0.001). In this study, marijuana use was associated with decreased mortality in patients undergoing THA, TKA, TSA and traumatic femur fixation, although the significance of these findings remains unclear. More research is needed to provide insight into these associations in a growing surgical population.

  20. Validation of fragility fractures in primary care electronic medical records: A population-based study.

    PubMed

    Martinez-Laguna, Daniel; Soria-Castro, Alberto; Carbonell-Abella, Cristina; Orozco-López, Pilar; Estrada-Laza, Pilar; Nogues, Xavier; Díez-Perez, Adolfo; Prieto-Alhambra, Daniel

    2017-11-28

    Electronic medical records databases use pre-specified lists of diagnostic codes to identify fractures. These codes, however, are not specific enough to disentangle traumatic from fragility-related fractures. We report on the proportion of fragility fractures identified in a random sample of coded fractures in SIDIAP. Patients≥50 years old with any fracture recorded in 2012 (as per pre-specified ICD-10 codes) and alive at the time of recruitment were eligible for this retrospective observational study in 6 primary care centres contributing to the SIDIAP database (www.sidiap.org). Those with previous fracture/s, non-responders, and those with dementia or a serious psychiatric disease were excluded. Data on fracture type (traumatic vs fragility), skeletal site, and basic patient characteristics were collected. Of 491/616 (79.7%) patients with a registered fracture in 2012 who were contacted, 331 (349 fractures) were included. The most common fractures were forearm (82), ribs (38), and humerus (32), and 225/349 (64.5%) were fragility fractures, with higher proportions for classic osteoporotic sites: hip, 91.7%; spine, 87.7%; and major fractures, 80.5%. This proportion was higher in women, the elderly, and patients with a previously coded diagnosis of osteoporosis. More than 4 in 5 major fractures recorded in SIDIAP are due to fragility (non-traumatic), with higher proportions for hip (92%) and vertebral (88%) fracture, and a lower proportion for fractures other than major ones. Our data support the validity of SIDIAP for the study of the epidemiology of osteoporotic fractures. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  1. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    PubMed

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.

  2. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    PubMed

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and for dislocation (8 vs. 1, P=0.031). Mean PMA scores at last follow-up were comparable in the AVN group (17.65±1.27 [range, 10-18]) and osteoarthritis group (17.59±1.32 [range, 14-18]) (P=0.139). Osseointegration was also similar in the two groups: global Engh score, 26.51±1.81 (range, 14-27) for AVN and 26.84±0.91 (range, 19.5-27) for osteoarthritis (P=0.065); femoral ARA score, 5.83±0.46 (range, 3-6) for AVN and 5.90±0.42 (range, 3-6) for osteoarthritis (P=0.064); and cup ARA score, 5.74±0.67 (range, 3-6) for AVN and 5.78±0.66 (range, 3-6) for osteoarthritis (P=0.344). Survival in this study was good and consistent with recent data on AVN, with no difference between AVN and osteoarthritis. Revisions for any cause or for dislocation were more common after THA for AVN. Functional outcomes were similar in the AVN and osteoarthritis groups. An anatomical cementless prosthesis combined with metal-on-metal 28-mm bearing provides durable good outcomes. III, non-randomized comparison of two prospective cohorts. Published by Elsevier Masson SAS.

  3. [CLINICAL APPLICATION OF THREE DIMENSIONAL PRINTED NAVIGATION TEMPLATES FOR TREATMENT OF OSTEONECROSIS OF FEMORAL HEAD WITH PEDICLED ILIAC BONE GRAFT].

    PubMed

    Yu, Kaifu; Xu, Yongqing; Tan, Hongbo; He, Xiaoqing; Cai, Dixin; Zhou, Tianhua; Luo, Haotian; Duan, Jiazhang

    2016-03-01

    To investigate the feasibility and early effectiveness to treat osteonecrosis of the femoral head (ONFH) with pedicled iliac bone graft assisted by individual digital design and three dimensional (3D) printed navigation templates. Between February and June 2014, 15 patients (24 hips) with ONFH underwent pedicled iliac bone graft assisted by individual digital design and 3D printed navigation templates. There were 11 males (17 hips) and 4 females (7 hips) with a mean age of 38 years (range, 18-56 years) and a mean disease duration of 7.5 months (range, 1-24 months); the left hip was involved in 2 cases, the right hip in 4 cases, and both hips in 9 cases. There were 7 cases (12 hips) of steroid-induced ONFH, 5 cases (8 hips) of alcohol-induced ONFH, 1 case (1 hip) of traumatic ONFH, and 2 cases (3 hips) of idiopathic ONFH. The preoperative Harris score was 56.60 ± 6.97. According to Association Research Circulation Osseous (ARCO) staging system, 5 hips were classified as stage IIB, 8 hips as stage IIC, 6 hips as stage IIIB, and 5 hips as stage IIIC. The navigation templates were designed and printed to assist accurate location and debridement of necrosis area according to preoperative CT scanning at the beginning of pedicled iliac bone grafting procedure. The mean operation time was 135 minutes (range, 120-160 minutes), mean amount of bleeding was 255 mL (range, 200-300 mL). All the wounds healed primarily, no complication of deep vein thrombosis or infection was observed. All patients were followed up 12-16 months (mean, 14 months). The location of necrosis area was in accordance with preoperative design, which was removed completely without penetration of joint surface, pedicled iliac bone graft was performed at the right site according to postoperative imaging examination. Radiographically, graft fusion was achieved at 2.7 months (range, 2-3 months) in all patients. All the hips had no collapse during follow-up. Hip pain was relieved, and range of motion was improved. The Harris score was significantly improved to 89.53 ± 5.83 at last follow-up (t = 14.3 19, P = 0.000). The results were excellent in 12 hips, good in 10 hips, and fair in 2 hips according to Harris score standard. Pedicled iliac bone graft assisted by individual digital design and 3D printed navigation templates for treatment of adult ONFH has the advantages of accurate location and complete debridement of necrosis area, so satisfactory results can be obtained.

  4. Bilateral avascular necrosis of the femoral head due to the use of heroin: A case report.

    PubMed

    Ozkunt, Okan; Sarıyılmaz, Kerim; Sungur, Mustafa; Ilen, Ferhat; Dikici, Fatih

    2015-01-01

    Femoral head avascular necrosis is caused by disruption of the blood supply of the femoral head, which finally results in hip dysfunction. Non traumatic osteonecrosis may related with corticosteroid use, alcohol abuse, SLE, hemoglobinopathies or exposure to cytotoxic agents. But avascular necrosis of the femoral head (ANFH) due to heroin use is a rare condition. We report a patient with bilateral ANFH due to heroin use treated by simultaneous bilateral hip arthroplasty. 37 year-old male patient presented with bilateral hip pain that had been occurring for four years. The patient had no history of smoking, excessive drinking, using corticosteroid and the other drugs or trauma but used heroin for 10 years. In clinic and radiologic examination indicated advanced degenerative changes on both hip due to femoral head avascular necrosis. The patient was treated with simultaneous bilateral total hip arthroplasty. After 6 months postoperatively the active hip range of motion was painless. Avascular femoral head necrosis caused by the using of heroin is rare. Ultimately, osteonecrosis of the femoral head occurs through one final common pathway, which is decreased blood flow to the femoral head that leads bone ischemia and death. But it is still unknown that heroin's systemic effects. Intravenous drug use more as a serious problem for today. There is a need for comprehensive studies to demonstrate effects of heroin on bone and vascularity metabolism. Heroin use will be important problem for population. That's why is crucial to understand the effect of heroin. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Acromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture - A Case Report.

    PubMed

    Sharma, Naveen; Mandloi, Avinash; Agrawal, Ashish; Singh, Shailendra

    2016-01-01

    The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to the best of our knowledge, this is the first case report to describe an acromioclavicular dislocation with ipsilateral mid shaft clavicle, mid shaft humerus and coracoid process fracture. Fractures of the humerus and clavicle along with the acromioclavicular joint dislocation were fixed at the same setting. A 65-year-old male met with a high velocity road traffic accident. Plain radiographs showed displaced mid third clavicle fracture with acromioclavicular joint dislocation with mid shaft humerus fracture. Surgical fixation was planned for humerus with interlocking nail, clavicle with locking plate and acromioclavicular joint with reconstruction of coracoclavicular ligaments. Intraoperatively, coracoid process was found to have a comminuted fracture. The operative plan had to be changed on table as coracoclavicular fixation was not possible. So acromioclavicular joint fixation was done using tension band wiring and the coracoclavicular ligament was repaired using a 2-0 ethibond. The comminuted coracoid fracture was managed conservatively. K wires were removed at 6 weeks. Early mobilization was started. In acromioclavicular joint injuries, clavicle must be evaluated for any injury. Although it is more commonly associated with distal clavicle fractures, it can be associated with middle third clavicle fractures. As plain radiographs, AP view are most of the times insufficient for viewing integrity of coracoid process, either special views like Stryker notch or CT scan may help in diagnosing such concealed injuries. When associated with fractures of the humerus and clavicle, anatomical restoration of acromioclavicular joint along with anatomical reduction and a rigid fixation of associated fractures is essential. Proper rehabilitation protocol is a must for achieving promising results. In our case, we were able to achieve a stable surgical fixation of both the fractures as well as AC joint, which enabled us to start early joint mobilization and rehabilitation.

  6. Vitreous vascular endothelial growth factor concentrations in proliferative diabetic retinopathy versus proliferative vitreoretinopathy.

    PubMed

    Citirik, Mehmet; Kabatas, Emrah Utku; Batman, Cosar; Akin, Kadir Okhan; Kabatas, Naciye

    2012-01-01

    To assess vitreous vascular endothelial growth factor (VEGF) concentrations in proliferative diabetic retinopathy (PDR) in comparison to proliferative vitreoretinopathy (PVR). Vitreous samples were collected from 69 eyes of 69 patients with traumatic lens dislocation (n = 10), grade B PVR with rhegmatogenous retinal detachment (n = 13), grade C PVR with rhegmatogenous retinal detachment (n = 14), PDR with vitreous hemorrhage (n = 18), and PDR with vitreous hemorrhage and tractional retinal detachment (n = 14). Vitreous fluid samples were obtained at vitrectomy, and the levels of VEGF were measured by enzyme-linked immunosorbent assay. The mean vitreous level of VEGF was 15.14 ± 5.22 pg/ml in eyes with grade B PVR, 99.15 ± 38.58 pg/ml in eyes with grade C PVR, 4,534.01 ± 1,193.28 pg/ml in eyes with vitreous hemorrhage secondary to PDR, 5,157.29 ± 969.44 pg/ml in eyes with vitreous hemorrhage and tractional retinal detachment secondary to PDR, and 16.19 ± 5.76 pg/ml in eyes of the control group with traumatic lens dislocation. Vitreous VEGF concentrations were significantly higher in the patients with grade C PVR, PDR with vitreous hemorrhage and PDR with vitreous hemorrhage and tractional retinal detachment in comparison to the control patients (p < 0.05). A significant alteration was not observed in patients with grade B PVR (p = 0.55). Vitreous VEGF concentrations are increased in PDR and grade C PVR. The high VEGF concentrations could suggest a possible effect of VEGF on advanced PVR. Copyright © 2011 S. Karger AG, Basel.

  7. Management of dislocated intraocular lenses with iris suture.

    PubMed

    Faria, Mun Y; Ferreira, Nuno P; Canastro, Mario

    2017-01-19

    Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of logMAR units. The mean visual acuity improvement was 4.08 ± 5.33 lines on the logMAR scale. In this study, every IOL was stable at the last follow-up. As late complications, macular edema occurred in 1 patient and retinal detachment occurred in 2 patients. There were no cases of endophthalmitis. Iris suture fixation of subluxated IOL is a good treatment option for eyes with dislocated IOLs, leading to long-term stability of the IOL. The advantage of this procedure is using the same IOL in a closed eye surgery. No astigmatic difference is expected as no large corneal incision is needed.

  8. [Bone surgery for unstable hips in patients with cerebral palsy].

    PubMed

    Poul, J; Pesl, M; Pokorná, M

    2004-01-01

    The aim of this retrospective study was to compare the efficacy of femoral osteotomy alone with that of osteotomy combined with an acetabular procedure in patients with unstable hips due to spastic cerebral palsy. Sixty-one hip joints in 50 patients who had shown distinct subluxation or dislocation of the joint were operated on. Eleven patients underwent bilateral surgery. Before bone surgery, soft-tissue release involving both the flexors and adductors was performed on 19 hips. Femoral osteotomy alone was performed on 29 hip joints and combined femoral and pelvic osteotomy was carried out on 32 joints.Twelve resections of the proximal femur in seven patients were evaluated as a separate group. All treated hip joints were assessed by clinical and radiographic examination at a follow-up of more than 5 years. The skiagraphs taken in a strictly neutral position of the lower limbs before surgery and at the final examination were evaluated on the basis of Reimers's migration index and Wiberg's centre-edge angle. The locomotor abilities of each child were categorized according to the Vojta scoring system for locomotor development. The range of motion in the treated hip joint was assessed using the standard S. F. T. R. method. The results obtained were statistically analyzed by the Kruskal- Wallis, one-way ANOVA test. A comparison of the results of femoral osteotomy alone with those of combined femoral and pelvic osteotomy showed that the post-operative values of the migration index and centre-edge angle, as compared with the pre-operative ones, were statistically higher (p<0.05) in the latter. In a long-term perspective, the surgery had no adverse effects on a natural development of locomotor abilities of the child. The children had higher scores by the modified Vojta rating system. There was no change in the range of motion in the treated hip joints after the operation. In 28, out of the 32 joints treated by combined femoral and pelvic osteotomy, Salter osteotomy was performed and it showed a high efficacy in providing hip joint stability. The main emphasis during surgery was placed on the maximum acetabular rotation laterally. Femoral osteotomy alone was less effective in providing hip joint stability; in addition, in order to achieve this, tilting of the proximal fragment to a varus position was generally higher than in combined operations. In three patients this treatment resulted in fixed adduction of the hip joint with negative consequences for movement. In the treatment of unstable hip joints a combination of varus derotation femoral osteotomy and pelvic osteotomy provides better containment of the joint than femoral osteotomy alone.

  9. Discontinuation of Plavix® (clopidogrel) for hip fracture surgery. A systematic review of the literature.

    PubMed

    Mattesi, L; Noailles, T; Rosencher, N; Rouvillain, J-L

    2016-12-01

    The elderly population is increasing worldwide, associated with an increase in diseases related to aging, such as hip fractures. These patients are sometimes treated with clopidogrel. There are no arguments at present to clearly determine the risk/benefit ratio of early surgical management of traumatic hip fractures in patients treated with clopidogrel (perioperative blood loss, postoperative complications). The goal of this systematic review of the literature was to show that early surgical management (<48h) of patients treated with clopidogrel does not increase postoperative morbidity or mortality. Systematic review of the literature: level of evidence IV. A bibliographic search was performed in July 2015 in PubMed, Embase and Cochrane databases using the MeSh keywords "Clopidogrel or Plavix ® " AND "hip fracture". Two of the authors analyzed 48 articles based on the title and abstract. Twenty-one articles were selected and read completely with an analysis of the references. Nine articles were chosen. Early surgical management (<48h) of patients receiving clopidogrel did not increase mortality at 30days, 3months or 1 year (between 25 and 30% mortality at 1 year) and did not result in an increase in perioperative bleeding. The risk/benefit ratio of early surgical management of patients with hip fractures receiving clopidogrel is good; morbidity and mortality are not increased in these patients if surgery is performed immediately or less than 48h after admission. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Management of shoulder instability in a military population.

    PubMed

    Pimple, M K; DaCosta, A; Clasper, J C

    2008-03-01

    Recurrent instability is common after shoulder dislocation in the young, particularly those engaged in physical jobs or sport. The management of recurrent traumatic shoulder instability is predominantly operative. However, the best method of surgery i.e. open or arthroscopic is still a matter of debate. We have developed an algorithm to decide on the choice of surgery and the aim of this study is to report this and compare the two different groups of military patients. A retrospective review of all shoulder stabilisations performed on military personnel, by a single surgeon, between August 2004 and August 2005 at a district general hospital serving both military and civilian population was undertaken. The presentation, clinical and operative findings were noted and compared in the groups treated by arthroscopic or open stabilisation. Using our protocol 39 shoulder stabilisations were performed in military personnel. Of the shoulders, 25 (64%) underwent arthroscopic and 14 (36%) underwent open stabilisation. The indication for surgery was more than 2 episodes of shoulder dislocation. Open surgery was found to be more common in those who had their first dislocation at a younger age. Bilateral shoulder laxity was the most common indication to choose the open method. Both open and arthroscopic stabilisation gave good results in the high demand military population. Only one patient had recurrent instability after arthroscopic procedure. However, this was not statistically significant when compared with open stabilisation.

  11. [Treatment of adult avascular necrosis of femoral head by transplanting iliac bone flap with deep iliac circumflex vessels and cancellous bone].

    PubMed

    Yu, Zhiliang; Zhang, Ning; Yang, Yi; Wang, Bin; Gao, Shuo; Zhao, Xiaoyong

    2013-07-01

    To investigate the effectiveness of transplanting iliac bone flap with deep iliac circumflex vessels and cancellous bone for the treatment of adult avascular necrosis of the femoral head (ANFH). A retrospective analysis was made on the clinical data of 685 patients (803 hips) with ANFH, who underwent iliac bone flap transplantation with deep iliac circumflex vessels and cancellous bone between March 2002 and January 2010. There were 489 males (580 hips) and 196 females (223 hips) with a mean age of 40.4 years (range, 18-63 years), including 567 unilateral cases (303 left hips and 264 right hips) and 118 bilateral cases. The causes of ANFH included alcohol-induced in 223 cases, steroid-induced in 179 cases, alcohol + steroid-induced in 21 cases, traumatic in 136 cases, acetabular dysplasia in 8 cases, bone cyst in 5 cases, septic arthritis in 2 cases, joint tuberculosis in 3 cases, rheumatoid arthritis in 5 cases, and idiopathic in 103 cases. According to Steinberg staging, 211 hips were rated as stage II, 513 hips as stage III, and 79 hips as stage IV. The preoperative Harris hip score was 60.30 +/- 7.02. Fat necrosis occurred in 2 cases after operation, primary healing of incision was obtained in the other cases; delayed infection, lower extremity deep vein thrombosis, and pulmonary embolism occurred in 2 cases, respectively. All patients were followed up 36-60 months (mean, 49 months). Harris hip score at last follow-up (83.50 +/- 7.31) was significantly higher than that at preoperation (t= -2 266.980, P=0.000), and the scores were significantly higher than those at preoperation in different stages (P < 0.05). The results were excellent in 523 hips, good in 185 hips, fair in 65 hips, and poor in 30 hips, and the excellent and good rate was 88.2%. X-ray examination showed bone fusion of transplanted bone flap and bone graft with an average of 4.2 months (range, 3-6 months); according to Steinberg staging, imaging stable rate was 78.3% (629/803) at last follow-up. Iliac bone flap transplantion with deep iliac circumflex vessels and cancellous bone has the advantages of complete decompression of the femoral head, exact flap blood supply, improved blood supply of the femoral head, new support for the femoral head, and participation of osteoinductive effect for the treatment of adult ANFH, so it is an effective treatment for the retention of the femoral head.

  12. Development and psychometric properties of the Carer - Head Injury Neurobehavioral Assessment Scale (C-HINAS) and the Carer - Head Injury Participation Scale (C-HIPS): patient and family determined outcome scales.

    PubMed

    Deb, Shoumitro; Bryant, Eleanor; Morris, Paul G; Prior, Lindsay; Lewis, Glyn; Haque, Sayeed

    2007-06-01

    Develop and assess the psychometric properties of the Carer - Head Injury Participation Scale (C-HIPS) and its biggest factor the Carer - Head Injury Neurobehavioral Assessment Scale (C-HINAS). Furthermore, the aim was to examine the inter-informant reliability by comparing the self reports of individuals with traumatic brain injury (TBI) with the carer reports on the C-HIPS and the C-HINAS. Thirty-two TBI individuals and 27 carers took part in in-depth qualitative interviews exploring the consequences of the TBI. Interview transcripts were analysed and key themes and concepts were used to construct a 49-item and 58-item patient (Patient - Head Injury Participation Scale [P-HIPS]) and carer outcome measure (C-HIPS) respectively, of which 49 were parallel items and nine additional items were used to assess carer burden. Postal versions of the P-HIPS, C-HIPS, Mayo Portland Adaptability Inventory-3 (MPAI-3), and the Glasgow Outcome Scale-Extended (GOSE) were completed by a cohort of 113 TBI individuals and 80 carers. Data from a sub-group of 66 patient/carer pairs were used to compare inter-informant reliability between the P-HIPS and the C-HIPS, and the P-HINAS and the C-HINAS respectively. All individual 49 items of the C-HIPS and their total score showed good test-retest reliability (0.95) and internal consistency (0.95). Comparisons with the MPAI-3 and GOSE found a good correlation with the MPAI-3 (0.7) and a moderate negative correlation with the GOSE (-0.6). Factor analysis of these items extracted a 4-factor structure which represented the domains 'Emotion/Behavior' (C-HINAS), 'Independence/Community Living', 'Cognition', and 'Physical'. The C-HINAS showed good internal consistency (0.92), test-retest reliability (0.93), and concurrent validity with one MPAI subscale (0.7). Assessment of inter-informant reliability revealed good correspondence between the reports of the patients and the carers for both the C-HIPS (0.83) and the C-HINAS (0.82). Both the C-HINAS and the C-HIPS show strong psychometric properties. The qualitative methodology employed in the construction stage of the questionnaires provided good evidence of face and content validity. Comparisons between the P-HIPS and the C-HIPS, and the P-HINAS and the C-HINAS indicated high levels of agreement suggesting that in situations where the patient is unable to provide self-reports, information provided by the carer could be used.

  13. Chronological changes in functional cup position at 10 years after total hip arthroplasty.

    PubMed

    Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko

    2017-09-19

    This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p<0.01). The maximum postoperative change in F-Ant was 17.0° anteriorly; 12 cases (21%) showed a postoperative change in F-Ant by >10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.

  14. High-impact sport after hip resurfacing: The Ironman triathlon.

    PubMed

    Girard, J; Lons, A; Pommepuy, T; Isida, R; Benad, K; Putman, S

    2017-09-01

    Returning to high-impact sport is an increasingly frequent functional demand following hip replacement. The literature, however, is sparse on the subject and nonexistent regarding triathlon. We therefore conducted a retrospective study of hip resurfacing in triathlon players, to determine: (1) whether it is possible to return to this kind of sport; (2) if so, whether it is possible to return to the same level; and (3) how a resurfaced hip behaves under these conditions. Hip resurfacing allows return to competition level in long-distance triathlon. A single-center single-operator retrospective study included patients undergoing hip resurfacing with the Conserve Plus implant inserted through a posterolateral approach, who had ceased long-distance triathlon practice due to osteoarthritis of the hip. Fifty-one of the 1688 patients undergoing resurfacing during the inclusion period were long-distance triathlon players. The series comprised 48 patients: 51 implants; 43 male, 5 female; mean age, 44.8 years (range, 28.2-58.9 years). At a mean 4.7 years' follow-up (range, 2.2-7.6 years), all clinical scores showed significant improvement; Merle d'Aubigné and Harris scores rose respectively from 12.3 (5-16) and 42 (37-56) preoperatively to 17.5 (13-18) and 93.2 (73-100) (P<0.001). There were no cases of dislocation or implant revision. Forty-five patients returned to sport (94%). Rates of return to swimming, cycling and running were respectively 38/48 (79%), 41/48 (85%) and 33/48 (69%). Preoperatively, all patients had taken part in at least 1 competition: 29 with distance=70.3km and 19 with distance=140.6km. At follow-up, 28 patients had taken part in an Ironman competition: 21 with distance=70.3km and 7 with distance=140.6km. Mean competition performance did not differ between pre and postoperative periods. Return-to-sport rates were good following hip resurfacing. Non-impact sports (swimming, cycling) predominated postoperatively, whereas the rate of impact sport (running) diminished. Return to competition-level sport (extreme triathlon) was possible for 28/48 patients (58%). Implant survival seemed unaffected by this high-impact sports activity at a mean 4.7 years' follow-up. IV, retrospective, non-controlled. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Hip surgery and its evidence base: progress over a decade?

    PubMed

    Hasan, Kamrul; Shankar, Shivakumar; Sharma, Aadhar; Carter, Alison; Zaidi, Razi; Cro, Suzie; Skinner, John; Goldberg, Andy

    2016-12-01

    The burden of traumatic and elective hip surgery is set to grow. With an increasing number of techniques and implants against the background of an aging population, the emphasis on evidence-based treatment has never been greater. The purpose of this study was to assess changes in the levels of evidence in the hip literature over a decade. Articles pertaining to hip surgery from the years 2000 and 2010 in Hip International, Journal of Arthroplasty, Journal of Bone and Joint Surgery and The Bone and Joint Journal were analysed. Articles were ranked by a five-point level of evidence scale and by type of study, according to guidelines from the Centre for Evidence-based Medicine. 531 articles were analysed from 48 countries. The kappa value for the inter-observer reliability showed excellent agreement between the reviewers for study type (κ = 0.956, P < 0.01) and for levels of evidence (κ = 0.772, P < 0.01). Between 2000 and 2010, the overall percentage of high-level evidence (levels I and II) studies more than doubled (12 to 31 %, P < 0.001). The most frequent study type was therapeutic; the USA and UK were the largest producers of published work in these journals, with contributions from other countries increasing markedly over the decade. There has been a significant increase in high levels of evidence in hip surgery over a decade (P < 0.001). We recommend that all orthopaedic journals consider implementing compulsory declaration by authors of the level of evidence to help enhance quality of evidence. Level 2: economic and decision analysis.

  16. A prospective cohort study of the clinical presentation of non-traumatic osteonecrosis of the femoral head: spine and knee symptoms as clinical presentation of hip osteonecrosis.

    PubMed

    Hauzeur, Jean-Philippe; Malaise, Michel; de Maertelaer, Viviane

    2016-07-01

    To study the clinical presentation of femoral head osteonecrosis (ONFH). Publications dedicated to this aspect of ONFH are rare. Our aim was to systematically collect and describe the clinical data. A prospective survey was conducted in a cohort of ONFH recruited from a dedicated clinic for osteonecrosis. The history of symptoms, medical management, and physical findings were obtained from 88 patients suffering from 125 ONFH. Subgroups were formed: bilateral versus unilateral ONFH, radiological stages 1-2 (pre-fractured) versus fractured stage 3 versus stage 4. ONFH was bilateral in 63 %, especially in corticosteroid users and in sickle-cell cases. These patients were younger but had similar BMIs compared to the unilateral cases. The pain was mechanical in 79 % of hips and inflammatory in 21 %. Acute pain at the onset was present in 55 % of hips. The localization of this pain was variable, including in the groin, the buttocks, or diffused in the lower limbs. A limp was present in 50 % of the patients, only when one hip was painful. The physical examination of the hip was normal in 31 %, especially in stages 1-2 (55 %). The diagnosis delay was 12 months, with inadequate medical management in 51 % of patients. In ONFH cases, no typical clinical pattern was found. The clinical presentation was very variable, sometimes having spine or knee symptoms with a normal physical examination of the hip. ONFH should be systematically suspected in cases of onset of pain in the pelvis, buttocks, groin, and lower limbs.

  17. Occupational accidents in professional dancers with regard to different professional dance styles.

    PubMed

    Wanke, Eileen M; Mill, Helmgard; Arendt, Michael; Wanke, Alice; Koch, Franziska; Groneberg, David A

    2014-01-01

    The term "professional dance" comprises various dance styles. There are no studies which investigated work related traumatic injuries with regard to five different dance styles. To define dance-style related differences of traumatic injuries. The basis for the evaluation were the occupational injuries of professional dancers of six theaters (n=1339; f: n=658, m: n=681) and one State Ballet School (n=612; f:n=421, m: n=191). Independent of the dance style, the lower extremity (leg and hip) is the most frequently injured anatomical region (p< 0.001). The more dancers move away from the classical dance technique, the more traumatic head/neck injuries increase (p<0.001). Injury patterns and injured structures also show differences subject to dance styles (p< 0.001). In classical dance the most commonly sustained injuries are due to intrinsic factors with the significance of extrinsic factors increasing the more dancers diverge from defined classical dance techniques. The results shown in the study clarify the enormous dance-style related differences in traumatic injuries sustained by dancers. These differences support the development of dance-style related injury prevention measures and suggest further investigations with the focus being placed on the influence of organizational structures (e.g. number of performances) as well as on the working environments.

  18. The incidence of noncontiguous spinal fractures and other traumatic injuries associated with cervical spine fractures: a 10-year experience at an academic medical center.

    PubMed

    Miller, Christopher P; Brubacher, Jacob W; Biswas, Debdut; Lawrence, Brandon D; Whang, Peter G; Grauer, Jonathan N

    2011-09-01

    Retrospective medical record review. The purpose of this study was to describe the incidence of other injuries that commonly occur in conjunction with cervical spine fractures and dislocations. Cervical spine fractures are often associated with other significant traumatic conditions, which may also require prompt diagnosis and management. However, the relative incidences of the injuries that occur in conjunction with various cervical spine fractures have not been well documented. The radiographic reports of all patients who underwent CT scans of the cervical spine at a single level 1 trauma center over a 10-year period were reviewed. The medical records of individuals with acute, nonpenetrating fractures of the cervical spine were further assessed for any associated traumatic pathology including noncontiguous spine injuries and those affecting other organ systems (i.e., head and neck, intrathoracic, intra-abdominal/pelvic, and nonspinal orthopedic disorders). A total of 13,896 CT scans of the cervical spine were performed during this 10-year period of which 492 revealed acute fractures and/or dislocations. Of these subjects, 60% had sustained at least one additional injury. Overall, 57% were noted to have extraspinal injuries (34% head and neck, 17% intrathoracic, 10% intra-abdominal/pelvic, and 30% nonspinal orthopedic conditions) and noncontiguous spinal trauma was present in 19% of these cases (8% cervical injuries, 8% thoracic, and 6% lumbar). In general, the rates of associated injuries observed with occipital condyle and C7 fractures were significantly higher than those recorded for other cervical segments. For patients with a known history of cervical spine trauma, the frequencies of associated injuries were similar across all levels of the cervical spine with the exception of the injuries to the craniocervical junctions. In practice, this means that injuries to the cervical spine can likely be grouped together when considering other possible associated injuries. Further elucidation of these injury patterns will likely be useful for facilitating the expedient evaluation and proper management of these individuals.

  19. Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

    PubMed

    Terrier, Alexandre; Latypova, Adeliya; Guillemin, Maika; Parvex, Valérie; Guyen, Olivier

    2017-03-01

    Constrained devices, standard implants with large heads, and dual mobility systems have become popular options to manage instability after total hip arthroplasty (THA). Clinical results with these options have shown variable success rates and significant higher rates of aseptic loosening and mechanical failures with constrained implants. Literature suggests potential advantages of dual mobility, however little is known about its biomechanics. We present a comparative biomechanical study of a standard implant, a constrained implant, and a dual mobility system. A finite element analysis was developed to assess and compare these acetabular options with regard to the range of motion (ROM) to impingement, the angle of dislocation, the resistive torque, the volume of polyethylene (PE) with a stress above 80% of the elastic limit, and the interfacial cup/bone stress. Dual mobility implants provided the greatest ROM to impingement and allowed delaying subluxation and dislocation when compared to standard and constrained implants. Dual mobility also demonstrated the lowest resistive torque at subluxation while the constrained implant provided the greatest one. The lowest critical PE volume was observed with the dual mobility implant, and the highest stress at the interfaces was observed with the constrained implant. This study highlights the biomechanical advantages of dual mobility systems over constrained and standard implants, and is supported by the clinical results reported. Therefore, the use of dual mobility systems in situations at risk for instability should be advocated and constrained implants should be restricted to salvage situations.

  20. Posterior spinal osteosynthesis for cervical fracture/dislocation using a flexible multistrand cable system: technical note.

    PubMed

    Huhn, S L; Wolf, A L; Ecklund, J

    1991-12-01

    Cervical instability secondary to fracture/dislocation or traumatic subluxation involving the posterior elements may be treated by a variety of fusion techniques. The rigidity of the stainless steel wires used in posterior cervical fusions often leads to difficulty with insertion, adequate tension, and conformation of the graft construct. This report describes a technique of posterior cervical fusion employing a wire system using flexible stainless steel cables. The wire consists of a flexible, 49-strand, stainless steel cable connected on one end to a short, malleable, blunt leader with the opposite end connected to a small islet. The cable may be used in occipitocervical, atlantoaxial, facet-to-spinous process, and interspinous fusion techniques. The cable loop is secured by using a tension/crimper device that sets the desired tension in the cable. In addition to superior biomechanical strength, the flexibility of the cable allows greater ease of insertion and tension adjustment. In terms of direct operative instrumentation in posterior cervical arthrodesis, involving both the upper and lower cervical spine, the cable system appears to be a safe and efficient alternative to monofilament wires.

  1. Treatment strategy and long-term functional outcome of traumatic elbow dislocation in childhood: a single centre study.

    PubMed

    Nussberger, G; Schädelin, S; Mayr, J; Studer, D; Zimmermann, P

    2018-04-01

    Traumatic elbow dislocation (TED) is the most common injury of large joints in children. There is an ongoing debate on the optimal treatment for TED. We aimed to assess the functional outcome after operative and nonoperative treatment of TED. We analysed the medical records of patients with TED treated at the University Children's Hospital, Basel, between March 2006 and June 2015. Functional outcome was assessed using the Mayo Elbow Performance Score (MEPS) and Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) Sport and Music Module score. These scores were compared between nonoperatively and operatively treated patients. A total of 37 patients (mean age 10.2 years, 5.2 to 15.3) were included. Of these, 21 (56.8%) children had undergone nonoperative treatment, with 16 (43.2%) patients having had operative treatment. After a mean follow-up of 5.6 years (1.2 to 5.9), MEPS and QuickDASH Sport and Music Module scores in the nonoperative group and operative group were similar: MEPS: 97.1 points (SD 4.6) versus 97.2 points (SD 2.6); 95% confidence interval (CI)-2.56 to 2.03); p = 0.53; QuickDASH Sport and Music Module score: 3.9 points (SD 6.1) versus 3.1 points (SD 4.6); 95% CI 2.60 to 4.17; p = 0.94. We noted no significant differences regarding the long-term functional outcome between the subgroup of children treated operatively versus those treated nonoperatively for TED with accompanying fractures of the medial epicondyle and medial condyle. Functional outcome after TED was excellent, independent of the treatment strategy. If clear indications for surgery are absent, a nonoperative approach for TED should be considered. Level III - therapeutic, retrospective, comparative study.

  2. Traumatic corneal flap displacement after laser in situ keratomileusis (LASIK)

    PubMed Central

    Tsai, Tsung-Han; Peng, Kai-Ling; Lin, Chien-Jen

    2017-01-01

    Background Laser in situ keratomileusis (LASIK) is the most common and popular procedure performed for the correction of refractive errors in the last two decades. We report a case of traumatic flap displacement with flap folding which occurred 3 years after LASIK was performed. Previous literature suggests that vision prognosis would be closely related to proper and prompt management of traumatic flap displacement with flap folding 3 years after LASIK. Case presentation A 23-year-old female presented to our hospital who had undergone uneventful LASIK in both eyes 3 years prior. Unfortunately, she had suffered a blunt trauma in her right eye in a car accident. A late onset of corneal flap displacement was found with upper and lower portion of the flap being folded inside the corneal bed. Surgical intervention for debridement with subsequent reposition of corneal flap was performed as soon as possible in the operating room. A bandage contact lens was placed, and topical antibiotic and corticosteroids were given postoperatively. Two days after the operation, the displaced corneal flap was found to be well attached smoothly on the corneal bed without folds. The best-corrected visual acuity was 6/6 with refraction of −0.75 D to 1.0 D ×175° in her right eye 1 month later. Literature review We reviewed a total of 19 published cases of late-onset traumatic flap dislocations or displacements after LASIK with complete data from 2000 to 2014. Conclusion Traumatic displacement of corneal flaps after LASIK may occur after blunt injury with specific direction of force to the flap margin, especially tangential one. According to the previous literature, late-onset traumatic flap displacement may happen at any time after LASIK and be caused by various types of injuries. Fortunately, good visual function could mostly be restored with immediate and proper management. PMID:28458585

  3. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    PubMed

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

    PubMed

    Bonnaire, F; Lein, T; Bula, P

    2011-06-01

    The objective of any surgical care of a trochanteric femoral fracture should be the achievement of a stable osteosynthesis that allows early full weight-bearing mobilisation of the patient, because long-term immobilisation soon becomes a vital threat to the affected patients who are usually elderly with correlating comorbidities. The anatomical references of the proximal femur and the structure of the hip joint contain some specifics that play an essential role in the incurrence of a trochanteric femoral fracture and the planning of the osteosynthesis as well. With reposition and fracture stabilisation particular importance must be attached to the collo-diaphyseal and the antetorsion angle so that they do not interfere with the functional interaction of the hip and knee joint. Uncomplex trochanteric fractures ordinarily stabilise sufficiently after reposition so that even an extramedullary implant can ensure full weight-bearing stability. With evermore distal fracture course and intertrochanteric comminution zone, rotational instability and pivot transfer of the fracture area to lateral and caudal are followed by an increase of the dislocating forces. These kinds of fractures (A2 and A3 according to the AO/ASIF classification) profit from an intramedullary and rotationally stable osteosynthesis. Basically primary total hip arthroplasty is a potential option for surgical care of a trochanteric fracture in elderly patients with relevant coxarthrosis. However this procedure can only be recommended in cases of a stable uncomplex fracture. The more the medial interlocking of the proximal femur is destroyed the more difficult it will be to primarily implant a total hip prosthesis with good offset and without a varus and rotational failure in the fracture zone.The current studies in the main show disadvantages due to increased complications in these patients, so that in cases of an unstable trochanteric fracture a primary osteosynthesis should be performed followed by total hip arthroplasty after fracture consolidation has occurred.

  5. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    PubMed

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  6. Development and psychometric properties of the Carer – Head Injury Neurobehavioral Assessment Scale (C-HINAS) and the Carer – Head Injury Participation Scale (C-HIPS): patient and family determined outcome scales

    PubMed Central

    Deb, Shoumitro; Bryant, Eleanor; Morris, Paul G; Prior, Lindsay; Lewis, Glyn; Haque, Sayeed

    2007-01-01

    Objective Develop and assess the psychometric properties of the Carer – Head Injury Participation Scale (C-HIPS) and its biggest factor the Carer – Head Injury Neurobehavioral Assessment Scale (C-HINAS). Furthermore, the aim was to examine the inter-informant reliability by comparing the self reports of individuals with traumatic brain injury (TBI) with the carer reports on the C-HIPS and the C-HINAS. Method Thirty-two TBI individuals and 27 carers took part in in-depth qualitative interviews exploring the consequences of the TBI. Interview transcripts were analysed and key themes and concepts were used to construct a 49-item and 58-item patient (Patient – Head Injury Participation Scale [P-HIPS]) and carer outcome measure (C-HIPS) respectively, of which 49 were parallel items and nine additional items were used to assess carer burden. Postal versions of the P-HIPS, C-HIPS, Mayo Portland Adaptability Inventory-3 (MPAI-3), and the Glasgow Outcome Scale-Extended (GOSE) were completed by a cohort of 113 TBI individuals and 80 carers. Data from a sub-group of 66 patient/carer pairs were used to compare inter-informant reliability between the P-HIPS and the C-HIPS, and the P-HINAS and the C-HINAS respectively. Results All individual 49 items of the C-HIPS and their total score showed good test-retest reliability (0.95) and internal consistency (0.95). Comparisons with the MPAI-3 and GOSE found a good correlation with the MPAI-3 (0.7) and a moderate negative correlation with the GOSE (−0.6). Factor analysis of these items extracted a 4-factor structure which represented the domains ‘Emotion/Behavior’ (C-HINAS), ‘Independence/Community Living’, ‘Cognition’, and ‘Physical’. The C-HINAS showed good internal consistency (0.92), test-retest reliability (0.93), and concurrent validity with one MPAI subscale (0.7). Assessment of inter-informant reliability revealed good correspondence between the reports of the patients and the carers for both the C-HIPS (0.83) and the C-HINAS (0.82). Conclusion Both the C-HINAS and the C-HIPS show strong psychometric properties. The qualitative methodology employed in the construction stage of the questionnaires provided good evidence of face and content validity. Comparisons between the P-HIPS and the C-HIPS, and the P-HINAS and the C-HINAS indicated high levels of agreement suggesting that in situations where the patient is unable to provide self-reports, information provided by the carer could be used. PMID:19300569

  7. Iliopsoas tendon rupture: a new differential for atraumatic groin pain post-total hip arthroplasty.

    PubMed

    Piggott, Robert Pearse; Doody, Orla; Quinlan, John Francis

    2015-02-26

    Groin pain post-total hip arthroplasty (THA) is of concern for the patient and the surgeon, especially when there is no history of any traumatic event. Obvious concern centres on complications from the prosthesis. The use of multiple imaging modalities allow for accurate diagnosis of groin pain. Atraumatic iliopsoas rupture is rare and has only been reported once before in the setting of THA. We present the case of 53-year old female with atraumatic rupture of the iliopsoas tendon that presented with severe groin pain and limited flexion. We discuss the clinical presentation, radiological features and follow-up of the patient. We also discuss the relevant published literature on the topic. This is a rare phenomenon but should be consider in patients with groin pain post-THA, especially after prosthesis complications have been ruled out. 2015 BMJ Publishing Group Ltd.

  8. [Characteristics in treatment of the hip in patients with Down syndrome].

    PubMed

    Peterlein, C-D; Schiel, M; Timmesfeld, N; Schofer, M D; Eberhardt, O; Wirth, T; Fernandez, F F

    2013-12-01

    The treatment of hip instability in patients with Down syndrome is challenging. We have performed different pelvic osteotomies and corrections at the proximal femur for this indication. This retrospective study was conducted to evaluate the clinical and radiological outcome of each intervention. All in all, 166 patients with Down syndrome were treated at our orthopaedic department in the observation period. Problems related to the hip joint were diagnosed in 63 of those patients. Only patients who underwent surgery were included in this study. The charts and X-rays of these 31 patients were evaluated with respect to the following parameters: incidence of the hip problem, concomitant diseases, temporal progress, kind of operation method and date, duration of stay in the hospital, after-care, follow-on surgery related to complications, AC angle, CE angle, ACM angle, CCD angle, index of migration according to Reimers, classification of Bauer and Kerschbauer and general morphology of the femoral head. The group was compared with an age-matched group of 21 patients with hip dysplasia. Those patients underwent the same sort of operation in the same year. In the Morbus Down group, we performed surgery for preservation of the hip in 49 cases. This included 13 osteotomies according to Chiari, 11 triple osteotomies according to Tönnis, 10 corrections by femoral varus derotation osteotomy, 8 pelvic osteotomies according to Pemberton, 5 pelvic osteotomies according to Salter and 2 open reductions of the hip. With respect to the moment of surgery, we detected three peaks of age. There was no difference in course of disease and quantity of complications between the groups. Satisfactory results concerning clinical and radiological outcome were achieved predominantly by complete redirectional acetabular osteotomies. Half of the patients who were solely treated by femoral varus derotation osteotomy needed follow-on surgery in the form of pelvic osteotomy. Comparison of preoperative and postoperative range of motion of the hip joint between groups detected capsular insufficiency, increased ligamentous laxity and muscular hypotonia in patients with Down syndrome. Comparison of pelvic radiographs demonstrated significant improvement concerning measured angles in both groups. Preoperative values with respect to AC angle and CE angle were demonstrated to be lower in the hip dysplasia group (p < 0.01); whereas values for ACM angle were comparable between groups. Hypermobility and secondary dislocation of the hip joint is a common problem in patients with Down syndrome, which often requires surgical intervention at an early stage. According to our data and clinical results we suggest a complete redirectional acetabular osteotomy in combination with capsular plication for treatment of this challenging condition. Georg Thieme Verlag KG Stuttgart · New York.

  9. Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

    PubMed

    Sedrakyan, Art; Normand, Sharon-Lise T; Dabic, Stefan; Jacobs, Samantha; Graves, Stephen; Marinac-Dabic, Danica

    2011-11-29

    To determine comparative safety and effectiveness of combinations of bearing surfaces of hip implants. Systematic review of clinical trials, observational studies, and registries. Medline, Embase, Cochrane Controlled Trials Register, reference lists of articles, annual reports of major registries, summaries of safety and effectiveness for pre-market application and mandated post-market studies at the United States Food and Drug Administration. Criteria for inclusion were comparative studies in adults reporting information for various combinations of bearings (such as metal on metal and ceramic on ceramic). Data search, abstraction, and analyses were independently performed and confirmed by at least two authors. Qualitative data syntheses were performed. There were 3139 patients and 3404 hips enrolled in 18 comparative studies and over 830 000 operations in national registries. The mean age range in the trials was 42-71, and 26-88% were women. Disease specific functional outcomes and general quality of life scores were no different or they favoured patients receiving metal on polyethylene rather than metal on metal in the trials. While one clinical study reported fewer dislocations associated with metal on metal implants, in the three largest national registries there was evidence of higher rates of implant revision associated with metal on metal implants compared with metal on polyethylene. One trial reported fewer revisions with ceramic on ceramic compared with metal on polyethylene implants, but data from national registries did not support this finding. There is limited evidence regarding comparative effectiveness of various hip implant bearings. Results do not indicate any advantage for metal on metal or ceramic on ceramic implants compared with traditional metal on polyethylene or ceramic on polyethylene bearings.

  10. [Orthopedic management of spina bifida].

    PubMed

    Biedermann, R

    2014-07-01

    Spina bifida is associated with congenital deformities, such as kyphosis, spinal malformations, teratological hip dislocations, clubfeet, vertical talus and also with acquired deformities due to muscle imbalance and impaired biomechanics. The degree of the acquired deformities and the mobility of the patient depend on the level of the spinal lesion. Neurological symptoms are mostly asymmetric and there is an inconsistent correlation between the anatomical level of the lesion and muscle function. Deficits of sensation are usually one to two levels lower than the motor level. An exact neurological diagnosis should not be made before the second or third year of life and an early prognosis about walking ability should be avoided. The level L3 and therefore function of the quadriceps is a functional milestone after which modified independent ambulation with the use of ankle foot orthoses (AFO) and crutches is possible. The basic principle is to support verticalization and gait even when loss of ambulation is later expected. It is also important to support and maintain sitting ability for high lesions, if necessary with correction of the spinal deformity. Findings in gait analysis have shifted the focus of treatment from radiological criteria to functional improvement, thus maintenance of the flexibility of the hip is the main goal of hip surgery. Reduction of the hip often leads to stiffness and has a high redislocation rate. Clubfoot deformities should be treated early and foot arthrodesis and stiffness have to be avoided. Another focus is the prevention of joint contracture by early prophylactic treatment. The purpose of management is to maximize the functional potential of the child. Subjective well-being, absence of pain, mobility and socialization are the main goals. This does not necessarily imply ambulation; nevertheless, verticalization and associated orthotic management is one major objective of the orthopedic management of spina bifida.

  11. A 2- to 7-Year Follow-Up of a Modular Iliac Screw Cup in Major Acetabular Defects: Clinical, Radiographic and Survivorship Analysis With Comparison to the Literature.

    PubMed

    Cadossi, Matteo; Garcia, Flávio Luís; Sambri, Andrea; Andreoli, Isabella; Dallari, Dante; Pignatti, Giovanni

    2017-01-01

    Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. RANDOMIZED PROSPECTIVE STUDY ON TRAUMATIC PATELLAR DISLOCATION: CONSERVATIVE TREATMENT VERSUS RECONSTRUCTION OF THE MEDIAL PATELLOFEMORAL LIGAMENT USING THE PATELLAR TENDON, WITH A MINIMUM OF TWO YEARS OF FOLLOW-UP.

    PubMed

    Bitar, Alexandre Carneiro; D'Elia, Caio Oliveira; Demange, Marco Kawamura; Viegas, Alexandre Christo; Camanho, Gilberto Luis

    2011-01-01

    The aim of this study was to compare the surgical results from reconstruction of the medial patellofemoral ligament (MPFL) with non-operative treatment of primary patellar dislocation. Thirty-nine patients (41 knees) with patellar dislocation were randomized into two groups. One group was treated conservatively (immobilization and physiotherapy) and other was treated surgically with reconstruction of the MPFL, and the results were evaluated with a minimum follow-up of two years. The Kujala questionnaire was applied to assess pain and quality of life, and recurrences were evaluated. Pearson's chi-square test and Fisher's exact test were used in the statistical evaluation. The statistical analysis showed that the mean Kujala score was significantly lower in the conservative group (70.8), compared with the mean value in the surgical group (88.9), with p = 0.001. The surgical group presented a higher percentage of "good/excellent" Kujala score results (71.43%) than in the conservative group (25.0%), with p = 0.003. The conservative group presented a greater number of recurrences (35% of the cases), while in the surgical group there were no reports of recurrences and/or subluxation. Treatment with reconstruction of the medial patellofemoral ligament using the patellar tendon produced better results, based on the analysis of post-treatment recurrences and the better final results from the Kujala questionnaire after a minimum follow-up period of two years.

  13. [Prof. Dr. Michiharu Matsuoka, founder of the Department of Orthopaedic Surgery, Kyoto University, and his achievements. Part 3: books written by prof. Dr. M. Matsuoka].

    PubMed

    Hirotani, Hayato

    2009-03-01

    In addition to articles written by Prof. Dr. M. Matsuoka previously reported in Part 2, books written by him are presented as Part 3 of the articles regarding his academic achievements. He published four text books, including the first textbook of orthopaedic surgery in Japan that was written by a Japanese doctor and a monograph on the x-ray atlas of congenital dislocation of the hip that was written in German and published in Germany. He was also invited to submit articles to three books as co-author. Furthermore, his five educational lectures given to the public were published in two books.

  14. Femoroacetabular Impingement Surgery Is on the Rise-But What Is the Next Step?

    PubMed

    Reiman, Michael P; Thorborg, Kristian; Hölmich, Per

    2016-06-01

    Surgery for femoroacetabular impingement (FAI) has been advocated for correction of cam and pincer hip joint morphology. Surgery for FAI was first pioneered by Myers et al, who surgically treated FAI by open dislocation. Arthroscopy was then introduced in 2005 by Sampson. Arthroscopy has continued to develop since then, with the intent of providing pain relief and improving function in patients with FAI. This Viewpoint discusses the escalating popularity of FAI surgery, the widespread acceptance of this relatively new surgical procedure, and next steps for determination of who benefits from this treatment. J Orthop Sports Phys Ther 2016;46(6):406-408. doi:10.2519/jospt.2016.0605.

  15. Creep of quartz by dislocation and grain boundary processes

    NASA Astrophysics Data System (ADS)

    Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.

    2015-12-01

    Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.

  16. Ehlers–Danlos Syndrome—Hypermobility Type: A Much Neglected Multisystemic Disorder

    PubMed Central

    Gazit, Yael; Jacob, Giris; Grahame, Rodney

    2016-01-01

    Ehlers–Danlos syndrome (EDS)—hypermobility type (HT) is considered to be the most common subtype of EDS and the least severe one; EDS-HT is considered to be identical to the joint hypermobility syndrome and manifests with musculoskeletal complaints, joint instability, and soft tissue overuse injury. Musculoskeletal complaints manifest with joint pain of non-inflammatory origin and/or spinal pain. Joint instability leads to dislocation or subluxation and involves peripheral joints as well as central joints, including the temporomandibular joints, sacroiliac joints, and hip joints. Soft tissue overuse injury may lead to tendonitis and bursitis without joint inflammation in most cases. Ehlers–Danlos syndrome-HT carries a high potential for disability due to recurrent dislocations and subluxations and chronic pain. Throughout the years, extra-articular manifestations have been described, including cardiovascular, autonomic nervous system, gastrointestinal, hematologic, ocular, gynecologic, neurologic, and psychiatric manifestations, emphasizing the multisystemic nature of EDS-HT. Unfortunately, EDS-HT is under-recognized and inadequately managed, leading to neglect of these patients, which may lead to severe disability that almost certainly could have been avoided. In this review article we will describe the known manifestations of the extra-articular systems. PMID:27824552

  17. Use of the Adult Attachment Projective Picture System in the formulation of a case of an adolescent refugee with PTSD.

    PubMed

    Gander, Manuela; Diamond, Diana; Buchheim, Anna; Sevecke, Kathrin

    2018-03-16

    Forced displacements and their psychosocial consequences in adolescent refugees and their families have received increasing attention in recent years. Although supportive family relations play a key role in buffering the impact of traumatization in adolescents, parental ability to provide such is often subject to extreme pressure. Under conditions of forced dislocation and fear, maladaptive interpersonal strategies in the parent-child relationships may develop, contributing to the onset of psychopathology. We explore new aspects of attachment-related issues for the understanding and treatment of adolescent refugees who have experienced multiple traumas in their childhood. We used a multimethod assessment battery including the Adult Attachment Projective Picture System (AAP), the Structured Clinical Interview, the Youth Self Report and the Wechsler Intelligence Scale in an adolescent boy with post-traumatic stress disorder (PTSD). Our subject was an adolescent refugee from the Middle East who demonstrated an unresolved attachment when confronted with loss and fear. His responses on the AAP evoked aspects of insecure-unresolved attachment, including his belief that it is not safe to trust in attachment figures, his limited access to traumatic attachment experiences, his impaired ability to take concrete actions when dealing with threatening attachment situations and the unintentional role-reversal shed new light on our understanding of his traumatic experiences, family functioning and psychopathological symptoms. Our results demonstrate the utility of the AAP in an adolescent refugee with PTSD by expanding our knowledge of a diverse range of experiences across the interpersonal, cognitive, cultural and developmental contexts that formed the basis for an individualized treatment plan.

  18. [A flow diagram for the diagnosis of acute, non-traumatic joint complaints during childhood, retrospectively applied to 115 children].

    PubMed

    ten Cate, R; Lankester, A C; van der Straaten, P J C; van Suijlekom-Smit, L W A; Wit, J M

    2002-06-29

    Acute, non-traumatic joint complaints during childhood can be caused by conditions which require a quick and adequate recognition and treatment as well as by conditions in which an expectant policy can be pursued. On the basis of certain data from the anamnesis, supplemented with findings from the physical examination it is often possible to arrive at a (probable) diagnosis. An algorithm was designed, the differential steps of which were: fever, C-reactive protein titre, involvement of the hip joint, the presence of extra-articular manifestations and the results of a full blood count, erythrocyte sedimentation rate and imaging techniques. When this algorithm was retrospectively applied to the disease data of 115 children with acute, non-traumatic joint complaints, for whom the diagnosis in the status was taken as the gold standard, the correct diagnosis was established for every single child: for 98 (85.2%) by the shortest route and for 17 (14.8%) indirectly. In the case of 4 children, use of this algorithm would have led to unnecessary laboratory investigations and/or treatment. None of the diseases requiring immediate treatment were missed.

  19. What is the clinical course of transient synovitis in children: a systematic review of the literature.

    PubMed

    Asche, Sylvana S; van Rijn, Rogier M; Bessems, Johannes Hjm; Krul, Marjolein; Bierma-Zeinstra, Sita Ma

    2013-11-14

    Transient synovitis of the hip (TS) is considered to be a self-limiting disease in childhood. However, because the etiology is unclear and some cases precede Legg-Perthes' disease, data on follow-up are important. Our aim was to summarize the knowledge on the clinical course of TS in children. The study design was a systematic review and a literature search was conducted in Medline and Embase. Studies describing short and/or long-term follow-up of TS in children were included. Case reports, reviews and studies describing traumatic hip pain were excluded. Study quality was scored and data extraction was performed. The main outcome measures were short-term and long-term clinical course, and recurrence of symptoms. A total of 25 studies were included of which 14 were of high quality. At two-week follow-up, almost all children with TS were symptom free. Those with symptoms persisting for over one month were more prone to develop other hip pathology, such as Legg-Perthes' disease. The recurrence rate of TS ranged from 0-26.3%. At long-term follow-up, 0-10% of the children diagnosed with TS developed Legg-Perthes' disease. Hip pain after intensive physical effort and limited range of motion of the hip at long-term follow-up was reported in 12-28% and in 0-18% of the children, respectively. The majority of the studies indicate that children with TS recover within two weeks; recurrence was seen in 0-26% of the cases. Children with TS should be followed at least six months to increase the likelihood of not missing Legg-Perthes' disease.

  20. Discrete element analysis is a valid method for computing joint contact stress in the hip before and after acetabular fracture.

    PubMed

    Townsend, Kevin C; Thomas-Aitken, Holly D; Rudert, M James; Kern, Andrew M; Willey, Michael C; Anderson, Donald D; Goetz, Jessica E

    2018-01-23

    Evaluation of abnormalities in joint contact stress that develop after inaccurate reduction of an acetabular fracture may provide a potential means for predicting the risk of developing post-traumatic osteoarthritis. Discrete element analysis (DEA) is a computational technique for calculating intra-articular contact stress distributions in a fraction of the time required to obtain the same information using the more commonly employed finite element analysis technique. The goal of this work was to validate the accuracy of DEA-computed contact stress against physical measurements of contact stress made in cadaveric hips using Tekscan sensors. Four static loading tests in a variety of poses from heel-strike to toe-off were performed in two different cadaveric hip specimens with the acetabulum intact and again with an intentionally malreduced posterior wall acetabular fracture. DEA-computed contact stress was compared on a point-by-point basis to stress measured from the physical experiments. There was good agreement between computed and measured contact stress over the entire contact area (correlation coefficients ranged from 0.88 to 0.99). DEA-computed peak contact stress was within an average of 0.5 MPa (range 0.2-0.8 MPa) of the Tekscan peak stress for intact hips, and within an average of 0.6 MPa (range 0-1.6 MPa) for fractured cases. DEA-computed contact areas were within an average of 33% of the Tekscan-measured areas (range: 1.4-60%). These results indicate that the DEA methodology is a valid method for accurately estimating contact stress in both intact and fractured hips. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A Case of Simultaneous Traumatic Dorsal Dislocation of All Five Metatarsophalangeal Joints Treated Successfully With Closed Reduction.

    PubMed

    Bhide, Pushkar P; Anantharaman, Chinnadurai; Mohan, Ganesan; Raju, Karuppanna

    2016-01-01

    Simultaneous dislocation of multiple metatarsophalangeal joints is a rare injury, because of the impediment presented by the anatomy of the lesser metatarsophalangeal joints. To the best of our knowledge, only 1 case of simultaneous dislocation of all 5 metatarsophalangeal joints has been previously reported in peer-reviewed studies. Owing to the same anatomic structures that obstruct relocation, closed reduction has been known to fail in a large proportion of cases. We report a case of simultaneous dorsal dislocation of all 5 metatarsophalangeal joints of the right foot after a motor vehicle accident. The highlight of our case was successful closed reduction after application of the reduction maneuver to all lesser metatarsophalangeal joints simultaneously in the second attempt with the patient under anesthesia. On confirming the stability of the reduction, the foot was immobilized in a short-leg, posterior slab cast for 3 weeks without placing Kirschner wires across the joints. At the 3-month follow-up evaluation, the patient had reacquired their preinjury level of activity with a good range of motion . At the 2-year follow-up evaluation, this range of motion was maintained with no radiologic evidence of arthrosis. We have inferred that the reduction was successful the second time because the maneuver freed the soft tissue structures from the contiguous impingement in the metatarsophalangeal joints by the exact reversal of the mode of injury using simultaneous application of the maneuver to all the lesser metatarsophalangeal joints. We encourage a trial of this modification of the closed reduction method in the emergency setting before proceeding to open reduction, because the results of closed reduction can be biologically rewarding without the risks associated with open surgical dissection. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. High Risk of Readmission in Octogenarians Undergoing Primary Hip Arthroplasty.

    PubMed

    Malkani, Arthur L; Dilworth, Brian; Ong, Kevin; Baykal, Doruk; Lau, Edmund; Mackin, Theresa N; Lee, Gwo-Chin

    2017-12-01

    As life expectancy increases, more elderly patients with end-stage hip arthritis are electing to undergo primary THA. Octogenarians undergoing THA have more comorbidities than younger patients, but this is not reflected in risk adjustment models for bundled care programs. The burden of care associated with THA in octogenarians has not been well characterized, and doing so may help these value-based programs make adjustments so that this vulnerable patient population does not risk losing access under accountable care models. The purpose of this study was to describe care use, comorbidities, and complications among octogenarians undergoing primary THA. Five percent of the Medicare national administrative claims data was queried to identify patients diagnosed with hip osteoarthritis between January 1, 1998, and December 31, 2013. Patients who underwent primary THA were identified and followed longitudinally during the study period using their unique, encrypted Medicare beneficiary identifiers. We compared risk factors and complications between the octogenarian group versus those aged 65 to 69 years. Multivariate Cox regression was used to evaluate the effect of patient/hospital factors on risk of revision, periprosthetic joint infection, dislocation, venous thromboembolism (VTE), and mortality. Patient factors in the model included age, sex, race, region, socioeconomic status, and health status based on Charlson comorbidity score 12 months before replacement surgery. There were 11,960 THAs in the octogenarians in 1998, which increased to 21,620 in 2013, an 81% increase during this study period. Octogenarians were more likely to have a Charlson score of 3 or higher than those patients aged 65 to 69 years (30% versus 17%, odds ratio [OR] 2.07 [1.98-2.20]; p < 0.001), and they were more likely to have coronary artery disease or congestive heart failure (47% versus 29%, OR 2.16 [2.06-2.26]; p < 0.001). The octogenarian group had a greater risk of dislocation (+12%, p = 0.01), VTE (+14%, p < 0.001), and mortality (+150%, p < 0.001) compared with the younger age cohort. A total of 21% of the octogenarians were readmitted after surgery compared with 12% for patients in the younger group (OR=1.64, 95% confidence interval 1.54-1.75; p < 0.001). Because octogenarians are at increased risk of dislocation, VTE, medical complications, and mortality after THA, value-based care models that penalize hospitals for readmissions and complications may inadvertently result in loss of access to care for this group of patients as a result of the financial makeup of these bundled care models. Value-based care models were developed to improve care and decrease healthcare costs but may have unintended consequences in the octogenarian with higher complication and readmission risks. Financial losses may lead to institutions from withdrawing from the Bundled Payments for Care Improvement program. To try to prevent this from happening to this vulnerable patient population, bundled care programs should evolve and be modified to allow for risk stratification in the overall payment formula to account for increased age and comorbid conditions to ensure continued successful participation in the program among all the stakeholders. Level III, therapeutic study.

  3. What MRI Findings Predict Failure 10 Years After Surgery for Femoroacetabular Impingement?

    PubMed

    Hanke, Markus S; Steppacher, Simon D; Anwander, Helen; Werlen, Stefan; Siebenrock, Klaus A; Tannast, Moritz

    2017-04-01

    Magnetic resonance arthrogram (MRA) with radial cuts is presently the best available preoperative imaging study to evaluate chondrolabral lesions in the setting of femoroacetabular impingement (FAI). Existing followup studies for surgical treatment of FAI have evaluated predictors of treatment failure based on preoperative clinical examination, intraoperative findings, and conventional radiography. However, to our knowledge, no study has examined whether any preoperative findings on MRA images might be associated with failure of surgical treatment of FAI in the long term. The purposes of this study were (1) to identify the preoperative MRA findings that are associated with conversion to THA, any progression of osteoarthritis, and/or a Harris hip score of < 80 points after acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through a surgical hip dislocation (SHD) for FAI at a minimum 10-year followup; and (2) identify the age of patients with symptomatic FAI when these secondary degenerative findings were detected on preoperative radial MRAs. We retrospectively studied 121 patients (146 hips) who underwent acetabuloplasty and/or osteochondroplasty of the femoral head-neck junction through SHD for symptomatic anterior FAI between July 2001 and March 2003. We excluded 35 patients (37 hips) with secondary FAI after previous surgery and 11 patients (12 hips) with Legg-Calvé-Perthes disease. All patients underwent preoperative MRA to further specify chondrolabral lesions except in 19 patients (32 hips) including 17 patients (20 hips) who presented with an MRI from an external institution taken with a different protocol, 10 patients with no preoperative MRA because the patients had already been operated on the contralateral side with a similar appearance, and two patients (two hips) refused MRA because of claustrophobia. This resulted in 56 patients (65 hips) with idiopathic FAI and a preoperative MRA. Of those, three patients (three hips) did not have minimal 10-year followup (one patient died; two hips with followup between 5 and 6 years). The remaining patients were evaluated clinically and radiographically at a mean followup of 11 years (range, 10-13 years). Thirteen pathologic radiographic findings on the preoperative MRA were evaluated for an association with the following endpoints using Cox regression analysis: conversion to THA, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80. The age of the patient when each degenerative pattern was found on the preoperative MRA was recorded. The following MRI findings were associated with one or more of our predefined failure endpoints: cartilage damage exceeding 60° of the circumference had a hazard ratio (HR) of 4.6 (95% confidence interval [CI], 3.6-5.6; p = 0.003) compared with a damage of less than 60°, presence of an acetabular rim cyst had a HR of 4.1 (95% CI, 3.1-5.2; p = 0.008) compared with hips without these cysts, and presence of a sabertooth osteophyte had a HR of 3.2 (95% CI, 2.3-4.2; p = 0.013) compared with hips without a sabertooth osteophyte. The degenerative pattern associated with the youngest patient age when detected on preoperative MRA was the sabertooth osteophyte (lower quartile 27 years) followed by cartilage damage exceeding 60° of the circumference (28 years) and the presence of an acetabular rim bone cyst (31 years). Preoperative MRAs with radial cuts reveal important findings that may be associated with future failure of surgical treatment for FAI. Most of these factors are not visible on conventional radiographs or standard hip MRIs. Preoperative MRA evaluation is therefore strongly recommended on a routine basis for patients undergoing these procedures. Findings associated with conversion to arthroplasty, radiographic evidence of any progression of osteoarthritis, and/or a Harris hip score of < 80 points should be incorporated into the decision-making process in patients being evaluated for joint-preserving hip surgery. Level III, therapeutic study.

  4. Computer aided diagnosis and treatment planning for developmental dysplasia of the hip

    NASA Astrophysics Data System (ADS)

    Li, Bin; Lu, Hongbing; Cai, Wenli; Li, Xiang; Meng, Jie; Liang, Zhengrong

    2005-04-01

    The developmental dysplasia of the hip (DDH) is a congenital malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Early diagnosis and treatment is important because failure to diagnose and improper treatment can result in significant morbidity. In this paper, we designed and implemented a computer aided system for the diagnosis and treatment planning of this disease. With the design, the patient received CT (computed tomography) or MRI (magnetic resonance imaging) scan first. A mixture-based PV partial-volume algorithm was applied to perform bone segmentation on CT image, followed by three-dimensional (3D) reconstruction and display of the segmented image, demonstrating the special relationship between the acetabulum and femurs for visual judgment. Several standard procedures, such as Salter procedure, Pemberton procedure and Femoral Shortening osteotomy, were simulated on the screen to rehearse a virtual treatment plan. Quantitative measurement of Acetabular Index (AI) and Femoral Neck Anteversion (FNA) were performed on the 3D image for evaluation of DDH and treatment plans. PC graphics-card GPU architecture was exploited to accelerate the 3D rendering and geometric manipulation. The prototype system was implemented on PC/Windows environment and is currently under clinical trial on patient datasets.

  5. Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study.

    PubMed

    Schmidt-Braekling, Tom; Renner, Lisa; Mintz, Douglas N; Waldstein, Wenzel; Endo, Yoshimi; Boettner, Friedrich

    2017-04-01

    In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Mechanisms of traumatic shoulder injury in elite rugby players.

    PubMed

    Crichton, James; Jones, Doug R; Funk, Lennard

    2012-06-01

    Shoulder injuries in rugby players are common, but the mechanisms of injury are less well understood. This study aims to elucidate common mechanisms of injury and identify the patterns of injury they produce. Twenty-four elite rugby players, referred to the senior author for diagnosis and management of shoulder injuries, were selected. Videos of the injuries were independently reviewed by rugby-medical experts to describe the mechanisms of injury. The mechanisms reported were collated and analysed to determine the level of agreement between reviewers and conclude an overall description of injury mechanisms. The authors identified three mechanisms of shoulder injury from the video analysis. These are the 'Try-Scorer', characterised by hyperflexion of the outstretched arm such as when scoring a try; the 'Tackler', extension of the abducted arm behind the player while tackling; and the 'Direct Impact', a direct blow to the arm or shoulder when held by the side in neutral or slight adduction. The Try Scorer and Tackler mechanisms both involve a levering force on the glenohumeral joint (GHJ). These mechanisms predominantly cause GHJ dislocation, with Bankart, reverse Bankart and superior labrum anterior-posterior tears. The Try-Scorer Mechanism also caused the majority (83%) of rotator cuff tears. The Direct Hit mechanism resulted in GHJ dislocation and labral injury in 37.5% of players and was most likely to cause acromioclavicular joint dislocation and scapula fractures, injuries that were not seen with the other mechanisms. Greater understanding of the mechanisms involved in rugby shoulder injury is useful in understanding the pathological injuries, guiding treatment and rehabilitation and aiding the development of injury-prevention methods.

  7. A new technique for radiographic measurement of acetabular cup orientation.

    PubMed

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  8. Oxidized zirconium on ceramic; Catastrophic coupling.

    PubMed

    Ozden, V E; Saglam, N; Dikmen, G; Tozun, I R

    2017-02-01

    Oxidized zirconium (Oxinium™; Smith & Nephew, Memphis, TN, USA) articulated with polyethylene in total hip arthroplasty (THA) appeared to have the potential to reduce wear dramatically. The thermally oxidized metal zirconium surface is transformed into ceramic-like hard surface that is resistant to abrasion. The exposure of soft zirconium metal under hard coverage surface after the damage of oxidized zirconium femoral head has been described. It occurred following joint dislocation or in situ succeeding disengagement of polyethylene liner. We reported three cases of misuse of Oxinium™ (Smith & Nephew, Memphis, TN, USA) heads. These three cases resulted in catastrophic in situ wear and inevitable failure although there was no advice, indication or recommendation for this use from the manufacturer. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Effects of diabetic peripheral neuropathy on gait in vascular trans-tibial amputees.

    PubMed

    Nakajima, Hiroshi; Yamamoto, Sumiko; Katsuhira, Junji

    2018-07-01

    Patients with diabetes often develop diabetic peripheral neuropathy, which is a distal symmetric polyneuropathy, so foot function on the non-amputated side is expected to affect gait in vascular trans-tibial amputees. However, there is little information on the kinematics and kinetics of gait or the effects of diabetic peripheral neuropathy in vascular trans-tibial amputees. This study aimed to clarify these effects, including the biomechanics of the ankle on the non-amputated side. Participants were 10 vascular trans-tibial amputees with diabetic peripheral neuropathy (group V) and 8 traumatic trans-tibial amputees (group T). Each subject's gait was analyzed at a self-selected speed using a three-dimensional motion analyzer and force plates. Ankle plantarflexion angle, heel elevation angle, and peak and impulse of anterior ground reaction force were smaller on the non-amputated side during pre-swing in group V than in group T. Center of gravity during pre-swing on the non-amputated side was lower in group V than in group T. Hip extension torque during loading response on the prosthetic side was greater in group V than in group T. These findings suggest that the biomechanical function of the ankle on the non-amputated side during pre-swing is poorer in vascular trans-tibial amputees with DPN than in traumatic trans-tibial amputees; the height of the center of gravity could not be maintained during this phase in vascular trans-tibial amputees with diabetic peripheral neuropathy. The hip joint on the prosthetic side compensated for this diminished function at the ankle during loading response. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. USE OF BIOCERAMICS IN FILLING BONE DEFECTS

    PubMed Central

    Garrido, Carlos Antõnio; Sampaio, Tania Clarete Fonseca Vieira Sales

    2015-01-01

    Objective: To present the results from using biological ceramics for filling bone defects resulting from post-traumatic or orthopedic injuries. Methods: Thirty-six patients with bone defects caused by trauma or orthopedic injury were evaluated. Nineteen patients were male (52.8%) and 17 were female (47.2%). Their ages ranged from 19 to 84 years, with a mean of 45.7 years and median of 37 years. Only patients with defects that required at least five grams of biological ceramic were included. Eighteen cases were classified as orthopedic: bone defects were observed in 11 cases of total hip arthroplasty; one case of primary total hip arthroplasty, due to coxarthrosis; five cases of femoral or tibial open wedge osteotomy; and one case of tarsal arthrodesis. There were 18 cases of trauma-related defects; uninfected pseudarthrosis, eight cases; recent fractures of the tibial plateau with compression of the spongy bone, three cases; and exposed fractures treated with external fixators, seven cases. The surgical technique consisted of curetting and debriding the injury until bone suitable for grafting was found. Biological ceramic was then used to fill the defect and some kind of fixation was applied. Results: Among the 36 patients evaluated, it was seen that 35 (97.2%) presented integration of the biological ceramic, while one case of open fracture treated with external fixation had poor integration of the biological ceramic. Conclusion: Treatment of bone defects of orthopedic or post-traumatic etiology using a phosphocalcium ceramic composed of hydroxyapatite was shown to be a practical, effective and safe method. PMID:27022576

  11. Progressive paralyzing sciatica revealing a pelvic pseudoaneurysm a year after hip surgery in a 12yo boy.

    PubMed

    Boulouis, Grégoire; Shotar, Eimad; Dangouloff-Ros, Volodia; Janklevicz, Pierre-Henri; Boddaert, Nathalie; Naggara, Olivier; Brunelle, Francis

    2016-01-01

    Identifying extra spinal causes of a lumbar radiculopathy or polyneuropathy can be a tricky diagnosis challenge, especially in children. Among them, traumatic or iatrogenic pseudoaneurysms of iliac arteries have been seldom reported, in adults' series. The authors report an unusual case of progressive paralyzing left sciatica and lumbar plexopathy in a 12 years old boy, 12 months after a pelvic osteotomy for bilateral hip luxation secondary to osteochondritis dissecans. Spine MRI and pelvic CT angiography revealed a giant internal iliac artery pseudoaneurysm, enclosed in a chronic hematoma. The patient was successfully treated with endovascular coil embolization, and subsequent surgical hematoma evacuation. However, three months after treatment, neurological recovery was incomplete. This case highlights the importance of a rapid and extensive diagnosis work up of all causes of lower limb radiculopathies in children, including pelvic arteries lesions especially after pelvic surgery to avoid therapeutic delays that may jeopardize the chances of neurological recovery. Copyright © 2015 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.

  12. Long-term follow-up of 1217 consecutive short-stem total hip arthroplasty (THA): a retrospective single-center experience.

    PubMed

    Wacha, H; Domsel, G; Herrmann, E

    2018-06-01

    An arthroplasty registry in Germany has been recently established but long-term results for most short-stem innovations are missing. Short-stem hip arthroplasty is usually indicated in young active patients. Our indication was extended to older age groups, femoral neck fractures (FNF), and dysplasia. We evaluated all total hip arthroplasties (THAs) in this population with a collum femoris preserving stem (CFP) performed from 2003 to 2013. A consecutive cohort of 1217 CFP THAs with a mean age of 68.7 years was followed retrospectively for a median of 4.8 years (patient follow-up interquartile range from 3.0 to 6.9 years). A questionnaire, which we used in two previous studies, was answered by 89.15% of patients and included information regarding complaints, grade of satisfaction, re-operations, and dislocation. Of the 1217 patients, 77 had died. Survival of the stem and the cup was assessed using a competing risks approach according to an Aalen-Johanson estimator with revision for septic or aseptic loosening or death as a competing endpoint. Of the patients who answered the questionnaire, 92.5% had no complaints related to the procedures. In all 1217 patients, there were 43 revisions (4.2%) as follows: stem and cup revisions due to aseptic loosening of the stem (n = 10), infections (n = 6), pain (n = 4), or trauma (n = 3); cup revisions due to aseptic loosening (n = 3), dislocation (n = 5), and offset revisions (n = 12). Survivorship was 96% for the stem and 99% for the cup 9 years postoperatively. Statistical analysis confirmed a higher risk for revision in patients with a younger age (p = 0.033), male sex (p = 0.040), dysplasia (p = 0.032), and undersized or extra-large stems for stem revisions (p = 0.001) and female sex (p = 0.036) for cup revisions. FNF (p > 0.20) and age ≥ 80 years (p = 0.114) had no higher risk for loosening of the stem. Our data is also compared with the current literature, especially with the available CFP studies. The survival rate of the CFP stem was as high as 96% after 9 years of followup which compares well-to-previously published long-term survival rates. There is no higher risk for revision in patients 80 years old or older and in cases with femoral neck fractures. The CFP preserves also allowed using standard stems in the rare cases of revision.

  13. Medial versus anterior open reduction for developmental hip dislocation in age-matched patients.

    PubMed

    Hoellwarth, Jason S; Kim, Young-Jo; Millis, Michael B; Kasser, James R; Zurakowski, David; Matheney, Travis H

    2015-01-01

    The difference between medial (MAOR) and anterior (AAOR) approaches for open reduction of developmental hip dysplasia in terms of risk for avascular necrosis (AVN) and need for further corrective surgery (FCS, femoral and/or acetabular osteotomy) is unclear. This study compared age-matched cohorts undergoing either MAOR or AAOR in terms of these 2 primary outcomes. Prognostic impact of presence of ossific nucleus at time of open reduction was also investigated. Institutional review board approval was obtained. Nineteen hips (14 patients) managed by MAOR were matched with 19 hips (18 patients) managed by AAOR based on age at operation (mean 6.0; range, 1.4 to 14.9 mo). Patients with neuromuscular conditions and known connective tissue disorders were excluded. Primary outcomes assessed at minimum 2 years' follow-up included radiographic evidence of AVN (Kalamchi and MacEwen) or requiring FCS. MAOR and AAOR cohorts were similar regarding age at open reduction, sex, laterality, and follow-up duration. One hip in each group had AVN before open reduction thus were excluded from AVN analysis. At minimum 2 years postoperatively (mean 6.2; range, 1.8 to 11.7 y), 4/18 (22%) MAOR and 5/18 (28%) AAOR met the same criteria for AVN (P=1.0). No predictors of AVN could be identified by regression analysis. Presence of an ossific nucleus preoperatively was not a protective factor from AVN (P=0.27). FCS was required in 4/19 (21%) MAOR and 7/19 (37%) AAOR hips (P=0.48). However, 7/12 (54%) hips failing closed reduction required FCS compared with 4/26 (16%) hips without prior failed closed reduction (P=0.024). Cox regression analysis showed that patients who failed closed reduction had an annual risk of requiring FCS approximately 6 times that of patients without a history of failed closed reduction (hazard ratio=6.1; 95% CI, 1.5-24.4; P=0.009), independent of surgical approach (P=0.55) or length of follow-up (P=0.78). In this study of age-matched patients undergoing either MAOR or AAOR, we found no association between surgical approach and risk of AVN or FCS. In addition, we identified no protective benefit of a preoperative ossific nucleus in terms of development of AVN. However, failing closed reduction was associated with a 6-fold increased annual risk of requiring FCS. To the best of our knowledge, this is the first study comparing these 2 surgical techniques in an age-matched manner. It further corroborates previous studies stating that there may be no difference in risk of AVN based on surgical approach or presence of ossific nucleus preoperatively. Level III-retrospective comparative study.

  14. Oral and cranio-maxillofacial surgery in Byzantium.

    PubMed

    Mylonas, Anastassios I; Poulakou-Rebelakou, Eleftheria-Fotini; Androutsos, Georgios I; Seggas, Ioannis; Skouteris, Christos A; Papadopoulou, Evangelia Chr

    2014-03-01

    Byzantine physicians (4th-7th and 8th-12th centuries A.D.), especially those interested in Surgery, developed a number of interesting concepts, views and opinions referring to the field now recognized as Oral and Cranio-maxillofacial Surgery and Pathology. The original texts of Byzantine physicians, written in ancient Greek, and now preserved in the electronic platform Thesaurus Linguae Graecae, at the University of California, Irvine, CA, USA, were investigated in relation to Oral and Cranio-maxillofacial Surgery and Pathology. The most eminent physicians of the Early (4th-7th century A.D.) and Middle (8th-12th century A.D.) Byzantine Period, in particular Oribasius Pergamenus, Aëtius Amidenus, Alexander Trallianus, Theophilus Protospatharius, Paulus Aegineta, Meletius Monachos, and Leo Medicus, in their works deal with topographic and surgical anatomy of the head and neck, and a large list of related topics, including dentoalveolar surgery, oral and cervicofacial infections, trauma of viscerocranium and neurocranium as well as the biomechanics of traumatic brain injuries, temporomandibular joints dysfunction as a consequence of mandibular dislocation, surgical oncology and reconstructive surgery of the head and neck, oral pathology, surgical pathology of salivary glands, therapeutic management of facial nerve dysfunction, preprosthetic surgery, craniofacial surgery, and deformities of the facial skeleton involving anthropologic and craniometric observations. Clinical examination of patients presenting corresponding functional and esthetic problems is considered, using recognizable orthodontic and orthognathic surgical approaches. Finally, specific bandages of the head and neck are described, for treating traumatic injuries of the viscerocranium and neurocranium, diastasis of the cranial sutures, dislocations of the mandible (unilateral and bilateral), as well as inflammatory diseases of the parotids and the neck. Byzantine physicians had been particularly interested in various subjects of the mouth, jaws, face, and head and neck in general, in the frame of course of their general surgery practice. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Outcomes After Arthroscopic Bankart Repair in Adolescent Athletes Participating in Collision and Contact Sports

    PubMed Central

    Saper, Michael G.; Milchteim, Charles; Zondervan, Robert L.; Andrews, James R.; Ostrander, Roger V.

    2017-01-01

    Background: Literature on arthroscopic stabilization in adolescent patients participating in collision and contact sports is limited, as most studies include adolescents within a larger sample group comprised primarily of adults. Purpose: To review the outcomes of arthroscopic Bankart repair for anterior shoulder instability in an adolescent population participating in collision and contact sports. Study Design: Case series; Level of evidence, 4. Methods: This retrospective review included 39 shoulders in 37 adolescent (≤19 years) athletes who underwent primary arthroscopic Bankart repair using suture anchors with at least 2-year follow-up. All patients had a history of trauma to their shoulder resulting in an anterior dislocation. Outcome measures included patient satisfaction, the visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Rowe score. Recurrence of dislocation and return to sporting activity were also assessed. Results: The mean age at the time of surgery was 16.9 years (range, 15-19 years), and the mean follow-up was 6.3 years (range, 4.3-10.0 years); 58.6% of patients participated in collision sports. Time to surgery after the initial dislocation episode was 9.2 months (range, 0.5-36.2 months). Four shoulders (10.3%) had dislocation events postoperatively. The majority (78.1%) of patients returned to sports at the same level of competition. Mean VAS was 0.49 ± 1.0, and the mean ASES and Rowe scores were 92.8 ± 12.6 and 85.0 ± 24.2, respectively. Univariate analyses demonstrated that subjective functional outcomes were negatively correlated with recurrence (ASES, P = .005; Rowe, P = .001) and failure to return to sport (ASES, P = .016; Rowe, P = .004). Independent variables shown to have no significant relationship to functional outcomes included age, follow-up, number of preoperative dislocations, time to surgery, sport classification, competition level, tear extent, number of anchors, concurrent Hill-Sachs lesion, and repair of a superior labral anterior-posterior (SLAP) lesion. Conclusion: Arthroscopic Bankart repair is an effective surgical option for traumatic shoulder instability in adolescents participating in collision and contact sports. At a minimum 4-year follow-up, arthroscopic Bankart repair effectively restored stability in 90% of cases; 80% returned to their preinjury level of sport. PMID:28451607

  16. Lower extremity kinematics during walking and elliptical training in individuals with and without traumatic brain injury.

    PubMed

    Buster, Thad; Burnfield, Judith; Taylor, Adam P; Stergiou, Nicholas

    2013-12-01

    Elliptical training may be an option for practicing walking-like activity for individuals with traumatic brain injuries (TBI). Understanding similarities and differences between participants with TBI and neurologically healthy individuals during elliptical trainer use and walking may help guide clinical applications incorporating elliptical trainers. Ten participants with TBI and a comparison group of 10 neurologically healthy participants underwent 2 familiarization sessions and 1 data collection session. Kinematic data were collected as participants walked on a treadmill or on an elliptical trainer. Gait-related measures, including coefficient of multiple correlations (a measure of similarity between ensemble joint movement profiles; coefficient of multiple correlations [CMCs]), critical event joint angles, variability of peak critical event joint angles (standard deviations [SDs]) of peak critical event joint angles, and maximum Lyapunov exponents (a measure of the organization of the variability [LyEs]) were compared between groups and conditions. Coefficient of multiple correlations values comparing the similarity in ensemble motion profiles between the TBI and comparison participants exceeded 0.85 for the hip, knee, and ankle joints. The only critical event joint angle that differed significantly between participants with TBI and comparison participants was the ankle during terminal stance. Variability was higher for the TBI group (6 of 11 comparisons significant) compared with comparison participants. Hip and knee joint movement patterns of both participants with TBI and comparison participants on the elliptical trainer were similar to walking (CMCs ≥ 0.87). Variability was higher during elliptical trainer usage compared with walking (5 of 11 comparisons significant). Hip LyEs were higher during treadmill walking. Ankle LyEs were greater during elliptical trainer usage. Movement patterns of participants with TBI were similar to, but more variable than, those of comparison participants while using both the treadmill and the elliptical trainer. If incorporation of complex movements similar to walking is a goal of rehabilitation, elliptical training is a reasonable alternative to treadmill-based training.Video Abstract available (see Video, Supplemental Digital Content 1, http://links.lww.com/JNPT/A65) for more insights from the authors.

  17. Outcomes associated with early post-traumatic osteoarthritis and other negative health consequences 3-10 years following knee joint injury in youth sport.

    PubMed

    Whittaker, J L; Woodhouse, L J; Nettel-Aguirre, A; Emery, C A

    2015-07-01

    Post-traumatic osteoarthritis (PTOA) commonly affects the knee joint. Although the risk of PTOA substantially increases post-joint injury, there is little research examining PTOA outcomes early in the period between joint injury and disease onset. Improved understanding of this interval would inform secondary prevention strategies aimed at preventing and/or delaying PTOA progression. This study examines the association between sport-related knee injury and outcomes related to development of PTOA, 3-10 years post-injury. This preliminary analysis of the first year of a historical cohort study includes 100 (15-26 years) individuals. Fifty with a sport-related intra-articular knee injury sustained 3-10 years previously and 50 uninjured age, sex and sport matched controls. The primary outcome was the 'Symptoms' sub-scale of the Knee Osteoarthritis and Injury Outcome Score (KOOS). Secondary outcomes included; the remaining KOOS subscales, body mass index (BMI), hip abductor/adductor and knee extensor/flexor strength, estimated aerobic capacity (VO2max) and performance scores on three dynamic balance tests. Descriptive statistics (mean within-pair difference; 95% Confidence interval (CI) and conditional odds ratio (OR, 95% CI; BMI) were used to compare study groups. Injured participants demonstrated poorer KOOS outcomes [symptoms -9.4 (-13.6, -5.2), pain -4.0 (-6.8, -1.2), quality-of-life -8.0 (-11.0, -5.1), daily living -3.0 (-5.0, -1.1) and sport/recreation -6.9 (-9.9, -3.8)], were 3.75 times (95% CI 1.24, 11.3) more likely to be overweight/obese and had lower triple single leg hop scores compared to controls. No significant group differences existed for remaining balance scores, estimated VO2max, hip or knee strength ratios or side-to-side difference in hip abductor/adductor or quadricep/hamstring strength. This study provides preliminary evidence that youth/young adults following sport-related knee injury report more symptoms and poorer function, and are at greater risk of being overweight/obese 3-10 years post-injury compared to matched uninjured controls. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  18. Case Report Reconstruction of Exposed Ilium With Reverse Turnover Latissimus Dorsi Muscle Flap

    PubMed Central

    Hayashida, Kenji; Endo, Yoshie; Kamebuchi, Katsuhiko

    2011-01-01

    Objective: It is difficult to cover a large skin and soft tissue defect with exposure of the ilium. We therefore performed a new reconstruction technique, using a reverse latissimus dorsi muscle flap fed by perforating branches of only the 10th intercostal artery. Methods: A 45-year-old man had a large traumatic defect located on the hip with exposure of the iliac crest. After confirming and preserving perforating branches of the 10th intercostal artery, the latissimus dorsi muscle flap was turned over just proximal to the perforating branch, and a split-thickness skin graft was performed over the flap. Results: The skin graft took place well and there were no circulation problems. Conclusions: This flap covered a larger area on the hip than the musculocutaneous flap. Furthermore, this is easier to perform and is less invasive than a vascularized free flap. Skin and soft tissue defects that expose bones of the lumbar or hip region can be reconstructed with a local flap; however, the deficit is small for this coverage and usually there is little skin and soft tissue to cover the wound defect in the surrounding area. Thus, it is often difficult to deal with large defects. We performed a reconstruction, using a reverse latissimus dorsi flap fed by perforating branches of the 10th intercostal artery for a large skin and soft tissue defect of the hip with exposure of the iliac crest, resulting in a good outcome. This technique is thought to be useful for reconstruction when the ilium is exposed, and we report the case and surgical procedure. PMID:21559059

  19. Large Morel-Lavallée lesion presenting as fungating mass with skin ulceration.

    PubMed

    Ryan, Christine E; Wachtel, Sarah; Leef, George; Ozdalga, Errol

    2016-01-01

    A Morel-Lavallée lesion, a type of soft tissue degloving injury that has also been referred to as a chronic expanding hematoma, is a relatively rare condition that usually develops following traumatic injury. Here, we present a case of a 60-year-old male with a Morel-Lavallée lesion diagnosed over 5 years after a traumatic injury of the hip. He presented with a large fungating mass and overlying skin ulceration, which was highly suspicious for sarcoma. However, lack of other systemic findings and constitutional complaints, as well as negative imaging studies, did not support a diagnosis of malignancy. This information, combined with the history of remote trauma to the affected area, instead led us to suspect the alternative diagnosis of a Morel-Lavallée lesion. The diagnosis was later confirmed by pathology showing a chronic expanding hematoma. To our knowledge, a Morel-Lavallée lesion presenting as a fungating mass has not been previously described.

  20. Analysis of Femoral Components of Cemented Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Singh, Shantanu; Harsha, A. P.

    2016-10-01

    There have been continuous on-going revisions in design of prosthesis in Total Hip Arthroplasty (THA) to improve the endurance of hip replacement. In the present work, Finite Element Analysis was performed on cemented THA with CoCrMo trapezoidal, CoCrMo circular, Ti6Al4V trapezoidal and Ti6Al4V circular stem. It was observed that cross section and material of femoral stem proved to be critical parameters for stress distribution in femoral components, distribution of interfacial stress and micro movements. In the first part of analysis, designs were investigated for micro movements and stress developed, for different stem materials. Later part of the analysis focused on investigations with respect to different stem cross sections. Femoral stem made of Titanium alloy (Ti6Al4V) resulted in larger debonding of stem at cement-stem interface and increased stress within the cement mantle in contrast to chromium alloy (CoCrMo) stem. Thus, CoCrMo proved to be a better choice for cemented THA. Comparison between CoCrMo femoral stem of trapezium and circular cross section showed that trapezoidal stem experiences lesser sliding and debonding at interfaces than circular cross section stem. Also, trapezium cross section generated lower peak stress in femoral stem and cortical femur. In present study, femur head with diameter of 36 mm was considered for the analysis in order to avoid dislocation of the stem. Also, metallic femur head was coupled with cross linked polyethylene liner as it experiences negligible wear compared to conventional polyethylene liner and unlike metallic liner it is non carcinogenic.

  1. Developmental dysplasia of the hip in the newborn: A systematic review

    PubMed Central

    Gulati, Vivek; Eseonu, Kelechi; Sayani, Junaid; Ismail, Nizar; Uzoigwe, Chika; Choudhury, Muhammed Zaki; Gulati, Pooja; Aqil, Adeel; Tibrewal, Saket

    2013-01-01

    Developmental dysplasia of the hip (DDH) denotes a wide spectrum of conditions ranging from subtle acetabular dysplasia to irreducible hip dislocations. Clinical diagnostic tests complement ultrasound imaging in allowing diagnosis, classification and monitoring of this condition. Classification systems relate to the alpha and beta angles in addition to the dynamic coverage index (DCI). Screening programmes for DDH show considerable geographic variation; certain risk factors have been identified which necessitate ultrasound assessment of the newborn. The treatment of DDH has undergone significant evolution, but the current gold standard is still the Pavlik harness. Duration of Pavlik harness treatment has been reported to range from 3 to 9.3 mo. The beta angle, DCI and the superior/lateral femoral head displacement can be assessed via ultrasound to estimate the likelihood of success. Success rates of between 7% and 99% have been reported when using the harness to treat DDH. Avascular necrosis remains the most devastating complication of harness usage with a reported rate of between 0% and 28%. Alternative non-surgical treatment methods used for DDH include devices proposed by LeDamany, Frejka, Lorenz and Ortolani. The Rosen splint and Wagner stocking have also been used for DDH treatment. Surgical treatment for DDH comprises open reduction alongside a combination of femoral or pelvic osteotomies. Femoral osteotomies are carried out in cases of excessive anteversion or valgus deformity of the femoral neck. The two principal pelvic osteotomies most commonly performed are the Salter osteotomy and Pemberton acetabuloplasty. Serious surgical complications include epiphyseal damage, sciatic nerve damage and femoral neck fracture. PMID:23610749

  2. Acetabular fractures in the elderly treated with a primary Burch-Schneider reinforcement ring, autologous bone graft, and a total hip arthroplasty: a prospective study with a 4-year follow-up.

    PubMed

    Enocson, Anders; Blomfeldt, Richard

    2014-06-01

    To investigate the clinical and radiologic outcomes in elderly patients suffering from an acetabular fracture operated with an acute primary acetabular reinforcement ring, autologous bone graft, and a total hip arthroplasty (THA). Prospective cohort study. Tertiary care university hospital. Fifteen elderly patients (7 women) with a mean age of 76 years and a displaced acetabular fracture after a low-energy trauma were included. The fractures involved the anterior column, but no patients with associated both column fractures were included. All the patients were able to walk independently before the fracture occurred. Primary operation with a Burch-Schneider reinforcement ring, autologous bone graft, and a THA. The patients were reviewed at 4, 12, 24, and 48 months after the fracture occurred. The outcome assessments included complications, reoperations, activity of daily living function, functional scores (Harris hip score and short musculoskeletal function assessment), health-related quality of life [EuroQol (EQ-5D) index score], and radiologic evaluation. There were no prosthetic dislocations, periprosthetic fractures, deep infections, or other adverse events. There were no radiologic signs of loosening of the reinforcement ring or the prosthesis components at any of the follow up sessions, and the autologous bone graft was well incorporated in all the patients at the final follow-up. At 48 months, the mean Harris hip score was 88, the mean short musculoskeletal function assessment dysfunction score was 30, the bother score was 25, and the mean EQ-5D index score was 0.65. All the patients were able to walk independently at the final follow-up. Treatment of displaced anterior column, anterior column posterior hemitransverse and transverse acetabular fractures in elderly patients using a primary reinforcement ring, autologous bone graft, and a THA seems to be a safe option with good functional and radiologic outcomes. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  3. Mechanisms of traumatic shoulder injury in elite rugby players

    PubMed Central

    Crichton, James; Jones, Doug R; Funk, Lennard

    2012-01-01

    Background Shoulder injuries in rugby players are common, but the mechanisms of injury are less well understood. This study aims to elucidate common mechanisms of injury and identify the patterns of injury they produce. Materials and methods Twenty-four elite rugby players, referred to the senior author for diagnosis and management of shoulder injuries, were selected. Videos of the injuries were independently reviewed by rugby-medical experts to describe the mechanisms of injury. The mechanisms reported were collated and analysed to determine the level of agreement between reviewers and conclude an overall description of injury mechanisms. Results The authors identified three mechanisms of shoulder injury from the video analysis. These are the ‘Try-Scorer’, characterised by hyperflexion of the outstretched arm such as when scoring a try; the ‘Tackler’, extension of the abducted arm behind the player while tackling; and the ‘Direct Impact’, a direct blow to the arm or shoulder when held by the side in neutral or slight adduction. The Try Scorer and Tackler mechanisms both involve a levering force on the glenohumeral joint (GHJ). These mechanisms predominantly cause GHJ dislocation, with Bankart, reverse Bankart and superior labrum anterior–posterior tears. The Try-Scorer Mechanism also caused the majority (83%) of rotator cuff tears. The Direct Hit mechanism resulted in GHJ dislocation and labral injury in 37.5% of players and was most likely to cause acromioclavicular joint dislocation and scapula fractures, injuries that were not seen with the other mechanisms. Conclusion Greater understanding of the mechanisms involved in rugby shoulder injury is useful in understanding the pathological injuries, guiding treatment and rehabilitation and aiding the development of injury-prevention methods. PMID:22510645

  4. Sublingual ketorolac versus sublingual tramadol for moderate to severe post-traumatic bone pain in children: a double-blind, randomised, controlled trial.

    PubMed

    Neri, Elena; Maestro, Alessandra; Minen, Federico; Montico, Marcella; Ronfani, Luca; Zanon, Davide; Favret, Anna; Messi, Gianni; Barbi, Egidio

    2013-09-01

    To assess the effectiveness of sublingual ketorolac versus sublingual tramadol in reducing the pain associated with fracture or dislocation of extremities in children. A double-blind, randomised, controlled, non-inferiority trial was conducted in the paediatric emergency department of a research institute. One hundred and thirty-one children aged 4-17 years with suspected bone fracture or dislocation were enrolled. Eligible children were randomised to ketorolac (0.5 mg/kg) and placebo, or to tramadol (2 mg/kg) and placebo by sublingual administration, using a double-dummy technique. Pain was assessed by the patients every 20 min, for a maximum period of 2 h, using the McGrath scale for patients up to 6 years of age, and the Visual Analogue Scale for those older than 6 years of age. The mean pain scores fell significantly from eight to four and five in the ketorolac and tramadol groups, respectively, by 100 min (Wilcoxon sign rank test, p<0.001). The mean pain scores for ketorolac were lower than those for tramadol, but these differences were not significant at any time point (Mann-Whitney U Test, p values: 0-20 min: 0.167; 20-40 min: 0.314; 40-60 min: 0.223; 60-80 min: 0.348; 80-100 min: 0.166; 100-120 min: 0.08). The rescue dose of paracetamol-codeine was administered in 2/60 children in the ketorolac group versus 8/65 in the tramadol group (Fisher exact test, p=0.098). There were no statistically significant differences between the two groups in the frequency of adverse effects. Both sublingual ketorolac and tramadol were equally effective for pain management in children with suspected fractures or dislocations.

  5. Interstitial 1q21.1 Microdeletion Is Associated with Severe Skeletal Anomalies, Dysmorphic Face and Moderate Intellectual Disability.

    PubMed

    Gamba, Bruno F; Zechi-Ceide, Roseli M; Kokitsu-Nakata, Nancy M; Vendramini-Pittoli, Siulan; Rosenberg, Carla; Krepischi Santos, Ana C V; Ribeiro-Bicudo, Lucilene; Richieri-Costa, Antonio

    2016-11-01

    We report on a Brazilian patient with a 1.7-Mb interstitial microdeletion in chromosome 1q21.1. The phenotypic characteristics include microcephaly, a peculiar facial gestalt, cleft lip/palate, and multiple skeletal anomalies represented by malformed phalanges, scoliosis, abnormal modeling of vertebral bodies, hip dislocation, abnormal acetabula, feet anomalies, and delayed neuropsychological development. Deletions reported in this region are clinically heterogeneous, ranging from subtle phenotypic manifestations to severe congenital heart defects and/or neurodevelopmental findings. A few genes within the deleted region are associated with congenital anomalies, mainly the RBM8A , DUF1220 , and HYDIN2 paralogs. Our patient presents with a spectrum of unusual malformations of 1q21.1 deletion syndrome not reported up to date.

  6. Interstitial 1q21.1 Microdeletion Is Associated with Severe Skeletal Anomalies, Dysmorphic Face and Moderate Intellectual Disability

    PubMed Central

    Gamba, Bruno F.; Zechi-Ceide, Roseli M.; Kokitsu-Nakata, Nancy M.; Vendramini-Pittoli, Siulan; Rosenberg, Carla; Krepischi Santos, Ana C.V.; Ribeiro-Bicudo, Lucilene; Richieri-Costa, Antonio

    2016-01-01

    We report on a Brazilian patient with a 1.7-Mb interstitial microdeletion in chromosome 1q21.1. The phenotypic characteristics include microcephaly, a peculiar facial gestalt, cleft lip/palate, and multiple skeletal anomalies represented by malformed phalanges, scoliosis, abnormal modeling of vertebral bodies, hip dislocation, abnormal acetabula, feet anomalies, and delayed neuropsychological development. Deletions reported in this region are clinically heterogeneous, ranging from subtle phenotypic manifestations to severe congenital heart defects and/or neurodevelopmental findings. A few genes within the deleted region are associated with congenital anomalies, mainly the RBM8A, DUF1220, and HYDIN2 paralogs. Our patient presents with a spectrum of unusual malformations of 1q21.1 deletion syndrome not reported up to date. PMID:27920638

  7. Occipital Neuralgia in Chiari I Malformation: Two Different Events or Two Different Faces of the Same Event?

    PubMed

    Tondo, Giacomo; De Marchi, Fabiola; Mittino, Daniela; Cantello, Roberto

    2017-11-29

    Occipital neuralgia (ON) is characterized by severe pain in the occipital region due to an irritation of the occipital nerves. Traumatic injuries, mass or vascular compression, and infective and inflammatory processes could cause ON. The dislocation of a nerve/muscle/tendon, as can happen in malformations such as the Chiari I malformation (CIM), also can be responsible. Usually, headaches associated with CIM and ON are distinguishable based on specific features of pain. However, the diagnosis is not easy in some cases, especially if a clear medical history cannot be accurately collected. Determining if the pain is related to ON rather than to CIM is important because the treatments may be different.

  8. Occipital Neuralgia in Chiari I Malformation: Two Different Events or Two Different Faces of the Same Event?

    PubMed Central

    De Marchi, Fabiola; Mittino, Daniela; Cantello, Roberto

    2017-01-01

    Occipital neuralgia (ON) is characterized by severe pain in the occipital region due to an irritation of the occipital nerves. Traumatic injuries, mass or vascular compression, and infective and inflammatory processes could cause ON. The dislocation of a nerve/muscle/tendon, as can happen in malformations such as the Chiari I malformation (CIM), also can be responsible. Usually, headaches associated with CIM and ON are distinguishable based on specific features of pain. However, the diagnosis is not easy in some cases, especially if a clear medical history cannot be accurately collected. Determining if the pain is related to ON rather than to CIM is important because the treatments may be different. PMID:29392103

  9. Early diagnostics of temporomandibular joint structural elements injures caused by traumatic mandibular bone fractures.

    PubMed

    Pohranychna, Kh R; Stasyshyn, A R; Matolych, U D

    2017-06-30

    A rapidly increasing number of mandibular condylar fractures and some complications related to injuries of temporomandibular elements make this study important. Intra-articular disorders lead to secondary pathological findings such as osteoarthritis, deforming osteoarthrosis, and temporomandibular joint ankylosis that limits mouth opening, mastication, swallowing, breathing, and decreased/lost working capacity or disability. Early diagnosis of intra-articular disorders can prevent from long-lasting functional complications caused by temporomandibular joint injuries. This study was performed for the purpose of early detection and investigation of organic pathological changes in the cartilaginous and osseous tissues of the temporomandibular joint caused by traumatic fractures of the mandibular condyle. Twenty patients underwent a general clinical examination, magnetic resonance imaging (MRI), and immune-enzyme testing for biochemical markers of connective tissue injury (pyridinoline and deoxypyridinoline) in urine. Disk dislocation, deformation, adhesion, perforation or squeeze, tension or disruption of ligaments, and injury of articular surfaces are among complications of mandibular fractures that can be revealed on MRI. As regards biochemical findings, we revealed a sharp rise in the levels of pyridinoline and deoxypyridinoline before treatment and a lack of stabilization within 21 days of treatment.

  10. Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?

    PubMed

    Migaud, Henri; Putman, Sophie; Kern, Grégory; Isida, Ronald; Girard, Julien; Ramdane, Nassima; Delaunay, Christian P; Hamadouche, Moussa

    2016-10-01

    Despite widespread use of ceramic-on-ceramic (CoC) in total hip arthroplasty (THA) during the past 10 years, little is known about why revisions are performed in hips with this bearing or the time elapsed before revision. The purposes of this study were: (1) Do the reasons for first revision differ between CoC bearings and other bearing couples? (2) Does the time to revision differ between CoC and other bearing couples? (3) Are there unique reasons for revisions of CoC bearings? All members of the Société Française de Chirurgie Orthopédique et Traumatologique (SoFCOT) who performed ≥ 30 revisions per year were invited to participate in this multicenter, prospective, observational study. Our data represent 12% of the revision procedures performed in France. A total of 2107 first revisions of THA (from January 2010 to December 2011) were done in 2107 patients (1201 females [57%] and 906 males [43%]; median age, 73 years; age range, 17-104 years) at the time of surgery after a median of 11 years (range, 0 day-42 years) after the primary THA. There were 238 of 2107 (11%) CoC, 148 of 2107 (7%) metal-on-metal (MoM), and 1721 of 2017 (82%) metal-on-polyethylene (MoP) bearings. The reasons for reoperation differed according to the bearing component: (1) for the MoP reference bearing (odds ratio [OR]; 95% confidence interval), cup loosening occurred in 698 of 1721 hips (41%), periprosthetic fracture in 220 of 1721 hips (13%), and osteolysis in 213 of 1721 hips (12%); (2) for CoC, cup loosening occurred in 41 of 238 hips (17%) (OR, 0.31 [0.22-0.43; p < 0.001), infection in 39 of 238 hips (16%) (OR, 1.63 [1.12-2.37]; p = 0.01), and dislocation in 23 of 238 hips (10%) (OR, 0.9 [0.57-1.42]; p = 0.9); (3) for MoM, cup loosening occurred in 28 of 148 hips (19%) (OR, 0.34 [0.22-0.52]; p < 0.001), adverse reaction to metallic debris in 26 of 148 hips (18%) (OR, 18.12 [9.84-33.4]; p < 0.001), and infection in 16 of 148 hips (11%) (OR, 1 [0.59-1.73]; p = 0.9). In comparison with MoP, osteolysis was rarely the reason for revision in CoC (four of 238 hips [2%]; OR, 0.12 [0.05-0.33]; p < 0.001), but this bearing was frequently revised because of iliopsoas irritation (18 of 238 hips [8%]; OR, 4.9 [2.7-9]; p < 0.001). The time elapsed before revision differed between bearings: median of 3 years (range, 3 days to 28 years) for CoC and 4 years (range, 14 days to 37 years) for MoM versus a median 13 years (range, 0 day to 42 years) for MoP (p < 0.001). Thirty-seven of the 238 revisions (16%) were directly related to ceramic use (ceramic breakage [n = 23], squeaking [n = 6], impingement [n = 7], incorrect ceramic insert insertion [n = 1]). No factors were identified that contributed to breakage of the 12 bulk ceramic components (eight heads, four inserts, four of 12 Delta ceramic). No factors were associated with squeaking, iliopsoas irritation, or impingement, but component orientation was not assessed. The reasons and time to first revision differed between CoC and other bearings. CoC THAs are revised earlier and are sensitive to mechanical problems such as impingement, squeaking, and ceramic rupture that did not disappear with introduction of Delta ceramics and large-diameter (≥ 36 mm) bearings. CoC was rarely revised for osteolysis, but a high rate of iliopsoas irritation requires further investigation. Level III, therapeutic study.

  11. Bilateral avascular necrosis of the femoral head following asynchronous postictal femoral neck fractures: a case report and review of the literature.

    PubMed

    Venkatadass, K; Avinash, M; Rajasekaran, S

    2018-05-01

    Bilateral avascular necrosis (AVN) following postictal bilateral fracture neck of the femur is a rare occurrence. Here, we report a case of bilateral AVN of the femoral head following an asynchronous bilateral postictal fracture neck of the femur. A 16-year-old autistic boy presented with left hip pain following an episode of seizures and radiographs showed Delbet type II fracture neck of the left femur. This was treated by closed reduction and cancellous screw fixation and skeletal traction for 6 weeks. At 3 months, follow-up radiograph showed union of the fracture, but he had developed segmental AVN with collapse of the head. At 8 months, the patient presented with pain in the right hip following another episode of seizures and radiograph of the pelvis showed a fresh Delbet type II fracture neck of the right femur with established AVN of the left femoral head. He underwent closed reduction and cancellous screw fixation of the right hip and implant exit of the left hip. At the 6-month follow-up after this surgery, his radiograph of the pelvis showed AVN with collapse and extrusion of the femoral head on the right side as well. Literature review shows an increased risk of fracture neck of the femur among epileptics. The incidence of AVN is maximum in Delbet type I, followed by Delbet type II and type III in that order. Although there are no clear guidelines on the management of post-traumatic AVN of the femoral head, the majority have reported that most of them will eventually develop arthritis and will require total hip replacement at a later date. Upon extensive literature search, no case report of bilateral fracture neck of the femur with bilateral AVN was found and hence this case was reported.

  12. The role of multislice spiral computed tomography in the diagnosis and management of acute facial trauma in patients with multiple injuries.

    PubMed

    Nemsadze, G; Urushadze, O

    2011-11-01

    Using of mutislice spiral CT as first line examination for the diagnosis of Acute Facial trauma in the setting of Polytrauma reduces both: valuable time and cost of patient treatment. After a brief clinical examination, MDCT was performed depending on the area of injury, using a slice thickness of 0.65 mm. The obtained data were analyzed using 3D, MIP and Standard axial with Bone reconstruction protocols. 64 polytrauma patients were evaluated with both Anterior and Lateral craniography (plain skull X ray: AP and Lateral) and Multi Slice CT. Craniography detected only 18 cases of traumatic injuries of facial bones, but exact range of dislocation and accurate management plan could not be established. In the same 64 cases, Multislice CT revealed localization of all existed fractures, range of fragment dislocation, soft tissue damage and status of Paranasal sinus in 62 cases (96.8%). In two cases MS CT missed the facial fracture, in one case the examination was complicated because of bone thinness and numerous fracture fragments, in another multiple foreign body artifacts complicated the investigation. The study results show that, CT investigation based on our MDCT polytrauma protocol, detects all more or less serious facial bone injuries.

  13. Cartilage Morphological and Histological Findings After Reconstruction of the Glenoid With an Iliac Crest Bone Graft.

    PubMed

    Auffarth, Alexander; Resch, Herbert; Matis, Nicholas; Hudelmaier, Martin; Wirth, Wolfgang; Forstner, Rosemarie; Neureiter, Daniel; Traweger, Andreas; Moroder, Philipp

    2018-04-01

    The J-bone graft is presumably representative of iliac crest bone grafts in general and allows anatomic glenoid reconstruction in cases of bone defects due to recurrent traumatic anterior shoulder dislocations. As a side effect, these grafts have been observed to be covered by some soft, cartilage-like tissue when arthroscopy has been indicated after such procedures. To evaluate the soft tissue covering of J-bone grafts by use of magnetic resonance imaging (MRI) and histological analysis. Case series; Level of evidence, 4. Patients underwent MRI at 1 year after the J-bone graft procedures. Radiological data were digitally processed and evaluated by segmentation of axial images. Independent from the MRI analysis, 2 biopsy specimens of J-bone grafts were harvested for descriptive histological analysis. Segmentation of the images revealed that all grafts were covered by soft tissue. This layer had an average thickness of 0.87 mm compared with 1.96 mm at the adjacent native glenoid. Of the 2 biopsy specimens, one exhibited evident hyaline-like cartilage and the other presented patches of chondrocytes embedded in a glycosaminoglycan-rich extracellular matrix. J-bone grafts are covered by soft tissue that can differentiate into fibrous and potentially hyaline cartilage. This feature may prove beneficial for delaying the onset of dislocation arthropathy of the shoulder.

  14. Injuries in Irish dance.

    PubMed

    Stein, Cynthia J; Tyson, Kesley D; Johnson, Victor M; Popoli, David M; d'Hemecourt, Pierre A; Micheli, Lyle J

    2013-12-01

    Irish dance is growing in popularity and competitiveness; however, very little research has focused specifically on this genre of dance. The purpose of this study was to analyze the types of dance injuries incurred by Irish dancers. A chart review was performed to identify all injuries associated with Irish dance seen in the sports medicine or orthopaedic clinics at the investigators' hospital over an 11-year period. "Injury" was defined as any dance-related pain or disorder that led to evaluation in the clinics. Survey data were also collected from study participants. Ultimately, 255 patients from over 30 different schools of dance were seen with injuries directly related (726 clinic visits) or partially related (199 visits) to Irish dance. Participants ranged in age from 4 to 47, with 95% (243/255) under the age of 19. These 255 patients received 437 diagnoses. Almost 80% of the injuries (348/437) were attributable to overuse, and 20.4% were acute and traumatic injuries (89/437). Ninety-five percent (95.9%) of injuries involved the hip or lower extremity. The most common sites were the foot (33.2%), ankle (22.7%), knee (19.7%), and hip (14.4%). Typical diagnoses were tendon injury (13.3%), apophysitis (11.4%), patellofemoral pain and instability (10.8%), stress injury (10.1%), and muscle injury (7.8%). The majority of traumatic injuries were seen in clinic within 3 weeks, but less than a quarter of overuse injuries were seen that quickly. The most common treatment, prescribed to 84.3% of patients, was physical therapy and home exercises, and the majority of dancers (64.3%) were able to return to full dance activity after injury.

  15. Risk and mortality of traumatic brain injury in stroke patients: two nationwide cohort studies.

    PubMed

    Chou, Yi-Chun; Yeh, Chun-Chieh; Hu, Chaur-Jong; Meng, Nai-Hsin; Chiu, Wen-Ta; Chou, Wan-Hsin; Chen, Ta-Liang; Liao, Chien-Chang

    2014-01-01

    Patients with stroke had higher incidence of falls and hip fractures. However, the risk of traumatic brain injury (TBI) and post-TBI mortality in patients with stroke was not well defined. Our study is to investigate the risk of TBI and post-TBI mortality in patients with stroke. Using reimbursement claims from Taiwan's National Health Insurance Research Database, we conducted a retrospective cohort study of 7622 patients with stroke and 30 488 participants without stroke aged 20 years and older as reference group. Data were collected on newly developed TBI after stroke with 5 to 8 years' follow-up during 2000 to 2008. Another nested cohort study including 7034 hospitalized patients with TBI was also conducted to analyze the contribution of stroke to post-TBI in-hospital mortality. Compared with the nonstroke cohort, the adjusted hazard ratio of TBI risk among patients with stroke was 2.80 (95% confidence interval = 2.58-3.04) during the follow-up period. Patients with stroke had higher mortality after TBI than those without stroke (10.2% vs 3.2%, P < .0001) with an adjusted relative risk (RR) of 1.46 (95% confidence interval = 1.15-1.84). Recurrent stroke (RR = 1.60), hemorrhagic stroke (RR = 1.68), high medical expenditure for stroke (RR = 1.80), epilepsy (RR = 1.79), neurosurgery (RR = 1.94), and hip fracture (RR = 2.11) were all associated with significantly higher post-TBI mortality among patients with stroke. Patients with stroke have an increased risk of TBI and in-hospital mortality after TBI. Various characteristics of stroke severity were all associated with higher post-TBI mortality. Special attention is needed to prevent TBI among these populations.

  16. Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach?

    PubMed

    Song, Xinggui; Ni, Ming; Li, Heng; Li, Xin; Li, Xiang; Fu, Jun; Chen, Jiying

    2018-05-23

    The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone. The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared. The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p < 0.001). The mean abduction was 37.50 (37.50° ± 6.76°) in left THA and 38.59 (38.59° ± 6.84°) in right THA (p = 0.011). In the left side, the cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p < 0.001) and for both anteversion and inclination (p < 0.001). Dislocation occurred in 7.0% (35/498) of cases in left THA and 3.2% (16/498) in right THA. The percentages of patients experiencing dislocation were significantly different between the two sides (p = 0.006). This current study demonstrated that surgeon handedness is likely to be a contributing factor that affects cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.

  17. The effects of a Pilates-based exercise rehabilitation program on functional outcome and fall risk reduction in an aging adult status-post traumatic hip fracture due to a fall.

    PubMed

    Stivala, Adam; Hartley, Greg

    2014-01-01

    Currently, little information describing the relationship of Pilates-based strength and stability exercises with fall risk in the geriatric population exists. The purpose of this report was to examine the impact of a Pilates-based rehabilitation (PBR) program on reducing fall risk in an aging adult status postfall with resulting hip fracture and open reduction and internal fixation. The patient was an 84-year-old woman admitted to a skilled nursing facility (SNF) after a right hip fracture resulting from a fall at home. The patient's relevant medical history included frequent falls due to loss of balance, a previous left hip fracture with resultant arthroplasty, and a stroke roughly 20 years prior. The patient received physical therapy and occupational therapy 6 days per week for 26 days in an SNF. The physical therapy intervention consisted of gait and transfer training, neuromuscular reeducation, and an adjunct of specialized PBR exercises for the following impairments: decreased core strength and awareness and poor dynamic stabilization during functional activities. The patient demonstrated increases in lower extremity strength and active range of motion, ambulation distance and speed, and transfer ability. The patient was able to return home and live with her husband while requiring only incidental assistance with activities of daily living. She was able to independently ambulate around her home with her rolling walker. Her fall risk was also reduced from initial evaluation based on several fall risk assessments, including the Four Square Step Test, the Berg Balance Scale, and the Timed Up and Go. This case illustrates the benefit of integrating PBR exercises into a standard SNF rehabilitation program, which may contribute to decreased fall risk.

  18. Pre-operative function, motivation and duration of symptoms predict sporting participation after total hip replacement.

    PubMed

    Ollivier, M; Frey, S; Parratte, S; Flecher, X; Argenson, J N

    2014-08-01

    There is little in the literature on the level of participation in sports which patients undertake after total hip replacement (THR). Our aims in this study were to determine first, the level of sporting activity, second, the predictive factors for returning to sporting activity, and third, the correlation between participation in sports and satisfaction after THR. We retrospectively identified 815 patients who had undergone THR between 1995 and 2005. All were asked to complete a self-administered questionnaire regarding their sporting activity. A total of 571 patients (71%) met the inclusion criteria and completed the evaluation. At a mean follow-up of 9.8 years (sd 2.9), 366 patients (64%) returned to sporting activity as defined by a University of California at Los Angeles (UCLA) score of > 5. The main reasons that patients had for refraining from sports were fear of dislocation (65; 31.6%), avoiding wear (52; 25.4%), and the recommendation of the surgeon (34; 16.6%). There was a significant relationship between higher post-operative participation in sport in those patients with a higher pre-operative Harris hip score (HHS) (p = 0.0074), motivation to participate in sporting activities (p = 0.00022) and a shorter duration of symptoms (p = 0.0034). Finally, there was a correlation between age (p = 0.00013), UCLA score (p = 0.012) and pre-operative HHS (p = 0.00091) and satisfaction. In conclusion, we found that most patients participate in sporting activity after THR, regardless of the advice of their surgeon, and that there is a correlation between the level of participation and pre-operative function, motivation, duration of symptoms and post-operative satisfaction. ©2014 The British Editorial Society of Bone & Joint Surgery.

  19. Treatment of aneurysmal bone cysts of the pelvis and sacrum.

    PubMed

    Papagelopoulos, P J; Choudhury, S N; Frassica, F J; Bond, J R; Unni, K K; Sim, F H

    2001-11-01

    Aneurysmal bone cysts are benign, non-neoplastic, highly vascular bone lesions. The purpose of this study was to describe the prevalence, the clinical presentation, and the recurrence rate of aneurysmal bone cysts of the pelvis and sacrum and to examine the diagnostic and therapeutic options and prognosis for patients with this condition. Forty consecutive patients with an aneurysmal bone cyst of the pelvis and/or sacrum were treated from 1921 to 1996. Their medical records and radiographic and imaging studies were reviewed, and histological sections from the cysts were examined. Seventeen lesions were iliosacral, sixteen were acetabular, and seven were ischiopubic. Seven involved the hip joint, and two involved the sacroiliac joint. All twelve sacral lesions extended to more than one sacral segment and were associated with neurological signs and symptoms. Destructive acetabular lesions were associated with pathological fracture in five patients and with medial migration of the femoral head, hip subluxation, and hip dislocation in one patient each. The mean duration of follow-up was thirteen years (range, three to fifty-three years). Thirty-five patients who were initially treated for a primary lesion had surgical treatment (twenty-one had excision-curettage and fourteen had intralesional excision); two patients also had adjuvant radiation therapy. Of the thirty-five patients, five (14%) had a local recurrence noted less than eighteen months after the operation. Of five patients initially treated for a recurrent lesion, one had a local recurrence. At the latest follow-up examination, all forty patients were disease-free and twenty-eight (70%) were asymptomatic. There were two deep infections. Aneurysmal bone cysts of the pelvis and sacrum are usually aggressive lesions associated with substantial bone destruction, pathological fractures, and local recurrence. Current management recommendations include preoperative selective arterial embolization, excision-curettage, and bone-grafting.

  20. Optimal acetabular component orientation estimated using edge-loading and impingement risk in patients with metal-on-metal hip resurfacing arthroplasty.

    PubMed

    Mellon, Stephen J; Grammatopoulos, George; Andersen, Michael S; Pandit, Hemant G; Gill, Harinderjit S; Murray, David W

    2015-01-21

    Edge-loading in patients with metal-on-metal resurfaced hips can cause high serum metal ion levels, the development of soft-tissue reactions local to the joint called pseudotumours and ultimately, failure of the implant. Primary edge-loading is where contact between the femoral and acetabular components occurs at the edge/rim of the acetabular component whereas impingement of the femoral neck on the acetabular component's edge causes secondary or contrecoup edge-loading. Although the relationship between the orientation of the acetabular component and primary edge-loading has been identified, the contribution of acetabular component orientation to impingement and secondary edge-loading is less clear. Our aim was to estimate the optimal acetabular component orientation for 16 metal-on-metal hip resurfacing arthroplasty (MoMHRA) subjects with known serum metal ion levels. Data from motion analysis, subject-specific musculoskeletal modelling and Computed Tomography (CT) measurements were used to calculate the dynamic contact patch to rim (CPR) distance and impingement risk for 3416 different acetabular component orientations during gait, sit-to-stand, stair descent and static standing. For each subject, safe zones free from impingement and edge-loading (CPR <10%) were defined and, consequently, an optimal acetabular component orientation was determined (mean inclination 39.7° (SD 6.6°) mean anteversion 14.9° (SD 9.0°)). The results of this study suggest that the optimal acetabular component orientation can be determined from a patient's motion and anatomy. However, 'safe' zones of acetabular component orientation associated with reduced risk of dislocation and pseudotumour are also associated with a reduced risk of edge-loading and impingement. Copyright © 2014 Elsevier Ltd. All rights reserved.

Top