Sample records for traumatic vessel source

  1. [Traumatic rupture of the pericardium--the source of massive haemothorax, a case report].

    PubMed

    Hromádka, P; Skach, J; Cernohorský, S; Krivohlávek, M; Gaalová, R

    2011-05-01

    Extensive traumatic haemothorax is a life-threatening condition that requires the surgeon's resolute approach. Massive bleeding may first lead to hypovoleamic shock, then to haemorrhagic shock. The most common sources are bleeding from the chest wall (intercostal artery), bleeding when the lung parenchyma or major intrathoracic vessels are injured. The case report describes a rare case of massive right-sided haemothorax in pericardial rupture with cardiac herniation in a patient with polytrauma when the source of bleeding was artery pericardium. The report draws attention to the treacherousness of the diagnosis in a polytraumatised patient; the report retrospectively evaluates the interpretation of imaging examinations that were carried out

  2. 75 FR 63425 - Regulations Implementing the Longshore and Harbor Workers' Compensation Act: Recreational Vessels

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ...) Traumatic injury. If the individual claims compensation for a traumatic injury, the date of injury is the... vessels may be excluded from the definition of ``employee'' when: (1) The individual's date of injury is before February 17, 2009, the injury is covered under a State workers' compensation law, and the...

  3. 20 CFR 701.504 - When does the recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... The following rules apply to determining the date of injury: (1) Traumatic injury. If the individual claims compensation for a traumatic injury, the date of injury is the date the employee suffered harm... recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009 apply? (a) Date of injury...

  4. 20 CFR 701.504 - When does the recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... The following rules apply to determining the date of injury: (1) Traumatic injury. If the individual claims compensation for a traumatic injury, the date of injury is the date the employee suffered harm... recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009 apply? (a) Date of injury...

  5. 20 CFR 701.504 - When does the recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... The following rules apply to determining the date of injury: (1) Traumatic injury. If the individual claims compensation for a traumatic injury, the date of injury is the date the employee suffered harm... recreational vessel exclusion in the American Recovery and Reinvestment Act of 2009 apply? (a) Date of injury...

  6. Vasopressor use following traumatic injury: protocol for a systematic review

    PubMed Central

    Hylands, Mathieu; Toma, Augustin; Beaudoin, Nicolas; Frenette, Anne-Julie; D'Aragon, Frederick; Belley-Côté, Emilie; Hylander, Morten; Lauzier, François; Siemieniuk, Reed Alexander; Charbonney, Emmanuel; Kwong, Joey; Laake, Jon Henrik; Guyatt, Gordon; Vandvik, Per Olav; Rochwerg, Bram; Green, Robert; Ball, Ian; Scales, Damon; Murthy, Srinivas; Rizoli, Sandro; Asfar, Pierre; Lamontagne, François

    2017-01-01

    Introduction Worldwide, traumatic casualties are projected to exceed 8 million by year 2020. Haemorrhagic shock and brain injury are the leading causes of death following trauma. While intravenous fluids have traditionally been used to support organ perfusion in the setting of haemorrhage, recent investigations have suggested that restricting fluid therapy by tolerating more severe hypotension may improve survival. However, the safety of permissive hypotension remains uncertain, particularly among patients who have suffered a traumatic brain injury. Vasopressors preferentially vasoconstrict blood vessels that supply non-vital organs and capacitance vessels, thereby mobilising the unstressed blood volume. Used as fluid-sparing adjuncts, these drugs can complement resuscitative measures by correcting hypotension without diluting clotting factors or increasing the risk for tissue oedema. Methods and analysis We will identify randomised control trials comparing early resuscitation with vasopressors versus placebo or standard care in adults following traumatic injury. Data sources will include MEDLINE, EMBASE, CENTRAL, clinical trial registries and conference proceedings. Two reviewers will independently determine trial eligibility. For each included trial, we will conduct duplicate independent data extraction and risk of bias assessment. We will assess the overall quality of the data for each individual outcome using the GRADE approach. Ethics and dissemination We will report this review in accordance with the PRISMA statement. We will disseminate our findings at critical care and trauma conferences and through a publication in a peer-reviewed journal. We will also use this systematic review to create clinical guidelines (http://www.magicapp.org), which will be disseminated in a standalone publication. Trial registration number CRD42016033437. PMID:28246141

  7. Traumatic work related fatalities in commercial fishermen in Australia.

    PubMed

    Driscoll, T R; Ansari, G; Harrison, J E; Frommer, M S; Ruck, E A

    1994-09-01

    To describe the types and circumstances of traumatic work related fatalities in Australian commercial fishermen. Work related traumatic fishing fatalities were studied as part of a larger study of all work related traumatic fatalities in Australia from 1982 to 1984. Data on 47 cases were obtained from inspection of coroners' files. The incidence of fatality of 143/100,000 person-years was 18 times higher than the incidence of fatality for the entire workforce, and considerably higher than that of the mining and agricultural workforces. 68% of decedents drowned and 13% died from physical trauma. Rough weather, non-seaworthy vessels, inadequate use of personal flotation devices, and inexperience were associated with many of the fatal incidents. Improved vessel and equipment maintenance, better training of workers, greater use of personal flotation devices, and development of improved clothing and personal flotation devices are recommended.

  8. Vasopressor use following traumatic injury: protocol for a systematic review.

    PubMed

    Hylands, Mathieu; Toma, Augustin; Beaudoin, Nicolas; Frenette, Anne-Julie; D'Aragon, Frederick; Belley-Côté, Emilie; Hylander, Morten; Lauzier, François; Siemieniuk, Reed Alexander; Charbonney, Emmanuel; Kwong, Joey; Laake, Jon Henrik; Guyatt, Gordon; Vandvik, Per Olav; Rochwerg, Bram; Green, Robert; Ball, Ian; Scales, Damon; Murthy, Srinivas; Rizoli, Sandro; Asfar, Pierre; Lamontagne, François

    2017-02-28

    Worldwide, traumatic casualties are projected to exceed 8 million by year 2020. Haemorrhagic shock and brain injury are the leading causes of death following trauma. While intravenous fluids have traditionally been used to support organ perfusion in the setting of haemorrhage, recent investigations have suggested that restricting fluid therapy by tolerating more severe hypotension may improve survival. However, the safety of permissive hypotension remains uncertain, particularly among patients who have suffered a traumatic brain injury. Vasopressors preferentially vasoconstrict blood vessels that supply non-vital organs and capacitance vessels, thereby mobilising the unstressed blood volume. Used as fluid-sparing adjuncts, these drugs can complement resuscitative measures by correcting hypotension without diluting clotting factors or increasing the risk for tissue oedema. We will identify randomised control trials comparing early resuscitation with vasopressors versus placebo or standard care in adults following traumatic injury. Data sources will include MEDLINE, EMBASE, CENTRAL, clinical trial registries and conference proceedings. Two reviewers will independently determine trial eligibility. For each included trial, we will conduct duplicate independent data extraction and risk of bias assessment. We will assess the overall quality of the data for each individual outcome using the GRADE approach. We will report this review in accordance with the PRISMA statement. We will disseminate our findings at critical care and trauma conferences and through a publication in a peer-reviewed journal. We will also use this systematic review to create clinical guidelines (http://www.magicapp.org), which will be disseminated in a standalone publication. CRD42016033437. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Material properties of rat middle cerebral arteries at high strain rates.

    PubMed

    Bell, E David; Converse, Matthew; Mao, Haojie; Unnikrishnan, Ginu; Reifman, Jaques; Monson, Kenneth L

    2018-03-19

    Traumatic brain injury (TBI), resulting from either impact- or non-impact blast-related mechanisms, is a devastating cause of death and disability. The cerebral blood vessels, which provide critical support for brain tissue in both health and disease, are commonly injured in TBI. However, little is known about how vessels respond to traumatic loading, particularly at rates relevant to blast. To better understand vessel responses to trauma, the objective of this project was to characterize the high-rate response of passive cerebral arteries. Rat middle cerebral arteries were isolated and subjected to high-rate deformation in the axial direction. Vessels were perfused at physiological pressures and stretched to failure at strain rates ranging from approximately 100 to 1300 s-1. Although both in vivo stiffness and failure stress increased significantly with strain rate, failure stretch did not depend on rate.

  10. Molecular and Genetic Investigation of Tau in Chronic Traumatic Encephalopthy

    DTIC Science & Technology

    2016-10-01

    Very wide blood vessels, but no gliosis, macrophages, or tangles. 6 Controls Heavy retraction around vessels and high amounts of cell shrinkage...neocortical pyramidal neuron. (B) This neuron contains a mature intracellular tangle. (C) In the white matter, scattered small granular retraction balls

  11. Muscle biopsy

    MedlinePlus

    ... muscle ( myopathic changes ) Tissue death of the muscle (necrosis) Disorders that involve inflammation of the blood vessels and affect muscles ( necrotizing vasculitis ) Traumatic muscle damage ...

  12. Aortic Arch Morphology and Aortic Length in Patients with Dissection, Traumatic, and Aneurysmal Disease.

    PubMed

    Alberta, H B; Takayama, T; Smits, T C; Wendorff, B B; Cambria, R P; Farber, M A; Jordan, W D; Patel, V; Azizzadeh, A; Rovin, J D; Matsumura, J S

    2015-12-01

    To assess aortic arch morphology and aortic length in patients with dissection, traumatic injury, and aneurysm undergoing TEVAR, and to identify characteristics specific to different pathologies. This was a retrospective analysis of the aortic arch morphology and aortic length of dissection, traumatic injury, and aneurysmal patients. Computed tomography imaging was evaluated of 210 patients (49 dissection, 99 traumatic injury, 62 aneurysm) enrolled in three trials that received the conformable GORE TAG thoracic endoprosthesis. The mean age of trauma patients was 43 ± 19.6 years, 57 ± 11.7 years for dissection and 72 ± 9.6 years for aneurysm patients. A standardized protocol was used to measure aortic arch diameter, length, and take-off angle and clockface orientation of branch vessels. Differences in arch anatomy and length were assessed using ANOVA and independent t tests. Of the 210 arches evaluated, 22% had arch vessel common trunk configurations. The aortic diameter and the distance from the left main coronary (LMC) to the left common carotid (LCC) were greater in dissection patients than in trauma or aneurysm patients (p < .001). Aortic diameter in aneurysm patients was greater compared with trauma patients (p < .05). The distances from the branch vessels to the celiac artery (CA) were greater in dissection and aneurysm patients than in trauma patients (p < .001). The take-off angle of the innominate (I), LCCA, and left subclavian (LS) were greater, between 19% and 36%, in trauma patients than in dissection and aneurysm patients (p < .001). Clockface orientation of the arch vessels varies between pathologies. Arch anatomy has significant morphologic differences when comparing aortic pathologies. Describing these differences in a large sample of patients is beneficial for device designs and patient selection. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Pseudoaneurysm of head and neck vessels has been frequently observed in road side bomb blast victims.

    PubMed

    Yousuf, Kamal Muhammad; Khan, Fahad Hanif

    2016-06-01

    Due to recent war situation in neighboring country we have witnessed large number of victims with post-traumatic false (pseudo) aneurysms of head and neck in roadside bomb blast victims in Pakistan. Thus through this observational retrospective study we aim to share our experience of managing these patients. 5 years patients' case records, from June 2008-June 2013, were reviewed from the hospital's records. 14 cases of roadside bomb blast victims, developing false aneurysms of major or minor vessels of head and neck, were studied. We excluded the post-traumatic pseudoaneurysms involving other sites and vessels of the body. We observed the mechanism, the duration of presentation, symptoms/signs, vessels involved, complications and the management done. All 14 cases presented with a localized pulsatile swelling with tenderness in the course of a known artery and with an overlying entry site wound from bomb blast sharp nails. Men were affected more as compared to women. All (14) cases had 2-12 weeks of duration between the injury and presentation. Temporal artery (4) was involved in most cases followed by common carotid artery (3). Open surgery was treatment of choice in 12 (85.7%) of cases; however 2 (14.3%) patients had endovascular intervention to correct the pathology. Post-operatively all patients recovered completely, without any major or minor complications. Surgical intervention remains the management of choice for post-traumatic false aneurysms of head and neck in Pakistan. Despite the benefits of endovascular procedures, improvements must be weighed against the added costs on the patients. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  14. Vascular Neural Network phenotypic transformation after traumatic injury: potential role in long-term sequelae

    PubMed Central

    Badaut, J.; Bix, G.J.

    2014-01-01

    The classical neurovascular unit (NVU), composed primarily of endothelium, astrocytes and neurons, could be expanded to include smooth muscle and perivascular nerves present in both the up and down stream feeding blood vessels (arteries and veins). The extended NVU, which can be defined as the vascular neural network (VNN), may represent a new physiological unit to consider for therapeutic development in stroke, traumatic brain injury, and other brain disorders [1]. This review is focused on traumatic brain injury and resultant post-traumatic changes in cerebral blood-flow, smooth muscle cells, matrix, BBB structures and function and the association of these changes with cognitive outcomes as described in clinical and experimental reports. We suggest that studies characterizing TBI outcomes should increase their focus on changes to the VNN as this may yield meaningful therapeutic targets to resolve post-traumatic dysfunction. PMID:24323723

  15. Computational Model for Hyperfibrinolytic Onset of Acute Traumatic Coagulopathy.

    PubMed

    Wu, Tie Bo; Wu, Sheng; Buoni, Matthew; Orfeo, Thomas; Brummel-Ziedins, Kathleen; Cohen, Mitchell; Petzold, Linda

    2018-04-19

    The onset of acute traumatic coagulopathy in trauma patients exacerbates hemorrhaging and dramatically increases mortality. The disease is characterized by increased localized bleeding, and the mechanism for its onset is not yet known. We propose that the fibrinolytic response, specifically the release of tissue-plasminogen activator (t-PA), within vessels of different sizes leads to a variable susceptibility to local coagulopathy through hyperfibrinolysis which can explain many of the clinical observations in the early stages from severely injured coagulopathic patients. We use a partial differential equation model to examine the consequences of vessel geometry and extent of injury on fibrinolysis profiles. In addition, we simulate the efficacy of tranexamic acid treatment on coagulopathy initiated through endothelial t-PA release, and are able to reproduce the time-sensitive nature of the efficacy of this treatment as observed in clinical studies.

  16. Oxygen Saturation in Closed-Globe Blunt Ocular Trauma

    PubMed Central

    Long, Chongde; Wen, Xin; Gao, Qianying

    2016-01-01

    Purpose. To evaluate the oxygen saturation in retinal blood vessels in patients after closed-globe blunt ocular trauma. Design. Retrospective observational case series. Methods. Retinal oximetry was performed in both eyes of 29 patients with unilateral closed-globe blunt ocular trauma. Arterial oxygen saturation (SaO2), venous oxygen saturation (SvO2), arteriovenous difference in oxygen saturation (SO2), arteriolar diameter, venular diameter, and arteriovenous difference in diameter were measured. Association parameters including age, finger pulse oximetry, systolic pressure, diastolic pressure, and heart rate were analyzed. Results. The mean SaO2 in traumatic eyes (98.1% ± 6.8%) was not significantly different from SaO2 in unaffected ones (95.3% ± 7.2%) (p = 0.136). Mean SvO2 in traumatic eyes (57.1% ± 10.6%) was significantly lower than in unaffected ones (62.3% ± 8.4%) (p = 0.044). The arteriovenous difference in SO2 in traumatic eyes (41.0% ± 11.2%) was significantly larger than in unaffected ones (33.0% ± 6.9%) (p = 0.002). No significant difference was observed between traumatic eyes and unaffected ones in arteriolar (p = 0.249) and venular diameter (p = 0.972) as well as arteriovenous difference in diameter (p = 0.275). Conclusions. Oxygen consumption is increased in eyes after cgBOT, associated with lower SvO2 and enlarged arteriovenous difference in SO2 but not with changes in diameter of retinal vessels. PMID:27699174

  17. Medicolegal diagnostic value and clinical significance of traumatic incomplete tears of the basilar artery.

    PubMed

    Djokic, Vesna; Savic, Slobodan; Atanasijevic, Tatjana

    2003-06-01

    Ruptures of arteries of the vertebrobasilary system are relatively frequent in medicolegal practice, and their origin may be both natural and violent. Tears that affects the whole thickness of the basilar artery cause subarachnoid hemorrhage (SAH), with an often rapid fatal outcome. 1-3 However, in some situations, arterial tears may be incomplete, involving the intima or both the intima and the media, but with preserved adventitia. 1, 4 Although such incomplete tears are not the source of immediate subarachnoid bleeding, their presence may be important from both a medicolegal and a clinical point of view. The aim of this article is to point out the significance of incomplete tears of basilar artery as a possible diagnostic sign of traumatic origin of SAH as well as a certain mechanism of injury, which involves forcible hyperextension and rotational movements of the head. The authors also describe their method of performing longitudinal section of the basilar artery, both at autopsy and for histologic examination, which is convenient for identifying multiple transversal incomplete tears of this blood vessel. The article is based on the analysis of three cases from the autopsy material of the Institute of Forensic Medicine in Belgrade.

  18. Traumatic Arteriovenous Fistula of the Scalp in the Left Temporoparietal Region with Intra- and Extracranial Blood Supply

    PubMed Central

    Zheng, Feng; Augustus Pitts, Herbert; Goldbrunner, Roland; Krischek, Boris

    2016-01-01

    Traumatic AVF of the scalp is a rare abnormal vascular disease. It is defined as a communication between the high flow arterial system and the low flow venous network, which directly connects the arterial feeding vessels of the scalp and the draining veins without an intervening capillary bed. The superficial temporal artery (STA) was involved in 90% of the cases, and 71% of the patients only had one dominant feeding STA. Here, we report the case of a rare large traumatic arteriovenous fistula (AVF) of the scalp that is fed by intra- and extracranial blood supply. The clinical and radiological features are presented, and the possible pathogenesis and surgical technique are discussed. PMID:26885435

  19. Recent Research in Behind-Armor Blunt Trauma and Traumatic Brain Injury

    DTIC Science & Technology

    2014-02-01

    can produce subdural hematomas through tearing of bridging veins. Intracerebral hematomas may also occur when parenchymal blood 6 vessels rupture...coup, or contrecoup, and can be seen as contusions, lacerations, epidural/ subdural hemorrhage, and intracerebral/intraventricular hemorrhage (14

  20. Applying Technology to Enhance Nursing Education in the Psychological Health and Traumatic Brain Injury Needs of Veterans and their Families

    DTIC Science & Technology

    2012-10-01

    mhslearn.csd.disa.mil/ilearn/en/learner/mhs/ portal /civilian_login.jsp Military Health System Portal 6. http://www.dcoe.health.mil/ Defense Centers of...forget. He is in rehab for a traumatic brain injury and is seen today for evaluation of hypertension . During the intake, Andrew casually says, I don t...statement: a. Did you know that hypertension can cause damage to blood vessels that keep organs healthy? b. Are you worried about side effects? There are

  1. Osteoid osteoma of the scaphoid: magnetic resonance imaging vessel sign.

    PubMed

    Kussman, Steven R; Thompson, Michael; Chang, Eric Y

    2015-01-01

    Osteoid osteomas can be a challenging diagnosis, especially in smaller bones and, particularly, in the carpus. Clinical and imaging diagnosis may both be delayed due to other, more common, post-traumatic or inflammatory pathology in the same area. We present a case of a pathologically proven scaphoid osteoid osteoma with a feeding vessel sign on magnetic resonance imaging, previously described in long bones with computed tomography, as a helpful sign for accurate diagnosis in the scaphoid. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Crural artery traumatic injuries: treatment with embolization.

    PubMed

    Lopera, Jorge E; Suri, Rajeev; Cura, Marco; Kroma, Ghazwan; El-Merhi, Fadi

    2008-01-01

    The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulas (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.

  3. Crural Artery Traumatic Injuries: Treatment with Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E., E-mail: Lopera@uthscssa.edu; Suri, Rajeev; Cura, Marco

    The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulasmore » (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.« less

  4. A neurovascular perspective for long-term changes after brain trauma.

    PubMed

    Pop, V; Badaut, J

    2011-12-01

    Traumatic brain injury (TBI) affects all age groups in a population and is an injury generating scientific interest not only as an acute event, but also as a complex brain disease with several underlying neurobehavioral and neuropathological characteristics. We review early and long-term alterations after juvenile and adult TBI with a focus on changes in the neurovascular unit (NVU), including neuronal interactions with glia and blood vessels at the blood-brain barrier (BBB). Post-traumatic changes in cerebral blood-flow, BBB structures and function, as well as mechanistic pathways associated with brain aging and neurodegeneration are presented from clinical and experimental reports. Based on the literature, increased attention on BBB changes should be integrated in studies characterizing TBI outcome and may provide a meaningful therapeutic target to resolve detrimental post-traumatic dysfunction.

  5. Automated Decision-Support Technologies for Prehospital Care of Trauma Casualties

    DTIC Science & Technology

    2010-04-01

    insensitive to prehospital major traumatic pathology . Second, there are numerous potential sources of decision-support failure, and it is not possible...been speculated to be insensitive to prehospital major traumatic pathology . Second, there are numerous potential sources of decision-support failure...the soldiers, and the diagnostic value of prehospital vital signs for major traumatic pathologies has often been questioned [4-8]. Indeed, our

  6. Vessel formation is induced prior to the appearance of cartilage in BMP-2-mediated heterotopic ossification

    USDA-ARS?s Scientific Manuscript database

    Heterotopic ossification (HO), or endochondral bone formation at nonskeletal sites, often results from traumatic injury and can lead to devastating consequences. Alternatively, the ability to harness this phenomenon would greatly enhance current orthopedic tools for treating segmental bone defects. ...

  7. Combined direct and indirect traumatic carotid-cavernous fistula (CCF): Case report and review of the literature.

    PubMed

    Abecassis, Isaac Josh; Morton, Ryan P; Kim, Louis J; Ghodke, Basavaraj V; Levitt, Michael R

    2017-10-01

    Within the current Barrow classification system, there are no categorical descriptions or reports in the literature of cavernous carotid fistulas (CCFs) with both a direct component (type A) and separate indirect contribution (type B, C, or D). We report the first definitive case of a combined simultaneous traumatic direct and indirect CCF, and review the literature on the similar existing entity of traumatic indirect CCFs presenting delayed and subsequent to the treatment of traumatic, direct CCFs. We report a case of simultaneous direct type A CCF with a traumatic indirect CCF component and a review of the relevant literature. An 18year-old female presented after a motor vehicle collision. A diagnostic cerebral angiogram confirmed the diagnosis of CCF, with contribution both directly from the ICA and indirectly via branches of the ECA. The direct component of the CCF was first treated in 3 stages via both transarterial and transvenous coil embolization, followed by a final 4th stage of parent vessel sacrifice in order to treat the residual direct component, with transarterial embolization to treat residual indirect CCF activity. To our knowledge, this is the first report of a traumatic CCF with simultaneous direct (type A) and indirect via the ECA (type C) contributions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Combined pancreaticoduodenal injury after blunt trauma--case report].

    PubMed

    Kaczmarek, Bartosz; Borowiecki, Andrzej; Miernik, Maciej; Wojciechowski, Grzegorz; Ostrowski, Marek

    2002-01-01

    The paper presents a patient with a traumatic combined injury of pancreas, duodenum and peripancreatic vessels successfully treated by performing duodenopancreatectomy with splenectomy. Severe complications developed in postoperative period: postoperative haemorrhage, intra-abdominal abscesses, biliary and intestinal fistula. The diagnostics and operative treatment of such injury were discussed.

  9. Endovascular Management of Extra-cranial Supra-aortic Vascular Injuries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almazedi, Bahir, E-mail: b.almazedi@doctors.org.uk; Lyall, Harpreet; Bhatnagar, Priya

    Supra-aortic vessel injuries are uncommon but can be life-threatening and surgically challenging. Trauma to these vessels may be blunt or penetrating, including iatrogenic trauma following the insertion of central venous lines, which may be preventable. Recent advances in technology have resulted in endovascular therapy becoming a common first-line treatment, and interventional radiologists now play a major role in the management of these vascular injuries. We review the literature on the endovascular management of these types of injuries and describe a spectrum of case-based extra-cranial supra-aortic vascular injuries managed at our institution and the range of imaging appearances, including active contrast extravasation,more » traumatic vessel occlusion, true aneurysms, pseudoaneurysms, and arteriovenous fistulae.« less

  10. Transplantation of autologous bone marrow-derived mesenchymal stem cells for traumatic brain injury☆

    PubMed Central

    Jiang, Jindou; Bu, Xingyao; Liu, Meng; Cheng, Peixun

    2012-01-01

    Results from the present study demonstrated that transplantation of autologous bone marrow-derived mesenchymal stem cells into the lesion site in rat brain significantly ameliorated brain tissue pathological changes and brain edema, attenuated glial cell proliferation, and increased brain-derived neurotrophic factor expression. In addition, the number of cells double-labeled for 5-bromodeoxyuridine/glial fibrillary acidic protein and cells expressing nestin increased. Finally, blood vessels were newly generated, and the rats exhibited improved motor and cognitive functions. These results suggested that transplantation of autologous bone marrow-derived mesenchymal stem cells promoted brain remodeling and improved neurological functions following traumatic brain injury. PMID:25806058

  11. Impact of plasma viscosity on microcirculatory flow after traumatic haemorrhagic shock: A prospective observational study.

    PubMed

    Naumann, David N; Hazeldine, Jon; Bishop, Jon; Midwinter, Mark J; Harrison, Paul; Nash, Gerard; Hutchings, Sam D

    2018-05-19

    Preclinical studies report that higher plasma viscosity improves microcirculatory flow after haemorrhagic shock and resuscitation, but no clinical study has tested this hypothesis. We investigated the relationship between plasma viscosity and sublingual microcirculatory flow in patients during resuscitation for traumatic haemorrhagic shock (THS). Sublingual video-microscopy was performed for 20 trauma patients with THS as soon as feasible in hospital, and then at 24 h and 48 h. Values were obtained for total vessel density, perfused vessel density, proportion of perfused vessels, microcirculatory flow index (MFI), microcirculatory heterogeneity index (MHI), and Point of Care Microcirculation (POEM) scores. Plasma viscosity was measured using a Wells-Brookfield cone and plate micro-viscometer. Logistic regression analyses examined relationships between microcirculatory parameters and plasma viscosity, adjusting for covariates (systolic blood pressure, heart rate, haematocrit, rate and volume of fluids, and rate of noradrenaline). Higher plasma viscosity was not associated with improved microcirculatory parameters. Instead, there were weakly significant associations between higher plasma viscosity and lower (poorer) MFI (p = 0.040), higher (worse) MHI (p = 0.033), and lower (worse) POEM scores (p = 0.039). The current study did not confirm the hypothesis that higher plasma viscosity improves microcirculatory flow dynamics in patients with THS. Further clinical investigations are warranted to determine whether viscosity is a physical parameter of importance during resuscitation of these patients.

  12. Anatomy and development of the meninges: implications for subdural collections and CSF circulation.

    PubMed

    Mack, Julie; Squier, Waney; Eastman, James T

    2009-03-01

    The dura is traditionally viewed as a supportive fibrous covering of the brain containing the dural venous sinuses but otherwise devoid of vessels and lacking any specific function. However, review of the embryology and anatomy reveals the dura to be a complex, vascularized and innervated structure, not a simple fibrous covering. The dura contains an inner vascular plexus that is larger in the infant than in the adult, and this plexus likely plays a role in CSF absorption. This role could be particularly important in the infant whose arachnoid granulations are not completely developed. Although subdural hemorrhage is frequently traumatic, there are nontraumatic conditions associated with subdural hemorrhage, and the inner dural plexus is a likely source of bleeding in these nontraumatic circumstances. This review outlines the development and age-specific vascularity of the dura and offers an alternative perspective on the role of the dura in homeostasis of the central nervous system.

  13. [Repairing of soft tissue defect in leg by free vascularized thoracoumbilical flap with reversed flow].

    PubMed

    Xu, Y Q; Li, Z Y; Li, J

    2000-11-01

    To investigate the clinical effect of free vascularized thoracoumbilical flap with reversal flow in repairing the soft tissue defect in leg with tibia exposure. Forty-four casting mould specimens of leg arteries were studied firstly. Then 25 cases with soft tissue defect and tibia exposure in the proximal-middle segment of leg were adopted in this study. Among them, 18 cases had long distance thrombosis of the anterior tibial vessels or posterior tibial vessels due to traumatic lesion. The maximal size of defect was 28 cm x 11 cm and the minimal size of defect was 11 cm x 9 cm. In operation, the thoracoumbilical flap which was based on the inferior epigastric vessels was anastomosed to the distal end of the anterior tibial vessels or posterior tibial vessels. Anterior tibial artery, posterior tibial artery and fibular artery had rich communication branches in foot and ankle. All the flaps survived, the color and cosmetic result of them were good. The free vascularized thoracoumbilical flap with reversed flow is practical in repairing the soft tissue defect of leg with tibia exposure. Either the anterior tibial vessels or the posterior tibial vessels is normal, and the distal end of injured blood vessels is available, this technique can be adopted.

  14. Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal.

    PubMed

    Kaemmerer, Nadine; Brand, Michael; Hammon, Matthias; May, Matthias; Wuest, Wolfgang; Krauss, Bernhard; Uder, Michael; Lell, Michael M

    2016-10-01

    Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.

  15. [Role of multislice computed tomography in the diagnosis of acute rupture of the thoracic aorta and hepatic artery in a patient with severe concomitant injury].

    PubMed

    Muslimov, R Sh; Sharifullin, F A; Chernaia, N R; Novruzbekov, M S; Kokov, L S

    2015-01-01

    Acute traumatic aortic rupture is associated with extremely high mortality rates and requires emergency diagnosis and treatment. This clinical example shows the role of multislice spiral computed tomography in the emergency diagnosis of rupture of two large arterial vessels in severe concomitant injury. It presents the benefits of this rapid and noninvasive imaging technique, an algorithm of the study and the semiotics of injuries in patients with suspected traumatic aortic rupture. The paper also shows the importance of this method in defining treatment policy and then in the assessment of the results of the performed correction.

  16. 40 CFR Table 4 to Subpart U of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Group 1 Storage Vessels at New Sources... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 4 Table 4 to Subpart U of Part 63—Group 1 Storage Vessels at New Sources Vessel...

  17. 77 FR 40007 - Takes of Marine Mammals Incidental to Specified Activities; Taking Marine Mammals Incidental to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-06

    ... shots; this means that one vessel discharges airguns when the other vessel is recharging. Outside the... and one mini source vessel) would be used during the proposed survey. The sources would be arrays of... [mu]Pa (rms). The mini source vessel would contain one array with eight 40 in\\3\\ airguns for a total...

  18. 40 CFR Table 4 to Subpart U of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Group 1 Storage Vessels at New Sources... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 4 Table 4 to Subpart U of Part 63—Group 1 Storage Vessels at New Sources Vessel...

  19. 40 CFR Table 4 to Subpart U of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Group 1 Storage Vessels at New Sources... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 4 Table 4 to Subpart U of Part 63—Group 1 Storage Vessels at New Sources Vessel...

  20. 40 CFR Table 4 to Subpart U of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Group 1 Storage Vessels at New Sources... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 4 Table 4 to Subpart U of Part 63—Group 1 Storage Vessels at New Sources Vessel...

  1. 40 CFR Table 4 to Subpart U of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Group 1 Storage Vessels at New Sources... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 4 Table 4 to Subpart U of Part 63—Group 1 Storage Vessels at New Sources Vessel...

  2. Development and clinical trial of a practical vessel imaging system for vessel punctures in children

    NASA Astrophysics Data System (ADS)

    Cuper, Natasha J.; Verdaasdonk, Rudolf M.; de Roode, Rowland; Septer, Erica

    2008-02-01

    Venipunctures to draw blood for diagnostics can be cumbersome. Multiple puncture attempts are distressing, painful and traumatic, especially for small children. Drawing blood from babies, in particular, is a problem, due to the cutaneous baby fat, tiny veins and, worst case, a pigmented skin. We developed a practical vein viewing system based on IR translumination that, contrary to commercial systems available, has the advantage of: a) low cost, b) easily implemented in routine practice, c) normal and IR image simultaneously available, d) small add-on, e) child friendly IR illuminator and f) efficient IR light coupling. Before introducing the vessel viewer for clinical application in the children's department, parameters were measured in 194 patients (age 0-17 yrs): time to draw blood, number of attempts, skin characteristics, discomfort of patient, and experience of nurse. In this control group, time to draw blood increases significantly with decreasing age of the children. The instant feedback from the nurses has been valuable for the improvements of especially the illumination sources. A clinical trial has been performed in 125 patients (age 0-6 yrs) to prove effectivity of the system in the blood withdrawal procedure. There was a significant decrease from 13% to 2% in failure rate. Also time needed to search for a vein was significantly decreased. A practical and accessible vein viewing system has been developed and is being introduced for clinical application. Although the concept of patient friendliness is already accepted, measurements need to show the effectiveness for particular groups of patients.

  3. Fatal and non-fatal injuries from vessels under air pressure in construction.

    PubMed

    Welch, L S; Weeks, J; Hunting, K L

    1999-02-01

    Using a surveillance system that captures data on construction workers treated in an urban emergency department, we identified a series of injuries caused by vessels and tools under air pressure. We describe those six cases, as well as similar cases found in the Census of Fatal Occupational Injuries; we also review data from the National Surveillance for Traumatic Occupational Fatalities database and data from the Bureau of Labor Statistics. Among the injuries and deaths for which we had good case descriptions, the majority would have been prevented by adherence to existing Occupational Safety and Health Administration standards in the construction industry.

  4. Femoral vessel injuries in modern warfare since Vietnam.

    PubMed

    Pearl, Jonathan P; McNally, Michael P; Perdue, Philip W

    2003-09-01

    The incidence of lower extremity injuries is high in modern warfare; however the mortality rate from these injuries is low. Despite the overall low mortality of lower extremity injuries, many deaths in modern conflicts are due to femoral vessel injury. The modern warfare literature was reviewed. In Somalia, 1 of the 14 reported deaths was due to a laceration of the superficial femoral artery. In the Persian Gulf, three deaths were reported in an Army field hospital, one resulted from uncontrolled hemorrhage from a profunda femoris artery wound and two others resulted from traumatic amputations with consequent major arterial injury. Despite the advances in modern body armor, the groin is left unprotected. A strategy to help minimize U.S. casualties in modern warfare may be a method of field hemostasis specifically designed for femoral vessel injury.

  5. Condensation induced water hammer driven sterilization

    DOEpatents

    Kullberg, Craig M.

    2004-05-11

    A method and apparatus (10) for treating a fluid or materials therein with acoustic energy has a vessel (14) for receiving the fluid with inner walls shaped to focus acoustic energy to a target zone within the vessel. One or more nozzles (26) are directed into the vessel (14) for injecting a condensable vapor, such as steam, into the vessel (14). The system may include a steam source (18) for providing steam as the condensable vapor from an industrial waste heat source. Steam drums (88) are disposed between the steam source (18) and nozzles (26) to equalize and distribute the vapor pressure. A cooling source (30) provides a secondary fluid for maintaining the liquid in the vessel (14) in subcooled conditions. A heating jacket (32) surrounds the vessel (14) to heat the walls of the vessel (14) and prevent biological growth thereon. A pressurizer (33) may operate the system at elevated pressures.

  6. Localized cortical chronic traumatic encephalopathy pathology after single, severe axonal injury in human brain.

    PubMed

    Shively, Sharon B; Edgerton, Sarah L; Iacono, Diego; Purohit, Dushyant P; Qu, Bao-Xi; Haroutunian, Vahram; Davis, Kenneth L; Diaz-Arrastia, Ramon; Perl, Daniel P

    2017-03-01

    Chronic traumatic encephalopathy (CTE) is a neurodegenerative disease associated with repetitive mild impact traumatic brain injury from contact sports. Recently, a consensus panel defined the pathognomonic lesion for CTE as accumulations of abnormally hyperphosphorylated tau (p-tau) in neurons (neurofibrillary tangles), astrocytes and cell processes distributed around small blood vessels at sulcal depths in irregular patterns within the cortex. The pathophysiological mechanism for this lesion is unknown. Moreover, a subset of CTE cases harbors cortical β-amyloid plaques. In this study, we analyzed postmortem brain tissues from five institutionalized patients with schizophrenia and history of surgical leucotomy with subsequent survival of at least another 40 years. Because leucotomy involves severing axons bilaterally in prefrontal cortex, this surgical procedure represents a human model of single traumatic brain injury with severe axonal damage and no external impact. We examined cortical tissues at the leucotomy site and at both prefrontal cortex rostral and frontal cortex caudal to the leucotomy site. For comparison, we analyzed brain tissues at equivalent neuroanatomical sites from non-leucotomized patients with schizophrenia, matched in age and gender. All five leucotomy cases revealed severe white matter damage with dense astrogliosis at the axotomy site and also neurofibrillary tangles and p-tau immunoreactive neurites in the overlying gray matter. Four cases displayed p-tau immunoreactivity in neurons, astrocytes and cell processes encompassing blood vessels at cortical sulcal depths in irregular patterns, similar to CTE. The three cases with apolipoprotein E ε4 haplotype showed scattered β-amyloid plaques in the overlying gray matter, but not the two cases with apolipoprotein E ε3/3 genotype. Brain tissue samples from prefrontal cortex rostral and frontal cortex caudal to the leucotomy site, and all cortical samples from the non-leucotomized patients, showed minimal p-tau and β-amyloid pathology. These findings suggest that chronic axonal damage contributes to the unique pathology of CTE over time.

  7. 40 CFR Table 6 to Subpart G of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Group 1 Storage Vessels at New Sources.... 63, Subpt. G, Table 6 Table 6 to Subpart G of Part 63—Group 1 Storage Vessels at New Sources Vessel capacity(cubic meters) Vapor pressure a (kilopascals) 38 ≤ capacity<151 ≥13.1 151 ≤ capacity ≥0.7 a Maximum...

  8. 40 CFR Table 6 to Subpart G of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Group 1 Storage Vessels at New Sources.... 63, Subpt. G, Table 6 Table 6 to Subpart G of Part 63—Group 1 Storage Vessels at New Sources Vessel capacity(cubic meters) Vapor pressure a (kilopascals) 38 ≤ capacity<151 ≥13.1 151 ≤ capacity ≥0.7 a Maximum...

  9. 40 CFR Table 6 to Subpart G of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Group 1 Storage Vessels at New Sources.... 63, Subpt. G, Table 6 Table 6 to Subpart G of Part 63—Group 1 Storage Vessels at New Sources Vessel capacity(cubic meters) Vapor pressure a (kilopascals) 38 ≤ capacity<151 ≥13.1 151 ≤ capacity ≥0.7 a Maximum...

  10. 40 CFR Table 6 to Subpart G of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Group 1 Storage Vessels at New Sources.... 63, Subpt. G, Table 6 Table 6 to Subpart G of Part 63—Group 1 Storage Vessels at New Sources Vessel capacity(cubic meters) Vapor pressure a (kilopascals) 38 ≤ capacity<151 ≥13.1 151 ≤ capacity ≥0.7 a Maximum...

  11. 40 CFR Table 6 to Subpart G of... - Group 1 Storage Vessels at New Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Group 1 Storage Vessels at New Sources.... 63, Subpt. G, Table 6 Table 6 to Subpart G of Part 63—Group 1 Storage Vessels at New Sources Vessel capacity(cubic meters) Vapor pressure a (kilopascals) 38 ≤capacity<151 ≥13.1 151 ≤capacity ≥0.7 a Maximum...

  12. 40 CFR Table 2 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Receivers at New Sources 2 Table 2 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 2 Table 2 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at New Sources Vessel...

  13. 40 CFR Table 2 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Receivers at New Sources 2 Table 2 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 2 Table 2 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at New Sources Vessel...

  14. 40 CFR Table 2 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Receivers at New Sources 2 Table 2 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 2 Table 2 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at New Sources Vessel...

  15. 40 CFR Table 2 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Receivers at New Sources 2 Table 2 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 2 Table 2 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at New Sources Vessel...

  16. 40 CFR Table 2 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Receivers at New Sources 2 Table 2 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 2 Table 2 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at New Sources Vessel...

  17. Successful repair of injured hepatic veins and inferior vena cava following blunt traumatic injury, by using cardiopulmonary bypass and hypothermic circulatory arrest.

    PubMed

    Kaoutzanis, Christodoulos; Evangelakis, Erotokritos; Kokkinos, Chrysostomos; Kaoutzanis, Gavriel

    2011-01-01

    Traumatic injury to the retrohepatic veins continues to carry high mortality rates. In the last few decades various management strategies have been proposed. However, treatment of such injuries still remains highly variable and technically challenging due to the surgically inaccessible location of these vessels and the consequent difficulty controlling bleeding. We report a successful repair of complete transection of the two main extraparenchymal hepatic veins and laceration of the retrohepatic inferior vena cava using cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA) following blunt abdominal trauma. Immediate CPB with or without HCA can be life-saving and should be considered for patients with complex isolated retrohepatic venous injuries.

  18. 40 CFR Table 3 to Subpart Ppp of... - Group 1 Storage Vessels at Existing and New Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Group 1 Storage Vessels at Existing...—Group 1 Storage Vessels at Existing and New Affected Sources Vessel capacity(cubic meters) Vapor Pressure a (kilopascals) 75 ≤capacity pressure of total...

  19. 40 CFR Table 3 to Subpart Ppp of... - Group 1 Storage Vessels at Existing and New Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Group 1 Storage Vessels at Existing...—Group 1 Storage Vessels at Existing and New Affected Sources Vessel capacity(cubic meters) Vapor Pressure a (kilopascals) 75 ≤ capacity pressure of...

  20. Modeling Cerebral Vascular Injury

    DTIC Science & Technology

    2016-01-01

    vessels to inform the material response of the surrounding brain tissue. 15. SUBJECT TERMS traumatic brain injury, vasculature, injury biomechanics ...Margulies SS. A fiber-reinforced composite model of the viscoelastic behavior of the brainstem in shear. Journal of Biomechanics . 1999;32:865– 870...RH, McDowell K, Vettel J. High rate computational brain injury biomechanics . ARL Ballistic Technology Workshop; 2010 May 24–26; Herndon, VA. Kraft

  1. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5... 46 Shipping 4 2010-10-01 2010-10-01 false Power sources on vessels of more than 19.8 meters (65...

  2. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  3. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  4. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Power sources on vessels of more than 19.8 meters (65... PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.312 Power sources on vessels... generator sets; (b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5...

  5. Corpus callosum vasculature predicts white matter microstructure abnormalities following pediatric mild traumatic brain injury.

    PubMed

    Wendel, Kara M; Lee, Jeong Bin; Affeldt, Bethann; Hamer, Mary; Harahap-Carrillo, Indira S; Pardo, Andrea C; Obenaus, Andre

    2018-05-09

    Emerging data suggest that pediatric traumatic brain injury (TBI) is associated with impaired developmental plasticity and poorer neuropsychological outcomes than adults with similar head injuries. Unlike adult mild TBI (mTBI), the effects of mTBI on white matter (WM) microstructure and vascular supply are not well-understood in the pediatric population. The cerebral vasculature plays an important role providing necessary nutrients and removing waste. To address this critical element, we examined the microstructure of the corpus callosum (CC) following pediatric mTBI using diffusion tensor imaging (DTI), and investigated myelin, oligodendrocytes, and vasculature of WM with immunohistochemistry. We hypothesized that pediatric mTBI leads to abnormal WM microstructure and impacts the vasculature within the CC, and that these alterations to WM vasculature contribute to the long-term altered microstructure. We induced a closed head injury mTBI at postnatal day 14, then at 4, 14, and 60 days post injury (DPI) mice were sacrificed for analysis. We observed persistent changes in apparent diffusion coefficient (ADC) within the ipsilateral CC following mTBI, indicating microstructural changes, but surprisingly changes in myelin and oligodendrocyte densities were minimal. However, vasculature features of the ipsilateral CC such as vessel density, length, and number of junctions were persistently altered following mTBI. Correlative analysis showed a strong inverse relationship between ADC and vessel density at 60 DPI, suggesting increased vessel density following mTBI may restrict WM diffusion characteristics. Our findings suggest that WM vasculature contributes to the long-term microstructural changes within the ipsilateral CC following mTBI.

  6. OCT imaging of acute vascular changes following mild traumatic brain injury in mice (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Chico-Calero, Isabel; Shishkov, Milen; Welt, Jonathan; Blatter, Cedric; Vakoc, Benjamin J.

    2016-03-01

    While most people recover completely from mild traumatic brain injuries (mTBIs) and concussions, a subset develop lasting neurological disorders. Understanding the complex pathophysiology of these injuries is critical to developing improved prognostic and therapeutic approaches. Multiple studies have shown that the structure and perfusion of brain vessels are altered after mTBI. It is possible that these vascular injuries contribute to or trigger neurodegeneration. Intravital microscopy and mouse models of TBI offer a powerful platform to study the vascular component of mTBI. Because optical coherence tomography based angiography is based on perfusion contrast and is not significantly degraded by vessel leakage or blood brain barrier disruption, it is uniquely suited to studies of brain perfusion in the setting of trauma. However, existing TBI imaging models require surgical exposure of the brain at the time of injury which conflates TBI-related vascular changes with those caused by surgery. In this work, we describe a modified cranial window preparation based on a flexible, transparent polyurethane membrane. Impact injuries were delivered directly through this membrane, and imaging was performed immediately after injury without the need for additional surgical procedures. Using this model, we demonstrate that mTBI induces a transient cessation of flow in the capillaries and smaller vessels near the injury point. Reperfusion is observed in all animals within 3 hours of injury. This work describes new insight into the transient vascular changes induced by mTBI, and demonstrates more broadly the utility of the OCT/polyurethane window model platform in preclinical studies of mTBI.

  7. APPARATUS FOR PRODUCING HIGH VELOCITY SHOCK WAVES IN GASES

    DOEpatents

    Scott, F.R.; Josephson, V.

    1960-02-01

    >A device for producing a high-energy ionized gas region comprises an evacuated tapered insulating vessel and a substantially hemispherical insulating cap hermetically affixed to the large end of the vessel, an annular electrode having a diameter equal to and supported in the interior wall of the vessel at the large end and having a conductive portion inside the vessel, a second electrode supported at the small end of the vessel, means connected to the vessel for introducing a selected gas therein, a source of high potential having two poles. means for connecting one pole of the high potential source to the annular electrode, and means for connecting the other pole of the potential source to the second electrode.

  8. Tracking Vessels to Illegal Pollutant Discharges Using Multisource Vessel Information

    NASA Astrophysics Data System (ADS)

    Busler, J.; Wehn, H.; Woodhouse, L.

    2015-04-01

    Illegal discharge of bilge waters is a significant source of oil and other environmental pollutants in Canadian and international waters. Imaging satellites are commonly used to monitor large areas to detect oily discharges from vessels, off-shore platforms and other sources. While remotely sensed imagery provides a snap-shot picture useful for detecting a spill or the presence of vessels in the vicinity, it is difficult to directly associate a vessel to an observed spill unless the vessel is observed while the discharge is occurring. The situation then becomes more challenging with increased vessel traffic as multiple vessels may be associated with a spill event. By combining multiple sources of vessel location data, such as Automated Information Systems (AIS), Long Range Identification and Tracking (LRIT) and SAR-based ship detection, with spill detections and drift models we have created a system that associates detected spill events with vessels in the area using a probabilistic model that intersects vessel tracks and spill drift trajectories in both time and space. Working with the Canadian Space Agency and the Canadian Ice Service's Integrated Satellite Tracking of Pollution (ISTOP) program, we use spills observed in Canadian waters to demonstrate the investigative value of augmenting spill detections with temporally sequenced vessel and spill tracking information.

  9. Concepts and strategies for clinical management of blast-induced traumatic brain injury and posttraumatic stress disorder.

    PubMed

    Chen, Yun; Huang, Wei; Constantini, Shlomi

    2013-01-01

    After exposure of the human body to blast, kinetic energy of the blast shock waves might be transferred into hydraulic energy in the cardiovascular system to cause a rapid physical movement or displacement of blood (a volumetric blood surge). The volumetric blood surge moves through blood vessels from the high-pressure body cavity to the low-pressure cranial cavity, causing damage to tiny cerebral blood vessels and the blood-brain barrier (BBB). Large-scale cerebrovascular insults and BBB damage that occur globally throughout the brain may be the main causes of non-impact, blast-induced brain injuries, including the spectrum of traumatic brain injury (TBI) and posttraumatic stress disorder (PTSD). The volumetric blood surge may be a major contributor not only to blast-induced brain injuries resulting from physical trauma, but may also be the trigger to psychiatric disorders resulting from emotional and psychological trauma. Clinical imaging technologies, which are able to detect tiny cerebrovascular insults, changes in blood flow, and cerebral edema, may help diagnose both TBI and PTSD in the victims exposed to blasts. Potentially, prompt medical treatment aiming at prevention of secondary neuronal damage may slow down or even block the cascade of events that lead to progressive neuronal damage and subsequent long-term neurological and psychiatric impairment.

  10. 40 CFR Table 3 to Subpart Ppp of... - Group 1 Storage Vessels at Existing and New Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Group 1 Storage Vessels at Existing and... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 3 Table 3 to Subpart PPP of Part 63—Group 1 Storage Vessels at Existing and New Affected Sources Vessel capacity(cubic meters) Vapor Pressure a (kilopascals...

  11. 40 CFR Table 3 to Subpart Ppp of... - Group 1 Storage Vessels at Existing and New Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Group 1 Storage Vessels at Existing and... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 3 Table 3 to Subpart PPP of Part 63—Group 1 Storage Vessels at Existing and New Affected Sources Vessel capacity(cubic meters) Vapor Pressure a (kilopascals...

  12. Percutaneous Retrieval of Foreign Bodies Around Vital Vessels Aided with Vascular Intervention: A Technical Note

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xiu-Jun, E-mail: woothingyang2008@126.com; Xing, Guang-Fu, E-mail: xgf8848@126.com

    ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow ofmore » the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.« less

  13. Method and apparatus for converting hydrocarbon fuel into hydrogen gas and carbon dioxide

    DOEpatents

    Clawson, Lawrence G.; Mitchell, William L.; Bentley, Jeffrey M.; Thijssen, Johannes H.J.

    2000-01-01

    An apparatus and a method are disclosed for converting hydrocarbon fuel or an alcohol into hydrogen gas and carbon dioxide. The apparatus includes a first vessel having a partial oxidation reaction zone and a separate steam reforming reaction zone that is distinct from the partial oxidation reaction zone. The first vessel has a first vessel inlet at the partial oxidation reaction zone and a first vessel outlet at the steam reforming zone. The reformer also includes a helical tube extending about the first vessel. The helical tube has a first end connected to an oxygen-containing source and a second end connected to the first vessel at the partial oxidation reaction zone. Oxygen gas from an oxygen-containing source can be directed through the helical tube to the first vessel. A second vessel having a second vessel inlet and second vessel outlet is annularly disposed about the first vessel. The helical tube is disposed between the first vessel and the second vessel and gases from the first vessel can be directed through second vessel.

  14. Slow neutron mapping technique for level interface measurement

    NASA Astrophysics Data System (ADS)

    Zain, R. M.; Ithnin, H.; Razali, A. M.; Yusof, N. H. M.; Mustapha, I.; Yahya, R.; Othman, N.; Rahman, M. F. A.

    2017-01-01

    Modern industrial plant operations often require accurate level measurement of process liquids in production and storage vessels. A variety of advanced level indicators are commercially available to meet the demand, but these may not suit specific need of situations. The neutron backscatter technique is exceptionally useful for occasional and routine determination, particularly in situations such as pressure vessel with wall thickness up to 10 cm, toxic and corrosive chemical in sealed containers, liquid petroleum gas storage vessels. In level measurement, high energy neutrons from 241Am-Be radioactive source are beamed onto a vessel. Fast neutrons are slowed down mostly by collision with hydrogen atoms of material inside the vessel. Parts of thermal neutron are bounced back towards the source. By placing a thermal detector next to the source, these backscatter neutrons can be measured. The number of backscattered neutrons is directly proportional to the concentration of the hydrogen atoms in front of the neutron detector. As the source and detector moved by the matrix around the side of the vessel, interfaces can be determined as long as it involves a change in hydrogen atom concentration. This paper presents the slow neutron mapping technique to indicate level interface of a test vessel.

  15. Temporary Percutaneous Aortic Balloon Occlusion to Enhance Fluid Resuscitation Prior to Definitive Embolization of Post-Traumatic Liver Hemorrhage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsuoka, Shin; Uchiyama, Katsuhiro; Shima, Hideki

    2001-07-15

    We successfully stabilized severe hemorrhagic shock following traumatic liver injury by percutaneous transcarotid supraceliac aortic occlusion with a 5 Fr balloon catheter. Then we were able to perform transfemoral embolization therapy of the hepatic arterial bleeding source. Transient aortic occlusion using a balloon catheter appears to be a useful adjunct in select cases where stabilization of the patient is necessary to allow successful selective embolization of the bleeding source.

  16. Occult Mediastinal Great Vessel Trauma: The Value of Aortography Performed During Angiographic Screening for Blunt Cervical Vascular Trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Bauer, Jason R.; Cothren, C. Clay

    2005-05-15

    Purpose. To determine the value of aortography in the assessment of occult aortic and great vessel injuries when routinely performed during screening angiography for blunt cerebrovascular injury (BCVI). Methods. One hundred and one consecutive patients who received both aortography and screening four-vessel angiography over 4 years were identified retrospectively. Angiograms for these patients were evaluated, and the incidence of occult mediastinal vascular injury was determined. Results. Of the 101 patients, 6 (6%) had angiographically documented traumatic aortic injuries. Of these 6 patients, one injury (17%) was unsuspected prior to angiography. Four of the 6 (67%) also had BCVI. One additionalmore » patient also had an injury to a branch of the subclavian artery. Conclusion. Routine aortography during screening angiography for BCVI is not warranted due to the low incidence (1%) of occult mediastinal arterial injury. However, in the setting of a BCVI screening study and no CT scan of the chest, aortography may be advantageous.« less

  17. Response of humpback whales (Megaptera novaeangliae) to ramp-up of a small experimental air gun array.

    PubMed

    Dunlop, Rebecca A; Noad, Michael J; McCauley, Robert D; Kniest, Eric; Slade, Robert; Paton, David; Cato, Douglas H

    2016-02-15

    'Ramp-up', or 'soft start', is a mitigation measure used in seismic surveys and involves increasing the radiated sound level over 20-40 min. This study compared the behavioural response in migrating humpback whales to the first stages of ramp-up with the response to a 'constant' source, 'controls' (in which the array was towed but not operated) with groups in the absence of the source vessel used as the 'baseline'. Although the behavioural response, in most groups, resulted in an increase in distance from the source (potential avoidance), there was no evidence that either 'ramp-up' or the constant source at a higher level was superior for triggering whales to move away from the source vessel. 'Control' groups also responded suggesting the presence of the source vessel had some effect. However, the majority of groups appeared to avoid the source vessel at distances greater than the radius of most mitigation zones. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. An Hybrid 2-Stage Technique to Treat a Post-Traumatic Internal Carotid-Jugular Fistula.

    PubMed

    Massara, Mafalda; Barillà, David; De Caridi, Giovanni; Serra, Raffaele; Volpe, Alberto; Cutrupi, Andrea; Alberti, Antonino; Volpe, Pietro

    2017-01-01

    Penetrating wounds of the neck involving the carotid arteries can lead to 2 possible and important late sequelae: pseudoaneurysm formation and arteriovenous fistula (AVF), if an artery and the adjacent jugular vein are simultaneously lacerated. Traumatic AVF of the neck are rare complications and if untreated may cause congestive heart failure, cerebral ischemia, thromboembolism, or even rupture complications. Current treatment options for carotid-jugular AVF include operative repair, detachable balloon, coiling, or stenting. We present a hybrid 2-stage technique to treat an internal carotid-jugular vein fistula in a young woman, based first on carotid stenting to reduce the bleeding and reestablish an adequate cerebral perfusion, followed by stent removal and safe vessels surgical reconstruction through carotid-to-carotid bypass and vein repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. A review of microvascular ear replantation.

    PubMed

    Jung, Sung Won; Lee, Junsang; Oh, Suk Joon; Koh, Sung Hoon; Chung, Chul Hoon; Lee, Jong Wook

    2013-03-01

    Microvascular ear replantation is a significant challenge because of the small size of the vessels and the fact that traumatic amputations are frequently avulsed. The zone of trauma is therefore extended and the primary repair of the injured vessel is rendered unlikely. The purpose of this study is to review the literature of ear replantation. A review of the relevant literature that has been published since 1980 revealed 47 cases reported in 37 publications. We present 5 cases from our own experience and analyze a total 52 cases of microvascular ear replantation. The patient's age, sex, degree of amputation, cause of injury, ischemic time, method of arterial and venous anastomosis, complications, any additional outflow used, postoperative medications, the requirement for transfusions, and the number of hospital admission days are described. Successful microvascular ear replantations require anastomosis of the vessels if possible. Rather than a vein graft, primary repair of the vessels, or at least pedicled repair of the artery, should be considered to ensure flap survival. In addition, vein repair should be considered if possible to ensure the secure drainage of blood from the replant. With secure circulation, the replant can survive, resulting in a very satisfactory outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  20. Post traumatic inferior vena cava thrombosis: A case report and review of literature.

    PubMed

    Chakroun, Amine; Nakhli, Mohamed Said; Kahloul, Mohamed; Harrathi, Mohamed Amine; Naija, Walid

    2017-01-01

    Post traumatic inferior vena cava (IVC) thrombosis is a rare and not well described entity with nonspecific clinical presentation. It remains a therapeutic challenge in traumatic context because of haemorrhagic risk due to anticoagulation. We report a case of IVC thrombosis in an 18 year-old man who presented with liver injury following a traffic crash. The thrombosis was incidentally diagnosed on admission by computed tomography. The patient was managed conservatively without anticoagulation initially considering the increasing haemorrhagic risk. IVC filter placing was not possible because of the unusual localization of the thrombus. Unfractionated heparin was started on the third day after CT scan control showing stability of hepatic lesions with occurrence of a pulmonary embolism. The final outcome was good. The management of post traumatic IVC thrombosis is not well described. Medical approach consists in conservative management with anticoagulation which requires the absence of active bleeding lesions. Surgical treatment is commonly based on thrombectomy under extracorporeal circulation. Interventional vascular techniques have become an important alternative approach for the treatment of many vessel lesions. Their main advantages are the relative ease and speed with which they can be performed. Post traumatic IVC thrombosis is a rare condition. Its management is not well defined. Early anticoagulation should be discussed on a case-by-case basis. Other alternatives such IVC filter or surgical thrombectomy may be used when the bleeding risk is increased. The most serious risk is pulmonary embolism. Outcome can be favorable even with non surgical approaches. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. [Problems regarding the examination in forensic medicine].

    PubMed

    Naitow, M

    1989-10-01

    Problems encountered regarding the examination in forensic pathology are variable, even if the field of interest in limited to trauma alone. The most important problem appears to be the establishment of a causal relationship between the trauma and the death of the victim. From the materials I have contributed concerning examinations in forensic medicine, the problems inherent in the examination of the victim of traumatic shock may be introduced. The results from animal studies, which have been attempted to provide an experimental background to support the observations, are also discussed. My personal opinions on several trial cases in which there was a disagreement of opinion regarding the examination results will also be expressed. 1. Distinguishing death due to traumatic shock from death due to disease In the "Yacht school" incident, children with emotional disturbances and youths with a history of misconduct were treated with training which included physical punishment. Autopsy findings were compared between a 13-year old boy who was concluded to have died of traumatic shock from numerous beatings and a 21-year old youth who died of hemorrhagic pneumonia. In my opinion, a causative role of injury in the death was found in both cases. 2. Shock due to tourniquet This autopsy case concerns a 23-year-old male who entered a yoga training center, was tightly bound with a rope and died on the 8th day. Histological examination revealed thrombus formation in the small blood vessels and leukocyte agglutination within the blood vessels of the alveolar wall, suggesting DIC. While these findings were thought to be almost indistinguishable from those found in traumatic shock, the background conditions, including hunger, dehydration and hypothermia cannot be neglected in the evaluation. 3. Child abuse In one incident, a mother and her lover beat a 25-month old girl every day until her death. The original examination concluded that the cause of death was traumatic shock due to multiple trauma over the entire body caused by both adults. A second examination concluded that the cause of death was delayed suffocation due to binding of the chest and compression against a mattress. Based on an overall evaluation of the circumstances at the time of detection (including photographic evidence) as well as the contents of the statement made by the lover, I inferred that the head-down hanging of the child in the bathtub by the lover was directly related to the cause of death. In my opinion, the liability of the two adults in the crime was not the same.(ABSTRACT TRUNCATED AT 400 WORDS)

  2. Post-traumatic Stress Disorder by Gender and Veteran Status.

    PubMed

    Lehavot, Keren; Katon, Jodie G; Chen, Jessica A; Fortney, John C; Simpson, Tracy L

    2018-01-01

    Population-based data on the prevalence, correlates, and treatment utilization of post-traumatic stress disorder by gender and veteran status are limited. With changes in post-traumatic stress disorder diagnostic criteria in 2013, current information from a uniform data source is needed. This was a secondary analysis of the 2012-2013 National Epidemiologic Survey on Alcohol and Related Conditions-III, which consisted of in-person interviews that were conducted with a representative sample of U.S. adults. The Alcohol Use Disorder and Associated Disabilities Interview Schedule-DSM-5 Version was used to assess past-year and lifetime post-traumatic stress disorder among veterans (n=3,119) and civilians (n=32,982). Data were analyzed from January to March 2017. Adjusting for age and race/ethnicity, women veterans reported the highest rates of lifetime and past-year post-traumatic stress disorder (13.4%, 95% CI=8.8%, 17.9%, and 11.7%, 95% CI=7.1%, 16.4%) compared with women civilians (8.0%, 95% CI=7.4%, 8.6%, and 6.0%, 95% CI=5.5%, 6.6%); men veterans (7.7%, 95% CI=6.5%, 8.8%, and 6.7%, 95% CI=5.7%, 7.8%); and men civilians (3.4%, 95% CI=3.0%, 3.9%, and 2.6%, 95% CI=2.2%, 2.9%). Traumatic event exposure, correlates of lifetime post-traumatic stress disorder, and treatment seeking varied across subgroups. Men and women veterans were more likely than civilians to use a variety of treatment sources, with men civilians being least likely to seek treatment and men veterans exhibiting the longest delay in seeking treatment. Post-traumatic stress disorder is a common mental health disorder that varies by gender and veteran status. Women veterans' high rates of post-traumatic stress disorder highlight a critical target for prevention and intervention, whereas understanding treatment barriers for men veterans and civilians is necessary. Published by Elsevier Inc.

  3. The self-similar turbulent flow of low-pressure water vapor

    NASA Astrophysics Data System (ADS)

    Konyukhov, V. K.; Stepanov, E. V.; Borisov, S. K.

    2018-05-01

    We studied turbulent flows of water vapor in a pipe connecting two closed vessels of equal volume. The vessel that served as a source of water vapor was filled with adsorbent in the form of corundum ceramic balls. These ceramic balls were used to obtain specific conditions to lower the vapor pressure in the source vessel that had been observed earlier. A second vessel, which served as a receiver, was empty of either air or vapor before each vapor sampling. The rate of the pressure increase in the receiver vessel was measured in a series of six samplings performed with high precision. The pressure reduction rate in the source vessel was found to be three times lower than the pressure growth rate in the receiver vessel. We found that the pressure growth rates in all of the adjacent pairs of samples could be arranged in a combination that appeared to be identical for all pairs, and this revealed the existence of a rather interesting and peculiar self-similarity law for the sampling processes under consideration.

  4. Analysis and Design of a Photonic Biosensor for Mild Traumatic Brain Injury

    DTIC Science & Technology

    2013-03-01

    well developed. The basic process involves hydration of dry lipid, cholesterol, protein, or other component of the lipid membrane onto a vessel...surface from organic solvent (e.g., chloroform), thereby producing a thin film of dry lipid. This material is then hydrated to solution typically in an...such as by reaction with a polystyrene plate . A nucleic acid molecule may be aminated to promote binding to a polystyrene section of a housing via the

  5. WE-G-BRE-04: Gold Nanoparticle Induced Vasculature Damage for Proton Therapy: Monte Carlo Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Y; Paganetti, H; Schuemann, J

    2014-06-15

    Purpose: The aim of this work is to investigate the gold nanoparticle (GNP) induced vasculature damage in a proton beam. We compared the results using a clinical proton beam, 6MV photon beam and two kilovoltage photon beams. Methods: Monte Carlo simulations were carried out using TOPAS (TOol for PArticle Simulation) to obtain the spatial dose distribution in close proximity to GNPs up to 20μm distance. The spatial dose distribution was used as an input to calculate the additional dose deposited to the blood vessels. For this study, GNP induced vasculature damage is evaluated for three particle sources (proton beam, MVmore » photon beam and kV photon beam), various treatment depths for each particle source, various GNP uptakes and three different vessel diameters (8μm, 14μm and 20μm). Results: The result shows that for kV photon, GNPs induce more dose in the vessel wall for 150kVp photon source than 250kVp. For proton therapy, GNPs cause more dose in the vessel wall at shallower treatment depths. For 6MV photons, GNPs induce more dose in the vessel wall at deeper treatment depths. For the same GNP concentration and prescribed dose, the additional dose at the inner vessel wall is 30% more than the prescribed dose for the kVp photon source, 15% more for the proton source and only 2% more for the 6MV photon source. In addition, the dose from GNPs deceases sharper for proton therapy than kVp photon therapy as the distance from the vessel inner wall increases. Conclusion: We show in this study that GNPs can potentially be used to enhance radiation therapy by causing vasculature damage using clinical proton beams. The GNP induced damage for proton therapy is less than for the kVp photon source but significantly larger than for the clinical MV photon source.« less

  6. 40 CFR Table 3 to Subpart U of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 3 Table 3 to Subpart U of Part 63—Group 1 Storage Vessels at Existing...

  7. 40 CFR Table 3 to Subpart U of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 3 Table 3 to Subpart U of Part 63—Group 1 Storage Vessels at Existing...

  8. 40 CFR Table 2 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 2 Table 2 to Subpart JJJ of Part 63—Group 1 Storage Vessels...

  9. 40 CFR Table 2 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 2 Table 2 to Subpart JJJ of Part 63—Group 1 Storage Vessels...

  10. 40 CFR Table 2 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 2 Table 2 to Subpart JJJ of Part 63—Group 1 Storage Vessels at...

  11. 40 CFR Table 4 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Group 1 Storage Vessels at New... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 4 Table 4 to Subpart JJJ of Part 63—Group 1 Storage Vessels...

  12. 40 CFR Table 3 to Subpart U of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 3 Table 3 to Subpart U of Part 63—Group 1 Storage Vessels at Existing...

  13. 40 CFR Table 3 to Subpart U of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 3 Table 3 to Subpart U of Part 63—Group 1 Storage Vessels at Existing...

  14. 40 CFR Table 4 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Group 1 Storage Vessels at New... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 4 Table 4 to Subpart JJJ of Part 63—Group 1 Storage Vessels at...

  15. 40 CFR Table 2 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 2 Table 2 to Subpart JJJ of Part 63—Group 1 Storage Vessels at...

  16. 40 CFR Table 4 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Group 1 Storage Vessels at New... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 4 Table 4 to Subpart JJJ of Part 63—Group 1 Storage Vessels...

  17. 40 CFR Table 3 to Subpart U of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins Pt. 63, Subpt. U, Table 3 Table 3 to Subpart U of Part 63—Group 1 Storage Vessels at Existing...

  18. 40 CFR Table 2 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Group 1 Storage Vessels at Existing... SOURCE CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 2 Table 2 to Subpart JJJ of Part 63—Group 1 Storage Vessels at...

  19. Rheological effects of drag-reducing polymers improve cerebral blood flow and oxygenation after traumatic brain injury in rats.

    PubMed

    Bragin, Denis E; Kameneva, Marina V; Bragina, Olga A; Thomson, Susan; Statom, Gloria L; Lara, Devon A; Yang, Yirong; Nemoto, Edwin M

    2017-03-01

    Cerebral ischemia has been clearly demonstrated after traumatic brain injury (TBI); however, neuroprotective therapies have not focused on improvement of the cerebral microcirculation. Blood soluble drag-reducing polymers (DRP), prepared from high molecular weight polyethylene oxide, target impaired microvascular perfusion by altering the rheological properties of blood and, until our recent reports, has not been applied to the brain. We hypothesized that DRP improve cerebral microcirculation and oxygenation after TBI. DRP were studied in healthy and traumatized rat brains and compared to saline controls. Using in-vivo two-photon laser scanning microscopy over the parietal cortex, we showed that after TBI, nanomolar concentrations of intravascular DRP significantly enhanced microvascular perfusion and tissue oxygenation in peri-contusional areas, preserved blood-brain barrier integrity and protected neurons. The mechanisms of DRP effects were attributable to reduction of the near-vessel wall cell-free layer which increased near-wall blood flow velocity, microcirculatory volume flow, and number of erythrocytes entering capillaries, thereby reducing capillary stasis and tissue hypoxia as reflected by a reduction in NADH. Our results indicate that early reduction in CBF after TBI is mainly due to ischemia; however, metabolic depression of contused tissue could be also involved.

  20. Traumatic cervical internal carotid artery pseudoaneurysm in a child refractory to initial endovascular treatment: case report and technical considerations.

    PubMed

    Wang, Arthur; Santarelli, Justin G; Stiefel, Michael F

    2016-12-01

    Optimal management of extracranial carotid artery dissections (eCAD) in pediatric patients is not well documented, and endovascular interventions are rarely reported. A 10-year-old girl sustained multiple systemic injuries in a motor vehicle accident, including an eCAD with pseudoaneurysm. She initially failed both aspirin and endovascular stenting with progressive enlargement of a traumatic cervical carotid pseudoaneurysm and stenosis. Second-stage endovascular stent placement with coiling resulted in successful occlusion of the pseudoaneurysm. At 30-month imaging follow-up, the parent vessel remained patent with no evidence of the pseudoaneurysm. In the setting of poly-trauma, management of eCAD can be complex especially in the pediatric population. There is little data on the endovascular treatment of eCAD in children. Failed endovascular therapies are extremely rare. Our report supports surveillance imaging as repeat endovascular treatment may be necessary.

  1. Spontaneous right hepatic artery branch gallbladder fistula revealed by haemobilia and upper cataclysmic gastrointestinal bleeding.

    PubMed

    Landolsi, Sana; Landolsi, Manel; Mannai, Saber

    2018-01-03

    Spontaneous right hepatic artery branch gallbladder fistula is a rare condition. Our case reported a spontaneous fistula between the right branch of the hepatic artery and the gall bladder. It constitutes a rare cause of haemobilia. In fact, the most common aetiology of haemobilia is traumatic or iatrogenic secondary to hepatobiliary surgery or interventions. Diagnosis of vascular-biliary fistula is not easy. The gallbladder endoluminal clot can mimic a mass, as in our patient. Selective arterial angiography is helpful in identifying the source of gastrointestinal haemorrhage. It can demonstrate the presence of arteriobiliary fistula. The differential diagnosis is arterial pseudoaneurysm in the vicinity of the vessel. Mini-invasive treatment of this fistula constitutes the best treatment. We here report a case of haemobilia with upper cataclysmic gastrointestinal bleeding revealing a spontaneous fistula between the right branch of the hepatic artery and the gall bladder. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. 40 CFR Table 1 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Receivers at Existing Sources 1 Table 1 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 1 Table 1 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at Existing Sources...

  3. 40 CFR Table 1 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Receivers at Existing Sources 1 Table 1 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 1 Table 1 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at Existing Sources...

  4. 40 CFR Table 1 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Receivers at Existing Sources 1 Table 1 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 1 Table 1 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at Existing Sources...

  5. 40 CFR Table 1 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Receivers at Existing Sources 1 Table 1 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 1 Table 1 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at Existing Sources...

  6. 40 CFR Table 1 to Subpart V of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Receivers at Existing Sources 1 Table 1 to Subpart V of Part 61 Protection of Environment ENVIRONMENTAL... POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) Pt. 61, Subpt. V, Table 1 Table 1 to Subpart V of Part 61—Surge Control Vessels and Bottoms Receivers at Existing Sources...

  7. Assessment of Students with Traumatic Brain Injury

    ERIC Educational Resources Information Center

    Chesire, David J.; Buckley, Valerie A.; Canto, Angela I.

    2011-01-01

    The incidence of brain injuries, as well as their impact on individuals who sustain them, has received growing attention from American media in recent years. This attention is likely the result of high profile individuals suffering brain injuries. Greater public awareness of traumatic brain injuries (TBIs) has also been promoted by sources such as…

  8. 40 CFR Table 3 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Group 1 Storage Vessels at Existing... Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 3 Table 3 to Subpart JJJ of Part 63—Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics...

  9. 40 CFR Table 3 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Group 1 Storage Vessels at Existing... Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 3 Table 3 to Subpart JJJ of Part 63—Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics...

  10. 40 CFR Table 3 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Group 1 Storage Vessels at Existing... Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 3 Table 3 to Subpart JJJ of Part 63—Group 1 Storage Vessels at Existing Affected Sources Producing the Listed...

  11. 40 CFR Table 3 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Group 1 Storage Vessels at Existing... Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 3 Table 3 to Subpart JJJ of Part 63—Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics...

  12. 40 CFR Table 3 to Subpart Jjj of... - Group 1 Storage Vessels at Existing Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Group 1 Storage Vessels at Existing... Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 3 Table 3 to Subpart JJJ of Part 63—Group 1 Storage Vessels at Existing Affected Sources Producing the Listed...

  13. 40 CFR Table 2 to Subpart H of... - Surge Control Vessels and Bottoms Receivers at Existing Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Surge Control Vessels and Bottoms Receivers at Existing Sources 2 Table 2 to Subpart H of Part 63 Protection of Environment ENVIRONMENTAL... Equipment Leaks Pt. 63, Subpt. H, Table 2 Table 2 to Subpart H of Part 63—Surge Control Vessels and Bottoms...

  14. 40 CFR Table 3 to Subpart H of... - Surge Control Vessels and Bottoms Receivers at New Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Surge Control Vessels and Bottoms Receivers at New Sources 3 Table 3 to Subpart H of Part 63 Protection of Environment ENVIRONMENTAL... Equipment Leaks Pt. 63, Subpt. H, Table 3 Table 3 to Subpart H of Part 63—Surge Control Vessels and Bottoms...

  15. 40 CFR 63.1432 - Storage vessel provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Storage vessel provisions. 63.1432....1432 Storage vessel provisions. (a) For each storage vessel located at an affected source, the owner or operator shall comply with the HON storage vessel requirements of §§ 63.119 through 63.123 and the HON leak...

  16. Restless 'rest': intrinsic sensory hyperactivity and disinhibition in post-traumatic stress disorder.

    PubMed

    Clancy, Kevin; Ding, Mingzhou; Bernat, Edward; Schmidt, Norman B; Li, Wen

    2017-07-01

    Post-traumatic stress disorder is characterized by exaggerated threat response, and theoretical accounts to date have focused on impaired threat processing and dysregulated prefrontal-cortex-amygdala circuitry. Nevertheless, evidence is accruing for broad, threat-neutral sensory hyperactivity in post-traumatic stress disorder. As low-level, sensory processing impacts higher-order operations, such sensory anomalies can contribute to widespread dysfunctions, presenting an additional aetiological mechanism for post-traumatic stress disorder. To elucidate a sensory pathology of post-traumatic stress disorder, we examined intrinsic visual cortical activity (based on posterior alpha oscillations) and bottom-up sensory-driven causal connectivity (Granger causality in the alpha band) during a resting state (eyes open) and a passive, serial picture viewing state. Compared to patients with generalized anxiety disorder (n = 24) and healthy control subjects (n = 20), patients with post-traumatic stress disorder (n = 25) demonstrated intrinsic sensory hyperactivity (suppressed posterior alpha power, source-localized to the visual cortex-cuneus and precuneus) and bottom-up inhibition deficits (reduced posterior→frontal Granger causality). As sensory input increased from resting to passive picture viewing, patients with post-traumatic stress disorder failed to demonstrate alpha adaptation, highlighting a rigid, set mode of sensory hyperactivity. Interestingly, patients with post-traumatic stress disorder also showed heightened frontal processing (augmented frontal gamma power, source-localized to the superior frontal gyrus and dorsal cingulate cortex), accompanied by attenuated top-down inhibition (reduced frontal→posterior causality). Importantly, not only did suppressed alpha power and bottom-up causality correlate with heightened frontal gamma power, they also correlated with increased severity of sensory and executive dysfunctions (i.e. hypervigilance and impulse control deficits, respectively). Therefore, sensory aberrations help construct a vicious cycle in post-traumatic stress disorder that is in action even at rest, implicating dysregulated triangular sensory-prefrontal-cortex-amygdala circuitry: intrinsic sensory hyperactivity and disinhibition give rise to frontal overload and disrupt executive control, fuelling and perpetuating post-traumatic stress disorder symptoms. Absent in generalized anxiety disorder, these aberrations highlight a unique sensory pathology of post-traumatic stress disorder (ruling out effects merely reflecting anxious hyperarousal), motivating new interventions targeting sensory processing and the sensory brain in these patients. © The Author (2017). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Repair of Traumatic Skeletal Muscle Injury with Bone-Marrow-Derived Mesenchymal Stem Cells Seeded on Extracellular Matrix

    DTIC Science & Technology

    2010-06-02

    fully restored muscle fibers and blood vessels is not known; however, FIG. 4. von Willebrand factor (vWF). Masson’s Trichrome stain of sections of...dystrophic skeletal muscle is able to partially restore expression of dystrophin within the fibers .30,35,49,50 Conflict exists as to whether or not the...significantly higher number of fibers expressed in regions closer to the border with native muscle tissue indicate that engraftment of cells was not the main

  18. Superficial Palmar Arch Aneurysm after Carpal Tunnel Decompression, a Rare Complication: A Case Report

    PubMed Central

    Gull, S.; Spence, R. A. J.; Loan, W.

    2011-01-01

    False aneurysms of the palmar arteries are rare. They are usually associated with traumatic injuries to the hand vasculature. We present a case of superficial palmar arch aneurysm (SPAA), complicating carpal tunnel decompression which presented as a pulsatile mass at the site of previous surgery. Initial diagnosis was made on clinical examination and confirmed on doppler ultrasound (US) and computed tomographic angiography (CTA). The feeding vessel of the aneurysm was subsequently occluded using coil embolization. PMID:21547251

  19. 29 CFR 1915.93 - Utilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shall ascertain from responsible vessel's representatives, having knowledge of the condition of the... power. (1) When the vessel is supplied with electric power from a source outside the vessel, the... representatives, having knowledge of the condition of the vessel's electrical system, that all circuits to be...

  20. [Occupational risk according to occupational traumatism parameters in Russia].

    PubMed

    Tikhonova, G I; Churanova, A N; Gorchakova, T Iu

    2012-01-01

    The article covers analysis of occupational traumatism in Russia over 2009 in concern with economic activity types, with small enterprises accent. Based on method adapted to national information sources and assessing statistics reliability in countries with imperfect accounting, the authors demonstrated that with various hypotheses occupational accidents risk in Russian Federation is considerably higher than the registered one.

  1. The Effectiveness of Academic Accommodations for School-Age Students with Traumatic Brain Injury. EBP Briefs. Volume 10, Issue 4

    ERIC Educational Resources Information Center

    Bush, Erin J.; Burge, Emily A.

    2016-01-01

    Clinical Question: What are the evidence-based classroom accommodations for school-age students with traumatic brain injury who are struggling academically, and do they improve academic performance as compared to no classroom accommodations? Method: Literature Review. Study Sources: Google Scholar, ASHA, PubMed, Academic Search Premier. Search…

  2. Parents' Faith and Hope during the Pediatric Palliative Phase and the Association with Long-Term Parental Adjustment.

    PubMed

    van der Geest, Ivana M M; van den Heuvel-Eibrink, Marry M; Falkenburg, Nette; Michiels, Erna M C; van Vliet, Liesbeth; Pieters, Rob; Darlington, Anne-Sophie E

    2015-05-01

    The loss of a child is associated with an increased risk for developing psychological problems. However, studies investigating the impact of parents' faith and hope for a cure during the palliative phase on long-term parental psychological functioning are limited. The study's objective was to explore the role of faith and hope as a source of coping and indicator of long-term parental adjustment. Eighty-nine parents of 57 children who died of cancer completed questionnaires retrospectively, exploring faith, hope, and sources of coping, and measuring parents' current level of grief and depression. For 19 parents (21%) faith was very important during the palliative phase. The majority of parents remained hopeful for a meaningful time with their child (n=68, 76%); a pain-free death (n=58, 65%); and a cure (n=30, 34%). Their child (n=70, 79%) was parents' main source of coping. Twelve parents (14%) suffered from traumatic grief, and 22 parents (25%) showed symptoms of depression. Parents' faith was not associated with less long-term traumatic grief (OR=0.86, p=0.51) or symptoms of depression (OR=0.95, p=0.74), and parents' hope for a cure was not related to more long-term traumatic grief (OR=1.07, p=0.71) or symptoms of depression (OR=1.12, p=0.47). Faith was important for a minority of parents and was not associated with less long-term traumatic grief or symptoms of depression. The majority of parents remained hopeful. Hope for a cure was not associated with more long-term traumatic grief or symptoms of depression.

  3. 40 CFR Table 5 to Subpart G of... - Group 1 Storage Vessels at Existing Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Group 1 Storage Vessels at Existing Sources 5 Table 5 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for...

  4. 40 CFR Table 5 to Subpart G of... - Group 1 Storage Vessels at Existing Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Group 1 Storage Vessels at Existing Sources 5 Table 5 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for...

  5. 40 CFR Table 5 to Subpart G of... - Group 1 Storage Vessels at Existing Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Group 1 Storage Vessels at Existing Sources 5 Table 5 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for...

  6. 40 CFR Table 5 to Subpart G of... - Group 1 Storage Vessels at Existing Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Group 1 Storage Vessels at Existing Sources 5 Table 5 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for...

  7. 40 CFR Table 5 to Subpart G of... - Group 1 Storage Vessels at Existing Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Group 1 Storage Vessels at Existing Sources 5 Table 5 to Subpart G of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards for...

  8. 40 CFR 61.270 - Applicability and designation of sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for Benzene Emissions From Benzene Storage Vessels § 61.270 Applicability and designation of sources. (a) The source to which this subpart applies is each storage vessel that is storing benzene having a... Benzene, ASTM D835-85 for Refined Benzene-485, ASTM D2359-85a or 93 for Refined Benzene-535, and ASTM...

  9. 40 CFR 61.270 - Applicability and designation of sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for Benzene Emissions From Benzene Storage Vessels § 61.270 Applicability and designation of sources. (a) The source to which this subpart applies is each storage vessel that is storing benzene having a... Benzene, ASTM D835-85 for Refined Benzene-485, ASTM D2359-85a or 93 for Refined Benzene-535, and ASTM...

  10. 40 CFR 61.270 - Applicability and designation of sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for Benzene Emissions From Benzene Storage Vessels § 61.270 Applicability and designation of sources. (a) The source to which this subpart applies is each storage vessel that is storing benzene having a... Benzene, ASTM D835-85 for Refined Benzene-485, ASTM D2359-85a or 93 for Refined Benzene-535, and ASTM...

  11. 40 CFR 61.270 - Applicability and designation of sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... for Benzene Emissions From Benzene Storage Vessels § 61.270 Applicability and designation of sources. (a) The source to which this subpart applies is each storage vessel that is storing benzene having a... Benzene, ASTM D835-85 for Refined Benzene-485, ASTM D2359-85a or 93 for Refined Benzene-535, and ASTM...

  12. 40 CFR 61.270 - Applicability and designation of sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for Benzene Emissions From Benzene Storage Vessels § 61.270 Applicability and designation of sources. (a) The source to which this subpart applies is each storage vessel that is storing benzene having a... Benzene, ASTM D835-85 for Refined Benzene-485, ASTM D2359-85a or 93 for Refined Benzene-535, and ASTM...

  13. 40 CFR 63.1404 - Storage vessel provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Storage vessel provisions. 63.1404... Standards for Hazardous Air Pollutant Emissions: Manufacture of Amino/Phenolic Resins § 63.1404 Storage vessel provisions. (a) Emission standards. For each storage vessel located at a new affected source that...

  14. 40 CFR 63.1404 - Storage vessel provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Storage vessel provisions. 63.1404... Standards for Hazardous Air Pollutant Emissions: Manufacture of Amino/Phenolic Resins § 63.1404 Storage vessel provisions. (a) Emission standards. For each storage vessel located at a new affected source that...

  15. 40 CFR 60.16 - Priority list.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Categories Priority Number 1 Source Category 1. Synthetic Organic Chemical Manufacturing Industry (SOCMI) and Volatile Organic Liquid Storage Vessels and Handling Equipment (a) SOCMI unit processes (b) Volatile organic liquid (VOL) storage vessels and handling equipment (c) SOCMI fugitive sources (d) SOCMI secondary...

  16. 78 FR 16180 - Seaway Regulations and Rules: Periodic Update, Various Categories

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... flame or than can produce a source of ignition, cutting or welding, can be carried out on any vessels at... source of ignition, cutting or welding, is carried out by any vessel on any designated St. Lawrence...

  17. Untangling the Source of Ouch and Itch

    MedlinePlus

    ... Untangling the Source of Ouch and Itch Inside Life Science View All Articles | Inside Life Science Home Page Untangling the Source of Ouch and ... Traumatic Injury: How the Body Responds This Inside Life Science article also appears on LiveScience . Learn about related ...

  18. 40 CFR 63.1314 - Storage vessel provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Storage vessel provisions. 63.1314... Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1314 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  19. 40 CFR 63.484 - Storage vessel provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Storage vessel provisions. 63.484... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.484 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  20. 40 CFR 63.1432 - Storage vessel provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Storage vessel provisions. 63.1432... Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1432 Storage vessel provisions. (a) For each storage vessel located at an affected source, the owner or operator shall comply...

  1. 40 CFR 63.484 - Storage vessel provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Storage vessel provisions. 63.484... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.484 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  2. 40 CFR 63.484 - Storage vessel provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Storage vessel provisions. 63.484... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.484 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  3. 40 CFR 63.484 - Storage vessel provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Storage vessel provisions. 63.484... Standards for Hazardous Air Pollutant Emissions: Group I Polymers and Resins § 63.484 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  4. 40 CFR 63.1314 - Storage vessel provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Storage vessel provisions. 63.1314... Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins § 63.1314 Storage vessel provisions. (a) This section applies to each storage vessel that is assigned to an affected source, as...

  5. 40 CFR 63.1432 - Storage vessel provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Storage vessel provisions. 63.1432... Standards for Hazardous Air Pollutant Emissions for Polyether Polyols Production § 63.1432 Storage vessel provisions. (a) For each storage vessel located at an affected source, the owner or operator shall comply...

  6. Memory Restoration Using Computerized Cognitive Training after Pediatric Traumatic Brain Injury: A Review of the Evidence. EBP Briefs. Volume 12, Issue 3

    ERIC Educational Resources Information Center

    Lundine, Jennifer P.

    2017-01-01

    Clinical Question: For children and adolescents with memory impairments after traumatic brain injury (TBI), do computerized cognitive training (CCT) programs used in conjunction with traditional therapy vs. traditional therapy alone lead to memory gains in daily activities? Method: Literature Review. Study Sources: Google Scholar, CINAHL via…

  7. Core Vessel Insert Handling Robot for the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graves, Van B; Dayton, Michael J

    2011-01-01

    The Spallation Neutron Source provides the world's most intense pulsed neutron beams for scientific research and industrial development. Its eighteen neutron beam lines will eventually support up to twenty-four simultaneous experiments. Each beam line consists of various optical components which guide the neutrons to a particular instrument. The optical components nearest the neutron moderators are the core vessel inserts. Located approximately 9 m below the high bay floor, these inserts are bolted to the core vessel chamber and are part of the vacuum boundary. They are in a highly radioactive environment and must periodically be replaced. During initial SNS construction,more » four of the beam lines received Core Vessel Insert plugs rather than functional inserts. Remote replacement of the first Core Vessel Insert plug was recently completed using several pieces of custom-designed tooling, including a highly complicated Core Vessel Insert Robot. The design of this tool are discussed.« less

  8. Fever in trauma patients: evaluation of risk factors, including traumatic brain injury.

    PubMed

    Bengualid, Victoria; Talari, Goutham; Rubin, David; Albaeni, Aiham; Ciubotaru, Ronald L; Berger, Judith

    2015-03-01

    The role of fever in trauma patients remains unclear. Fever occurs as a response to release of cytokines and prostaglandins by white blood cells. Many factors, including trauma, can trigger release of these factors. To determine whether (1) fever in the first 48 hours is related to a favorable outcome in trauma patients and (2) fever is more common in patients with head trauma. Retrospective study of trauma patients admitted to the intensive care unit for at least 2 days. Data were analyzed by using multivariate analysis. Of 162 patients studied, 40% had fever during the first 48 hours. Febrile patients had higher mortality rates than did afebrile patients. When adjusted for severity of injuries, fever did not correlate with mortality. Neither the incidence of fever in the first 48 hours after admission to the intensive care unit nor the number of days febrile in the unit differed between patients with and patients without head trauma (traumatic brain injury). About 70% of febrile patients did not have a source found for their fever. Febrile patients without an identified source of infection had lower peak white blood cell counts, lower maximum body temperature, and higher minimum platelet counts than did febrile patients who had an infectious source identified. The most common infection was pneumonia. No relationship was found between the presence of fever during the first 48 hours and mortality. Patients with traumatic brain injury did not have a higher incidence of fever than did patients without traumatic brain injury. About 30% of febrile patients had an identifiable source of infection. Further studies are needed to understand the origin and role of fever in trauma patients. ©2015 American Association of Critical-Care Nurses.

  9. [Post-traumatic pseudoaneurysm of an anomalous right hepatic artery with arteriobiliary fistula and hemobilia].

    PubMed

    Bober, J; Vrzgula, A; Samek, P; Mach, P

    1999-09-01

    The authors describe a rare case of posttraumatic pseudoaneurysm of an anomaly arising right hepatic artery accompanied with arteriobiliary fistula. Treacherousness of this case was given by anomaly origin of the affected vessel. Thirty-four year old female has been treated at the author's department after sustained knife abdominal injury. Before our treatment, she was twice operated at the other hospital for haemoperitoneum and subhepatic abscess with haemobilia. The patient was transferred to the 1st department of surgery in Kosice because of septic shock, right-lobe hepatic abscess and repeated haemobilia. Selective hepatico-mesentericography revealed the cause of haemobilia. At the operation a double ligation of anomaly right hepatic artery was carried out together with closure of arteriobiliary fistula via choledochotomy. Haemobilia was not seen after surgery and the patient was discharged without any signs of liver disfunction. Repeated angiography showed closure of anomaly arising vessel.

  10. Microwave electron cyclotron electron resonance (ECR) ion source with a large, uniformly distributed, axially symmetric, ECR plasma volume

    DOEpatents

    Alton, Gerald D.

    1996-01-01

    An electron cyclotron resonance (ECR) ion source includes a primary mirror coil disposed coaxially around a vacuum vessel in which a plasma is induced and introducing a solenoidal ECR-producing field throughout the length of the vacuum vessel. Radial plasma confinement is provided by a multi-cusp, multi-polar permanent magnet array disposed azimuthally around the vessel and within the primary mirror coil. Axial confinement is provided either by multi-cusp permanent magnets at the opposite axial ends of the vessel, or by secondary mirror coils disposed on opposite sides of the primary coil.

  11. Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

    NASA Astrophysics Data System (ADS)

    Ziock, K. P.; Boehnen, C. B.; Ernst, J. M.; Fabris, L.; Hayward, J. P.; Karnowski, T. P.; Paquit, V. C.; Patlolla, D. R.; Trombino, D. G.

    2016-01-01

    Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. The complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.

  12. Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

    DOE PAGES

    Ziock, Klaus -Peter; Boehnen, Chris Bensing; Ernst, Joseph M.; ...

    2015-09-05

    Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combinedmore » gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.« less

  13. [Endovascular and surgical treatment of a patient with traumatic rupture of the aorta and hepatic artery].

    PubMed

    Chernaya, N R; Muslimov, R Sh; Selina, I E; Kokov, L S; Vladimirova, E S; Navruzbekov, M S; Gulyaev, V A

    2016-01-01

    Traumatic rupture of the aorta is the second most common cause of death in closed chest injury. The latest findings of autopsy showed that 80% of lethal outcomes in aortic injury occur in the prehospital period. Taking into consideration the incidence and high rate of death prior to the diagnosis stage, aortic rupture in closed thoracic injury is an important problem. Due to the characteristic mechanism of the development (during sharp deceleration of the body) this type of traumatic lesion of the aorta became known as "deceleration syndrome". The most vulnerable to tension aortic portion is its neck where the mobile part of the thoracic aorta is connected to the fixed arch in the place of the arterial ligament attachment. Open surgical intervention in patients with severe closed chest injury (often concomitant injury) is associated with high mortality and complications. Currently endovascular prosthetic repair of the aorta is a method of choice at the primary stage of treatment of patients with aortic injury. In this article we present a rare case report of concomitant lesion of large vessels (the descending aortic portion and proper hepatic artery) in a patient with severe concomitant injury, as well as peculiarities of diagnosis and combined treatment (endovascular prosthetic repair of the aorta and hepatic artery with an aotovein).

  14. Rheological effects of drag-reducing polymers improve cerebral blood flow and oxygenation after traumatic brain injury in rats

    PubMed Central

    Kameneva, Marina V; Bragina, Olga A; Thomson, Susan; Statom, Gloria L; Lara, Devon A; Yang, Yirong; Nemoto, Edwin M

    2016-01-01

    Cerebral ischemia has been clearly demonstrated after traumatic brain injury (TBI); however, neuroprotective therapies have not focused on improvement of the cerebral microcirculation. Blood soluble drag-reducing polymers (DRP), prepared from high molecular weight polyethylene oxide, target impaired microvascular perfusion by altering the rheological properties of blood and, until our recent reports, has not been applied to the brain. We hypothesized that DRP improve cerebral microcirculation and oxygenation after TBI. DRP were studied in healthy and traumatized rat brains and compared to saline controls. Using in-vivo two-photon laser scanning microscopy over the parietal cortex, we showed that after TBI, nanomolar concentrations of intravascular DRP significantly enhanced microvascular perfusion and tissue oxygenation in peri-contusional areas, preserved blood–brain barrier integrity and protected neurons. The mechanisms of DRP effects were attributable to reduction of the near-vessel wall cell-free layer which increased near-wall blood flow velocity, microcirculatory volume flow, and number of erythrocytes entering capillaries, thereby reducing capillary stasis and tissue hypoxia as reflected by a reduction in NADH. Our results indicate that early reduction in CBF after TBI is mainly due to ischemia; however, metabolic depression of contused tissue could be also involved. PMID:28155574

  15. 47 CFR 80.956 - Required frequencies and uses.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vessel's service. (4) One channel for receiving marine navigational warnings for the area of operation... more sources of energy and associated antennas and control equipment. The radiotelephone station, exclusive of the antennas and source of energy, must be located as high as practicable on the vessel...

  16. 47 CFR 80.956 - Required frequencies and uses.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vessel's service. (4) One channel for receiving marine navigational warnings for the area of operation... more sources of energy and associated antennas and control equipment. The radiotelephone station, exclusive of the antennas and source of energy, must be located as high as practicable on the vessel...

  17. 47 CFR 80.956 - Required frequencies and uses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vessel's service. (4) One channel for receiving marine navigational warnings for the area of operation... more sources of energy and associated antennas and control equipment. The radiotelephone station, exclusive of the antennas and source of energy, must be located as high as practicable on the vessel...

  18. 47 CFR 80.956 - Required frequencies and uses.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vessel's service. (4) One channel for receiving marine navigational warnings for the area of operation... more sources of energy and associated antennas and control equipment. The radiotelephone station, exclusive of the antennas and source of energy, must be located as high as practicable on the vessel...

  19. 47 CFR 80.956 - Required frequencies and uses.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vessel's service. (4) One channel for receiving marine navigational warnings for the area of operation... more sources of energy and associated antennas and control equipment. The radiotelephone station, exclusive of the antennas and source of energy, must be located as high as practicable on the vessel...

  20. 40 CFR Table 5 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics 5 Table 5 to Subpart JJJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  1. 40 CFR Table 5 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics 5 Table 5 to Subpart JJJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  2. 40 CFR Table 5 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 12 2014-07-01 2014-07-01 false Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics 5 Table 5 to Subpart JJJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  3. 40 CFR Table 5 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 12 2013-07-01 2013-07-01 false Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics 5 Table 5 to Subpart JJJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  4. 40 CFR Table 5 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Group 1 Storage Vessels at New Affected Sources Producing the Listed Thermoplastics 5 Table 5 to Subpart JJJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE...

  5. Tau Processing by Mural Cells in Traumatic Brain Injury and Alzheimer’s Disease

    DTIC Science & Technology

    2017-10-01

    Cerebrovessels were treated with recombinant human tau (5ng/ml) for 1 hour at 37oC and total tau uptake was assessed in the lysates via ELISA . We observed a...to 5ng/ml recombinant human tau (rhtau-441) for 1 hour at 37oC. Lysates were analyzed for total tau content by ELISA and normalized to total protein...and 6 months post-last injury). Brain vessels were analyzed for PDGFRβ and α-SMC-actin content by ELISA and normalized to total protein using the

  6. 46 CFR 28.375 - Emergency source of electrical power.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... COMMERCIAL FISHING INDUSTRY VESSELS Requirements for Vessels Which Have Their Keel Laid or Are at a Similar... systems; (3) Bilge pumps; (4) Fire protection and detection systems, including fire pumps; (5... (11.0 meters) in length need only supply communication equipment by an emergency source of electrical...

  7. 46 CFR 28.375 - Emergency source of electrical power.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... COMMERCIAL FISHING INDUSTRY VESSELS Requirements for Vessels Which Have Their Keel Laid or Are at a Similar... systems; (3) Bilge pumps; (4) Fire protection and detection systems, including fire pumps; (5... (11.0 meters) in length need only supply communication equipment by an emergency source of electrical...

  8. 46 CFR 28.375 - Emergency source of electrical power.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... COMMERCIAL FISHING INDUSTRY VESSELS Requirements for Vessels Which Have Their Keel Laid or Are at a Similar... systems; (3) Bilge pumps; (4) Fire protection and detection systems, including fire pumps; (5... (11.0 meters) in length need only supply communication equipment by an emergency source of electrical...

  9. 46 CFR 28.375 - Emergency source of electrical power.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... COMMERCIAL FISHING INDUSTRY VESSELS Requirements for Vessels Which Have Their Keel Laid or Are at a Similar... systems; (3) Bilge pumps; (4) Fire protection and detection systems, including fire pumps; (5... (11.0 meters) in length need only supply communication equipment by an emergency source of electrical...

  10. 46 CFR 28.375 - Emergency source of electrical power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COMMERCIAL FISHING INDUSTRY VESSELS Requirements for Vessels Which Have Their Keel Laid or Are at a Similar... systems; (3) Bilge pumps; (4) Fire protection and detection systems, including fire pumps; (5... (11.0 meters) in length need only supply communication equipment by an emergency source of electrical...

  11. Ethnic discrimination and Latino depression: The mediating role of traumatic stress symptoms and alcohol use.

    PubMed

    Torres, Lucas; Vallejo, Leticia G

    2015-10-01

    Previous research has established a link between ethnic discrimination and poor mental health, yet the process by which this relationship occurs remains unclear. It has been hypothesized that the potential mechanisms accounting for the negative consequences of ethnic discrimination may be through stress responses and health behaviors (Pascoe & Smart Richman, 2009). The present study sought to examine the role of traumatic stress symptoms and alcohol use in mediating the relationship between ethnic discrimination and depressive symptoms. Two aspects of ethnic discrimination were assessed, namely source of discrimination and reaction to discrimination. The sample for the current study included 244 adult Latinos averaging approximately 40 years of age (SD = 15.29; range 18-85). Participants, which were comprised of mainly women (66%, n = 156), completed a series of paper-and-pencil questionnaires. Multiple mediator analyses revealed that, among U.S.-born but not foreign-born Latinos, both source of discrimination and reaction to discrimination were related to increased traumatic stress symptoms, which, in turn, was associated with depressive symptomatology. The traumatic stress symptoms pathway showed a robust indirect effect while alcohol use was not a statistically significant mediator. These major findings suggest that, while ethnic discrimination has a direct effect on depression, increased traumatic stress can account for this relationship particularly for U.S.-born Latinos. The findings are discussed within a stress and coping framework. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  12. Trauma exposure and endothelial function among midlife women.

    PubMed

    Thurston, Rebecca C; Barinas-Mitchell, Emma; von Känel, Roland; Chang, Yuefang; Koenen, Karestan C; Matthews, Karen A

    2018-04-01

    Trauma is a potent exposure that can have implications for health. However, little research has considered whether trauma exposure is related to endothelial function, a key process in the pathophysiology of cardiovascular disease (CVD). We tested whether exposure to traumatic experiences was related to poorer endothelial function among midlife women, independent of CVD risk factors, demographic factors, psychosocial factors, or a history of childhood abuse. In all, 272 nonsmoking perimenopausal and postmenopausal women aged 40 to 60 years without clinical CVD completed the Brief Trauma Questionnaire, the Child Trauma Questionnaire, physical measures, a blood draw, and a brachial ultrasound for assessment of brachial artery flow-mediated dilation (FMD). Relations between trauma and FMD were tested in linear regression models controlling for baseline vessel diameter, demographics, depression/anxiety, CVD risk factors, health behaviors, and, additionally, a history of childhood abuse. Over 60% of the sample had at least one traumatic exposure, and 18% had three or more exposures. A greater number of traumatic exposures was associated with lower FMD, indicating poorer endothelial function in multivariable models (beta, β [standard error, SE] -1.05 [0.40], P = 0.01). Relations between trauma exposure and FMD were particularly pronounced for three or more trauma exposures (b [SE] -1.90 [0.71], P = 0.008, relative to no exposures, multivariable). A greater number of traumatic exposures were associated with poorer endothelial function. Relations were not explained by demographics, CVD risk factors, mood/anxiety, or a by history of childhood abuse. Women with greater exposure to trauma over life maybe at elevated CVD risk.

  13. Neuropathology and brain weight in traumatic-crush asphyxia.

    PubMed

    Al-Sarraj, Safa; Laxton, Ross; Swift, Ben; Kolar, Alexander J; Chapman, Rob C; Fegan-Earl, Ashley W; Cary, Nat R B

    2017-11-01

    Traumatic (crush) asphyxia is a rare condition caused by severe compression of the chest and trunk leading to often extreme so-called asphyxial signs, including cyanosis in head and neck regions, multiple petechiae, and subconjunctival haemorrhage as well as neurological manifestations. To investigate the neuropathology and brain weight in traumatic asphyxia caused by different accidents such as industrial accidents and road traffic collision. Post mortem records of 20 cases of traumatic asphyxia (TA) resulting from different causes of which four brains are available for comprehensive neuropathological examination. The expected brain weights for given body height and associated 95% confidence range were calculated according to the following formula: baseline brain weight (BBW) + body height x rate (g/cm). The 95% confidence range was calculated by adding and subtracting the standard error (SE) x 1.96 (7-8). There was a trend for higher brain weight in the TA cohort but it was not significant (1494 g vs 1404 g, p = 0.1). The upper limits of the brain weight of 95% confidence was 1680 g vs 1660 g, p = 0.9. The neuropathological examination of four available brains from the TA cohort showed severe congestion of blood vessels, perivascular haemorrhages and occasional βAPP deposits consistent with early axonal disruption. Brain examination is informative as part of investigation of TA. Developing ischaemic changes and an increase in brain weight are the most likely indicators of a prolonged period of patient's survival. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  14. Diagnosis and Treatment of Traumatic Cerebrovascular Injury: Pitfalls in the Management of Neurotrauma.

    PubMed

    Kobata, Hitoshi

    2017-08-15

    Traumatic cerebrovascular injury (TCVI) is an uncommon clinical entity in traumatic brain injury (TBI), yet it may cause devastating brain injury with high morbidity and mortality. Early recognition and prioritized strategic treatment are of paramount importance. A total of 1966 TBI patients admitted between 1999 and 2015 in our tertiary critical care center were reviewed. Screening of TCVI was based on the Guidelines for the Management of Severe Head Injury in Japan. TCVI was confirmed in 33 (1.7%) patients; 29 blunt and 4 penetrating injuries. The primary location of the injury included 16 cervical, 6 craniofacial, and 11 intracranial lesions. On arrival, 15 patients presented with hemorrhage, 5 of these arrived in shock status with massive hemorrhage. Ten presented with ischemic symptoms. Sixteen patients underwent surgical or endovascular intervention, 13 of whom required immediate treatment upon arrival. Surgical procedures included clipping or trapping for traumatic aneurysms, superficial temporal artery - middle cerebral artery bypass, carotid endarterectomy, and direct suture of the injured vessels. Endovascular intervention was undertaken in 7 patients; embolization with Gelfoam (Pharmacia and Upjohn Company, Kalamazoo, MI, USA) or coil for 6 hemorrhagic lesions and stent placement for 1 lesion causing ischemia. Patients' outcome assessed by the Glasgow Outcome Scale at 3 months were good recovery in 8, moderate disability in 3, severe disability in 9, persistent vegetative state in 1, and death in 12, respectively. In order to rescue potentially salvageable TCVI patients, neurosurgeons in charge should be aware of TCVI and master basic skills of cerebrovascular surgical and endovascular procedures to utilize in an emergency setting.

  15. A cross flow-through pedicle free latissimus dorsi flap for high voltage electrical burns.

    PubMed

    Gencel, Eyuphan; Eser, Cengiz; Kesiktas, Erol; Tabakan, Ibrahim; Yavuz, Metin

    2016-06-01

    The management of a high voltage electrical injury and lower limb salvage remains a challenging task for plastic surgeons. Reconstruction with flaps is often the only alternative to limb amputation. The purpose of this study was to present a cross flow-through pedicle free latissimus dorsi muscle flap for the salvage of severely traumatized lower limbs perfused by one remaining vessel (a single vessel lower limb) in high voltage electrical injuries. In this retrospective study, between 2000 and 2014, six men underwent cross-leg free Latissimus dorsi muscle flap operations for limb salvage. They had soft tissue lower leg defects due to high voltage electrical injuries. Their medical records were retrospectively reviewed. All had only one artery that perfused the leg. Free pedicled thoracodorsal artery latissimus dorsi flaps were harvested and connected to the contralateral posterior tibial artery. All defects were successfully covered. No flap loss or major amputation occurred during follow-up (mean; 5.9 years). A computerized tomography angiogram showed intact vessel continuity in the recipient vascular system. The patients were able to walk without any apparatus or assistance after long term follow-up. We recommend that the cross flow-through pedicle free muscle flap should be considered as a salvage procedure for single vessel lower extremities resulting from high voltage electrical burns. Extremity perfusion was not compromised by this procedure. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  16. Neurotherapy of Traumatic Brain Injury/Post-Traumatic Stress Symptoms in Vietnam Veterans.

    PubMed

    Nelson, David V; Esty, Mary Lee

    2015-10-01

    Previous report suggested the beneficial effects of an adaptation of the Flexyx Neurotherapy System (FNS) for the amelioration of mixed traumatic brain injury/post-traumatic stress symptoms in veterans of the Afghanistan and Iraq wars. As a novel variant of electroencephalograph biofeedback, FNS falls within the bioenergy domain of complementary and alternative medicine. Rather than learning voluntary control over the production/inhibition of brain wave patterns, FNS involves offsetting stimulation of brain wave activity by means of an external energy source, specifically, the conduction of electromagnetic energy stimulation via the connecting electroencephalograph cables. Essentially, these procedures subliminally induce strategic distortion of ongoing brain wave activity to presumably facilitate resetting of more adaptive patterns of activity. Reported herein are two cases of Vietnam veterans with mixed traumatic brain injury/post-traumatic stress symptoms, each treated with FNS for 25 sessions. Comparisons of pre- and post-treatment questionnaire assessments revealed notable decreases for all symptoms, suggesting improvements across the broad domains of cognition, pain, sleep, fatigue, and mood/emotion, including post-traumatic stress symptoms, as well as for overall activity levels. Findings suggest FNS treatment may be of potential benefit for the partial amelioration of symptoms, even in some individuals for whom symptoms have been present for decades. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  17. NUCLEAR FLASH TYPE STEAM GENERATOR

    DOEpatents

    Johns, F.L.; Gronemeyer, E.C.; Dusbabek, M.R.

    1962-09-01

    A nuclear steam generating apparatus is designed so that steam may be generated from water heated directly by the nuclear heat source. The apparatus comprises a pair of pressure vessels mounted one within the other, the inner vessel containing a nuclear reactor heat source in the lower portion thereof to which water is pumped. A series of small ports are disposed in the upper portion of the inner vessel for jetting heated water under pressure outwardly into the atmosphere within the interior of the outer vessel, at which time part of the jetted water flashes into steam. The invention eliminates the necessity of any intermediate heat transfer medium and components ordinarily required for handling that medium. (AEC)

  18. Assessing the port to port risk of vessel movements vectoring non-indigenous marine species within and across domestic Australian borders.

    PubMed

    Campbell, Marnie L; Hewitt, Chad L

    2011-07-01

    Biofouling of vessels is implicated as a high risk transfer mechanism of non-indigenous marine species (NIMS). Biofouling on international vessels is managed through stringent border control policies, however, domestic biofouling transfers are managed under different policies and legislative arrangements as they cross internal borders. As comprehensive guidelines are developed and increased compliance of international vessels with 'clean hull' expectations increase, vessel movements from port to port will become the focus of biosecurity management. A semi-quantitative port to port biofouling risk assessment is presented that evaluates the presence of known NIMS in the source port and determines the likelihood of transfer based on the NIMS association with biofouling and environmental match between source and receiving ports. This risk assessment method was used to assess the risk profile of a single dredge vessel during three anticipated voyages within Australia, resulting in negligible to low risk outcomes. This finding is contrasted with expectations in the literature, specifically those that suggest slow moving vessels pose a high to extreme risk of transferring NIMS species.

  19. Characteristics of the Traumatic Forensic Cases Admitted To Emergency Department and Errors in the Forensic Report Writing.

    PubMed

    Aktas, Nurettin; Gulacti, Umut; Lok, Ugur; Aydin, İrfan; Borta, Tayfun; Celik, Murat

    2018-01-01

    To identify errors in forensic reports and to describe the characteristics of traumatic medico-legal cases presenting to the emergency department (ED) at a tertiary care hospital. This study is a retrospective cross-sectional study. The study includes cases resulting in a forensic report among all traumatic patients presenting to the ED of Adiyaman University Training and Research Hospital, Adiyaman, Turkey during a 1-year period. We recorded the demographic characteristics of all the cases, time of presentation to the ED, traumatic characteristics of medico-legal cases, forms of suicide attempt, suspected poisonous substance exposure, the result of follow-up and the type of forensic report. A total of 4300 traumatic medico-legal cases were included in the study and 72% of these cases were male. Traumatic medico-legal cases occurred at the greatest frequency in July (10.1%) and 28.9% of all cases occurred in summer. The most frequent causes of traumatic medico-legal cases in the ED were traffic accidents (43.4%), violent crime (30.5%), and suicide attempt (7.2%). The most common method of attempted suicide was drug intake (86.4%). 12.3% of traumatic medico-legal cases were hospitalized and 24.2% of those hospitalized were admitted to the orthopedics service. The most common error in forensic reports was the incomplete recording of the patient's "cooperation" status (82.7%). Additionally, external traumatic lesions were not defined in 62.4% of forensic reports. The majority of traumatic medico-legal cases were male age 18-44 years, the most common source of trauma was traffic accidents and in the summer months. When writing a forensic report, emergency physicians made mistakes in noting physical examination findings and identifying external traumatic lesions. Physicians should make sure that the traumatic medico-legal patients they treat have adequate documentation for reference during legal proceedings. The legal duties and responsibilities of physicians should be emphasized with in-service training.

  20. Glass Membrane For Controlled Diffusion Of Gases

    DOEpatents

    Shelby, James E.; Kenyon, Brian E.

    2001-05-15

    A glass structure for controlled permeability of gases includes a glass vessel. The glass vessel has walls and a hollow center for receiving a gas. The glass vessel contains a metal oxide dopant formed with at least one metal selected from the group consisting of transition metals and rare earth metals for controlling diffusion of the gas through the walls of the glass vessel. The vessel releases the gas through its walls upon exposure to a radiation source.

  1. Automated classification and quantitative analysis of arterial and venous vessels in fundus images

    NASA Astrophysics Data System (ADS)

    Alam, Minhaj; Son, Taeyoon; Toslak, Devrim; Lim, Jennifer I.; Yao, Xincheng

    2018-02-01

    It is known that retinopathies may affect arteries and veins differently. Therefore, reliable differentiation of arteries and veins is essential for computer-aided analysis of fundus images. The purpose of this study is to validate one automated method for robust classification of arteries and veins (A-V) in digital fundus images. We combine optical density ratio (ODR) analysis and blood vessel tracking algorithm to classify arteries and veins. A matched filtering method is used to enhance retinal blood vessels. Bottom hat filtering and global thresholding are used to segment the vessel and skeleton individual blood vessels. The vessel tracking algorithm is used to locate the optic disk and to identify source nodes of blood vessels in optic disk area. Each node can be identified as vein or artery using ODR information. Using the source nodes as starting point, the whole vessel trace is then tracked and classified as vein or artery using vessel curvature and angle information. 50 color fundus images from diabetic retinopathy patients were used to test the algorithm. Sensitivity, specificity, and accuracy metrics were measured to assess the validity of the proposed classification method compared to ground truths created by two independent observers. The algorithm demonstrated 97.52% accuracy in identifying blood vessels as vein or artery. A quantitative analysis upon A-V classification showed that average A-V ratio of width for NPDR subjects with hypertension decreased significantly (43.13%).

  2. Characterisation of interface astroglial scarring in the human brain after blast exposure: a post-mortem case series.

    PubMed

    Shively, Sharon Baughman; Horkayne-Szakaly, Iren; Jones, Robert V; Kelly, James P; Armstrong, Regina C; Perl, Daniel P

    2016-08-01

    No evidence-based guidelines are available for the definitive diagnosis or directed treatment of most blast-associated traumatic brain injuries, partly because the underlying pathology is unknown. Moreover, few neuropathological studies have addressed whether blast exposure produces unique lesions in the human brain, and if those lesions are comparable with impact-induced traumatic brain injury. We aimed to test the hypothesis that blast exposure produces unique patterns of damage, differing from that associated with impact-induced, non-blast traumatic brain injuries. In this post-mortem case series, we investigated several features of traumatic brain injuries, using clinical histopathology techniques and markers, in brain specimens from male military service members with chronic blast exposures and from those who had died shortly after severe blast exposures. We then compared these results with those from brain specimens from male civilian (ie, non-military) cases with no history of blast exposure, including cases with and without chronic impact traumatic brain injuries and cases with chronic exposure to opiates, and analysed the limited associated clinical histories of all cases. Brain specimens had been archived in tissue banks in the USA. We analysed brain specimens from five cases with chronic blast exposure, three cases with acute blast exposure, five cases with chronic impact traumatic brain injury, five cases with exposure to opiates, and three control cases with no known neurological disorders. All five cases with chronic blast exposure showed prominent astroglial scarring that involved the subpial glial plate, penetrating cortical blood vessels, grey-white matter junctions, and structures lining the ventricles; all cases of acute blast exposure showed early astroglial scarring in the same brain regions. All cases of chronic blast exposure had an antemortem diagnosis of post traumatic stress disorder. The civilian cases, with or without history of impact traumatic brain injury or a history of opiate use, did not have any astroglial scarring in the brain regions analysed. The blast exposure cases showed a distinct and previously undescribed pattern of interface astroglial scarring at boundaries between brain parenchyma and fluids, and at junctions between grey and white matter. This distinctive pattern of scarring may indicate specific areas of damage from blast exposure consistent with the general principles of blast biophysics, and further, could account for aspects of the neuropsychiatric clinical sequelae reported. The generalisability of these findings needs to be explored in future studies, as the number of cases, clinical data, and tissue availability were limited. Defense Health Program of the United States Department of Defense. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. 33 CFR 155.1052 - Response plan development and evaluation criteria for vessels carrying group V petroleum oil as a...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Sources of the equipment and supplies necessary to locate, recover, and mitigate such a discharge. (b... salvage company with appropriate expertise and equipment; and (2) A company with vessel firefighting... or operators must identify intended sources of the resources required under paragraph (e) of this...

  4. 46 CFR 54.15-5 - Protective devices (modifies UG-125).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... evaporator or heat exchanger (see § 54.01-10) shall be equipped with protective devices as required by § 54... unexpected source of heat. (d) Where an additional hazard can be created by exposure of a pressure vessel to fire or other unexpected sources of external heat (for example, vessels used to store liquefied...

  5. 46 CFR 54.15-5 - Protective devices (modifies UG-125).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... evaporator or heat exchanger (see § 54.01-10) shall be equipped with protective devices as required by § 54... unexpected source of heat. (d) Where an additional hazard can be created by exposure of a pressure vessel to fire or other unexpected sources of external heat (for example, vessels used to store liquefied...

  6. 46 CFR 54.15-5 - Protective devices (modifies UG-125).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... evaporator or heat exchanger (see § 54.01-10) shall be equipped with protective devices as required by § 54... unexpected source of heat. (d) Where an additional hazard can be created by exposure of a pressure vessel to fire or other unexpected sources of external heat (for example, vessels used to store liquefied...

  7. 77 FR 27189 - Takes of Marine Mammals Incidental to Specified Activities; Low-Energy Marine Geophysical Survey...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-09

    ... issue an IHA. The notice initiated a 30 day public comment period. SIO plans to use one source vessel..., depending on logistics and weather. The survey will involve one source vessel, the Melville. For the seismic... will be acquired using two GI airguns shot simultaneously. Simultaneous shots from both airguns will...

  8. 46 CFR 54.15-5 - Protective devices (modifies UG-125).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... evaporator or heat exchanger (see § 54.01-10) shall be equipped with protective devices as required by § 54... unexpected source of heat. (d) Where an additional hazard can be created by exposure of a pressure vessel to fire or other unexpected sources of external heat (for example, vessels used to store liquefied...

  9. 46 CFR 54.15-5 - Protective devices (modifies UG-125).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... evaporator or heat exchanger (see § 54.01-10) shall be equipped with protective devices as required by § 54... unexpected source of heat. (d) Where an additional hazard can be created by exposure of a pressure vessel to fire or other unexpected sources of external heat (for example, vessels used to store liquefied...

  10. 40 CFR 63.11524 - Am I subject to this subpart?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reaction vessels. (b) The provisions of this subpart apply to each existing and new electrometallurgical... or other reaction vessel on or before September 15, 2008. (2) An electrometallurgical operation affected source is new if you commenced construction or reconstruction of the EAF or other reaction vessel...

  11. Accelerated recovery from acute brain injuries: clinical efficacy of neurotrophic treatment in stroke and traumatic brain injuries.

    PubMed

    Bornstein, N; Poon, W S

    2012-04-01

    Stroke is one of the most devastating vascular diseases in the world as it is responsible for almost five million deaths per year. Almost 90% of all strokes are ischemic and mainly due to atherosclerosis, cardiac embolism and small-vessel disease. Intracerebral or subarachnoid hemorrhage can lead to hemorrhagic stroke, which usually has the poorest prognosis. Cerebrolysin is a peptide preparation which mimics the action of a neurotrophic factor, protecting stroke-injured neurons and promoting neuroplasticity and neurogenesis. Cerebrolysin has been widely studied as a therapeutic tool for both ischemic and hemorrhagic stroke, as well as traumatic brain injury. In ischemic stroke, Cerebrolysin given as an adjuvant therapy to antiplatelet and rheologically active medication resulted in accelerated improvement in global, neurological and motor functions, cognitive performance and activities of daily living. Cerebrolysin was also safe and well tolerated when administered in patients suffering from hemorrhagic stroke. Traumatic brain injury leads to transient or chronic impairments in physical, cognitive, emotional and behavioral functions. This is associated with deficits in the recognition of basic emotions, the capacity to interpret the mental states of others, and executive functioning. Pilot clinical studies with adjuvant Cerebrolysin in the acute and postacute phases of the injury have shown faster recovery, which translates into an earlier onset of rehabilitation and shortened hospitalization time. Copyright 2012 Prous Science, S.A.U. or its licensors. All rights reserved.

  12. Experiences of giving and receiving care in traumatic brain injury: An integrative review.

    PubMed

    Kivunja, Stephen; River, Jo; Gullick, Janice

    2018-04-01

    To synthesise the literature on the experiences of giving or receiving care for traumatic brain injury for people with traumatic brain injury, their family members and nurses in hospital and rehabilitation settings. Traumatic brain injury represents a major source of physical, social and economic burden. In the hospital setting, people with traumatic brain injury feel excluded from decision-making processes and perceive impatient care. Families describe inadequate information and support for psychological distress. Nurses find the care of people with traumatic brain injury challenging particularly when experiencing heavy workloads. To date, a contemporary synthesis of the literature on people with traumatic brain injury, family and nurse experiences of traumatic brain injury care has not been conducted. Integrative literature review. A systematic search strategy guided by the PRISMA statement was conducted in CINAHL, PubMed, Proquest, EMBASE and Google Scholar. Whittemore and Knafl's (Journal of Advanced Nursing, 52, 2005, 546) integrative review framework guided data reduction, data display, data comparison and conclusion verification. Across the three participant categories (people with traumatic brain injury/family members/nurses) and sixteen subcategories, six cross-cutting themes emerged: seeking personhood, navigating challenging behaviour, valuing skills and competence, struggling with changed family responsibilities, maintaining productive partnerships and reflecting on workplace culture. Traumatic brain injury creates changes in physical, cognitive and emotional function that challenge known ways of being in the world for people. This alters relationship dynamics within families and requires a specific skill set among nurses. Recommendations include the following: (i) formal inclusion of people with traumatic brain injury and families in care planning, (ii) routine risk screening for falls and challenging behaviour to ensure that controls are based on accurate assessment, (iii) formal orientation and training for novice nurses in the management of challenging behaviour, (iv) professional case management to guide access to services and funding and (v) personal skill development to optimise family functioning. © 2018 John Wiley & Sons Ltd.

  13. Amateur boxing and risk of chronic traumatic brain injury: systematic review of observational studies

    PubMed Central

    Knowles, Charles H; Whyte, Greg P

    2007-01-01

    Objective To evaluate the risk of chronic traumatic brain injury from amateur boxing. Setting Secondary research performed by combination of sport physicians and clinical academics. Design, data sources, and methods Systematic review of observational studies in which chronic traumatic brain injury was defined as any abnormality on clinical neurological examination, psychometric testing, neuroimaging studies, and electroencephalography. Studies were identified through database (1950 to date) and bibliographic searches without language restrictions. Two reviewers extracted study characteristics, quality, and data, with adherence to a protocol developed from a widely recommended method for systematic review of observational studies (MOOSE). Results 36 papers had relevant extractable data (from a detailed evaluation of 93 studies of 943 identified from the initial search). Quality of evidence was generally poor. The best quality studies were those with a cohort design and those that used psychometric tests. These yielded the most negative results: only four of 17 (24%) better quality studies found any indication of chronic traumatic brain injury in a minority of boxers studied. Conclusion There is no strong evidence to associate chronic traumatic brain injury with amateur boxing. PMID:17916811

  14. Amateur boxing and risk of chronic traumatic brain injury: systematic review of observational studies.

    PubMed

    Loosemore, Mike; Knowles, Charles H; Whyte, Greg P

    2007-10-20

    To evaluate the risk of chronic traumatic brain injury from amateur boxing. Secondary research performed by combination of sport physicians and clinical academics. DESIGN, DATA SOURCES, AND METHODS: Systematic review of observational studies in which chronic traumatic brain injury was defined as any abnormality on clinical neurological examination, psychometric testing, neuroimaging studies, and electroencephalography. Studies were identified through database (1950 to date) and bibliographic searches without language restrictions. Two reviewers extracted study characteristics, quality, and data, with adherence to a protocol developed from a widely recommended method for systematic review of observational studies (MOOSE). 36 papers had relevant extractable data (from a detailed evaluation of 93 studies of 943 identified from the initial search). Quality of evidence was generally poor. The best quality studies were those with a cohort design and those that used psychometric tests. These yielded the most negative results: only four of 17 (24%) better quality studies found any indication of chronic traumatic brain injury in a minority of boxers studied. There is no strong evidence to associate chronic traumatic brain injury with amateur boxing.

  15. Western High-Fat Diet Consumption during Adolescence Increases Susceptibility to Traumatic Stress while Selectively Disrupting Hippocampal and Ventricular Volumes

    PubMed Central

    Kalyan-Masih, Priya; Vega-Torres, Julio David; Haddad, Elizabeth; Rainsbury, Sabrina; Baghchechi, Mohsen

    2016-01-01

    Abstract Psychological trauma and obesity co-occur frequently and have been identified as major risk factors for psychiatric disorders. Surprisingly, preclinical studies examining how obesity disrupts the ability of the brain to cope with psychological trauma are lacking. The objective of this study was to determine whether an obesogenic Western-like high-fat diet (WD) predisposes rats to post-traumatic stress responsivity. Adolescent Lewis rats (postnatal day 28) were fed ad libitum for 8 weeks with either the experimental WD diet (41.4% kcal from fat) or the control diet (16.5% kcal from fat). We modeled psychological trauma by exposing young adult rats to a cat odor threat. The elevated plus maze and the open field test revealed increased psychological trauma-induced anxiety-like behaviors in the rats that consumed the WD when compared with control animals 1 week after undergoing traumatic stress (p < 0.05). Magnetic resonance imaging showed significant hippocampal atrophy (20% reduction) and lateral ventricular enlargement (50% increase) in the animals fed the WD when compared with controls. These volumetric abnormalities were associated with behavioral indices of anxiety, increased leptin and FK506-binding protein 51 (FKBP51) levels, and reduced hippocampal blood vessel density. We found asymmetric structural vulnerabilities to the WD, particularly the ventral and left hippocampus and lateral ventricle. This study highlights how WD consumption during adolescence impacts key substrates implicated in post-traumatic stress disorder. Understanding how consumption of a WD affects the developmental trajectories of the stress neurocircuitry is critical, as stress susceptibility imposes a marked vulnerability to neuropsychiatric disorders. PMID:27844058

  16. Management of traumatic popliteal vascular injuries in a level I trauma center: A 6-year experience.

    PubMed

    Sciarretta, Jason D; Macedo, Francisco Igor B; Otero, Christian A; Figueroa, Jose N; Pizano, Louis R; Namias, Nicholas

    2015-06-01

    Popliteal vascular trauma remains a challenging entity, and carries the greatest risk of limb loss among the lower extremity vascular injuries. Operative management of traumatic popliteal vascular injuries continues to evolve. We aim at describing our experience with such complex injuries, with associated patterns of injury, diagnostic and therapeutic challenges, and outcomes. From January 2006 to September 2011, 191 adult trauma patients presented to an urban level I trauma center in Miami, Florida with traumatic lower extremity vascular injuries. Variables collected included age, gender, mechanism of injury, and clinical status at presentation. Surgical data included vessel injury, technical aspects of repair, associated complications and outcomes. Forty-seven (24.6%) patients were diagnosed with traumatic popliteal vascular injuries. Mean age was 38.1 ± 16.1 years, and the majority of patients were males (43 patients, 91.4%). There were 21 (44.7%) penetrating injuries, and 26 (55.3%) blunt injuries. Vascular repair with saphenous venous interposition graft and PTFE (polytetrafluoroethylene) grafting were performed in 36 (70.7%) and 2 (3.9%) patients, respectively. Blunt popliteal injuries were significantly more associated with major tissue loss, and length of hospital and intensive care unit (ICU) stays. The risk for amputation is increased with longer ICU stays and the use of PTFE grafting for vascular repair. The overall mortality rate in this series was 8.5%. Blunt popliteal vascular injuries are associated with increased morbidity compared to penetrating trauma. Early restoration of blood perfusion, frequent use of interposition grafts with autogenous saphenous vein, and liberal use of fasciotomies play important role to achieve acceptable outcomes. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  17. Sodium leak detection system for liquid metal cooled nuclear reactors

    DOEpatents

    Modarres, Dariush

    1991-01-01

    A light source is projected across the gap between the containment vessel and the reactor vessel. The reflected light is then analyzed with an absorption spectrometer. The presence of any sodium vapor along the optical path results in a change of the optical transmissivity of the media. Since the absorption spectrum of sodium is well known, the light source is chosen such that the sensor is responsive only to the presence of sodium molecules. The optical sensor is designed to be small and require a minimum of amount of change to the reactor containment vessel.

  18. 77 FR 6065 - Takes of Marine Mammals Incidental to Specified Activities; Marine Geophysical Survey in the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... day public comment period. L-DEO plans to use one source vessel, the R/V Marcus G. Langseth (Langseth... (km) 1,511.9 nautical miles [nmi]) of transect lines (including turns) in the study area. The seismic... involve one source vessel, the Langseth. The Langseth will deploy an array of 36 airguns as an energy...

  19. Type and Quantity of Shipborne Garbage at Selected Tropical Beaches

    PubMed Central

    Husain, Mohd-Lokman

    2016-01-01

    Marine debris is widely distributed at the coastal area of the global oceans; however, shipborne garbage source studies are still lacking to document the pollution in Malaysia Territorial Water. Thus, this study has adopted a standard method of beach marine debris survey at five beaches and inspected 115 vessels to assess the type and amount of debris from shipping source stranded on the beach. This study found that vessel visiting Malaysian ports observed the MARPOL 73/78 Annex V requirements; however, identified objects from shipping activity (1.3%; 2 items/km) found on the beaches indicate that there are vessels disposing of garbage illegally at sea. Therefore, there is a need to promote the use of biodegradable material and introduce environmental education to increase awareness on the vessel. PMID:27819020

  20. Type and Quantity of Shipborne Garbage at Selected Tropical Beaches.

    PubMed

    Mobilik, Julyus-Melvin; Ling, Teck-Yee; Husain, Mohd-Lokman; Hassan, Ruhana

    2016-01-01

    Marine debris is widely distributed at the coastal area of the global oceans; however, shipborne garbage source studies are still lacking to document the pollution in Malaysia Territorial Water. Thus, this study has adopted a standard method of beach marine debris survey at five beaches and inspected 115 vessels to assess the type and amount of debris from shipping source stranded on the beach. This study found that vessel visiting Malaysian ports observed the MARPOL 73/78 Annex V requirements; however, identified objects from shipping activity (1.3%; 2 items/km) found on the beaches indicate that there are vessels disposing of garbage illegally at sea. Therefore, there is a need to promote the use of biodegradable material and introduce environmental education to increase awareness on the vessel.

  1. Imprinted Clay Coil Vessels

    ERIC Educational Resources Information Center

    Lohr, Tresa Rae

    2006-01-01

    The author teaches clay vessel construction in the fifth grade, and it is amazing what can be accomplished in one forty-five minute period when the expectations are clarified in the initial lesson. The author introduces clay coil vessels with a discussion of the sources of clay and how clay relates to fifth-grade science curriculum concepts such…

  2. Structure and innervation of the tusk pulp in the African elephant (Loxodonta africana)

    PubMed Central

    Weissengruber, GE; Egerbacher, M; Forstenpointner, G

    2005-01-01

    African elephants (Loxodonta africana) use their tusks for digging, carrying and behavioural display. Their healing ability following traumatic injury is enormous. Pain experience caused by dentin or pulp damage of tusks seems to be negligible in elephants. In this study we examined the pulp tissue and the nerve distribution using histology, electron microscopy and immunhistochemistry. The results demonstrate that the pulp comprises two differently structured regions. Randomly orientated collagen fibres characterize a cone-like part lying rostral to the foramen apicis dentis. Numerous nerve fibres and Ruffini endings are found within this cone. Rostral to the cone, delicate collagen fibres and large vessels are orientated longitudinally. The rostral two-thirds of the pulp are highly vascularized, whereas nerve fibres are sparse. Vessel and nerve fibre distribution and the structure of connective tissue possibly play important roles in healing and in the obviously limited pain experience after tusk injuries and pulp alteration. The presence of Ruffini endings is most likely related to the use of tusks as tools. PMID:15817106

  3. Convexity Subarachnoid Hemorrhage Due to Cardioembolic Stroke in a Woman with Thyrotoxicosis: Α Case Report.

    PubMed

    Spanou, Ioanna; Vassilopoulou, Sophia; Koroboki, Eleni; Tountopoulou, Argyro; Velonakis, Georgios; Mitsikostas, Dimos Dimitrios

    2017-10-01

    Non-traumatic convexity subarachnoid hemorrhage (cSAH) is a rarely reported condition with a wide spectrum of etiologies. Cerebral ischemia secondary to extracranial or intracranial atherosclerotic disease has been identified as a relatively uncommon cause of cSAH. We report a case of cSAH caused by cardioembolic stroke. A 69-year old female patient developed suddenly left-sided face and body weakness and numbness and visual neglect on the left. She was newly detected with paroxysmal atrial fibrillation on the ground of thyrotoxicosis. Brain magnetic resonance imaging revealed ischemia of embolic pattern with cSAH. Further evaluation excluded other cause of hemorrhage. Dilation of leptomeningeal collateral vessels and rupture of pial vessels in distal cortical arteries may caused cSAH. Full anticoagulation was initiated. After one month, her condition improved significantly (NIHSS from 6 to 2). cSAH may be a rare complication of cardioembolic stroke. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. The burden of traumatic brain injury among adolescent and young adult workers in Washington State.

    PubMed

    Graves, Janessa M; Sears, Jeanne M; Vavilala, Monica S; Rivara, Frederick P

    2013-06-01

    This study describes injury characteristics and costs of work-related traumatic brain injury (WRTBI) among 16-24 year olds in Washington State between 1998 and 2008. WRTBIs were identified in the Washington Trauma Registry (WTR) and linked to workers' compensation (WC) claims data. Medical and time-loss compensation costs were compared between workers with isolated TBI and TBI with other trauma. Of 273 WRTBI cases identified, most (61.5%) were TBI with other trauma. One-third of WRTBI did not link to a WC claim. Medical costs averaged $88,307 (median $16,426) for isolated TBI cases, compared to $73,669 (median $41,167) for TBI with other trauma. Results highlight the financial impact of WRTBI among young workers. Multiple data sources provided a more comprehensive picture than a single data source alone. This linked-data approach holds great potential for future traumatic occupational injury research. TBI among young workers not only involves long-term health and psychological impacts, but is costly as well. Copyright © 2013 National Safety Council and Elsevier Ltd. All rights reserved.

  5. Preliminary evidence for a unique role of disgust-based conditioning in posttraumatic stress.

    PubMed

    Badour, Christal L; Feldner, Matthew T; Blumenthal, Heidemarie; Knapp, Ashley

    2013-04-01

    Independent lines of evidence have linked posttraumatic stress symptomatology to both peritraumatic disgust (i.e., disgust experienced during a traumatic event) and posttraumatic disgust reactivity in response to traumatic event cues among individuals exposed to traumatic events. Much of this work suggests disgust, defined as a rejection/revulsion response aimed at distancing oneself from a potential source of contamination, may be important in understanding the nature of posttraumatic stress reactions even after accounting for the more frequently studied affective states of fear and anxiety. The current investigation provided a preliminary test of a model of disgust in posttraumatic stress among a sample of 54 community-recruited women with a history sexual victimization. Both peritraumatic disgust (r = .31) and posttraumatic disgust reactivity (r = .42) in response to an idiographic traumatic event script were significantly associated with posttraumatic stress symptom severity. After accounting for variability-associated peritraumatic fear and posttraumatic anxious reactivity, an indirect effect of peritraumatic disgust through posttraumatic disgust reactivity also was found, suggesting that one mechanism through which peritraumatic disgust relates to posttraumatic stress is through its relation with increased posttraumatic disgust reactivity. These findings highlight the importance of further elucidating the nature of disgust in relation to traumatic events and subsequent posttraumatic stress reactions. Copyright © 2013 International Society for Traumatic Stress Studies.

  6. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  7. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  8. 40 CFR 63.11140 - Am I subject to this subpart?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...

  9. Griffonia simplicifolia Isolectin B4 Identifies a Specific Subpopulation of Angiogenic Blood Vessels Following Contusive Spinal Cord Injury in the Adult Mouse

    PubMed Central

    BENTON, RICHARD L.; MADDIE, MELISSA A.; MINNILLO, DANIELLE R.; HAGG, THEO; WHITTEMORE, SCOTT R.

    2009-01-01

    After traumatic spinal cord injury (SCI), disruption and plasticity of the microvasculature within injured spinal tissue contribute to the pathological cascades associated with the evolution of both primary and secondary injury. Conversely, preserved vascular function most likely results in tissue sparing and subsequent functional recovery. It has been difficult to identify subclasses of damaged or regenerating blood vessels at the cellular level. Here, adult mice received a single intravenous injection of the Griffonia simplicifolia isolectin B4 (IB4) at 1–28 days following a moderate thoracic (T9) contusion. Vascular binding of IB4 was maximally observed 7 days following injury, a time associated with multiple pathologic aspects of the intrinsic adaptive angiogenesis, with numbers of IB4 vascular profiles decreasing by 21 days postinjury. Quantitative assessment of IB4 binding shows that it occurs within the evolving lesion epicenter, with affected vessels expressing a temporally specific dysfunctional tight junctional phenotype as assessed by occludin, claudin-5, and ZO-1 immunoreactivities. Taken together, these results demonstrate that intravascular lectin delivery following SCI is a useful approach not only for observing the functional status of neovascular formation but also for definitively identifying specific subpopulations of reactive spinal microvascular elements. PMID:18092342

  10. Cerebral microbleed detection in traumatic brain injury patients using 3D convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Standvoss, K.; Crijns, T.; Goerke, L.; Janssen, D.; Kern, S.; van Niedek, T.; van Vugt, J.; Alfonso Burgos, N.; Gerritse, E. J.; Mol, J.; van de Vooren, D.; Ghafoorian, M.; van den Heuvel, T. L. A.; Manniesing, R.

    2018-02-01

    The number and location of cerebral microbleeds (CMBs) in patients with traumatic brain injury (TBI) is important to determine the severity of trauma and may hold prognostic value for patient outcome. However, manual assessment is subjective and time-consuming due to the resemblance of CMBs to blood vessels, the possible presence of imaging artifacts, and the typical heterogeneity of trauma imaging data. In this work, we present a computer aided detection system based on 3D convolutional neural networks for detecting CMBs in 3D susceptibility weighted images. Network architectures with varying depth were evaluated. Data augmentation techniques were employed to improve the networks' generalization ability and selective sampling was implemented to handle class imbalance. The predictions of the models were clustered using a connected component analysis. The system was trained on ten annotated scans and evaluated on an independent test set of eight scans. Despite this limited data set, the system reached a sensitivity of 0.87 at 16.75 false positives per scan (2.5 false positives per CMB), outperforming related work on CMB detection in TBI patients.

  11. Gold nanoparticle induced vasculature damage in radiotherapy: Comparing protons, megavoltage photons, and kilovoltage photons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Yuting, E-mail: yutingl188@gmail.com; Paganetti, Harald; Schuemann, Jan

    2015-10-15

    Purpose: The purpose of this work is to investigate the radiosensitizing effect of gold nanoparticle (GNP) induced vasculature damage for proton, megavoltage (MV) photon, and kilovoltage (kV) photon irradiation. Methods: Monte Carlo simulations were carried out using tool for particle simulation (TOPAS) to obtain the spatial dose distribution in close proximity up to 20 μm from the GNPs. The spatial dose distribution from GNPs was used as an input to calculate the dose deposited to the blood vessels. GNP induced vasculature damage was evaluated for three particle sources (a clinical spread out Bragg peak proton beam, a 6 MV photonmore » beam, and two kV photon beams). For each particle source, various depths in tissue, GNP sizes (2, 10, and 20 nm diameter), and vessel diameters (8, 14, and 20 μm) were investigated. Two GNP distributions in lumen were considered, either homogeneously distributed in the vessel or attached to the inner wall of the vessel. Doses of 30 Gy and 2 Gy were considered, representing typical in vivo enhancement studies and conventional clinical fractionation, respectively. Results: These simulations showed that for 20 Au-mg/g GNP blood concentration homogeneously distributed in the vessel, the additional dose at the inner vascular wall encircling the lumen was 43% of the prescribed dose at the depth of treatment for the 250 kVp photon source, 1% for the 6 MV photon source, and 0.1% for the proton beam. For kV photons, GNPs caused 15% more dose in the vascular wall for 150 kVp source than for 250 kVp. For 6 MV photons, GNPs caused 0.2% more dose in the vascular wall at 20 cm depth in water as compared to at depth of maximum dose (Dmax). For proton therapy, GNPs caused the same dose in the vascular wall for all depths across the spread out Bragg peak with 12.7 cm range and 7 cm modulation. For the same weight of GNPs in the vessel, 2 nm diameter GNPs caused three times more damage to the vessel than 20 nm diameter GNPs. When the GNPs were attached to the inner vascular wall, the damage to the inner vascular wall can be up to 207% of the prescribed dose for the 250 kVp photon source, 4% for the 6 MV photon source, and 2% for the proton beam. Even though the average dose increase from the proton beam and MV photon beam was not large, there were high dose spikes that elevate the local dose of the parts of the blood vessel to be higher than 15 Gy even for 2 Gy prescribed dose, especially when the GNPs can be actively targeted to the endothelial cells. Conclusions: GNPs can potentially be used to enhance radiation therapy by causing vasculature damage through high dose spikes caused by the addition of GNPs especially for hypofractionated treatment. If GNPs are designed to actively accumulate at the tumor vasculature walls, vasculature damage can be increased significantly. The largest enhancement is seen using kilovoltage photons due to the photoelectric effect. Although no significant average dose enhancement was observed for the whole vasculature structure for both MV photons and protons, they can cause high local dose escalation (>15 Gy) to areas of the blood vessel that can potentially contribute to the disruption of the functionality of the blood vessels in the tumor.« less

  12. Gold nanoparticle induced vasculature damage in radiotherapy: Comparing protons, megavoltage photons, and kilovoltage photons.

    PubMed

    Lin, Yuting; Paganetti, Harald; McMahon, Stephen J; Schuemann, Jan

    2015-10-01

    The purpose of this work is to investigate the radiosensitizing effect of gold nanoparticle (GNP) induced vasculature damage for proton, megavoltage (MV) photon, and kilovoltage (kV) photon irradiation. Monte Carlo simulations were carried out using tool for particle simulation (TOPAS) to obtain the spatial dose distribution in close proximity up to 20 μm from the GNPs. The spatial dose distribution from GNPs was used as an input to calculate the dose deposited to the blood vessels. GNP induced vasculature damage was evaluated for three particle sources (a clinical spread out Bragg peak proton beam, a 6 MV photon beam, and two kV photon beams). For each particle source, various depths in tissue, GNP sizes (2, 10, and 20 nm diameter), and vessel diameters (8, 14, and 20 μm) were investigated. Two GNP distributions in lumen were considered, either homogeneously distributed in the vessel or attached to the inner wall of the vessel. Doses of 30 Gy and 2 Gy were considered, representing typical in vivo enhancement studies and conventional clinical fractionation, respectively. These simulations showed that for 20 Au-mg/g GNP blood concentration homogeneously distributed in the vessel, the additional dose at the inner vascular wall encircling the lumen was 43% of the prescribed dose at the depth of treatment for the 250 kVp photon source, 1% for the 6 MV photon source, and 0.1% for the proton beam. For kV photons, GNPs caused 15% more dose in the vascular wall for 150 kVp source than for 250 kVp. For 6 MV photons, GNPs caused 0.2% more dose in the vascular wall at 20 cm depth in water as compared to at depth of maximum dose (Dmax). For proton therapy, GNPs caused the same dose in the vascular wall for all depths across the spread out Bragg peak with 12.7 cm range and 7 cm modulation. For the same weight of GNPs in the vessel, 2 nm diameter GNPs caused three times more damage to the vessel than 20 nm diameter GNPs. When the GNPs were attached to the inner vascular wall, the damage to the inner vascular wall can be up to 207% of the prescribed dose for the 250 kVp photon source, 4% for the 6 MV photon source, and 2% for the proton beam. Even though the average dose increase from the proton beam and MV photon beam was not large, there were high dose spikes that elevate the local dose of the parts of the blood vessel to be higher than 15 Gy even for 2 Gy prescribed dose, especially when the GNPs can be actively targeted to the endothelial cells. GNPs can potentially be used to enhance radiation therapy by causing vasculature damage through high dose spikes caused by the addition of GNPs especially for hypofractionated treatment. If GNPs are designed to actively accumulate at the tumor vasculature walls, vasculature damage can be increased significantly. The largest enhancement is seen using kilovoltage photons due to the photoelectric effect. Although no significant average dose enhancement was observed for the whole vasculature structure for both MV photons and protons, they can cause high local dose escalation (>15 Gy) to areas of the blood vessel that can potentially contribute to the disruption of the functionality of the blood vessels in the tumor.

  13. Gold nanoparticle induced vasculature damage in radiotherapy: Comparing protons, megavoltage photons, and kilovoltage photons

    PubMed Central

    Lin, Yuting; Paganetti, Harald; McMahon, Stephen J.; Schuemann, Jan

    2015-01-01

    Purpose: The purpose of this work is to investigate the radiosensitizing effect of gold nanoparticle (GNP) induced vasculature damage for proton, megavoltage (MV) photon, and kilovoltage (kV) photon irradiation. Methods: Monte Carlo simulations were carried out using tool for particle simulation (TOPAS) to obtain the spatial dose distribution in close proximity up to 20 μm from the GNPs. The spatial dose distribution from GNPs was used as an input to calculate the dose deposited to the blood vessels. GNP induced vasculature damage was evaluated for three particle sources (a clinical spread out Bragg peak proton beam, a 6 MV photon beam, and two kV photon beams). For each particle source, various depths in tissue, GNP sizes (2, 10, and 20 nm diameter), and vessel diameters (8, 14, and 20 μm) were investigated. Two GNP distributions in lumen were considered, either homogeneously distributed in the vessel or attached to the inner wall of the vessel. Doses of 30 Gy and 2 Gy were considered, representing typical in vivo enhancement studies and conventional clinical fractionation, respectively. Results: These simulations showed that for 20 Au-mg/g GNP blood concentration homogeneously distributed in the vessel, the additional dose at the inner vascular wall encircling the lumen was 43% of the prescribed dose at the depth of treatment for the 250 kVp photon source, 1% for the 6 MV photon source, and 0.1% for the proton beam. For kV photons, GNPs caused 15% more dose in the vascular wall for 150 kVp source than for 250 kVp. For 6 MV photons, GNPs caused 0.2% more dose in the vascular wall at 20 cm depth in water as compared to at depth of maximum dose (Dmax). For proton therapy, GNPs caused the same dose in the vascular wall for all depths across the spread out Bragg peak with 12.7 cm range and 7 cm modulation. For the same weight of GNPs in the vessel, 2 nm diameter GNPs caused three times more damage to the vessel than 20 nm diameter GNPs. When the GNPs were attached to the inner vascular wall, the damage to the inner vascular wall can be up to 207% of the prescribed dose for the 250 kVp photon source, 4% for the 6 MV photon source, and 2% for the proton beam. Even though the average dose increase from the proton beam and MV photon beam was not large, there were high dose spikes that elevate the local dose of the parts of the blood vessel to be higher than 15 Gy even for 2 Gy prescribed dose, especially when the GNPs can be actively targeted to the endothelial cells. Conclusions: GNPs can potentially be used to enhance radiation therapy by causing vasculature damage through high dose spikes caused by the addition of GNPs especially for hypofractionated treatment. If GNPs are designed to actively accumulate at the tumor vasculature walls, vasculature damage can be increased significantly. The largest enhancement is seen using kilovoltage photons due to the photoelectric effect. Although no significant average dose enhancement was observed for the whole vasculature structure for both MV photons and protons, they can cause high local dose escalation (>15 Gy) to areas of the blood vessel that can potentially contribute to the disruption of the functionality of the blood vessels in the tumor. PMID:26429263

  14. Delayed-onset post-traumatic headache after a motor vehicle collision: a case report

    PubMed Central

    Stupar, Maja; Kim, Peter SY

    2007-01-01

    Introduction Headaches are common after a motor vehicle accident (MVA). Post-traumatic headaches share many clinical symptoms including the clinical course of primary headaches. Secondary headaches (including those resulting from a subdural hematoma) are not as common, but should be considered in cases of post-traumatic events particularly if clinical symptoms progress. Clinical Features A case of a patient with a post-traumatic subdural hematoma demonstrates the importance of carefully examining, properly diagnosing and managing patients that experience headaches after MVAs. This patient presented with uncomplicated low back pain, neck pain and headache which progressed at one month to include focal neurological deficits. Since clinical examination alone may not be sufficient to diagnose secondary headaches, immediate referral to the emergency department may be required. Conclusion Primary contact practitioners should be aware of the various causes of headaches that result after a MVA. Headaches, which do not respond or progress, should be followed aggressively to determine their source. PMID:17657301

  15. Alpine ski and snowboarding traumatic injuries: incidence, injury patterns, and risk factors for 10 years.

    PubMed

    McBeth, Paul B; Ball, Chad G; Mulloy, Robert H; Kirkpatrick, Andrew W

    2009-05-01

    Alpine skiing and snowboarding are popular winter sports in Canada. Every year participation in these activities results in traumatic injury. The purpose of this study was to identify the incidence and injury patterns, as well as risk factors associated with ski and snowboarding injuries. A comprehensive 10-year retrospective review of Alpine ski and snowboarding injuries from 1996 to 2006 was conducted. The Alberta Trauma Registry was used as the primary source of data. A total of 196 patients (56.6% skiers, 43.4% snowboarders) were identified as having major traumatic injuries (Injury Severity Score, >or=12). Forty-three patients required intensive care unit support. The majority of injuries were related to falls and collisions with natural objects. Head injuries were most common, followed by chest, spinal, and extremity trauma. Seventy-nine patients required emergency surgery. Skiing and snowboarding represent activities with high potential for traumatic injury. Safety initiatives should be developed to target this population.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Chuanfu; Kresin, Vitaly V., E-mail: kresin@usc.edu

    This note describes a system for transferring a load of high purity lithium metal into a molecular or cluster beam source. A hot loading vessel is thoroughly baked out while empty and overpressured with argon. A clean Li rod is then dropped in through a long narrow tube. The thoroughly degassed interior of the vessel and the rapid melting of the inserted rod facilitate contamination-free transfer of the highly reactive liquid metal into the source oven.

  17. 46 CFR 295.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... between two or more ports and/or points in the United States. (l) Eligible Vessel, means a vessel that... sources with a minimum speed of 12 knots. (2) Dry Cargo—All dry cargo ships, including integrated tug...

  18. Induction of Pancreatic Differentiation by Signals from Blood Vessels

    NASA Astrophysics Data System (ADS)

    Lammert, Eckhard; Cleaver, Ondine; Melton, Douglas

    2001-10-01

    Blood vessels supply developing organs with metabolic sustenance. Here, we demonstrate a role for blood vessels as a source of developmental signals during pancreatic organogenesis. In vitro experiments with embryonic mouse tissues demonstrate that blood vessel endothelium induces insulin expression in isolated endoderm. Removal of the dorsal aorta in Xenopus laevis embryos results in the failure of insulin expression in vivo. Furthermore, using transgenic mice, we show that ectopic vascularization in the posterior foregut leads to ectopic insulin expression and islet hyperplasia. These results indicate that vessels not only provide metabolic sustenance, but also provide inductive signals for organ development.

  19. Workplace bullying and post-traumatic stress symptoms among family physicians in Lithuania: an occupation and region specific approach.

    PubMed

    Malinauskiene, Vilija; Einarsen, Staale

    2014-12-01

    The study investigated associations between workplace bullying and post-traumatic stress symptoms as compared to and controlled for associations between the latter and other psychosocial stress factors at work and in everyday life. The study employed a representative sample of Lithuanian family physicians, hence investigated a particularly resourceful occupational group in a geographical region earlier found to have a high risk context for exposure to bullying at work. With a response rate of 89.2%, a total of 323 family physicians filled in an anonymous questionnaire on workplace bullying, post-traumatic symptomatology (IES-R), other psychosocial stressors at work and in everyday life, personal health resources (sense of coherence), behavioral characteristics and demographic variables. The statistical software SPSS 14.0, Windows was used in the analysis. Associations were tested using a multivariate logistic regression analysis. A high prevalence of bullying was found among family physicians in Lithuania, with 13% of them experiencing severe workplace bullying and 17.3% experiencing more occasional incidents of bullying. The prevalence of post-traumatic stress symptoms was also high with 15.8% scoring above the standardized cut-off thresholds for post-traumatic stress disorder. The odds ratio (OR) of severe bullying for post-traumatic stress after adjustment for age and gender was 8.05 (95% confidence intervals (CI): 3.80-17.04). In the fully adjusted model it increased to 13.88 (95% CI: 4.68-41.13) indicating cumulative effects of all the investigated stressors. Workplace bullying is particularly prevalent among Lithuanian family physicians, as are the symptoms of post-traumatic distress. Strong associations between post-traumatic stress and exposure to severe bullying indicate that bullying is a significant source of mental health.

  20. Reactor vessel using metal oxide ceramic membranes

    DOEpatents

    Anderson, Marc A.; Zeltner, Walter A.

    1992-08-11

    A reaction vessel for use in photoelectrochemical reactions includes as its reactive surface a metal oxide porous ceramic membrane of a catalytic metal such as titanium. The reaction vessel includes a light source and a counter electrode. A provision for applying an electrical bias between the membrane and the counter electrode permits the Fermi levels of potential reaction to be favored so that certain reactions may be favored in the vessel. The electrical biasing is also useful for the cleaning of the catalytic membrane.

  1. 40 CFR Table 4 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Group 1 Storage Vessels at New Affected... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 4 Table 4 to Subpart JJJ of Part 63—Group 1 Storage Vessels at New Affected...

  2. 40 CFR Table 4 to Subpart Jjj of... - Group 1 Storage Vessels at New Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 12 2012-07-01 2011-07-01 true Group 1 Storage Vessels at New Affected... CATEGORIES National Emission Standards for Hazardous Air Pollutant Emissions: Group IV Polymers and Resins Pt. 63, Subpt. JJJ, Table 4 Table 4 to Subpart JJJ of Part 63—Group 1 Storage Vessels at New Affected...

  3. 46 CFR 32.60-45 - Segregation of spaces containing the emergency source of electric power-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... electric power-TB/ALL. 32.60-45 Section 32.60-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed... power—TB/ALL. (a) The provisions of this section shall apply to all vessels contracted for on or after...

  4. 46 CFR 32.60-45 - Segregation of spaces containing the emergency source of electric power-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... electric power-TB/ALL. 32.60-45 Section 32.60-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed... power—TB/ALL. (a) The provisions of this section shall apply to all vessels contracted for on or after...

  5. 46 CFR 32.60-45 - Segregation of spaces containing the emergency source of electric power-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... electric power-TB/ALL. 32.60-45 Section 32.60-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Hull Requirements for Tank Vessels Constructed... power—TB/ALL. (a) The provisions of this section shall apply to all vessels contracted for on or after...

  6. In-situ structural integrity evaluation for high-power pulsed spallation neutron source - Effects of cavitation damage on structural vibration

    NASA Astrophysics Data System (ADS)

    Wan, Tao; Naoe, Takashi; Futakawa, Masatoshi

    2016-01-01

    A double-wall structure mercury target will be installed at the high-power pulsed spallation neutron source in the Japan Proton Accelerator Research Complex (J-PARC). Cavitation damage on the inner wall is an important factor governing the lifetime of the target-vessel. To monitor the structural integrity of the target vessel, displacement velocity at a point on the outer surface of the target vessel is measured using a laser Doppler vibrometer (LDV). The measured signals can be used for evaluating the damage inside the target vessel because of cyclic loading and cavitation bubble collapse caused by pulsed-beam induced pressure waves. The wavelet differential analysis (WDA) was applied to reveal the effects of the damage on vibrational cycling. To reduce the effects of noise superimposed on the vibration signals on the WDA results, analysis of variance (ANOVA) and analysis of covariance (ANCOVA), statistical methods were applied. Results from laboratory experiments, numerical simulation results with random noise added, and target vessel field data were analyzed by the WDA and the statistical methods. The analyses demonstrated that the established in-situ diagnostic technique can be used to effectively evaluate the structural response of the target vessel.

  7. VEGI attenuates the inflammatory injury and disruption of blood-brain barrier partly by suppressing the TLR4/NF-κB signaling pathway in experimental traumatic brain injury.

    PubMed

    Gao, Weiwei; Zhao, Zilong; Yu, Gongjie; Zhou, Ziwei; Zhou, Yuan; Hu, Tingting; Jiang, Rongcai; Zhang, Jianning

    2015-10-05

    Acute traumatic brain injury (TBI) tends to cause the over-activation of inflammatory response and disruption of blood brain barrier (BBB), associating with long-term cognitive and behavioral dysfunction. Vascular endothelial growth inhibitor (VEGI), as a suppressor in the angiogenesis specifically by inducing apoptosis in proliferating endothelial cells, has been applied to different diseases, especially the tumors. But rare study had been done in the field of brain injury. So in this study, we investigated the effects and mechanisms associated with VEGI-induced neuroprotection following CNS injury in mice TBI models. We demonstrated that the VEGI treatment reduced the contusion brain tissue loss, the permeation of inflammatory cells (MPO(+)) and the activation of microglia (Iba-1(+)). The treatment up-regulated the tight junction proteins (CLN5, ZO-1 and OCLN), which are vital importance for the integrity of the blood brain barrier (BBB), the B-cell lymphoma 2 (Bcl-2) cell survival factors, while down-regulated the expression of TLR4, NF-κB and inflammatory cytokines (IL-1β, TNF-α, iNOS). The treatment also decreased the expression of reactive astrocytes (GFAP(+)), as well as the VEGF, and lowered the permeability of Evens Blue (EB). These findings suggested that the VEGI-treatment could alleviate the post-traumatic excessive inflammatory response, and maintain the stability of blood vessels, remitting the secondary brain damage. Copyright © 2015. Published by Elsevier B.V.

  8. Secondary abdominal compartment syndrome after complicated traumatic lower extremity vascular injuries.

    PubMed

    Macedo, F I B; Sciarretta, J D; Otero, C A; Ruiz, G; Ebler, D J; Pizano, L R; Namias, N

    2016-04-01

    Secondary abdominal compartment syndrome (ACS) can occur in trauma patients without abdominal injuries. Surgical management of patients presenting with secondary ACS after isolated traumatic lower extremity vascular injury (LEVI) continues to evolve, and associated outcomes remain unknown. From January 2006 to September 2011, 191 adult trauma patients presented to the Ryder Trauma Center, an urban level I trauma center in Miami, Florida with traumatic LEVIs. Among them 10 (5.2 %) patients were diagnosed with secondary ACS. Variables collected included age, gender, mechanism of injury, and clinical status at presentation. Surgical data included vessel injury, technical aspects of repair, associated complications, and outcomes. Mean age was 37.4 ± 18.0 years (range 16-66 years), and the majority of patients were males (8 patients, 80 %). There were 7 (70 %) penetrating injuries (5 gunshot wounds and 2 stab wounds), and 3 blunt injuries with mean Injury Severity Score (ISS) 21.9 ± 14.3 (range 9-50). Surgical management of LEVIs included ligation (4 patients, 40 %), primary repair (1 patient, 10 %), reverse saphenous vein graft (2 patients, 20 %), and PTFE interposition grafting (3 patients, 30 %). The overall mortality rate in this series was 60 %. The association between secondary ACS and lower extremity vascular injuries carries high morbidity and mortality rates. Further research efforts should focus at identifying parameters to accurately determine resuscitation goals, and therefore, prevent such a devastating condition.

  9. Narratives from caregivers of children surviving the terrorist attack in Beslan: issues of health, culture, and resilience.

    PubMed

    Moscardino, Ughetta; Axia, Giovanna; Scrimin, Sara; Capello, Fabia

    2007-04-01

    Acts of terrorism have an extremely negative impact on the mental health of children and families. The school siege in Beslan, Russia, in 2004, represents a particularly traumatizing event as it was directed specifically at children and involved the entire community. This qualitative study aims to: (a) examine caregiver reactions to the terrorist attack in Beslan as reported 3 months after the traumatic event; (b) determine the extent to which indigenous cultural values and religious belief systems play a role in Beslan's caregivers' reactions to such event; and (c) identify variables that may function as sources of resilience to caregivers. A convenience sample of 17 primary caregivers from Beslan with at least one child who survived the school siege were asked to participate in semi-structured interviews. Narratives generated from the interviews were qualitatively analyzed using a thematic approach; nine major themes were identified. Caregivers' concerns centered on children's physical and psychological well-being, the reorganization of family life, and the disruption of community ties. Cultural values of pride, heroism, courage, and revenge emerged as relevant aspects shaping caregivers' reactions to the traumatic event. Possible sources of resilience included the willingness to return to normality, social support, and the reaffirmation of positive, culturally shared values in face of the perceived threat of future terrorist attacks. Findings are discussed in terms of their theoretical implications on the effects of trauma on children and families as well as interventions with highly traumatized populations in diverse cultural settings.

  10. Neurogenic Fever.

    PubMed

    Meier, Kevin; Lee, Kiwon

    2017-02-01

    Fever is a relatively common occurrence among patients in the intensive care setting. Although the most obvious and concerning etiology is sepsis, drug reactions, venous thromboembolism, and postsurgical fevers are all on the differential diagnosis. There is abundant evidence that fever is detrimental in acute neurologic injury. Worse outcomes are reported in acute stroke, subarachnoid hemorrhage, and traumatic brain injury. In addition to the various etiologies of fever in the intensive care setting, neurologic illness is a risk factor for neurogenic fevers. This primarily occurs in subarachnoid hemorrhage and traumatic brain injury, with hypothalamic injury being the proposed mechanism. Paroxysmal sympathetic hyperactivity is another source of hyperthermia commonly seen in the population with traumatic brain injury. This review focuses on the detrimental effects of fever on the neurologically injured as well as the risk factors and diagnosis of neurogenic fever.

  11. Alveolar hemorrhage in a case of fat embolism syndrome: A case report with short systemic review.

    PubMed

    Dash, Sananta Kumar; Bansal, Avdesh; Wankhade, Bhushan Sudhakar; Sharma, Rakesh

    2013-04-01

    Fat embolism and fat embolism syndrome (FES) are well-known complications of long bone fracture and surgery involving manipulation of skeletal elements. Many non-traumatic causes of FES have been suggested but they constitute only a small portion. FES presents with classical symptoms of petechiae, hypoxemia, central nervous system symptoms along with other features such as tachycardia and pyrexia. Diagnosis of FES relies on clinical judgment rather than objective findings such as emboli present in the retinal vessels on fundoscopy, fat globules present in urine and sputum, a sudden inexplicable drop in hematocrit or platelet values, increasing erythrocyte sedimentation rate.

  12. Acute Management of the Traumatically Injured Pelvis.

    PubMed

    Skitch, Steven; Engels, Paul T

    2018-02-01

    Severe pelvic trauma is a challenging condition. The pelvis can create multifocal hemorrhage that is not easily compressible nor managed by traditional surgical methods such as tying off a blood vessel or removing an organ. Its treatment often requires reapproximation of bony structures, damage control resuscitation, assessment for associated injuries, and triage of investigations, as well as multimodality hemorrhage control (external fixation, preperitoneal packing, angioembolization, REBOA [resuscitative endovascular balloon occlusion of the aorta]) by multidisciplinary trauma specialists (general surgeons, orthopedic surgeons, endovascular surgeons/interventional radiologists). This article explores this complex clinical problem and provides a practical approach to its management. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Position indicator

    DOEpatents

    Tanner, David E.

    1981-01-01

    A nuclear reactor system is described in which a position indicator is provided for detecting and indicating the position of a movable element inside a pressure vessel. The movable element may be a valve element or similar device which moves about an axis. Light from a light source is transmitted from a source outside the pressure vessel to a first region inside the pressure vessel in alignment with the axis of the movable element. The light is redirected by a reflector prism to a second region displaced radially from the first region. The reflector prism moves in response to movement of the movable element about its axis such that the second region moves arcuately with respect to the first region. Sensors are arrayed in an arc corresponding to the arc of movement of the second region and signals are transmitted from the sensors to the exterior of the reactor vessel to provide indication of the position of the movable element.

  14. Use of giant-sized flow-through venous flap for simultaneous reconstruction of dual or multiple major arteries in salvage therapy for complex upper limb traumatic injury.

    PubMed

    Zheng, Da-Wei; Li, Zhang-Can; Shi, Rong-Jian; Sun, Feng; Xu, Li; Shou, Kui-Shui

    2016-02-01

    Salvage repair after complex upper limb traumatic injury is surgically challenging due to underlying major arterial impairment with complicating a large-sized soft tissue defect. The purpose of this study was to evaluate the effectiveness and safety of using a giant-sized (≥100 cm(2)) flow-through venous flap for reconstruction of dual or multiple forearm, metacarpal, or digital arteries after complex upper limb traumatic injury. Seven patients were consecutively hospitalized for emergency salvage repair after complex upper limb traumatic injury between March 2012 and May 2014. The forearm and palmar artery defects were repaired using the calf great saphenous vein flap and the volar forearm venous flap, respectively. The flow-through venous flap ranged from 9.5 cm × 12.0 cm to 12.0 cm × 20.0 cm (mean, 158.4 cm(2)) in size. The flaps and affected limbs survived uneventfully in five patients, with one patient experiencing distal flap marginal necrosis and a second patient requiring amputation of the affected limb. Computed tomography angiography showed patent vessels in all patients. The mean total active motion of the repaired fingers was 199.5° versus 258.8° for the contralateral counterpart (77.1%). The sensory return was determined to be S2 in 2 patients, S3 in 3 patients and S3+ in 1 patient. The disability scores for the arm, shoulder, and hand ranged from 4.6-18.2 (mean, 11.3), and the mean Michigan hand outcomes questionnaire score was 7.8 ± 0.9. The flow-through venous flap is an effective and safe treatment alternative for salvage therapy of a ≥100-cm(2) complex upper limb traumatic injury with dual or multiple major arterial impairment. This technique allows simultaneous reconstruction of dual or multiple artery injuries and an extensive soft tissue defect. Serious surgical site infection remains a major safety concern and necessitates radical debridement in complicating cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Thin films of mixed metal compounds

    DOEpatents

    Mickelsen, R.A.; Chen, W.S.

    1985-06-11

    Disclosed is a thin film heterojunction solar cell, said heterojunction comprising a p-type I-III-IV[sub 2] chalcopyrite substrate and an overlying layer of an n-type ternary mixed metal compound wherein said ternary mixed metal compound is applied to said substrate by introducing the vapor of a first metal compound to a vessel containing said substrate from a first vapor source while simultaneously introducing a vapor of a second metal compound from a second vapor source of said vessel, said first and second metals comprising the metal components of said mixed metal compound; independently controlling the vaporization rate of said first and second vapor sources; reducing the mean free path between vapor particles in said vessel, said gas being present in an amount sufficient to induce homogeneity of said vapor mixture; and depositing said mixed metal compound on said substrate in the form of a uniform composition polycrystalline mixed metal compound. 5 figs.

  16. [A surgical case of mesial temporal lobe epilepsy associated with hippocampal sclerosis and traumatic neocortical lesion].

    PubMed

    Kitazawa, Yu; Jin, Kazutaka; Iwasaki, Masaki; Suzuki, Hiroyoshi; Tanaka, Fumiaki; Nakasato, Nobukazu

    2017-11-25

    A 26-year-old right-handed woman, with a history of left temporal lobe contusion caused by a fall at the age of 9 months, started to have complex partial seizures with oral automatism at the age of 7 years. The seizures occurred once or twice a month despite combination therapy with several antiepileptic agents. Her history and imaging studies suggested the diagnosis of epilepsy arising from traumatic neocortical temporal lesion. Comprehensive assessment including long-term video EEG monitoring, MRI, FDG-PET, MEG, and neuropsychological evaluation was performed at the age of 26 years. The diagnosis was left mesial temporal lobe epilepsy associated with hippocampal atrophy and traumatic temporal cortical lesion. The patient was readmitted for surgical treatment at the age of 27 years. Intracranial EEG monitoring showed that ictal discharges started in the left hippocampus and spread to the traumatic lesion in the left posterior superior temporal gyrus 10 seconds after the onset. This case could not be classified as dual pathology exactly, because the traumatic left temporal cortical lesion did not show independent epileptogenicity. However, the traumatic lesion was highly likely to be the source of the epileptogenicity, and she had right hemispheric dominance for language and functional deterioration in the whole temporal cortex. Therefore, left amygdalo-hippocampectomy and left temporal lobectomy including the traumatic lesion were performed according to the diagnosis of dual pathology. Subsequently, she remained seizure-free for 3 years. Comprehensive assessment of seizure semiology, neurophysiology, neuroradiology, and neuropsychology is important to determine the optimum therapeutic strategies for drug-resistant epilepsy.

  17. Modular radiochemistry synthesis system

    DOEpatents

    Satyamurthy, Nagichettiar; Barrio, Jorge R.; Amarasekera, Bernard; Van Dam, Michael R.; Olma, Sebastian; Williams, Dirk; Eddings, Mark; Shen, Clifton Kwang-Fu

    2016-11-01

    A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.

  18. Modular radiochemistry synthesis system

    DOEpatents

    Satyamurthy, Nagichettiar; Barrio, Jorge R.; Amarasekera, Bernard; Van Dam, R. Michael; Olma, Sebastian; Williams, Dirk; Eddings, Mark; Shen, Clifton Kwang-Fu

    2015-12-15

    A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.

  19. Modular radiochemistry synthesis system

    DOEpatents

    Satyamurthy, Nagichettiar; Barrio, Jorge R; Amarasekera, Bernard; Van Dam, R. Michael; Olma, Sebastian; Williams, Dirk; Eddings, Mark A; Shen, Clifton Kwang-Fu

    2015-02-10

    A modular chemical production system includes multiple modules for performing a chemical reaction, particularly of radiochemical compounds, from a remote location. One embodiment comprises a reaction vessel including a moveable heat source with the position thereof relative to the reaction vessel being controllable from a remote position. Alternatively the heat source may be fixed in location and the reaction vial is moveable into and out of the heat source. The reaction vessel has one or more sealing plugs, the positioning of which in relationship to the reaction vessel is controllable from a remote position. Also the one or more reaction vessel sealing plugs can include one or more conduits there through for delivery of reactants, gases at atmospheric or an elevated pressure, inert gases, drawing a vacuum and removal of reaction end products to and from the reaction vial, the reaction vial with sealing plug in position being operable at elevated pressures. The modular chemical production system is assembled from modules which can each include operating condition sensors and controllers configured for monitoring and controlling the individual modules and the assembled system from a remote position. Other modules include, but are not limited to a Reagent Storage and Delivery Module, a Cartridge Purification Module, a Microwave Reaction Module, an External QC/Analysis/Purification Interface Module, an Aliquotting Module, an F-18 Drying Module, a Concentration Module, a Radiation Counting Module, and a Capillary Reactor Module.

  20. [Vascularloops in reconstructive microsurgery: A review of the literature].

    PubMed

    Shipkov, H; Traikova, N; Voinov, P; Boucher, F; Braye, F; Mojallal, A

    2014-02-01

    The success of free tissue transfer depends on the quality of vascular micro-anastomosis and recipient vessels. Adequate recipient vessels are sometimes not available near the recipient site for they can be either destroyed or of poor quality (radiotherapy, traumatism). In such cases, good quality recipient vessels are at a distance from the reconstructed site. If this distance is important flap pedicle lengthening implies - for the artery, for the vein or for both flap artery and vein. This lengthening can be carried out in two manners - by interpositional vein grafts (VG) or by a vascular loop (VL) in one or two stages. The aim of this study was to review the utilisation of VL and their type since their introduction in the clinical practice of reconstructive microsurgery. Two main types of VL are used - BV by VG and VL "in situ". Both of them can be carried out in one or two stages. Each of these techniques has its advantages and disadvantages. The overall data from the literature shows that VL are indicated in cases where both artery and vein are damaged or destroyed. There is not enough evidence concerning the VL in one or two stages but there are some tendencies in favour of the VL in one stage. The technique of VL seems to be more avantageous over the interpositional VG but with a smaller success rate compared to free-flaps with direct anastomosis to recipient vessels. Further studies are necessary to investigate these controversial questions. Copyright © 2013. Published by Elsevier SAS.

  1. The role of blood vessels in high-resolution volume conductor head modeling of EEG.

    PubMed

    Fiederer, L D J; Vorwerk, J; Lucka, F; Dannhauer, M; Yang, S; Dümpelmann, M; Schulze-Bonhage, A; Aertsen, A; Speck, O; Wolters, C H; Ball, T

    2016-03-01

    Reconstruction of the electrical sources of human EEG activity at high spatio-temporal accuracy is an important aim in neuroscience and neurological diagnostics. Over the last decades, numerous studies have demonstrated that realistic modeling of head anatomy improves the accuracy of source reconstruction of EEG signals. For example, including a cerebro-spinal fluid compartment and the anisotropy of white matter electrical conductivity were both shown to significantly reduce modeling errors. Here, we for the first time quantify the role of detailed reconstructions of the cerebral blood vessels in volume conductor head modeling for EEG. To study the role of the highly arborized cerebral blood vessels, we created a submillimeter head model based on ultra-high-field-strength (7T) structural MRI datasets. Blood vessels (arteries and emissary/intraosseous veins) were segmented using Frangi multi-scale vesselness filtering. The final head model consisted of a geometry-adapted cubic mesh with over 17×10(6) nodes. We solved the forward model using a finite-element-method (FEM) transfer matrix approach, which allowed reducing computation times substantially and quantified the importance of the blood vessel compartment by computing forward and inverse errors resulting from ignoring the blood vessels. Our results show that ignoring emissary veins piercing the skull leads to focal localization errors of approx. 5 to 15mm. Large errors (>2cm) were observed due to the carotid arteries and the dense arterial vasculature in areas such as in the insula or in the medial temporal lobe. Thus, in such predisposed areas, errors caused by neglecting blood vessels can reach similar magnitudes as those previously reported for neglecting white matter anisotropy, the CSF or the dura - structures which are generally considered important components of realistic EEG head models. Our findings thus imply that including a realistic blood vessel compartment in EEG head models will be helpful to improve the accuracy of EEG source analyses particularly when high accuracies in brain areas with dense vasculature are required. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Induced natural convection thermal cycling device

    DOEpatents

    Heung, Leung Kit [Aiken, SC

    2002-08-13

    A device for separating gases, especially isotopes, by thermal cycling of a separation column using a pressure vessel mounted vertically and having baffled sources for cold and heat. Coils at the top are cooled with a fluid such as liquid nitrogen. Coils at the bottom are either electrical resistance coils or a tubular heat exchange. The sources are shrouded with an insulated "top hat" and simultaneously opened and closed at the outlets to cool or heat the separation column. Alternatively, the sources for cold and heat are mounted separately outside the vessel and an external loop is provided for each circuit.

  3. System for thermal energy storage, space heating and cooling and power conversion

    DOEpatents

    Gruen, Dieter M.; Fields, Paul R.

    1981-04-21

    An integrated system for storing thermal energy, for space heating and cong and for power conversion is described which utilizes the reversible thermal decomposition characteristics of two hydrides having different decomposition pressures at the same temperature for energy storage and space conditioning and the expansion of high-pressure hydrogen for power conversion. The system consists of a plurality of reaction vessels, at least one containing each of the different hydrides, three loops of circulating heat transfer fluid which can be selectively coupled to the vessels for supplying the heat of decomposition from any appropriate source of thermal energy from the outside ambient environment or from the spaces to be cooled and for removing the heat of reaction to the outside ambient environment or to the spaces to be heated, and a hydrogen loop for directing the flow of hydrogen gas between the vessels. When used for power conversion, at least two vessels contain the same hydride and the hydrogen loop contains an expansion engine. The system is particularly suitable for the utilization of thermal energy supplied by solar collectors and concentrators, but may be used with any source of heat, including a source of low-grade heat.

  4. Background gas density and beam losses in NIO1 beam source

    NASA Astrophysics Data System (ADS)

    Sartori, E.; Veltri, P.; Cavenago, M.; Serianni, G.

    2016-02-01

    NIO1 (Negative Ion Optimization 1) is a versatile ion source designed to study the physics of production and acceleration of H- beams up to 60 keV. In ion sources, the gas is steadily injected in the plasma source to sustain the discharge, while high vacuum is maintained by a dedicated pumping system located in the vessel. In this paper, the three dimensional gas flow in NIO1 is studied in the molecular flow regime by the Avocado code. The analysis of the gas density profile along the accelerator considers the influence of effective gas temperature in the source, of the gas temperature accommodation by collisions at walls, and of the gas particle mass. The calculated source and vessel pressures are compared with experimental measurements in NIO1 during steady gas injection.

  5. Influence and Modeling of Residual Stresses in Thick Walled Pressure Vessels with Through Holes

    DTIC Science & Technology

    2012-02-28

    9 FIGURE 4 ENVIRONMENTAL CRACKING OBSERVED IN EVACUATOR HOLE .......... 9 FIGURE 5 STRESSES PRESENT IN STRAIGHT EVACUATOR... ASSESMENT OF INITIAL DAMAGE Through investigation was undertaken on vessels similar in size and strength level to pressure vessels 85A and 85B...suggesting that the source of the residual stresses required to initiate and propagate these environmental cracks is not a resultant of the typical

  6. Tubular Tissues and Organs of Human Body--Challenges in Regenerative Medicine.

    PubMed

    Góra, Aleksander; Pliszka, Damian; Mukherjee, Shayanti; Ramakrishna, Seeram

    2016-01-01

    Tissue engineering of tubular organs such as the blood vessel, trachea gastrointestinal tract, urinary tract are of the great interest due to the high amount of surgeries performed annually on those organs. Development in tissue engineering in recent years and promising results, showed need to investigate more complex constructs that need to be designed in special manner. Stent technology remain the most widely used procedure to restore functions of tubular tissues after cancer treatment, or after organ removal due to traumatic accidents. Tubular structures like blood vessels, intestines, and trachea have to work in specific environment at the boundary of the liquids, solids or air and surrounding tissues and ensure suitable separation between them. This brings additional challenges in tissue engineering science in order to construct complete organs by using combinations of various cells along with the support material systems. Here we give a comprehensive review of the tubular structures of the human body, in perspective of the current methods of treatment and progress in regenerative medicine that aims to develop fully functioning organs of tubular shape. Extensive analysis of the available literature has been done focusing on materials and methods of creations of such organs. This work describes the attempts to incorporate growth factors and drugs within the scaffolds to ensure localized drug release and enhance vascularization of the organ by attracting blood vessels to the site of implantation.

  7. Staged curative treatment of a complex direct carotid-cavernous fistula with a large arterial defect and an 'oversized' internal carotid artery.

    PubMed

    Bender, Matthew T; Lin, Li-Mei; Coon, Alexander L; Colby, Geoffrey P

    2017-06-14

    This is a case of a high-flow, post-traumatic direct carotid-cavernous fistula with a widened arterial defect and a large-diameter internal carotid artery (ICA). The unique aspect of this case is the oversized ICA, >8mm in diameter, which is both a pathological and a therapeutic challenge, given the lack of available neuroendovascular devices for full vessel reconstruction. We present a planned two-stage embolisation paradigm for definitive treatment. Transarterial coil embolisation is performed as the first stage to disconnect the fistula and normalise flow in the ICA. A 3-month recovery period is then allowed for reduction in carotid diameter. Repair of the large vessel defect and pseudoaneurysm is performed as a second stage in a delayed fashion with a flow-diverting device. Follow-up angiography at 6 months demonstrates obliteration of the fistula and curative ICA reconstruction to a diameter <5mm. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Deep intracerebral (basal ganglia) haematomas in fatal non-missile head injury in man.

    PubMed Central

    Adams, J H; Doyle, D; Graham, D I; Lawrence, A E; McLellan, D R

    1986-01-01

    Deep intracerebral (basal ganglia) haematomas were found post mortem in 63 of 635 fatal non-missile head injuries. In patients with a basal ganglia haematoma, contusions were more severe, there was a reduced incidence of a lucid interval, and there was an increased incidence of road traffic accidents, gliding contusions and diffuse axonal injury than in patients without this type of haematoma. Intracranial haematoma is usually thought to be a secondary event, that is a complication of the original injury, but these results suggest that a deep intracerebral haematoma is a primary event. If a deep intracerebral haematoma is identified on an early CT scan it is likely that the patient has sustained severe diffuse brain damage at the time of injury. In the majority of head injuries damage to blood vessels or axons predominates. In patients with a traumatic deep intracerebral haematoma, it would appear that the deceleration/acceleration forces are such that both axons and blood vessels within the brain are damaged at the time of injury. Images PMID:3760892

  9. Nontraumatic Retroperitoneal Hematoma After Warfarin Administration: Fatal Case Report and Review of the Literature.

    PubMed

    Hosseini, Marzieh; Hosseinzadeh, Amin; Raufian, Kasra; Hedjazi, Arya

    2015-12-01

    Spontaneous retroperitoneal hematoma after warfarin therapy is an extremely rare event. Here, we report a 25-year-old man who was brought in to the emergency service with confusion. On arrival, the patient had hypotension, tachycardia, tachypnea, low-grade fever, and Glasgow Coma Scale score of 12. Abdominal examination revealed distention and mild tenderness in the right upper quadrant of the abdomen. The patient had a history of aortic valve replacement surgery and was on warfarin treatment at an international normalized ratio of 2.4. Our patient progressed to cardiorespiratory arrest. The resuscitation was initiated promptly. Despite all resuscitation measures, including transfusion and administration of high doses of catecholamine, the patient died of hypovolemic shock 3 hours after admission. At autopsy, the external surface of the abdominal great vessels (descending aorta and mesenteric vessels) showed scattered petechial hemorrhages without any visible site of perforation. After comprehensive exploration of the abdomen, no evidence of traumatic event was identified and the cause of internal blood loss was noted as warfarin adverse effect.

  10. Clinical trials in mild traumatic brain injury.

    PubMed

    Hoffer, Michael E; Szczupak, Mikhaylo; Balaban, Carey

    2016-10-15

    Traumatic brain injury is an increasingly prevalent injury seen in both civilian and military populations. Regardless of the mechanisms of injury, the most common sub-type of injury continues to be mild traumatic brain injury. Within the last decade, there has been tremendous growth in the literature regarding this disease entity. To describe the obstacles necessary to overcome in performing a rigorous and sound clinical research study investigating mild traumatic brain injury. This examination begins by a consideration of changing standards for good faith open and total reporting of any and all conflicts of interest or commitment. This issue is particularly critical in mTBI research. We next examine obstacles that include but are not limited to diagnostic criteria, inclusion/exclusion criteria, source of injury, previous history of injury, presence of comorbid conditions and proper informed consent of participants. Frequently, multi-center studies are necessary for adequate subject accrual with the added challenges of site coordination, data core management and site specific study conduct. We propose a total reversal to the traditional translational research approach where clinical studies drive new concepts for future basic science studies. There have been few mild traumatic brain injury clinical trials in the literature with treatments/interventions that have been able to overcome many of these described obstacles. We look forward to the results of current and ongoing clinical mild traumatic brain injury studies providing the tools necessary for the next generation of basic science projects. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Exploiting Electric and Magnetic Fields for Underwater Characterization

    DTIC Science & Technology

    2011-03-01

    geophysical surveys are primarily limited to passive magnetic systems towed from a surface vessel. These systems utilize fluxgate , Overhauser, or atomic... magnetometer sensors, often deployed in arrays towed from the stern of small to moderate-size vessels. Active source electromagnetic methods have been

  12. 46 CFR 129.370 - Equipment grounding.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Equipment grounding. 129.370 Section 129.370 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.370 Equipment grounding. (a) On a metallic vessel...

  13. 46 CFR 129.370 - Equipment grounding.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Equipment grounding. 129.370 Section 129.370 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.370 Equipment grounding. (a) On a metallic vessel...

  14. 46 CFR 129.370 - Equipment grounding.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Equipment grounding. 129.370 Section 129.370 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.370 Equipment grounding. (a) On a metallic vessel...

  15. Youth Responses to School Shootings: a Review.

    PubMed

    Travers, Áine; McDonagh, Tracey; Elklit, Ask

    2018-05-19

    This paper aims to synthesize research relating to youth responses to school shootings between 2014 and 2017. The main questions it addresses are how such events impact young people psychologically, and what risk or protective factors may contribute to different trajectories of recovery? Recent research suggests that most young people exposed to school shootings demonstrate resilience, exhibiting no long-term dysfunction. However, a minority will experience severe and chronic symptoms. The likelihood of experiencing clinically significant reactions is influenced by pre-trauma functioning as well as peri-traumatic and post-traumatic factors. These include proximity to the trauma, peri-traumatic dissociation, post-traumatic emotional regulation difficulties, social support, and flexibility of coping styles. Research that separates the distinguishing features of young people with differing recovery styles is vital to tailor intervention. But methodological and design issues associated with such research necessitates caution in drawing conclusions. Variation in definitions and measures and the self-report nature of many of the studies are potential sources of bias. Greater uniformity across designs would enhance confidence and allow for improved evidence-based intervention.

  16. Is phosphorylated tau unique to chronic traumatic encephalopathy? Phosphorylated tau in epileptic brain and chronic traumatic encephalopathy.

    PubMed

    Puvenna, Vikram; Engeler, Madeline; Banjara, Manoj; Brennan, Chanda; Schreiber, Peter; Dadas, Aaron; Bahrami, Ashkon; Solanki, Jesal; Bandyopadhyay, Anasua; Morris, Jacqueline K; Bernick, Charles; Ghosh, Chaitali; Rapp, Edward; Bazarian, Jeffrey J; Janigro, Damir

    2016-01-01

    Repetitive traumatic brain injury (rTBI) is one of the major risk factors for the abnormal deposition of phosphorylated tau (PT) in the brain and chronic traumatic encephalopathy (CTE). CTE and temporal lobe epilepsy (TLE) affect the limbic system, but no comparative studies on PT distribution in TLE and CTE are available. It is also unclear whether PT pathology results from repeated head hits (rTBI). These gaps prevent a thorough understanding of the pathogenesis and clinical significance of PT, limiting our ability to develop preventative and therapeutic interventions. We quantified PT in TLE and CTE to unveil whether a history of rTBI is a prerequisite for PT accumulation in the brain. Six postmortem CTE (mean 73.3 years) and age matched control samples were compared to 19 surgically resected TLE brain specimens (4 months-58 years; mean 27.6 years). No history of TBI was present in TLE or control; all CTE patients had a history of rTBI. TLE and CTE brain displayed increased levels of PT as revealed by immunohistochemistry. No age-dependent changes were noted, as PT was present as early as 4 months after birth. In TLE and CTE, cortical neurons, perivascular regions around penetrating pial vessels and meninges were immunopositive for PT; white matter tracts also displayed robust expression of extracellular PT organized in bundles parallel to venules. Microscopically, there were extensive tau-immunoreactive neuronal, astrocytic and degenerating neurites throughout the brain. In CTE perivascular tangles were most prominent. Overall, significant differences in staining intensities were found between CTE and control (P<0.01) but not between CTE and TLE (P=0.08). pS199 tau analysis showed that CTE had the most high molecular weight tangle-associated tau, whereas epileptic brain contained low molecular weight tau. Tau deposition may not be specific to rTBI since TLE recapitulated most of the pathological features of CTE. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Is phosphorylated tau unique to chronic traumatic encephalopathy? Phosphorylated tau in epileptic brain and chronic traumatic encephalopathy

    PubMed Central

    Puvenna, Vikram; Engeler, Madeline; Banjara, Manoj; Brennan, Chanda; Schreiber, Peter; Dadas, Aaron; Bahrami, Ashkon; Solanki, Jesal; Bandyopadhyay, Anasua; Morris, Jacqueline K.; Bernick, Charles; Ghosh, Chaitali; Bazarian, Jeffrey J.; Janigro, Damir

    2016-01-01

    Repetitive traumatic brain injury (rTBI) is one of the major risk factors for the abnormal deposition of phosphorylated tau (PT) in the brain and chronic traumatic encephalopathy (CTE). CTE and temporal lobe epilepsy (TLE) affect the limbic system, but no comparative studies on PT distribution in TLE and CTE are available. It is also unclear whether PT pathology results from repeated head hits (rTBI). These gaps prevent a thorough understanding of the pathogenesis and clinical significance of PT, limiting our ability to develop preventative and therapeutic interventions. We quantified PT in TLE and CTE to unveil whether a history of rTBI is a prerequisite for PT accumulation in the brain. Six post mortem CTE (mean 73.3 years) and age matched control samples were compared to 19 surgically resected TLE brain specimens (4 months-58 years; mean 27.6 years). No history of TBI was present in TLE or control; all CTE patients had a history of rTBI. TLE and CTE brain displayed increased levels of PT as revealed by immunohistochemistry. No age-dependent changes were noted, as PT was present as early as 4 months after birth. In TLE and CTE, cortical neurons, perivascular regions around penetrating pial vessels and meninges were immunopositive for PT; white matter tracts also displayed robust expression of extracellular PT organized in bundles parallel to venules. Microscopically, there were extensive tau-immunoreactive neuronal, astrocytic and degenerating neurites throughout the brain. In CTE perivascular tangles were most prominent. Overall, significant differences in staining intensities were found between CTE and control (P<0.01) but not between CTE and TLE (P=0.08). pS199 tau analysis showed that CTE had the most high molecular weight tangle-associated tau, whereas epileptic brain contained low molecular weight tau. Tau deposition may not be specific to rTBI since TLE recapitulated most of the pathological features of CTE. PMID:26556772

  18. Pediatric thoracic SCIWORA after back bend during dance practice: a retrospective case series and analysis of trauma mechanisms.

    PubMed

    Ren, Jian; Zeng, Gao; Ma, Yong-Jie; Chen, Nan; Chen, Zan; Ling, Feng; Zhang, Hong-Qi

    2017-07-01

    The purpose of the study was to describe a unique type of low-energy traumatic pediatric thoracic spinal cord injury without radiographic abnormality (SCIWORA) after a back bend during dance practice and analyze the trauma mechanisms and treatment protocols. This was a retrospective case series from September 2007 to August 2016. The study was conducted at a tertiary medical center in Beijing, China (Xuanwu Hospital, China International Neuroscience Institute [China-INI], Capital Medical University). A total of 12 pediatric patients who had a clear traumatic history after back bend movements and had been diagnosed with thoracic SCIWORA were included. Clinical and imaging data were obtained for each patient. The follow-up data was analyzed. The traumatic mechanisms were investigated by analyzing the patients' medical history, spinal diffusion tensor imaging (DTI) and fiber tractography data. Of the 12 patients, 11 (91.7%) were younger than 8 years old. The mean age of the patients was 6.6 years. All patients had a clear traumatic history of severe thoracic spinal cord injury after performing back bend movements. The mean follow-up time was 36.5 months. During the follow-up period, 1 patient (8.3%) recovered completely, and 11 patients (91.7%) had unfavorable prognoses, including 4 (33.3%) with incomplete recovery and 7 (58.3%) with no change. Two patients underwent spinal DTI, which showed rupture of the nerve fiber bundle in the section of the injury. Back bend movements performed during dance practice may cause pediatric thoracic SCIWORA, particularly in children younger than 8 years old. We suggest that the mechanism of primary injury is the longitudinal distraction of the thoracic spine during back bend movements, which leads to violent distraction of the spinal cord and blunt injury of nerve axons, nerve cells, and small vessels. Spinal DTI may facilitate the diagnosis and prognostic evaluation of SCIWORA.

  19. Modeling the fate of p,p'-DDT in water and sediment of two typical estuarine bays in South China: Importance of fishing vessels' inputs.

    PubMed

    Fang, Shu-Ming; Zhang, Xianming; Bao, Lian-Jun; Zeng, Eddy Y

    2016-05-01

    Antifouling paint applied to fishing vessels is the primary source of dichloro-diphenyl-trichloroethane (DDT) to the coastal marine environments of China. With the aim to provide science-based support of potential regulations on DDT use in antifouling paint, we utilized a fugacity-based model to evaluate the fate and impact of p,p'-DDT, the dominant component of DDT mixture, in Daya Bay and Hailing Bay, two typical estuarine bays in South China. The emissions of p,p'-DDT from fishing vessels to the aquatic environments of Hailing Bay and Daya Bay were estimated as 9.3 and 7.7 kg yr(-1), respectively. Uncertainty analysis indicated that the temporal variability of p,p'-DDT was well described by the model if fishing vessels were considered as the only direct source, i.e., fishing vessels should be the dominant source of p,p'-DDT in coastal bay areas of China. Estimated hazard quotients indicated that sediment in Hailing Bay posed high risk to the aquatic system, and it would take at least 21 years to reduce the hazards to a safe level. Moreover, p,p'-DDT tends to migrate from water to sediment in the entire Hailing Bay and Daya Bay. On the other hand, our previous research indicated that p,p'-DDT was more likely to migrate from sediment to water in the maricultured zones located in shallow waters of these two bays, where fishing vessels frequently remain. These findings suggest that relocating mariculture zones to deeper waters would reduce the likelihood of farmed fish contamination by p,p'-DDT. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Electricity generation using electromagnetic radiation

    DOEpatents

    Halas, Nancy J.; Nordlander, Peter; Neumann, Oara

    2017-08-22

    In general, in one aspect, the invention relates to a system to create vapor for generating electric power. The system includes a vessel comprising a fluid and a complex and a turbine. The vessel of the system is configured to concentrate EM radiation received from an EM radiation source. The vessel of the system is further configured to apply the EM radiation to the complex, where the complex absorbs the EM radiation to generate heat. The vessel of the system is also configured to transform, using the heat generated by the complex, the fluid to vapor. The vessel of the system is further configured to sending the vapor to a turbine. The turbine of the system is configured to receive, from the vessel, the vapor used to generate the electric power.

  1. A new fundamental bioheat equation for muscle tissue--part II: Temperature of SAV vessels.

    PubMed

    Zhu, Liang; Xu, Lisa X; He, Qinghong; Weinbaum, Sheldon

    2002-02-01

    In this study, a new theoretical framework was developed to investigate temperature variations along countercurrent SAV blood vessels from 300 to 1000 microm diameter in skeletal muscle. Vessels of this size lie outside the range of validity of the Weinbaum-Jiji bioheat equation and, heretofore, have been treated using discrete numerical methods. A new tissue cylinder surrounding these vessel pairs is defined based on vascular anatomy, Murray's law, and the assumption of uniform perfusion. The thermal interaction between the blood vessel pair and surrounding tissue is investigated for two vascular branching patterns, pure branching and pure perfusion. It is shown that temperature variations along these large vessel pairs strongly depend on the branching pattern and the local blood perfusion rate. The arterial supply temperature in different vessel generations was evaluated to estimate the arterial inlet temperature in the modified perfusion source term for the s vessels in Part I of this study. In addition, results from the current research enable one to explore the relative contribution of the SAV vessels and the s vessels to the overall thermal equilibration between blood and tissue.

  2. The neuropathology of chronic traumatic encephalopathy.

    PubMed

    McKee, Ann C; Stein, Thor D; Kiernan, Patrick T; Alvarez, Victor E

    2015-05-01

    Repetitive brain trauma is associated with a progressive neurological deterioration, now termed as chronic traumatic encephalopathy (CTE). Most instances of CTE occur in association with the play of sports, but CTE has also been reported in association with blast injuries and other neurotrauma. Symptoms of CTE include behavioral and mood changes, memory loss, cognitive impairment and dementia. Like many other neurodegenerative diseases, CTE is diagnosed with certainty only by neuropathological examination of brain tissue. CTE is a tauopathy characterized by the deposition of hyperphosphorylated tau (p-tau) protein as neurofibrillary tangles, astrocytic tangles and neurites in striking clusters around small blood vessels of the cortex, typically at the sulcal depths. Severely affected cases show p-tau pathology throughout the brain. Abnormalities in phosphorylated 43 kDa TAR DNA-binding protein are found in most cases of CTE; beta-amyloid is identified in 43%, associated with age. Given the importance of sports participation and physical exercise to physical and psychological health as well as disease resilience, it is critical to identify the genetic risk factors for CTE as well as to understand how other variables, such as stress, age at exposure, gender, substance abuse and other exposures, contribute to the development of CTE. © 2015 International Society of Neuropathology.

  3. Acute severe neck pain and dysphagia following cervical maneuver: diagnostic approach.

    PubMed

    Trendel, D; Bonfort, G; Lapierre-Combes, M; Salf, E; Barberot, J-P

    2014-04-01

    Overlooking an etiologic hypothesis in acute neck pain with dysphagia may lead to misdiagnosis. A 51-year-old man who had received cervical manipulation came to the emergency unit with evolutive acute neck pain, cervical spine stiffness and odynophagia, without fever or other signs of identified pathology. Cervical X-ray and CT angiography of the supra-aortic vessels ruled out traumatic etiology (fracture or arterial dissection) and revealed an accessory bone, orienting diagnosis toward retropharyngeal abscess, which was, however, belied by endoscopy performed under general anesthesia. A second CT scan with contrast injection and tissue phase ruled out infection, revealing a retropharyngeal calcification inducing retropharyngeal edema. Evolution under analgesics was favorable within 13 days. Given a clinical triad associating acute neck pain, cervical spine stiffness and odynophagia, traumatic or infectious etiology was initially suspected. Cervical CT diagnosed calcific tendinitis of the longus colli, revealing a pathognomic retropharyngeal calcification. Secondary to hydroxyapatite deposits anterior to the odontoid process of the axis, this is a rare form of tendinopathy, usually showing favorable evolution in 10-15 days under analgesic and anti-inflammatory treatment. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  4. The Neuropathology of Chronic Traumatic Encephalopathy

    PubMed Central

    McKee, Ann C.; Stein, Thor D.; Kiernan, Patrick T.; Alvarez, Victor E.

    2015-01-01

    Repetitive brain trauma is associated with a progressive neurological deterioration, now termed as chronic traumatic encephalopathy (CTE). Most instances of CTE occur in association with the play of sports, but CTE has also been reported in association with blast injuries and other neurotrauma. Symptoms of CTE include behavioral and mood changes, memory loss, cognitive impairment and dementia. Like many other neurodegenerative diseases, CTE is diagnosed with certainty only by neuropathological examination of brain tissue. CTE is a tauopathy characterized by the deposition of hyperphosphorylated tau (p-tau) protein as neurofibrillary tangles, astrocytic tangles and neurites in striking clusters around small blood vessels of the cortex, typically at the sulcal depths. Severely affected cases show p-tau pathology throughout the brain. Abnormalities in phosphorylated 43 kDa TAR DNA-binding protein are found in most cases of CTE; beta-amyloid is identified in 43%, associated with age. Given the importance of sports participation and physical exercise to physical and psychological health as well as disease resilience, it is critical to identify the genetic risk factors for CTE as well as to understand how other variables, such as stress, age at exposure, gender, substance abuse and other exposures, contribute to the development of CTE. PMID:25904048

  5. Imaging pulse wave velocity in mouse retina using swept-source OCT (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Song, Shaozhen; Wei, Wei; Wang, Ruikang K.

    2016-03-01

    Blood vessel dynamics has been a significant subject in cardiology and internal medicine, and pulse wave velocity (PWV) on artery vessels is a classic evaluation of arterial distensibility, and has never been ascertained as a cardiovascular risk marker. The aim of this study is to develop a high speed imaging technique to capture the pulsatile motion on mouse retina arteries with the ability to quantify PWV on any arterial vessels. We demonstrate a new non-invasive method to assess the vessel dynamics on mouse retina. A Swept-source optical coherence tomography (SS-OCT) system is used for imaging micro-scale blood vessel motion. The phase-stabilized SS-OCT provides a typical displacement sensitivity of 20 nm. The frame rate of imaging is ~16 kHz, at A-line rate of ~1.62 MHz, which allows the detection of transient pulse waves with adequate temporal resolution. Imaging volumes with repeated B-scans are obtained on mouse retina capillary bed, and the mouse oxymeter signal is recorded simultaneously. The pulse wave on artery and vein are resolved, and with the synchronized heart beat signal, the temporal delay on different vessel locations is determined. The vessel specific measurement of PWV is achieved for the first time with SS-OCT, for pulse waves propagating more than 100 cm/s. Using the novel methodology of retinal PWV assessment, it is hoped that the clinical OCT scans can provide extended diagnostic information of cardiology functionalities.

  6. Advanced Demonstration of Motion Correction for Ship-to-Ship Passive Inspections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziock, Klaus-Peter; Boehnen, Chris Bensing; Ernst, Joseph

    2013-09-30

    Passive radiation detection is a key tool for detecting illicit nuclear materials. In maritime applications it is most effective against small vessels where attenuation is of less concern. Passive imaging provides: discrimination between localized (threat) and distributed (non-threat) sources, removal of background fluctuations due to nearby shorelines and structures, source localization to an individual craft in crowded waters, and background subtracted spectra. Unfortunately, imaging methods cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing sensitivity. This is particularly true for the smaller water craft where passive inspections aremore » most valuable. In this project we performed tests and improved the performance of an instrument (developed earlier under, “Motion Correction for Ship-to-Ship Passive Inspections”) that uses automated tracking of a target vessel in visible-light images to generate a 3D radiation map of the target vessel from data obtained using a gamma-ray imager.« less

  7. Initial observations of cavitation-induced erosion of liquid metal spallation target vessels at the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClintock, David A; Riemer, Bernie; Ferguson, Phillip D

    2012-01-01

    During operation of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory the mechanical properties of the AISI 316L target module are altered by high-energy neutron and proton radiation. The interior surfaces of the target vessel are also damaged by cavitation-induced erosion, which results from repetitive rapid heating of the liquid mercury by high-energy proton beam pulses. Until recently no observations of cavitation-induced erosion were possible for conditions prototypical to the SNS. Post irradiation examination (PIE) of the first and second operational SNS targets was performed to gain insight into the radiation-induced changes in mechanical properties of the 316Lmore » target material and the extent of cavitation-induced erosion to the target vessel inner surfaces. Observations of cavitation-induced erosion of the first and second operational SNS target modules are presented here, including images of the target vessel interiors and specimens removed from the target beam-entrance regions.« less

  8. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    NASA Astrophysics Data System (ADS)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  9. Vessel V-7 and V-8 repair and characterization of insert material. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Domian, H.A.

    1984-05-01

    Pieces of Type SA508-2 steel, specially tempered to produce a high-impact-transition temperature, were welded in the side walls of Intermediate Test Vessels V-7 and V-8. These vessels are to be tested by the Oak Ridge National Laboratory (ORNL) in the Pressurized-Thermal-Shock (PTS) Project of the Heavy-Section Steel Technology (HSST) Program. A comparable piece of forging taken from the same source and heat treated with the vessels was characterized for its mechanical properties to provide data for use in the PTS tests.

  10. [Macro- and microscopic systematization of cerebral cortex malformations in children].

    PubMed

    Milovanov, A P; Milovanova, O A

    2011-01-01

    For the first time in pediatric pathologicoanatomic practice the complete systematization of cerebral cortex malformations is represented. Organ, macroscopic forms: microencephaly, macroencephaly, micropolygyria, pachygyria, schizencephaly, porencephaly, lissencephaly. Histic microdysgenesis of cortex: type I includes isolated abnormalities such as radial (IA) and tangential (I B) subtypes of cortical dislamination; type II includes sublocal cortical dislamination with immature dysmorphic neurons (II A) and balloon cells (II B); type III are the combination focal cortical dysplasia with tuberous sclerosis of the hippocampus (III A), tumors (III B) and malformations of vessels, traumatic and hypoxic disorders (III C). Band heterotopias. Subependimal nodular heterotopias. Tuberous sclerosis. Cellular typification of cortical dysplasia: immature neurons and balloon cells.

  11. Utility of a Work Process Classification System for characterizing non-fatal injuries in the Alaskan commercial fishing industry

    PubMed Central

    Syron, Laura N.; Lucas, Devin L.; Bovbjerg, Viktor E.; Bethel, Jeffrey W.; Kincl, Laurel D.

    2016-01-01

    Background The US commercial fishing industry is hazardous, as measured by mortality data. However, research on non-fatal injuries is limited. Non-fatal injuries constitute the majority of occupational injuries and can result in workers’ lowered productivity and wages, lost quality of life, and disability. In the United States, a Work Process Classification System (WPCS) has previously been applied in Alaskan freezer-trawl and freezer-longline fleets to identify causes of injuries and specific hazards, but not to other fishing fleets. Objectives This descriptive epidemiologic study aimed to explore the application and modification of the WPCS in multiple Alaskan fleets, characterize non-fatal occupational injuries in these fleets, and identify work processes that could be targeted for further investigation and future injury prevention efforts. Design Traumatic, non-fatal injuries on-board Alaskan commercial fishing vessels were identified through United States Coast Guard investigative reports. Characteristics of injuries, as well as worker characteristics, were analysed. Injuries were coded using the WPCS. Results We successfully utilized the WPCS to code non-fatal injury cases (n = 136). The most frequent main work processes associated with non-fatal injuries included: on-board trawlers, handling frozen fish and processing the catch; on-board vessels using pot/trap gear, handling the gear and shooting/setting the gear; on-board longliners, traffic on board and hauling the gear; and on-board processor vessels, processing the catch, other work with the catch, and handling frozen fish. Conclusions The study confirmed that a WPCS can be applied to multiple Alaskan fleets to identify hazardous tasks. Hazards were unique for each vessel gear type. Future injury prevention efforts should target work processes associated with the most frequent and most severe injuries. Future studies should establish time estimates for work processes in order to determine risk estimates. Efforts to improve non-fatal injury reporting, especially on smaller commercial fishing vessels, should be undertaken. PMID:26782030

  12. Utility of a Work Process Classification System for characterizing non-fatal injuries in the Alaskan commercial fishing industry.

    PubMed

    Syron, Laura N; Lucas, Devin L; Bovbjerg, Viktor E; Bethel, Jeffrey W; Kincl, Laurel D

    2016-01-01

    Background The US commercial fishing industry is hazardous, as measured by mortality data. However, research on non-fatal injuries is limited. Non-fatal injuries constitute the majority of occupational injuries and can result in workers' lowered productivity and wages, lost quality of life, and disability. In the United States, a Work Process Classification System (WPCS) has previously been applied in Alaskan freezer-trawl and freezer-longline fleets to identify causes of injuries and specific hazards, but not to other fishing fleets. Objectives This descriptive epidemiologic study aimed to explore the application and modification of the WPCS in multiple Alaskan fleets, characterize non-fatal occupational injuries in these fleets, and identify work processes that could be targeted for further investigation and future injury prevention efforts. Design Traumatic, non-fatal injuries on-board Alaskan commercial fishing vessels were identified through United States Coast Guard investigative reports. Characteristics of injuries, as well as worker characteristics, were analysed. Injuries were coded using the WPCS. Results We successfully utilized the WPCS to code non-fatal injury cases (n = 136). The most frequent main work processes associated with non-fatal injuries included: on-board trawlers, handling frozen fish and processing the catch; on-board vessels using pot/trap gear, handling the gear and shooting/setting the gear; on-board longliners, traffic on board and hauling the gear; and on-board processor vessels, processing the catch, other work with the catch, and handling frozen fish. Conclusions The study confirmed that a WPCS can be applied to multiple Alaskan fleets to identify hazardous tasks. Hazards were unique for each vessel gear type. Future injury prevention efforts should target work processes associated with the most frequent and most severe injuries. Future studies should establish time estimates for work processes in order to determine risk estimates. Efforts to improve non-fatal injury reporting, especially on smaller commercial fishing vessels, should be undertaken.

  13. Utility of a Work Process Classification System for characterizing non-fatal injuries in the Alaskan commercial fishing industry.

    PubMed

    Syron, Laura N; Lucas, Devin L; Bovbjerg, Viktor E; Bethel, Jeffrey W; Kincl, Laurel D

    2016-01-01

    The US commercial fishing industry is hazardous, as measured by mortality data. However, research on non-fatal injuries is limited. Non-fatal injuries constitute the majority of occupational injuries and can result in workers' lowered productivity and wages, lost quality of life, and disability. In the United States, a Work Process Classification System (WPCS) has previously been applied in Alaskan freezer-trawl and freezer-longline fleets to identify causes of injuries and specific hazards, but not to other fishing fleets. This descriptive epidemiologic study aimed to explore the application and modification of the WPCS in multiple Alaskan fleets, characterize non-fatal occupational injuries in these fleets, and identify work processes that could be targeted for further investigation and future injury prevention efforts. Traumatic, non-fatal injuries on-board Alaskan commercial fishing vessels were identified through United States Coast Guard investigative reports. Characteristics of injuries, as well as worker characteristics, were analysed. Injuries were coded using the WPCS. We successfully utilized the WPCS to code non-fatal injury cases (n = 136). The most frequent main work processes associated with non-fatal injuries included: on-board trawlers, handling frozen fish and processing the catch; on-board vessels using pot/trap gear, handling the gear and shooting/setting the gear; on-board longliners, traffic on board and hauling the gear; and on-board processor vessels, processing the catch, other work with the catch, and handling frozen fish. The study confirmed that a WPCS can be applied to multiple Alaskan fleets to identify hazardous tasks. Hazards were unique for each vessel gear type. Future injury prevention efforts should target work processes associated with the most frequent and most severe injuries. Future studies should establish time estimates for work processes in order to determine risk estimates. Efforts to improve non-fatal injury reporting, especially on smaller commercial fishing vessels, should be undertaken.

  14. Development of Clostridium septicum gas gangrene as an adverse effect of clindamycin-induced Clostridium difficile infection in a pediatric patient.

    PubMed

    Kiser, Casey J; Urish, Kenneth L; Boateng, Henry A

    2014-09-01

    Clostridium myonecrosis or gas gangrene is a life-threatening infection characterized by either traumatic or atraumatic etiology. It has been widely described in patients with traumatic open wounds and in immunocompromised patients, including malignancy. A third source can result from natural flora in the gastrointestinal tract after bowel ischemia. This is a rare occurrence and is even less commonly described in the pediatric population. We present a pediatric patient who developed Clostridium septicum myonecrosis as an iatrogenic complication from clindamycin-induced Clostridium difficile ischemic colitis.

  15. NIR light propagation in a digital head model for traumatic brain injury (TBI)

    PubMed Central

    Francis, Robert; Khan, Bilal; Alexandrakis, George; Florence, James; MacFarlane, Duncan

    2015-01-01

    Near infrared spectroscopy (NIRS) is capable of detecting and monitoring acute changes in cerebral blood volume and oxygenation associated with traumatic brain injury (TBI). Wavelength selection, source-detector separation, optode density, and detector sensitivity are key design parameters that determine the imaging depth, chromophore separability, and, ultimately, clinical usefulness of a NIRS instrument. We present simulation results of NIR light propagation in a digital head model as it relates to the ability to detect intracranial hematomas and monitor the peri-hematomal tissue viability. These results inform NIRS instrument design specific to TBI diagnosis and monitoring. PMID:26417498

  16. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  17. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  18. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  19. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  20. 40 CFR 60.111 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... petroleum liquid being contained, and is equipped with a closure seal or seals to close the space between... PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Storage Vessels for Petroleum Liquids for... container used for the storage of petroleum liquids, but does not include: (1) Pressure vessels which are...

  1. 46 CFR 163.002-13 - Construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... sharp edges and projections of excessive length. A pilot hoist must not have nonfunctional sharp edges... vessel's side rails for support; and (3) Unobstructed passage between the ladder or lift platform of the... between the vessel's compressed air source and the pneumatic motor. (l) Hoist control lever. Each pilot...

  2. 46 CFR 163.002-13 - Construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... sharp edges and projections of excessive length. A pilot hoist must not have nonfunctional sharp edges... vessel's side rails for support; and (3) Unobstructed passage between the ladder or lift platform of the... between the vessel's compressed air source and the pneumatic motor. (l) Hoist control lever. Each pilot...

  3. 46 CFR 163.002-13 - Construction.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... sharp edges and projections of excessive length. A pilot hoist must not have nonfunctional sharp edges... vessel's side rails for support; and (3) Unobstructed passage between the ladder or lift platform of the... between the vessel's compressed air source and the pneumatic motor. (l) Hoist control lever. Each pilot...

  4. EN FACE IMAGING OF PACHYCHOROID SPECTRUM DISORDERS WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY.

    PubMed

    Dansingani, Kunal K; Balaratnasingam, Chandrakumar; Naysan, Jonathan; Freund, K Bailey

    2016-03-01

    To correlate clinical manifestations with choroidal morphology in pachychoroid disorders, including central serous chorioretinopathy, pachychoroid pigment epitheliopathy, pachychoroid neovasculopathy, and polypoidal choroidal vasculopathy, using en face swept-source optical coherence tomography (OCT). Patients with pachychoroid spectrum diagnoses were identified nonconsecutively through a review of charts and multimodal imaging. Each eye was categorized as uncomplicated pachychoroid, pachychoroid pigment epitheliopathy, central serous chorioretinopathy, pachychoroid neovasculopathy, or polypoidal choroidal vasculopathy. All patients included in this series then underwent bilateral swept-source OCT. Sixty-six eyes of 33 patients were included. Numbers assigned to diagnostic categories were 8 uncomplicated pachychoroid, 13 pachychoroid pigment epitheliopathy, 27 central serous chorioretinopathy, 15 pachychoroid neovasculopathy, and 3 polypoidal choroidal vasculopathy. One eye was classified as normal. Swept-source OCT choroidal thickness maps confirmed increased thickness under the areas of pachychoroid pigment epitheliopathy, central serous chorioretinopathy, type 1 NV (pachychoroid neovasculopathy), or polyps (polypoidal choroidal vasculopathy). En face swept-source OCT showed dilated outer choroidal vessels in all eyes. In several eyes with a chronic disease, focal choriocapillaris atrophy with inward displacement of deep choroidal vessels was noted. Although clinical manifestations of pachychoroid spectrum disorders vary considerably, these entities share morphologic findings in the choroid, including increased thickness and dilated outer choroidal vessels. En face swept-source OCT localizes these changes to disease foci and shows additional findings that may unify our understanding of disease pathogenesis.

  5. Heat-driven acoustic cooling engine having no moving parts

    DOEpatents

    Wheatley, John C.; Swift, Gregory W.; Migliori, Albert; Hofler, Thomas J.

    1989-01-01

    A heat-driven acoustic cooling engine having no moving parts receives heat from a heat source. The acoustic cooling engine comprises an elongated resonant pressure vessel having first and second ends. A compressible fluid having a substantial thermal expansion coefficient and capable of supporting an acoustic standing wave is contained in the resonant pressure vessel. The heat source supplies heat to the first end of the vessel. A first heat exchanger in the vessel is spaced-apart from the first end and receives heat from the first end. A first thermodynamic element is adjacent to the first heat exchanger and converts some of the heat transmitted by the first heat exchanger into acoustic power. A second thermodynamic element has a first end located spaced-apart from the first thermodynamic element and a second end farther away from the first thermodynamic element than is its first end. The first end of the second thermodynamic element heats while its second end cools as a consequence of the acoustic power. A second heat exchanger is adjacent to and between the first and second thermodynamic elements. A heat sink outside of the vessel is thermally coupled to and receives heat from the second heat exchanger. The resonant pressure vessel can include a housing less than one-fourth wavelength in length coupled to a reservoir. The housing can include a reduced diameter portion communicating with the reservoir.

  6. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pollution sources? (1) Particulate matter emissions from a combustion source stack (except for wood-fired..., British thermal unit (Btu), coal, combustion source, distillate fuel oil, emission, fuel, fuel oil, gaseous fuel, heat input, incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine...

  7. 78 FR 58415 - Oil and Natural Gas Sector: Reconsideration of Certain Provisions of New Source Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-23

    ...). C. Group 1 Storage Vessel Affected Facility Control Requirements The final amendments retain the... Control Requirements and Applicability We received comments requesting clarification regarding Group 1... there was confusion regarding the applicability of Group 1 storage vessel affected facility control...

  8. 46 CFR 199.110 - Survival craft muster and embarkation arrangements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power. (d) Each alleyway, stairway, and exit giving access to a muster and embarkation station must be adequately illuminated by lighting that is capable of having its power supplied by the vessel's...

  9. 46 CFR 199.110 - Survival craft muster and embarkation arrangements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power. (d) Each alleyway, stairway, and exit giving access to a muster and embarkation station must be adequately illuminated by lighting that is capable of having its power supplied by the vessel's...

  10. Neutron source

    DOEpatents

    Cason, J.L. Jr.; Shaw, C.B.

    1975-10-21

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap.

  11. 46 CFR 183.310 - Power sources.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Power sources. 183.310 Section 183.310 Shipping COAST...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be...

  12. 46 CFR 120.310 - Power sources.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power sources. 120.310 Section 120.310 Shipping COAST... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.310 Power sources. (a)(1) Each vessel that relies on electricity to...

  13. 46 CFR 183.310 - Power sources.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be... 46 Shipping 7 2013-10-01 2013-10-01 false Power sources. 183.310 Section 183.310 Shipping COAST...

  14. 46 CFR 183.310 - Power sources.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be... 46 Shipping 7 2012-10-01 2012-10-01 false Power sources. 183.310 Section 183.310 Shipping COAST...

  15. 46 CFR 183.310 - Power sources.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be... 46 Shipping 7 2014-10-01 2014-10-01 false Power sources. 183.310 Section 183.310 Shipping COAST...

  16. 46 CFR 183.310 - Power sources.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be... 46 Shipping 7 2011-10-01 2011-10-01 false Power sources. 183.310 Section 183.310 Shipping COAST...

  17. 46 CFR 120.310 - Power sources.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Power sources. 120.310 Section 120.310 Shipping COAST... PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.310 Power sources. (a)(1) Each vessel that relies on electricity to...

  18. 40 CFR 49.129 - Rule for limiting emissions of sulfur dioxide.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions from a combustion source stack must not exceed an average of 500 parts per million by volume, on a..., air pollution source, ambient air, British thermal unit (Btu), coal, combustion source, continuous..., incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, open burning...

  19. 40 CFR 49.129 - Rule for limiting emissions of sulfur dioxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... emissions from a combustion source stack must not exceed an average of 500 parts per million by volume, on a..., air pollution source, ambient air, British thermal unit (Btu), coal, combustion source, continuous..., incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, open burning...

  20. 46 CFR 112.05-5 - Emergency power source.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...

  1. 46 CFR 112.05-5 - Emergency power source.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...

  2. 46 CFR 112.05-5 - Emergency power source.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with § 112.05-1(c). Table 112.05-5(a) Size of vessel and service Type of emergency power source or... power source (automatically connected storage battery or an automatically started generator) 36 hours.1... power source (automatically connected storage battery or an automatically started generator) 8 hours or...

  3. 40 CFR 49.129 - Rule for limiting emissions of sulfur dioxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, open burning, process source, reference method, refuse, residual fuel oil, solid fuel, stack, standard conditions...

  4. 40 CFR 49.129 - Rule for limiting emissions of sulfur dioxide.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, open burning, process source, reference method, refuse, residual fuel oil, solid fuel, stack, standard conditions...

  5. Cortical Spreading Depression Closes Paravascular Space and Impairs Glymphatic Flow: Implications for Migraine Headache

    PubMed Central

    Melo-Carrillo, Agustin; Strassman, Andrew M.

    2017-01-01

    Functioning of the glymphatic system, a network of paravascular tunnels through which cortical interstitial solutes are cleared from the brain, has recently been linked to sleep and traumatic brain injury, both of which can affect the progression of migraine. This led us to investigate the connection between migraine and the glymphatic system. Taking advantage of a novel in vivo method we developed using two-photon microscopy to visualize the paravascular space (PVS) in naive uninjected mice, we show that a single wave of cortical spreading depression (CSD), an animal model of migraine aura, induces a rapid and nearly complete closure of the PVS around surface as well as penetrating cortical arteries and veins lasting several minutes, and gradually recovering over 30 min. A temporal mismatch between the constriction or dilation of the blood vessel lumen and the closure of the PVS suggests that this closure is not likely to result from changes in vessel diameter. We also show that CSD impairs glymphatic flow, as indicated by the reduced rate at which intraparenchymally injected dye was cleared from the cortex to the PVS. This is the first observation of a PVS closure in connection with an abnormal cortical event that underlies a neurological disorder. More specifically, the findings demonstrate a link between the glymphatic system and migraine, and suggest a novel mechanism for regulation of glymphatic flow. SIGNIFICANCE STATEMENT Impairment of brain solute clearance through the recently described glymphatic system has been linked with traumatic brain injury, prolonged wakefulness, and aging. This paper shows that cortical spreading depression, the neural correlate of migraine aura, closes the paravascular space and impairs glymphatic flow. This closure holds the potential to define a novel mechanism for regulation of glymphatic flow. It also implicates the glymphatic system in the altered cortical and endothelial functioning of the migraine brain. PMID:28193695

  6. Cortical Spreading Depression Closes Paravascular Space and Impairs Glymphatic Flow: Implications for Migraine Headache.

    PubMed

    Schain, Aaron J; Melo-Carrillo, Agustin; Strassman, Andrew M; Burstein, Rami

    2017-03-15

    Functioning of the glymphatic system, a network of paravascular tunnels through which cortical interstitial solutes are cleared from the brain, has recently been linked to sleep and traumatic brain injury, both of which can affect the progression of migraine. This led us to investigate the connection between migraine and the glymphatic system. Taking advantage of a novel in vivo method we developed using two-photon microscopy to visualize the paravascular space (PVS) in naive uninjected mice, we show that a single wave of cortical spreading depression (CSD), an animal model of migraine aura, induces a rapid and nearly complete closure of the PVS around surface as well as penetrating cortical arteries and veins lasting several minutes, and gradually recovering over 30 min. A temporal mismatch between the constriction or dilation of the blood vessel lumen and the closure of the PVS suggests that this closure is not likely to result from changes in vessel diameter. We also show that CSD impairs glymphatic flow, as indicated by the reduced rate at which intraparenchymally injected dye was cleared from the cortex to the PVS. This is the first observation of a PVS closure in connection with an abnormal cortical event that underlies a neurological disorder. More specifically, the findings demonstrate a link between the glymphatic system and migraine, and suggest a novel mechanism for regulation of glymphatic flow. SIGNIFICANCE STATEMENT Impairment of brain solute clearance through the recently described glymphatic system has been linked with traumatic brain injury, prolonged wakefulness, and aging. This paper shows that cortical spreading depression, the neural correlate of migraine aura, closes the paravascular space and impairs glymphatic flow. This closure holds the potential to define a novel mechanism for regulation of glymphatic flow. It also implicates the glymphatic system in the altered cortical and endothelial functioning of the migraine brain. Copyright © 2017 the authors 0270-6474/17/372904-12$15.00/0.

  7. [Value of MR imaging and MR angiography in the differential diagnosis of carotid space tumour].

    PubMed

    Liu, Pei-fang; Li, Xin; Bao, Run-xian; Liu, Jing-zu; Ge, Zheng-jin

    2004-04-01

    To determine the imaging features of magnetic resonance imaging (MRI) and 2D time of flight (TOF) MR angiography (MRA) and study the value in the differential diagnosis and surgical planning for carotid space tumors. Twenty-six patients with suspected pulsatile carotid space mass were imaged by MRI and 2D TOF MRA from 1996 to 2003. Its characteristic findings were analyzed for lesion shape, margin, signal intensity, angle of common carotid bifurcation, and the relationship between the great vessels and carotid space mass. Of the 26 patients, 22 were verified histopathologically, including 15 carotid body tumors (1 patient had bilateral carotid body tumors), 4 carotid artery aneurysms, 3 schwannomas, and 1 metastatic carcinoma. The rest four patients had clinical pseudomasses proved by MRI and MRA as considerable dilated or tortuous carotid artery as compared with the contralateral one. Combined MRI and MRA assessment of carotid body tumors and carotid artery aneurysm yielded an accuracy of 100%. It was also revealed that the anatomy shown on the MRI and axial MRA source images was consistent with that found by surgery. MRI in combination with MRA is considered as non-invasive imaging technique for the evaluation of carotid space tumor showing superiority to other modalities in the differential diagnosis between vascular versus non-vascular tumours. This method may take the place of traumatic carotid angiography.

  8. PH adjustment of power plant cooling water with flue gas/fly ash

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2015-09-22

    A system including a vessel including a heat source and a flue; a turbine; a condenser; a fluid conduit circuit disposed between the vessel, the turbine and the condenser; and a diverter coupled to the flue to direct a portion of an exhaust from the flue to contact with a cooling medium for the condenser water. A method including diverting a portion of exhaust from a flue of a vessel; modifying the pH of a cooling medium for a condenser with the portion of exhaust; and condensing heated fluid from the vessel with the pH modified cooling medium.

  9. Degassifying and mixing apparatus for liquids. [potable water for spacecraft

    NASA Technical Reports Server (NTRS)

    Yamauchi, S. T. (Inventor)

    1983-01-01

    An apparatus for degassing a liquid comprises a containment vessel a liquid pump and a header assembly (12) within the containment vessel in a volume above the reservoir of the liquid. The pump draws from this reservoir and outputs to the header assembly, the latter being constructed to return the liquid to the reservoir in the form of a number of stacked, vertically spaced, concentric, conical cascades via orifices. A vacuum source provides a partial vacuum in the containment vessel to enhance the degassing process.

  10. Comparative studies of energy sources in gynecologic laparoscopy.

    PubMed

    Law, Kenneth S K; Lyons, Stephen D

    2013-01-01

    Energy sources incorporating "vessel sealing" capabilities are being increasingly used in gynecologic laparoscopic surgery although conventional monopolar and bipolar electrosurgery remain popular. The preference for one device over another is based on a combination of factors, including the surgeon's subjective experience, availability, and cost. Although comparative clinical studies and meta-analyses of laparoscopic energy sources have reported small but statistically significant differences in volumes of blood loss, the clinical significance of such small volumes is questionable. The overall usefulness of the various energy sources available will depend on a number of factors including vessel burst pressure and seal time, lateral thermal spread, and smoke production. Animal studies and laboratory-based trials are useful in providing a controlled environment to investigate such parameters. At present, there is insufficient evidence to support the use of one energy source over another. Copyright © 2013 AAGL. All rights reserved.

  11. High temperature cooling system and method

    DOEpatents

    Loewen, Eric P.

    2006-12-12

    A method for cooling a heat source, a method for preventing chemical interaction between a vessel and a cooling composition therein, and a cooling system. The method for cooling employs a containment vessel with an oxidizable interior wall. The interior wall is oxidized to form an oxide barrier layer thereon, the cooling composition is monitored for excess oxidizing agent, and a reducing agent is provided to eliminate excess oxidation. The method for preventing chemical interaction between a vessel and a cooling composition involves introducing a sufficient quantity of a reactant which is reactive with the vessel in order to produce a barrier layer therein that is non-reactive with the cooling composition. The cooling system includes a containment vessel with oxidizing agent and reducing agent delivery conveyances and a monitor of oxidation and reduction states so that proper maintenance of a vessel wall oxidation layer occurs.

  12. Safety and clinical efficacy of Onyx for embolization of extracranial head and neck vascular anomalies.

    PubMed

    Thiex, R; Wu, I; Mulliken, J B; Greene, A K; Rahbar, R; Orbach, D B

    2011-01-01

    Onyx was developed for embolization of central nervous system AVMs but is increasingly used extracranially because of its unique physical properties. We review our experience and results with the use of Onyx for the treatment of fast-flow extracranial vascular lesions. We retrospectively analyzed clinical and imaging records of 22 patients who underwent 71 extracranial embolizations from March 2007 through January 2010. The diagnoses were the following: cervicofacial AVM (n = 18), traumatic fistula (n = 3), and vessel laceration (n = 1). In 62 of 71 procedures (87%), Onyx was the sole embolic agent; it was delivered transarterially in 67/71 and percutaneously in 4/71 procedures. Clinical goals included amelioration of pain and control of bleeding. The clinical efficacy of embolization was judged by symptom control, and adverse events were assessed by clinical examination and history, both postembolization and 4 weeks postprocedure. Cessation of acute bleeding was achieved in 13/14 cases, with 1 case of immediate recurrent massive epistaxis prompting reintubation and further embolization. Control of subacute bleeding episodes and pain was achieved for all patients. Following staged embolization, 7 patients underwent surgical resection without significant blood loss. Surgeons reported high satisfaction with the intraoperative handling properties of Onyx. Transient swelling, local tenderness, or numbness was encountered after 7 procedures. There were no stuck catheters, vessel dissections, or vessel ruptures and no skin discoloration. Staged Onyx embolization was clinically efficacious in managing extracranial fast-flow vascular malformations and lesions, with low associated morbidity.

  13. Severe limb ischemia syndrome.

    PubMed

    Suchý, T

    1991-01-01

    In the course of the study of the syndrome of severe limb ischemia (SLI) in a representative clinical material of 300 patients and a number of experimental studies, we arrived to the proposal of this optimal methodical procedure for acute vascular closures of traumatic and non-traumatic origin in the limbs: a) In every injury and sudden pain with a change of the function of the limb, it is necessary to think of the SLI syndrome and to search targetedly for it. b) In injuries connected with bleeding our first-rate task is the control of this bleeding. For a temporary arrest of the bleeding it is necessary to prefer more physiological methods sparing collateral circulation to the still most used tourniquet. For this purpose a new device for temporary hemostasis called Hemostop has proved itself, designed by the author and attested both experimentally and clinically, protected as a Czechoslovak patent. From surgical measures have acquitted themselves from this viewpoint the insertion of vascular clamp, ligature of the vessel or its temporary cannulation. c) To set the diagnosis of SLI, it usually suffices a careful anamnesis and clinical examination, advantageous is the investigation by ultrasound. The angiography because of time consumption should be used only in indicated cases. d) The time factor--"race against the time"--has to be always borne on our mind. It is necessary to achieve the recovery of blood circulation in the limb up to 6 or at the latest up to 10 hours from the onset of injury or closure. e) For shortening of the period of tissue hypoxia it is of advantage to use the temporary cannulation of injured vessels. This should be used always, whenever because of any reasons, it is not possible to execute the final reconstructive operation up to 10 hours since the injury, e. g. in polytraumatism, transport difficulties and the like. f) In isolated vascular injuries without bleeding (about 45%) and in all non-traumatic SLI the patients must be efficiently heparinized (i. v. administration, at best by infusion) to prevent the growth of the distal thrombus. g) Final vascular reconstruction should be performed only by erudited surgeons, always with thromboctomy and in protected coagulum. Optimal reconstructive performance should be chosen: for embolism the thromboembolectomy, for acute thrombosis usually the bypassing the afflicted vascular portion by the graft, in injuries appears as the optimal reconstructive measure the anastomosis end to end. At the simultaneous or isolated lesion of the stem vein, we must always try to reconstruct it.(ABSTRACT TRUNCATED AT 400 WORDS)

  14. Application of 3D printing to prototype and develop novel plant tissue culture systems.

    PubMed

    Shukla, Mukund R; Singh, Amritpal S; Piunno, Kevin; Saxena, Praveen K; Jones, A Maxwell P

    2017-01-01

    Due to the complex process of designing and manufacturing new plant tissue culture vessels through conventional means there have been limited efforts to innovate improved designs. Further, development and availability of low cost, energy efficient LEDs of various spectra has made it a promising light source for plant growth in controlled environments. However, direct replacement of conventional lighting sources with LEDs does not address problems with uniformity, spectral control, or the challenges in conducting statistically valid experiments to assess the effects of light. Prototyping using 3D printing and LED based light sources could help overcome these limitations and lead to improved culture systems. A modular culture vessel design in which the fluence rate and spectrum of light are independently controlled was designed, prototyped using 3D printing, and evaluated for plant growth. This design is compatible with semi-solid and liquid based culture systems. Observations on morphology, chlorophyll content, and chlorophyll fluorescence based stress parameters from in vitro plants cultured under different light spectra with similar overall fluence rate indicated different responses in Nicotiana tabacum and Artemisia annua plantlets. This experiment validates the utility of 3D printing to design and test functional vessels and demonstrated that optimal light spectra for in vitro plant growth is species-specific. 3D printing was successfully used to prototype novel culture vessels with independently controlled variable fluence rate/spectra LED lighting. This system addresses several limitations associated with current lighting systems, providing more uniform lighting and allowing proper replication/randomization for experimental plant biology while increasing energy efficiency. A complete procedure including the design and prototyping of a culture vessel using 3D printing, commercial scale injection molding of the prototype, and conducting a properly replicated experiment are discussed. This open source design has the scope for further improvement and adaptation and demonstrates the power of 3D printing to improve the design of culture systems.

  15. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., gaseous fuel, heat input, incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine..., residual fuel oil, solid fuel, stack, standard conditions, stationary source, uncombined water, used oil...

  16. 40 CFR 49.125 - Rule for limiting the emissions of particulate matter.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., gaseous fuel, heat input, incinerator, marine vessel, mobile sources, motor vehicle, nonroad engine..., residual fuel oil, solid fuel, stack, standard conditions, stationary source, uncombined water, used oil...

  17. 33 CFR 401.73 - Cleaning tanks-hazardous cargo vessels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... gas freeing and tank cleaning has been reported to the nearest Seaway station. (b) Hot work permission. Before any hot work, defined as any work that uses flame or that can produce a source of ignition... prior to the vessel's arrival on SLSMC approach walls or wharfs. The hot work shall not commence until...

  18. 33 CFR 401.73 - Cleaning tanks-hazardous cargo vessels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... gas freeing and tank cleaning has been reported to the nearest Seaway station. (b) Hot work permission. Before any hot work, defined as any work that uses flame or that can produce a source of ignition... prior to the vessel's arrival on SLSMC approach walls or wharfs. The hot work shall not commence until...

  19. 78 FR 47495 - Takes of Marine Mammals Incidental to Specified Activities; Taking Marine Mammals Incidental to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-05

    ... accomplished by one vessel with acoustic sources. Shell plans to conduct site clearance and shallow hazards... equipment recovery and maintenance activity would be accomplished by one vessel operating in dynamic... Wilderness Society (collectively ``AWL''), Bureau of Ocean Energy Management (BOEM), and one private citizen...

  20. 40 CFR Table 1 to Subpart Hhhhh of... - Emission Limits and Work Practice Standards for Process Vessels

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants... to a condenser that reduces the outlet gas temperature to: <10 °C if the process vessel contains HAP...

  1. 26 CFR 31.3306(m)-1 - American vessel and aircraft.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 15 2011-04-01 2011-04-01 false American vessel and aircraft. 31.3306(m)-1 Section 31.3306(m)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... SOURCE Federal Unemployment Tax Act (Chapter 23, Internal Revenue Code of 1954) § 31.3306(m)-1 American...

  2. 26 CFR 31.3306(m)-1 - American vessel and aircraft.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 15 2010-04-01 2010-04-01 false American vessel and aircraft. 31.3306(m)-1 Section 31.3306(m)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... SOURCE Federal Unemployment Tax Act (Chapter 23, Internal Revenue Code of 1954) § 31.3306(m)-1 American...

  3. Mercury Cavitation Phenomenon in Pulsed Spallation Neutron Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Futakawa, Masatoshi; Naoe, Takashi; Kawai, Masayoshi

    2008-06-24

    Innovative researches will be performed at Materials and Life Science Experimental Facility in J-PARC, in which a mercury target system will be installed as MW-class pulse spallation neutron sources. Proton beams will be injected into mercury target to induce the spallation reaction. At the moment the intense proton beam hits the target, pressure waves are generated in the mercury because of the abrupt heat deposition. The pressure waves interact with the target vessel leading to negative pressure that may cause cavitation along the vessel wall. Localized impacts by micro-jets and/or shock waves which are caused by cavitation bubble collapse imposemore » pitting damage on the vessel wall. The pitting damage which degrades the structural integrity of target vessels is a crucial issue for high power mercury targets. Micro-gas-bubbles injection into mercury may be useful to mitigate the pressure wave and the pitting damage. The visualization of cavitation-bubble and gas-bubble collapse behaviors was carried out by using a high-speed video camera. The differences between them are recognized.« less

  4. The Traumatized TFCC: An Illustrated Review of the Anatomy and Injury Patterns of the Triangular Fibrocartilage Complex.

    PubMed

    Skalski, Matthew R; White, Eric A; Patel, Dakshesh B; Schein, Aaron J; RiveraMelo, Hector; Matcuk, George R

    2016-01-01

    The triangular fibrocartilage complex (TFCC) plays an important role in wrist biomechanics and is prone to traumatic and degenerative injury, making it a common source of ulnar-sided wrist pain. Because of this, the TFCC is frequently imaged, and a detailed understanding of its anatomy and injury patterns is critical in generating an accurate report to help guide treatment. In this review, we provide a detailed overview of TFCC anatomy, its normal appearance on magnetic resonance imaging, the spectrum of TFCC injuries based on the Palmer classification system, and pitfalls in accurate assessment. Copyright © 2015 Mosby, Inc. All rights reserved.

  5. Life care planning after traumatic brain injury.

    PubMed

    Zasler, Nathan D; Ameis, Arthur; Riddick-Grisham, Susan N

    2013-08-01

    A life care plan is a detailed and comprehensive analysis of impairments, realistic needs, and associated costs relevant to providing a lifetime of care to patients. Physicians have a central role in advising life care planners. Within an expertly prepared life care plan, issues must correspond directly with proposed goods and services. A life care plan must clearly cite all relevant caregiver sources and rely on scientific evidence. The central tenets of a life care plan and the ethical and professional roles that physicians may play in the context of traumatic brain injury and a life care plan are reviewed in this article. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. New York City social workers after 9/11: their attachment, resiliency, and compassion fatigue.

    PubMed

    Tosone, Carol; Bettmann, Joanna E; Minami, Takuya; Jasperson, Rachael A

    2010-01-01

    This study examines the relationship between attachment classification, resiliency, and compassion fatigue in New York social workers following 9/11. We used single occasion, quasi-random sampling, surveying 481 social workers living in Manhattan. Hierarchical regression analyses revealed that secure attachment is predictive of the ability to cope with secondary traumatic stress as well as capacity for resilience, explaining approximately 7% of the variance in both compassion fatigue and resiliency. These findings suggest that secure attachment may serve as a source of resilience for social workers, immunizing them from significant compassion fatigue. Such findings have significant implications for clinicians working with traumatized populations.

  7. 46 CFR 129.310 - Power sources.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power sources. 129.310 Section 129.310 Shipping COAST... Power Sources and Distribution Systems § 129.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from at least two...

  8. 46 CFR 129.310 - Power sources.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Power Sources and Distribution Systems § 129.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from at least two... 46 Shipping 4 2011-10-01 2011-10-01 false Power sources. 129.310 Section 129.310 Shipping COAST...

  9. 46 CFR 129.310 - Power sources.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Power Sources and Distribution Systems § 129.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from at least two... 46 Shipping 4 2014-10-01 2014-10-01 false Power sources. 129.310 Section 129.310 Shipping COAST...

  10. 46 CFR 129.310 - Power sources.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Power Sources and Distribution Systems § 129.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from at least two... 46 Shipping 4 2012-10-01 2012-10-01 false Power sources. 129.310 Section 129.310 Shipping COAST...

  11. 46 CFR 129.310 - Power sources.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Power Sources and Distribution Systems § 129.310 Power sources. (a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from at least two... 46 Shipping 4 2013-10-01 2013-10-01 false Power sources. 129.310 Section 129.310 Shipping COAST...

  12. Current Methodologies in Preparing Mobile Source Port-Related Emission Inventories Final Report April 2009

    EPA Pesticide Factsheets

    This report focuses on mobile emission sources at ports, including oceangoing vessels (OGVs), harbor craft, and cargo handling equipment (CHE), as well as other land-side mobile emission sources at ports, such as locomotives and on-highway vehicles.

  13. Development of the front end test stand and vessel for extraction and source plasma analyses negative hydrogen ion sources at the Rutherford Appleton Laboratory.

    PubMed

    Lawrie, S R; Faircloth, D C; Letchford, A P; Perkins, M; Whitehead, M O; Wood, T; Gabor, C; Back, J

    2014-02-01

    The ISIS pulsed spallation neutron and muon facility at the Rutherford Appleton Laboratory (RAL) in the UK uses a Penning surface plasma negative hydrogen ion source. Upgrade options for the ISIS accelerator system demand a higher current, lower emittance beam with longer pulse lengths from the injector. The Front End Test Stand is being constructed at RAL to meet the upgrade requirements using a modified ISIS ion source. A new 10% duty cycle 25 kV pulsed extraction power supply has been commissioned and the first meter of 3 MeV radio frequency quadrupole has been delivered. Simultaneously, a Vessel for Extraction and Source Plasma Analyses is under construction in a new laboratory at RAL. The detailed measurements of the plasma and extracted beam characteristics will allow a radical overhaul of the transport optics, potentially yielding a simpler source configuration with greater output and lifetime.

  14. 40 CFR 63.760 - Applicability and designation of affected source.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) of this section. (i) Each glycol dehydration unit; (ii) Each storage vessel with the potential for... affected source includes each triethylene glycol (TEG) dehydration unit located at a facility that meets...

  15. 40 CFR 63.760 - Applicability and designation of affected source.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) of this section. (i) Each glycol dehydration unit; (ii) Each storage vessel with the potential for... affected source includes each triethylene glycol (TEG) dehydration unit located at a facility that meets...

  16. 40 CFR 63.760 - Applicability and designation of affected source.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) of this section. (i) Each glycol dehydration unit; (ii) Each storage vessel with the potential for... affected source includes each triethylene glycol (TEG) dehydration unit located at a facility that meets...

  17. 40 CFR 49.130 - Rule for limiting sulfur in fuels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fuels that are burned at stationary sources within the Indian reservation to control emissions of sulfur..., gaseous fuel, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, owner or...

  18. 40 CFR 49.130 - Rule for limiting sulfur in fuels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... burned at stationary sources within the Indian reservation to control emissions of sulfur dioxide (SO2..., gaseous fuel, marine vessel, mobile sources, motor vehicle, nonroad engine, nonroad vehicle, owner or...

  19. Development of gas pulsing system for electron cyclotron resonance ion source.

    PubMed

    Hojo, S; Honma, T; Muramatsu, M; Sakamoto, Y; Sugiura, A

    2008-02-01

    A gas-pulsing system for an electron cyclotron resonance ion source with all permanent magnets (Kei2 source) at NIRS has been developed and tested. The system consists of a small vessel (30 ml) to reserve CH(4) gas and two fast solenoid valves that are installed at both sides of the vessel. They are connected to each other and to the Kei2 source by using a stainless-steel pipe (4 mm inner diameter), where the length of the pipe from the valve to the source is 60 cm and the conductance is 1.2 l/s. From the results of the test, almost 300 e microA for a pulsed (12)C(4+) beam was obtained at a Faraday cup in an extraction-beam channel with a pressure range of 4000 Pa in the vessel. At this time, the valve has an open time of 10 ms and the delay time between the valve open time and the application of microwave power is 100 ms. In experiments, the conversion efficiency for input CH(4) molecules to the quantity of extracted (12)C(4+) ions in one beam pulse was found to be around 3% and the ratio of the total amount of the gas requirement was only 10% compared with the case of continuous gas provided in 3.3 s of repetition in HIMAC.

  20. Endovascular treatment for traumatic scalp arteriovenous fistulas: results with Onyx embolization.

    PubMed

    Dabus, Guilherme; Pizzolato, Raffaella; Lin, Eugene; Kreusch, Andreas; Linfante, Italo

    2014-06-01

    Arteriovenous fistulas of the scalp (S-AVFs) are rare lesions and may occur spontaneously or secondary to trauma. The use of Onyx for the treatment of S-AVFs is not well established at this time. We discuss three cases of traumatic S-AVFs treated successfully with Onyx embolization alone or in association with coils. The database of patients treated at the Baptist Cardiac and Vascular Institute, Miami, Florida, was reviewed. All patients with traumatic S-AVFs treated with Onyx were included. Two men and one woman with progressive enlarging pulsatile mass with bruit or tinnitus had angiographic evidence of S-AVF and were treated. In two patients the S-AVFs were secondary to hair transplantation. They were treated with Onyx-18 embolization as the single treatment modality. One patient with S-AVF resulting from temporomandibular joint arthroscopy was treated with coils and subsequent Onyx-34 embolization. In one patient, transarterial microcatheterization and injection of Onyx-18 was performed. In another patient, the intra-arterial approach was prevented by arterial vessel tortuosity. Therefore, access to the fistula was obtained through direct puncture of a large frontal vein; contrast injection confirmed the positioning of the needle within the draining vein of the AVF and Onyx-18 was then injected while the outflow vein was compressed. In the third patient in this series, coils were deployed to allow safer and more controlled injection of Onyx-34. No procedure related complications were noted. Post-embolization angiography demonstrated successful and complete occlusion of the AVF immediately after treatment. Follow-up revealed complete resolution of the symptoms. Our experience in this small series indicates that endovascular treatment of S-AVFs with Onyx is rapid, safe, and highly effective.

  1. Patterns of Injury Among Drivers Hospitalized in Level-I Trauma Centers: Have Frontal Airbags Made a Difference?

    PubMed Central

    Segui-Gomez, Maria; Graham, John D.

    2000-01-01

    This study describes the injuries of drivers discharged from Level-I Trauma Centers between 1995–1997. Differences in the drivers’ injuries and outcomes by airbag deployment status and gender were evaluated using Chi2 and T-tests. Data on 1,065 drivers (66 with airbags, 423 females) were obtained from the Massachusetts Registry of Motor Vehicle and Trauma Registries. Once admitted to trauma centers, drivers with airbags did not differ from drivers without airbags regarding the number, type, clustering, severity or outcome of their injuries. The only exception was that female drivers sustained more fractures to the upper extremities and less injuries to blood vessels and certain traumatic complications (p<0.05). PMID:11558082

  2. Smartphones and dental trauma: the current availability of apps for managing traumatic dental injuries.

    PubMed

    Djemal, Serpil; Singh, Parmjit

    2016-02-01

    There is a general consensus regarding the lack of awareness regarding the emergency management of traumatic dental injuries amongst laypersons and dental professionals. This article aims to provide an overview of the apps available for traumatic dental injuries using smartphones. These apps may serve as a gateway for raising awareness of traumatic dental injuries. Three smartphone devices were used to access their respective app stores (Nokia Lumia 635 with Windows Phone OS 8.1; iPhone 5 with iOS 8.1; Samsung Galaxy Ace II with Android OS v2.3.6 Gingerbread). Nine phrases were searched: broken tooth/teeth; chipped tooth/teeth; dental emergency; dental injury; dental trauma; fractured tooth/teeth; knocked-out tooth/teeth; tooth/teeth injury; and tooth/teeth trauma. Seven apps for the Android and one app for the Apple operating system were relevant. The only Apple iOS app retrieved (Dental Trauma) was also found for the Android OS (Dental Trauma First Aid) and had the endorsement of the International Association of Dental Traumatology. AcciDent was the only app dedicated to traumatic dental injuries targeted solely towards dental professionals. Five other apps (Chipped Tooth Solution, Dental Crown Repair, Fixing Cracked Tooth, Repairing the Front Tooth and Solution to Broken Tooth) appeared to come from the same source (KBES). No traumatic dental injury apps were found for the Windows Phone OS. There are apps available for both patients and dentists that range in quality and on the whole lack real-life photographs. Future apps should continue to provide good quality, evidence-based and validated material. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Anatomical study of the accessory axillary vein in cadavers: a contribution to the axillary surgical approach.

    PubMed

    Felix, Valtuir Barbosa; Dos Santos, José André Bernardino; Fernandes, Katharina Jucá de Moraes; Cabral, Dhayanna Rolemberg Gama; Dos Santos, Carlos Adriano Silva; Rodrigues, Célio Fernando de Sousa; Lima, Jacqueline Silva Brito; Ramalho, Antônio José Casado

    2016-01-01

    The axillary vein is an important blood vessel that participates in drainage of the upper limb. Some individuals present a second axillary vein (accessory axillary vein), which is an important collateral drainage path. The goal of this study was to determine the incidence of the accessory axillary vein and to describe this vessel's topography. In this study, axillary dissections were carried out on twenty-four (24) human cadavers of both sexes that had been fixed with 10% formaldehyde. The upper limbs of the cadavers were still attached to the bodies and the axillary structures were preserved. Data collection was carried out and the axillary structures of the cadavers were compared. The incidence of accessory axillary veins was 58.3%, with no significant preference for sex or for side of the body. The accessory axillary vein originated from the lateral brachial vein in 39.28% of cases, from the common brachial vein in 35.71% of cases, and from the deep brachial vein in 25% of cases. Its high incidence and clinical relevance make the accessory axillary vein important for provision of collateral circulation in the event of traumatic injury to the axillary vein.

  4. Discontinuity stresses in metallic pressure vessels

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The state of the art, criteria, and recommended practices for the theoretical and experimental analyses of discontinuity stresses and their distribution in metallic pressure vessels for space vehicles are outlined. The applicable types of pressure vessels include propellant tanks ranging from main load-carrying integral tank structure to small auxiliary tanks, storage tanks, solid propellant motor cases, high pressure gas bottles, and pressurized cabins. The major sources of discontinuity stresses are discussed, including deviations in geometry, material properties, loads, and temperature. The advantages, limitations, and disadvantages of various theoretical and experimental discontinuity analysis methods are summarized. Guides are presented for evaluating discontinuity stresses so that pressure vessel performance will not fall below acceptable levels.

  5. Intracranial MRA: single volume vs. multiple thin slab 3D time-of-flight acquisition.

    PubMed

    Davis, W L; Warnock, S H; Harnsberger, H R; Parker, D L; Chen, C X

    1993-01-01

    Single volume three-dimensional (3D) time-of-flight (TOF) MR angiography is the most commonly used noninvasive method for evaluating the intracranial vasculature. The sensitivity of this technique to signal loss from flow saturation limits its utility. A recently developed multislab 3D TOF technique, MOTSA, is less affected by flow saturation and would therefore be expected to yield improved vessel visualization. To study this hypothesis, intracranial MR angiograms were obtained on 10 volunteers using three techniques: MOTSA, single volume 3D TOF using a standard 4.9 ms TE (3D TOFA), and single volume 3D TOF using a 6.8 ms TE (3D TOFB). All three sets of axial source images and maximum intensity projection (MIP) images were reviewed. Each exam was evaluated for the number of intracranial vessels visualized. A total of 502 vessel segments were studied with each technique. With use of the MIP images, 86% of selected vessels were visualized with MOTSA, 64% with 3D TOFA (TE = 4.9 ms), and 67% with TOFB (TE = 6.8 ms). Similarly, with the axial source images, 91% of selected vessels were visualized with MOTSA, 77% with 3D TOFA (TE = 4.9 ms), and 82% with 3D TOFB (TE = 6.8 ms). There is improved visualization of selected intracranial vessels in normal volunteers with MOTSA as compared with single volume 3D TOF. These improvements are believed to be primarily a result of decreased sensitivity to flow saturation seen with the MOTSA technique. No difference in overall vessel visualization was noted for the two single volume 3D TOF techniques.

  6. A pilot study to image the vascular network of small melanocytic choroidal tumors with speckle noise-free 1050-nm swept source optical coherence tomography (OCT choroidal angiography).

    PubMed

    Maloca, Peter; Gyger, Cyrill; Hasler, Pascal W

    2016-06-01

    To visualize and measure the vascular network of melanocytic choroidal tumors with speckle noise-free swept source optical coherence tomography (SS-OCT choroidal angiography). Melanocytic choroidal tumors from 24 eyes were imaged with 1050-nm optical coherence tomography (Topcon DRI OCT-1 Atlantis). A semi-automated algorithm was developed to remove speckle noise and to extract and measure the volume of the choroidal vessels from the obtained OCT data. In all cases, analysis of the choroidal vessels could be performed with SS-OCT without the need for pupillary dilation. The proposed method allows speckle noise-free, structure-guided visualization and measurement of the larger choroidal vessels in three dimensions. The obtained data suggest that speckle noise-free OCT may be more effective at identifying choroidal structures than traditional OCT methods. The measured volume of the extracted choroidal vessels of Haller's layer and Sattler's layer in the examined tumorous eyes was on average 0.982463955 mm(3) /982463956 μm(3) (range of 0.209764406 mm(3) /209764405.9 μm(3)to 1.78105544 mm(3) /1781055440 μm(3)). Full thickness obstruction of the choroidal vasculature by the tumor was found in 18 cases (72 %). In seven cases (18 %), choroidal vessel architecture did not show pronounced morphological abnormalities (18 %). Speckle noise-free OCT may serve as a new illustrative imaging technology and enhance visualization of the choroidal vessels without the need for dye injection. OCT can be used to identify and evaluate the choroidal vessels of melanocytic choroidal tumors, and may represent a potentially useful tool for imaging and monitoring of choroidal nevi and melanoma.

  7. Explosive vessel for coupling dynamic experiments to the X-ray beam at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Owens, Charles; Sanchez, Nathaniel; Sorensen, Christian; Jensen, Brian

    2017-06-01

    Recent experiments at the Advanced Photon Source have been successful in coupling gun systems to the synchrotron to take advantage of the advanced X-ray diagnostics available including X-ray diffraction and X-ray phase contrast imaging (PCI) to examine matter at extreme conditions. There are many experiments that require explosive loading capabilities, e.g. detonator and initiator dynamics, small angle X-ray scattering (SAXS), ejecta formation, and explosively driven flyer experiments. The current work highlights a new explosive vessel that was designed specifically for use at a synchrotron facility with requirements to confine up to 15 grams of explosives (TNT equivalent), couple the vessel to the X-ray beam line, and reliably position samples remotely. A description of the system and capability will be provided along with the results from qualification testing to bring the system into service (LA-UR-17-21381).

  8. Synergic nitrogen source route to inorganic fullerene-like boron nitride with vessel, hollow sphere, onion, and peanut nanostructures.

    PubMed

    Xu, Fen; Xie, Yi; Zhang, Xu; Zhang, Shuyuan; Liu, Xianming; Tian, Xiaobo

    2004-01-26

    In this paper we describe the large-scale synthesis of inorganic fullerene-like (IF-like) hexagonal boron nitride with vessel, hollow sphere, peanut, and onion structures by reacting BBr(3) with the synergic nitrogen sources NaNH(2) and NH(4)Cl at 400-450 degrees C for 6-12 h. The composition of products could be confirmed to be pure boron nitride with hexagonal structures by the XRD patterns and FT-IR, XPS, and EDXA spectra. The representative HRTEM images clearly reveal the layerlike features of the products. Here, the peanut-like structure of the IF-like BN is reported for the first time, and added to the list as one kind of new morphology of BN nanomaterials. The similarity in the structure between h-BN and graphite is responsible for the formation of IF-like BN with nanostructures of vessels, hollow spheres, peanuts, and onions.

  9. A traumatic hepatic artery pseudoaneurysm and arterioportal fistula, with severe diarrhea as the first symptom: A case report and review of the literature.

    PubMed

    Han, Ping; Yang, Lan; Huang, Xiao-Wei; Zhu, Xiu-Qin; Chen, Li; Wang, Nan; Li, Zhen; Tian, De-An; Qin, Hua

    2018-02-01

    Hepaticarterioportal fistula (APF) is a rare cause of portal hypertension and gastrointestinal hemorrhage, and presents as abnormal communication between the hepatic artery and portal vein. Percutaneous liver biopsy is a main iatrogenic cause of AFP. However, non-iatrogenic, abdominal, trauma-related APF is rarely reported. A 29-year-old man presenting with severe, watery diarrhea was transferred to our hospital, and his condition was suspected to be acute gastroenteritis because he ate expired food and suffered a penetrating abdominal stab wound 5 years ago. After admission, the patient suffered from hematemesis, hematochezia, ascites, anuria, and kidney failure, and he developed shock. The patient was finally diagnosed as a traumatic hepatic artery pseudoaneurysm and APF. This patient was treated with emergency transarterial embolization using coils. Since a secondary feeding vessel was exposed after the first embolization of the main feeding artery, a less-selective embolization was performed again. During the 6-month follow-up period, the patient remained asymptomatic. A penetrating abdominal stab wound is a rare cause of hepatic APFs, and occasionally leads to portal hypertension, the medical history and physical examination are the most important cornerstones of clinical diagnosis. Interventional radiology is essential for the diagnosis and treatment of an APF.

  10. A traumatic hepatic artery pseudoaneurysm and arterioportal fistula, with severe diarrhea as the first symptom

    PubMed Central

    Han, Ping; Yang, Lan; Huang, Xiao-Wei; Zhu, Xiu-Qin; Chen, Li; Wang, Nan; Li, Zhen; Tian, De-An; Qin, Hua

    2018-01-01

    Abstract Rationale: Hepaticarterioportal fistula (APF) is a rare cause of portal hypertension and gastrointestinal hemorrhage, and presents as abnormal communication between the hepatic artery and portal vein. Percutaneous liver biopsy is a main iatrogenic cause of AFP. However, non-iatrogenic, abdominal, trauma-related APF is rarely reported. Patient concerns: A 29-year-old man presenting with severe, watery diarrhea was transferred to our hospital, and his condition was suspected to be acute gastroenteritis because he ate expired food and suffered a penetrating abdominal stab wound 5 years ago. After admission, the patient suffered from hematemesis, hematochezia, ascites, anuria, and kidney failure, and he developed shock. Diagnoses: The patient was finally diagnosed as a traumatic hepatic artery pseudoaneurysm and APF. Interventions: This patient was treated with emergency transarterial embolization using coils. Since a secondary feeding vessel was exposed after the first embolization of the main feeding artery, a less-selective embolization was performed again. Outcomes: During the 6-month follow-up period, the patient remained asymptomatic. Lessons: A penetrating abdominal stab wound is a rare cause of hepatic APFs, and occasionally leads to portal hypertension, the medical history and physical examination are the most important cornerstones of clinical diagnosis. Interventional radiology is essential for the diagnosis and treatment of an APF. PMID:29443759

  11. Optical microangiography enabling visualization of change in meninges after traumatic brain injury in mice in vivo

    NASA Astrophysics Data System (ADS)

    Choi, Woo June; Qin, Wan; Qi, Xiaoli; Wang, Ruikang K.

    2016-03-01

    Traumatic brain injury (TBI) is a form of brain injury caused by sudden impact on brain by an external mechanical force. Following the damage caused at the moment of injury, TBI influences pathophysiology in the brain that takes place within the minutes or hours involving alterations in the brain tissue morphology, cerebral blood flow (CBF), and pressure within skull, which become important contributors to morbidity after TBI. While many studies for the TBI pathophysiology have been investigated with brain cortex, the effect of trauma on intracranial tissues has been poorly studied. Here, we report use of high-resolution optical microangiography (OMAG) to monitor the changes in cranial meninges beneath the skull of mouse after TBI. TBI is induced on a brain of anesthetized mouse by thinning the skull using a soft drill where a series of drilling exert mechanical stress on the brain through the skull, resulting in mild brain injury. Intracranial OMAG imaging of the injured mouse brain during post-TBI phase shows interesting pathophysiological findings in the meningeal layers such as widening of subdural space as well as vasodilation of subarachnoid vessels. These processes are acute and reversible within hours. The results indicate potential of OMAG to explore mechanism involved following TBI on small animals in vivo.

  12. Traumatic Brain Injury Causes Endothelial Dysfunction in the Systemic Microcirculation through Arginase-1-Dependent Uncoupling of Endothelial Nitric Oxide Synthase.

    PubMed

    Villalba, Nuria; Sackheim, Adrian M; Nunez, Ivette A; Hill-Eubanks, David C; Nelson, Mark T; Wellman, George C; Freeman, Kalev

    2017-01-01

    Endothelial dysfunction is a hallmark of many chronic diseases, including diabetes and long-term hypertension. We show that acute traumatic brain injury (TBI) leads to endothelial dysfunction in rat mesenteric arteries. Endothelial-dependent dilation was greatly diminished 24 h after TBI because of impaired nitric oxide (NO) production. The activity of arginase, which competes with endothelial NO synthase (eNOS) for the common substrate l-arginine, were also significantly increased in arteries, suggesting that arginase-mediated depletion of l-arginine underlies diminished NO production. Consistent with this, substrate restoration by exogenous application of l-arginine or inhibition of arginase recovered endothelial function. Moreover, evidence for increased reactive oxygen species production, a consequence of l-arginine starvation-dependent eNOS uncoupling, was detected in endothelium and plasma. Collectively, our findings demonstrate endothelial dysfunction in a remote vascular bed after TBI, manifesting as impaired endothelial-dependent vasodilation, with increased arginase activity, decreased generation of NO, and increased O 2 - production. We conclude that blood vessels have a "molecular memory" of neurotrauma, 24 h after injury, because of functional changes in vascular endothelial cells; these effects are pertinent to understanding the systemic inflammatory response that occurs after TBI even in the absence of polytrauma.

  13. Dating of Traumatic Brain Injury in Forensic Cases Using Immunohistochemical Markers (I): Neurofilaments and β-Amyloid Precursor Protein.

    PubMed

    Romero Tirado, María de Los Ángeles; Blanco Pampin, José Manuel; Gallego Gómez, Rosalía

    2018-06-13

    Studies about head trauma are experimental or have a clinical or prognosis purpose. In this study, we used samples from human autopsies to answer common medical-legal questions.We studied 21 problem cases and 4 controls. Samples were obtained directly from the injured area, fixed in 10% formalin during 24 hours and then preserved in 70% ethanol. This procedure optimizes the immunohistochemical technique.The neurofilament antibody shows beaded axons since the first moment; over time, they increase their density and diameter as survival time also increases. These changes begin in the gray matter, 2 hours after trauma can be seen around vessels and in hemorrhagic areas. At 24 hours, beaded axons appear in the white mater, which finally loses its structure and cellular density.On the other hand, the β-amyloid precursor protein marker begins to be weakly seen 2 hours after injury. At 24 hours, a diffuse pattern can appear, suggesting primary traumatic injury. The marker reading keeps increasing until day 26, when a "Z" pattern appears in the white matter, suggesting secondary hypoxic injury.All these chronologic changes could be useful to approach the date of trauma. They let us to distinguish between long surviving cases from those whose death was immediate (within the first 30 minutes).

  14. Characterizing large river sounds: Providing context for understanding the environmental effects of noise produced by hydrokinetic turbines

    DOE PAGES

    Bevelhimer, Mark S.; Deng, Z. Daniel; Scherelis, Constantin C.

    2016-01-06

    Underwaternoise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels and natural underwater sound sources in static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines on the Mississippi River, where soundsmore » created by flowing water are part of all measurements, both natural ambient and anthropogenic sources. Vessel sizes ranged from a small fishing boat with 60 hp outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, which were, on average, 40 dB greater than the sound created by an operating hydrokinetic turbine. As a result, a comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed sound attenuation.« less

  15. Characterizing large river sounds: Providing context for understanding the environmental effects of noise produced by hydrokinetic turbines.

    PubMed

    Bevelhimer, Mark S; Deng, Z Daniel; Scherelis, Constantin

    2016-01-01

    Underwater noise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels and natural underwater sound sources in static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines on the Mississippi River, where sounds created by flowing water are part of all measurements, both natural ambient and anthropogenic sources. Vessel sizes ranged from a small fishing boat with 60 hp outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, which were, on average, 40 dB greater than the sound created by an operating hydrokinetic turbine. A comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed sound attenuation.

  16. Computer-Aided Thermohydraulic Design of TEMA Type E Shell and Tube Heat Exchangers for Use in Low Pressure, Liquid-to-Liquid, Single Phase Applications.

    DTIC Science & Technology

    1985-04-01

    and Standards .. ... ....... ....... 9 A. General . ... .. .. ... ..... .. .. ... 9 B. ASME Boiler and Pressure Vessel Code .. .. ......9 C. Foreign...several different sources. B. American Society of Mechanial Engineers (ASME) Boiler and Pressure Vessel Code A shell and tube heat exchanger is indeed a

  17. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation... means of ventilation. (b) Compartments containing machinery where sources of vapor ignition are normally... approved for this purpose. Machinery spaces below the freeboard deck, in which fuels with flash point of...

  18. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation... means of ventilation. (b) Compartments containing machinery where sources of vapor ignition are normally... approved for this purpose. Machinery spaces below the freeboard deck, in which fuels with flash point of...

  19. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation... means of ventilation. (b) Compartments containing machinery where sources of vapor ignition are normally... approved for this purpose. Machinery spaces below the freeboard deck, in which fuels with flash point of...

  20. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation... means of ventilation. (b) Compartments containing machinery where sources of vapor ignition are normally... approved for this purpose. Machinery spaces below the freeboard deck, in which fuels with flash point of...

  1. 46 CFR 32.55-1 - Ventilation of tank vessels constructed on or after July 1, 1951-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS Ventilation and Venting § 32.55-1 Ventilation... means of ventilation. (b) Compartments containing machinery where sources of vapor ignition are normally... approved for this purpose. Machinery spaces below the freeboard deck, in which fuels with flash point of...

  2. Toward a Mechanistic Source Term in Advanced Reactors: Characterization of Radionuclide Transport and Retention in a Sodium Cooled Fast Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunett, Acacia J.; Bucknor, Matthew; Grabaskas, David

    A vital component of the U.S. reactor licensing process is an integrated safety analysis in which a source term representing the release of radionuclides during normal operation and accident sequences is analyzed. Historically, source term analyses have utilized bounding, deterministic assumptions regarding radionuclide release. However, advancements in technical capabilities and the knowledge state have enabled the development of more realistic and best-estimate retention and release models such that a mechanistic source term assessment can be expected to be a required component of future licensing of advanced reactors. Recently, as part of a Regulatory Technology Development Plan effort for sodium cooledmore » fast reactors (SFRs), Argonne National Laboratory has investigated the current state of knowledge of potential source terms in an SFR via an extensive review of previous domestic experiments, accidents, and operation. As part of this work, the significant sources and transport processes of radionuclides in an SFR have been identified and characterized. This effort examines all stages of release and source term evolution, beginning with release from the fuel pin and ending with retention in containment. Radionuclide sources considered in this effort include releases originating both in-vessel (e.g. in-core fuel, primary sodium, cover gas cleanup system, etc.) and ex-vessel (e.g. spent fuel storage, handling, and movement). Releases resulting from a primary sodium fire are also considered as a potential source. For each release group, dominant transport phenomena are identified and qualitatively discussed. The key product of this effort was the development of concise, inclusive diagrams that illustrate the release and retention mechanisms at a high level, where unique schematics have been developed for in-vessel, ex-vessel and sodium fire releases. This review effort has also found that despite the substantial range of phenomena affecting radionuclide release, the current state of knowledge is extensive, and in most areas may be sufficient. Several knowledge gaps were identified, such as uncertainty in release from molten fuel and availability of thermodynamic data for lanthanides and actinides in liquid sodium. However, the overall findings suggest that high retention rates can be expected within the fuel and primary sodium for all radionuclides other than noble gases.« less

  3. Thromboelastographic evidence of inhibition of fibrinolysis after ε-aminocaproic acid administration in a dog with suspected acute traumatic coagulopathy.

    PubMed

    Yoo, Seung H; Venn, Emilee; Sullivan, Lauren A; Olver, Christine S

    2016-09-01

    To describe the thromboelastographic changes in fibrinolysis with ε-aminocaproic acid treatment in a dog with suspected acute traumatic coagulopathy. A 9-year-old female spayed Airedale Terrier was presented with multiple injuries consistent with motor vehicle trauma. After surgical repair of a diaphragmatic hernia and minor laceration of the right cranial lung lobe, the dog continued to produce copious volumes of hemorrhagic fluid from the thoracic cavity despite multiple plasma transfusions, autotransfusions, and failure to locate a definitive source of bleeding during 2 separate surgeries. ε-Aminocaproic acid treatment was initiated and was associated with rapid clinical improvement and diminished fibrinolysis based on a modified plasma-based thromboelastogram. This report describes thromboelastographic evidence of inhibition of fibrinolysis after ε-aminocaproic acid administration in a dog with suspected acute traumatic coagulopathy. Thromboelastrography may be useful in monitoring therapy with antifibrinolytic drugs. © Veterinary Emergency and Critical Care Society 2016.

  4. METHODOLOGIES FOR ESTIMATING AIR EMISSIONS FROM THREE NON-TRADITIONAL SOURCE CATEGORIES: OIL SPILLS, PETROLEUM VESSEL LOADING & UNLOADING, AND COOLING TOWERS

    EPA Science Inventory

    The report discusses part of EPA's program to identify and characterize emissions sources not currently accounted for by either the existing Aerometric Information Retrieval System (AIRS) or State Implementation Plan (sip) area source methodologies and to develop appropriate emis...

  5. Line-of-sight deposition method

    DOEpatents

    Patten, J.W.; McClanahan, E.D.; Bayne, M.A.

    1980-04-16

    A line-of-sight method of depositing a film having substantially 100% of theoretical density on a substrate. A pressure vessel contains a target source having a surface thereof capable of emitting particles therefrom and a substrate with the source surface and the substrate surface positioned such that the source surface is substantially parallel to the direction of the particles impinging upon the substrate surface, the distance between the most remote portion of the substrate surface receiving the particles and the source surface emitting the particles in a direction parallel to the substrate surface being relatively small. The pressure in the vessel is maintained less than about 5 microns to prevent scattering and permit line-of-sight deposition. By this method the angles of incidence of the particles impinging upon the substrate surface are in the range of from about 45/sup 0/ to 90/sup 0/ even when the target surface area is greatly expanded to increase the deposition rate.

  6. Line-of-sight deposition method

    DOEpatents

    Patten, James W.; McClanahan, Edwin D.; Bayne, Michael A.

    1981-01-01

    A line-of-sight method of depositing a film having substantially 100% of theoretical density on a substrate. A pressure vessel contains a target source having a surface thereof capable of emitting particles therefrom and a substrate with the source surface and the substrate surface positioned such that the source surface is substantially parallel to the direction of the particles impinging upon the substrate surface, the distance between the most remote portion of the substrate surface receiving the particles and the source surface emitting the particles in a direction parallel to the substrate surface being relatively small. The pressure in the vessel is maintained less than about 5 microns to prevent scattering and permit line-of-sight deposition. By this method the angles of incidence of the particles impinging upon the substrate surface are in the range of from about 45.degree. to 90.degree. even when the target surface area is greatly expanded to increase the deposition rate.

  7. Harbour porpoises react to low levels of high frequency vessel noise

    PubMed Central

    Dyndo, Monika; Wiśniewska, Danuta Maria; Rojano-Doñate, Laia; Madsen, Peter Teglberg

    2015-01-01

    Cetaceans rely critically on sound for navigation, foraging and communication and are therefore potentially affected by increasing noise levels from human activities at sea. Shipping is the main contributor of anthropogenic noise underwater, but studies of shipping noise effects have primarily considered baleen whales due to their good hearing at low frequencies, where ships produce most noise power. Conversely, the possible effects of vessel noise on small toothed whales have been largely ignored due to their poor low-frequency hearing. Prompted by recent findings of energy at medium- to high-frequencies in vessel noise, we conducted an exposure study where the behaviour of four porpoises (Phocoena phocoena) in a net-pen was logged while they were exposed to 133 vessel passages. Using a multivariate generalised linear mixed-effects model, we show that low levels of high frequency components in vessel noise elicit strong, stereotyped behavioural responses in porpoises. Such low levels will routinely be experienced by porpoises in the wild at ranges of more than 1000 meters from vessels, suggesting that vessel noise is a, so far, largely overlooked, but substantial source of disturbance in shallow water areas with high densities of both porpoises and vessels. PMID:26095689

  8. Absolute probability estimates of lethal vessel strikes to North Atlantic right whales in Roseway Basin, Scotian Shelf.

    PubMed

    van der Hoop, Julie M; Vanderlaan, Angelia S M; Taggart, Christopher T

    2012-10-01

    Vessel strikes are the primary source of known mortality for the endangered North Atlantic right whale (Eubalaena glacialis). Multi-institutional efforts to reduce mortality associated with vessel strikes include vessel-routing amendments such as the International Maritime Organization voluntary "area to be avoided" (ATBA) in the Roseway Basin right whale feeding habitat on the southwestern Scotian Shelf. Though relative probabilities of lethal vessel strikes have been estimated and published, absolute probabilities remain unknown. We used a modeling approach to determine the regional effect of the ATBA, by estimating reductions in the expected number of lethal vessel strikes. This analysis differs from others in that it explicitly includes a spatiotemporal analysis of real-time transits of vessels through a population of simulated, swimming right whales. Combining automatic identification system (AIS) vessel navigation data and an observationally based whale movement model allowed us to determine the spatial and temporal intersection of vessels and whales, from which various probability estimates of lethal vessel strikes are derived. We estimate one lethal vessel strike every 0.775-2.07 years prior to ATBA implementation, consistent with and more constrained than previous estimates of every 2-16 years. Following implementation, a lethal vessel strike is expected every 41 years. When whale abundance is held constant across years, we estimate that voluntary vessel compliance with the ATBA results in an 82% reduction in the per capita rate of lethal strikes; very similar to a previously published estimate of 82% reduction in the relative risk of a lethal vessel strike. The models we developed can inform decision-making and policy design, based on their ability to provide absolute, population-corrected, time-varying estimates of lethal vessel strikes, and they are easily transported to other regions and situations.

  9. Non-traumatic and spontaneous hemothorax in the setting of forensic medical examination: a systematic literature survey.

    PubMed

    Janik, Martin; Straka, Lubomir; Krajcovic, Jozef; Hejna, Petr; Hamzik, Julian; Novomesky, Frantisek

    2014-03-01

    Spontaneous hemothorax is a well-known yet seldom-reported entity in forensic literature. While trauma-related hemothorax is frequently encountered in a medicolegal setting, non-traumatic and spontaneous hemothorax are relatively uncommon entities. The wide range of causes that can trigger fatal intrathoracic bleeding include thoracic aortic dissection, followed by vascular malformations, various oncological diseases, and connective tissue abnormalities. In rare instances, extramedullary hematopoiesis, ectopic pregnancy, congenital heart defects, amyloidosis, or parasitic diseases may constitute a source of bleeding. This etiological heterogeneity may, as a result, cause diagnostic difficulties during post-mortem elucidation of hemothorax. It should be borne in mind that hemothorax after low-energy trauma does not exclusively indicate traumatic hemorrhage, hence, the non-traumatic origin of bleeding must be taken into consideration. In this paper, we present a systematic review of the relevant literature enriched by the results of our observations to investigate the etiologies and recommendations for the post-mortem diagnosis of spontaneous hemothorax in an attempt to better delineate the possible medicolegal considerations. It is important that forensic pathologist as well as clinicians are aware of the diseases that could potentially give rise to fatal hemothorax. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Completing fishing monitoring with spaceborne Vessel Detection System (VDS) and Automatic Identification System (AIS) to assess illegal fishing in Indonesia.

    PubMed

    Longépé, Nicolas; Hajduch, Guillaume; Ardianto, Romy; Joux, Romain de; Nhunfat, Béatrice; Marzuki, Marza I; Fablet, Ronan; Hermawan, Indra; Germain, Olivier; Subki, Berny A; Farhan, Riza; Muttaqin, Ahmad Deni; Gaspar, Philippe

    2017-10-26

    The Indonesian fisheries management system is now equipped with the state-of-the-art technologies to deter and combat Illegal, Unreported and Unregulated (IUU) fishing. Since October 2014, non-cooperative fishing vessels can be detected from spaceborne Vessel Detection System (VDS) based on high resolution radar imagery, which directly benefits to coordinated patrol vessels in operation context. This study attempts to monitor the amount of illegal fishing in the Arafura Sea based on this new source of information. It is analyzed together with Vessel Monitoring System (VMS) and satellite-based Automatic Identification System (Sat-AIS) data, taking into account their own particularities. From October 2014 to March 2015, i.e. just after the establishment of a new moratorium by the Indonesian authorities, the estimated share of fishing vessels not carrying VMS, thus being illegal, ranges from 42 to 47%. One year later in January 2016, this proportion decreases and ranges from 32 to 42%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. First beam measurements on the vessel for extraction and source plasma analyses (VESPA) at the Rutherford Appleton Laboratory (RAL)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawrie, Scott R., E-mail: scott.lawrie@stfc.ac.uk; John Adams Institute for Accelerator Science, Department of Physics, University of Oxford; Faircloth, Daniel C.

    2015-04-08

    In order to facilitate the testing of advanced H{sup −} ion sources for the ISIS and Front End Test Stand (FETS) facilities at the Rutherford Appleton Laboratory (RAL), a Vessel for Extraction and Source Plasma Analyses (VESPA) has been constructed. This will perform the first detailed plasma measurements on the ISIS Penning-type H{sup −} ion source using emission spectroscopic techniques. In addition, the 30-year-old extraction optics are re-designed from the ground up in order to fully transport the beam. Using multiple beam and plasma diagnostics devices, the ultimate aim is improve H{sup −} production efficiency and subsequent transport for eithermore » long-term ISIS user operations or high power FETS requirements. The VESPA will also accommodate and test a new scaled-up Penning H{sup −} source design. This paper details the VESPA design, construction and commissioning, as well as initial beam and spectroscopy results.« less

  12. Impedance cardiography: What is the source of the signal?

    NASA Astrophysics Data System (ADS)

    Patterson, R. P.

    2010-04-01

    Impedance cardiography continues to be investigated for various applications. Instruments for its use are available commercially. Almost all of the recent presentations and articles along with commercial advertisements have assumed that aortic volume pulsation is the source of the signal. A review of the literature will reveal that there is no clear evidence for this assumption. Starting with the first paper on impedance cardiography in 1964, which assumed the lung was the source of the signal, the presentation will review many studies in the 60's, 70's and 80's, which suggest the aorta and other vessels as well as atria and again the lung as possible sources. Current studies based on high resolution thoracic models will be presented that show the aorta as contributing only approximately 1% of the total impedance measurement, making it an unlikely candidate for the major contributor to the signal. Combining the results of past studies along with recent work based on models, suggest other vessels and regions as possible sources.

  13. [Feasibility Study of Dual-source Computed Tomography High-pitch Scan Mode in Preoperative Evaluation of Aortic Stenosis Referred to Transcatheter Aortic Valve Implantation].

    PubMed

    Peng, Liqing; Yu, Jianqun; Li, Zhenlin; Li, Wanjiang; Cheng, Wei

    2016-10-01

    The purpose of this study was to explore the feasibility of dual-source computed tomography(DSCT)highpitch scan mode in the preoperative evaluation of severe aortic stenosis(AS)referred to transcatheter aortic valve implantation(TAVI).Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography.Measurement and calculation of contrast,contrast noise ratio(CNR)and noise of aorta and access vessels were performed.The intra-and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated.Evaluation of shape and plagues of aorta and access vessels was performed.The contrast,CNR and noise of aorta and access vessels were 348.2~457.9HU,12.2~30.3HU and 19.1~48.1 HU,respectively.There were good intra-and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT(mean difference:-0.73~0.79 mm,r=0.90~0.98,P<0.001;mean difference:-0.70~0.73 mm,r=0.90~0.96,P<0.001).In the 30 patients,the diameters of external iliac artery,femeral artery or subclavian artery were less than 7mm in 5cases(16.7%),marked calcification in bilateral common iliac arteries in 1case(3.3%)and marked soft plaque in left common iliac artery in 1case(3.3%).DSCT high-pitch scan mode was feasible in the preoperative evaluation of aorta and access vessels in patients with AS referred for TAVI.

  14. Metrics of Cellular and Vascular Infiltration of Human Acellular Dermal Matrix in Ventral Hernia Repairs

    PubMed Central

    Campbell, Kristin Turza; Burns, Nadja K.; Ensor, Joe; Butler, Charles E.

    2012-01-01

    Background Human acellular dermal matrix (HADM) is used for ventral hernia repair, as it resists infection and remodels via surrounding tissue. However, the tissue source and impact of basement membrane (BM) on cell and vessel infiltration have not been determined. We hypothesized that musculofascia would be the primary tissue source of cells and vessels infiltrating into HADM and the BM would inhibit infiltration. Methods Fifty-six guinea pigs underwent inlay HADM ventral hernia repair with the BM oriented toward or away from the peritoneum. At postoperative weeks 1, 2, or 4, repair sites were completely excised. Histologic and immunohistochemical analyses were performed to quantify cell and vessel density within repair-site zones, including interface (lateral, beneath musculofascia) and center (beneath subcutaneous fat) zones. Cell and vessel quantities were compared as functions of zone, BM orientation, and time. Results Cellular and vascular infiltration increased over time universally. The interface demonstrated greater mean cell density than the center (weeks 1 and 2, p=0.01, p<0.0001). Cell density was greater with the BM oriented toward the peritoneum at week 4 (p=0.02). The interface zone had greater mean vessel density than the center zone at week 4 (p<0.0001). Orienting the BM toward the peritoneum increased vessel density at week 4 (p=0.0004). Conclusion Cellular and vascular infiltration into HADM for ventral hernia repairs was greater from musculofascia than subcutaneous and the BM inhibited cellular and vascular. HADM should be placed adjacent to the best vascularizing tissue to improve fibrovascular incorporation. PMID:22456361

  15. Low Immunogenic Endothelial Cells Maintain Morphological and Functional Properties Required for Vascular Tissue Engineering.

    PubMed

    Lau, Skadi; Eicke, Dorothee; Carvalho Oliveira, Marco; Wiegmann, Bettina; Schrimpf, Claudia; Haverich, Axel; Blasczyk, Rainer; Wilhelmi, Mathias; Figueiredo, Constança; Böer, Ulrike

    2018-03-01

    The limited availability of native vessels suitable for the application as hemodialysis shunts or bypass material demands new strategies in cardiovascular surgery. Tissue-engineered vascular grafts containing autologous cells are considered ideal vessel replacements due to the low risk of rejection. However, endothelial cells (EC), which are central components of natural blood vessels, are difficult to obtain from elderly patients of poor health. Umbilical cord blood represents a promising alternative source for EC, but their allogeneic origin corresponds with the risk of rejection after allotransplantation. To reduce this risk, the human leukocyte antigen class I (HLA I) complex was stably silenced by lentiviral vector-mediated RNA interference (RNAi) in EC from peripheral blood and umbilical cord blood and vein. EC from all three sources were transduced by 93.1% ± 4.8% and effectively, HLA I-silenced by up to 67% compared to nontransduced (NT) cells or transduced with a nonspecific short hairpin RNA, respectively. Silenced EC remained capable to express characteristic endothelial surface markers such as CD31 and vascular endothelial cadherin important for constructing a tight barrier, as well as von Willebrand factor and endothelial nitric oxide synthase important for blood coagulation and vessel tone regulation. Moreover, HLA I-silenced EC were still able to align under unidirectional flow, to take up acetylated low-density lipoprotein, and to form capillary-like tube structures in three-dimensional fibrin gels similar to NT cells. In particular, addition of adipose tissue-derived mesenchymal stem cells significantly improved tube formation capability of HLA I-silenced EC toward long and widely branched vascular networks necessary for prevascularizing vascular grafts. Thus, silencing HLA I by RNAi represents a promising technique to reduce the immunogenic potential of EC from three different sources without interfering with EC-specific morphological and functional properties required for vascular tissue engineering. This extends the spectrum of available cell sources from autologous to allogeneic sources, thereby accelerating the generation of tissue-engineered vascular grafts in acute clinical cases.

  16. Traumatic brain injury rehabilitation: case management and insurance-related issues.

    PubMed

    Pressman, Helaine Tobey

    2007-02-01

    Traumatic brain injury (TBI) cases are medically complex, involving the physical, cognitive, behavioral, social, and emotional aspects of the survivor. Often catastrophic, these cases require substantial financial resources not only for the patient's survival but to achieve the optimal outcome of a functional life with return to family and work responsibilities for the long term. TBI cases involve the injured person, the family, medical professionals such as treating physicians, therapists, attorneys, the employer, community resources, and the funding source, usually an insurance company. Case management is required to facilitate achievement of an optimal result by collaborating with all parties involved, assessing priorities and options, coordinating services, and educating and communicating with all concerned.

  17. Cloud storage based mobile assessment facility for patients with post-traumatic stress disorder using integrated signal processing algorithm

    NASA Astrophysics Data System (ADS)

    Balbin, Jessie R.; Pinugu, Jasmine Nadja J.; Basco, Abigail Joy S.; Cabanada, Myla B.; Gonzales, Patrisha Melrose V.; Marasigan, Juan Carlos C.

    2017-06-01

    The research aims to build a tool in assessing patients for post-traumatic stress disorder or PTSD. The parameters used are heart rate, skin conductivity, and facial gestures. Facial gestures are recorded using OpenFace, an open-source face recognition program that uses facial action units in to track facial movements. Heart rate and skin conductivity is measured through sensors operated using Raspberry Pi. Results are stored in a database for easy and quick access. Databases to be used are uploaded to a cloud platform so that doctors have direct access to the data. This research aims to analyze these parameters and give accurate assessment of the patient.

  18. 40 CFR Table 8 to Subpart Ppp of... - Routine Reports Required by This Subpart

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....1439(e)(6) Periodic Reports Semiannually, no later than 60 days after the end of each 6-month period... refilling of each storage vessel or the inspection of each storage vessel. a There may be two versions of... after June 1, 1999. § 63.1439(e)(4) Precompliance Report a Existing affected sources: 12 months prior to...

  19. 40 CFR Table 8 to Subpart Ppp of... - Routine Reports Required by This Subpart

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1439(e)(6) Periodic Reports Semiannually, no later than 60 days after the end of each 6-month period... refilling of each storage vessel or the inspection of each storage vessel. a There may be two versions of... after June 1, 1999. § 63.1439(e)(4) Precompliance Report a Existing affected sources: 12 months prior to...

  20. 40 CFR Table 8 to Subpart Ppp of... - Routine Reports Required by This Subpart

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....1439(e)(6) Periodic Reports Semiannually, no later than 60 days after the end of each 6-month period... refilling of each storage vessel or the inspection of each storage vessel. a There may be two versions of... after June 1, 1999. § 63.1439(e)(4) Precompliance Report a Existing affected sources: 12 months prior to...

  1. 78 FR 11821 - Takes of Marine Mammals Incidental to Specified Activities; Low-Energy Marine Geophysical Survey...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-20

    ...). In most cases, the avoidance radii for delphinids appear to be small, on the order of one km or [email protected] . NMFS is not responsible for email comments sent to addresses other than the one... use one source vessel, the R/V Pelican (Pelican), or similar vessel, and a seismic airgun array to...

  2. Time-jittered marine seismic data acquisition via compressed sensing and sparsity-promoting wavefield reconstruction

    NASA Astrophysics Data System (ADS)

    Wason, H.; Herrmann, F. J.; Kumar, R.

    2016-12-01

    Current efforts towards dense shot (or receiver) sampling and full azimuthal coverage to produce high resolution images have led to the deployment of multiple source vessels (or streamers) across marine survey areas. Densely sampled marine seismic data acquisition, however, is expensive, and hence necessitates the adoption of sampling schemes that save acquisition costs and time. Compressed sensing is a sampling paradigm that aims to reconstruct a signal--that is sparse or compressible in some transform domain--from relatively fewer measurements than required by the Nyquist sampling criteria. Leveraging ideas from the field of compressed sensing, we show how marine seismic acquisition can be setup as a compressed sensing problem. A step ahead from multi-source seismic acquisition is simultaneous source acquisition--an emerging technology that is stimulating both geophysical research and commercial efforts--where multiple source arrays/vessels fire shots simultaneously resulting in better coverage in marine surveys. Following the design principles of compressed sensing, we propose a pragmatic simultaneous time-jittered time-compressed marine acquisition scheme where single or multiple source vessels sail across an ocean-bottom array firing airguns at jittered times and source locations, resulting in better spatial sampling and speedup acquisition. Our acquisition is low cost since our measurements are subsampled. Simultaneous source acquisition generates data with overlapping shot records, which need to be separated for further processing. We can significantly impact the reconstruction quality of conventional seismic data from jittered data and demonstrate successful recovery by sparsity promotion. In contrast to random (sub)sampling, acquisition via jittered (sub)sampling helps in controlling the maximum gap size, which is a practical requirement of wavefield reconstruction with localized sparsifying transforms. We illustrate our results with simulations of simultaneous time-jittered marine acquisition for 2D and 3D ocean-bottom cable survey.

  3. Two field trials for deblending of simultaneous source surveys: Why we failed and why we succeeded?

    NASA Astrophysics Data System (ADS)

    Zu, Shaohuan; Zhou, Hui; Chen, Haolin; Zheng, Hao; Chen, Yangkang

    2017-08-01

    Currently, deblending is the main strategy for dealing with the intense interference problem of simultaneous source data. Most deblending methods are based on the property that useful signal is coherent while the interference is incoherent in some domains other than common shot domain. In this paper, two simultaneous source field trials were studied in detail. In the first trial, the simultaneous source survey was not optimal, as the dithering code had strong coherency and the minimum distance between the two vessels was also small. The chosen marine shot scheduling and vessel deployment made it difficult to deblend the simultaneous source data, and result was an unexpected failure. Next, we tested different parameters (the dithering code and the minimum distance between vessels) of the simultaneous source survey using the simulated blended data and got some useful insights. Then, we carried out the second field trial with a carefully designed survey that was much different from the first trial. The deblended results in common receiver gather, common shot gather or the final stacked profile were encouraging. We obtained a complete success in the second field trial, which gave us confidence in the further test (such as a full three dimensional acquisition test or a high-resolution acquisition test with denser spatial sampling). Remembering that failures with simultaneous sourcing seldom reported, in this paper, our contribution is the discussion in detail about both our failed and successful field experiments and the lessons we have learned from them with the hope that the experience gained from this study can be very useful to other researchers in the same field.

  4. Analyses of the reflector tank, cold source, and beam tube cooling for ANS reactor. [Advanced Neutron Source (ANS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marland, S.

    1992-07-01

    This report describes my work as an intern with Martin Marietta Energy Systems, Inc., in the summer of 1991. I was assigned to the Reactor Technology Engineering Department, working on the Advanced Neutron Source (ANS). My first project was to select and analyze sealing systems for the top of the diverter/reflector tank. This involved investigating various metal seals and calculating the forces necessary to maintain an adequate seal. The force calculations led to an analysis of several bolt patterns and lockring concepts that could be used to maintain a seal on the vessel. Another project involved some pressure vessel stressmore » calculations and the calculation of the center of gravity for the cold source assembly. I also completed some sketches of possible cooling channel patterns for the inner vessel of the cold source. In addition, I worked on some thermal design analyses for the reflector tank and beam tubes, including heat transfer calculations and assisting in Patran and Pthermal analyses. To supplement the ANS work, I worked on other projects. I completed some stress/deflection analyses on several different beams. These analyses were done with the aid of CAASE, a beam-analysis software package. An additional project involved bending analysis on a carbon removal system. This study was done to find the deflection of a complex-shaped beam when loaded with a full waste can.« less

  5. 46 CFR 129.315 - Power sources for OSVs of 100 or more gross tons.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.315 Power sources for OSVs... 46 Shipping 4 2013-10-01 2013-10-01 false Power sources for OSVs of 100 or more gross tons. 129....10 of this chapter. (b) If a generator provides electrical power for any system identified as a vital...

  6. 46 CFR 129.315 - Power sources for OSVs of 100 or more gross tons.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.315 Power sources for OSVs... 46 Shipping 4 2011-10-01 2011-10-01 false Power sources for OSVs of 100 or more gross tons. 129....10 of this chapter. (b) If a generator provides electrical power for any system identified as a vital...

  7. 46 CFR 129.315 - Power sources for OSVs of 100 or more gross tons.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.315 Power sources for OSVs... 46 Shipping 4 2012-10-01 2012-10-01 false Power sources for OSVs of 100 or more gross tons. 129....10 of this chapter. (b) If a generator provides electrical power for any system identified as a vital...

  8. Molybdenum enhanced low-temperature deposition of crystalline silicon nitride

    DOEpatents

    Lowden, Richard A.

    1994-01-01

    A process for chemical vapor deposition of crystalline silicon nitride which comprises the steps of: introducing a mixture of a silicon source, a molybdenum source, a nitrogen source, and a hydrogen source into a vessel containing a suitable substrate; and thermally decomposing the mixture to deposit onto the substrate a coating comprising crystalline silicon nitride containing a dispersion of molybdenum silicide.

  9. The effect of vessel speed on the survivorship of biofouling organisms at different hull locations.

    PubMed

    Coutts, Ashley D M; Piola, Richard F; Taylor, Michael D; Hewitt, Chad L; Gardner, Jonathan P A

    2010-07-01

    This study used a specially designed MAGPLATE system to quantify the en route survivorship and post-voyage recovery of biofouling assemblages subjected to short voyages (< 12 h) across a range of vessel speeds (slow, medium, fast; in the range 4.0-21.5 knots). The effect of hull location (bow, amidships and stern) was also examined. While no significant differences were evident in en route survivorship of biofouling organisms amongst hull locations, biofouling cover and richness were markedly reduced on faster vessels relative to slower craft. Therefore, the potential inoculum size of non-indigenous marine species and richness is likely to be reduced for vessels that travel at faster speeds (> 14 knots), which is likely to also reduce the chances of successful introductions. Despite this, the magnitude of introductions from biofouling on fast vessels can be considered minor, especially for species richness where 90% of source-port species were recorded at destinations.

  10. Mapping underwater sound noise and assessing its sources by using a self-organizing maps method.

    PubMed

    Rako, Nikolina; Vilibić, Ivica; Mihanović, Hrvoje

    2013-03-01

    This study aims to provide an objective mapping of the underwater noise and its sources over an Adriatic coastal marine habitat by applying the self-organizing maps (SOM) method. Systematic sampling of sea ambient noise (SAN) was carried out at ten predefined acoustic stations between 2007 and 2009. Analyses of noise levels were performed for 1/3 octave band standard centered frequencies in terms of instantaneous sound pressure levels averaged over 300 s to calculate the equivalent continuous sound pressure levels. Data on vessels' presence, type, and distance from the monitoring stations were also collected at each acoustic station during the acoustic sampling. Altogether 69 noise surveys were introduced to the SOM predefined 2 × 2 array. The overall results of the analysis distinguished two dominant underwater soundscapes, associating them mainly to the seasonal changes in the nautical tourism and fishing activities within the study area and to the wind and wave action. The analysis identified recreational vessels as the dominant anthropogenic source of underwater noise, particularly during the tourist season. The method demonstrated to be an efficient tool in predicting the SAN levels based on the vessel distribution, indicating also the possibility of its wider implication for marine conservation.

  11. 40 CFR 63.5490 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to each new, reconstructed, or existing affected source for the Miscellaneous Viscose Processes and Cellulose Ethers Production source categories. (b) The affected source for the Miscellaneous Viscose... paragraph (c)(3) or (4) of this section. (1) The input to the storage vessel from your viscose process or...

  12. 40 CFR 63.5490 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to each new, reconstructed, or existing affected source for the Miscellaneous Viscose Processes and Cellulose Ethers Production source categories. (b) The affected source for the Miscellaneous Viscose... paragraph (c)(3) or (4) of this section. (1) The input to the storage vessel from your viscose process or...

  13. Benthic marine litter in four Gulfs in Greece, Eastern Mediterranean; abundance, composition and source identification

    NASA Astrophysics Data System (ADS)

    Koutsodendris, Andreas; Papatheodorou, George; Kougiourouki, Ourania; Georgiadis, Michalis

    2008-04-01

    The types, abundance, distribution and sources of benthic marine litter found in four Greek Gulfs (Patras, Corinth, Echinades and Lakonikos) were studied using bottom trawl nets. Mean distribution and weight densities range between 72-437 Item/km 2 and 6.7-47.4 kg/km 2. Litter items were sorted into material and usage categories. Plastic litter (56%) is the most dominant material category followed by metal (17%) and glass (11%). Beverage packaging (32%) is the dominant usage category followed by general packaging (28%) and food packaging (21%). Based on the typological results three dominant litter sources were identified; land-based, vessel-based and fishery-based. Application of factor analysis (R- and Q-mode) conducted on both material and usage litter datasets confirmed the existence of the three dominant litter sources. Q-mode analysis further resulted in the quantification of the litter sources; land-based ones provided the majority (69%) of the total litter items followed by vessel-based (26%) and fishery-based (5%) sources. Diverse environmental parameters influence significantly these amounts among the four Gulfs.

  14. Calibration of Seismic Sources during a Test Cruise with the new RV SONNE

    NASA Astrophysics Data System (ADS)

    Engels, M.; Schnabel, M.; Damm, V.

    2015-12-01

    During autumn 2014, several test cruises of the brand new German research vessel SONNE were carried out before the first official scientific cruise started in December. In September 2014, BGR conducted a seismic test cruise in the British North Sea. RV SONNE is a multipurpose research vessel and was also designed for the mobile BGR 3D seismic equipment, which was tested successfully during the cruise. We spend two days for calibration of the following seismic sources of BGR: G-gun array (50 l @ 150 bar) G-gun array (50 l @ 207 bar) single GI-gun (3.4 l @ 150 bar) For this experiment two hydrophones (TC4042 from Reson Teledyne) sampling up to 48 kHz were fixed below a drifting buoy at 20 m and 60 m water depth - the sea bottom was at 80 m depth. The vessel with the seismic sources sailed several up to 7 km long profiles around the buoy in order to cover many different azimuths and distances. We aimed to measure sound pressure level (SPL) and sound exposure level (SEL) under the conditions of the shallow North Sea. Total reflections and refracted waves dominate the recorded wave field, enhance the noise level and partly screen the direct wave in contrast to 'true' deep water calibration based solely on the direct wave. Presented are SPL and RMS power results in time domain, the decay with distance along profiles, and the somehow complicated 2D sound radiation pattern modulated by topography. The shading effect of the vessel's hull is significant. In frequency domain we consider 1/3 octave levels and estimate the amount of energy in frequency ranges not used for reflection seismic processing. Results are presented in comparison of the three different sources listed above. We compare the measured SPL decay with distance during this experiment with deep water modeling of seismic sources (Gundalf software) and with published results from calibrations with other marine seismic sources under different conditions: E.g. Breitzke et al. (2008, 2010) with RV Polarstern, Tolstoy et al. (2004) with RV Ewing and Tolstoy et al. (2009) with RV Langseth, and Crone et al. (2014) with RV Langseth.

  15. Paternal mental health following perceived traumatic childbirth.

    PubMed

    Inglis, Christian; Sharman, Rachael; Reed, Rachel

    2016-10-01

    the objective behind the current study was to explore the experiences and perceptions of fathers after childbirth trauma, an area of minimal research. This is part two of a two-part series conducted in 2014 researching the mental health of fathers after experiencing a perceived traumatic childbirth. qualitative methodology using semi-structured interviews and reporting of qualitative questions administered in part one's online survey (Inglis, 2014). interviews conducted face-to-face at an Australian University or on Skype. sixty-nine responded to the online qualitative questions and of these seven were interviewed. thematic analysis of verbal and written qualitative responses. thematic analysis of qualitative survey data and interviews found a global theme 'standing on the sideline' which encompassed two major themes of witnessing trauma: unknown territory, and the aftermath: dealing with it, and respective subthemes. according to the perceptions and experiences of the fathers, there was a significant lack of communication between birthing teams and fathers, and fathers experienced a sense of marginalisation before, during, and after the traumatic childbirth. The findings of this study suggest that these factors contributed to the perception of trauma in the current sample. Whilst many fathers reported the negative impact of the traumatic birth on themselves and their relationships, some reported post-traumatic growth from the experience and others identified friends and family as a valuable source of support. improved communication between midwifery staff and fathers before, during and after childbirth may reduce the rates of paternal postpartum mental health difficulties and experiences of trauma. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Knowledge of elementary school teachers in Tel-Aviv, Israel, regarding emergency care of dental injuries.

    PubMed

    Fux-Noy, Avia; Sarnat, Haim; Amir, Erica

    2011-08-01

    Immediate management of traumatized teeth is often critical to the prognosis of the teeth. Most of the traumatic dental injuries occur at home, followed by school. There is a high probability that first aid would be given by lay people such as parents, teachers, or coaches. Knowledge of those people regarding emergency management of dental trauma is crucial for better prognosis. To investigate: (i) the knowledge of elementary school teachers regarding traumatic dental injuries to permanent teeth and emergency treatment, (ii) their source of information, and (iii) the demand for more education in dental trauma. A three-part questionnaire comprised of questions regarding demographic data, attitude, and knowledge about dental injuries was distributed to teachers in 12 elementary schools in the Tel-Aviv area, Israel. The average knowledge score was 4.59 (in a scale of 0-10). Three individual predictors significantly improved the respondents' knowledge: being in the 35-49-year age group (P-value = 0.042), those who had children themselves (P-value = 0.002) and those who had previous experience with trauma (P-value = 0.049). There was no correlation between the demand for further education in dental trauma and knowledge score. The knowledge regarding management of traumatic dental injuries in a group of teachers in the Tel-Aviv area is inadequate. Educational programs as well as addition to the curriculum are necessary to improve their emergency management of traumatic dental injuries and provide better protection to the students. © 2011 John Wiley & Sons A/S.

  17. Imaging of the Posterior Skull Base.

    PubMed

    Job, Joici; Branstetter, Barton F

    2017-01-01

    The posterior skull base can be involved by a variety of pathologic processes. They can be broadly classified as: traumatic, neoplastic, vascular, and inflammatory. Pathology in the posterior skull base usually involves the lower cranial nerves, either as a source of pathology or a secondary source of symptoms. This review will categorize pathology arising in the posterior skull base and describe how it affects the skull base itself and surrounding structures. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Source and Portal of Entry of Bacteria Found in Bruised Poultry Tissue1

    PubMed Central

    Hamdy, M. K.; Barton, N. D.; Brown, W. E.

    1964-01-01

    Bacteriological studies revealed that normal tissue, air sacs, feathers, skin of birds, poultry feed, gut, and chicken droppings were sources of the predominant organisms, including staphylococci, found in bruised poultry tissue. Further investigation of normal tissue revealed that after the intramuscular injection of Staphylococcus aureus, marker strain (MS), the organism was eliminated from these tissues within 7 days. However, when these tissues were traumatized 3 days after injection, the number of the test organism increased, and the organism was present on the 7th day after inoculation. Poultry feed and fecal material contained a large number of staphylococci identical to those isolated from bruised tissue (McCarthy, Brown, and Hamdy, 1963), thereby implicating the gut as a possible portal of entry. When a pathogenic marker strain of S. aureus was established in the intestinal tract of chickens by administering an active culture of this organism either in their drinking water or by gavage, it was recovered from the traumatized tissue. The incidence of positive culture of S. aureus MS in these tissues correlated with age of bruise, reaching 22 to 33% immediately after contusion and at the early stages of healing (1 to 3 days post bruise) and decreasing thereafter from 11 to 0% on the 4th through 6th days after bruise infliction. The air sac was also found to be a site by which bacteria may enter the traumatized tissues, but to a limited extent. PMID:14239576

  19. Family as a Total Package: Restoring and Enhancing Psychological Health for Citizen Soldiers and Families

    DTIC Science & Technology

    2014-03-14

    Kurt Goldstein, 1878-1965 Traumatic Brain Injury (TBI)*  Before Vietnam • “Shell shock” initially meant nervous system damage from concussive blast...TBIs ( football , vehicle accidents). • Information is readily available for service members, veterans and civilians. *Various sources; MacDonald et

  20. Gaia: "Thinking Like a Planet" as Transformative Learning

    ERIC Educational Resources Information Center

    Haigh, Martin

    2014-01-01

    Transformative learning may involve gentle perspective widening or something more traumatic. This paper explores the impact of a transformative pedagogy in a course that challenges learners to "think like a planet". Among six sources of intellectual anxiety, learners worry about: why Gaia Theory is neglected by their other courses; the…

  1. Absence of the genicular arterial anastomosis as generally depicted in textbooks.

    PubMed

    Sabalbal, M; Johnson, M; McAlister, V

    2013-09-01

    Textbook representations of the genicular arterial anastomosis show a large direct communication between the descending branch of the lateral circumflex femoral artery (DBLCFA) and a genicular branch of the popliteal artery but this is not compatible with clinical experience. The aim of this study was to determine whether the arterial anastomosis at the knee is sufficient, in the event of traumatic disruption of the superficial femoral artery, to infuse protective agents or to place a stent to restore flow to the lower leg. Dissection of ten cadaveric lower limbs was performed to photograph the arterial anatomy from the inguinal ligament to the tibial tubercle. Anastomosis with branches of the popliteal artery was classified as: 'direct communication', 'approaching communication' or 'no evident communication'. A constant descending artery in the lateral thigh (LDAT) was found to have five types of origin: Type 1 (2/10 limbs) involved the lateral circumflex femoral branch of the femoral artery, Type 2 (3/10 limbs) the lateral circumflex femoral branch of the profunda femoris artery, Type 3 (1/10 limbs) the femoral artery, Type 4 (3/10 limbs) the superficial femoral artery and Type 5 (2/10 limbs) the profunda femoris artery. In one limb, there were two descending arteries (Types 4 and 5). Collateral circulation at the knee was also variable: direct communicating vessels (3/10 limbs); approaching vessels with possible communication via capillaries (5/10 limbs); no evident communication (2/10 limbs). Communicating vessels, if present, are too small to provide immediate collateral circulation. Modern representations of the genicular arterial anastomosis are inaccurate, derived commonly from an idealised image that first appeared Gray's Anatomy in 1910. The afferent vessel is not the DBLCFA. The majority of subjects have the potential to recruit collateral circulation via the LDAT following gradual obstruction to normal arterial flow, which may be important if the LDAT is removed for bypass or flap surgery. A direct communication is rarely present and is never as robust as generally depicted in textbooks.

  2. Reactive Swarm Formation Control Using Realistic Surface Vessel Dynamics and Environmental Effects

    DTIC Science & Technology

    2012-05-10

    hour per response, including the time for reviewing instructions. searching existing data sources. gathering and maintaining the data needed, and...1997, 2001, 2003, % % %(#) Department fo Automation % Danish Technical University, DTU . % DK 2800 Kgs. Lyngby, Denmark...tristan.perez@ntnu.no % Date: 2005-05-04 % Comments: %Adapted from the files reference (*) to match the data of the vessel %design of ADI-Limited

  3. Lung vessel segmentation in CT images using graph-cuts

    NASA Astrophysics Data System (ADS)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  4. Molybdenum enhanced low-temperature deposition of crystalline silicon nitride

    DOEpatents

    Lowden, R.A.

    1994-04-05

    A process for chemical vapor deposition of crystalline silicon nitride is described which comprises the steps of: introducing a mixture of a silicon source, a molybdenum source, a nitrogen source, and a hydrogen source into a vessel containing a suitable substrate; and thermally decomposing the mixture to deposit onto the substrate a coating comprising crystalline silicon nitride containing a dispersion of molybdenum silicide. 5 figures.

  5. Defining traumatic brain injury in children and youth using international classification of diseases version 10 codes: a systematic review protocol.

    PubMed

    Chan, Vincy; Thurairajah, Pravheen; Colantonio, Angela

    2013-11-13

    Although healthcare administrative data are commonly used for traumatic brain injury research, there is currently no consensus or consistency on using the International Classification of Diseases version 10 codes to define traumatic brain injury among children and youth. This protocol is for a systematic review of the literature to explore the range of International Classification of Diseases version 10 codes that are used to define traumatic brain injury in this population. The databases MEDLINE, MEDLINE In-Process, Embase, PsychINFO, CINAHL, SPORTDiscus, and Cochrane Database of Systematic Reviews will be systematically searched. Grey literature will be searched using Grey Matters and Google. Reference lists of included articles will also be searched. Articles will be screened using predefined inclusion and exclusion criteria and all full-text articles that meet the predefined inclusion criteria will be included for analysis. The study selection process and reasons for exclusion at the full-text level will be presented using a PRISMA study flow diagram. Information on the data source of included studies, year and location of study, age of study population, range of incidence, and study purpose will be abstracted into a separate table and synthesized for analysis. All International Classification of Diseases version 10 codes will be listed in tables and the codes that are used to define concussion, acquired traumatic brain injury, head injury, or head trauma will be identified. The identification of the optimal International Classification of Diseases version 10 codes to define this population in administrative data is crucial, as it has implications for policy, resource allocation, planning of healthcare services, and prevention strategies. It also allows for comparisons across countries and studies. This protocol is for a review that identifies the range and most common diagnoses used to conduct surveillance for traumatic brain injury in children and youth. This is an important first step in reaching an appropriate definition using International Classification of Diseases version 10 codes and can inform future work on reaching consensus on the codes to define traumatic brain injury for this vulnerable population.

  6. Non-contact method of search and analysis of pulsating vessels

    NASA Astrophysics Data System (ADS)

    Avtomonov, Yuri N.; Tsoy, Maria O.; Postnov, Dmitry E.

    2018-04-01

    Despite the variety of existing methods of recording the human pulse and a solid history of their development, there is still considerable interest in this topic. The development of new non-contact methods, based on advanced image processing, caused a new wave of interest in this issue. We present a simple but quite effective method for analyzing the mechanical pulsations of blood vessels lying close to the surface of the skin. Our technique is a modification of imaging (or remote) photoplethysmography (i-PPG). We supplemented this method with the addition of a laser light source, which made it possible to use other methods of searching for the proposed pulsation zone. During the testing of the method, several series of experiments were carried out with both artificial oscillating objects as well as with the target signal source (human wrist). The obtained results show that our method allows correct interpretation of complex data. To summarize, we proposed and tested an alternative method for the search and analysis of pulsating vessels.

  7. Integrated reformer and shift reactor

    DOEpatents

    Bentley, Jeffrey M.; Clawson, Lawrence G.; Mitchell, William L.; Dorson, Matthew H.

    2006-06-27

    A hydrocarbon fuel reformer for producing diatomic hydrogen gas is disclosed. The reformer includes a first reaction vessel, a shift reactor vessel annularly disposed about the first reaction vessel, including a first shift reactor zone, and a first helical tube disposed within the first shift reactor zone having an inlet end communicating with a water supply source. The water supply source is preferably adapted to supply liquid-phase water to the first helical tube at flow conditions sufficient to ensure discharge of liquid-phase and steam-phase water from an outlet end of the first helical tube. The reformer may further include a first catalyst bed disposed in the first shift reactor zone, having a low-temperature shift catalyst in contact with the first helical tube. The catalyst bed includes a plurality of coil sections disposed in coaxial relation to other coil sections and to the central longitudinal axis of the reformer, each coil section extending between the first and second ends, and each coil section being in direct fluid communication with at least one other coil section.

  8. Vortex-induced vibration (VIV) effects of a drilling riser due to vessel motion

    NASA Astrophysics Data System (ADS)

    Joseph, R. S.; Wang, J.; Ong, M. C.; Jakobsen, J. B.

    2017-12-01

    A marine riser undergoes oscillatory motion in water due to the vessel motions, known as global dynamic response. This to-and-fro motion of the riser will generate an equivalent flow that can cause Vortex-Induced Vibrations (VIVs), even in the absence of the ocean current. In the present work, full-scale measurement data of a drilling riser operating in the Gulf of Mexico are analysed. The VIV occurrences for the riser are identified from the data and the possible excitation sources are discussed. The oscillatory flow due to vessel motion is compared with the ocean current and its possibility to excite VIV is analysed. The full-scale data analysis provides an insight into the vessel motion-induced VIV of marine risers in the actual field environment.

  9. Metrics of cellular and vascular infiltration of human acellular dermal matrix in ventral hernia repairs.

    PubMed

    Campbell, Kristin Turza; Burns, Nadja K; Ensor, Joe; Butler, Charles E

    2012-04-01

    Human acellular dermal matrix is used for ventral hernia repair, as it resists infection and remodels by means of surrounding tissue. However, the tissue source and impact of basement membrane on cell and vessel infiltration have not been determined. The authors hypothesized that musculofascia would be the primary tissue source of cells and vessels infiltrating into human acellular dermal matrix and that the basement membrane would inhibit infiltration. Fifty-six guinea pigs underwent inlay human acellular dermal matrix ventral hernia repair with the basement membrane oriented toward or away from the peritoneum. At postoperative weeks 1, 2, or 4, repair sites were completely excised. Histologic and immunohistochemical analyses were performed to quantify cell and vessel density within repair-site zones, including interface (lateral, beneath musculofascia) and center (beneath subcutaneous fat) zones. Cell and vessel quantities were compared as functions of zone, basement membrane orientation, and time. Cellular and vascular infiltration increased over time universally. The interface demonstrated greater mean cell density than the center (weeks 1 and 2, p = 0.01 and p < 0.0001, respectively). Cell density was greater with the basement membrane oriented toward the peritoneum at week 4 (p = 0.02). The interface zone had greater mean vessel density than the center zone at week 4 (p < 0.0001). Orienting the basement membrane toward the peritoneum increased vessel density at week 4 (p = 0.0004). Cellular and vascular infiltration into human acellular dermal matrix for ventral hernia repairs was greater from musculofascia than from subcutaneous fat, and the basement membrane inhibited cellular and vascular infiltration. Human acellular dermal matrix should be placed adjacent to the best vascularizing tissue to improve fibrovascular incorporation.

  10. 46 CFR 129.315 - Power sources for OSVs of 100 or more gross tons.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.315 Power sources for OSVs... one set must be independent of the main propulsion plant. A generator not independent of the main propulsion plant must comply with § 111.10-4(d) of this chapter. With any one generating set stopped, the...

  11. 40 CFR 63.11602 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...

  12. 40 CFR 63.11602 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...

  13. 40 CFR 63.11602 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...

  14. 40 CFR 63.11602 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...

  15. 40 CFR 63.11602 - What are the performance test and compliance requirements for new and existing sources?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... compliance requirements for new and existing sources? 63.11602 Section 63.11602 Protection of Environment... Requirements § 63.11602 What are the performance test and compliance requirements for new and existing sources... compounds of cadmium, chromium, lead, or nickel to a process vessel or to the grinding and milling equipment...

  16. Characterization of an optimized light source and comparison to pulsed dye laser for superficial and deep vessel clearance.

    PubMed

    Weiss, Robert A; Ross, E Victor; Tanghetti, Emil A; Vasily, David B; Childs, James J; Smirnov, Mikhail Z; Altshuler, Gregory B

    2011-02-01

    An arc lamp-based device providing optimized spectrum and pulse shape was characterized and compared with two pulsed dye laser (PDL) systems using a vascular phantom. Safety and effectiveness for facial telangiectasia are presented in clinical case studies. An optimized pulsed light source's (OPL) spectral and power output were characterized and compared with two 595 nm PDL devices. Purpuric threshold fluences were determined for the OPL and PDLs on Fitzpatrick type II normal skin. A vascular phantom comprising blood-filled quartz capillaries beneath porcine skin was treated by the devices at their respective purpuric threshold fluences for 3 ms pulse widths, while vessel temperatures were monitored with an infrared (IR) camera. Patients with Fitzpatrick skin types II-III received a split-face treatment with the OPL and a 595 nm PDL. The OPL provided a dual-band output spectrum from 500 to 670 nm and 850-1,200 nm, pulse widths from 3 to 100 ms, and fluences to 80 J/cm(2). The smooth output power measured during all pulse widths provides unambiguous vessel size selectivity. Percent energy in the near infra-red increased with decreasing output power from 45% to 60% and contributed 15-26% to heating of deep vessels, respectively. At purpuric threshold fluences the ratio of OPL to PDL vessel temperature rise was 1.7-2.8. OPL treatments of facial telangiectasia were well-tolerated by patients demonstrating significant improvements comparable to PDL with no downtime. Intense pulsed light (IPL) and PDL output pulse and spectral profiles are important for selective treatment of vessels in vascular lesions. The OPL's margin between purpuric threshold fluence and treatment fluence for deeper, larger vessels was greater than the corresponding margin with PDLs. The results warrant further comparison studies with IPLs and other PDLs. Copyright © 2011 Wiley-Liss, Inc.

  17. Reproducibility and variability of quantitative magnetic resonance imaging markers in cerebral small vessel disease

    PubMed Central

    De Guio, François; Jouvent, Eric; Biessels, Geert Jan; Black, Sandra E; Brayne, Carol; Chen, Christopher; Cordonnier, Charlotte; De Leeuw, Frank-Eric; Dichgans, Martin; Doubal, Fergus; Duering, Marco; Dufouil, Carole; Duzel, Emrah; Fazekas, Franz; Hachinski, Vladimir; Ikram, M Arfan; Linn, Jennifer; Matthews, Paul M; Mazoyer, Bernard; Mok, Vincent; Norrving, Bo; O’Brien, John T; Pantoni, Leonardo; Ropele, Stefan; Sachdev, Perminder; Schmidt, Reinhold; Seshadri, Sudha; Smith, Eric E; Sposato, Luciano A; Stephan, Blossom; Swartz, Richard H; Tzourio, Christophe; van Buchem, Mark; van der Lugt, Aad; van Oostenbrugge, Robert; Vernooij, Meike W; Viswanathan, Anand; Werring, David; Wollenweber, Frank; Wardlaw, Joanna M

    2016-01-01

    Brain imaging is essential for the diagnosis and characterization of cerebral small vessel disease. Several magnetic resonance imaging markers have therefore emerged, providing new information on the diagnosis, progression, and mechanisms of small vessel disease. Yet, the reproducibility of these small vessel disease markers has received little attention despite being widely used in cross-sectional and longitudinal studies. This review focuses on the main small vessel disease-related markers on magnetic resonance imaging including: white matter hyperintensities, lacunes, dilated perivascular spaces, microbleeds, and brain volume. The aim is to summarize, for each marker, what is currently known about: (1) its reproducibility in studies with a scan–rescan procedure either in single or multicenter settings; (2) the acquisition-related sources of variability; and, (3) the techniques used to minimize this variability. Based on the results, we discuss technical and other challenges that need to be overcome in order for these markers to be reliably used as outcome measures in future clinical trials. We also highlight the key points that need to be considered when designing multicenter magnetic resonance imaging studies of small vessel disease. PMID:27170700

  18. Socio-demographic patterns of posttraumatic stress disorder in Medellin, Colombia and the context of lifetime trauma exposure

    PubMed Central

    Gaviria, Silvia Lucia; Espinola, Maria; Restrepo, Diana; Lotero, Juliana; Berbesi, Dedsy Y.; Sierra, Gloria Maria; Chaskel, Roberto; Espinel, Zelde; Shultz, James M.

    2016-01-01

    ABSTRACT Colombia, South America is currently transitioning to post-conflict status following 6 decades of armed conflict. The population has experienced extensive exposures to potentially traumatic events throughout the lifespan. Sources of trauma exposure include the prolonged armed insurgency, narco-trafficking violence, urban gang violence, violent actions of criminal bands, intra-familial violence, gender-based violence, and sex trafficking. Exposure to potentially traumatic events is related to a variety of psychiatric outcomes, in particular, posttraumatic stress disorder. Given this context of lifetime trauma exposure, socio-demographic patterns of posttraumatic stress disorder were explored in a sample of residents of Medellin, Colombia, the nation's second largest city and a nexus for multiple types of trauma exposure. PMID:28265488

  19. A Brain-Machine-Brain Interface for Rewiring of Cortical Circuitry after Traumatic Brain Injury

    DTIC Science & Technology

    2011-09-01

    cerebral cortex of a rat’s brain. The flow chart for spike discrimination algorithm is also shown. Negative threshold level (not shown in bottom left...portion of the transistor drain current can flow into its bulk due to impact ionization effect [40], greatly degrading the output impedance of the...current source. This can be solved by connecting the bulk and source of together, as also seen in Fig. 4, allowing its drain-bulk current to also flow

  20. Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems

    PubMed Central

    Esenaliev, Rinat O.

    2017-01-01

    Abstract. Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels. PMID:28444150

  1. Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems

    NASA Astrophysics Data System (ADS)

    Esenaliev, Rinat O.

    2017-09-01

    Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels.

  2. Building blocks toward contemporary trauma theory: Ferenczi 's paradigm shift.

    PubMed

    Mészáros, Judit

    2010-12-01

    In laying down the building blocks of contemporary trauma theory, Ferenczi asserted that trauma is founded on real events and that it occurs in the interpersonal and intersubjective dynamics of object relations. He stressed the significance of the presence or lack of a trusted person in the post-traumatic situation. After the trauma, the loneliness and later the isolation of the victim represent a serious pathogenic source. In the traumatic situation, the victim and the persecutor/aggressor operate differing ego defense mechanisms. Ferenczi was the first to describe the ego defense mechanism of identification with the aggressor. Ferenczi pointed out the characteristic features of the role of analyst/therapist with which (s)he may assist the patient in working through the trauma, among them being the development of a therapeutic atmosphere based on trust, so that the traumatic experiences can be relived, without which effective therapeutic change cannot be achieved. For the analyst, countertransference, as part of authentic communication, is incorporated into the therapeutic process. These are the key building blocks that are laid down by Ferenczi in his writings and appear in later works on trauma theory.

  3. Creating a “Pro-survival Phenotype” Through Histone Deacetylase Inhibition: Past, Present, and Future

    PubMed Central

    Halaweish, Ihab; Nikolian, Vahagn; Georgoff, Patrick; Li, Yongqing; Alam, Hasan B

    2014-01-01

    Traumatic injuries and their sequela represent a major source of mortality in the United States and globally. Initial treatment for shock, traumatic brain injury, and polytrauma is limited to resuscitation fluids to replace lost volume. To date, there are no treatments with inherent pro-survival properties. Our lab has investigated the use of histone deacetylase inhibitors (HDACIs) as pharmacological agents to improve survival. This class of drugs acts through posttranslational protein modifications and is a direct regulator of chromatin structure and function, as well as the function of numerous cytoplasmic proteins. In models of hemorrhagic shock and polytrauma, administration of HDACIs offers a significant survival advantage, even in the absence of fluid resuscitation. Positive results have also been shown in two-hit models of hemorrhage and sepsis and in hemorrhagic shock combined with traumatic brain injury. Accumulating data generated by our group and others continue to support the use of HDACIs for creation of a pro-survival phenotype. With further research and clinical trials, HDACIs have the potential to be an integral tool in treatment of trauma, especially in the pre-hospital phase. PMID:25565645

  4. Collective trauma transmission and traumatic reactions among descendants of Armenian refugees.

    PubMed

    Karenian, Hatsantour; Livaditis, Miltos; Karenian, Sirpouhi; Zafiriadis, Kyriakos; Bochtsou, Valentini; Xenitidis, Kiriakos

    2011-07-01

    It has been suggested, mainly by case reports, that the collective trauma generated by mass calamities may be transmitted to, and have long-lasting effects on, new generations. To investigate the psychological impact on contemporary Armenians of traumatic events suffered by Armenians during the period 1914-1918. A descriptive, cross-sectional study investigating demographic and cultural characteristics of a population of 689 people of Armenian origin, residents of Greece and Cyprus. Subjects were recruited during a range of Armenian cultural, athletic or charitable events. The participants completed a version of the Post-Traumatic Stress Disorder (PTSD) (Self-Rating) Scale and a questionnaire including ad hoc questions regarding their relationship to the Armenian community, their attitudes and their source of information about the 1914-1918 events. Over a third (35.7%) of participants presented at least sub-clinical forms of such reactions during long periods of their lives. Women, older people, participants with a close relative lost during the events and those with strong connections to the Armenian community were more vulnerable. The results are indicative of a long-lasting (though gradually fading) cross-generational traumatizing effect of the discussed events. Clinicians having to deal with patients belonging to cultural or ethnic groups that suffered persecutions in the past should take into account the probable effects caused by a trauma-transmission mechanism.

  5. Broadband calibration of the R/V Marcus G. Langseth four-string seismic sources

    NASA Astrophysics Data System (ADS)

    Tolstoy, M.; Diebold, J.; Doermann, L.; Nooner, S.; Webb, S. C.; Bohnenstiehl, D. R.; Crone, T. J.; Holmes, R. C.

    2009-08-01

    The R/V Marcus G. Langseth is the first 3-D seismic vessel operated by the U.S. academic community. With up to a four-string, 36-element source and four 6-km-long solid state hydrophone arrays, this vessel promises significant new insights into Earth science processes. The potential impact of anthropogenic sound sources on marine life is an important topic to the marine seismic community. To ensure that operations fully comply with existing and future marine mammal permitting requirements, a calibration experiment was conducted in the Gulf of Mexico in 2007-2008. Results are presented from deep (˜1.6 km) and shallow (˜50 m) water sites, obtained using the full 36-element (6600 cubic inches) seismic source. This array configuration will require the largest safety radii, and the deep and shallow sites provide two contrasting operational environments. Results show that safety radii and the offset between root-mean-square and sound exposure level measurements were highly dependent on water depth.

  6. Progesterone-mediated angiogenic activity of endothelial progenitor cell and angiogenesis in traumatic brain injury rats were antagonized by progesterone receptor antagonist.

    PubMed

    Yu, Peng; Li, Shengjie; Zhang, Zhifei; Wen, Xiaolong; Quan, Wei; Tian, Qilong; Gao, Chuang; Su, Wanqiang; Zhang, Jianning; Jiang, Rongcai

    2017-10-01

    Progesterone (P4) has the potential therapeutic effects for traumatic brain injury (TBI) whose recovery depended on the enhanced angiogenesis. Endothelial progenitor cell (EPC) plays an essential role in vascular biology. We previously demonstrated that P4 administration improved circulating EPC level and neurological recovery of rat with TBI. Here, we hypothesized that P4 augmented angiogenic potential of EPC and the angiogenesis-related neurorestoration after TBI through classical progesterone receptor (PR). EPC derived from rats were stimulated with graded concentrations (0, 10 -10 , 10 -9 , 5 × 10 -9 , 10 -8 , 10 -7  mol/L) of P4 or 10 -6  mol/L ulipristal acetate (UPA, a PR antagonist). Male rats were subjected to cortical impact injury and treated with (i) DMSO (dimethyl sulfoxide), (ii) P4 and (iii) P4 and UPA. It showed that P4 improved the angiogenic potential of EPC, including tube formation, adhesion, migration and vascular endothelial growth factor secretion, in a dose-dependent fashion with the maximal effect achieved at 10 -9  mol/L P4. High concentration (10 -7  mol/L) of P4 impaired the angiogenic potential of EPC. Notably, 10 -6  mol/L UPA antagonized the stimulatory effects of 10 -9  mol/L P4. After administrating P4, a significant improvement of neurological function and the restoration of the leaked blood-brain barrier were observed as well as a reduction of the brain water content. Both vessel density and expression of occludin of vessels were increased. When UPA was administered with P4, the neural restoration and angiogenesis were all reversed. Western blot showed that 10 -9  mol/L P4 increased the content of PRA and PRB of EPC, while 10 -7  mol/L P4 reduced the content of both PR isoforms, but there was no change found in the TBI rats. It may suggest that P4-mediated angiogenic activity of EPC and angiogenesis in TBI rats were antagonized by PR antagonist. © 2017 John Wiley & Sons Ltd.

  7. 46 CFR 120.312 - Power sources on vessels of more than 19.8 meters (65 feet) in length carrying more than 600...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... feet) in length carrying more than 600 passengers or with overnight accommodations for more than 49... of more than 19.8 meters (65 feet) in length carrying more than 600 passengers or with overnight accommodations for more than 49 passengers. A vessel of more than 19.8 meters (65 feet) in length carrying more...

  8. 40 CFR Table 3 to Subpart Ppp of... - Group 1 Storage Vessels at Existing and New Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 11 2011-07-01 2011-07-01 false Group 1 Storage Vessels at Existing... Polyether Polyols Production Pt. 63, Subpt. PPP, Table 3 Table 3 to Subpart PPP of Part 63—Group 1 Storage...) 75 ≤ capacity 1 capacity ≥ 151 ≥ 5.2 a Maximum true vapor pressure of total organic HAP at...

  9. Sodium storage and injection system

    NASA Technical Reports Server (NTRS)

    Keeton, A. R. (Inventor)

    1979-01-01

    A sodium storage and injection system for delivering atomized liquid sodium to a chemical reactor employed in the production of solar grade silicon is disclosed. The system is adapted to accommodate start-up, shut-down, normal and emergency operations, and is characterized by (1) a jacketed injection nozzle adapted to atomize liquefied sodium and (2) a supply circuit connected to the nozzle for delivering the liquefied sodium. The supply circuit is comprised of a plurality of replaceable sodium containment vessels, a pump interposed between the vessels and the nozzle, and a pressurizing circuit including a source of inert gas connected with the vessels for maintaining the sodium under pressure.

  10. Radiated noise from commercial ships in the Gulf of Maine: implications for whale/vessel collisions.

    PubMed

    Allen, J Kaitlyn; Peterson, Michael L; Sharrard, George V; Wright, Dana L; Todd, Sean K

    2012-09-01

    To understand mysticete acoustic-based detection of ships, radiated noise from high-speed craft, cruise ships, catamarans and fishing vessels was recorded June-September 2009. Calibrated acoustic data (<2500 Hz) from a vertical hydrophone array was combined with ship passage information. A cruise ship had the highest broadband source level, while a fishing vessel had the lowest. Ship noise radiated asymmetrically and varied with depth. Bow null-effect acoustic shadow zones were observed for all ship classes and were correlated with ship-length-to-draft-ratios. These shadow zones may reduce ship detection by near-surface mysticetes.

  11. Speaking up: Killer whales (Orcinus orca) increase their call amplitude in response to vessel noise.

    PubMed

    Holt, Marla M; Noren, Dawn P; Veirs, Val; Emmons, Candice K; Veirs, Scott

    2009-01-01

    This study investigated the effects of anthropogenic sound exposure on the vocal behavior of free-ranging killer whales. Endangered Southern Resident killer whales inhabit areas including the urban coastal waters of Puget Sound near Seattle, WA, where anthropogenic sounds are ubiquitous, particularly those from motorized vessels. A calibrated recording system was used to measure killer whale call source levels and background noise levels (1-40 kHz). Results show that whales increased their call amplitude by 1 dB for every 1 dB increase in background noise levels. Furthermore, nearby vessel counts were positively correlated with these observed background noise levels.

  12. Memory for performed and observed activities following traumatic brain injury

    PubMed Central

    Wright, Matthew J.; Wong, Andrew L.; Obermeit, Lisa C.; Woo, Ellen; Schmitter-Edgecombe, Maureen; Fuster, Joaquín M.

    2014-01-01

    Traumatic brain injury (TBI) is associated with deficits in memory for the content of completed activities. However, TBI groups have shown variable memory for the temporal order of activities. We sought to clarify the conditions under which temporal order memory for activities is intact following TBI. Additionally, we evaluated activity source memory and the relationship between activity memory and functional outcome in TBI participants. Thus, we completed a study of activity memory with 18 severe TBI survivors and 18 healthy age- and education-matched comparison participants. Both groups performed eight activities and observed eight activities that were fashioned after routine daily tasks. Incidental encoding conditions for activities were utilized. The activities were drawn from two counterbalanced lists, and both performance and observation were randomly determined and interspersed. After all of the activities were completed, content memory (recall and recognition), source memory (conditional source identification), and temporal order memory (correlation between order reconstruction and actual order) for the activities were assessed. Functional ability was assessed via the Community Integration Questionnaire (CIQ). In terms of content memory, TBI participants recalled and recognized fewer activities than comparison participants. Recognition of performed and observed activities was strongly associated with social integration on the CIQ. There were no between- or within-group differences in temporal order or source memory, although source memory performances were near ceiling. The findings were interpreted as suggesting that temporal order memory following TBI is intact under conditions of both purposeful activity completion and incidental encoding, and that activity memory is related to functional outcomes following TBI. PMID:24524393

  13. The course of posttraumatic stress symptoms and functional impairment following a disaster: what is the lasting influence of acute vs. ongoing traumatic events and stressors?

    PubMed Central

    Cerdá, M.; Bordelois, P.M.; Galea, S.; Norris, F.; Tracy, M.; Koenen, K.C.

    2012-01-01

    Purpose Ongoing traumatic events and stressors, rather than acute sources of trauma, may shape long-term post-disaster mental health. The purpose of this study was to compare the influence of acute hurricane-related exposures and ongoing post-hurricane exposures on the short- and long-term course of posttraumatic stress symptoms (PTSS) and functional impairment (FI). Methods A random sample of adults (n=658) in Galveston and Chambers Counties, Texas, was selected 2–6 months after Hurricane Ike and interviewed 3 times over eighteen months. Hurricane-related exposures included traumatic events such as death of a family member due to the hurricane and stressors such as loss/damage to personal property due to the hurricane. Post-hurricane exposures included traumatic events such as sexual assault and stressors such as divorce or serious financial problems. Results Experiencing an acute hurricane-related traumatic event or stressor was associated with initial post-hurricane PTSS [RR=1.92(95% CI=1.13–3.26) and RR=1.62(1.36–1.94), respectively] and FI [RR=1.76; (1.05–2.97) and RR=1.74(1.46–2.08)], respectively, and acute hurricane-related stressors were associated with a higher rate of increase in FI over time [RR=1.09; (1.01–1.19)]. In contrast, ongoing post-hurricane daily stressors were not associated within initial PTSS and FI, but were associated with PTSS and FI at the second and third interviews. Conclusions While immediate postdisaster interventions may influence short-term mental health, investment in the prevention of ongoing stressors may be instrumental to manage long-term mental health status. PMID:22878832

  14. Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography

    PubMed Central

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M.; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D.; Chen, Zhongping

    2016-01-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement. PMID:26977365

  15. Fully distributed absolute blood flow velocity measurement for middle cerebral arteries using Doppler optical coherence tomography.

    PubMed

    Qi, Li; Zhu, Jiang; Hancock, Aneeka M; Dai, Cuixia; Zhang, Xuping; Frostig, Ron D; Chen, Zhongping

    2016-02-01

    Doppler optical coherence tomography (DOCT) is considered one of the most promising functional imaging modalities for neuro biology research and has demonstrated the ability to quantify cerebral blood flow velocity at a high accuracy. However, the measurement of total absolute blood flow velocity (BFV) of major cerebral arteries is still a difficult problem since it is related to vessel geometry. In this paper, we present a volumetric vessel reconstruction approach that is capable of measuring the absolute BFV distributed along the entire middle cerebral artery (MCA) within a large field-of-view. The Doppler angle at each point of the MCA, representing the vessel geometry, is derived analytically by localizing the artery from pure DOCT images through vessel segmentation and skeletonization. Our approach could achieve automatic quantification of the fully distributed absolute BFV across different vessel branches. Experiments on rodents using swept-source optical coherence tomography showed that our approach was able to reveal the consequences of permanent MCA occlusion with absolute BFV measurement.

  16. Induction of settlement in mussel (Perna canaliculus) larvae by vessel noise.

    PubMed

    Wilkens, S L; Stanley, J A; Jeffs, A G

    2012-01-01

    Underwater sound plays an important role in the settlement behaviour of many coastal organisms. Large steel-hulled vessels are known to be a major source of underwater sound in the marine environment. The possibility that underwater sound from vessels may promote biofouling of hulls through triggering natural larval settlement cues was investigated for the mussel, Perna canaliculus. The mussel larvae showed significantly faster settlement when exposed to the underwater noise produced by a 125-m long steel-hulled passenger and freight ferry. Median time to attachment on the substrata (ie settlement) was reduced by 22% and the time taken for all experimental larvae to settle was reduced by 40% relative to a silent control. There was no difference in the survival of the mussel larvae among the various noise treatments. The decrease in settlement time of the mussel larvae appeared to correlate with the intensity of the vessel sound, suggesting that underwater sound emanating from vessels may be an important factor in exacerbating hull fouling by mussels.

  17. Underwater noise pollution in a coastal tropical environment.

    PubMed

    Bittencourt, L; Carvalho, R R; Lailson-Brito, J; Azevedo, A F

    2014-06-15

    Underwater noise pollution has become a major concern in marine habitats. Guanabara Bay, southeastern Brazil, is an impacted area of economic importance with constant vessel traffic. One hundred acoustic recording sessions took place over ten locations. Sound sources operating within 1 km radius of each location were quantified during recordings. The highest mean sound pressure level near the surface was 111.56±9.0 dB re 1 μPa at the frequency band of 187 Hz. Above 15 kHz, the highest mean sound pressure level was 76.21±8.3 dB re 1 μPa at the frequency 15.89 kHz. Noise levels correlated with number of operating vessels and vessel traffic composition influenced noise profiles. Shipping locations had the highest noise levels, while small vessels locations had the lowest noise levels. Guanabara Bay showed noise pollution similar to that of other impacted coastal regions, which is related to shipping and vessel traffic. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Quality of drinking-water at source and point-of-consumption--drinking cup as a high potential recontamination risk: a field study in Bolivia.

    PubMed

    Rufener, Simonne; Mäusezahl, Daniel; Mosler, Hans-Joachim; Weingartner, Rolf

    2010-02-01

    In-house contamination of drinking-water is a persistent problem in developing countries. This study aimed at identifying critical points of contamination and determining the extent of recontamination after water treatment. In total, 81 households were visited, and 347 water samples from their current sources of water, transport vessels, treated water, and drinking vessels were analyzed. The quality of water was assessed using Escherichia coli as an indicator for faecal contamination. The concentration of E. coli increased significantly from the water source [median=0 colony-forming unit (CFU)/100 mL, interquartile range (IQR: 0-13)] to the drinking cup (median=8 CFU/100 mL; IQR: 0-550; n=81, z=-3.7, p<0.001). About two-thirds (34/52) of drinking vessels were contaminated with E. coli. Although boiling and solar disinfection of water (SODIS) improved the quality of drinking-water (median=0 CFU/100 mL; IQR: 0-0.05), recontamination at the point-of-consumption significantly reduced the quality of water in the cups (median=8, IQR: 0-500; n=45, z=-2.4, p=0.015). Home-based interventions in disinfection of water may not guarantee health benefits without complementary hygiene education due to the risk of posttreatment contamination.

  19. SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY REVEALS INTERNAL LIMITING MEMBRANE PEELING ALTERS DEEP RETINAL VASCULATURE.

    PubMed

    Michalewska, Zofia; Nawrocki, Jerzy

    2018-04-30

    To describe morphology of retinal and choroidal vessels in swept-source optical coherence tomography angiography before and after vitrectomy with the temporal inverted internal limiting membrane (ILM) flap technique for full-thickness macular holes. Prospective, observational study of 36 eyes of 33 patients with full-thickness macular holes swept-source optical coherence tomography angiography was performed in patients before and 1 month after vitrectomy. Vitrectomy with the temporal inverted ILM flap technique was performed. In this method, ILM is peeled only at one side of the fovea. An ILM flap is created to cover the macular hole. Comparison of retina vasculature in the areas of ILM peeling vs. no ILM peeling at 1 and 3 months after successful vitrectomy was performed. The study demonstrated lower density of vessels in the deep retinal plexus in the area where ILM was peeled as compared to the rest of the fovea. Visual acuity and central retinal thickness 1 month after surgery correlates with fovea avascular zone diameter in deep retinal layers at the same time point (P = 0.001). This study confirmed that ILM peeling might alter blood flow in deep retinal vessels below the peeling area in the early postoperative period. The area of the fovea avascular zone corresponds to functional results at the same time point.

  20. Characterizing large river sounds: Providing context for understanding the environmental effects of noise produced by hydrokinetic turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevelhimer, Mark S.; Deng, Z. Daniel; Scherelis, Constantin

    2016-01-01

    Underwater noise associated with the installation and operation of hydrokinetic turbines in rivers and tidal zones presents a potential environmental concern for fish and marine mammals. Comparing the spectral quality of sounds emitted by hydrokinetic turbines to natural and other anthropogenic sound sources is an initial step at understanding potential environmental impacts. Underwater recordings were obtained from passing vessels of different sizes and other underwater sound sources in both static and flowing waters. Static water measurements were taken in a lake with minimal background noise. Flowing water measurements were taken at a previously proposed deployment site for hydrokinetic turbines onmore » the Mississippi River, where the sound of flowing water is included in background measurements. The size of vessels measured ranged from a small fishing boat with a 60 HP outboard motor to an 18-unit barge train being pushed upstream by tugboat. As expected, large vessels with large engines created the highest sound levels, and when compared to the sound created by an operating HK turbine were many times greater. A comparison of sound levels from the same sources at different distances using both spherical and cylindrical sound attenuation functions suggests that spherical model results more closely approximate observed values.« less

  1. 46 CFR 129.375 - System grounding.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Power Sources and Distribution Systems § 129.375 System grounding. (a) If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This connection must be at the main switchboard. (b) On each metallic vessel, a grounded distribution...

  2. 46 CFR 129.375 - System grounding.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Power Sources and Distribution Systems § 129.375 System grounding. (a) If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This connection must be at the main switchboard. (b) On each metallic vessel, a grounded distribution...

  3. 46 CFR 129.375 - System grounding.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Power Sources and Distribution Systems § 129.375 System grounding. (a) If a grounded distribution system is provided, there must be only one connection to ground, regardless of the number of power sources. This connection must be at the main switchboard. (b) On each metallic vessel, a grounded distribution...

  4. Muscle-splitting approach to superior and inferior gluteal vessels: versatile source of recipient vessels for free-tissue transfer to sacral, gluteal, and ischial regions.

    PubMed

    Park, S

    2000-07-01

    The superior gluteal vessel has been reported as a recipient in free-tissue transfer for the coverage of complex soft-tissue defects in the lumbosacral region, where a suitable recipient vessel is difficult to find. The characteristics of proximity, vessel caliber, and constancy make the superior gluteal vessel preferable to previously reported recipient vessels. However, there are technical difficulties in microsurgery (e.g., short pedicle length and deep location) and muscle injury (transection of the muscle) associated with use of the superior gluteal vessel. The purpose of this article is to present a modification of an approach to the gluteal vessel to alleviate technical difficulties and minimize muscle injury. From August of 1997 to January of 1999, six patients received microvascular transfer of the latissimus dorsi muscle or myocutaneous flap to the sacral (4) and ischial (2) regions. The causes of defects were tumor (1), trauma (1), and pressure sores (4). A muscle-splitting approach was used on the superior gluteal vessel and was later applied to the inferior gluteal vessel. The gluteus maximus muscle was split as needed in the direction of its fibers, and the perforators were dissected down to the superior or inferior gluteal artery and vein deep into the muscle. The follow-up period ranged from 6 to 22 months, and all of the flaps survived with complete recovery of the lesion. The major drawbacks of using the superior and inferior gluteal vessels can be overcome with the muscle-splitting approach, which provides increased accessibility and additional length to the vascular pedicle while causing minimal injury to the muscle itself. It also proves to be an easy, safe, and reliable method of dissection. When free-tissue transfer to sacral, gluteal, and ischial regions is indicated, the muscle-splitting approach to the superior and inferior gluteal vessels is a recommended option in the selection of a recipient vessel.

  5. Absolute calibration of sniffer probes on Wendelstein 7-X

    NASA Astrophysics Data System (ADS)

    Moseev, D.; Laqua, H. P.; Marsen, S.; Stange, T.; Braune, H.; Erckmann, V.; Gellert, F.; Oosterbeek, J. W.

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m2 per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m2 per MW injected beam power is measured.

  6. Absolute calibration of sniffer probes on Wendelstein 7-X.

    PubMed

    Moseev, D; Laqua, H P; Marsen, S; Stange, T; Braune, H; Erckmann, V; Gellert, F; Oosterbeek, J W

    2016-08-01

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up to 340 kW/m(2) per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m(2) per MW injected beam power is measured.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moseev, D., E-mail: dmitry.moseev@ipp.mpg.de; Laqua, H. P.; Marsen, S.

    Here we report the first measurements of the power levels of stray radiation in the vacuum vessel of Wendelstein 7-X using absolutely calibrated sniffer probes. The absolute calibration is achieved by using calibrated sources of stray radiation and the implicit measurement of the quality factor of the Wendelstein 7-X empty vacuum vessel. Normalized absolute calibration coefficients agree with the cross-calibration coefficients that are obtained by the direct measurements, indicating that the measured absolute calibration coefficients and stray radiation levels in the vessel are valid. Close to the launcher, the stray radiation in the empty vessel reaches power levels up tomore » 340 kW/m{sup 2} per MW injected beam power. Furthest away from the launcher, i.e., half a toroidal turn, still 90 kW/m{sup 2} per MW injected beam power is measured.« less

  8. Modelling of catastrophic flashing releases.

    PubMed

    Deaves, D M; Gilham, S; Mitchell, B H; Woodburn, P; Shepherd, A M

    2001-11-16

    Several low boiling point materials are stored in closed vessels at ambient temperature, using their own vapour pressure to maintain a liquid state. These materials are often toxic, flammable, or both, and thus any uncontrolled release can have potentially disastrous consequences. There are many ways in which an accidental release can occur, the most severe being due to catastrophic vessel failure. Although not the most common, this mode of failure has the potential to result in an instantaneous loss of the entire vessel inventory in the form of a rapidly expanding, two-phase, vaporising cloud. This paper provides a comprehensive review of the physical processes of existing models and of available experimental and incident data to model such scenarios. Subsequently, this has enabled the development of an improved methodology for the characterisation of the source conditions following catastrophic vessel failures.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Graczyk, D.G.

    The ACL activities covered IFR fuel reprocessing, corium-concrete interactions, environmental samples, wastes, WIPP support, Advanced Photon Source, H-Tc superconductors, EBWR vessel, soils, illegal drug detection, quality control, etc.

  10. Optimization study on structural analyses for the J-PARC mercury target vessel

    NASA Astrophysics Data System (ADS)

    Guan, Wenhai; Wakai, Eiichi; Naoe, Takashi; Kogawa, Hiroyuki; Wakui, Takashi; Haga, Katsuhiro; Takada, Hiroshi; Futakawa, Masatoshi

    2018-06-01

    The spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC) mercury target vessel is used for various materials science studies, work is underway to achieve stable operation at 1 MW. This is very important for enhancing the structural integrity and durability of the target vessel, which is being developed for 1 MW operation. In the present study, to reduce thermal stress and relax stress concentrations more effectively in the existing target vessel in J-PARC, an optimization approach called the Taguchi method (TM) is applied to thermo-mechanical analysis. The ribs and their relative parameters, as well as the thickness of the mercury vessel and shrouds, were selected as important design parameters for this investigation. According to the analytical results of 18 model types designed using the TM, the optimal design was determined. It is characterized by discrete ribs and a thicker vessel wall than the current design. The maximum thermal stresses in the mercury vessel and the outer shroud were reduced by 14% and 15%, respectively. Furthermore, it was indicated that variations in rib width, left/right rib intervals, and shroud thickness could influence the maximum thermal stress performance. It is therefore concluded that the TM was useful for optimizing the structure of the target vessel and to reduce the thermal stress in a small number of calculation cases.

  11. Spatial Metrics of Tumour Vascular Organisation Predict Radiation Efficacy in a Computational Model

    PubMed Central

    Scott, Jacob G.

    2016-01-01

    Intratumoural heterogeneity is known to contribute to poor therapeutic response. Variations in oxygen tension in particular have been correlated with changes in radiation response in vitro and at the clinical scale with overall survival. Heterogeneity at the microscopic scale in tumour blood vessel architecture has been described, and is one source of the underlying variations in oxygen tension. We seek to determine whether histologic scale measures of the erratic distribution of blood vessels within a tumour can be used to predict differing radiation response. Using a two-dimensional hybrid cellular automaton model of tumour growth, we evaluate the effect of vessel distribution on cell survival outcomes of simulated radiation therapy. Using the standard equations for the oxygen enhancement ratio for cell survival probability under differing oxygen tensions, we calculate average radiation effect over a range of different vessel densities and organisations. We go on to quantify the vessel distribution heterogeneity and measure spatial organization using Ripley’s L function, a measure designed to detect deviations from complete spatial randomness. We find that under differing regimes of vessel density the correlation coefficient between the measure of spatial organization and radiation effect changes sign. This provides not only a useful way to understand the differences seen in radiation effect for tissues based on vessel architecture, but also an alternate explanation for the vessel normalization hypothesis. PMID:26800503

  12. Mortality at Music Festivals: Academic and Grey Literature for Case Finding.

    PubMed

    Turris, Sheila A; Lund, Adam

    2017-02-01

    Deaths at music festivals are not infrequently reported in the media; however, the true mortality burden is difficult to determine as the deaths are not yet systematically documented in the academic literature. This was a literature search for case examples using academic and gray literature sources, employing both retrospective and prospective searches of media sources from 1999-2014. The gray literature documents a total of 722 deaths, including traumatic (594/722; 82%) and non-traumatic (128/722; 18%) causes. Fatalities were caused by trampling (n=479), motor-vehicle-related (n=39), structural collapses (n=28), acts of terror (n=26), drowning (n=8), assaults (n=6), falls (n=5), hanging (n=2), and thermal injury (n=2). Non-traumatic deaths included overdoses (n=96/722; 13%), environmental causes (n=8/722; 1%), natural causes (n=10/722; 1%), and unknown/not reported (n=14/722; 2%). The majority of non-trauma-related deaths were related to overdose (75%). The academic literature documents trauma-related deaths (n=368) and overdose-related deaths (n=12). One hundred percent of the trauma-related deaths reported in the academic literature also were reported in the gray literature (n=368). Mortality rates cannot be reported as the total attendance at events is not known. The methodology presented in this manuscript confirms that deaths occur not uncommonly at music festivals, and it represents a starting point in the documentation and surveillance of mortality. Turris SA , Lund A . Mortality at music festivals: academic and grey literature for case finding. Prehosp Disaster Med. 2017;32(1):58-63.

  13. Hemipelvectomy images of loss caused by war

    PubMed Central

    Salamon, Tal; Kassis, Shokrey; Lerner, Alexander

    2014-01-01

    As we treat our 230th patient from the Syrian conflict, the pathology we see is more debilitating and the humanitarian needs of the wounded have become even more obvious. This case presents some graphic images of the realities of war. Care in the most advanced units cannot restore broken limbs, let alone broken lives. We present a case of a young war-injured man, who suffered severe crush injury to the pelvis and lower limb, arriving at our medical facility after a delay of hours. The lower limb was shattered from the pelvis down (essentially a traumatic hemipelvectomy). His life had been saved in Syria by ligation of the femoral vessels in an unknown facility by an unknown medical team. On arrival in a centre in Israel for definitive care of an unsalvageable leg, formal hemipelvectomy was performed. PMID:25008336

  14. Plasmalemma vesicle-associated protein: A crucial component of vascular homeostasis

    PubMed Central

    Guo, Ling; Zhang, Hongyan; Hou, Yinglong; Wei, Tianshu; Liu, Ju

    2016-01-01

    Endothelial subcellular structures, including caveolae, fenestrae and transendothelial channels, are crucial for regulating microvascular function. Plasmalemma vesicle-associated protein (PLVAP) is an endothelial cell-specific protein that forms the stomatal and fenestral diaphragms of blood vessels and regulates basal permeability, leukocyte migration and angiogenesis. Loss of PLVAP in mice leads to premature mortality due to disrupted homeostasis. Evidence from previous studies suggested that PLVAP is involved in cancer, traumatic spinal cord injury, acute ischemic brain disease, transplant glomerulopathy, Norrie disease and diabetic retinopathy. Specifically, PLVAP expression has been demonstrated to be upregulated in these diseases, accompanied by pro-angiogenic or pro-inflammatory responses. Therefore, PLVAP is considered a novel therapeutic target, in addition to an endothelial cell marker. The present review summarizes the structure and functions of PLVAP, and its roles in pathophysiological processes. PMID:27602081

  15. 46 CFR 112.15-1 - Temporary emergency loads.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... AND POWER SYSTEMS Emergency Loads § 112.15-1 Temporary emergency loads. On vessels required by § 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: (a...

  16. 46 CFR 112.15-1 - Temporary emergency loads.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... AND POWER SYSTEMS Emergency Loads § 112.15-1 Temporary emergency loads. On vessels required by § 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: (a...

  17. 46 CFR 112.15-1 - Temporary emergency loads.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... AND POWER SYSTEMS Emergency Loads § 112.15-1 Temporary emergency loads. On vessels required by § 112.05-5(a) to have a temporary emergency power source, the following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source: (a...

  18. Severe traumatic injury during long duration spaceflight: Light years beyond ATLS.

    PubMed

    Kirkpatrick, Andrew W; Ball, Chad G; Campbell, Mark; Williams, David R; Parazynski, Scott E; Mattox, Kenneth L; Broderick, Timothy J

    2009-03-25

    Traumatic injury strikes unexpectedly among the healthiest members of the human population, and has been an inevitable companion of exploration throughout history. In space flight beyond the Earth's orbit, NASA considers trauma to be the highest level of concern regarding the probable incidence versus impact on mission and health. Because of limited resources, medical care will have to focus on the conditions most likely to occur, as well as those with the most significant impact on the crew and mission. Although the relative risk of disabling injuries is significantly higher than traumatic deaths on earth, either issue would have catastrophic implications during space flight. As a result this review focuses on serious life-threatening injuries during space flight as determined by a NASA consensus conference attended by experts in all aspects of injury and space flight.In addition to discussing the impact of various mission profiles on the risk of injury, this manuscript outlines all issues relevant to trauma during space flight. These include the epidemiology of trauma, the pathophysiology of injury during weightlessness, pre-hospital issues, novel technologies, the concept of a space surgeon, appropriate training for a space physician, resuscitation of injured astronauts, hemorrhage control (cavitary and external), surgery in space (open and minimally invasive), postoperative care, vascular access, interventional radiology and pharmacology.Given the risks and isolation inherent in long duration space flight, a well trained surgeon and/or surgical capability will be required onboard any exploration vessel. More specifically, a broadly-trained surgically capable emergency/critical care specialist with innate capabilities to problem-solve and improvise would be desirable. It will be the ultimate remote setting, and hopefully one in which the most advanced of our societies' technologies can be pre-positioned to safeguard precious astronaut lives. Like so many previous space-related technologies, these developments will also greatly improve terrestrial care on earth.

  19. Severe traumatic injury during long duration spaceflight: Light years beyond ATLS

    PubMed Central

    Kirkpatrick, Andrew W; Ball, Chad G; Campbell, Mark; Williams, David R; Parazynski, Scott E; Mattox, Kenneth L; Broderick, Timothy J

    2009-01-01

    Traumatic injury strikes unexpectedly among the healthiest members of the human population, and has been an inevitable companion of exploration throughout history. In space flight beyond the Earth's orbit, NASA considers trauma to be the highest level of concern regarding the probable incidence versus impact on mission and health. Because of limited resources, medical care will have to focus on the conditions most likely to occur, as well as those with the most significant impact on the crew and mission. Although the relative risk of disabling injuries is significantly higher than traumatic deaths on earth, either issue would have catastrophic implications during space flight. As a result this review focuses on serious life-threatening injuries during space flight as determined by a NASA consensus conference attended by experts in all aspects of injury and space flight. In addition to discussing the impact of various mission profiles on the risk of injury, this manuscript outlines all issues relevant to trauma during space flight. These include the epidemiology of trauma, the pathophysiology of injury during weightlessness, pre-hospital issues, novel technologies, the concept of a space surgeon, appropriate training for a space physician, resuscitation of injured astronauts, hemorrhage control (cavitary and external), surgery in space (open and minimally invasive), postoperative care, vascular access, interventional radiology and pharmacology. Given the risks and isolation inherent in long duration space flight, a well trained surgeon and/or surgical capability will be required onboard any exploration vessel. More specifically, a broadly-trained surgically capable emergency/critical care specialist with innate capabilities to problem-solve and improvise would be desirable. It will be the ultimate remote setting, and hopefully one in which the most advanced of our societies' technologies can be pre-positioned to safeguard precious astronaut lives. Like so many previous space-related technologies, these developments will also greatly improve terrestrial care on earth. PMID:19320976

  20. Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas.

    PubMed

    Jensen, Jonas; Olesen, Jacob Bjerring; Stuart, Matthias Bo; Hansen, Peter Møller; Nielsen, Michael Bachmann; Jensen, Jørgen Arendt

    2016-08-01

    A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. BDNF function as a potential mediator of bipolar disorder and post-traumatic stress disorder comorbidity

    PubMed Central

    Rakofsky, JJ; Ressler, KJ; Dunlop, BW

    2013-01-01

    Bipolar disorder (BD) and post-traumatic stress disorder (PTSD) frequently co-occur among psychiatric patients, leading to increased morbidity and mortality. Brain-derived neurotrophic factor (BDNF) function is associated with core characteristics of both BD and PTSD. We propose a neurobiological model that underscores the role of reduced BDNF function resulting from several contributing sources, including the met variant of the BDNF val66met (rs6265) single-nucleotide polymorphism, trauma-induced epigenetic regulation and current stress, as a contributor to the onset of both illnesses within the same person. Further studies are needed to evaluate the genetic association between the val66met allele and the BD-PTSD population, along with central/peripheral BDNF levels and epigenetic patterns of BDNF gene regulation within these patients. PMID:21931317

  2. Advances in Imaging and Management Trends of Traumatic Aortic Injuries.

    PubMed

    Nagpal, Prashant; Mullan, Brian F; Sen, Indrani; Saboo, Sachin S; Khandelwal, Ashish

    2017-05-01

    Acute traumatic aortic injury (ATAI) is a life-threatening injury. CT is the imaging tool of choice, and the knowledge of direct and indirect signs of injury, grading system, and current management protocol helps the emergency radiologist to better identify and classify the injury and provide additional details that can impact management options. Newer dual-source CT technology with ultrafast acquisition speed has also influenced the appropriate protocol for imaging in patients with suspected ATAI. This review highlights the imaging protocol in patients with blunt trauma, CT appearance and grading systems of ATAI, management options, and the role of the multidisciplinary team in the management of these patients. We also briefly review the current literature on the definition, treatment, and follow-up protocol in patients with minimal aortic injury.

  3. Evolution of Instrumentation for the Study of Gas-Phase Ion/Ion Chemistry via Mass Spectrometry

    PubMed Central

    Xia, Yu; McLuckey, Scott A.

    2008-01-01

    The scope of gas phase ion/ion chemistry accessible to mass spectrometry is largely defined by the available tools. Due to the development of novel instrumentation, a wide range of reaction phenomenologies have been noted, many of which have been studied extensively and exploited for analytical applications. This perspective presents the development of mass spectrometry-based instrumentation for the study of the gas phase ion/ion chemistry in which at least one of the reactants is multiply-charged. The instrument evolution is presented within the context of three essential elements required for any ion/ion reaction study: the ionization source(s), the reaction vessel or environment, and the mass analyzer. Ionization source arrangements have included source combinations that allow for reactions between multiply charged ions of one polarity and singly charged ions of opposite polarity, arrangements that enable the study of reactions of multiply charged ions of opposite polarity, and most recently, arrangements that allow for ion formation from more than two ion sources. Gas phase ion/ion reaction studies have been performed at near atmospheric pressure in flow reactor designs and within electrodynamic ion traps operated in the mTorr range. With ion trap as a reaction vessel, ionization and reaction processes can be independently optimized and ion/ion reactions can be implemented within the context of MSn experiments. Spatial separation of the reaction vessel from the mass analyzer allows for the use of any form of mass analysis in conjunction with ion/ion reactions. Time-of-flight mass analysis, for example, has provided significant improvements in mass analysis figures of merit relative to mass filters and ion traps. PMID:18083527

  4. Reactor process using metal oxide ceramic membranes

    DOEpatents

    Anderson, Marc A.

    1994-01-01

    A reaction vessel for use in photoelectrochemical reactions includes as its reactive surface a metal oxide porous ceramic membrane of a catalytic metal such as titanium. The reaction vessel includes a light source and a counter electrode. A provision for applying an electrical bias between the membrane and the counter electrode permits the Fermi levels of potential reaction to be favored so that certain reactions may be favored in the vessel. The electrical biasing is also useful for the cleaning of the catalytic membrane. Also disclosed is a method regenerating a porous metal oxide ceramic membrane used in a photoelectrochemical catalytic process by periodically removing the reactants and regenerating the membrane using a variety of chemical, thermal, and electrical techniques.

  5. SNS Central Helium Liquefier spare Carbon Bed installation and commissioning

    NASA Astrophysics Data System (ADS)

    DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.

    2017-12-01

    The Spallation Neutron Source (SNS) Central Helium Liquefier (CHL) at Oak Ridge National Laboratory (ORNL) has been without major operations downtime since operations were started back in 2006. This system utilizes a vessel filled with activated carbon as the final major component to remove oil vapor from the compressed helium circuit prior to insertion into the system’s cryogenic cold box. The need for a spare carbon bed at SNS due to the variability of carbon media lifetime calculation to adsorption efficiency will be discussed. The fabrication, installation and commissioning of this spare carbon vessel will be presented. The novel plan for connecting the spare carbon vessel piping to the existing infrastructure will be presented.

  6. Prospective Risk Factors for Adolescent PTSD: Sources of Differential Exposure and Differential Vulnerability

    ERIC Educational Resources Information Center

    Milan, Stephanie; Zona, Kate; Acker, Jenna; Turcios-Cotto, Viana

    2013-01-01

    There are two types of risk factors for developing PTSD: factors that increase the likelihood of experiencing a potentially traumatizing event and factors that increase the likelihood of developing symptoms following such events. Using prospective data over a two-year period from a large, diverse sample of urban adolescents (n = 1242, Mean age =…

  7. Imaging of cardiovascular dynamics in early mouse embryos with swept source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Larina, Irina V.; Liebling, Michael; Dickinson, Mary E.; Larin, Kirill V.

    2009-02-01

    Congenital cardiovascular defects are very common, occurring in 1% of live births, and cardiovascular failures are the leading cause of birth defect-related deaths in infants. To improve diagnostics, prevention and treatment of cardiovascular abnormalities, we need to understand not only how cells form the heart and vessels but also how physical factors such as heart contraction and blood flow influence heart development and changes in the circulatory network. Mouse models are an excellent resource for studying cardiovascular development and disease because of the resemblance to humans, rapid generation time, and availability of mutants with cardiovascular defects linked to human diseases. In this work, we present results on development and application of Doppler Swept Source Optical Coherence Tomography (DSS-OCT) for imaging of cardiovascular dynamics and blood flow in the mouse embryonic heart and vessels. Our studies demonstrated that the spatial and temporal resolution of the DSS-OCT makes it possible to perform sensitive measurements of heart and vessel wall movements and to investigate how contractile waves facilitate the movement of blood through the circulatory system.

  8. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.

    1996-03-26

    Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.

  9. Characterizing phantom arteries with multi-channel laser ultrasonics and photo-acoustics.

    PubMed

    Johnson, Jami L; van Wijk, Kasper; Sabick, Michelle

    2014-03-01

    Multi-channel photo-acoustic and laser ultrasonic waves are used to sense the characteristics of proxies for healthy and diseased vessels. The acquisition system is non-contacting and non-invasive with a pulsed laser source and a laser vibrometer detector. As the wave signatures of our targets are typically low in amplitude, we exploit multi-channel acquisition and processing techniques. These are commonly used in seismology to improve the signal-to-noise ratio of data. We identify vessel proxies with a diameter on the order of 1 mm, at a depth of 18 mm. Variations in scattered and photo-acoustic signatures are related to differences in vessel wall properties and content. The methods described have the potential to improve imaging and better inform interventions for atherosclerotic vessels, such as the carotid artery. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libkind, M.; Bertolini, L.; Duffy, P.

    As part of the research and development effort for a 4th generation light source, we have designed a 4-meter long Free-Electron Laser (FEL) undulator. The undulator will be installed at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory to conduct a Self-Amplified Spontaneous Emission (SASE) demonstration. The demonstration is called VISA, which stands for "Visible to Infrared SASE Amplifier." The undulator consists of 440 permanent dipole magnets per meter which are supported and aligned on a precision strongback. Focusing and defocusing permanent quadrupole magnets are also supported by the strongback. Each of the 4 one-meter sections of undulator aremore » kinematically supported and housed within the vacuum vessel. The undulator and the vacuum vessel are supported independently to eliminate undulator misalignment during vacuum pump-down of the vessel. We describe the design requirements and features of the undulator, vacuum vessel and support system.« less

  11. Self-contained cryogenic gas sampling apparatus and method

    DOEpatents

    McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.

    1996-01-01

    Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.

  12. CT evaluation of thoracic infections after major trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirvis, S.E.; Rodriguez, A.; Whitley, N.O.

    1985-06-01

    Thirty-seven septic patients with major multisystem trauma were evaluated by computed tomography (CT) to identify possible thoracic sources of infection. CT was 72% accurate in the diagnosis of empyema and 95% accurate in the diagnosis of lung abscess. While CT proved useful in demonstrating these sites of thoracic infections in septic trauma victims, the presence of concurrent thoracic pathology, particularly loculated hemothorax or hemopneumothorax and traumatic lung cysts with hemorrhage or surrounding parenchymal consolidation, introduced sources of diagnostic error. CT also proved helpful in guiding appropriate revisions of malpositioned and occluded thoracostomy tubes.

  13. Inference of vessel intent and behaviour for maritime security operations

    NASA Astrophysics Data System (ADS)

    van den Broek, Bert; Smith, Arthur; den Breejen, Eric; van de Voorde, Imelda

    2014-10-01

    Coastguard and Navy assets are increasingly involved in Maritime Security Operations (MSO) for countering piracy, weapons and drugs smuggling, terrorism and illegal trafficking. Persistent tracking of vessels in interrupted time series over long distances and the modelling of intent and behaviour from multiple data sources are key enablers for Situation Assessment in MSO. Results of situation assessment are presented for AIS/VTS observations in the Dutch North Sea and for simulated scenarios in the Gulf of Oman.

  14. Stem Hydraulic Conductivity depends on the Pressure at Which It Is Measured and How This Dependence Can Be Used to Assess the Tempo of Bubble Pressurization in Recently Cavitated Vessels1[OPEN

    PubMed Central

    Liu, Jinyu; Tyree, Melvin T.

    2015-01-01

    Cavitation of water in xylem vessels followed by embolism formation has been authenticated for more than 40 years. Embolism formation involves the gradual buildup of bubble pressure (air) to atmospheric pressure as demanded by Henry’s law of equilibrium between gaseous and liquid phases. However, the tempo of pressure increase has not been quantified. In this report, we show that the rate of pressurization of embolized vessels is controlled by both fast and slow kinetics, where both tempos are controlled by diffusion but over different spatial scales. The fast tempo involves a localized diffusion from endogenous sources: over a distance of about 0.05 mm from water-filled wood to the nearest embolized vessels; this process, in theory, should take <2 min. The slow tempo involves diffusion of air from exogenous sources (outside the stem). The latter diffusion process is slower because of the increased distance of diffusion of up to 4 mm. Radial diffusion models and experimental measurements both confirm that the average time constant is >17 h, with complete equilibrium requiring 1 to 2 d. The implications of these timescales for the standard methods of measuring percentage loss of hydraulic conductivity are discussed in theory and deserve more research in future. PMID:26468516

  15. Stem Hydraulic Conductivity depends on the Pressure at Which It Is Measured and How This Dependence Can Be Used to Assess the Tempo of Bubble Pressurization in Recently Cavitated Vessels.

    PubMed

    Wang, Yujie; Liu, Jinyu; Tyree, Melvin T

    2015-12-01

    Cavitation of water in xylem vessels followed by embolism formation has been authenticated for more than 40 years. Embolism formation involves the gradual buildup of bubble pressure (air) to atmospheric pressure as demanded by Henry's law of equilibrium between gaseous and liquid phases. However, the tempo of pressure increase has not been quantified. In this report, we show that the rate of pressurization of embolized vessels is controlled by both fast and slow kinetics, where both tempos are controlled by diffusion but over different spatial scales. The fast tempo involves a localized diffusion from endogenous sources: over a distance of about 0.05 mm from water-filled wood to the nearest embolized vessels; this process, in theory, should take <2 min. The slow tempo involves diffusion of air from exogenous sources (outside the stem). The latter diffusion process is slower because of the increased distance of diffusion of up to 4 mm. Radial diffusion models and experimental measurements both confirm that the average time constant is >17 h, with complete equilibrium requiring 1 to 2 d. The implications of these timescales for the standard methods of measuring percentage loss of hydraulic conductivity are discussed in theory and deserve more research in future. © 2015 American Society of Plant Biologists. All Rights Reserved.

  16. Vessel noise cuts down communication space for vocalizing fish and marine mammals.

    PubMed

    Putland, Rosalyn L; Merchant, Nathan D; Farcas, Adrian; Radford, Craig A

    2018-04-01

    Anthropogenic noise across the world's oceans threatens the ability of vocalizing marine species to communicate. Some species vocalize at key life stages or whilst foraging, and disruption to the acoustic habitat at these times could lead to adverse consequences at the population level. To investigate the risk of these impacts, we investigated the effect of vessel noise on the communication space of the Bryde's whale Balaenoptera edeni, an endangered species which vocalizes at low frequencies, and bigeye Pempheris adspersa, a nocturnal fish species which uses contact calls to maintain group cohesion while foraging. By combining long-term acoustic monitoring data with AIS vessel-tracking data and acoustic propagation modelling, the impact of vessel noise on their communication space was determined. Routine vessel passages cut down communication space by up to 61.5% for bigeyes and 87.4% for Bryde's whales. This influence of vessel noise on communication space exceeded natural variability for between 3.9 and 18.9% of the monitoring period. Additionally, during the closest point of approach of a large commercial vessel, <10 km from the listening station, the communication space of both species was reduced by a maximum of 99% compared to the ambient soundscape. These results suggest that vessel noise reduces communication space beyond the evolutionary context of these species and may have chronic effects on these populations. To combat this risk, we propose the application or extension of ship speed restrictions in ecologically significant areas, since our results indicate a reduction in sound source levels for vessels transiting at lower speeds. © 2017 John Wiley & Sons Ltd.

  17. Fine-grained visual marine vessel classification for coastal surveillance and defense applications

    NASA Astrophysics Data System (ADS)

    Solmaz, Berkan; Gundogdu, Erhan; Karaman, Kaan; Yücesoy, Veysel; Koç, Aykut

    2017-10-01

    The need for capabilities of automated visual content analysis has substantially increased due to presence of large number of images captured by surveillance cameras. With a focus on development of practical methods for extracting effective visual data representations, deep neural network based representations have received great attention due to their success in visual categorization of generic images. For fine-grained image categorization, a closely related yet a more challenging research problem compared to generic image categorization due to high visual similarities within subgroups, diverse applications were developed such as classifying images of vehicles, birds, food and plants. Here, we propose the use of deep neural network based representations for categorizing and identifying marine vessels for defense and security applications. First, we gather a large number of marine vessel images via online sources grouping them into four coarse categories; naval, civil, commercial and service vessels. Next, we subgroup naval vessels into fine categories such as corvettes, frigates and submarines. For distinguishing images, we extract state-of-the-art deep visual representations and train support-vector-machines. Furthermore, we fine tune deep representations for marine vessel images. Experiments address two scenarios, classification and verification of naval marine vessels. Classification experiment aims coarse categorization, as well as learning models of fine categories. Verification experiment embroils identification of specific naval vessels by revealing if a pair of images belongs to identical marine vessels by the help of learnt deep representations. Obtaining promising performance, we believe these presented capabilities would be essential components of future coastal and on-board surveillance systems.

  18. 29 CFR 1919.22 - Requirements governing braking devices and power sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Requirements governing braking devices and power sources. All types of winches and cranes shall be provided... winch, or electric cranes shall be equipped so that a failure of the electric power shall stop the... electric winches and cranes during the tests shall be taken from the vessel's circuits. Shore current may...

  19. 46 CFR 190.05-15 - Segregation of spaces containing the emergency source of electric power.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... electric power. 190.05-15 Section 190.05-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 190.05-15 Segregation of spaces containing the emergency source of electric power. (a) When a compartment containing the...

  20. En face choroidal vascular feature imaging in acute and chronic central serous chorioretinopathy using swept source optical coherence tomography.

    PubMed

    Lee, Won June; Lee, Jung Wook; Park, Seung Hun; Lee, Byung Ro

    2017-05-01

    To evaluate the variable depth tomographic features of choroidal vasculature in acute and chronic central serous chorioretinopathy (CSC) using swept source optical coherence tomography (SS-OCT) en face imaging. We retrospectively reviewed the en face SS-OCT images of 29 patients that presented with acute (12 eyes) or chronic (17 eyes) CSC. All of the patient eyes underwent 6×6 macular scans with SS-OCT (DRI OCT-1, Topcon, Tokyo, Japan), fluorescein angiography and indocyanine green angiography. The en face image was used to investigate the choroidal vasculature of each layer. Moreover, we determined that some parts corresponded to choriocapillaris and Sattler's layer attenuation, whereas choroidal vessel dilatation was associated with Haller's layer. At Haller's layer level, choroidal vessel dilatation was observed in 11 of 12 acute CSC (91.7%) and 15 of 17 chronic CSC (88.2%). In acute CSC, choroidal vessel dilatation was divided into focal (9/11; 81.8%) and diffuse (2/11; 18.2%) patterns. The chronic CSC cases demonstrated different patterns of choroidal vessel dilatation: focal (5/15; 33.3%) and diffuse (10/15; 66.6%). Ten of the acute CSC eyes (83.3%) and 14 of the chronic CSC eyes (82.4%) were found to have obscured choriocapillaris and Sattler's layers on en face imaging. En face imaging of SS-OCT is useful when combined with angiography in CSC for evaluating choroidal vessel dilatation at Haller's layer and to identify obscured upper layers. We identified different choroidal vessel dilatation patterns between acute and chronic CSC. These findings might be useful for pathophysiological understanding of CSC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Breast cancer and problems with medical interactions: relationships with traumatic stress, emotional self-efficacy, and social support.

    PubMed

    Han, Win T; Collie, Kate; Koopman, Cheryl; Azarow, Jay; Classen, Catherine; Morrow, Gary R; Michel, Betsy; Brennan-O'Neill, Eileen; Spiegel, David

    2005-04-01

    This investigation examined relationships between breast cancer patients' psychosocial characteristics (impact of the illness, traumatic stress symptoms, emotional self-efficacy, and social support) and problems they perceived in their medical interactions and their satisfaction with their physicians. Participants were 352 women enrolled in a multicenter trial of the effects of group therapy for women with recently diagnosed primary breast cancer. The findings reported here are from a cross-sectional analysis of baseline data gathered prior to randomization. Problems interacting with physicians and nurses were associated with greater levels of cancer-related traumatic stress (p < 0.01), less emotional self-efficacy for cancer (p < 0.05), less satisfaction with informational support from family, friends, and spouse, and a tendency to perceive those sources of support as more aversive (p < 0.05). Women who were less satisfied with emotional support from their family, friends and spouse were less likely to feel satisfied with their physicians (p < 0.05). These patient characteristics identify women with primary breast cancer who are likely to experience difficulty in their interactions with nurses and physicians and to be less satisfied with their physicians.

  2. Estimation of the EEG power spectrum using MRI T(2) relaxation time in traumatic brain injury.

    PubMed

    Thatcher, R W; Biver, C; Gomez, J F; North, D; Curtin, R; Walker, R A; Salazar, A

    2001-09-01

    To study the relationship between magnetic resonance imaging (MRI) T(2) relaxation time and the power spectrum of the electroencephalogram (EEG) in long-term follow up of traumatic brain injury. Nineteen channel quantitative electroencephalograms or qEEG, tests of cognitive function and quantitative MRI T(2) relaxation times (qMRI) were measured in 18 mild to severe closed head injured outpatients 2 months to 4.6 years after injury and 11 normal controls. MRI T(2) and the Laplacian of T(2) were then correlated with the power spectrum of the scalp electrical potentials and current source densities of the qEEG. qEEG and qMRI T(2) were related by a frequency tuning with maxima in the alpha (8-12Hz) and the lower EEG frequencies (0.5-5Hz), which varied as a function of spatial location. The Laplacian of T(2) acted like a spatial-temporal "lens" by increasing the spatial-temporal resolution of correlation between 3-dimensional T(2) and the ear referenced alert but resting spontaneous qEEG. The severity of traumatic brain injury can be modeled by a linear transfer function that relates the molecular qMRI to qEEG resonant frequencies.

  3. Reducing Traumatic Brain Injuries in Youth Sports: Youth Sports Traumatic Brain Injury State Laws, January 2009–December 2012

    PubMed Central

    2013-01-01

    Objectives. I sought to describe current state-wide youth sports traumatic brain injury (TBI) laws and their relationship to prevailing scientific understandings of youth sports TBIs, and to facilitate further research by creating an open-source data set of current laws. Methods. I used Westlaw and LexisNexis databases to create a 50-state data set of youth sports TBI laws enacted between January 2009 and December 2012. I collected and coded the text and citations of each law and developed a protocol and codebook to facilitate future research. Results. Forty-four states and Washington, DC, passed youth sports TBI laws between 2009 and 2012. No state’s youth sports TBI law focuses on primary prevention. Instead, such laws focus on (1) increasing coaches’ and parents’ ability to identify and respond to TBIs and (2) reducing the immediate risk of multiple TBIs. Conclusions. Existing youth sports TBI laws were not designed to reduce initial TBIs. Evaluation is required to assess their effectiveness in reducing the risk and consequences of multiple TBIs. Continued research and evaluation of existing laws will be needed to develop a more comprehensive youth TBI-reduction solution. PMID:23678903

  4. Objective and Subjective Factors as Predictors of Post-Traumatic Stress Symptoms in Parents of Children with Cancer – A Longitudinal Study

    PubMed Central

    Lindahl Norberg, Annika; Pöder, Ulrika; Ljungman, Gustaf; von Essen, Louise

    2012-01-01

    Background Parents of children with cancer report post-traumatic stress symptoms (PTSS) years after the child's successful treatment is completed. The aim of the present study was to analyze a number of objective and subjective childhood cancer-related factors as predictors of parental PTSS. Methods Data were collected from 224 parents during and after their child's cancer treatment. Data sources include self-report questionnaires and medical records. Results In a multivariate hierarchical model death of the child, parent's perception of child psychological distress and total symptom burden predicted higher levels of PTSS. In addition, immigrants and unemployed parents reported higher levels of PTSS. The following factors did not predict PTSS: parent gender, family income, previous trauma, child's prognosis, treatment intensity, non-fatal relapse, and parent's satisfaction with the child's care. Conclusions Although medical complications can be temporarily stressful, a parent's perception of the child's distress is a more powerful predictor of parental PTSS. The vulnerability of unemployed parents and immigrants should be acknowledged. In addition, findings highlight that the death of a child is as traumatic as could be expected. PMID:22567141

  5. Reassessment of psychological distress and post-traumatic stress disorder in United States Air Force Distributed Common Ground System operators.

    PubMed

    Prince, Lillian; Chappelle, Wayne L; McDonald, Kent D; Goodman, Tanya; Cowper, Sara; Thompson, William

    2015-03-01

    The goal of this study was to assess for the main sources of occupational stress, as well as self-reported symptoms of distress and post-traumatic stress disorder among U.S. Air Force (USAF) Distributed Common Ground System (DCGS) intelligence exploitation and support personnel. DCGS intelligence operators (n=1091) and nonintelligence personnel (n = 447) assigned to a USAF Intelligence, Surveillance, and Reconnaissance Wing responded to the web-based survey. The overall survey response rate was 31%. Study results revealed the most problematic stressors among DCGS intelligence personnel included high workload, low manning, as well as organizational leadership and shift work issues. Results also revealed 14.35% of DCGS intelligence operators' self-reported high levels of psychological distress (twice the rate of DCGS nonintelligence support personnel). Furthermore, 2.0% to 2.5% self-reported high levels of post-traumatic stress disorder symptoms, with no significant difference between groups. The implications of these findings are discussed along with recommendations for USAF medical and mental health providers, as well as operational leadership. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  6. Development of an intravascular heating source using an MR imaging guidewire.

    PubMed

    Qiu, Bensheng; Yeung, Christopher J; Du, Xiangying; Atalar, Ergin; Yang, Xiaoming

    2002-12-01

    To develop a novel endovascular heating source using a magnetic resonance (MR) imaging guidewire (MRIG) to deliver controlled microwave energy into the target vessel for thermal enhancement of vascular gene transfection. A 0.032-inch MRIG was connected to a 2.45-GHz microwave generator. We 1) calculated the microwave power loss along the MRIG, 2) simulated the power distribution around the MRIG, 3) measured the temperature increase vs. input power with the MRIG, and 4) evaluated the thermal effect on the balloon-compressed/microwave-heated aorta of six living rabbits. In addition, during balloon inflation, we also simultaneously generated high-resolution MR images of the aortic wall. The power loss was calculated to be 3.9 dB along the MRIG. The simulation-predicted power distribution pattern was cylindrically symmetric, analogous to the geometry of vessels. Under balloon compression, the vessel wall could be locally heated at 41 degrees C with no thermal damage apparent on histology. This study demonstrates the possibility of using the MRIG as a multifunctional device, not only as a receiver antenna to generate intravascular high-resolution MR images of atherosclerotic plaques and as a conventional guidewire to guide endovascular interventions during MR imaging, but also as a potential intravascular heating source to produce local heat for thermal enhancement of vascular gene transfection. Copyright 2002 Wiley-Liss, Inc.

  7. A threatened beluga (Delphinapterus leucas) population in the traffic lane: vessel-generated noise characteristics of the Saguenay-St. Lawrence Marine Park, Canada.

    PubMed

    McQuinn, Ian H; Lesage, Véronique; Carrier, Dominic; Larrivée, Geneviève; Samson, Yves; Chartrand, Sylvain; Michaud, Robert; Theriault, James

    2011-12-01

    The threatened resident beluga population of the St. Lawrence Estuary shares the Saguenay-St. Lawrence Marine Park with significant anthropogenic noise sources, including marine commercial traffic and a well-established, vessel-based whale-watching industry. Frequency-dependent (FD) weighting was used to approximate beluga hearing sensitivity to determine how noise exposure varied in time and space at six sites of high beluga summer residency. The relative contribution of each source to acoustic habitat degradation was estimated by measuring noise levels throughout the summer and noise signatures of typical vessel classes with respect to traffic volume and sound propagation characteristics. Rigid-hulled inflatable boats were the dominant noise source with respect to estimated beluga hearing sensitivity in the studied habitats due to their high occurrence and proximity, high correlation with site-specific FD-weighted sound levels, and the dominance of mid-frequencies (0.3-23 kHz) in their noise signatures. Median C-weighted sound pressure level (SPL(RMS)) had a range of 19 dB re 1 μPa between the noisiest and quietest sites. Broadband SPL(RMS) exceeded 120 dB re 1 μPa 8-32% of the time depending on the site. Impacts of these noise levels on St. Lawrence beluga will depend on exposure recurrence and individual responsiveness. © 2011 Acoustical Society of America

  8. Seismic Observation of the 26 March 2010 Sinking of the South Korean Naval Vessel Cheonanham

    NASA Astrophysics Data System (ADS)

    Rhee, S.; Hong, T.

    2011-12-01

    A South Korean naval vessel, Cheonanham, sank at ~2.5 km southwest from Bakryeong Island (37.929°N, 124.601°E) in 21:22 local time (12:22 UTC) on 26 March 2010. Only 58 people out of the 104 crew members were rescued from the incident, and the other 46 sailors were dead or missing in the incident. Three plausible causes of the sinking were raised: (1) striking by an explosive source (torpedo or mine), (2) shear breakage due to strain accumulation by fatigue, and (3) collision with a sunken rock. The incident was recorded as an M1.5 event at local seismic stations. We analyze local seismic records and investigate the source properties. The event location is determined not only by a usual location method, but also using low-frequency horizontal polarization analysis. The determined event location agrees with the reported sinking location. The S-wave amplitudes are found to be comparable to the P-wave amplitudes. Seismic waves coupled from shock waves are observed, which allows us to constrain the epicentral distance and explosion-source feature. The coupled shock waves have a dominant frequency of ~32 Hz. The shock waves and high P/S amplitude ratios suggest an underwater explosion that is responsible for the vessel sinking. The spectral contents of P waves allows us to constrain the source depth in the water. We infer the depth of the explosion in the sea by comparing the observed spectra with synthetic spectra. We compare the seismic features with those from nuclear explosions.

  9. 40 CFR Table 8 to Subpart G of... - Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Wastewater Provisions for Process Units at New Sources 8 Table 8 to Subpart G of Part 63 Protection of... Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 8 Table 8 to Subpart G of Part 63—Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources Chemical name CAS No...

  10. 40 CFR Table 8 to Subpart G of... - Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Wastewater Provisions for Process Units at New Sources 8 Table 8 to Subpart G of Part 63 Protection of... Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 8 Table 8 to Subpart G of Part 63—Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources Chemical name CAS No...

  11. 40 CFR Table 8 to Subpart G of... - Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Wastewater Provisions for Process Units at New Sources 8 Table 8 to Subpart G of Part 63 Protection of... Vessels, Transfer Operations, and Wastewater Pt. 63, Subpt. G, Table 8 Table 8 to Subpart G of Part 63—Organic HAP's Subject to the Wastewater Provisions for Process Units at New Sources Chemical name CAS No...

  12. Arctic research vessel design would expand science prospects

    NASA Astrophysics Data System (ADS)

    Elsner, Robert; Kristensen, Dirk

    The U.S. polar marine science community has long declared the need for an arctic research vessel dedicated to advancing the study of northern ice-dominated seas. Planning for such a vessel began 2 decades ago, but competition for funding has prevented construction. A new design program is underway, and it shows promise of opening up exciting possibilities for new research initiatives in arctic marine science.With its latest design, the Arctic Research Vessel (ARV) has grown to a size and capability that will make it the first U.S. academic research vessel able to provide access to the Arctic Ocean. This ship would open a vast arena for new studies in the least known of the world's seas. These studies promise to rank high in national priority because of the importance of the Arctic Ocean as a source of data relating to global climate change. Other issues that demand attention in the Arctic include its contributions to the world's heat budget, the climate history buried in its sediments, pollution monitoring, and the influence of arctic conditions on marine renewable resources.

  13. Spread of thermal energy and heat sinks: implications for nerve-sparing robotic prostatectomy.

    PubMed

    Khan, Farhan; Rodriguez, Esequiel; Finley, David S; Skarecky, Douglas W; Ahlering, Thomas E

    2007-10-01

    During nerve-sparing robot-assisted laparoscopic prostatectomy, nerve injury caused by thermal energy is a concern. Using a porcine model, we studied thermal spread and queried whether vessels such as the prostatic pedicle may act as a heat sink, reducing the spread of thermal energy. Monopolar (MP) and bipolar (BP) cautery was applied laparoscopically on the anterior abdominal wall surface of six pigs with the da Vinci robot. Using fiberoptic thermometry (Luxtron Inc. Santa Clara, CA), temperatures were recorded with and without the interposed inferior epigastric vessels to evaluate the heat sink effect. Interposition of the inferior epigastric vessels definitively demonstrated a heat sink phenomenon: at 7 mm from the MP/BP energy source, temperatures rose 10.7 degrees C to 13.8 degrees C without interposed vessels versus only 1.9 degrees C to 2.5 degrees C when vessels were interposed (P < 0.001). The heat sink phenomenon suggests that the prostatic vascular pedicle should be protective of the neurovascular bundle during transection of the bladder neck during laparoscopic prostatectomy.

  14. 50 CFR 85.22 - Grant proposals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) FINANCIAL ASSISTANCE-WILDLIFE SPORT FISH RESTORATION PROGRAM CLEAN VESSEL ACT GRANT PROGRAM Application for..., education, sensitive waters, public access, and estimated costs; (e) Amount and source of matching funds...

  15. Identifying Anomalous Behaviour in AIS Data: Loitering and Gaps in Transmission as Indicators of IUU Associated Behaviour.

    NASA Astrophysics Data System (ADS)

    Ford, J.; Peel, D.; Wilcox, C.; Kroodsma, D.

    2016-12-01

    Identifying anomalous behaviour associated with Illegal, Unreported and Unregulated (IUU) fishing including supportive activities such as transshipment, is a key step to combating IUU fishing. We use spatial statistical models and Automatic Identification System (AIS) data to identify anomalous activity, specifically various indicators of loitering behaviours (for example, vessels travelling slower than expected, perhaps rendezvousing for transshipment), and gaps in AIS transmissions. Gaps occur for three basic reasons: saturation of the system in locations with high vessel density; poor quality transmissions due to equipment on the vessel or receiver; and intentional disabling of AIS transmitters. Resolving which of these mechanisms is generating gaps in transmissions from a given vessel is a critical task in using AIS to monitor vessels. Moreover, separating saturation and equipment issues from intentional disabling is a useful task in risk identification of IUU associated behaviour. Using this information on loitering behaviour and gaps in transmission, we identify and rank vessels which appear to be acting anomalously, with a focus on identifying potential IUU related activities. This information, combined with other sources of data, could help support enforcement agencies to implement international strategies such as the Port State Measures Agreement. A global list of such vessels and historical evidence of anomalous behaviour, would increase local powers of protection and provide one more step toward transparency within global fisheries.

  16. Spontaneous subserosal venous rupture overlying a uterine leiomyoma in a young woman.

    PubMed

    Jenayah, Amel Achour; Saoudi, Sarah; Sferi, Nour; Skander, Rim; Marzouk, Sofiène Ben; Cherni, Abdallah; Sfar, Ezzeddine; Chelli, Dalenda; Boudaya, Fethia

    2017-01-01

    Uterine leiomyomas are very common tumors found in women. Rupture of veins on the surface of uterine leiomyoma is an unusual source of hemoperitoneum. It is an extremely uncommon gynaecological cause of hemoperitoneum. It is a life threatening emergency. We report a case of massive intraperitoneal hemorrhage due to rupture of vessels on the surface of subserous leiomyoma. A differential diagnosis of rupture of leiomyoma'ssurface vessel should be considered, while dealing with a case of hemoperitoneum with pelvic mass.

  17. Dual-Anode Nickel/Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.; Ryan, Timothy P.

    1994-01-01

    Use of two hydrogen anodes in nickel/hydrogen cell reduces ohmic and concentration polarizations contributing to internal resistance, yielding cell with improved discharging performance compared to single-anode cell. Dual-anode concept incorporated into nickel/hydrogen cells of individual pressure-vessel type (for use aboard spacecraft) and common pressure-vessel type, for use on Earth to store electrical energy from photovoltaic sources, "uninterruptible" power supplies of computer and telephone systems, electric vehicles, and load leveling on power lines. Also applicable to silver/hydrogen and other metal/gas batteries.

  18. 46 CFR 183.322 - Multiple generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.322 Multiple generators. When a vessel is equipped with two or more generators to supply ship's service power, the following requirements...

  19. 46 CFR 183.322 - Multiple generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.322 Multiple generators. When a vessel is equipped with two or more generators to supply ship's service power, the following requirements...

  20. 46 CFR 183.322 - Multiple generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.322 Multiple generators. When a vessel is equipped with two or more generators to supply ship's service power, the following requirements...

Top