DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, N.
1995-05-02
This document provides the Functional Design Criteria (FDC) for Project C-018H, the 242-A Evaporator and Plutonium-Uranium Extraction (PUREX) Plant Condensate Treatment Facility (Also referred to as the 200 Area Effluent Treatment Facility [ETF]). The project will provide the facilities to treat and dispose of the 242-A Evaporator process condensate (PC), the Plutonium-Uranium Extraction (PUREX) Plant process condensate (PDD), and the PUREX Plant ammonia scrubber distillate (ASD).
Department of Energy Technology Readiness Assessments - Process Guide and Training Plan
2008-09-12
Hanford Waste Treatment and Immobilization Plant ( WTP ) Analytical Laboratory, Low Activity Waste (LAW) Facility and Balance of Facilities (3 TRAs... WTP High-Level Waste (HLW) Facility – WTP Pre-Treatment (PT) Facility – Hanford River Protection Project Low Activity Waste Treatment Alternatives
ERIC Educational Resources Information Center
Deal, Gerald A.; Montgomery, James A.
This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…
ERIC Educational Resources Information Center
Schwing, Carl M.
This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…
ERIC Educational Resources Information Center
Mason, George J.
This guide for developing standard operating job procedures for wastewater treatment facilities is devoted to the activated sludge aeration and sedimentation process. This process is for conversion of nonsettleable and nonfloatable materials in wastewater to settleable, floculated biological groups and separation of the settleable solids from the…
ERIC Educational Resources Information Center
Schwing, Carl M.
This guide describes standard operating job procedures for the digestion process of wastewater treatment facilities. This process is for reducing the volume of sludge to be treated in subsequent units and to reduce the volatile content of sludge. The guide gives step-by-step instructions for pre-startup, startup, continuous operating, shutdown,…
ERIC Educational Resources Information Center
Erdogan, Ibrahim
2006-01-01
In this extended biology, ecology, and earth science activity, students construct hands-on models of natural wastewater treatment and wastewater treatment facilities to achieve an understanding of wastewater treatment process in nature and wastewater treatment facilities. During this simulation activity, students have opportunities to learn…
ERIC Educational Resources Information Center
Schwing, Carl M.
This guide describes standard operating job procedures for the sludge conditioning and dewatering process of wastewater treatment facilities. In this process, sludge is treated with chemicals to make the sludge coagulate and give up its water more easily. The treated sludge is then dewatered using a vacuum filter. The guide gives step-by-step…
Yoon, Jeong-Ae; Park, Se-Gwan; Roh, Hyo-Lyun
2015-10-01
[Purpose] This study was conducted to compare the correlation between social interaction and activities of daily living (ADL) between community-dwelling and long-term care facility stroke patients. [Subjects and Methods] The Subjects were 65 chronic stroke patients (32 facility-residing, 33 community-dwelling). The Evaluation Social Interaction (ESI) tool was used to evaluate social interaction and the Assessment of Motor and Process Skills (AMPS) measure was used to evaluate ADL. [Results] Both social interaction and ADL were higher in community-dwelling than facility-residing stroke patients. There was a correlation between ESI and ADL for both motor and process skills among facility-residing patients, while only ADL process skills and ESI correlated among community-dwelling patients. In a partial correlation analysis using ADL motor and process skills as control variables, only process skills correlated with ESI. [Conclusion] For rehabilitation of stroke patients, an extended treatment process that combines ADL and social activities is likely to be required. Furthermore, treatment programs and institutional systems that can improve social interaction and promote health maintenance for community-dwelling and facility-residing chronic stroke patients are needed throughout the rehabilitation process.
In-Plant Reuse of Pollution Abated Waters.
1984-08-01
Carbon Treatment Facility Prefilters D-10 Spent Carbon Receiving Tank EZ D-11 Powdered Carbon Feeder System E. Process Chemical Assay/Monitoring...PBA manufacturing complex, several wastewater treatment facilities were built to treat wastewater from various plants . This task deals with...all of which discharge to the Central Treatment Facility (Appendix K-I). The plant is permitted (Appendix I-I) by EPA and consists of a lime/alum
Biogasification of Walt Disney World biomass waste blend. Annual report Jan-Dec 82
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Chynoweth, D.P.; Janulis, J.
1983-05-01
The objective of this research is to develop efficient processes for conversion of biomass-waste blends to methane and other resources. To evaluate the technical and economic feasibility, an experimental test facility (ETU) is being designed and installed at the Reedy Creek Wastewater Treatment Plant at Walt Disney World, Orlando, Florida. The facility will integrate a biomethanogenic conversion process with a waste-water treatment process employing water hyacinth ponds for secondary and tertiary treatment of sewage produced at Walt Disney World. The ETU will be capable of feeding 1-wet ton per day of water hyacinth-sludge blends to the digestion system for productionmore » of methane and other byproducts. The detailed design of the facility has been completed and procurement of equipment is in progress.« less
Responding to Harmful Algal Blooms: Treatment Optimization
This presentation discusses: (1) analytical methods for toxins and cyanobacteria within the context of monitoring a treatment process, (2) toxin and cell removal capacities for common drinking water treatment processes, (3) issues to consider when evaluating a treatment facility...
9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...
9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...
9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...
9 CFR 590.548 - Drying, blending, packaging, and heat treatment rooms and facilities.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Drying, blending, packaging, and heat..., blending, packaging, and heat treatment rooms and facilities. (a) General. Processing rooms shall be... vacuum cleaned daily. (c) The heat treatment room shall be of an approved construction and be maintained...
ERIC Educational Resources Information Center
Pavkov, Thomas W.; Lourie, Ira S.; Hug, Richard W.; Negash, Sesen
2010-01-01
This descriptive case study reports on the positive impact of a consultative review methodology used to conduct quality assurance reviews as part of the Residential Treatment Center Evaluation Project. The study details improvement in the quality of services provided to youth in unmonitored residential treatment facilities. Improvements were…
Process Control Manual for Aerobic Biological Wastewater Treatment Facilities.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This Environmental Protection Agency (EPA) publication is an operations manual for activated sludge and trickling filter wastewater treatment facilities. The stated purpose of the manual is to provide an on-the-job reference for operators of these two types of treatment plants. The overall objective of the manual is to aid the operator in…
Emissions model of waste treatment operations at the Idaho Chemical Processing Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schindler, R.E.
1995-03-01
An integrated model of the waste treatment systems at the Idaho Chemical Processing Plant (ICPP) was developed using a commercially-available process simulation software (ASPEN Plus) to calculate atmospheric emissions of hazardous chemicals for use in an application for an environmental permit to operate (PTO). The processes covered by the model are the Process Equipment Waste evaporator, High Level Liquid Waste evaporator, New Waste Calcining Facility and Liquid Effluent Treatment and Disposal facility. The processes are described along with the model and its assumptions. The model calculates emissions of NO{sub x}, CO, volatile acids, hazardous metals, and organic chemicals. Some calculatedmore » relative emissions are summarized and insights on building simulations are discussed.« less
Modelling the energy costs of the wastewater treatment process: The influence of the aging factor.
Castellet-Viciano, Lledó; Hernández-Chover, Vicent; Hernández-Sancho, Francesc
2018-06-01
Wastewater treatment plants (WWTPs) are aging and its effects on the process are more evident as time goes by. Due to the deterioration of the facilities, the efficiency of the treatment process decreases gradually. Within this framework, this paper proves the increase in the energy consumption of the WWTPs with time, and finds differences among facilities size. Accordingly, the paper aims to develop a dynamic energy cost function capable of predicting the energy cost of the process in the future. The time variable is used to introduce the aging effects on the energy cost estimation in order to increase the accuracy of the estimation. For this purpose, the evolution of energy costs will be assessed and modelled for a group of WWTPs using the methodology of cost functions. The results will be useful for the managers of the facilities in the decision making process. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorr, Kent A.; Freeman-Pollard, Jhivaun R.; Ostrom, Michael J.
CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy's (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility tomore » meet DOE's mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team's successful integration of the project's core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE's mission objective, as well as attainment of LEED GOLD certification (Figure 1), which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. (authors)« less
Treatment Study Plan for Nitrate Salt Waste Remediation Revision 1.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juarez, Catherine L.; Funk, David John; Vigil-Holterman, Luciana R.
2016-03-07
The two stabilization treatment methods that are to be examined for their effectiveness in the treatment of both the unremediated and remediated nitrate salt wastes include (1) the addition of zeolite and (2) cementation. Zeolite addition is proposed based on the results of several studies and analyses that specifically examined the effectiveness of this process for deactivating nitrate salts. Cementation is also being assessed because of its prevalence as an immobilization method used for similar wastes at numerous facilities around the DOE complex, including at Los Alamos. The results of this Treatment Study Plan will be used to provide themore » basis for a Resource Conservation and Recovery Act (RCRA) permit modification request of the LANL Hazardous Waste Facility Permit for approval by the New Mexico Environment Department-Hazardous Waste Bureau (NMED-HWB) of the proposed treatment process and the associated facilities.« less
76 FR 43489 - Deferral for CO2
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
.... 221320 Sewage treatment facilities. 562212 Solid waste landfills. Fermentation processes......... 325193... processors burning agricultural biomass residues, using fermentation processes, or producing/using biogas... treatment or manure management processes; CO 2 from fermentation during ethanol production or other...
Opportunities for Automated Demand Response in California Wastewater Treatment Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aghajanzadeh, Arian; Wray, Craig; McKane, Aimee
Previous research over a period of six years has identified wastewater treatment facilities as good candidates for demand response (DR), automated demand response (Auto-DR), and Energy Efficiency (EE) measures. This report summarizes that work, including the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy used and demand, as well as details of the wastewater treatment process. It also discusses control systems and automated demand response opportunities. Furthermore, this report summarizes the DR potential of three wastewater treatment facilities. In particular, Lawrence Berkeley National Laboratory (LBNL) has collected data at these facilities from control systems, submetered processmore » equipment, utility electricity demand records, and governmental weather stations. The collected data were then used to generate a summary of wastewater power demand, factors affecting that demand, and demand response capabilities. These case studies show that facilities that have implemented energy efficiency measures and that have centralized control systems are well suited to shed or shift electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. In summary, municipal wastewater treatment energy demand in California is large, and energy-intensive equipment offers significant potential for automated demand response. In particular, large load reductions were achieved by targeting effluent pumps and centrifuges. One of the limiting factors to implementing demand response is the reaction of effluent turbidity to reduced aeration at an earlier stage of the process. Another limiting factor is that cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities, limit a facility’s potential to participate in other DR activities.« less
Luiz, Marguti André; Sidney Seckler, Ferreira Filho; Passos, Piveli Roque
2018-06-01
An emerging practice for water treatment plant (WTP) sludge is its disposal in wastewater treatment plants (WWTP), an alternative that does not require the installation of sludge treatment facilities in the WTP. This practice can cause both positive and negative impacts in the WWTP processes since the WTP sludge does not have the same characteristics as domestic wastewater. This issue gives plenty of information in laboratory and pilot scales, but lacks data from full-scale studies. The main purpose of this paper is to study the impact of disposing sludge from the Rio Grande conventional WTP into the ABC WWTP, an activated sludge process facility. Both plants are located in São Paulo, Brazil, and are full-scale facilities. The WTP volumetric flow rate (4.5 m³/s) is almost three times that of WWTP (1.6 m³/s). The data used in this study came from monitoring the processes at both plants. The WWTP liquid phase treatment analysis included the variables BOD, COD, TSS, VSS, ammonia, total nitrogen, phosphorus and iron, measured at the inlet, primary effluent, mixed liquor, and effluent. For the WWTP solids treatment, the parameters tested were total and volatile solids. The performance of the WWTP process was analyzed with and without sludge addition: 'without sludge' in years 2005 and 2006 and 'with sludge' from January 2007 to March 2008. During the second period, the WTP sludge addition increased the WWTP removal efficiencies for solids (93%-96%), organic matter (92%-94% for BOD) and phosphorus (52%-88%), when compared to the period 'without sludge'. These improvements can be explained by higher feed concentrations combined to same or lower effluent concentrations in the 'with sludge' period. No critical negative impacts occurred in the sludge treatment facilities, since the treatment units absorbed the extra solids load from the WTP sludge. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LUECK, K.J.
2004-10-18
This report documents an engineering study conducted to evaluate alternatives for treating secondary waste in the secondary treatment train (STT) of the Hanford Site 200 Area Effluent Treatment Facility (ETF). The study evaluates ETF STT treatment alternatives and recommends preferred alternatives for meeting the projected future missions of the ETF. The preferred alternative(s) will process projected future ETF influents to produce a solid waste acceptable for final disposal on the Hanford Site. The main text of this report summarizes the ETF past and projected operations, lists the assumptions about projected operations that provide the basis for the engineering evaluation, andmore » summarizes the evaluation process. The evaluation process includes identification of available modifications to the current ETF process, screens those modifications for technical viability, evaluates the technically viable alternatives, and provides conclusions and recommendations based on that evaluation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorr, Kent A.; Ostrom, Michael J.; Freeman-Pollard, Jhivaun R.
CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy’s (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built to an accelerated schedule with American Recovery and Reinvestment Act (ARRA) funds. There were many contractual, technical, configuration management, quality, safety, and Leadership in Energy and Environmental Design (LEED) challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility tomore » meet DOE’s mission objective of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012. The project team’s successful integration of the project’s core values and green energy technology throughout design, procurement, construction, and start-up of this complex, first-of-its-kind Bio Process facility resulted in successful achievement of DOE’s mission objective, as well as attainment of LEED GOLD certification, which makes this Bio Process facility the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award.« less
This document corrects typographical errors in the regulatory text of the final standards that would limit organic air emissions as a class at hazardous waste treatment, storage, and disposal facilities (TSDF) that are subject to regulation under subtitle
Suzuki, Kazumichi; Gillin, Michael T; Sahoo, Narayan; Zhu, X Ronald; Lee, Andrew K; Lippy, Denise
2011-07-01
To evaluate patient census, equipment clinical availability, maximum daily treatment capacity, use factor for major beam delivery parameters, and treatment process time for actual treatments delivered by proton therapy systems. The authors have been recording all beam delivery parameters, including delivered dose, energy, range, spread-out Bragg peak widths, gantry angles, and couch angles for every treatment field in an electronic medical record system. We analyzed delivery system downtimes that had been recorded for every equipment failure and associated incidents. These data were used to evaluate the use factor of beam delivery parameters, the size of the patient census, and the equipment clinical availability of the facility. The duration of each treatment session from patient walk-in and to patient walk-out of the treatment room was measured for 82 patients with cancers at various sites. The yearly average equipment clinical availability in the last 3 yrs (June 2007-August 2010) was 97%, which exceeded the target of 95%. Approximately 2200 patients had been treated as of August 2010. The major disease sites were genitourinary (49%), thoracic (25%), central nervous system (22%), and gastrointestinal (2%). Beams have been delivered in approximately 8300 treatment fields. The use factor for six beam delivery parameters was also evaluated. Analysis of the treatment process times indicated that approximately 80% of this time was spent for patient and equipment setup. The other 20% was spent waiting for beam delivery and beam on. The total treatment process time can be expressed by a quadratic polynomial of the number of fields per session. The maximum daily treatment capacity of our facility using the current treatment processes was estimated to be 133 +/- 35 patients. This analysis shows that the facility has operated at a high performance level and has treated a large number of patients with a variety of diseases. The use factor of beam delivery parameters varies by disease site. Further improvements in efficiency may be realized in the equipment- and patient-related processes of treatment.
Distributed architecture and distributed processing mode in urban sewage treatment
NASA Astrophysics Data System (ADS)
Zhou, Ruipeng; Yang, Yuanming
2017-05-01
Decentralized rural sewage treatment facility over the broad area, a larger operation and management difficult, based on the analysis of rural sewage treatment model based on the response to these challenges, we describe the principle, structure and function in networking technology and network communications technology as the core of distributed remote monitoring system, through the application of case analysis to explore remote monitoring system features in a decentralized rural sewage treatment facilities in the daily operation and management. Practice shows that the remote monitoring system to provide technical support for the long-term operation and effective supervision of the facilities, and reduced operating, maintenance and supervision costs for development.
40 CFR 240.200-2 - Recommended procedures: Design.
Code of Federal Regulations, 2014 CFR
2014-07-01
... processing. These include: Certain bulky wastes (e.g., combustible demolition and construction debris, tree... treatment facilities, raw sewage sludges, and septic tank pumpings. (b) If the facility is designed to...
40 CFR 240.200-2 - Recommended procedures: Design.
Code of Federal Regulations, 2012 CFR
2012-07-01
... processing. These include: Certain bulky wastes (e.g., combustible demolition and construction debris, tree... treatment facilities, raw sewage sludges, and septic tank pumpings. (b) If the facility is designed to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lekov, Alex; Thompson, Lisa; McKane, Aimee
This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and thatmore » facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.« less
Energy Efficiency Strategies for Municipal Wastewater Treatment Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daw, J.; Hallett, K.; DeWolfe, J.
2012-01-01
Water and wastewater systems are significant energy consumers with an estimated 3%-4% of total U.S. electricity consumption used for the movement and treatment of water and wastewater. Water-energy issues are of growing importance in the context of water shortages, higher energy and material costs, and a changing climate. In this economic environment, it is in the best interest for utilities to find efficiencies, both in water and energy use. Performing energy audits at water and wastewater treatment facilities is one way community energy managers can identify opportunities to save money, energy, and water. In this paper the importance of energymore » use in wastewater facilities is illustrated by a case study of a process energy audit performed for Crested Butte, Colorado's wastewater treatment plant. The energy audit identified opportunities for significant energy savings by looking at power intensive unit processes such as influent pumping, aeration, ultraviolet disinfection, and solids handling. This case study presents best practices that can be readily adopted by facility managers in their pursuit of energy and financial savings in water and wastewater treatment. This paper is intended to improve community energy managers understanding of the role that the water and wastewater sector plays in a community's total energy consumption. The energy efficiency strategies described provide information on energy savings opportunities, which can be used as a basis for discussing energy management goals with water and wastewater treatment facility managers.« less
40 CFR 436.21 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... However, if a mine is also used for treatment of process generated waste water, discharges of commingled water from the facilities shall be deemed discharges of process generated waste water. (c) The term “10... treatment of such waste water. ...
Gaps in the Substance Use Disorder Treatment Referral Process: Provider Perceptions.
Blevins, Claire E; Rawat, Nishi; Stein, Michael D
2018-05-07
The demand for substance use disorder treatment is increasing, fueled by the opioid epidemic and the Affordable Care Act mandate to treat substance use disorders. The increased demand for treatment, however, is not being met by a corresponding increase in access to or availability of treatment. This report focuses specifically on the treatment referral process, which we have identified as 1 of the key barriers to timely and effective treatment. Difficulties in referral to substance use disorder treatment are examined through the lens of providers who make referrals (ie, referral source) and individuals who work in substance use disorder facilities (ie, referral recipient). Administrative officials, emergency department physicians, addiction physicians, government officials, providers, insurance officials, and mental health advocates (n = 59) were interviewed on the referral process protocol, challenges for providers and others making referrals, and issues with substance use treatment facility intake procedures. Several main themes were identified as barriers in the process: difficulties in determining patient eligibility, lack of transparency regarding treatment capacity, referral source knowledge/understanding of options, and issues with communication between referral source and recipient. We then proposed several solutions to address specific barriers. Current gaps in the referral process cause delays to care. Improving systems would involve addressing these themes and expanding the use of appropriate treatments for the many patients in need.
First Dutch Consensus of Pain Quality Indicators for Pain Treatment Facilities.
de Meij, Nelleke; van Grotel, Marloes; Patijn, Jacob; van der Weijden, Trudy; van Kleef, Maarten
2016-01-01
There is a general consensus about the need to define and improve the quality of pain treatment facilities. Although guidelines and recommendations to improve the quality of pain practice management have been launched, provision of appropriate pain treatment is inconsistent and the quality of facilities varies widely. The aim of the study was to develop an expert-agreed list of quality indicators applicable to pain treatment facilities. The list was also intended to be used as the basis for a set of criteria for registered status of pain treatment facilities. The University Pain Center Maastricht at the Department of Anesthesiology and Pain Management of the Maastricht University Medical Center conducted a 3-round Delphi study in collaboration with the Board of the Pain Section of the Dutch Society of Anesthesiologists (NVA). Twenty-five quality indicators were selected as relevant to 2 types of pain treatment facilities, pain clinics and pain centers. The final expert-agreed list consisted of 22 quality indicators covering 7 quality domains: supervision, availability of care, staffing level and patient load, quality policy, multidisciplinarity, regionalization, and research and education. This set of quality indicators may facilitate organizational evaluation and improve insight into service quality from the perspectives of patients, pain specialists, and other healthcare professionals. Recommendations for improvements to the current set of quality indicators are made. In 2014 the process of registering pain treatment facilities in the Netherlands started; facilities can register as a pain clinic or pain center. © 2015 World Institute of Pain.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conroy, Kevin W.; Vandergaast, Gerald
2012-07-01
The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated intomore » the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
Application is being made for a permit pursuant to Chapter 173--216 of the Washington Administrative Code (WAC), to discharge treated waste water and cooling tower blowdown from the 200 Area Effluent Treatment Facility (ETF) to land at the State-Approved Land Disposal Site (SALDS). The ETF is located in the 200 East Area and the SALDS is located north of the 200 West Area. The ETF is an industrial waste water treatment plant that will initially receive waste water from the following two sources, both located in the 200 Area on the Hanford Site: (1) the Liquid Effluent Retention Facility (LERF)more » and (2) the 242-A Evaporator. The waste water discharged from these two facilities is process condensate (PC), a by-product of the concentration of waste from DSTs that is performed in the 242-A Evaporator. Because the ETF is designed as a flexible treatment system, other aqueous waste streams generated at the Hanford Site may be considered for treatment at the ETF. The origin of the waste currently contained in the DSTs is explained in Section 2.0. An overview of the concentration of these waste in the 242-A Evaporator is provided in Section 3.0. Section 4.0 describes the LERF, a storage facility for process condensate. Attachment A responds to Section B of the permit application and provides an overview of the processes that generated the wastes, storage of the wastes in double-shell tanks (DST), preliminary treatment in the 242-A Evaporator, and storage at the LERF. Attachment B addresses waste water treatment at the ETF (under construction) and the addition of cooling tower blowdown to the treated waste water prior to disposal at SALDS. Attachment C describes treated waste water disposal at the proposed SALDS.« less
Gingerich, Daniel B; Mauter, Meagan S
2018-02-06
Conventional processes for municipal wastewater treatment facilities are energy and materially intensive. This work quantifies the air emission implications of energy consumption, chemical use, and direct pollutant release at municipal wastewater treatment facilities across the U.S. and assesses the potential to avoid these damages by generating electricity and heat from the combustion of biogas produced during anaerobic sludge digestion. We find that embedded and on-site air emissions from municipal wastewater treatment imposed human health, environmental, and climate (HEC) damages on the order of $1.63 billion USD in 2012, with 85% of these damages attributed to the estimated consumption of 19 500 GWh of electricity by treatment processes annually, or 0.53% of the US electricity demand. An additional 11.8 million tons of biogenic CO 2 are directly emitted by wastewater treatment and sludge digestion processes currently installed at plants. Retrofitting existing wastewater treatment facilities with anaerobic sludge digestion for biogas production and biogas-fueled heat and electricity generation has the potential to reduce HEC damages by up to 24.9% relative to baseline emissions. Retrofitting only large plants (>5 MGD), where biogas generation is more likely to be economically viable, would generate HEC benefits of $254 annually. These findings reinforce the importance of accounting for use-phase embedded air emissions and spatially resolved marginal damage estimates when designing sustainable infrastructure systems.
2012-10-01
facilities, such as water supply, waste water treatment , and power generation. The Ministry of Defense’s procurement process is unable to provide the...the Joint Regional Afghanistan Security Forces Compound Water Treatment System...Ministry of Interior NTM-A North Atlantic Treaty Organization Training Mission-Afghanistan O&M operation and maintenance PCO Primary Contracting Officer
ERIC Educational Resources Information Center
Petrasek, Al, Jr.
This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…
Water treatment capacity of forward osmosis systems utilizing power plant waste heat
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Xingshi; Gingerich, Daniel B.; Mauter, Meagan S.
Forward osmosis (FO) has the potential to improve the energy efficiency of membrane-based water treatment by leveraging waste heat from steam electric power generation as the primary driving force for separation. In this study, we develop a comprehensive FO process model, consisting of membrane separation, heat recovery, and draw solute regeneration (DSR) models. We quantitatively characterize three alternative processes for DSR: distillation, steam stripping, and air stripping. We then construct a mathematical model of the distillation process for DSR that incorporates hydrodynamics, mass and heat transport resistances, and reaction kinetics, and we integrate this into a model for the fullmore » FO process. Finally, we utilize this FO process model to derive a first-order approximation of the water production capacity given the rejected heat quantity and quality available at U.S. electric power facilities. We find that the upper bound of FO water treatment capacity using low-grade heat sources at electric power facilities exceeds process water treatment demand for boiler water make-up and flue gas desulfurization wastewater systems.« less
Water treatment capacity of forward osmosis systems utilizing power plant waste heat
Zhou, Xingshi; Gingerich, Daniel B.; Mauter, Meagan S.
2015-06-11
Forward osmosis (FO) has the potential to improve the energy efficiency of membrane-based water treatment by leveraging waste heat from steam electric power generation as the primary driving force for separation. In this study, we develop a comprehensive FO process model, consisting of membrane separation, heat recovery, and draw solute regeneration (DSR) models. We quantitatively characterize three alternative processes for DSR: distillation, steam stripping, and air stripping. We then construct a mathematical model of the distillation process for DSR that incorporates hydrodynamics, mass and heat transport resistances, and reaction kinetics, and we integrate this into a model for the fullmore » FO process. Finally, we utilize this FO process model to derive a first-order approximation of the water production capacity given the rejected heat quantity and quality available at U.S. electric power facilities. We find that the upper bound of FO water treatment capacity using low-grade heat sources at electric power facilities exceeds process water treatment demand for boiler water make-up and flue gas desulfurization wastewater systems.« less
Technology Readiness Assessment of Department of Energy Waste Processing Facilities
2007-09-11
Must Be Reliable, Robust, Flexible, and Durable 6 EM Is Piloting the TRA/AD2 Process Hanford Waste Treatment Plant ( WTP ) – The Initial Pilot Project...Evaluation WTP can only treat ~ ½ of the LAW in the time it will take to treat all the HLW. • There is a need for tank space that will get more urgent with...Facility before the WTP Pretreatment and High-Level Waste (HLW) Vitrification Facilities are available (Requires tank farm pretreatment capability) TRAs
Critical Protection Item classification for a waste processing facility at Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ades, M.J.; Garrett, R.J.
1993-10-01
This paper describes the methodology for Critical Protection Item (CPI) classification and its application to the Structures, Systems and Components (SSC) of a waste processing facility at the Savannah River Site (SRS). The WSRC methodology for CPI classification includes the evaluation of the radiological and non-radiological consequences resulting from postulated accidents at the waste processing facility and comparison of these consequences with allowable limits. The types of accidents considered include explosions and fire in the facility and postulated accidents due to natural phenomena, including earthquakes, tornadoes, and high velocity straight winds. The radiological analysis results indicate that CPIs are notmore » required at the waste processing facility to mitigate the consequences of radiological release. The non-radiological analysis, however, shows that the Waste Storage Tank (WST) and the dike spill containment structures around the formic acid tanks in the cold chemical feed area and waste treatment area of the facility should be identified as CPIs. Accident mitigation options are provided and discussed.« less
42 CFR 413.186 - Payment exception: Self-dialysis training costs in pediatric facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... NURSING FACILITIES Payment for End-Stage Renal Disease (ESRD) Services and Organ Procurement Costs § 413... completed, being retrained, or in the process of being trained). (7) The total treatments from the patient...
Code of Federal Regulations, 2011 CFR
2011-07-01
... treatment of domestic sewage in a treatment works. (i) Drinking water treatment sludge. This part does not... DISPOSAL OF SEWAGE SLUDGE General Provisions § 503.6 Exclusions. (a) Treatment processes. This part does... requirements for the use or disposal of sludge generated at an industrial facility during the treatment of...
ERIC Educational Resources Information Center
Charles County Community Coll., La Plata, MD.
This guide describes standard operating job procedures for the primary sedimentation process of wastewater treatment plants. The primary sedimentation process involves removing settleable and suspended solids, in part, from wastewater by gravitational forces, and scum and other floatable solids from wastewater by mechanical means. Step-by-step…
Orientation to Municipal Wastewater Treatment. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
Introductory-level material on municipal wastewater treatment facilities and processes is presented. Course topics include sources and characteristics of municipal wastewaters; objectives of wastewater treatment; design, operation, and maintenance factors; performance testing; plant staffing; and laboratory considerations. Chapter topics include…
Westinghouse Cementation Facility of Solid Waste Treatment System - 13503
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Torsten; Aign, Joerg
2013-07-01
During NPP operation, several waste streams are generated, caused by different technical and physical processes. Besides others, liquid waste represents one of the major types of waste. Depending on national regulation for storage and disposal of radioactive waste, solidification can be one specific requirement. To accommodate the global request for waste treatment systems Westinghouse developed several specific treatment processes for the different types of waste. In the period of 2006 to 2008 Westinghouse awarded several contracts for the design and delivery of waste treatment systems related to the latest CPR-1000 nuclear power plants. One of these contracts contains the deliverymore » of four Cementation Facilities for waste treatment, s.c. 'Follow on Cementations' dedicated to three locations, HongYanHe, NingDe and YangJiang, of new CPR-1000 nuclear power stations in the People's Republic of China. Previously, Westinghouse delivered a similar cementation facility to the CPR-1000 plant LingAo II, in Daya Bay, PR China. This plant already passed the hot functioning tests successfully in June 2012 and is now ready and released for regular operation. The 'Follow on plants' are designed to package three 'typical' kind of radioactive waste: evaporator concentrates, spent resins and filter cartridges. The purpose of this paper is to provide an overview on the Westinghouse experience to design and execution of cementation facilities. (authors)« less
NASA Astrophysics Data System (ADS)
Warner, N. R.; Menio, E. C.; Landis, J. D.; Vengosh, A.; Lauer, N.; Harkness, J.; Kondash, A.
2014-12-01
Recent public interest in high volume slickwater hydraulic fracturing (HVHF) has drawn increased interest in wastewater management practices by the public, researchers, industry, and regulators. The management of wastes, including both fluids and solids, poses many engineering challenges, including elevated total dissolved solids and elevated activities of naturally occurring radioactive materials (NORM). One management option for wastewater in particular, which is used in western Pennsylvania, USA, is treatment at centralized waste treatment facilities [1]. Previous studies conducted from 2010-2012 indicated that one centralized facility, the Josephine Brine Treatment facility, removed the majority of radium from produced water and hydraulic fracturing flowback fluid (HFFF) during treatment, but low activities of radium remained in treated effluent and were discharged to surface water [2]. Despite the treatment process and radium reduction, high activities (200 times higher than upstream/background) accumulated in stream sediments at the point of effluent discharge. Here we present new results from sampling conducted at two additional centralized waste treatment facilities (Franklin Brine Treatment and Hart Brine Treatment facilities) and Josephine Brine Treatment facility conducted in June 2014. Preliminary results indicate radium is released to surface water at very low (<50 pCi/L) to non-detectable activities, however; radium continues to accumulate in sediments surrounding the area of effluent release. Combined, the data indicate that 1) radium continues to be released to surface water streams in western Pennsylvania despite oil and gas operators voluntary ban on treatment and disposal of HFFF in centralized waste treatment facilities, 2) radium accumulation in sediments occurred at multiple brine treatment facilities and is not isolated to a single accidental release of contaminants or a single facility. [1] Wilson, J. M. and J. M. VanBriesen (2012). "Oil and Gas Produced Water Management and Surface Drinking Water Sources in Pennsylvania." Environmental Practice 14(04): 288-300. [2] Warner, N. R., C. A. Christie, R. B. Jackson and A. Vengosh (2013). "Impacts of Shale Gas Wastewater Disposal on Water Quality in Western Pennsylvania." ES&T 47(20): 11849-11857.
N-nitrosodimethylamine (NDMA) removal by reverse osmosis and UV treatment and analysis via LC-MS/MS.
Plumlee, Megan H; López-Mesas, Montserrat; Heidlberger, Andy; Ishida, Kenneth P; Reinhard, Martin
2008-01-01
N-nitrosodimethylamine (NDMA) is a probable human carcinogen found in ng/l concentrations in chlorinated and chloraminated water. A method was developed for the determination of ng/l levels of NDMA using liquid chromatography-tandem mass spectrometry (LC-MS/MS) preceded by sample concentration via solid-phase extraction with activated charcoal. Recoveries were greater than 90% and allowed a method reporting limit as low as 2ng/l. Using this method, the removal of NDMA was determined for the Interim Water Purification Facility (IWPF), an advanced wastewater treatment facility operated by the Orange County Water District (OCWD) in Southern California. The facility treats effluent from an activated sludge treatment plant with microfiltration (MF), reverse osmosis (RO), and an ultraviolet-hydrogen peroxide advanced oxidation process (UV-AOP). Six nitrosamines were surveyed: NDMA, N-nitrosomethylethylamine (NMEA), N-nitrosodiethylamine (NDEA), N-nitrosodi-n-propylamine (NDPA), N-nitrosopiperidine (NPip), and N-nitrosopyrrolidine (NPyr). Only NDMA was detected and at all treatment steps in the IWPF, with influent concentrations ranging from 20 to 59 ng/l. Removals for RO and UV ranged from 24% to 56% and 43% to 66%, respectively. Overall, 69+/-7% of the original NDMA concentration was removed from the product water across the advanced treatment process and, in combination with blending, the final concentration did not exceed the California drinking water notification level of 10 ng/l. NDMA removal data are consistent with findings reviewed for other advanced treatment facilities and laboratory studies.
Guidance for Preparing a Facility Plan. Revised Edition.
ERIC Educational Resources Information Center
Environmental Protection Agency, Washington, DC. Office of Water Programs.
This document provides information to assist with preparing a preliminary facility plan for construction of municipal sewage treatment works. The text describes the requirements in the applicable laws and regulations and suggests a planning process by which they can be met. (CS)
ERIC Educational Resources Information Center
Deal, Gerald A.; Montgomery, James A.
This guide describes standard operating job procedures for the grit removal process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up, continuous operation, and shut-down procedures. A description of the equipment used in the process is given. Some theoretical material is presented. (BB)
ERIC Educational Resources Information Center
Petrasek, Al, Jr.
This guide describes the standard operating job procedures for the tertiary multimedia filtration process of wastewater treatment plants. The major objective of the filtration process is the removal of suspended solids from the reclaimed wastewater. The guide gives step-by-step instructions for pre-start up, start-up, continuous operation, and…
Power Up with Methane Gas: Struthers Water Pollution Control Facility
The city of Struthers received $5.4 million in ARRA funding from the Ohio’s CWSRF for a project that uses methane gas produced at the Struthers Water Pollution Control Facility to power unit treatment processes and offset the facility’s energy footprint.
Müller-Schwefe, G H H; Nadstawek, J; Tölle, T; Nilges, P; Überall, M A; Laubenthal, H J; Bock, F; Arnold, B; Casser, H R; Cegla, T H; Emrich, O M D; Graf-Baumann, T; Henning, J; Horlemann, J; Kayser, H; Kletzko, H; Koppert, W; Längler, K H; Locher, H; Ludwig, J; Maurer, S; Pfingsten, M; Schäfer, M; Schenk, M; Willweber-Strumpf, A
2016-06-01
On behalf of the Medical/Psychological Pain Associations, Pain Patients Alliance and the Professional Association of Pain Physicians and Psychologists, the Joint Commission of Professional Societies and Organizations for Quality in Pain Medicine, working in close collaboration with the respective presidents, has developed verifiable structural and process-related criteria for the classification of medical and psychological pain treatment facilities in Germany. Based on the established system of graded care in Germany and on existing qualifications, these criteria also argue for the introduction of a basic qualification in pain medicine. In addition to the first-ever comprehensive description of psychological pain facilities, the criteria presented can be used to classify five different levels of pain facilities, from basic pain management facilities, to specialized institutions, to the Centre for Interdisciplinary Pain Medicine. The recommendations offer binding and verifiable criteria for quality assurance in pain medicine and improved pain treatment.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... Treatment Manual, and we did not retain text explaining that irradiation can be used as a substitute for... irradiation treatment, respectively. Where these sections have referred to facilities capable of performing...)(1) stated that irradiation treatment in accordance with part 305 could be substituted for other...
40 CFR 436.41 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... seepage. However, if a mine is also used for the treatment of process generated waste water, discharges of commingled water from the mine shall be deemed discharges of process generated waste water. (c) The term “10... water in a pit, pond, lagoon, mine or other facility used for treatment of such waste water. The terms...
Harris, Alex H S; Humphreys, Keith; Finney, John W
2007-12-01
Self-administered Addiction Severity Index (ASI) data were collected on 5,723 patients who received substance abuse treatment in 1 of 110 programs located at 73 Veterans Affairs facilities. The associations between each of three Washington Circle (WC) performance indicator scores (identification, initiation, and engagement) and their casemix-adjusted facility-level improvement in ASI drug and alcohol composites 7 months after intake were estimated. Higher initiation rates were not associated with facility-level improvement in ASI alcohol composite scores but were modestly associated with greater improvements in ASI drug composite scores. Identification and engagement rates were unrelated to 7-month outcomes. WC indicators focused on the early stages of treatment may tap necessary but insufficient processes for patients with substance use disorder to achieve good posttreatment outcomes. Ideally, the WC indicators would be supplemented with other measures of treatment quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C.; Burket, P.; Cozzi, A.
2014-08-01
The U.S. Department of Energy’s Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford’s tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in themore » time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. In addition, the WTP LAW vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as 137Cs, 129I, 99Tc, Cl, F, and SO4 that volatilize at the vitrification temperature of 1150°C in the absence of a continuous cold cap (that could minimize volatilization). The current waste disposal path for the WTP-SW is to process it through the Effluent Treatment Facility (ETF). Fluidized Bed Steam Reforming (FBSR) is being considered for immobilization of the ETF concentrate that would be generated by processing the WTP-SW. The focus of this current report is the WTP-SW.« less
Anderson, Erik; Addy, Min; Chen, Paul; Ruan, Roger
2018-02-01
A novel process was developed for the biorefining of floatable wastewater scum and other waste oils from water treatment facilities into biodiesel and other value-added bio-products. To test the scalability and commercial potential of the technology, a 7000 l/year pilot-scale system was designed and built. Scum from a wastewater treatment facility, located in St. Paul, Mn, was collected and converted into methyl esters (biodiesel) according to the process chemistry. All of the incoming and outgoing process streams were sampled, tested, weighed and recorded to calculate both the process efficiency and product quality. Data from the pilot-scale system operation was compared to laboratory results and the theoretically expected values for each individual unit operation. The biodiesel was tested using a third party laboratory and confirmed it met all of the US EPA's test requirements for commercial-grade biodiesel. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Perley, Gordon F.
This is a guide for standard operating job procedures for the pump station process of wastewater treatment plants. Step-by-step instructions are given for pre-start up inspection, start-up procedures, continuous routine operation procedures, and shut-down procedures. A general description of the equipment used in the process is given. Two…
National Biomedical Tracer Facility: Project definition study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heaton, R.; Peterson, E.; Smith, P.
The Los Alamos National Laboratory is an ideal institution and New Mexico is an ideal location for siting the National Biomedical Tracer Facility (NBTF). The essence of the Los Alamos proposal is the development of two complementary irradiation facilities that combined with our existing radiochemical processing hot cell facilities and waste handling and disposal facilities provide a low cost alternative to other proposals that seek to satisfy the objectives of the NBTF. We propose the construction of a 30 MeV cyclotron facility at the site of the radiochemical facilities, and the construction of a 100 MeV target station at LAMPFmore » to satisfy the requirements and objectives of the NBTF. We do not require any modifications to our existing radiochemical processing hot cell facilities or our waste treatment and disposal facilities to accomplish the objectives of the NBTF. The total capital cost for the facility defined by the project definition study is $15.2 M. This cost estimate includes $9.9 M for the cyclotron and associated facility, $2.0 M for the 100 MeV target station at LAMPF, and $3.3 M for design.« less
Escherichia coli, total coliform, and fecal coliform data were collected from two wastewater treatment facilities, a subsurface constructed wetlands, and the receiving stream. Results are presented from individual wastewater treatment process streams, final effluent and river sit...
What Medical Directors Need to Know about Dialysis Facility Water Management.
Kasparek, Ted; Rodriguez, Oscar E
2015-06-05
The medical directors of dialysis facilities have many operational clinic responsibilities, which on first glance, may seem outside the realm of excellence in patient care. However, a smoothly running clinic is integral to positive patient outcomes. Of the conditions for coverage outlined by the Centers for Medicare and Medicaid Services, one most critical to quality dialysis treatment is the provision of safe purified dialysis water, because there are many published instances where clinic failure in this regard has resulted in patient harm. As the clinical leader of the facility, the medical director is obliged to have knowledge of his/her facility's water treatment system to reliably ensure that the purified water used in dialysis will meet the standards for quality set by the Association for the Advancement of Medical Instrumentation and used by the Centers for Medicare and Medicaid Services for conditions for coverage. The methods used to both achieve and maintain these quality standards should be a part of quality assessment and performance improvement program meetings. The steps for water treatment, which include pretreatment, purification, and distribution, are largely the same, regardless of the system used. Each water treatment system component has a specific role in the process and requires individualized maintenance and monitoring. The medical director should provide leadership by being engaged with the process, knowing the facility's source water, and understanding water treatment system operation as well as the clinical significance of system failure. Successful provision of quality water will be achieved by those medical directors who learn, know, and embrace the requirements of dialysis water purification and system maintenance. Copyright © 2015 by the American Society of Nephrology.
Noyola, A; Paredes, M G; Güereca, L P; Molina, L T; Zavala, M
2018-10-15
Wastewater treatment (WWT) may be an important source of methane (CH 4 ), a greenhouse gas with significant global warming potential. Sources of CH 4 emissions from WWT facilities can be found in the water and in the sludge process lines. Among the methodologies for estimating CH 4 emissions inventories from WWT, the more adopted are the guidelines of the Intergovernmental Panel on Climate Change (IPCC), which recommends default emission factors (Tier 1) depending on WWT systems. Recent published results show that well managed treatment facilities may emit CH 4 , due to dissolved CH 4 in the influent wastewater; in addition, biological nutrient removal also will produce this gas in the anaerobic (or anoxic) steps. However, none of these elements is considered in the current IPCC guidelines. The aim of this work is to propose modified (and new) methane correction factors (MCF) regarding the current Tier 1 IPCC guidelines for CH 4 emissions from aerobic treatment systems, with and without anaerobic sludge digesters, focusing on intertropical countries. The modifications are supported on in situ assessment of fugitive CH 4 emissions in two facilities in Mexico and on relevant literature data. In the case of well-managed centralized aerobic treatment plant, a MCF of 0.06 (instead of the current 0.0) is proposed, considering that the assumption of a CH 4 -neutral treatment facility, as established in the IPCC methodology, is not supported. Similarly, a MCF of 0.08 is proposed for biological nutrient removal processes, being a new entry in the guidelines. Finally, a one-step straightforward calculation is proposed for centralized aerobic treatment plants with anaerobic digesters that avoids confusion when selecting the appropriate default MCF based on the Tier 1 IPCC guidelines. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Fuel conditioning facility electrorefiner start-up results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goff, K.M.; Mariani, R.D.; Vaden, D.
1996-05-01
At ANL-West, there are several thousand kilograms of metallic spent nuclear fuel containing bond sodium. This fuel will be treated in the Fuel Conditioning Facility (FCF) at ANL-West to produce stable waste forms for storage and disposal. The treatment operations will make use of an electrometallurgical process employing molten salts and liquid metals. The treatment equipment is presently undergoing testing with depleted uranium. Operations with irradiated fuel will commence when the environmental evaluation for FCF is complete.
2010-07-01
Department of Defense (DOD) are in great demand due to projected nationwide medical personnel shortages over the next decade and are essential to...for the first year, in order to assist the services in addressing near- term personnel shortages . It also provides a consistent staffing standard...dentists, medical service corps, and veterinarians , to name a few, at the work center level across Army fixed military treatment facilities. The model uses
VIEW OF THE INTERIOR OF BUILDING 774, THE ORIGINAL LIQUID ...
VIEW OF THE INTERIOR OF BUILDING 774, THE ORIGINAL LIQUID PROCESS WASTEWATER TREATMENT FACILITY. THE PHOTOGRAPH SHOWS STORAGE TANKS AND ASSOCIATED PLUTONIUM-CONTAMINATED SOLUTIONS. THE GLOVE BOX IS USED BY OPERATORS TO MANUALLY OPERATE PUMPS AND VALVES THAT REQUIRE PERIODIC ADJUSTMENT. OTHER VALVES IN THE ROOM WERE INFREQUENTLY ADJUSTED, AND ARE SEALED IN PLASTIC WRAP - Rocky Flats Plant, Waste Treatment Facility, Adjacent to bldg 771C, in northern portion of protected area, Golden, Jefferson County, CO
CHARACTERIZATION AND FATE OF PAH-CONTAMINATED SEDIMENTS AT THE WYCKOFF/EAGLE HARBOR SUPERFUND SITE
Eagle Harbor is a shallow marine embayment of Bainbridge Island, WA and formerly the site of the Wyckoff wood-treatment facility. The facility became operational in the early 1900s and used large quantities of creosote in its wood-treating processes. Creosote percolated through t...
Assessing Need for Medication-Assisted Treatment for Opiate-Dependent Prison Inmates
Albizu-García, Carmen E.; Caraballo, José Noel; Caraballo-Correa, Glorimar; Hernández-Viver, Adriana; Román-Badenas, Luis
2012-01-01
Individuals with a history of heroin dependence are overrepresented in American correctional facilities and 75% of inmates with a drug use disorder do not receive treatment during incarceration or after release. Medication-assisted treatment (MAT) with opiate agonists, such as methadone or buprenorphine, constitute standard of care; to guide planning for an expansion of drug treatment services in correctional facilities, a needs assessment was conducted at the Department of Correction and Rehabilitation (DCR) of Puerto Rico (PR). We report on the research process, the findings that informed our recommendations for the PCR to expand MAT for eligible inmates, and lessons learned. PMID:22263714
ENVIRONMENTAL MONITORING OF A WASTEWATER TREATMENT PLANT
A wastewater aerosol monitoring program was conducted at an advanced wastewater treatment facility using the activated sludge process. This plant was recently constructed next to an elementary school in Tigard, Oregon. Wastewater aerosols containing pathogenic organisms are gener...
9 CFR 590.575 - Heat treatment of dried whites.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Heat treatment of dried whites. 590..., Processing, and Facility Requirements § 590.575 Heat treatment of dried whites. Heat treatment of dried... and at such temperatures as will result in salmonella negative product. (a) The product to be heat...
9 CFR 590.575 - Heat treatment of dried whites.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Heat treatment of dried whites. 590..., Processing, and Facility Requirements § 590.575 Heat treatment of dried whites. Heat treatment of dried... and at such temperatures as will result in salmonella negative product. (a) The product to be heat...
9 CFR 590.575 - Heat treatment of dried whites.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Heat treatment of dried whites. 590..., Processing, and Facility Requirements § 590.575 Heat treatment of dried whites. Heat treatment of dried... and at such temperatures as will result in salmonella negative product. (a) The product to be heat...
ERIC Educational Resources Information Center
Wooley, John F.
Biological waste treatment in the activated sludge process is based on the ability of microorganisms to use dissolved oxygen in breaking down soluble organic substances. The oxygen uptake test is a means of measuring the respiration rate of microorganisms in this process. Designed for individuals who have completed National Pollutant Discharge…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Del Cul, G.D.; Osborne, P.E.; Beck, D.E.
1991-01-01
The Paducah Gaseous Diffusion Plant (PGDP) C-400 Decontamination Facility generates aqueous solutions that originate in drum washing, machine parts and equipment cleaning, and other decontamination processes. The chemical composition of the waste depends on the particular operation involved. In general, the waste contains uranyl, fluoride, carbonate, and nitrate ions, plus soaps, detergents, secondary contaminants, and particulate matter. The uranium content is rather variable ranging between 0.5 and 30 g/l. The main contaminants are fluoride, technetium, uranium, and other heavy metals. The plan included (1) a literature search to support best available technology (BAT) evaluation of treatment alternatives, (2) a qualitymore » assurance/quality control plan, (3) suggestion of alternative treatment options, (4) bench-scale tests studies of the proposed treatment alternatives, and (5) establishment of the final recommendation. The following report records the evaluation of items (1) to (3) of the action plan for the BAT evaluation of alternatives for the treatment and retreatment of uranium-contaminated wastewater at the PGDP C-400 treatment facility. After a thorough literature search, five major technologies were considered: (1) precipitation/coprecipitation, (2) reverse osmosis, (3) ultrafiltration, (4) supported liquid membranes, and (5) ion exchange. Biosorption was also considered, but as it is a fairly new technology with few demonstrations of its capabilities, it is mentioned only briefly in the report. Based on C-400's requirements and facilities, the precipitation/coprecipitation process appears to be the best suited for use at the plant. Four different treatment options using the precipitation/coprecipitation technology are proposed. Bench-scale studies of the four options are suggested. 37 refs.« less
Energy determination in industrial X-ray processing facilities
NASA Astrophysics Data System (ADS)
Cleland, M. R.; Gregoire, O.; Stichelbaut, F.; Gomola, I.; Galloway, R. A.; Schlecht, J.
2005-12-01
In industrial irradiation facilities, the determination of maximum photon or electron energy is important for regulated processes, such as food irradiation, and for assurance of treatment reproducibility. With electron beam irradiators, this has been done by measuring the depth-dose distribution in a homogeneous material. For X-ray irradiators, an analogous method has not yet been recommended. This paper describes a procedure suitable for typical industrial irradiation processes, which is based on common practice in the field of therapeutic X-ray treatment. It utilizes a measurement of the slope of the exponential attenuation curve of X-rays in a thick stack of polyethylene plates. Monte Carlo simulations and experimental tests have been performed to verify the suitability and accuracy of the method between 3 MeV and 8 MeV.
San Francisco Biofuel Program: Brown Grease to Biodiesel Demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jolis, Domènec; Martis, Mary; Jones, Bonnie
2013-03-01
Municipal wastewater treatment facilities have typically been limited to the role of accepting wastewater, treating it to required levels, and disposing of its treatment residuals. However, a new view is emerging which includes wastewater treatment facilities as regional resource recovery centers. This view is a direct result of increasingly stringent regulations, concerns over energy use, carbon footprint, and worldwide depletion of fossil fuel resources. Resources in wastewater include chemical and thermal energy, as well as nutrients, and water. A waste stream such as residual grease, which concentrates in the drainage from restaurants (referred to as Trap Waste), is a goodmore » example of a resource with an energy content that can be recovered for beneficial reuse. If left in wastewater, grease accumulates inside of the wastewater collection system and can lead to increased corrosion and pipe blockages that can cause wastewater overflows. Also, grease in wastewater that arrives at the treatment facility can impair the operation of preliminary treatment equipment and is only partly removed in the primary treatment process. In addition, residual grease increases the demand in treatment materials such as oxygen in the secondary treatment process. When disposed of in landfills, grease is likely to undergo anaerobic decay prior to landfill capping, resulting in the atmospheric release of methane, a greenhouse gas (GHG). This research project was therefore conceptualized and implemented by the San Francisco Public Utilities Commission (SFPUC) to test the feasibility of energy recovery from Trap Waste in the form of Biodiesel or Methane gas.« less
NASA Astrophysics Data System (ADS)
Rodriguez-Winter, Thelma
All man-made structures and materials have a design life. Across the United States there is a common theme for our water and wastewater treatment facilities and infrastructure. The design life of many of our mid 20 th century water and wastewater infrastructures in the United States have reached or are reaching life expectancy limits (ASCE, 2010). To compound the financial crisis of keeping up with the degradation, meeting and exceeding quality standards has never been more important in order to protect local fresh water supplies. This thesis analyzes the energy consumption of a municipal water and wastewater treatment system from a Lake Erie intake through potable treatment and back through wastewater treatment then discharge. The system boundary for this thesis includes onsite energy consumed by the treatment system and distribution/reclamation system as well as the energy consumed by the manufacturing of treatment chemicals applied during the study periods. By analyzing energy consumption, subsequent implications from greenhouse gas emissions and financial expenditures were quantified. Through the segregation of treatment and distribution processes from non-process energy consumption, such as heating, lighting, and air handling, this study identified that the potable water treatment system consumed an annual average of 2.42E+08 kBtu, spent 5,812,144 for treatment and distribution, and emitted 28,793 metric tons of CO2 equivalent emissions. Likewise, the wastewater treatment system consumed an annual average of 2.45E+08 kBtu, spent 3,331,961 for reclamation and treatment, and emitted 43,780 metric tons of CO2 equivalent emissions. The area with the highest energy usage, financial expenditure, and greenhouse gas emissions for the potable treatment facility and distribution system was from the manufacturing of the treatment chemicals, 1.10E+08 kBtu, 3.7 million, and 17,844 metric tons of CO2 equivalent, respectively. Of the onsite energy (1.4E-03 kWh per gallon treated) 74% is process energy and 26% is non-process energy. Sixty-six percent of the process energy is consumed by the main treatment facility and high service distribution. When analyzing seasonal variations, the highest amount of process energy treated the largest amount of potable water with the maxiμm revealing four Btu used per gallon treated while utilizing 54% of the design capacity. Compared to the periods when the lowest amount of the design capacity was utilized, 32 - 33%, the facility consumed the seasonal high in energy, approximately 6.7 Btu per gallon treated. For the wastewater treatment and reclamation side, secondary treatment dominates all 3 categories by consuming 81,701,764 kBtu, 1.1 million, and 32,395 metric tons of CO2 equivalent. The total onsite energy was 2.79E-03 kWh per gallon treated, of which 43% was process energy, and the remainder was consumed by natural gas heating and `other non-process and process' energy, 34% and 23%, respectively. Most significantly during the months of April and May, when the influent flow of wastewater doubles and is diluted due to the addition of seasonal rain water, the amount of energy spent per gallon of treated wastewater decreases by 48% and 34% from the maximum (5.03E-03 kWh/gallon). By functioning closer to a forecasted design capacity, the efficiency of the potable water treatment facility could be dramatically improved. This can be achieved by implementing additional storage of ready-to-use potable water and/or by expanding the customer base and collaborating with other regional potable water utilities. For example, a county-wide approach to potable water planning falls into agreement with sustainable planning methods, providing regions of the county that have maximized treatment capacity of potable water and giving this region the opportunity to operate closer to the intended design capacity. On the wastewater treatment side, it is apparent that the more dense the BOD concentration in influent waters the more energy is spent in secondary treatment trying to remove it. Exploring more effective screening and pre-precipitation methods could also prove to save a significant amount in energy spent in the secondary treatment step, reducing the organic load prior to aeration. Coupling this with aeration blower and diffuser improvements can offer significant energy savings. Further water quality data and energy use data needs to be collected and analyzed on the individual wastewater treatment processes, especially regarding the impact and effectiveness of the preliminary and primary treatment steps on secondary treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terusaki, Stanley; Gallegos, Gretchen; MacQueen, Donald
2012-10-02
LLNL Site 300 has applied to renew the permits for its Explosives Waste Treatment Facility (EWTF), Explosives Waste Storage Facility (EWSF) and Building 883 Storage Facility. As a part of the permit renewal process, the Department of Toxic Substances Control (DTSC) requested LLNL to obtain soil samples in order to conduct a scoping-level ecological risk assessment pursuant to the Department of Toxic Substances Control, Guidance for Ecological Risk Assessment at Hazardous Waste Sites and Permitted Facilities, Part A: Overview, July 4, 1996. As stated in the guidance document, the scoping-level ecological risk assessment provides a framework to determine the potentialmore » interaction ecological receptors and chemicals of concern from hazardous waste treatment operations in the area of EWTF.« less
Technology Readiness Assessment of a Large DOE Waste Processing Facility
2007-09-12
Waste Generation at Hanford – Waste Treatment and Immobilization Plant ( WTP ) Project • Motivation to Conduct TRA • TRA Approach • Actions to ensure...Hanford’s WTP will be the world’s largest radioactive waste treatment plant to treat Hanford’s underground tank waste Waste Treatment Plant ( WTP ) Major...Mass Maximize Activity WTP Flow Sheet – Key Process Flows Hanford Tank Waste 10 How is the Vitrified Waste Dispositioned? High Level Waste Canisters
Rates of inactivation of waterborne coliphages by monochloramine.
Dee, S W; Fogleman, J C
1992-01-01
A sophisticated water quality monitoring program was established to evaluate virus removal through Denver's 1-million-gal (ca. 4-million-liter)/day Direct Potable Reuse Demonstration Plant. As a comparison point for the reuse demonstration plant, Denver's main water treatment facility was also monitored for coliphage organisms. Through the routine monitoring of the main plant, it was discovered that coliphage organisms were escaping the water treatment processes. Monochloramine residuals and contact times (CT values) required to achieve 99% inactivation were determined for coliphage organisms entering and leaving this conventional water treatment plant. The coliphage tested in the effluent waters had higher CT values on the average than those of the influent waters. CT values established for some of these coliphages suggest that monochloramine alone is not capable of removing 2 orders of magnitude of these specific organisms in a typical water treatment facility. Electron micrographs revealed one distinct type of phage capable of escaping the water treatment processes and three distinct types of phages in all. Images PMID:1444427
Health hazard evaluation report HETA 82-387-1392, Exxon Corporation, Baton Rouge, Louisiana
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ratcliffe, J.M.; Rosenberg, M.J.; Fox, S.H.
1983-12-01
In response to a request from an authorized representative of employees at the Exxon Corporation, Baton Rouge, Louisiana, an investigation was begun into a possible reproductive health hazard at the refinery waste water treatment facility. The refinery processed crude petroleum into a variety of products, processing about 500,000 barrels of crude oil each day. The men had noted what seemed to be an excessive number of spontaneous abortions occurring among their wives. A cross sectional evaluation of sperm concentration and sperm morphology was conducted in wastewater treatment facility workers and two control groups (those who worked in other portions ofmore » the refinery and administrative personnel who did not work in the refinery itself). Of the 68 men employed in the wastewater treatment facility during the 6 month period before this study, six were not eligible for the study. Semen samples were provided by 42 of the 62 eligible men, and by 73 control subjects. After data adjustment for abstinence period, the mean sperm concentration of the unexposed group did not differ significantly from that of the 42 exposed men.« less
Microplastic pollution is widely detected in US municipal wastewater treatment plant effluent.
Mason, Sherri A; Garneau, Danielle; Sutton, Rebecca; Chu, Yvonne; Ehmann, Karyn; Barnes, Jason; Fink, Parker; Papazissimos, Daniel; Rogers, Darrin L
2016-11-01
Municipal wastewater effluent has been proposed as one pathway for microplastics to enter the aquatic environment. Here we present a broad study of municipal wastewater treatment plant effluent as a pathway for microplastic pollution to enter receiving waters. A total of 90 samples were analyzed from 17 different facilities across the United States. Averaging all facilities and sampling dates, 0.05 ± 0.024 microparticles were found per liter of effluent. Though a small value on a per liter basis, even minor municipal wastewater treatment facilities process millions of liters of wastewater each day, yielding daily discharges that ranged from ∼50,000 up to nearly 15 million particles. Averaging across the 17 facilities tested, our results indicate that wastewater treatment facilities are releasing over 4 million microparticles per facility per day. Fibers and fragments were found to be the most common type of particle within the effluent; however, some fibers may be derived from non-plastic sources. Considerable inter- and intra-facility variation in discharge concentrations, as well as the relative proportions of particle types, was observed. Statistical analysis suggested facilities serving larger populations discharged more particles. Results did not suggest tertiary filtration treatments were an effective means of reducing discharge. Assuming that fragments and pellets found in the effluent arise from the 'microbeads' found in many cosmetics and personal care products, it is estimated that between 3 and 23 billion (with an average of 13 billion) of these microplastic particles are being released into US waterways every day via municipal wastewater. This estimate can be used to evaluate the contribution of microbeads to microplastic pollution relative to other sources (e.g., plastic litter and debris) and pathways (e.g., stormwater) of discharge. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Camper, Larry W.; Michalak, Paul; Cohen, Stephen
Community Water Systems (CWSs) are required to remove uranium from drinking water to meet EPA standards. Similarly, mining operations are required to remove uranium from their dewatering discharges to meet permitted surface water discharge limits. Ion exchange (IX) is the primary treatment strategy used by these operations, which loads uranium onto resin beads. Presently, uranium-loaded resin from CWSs and mining operations can be disposed as a waste product or processed by NRC- or Agreement State-licensed uranium recovery facilities if that licensed facility has applied for and received permission to process 'alternate feed'. The disposal of uranium-loaded resin is costly andmore » the cost to amend a uranium recovery license to accept alternate feed can be a strong disincentive to commercial uranium recovery facilities. In response to this issue, the NRC issued a Regulatory Issue Summary (RIS) to clarify the agency's policy that uranium-loaded resin from CWSs and mining operations can be processed by NRC- or Agreement State-licensed uranium recovery facilities without the need for an alternate feed license amendment when these resins are essentially the same, chemically and physically, to resins that licensed uranium recovery facilities currently use (i.e., equivalent feed). NRC staff is clarifying its current alternate feed policy to declare IX resins as equivalent feed. This clarification is necessary to alleviate a regulatory and financial burden on facilities that filter uranium using IX resin, such as CWSs and mine dewatering operations. Disposing of those resins in a licensed facility could be 40 to 50 percent of the total operations and maintenance (O and M) cost for a CWS. Allowing uranium recovery facilities to treat these resins without requiring a license amendment lowers O and M costs and captures a valuable natural resource. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jantzen, C.; Crawford, C.; Cozzi, A.
The U.S. Department of Energy's Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford's tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in themore » time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. The Supplemental Treatment chosen will immobilize that portion of the retrieved LAW that is not sent to the WTP's LAW Vitrification facility into a solidified waste form. The solidified waste will then be disposed on the Hanford site in the Integrated Disposal Facility (IDF). In addition, the WTP LAW vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as Cs-137, I-129, Tc-99, Cl, F, and SO4 that volatilize at the vitrification temperature of 1150 C in the absence of a continuous cold cap. The current waste disposal path for the WTP-SW is to recycle it to the supplemental LAW treatment to avoid a large steady state accumulation in the pretreatment-vitrification loop. Fluidized Bed Steam Reforming (FBSR) offers a moderate temperature (700-750 C) continuous method by which LAW and/or WTP-SW wastes can be processed irrespective of whether they contain organics, nitrates, sulfates/sulfides, chlorides, fluorides, volatile radionuclides or other aqueous components. The FBSR technology can process these wastes into a crystalline ceramic (mineral) waste form. The mineral waste form that is produced by co-processing waste with kaolin clay in an FBSR process has been shown to be as durable as LAW glass. Monolithing of the granular FBSR product is being investigated to prevent dispersion during transport or burial/storage but is not necessary for performance. A Benchscale Steam Reformer (BSR) was designed and constructed at the Savannah River National Laboratory (SRNL) to treat actual radioactive wastes to confirm the findings of the non-radioactive FBSR pilot scale tests and to qualify the waste form for applications at Hanford. Radioactive testing commenced in 2010 with a demonstration of Hanford's WTP-SW where Savannah River Site (SRS) High Level Waste (HLW) secondary waste from the Defense Waste Processing Facility (DWPF) was shimmed with a mixture of I-125/129 and Tc-99 to chemically resemble WTP-SW. Ninety six grams of radioactive product were made for testing. The second campaign commenced using SRS LAW chemically trimmed to look like Hanford's LAW. Six hundred grams of radioactive product were made for extensive testing and comparison to the non-radioactive pilot scale tests. The same mineral phases were found in the radioactive and non-radioactive testing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C.; Burket, P.; Cozzi, A.
2012-02-02
The U.S. Department of Energy's Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford's tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in themore » time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. In addition, the WTP LAW vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as {sup 137}Cs, {sup 129}I, {sup 99}Tc, Cl, F, and SO{sub 4} that volatilize at the vitrification temperature of 1150 C in the absence of a continuous cold cap (that could minimize volatilization). The current waste disposal path for the WTP-SW is to process it through the Effluent Treatment Facility (ETF). Fluidized Bed Steam Reforming (FBSR) is being considered for immobilization of the ETF concentrate that would be generated by processing the WTP-SW. The focus of this current report is the WTP-SW. FBSR offers a moderate temperature (700-750 C) continuous method by which WTP-SW wastes can be processed irrespective of whether they contain organics, nitrates, sulfates/sulfides, chlorides, fluorides, volatile radionuclides or other aqueous components. The FBSR technology can process these wastes into a crystalline ceramic (mineral) waste form. The mineral waste form that is produced by co-processing waste with kaolin clay in an FBSR process has been shown to be as durable as LAW glass. Monolithing of the granular FBSR product is being investigated to prevent dispersion during transport or burial/storage, but is not necessary for performance. A Benchscale Steam Reformer (BSR) was designed and constructed at the SRNL to treat actual radioactive wastes to confirm the findings of the non-radioactive FBSR pilot scale tests and to qualify the waste form for applications at Hanford. BSR testing with WTP SW waste surrogates and associated analytical analyses and tests of granular products (GP) and monoliths began in the Fall of 2009, and then was continued from the Fall of 2010 through the Spring of 2011. Radioactive testing commenced in 2010 with a demonstration of Hanford's WTP-SW where Savannah River Site (SRS) High Level Waste (HLW) secondary waste from the Defense Waste Processing Facility (DWPF) was shimmed with a mixture of {sup 125/129}I and {sup 99}Tc to chemically resemble WTP-SW. Prior to these radioactive feed tests, non-radioactive simulants were also processed. Ninety six grams of radioactive granular product were made for testing and comparison to the non-radioactive pilot scale tests. The same mineral phases were found in the radioactive and non-radioactive testing.« less
40 CFR 80.84 - Treatment of interface and transmix.
Code of Federal Regulations, 2010 CFR
2010-07-01
... processing facility means any refinery that produces TGP from transmix by distillation or other refining processes, but does not produce gasoline by processing crude oil. (5) Transmix processor means any person... Test Method for Distillation of Petroleum Products at Atmospheric Pressure”, which is incorporated by...
40 CFR 270.65 - Research, development, and demonstration permits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) EPA ADMINISTERED PERMIT PROGRAMS: THE HAZARDOUS WASTE PERMIT PROGRAM... may issue a research, development, and demonstration permit for any hazardous waste treatment facility which proposes to utilize an innovative and experimental hazardous waste treatment technology or process...
40 CFR 270.65 - Research, development, and demonstration permits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) SOLID WASTES (CONTINUED) EPA ADMINISTERED PERMIT PROGRAMS: THE HAZARDOUS WASTE PERMIT PROGRAM... may issue a research, development, and demonstration permit for any hazardous waste treatment facility which proposes to utilize an innovative and experimental hazardous waste treatment technology or process...
Hurst, C. J.
1991-01-01
A review of results published in English or French between 1980 and 1990 was carried out to determine the levels of indigenous human enteric viruses in untreated surface and subsurface freshwaters, as well as in drinking water that had undergone the complete conventional treatment process. For this purpose, the conventional treatment process was defined as an operation that included coagulation followed by sedimentation, filtration, and disinfection. Also assessed was the stepwise efficiency of the conventional treatment process, as practised at full-scale facilities, for removing indigenous viruses from naturally occurring freshwaters. A list was compiled of statistical correlations relating to the occurrence of indigenous viruses in water. PMID:1647273
Next Generation Loading System for Detonators and Primers
Designed , fabricated and installed next generation tooling to provide additional manufacturing capabilities for new detonators and other small...prototype munitions on automated, semi-automated and manual machines. Lead design effort, procured and installed a primary explosive Drying Oven for a pilot...facility. Designed , fabricated and installed a Primary Explosives Waste Treatment System in a pilot environmental processing facility. Designed
On-site or off-site treatment of medical waste: a challenge
2014-01-01
Treating hazardous-infectious medical waste can be carried out on-site or off-site of health-care establishments. Nevertheless, the selection between on-site and off-site locations for treating medical waste sometimes is a controversial subject. Currently in Iran, due to policies of Health Ministry, the hospitals have selected on-site-treating method as the preferred treatment. The objectives of this study were to assess the current condition of on-site medical waste treatment facilities, compare on-site medical waste treatment facilities with off-site systems and find the best location of medical waste treatment. To assess the current on-site facilities, four provinces (and 40 active hospitals) were selected to participate in the survey. For comparison of on-site and off-site facilities (due to non availability of an installed off-site facility) Analytical Hierarchy Process (AHP) was employed. The result indicated that most on-site medical waste treating systems have problems in financing, planning, determining capacity of installations, operation and maintenance. AHP synthesis (with inconsistency ratio of 0.01 < 0.1) revealed that, in total, the off-site treatment of medical waste was in much higher priority than the on-site treatment (64.1% versus 35.9%). According to the results of study it was concluded that the off-site central treatment can be considered as an alternative. An amendment could be made to Iran’s current medical waste regulations to have infectious-hazardous waste sent to a central off-site installation for treatment. To begin and test this plan and also receive the official approval, a central off-site can be put into practice, at least as a pilot in one province. Next, if it was practically successful, it could be expanded to other provinces and cities. PMID:24739145
Fate of cyanobacteria in drinking water treatment plant lagoon supernatant and sludge.
Pestana, Carlos J; Reeve, Petra J; Sawade, Emma; Voldoire, Camille F; Newton, Kelly; Praptiwi, Radisti; Collingnon, Lea; Dreyfus, Jennifer; Hobson, Peter; Gaget, Virginie; Newcombe, Gayle
2016-09-15
In conventional water treatment processes, where the coagulation and flocculation steps are designed to remove particles from drinking water, cyanobacteria are also concentrated into the resultant sludge. As a consequence, cyanobacteria-laden sludge can act as a reservoir for metabolites such as taste and odour compounds and cyanotoxins. This can pose a significant risk to water quality where supernatant from the sludge treatment facility is returned to the inlet to the plant. In this study the complex processes that can take place in a sludge treatment lagoon were investigated. It was shown that cyanobacteria can proliferate in the conditions manifest in a sludge treatment lagoon, and that cyanobacteria can survive and produce metabolites for at least 10days in sludge. The major processes of metabolite release and degradation are very dependent on the physical, chemical and biological environment in the sludge treatment facility and it was not possible to accurately model the net effect. For the first time evidence is provided to suggest that there is a greater risk associated with recycling sludge supernatant than can be estimated from the raw water quality, as metabolite concentrations increased by up to 500% over several days after coagulation, attributed to increased metabolite production and/or cell proliferation in the sludge. Copyright © 2016 Elsevier B.V. All rights reserved.
40 CFR 436.21 - Specialized definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... natural deposits. (e) The term “process generated waste water” shall mean any waste water used in the... of the mine operator. However, if a mine is also used for treatment of process generated waste water, discharges of commingled water from the facilities shall be deemed discharges of process generated waste...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoskinson, R.L.
1994-01-01
This report summarizes a study conducted using the Arc/Info{reg_sign} geographic information system (GIS) to analyze the criteria used for site selection for the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of the analyses was to determine, based on predefined criteria, the areas on the INEL that best satisfied the criteria. The coverages used in this study were produced by importing the AutoCAD files that produced the maps for a pre site selection draft report into the GIS. The files were then converted to Arc/Info{reg_sign} GIS format. The initial analysis was mademore » by considering all of the criteria as having equal importance in determining the areas of the INEL that would best satisfy the requirements. Another analysis emphasized four of the criteria as ``must`` criteria which had to be satisfied. Additional analyses considered other criteria that were considered for, but not included in the predefined criteria. This GIS analysis of the siting criteria for the IWPF and MLLWTF provides a logical, repeatable, and defensible approach to the determination of candidate locations for the facilities. The results of the analyses support the location of the Candidate Locations.« less
Canadian Innovations in Siting Hazardous Waste Management Facilities
Kuhn; Ballard
1998-07-01
/ Siting hazardous waste facilities is an extremely complex and difficult endeavor. Public aversion to the construction of these facilities in or near their community often results in concerted opposition, referred to as the NIMBY syndrome. For the most part, siting processes do not fail because of inadequate environmental or technical considerations, but because of the adversarial decision-making strategies employed by the proponents. Innovative siting processes used in the provinces of Alberta and Manitoba offer tangible evidence of the successful application of an innovative siting approach based on the principles of decentralization of decision-making authority and full and meaningful public involvement. The purpose of this paper is to evaluate four Canadian siting processes from the perspective of public participation and access to decision-making authority. Examples of siting processes related to hazardous waste management facilities are provided from the provinces of Alberta, Manitoba, British Columbia, and Ontario. Siting has evolved from approaches dominated by top-down decision making to increasing decentralized and pluralistic approaches. Focusing on social and political concerns of potentially affected communities and on the process of decision making itself are fundamental to achieving siting success. In Alberta initially, and later in Manitoba, this new "open approach" to siting has resulted in the construction of the first two comprehensive hazardous waste treatment facilities in Canada.KEY WORDS: Hazardous waste facilities; Siting methodologies; Public participation
20. VIEW OF WASTE TREATMENT CONTROL ROOM IN BUILDING 374. ...
20. VIEW OF WASTE TREATMENT CONTROL ROOM IN BUILDING 374. THE BUILDING 371/374 COMPLEX WAS DESIGNED TO EMPHASIZE AUTOMATICALLY CONTROLLED, REMOTELY OPERATED PROCESSES. (1/80) - Rocky Flats Plant, Plutonium Recovery Facility, Northwest portion of Rocky Flats Plant, Golden, Jefferson County, CO
40 CFR 98.350 - Definition of source category.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Industrial Wastewater Treatment § 98.350 Definition of source category. (a) This source category consists of anaerobic processes used to treat industrial wastewater and industrial wastewater treatment sludge at facilities that perform the operations listed in this paragraph. (1...
40 CFR 98.350 - Definition of source category.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Industrial Wastewater Treatment § 98.350 Definition of source category. (a) This source category consists of anaerobic processes used to treat industrial wastewater and industrial wastewater treatment sludge at facilities that perform the operations listed in this paragraph. (1...
40 CFR 98.350 - Definition of source category.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Industrial Wastewater Treatment § 98.350 Definition of source category. (a) This source category consists of anaerobic processes used to treat industrial wastewater and industrial wastewater treatment sludge at facilities that perform the operations listed in this paragraph. (1...
40 CFR 98.350 - Definition of source category.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) MANDATORY GREENHOUSE GAS REPORTING Industrial Wastewater Treatment § 98.350 Definition of source category. (a) This source category consists of anaerobic processes used to treat industrial wastewater and industrial wastewater treatment sludge at facilities that perform the operations listed in this paragraph. (1...
Planning of Eka Hospital Pekanbaru wastewater recycling facility
NASA Astrophysics Data System (ADS)
Jecky, A.; Andrio, D.; Sasmita, A.
2018-04-01
The Ministry of Public Works No. 06 2011 required the large scale of water to conserve the water resource, Eka Hospital Pekanbaru have to improve the sewage treatment plant through the wastewater recycling. The effluent from the plant can be used to landscape gardening and non-potable activities. The wastewater recycling design was done by analyzing the existing condition of thesewage treatment plant, determine the effluent quality standards for wastewater recycling, selected of alternative technology and processing, design the treatment unit and analyze the economic aspects. The design of recycling facility by using of combination cartridge filters processing, ultrafiltration membranes, and desinfection by chlorination. The wastewater recycling capacity approximately of 75 m3/day or 75% of the STP effluent. The estimated costs for installation of wastewater recycling and operation and maintenance per month are Rp 111,708,000 and Rp 2,498,000 respectively.
Facile Dry Surface Cleaning of Graphene by UV Treatment
NASA Astrophysics Data System (ADS)
Kim, Jin Hong; Haidari, Mohd Musaib; Choi, Jin Sik; Kim, Hakseong; Yu, Young-Jun; Park, Jonghyurk
2018-05-01
Graphene has been considered an ideal material for application in transparent lightweight wearable electronics due to its extraordinary mechanical, optical, and electrical properties originating from its ordered hexagonal carbon atomic lattice in a layer. Precise surface control is critical in maximizing its performance in electronic applications. Graphene grown by chemical vapor deposition is widely used but it produces polymeric residue following wet/chemical transfer process, which strongly affects its intrinsic electrical properties and limits the doping efficiency by adsorption. Here, we introduce a facile dry-cleaning method based on UV irradiation to eliminate the organic residues even after device fabrication. Through surface topography, Raman analysis, and electrical transport measurement characteristics, we confirm that the optimized UV treatment can recover the clean graphene surface and improve graphene-FET performance more effectively than thermal treatment. We propose our UV irradiation method as a systematically controllable and damage-free post process for application in large-area devices.
Occurrence of Pharmaceuticals in Calgary's Wastewater and Related Surface Water.
Chen, M; Cooper, V I; Deng, J; Amatya, P L; Ambrus, D; Dong, S; Stalker, N; Nadeau-Bonilla, C; Patel, J
2015-05-01
The influents/effluents from Calgary's water resource recovery facilities and the surface water were analyzed for pharmaceuticals in the present study. The median concentrations in the effluents for the 15 targeted pharmaceuticals were within the range of 0.006 to 3.32 ppb. Although the wastewater treatment facilities were not designed to remove pharmaceuticals, this study indicates that the wastewater treatment processes are effective in removing some of the pharmaceuticals from the aqueous phase. The removal rate estimated can be 99.5% for caffeine, whereas little or no removal was observed for carbamazepine. Biodegradation, chemical degradation, and sorption could be some of the mechanisms responsible for the removal of pharmaceuticals. The drug residues in downstream surface water could be associated with incomplete removal of pharmaceuticals during the treatment process and may lead to concerns in terms of potential impacts on the aquatic ecosystem. However, this study does not indicate any immediate risks to the downstream aquatic environment.
Is bigger better? Driving factors of POTW performance in New York.
Rahm, Brian G; Morse, Natalie; Bowen, Michelle; Choi, Jun; Mehta, Dhaval; Vedachalam, Sridhar
2018-05-15
Like many regions around the world, New York State, USA, faces challenges in meeting wastewater treatment quality standards because of aging infrastructure, limited funding, shifting demographics and increasingly stringent environmental regulations. In recent decades construction of new wastewater treatment and distribution infrastructure in NY has most often occurred in exurban communities and suburban developments that are less dense than traditional urban cores. Here, we examine the role of size and capacity utilization on wastewater treatment effectiveness with respect to critical effluent parameters, and additionally explore which common facility engineering controls influence water quality treatment using a unique dataset of descriptive information. Our results challenge conventional wisdom, suggesting that the largest facilities (>30,000 m 3 /d), not the smallest (<300 m 3 /d), discharge TSS, BOD, and coliform at significantly higher relative effluent concentrations (i.e., the ratio of discharged concentrations to allowable limits). Capacity utilization was also positively correlated to higher concentrations of TSS, BOD, and coliform effluent concentrations in larger facilities, though those concentrations were often within regulated limits. This implies that smaller-sized facilities may perform better in terms of environmental quality, but that the largest facilities demonstrate efficiency in the sense that they are not "over-treating" wastewater while avoiding violations. Results from NY suggest that medium sized facilities (300-30,000 m 3 /d) are sophisticated enough to incorporate appropriate unit processes, and employ operators with sufficient training and oversight, to reach treatment outcomes that are both reliable and of high quality. Copyright © 2018 Elsevier Ltd. All rights reserved.
Korean Waste Management Law and Waste Disposal Forms.
1991-03-01
disinfection facility, dewatering facility, and other auxiliary facilities 2) An aerobic treatment facility composed of intake, detention basin, aerobic ... digestion or oxidation treatment facility, biological treatment facility, disinfection facility, dewatering facility, and other auxiliary facilities
ERIC Educational Resources Information Center
Carnegie, John W.
This module describes the process used to determine solids mass and location throughout a waste water treatment plant, explains how these values are used to determine the solids mass balance around single treatment units and the entire system, and presents calculations of solids in pounds and sludge units. The instructor's manual contains a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freihammer, Till; Chaput, Barb; Vandergaast, Gary
2013-07-01
The Port Granby Project is part of the larger Port Hope Area Initiative, a community-based program for the development and implementation of a safe, local, long-term management solution for historic low level radioactive waste (LLRW) and marginally contaminated soils (MCS). The Port Granby Project involves the relocation and remediation of up to 0.45 million cubic metres of such waste from the current Port Granby Waste Management Facility located in the Municipality of Clarington, Ontario, adjacent to the shoreline of Lake Ontario. The waste material will be transferred to a new suitably engineered Long-Term Waste Management Facility (LTWMF) to be locatedmore » inland approximately 700 m from the existing site. The development of the LTWMF will include construction and commissioning of a new Wastewater Treatment Plant (WWTP) designed to treat wastewater consisting of contaminated surface run off and leachate generated during the site remediation process at the Port Granby Waste Management Facility as well as long-term leachate generated at the new LTWMF. Numerous factors will influence the variable wastewater flow rates and influent loads to the new WWTP during remediation. The treatment processes will be comprised of equalization to minimize impacts from hydraulic peaks, fine screening, membrane bioreactor technology, and reverse osmosis. The residuals treatment will comprise of lime precipitation, thickening, dewatering, evaporation and drying. The distribution of the concentration of uranium and radium - 226 over the various process streams in the WWTP was estimated. This information was used to assess potential worker exposure to radioactivity in the various process areas. A mass balance approach was used to assess the distribution of uranium and radium - 226, by applying individual contaminant removal rates for each process element of the WTP, based on pilot scale results and experience-based assumptions. The mass balance calculations were repeated for various flow and load scenarios. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moak, Don J.; Grondin, Richard L.; Triner, Glen C.
CH2M Hill Plateau Remediation Company (CHRPC) is a prime contractor to the U.S. Department of Energy (DOE) focused on the largest ongoing environmental remediation project in the world at the DOE Hanford Site Central Plateau, i.e. the DOE Hanford Plateau Remediation Contract. The East Tennessee Materials and Energy Corporation (M and EC); a wholly owned subsidiary of Perma-Fix Environmental Services, Inc. (PESI), is a small business team member to CHPRC. Our scope includes project management; operation and maintenance of on-site storage, repackaging, treatment, and disposal facilities; and on-site waste management including waste receipt from generators and delivery to on-site andmore » off-site treatment, storage, and disposal facilities. As part of this scope, M and EC staffs the centralized Waste Support Services organization responsible for all waste characterization and acceptance required to support CHPRC and waste generators across the Hanford Site. At the time of the CHPRC contract award (August 2008) slightly more than 9,000 cubic meters (m{sup 3}) of legacy waste was defined as 'no-path-forward waste'. A significant portion of this waste (7,650 m{sup 3}) comprised wastes with up to 50 grams of special nuclear materials (SNM) in oversized packages recovered during retrieval operations and large glove boxes removed from the Plutonium Finishing Plant (PFP). Through a collaborative effort between the DOE, CHPRC, and Perma-Fix Environmental Services, Inc. (PESI), pathways for these problematic wastes were developed that took advantage of commercial treatment capabilities at a nearby vendor facility, Perma-Fix Northwest (PFNW). In the spring of 2009, CHPRC initiated a pilot program under which they began shipping large package, low gram suspect TRU (<15 g SNM per container), and large package contact and remote handled MLLW to the off-site PFNW facility for treatment. PFNW is restricted by the SNM limits set for the total quantity of SNM allowed at the facility in accordance with the facility's radioactive materials license(s) (RML). While both CHPRC and PFNW maintain waste databases to track all waste movements, it became evident early in the process that a tool was needed that married the two systems to better track SNM inventories and sequence waste from the point of generation, through the PFNW facility, and back to the Hanford site for final disposition. This tool, known as the Treatment Integration and Planning Tool (TIPT), has become a robust planning tool that provides real-time data to support compliant and efficient waste generation, transportation, treatment, and disposition. TIPT is developing into the next generation tool that will change the way in which legacy wastes, retrieval wastes and decontamination and decommissioning operations are conducted on the Plateau Remediation Contract (PRC). The real value of the TIPT is its predictive capability. It allows the W and FMP to map out optimal windows for processing waste through the PFNW facility, or through any process that is in some way resource limited. It allows project managers to identify and focus on problem areas before shipments are affected. It has been modified for use in broader applications to predict turnaround times and identify windows of opportunity for processing higher gram wastes through PFNW and to allow waste generators, site-wide, to accurately predict scope, cost, and schedule for waste generation to optimize processing and eliminate storage, double handling, and related costs and unnecessary safety risks. The TIPT addresses the years old problem of how to effectively predict not only what needs to be done, but when. 'When' is the key planning parameter that has been ignored by the generator and processor for many years, but has proven to be the most important parameter for both parties. While further refinement is a natural part of any development process, the current improvements on the TIPT have shown that prediction is a powerful consideration. Even in lean times expected for the foreseeable future, the improved TIPT continues to play a central role in managing our way through those times to assure facilities remain viable and available. It is recommended that other major remediation projects and waste processing facilities incorporate a tool such as TIPT to improve customer-commercial supplier communications and better optimization of resources. (authors)« less
Process Design Manual for Nitrogen Control.
ERIC Educational Resources Information Center
Parker, Denny S.; And Others
This manual presents theoretical and process design criteria for the implementation of nitrogen control technology in municipal wastewater treatment facilities. Design concepts are emphasized through examination of data from full-scale and pilot installations. Design data are included on biological nitrification and denitrification, breakpoint…
40 CFR 240.201-2 - Recommended procedures: Design.
Code of Federal Regulations, 2010 CFR
2010-07-01
... carcasses, automobile bodies, dewatered sludges from water treatment plants, and industrial process wastes. ... WASTES GUIDELINES FOR THE THERMAL PROCESSING OF SOLID WASTES Requirements and Recommended Procedures... or excluded wastes inadvertently left at the facility should be considered in design. (b) Examples of...
Commonwealth of Pennsylvania. [Establishment of hazardous waste facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Environmental Resources Secretary Arthur A. Davis and Commerce Secretary Raymond R. Christman have announced a joint initiative to establish commercial hazardous waste treatment and disposal facilities Pennsylvania. The state Hazardous Sites Cleanup Act, which Gov. Robert P. Casey signed into law last October, called for accelerated efforts in this regard. These included an expedited permitting process for facilities, requiring the Department of Environmental Resources (DER) to appoint a special sitting team to review permit applications, and designation of sitting coordinator within the Department of Commerce to identify potential developers of the facilities and encourage them to operate within Pennsylvania.
NASA Technical Reports Server (NTRS)
1991-01-01
Stennis Space Center's aquaculture research program has led to an attractive wastewater treatment for private homes. The system consists of a septic tank or tanks for initial sewage processing and a natural secondary treatment facility for further processing of septic tanks' effluent, consisting of a narrow trench, which contains marsh plants and rocks, providing a place for microorganisms. Plants and microorganisms absorb and digest, thus cleansing partially processed wastewater. No odors are evident and cleaned effluent may be discharged into streams or drainage canals. The system is useful in rural areas, costs about $1,900, and requires less maintenance than mechanical systems.
3718-F Alkali Metal Treatment and Storage Facility Closure Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Since 1987, Westinghouse Hanford Company has been a major contractor to the U.S. Department of Energy-Richland Operations Office and has served as co-operator of the 3718-F Alkali Metal Treatment and Storage Facility, the waste management unit addressed in this closure plan. The closure plan consists of a Part A Dangerous waste Permit Application and a RCRA Closure Plan. An explanation of the Part A Revision (Revision 1) submitted with this document is provided at the beginning of the Part A section. The closure plan consists of 9 chapters and 5 appendices. The chapters cover: introduction; facility description; process information; wastemore » characteristics; groundwater; closure strategy and performance standards; closure activities; postclosure; and references.« less
Yap, Glenn A; Platonova, Elena A; Musa, Philip F
2006-02-01
An exploratory study used Ansoff's strategic planning model as a framework to assess perceived effectiveness of information systems in supporting strategic business plan development at Air Force medical treatment facilities (MTFs). Results showed information systems were most effective in supporting historical trend analysis, strategic business plans appeared to be a balance of operational and strategic plans, and facilities perceived a greater need for new clinical, vice administrative, information systems to support strategic planning processes. Administrators believed information systems should not be developed at the local level and perceived information systems have the greatest impact on improving clinical quality outcomes, followed by ability to deliver cost effective care and finally, ability to increase market share.
Güneş, Elçin; Çifçi, Deniz İzlen; Çelik, Suna Özden
2018-04-01
The present study aims to explore the characterization of industrial container and drum cleaning (ICDC) industry wastewater and treatment alternatives of this wastewater using Fenton and adsorption processes. Wastewater derived from ICDC industry is usually treated by chemical coagulation and biological treatment in Turkey and then discharged in a centralized wastewater treatment facility. It is required that the wastewater COD is below 1500 mg/L to treat in a centralized wastewater treatment facility. The wastewater samples were characterized for parameters of pH, conductivity, COD, BOD 5 , TSS, NH 3 -N, TN, TOC, TP, Cd, Cr, Cu, Fe, Ni, Pb, Zn, and Hg. Initial COD values were in the range of 11,300-14,200 mg/L. The optimum conditions for Fenton treatment were 35-40 g/L for H 2 O 2 , 2-5 g/L for Fe 2+ , and 13-36 for H 2 O 2 /Fe 2+ molar ratio. The optimum conditions of PAC doses and contact times in adsorption studies were 20-30 g/L and 5-12 h, respectively. Removal efficiencies of characterized parameters for the three samples were compared for both Fenton and adsorption processes under optimum conditions. The results suggest that these wastewaters are suitable for discharge to a centralized wastewater treatment plant.
Process Design Manual: Wastewater Treatment Facilities for Sewered Small Communities.
ERIC Educational Resources Information Center
Leffel, R. E.; And Others
This manual attempts to describe new treatment methods, and discuss the application of new techniques for more effectively removing a broad spectrum of contaminants from wastewater. Topics covered include: fundamental design considerations, flow equalization, headworks components, clarification of raw wastewater, activated sludge, package plants,…
ETV Program Report: Big Fish Septage and High Strength Waste Water Treatment System
Verification testing of the Big Fish Environmental Septage and High Strength Wastewater Processing System for treatment of high-strength wastewater was conducted at the Big Fish facility in Charlevoix, Michigan. Testing was conducted over a 13-month period to address different c...
A PROTOCOL FOR DETERMINING WWF SETTLING VELOCITIES FOR TREATMENT PROCESS DESIGN ENHANCEMENT
Urban wet weather flows (WWF) contain a high proportion of suspended solids (SS) which must be rapidly reduced before release to receiving waters. Site specific, storm-event data evaluations for designing WWF-treatment facilities differs from dry-weather flow design. WWF-sett...
NASA Astrophysics Data System (ADS)
Dittrich, T. M.
2012-12-01
The University of Colorado-Boulder is one of a few universities in the country that has a licensed Treatment, Storage, and Disposal Facility (TSDF) for hazardous waste on campus. This facility, located on the bottom floor of the Environmental Health and Safety (EH&S) building, allows CU to more economically treat hazardous waste by enabling treatment specialists on staff to safely collect and organize the hazardous waste generated on campus. Hazardous waste is anything that contains a regulated chemical or compound and most chemicals used in engineering labs (e.g., acids, solvents, metal solutions) fall into this category. The EH&S staff is able to treat close almost 33% of the waste from campus and the rest is packed for off-site treatment at various places all over the country for disposal (e.g., Sauget, IL, Port Aurthor, TX). The CU-Boulder campus produced over 50 tons of hazardous waste in 2010 costing over $300,000 in off-campus expenses. The EH&S staff assigns one of over 50 codes to the waste which will determine if the waste can be treated on campus of must be shipped off campus to be disposed of. If the waste can be treated on campus, it will undergo one of three processes: 1) neutralization, 2) UV-ozone oxidation, or 3) ion exchange. If the waste is acidic but contains no heavy metals, the acid is neutralized with sodium hydroxide (a base) and can be disposed "down the drain" to the Boulder Wastewater Treatment Plant. If the waste contains organic compounds and no metals, a UV-ozone oxidation system is used to break down the organic compounds. Silver from photography wastewater can be removed using ion exchange columns. Undergraduate and graduate students worked with the hazardous waste treatment facility at the Environmental Health and Safety (EH&S) building on the CU-Boulder campus during the fall of 2011 and fall of 2012. Early in the semester, students receive a tour of the three batch treatment processes the facility is equipped with. Later in the semester, the students conduct a bench-scale laboratory exercise where they study part of the treatment process. Several small start-up companies are testing components in the lab, which adds to the colaboration of the project.; Figure 1. Students in Environmental Water Chemistry lab conducting a titration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-01-01
This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) to assess the potential environmental impacts associated with the construction, operation and decontamination and decommissioning (D&D) of the Waste Segregation Facility (WSF) for the sorting, shredding, and compaction of low-level radioactive waste (LLW) at the Savannah River Site (SRS) located near Aiken, South Carolina. The LLW to be processed consists of two waste streams: legacy waste which is currently stored in E-Area Vaults of SRS and new waste generated from continuing operations. The proposed action is to construct, operate, and D&D a facility to process low-activity job-controlmore » and equipment waste for volume reduction. The LLW would be processed to make more efficient use of low-level waste disposal capacity (E-Area Vaults) or to meet the waste acceptance criteria for treatment at the Consolidated Incineration Facility (CIF) at SRS.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyer, R.S.; Diamante, J.M.; Duffey, R.B.
1996-07-01
The governments of Norway and the US have committed their mutual cooperation and support the Murmansk Shipping Company (MSCo) to expand and upgrade the Low-Level Liquid Radioactive Waste (LLRW) treatment system located at the facilities of the Russian company RTP Atomflot, in Murmansk, Russia. RTP Atomflot provides support services to the Russian icebreaker fleet operated by the MSCo. The objective is to enable Russia to permanently cease disposing of this waste in Arctic waters. The proposed modifications will increase the facility`s capacity from 1,200 m{sup 3} per year to 5,000 m{sup 3} per year, will permit the facility to processmore » high-salt wastes from the Russian Navy`s Northern fleet, and will improve the stabilization and interim storage of the processed wastes. The three countries set up a cooperative review of the evolving design information, conducted by a joint US and Norwegian technical team from April through December, 1995. To ensure that US and Norwegian funds produce a final facility which will meet the objectives, this report documents the design as described by Atomflot and the Russian business organization, ASPECT, both in design documents and orally. During the detailed review process, many questions were generated, and many design details developed which are outlined here. The design is based on the adsorption of radionuclides on selected inorganic resins, and desalination and concentration using electromembranes. The US/Norwegian technical team reviewed the available information and recommended that the construction commence; they also recommended that a monitoring program for facility performance be instituted.« less
The report presents and evaluates the extensive database from the SITE Program demonstration at the MacGillis and Gibbs wood treatment facility in New Brighton, MN. Soil washing and segregation, biotreatment of contaminated process water, and biodegradation of a slurry of the con...
Examples of Disposition Alternatives for WTP Solid Secondary Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seitz, R.
The Hanford Waste Treatment and Immobilization Plant is planned to produce a variety of solid secondary wastes that will require disposal at the Integrated Disposal Facility on the Hanford Site. Solid secondary wastes include a variety of waste streams that are a result of waste treatment and processing activities.
40 CFR 436.31 - Specialized definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and ground water seepage. However, if a mine is also used for treatment of process generated waste... other facility used for treatment of such waste water. The term does not include waste water used for... waste water. (c) The term “10-year 24-hour precipitation event” shall mean the maximum 24 hour...
Renovating existing space to meet special needs for outpatient paediatric oncology.
Rhodes, D A
1999-01-01
Many existing hospital buildings are inadequate to meet needs caused by a tremendous shift from inpatient to outpatient care. Expensive diagnostic and treatment facilities must still be shared by inpatients and outpatients, which in many cases makes renovations to existing facilities on site more appealing than new free-standing facilities; However, care must be taken in the planning and design to make sure that existing hospital operations can be maintained throughout this work. St. Jude Children's Research Hospital in Memphis, an internationally acclaimed institution devoted to the research and treatment of catastrophic illnesses in children has experienced a large growth in its outpatients' care due mainly to changes in treatment modalities and the development of more effective cures. The result has been an extreme overcrowding and unpleasant experiences for patient and family due to awkward patient flow and work processes attempting to respond to the inadequate facility conditions. This paper will not only review the planning issues, but will discuss the renovation which will require several phases in order to minimise disruption to the ongoing activities.
USDA-ARS?s Scientific Manuscript database
The phase out of methyl bromide for the treatment of structures where grain is milled and processed has triggered a need to evaluate the effectiveness of alternative structural treatments such as sulfuryl fluoride and heat. The red flour beetle (Tribolium castaneum (Herbst)) (RFB) and confused flour...
Predictors of Physical Altercation among Adolescents in Residential Substance Abuse Treatment
Crawley, Rachel D.; Becan, Jennifer Edwards; Knight, Danica Kalling; Joe, George W.; Flynn, Patrick M.
2014-01-01
This study tested the hypothesis that basic social information-processing components represented by family conflict, peer aggression, and pro-aggression cognitive scripts are related to aggression and social problems among adolescents in substance abuse treatment. The sample consisted of 547 adolescents in two community-based residential facilities. Correlation results indicated that more peer aggression is related to more pro-aggression scripts; scripts, peer aggression, and family conflict are associated with social problems; and in-treatment physical altercation involvement is predicted by higher peer aggression. Findings suggest that social information-processing components are valuable for treatment research. PMID:26622072
Process wastewater treatability study for Westinghouse fluidized-bed coal gasification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winton, S.L.; Buvinger, B.J.; Evans, J.M.
1983-11-01
In the development of a synthetic fuels facility, water usage and wastewater treatment are major areas of concern. Coal gasification processes generally produce relatively large volumes of gas condensates. These wastewaters are typically composed of a variety of suspended and dissolved organic and inorganic solids and dissolved gaseous contaminants. Fluidized-bed coal gasification (FBG) processes are no exception to this rule. The Department of Energy's Morgantown Energy Technology Center (METC), the Gas Research Institute (GRI), and the Environmental Protection Agency (EPA/IERLRTP) recognized the need for a FBG treatment program to provide process design data for FBG wastewaters during the environmental, health,more » and safety characterization of the Westinghouse Process Development Unit (PDU). In response to this need, METC developed conceptual designs and a program plan to obtain process design and performance data for treating wastewater from commercial-scale Westinghouse-based synfuels plants. As a result of this plan, METC, GRI, and EPA entered into a joint program to develop performance data, design parameters, conceptual designs, and cost estimates for treating wastewaters from a FBG plant. Wastewater from the Westinghouse PDU consists of process quench and gas cooling condensates which are similar to those produced by other FBG processes such as U-Gas, and entrained-bed gasification processes such as Texaco. Therefore, wastewater from this facility was selected as the basis for this study. This paper outlines the current program for developing process design and cost data for the treatment of these wastewaters.« less
Implementing a research utilization plan for prevention of deep vein thrombosis.
Van Wicklin, Sharon A; Ward, Karen S; Cantrell, Shirley W
2006-06-01
Ensuring use of best practices is crucially important in today's health care system. Nurses can identify research results that offer promising new treatment options for their patients and should have a plan for implementing research findings. The perioperative education coordinator at one facility identified the occurrence of deep vein thrombosis as a significant problem. She conducted a literature review, created an education program for nurses, and implemented an evidence-based practice change. This article describes the steps in this process. Now, patients at the facility consistently are assessed for deep vein thrombosis and receive appropriate preventive treatment.
K-Basins Sludge Treatment and Packaging at the Hanford Site - 13585
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fogwell, Thomas W.; Honeyman, James O.; Stegen, Gary
Highly radioactive sludge resulting from the storage of degraded spent nuclear fuel has been consolidated in Engineered Containers (ECs) in the 105-K West Storage Basin located on the Hanford site near the Columbia River in Washington State. CH2M Hill Plateau Remediation Company (CHPRC) is proceeding with a project to retrieve the sludge, place it in Sludge Transport and Storage Containers (STSCs) and store those filled containers within the T Plant Canyon facility on the Hanford Site Central Plateau (Phase 1). Retrieval and transfer of the sludge material will enable removal of the 105-K West Basin and allow remediation of themore » subsurface contamination plumes under the basin. The U.S. Department of Energy (DOE) plans to treat and dispose of this K Basins sludge (Phase 2) as Remote Handled Transuranic Waste (RH TRU) at the Waste Isolation Pilot Plant (WIPP) located in New Mexico. The K Basin sludge currently contains uranium metal which reacts with water present in the stored slurry, generating hydrogen and other byproducts. The established transportation and disposal requirements require the transformation of the K Basins sludge to a chemically stable, liquid-free, packaged waste form. The Treatment and Packaging Project includes removal of the containerised sludge from T Plant, the treatment of the sludge as required, and packaging of all the sludge into a form that is certifiable for transportation to and disposal at WIPP. Completion of this scope will require construction and operation of a Sludge Treatment and Packaging Facility (STPF), which could be either a completely new facility or a modification of an existing Hanford Site facility. A Technology Evaluation and Alternatives Analysis (TEAA) for the STP Phase 2 was completed in 2011. A Request for Technology Information (RFI) had been issued in October 2009 to solicit candidate technologies for use in Phase 2. The RFI also included a preliminary definition of Phase 2 functions and requirements. Potentially applicable technologies were identified through a commercial procurement process, technical workshops, and review of the numerous previous sludge treatment technology studies. The identified technology approaches were screened using the criteria established in the Decision Plan, and focused bench top feasibility testing was conducted. Engineering evaluations of the costs, schedules, and technical maturity were developed and evaluated. Recommendations were developed based on technical evaluations. The criteria used in the evaluation process were as follows: (1) Safety, (2) Regulatory/stakeholder acceptance, (3) Technical maturity, (4) Operability and maintainability, (5) Life cycle cost and schedule, (6) Potential for beneficial integration with ongoing STP-Phase 1 activities, and (7) Integration with Site-wide RH-TRU processing/packaging, planning, schedule, and approach. The TEAA recommended Warm Water Oxidation (WWO) as the baseline treatment technology and two risk reduction enhancement options for further consideration during development of the process - size reduction and chemical oxidation (Fenton's reagent). The enhancement options would potentially allow a useful reduction in the total operating time required to process the K Basins sludge. The U.S. Department of Energy's Richland Field Office (DOE-RL) has approved this recommended technical approach. The baseline process can be broken down into the following main process steps: (1) STSC transfer from T Plant to the Sludge Treatment and Packaging Facility (STPF). (2) Retrieval of sludge from the STSCs and transfer to the Receipt and Reaction Tank (RRT). (3) Preparation for immobilization by oxidation using heated water (i.e., WWO) for those batches that require it and concentration by evaporating water at about atmospheric pressure in the RRT. (4) Immobilization by using additives to eliminate free liquids and packaging of the treated sludge into drums. (5) Inspection and handling of the filled drums prior to transfer to a separate storage and shipping facility. (6) Handling of vapor, condensate, and other waste streams generated by the process. Each of these steps is discussed in the paper, together with the current state of progress in developing the technology and requirements for continued development. A schematic of the recommended baseline WWO treatment process is given below. (authors)« less
Code of Federal Regulations, 2012 CFR
2012-07-01
....111) Owner or operator (§ 63.2) Performance evaluation (§ 63.2) Performance test (§ 63.2) Permitting...) Research and development facility (§ 63.101) Routed to a process or route to a process (§ 63.161) Run (§ 63... vessel (§ 63.161) Temperature monitoring device (§ 63.111) Test method (§ 63.2) Treatment process (§ 63...
40 CFR 63.11140 - Am I subject to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...
40 CFR 63.11140 - Am I subject to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...
40 CFR 63.11140 - Am I subject to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... copolymers production affected source is the facility-wide collection of PVCPU, storage vessels, heat exchange systems, surge control vessels, and wastewater and process wastewater treatment systems that are...
Secondary Waste Form Down-Selection Data Package—Fluidized Bed Steam Reforming Waste Form
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qafoku, Nikolla; Westsik, Joseph H.; Strachan, Denis M.
2011-09-12
The Hanford Site in southeast Washington State has 56 million gallons of radioactive and chemically hazardous wastes stored in 177 underground tanks (ORP 2010). The U.S. Department of Energy (DOE), Office of River Protection (ORP), through its contractors, is constructing the Hanford Tank Waste Treatment and Immobilization Plant (WTP) to convert the radioactive and hazardous wastes into stable glass waste forms for disposal. Within the WTP, the pretreatment facility will receive the retrieved waste from the tank farms and separate it into two treated process streams. These waste streams will be vitrified, and the resulting waste canisters will be sentmore » to offsite (high-level waste [HLW]) and onsite (immobilized low-activity waste [ILAW]) repositories. As part of the pretreatment and ILAW processing, liquid secondary wastes will be generated that will be transferred to the Effluent Treatment Facility (ETF) on the Hanford Site for further treatment. These liquid secondary wastes will be converted to stable solid waste forms that will be disposed of in the Integrated Disposal Facility (IDF). To support the selection of a waste form for the liquid secondary wastes from WTP, Washington River Protection Solutions (WRPS) has initiated secondary waste form testing work at Pacific Northwest National Laboratory (PNNL). In anticipation of a down-selection process for a waste form for the Solidification Treatment Unit to be added to the ETF, PNNL is developing data packages to support that down-selection. The objective of the data packages is to identify, evaluate, and summarize the existing information on the four waste forms being considered for stabilizing and solidifying the liquid secondary wastes. At the Hanford Site, the FBSR process is being evaluated as a supplemental technology for treating and immobilizing Hanford LAW radioactive tank waste and for treating secondary wastes from the WTP pretreatment and LAW vitrification processes.« less
SU-E-T-419: Workflow and FMEA in a New Proton Therapy (PT) Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, C; Wessels, B; Hamilton, H
2014-06-01
Purpose: Workflow is an important component in the operational planning of a new proton facility. By integrating the concept of failure mode and effect analysis (FMEA) and traditional QA requirements, a workflow for a proton therapy treatment course is set up. This workflow serves as the blue print for the planning of computer hardware/software requirements and network flow. A slight modification of the workflow generates a process map(PM) for FMEA and the planning of QA program in PT. Methods: A flowchart is first developed outlining the sequence of processes involved in a PT treatment course. Each process consists of amore » number of sub-processes to encompass a broad scope of treatment and QA procedures. For each subprocess, the personnel involved, the equipment needed and the computer hardware/software as well as network requirements are defined by a team of clinical staff, administrators and IT personnel. Results: Eleven intermediate processes with a total of 70 sub-processes involved in a PT treatment course are identified. The number of sub-processes varies, ranging from 2-12. The sub-processes within each process are used for the operational planning. For example, in the CT-Sim process, there are 12 sub-processes: three involve data entry/retrieval from a record-and-verify system, two controlled by the CT computer, two require department/hospital network, and the other five are setup procedures. IT then decides the number of computers needed and the software and network requirement. By removing the traditional QA procedures from the workflow, a PM is generated for FMEA analysis to design a QA program for PT. Conclusion: Significant efforts are involved in the development of the workflow in a PT treatment course. Our hybrid model of combining FMEA and traditional QA program serves a duo purpose of efficient operational planning and designing of a QA program in PT.« less
Lou, Jie-Chung; Lin, Yung-Chang
2008-02-01
Wastewater reuse can significantly reduce environmental pollution and save the water sources. The study selected Cheng-Ching Lake water treatment plant in southern Taiwan to discuss the feasibility of wastewater recycling and treatment efficiency of wastewater treatment units. The treatment units of this plant include wastewater basin, sedimentation basin, sludge thickener and sludge dewatering facility. In this study, the treatment efficiency of SS and turbidity were 48.35-99.68% and 24.15-99.36%, respectively, showing the significant removal efficiency of the wastewater process. However, the removal efficiencies of NH(3)-N, total organic carbon (TOC) and chemical oxygen demand (COD) are limited by wastewater treatment processes. Because NH(3)-N, TOC and COD of the mixing supernatant and raw water are regulated raw water quality standards, supernatant reuse is feasible and workable during wastewater processes at this plant. Overall, analytical results indicated that supernatant reuse is feasible.
Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA
Karthikeyan, K.G.; Meyer, M.T.
2006-01-01
Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H2O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%) > sulfamethoxazole (70%) > erythromycin-H2O (45%) > ciprofloxacin (40%) > sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (??? 1.3 ??g/L), and importantly were unaffected by the size of the wastewater treatment facility. The concentrations detected were within an order of magnitude of those reported for similar systems in Europe and Canada: they were within a factor of two in comparison to those reported for Canada but generally lower relative to those measured in wastewater systems in Europe. Only sulfamethoxazole and tetracycline were detected in groundwater monitoring wells adjacent to the treatment systems. Future intensive wastewater monitoring programs in Wisconsin may be limited to the six antibiotic compounds detected in this study. ?? 2005 Elsevier B.V. All rights reserved.
Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA.
Karthikeyan, K G; Meyer, Michael T
2006-05-15
Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H(2)O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%)>sulfamethoxazole (70%)>erythromycin-H(2)O (45%)>ciprofloxacin (40%)>sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (
Oxidation Ditch Technology for Upgrading Army Sewage Treatment Facilities.
1983-08-01
expensive and unreliable anaerobic digestion . Because of these advantages, oxidation ditch technology should be considered when planning wastewater...eliminates the need for further sludge treatment (e.g., anaerobic digestion can be eliminated). Does not need primary clarifier. Few moving parts in...four Army plants (see Chapter 2) use the anaerobic digestion process for sludge treatment. There are often problems in operating these digestors, and
Ikehata, Keisuke; Zhao, Yuanyuan; Kulkarni, Harshad; Li, Yuan; Snyder, Shane A; Ishida, Kenneth P; Anderson, Michael A
2018-06-19
Reverse osmosis (RO)-based desalination and advanced water purification facilities have inherent challenges associated with concentrate management and disposal. Although enhanced permeate recovery and concentrate minimization are desired, membrane scaling due to inorganic constituents such as silica, calcium, phosphate, and iron hinders the process. To solve this problem, a new diatom-based photobiological process has been developed to remove these scaling constituents by biological uptake and precipitation. In this study, RO concentrate samples were collected from a full-scale advanced water reclamation facility in California and were treated in 3.8- and 57-L photobioreactors inoculated with a brackish water diatom Pseudostaurosira trainorii PEWL001 using light-emitting diode bulbs or natural sunlight as a light source. The photobiological treatment removed 95% of reactive silica and 64% of calcium and enabled additional water recovery using a secondary RO at a recovery rate up to 66%. This represents 95% overall recovery including 85% recovery in the primary RO unit. In addition to the scaling constituents, the photobiological treatment removed twelve pharmaceuticals and personal care products, as well as N-nitrosodimethylamine, from RO concentrate samples primarily via photolysis. This novel approach has a strong potential for application to brackish water desalination and advanced water purification in arid and semi-arid areas.
NASA Technical Reports Server (NTRS)
Fischer, Holger
2009-01-01
NASA's White Sands Test Facility has six core environmental compliance capabilities: remote hazardous testing of reactive, explosive and toxic materials and fluids; hypergolic fluids materials and systems testing; oxygen materials and system testing; hypervelocity impact testing; flight hardware processing; and, propulsion testing. The facility's permit status and challenges are reviewed. Historic operations and practices dating from the 1960s through the early 1980s resulted in contamination of the facility's groundwater. An environmental restoration effort has been employed to protect public health and the health of the workforce. The restoration seeks to properly handle hazardous materials and waste processes; determine the nature and extent of the contamination; stop the migration of contaminated groundwater; stabilize the plume front which has been assessed as the greatest risk to public health; and, clean-up the environment to restore it to preexisting conditions. The Plume Front Treatment System is operational and seeks to stop the westward movement of the plume to protect drinking water and irrigation well. Specifically, the treatment system will extract contaminated water from the aquifer, remove chemical using the best available technology, and return (inject) the treated water back to the aquifer. The Mid-Plume Interception Treatment System also seeks to stop the migration of containment, as well as to evaluate new technologies to accelerate cleanup, such as bioremediation.
Gedik, Ridvan; Zhang, Shengfan; Rainwater, Chase
2017-06-01
A relatively new consideration in proton therapy planning is the requirement that the mix of patients treated from different categories satisfy desired mix percentages. Deviations from these percentages and their impacts on operational capabilities are of particular interest to healthcare planners. In this study, we investigate intelligent ways of admitting patients to a proton therapy facility that maximize the total expected number of treatment sessions (fractions) delivered to patients in a planning period with stochastic patient arrivals and penalize the deviation from the patient mix restrictions. We propose a Markov Decision Process (MDP) model that provides very useful insights in determining the best patient admission policies in the case of an unexpected opening in the facility (i.e., no-shows, appointment cancellations, etc.). In order to overcome the curse of dimensionality for larger and more realistic instances, we propose an aggregate MDP model that is able to approximate optimal patient admission policies using the worded weight aggregation technique. Our models are applicable to healthcare treatment facilities throughout the United States, but are motivated by collaboration with the University of Florida Proton Therapy Institute (UFPTI).
Jones, Steven M; Chowdhury, Zaid K; Watts, Michael J
2017-03-01
As reuse of municipal water resource recovery facility (WRRF) effluent becomes vital to augment diminishing fresh drinking water resources, concern exists that conventional barriers may prove deficient, and the upcycling of chemicals of emerging concern (CECs) could prove harmful to human health and aquatic species if more effective and robust treatment barriers are not in place. A multiple month survey, of both primary and secondary effluents, from three (3) WRRFs, for 95 CECs was conducted in 2014 to classify CECs by their persistence through conventional water reclamation processes. By sampling the participating WRRF process trains at their peak performance (as determined by measured bulk organics and particulates removal), a short-list of recalcitrant CECs that warrant monitoring to assess treatment performance at advanced water reclamation and production facilities. The list of identified CECs for potable water reclamation (indirect or direct potable reuse) include a herbicide and its degradants, prescription pharmaceuticals and antibiotics, a female hormone, an artificial sweetener, and chlorinated flame retardants. Copyright © 2016 Elsevier Ltd. All rights reserved.
Health Facility Cost of Buruli Ulcer Wound Treatment in Ghana: A Case Study.
Asare, Kofi Hene; Aikins, Moses
2014-09-01
To estimate the wound treatment cost borne by the Buruli Ulcer Treatment Centre of the Amasaman Government Hospital, Ghana. Three different types of data collection approaches were used, namely, 1) observation checklist, 2) in-depth interviews, and 3) expenditure data review. Wound dressing processes were observed. Retrospective health facility cost data of Buruli ulcer (BU) wound treatment for the year 2011 were used. Cost data gathered covered medical and nonmedical items. Cost analyses were carried out to determine the health facility's financial and economic costs. The total annual financial cost was US $121,189.16, of which 99% was recurrent cost. This constitutes about 13% of the expenditure by the Amasaman Government Hospital for the year 2011. The total annual economic cost was US $143,609.22, of which 93% was recurrent cost. The main cost driver for both financial and economic costs was personnel. The annual BU wound treatment costs per capita were US $1615.86 for financial cost and US $1914.79 for economic cost, respectively. The study did not cover household patient costs. The cost of BU wound treatment takes a considerable amount of the hospital's expenditure. This shows the importance of health facility cost as one of the decision-making tools for both resource allocation and mobilization. Hospital management must therefore constantly examine its staffing norms and the associated cost to improve the hospital's resource allocation. Copyright © 2014 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Ratkovic, Branislava; Andrejic, Milan; Vidovic, Milorad
2012-06-01
In 2007, the Serbian Ministry of Health initiated specific activities towards establishing a workable model based on the existing administrative framework, which corresponds to the needs of healthcare waste management throughout Serbia. The objective of this research was to identify the reforms carried out and their outcomes by estimating the efficiencies of a sample of 35 healthcare facilities engaged in the process of collection and treatment of healthcare waste, using data envelopment analysis. Twenty-one (60%) of the 35 healthcare facilities analysed were found to be technically inefficient, with an average level of inefficiency of 13%. This fact indicates deficiencies in the process of collection and treatment of healthcare waste and the information obtained and presented in this paper could be used for further improvement and development of healthcare waste management in Serbia.
A neural network model to predict the wastewater inflow incorporating rainfall events.
El-Din, Ahmed Gamal; Smith, Daniel W
2002-03-01
Under steady-state conditions, a wastewater treatment plant usually has a satisfactory performance because these conditions are similar to design conditions. However, load variations constitute a large portion of the operating life of a treatment facility and most of the observed problems in complying with permit requirements occur during these load transients. During storm events upsets to the different physical and biological processes may take place in a wastewater treatment plant, and therefore, the ability to predict the hydraulic load to a treatment facility during such events is very beneficial for the optimization of the treatment process. Most of the hydrologic and hydraulic models describing sewage collection systems are deterministic. Such models require detailed knowledge of the system and usually rely on a large number of parameters, some of which are uncertain or difficult to determine. Presented in this paper, an artificial neural network (ANN) model that is used to make short-term predictions of wastewater inflow rate that enters the Gold Bar Wastewater Treatment Plant (GBWWTP), the largest plant in the Edmonton area (Alberta, Canada). The neural model uses rainfall data, observed in the collection system discharging to the plant, as inputs. The building process of the model was conducted in a systematic way that allowed the identification of a parsimonious model that is able to learn (and not memorize) from past data and generalize very well to unseen data that was used to validate the model. The neural network model gave excellent results. The potential of using the model as part of a real-time process control system is also discussed.
NASA Astrophysics Data System (ADS)
Myers, Niki; Wessling, Francis; Deuser, Mark; Anderson, C. D.; Lewis, Marian
1999-01-01
The primary goals of the BioDyn program are to foster use of the microgravity environment for commercial production of bio-materials from cells, and to develop services and processes for obtaining these materials through space processing. The scope of products includes commercial bio-molecules such as cytokines, other cell growth regulatory proteins, hormones, monoclonal antibodies and enzymes; transplantable cells or tissues which can be improved by low-G processes, or which cannot be obtained through standard processes in earth gravity; agriculture biotechnology products from plant cells; microencapsulation for diabetes treatment; and factors regulating cellular aging. To facilitate BioDyn's commercial science driven goals, hardware designed for ISS incorporates the flexibility for interchange between the different ISS facilities including the glovebox, various thermal units and centrifuges. By providing a permanent research facility, ISS is the critical space-based platform required by scientists for carrying out the long-term experiments necessary for developing bio-molecules and tissues using several cell culture modalities including suspension and anchorage-dependent cell types.
LIQUID EFFLUENT RETENTION FACILITY (LERF) BASIN 42 STUDIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
DUNCAN JB
2004-10-29
This report documents laboratory results obtained under test plan RPP-21533 for samples submitted by the Effluent Treatment Facility (ETF) from the Liquid Effluent Retention Facility (LERF) Basin 42 (Reference 1). The LERF Basin 42 contains process condensate (PC) from the 242-A Evaporator and landfill leachate. The ETF processes one PC campaign approximately every 12 to 18 months. A typical PC campaign volume can range from 1.5 to 2.5 million gallons. During the September 2003 ETF Basin 42 processing campaign, a recurring problem with 'gelatinous buildup' on the outlet filters from 60A-TK-I (surge tank) was observed (Figure 1). This buildup appearedmore » on the filters after the contents of the surge tank were adjusted to a pH of between 5 and 6 using sulfuric acid. Biological activity in the PC feed was suspected to be the cause of the gelatinous material. Due to this buildup, the filters (10 {micro}m CUNO) required daily change out to maintain process throughput.« less
Steinhardt, Laura C; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek
2014-02-20
Prompt and effective case management is needed to reduce malaria morbidity and mortality. However, malaria diagnosis and treatment is a multistep process that remains problematic in many settings, resulting in missed opportunities for effective treatment as well as overtreatment of patients without malaria. Prior to the widespread roll-out of malaria rapid diagnostic tests (RDTs) in late 2011, a national, cross-sectional, complex-sample, health facility survey was conducted in Malawi to assess patient-, health worker-, and health facility-level factors associated with malaria case management quality using multivariate Poisson regression models. Among the 2,019 patients surveyed, 34% had confirmed malaria defined as presence of fever and parasitaemia on a reference blood smear. Sixty-seven per cent of patients with confirmed malaria were correctly prescribed the first-line anti-malarial, with most cases of incorrect treatment due to missed diagnosis; 31% of patients without confirmed malaria were overtreated with an anti-malarial. More than one-quarter of patients were not assessed for fever or history of fever by health workers. The most important determinants of correct malaria case management were patient-level clinical symptoms, such as spontaneous complaint of fever to health workers, which increased both correct treatment and overtreatment by 72 and 210%, respectively (p<0.0001). Complaint of cough was associated with a 27% decreased likelihood of correct malaria treatment (p=0.001). Lower-level cadres of health workers were more likely to prescribe anti-malarials for patients, increasing the likelihood of both correct treatment and overtreatment, but no other health worker or health facility-level factors were significantly associated with case management quality. Introduction of RDTs holds potential to improve malaria case management in Malawi, but health workers must systematically assess all patients for fever, and then test and treat accordingly, otherwise, malaria control programmes might miss an opportunity to dramatically improve malaria case management, despite better diagnostic tools.
NASA Technical Reports Server (NTRS)
Elden, N. C.; Winkler, H. E.; Price, D. F.; Reysa, R. P.
1983-01-01
Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.
Pillemer, Karl; Meador, Rhoda; Henderson, Charles; Robison, Julie; Hegeman, Carol; Graham, Edwin; Schultz, Leslie
2008-07-01
This article reports on a randomized, controlled intervention study designed to reduce employee turnover by creating a retention specialist position in nursing homes. We collected data three times over a 1-year period in 30 nursing homes, sampled in stratified random manner from facilities in New York State and Connecticut and randomly assigned to treatment and control conditions. Staff outcomes were measured through certified nursing assistant interviews, and turnover rates were measured over the course of the year. In the intervention condition, a staff member was selected to be the facility retention specialist, who would advocate for and implement programs to improve staff retention and commitment throughout the facility. Retention specialists received an intensive 3-day training in retention leadership and in a number of evidence-based retention programs. Ongoing support was provided throughout the project. Treatment facilities experienced significant declines in turnover rates compared to control facilities. As predicted, we found positive effects on certified nursing assistant assessments of the quality of retention efforts and of care provided in the facility; we did not find effects for job satisfaction or stress. The study provides evidence for the effectiveness of the retention specialist model. Findings from a detailed process evaluation suggest modifications of the program that may increase program effects.
Alvarez, R; Ordóñez, A; Loredo, J; Younger, P L
2013-10-01
Gold extraction operations generate a variety of wastes requiring responsible disposal in compliance with current environmental regulations. During recent decades, increased emphasis has been placed on effluent control and treatment, in order to avoid the threat to the environment posed by toxic constituents. In many modern gold mining and ore processing operations, cyanide species are of most immediate concern. Given that natural degradation processes are known to reduce the toxicity of cyanide over time, trials have been made at laboratory and field scales into the feasibility of using wetland-based passive systems as low-cost and environmentally friendly methods for long-term treatment of leachates from closed gold mine tailing disposal facilities. Laboratory experiments on discrete aerobic and anaerobic treatment units supported the development of design parameters for the construction of a field-scale passive system at a gold mine site in northern Spain. An in situ pilot-scale wetland treatment system was designed, constructed and monitored over a nine-month period. Overall, the results suggest that compost-based constructed wetlands are capable of detoxifying cyanidation effluents, removing about 21.6% of dissolved cyanide and 98% of Cu, as well as nitrite and nitrate. Wetland-based passive systems can therefore be considered as a viable technology for removal of residual concentrations of cyanide from leachates emanating from closed gold mine tailing disposal facilities.
Systematic Review of Multidisciplinary Chronic Pain Treatment Facilities
Fashler, Samantha R.; Cooper, Lynn K.; Oosenbrug, Eric D.; Burns, Lindsay C.; Razavi, Shima; Goldberg, Lauren; Katz, Joel
2016-01-01
This study reviewed the published literature evaluating multidisciplinary chronic pain treatment facilities to provide an overview of their availability, caseload, wait times, and facility characteristics. A systematic literature review was conducted using PRISMA guidelines following a search of MEDLINE, PsycINFO, and CINAHL databases. Inclusion criteria stipulated that studies be original research, survey more than one pain treatment facility directly, and describe a range of available treatments. Fourteen articles satisfied inclusion criteria. Results showed little consistency in the research design used to describe pain treatment facilities. Availability of pain treatment facilities was scarce and the reported caseloads and wait times were generally high. A wide range of medical, physical, and psychological pain treatments were available. Most studies reported findings on the percentage of practitioners in different health care professions employed. Future studies should consider using more comprehensive search strategies to survey facilities, improving clarity on what is considered to be a pain treatment facility, and reporting on a consistent set of variables to provide a clear summary of the status of pain treatment facilities. This review highlights important information for policymakers on the scope, demand, and accessibility of pain treatment facilities. PMID:27445618
Vilasdechanon, N; Ua-Apisitwong, S; Chatnampet, K; Ekmahachai, M; Vilasdechanon, J
2014-09-01
The great benefit of (131)I radionuclide treatment for differentiated thyroid cancer (DTC) was acknowledged by the long survival rate. The main requirements for (131)I therapy in hospital were treatment facilities and a radiation safety plan that assured radiation protection and safety to patient, hospital worker, public, and environment. To introduce the concepts and methods of radiation safety design for a patient's room in a (131)I treatment ward and a system of radioactive waste water management in hospital. The design was based on principles of external and internal radiation protection for unsealed source and radioactive waste management. Planning for treatment facilities was concluded from clinical evidence, physical and physiological information for (131)I, radiation safety criteria, hospital resources and budget. The three phases of the working process were: construction, software development, and radiation safety assessment. The (131)I treatment facility and automatic radioactive waste water management system was completely implemented in 2009. The radiation waste water management system known as the 'Suandok Model' was highly recommended by the national regulator to hospitals who desire to provide (131)I treatment for thyroid cancer. In 2011, the Nuclear Medicine Division, Chiang Mai University was rewarded by the national authority for a very good radiation practice in development of safe working conditions and environment. The Suandok Model was a facility design that fulfilled requirements for the safe use of high radiation (131)I doses for thyroid cancer treatment in hospital. The facility presented in this study may not be suitable for all hospitals but the design concepts could be applied according to an individual hospital context and resources. People who use or gain benefit from radiation applications have to emphasise the responsibility to control and monitor radiation effects on individuals, communities and the environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becthel Jacobs Company LLC
2002-11-01
The Y-12 National Security Complex (Y-12 Complex) is an active manufacturing and developmental engineering facility that is located on the U.S. Department of Energy (DOE) Oak Ridge Reservation. Building 9201-2 was one of the first process buildings constructed at the Y-12 Complex. Construction involved relocating and straightening of the Upper East Fork Poplar Creek (UEFPC) channel, adding large quantities of fill material to level areas along the creek, and pumping of concrete into sinkholes and solution cavities present within the limestone bedrock. Flow from a large natural spring designated as ''Big Spring'' on the original 1943 Stone & Webster Buildingmore » 9201-2 Field Sketch FS6003 was captured and directed to UEFPC through a drainpipe designated Outfall 51. The building was used from 1953 to 1955 for pilot plant operations for an industrial process that involved the use of large quantities of elemental mercury. Past operations at the Y-12 Complex led to the release of mercury to the environment. Significant environmental media at the site were contaminated by accidental releases of mercury from the building process facilities piping and sumps associated with Y-12 Complex mercury handling facilities. Releases to the soil surrounding the buildings have resulted in significant levels of mercury in these areas of contamination, which is ultimately transported to UEFPC, its streambed, and off-site. Bechtel Jacobs Company LLC (BJC) is the DOE-Oak Ridge Operations prime contractor responsible for conducting environmental restoration activities at the Y-12 Complex. In order to mitigate the mercury being released to UEFPC, the Big Spring Water Treatment System will be designed and constructed as a Comprehensive Environmental Response, Compensation, and Liability Act action. This facility will treat the combined flow from Big Spring feeding Outfall 51 and the inflow now being processed at the East End Mercury Treatment System (EEMTS). Both discharge to UEFPC adjacent to Bldg. 9201-2. The EEMTS treats mercury-contaminated groundwater that collects in sumps in the basement of Bldg. 9201-2. A pre-design study was performed to investigate the applicability of various treatment technologies for reducing mercury discharges at Outfall 51 in support of the design of the Big Spring Water Treatment System. This document evaluates the results of the pre-design study for selection of the mercury removal technology for the treatment system.« less
Krauter, Paula; Edwards, Donna; Yang, Lynn; Tucker, Mark
2011-09-01
Decontamination and recovery of a facility or outdoor area after a wide-area biological incident involving a highly persistent agent (eg, Bacillus anthracis spores) is a complex process that requires extensive information and significant resources, which are likely to be limited, particularly if multiple facilities or areas are affected. This article proposes a systematic methodology for evaluating information to select the decontamination or alternative treatments that optimize use of resources if decontamination is required for the facility or area. The methodology covers a wide range of approaches, including volumetric and surface decontamination, monitored natural attenuation, and seal and abandon strategies. A proposed trade-off analysis can help decision makers understand the relative appropriateness, efficacy, and labor, skill, and cost requirements of the various decontamination methods for the particular facility or area needing treatment--whether alone or as part of a larger decontamination effort. Because the state of decontamination knowledge and technology continues to evolve rapidly, the methodology presented here is designed to accommodate new strategies and materials and changing information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, T.E.
1993-10-01
The Federal Facilities Compliance Act (the Act) of 1992 waives sovereign immunity for federal facilities for fines and penalties under the provisions of the Resource Recovery and Conservation Act, state, interstate, and local hazardous and solid waste management requirements. However, for three years the Act delays the waiver for violations involving US Department of Energy (DOE) facilities. The Act, however, requires that the DOE prepare a Conceptual Site Treatment Plan (CSTP) for each of its sites that generate or store mixed wastes (MWs). The purpose of the CSTP is to present DOE`s preliminary evaluations of the development of treatment capacitiesmore » and technologies for treating a site`s MW. This CSTP presents the preliminary capacity and technology evaluation for the Laboratory for Energy-Related Health Research (LEHR). The five identified MW streams at LEHR are evaluated to the extent possible given available information. Only one MW stream is sufficiently well defined to permit a technology evaluation to be performed. Two other MW streams are in the process of being characterized so that an evaluation can be performed. The other two MW streams will be generated by the decommissioning of inactive facilities onsite within the next five years.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Del Cul, G.D.
1991-02-01
The Paducah Gaseous Diffusion Plant C-400 Decontamination Facility generators aqueous solutions that originate in drum washing, machine parts and equipment cleaning, and other decontamination processes. In general, the waste contains uranyl, fluoride, carbonate, and nitrate ions, in addition to soaps, detergents, secondary contaminants, and particulate matter. The main contaminants are fluoride, technetium, uranium, and other heavy metals. In accordance with Department of Energy (DOE) Order 5400.5, the releases of radioactive materials must be as low as reasonably achievable and be below the derived concentration guide limits. To comply with the DOE order, an action plan was formulated. The action planmore » included a literature search to support best available technology evaluation of treatment alternatives, a quality assurance/quality control plan, suggestion of alternative treatment options, bench-scale test studies of the proposed treatment alternatives, and establishment of the final recommendation. Five major technologies were considered: precipitation/coprecipitation, reverse osmosis, ultrafiltration, supported liquid membranes, and ion exchange. Biosorption was also briefly considered. Based on C-400's requirements and facilities, the precipitation/coprecipitation process appears to be the best suited for use at the plant. Four different treatment options using the precipitation/coprecipitation technology were proposed. Bench-scale studies of all four options were suggested. Options 1 and 2 represent a combination of lime-softening and iron coprecipitation. Laboratory test evaluations were initiated and the results involving Options 1 and 2 reported here. 29 refs., 1 fig., 2 tabs.« less
Technological Aspects of Waterworks Sludge Treatment
NASA Astrophysics Data System (ADS)
Belkanova, M. Yu; Nikolaenko, E. V.; Gevel, D. A.
2017-11-01
The water yielding capacity of the sludge in water-supply network treatment facilities is determined by the water quality in a water source and its treatment technology. The paper studies the sludge of water-supply network treatment facilities formed in the conditions of low turbidity and average water colour index in the water source. Such sludge has a low water yielding capacity and is subject to conditioning. The paper shows the influence of seasonal variations of turbidity, water colour index and temperature of the feed water on the specific sludge filtration resistance. It considers the specific features of sludge formation in different settling basins influencing its water yielding capacity. It is shown that the washwater return performed at one of the blocks of the facilities increases the feed water turbidity and leads to the formation of the sludge easily susceptible to conditioning. The paper studies the following methods of the reagent sludge treatment: polyacrylamide-based flocculant treatment, joint treatment with flocculant and vermiculite filler, lime treatment. The use of vermiculite allows to reduce the required flocculant dose. The author determines optimum doses of reagents allowing to direct the sludge for further mechanical dewatering after conditioning. It is shown that, when the sludge is processed with lime, the filtrate formed at dewatering can be reused as an alkalifying agent, which will allow one to cut the costs for the acquisition of reagents.
Application of electric corona discharge for grain seeds treatment before sowing
NASA Astrophysics Data System (ADS)
Porsev, E. G.; Malozyomov, B. V.; Rozhkova, M. V.
2017-10-01
The paper overviews directions for electrotechnology treatment of grain seeds before sowing. The hypothesis of the germination enhancement of seeds if treated with corona discharge is presented here. Besides, the description of electrotechnology installation and facilities for it including manufacturing process quality obtained as a result of scientific tests are also provided in the paper.
NASA Astrophysics Data System (ADS)
Markelov, A. Y.; Shiryaevskii, V. L.; Kudrinskiy, A. A.; Anpilov, S. V.; Bobrakov, A. N.
2017-11-01
A computational method of analysis of physical and chemical processes of high-temperature mineralizing of low-level radioactive waste in gas stream in the process of plasma treatment of radioactive waste in shaft furnaces was introduced. It was shown that the thermodynamic simulation method allows fairly adequately describing the changes in the composition of the pyrogas withdrawn from the shaft furnace at different waste treatment regimes. This offers a possibility of developing environmentally and economically viable technologies and small-sized low-cost facilities for plasma treatment of radioactive waste to be applied at currently operating nuclear power plants.
Mori, Shinichiro; Inaniwa, Taku; Kumagai, Motoki; Kuwae, Tsunekazu; Matsuzaki, Yuka; Furukawa, Takuji; Shirai, Toshiyuki; Noda, Koji
2012-06-01
To increase the accuracy of carbon ion beam scanning therapy, we have developed a graphical user interface-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the X-ray projection ray. Since we implemented graphics processing unit-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.
75 FR 4227 - Phytosanitary Treatments; Location of and Process for Updating Treatment Schedules
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-26
...We are amending the phytosanitary treatment regulations in 7 CFR part 305 by removing the lists of approved treatments and treatment schedules from the regulations, while retaining the general requirements for performing treatments and certifying or approving treatment facilities. We are removing treatment schedules from other places where they are currently found in 7 CFR chapter III as well. Approved treatment schedules will instead be found in the Plant Protection and Quarantine Treatment Manual, which is available on the Internet. We are also establishing a new process to provide the public with notice and the opportunity to comment on changes to treatment schedules. Finally, we are harmonizing and combining the requirements for performing irradiation treatment for imported articles, articles moved interstate from Hawaii and U.S. territories, and articles moved interstate from an area quarantined for fruit flies. These changes will simplify and expedite our processes for adding, changing, and removing treatment schedules while continuing to provide for public participation in the process. These changes will also simplify our presentation of treatments to the public by consolidating all treatments into one document and eliminating redundant text from the regulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nero, A.V.; Quinby-Hunt, M.S.
1977-01-01
This report sets forth methodologies for review of the health and safety aspects of proposed nuclear, geothermal, and fossil-fuel sites and facilities for electric power generation. The review is divided into a Notice of Intention process and an Application for Certification process, in accordance with the structure to be used by the California Energy Resources Conservation and Development Commission, the first emphasizing site-specific considerations, the second examining the detailed facility design as well. The Notice of Intention review is divided into three possible stages: an examination of emissions and site characteristics, a basic impact analysis, and an assessment of publicmore » impacts. The Application for Certification review is divided into five possible stages: a review of the Notice of Intention treatment, review of the emission control equipment, review of the safety design, review of the general facility design, and an overall assessment of site and facility acceptability.« less
Graham, Jennifer L.; Stone, Mandy L.; Rasmussen, Teresa J.; Poulton, Barry C.
2010-01-01
The Johnson County Blue River Main Wastewater Treatment Facility discharges into the upper Blue River near the border between Johnson County, Kansas and Jackson County, Missouri. During 2005 through 2007 the wastewater treatment facility underwent upgrades to increase capacity and include biological nutrient removal. The effects of wastewater effluent on environmental and biological conditions of the upper Blue River were assessed by comparing an upstream site to two sites located downstream from the wastewater treatment facility. Environmental conditions were evaluated using previously and newly collected discrete and continuous data, and were compared with an assessment of biological community composition and ecosystem function along the upstream-downstream gradient. This evaluation is useful for understanding the potential effects of wastewater effluent on water quality, biological community structure, and ecosystem function. In addition, this information can be used to help achieve National Pollution Discharge Elimination System (NPDES) wastewater effluent permit requirements after additional studies are conducted. The effects of wastewater effluent on the water-quality conditions of the upper Blue River were most evident during below-normal and normal streamflows (about 75 percent of the time), when wastewater effluent contributed more than 20 percent to total streamflow. The largest difference in water-quality conditions between the upstream and downstream sites was in nutrient concentrations. Total and inorganic nutrient concentrations at the downstream sites during below-normal and normal streamflows were 4 to 15 times larger than at the upstream site, even after upgrades to the wastewater treatment facility were completed. However, total nitrogen concentrations decreased in wastewater effluent and at the downstream site following wastewater treatment facility upgrades. Similar decreases in total phosphorus were not observed, likely because the biological phosphorus removal process was not optimized until after the study was completed. Total nitrogen and phosphorus from the wastewater treatment facility contributed a relatively small percentage (14 to 15 percent) to the annual nutrient load in the upper Blue River, but contributed substantially (as much as 75 percent) to monthly loads during seasonal low-flows in winter and summer. During 2007 and 2008, annual discharge from the wastewater treatment facility was about one-half maximum capacity, and estimated potential maximum annual loads were 1.6 to 2.4 times greater than annual loads before capacity upgrades. Even when target nutrient concentrations are met, annual nutrient loads will increase when the wastewater treatment facility is operated at full capacity. Regardless of changes in annual nutrient loads, the reduction of nutrient concentrations in the Blue River Main wastewater effluent will help prevent further degradation of the upper Blue River. The Blue River Main Wastewater Treatment Facility wastewater effluent caused changes in concentrations of several water-quality constituents that may affect biological community structure and function including larger concentrations of bioavailable nutrients (nitrate and orthophosphorus) and smaller turbidities. Streambed-sediment conditions were similar along the upstream-downstream gradient and measured constituents did not exceed probable effect concentrations. Habitat conditions declined along the upstream-downstream gradient, largely because of decreased canopy cover and riparian buffer width and increased riffle-substrate fouling. Algal biomass, primary production, and the abundance of nutrient-tolerant diatoms substantially increased downstream from the wastewater treatment facility. Likewise, the abundance of intolerant macroinvertebrate taxa and Kansas Department of Health and Environment aquatic-life-support scores, derived from macroinvertebrate data, significantly decreased downstream from the wastewater
SECONDARY WASTE/ETF (EFFLUENT TREATMENT FACILITY) PRELIMINARY PRE-CONCEPTUAL ENGINEERING STUDY
DOE Office of Scientific and Technical Information (OSTI.GOV)
MAY TH; GEHNER PD; STEGEN GARY
2009-12-28
This pre-conceptual engineering study is intended to assist in supporting the critical decision (CD) 0 milestone by providing a basis for the justification of mission need (JMN) for the handling and disposal of liquid effluents. The ETF baseline strategy, to accommodate (WTP) requirements, calls for a solidification treatment unit (STU) to be added to the ETF to provide the needed additional processing capability. This STU is to process the ETF evaporator concentrate into a cement-based waste form. The cementitious waste will be cast into blocks for curing, storage, and disposal. Tis pre-conceptual engineering study explores this baseline strategy, in additionmore » to other potential alternatives, for meeting the ETF future mission needs. Within each reviewed case study, a technical and facility description is outlined, along with a preliminary cost analysis and the associated risks and benefits.« less
Economic viability of anaerobic digestion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wellinger, A.
1996-01-01
The industrial application of anaerobic digestion is a relatively new, yet proven waste treatment technology. Anaerobic digestion reduces and upgrades organic waste, and is a good way to control air pollution as it reduces methane and nitrous gas emissions. For environmental and energy considerations, anaerobic digestion is a nearly perfect waste treatment process. However, its economic viability is still in question. A number of parameters - type of waste (solid or liquid), digester system, facility size, product quality and end use, environmental requirements, cost of alternative treatments (including labor), and interest rates - define the investment and operating costs ofmore » an anaerobic digestion facility. Therefore, identical facilities that treat the same amount and type of waste may, depending on location, legislation, and end product characteristics, reveal radically different costs. A good approach for evaluating the economics of anaerobic digestion is to compare it to treatment techniques such as aeration or conventional sewage treatment (for industrial wastewater), or composting and incineration (for solid organic waste). For example, the cost (per ton of waste) of in-vessel composting with biofilters is somewhat higher than that of anaerobic digestion, but the investment costs 1 1/2 to 2 times more than either composting or anaerobic digestion. Two distinct advantages of anaerobic digestion are: (1) it requires less land than either composting or incinerating, which translates into lower costs and milder environmental and community impacts (especially in densely populated areas); and (2) it produces net energy, which can be used to operate the facility or sold to nearby industries.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, Ben C.; Heacker, Fred K.; Shannon, Christopher
2013-07-01
The U.S. Department of Energy (DOE) needs to safely and efficiently treat its 'legacy' transuranic (TRU) waste and mixed low-level waste (LLW) from past research and defense activities at the Oak Ridge National Laboratory (ORNL) so that the waste is prepared for safe and secure disposal. The TWPC operates an Environmental Management (EM) waste processing facility on the Oak Ridge Reservation (ORR). The TWPC is classified as a Hazard Category 2, non-reactor nuclear facility. This facility receives, treats, and packages low-level waste and TRU waste stored at various facilities on the ORR for eventual off-site disposal at various DOE sitesmore » and commercial facilities. The Remote Handled TRU Waste Sludge held in the Melton Valley Storage Tanks (MVSTs) was produced as a result of the collection, treatment, and storage of liquid radioactive waste originating from the ORNL radiochemical processing and radioisotope production programs. The MVSTs contain most of the associated waste from the Gunite and Associated Tanks (GAAT) in the ORNL's Tank Farms in Bethel Valley and the sludge (SL) and associated waste from the Old Hydro-fracture Facility tanks and other Federal Facility Agreement (FFA) tanks. The SL Processing Facility Build-outs (SL-PFB) Project is integral to the EM cleanup mission at ORNL and is being accelerated by DOE to meet updated regulatory commitments in the Site Treatment Plan. To meet these commitments a Baseline (BL) Change Proposal (BCP) is being submitted to provide continued spending authority as the project re-initiation extends across fiscal year 2012 (FY2012) into fiscal year 2013. Future waste from the ORNL Building 3019 U-233 Disposition project, in the form of U-233 dissolved in nitric acid and water, down-blended with depleted uranyl nitrate solution is also expected to be transferred to the 7856 MVST Annex Facility (formally the Capacity Increase Project (CIP) Tanks) for co-processing with the SL. The SL-PFB project will construct and install the necessary integrated systems to process the accumulated MVST Facilities SL inventory at the TWPC thus enabling safe and effective disposal of the waste. This BCP does not include work to support current MVST Facility Surveillance and Maintenance programs or the ORNL Building 3019 U-233 Disposition project, since they are not currently part of the TWPC prime contract. The purpose of the environmental compliance strategy is to identify the environmental permits and other required regulatory documents necessary for the construction and operation of the SL- PFB at the TWPC, Oak Ridge, TN. The permits and other regulatory documents identified are necessary to comply with the environmental laws and regulations of DOE Orders, and other requirements documented in the SL-PFB, Safety Design Strategy (SDS), SL-A-AD-002, R0 draft, and the Systems, Function and Requirements Document (SFRD), SL-X-AD-002, R1 draft. This compliance strategy is considered a 'living strategy' and it is anticipated that it will be revised as design progresses and more detail is known. The design basis on which this environmental permitting and compliance strategy is based is the Wastren Advantage, Inc., (WAI), TWPC, SL-PFB (WAI-BL-B.01.06) baseline. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasser, K.
1994-06-01
In FY 1993, the Los Alamos National Laboratory Waste Management Group [CST-7 (formerly EM-7)] requested the Probabilistic Risk and Hazards Analysis Group [TSA-11 (formerly N-6)] to conduct a study of the hazards associated with several CST-7 facilities. Among these facilities are the Hazardous Waste Treatment Facility (HWTF), the HWTF Drum Storage Building (DSB), and the Mixed Waste Receiving and Storage Facility (MWRSF), which are proposed for construction beginning in 1996. These facilities are needed to upgrade the Laboratory`s storage capability for hazardous and mixed wastes and to provide treatment capabilities for wastes in cases where offsite treatment is not availablemore » or desirable. These facilities will assist Los Alamos in complying with federal and state requlations.« less
Current Capabilities and Capacity of Ebola Treatment Centers in the United States.
Herstein, Jocelyn J; Biddinger, Paul D; Kraft, Colleen S; Saiman, Lisa; Gibbs, Shawn G; Le, Aurora B; Smith, Philip W; Hewlett, Angela L; Lowe, John J
2016-03-01
To describe current Ebola treatment center (ETC) locations, their capacity to care for Ebola virus disease patients, and infection control infrastructure features. A 19-question survey was distributed electronically in April 2015. Responses were collected via email by June 2015 and analyzed in an electronic spreadsheet. The survey was sent to and completed by site representatives of each ETC. The survey was sent to all 55 ETCs; 47 (85%) responded. Of the 47 responding ETCs, there are 84 isolation beds available for adults and 91 for children; of these pediatric beds, 35 (38%) are in children's hospitals. In total, the simultaneous capacity of the 47 reporting ETCs is 121 beds. On the basis of the current US census, there are 0.38 beds per million population. Most ETCs have negative pressure isolation rooms, anterooms, and a process for category A waste sterilization, although only 11 facilities (23%) have the capability to sterilize infectious waste on site. Facilities developed ETCs on the basis of Centers for Disease Control and Prevention guidance, but specific capabilities are not mandated at this present time. Owing to the complex and costly nature of Ebola virus disease treatment and variability in capabilities from facility to facility, in conjunction with the lack of regulations, nationwide capacity in specialized facilities is limited. Further assessments should determine whether ETCs can adapt to safely manage other highly infectious disease threats.
Evaluation of the Hanford 200 West Groundwater Treatment System: Fluidized Bed Bioreactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Looney, Brian B.; Jackson, Dennis G.; Dickson, John O.
A fluidized bed reactor (FBR) in the 200W water treatment facility at Hanford is removing nitrate from groundwater as part of the overall pump-treat-reinject process. Control of the FBR bed solids has proven challenging, impacting equipment, increasing operations and maintenance (O&M), and limiting the throughput of the facility. In response to the operational challenges, the Department of Energy Richland Office (DOE-RL) commissioned a technical assistance team to facilitate a system engineering evaluation and provide focused support recommendations to the Hanford Team. The DOE Environmental Management (EM) technical assistance process is structured to identify and triage technologies and strategies that addressmore » the target problem(s). The process encourages brainstorming and dialog and allows rapid identification and prioritization of possible options. Recognizing that continuous operation of a large-scale FBR is complex, requiring careful attention to system monitoring data and changing conditions, the technical assistance process focused on explicit identification of the available control parameters (“knobs”), how these parameters interact and impact the FBR system, and how these can be adjusted under different scenarios to achieve operational goals. The technical assistance triage process was performed in collaboration with the Hanford team.« less
Wu, Duo; Zhang, Chunyan; Lü, Fan; Shao, Liming; He, Pinjing
2014-06-01
The application of on-site waste treatment significantly reduces the need for expensive waste collection and transportation in rural areas; hence, it is considered of fundamental importance in developing countries. In this study, the effects of in-field operation of two types of mini-scale on-site solid waste treatment facilities on de-centralized communities, one using mesophilic two-phase anaerobic digestion combined with composting (TPAD, 50 kg/d) and another using decentralized composting (DC, 0.6-2 t/d), were investigated. Source-separated collection was applied to provide organic waste for combined process, in which the amount of waste showed significant seasonal variation. The highest collection amount was 0.18 kg/capital day and 0.6 kg/household day. Both sites showed good performance after operating for more than 6 months, with peak waste reduction rates of 53.5% in TPAD process and 63.2% in DC process. Additionally, the windrow temperature exceeded 55 °C for >5 days, indicating that the composting products from both facilities were safe. These results were supported by 4 days aerobic static respiration rate tests. The emissions were low enough to avoid any impact on nearby communities (distance <100 m). Partial energy could be recovered by the combined process but with complicated operation. Hence, the choice of process must be considered in case separately. Copyright © 2013 Elsevier Ltd. All rights reserved.
Brown Grease to Biodiesel Demonstration Project Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
San Francisco Public Utilities Commission; URS Corporation; Biofuels, Blackgold
Municipal wastewater treatment facilities have typically been limited to the role of accepting wastewater, treating it to required levels, and disposing of its treatment residuals. However, a new view is emerging which includes wastewater treatment facilities as regional resource recovery centers. This view is a direct result of increasingly stringent regulations, concerns over energy use, carbon footprint, and worldwide depletion of fossil fuel resources. Resources in wastewater include chemical and thermal energy, as well as nutrients, and water. A waste stream such as residual grease, which concentrates in the drainage from restaurants (referred to as Trap Waste), is a goodmore » example of a resource with an energy content that can be recovered for beneficial reuse. If left in wastewater, grease accumulates inside of the wastewater collection system and can lead to increased corrosion and pipe blockages that can cause wastewater overflows. Also, grease in wastewater that arrives at the treatment facility can impair the operation of preliminary treatment equipment and is only partly removed in the primary treatment process. In addition, residual grease increases the demand in treatment materials such as oxygen in the secondary treatment process. When disposed of in landfills, grease is likely to undergo anaerobic decay prior to landfill capping, resulting in the atmospheric release of methane, a greenhouse gas (GHG). This research project was therefore conceptualized and implemented by the San Francisco Public Utilities Commission (SFPUC) to test the feasibility of energy recovery from Trap Waste in the form of Biodiesel or Methane gas. The research goals are given below: To validate technology performance; To determine the costs and benefits [including economic, socioeconomic, and GHG emissions reduction] associated with co-locating this type of operation at a municipal wastewater treatment plant (WWTP); To develop a business case or model for replication of the program by other municipal agencies (as applicable). In order to accomplish the goals of the project, the following steps were performed: 1. Operation of a demonstration facility designed to receive 10,000 to 12,000 gallons of raw Trap Waste each day from private Trap Waste hauling companies. The demonstration facility was designed and built by Pacific Biodiesel Technologies (PBTech). The demonstration facility would also recover 300 gallons of Brown Grease per day from the raw Trap Waste. The recovered Brown Grease was expected to contain no more than 2% Moisture, Insolubles, and Unsaponifiables (MIU) combined. 2. Co-digestion of the side streams (generated during the recovery of 300 gallons of Brown Grease from the raw Trap Waste) with wastewater sludge in the WWTP's anaerobic digesters. The effects of the side streams on anaerobic digestion were quantified by comparison with baseline data. 3. Production of 240 gallons per day of ASTM D6751-S15 grade Biodiesel fuel via a Biodiesel conversion demonstration facility, with the use of recovered Brown Grease as a feedstock. The demonstration facility was designed and built by Blackgold Biofuels (BGB). Side streams from this process were also co-digested with wastewater sludge. Bench-scale anaerobic digestion testing was conducted on side streams from both demonstration facilities to determine potential toxicity and/or changes in biogas production in the WWTP anaerobic digester. While there is a lot of theoretical data available on the lab-scale production of Biodiesel from grease Trap Waste, this full-scale demonstration project was one of the first of its kind in the United States. The project's environmental impacts were expected to include: Reduction of greenhouse gas emissions by prevention of the release of methane at landfills. Although the combustion product of Biodiesel and Methane gas produced in the Anaerobic digester, Carbon Dioxide, is also a greenhouse gas; it is 20 times weaker for the same amount (per mole) released, making its discharge preferable to that of Methane. The use of Biodiesel in place of fossil-fuel derived Diesel was expected to reduce net Carbon Dioxide, Ash Particulate, Sulfate, Silicate, and Soot emissions, thereby improving air quality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mackey, H.E. Jr.
1979-01-01
A review of the literature indicates that a significant body of descriptive information exists concerning the aquatic ecology of Upper Three Runs Creek and Four Mile Creek of the Savannah River Plant south of Aiken, South Carolina. This information is adequate for preparation of an environmental document evaluating these streams. These streams will be impacted by construction and operation of a proposed Defense Waste Processing Facility for solidification of high level defense waste. Potential impacts include (1) construction runoff, erosion, and siltation, (2) effluents from a chemical and industrial waste treatment facility, and (3) radionuclide releases. In order to bettermore » evaluate potential impacts, recommend mitigation methods, and comply with NEPA requirements, additional quantitative biological information should be obtained through implementation of an aquatic baseline program.« less
Pathways for Disposal of Commercially-Generated Tritiated Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halverson, Nancy V.
From a waste disposal standpoint, tritium is a major challenge. Because it behaves like hydrogen, tritium exchanges readily with hydrogen in the ground water and moves easily through the ground. Land disposal sites must control the tritium activity and mobility of incoming wastes to protect human health and the environment. Consequently, disposal of tritiated low-level wastes is highly regulated and disposal options are limited. The United States has had eight operating commercial facilities licensed for low-level radioactive waste disposal, only four of which are currently receiving waste. Each of these is licensed and regulated by its state. Only two ofmore » these sites accept waste from states outside of their specified regional compact. For waste streams that cannot be disposed directly at one of the four active commercial low-level waste disposal facilities, processing facilities offer various forms of tritiated low-level waste processing and treatment, and then transport and dispose of the residuals at a disposal facility. These processing facilities may remove and recycle tritium, reduce waste volume, solidify liquid waste, remove hazardous constituents, or perform a number of additional treatments. Waste brokers also offer many low-level and mixed waste management and transportation services. These services can be especially helpful for small-quantity tritiated-waste generators, such as universities, research institutions, medical facilities, and some industries. The information contained in this report covers general capabilities and requirements for the various disposal/processing facilities and brokerage companies, but is not considered exhaustive. Typically, each facility has extensive waste acceptance criteria and will require a generator to thoroughly characterize their wastes. Then a contractual agreement between the waste generator and the disposal/processing/broker entity must be in place before waste is accepted. Costs for tritiated waste transportation, processing and disposal vary based a number of factors. In many cases, wastes with very low radioactivity are priced primarily based on weight or volume. For higher activities, costs are based on both volume and activity, with the activity-based charges usually being much larger than volume-based charges. Other factors affecting cost include location, waste classification and form, other hazards in the waste, etc. Costs may be based on general guidelines used by an individual disposal or processing site, but final costs are established by specific contract with each generator. For this report, seven hypothetical waste streams intended to represent commercially-generated tritiated waste were defined in order to calculate comparative costs. Ballpark costs for disposition of these hypothetical waste streams were calculated. These costs ranged from thousands to millions of dollars. Due to the complexity of the cost-determining factors mentioned above, the costs calculated in this report should be understood to represent very rough cost estimates for the various hypothetical wastes. Actual costs could be higher or could be lower due to quantity discounts or other factors.« less
Janowski, John Patrick B; Garrett, William S; Feller, Daniel J; Hathaway, Rebecca; Kushner, John; Pelish, Matthew; Agins, Bruce D
2014-09-01
Rising rates of sexually transmitted infections (STIs) warrant a renewed focus on the management of STIs in health care organizations. The extent to which hospitals and community health centers (CHCs) have established processes and allocated staff for the management of STIs within their organizations remains poorly understood. A New York State Department of Health survey was distributed electronically through a closed state communication network to targeted administrators at New York State hospitals and CHCs. The survey asked if STI management in their facilities included the following: the ability to measure and report rates of STIs, a process to assess the quality of STI care and treatment outcomes, and a centralized person/unit to coordinate its work throughout the facility. Multivariate analysis was performed to identify whether organizational characteristics were associated with survey findings. Ninety-five percent (243/256) of hospitals and CHCs responded to the survey. Fifty percent of respondents had a person or unit to report rates of STIs; 30% reported an organization-wide process for monitoring the quality of STI care, which, according to the multivariate analysis, was associated with CHCs; only 23% reported having a centralized person or unit for coordinating STI management. Most facilities report STI cases to comply with public health surveillance requirements but do not measure infection rates, assess the quality of STI care, or coordinate its work throughout the facility. The development of this organizational capacity would likely decrease STI rates, improve treatment outcomes, and address local public health goals.
Pilot-scale laboratory waste treatment by supercritical water oxidation.
Oshima, Yoshito; Hayashi, Rumiko; Yamamoto, Kazuo
2006-01-01
Supercritical water oxidation (SCWO) is a reaction in which organics in an aqueous solution can be oxidized by O2 to CO2 and H2O at a very high reaction rate. In 2003, The University of Tokyo constructed a facility for the SCWO process, the capacity of which is approximately 20 kl/year, for the purpose of treating organic laboratory waste. Through the operation of this facility, we have demonstrated that most of the organics in laboratory waste including halogenated organic compounds can be successfully treated without the formation of dioxines, suggesting that SCWO is useful as an alternative technology to the conventional incineration process.
7 CFR 305.5 - Treatment requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Treatment requirements. 305.5 Section 305.5... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Chemical Treatments § 305.5 Treatment requirements. (a) Certified facility. The fumigation treatment facility must be certified by APHIS. Facilities...
Changes in water quality in agricultural catchments after deployment of wastewater treatment plant.
Langhammer, Jakub; Rödlová, Sylva
2013-12-01
Insufficient wastewater remediation in small communities and nonpoint source pollution are the key factors in determining the water quality of small streams in an agricultural landscape. Despite the current extensive construction of municipal wastewater treatment facilities in small communities, the level of organic substances and nutrients in the recipient catchments has not decreased in many areas. This paper analyzes the changes in the water quality of the small streams after the deployment of wastewater treatment plants that were designed to address sources of pollution from small municipalities. The analysis is based on the results from a water quality monitoring network in the small watersheds in the Czech Republic. Five rural catchments with one dominant municipal pollution source, where a wastewater treatment plant was deployed during the monitoring period, were selected according to a predefined set of criteria, from a series of 317 profiles. Basic water quality indicators were selected for the assessment: O₂, BOD-5, COD, TOC, conductivity, NH₄-N, NO₂-N, NO₃-N, PT, and PO₄-P. Results of the analysis showed that the simple deployment of the water treatment facilities at these streams often did not lead to a reduction of contamination in the streams. The expected post-deployment changes, namely, a significant and permanent reduction of stream contamination, occurred only in one catchment, whereas in the remainder of the catchments, only marginal changes or even increased concentrations of the contaminants were detected. As the critical factors that determined the efficiency of wastewater treatment were studied, the need for the consideration of the local conditions during the design of the facility, particularly regarding the size of the catchments, initial level of contamination, proper system of operation, and process optimization of the treatment facility, emerged as the important factor.
Wait, Isaac W; Johnston, Cliff T; Blatchley, Ernest R
2007-06-01
Ultraviolet (UV) disinfection systems are incorporated into drinking water production facilities because of their broad-spectrum antimicrobial capabilities, and the minimal disinfection by-product formation that generally accompanies their use. Selection of an optimal location for a UV system within a drinking water treatment facility depends on many factors; a potentially important consideration is the effect of system location on operation and maintenance issues, including the potential for fouling of quartz surfaces. To examine the effect of system location on fouling, experiments were conducted at a groundwater treatment facility, wherein aeration, chlorination, and sand filtration were applied sequentially for treatment. In this facility, access to the water stream was available prior to and following each of the treatment steps. Therefore, it was possible to examine the effects of each of these unit operations on fouling dynamics within a UV system. Results indicated zero-order formation kinetics for the fouling reactions at all locations. Increases in oxidation reduction potential, caused by water treatment steps such as aeration and chlorination, increased the rate of sleeve fouling and the rate of irradiance loss within the reactor. Analysis of metals in the sleeve foulant showed that calcium and iron predominate, and relative comparisons of foulant composition to water chemistry highlighted a high affinity for incorporation into the foulant matrix for both iron and manganese, particularly after oxidizing treatment steps. Fouling behavior was observed to be in qualitative agreement with representations of the degree of saturation, relative to the metal:ligand combinations that are believed to comprise a large fraction of the foulants that accumulate on the surfaces of quartz jackets in UV systems used to treat water.
d'Antonio, Luca; Fabbricino, Massimiliano; Pontoni, Ludovico
2015-01-01
The paper investigates, at a laboratory scale, the applicability of anaerobic digestion for the treatment of pressed-off leachate produced in a biomechanical treatment plant for municipal solid waste. Batch tests show that the anaerobic process proceeds smoothly and produces about 10,000 mL of methane per litre of treated leachate. The process is characterized by a lag phase lasting about 30 days, and is completed in about 2 months. Chemical oxygen demand (COD) and volatile fatty acids monitoring allows studying process kinetics that are modelled through a triple linear expression. Physical and biological treatments are also investigated to reduce the residual organic charge of the produced digestate. The best performances are obtained via aerobic degradation followed by assisted sedimentation. This cycle reduces the residual COD of about 85%, and allows the correct disposal of the final waste stream.
Lü, Jianhua; Zhang, Huina
2016-01-01
Heat treatment is a popular alternative to synthetic pesticides in disinfesting food-processing facilities and empty grain storages. Sitophilus zeamais Mostchulsky is one of the most cosmopolitan and destructive insects found in empty grain storage facilities and processing facilities. The effect of acclimation in S. zeamais adults to sublethal high temperature on their subsequent susceptibility to high temperatures was investigated. S. zeamais adults were acclimated to 36°C for 0 (as a control), 1, 3, and 5 h, and then were exposed at 43, 47, 51, and 55°C for different time intervals respectively. Acclimation to sublethal high temperature significantly reduced subsequent susceptibility of S. zeamais adults to lethal high temperatures of 43, 47, 51, and 55°C, although the mortality of S. zeamais adults significantly increased with increasing exposure time at lethal high temperatures. The mortality of S. zeamais adults with 1, 3, and 5 h of acclimation to 36°C was significantly lower than that of S. zeamais adults without acclimation when exposed to the same lethal high temperatures. The present results suggest that the whole facility should be heated to target lethal high temperature as soon as possible, avoiding decreasing the control effectiveness of heat treatment due to the acclimation in stored product insects to sublethal temperature. PMID:27462906
This NESHAP applies to facilities using pressure or thermal treatment processes involving wood preservatives containing chromium, arsenic, dioxins, or methylene chloride. Page includes rule summary, rule history and additional documents.
This NESHAP applies to facilities using pressure or thermal treatment processes involving wood preservatives containing chromium, arsenic, dioxins, or methylene chloride. Inlcudes federal register citations, rule history and additional resources.
77 FR 42621 - Irradiation Treatment; Location of Facilities in the Southern United States
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
.... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... amending the phytosanitary treatment regulations to provide generic criteria for new irradiation treatment facilities in the Southern States of the United States. This action will allow irradiation facilities to be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos, Gretchen M.; Terusaki, Stan H.
2013-12-01
An ecological risk assessment is required as part of the Resource Recovery and Conservation Act (RCRA) permit renewal process for Miscellaneous Units subject to 22 CCR 66270.23. This risk assessment is prepared in support of the RCRA permit renewal for the Explosives Waste Treatment Facility (EWTF) at Site 300 of the Lawrence Livermore National Laboratory (LLNL). LLNL collected soil samples and used the resulting data to produce a scoping-level ecological risk assessment pursuant to the Department of Toxic Substances Control, Guidance for Ecological Risk Assessment at Hazardous Waste Sites and Permitted Facilities, Part A: Overview, July 4, 1996. The scoping-levelmore » ecological risk assessment provides a framework to determine the potential interaction between ecological receptors and chemicals of concern from hazardous waste treatment operations in the area of EWTF. A scoping-level ecological risk assessment includes the step of conducting soil sampling in the area of the treatment units. The Sampling Plan in Support of the Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory, (Terusaki, 2007), outlines the EWTF project-specific soil sampling requirements. Soil samples were obtained and analyzed for constituents from four chemical groups: furans, explosives, semi-volatiles and metals. Analytical results showed that furans, explosives and semi-volatiles were not detected; therefore, no further analysis was conducted. The soil samples did show the presence of metals. Soil samples analyzed for metals were compared to site-wide background levels, which had been developed for site -wide cleanup activities pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Total metal concentrations from 28 discrete soil samples obtained in the EWTF area were all below CERCLA-developed background levels. Therefore, following DTSC 1996 guidance, the EWTF hazardous waste treatment units exit the ecological risk evaluation process upon completion of the requirements of a scoping-level assessment report. This summary report documents that the requirements of a scoping-level assessment have been met.« less
ERIC Educational Resources Information Center
Marsden, Mary Ellen, Ed.; Straw, Richard S., Ed.
This report presents methodology and findings from the Uniform Facility Data Set (UFDS) 1997 Survey of Correctional Facilities, which surveyed about 7,600 adult and juvenile correctional facilities to identify those that provide on-site substance abuse treatment to their inmates or residents. The survey assesses substance abuse treatment provided…
Assess and improve the sustainability of water treatment facility using Computational Fluid Dynamics
NASA Astrophysics Data System (ADS)
Zhang, Jie; Tejada-Martinez, Andres; Lei, Hongxia; Zhang, Qiong
2016-11-01
Fluids problems in water treatment industry are often simplified or omitted since the focus is usually on chemical process only. However hydraulics also plays an important role in determining effluent water quality. Recent studies have demonstrated that computational fluid dynamics (CFD) has the ability to simulate the physical and chemical processes in reactive flows in water treatment facilities, such as in chlorine and ozone disinfection tanks. This study presents the results from CFD simulations of reactive flow in an existing full-scale ozone disinfection tank and in potential designs. Through analysis of the simulation results, we found that baffling factor and CT10 are not optimal indicators of disinfection performance. We also found that the relationship between effluent CT (the product of disinfectant concentration and contact time) obtained from CT transport simulation and baffling factor depends on the location of ozone release. In addition, we analyzed the environmental and economic impacts of ozone disinfection tank designs and developed a composite indicator to quantify the sustainability of ozone disinfection tank in technological, environmental and economic dimensions.
Uyaguari, Miguel I.; Fichot, Erin B.; Scott, Geoffrey I.; Norman, R. Sean
2011-01-01
Wastewater treatment plants (WWTPs) are engineered structures that collect, concentrate, and treat human waste, ultimately releasing treated wastewater into local environments. While WWTPs efficiently remove most biosolids, it has been shown that many antibiotics and antibiotic-resistant bacteria can survive the treatment process. To determine how WWTPs influence the concentration and dissemination of antibiotic-resistant genes into the environment, a functional metagenomic approach was used to identify a novel antibiotic resistance gene within a WWTP, and quantitative PCR (qPCR) was used to determine gene copy numbers within the facility and the local coastal ecosystem. From the WWTP metagenomic library, the fosmid insert contained in one highly resistant clone (MIC, ∼416 μg ml−1 ampicillin) was sequenced and annotated, revealing 33 putative genes, including a 927-bp gene that is 42% identical to a functionally characterized β-lactamase from Staphylococcus aureus PC1. Isolation and subcloning of this gene, referred to as blaM-1, conferred ampicillin resistance to its Escherichia coli host. When normalized to volume, qPCR showed increased concentrations of blaM-1 during initial treatment stages but 2-fold-decreased concentrations during the final treatment stage. The concentration ng−1 DNA increased throughout the WWTP process from influent to effluent, suggesting that blaM-1 makes up a significant proportion of the overall genetic material being released into the coastal ecosystem. Average discharge was estimated to be 3.9 × 1014 copies of the blaM-1 gene released daily into this coastal ecosystem. Furthermore, the gene was observed in all sampled coastal water and sediment samples surrounding the facility. Our results suggest that WWTPs may be a pathway for the dissemination of novel antibiotic resistance genes into the environment. PMID:21965412
NASA Astrophysics Data System (ADS)
Bingsheng, Xu
2017-04-01
Considering the large quantities of wastewater generated from iron and steel enterprises in China, this paper is aimed to research the common methods applied for evaluating the integrated wastewater treatment effect of iron and steel enterprises. Based on survey results on environmental protection performance, technological economy, resource & energy consumption, services and management, an indicator system for evaluating the operation effect of integrated wastewater treatment facilities is set up. By discussing the standards and industrial policies in and out of China, 27 key secondary indicators are further defined on the basis of investigation on main equipment and key processes for wastewater treatment, so as to determine the method for setting key quantitative and qualitative indicators for evaluation indicator system. It is also expected to satisfy the basic requirements of reasonable resource allocation, environmental protection and sustainable economic development, further improve the integrated wastewater treatment effect of iron and steel enterprises, and reduce the emission of hazardous substances and environmental impact.
Kassie, Getnet M; Belay, Teklu; Sharma, Anjali; Feleke, Getachew
2018-01-01
Focus on improving access and quality of HIV care and treatment gained acceptance in Ethiopia through the work of the International Training and Education Center for Health. The initiative deployed mobile field-based teams and capacity building teams to mentor health care providers on clinical services and program delivery in three regions, namely Tigray, Amhara, and Afar. Transitioning of the clinical mentoring program (CMP) began in 2012 through capacity building and transfer of skills and knowledge to local health care providers and management. The initiative explored the process of transitioning a CMP on HIV care and treatment to local ownership and documented key lessons learned. A mixed qualitative design was used employing focus group discussions, individual in-depth interviews, and review of secondary data. The participants included regional focal persons, mentors, mentees, multidisciplinary team members, and International Training and Education Center for Health (I-TECH) staff. Three facilities were selected in each region. Data were collected by trained research assistants using customized guides for interviews and with data extraction format. The interviews were recorded and fully transcribed. Open Code software was used for coding and categorizing the data. A total of 16 focus group discussions and 20 individual in-depth interviews were conducted. The critical processes for transitioning a project were: establishment of a mentoring transition task force, development of a roadmap to define steps and directions for implementing the transition, and signing of a memorandum of understanding (MOU) between the respective regional health bureaus and I-TECH Ethiopia to formalize the transition. The elements of implementation included mentorship and capacity building, joint mentoring, supportive supervision, review meetings, and independent mentoring supported by facility-based mechanisms: multidisciplinary team meetings, case-based discussions, and catchment area meetings. The process of transitioning the CMP to local ownership involved signing an MOU, training of mentors, and building capacity of mentoring in each region. The experience shed light on how to transition donor-supported work to local country ownership, with key lessons related to strengthening the structures of regional health bureaus, and other facilities addressing critical issues and ensuring continuity of the facility-based activities.
40 CFR 403.19 - Provisions of specific applicability to the Owatonna Waste Water Treatment Facility.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the Owatonna Waste Water Treatment Facility. 403.19 Section 403.19 Protection of Environment... Owatonna Waste Water Treatment Facility. (a) For the purposes of this section, the term “Participating... Industrial User discharging to the Owatonna Waste Water Treatment Facility in Owatonna, Minnesota, when a...
Study on patient-induced radioactivity during proton treatment in hengjian proton medical facility.
Wu, Qingbiao; Wang, Qingbin; Liang, Tianjiao; Zhang, Gang; Ma, Yinglin; Chen, Yu; Ye, Rong; Liu, Qiongyao; Wang, Yufei; Wang, Huaibao
2016-09-01
At present, increasingly more proton medical facilities have been established globally for better curative effect and less side effect in tumor treatment. Compared with electron and photon, proton delivers more energy and dose at its end of range (Bragg peak), and has less lateral scattering for its much larger mass. However, proton is much easier to produce neutron and induced radioactivity, which makes radiation protection for proton accelerators more difficult than for electron accelerators. This study focuses on the problem of patient-induced radioactivity during proton treatment, which has been ignored for years. However, we confirmed it is a vital factor for radiation protection to both patient escort and positioning technician, by FLUKA's simulation and activation formula calculation of Hengjian Proton Medical Facility (HJPMF), whose energy ranges from 130 to 230MeV. Furthermore, new formulas for calculating the activity buildup process of periodic irradiation were derived and used to study the relationship between saturation degree and half-life of nuclides. Finally, suggestions are put forward to lessen the radiation hazard from patient-induced radioactivity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Application countermeasures of non-incineration technologies for medical waste treatment in China.
Chen, Yang; Ding, Qiong; Yang, Xiaoling; Peng, Zhengyou; Xu, Diandou; Feng, Qinzhong
2013-12-01
By the end of 2012, there were 272 modern, high-standard, centralized medical waste disposal facilities operating in various cities in China. Among these facilities nearly 50% are non-incineration treatment facilities, including the technologies of high temperature steam, chemical disinfection and microwave. Each of the non-incineration technologies has its advantages and disadvantages, and any single technology cannot offer a panacea because of the complexity of medical waste disposal. Although non-incineration treatment of medical waste can avoid the release of polychlorinated dibenzo-p-dioxins/dibenzofurans, it is still necessary to decide how to best meet the local waste management needs while minimizing the impact on the environment and public health. There is still a long way to go to establish the sustainable application and management mode of non-incineration technologies. Based on the analysis of typical non-incineration process, pollutant release, and the current tendency for technology application and development at home and abroad, this article recommends the application countermeasures of non-incineration technologies as the best available techniques and best environmental practices in China.
Environmental factor(tm) system: RCRA hazardous waste handler information (on CD-ROM). Data file
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-01
Environmental Factor(trademark) RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity, and compliance history for facilities found in the EPA Research Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management, and minimization by companies who are large quantity generators; and (3) Data on the waste management practices of treatment, storage, and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action, or violation information, TSD status, generator and transporter status, and more. (2) View compliance information - dates of evaluation, violation, enforcement, and corrective action. (3) Lookup facilities by waste processing categories of marketing, transporting, processing, and energy recovery. (4) Use owner/operator information and names, titles, and telephone numbers of project managers for prospecting. (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving, and exporting.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clifford, M.J.; Wickstrom, G.V.
1983-10-01
Preferred treatment of high occupancy vehicles (HOV's), through strategies such as dedicated lanes, can achieve transportation energy conservation. The research presented in this report provides a method for regional planning agencies to assess such HOV facilities, from a travel demand and energy consumption standpoint. The planning process is described and applied in a case study. Products of the case study included estimates of carpool formation and associated fuel savings, and traffic operations on HOV and other facilities in the corridor. The completed process represents a method to examine HOV's under a variety of policy and operational conditions. The process ismore » within the modeling capabilities of other Metropolitan Planning Organizations (MPO's) and should be transferable to other cities and corridors. Additional applications of the HOV estimation and evaluation process are recommended.« less
Experiencing cancer treatment decision-making in managed care.
Wenzel, Jennifer; Shaha, Maya
2008-09-01
This paper is a report of a study to explore women's perceptions of and experiences with breast cancer treatment decision-making in managed care organizations (MCOs). Managed care organizations are the predominant form of employer-sponsored healthcare insurance in the United States of America. These healthcare financing entities minimize cost by streamlining healthcare delivery and may impose choice restrictions. The extent of these restrictions has not previously been studied from an in-depth patient perspective. A qualitative descriptive approach was adopted using interviews with a purposive sample of 14 managed care enrollees diagnosed with breast cancer at all stages. The data were collected between 2003 and 2005. Data analysis involved a reflexive process of transcript reading, categorization, data reduction and interpretation. The findings are presented as a single theme: 'decisional conflict in managed care', with two distinct categories: decisions regarding (1) the MCOs and (2) treatment. MCO selection was perceived to be limited by employer constraints, cost issues or healthcare plan providers. For study participants, selecting a MCO was less difficult than issues surrounding treatment decision-making. Women reported that their most important treatment-related decisions surrounded diagnosis and involved selecting a treatment facility and provider. Once a satisfactory facility and provider were selected, these women preferred to defer treatment decisions to their healthcare providers. Decision interventions should be focused on assisting women with provider and treatment facility selection early in diagnosis. Our findings might also serve as a basis for policy/practice changes to address healthcare financing limitations and to expand cancer treatment-related choices while providing desired treatment decision-making support.
Liquid secondary waste. Waste form formulation and qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cozzi, A. D.; Dixon, K. L.; Hill, K. A.
The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams generated during Site cleanup activities. When the Hanford Tank Waste Treatment and Immobilization Plant (WTP) begins operations, a liquid secondary waste (LSW) stream from the WTP will need to be treated. The volume of effluent for treatment at the ETF will increase significantly. Washington River Protection Solutions is implementing a Secondary Liquid Waste Immobilization Technology Development Plan to address the technology needs for a waste form and solidification process to treat the increased volume of waste planned for disposal at the Integrated Disposal Facility IDF). Waste form testingmore » to support this plan is composed of work in the near term to demonstrate the waste form will provide data as input to a performance assessment (PA) for Hanford’s IDF.« less
Waste Estimates for a Future Recycling Plant in the US Based Upon AREVA Operating Experience - 13206
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foare, Genevieve; Meze, Florian; Bader, Sven
2013-07-01
Estimates of process and secondary wastes produced by a recycling plant built in the U.S., which is composed of a used nuclear fuel (UNF) reprocessing facility and a mixed oxide (MOX) fuel fabrication facility, are performed as part of a U.S. Department of Energy (DOE) sponsored study [1]. In this study, a set of common inputs, assumptions, and constraints were identified to allow for comparison of these wastes between different industrial teams. AREVA produced a model of a reprocessing facility, an associated fuel fabrication facility, and waste treatment facilities to develop the results for this study. These facilities were dividedmore » into a number of discrete functional areas for which inlet and outlet flow streams were clearly identified to allow for an accurate determination of the radionuclide balance throughout the facility and the waste streams. AREVA relied primarily on its decades of experience and feedback from its La Hague (reprocessing) and MELOX (MOX fuel fabrication) commercial operating facilities in France to support this assessment. However, to perform these estimates for a U.S. facility with different regulatory requirements and to take advantage of some technological advancements, such as in the potential treatment of off-gases, some deviations from this experience were necessary. A summary of AREVA's approach and results for the recycling of 800 metric tonnes of initial heavy metal (MTIHM) of LWR UNF per year into MOX fuel under the assumptions and constraints identified for this DOE study are presented. (authors)« less
LOW ACTIVITY WASTE FEED SOLIDS CARACTERIZATION AND FILTERABILITY TESTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCabe, D.; Crawford, C.; Duignan, M.
The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for the WTP Pretreatment facility is to treat the waste, splitting it into High Level Waste (HLW) feed and Low Activity Waste (LAW) feed. Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium in the WTP Pretreatment facility, so itsmore » disposition path is the LAW glass. Options are being explored to immobilize the LAW portion of the tank waste, i.e., the LAW feed from the WTP Pretreatment facility. Removal of {sup 99}Tc from the LAW Feed, followed by off-site disposal of the {sup 99}Tc, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for LAW treatment and disposal that could benefit from technetium removal. One of these flowsheets will specifically examine removing {sup 99}Tc from the LAW feed stream to supplemental immobilization. The conceptual flow sheet of the {sup 99}Tc removal process includes a filter to remove insoluble solids prior to processing the stream in an ion exchange column, but the characteristics and behavior of the liquid and solid phases has not previously been investigated. This report contains results of testing of a simulant that represents the projected composition of the feed to the Supplemental LAW process. This feed composition is not identical to the aqueous tank waste fed to the Waste Treatment Plant because it has been processed through WTP Pretreatment facility and therefore contains internal changes and recycle streams that will be generated within the WTP process. Although a Supplemental LAW feed simulant has previously been prepared, this feed composition differs from that simulant because those tests examined only the fully soluble aqueous solution at room temperature, not the composition formed after evaporation, including the insoluble solids that precipitate after it cools. The conceptual flow sheet for Supplemental LAW immobilization has an option for removal of {sup 99}Tc from the feed stream, if needed. Elutable ion exchange has been selected for that process. If implemented, the stream would need filtration to remove the insoluble solids prior to processing in an ion exchange column. The characteristics, chemical speciation, physical properties, and filterability of the solids are important to judge the feasibility of the concept, and to estimate the size and cost of a facility. The insoluble solids formed during these tests were primarily natrophosphate, natroxalate, and a sodium aluminosilicate compound. At the elevated temperature and 8 M [Na+], appreciable insoluble solids (1.39 wt%) were present. Cooling to room temperature and dilution of the slurry from 8 M to 5 M [Na+] resulted in a slurry containing 0.8 wt% insoluble solids. The solids (natrophosphate, natroxalate, sodium aluminum silicate, and a hydrated sodium phosphate) were relatively stable and settled quickly. Filtration rates were in the range of those observed with iron-based simulated Hanford tank sludge simulants, e.g., 6 M [Na+] Hanford tank 241-AN-102, even though their chemical speciation is considerably different. Chemical cleaning of the crossflow filter was readily accomplished with acid. As this simulant formulation was based on an average composition of a wide range of feeds using an integrated computer model, this exact composition may never be observed. But the test conditions were selected to enable comparison to the model to enable improving its chemical prediction capability.« less
Tianyi, Frank-Leonel; Tochie, Joel Noutakdie; Agbor, Valirie Ndip; Kadia, Benjamin Momo
2018-03-01
HIV testing is an invaluable entry point to prevention, care and treatment services for people living with HIV and AIDS. Poor adherence to recommended protocols and guidelines reduces the performance of rapid diagnostic tests, leading to misdiagnosis and poor estimation of HIV seroprevalence. This study seeks to evaluate the adherence of primary healthcare facilities in Cameroon to recommended HIV counselling and testing (HCT) procedures and the impact this may have on the reliability of HIV test results. This will be an analytical cross-sectional study involving primary healthcare facilities from all the 10 regions of Cameroon, selected by a multistaged random sampling of primary care facilities in each region. The study will last for 9 months. A structured questionnaire will be used to collect general information concerning the health facility, laboratory and other departments involved in the HCT process. The investigators will directly observe at least 10 HIV testing processes in each facility and fill out the checklist accordingly. Clearance has been obtained from the National Ethical Committee to carry out the study. Informed consent will be sought from the patients to observe the HIV testing process. The final study will be published in a peer-reviewed journal and the findings presented to health policy-makers and the general public. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
ERIC Educational Resources Information Center
Blodgett, Cynthia S.
2008-01-01
The purpose of this grounded theory study was to examine the process by which people with Mild Traumatic Brain Injury (MTBI) access information on the web. Recent estimates include amateur sports and recreation injuries, non-hospital clinics and treatment facilities, private and public emergency department visits and admissions, providing…
42 CFR 483.354 - General requirements for psychiatric residential treatment facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... treatment facilities. 483.354 Section 483.354 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... LONG TERM CARE FACILITIES Condition of Participation for the Use of Restraint or Seclusion in Psychiatric Residential Treatment Facilities Providing Inpatient Psychiatric Services for Individuals Under...
Pérez, J F; Llanos, J; Sáez, C; López, C; Cañizares, P; Rodrigo, M A
2017-06-15
Wastewater produced in pharmaceutical manufacturing plants (PMPs), especially the one coming from organic-synthesis facilities, is characterized by its large variability due to the wide range of solvents and chemical reagents used in the different stages of the production of medicines. Normally, the toxicity of the organic compounds prevent the utilization of biological processes and more powerful treatments are needed becoming advanced oxidation processes (AOPs) a valid alternative. In this work, the efficiency in abatement of pollution by Fenton oxidation (FO) and conductive-diamond electro-oxidation (CDEO) are compared in the treatment of 60 real effluents coming from different processes carried out in a pharmaceutical facility, using standardized tests. In 80% of the samples, CDEO was found to be more efficient than FO and in the remaining 20%, coagulation was found to exhibit a great significance in the COD abatement mechanism during FO, pointing out the effectiveness of the oxidation promoted by the electrochemical technology. Mean oxidation state of carbon was found to be a relevant parameter to understand the behavior of the oxidation technologies. It varied inversely proportional to efficiency in FO and it showed practically no influence in the case of CDEO. Copyright © 2016 Elsevier Ltd. All rights reserved.
Moon, Jinyoung; Hwang, Yongwoo; Kim, Junbeum; Kwak, Inho
Recent toughened water quality standards have necessitated improvements for existing sewer treatment facilities through advanced treatment processes. Therefore, an advanced treatment process that can be installed through simple modification of existing sewer treatment facilities needs to be developed. In this study, a new submerged membrane bioreactor process packed with granular sulfur (MBR-GS) was developed and operated to determine the biological nitrogen removal behaviors of plating wastewater containing a high concentration of NO3(-). Continuous denitrification was carried out at various nitrogen loading rates at 20 °C using synthetic wastewater, which was comprised of NO3(-) and HCO3(-), and actual plating wastewater, which was collected from the effluent water of a plating company called 'H Metals'. High-rate denitrification in synthetic plating wastewater was accomplished at 0.8 kg NO3(-)-N/m(3)·day at a nitrogen loading rate of 0.9 kg NO3(-)-N/m(3)·day. The denitrification rate further increased in actual plating wastewater to 0.91 kg NO3(-)-N/m(3)·day at a nitrogen loading rate of 1.11 kg NO3(-)-N/m(3)·day. Continuous filtration was maintained for up to 30 days without chemical cleaning with a transmembrane pressure in the range of 20 cmHg. Based on stoichiometry, SO4(2-) production and alkalinity consumption could be calculated theoretically. Experimental alkalinity consumption was lower than the theoretical value. This newly proposed MBR-GS process, capable of high-rate nitrogen removal by compulsive flux, is expected to be applicable as an alternative renovation technique for nitrogen treatment of plating wastewater as well as municipal wastewater with a low C/N ratio.
Hanford facility dangerous waste permit application, general information portion. Revision 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonnichsen, J.C.
1997-08-21
For purposes of the Hanford facility dangerous waste permit application, the US Department of Energy`s contractors are identified as ``co-operators`` and sign in that capacity (refer to Condition I.A.2. of the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit). Any identification of these contractors as an ``operator`` elsewhere in the application is not meant to conflict with the contractors` designation as co-operators but rather is based on the contractors` contractual status with the U.S. Department of Energy, Richland Operations Office. The Dangerous Waste Portion of the initial Hanford Facility Resource Conservation and Recovery Act Permit,more » which incorporated five treatment, storage, and/or disposal units, was based on information submitted in the Hanford Facility Dangerous Waste Permit Application and in closure plan and closure/postclosure plan documentation. During 1995, the Dangerous Waste Portion was modified twice to incorporate another eight treatment, storage, and/or disposal units; during 1996, the Dangerous Waste Portion was modified once to incorporate another five treatment, storage, and/or disposal units. The permit modification process will be used at least annually to incorporate additional treatment, storage, and/or disposal units as permitting documentation for these units is finalized. The units to be included in annual modifications are specified in a schedule contained in the Dangerous Waste Portion of the Hanford Facility Resource Conservation and Recovery Act Permit. Treatment, storage, and/or disposal units will remain in interim status until incorporated into the Permit. The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion is limited to individual operating treatment, storage, and/or disposal units for which Part B permit application documentation has been, or is anticipated to be, submitted. Documentation for treatment, storage, and/or disposal units undergoing closure, or for units that are, or are anticipated to be, dispositioned through other options, will continue to be submitted by the Permittees in accordance with the provisions of the Hanford Federal Facility Agreement and Consent Order. However, the scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Both the General Information and Unit-Specific portions of the Hanford Facility Dangerous Waste Permit Application address the contents of the Part B permit application guidance documentation prepared by the Washington State Department of Ecology and the U.S. Environmental Protection Agency, with additional information needs defined by revisions of Washington Administrative Code 173-303 and by the Hazardous and Solid Waste Amendments. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (i.e., either operating units, units undergoing closure, or units being dispositioned through other options).« less
Gaythorpe, Katy; Adams, Ben
2016-05-21
Epidemics of water-borne infections often follow natural disasters and extreme weather events that disrupt water management processes. The impact of such epidemics may be reduced by deployment of transmission control facilities such as clinics or decontamination plants. Here we use a relatively simple mathematical model to examine how demographic and environmental heterogeneities, population behaviour, and behavioural change in response to the provision of facilities, combine to determine the optimal configurations of limited numbers of facilities to reduce epidemic size, and endemic prevalence. We show that, if the presence of control facilities does not affect behaviour, a good general rule for responsive deployment to minimise epidemic size is to place them in exactly the locations where they will directly benefit the most people. However, if infected people change their behaviour to seek out treatment then the deployment of facilities offering treatment can lead to complex effects that are difficult to foresee. So careful mathematical analysis is the only way to get a handle on the optimal deployment. Behavioural changes in response to control facilities can also lead to critical facility numbers at which there is a radical change in the optimal configuration. So sequential improvement of a control strategy by adding facilities to an existing optimal configuration does not always produce another optimal configuration. We also show that the pre-emptive deployment of control facilities has conflicting effects. The configurations that minimise endemic prevalence are very different to those that minimise epidemic size. So cost-benefit analysis of strategies to manage endemic prevalence must factor in the frequency of extreme weather events and natural disasters. Copyright © 2016 Elsevier Ltd. All rights reserved.
PROCESS DESIGN MANUAL FOR SLUDGE TREATMENT AND DISPOSAL
The purpose of this manual is to provide the engineering community and related industry with a new source of information to be used in the planning, design, and operation of present and future wastewater pollution control facilities. This manual supplements this existing knowledg...
Could peracetic acid be an alternative treatment in aquaculture?
USDA-ARS?s Scientific Manuscript database
Peracetic acid (PAA) is an antimicrobial disinfectant used in agriculture, food processing and medical facilities. It has recently been tested as a means to control infestations of Ichthyophthirius multifiliis and Saprolegnia parasitica. Free-swimming theronts of I. multifiliis can be eliminated u...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-16
... TRICARE: Unfortunate Sequelae From Noncovered Services in a Military Treatment Facility AGENCY: Office of... treatment of complications (unfortunate sequelae) resulting from a noncovered incident of treatment provided in a Military Treatment Facility (MTF), when the initial noncovered service has been authorized by...
Spent fuel treatment at ANL-West
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goff, K.M.; Benedict, R.W.; Levinskas, D.
1994-12-31
At Argonne National Laboratory-West (ANL-West) there are several thousand kilograms of metallic spent nuclear fuel containing bond sodium. This fuel will be treated in the Fuel Cycle Facility at ANL-West to produce stable waste forms for storage and disposal. The treatment operations will employ a pyrochemical process that also has applications for treating most of the fuel types within the Department of Energy complex. The treatment equipment is in its last stage of readiness, and operations will begin in the Fall of 1994.
Wang, Langping; Huang, Lei; Xie, Zhiwen; Wang, Xiaofeng; Tang, Baoyin
2008-02-01
The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.
Secondary Waste Form Development and Optimization—Cast Stone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sundaram, S. K.; Parker, Kent E.; Valenta, Michelle M.
2011-07-14
Washington River Protection Services is considering the design and construction of a Solidification Treatment Unit (STU) for the Effluent Treatment Facility (ETF) at Hanford. The ETF is a Resource Conservation and Recovery Act-permitted, multi-waste, treatment and storage unit and can accept dangerous, low-level, and mixed wastewaters for treatment. The STU needs to be operational by 2018 to receive secondary liquid wastes generated during operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The STU to ETF will provide the additional capacity needed for ETF to process the increased volume of secondary wastes expected to be produced by WTP.
Mariko, Mamadou
2003-03-01
The public finance and foreign exchange crisis of the 1980s aggravated the unfavourable economic trends in many developing countries and resulted in budget cuts in the health sector. Policymakers, following the suggestions of World Bank experts, introduced user fees. Economic analysis of the demand for health care in these countries focused on the impact of price and income on health service utilisation. But the lesson to date from experiences in cost recovery is that without visible and fairly immediate improvements in the quality of care, the implementation of user fees will cause service utilisation to drop. For this reason, the role of quality of health care has been recently a subject of investigation in a number of health care demand studies. In spite of using the data from both households and facilities, recent studies are quite limited because they measure quality only by structural attributes (availability of drugs, equipment, number and qualifications of staff, and so on). Structural attributes of quality are necessary but not sufficient conditions for demand. A unique feature of this study is that it also considers the processes followed by practitioners and the outcome of care, to determine simultaneously the respective influence of price and quality on decision making. A nested multinomial logit was used to examine the choice between six alternatives (self-treatment, modern treatment at home, public hospital, public dispensary, for-profit facility and non-profit facility). The estimations are based on data from a statistically representative sample of 1104 patients from 1191 households and the data from a stratified random sample of 42 out of 84 facilities identified. The results indicate that omitting the process quality variables from the demand model produces a bias not only in the estimated coefficient of the "price" variable but also in coefficients of some structural attributes of the quality. The simulations suggest that price has a minor effect on utilisation of health services, and that health authorities can simultaneously double user fees and increase utilisation by emphasising improvement of both the structural and process quality of care in public health facilities.
Waste Determination Equivalency - 12172
DOE Office of Scientific and Technical Information (OSTI.GOV)
Freeman, Rebecca D.
2012-07-01
The Savannah River Site (SRS) is a Department of Energy (DOE) facility encompassing approximately 800 square kilometers near Aiken, South Carolina which began operations in the 1950's with the mission to produce nuclear materials. The SRS contains fifty-one tanks (2 stabilized, 49 yet to be closed) distributed between two liquid radioactive waste storage facilities at SRS containing carbon steel underground tanks with storage capacities ranging from 2,800,000 to 4,900,000 liters. Treatment of the liquid waste from these tanks is essential both to closing older tanks and to maintaining space needed to treat the waste that is eventually vitrified or disposedmore » of onsite. Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005 (NDAA) provides the Secretary of Energy, in consultation with the Nuclear Regulatory Commission (NRC), a methodology to determine that certain waste resulting from prior reprocessing of spent nuclear fuel are not high-level radioactive waste if it can be demonstrated that the waste meets the criteria set forth in Section 3116(a) of the NDAA. The Secretary of Energy, in consultation with the NRC, signed a determination in January 2006, pursuant to Section 3116(a) of the NDAA, for salt waste disposal at the SRS Saltstone Disposal Facility. This determination is based, in part, on the Basis for Section 3116 Determination for Salt Waste Disposal at the Savannah River Site and supporting references, a document that describes the planned methods of liquid waste treatment and the resulting waste streams. The document provides descriptions of the proposed methods for processing salt waste, dividing them into 'Interim Salt Processing' and later processing through the Salt Waste Processing Facility (SWPF). Interim Salt Processing is separated into Deliquification, Dissolution, and Adjustment (DDA) and Actinide Removal Process/Caustic Side Solvent Extraction Unit (ARP/MCU). The Waste Determination was signed by the Secretary of Energy in January of 2006 based on proposed processing techniques with the expectation that it could be revised as new processing capabilities became viable. Once signed, however, it became evident that any changes would require lengthy review and another determination signed by the Secretary of Energy. With the maturation of additional salt removal technologies and the extension of the SWPF start-up date, it becomes necessary to define 'equivalency' to the processes laid out in the original determination. For the purposes of SRS, any waste not processed through Interim Salt Processing must be processed through SWPF or an equivalent process, and therefore a clear statement of the requirements for a process to be equivalent to SWPF becomes necessary. (authors)« less
CHANGES IN BACTERIAL COMPOSITION OF BIOFILM IN A METROPOLITAN DRINKING WATER DISTRIBUTION SYSTEM
This study examined the development of bacterial biofilms within a metropolitan distribution system. The distribution system is fed with different source water (i.e., groundwater, GW and surface water, SW) and undergoes different treatment processes in separate facilities. The b...
Asakura, Hiroshi; Matsuto, Toshihiko; Tanaka, Nobutoshi
2007-01-01
Influent and processed water were sampled at different points in the leachate treatment facilities of five municipal solid waste (MSW) landfill sites. Then, the concentrations of endocrine-disrupting chemicals (EDCs), namely, alkylphenols (APs), bisphenol A (BPA), phthalic acid esters (PAEs) and organotin compounds (OTs), in the treated leachate samples were determined and the behavior of the EDCs in the treatment processes was discussed. The concentrations of APs were as low as those in surface waters, and no OTs were detected (detection limit: 0.01 microg/L). Meanwhile, diethylhexyl phthalate (DEHP), which was the most abundant of the four substances measured as PAEs, and BPA were found in all of the influent samples. BPA was considerably degraded by aeration, except when the water temperature was low and the total organic carbon (TOC) was high. By contrast, aeration, biological treatment, and coagulation/sedimentation removed only a small amount of DEHP.
Shelton, Deborah; Wakai, Sara
2011-01-01
To conduct a formative evaluation of a treatment program designed for inmates with impulsive and aggressive behavior disorders in high-security facilities in Connecticut correctional facilities. Pencil-and-paper surveys and in-person inmate interviews were used to answer four evaluation questions. Descriptive statistics and content analyses were used to assess context, input, process, and products. A convenience sample of 26 adult male (18) and female (8) inmates participated in the study. Inmates were satisfied with the program (4-point scale, M = 3.38, SD = 0.75). Inmate hospital stays were reduced by 13.6%, and psychotropic medication use increased slightly (0.40%). Improved outcomes were noted for those inmates who attended more sessions. The findings of the formative evaluation were useful for moving the START NOW Skills Training treatment to the implementation phase. Recommendations for implementation modifications included development of an implementation team, reinforcement of training, and attention applied to uniform collection of outcome data to demonstrate its evidence base.
DISPOSITION PATHS FOR ROCKY FLATS GLOVEBOXES: EVALUATING OPTIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobdell, D.; Geimer, R.; Larsen, P.
2003-02-27
The Kaiser-Hill Company, LLC has the responsibility for closure activities at the Rocky Flats Environmental Technology Site (RFETS). One of the challenges faced for closure is the disposition of radiologically contaminated gloveboxes. Evaluation of the disposition options for gloveboxes included a detailed analysis of available treatment capabilities, disposal facilities, and lifecycle costs. The Kaiser-Hill Company, LLC followed several processes in determining how the gloveboxes would be managed for disposition. Currently, multiple disposition paths have been chosen to accommodate the needs of the varying styles and conditions of the gloveboxes, meet the needs of the decommissioning team, and to best managemore » lifecycle costs. Several challenges associated with developing a disposition path that addresses both the radiological and RCRA concerns as well as offering the most cost-effective solution were encountered. These challenges included meeting the radiological waste acceptance criteria of available disposal facilities, making a RCRA determination, evaluating treatment options and costs, addressing void requirements associated with disposal, and identifying packaging and transportation options. The varying disposal facility requirements affected disposition choices. Facility conditions that impacted decisions included radiological and chemical waste acceptance criteria, physical requirements, and measurement for payment options. The facility requirements also impacted onsite activities including management strategies, decontamination activities, and life-cycle cost.« less
NASA Astrophysics Data System (ADS)
Kasharin, D. V.
2017-11-01
The article tackles the issues of designing seasonal water and power supply systems for small recreational facilities in the south of Russia based on intelligent decision support systems. The paper proposes modular prefabricated shell water and power supply works (MPSW&PW) along with energy-efficient standalone water-treatment plants as the principal facilities compliant with the environmental and infrastructural requirements applied to specially protected areas and ensuring the least possible damage to the environment due to a maximum possible use of local construction materials characterized by impressive safety margins in highly seismic environments. The task of designing water and power supply systems requires the consideration of issues pertaining to the development of an intelligent GIS-based system for the selection of water intake sites that facilitate automation of data-processing systems using a priori scanning methods with a variable step and random directions. The paper duly addresses such issues and develops parameterized optimization algorithms for MPSW&PW shell facilities. It equally provides the substantiation of water-treatment plants intelligent design based on energy recovery reverse osmosis and nanofiltration plants that enhance the energy efficiency of such plants serving as the optimum solution for the decentralized water supply of small recreational facilities from renewable energy sources.
Options Assessment Report: Treatment of Nitrate Salt Waste at Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Bruce Alan; Stevens, Patrice Ann
2015-12-17
This report documents the methodology used to select a method of treatment for the remediated nitrate salt (RNS) and unremediated nitrate salt (UNS) waste containers at Los Alamos National Laboratory (LANL). The method selected should treat the containerized waste in a manner that renders the waste safe and suitable for transport and final disposal in the Waste Isolation Pilot Plant (WIPP) repository, under specifications listed in the WIPP Waste Acceptance Criteria (DOE/CBFO, 2013). LANL recognizes that the results must be thoroughly vetted with the New Mexico Environment Department (NMED) and that a modification to the LANL Hazardous Waste Facility Permitmore » is a necessary step before implementation of this or any treatment option. Likewise, facility readiness and safety basis approvals must be received from the Department of Energy (DOE). This report presents LANL’s preferred option, and the documentation of the process for reaching the recommended treatment option for RNS and UNS waste, and is presented for consideration by NMED and DOE.« less
Han, B; Kim, J; Kim, Y; Choi, J S; Makarov, I E; Ponomarev, A V
2005-01-01
A pilot plant for treating 1000 m3/day of dyeing wastewater with e-beam has been constructed and operated since 1998 in Daegu, Korea together with the biological treatment facility. The wastewater from various stages of the existing purification process has been treated with an electron beam in this plant, and it gave rise to elaborating the optimal technology of the electron beam treatment of wastewater with increased reliability for instant changes in the composition of wastewater. Installation of the e-beam pilot plant resulted in decolorizing and destructive oxidation of organic impurities in wastewater, appreciable reduction of chemical reagent consumption, in reduction of the treatment time, and in increase in the flow rate limit of existing facilities by 30-40%. Industrial plant for treating 10,000 m3/day each, based upon the pilot experimental result, is under construction and will be finished by 2005. This project is supported by the International Atomic Energy Agency (IAEA) and Korean Government.
76 FR 60390 - Irradiation Treatment; Location of Facilities in the Southern United States
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... [Docket No. APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern... irradiation treatment facilities in the Southern States of the United States. This action would allow irradiation facilities to be located anywhere in these States, subject to approval, rather than only in the...
Conversion of municipal solid waste to hydrogen
NASA Astrophysics Data System (ADS)
Richardson, J. H.; Rogers, R. S.; Thorsness, C. B.
1995-04-01
LLNL and Texaco are cooperatively developing a physical and chemical treatment method for the conversion of municipal solid waste (MSW) to hydrogen via the steps of hydrothermal pretreatment, gasification and purification. LLNL's focus has been on hydrothermal pretreatment of MSW in order to prepare a slurry of suitable viscosity and heating value to allow efficient and economical gasification and hydrogen production. The project has evolved along 3 parallel paths: laboratory scale experiments, pilot scale processing, and process modeling. Initial laboratory-scale MSW treatment results (e.g., viscosity, slurry solids content) over a range of temperatures and times with newspaper and plastics will be presented. Viscosity measurements have been correlated with results obtained at MRL. A hydrothermal treatment pilot facility has been rented from Texaco and is being reconfigured at LLNL; the status of that facility and plans for initial runs will be described. Several different operational scenarios have been modeled. Steady state processes have been modeled with ASPEN PLUS; consideration of steam injection in a batch mode was handled using continuous process modules. A transient model derived from a general purpose packed bed model is being developed which can examine the aspects of steam heating inside the hydrothermal reactor vessel. These models have been applied to pilot and commercial scale scenarios as a function of MSW input parameters and have been used to outline initial overall economic trends. Part of the modeling, an overview of the MSW gasification process and the modeling of the MSW as a process material, was completed by a DOE SERS (Science and Engineering Research Semester) student. The ultimate programmatic goal is the technical demonstration of the gasification of MSW to hydrogen at the laboratory and pilot scale and the economic analysis of the commercial feasibility of such a process.
Adejumo, Olusola Adedeji; Daniel, Olusoji James; Otesanya, Andrew Folarin; Salisu-Olatunj, Shukrat Olajumoke; Abdur-Razzaq, Husseine A
2017-01-01
The engagement of private practitioners in the public-private mix of tuberculosis (TB) management started in 2007 in Lagos State Nigeria. This study compared the treatment outcomes of patients managed at private for profit (PFP) and private not for profit (PNFP) directly observed treatment short course (DOTS) facilities. A retrospective review of treatment cards of TB patients managed between January 1, 2012, and June 30, 2012, in seven PFP and four PNFP DOTS facilities that served as treatment and microscopy center under the Lagos State TB and Leprosy Control Programme (LSTBLCP) at least 2 years before data collection was conducted. A total of 372 treatment cards of TB patients were reviewed, of which 132 (35.5%) and 240 (64.5%) were from PFP and PNFP DOTS facilities, respectively. Treatment success rate was higher among patients managed at PFP (89.4%) DOTS facilities than PNFP (81.3%) DOTS facilities ( P = 0.04). The proportion of patients lost to follow-up (12.5% vs. 8.3%), dead (3.3% vs. 1.5%) and treatment failure (2.5% vs. 0.8%) was higher among patients managed at PNFP DOTS facilities ( P > 0.05). The odds that patients treated at PFP DOTS facilities had treatment success were about four times higher than PNFP DOTS facilities when other variables have been controlled for ( P < 0.05). There is need by the LSTBLCP to engage more private practitioners to increase case detection and improve treatment outcomes of TB patients.
Environmental Factor(tm) system: RCRA hazardous waste handler information (on cd-rom). Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-04-01
Environmental Factor(tm) RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity and compliance history for facilities found in the EPA Resource Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management and minimization by companies who are large quantity generators, and (3) Data on the waste management practices of treatment, storage and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action or violation information, TSD status, generator and transporter status and more; (2) View compliance information - dates of evaluation, violation, enforcement and corrective action; (3) Lookup facilities by waste processing categories of marketing, transporting, processing and energy recovery; (4) Use owner/operator information and names, titles and telephone numbers of project managers for prospecting; and (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving and exporting. Hotline support is also available for no additional charge.« less
Environmental Factor{trademark} system: RCRA hazardous waste handler information
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
Environmental Factor{trademark} RCRA Hazardous Waste Handler Information on CD-ROM unleashes the invaluable information found in two key EPA data sources on hazardous waste handlers and offers cradle-to-grave waste tracking. It`s easy to search and display: (1) Permit status, design capacity and compliance history for facilities found in the EPA Resource Conservation and Recovery Information System (RCRIS) program tracking database; (2) Detailed information on hazardous wastes generation, management and minimization by companies who are large quantity generators, and (3) Data on the waste management practices of treatment, storage and disposal (TSD) facilities from the EPA Biennial Reporting System which is collectedmore » every other year. Environmental Factor`s powerful database retrieval system lets you: (1) Search for RCRA facilities by permit type, SIC code, waste codes, corrective action or violation information, TSD status, generator and transporter status and more; (2) View compliance information -- dates of evaluation, violation, enforcement and corrective action; (3) Lookup facilities by waste processing categories of marketing, transporting, processing and energy recovery; (4) Use owner/operator information and names, titles and telephone numbers of project managers for prospecting; and (5) Browse detailed data on TSD facility and large quantity generators` activities such as onsite waste treatment, disposal, or recycling, offsite waste received, and waste generation and management. The product contains databases, search and retrieval software on two CD-ROMs, an installation diskette and User`s Guide. Environmental Factor has online context-sensitive help from any screen and a printed User`s Guide describing installation and step-by-step procedures for searching, retrieving and exporting. Hotline support is also available for no additional charge.« less
NASA Astrophysics Data System (ADS)
Nikolaeva, L. A.; Khusaenova, A. Z.
2014-05-01
A method for utilizing production wastes is considered, and a process circuit arrangement is proposed for utilizing a mixture of activated silt and sludge from chemical water treatment by incinerating it with possible heat recovery. The sorption capacity of the products from combusting a mixture of activated silt and sludge with respect to gaseous emissions is experimentally determined. A periodic-duty adsorber charged with a fixed bed of sludge is calculated, and the heat-recovery boiler efficiency is estimated together with the technical-economic indicators of the proposed utilization process circuit arrangement.
An Effective Web Presence for Substance Abuse Treatment Facilities.
Link, Thomas W; Hefner, Jennifer L; Ford, Eric W; Huerta, Timothy R
2016-01-01
Website development for health care has only been prevalent in the last two and a half decades. The first websites were electronic versions of brochures providing hardly any interaction with the consumer or potential consumer. The percentage of consumers that use the internet during the decision-making process for health care providers continues to rise. As a result, the websites of health care providers are becoming more of a representation of the facility and creating an organizational image rather than a brochure-like informational page. The purpose of this study was to analyze substance abuse treatment center's websites in the State of California with the goal of informing the management of substance abuse centers regarding an effective and inexpensive means to closing the marketing gaps in the industry. This brief research report presents the results of employing an automated web-crawler to assess website quality along five dimensions: accessibility, content, marketing, technology, and usability score. The sample mean scores for all dimensions were between 4 and 6 on a 10-point scale. On average larger facilities had higher quality websites. The low mean scores on these dimensions indicate that that substance abuse centers have significant room for improvement of their website's. Efficiently spending marketing funds to increase the effectiveness of a treatment center's website can be a low cost way for even small facilities to increase market competitiveness.
Reengineering of waste management at the Oak Ridge National Laboratory. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myrick, T.E.
1997-08-01
A reengineering evaluation of the waste management program at the Oak Ridge National Laboratory (ORNL) was conducted during the months of February through July 1997. The goal of the reengineering was to identify ways in which the waste management process could be streamlined and improved to reduce costs while maintaining full compliance and customer satisfaction. A Core Team conducted preliminary evaluations and determined that eight particular aspects of the ORNL waste management program warranted focused investigations during the reengineering. The eight areas included Pollution Prevention, Waste Characterization, Waste Certification/Verification, Hazardous/Mixed Waste Stream, Generator/WM Teaming, Reporting/Records, Disposal End Points, and On-Sitemore » Treatment/Storage. The Core Team commissioned and assembled Process Teams to conduct in-depth evaluations of each of these eight areas. The Core Team then evaluated the Process Team results and consolidated the 80 process-specific recommendations into 15 overall recommendations. Benchmarking of a commercial nuclear facility, a commercial research facility, and a DOE research facility was conducted to both validate the efficacy of these findings and seek additional ideas for improvement. The outcome of this evaluation is represented by the 15 final recommendations that are described in this report.« less
Chen, Maoxia; Fan, Rong; Zou, Wenhui; Zhou, Houzhen; Tan, Zhouliang; Li, Xudong
2016-05-15
A novel bacterial strain BDG-2 was isolated and used to augment the treatment of silicon plate manufacturing wastewater that primarily contains diethylene glycol monobutyl ether (DGBE). BDG-2 was identified as a Serratia sp. Under the optimal conditions of 30 °C, pH 9 and DGBE concentration of 2000 mg L(-1), the bioaugmented system achieved 96.92% COD removal after 39.9h. Laboratory-scale technological matching results indicated that, in a biofilm process with the addition of 100 mg L(-1) ammonia and 5 mg L(-1) total phosphorus (TP), 70.61% COD removal efficiency could be obtained in 46 h. Addition of polyaluminium chloride (PAC) to the reactors during the suspension process enhanced the settleability of the BDG-2 culture. Subsequently, successful start-up and stable operation of a full-scale bioaugmented treatment facilities were accomplished, and the volumetric organic load in the plug-flow aeration tank was 2.17 ± 0.81 kg m(-3) d(-1). The effluent COD of the facilities was stable and always below 100 mg L(-1). Copyright © 2016 Elsevier B.V. All rights reserved.
40 CFR 408.275 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... steamed and canned oyster processing facilities which utilize air flotation treatment systems to meet the....42 pH (1) (1) English units (lb/1,000 lb of product) BOD5 67 17 TSS 56 39 Oil and grease 0.64 0.42 pH...
Impact of coastal processes on resource development with an example from Icy Bay, Alaska
Molnia, Bruce F.
1978-01-01
The coastline of Alaska is dynamic and continually readjusting to changes in the many processes that operate in the coastal zone. Because of this dynamic nature, special consideration must be made in planning for development, and. caution must be exercised in site selection for facilities to be emplaced in the coastal zone. All types of coastal processes from continuously active normal processes to the low frequency-high intensity rare event must be considered. Site-specific evaluation-s considering the broad range of possible processes must precede initiation of development. An example of the relation between coastal processes and a proposed resource treatment facility is presented for Icy Bay, Alaska. Icy Bay is the only sheltered bay near many of the offshore tracts leased for petroleum exploration in the 1976 northern Gulf of Alaska OCS (Outer Continental Shelf) lease sale. Consequently, it has been selected as a primary onshore staging site for the support of offshore exploration and development. The environment of Icy Bay has many potentially hazardous features, including a submarine moraine at the bay mouth and actively calving glaciers at the bay's head which produce many icebergs. But most significant from the point of view of locating onshore facilities and pipeline corridors are the high rates of shoreline erosion and sediment deposition. If pipelines or any onshore staging facilities are to be placed in the coastal areas of Icy Bay, then the dynamic changes in shoreline position must be considered so that man-made structures will not be eroded away or be silted in before the completion of development.
NASA Astrophysics Data System (ADS)
Zaharia, C.
2017-08-01
Nowadays, wastewater (WW) treatment facilities are considered significant exposure pathways for solid particles, and also significant concerns of any quality conscious manufacturer. Most solid particles have some forms of organic coating either used as active material or to suspend and/or stabilize different present solid materials, having increase in toxicity that must be reduced, or sometimes even totally eliminated, especially if effluent is either discharged directly to surface water, or distributed through industrial water supplies. Representatives providing innovative technologies, comprehensive supports and expertise in wastewater and sludge treatment field are known, each one using modern treatment technology and facilities. Mechanical treatment is indispensable in primary treatment steps of both municipal and industrial WW applications, its main goal being separation of floating, settling and suspended materials (especially into a primary sedimentation-based treatment step). The aim of this work is to present comparatively the performance in solids removal of conventional mechanical WW treatment stages, especially those based on primary sedimentation, or sedimentation-like operations applied for Romanian urban WW treatment plants (serving two towns with ca 18,000 inhabitants), industrial WW treatment plants (deserving industries of vegetal food processing and organic chemicals’ manufacturing) and additional information on valorisation of separated solid material and improvement possibilities.
Perceptions of Organizational Functioning in Substance Abuse Treatment Facilities in South Africa
ERIC Educational Resources Information Center
Bowles, Steven; Louw, Johann; Myers, Bronwyn
2011-01-01
Directors' and treatment staff's perceptions of organizational functioning within substance abuse treatment facilities in four provinces in South Africa were examined via the Texas Christian University's Organizational Readiness for Change instrument. Forty-four treatment facilities (out of 89) participated in the study. Results indicated that…
NPDES Permit for Riverview Estates Wastewater Treatment Facility in North Dakota
Under National Pollutant Discharge Elimination System permit number ND-0031143, the Riverview Estates Wastewater Treatment Facility is authorized to discharge from its wastewater treatment facility in designated locations as described in the permit.
Monteith, Hugh D; Sahely, Halla R; MacLean, Heather L; Bagley, David M
2005-01-01
Municipal wastewater treatment may lead to the emission of greenhouse gases. The current Intergovenmental Panel on Climate Change (Geneva, Switzerland) approach attributes only methane emissions to wastewater treatment, but this approach may overestimate greenhouse gas emissions from the highly aerobic processes primarily used in North America. To better estimate greenhouse gas emissions, a procedure is developed that can be used either with plant-specific data or more general regional data. The procedure was evaluated using full-scale data from 16 Canadian wastewater treatment facilities and then applied to all 10 Canadian provinces. The principal greenhouse gas emitted from municipal wastewater treatment plants was estimated to be carbon dioxide (CO2), with very little methane expected. The emission rates ranged from 0.005 kg CO2-equivalent/m3 treated for primary treatment facilities to 0.26 kg CO2-equivalent/m3 for conventional activated sludge, with anaerobic sludge digestion to over 0.8 kg CO2-equivalent/m3 for extended aeration with aerobic digestion. Increasing the effectiveness of biogas generation and use will decrease the greenhouse gas emissions that may be assigned to the wastewater treatment plant.
Capezza, Nicole M; Najavits, Lisa M
2012-04-01
Trauma-informed treatment increasingly is recognized as an important component of service delivery. This study examined differences in treatment-related characteristics of facilities that offer moderate or high levels of trauma-informed counseling versus those that offer no or low levels of such counseling. Responses from 13,223 substance abuse treatment facilities surveyed in 2009 by the National Survey of Substance Abuse Treatment Services (NSSATS) were used. A majority (66.6%) of facilities reported using trauma counseling sometimes or always or often. Facilities that provided moderate or high levels of trauma counseling were more likely to provide additional treatment services, such as disease testing and specialized group therapy, as well as child care, employment counseling, and other ancillary services. A majority of facilities reported provision of trauma counseling. Additional training and resources may be needed for programs that reported low rates of trauma counseling.
Biotreatment from hot bugs to cold ducks
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-02-01
There are few forms of industrial wastes that cannot be neutralized and disposed of using modern treatment methods. The challenge is to control costs and minimize liability. Such is the quandary for waste treatment facilities dealing with biological sludge. One way to reduce sludge volume is to use a high-temperature aerobic treatment process, such as the one recently commercialized by US Filter. The process relies on a strain of bacteria heated to 50--65 C. The high temperatures destroy pathogens and speed metabolism. Cultivated in a lagoon or pond treatment system, the duckweed floats on top of the water and feedsmore » on the organics. The plants consume nitrogen, ammonia and phosphoric compounds, help retain aerobic conditions in the pond, and control algae growth by blocking sunlight.« less
Membrane thickening aerobic digestion processes.
Woo, Bryen
2014-01-01
Sludge management accounts for approximately 60% of the total wastewater treatment plant expenditure and laws for sludge disposal are becoming increasingly stringent, therefore much consideration is required when designing a solids handling process. A membrane thickening aerobic digestion process integrates a controlled aerobic digestion process with pre-thickening waste activated sludge using membrane technology. This process typically features an anoxic tank, an aerated membrane thickener operating in loop with a first-stage digester followed by second-stage digestion. Membrane thickening aerobic digestion processes can handle sludge from any liquid treatment process and is best for facilities obligated to meet low total phosphorus and nitrogen discharge limits. Membrane thickening aerobic digestion processes offer many advantages including: producing a reusable quality permeate with minimal levels of total phosphorus and nitrogen that can be recycled to the head works of a plant, protecting the performance of a biological nutrient removal liquid treatment process without requiring chemical addition, providing reliable thickening up to 4% solids concentration without the use of polymers or attention to decanting, increasing sludge storage capacities in existing tanks, minimizing the footprint of new tanks, reducing disposal costs, and providing Class B stabilization.
Agrest, Martín; Barruti, Silvina; Gabriel, Raquel; Zalazar, Virginia; Wikinski, Silvia; Ardila-Gómez, Sara
2018-02-01
Scarce information is available about how users experience treatment at mental health day hospitals, particularly in South America. To explore users' perspectives about elements of day hospital treatment that facilitate or hinder the recovery process in a mental health facility in Buenos Aires, Argentina. Semi-structured individual interviews (n = 8) and focus groups (n = 4) were carried out with a convenience sample of users of a mental health day hospital program based on a formulation, testing and redevelopment of propositions approach. Results were analyzed through grounded theory techniques. Categories indicating recovery were: starting to do things, being able to see themselves from a new perspective, mood improvement and changes in interpersonal relationships. Aspects facilitating recovery were: activities organized by the facility, the group approach, the care provided by facility workers and the physical environment. Hindering aspects were: heterogeneity of users in terms of age, severity, diagnosis and being underestimated by staff. Being active again was considered to be the main recovery indicator in this cultural context and participating in activities led by skilled facilitators was the most beneficial factor of the program according to the users.
Tsangaratos, P; Kallioras, A; Pizpikis, Th; Vasileiou, E; Ilia, I; Pliakas, F
2017-12-15
Managed Aquifer Recharge is a wide-spread well-established groundwater engineering method which is largely seen as sound and sustainable solution to water scarcity hydrologically sensitive areas, such as the Circum Mediterranean. The process of site selection for the installation of a MAR facility is of paramount importance for the feasibility and effectiveness of the project itself, especially when the facility will include the use of waters of impaired quality as a recharge source, as in the case of Soil-Aquifer-Treatment systems. The main objective of this study is to present the developed framework of a multi-criteria Decision Support System (DSS) that integrates within a dynamic platform the main groundwater engineering parameters associated with MAR applications together with the general geographical features which determine the effectiveness of such a project. The proposed system will provide an advanced coupled DSS-GIS tool capable of handling local MAR-related issues -such as hydrogeology, topography, soil, climate etc., and spatially distributed variables -such as societal, economic, administrative, legislative etc., with special reference to Soil-Aquifer-Treatment technologies. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-11-01
Municipal sanitary landfills generate leachate that New York State regulations require to be collected and treated to avoid contaminating surface water and groundwater. One option for treating leachate is to haul it to municipal wastewater treatment facility. This option may be expensive, may require excessive energy for transportation, and may require pretreatment to protect the receiving facility`s processes. An alternative is on-site treatment and discharge. Personnel from the Town of Fenton, New York; Hawk Engineering, P.C.; Cornell University; and Ithaca College designed, built, and operated a pilot constructed wetland for treating leachate at the Town of Fenton`s municipal landfill. Themore » system, consisting of two overland flow beds and two subsurface flow beds has been effective for 18 months in reducing levels of ammonia (averaging 85% removal by volatilization and denitrification) and total iron (averaging 95% removal by precipitation and sedimentation), two key constituents of the Fenton landfill`s leachate. The system effects these reductions with zero chemical and energy inputs and minimal maintenance. A third key constituent of the leachate, manganese, apparently passes through the beds with minimal removal. Details and wetland considerations are described.« less
Cohn, Amy; Najavits, Lisa M
2014-04-01
Victimization by and perpetration of domestic violence are associated with co-occurring mental and substance use disorders. This study used data from the National Survey of Substance Abuse Treatment Services to examine differences in organizational factors, treatment approaches offered, and client-level factors among 13,342 substance abuse treatment facilities by whether or not they offered domestic violence services. Only 36% of the facilities offered domestic violence services. Those that offered such services were more likely than those that did not to treat clients with co-occurring disorders. Principal-components analysis reduced eight treatment approaches to two factors: psychosocial services and traditional substance abuse services. Regression models indicated that the frequency with which psychosocial services were offered depended on the percentage of clients with co-occurring disorders who were being treated in the facility and whether or not that facility offered domestic violence services. Specifically, facilities that did not offer domestic violence services and that had a high percentage of clients with co-occurring disorders were more likely to offer psychosocial services than facilities that offered domestic violence services. A larger proportion of facilities offering domestic violence services offered traditional substance abuse treatment services, compared with facilities not offering domestic violence services, but this relationship was not contingent on the percentage of clients with co-occurring disorders at each facility. Improved efforts should be made to tailor treatments to accommodate the links between domestic violence, mental disorders, and substance abuse.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SCHAUS, P.S.
At the U.S. Department of Energy (DOE) Hanford Site, the Waste Treatment Plant (WTP) is being constructed to immobilize both high-level waste (IUW) for disposal in a national repository and low-activity waste (LAW) for onsite, near-surface disposal. The schedule-controlling step for the WTP Project is vitrification of the large volume of LAW, current capacity of the WTP (as planned) would require 50 years to treat the Hanford tank waste, if the entire LAW volume were to be processed through the WTP. To reduce the time and cost for treatment of Hanford Tank Waste, and as required by the Tank Wastemore » Remediation System Environmental Impact Statement Record of Decision and the Hanford Federal Facility Consent Agreement (Tn-Party Agreement), DOE plans to supplement the LAW treatment capacity of the WTP. Since 2002, DOE, in cooperation with the Environmental Protection Agency and State of Washington Department of Ecology has been evaluating technologies that could provide safe and effective supplemental treatment of LAW. Current efforts at Hanford are intended to provide additional information to aid a joint agency decision on which technology will be used to supplement the WTP. A Research, Development and Demonstration permit has been issued by the State of Washington to build and (for a limited time) operate a Demonstration Bulk Vitrification System (DBVS) facility to provide information for the decision on a supplemental treatment technology for up to 50% of the LAW. In the Bulk Vitrification (BV) process, LAW, soil, and glass-forming chemicals are mixed, dried, and placed in a refractory-lined box, Electric current, supplied through two graphite electrodes in the box, melts the waste feed, producing a durable glass waste-form. Although recent modifications to the process have resulted in significant improvements, there are continuing technical concerns.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, Kathryn M.L.; Poirier, Michael; McCabe, Daniel J.
The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter,more » so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, Kathryn M. L.; McCabe, Daniel J.; Pareizs, John M.
The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the offgas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter,more » so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.« less
Paz, Concepción; Conde, Marcos; Porteiro, Jacobo; Concheiro, Miguel
2017-01-01
This work introduces the use of machine vision in the massive bubble recognition process, which supports the validation of boiling models involving bubble dynamics, as well as nucleation frequency, active site density and size of the bubbles. The two algorithms presented are meant to be run employing quite standard images of the bubbling process, recorded in general-purpose boiling facilities. The recognition routines are easily adaptable to other facilities if a minimum number of precautions are taken in the setup and in the treatment of the information. Both the side and front projections of subcooled flow-boiling phenomenon over a plain plate are covered. Once all of the intended bubbles have been located in space and time, the proper post-process of the recorded data become capable of tracking each of the recognized bubbles, sketching their trajectories and size evolution, locating the nucleation sites, computing their diameters, and so on. After validating the algorithm’s output against the human eye and data from other researchers, machine vision systems have been demonstrated to be a very valuable option to successfully perform the recognition process, even though the optical analysis of bubbles has not been set as the main goal of the experimental facility. PMID:28632158
Waste Receiving and Processing Facility Module 2A: Advanced Conceptual Design Report. Volume 3A
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Objective of this document is to provide descriptions of all WRAP 2A feed streams, including physical and chemical attributes, and describe the pathway that was used to select data for volume estimates. WRAP 2A is being designed for nonthermal treatment of contact-handled mixed low-level waste Category 1 and 3. It is based on immobilization and encapsulation treatment using grout or polymer.
Ahmad, Riris Andono; Mahendradhata, Yodi; Utarini, Adi; de Vlas, Sake J
2011-04-01
To understand determinants of care-seeking patterns and diagnostic delay amongst tuberculosis (TB) patients diagnosed at direct observed treatment short course (DOTS) facilities in Jogjakarta, Indonesia. Cross-sectional survey amongst newly diagnosed TB patients in 89 DOTS facilities whose history of care-seeking was reconstructed through retrospective interviews gathering data on socio-demographic determinants, onset of TB symptoms, type of health facilities visited, duration of each care-seeking action were recorded. Two hundred and fifty-three TB patients were included in the study whose median duration of patients' delay was 1 week and whose total duration of diagnostic delay was 5.4 weeks. The median number of visits was 4. Many of the patients' socio-demographic determinants were not associated with the care-seeking patterns, and no socio-demographic determinants were associated with the duration of diagnostic delay. More than 60% of TB patients started their care-seeking processes outside DOTS facilities, but the number of visits in DOTS facilities was greater during the overall care-seeking process. Surprisingly, patient's immediate visits to a DOTS facility did not correspond to shorter diagnostic delay. Diagnostic delay in Jogjakarta province was not associated with patients' socio demographic factors, but rather with the health system providing DOTS services. This suggests that strengthening the health system and improving diagnostic quality within DOTS services is now a more rational strategy than expanding the TB programme to engage more providers. © 2010 Blackwell Publishing Ltd.
Comparing the Costs of Military Treatment Facilities with Private Sector Care
2016-02-01
Log: H 15-000527 Comparing the Costs of Military Treatment Facilities with Private Sector Care Philip M. Lurie INSTITUTE FOR DEFENSE ANALYSES 4850 Mark...other national challenges. Comparing the Costs of Military Treatment Facilities with Private Sector Care Philip M. Lurie I N S T I T U T E F O R D...members. The latter benefit, known as TRICARE, serves 9.5 million beneficiaries worldwide, and consists of care in Military Treatment Facilities (MTFs
Biogasification of Walt Disney World biomass waste blend. Annual report, January-December 1983
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biljetina, R.; Chynoweth, D.P.; Janulis, J.
1984-09-01
The objective of this research is to develop efficient processes for conversion of biomass-waste blends to methane and other resources. To evaluate the technical and economic feasibility, an experimental test unit (ETU) was designed and installed at the Reedy Creek Wastewater Treatment Plant at Walt Disney World in Lake Buena Vista, Florida. The facility integrates a biomethanogenic conversion process with a wastewater treatment process employing water hyacinth ponds for secondary and tertiary treatment of sewage. Harvested water hyacinth is subsequently combined with sludge from the primary wastewater clarifier and fed at 1-wet-ton per day to the ETU digester. This resultsmore » in the production of methane and other useful byproducts. Design, procurement of equipment, and installation has been completed. Start-up of the ETU is in progress.« less
Wongtriratanachai, Prasit; Pruksakorn, Dumnoensun; Pothacharoen, Peraphan; Nimkingratana, Puwapong; Pattamapaspong, Nuttaya; Phornphutkul, Chanakarn; Setsitthakun, Sasiwariya; Fongsatitkul, Ladda; Phrompaet, Sureeporn
2013-11-01
Autologous chondrocyte implantation (ACI) has become one of the standard procedures for articular cartilage defect treatment. This technique provides a promising result. However the procedural process requires an approach of several steps from multidisciplinary teams. Although the success of this procedure has been reported from Srinakharinvirot University since 2007, the application of ACI is still limited in Thailand due to the complexity of processes and stringent quality control. This report is to present the first case of the cartilage defect treatment using the first generation-ACI under Chiang Mai University's (CMU) own facility and Ethics Committee. This paper also reviews the process of biotechnology procedures, patient selection, surgical, and rehabilitation techniques. The success of the first case is an important milestone for the further development of the CMU Human Translational Research Laboratory in near future.
Bazargan-Hejazi, Shahrzad; De Lucia, Valory; Pan, Deyu; Mojtahedzadeh, Mona; Rahmani, Elham; Jabori, Sinan; Zahmatkesh, Golara; Bazargan, Mohsen
2016-01-01
Residential treatment for alcoholism is associated with high completion rates for clients, yet there appear to be gender disparities in patient referrals and treatment completion rates. We studied whether (A) gender is associated with differential patient placement to outpatient vs. residential treatment facilities and (B) completion rates differ by gender. In this cross-sectional study, we analyzed the admission and discharge data from 185 publicly funded substance abuse treatment facilities across Los Angeles County between 2005 and 2010. Among the 33,745 studied cases, women were referred to residential treatment facilities less frequently than men (75% vs. 66%). The adjusted results derived from logistic regression models confirmed that females were more likely to be referred to outpatient treatment than to residential treatment facilities (odds ratio [OR]: 1.15, 95% confidence interval [CI]: 1.05-1.26). In addition, we observed that compared to White/Caucasian patients, all other races were associated with more referral to outpatient facilities (ie, less referral to residential facilities), indicating a racial disparity on the top of the observed gender disparity. However, there was no significant link between gender and treatment completion rates (OR: 0.93, 95% CI: 0.86-1.00). Women seem to have treatment completion rates comparable to men, yet they are less likely to be referred to residential treatment facilities. Hence, there still remains a gender disparity in alcoholic patient referrals. Further studies should delineate which specific therapeutic aspects and programmatic components of women-focused treatments are essential to augment positive treatment outcomes.
Provision of Mental Health Services in South African Substance Abuse Treatment Facilities
ERIC Educational Resources Information Center
Myers, Bronwyn; Fakier, Nuraan
2009-01-01
To date, South African research has not examined mental health service provision in substance abuse treatment facilities, even though these services improve client retention and treatment outcomes. To describe the extent to which substance abuse treatment facilities in Gauteng and KwaZulu-Natal provinces provide clients with mental health services…
24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...
24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...
24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...
24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...
24 CFR 960.205 - Drug use by applicants: Obtaining information from drug treatment facility.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... This section addresses a PHA's authority to request and obtain information from drug abuse treatment... household member. (2) Drug abuse treatment facility. An entity: (i) That holds itself out as providing, and... consent forms signed by such household member that: (i) Requests any drug abuse treatment facility to...
Wen, Hefei; Cummings, Janet R; Hockenberry, Jason M; Gaydos, Laura M; Druss, Benjamin G
2013-12-01
The passage of the 2008 Mental Health Parity and Addiction Equity Act and the 2010 Affordable Care Act incorporated parity for substance use disorder (SUD) treatment into federal legislation. However, prior research provides us with scant evidence as to whether federal parity legislation will hold the potential for improving access to SUD treatment. To examine the effect of state-level SUD parity laws on state-aggregate SUD treatment rates and to shed light on the impact of the recent federal SUD parity legislation. We conducted a quasi-experimental study using a 2-way (state and year) fixed-effect method. We included all known specialty SUD treatment facilities in the United States and examined treatment rates from October 1, 2000, through March 31, 2008. Our main source of data was the National Survey of Substance Abuse Treatment Services, which provides facility-level information on specialty SUD treatment. State-level SUD parity laws during the study period. State-aggregate SUD treatment rates in (1) all specialty SUD treatment facilities and (2) specialty SUD treatment facilities accepting private insurance. The implementation of any SUD parity law increased the treatment rate by 9% (P < .001) in all specialty SUD treatment facilities and by 15% (P = .02) in facilities accepting private insurance. Full parity and parity only if SUD coverage is offered increased the SUD treatment rate by 13% (P = .02) and 8% (P = .04), respectively, in all facilities and by 21% (P = .03) and 10% (P = .04), respectively, in facilities accepting private insurance. We found a positive effect of the implementation of state SUD parity legislation on access to specialty SUD treatment. Furthermore, the positive association is more pronounced in states with more comprehensive parity laws. Our findings suggest that federal parity legislation holds the potential to improve access to SUD treatment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the Use of Restraint or Seclusion in Psychiatric Residential Treatment Facilities Providing Inpatient... effect of restricting the resident's freedom of movement; and (3) Is not a standard treatment for the... another. Psychiatric Residential Treatment Facility means a facility other than a hospital, that provides...
The Impact of In-Prison Therapeutic Community Programs on Prison Management.
ERIC Educational Resources Information Center
Prendergast, Michael; Farabee, David; Cartier, Jerome
2001-01-01
Presents findings of a process evaluation of the California Substance Abuse Treatment Facility. Measures from the evaluation suggest that the presence of a therapeutic community within a prison is associated with significant advantages for management of the institution-including lower rates of infractions, reduced absenteeism among correctional…
Signal processing techniques were applied to high-resolution time series data obtained from conductivity loggers placed upstream and downstream of a wastewater treatment facility along a river. Data was collected over 14-60 days, and several seasons. The power spectral densit...
40 CFR 440.132 - General definitions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... facility. (e) “In-situ leach methods” means the processes involving the purposeful introduction of suitable... mines, any area of land on or in which grading has been completed to return the earth to desired contour... equivalent regional rainfall and evaporation data. (c) “Appropriate treatment of the recycle water” in...
40 CFR 440.132 - General definitions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... facility. (e) “In-situ leach methods” means the processes involving the purposeful introduction of suitable... mines, any area of land on or in which grading has been completed to return the earth to desired contour... equivalent regional rainfall and evaporation data. (c) “Appropriate treatment of the recycle water” in...
40 CFR 440.132 - General definitions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... facility. (e) “In-situ leach methods” means the processes involving the purposeful introduction of suitable... mines, any area of land on or in which grading has been completed to return the earth to desired contour... equivalent regional rainfall and evaporation data. (c) “Appropriate treatment of the recycle water” in...
Cupertino, A Paula; Hunt, Jamie J; Gajewski, Byron J; Jiang, Yu; Marquis, Janet; Friedmann, Peter D; Engelman, Kimberly K; Richter, Kimber P
2013-03-15
Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1-5) and the ITTQ displayed good internal consistency (Cronbach's alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change.
2013-01-01
Background Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). Methods We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Results Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1–5) and the ITTQ displayed good internal consistency (Cronbach’s alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. Conclusions The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change. PMID:23497366
Supplemental Immobilization of Hanford Low-Activity Waste: Cast Stone Screening Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Westsik, Joseph H.; Piepel, Gregory F.; Lindberg, Michael J.
2013-09-30
More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in themore » HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second LAW immobilization facility will be needed for the expected volume of LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with the waste acceptance criteria for the disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long-term performance of the waste form in the disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF. The PA is needed to satisfy both Washington State IDF Permit and DOE Order requirements. Cast Stone has been selected for solidification of radioactive wastes including WTP aqueous secondary wastes treated at the Effluent Treatment Facility (ETF) at Hanford. A similar waste form called Saltstone is used at the Savannah River Site (SRS) to solidify its LAW tank wastes.« less
Finding agreement to limit life-sustaining treatment for children who are in state custody.
Savage, T; Michalak, D R
2001-01-01
For children in state custody with extensive disabilities who reside in a skilled nursing facility, it is possible and, at times, desirable to limit treatment in the form of withholding resuscitation. With demonstration and documentation of the benefits and burdens of resuscitation for a particular child, the child protection agency will authorize a "Do Not Resuscitate" order. This article discusses the procedural as well as ethical issues involved in the process of finding agreement to limit life-sustaining treatment for children who are in state custody.
Weirich, Scott R; Silverstein, Joann; Rajagopalan, Balaji
2011-08-01
There is increasing interest in decentralization of wastewater collection and treatment systems. However, there have been no systematic studies of the performance of small treatment facilities compared with larger plants. A statistical analysis of 4 years of discharge monthly report (DMR) data from 210 operating wastewater treatment facilities was conducted to determine the effect of average flow rate and capacity utilization on effluent biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia, and fecal coliforms relative to permitted values. Relationships were quantified using generalized linear models (GLMs). Small facilities (40 m³/d) had violation rates greater than 10 times that of the largest facilities (400,000 m³/d) for BOD, TSS, and ammonia. For facilities with average flows less than 40,000 m³/d, increasing capacity utilization was correlated with increased effluent levels of BOD and TSS. Larger facilities tended to operate at flows closer to their design capacity while maintaining treatment suggesting greater efficiency. Copyright © 2011 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
S. Frank
The current method for the immobilization of fission products that accumulate in electrorefiner salt during the electrochemical processing of used metallic nuclear fuel is to encapsulate the electrorefiner salt in a glass-bonded sodalite ceramic waste form. This process was developed by Argonne National Laboratory in the USA and is currently performed at the Idaho National Laboratory for the treatment of Experimental Breeder Reactor-II (EBR-II) used fuel. This process utilizes a “once-through” option for the disposal of spent electrorefiner salt; where, after the treatment of the EBR-II fuel, the electrorefiner salt containing the active fission products will be disposed of inmore » the ceramic waste form (CWF). The CWF produced will have low fission product loading of approximately 2 to 5 weight percent due to the limited fuel inventory currently being processed. However; the design and implementation of advanced electrochemical processing facilities to treat used fuel would process much greater quantities fuel. With an advanced processing facility, it would be necessary to selectively remove fission products from the electrorefiner salt for salt recycle and to concentrate the fission products to reduce the volume of high-level waste from the treatment facility. The Korean Atomic Energy Research Institute and the Idaho National Laboratory have been collaborating on I-NERI research projects for a number of years to investigate both aspects of selective fission product separation from electrorefiner salt, and to develop advanced waste forms for the immobilization of the collected fission products. The first joint KAERI/INL I-NERI project titled: 2006-002-K, Separation of Fission Products from Molten LiCl-KCl Salt Used for Electrorefining of Metal Fuels, was successfully completed in 2009 by concentrating and isolating fission products from actual electrorefiner salt used for the treated used EBR-II fuel. Two separation methods were tested and from these tests were produced concentrated salt products that acted as the feed material for development of advanced waste forms investigated in this proposal. Accomplishments from the first year activities associated with this I-NERI project included the down selection of candidate waste forms to immobilize fission products separated from electrorefiner salt, and the design of equipment to fabricate actual waste forms in the Hot Fuels Examination Facility (HFEF) at the INL. Reported in this document are accomplishments from the second year (FY10) work performed at the INL, and includes the testing of waste form fabrication equipment, repeating the fission product precipitation experiment, and initial waste form fabrication efforts.« less
Draft Site Treatment Plan (DSTP), Volumes I and II
DOE Office of Scientific and Technical Information (OSTI.GOV)
D`Amelio, J.
1994-08-30
Site Treatment Plans (STP) are required for facilities at which the DOE generates or stores mixed waste. This Draft Site Treatment Plan (DSTP) the second step in a three-phase process, identifies the currently preferred options for treating mixed waste at the Savannah River Site (SRS) or for developing treatment technologies where technologies do not exist or need modification. The DSTP reflects site-specific preferred options, developed with the state`s input and based on existing available information. To the extent possible, the DSTP identifies specific treatment facilities for treating the mixed waste and proposes schedules. Where the selection of specific treatment facilitiesmore » is not possible, schedules for alternative activities such as waste characterization and technology assessment are provided. All schedule and cost information presented is preliminary and is subject to change. The DSTP is comprised of two volumes: this Compliance Plan Volume and the Background Volume. This Compliance Plan Volume proposes overall schedules with target dates for achieving compliance with the land disposal restrictions (LDR) of RCRA and procedures for converting the target dates into milestones to be enforced under the Order. The more detailed discussion of the options contained in the Background Volume is provided for informational purposes only.« less
Molinos-Senante, M; Garrido-Baserba, M; Reif, R; Hernández-Sancho, F; Poch, M
2012-06-15
The preliminary design and economic assessment of small wastewater treatment plants (less than 2000 population equivalent) are issues of particular interest since wastewaters from most of these agglomerations are not covered yet. This work aims to assess nine different technologies set-up for the secondary treatment in such type of facilities embracing both economic and environmental parameters. The main novelty of this work is the combination of an innovative environmental decision support system (EDSS) with a pioneer approach based on the inclusion of the environmental benefits derived from wastewater treatment. The integration of methodologies based on cost-benefit analysis tools with the vast amount of knowledge from treatment technologies contained in the EDSS was applied in nine scenarios comprising different wastewater characteristics and reuse options. Hence, a useful economic feasibility indicator is obtained for each technology including internal and external costs and, for the first time, benefits associated with the environmental damage avoided. This new methodology proved to be crucial for supporting the decision process, contributing to improve the sustainability of new treatment facilities and allows the selection of the most feasible technologies of a wide set of possibilities. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorries, Alison M
2010-11-09
Facing the closure of nearly all on-site management and disposal capability for low-level radioactive waste (LLW), Los Alamos National Laboratory (LANL) is making ready to ship the majority of LLW off-site. In order to ship off-site, waste must meet the Treatment, Storage, and Disposal Facility's (TSDF) Waste Acceptance Criteria (WAC). In preparation, LANL's waste management organization must ensure LANL waste generators characterize and package waste compliantly and waste characterization documentation is complete and accurate. Key challenges that must be addressed to successfully make the shift to off-site disposal of LLW include improving the detail, accuracy, and quality of process knowledgemore » (PK) and acceptable knowledge (AK) documentation, training waste generators and waste management staff on the higher standard of data quality and expectations, improved WAC compliance for off-site facilities, and enhanced quality assurance throughout the process. Certification of LANL generators will allow direct off-site shipping of LLW from their facilities.« less
Factors affecting the availability and use of hemodialysis facilities.
Cleary, P D; Schlesinger, M; Blumenthal, D
1991-01-01
This article describes factors related to the geographic distribution of hemodialysis facilities and the relationship between availability and use. Such facilities tend to be concentrated in the same types of areas as other medical resources, and the number of medical specialists in an area is related to the rate of treatment for renal diseases. The proportion of treatment stations in an area owned by for-profit organizations is not related to the total treatment rate, but the market share of for-profit facilities is positively related to in-center treatment and negatively related to home treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyle, C.A.; Baetz, B.W.
1998-09-01
A knowledge-based decision support system (KBDSS) has been developed to examine the potentials for reuse, co-treatment, recycling and disposal of wastes from different industrial facilities. Four plants on the Point Lisas Industrial Estate in Trinidad were selected to test this KBDSS; a gas processing plant, a methanol plant, a fertilizer/ammonia plant and a steel processing plant. A total of 77 wastes were produced by the plants (51,481,500 t year{sup {minus}1}) with the majority being released into the ocean or emitted into the air. Seventeen wastes were already being recycled off-site so were not included in the database. Using a knowledgemore » base of 25 possible treatment processes, the KBDSS generated over 4,600 treatment train options for managing the plant wastes. The developed system was able to determine treatment options for the wastes which would minimize the number of treatments and the amount of secondary wastes produced and maximize the potential for reuse, recycling and co-treatment of wastes.« less
Medical Image Analysis Facility
NASA Technical Reports Server (NTRS)
1978-01-01
To improve the quality of photos sent to Earth by unmanned spacecraft. NASA's Jet Propulsion Laboratory (JPL) developed a computerized image enhancement process that brings out detail not visible in the basic photo. JPL is now applying this technology to biomedical research in its Medical lrnage Analysis Facility, which employs computer enhancement techniques to analyze x-ray films of internal organs, such as the heart and lung. A major objective is study of the effects of I stress on persons with heart disease. In animal tests, computerized image processing is being used to study coronary artery lesions and the degree to which they reduce arterial blood flow when stress is applied. The photos illustrate the enhancement process. The upper picture is an x-ray photo in which the artery (dotted line) is barely discernible; in the post-enhancement photo at right, the whole artery and the lesions along its wall are clearly visible. The Medical lrnage Analysis Facility offers a faster means of studying the effects of complex coronary lesions in humans, and the research now being conducted on animals is expected to have important application to diagnosis and treatment of human coronary disease. Other uses of the facility's image processing capability include analysis of muscle biopsy and pap smear specimens, and study of the microscopic structure of fibroprotein in the human lung. Working with JPL on experiments are NASA's Ames Research Center, the University of Southern California School of Medicine, and Rancho Los Amigos Hospital, Downey, California.
García Cañas, Rafael; Navarro Suay, R
2017-12-01
Operation 'Inherent Resolve' was approved by the United Nations in August 2014 with the objective of suppressing the Islamic State in Iraq and the Levant and increasing the region's stability. The mission of the Spanish military forces within this was to direct training missions for the Iraqi Army. The aim of this study is to analyse the medical care provided in the Spanish Role 1 deployed medical treatment facility during Operation 'Apoyo a Irak'. A cross-sectional, descriptive and retrospective study was conducted between 15 December 2015 and 18 November 2016. The study population comprised all personnel treated at the Spanish Role 1 medical treatment facility of the 'Gran Capitan' base in Besmaya, Iraq. During the study period, a total of 2208 consultations were performed, 1547 of which were first consultations. The predominant type of medical care was categorised as 'traumatology' (n=438; 19.8%), followed by 'healing of wounds and minor surgical processes' (n=332; 15%), 'acute upper respiratory tract infections' (n=267; 12%), 'dermatology' (n=214; 9.6%) and 'gastroenterology' (n=214; 9.6%). Twenty-eight patients (1.2%) required care in the upper medical echelon of care, three of whom were urgently evacuated. Oral diseases were the main reason for evacuation to the next medical echelon. Four patients were repatriated to the national territory for medical reasons. One death was recorded due to a vehicle accident. The results of our study reinforce those found in similar recent international missions in which the Spanish Armed Forces and other allied armies have deployed a Role 1 medical treatment facility. Military physicians deploying on operations such as Iraq should have up-to-date training in emergency and primary care medicine, with special emphasis on basic trauma knowledge and performing minor surgical processes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Diamantis, Vasileios; Erguder, Tuba H; Aivasidis, Alexandros; Verstraete, Willy; Voudrias, Evangelos
2013-10-15
The present paper focuses on a largely unexplored field of landfill-site valorization in combination with the construction and operation of a centralized olive mill wastewater (OMW) treatment facility. The latter consists of a wastewater storage lagoon, a compact anaerobic digester operated all year round and a landfill-based final disposal system. Key elements for process design, such as wastewater pre-treatment, application method and rate, and the potential effects on leachate quantity and quality, are discussed based on a comprehensive literature review. Furthermore, a case-study for eight (8) olive mill enterprises generating 8700 m(3) of wastewater per year, was conceptually designed in order to calculate the capital and operational costs of the facility (transportation, storage, treatment, final disposal). The proposed facility was found to be economically self-sufficient, as long as the transportation costs of the OMW were maintained at ≤4.0 €/m(3). Despite that EU Landfill Directive prohibits wastewater disposal to landfills, controlled application, based on appropriately designed pre-treatment system and specific loading rates, may provide improved landfill stabilization and a sustainable (environmentally and economically) solution for effluents generated by numerous small- and medium-size olive mill enterprises dispersed in the Mediterranean region. Copyright © 2013 Elsevier Ltd. All rights reserved.
WASTE TREATMENT PLANT (WTP) LIQUID EFFLUENT TREATABILITY EVALUATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
LUECK, K.J.
2004-10-18
A forecast of the radioactive, dangerous liquid effluents expected to be produced by the Waste Treatment Plant (WTP) was provided by Bechtel National, Inc. (BNI 2004). The forecast represents the liquid effluents generated from the processing of Tank Farm waste through the end-of-mission for the WTP. The WTP forecast is provided in the Appendices. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Both facilities are located in the 200 East Area and are operated by Fluor Hanford, Inc. (FH) for the US. Department ofmore » Energy (DOE). The treatability of the WTP liquid effluents in the LERF/ETF was evaluated. The evaluation was conducted by comparing the forecast to the LERF/ETF treatability envelope (Aromi 1997), which provides information on the items which determine if a liquid effluent is acceptable for receipt and treatment at the LERF/ETF. The format of the evaluation corresponds directly to the outline of the treatability envelope document. Except where noted, the maximum annual average concentrations over the range of the 27 year forecast was evaluated against the treatability envelope. This is an acceptable approach because the volume capacity in the LERF Basin will equalize the minimum and maximum peaks. Background information on the LERF/ETF design basis is provided in the treatability envelope document.« less
40 CFR 440.14 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Lisa; Lekov, Alex; McKane, Aimee
2010-08-20
This case study enhances the understanding of open automated demand response opportunities in municipal wastewater treatment facilities. The report summarizes the findings of a 100 day submetering project at the San Luis Rey Wastewater Treatment Plant, a municipal wastewater treatment facility in Oceanside, California. The report reveals that key energy-intensive equipment such as pumps and centrifuges can be targeted for large load reductions. Demand response tests on the effluent pumps resulted a 300 kW load reduction and tests on centrifuges resulted in a 40 kW load reduction. Although tests on the facility?s blowers resulted in peak period load reductions ofmore » 78 kW sharp, short-lived increases in the turbidity of the wastewater effluent were experienced within 24 hours of the test. The results of these tests, which were conducted on blowers without variable speed drive capability, would not be acceptable and warrant further study. This study finds that wastewater treatment facilities have significant open automated demand response potential. However, limiting factors to implementing demand response are the reaction of effluent turbidity to reduced aeration load, along with the cogeneration capabilities of municipal facilities, including existing power purchase agreements and utility receptiveness to purchasing electricity from cogeneration facilities.« less
Systems Analyze Water Quality in Real Time
NASA Technical Reports Server (NTRS)
2010-01-01
A water analyzer developed under Small Business Innovation Research (SBIR) contracts with Kennedy Space Center now monitors treatment processes at water and wastewater facilities around the world. Originally designed to provide real-time detection of nutrient levels in hydroponic solutions for growing plants in space, the ChemScan analyzer, produced by ASA Analytics Inc., of Waukesha, Wisconsin, utilizes spectrometry and chemometric algorithms to automatically analyze multiple parameters in the water treatment process with little need for maintenance, calibration, or operator intervention. The company has experienced a compound annual growth rate of 40 percent over its 15-year history as a direct result of the technology's success.
Pecson, Brian M; Triolo, Sarah C; Olivieri, Simon; Chen, Elise C; Pisarenko, Aleksey N; Yang, Chao-Chun; Olivieri, Adam; Haas, Charles N; Trussell, R Shane; Trussell, R Rhodes
2017-10-01
To safely progress toward direct potable reuse (DPR), it is essential to ensure that DPR systems can provide public health protection equivalent to or greater than that of conventional drinking water sources. This study collected data over a one-year period from a full-scale DPR demonstration facility, and used both performance distribution functions (PDFs) and quantitative microbial risk assessment (QMRA) to define and evaluate the reliability of the advanced water treatment facility (AWTF). The AWTF's ability to control enterovirus, Giardia, and Cryptosporidium was characterized using online monitoring of surrogates in a treatment train consisting of ozone, biological activated carbon, microfiltration, reverse osmosis, and ultraviolet light with an advanced oxidation process. This process train was selected to improve reliability by providing redundancy, defined as the provision of treatment beyond the minimum needed to meet regulatory requirements. The PDFs demonstrated treatment that consistently exceeded the 12/10/10-log thresholds for virus, Giardia, and Cryptosporidium, as currently required for potable reuse in California (via groundwater recharge and surface water augmentation). Because no critical process failures impacted pathogen removal performance during the yearlong testing, hypothetical failures were incorporated into the analysis to understand the benefit of treatment redundancy on performance. Each unit process was modeled with a single failure per year lasting four different failure durations: 15 min, 60 min, 8 h, and 24 h. QMRA was used to quantify the impact of failures on pathogen risk. The median annual risk of infection for Cryptosporidium was 4.9 × 10 -11 in the absence of failures, and reached a maximum of 1.1 × 10 -5 assuming one 24-h failure per process per year. With the inclusion of free chlorine disinfection as part of the treatment process, enterovirus had a median annual infection risk of 1.5 × 10 -14 (no failures) and a maximum annual value of 2.1 × 10 -5 (assuming one 24-h failure per year). Even with conservative failure assumptions, pathogen risk from this treatment train remains below the risk targets for both the U.S. (10 -4 infections/person/year) and the WHO (approximately 10 -3 infections/person/year, equivalent to 10 -6 DALY/person/year), demonstrating the value of a failure prevention strategy based on treatment redundancy. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Region 9 NPDES Facilities - Waste Water Treatment Plants
Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.
Carey, Evan P; Nolan, Charlotte; Kerns, Robert D; Ho, P Michael; Frank, Joseph W
2018-05-01
Expert guidelines recommend non-pharmacologic treatments and non-opioid medications for chronic pain and recommend against initiating long-term opioid therapy (LTOT). We examined whether veterans with incident chronic pain receiving care at facilities with greater utilization of non-pharmacologic treatments and non-opioid medications are less likely to initiate LTOT. Retrospective cohort study PARTICIPANTS: Veterans receiving primary care from a Veterans Health Administration facility with incident chronic pain between 1/1/2010 and 12/31/2015 based on either of 2 criteria: (1) persistent moderate-to-severe patient-reported pain and (2) diagnoses "likely to represent" chronic pain. The independent variable was facility-level utilization of pain-related treatment modalities (non-pharmacologic, non-opioid medications, LTOT) in the prior calendar year. The dependent variable was patient-level initiation of LTOT (≥ 90 days within 365 days) in the subsequent year, adjusting for patient characteristics. Among 1,094,569 veterans with incident chronic pain from 2010 to 2015, there was wide facility-level variation in utilization of 10 pain-related treatment modalities, including initiation of LTOT (median, 16%; range, 5-32%). Veterans receiving care at facilities with greater utilization of non-pharmacologic treatments were less likely to initiate LTOT in the year following incident chronic pain. Conversely, veterans receiving care at facilities with greater non-opioid and opioid medication utilization were more likely to initiate LTOT; this association was strongest for past year facility-level LTOT initiation (adjusted rate ratio, 2.10; 95% confidence interval, 2.06-2.15, top vs. bottom quartile of facility-level LTOT initiation in prior calendar year). Facility-level utilization patterns of non-pharmacologic, non-opioid, and opioid treatments for chronic pain are associated with subsequent patient-level initiation of LTOT among veterans with incident chronic pain. Further studies should seek to understand facility-level variation in chronic pain care and to identify facility-level utilization patterns that are associated with improved patient outcomes.
Depleted uranium startup of spent-fuel treatment operations at ANL-West
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goff, K.M.; Mariani, R.D.; Bonomo, N.L.
1995-12-31
At Argonne National Laboratory-West (ANL-West) there are several thousand kilograms of Experimental Breeder Reactor II (EBR-II) spent nuclear fuel. This fuel will be treated using an electrometallurgical process in the fuel conditioning facility (FCF) at ANL-West to produce stable waste forms for storage and disposal. The process equipment is undergoing testing with depleted uranium in preparation for irradiated fuel operations during the summer of 1995.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCabe, Daniel J.; Wilmarth, William R.; Nash, Charles A.
2013-08-29
The purpose of this Process Development Plan is to summarize the objectives and plans for the technology development activities for an alternative path for disposition of the recycle stream that will be generated in the Hanford Waste Treatment Plant Low Activity Waste (LAW) vitrification facility (LAW Recycle). This plan covers the first phase of the development activities. The baseline plan for disposition of this stream is to recycle it to the WTP Pretreatment Facility, where it will be concentrated by evaporation and returned to the LAW vitrification facility. Because this stream contains components that are volatile at melter temperatures andmore » are also problematic for the glass waste form, they accumulate in the Recycle stream, exacerbating their impact on the number of LAW glass containers. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and reducing the halides in the Recycle is a key component of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, this stream does not have a proven disposition path, and resolving this gap becomes vitally important. This task seeks to examine the impact of potential future disposition of this stream in the Hanford tank farms, and to develop a process that will remove radionuclides from this stream and allow its diversion to another disposition path, greatly decreasing the LAW vitrification mission duration and quantity of glass waste. The origin of this LAW Recycle stream will be from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover or precipitates of scrubbed components (e.g. carbonates). The soluble components are mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet, and will not be available until the WTP begins operation, causing uncertainty in its composition, particularly the radionuclide content. This plan will provide an estimate of the likely composition and the basis for it, assess likely treatment technologies, identify potential disposition paths, establish target treatment limits, and recommend the testing needed to show feasibility. Two primary disposition options are proposed for investigation, one is concentration for storage in the tank farms, and the other is treatment prior to disposition in the Effluent Treatment Facility. One of the radionuclides that is volatile and expected to be in high concentration in this LAW Recycle stream is Technetium-99 ({sup 99}Tc), a long-lived radionuclide with a half-life of 210,000 years. Technetium will not be removed from the aqueous waste in the Hanford Waste Treatment and Immobilization Plant (WTP), and will primarily end up immobilized in the LAW glass, which will be disposed in the Integrated Disposal Facility (IDF). Because {sup 99}Tc has a very long half-life and is highly mobile, it is the largest dose contributor to the Performance Assessment (PA) of the IDF. Other radionuclides that are also expected to be in appreciable concentration in the LAW Recycle are {sup 129}I, {sup 90}Sr, {sup 137}Cs, and {sup 241}Am. The concentrations of these radionuclides in this stream will be much lower than in the LAW, but they will still be higher than limits for some of the other disposition pathways currently available. Although the baseline process will recycle this stream to the Pretreatment Facility, if the LAW facility begins operation first, this stream will not have a disposition path internal to WTP. One potential solution is to return the stream to the tank farms where it can be evaporated in the 242-A evaporator, or perhaps deploy an auxiliary evaporator to concentrate it prior to return to the tank farms. In either case, testing is needed to evaluate if this stream is compatible with the evaporator and the other wastes in the tank farm. It should be noted that prior experience in evaporation of another melter off-gas stream, the Recycle Stream at the SRS Defense Waste Processing Facility, unexpectedly caused deleterious impacts on evaporator scaling and formation of aluminosilicate solids before controls were implemented. The compatibility of this stream with other wastes and components in the tank farms has not been fully investigated, whether it is sent for storage in AW-102 in preparation for evaporation in 242-A evaporator, or if it is pre-concentrated in an auxiliary evaporator. This stream is expected to be unusual because it will be very high in corrosive species that are volatile in the melter (chloride, fluoride, sulfur), will have high ammonia, and will contain carryover particulates of glass-former chemicals. These species have potential to cause corrosion, precipitation, flammable gases, and scale in the tank farm system. Testing is needed to demonstrate acceptable conditions and limits for these compounds in wastes sent to the tank farms. Alternate disposition of this LAW Recycle stream could beneficially impact WTP, and may also remove a sizeable fraction of the 99Tc from the source term at the IDF. The alternative radionuclide removal process envisioned for this stream parallels the Actinide Removal Process that has been successfully used at SRS for several years. In that process, Monosodium Titanate (MST) is added to the tank waste to adsorb 90Sr and actinides, and then the MST and radionuclides are removed by filtration. The process proposed for investigation for the Hanford WTP LAW Recycle stream would similarly add MST to remove 90Sr and actinides, along with other absorbents or precipitating agents for the remaining radionuclides. These include inorganic reducing agents for Tc, and zeolites for 137Cs. After treatment, disposition of the decontaminated Recycle stream may be suitable for the Effluent Treatment Facility, where it could be evaporated and solidified. The contaminated slurry stream containing the absorbents and radionuclides will be preliminarily characterized in this phase of the program to evaluate disposal options, and disposition routes will be tested in the next phase. The testing described herein will aid in selection of the best disposal pathway. Several research tasks have been identified that are needed for this initial phase: imulant formulation- Concentration of Recycle to reduce storage volume; Blending of concentrated Recycle with tank waste; Sorption of radionuclides; Precipitation of radionuclides. After this initial phase of testing, additional tasks are expected to be identified for development. These tasks likely include evaluation and testing of applicable solid-liquid separation technologies, slurry rheology measurements, composition variability testing and evaluations, corrosion and erosion testing, slurry storage and immobilization investigations, and decontaminated Recycle evaporation and solidification. Although there are a number of unknown parameters listed in the technical details of the concepts described here, many of these parameters have precedence and do not generally require fundamental new scientific breakthroughs. Many of the materials and processes described are already used in radioactive applications in the DOE complex, or have been tested previously in comparable conditions. Some of these materials and equipment are already used in High Level Waste applications, which are much more complex and aggressive conditions than the LAW Recycle stream. In some cases, the unknown parameters are simply extensions of already studied conditions, such as tank waste corrosion chemistry. The list of testing needs at first appears daunting, but virtually all have been done before, although there are potential issues with compatibility with this unique waste stream. It is anticipated that the challenge will be more in integrating the system and complying with process limitations than in developing entirely new technologies. Several assumptions have been made in this document about the acceptability of radionuclide decontamination and potential waste forms for disposal. These assumptions have been used to define acceptability criteria for feasibility studies on removal. These limits are not intended to define regulatory or facility limits, but rather provide a starting point for evaluating various technologies.« less
3718-F Alkali Metal Treatment and Storage Facility Closure Plan. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
The Hanford Site, located northwest of the city of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials, as well as for activities associated with nuclear energy development. The 300 Area of the Hanford Site contains reactor fuel manufacturing facilities and several research and development laboratories. The 3718-F Alkali Metal Treatment and Storage Facility (3718-F Facility), located in the 300 Area, was used to store and treat alkali metal wastes. Therefore, it is subject to the regulatory requirements for the storage and treatment of dangerous wastes. Closure will be conducted pursuant tomore » the requirements of the Washington Administrative Code (WAC) 173-303-610 (Ecology 1989) and 40 CFR 270.1. Closure also will satisfy the thermal treatment facility closure requirements of 40 CFR 265.381. This closure plan presents a description of the 3718-F Facility, the history of wastes managed, and the approach that will be followed to close the facility. Only hazardous constituents derived from 3718-F Facility operations will be addressed.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... other community-based treatment facilities, when considered to be medically advantageous and cost... dependence or abuse treatment and rehabilitation in residential and nonresidential facilities by contract. 17... rehabilitation in residential and nonresidential facilities by contract. (a) Alcohol and drug dependence or abuse...
Code of Federal Regulations, 2010 CFR
2010-07-01
... annual precipitation falling on the treatment facility and the drainage area contributing surface runoff... difference between annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility and annual evaporation may be discharged subject to the...
40 CFR 440.44 - New source performance standards (NSPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... December 3, 1982. (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility...
7 CFR 305.15 - Treatment requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 5 2010-01-01 2010-01-01 false Treatment requirements. 305.15 Section 305.15... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS Cold Treatments § 305.15 Treatment requirements. (a) Approval of treatment facilities. All facilities or locations used for refrigerating fruits...
Tagar, Elya; Sundaram, Maaya; Condliffe, Kate; Matatiyo, Blackson; Chimbwandira, Frank; Chilima, Ben; Mwanamanga, Robert; Moyo, Crispin; Chitah, Bona Mukosha; Nyemazi, Jean Pierre; Assefa, Yibeltal; Pillay, Yogan; Mayer, Sam; Shear, Lauren; Dain, Mary; Hurley, Raphael; Kumar, Ritu; McCarthy, Thomas; Batra, Parul; Gwinnell, Dan; Diamond, Samantha; Over, Mead
2014-01-01
Today's uncertain HIV funding landscape threatens to slow progress towards treatment goals. Understanding the costs of antiretroviral therapy (ART) will be essential for governments to make informed policy decisions about the pace of scale-up under the 2013 WHO HIV Treatment Guidelines, which increase the number of people eligible for treatment from 17.6 million to 28.6 million. The study presented here is one of the largest of its kind and the first to describe the facility-level cost of ART in a random sample of facilities in Ethiopia, Malawi, Rwanda, South Africa and Zambia. In 2010-2011, comprehensive data on one year of facility-level ART costs and patient outcomes were collected from 161 facilities, selected using stratified random sampling. Overall, facility-level ART costs were significantly lower than expected in four of the five countries, with a simple average of $208 per patient-year (ppy) across Ethiopia, Malawi, Rwanda and Zambia. Costs were higher in South Africa, at $682 ppy. This included medications, laboratory services, direct and indirect personnel, patient support, equipment and administrative services. Facilities demonstrated the ability to retain patients alive and on treatment at these costs, although outcomes for established patients (2-8% annual loss to follow-up or death) were better than outcomes for new patients in their first year of ART (77-95% alive and on treatment). This study illustrated that the facility-level costs of ART are lower than previously understood in these five countries. While limitations must be considered, and costs will vary across countries, this suggests that expanded treatment coverage may be affordable. Further research is needed to understand investment costs of treatment scale-up, non-facility costs and opportunities for more efficient resource allocation.
Process development for scum to biodiesel conversion.
Bi, Chong-hao; Min, Min; Nie, Yong; Xie, Qing-long; Lu, Qian; Deng, Xiang-yuan; Anderson, Erik; Li, Dong; Chen, Paul; Ruan, Roger
2015-06-01
A novel process was developed for converting scum, a waste material from wastewater treatment facilities, to biodiesel. Scum is an oily waste that was skimmed from the surface of primary and secondary settling tanks in wastewater treatment plants. Currently scum is treated either by anaerobic digestion or landfilling which raised several environmental issues. The newly developed process used a six-step method to convert scum to biodiesel, a higher value product. A combination of acid washing and acid catalyzed esterification was developed to remove soap and impurities while converting free fatty acids to methyl esters. A glycerol washing was used to facilitate the separation of biodiesel and glycerin after base catalyzed transesterification. As a result, 70% of dried and filtered scum was converted to biodiesel which is equivalent to about 134,000 gallon biodiesel per year for the Saint Paul waste water treatment plant in Minnesota. Copyright © 2015 Elsevier Ltd. All rights reserved.
Lagrada, Leizel P; Uehara, Naruo; Kawahara, Kazuo
2008-12-01
STUDY BACKGROUND AND OBJECTIVES: The Philippines is one of the 22 countries with high TB burden. DOTS was adopted not only by purely public providers (PP) but also by public-private mix (PPM) facilities. This study aims to identify the patient and facility factors that promote completion of TB treatment in DOTS facilities in an urban setting. The study also explores the difference between the PP and PPM DOTS facilities in terms of case management and treatment outcomes. [Methods] A case control study was done by interviewing 394 patients sampled from TB cohort report between 2003 and 2005 of 14 DOTS facilities in Metro Manila. Statistical analyses used include chi-square test and logistic regression analysis. Being female and aged 30-44 (OR = 7.04; 95% CI 1.12-44.35), unemployed (OR = 2.73; 95% CI 1.18-6.33), being above per capita poverty threshold (OR = 2.03; 95% CI 1.03-3.99), having experienced at least one of the signs and symptoms of TB (OR = 4.64; 95% CI 1.29-16.67), taking the medication at health facility (OR = 3.87; 95% CI 1.48-10.16) and patient's understanding of DOT (OR = 2.67; 95% CI 1.37-5.23) predict TB treatment completion. Public-private mix type of DOTS facility was also significantly associated with completing treatment (chi 2 (1) = 54.76, p = 0.000). Patient factors like middle-aged female compared to female aged more than 60, being above per capita poverty threshold, unemployment and having experienced at least one signs and symptoms of TB and facility factors like providing treatment at the facility and explaining the DOT to patient increase the likelihood of completing treatment. Thus, encouraging patients to take their medication at the facility and helping the patients understand the importance of DOT can increase TB treatment completion. The seemingly better DOTS implementation and treatment outcomes by the PPM must be evaluated further through cost effectiveness and efficiency studies.
Berzi, Lorenzo; Delogu, Massimo; Giorgetti, Alessandro; Pierini, Marco
2013-04-01
The present article analyses the current situation of End-of-Life-of-Vehicles (ELVs) management in Europe, with particular attention on Italian condition. Similarly to other European countries, metal recycling is the main activity of the whole system, but such situation is evolving due to the 2000/53/EC Directive, which sets out targets for Reuse, Recycling and Recovery of ELVs. Due to the relevance of the ELVs problem, in 2008 Italian Ministry of Environment subscribed a framework agreement with competent stakeholders as carmakers, dismantlers, shredders. The main result is an industrial plan to promote (amongst other objectives) technological progress for residual waste (Automotive Shredder Residue-ASR) treatment. According with Italian Trial 2006 analysis about ELVs, Reuse and Recycling rate is currently estimated to be about 81%. At the present time, dismantling plants constitute the first collection points for ELVs; for this reason, during 2009 an investigation has been done over a number of ten Authorized Treatment Facilities (ATFs) operating in Italy. The first step of the analysis was aimed to find out major practices and methods through observations of ATFs activities and interviews to operators. Furthermore, the depollution and dismantling treatments of about 70 different ELVs have been observed and timed in detail over a period of three months. The results included the identification of most relevant critical issues in ELVs treatment, such as distortions between scrapping activities and Directive's regulation, and the assessment of the time and of the resources needed to perform each operation. In the second step of the survey, a process simulation model has been built on the basis of such data. The model was aimed to include the real variability and all the uncertainties that are typical of dismantling activities; it is intended as a tool for process layout planning and for its management. Some control parameters have been introduced; these are able to dynamically modify process path depending on ELVs queues and priorities. The model can also be used for the economic assessments of single operations or of the whole treatment activity. Copyright © 2012 Elsevier Ltd. All rights reserved.
Technological and life cycle assessment of organics processing odour control technologies.
Bindra, Navin; Dubey, Brajesh; Dutta, Animesh
2015-09-15
As more municipalities and communities across developed world look towards implementing organic waste management programmes or upgrading existing ones, composting facilities are emerging as a popular choice. However, odour from these facilities continues to be one of the most important concerns in terms of cost & effective mitigation. This paper provides a technological and life cycle assessment of some of the different odour control technologies and treatment methods that can be implemented in organics processing facilities. The technological assessment compared biofilters, packed tower wet scrubbers, fine mist wet scrubbers, activated carbon adsorption, thermal oxidization, oxidization chemicals and masking agents. The technologies/treatment methods were evaluated and compared based on a variety of operational, usage and cost parameters. Based on the technological assessment it was found that, biofilters and packed bed wet scrubbers are the most applicable odour control technologies for use in organics processing faculties. A life cycle assessment was then done to compare the environmental impacts of the packed-bed wet scrubber system, organic (wood-chip media) bio-filter and inorganic (synthetic media) bio-filter systems. Twelve impact categories were assessed; cumulative energy demand (CED), climate change, human toxicity, photochemical oxidant formation, metal depletion, fossil depletion, terrestrial acidification, freshwater eutrophication, marine eutrophication, terrestrial eco-toxicity, freshwater eco-toxicity and marine eco-toxicity. The results showed that for all impact categories the synthetic media biofilter had the highest environmental impact, followed by the wood chip media bio-filter system. The packed-bed system had the lowest environmental impact for all categories. Copyright © 2015 Elsevier B.V. All rights reserved.
Nitrogen removal process optimization in New York City WPCPS: a case study of Wards Island WPCP.
Ramalingam, K; Fillos, J; Musabyimana, M; Deur, A; Beckmann, K
2009-01-01
The New York City Department of Environmental Protection has been engaged in a continuous process to develop a nitrogen removal program to reduce the nitrogen mass discharge from its water pollution control plants, (WPCPs), from 49,158 kg/d to 20,105 kg/d by the year 2017 as recommended by the Long Island Sound Study. As part of the process, a comprehensive research effort was undertaken involving bench, pilot and full scale studies to identify the most effective way to upgrade and optimize the existing WPCPs. Aeration tank 13 (AT-13) at the Wards Island WPCP was particularly attractive as a full-scale research facility because its aeration tank with its dedicated final settling tanks and RAS pumps could be isolated from the remaining treatment facilities. The nitrogen removal performance of AT-13, which, at the time, was operated as a "basic step feed BNR Facility", was evaluated and concurrently nitrification kinetic parameters were measured using in-situ bench scale experiments. Additional bench scale experiments provided denitrification rates using different sources of carbon and measurement of the maximum specific growth rate of nitrifying bacteria. The combined findings were then used to upgrade AT-13 to a "full" BNR facility with carbon and alkalinity addition. This paper will focus on the combined bench and full scale results that were the basis for the consequent upgrade.
Signal processing techniques were applied to high-resolution time series data obtained from conductivity loggers placed upstream and downstream of an oil and gas wastewater treatment facility along a river. Data was collected over 14-60 days. The power spectral density was us...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
TREATMENT OF ARSENIC RESIDUALS FROM DRINKING WATER REMOVAL PROCESSES
The drinking water MCL was recently lowered from 0.05 mg/L to 0.01 mg/L. One concern was that reduction in the TCLP arsenic limit in response to the drinking water MCL could be problematic with regard to disposal of solid residuals generated at arsenic removal facilities. This pr...
Evaluation of Components of Residential Treatment by Medicaid ICF-MR Surveys: A Validity Assessment.
ERIC Educational Resources Information Center
Reid, Dennis H.; And Others
1991-01-01
Four studies found serious problems with components of the federal Medicaid program's survey process for evaluating intermediate care facilities for the mentally retarded--surveys did not discriminate between certified and noncertified units, direct-care staff behavior was very reactive to the survey's presence, and service providers had divergent…
Coping with Parental Loss because of Termination of Parental Rights
ERIC Educational Resources Information Center
Schneider, Kerri M.; Phares, Vicky
2005-01-01
This article addresses the process by which children and adolescents cope with severe acute stress of parental loss from causes other than divorce or death. Participants were 60 children and adolescents from a residential treatment facility. Most had experienced neglect, physical abuse, and sexual abuse, and their parents had their parential…
Arsenic uptake processes were evaluated in a zerovalent iron reactive barrier installed at a lead smelting facility using geochemical modeling, solid-phase analysis, and X-ray absorption spectroscopy techniques. Aqueous speciation of arsenic plays a key role in directing arsenic...
Math Problems for Water Quality Control Personnel, Instructor's Manual. Second Edition.
ERIC Educational Resources Information Center
Delvecchio, Fred; Brutsch, Gloria
This document is the instructor's manual for a course in mathematics for water quality control personnel. It is designed so a program may be designed for a specific facility. The problem structures are arranged alphabetically by treatment process. Charts, graphs and/or drawings representing familiar data forms contain the necessary information to…
40 CFR 440.132 - General definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... grouting the tailings pond or wastewater holding facility. (e) “In-situ leach methods” means the processes... land on or in which grading has been completed to return the earth to desired contour and reclamation... evaporation data. (c) “Appropriate treatment of the recycle water” in subpart J, § 440.104 includes, but is...
Adesoro, Olatunde; Shumba, Constance; Kpamor, John; Achan, Jane; Kivumbi, Harriet; Dada, John; Maxwell, Kolawole; Tibenderana, James; Marasciulo, Madeline; Hamade, Prudence; Oresanya, Olusola; Nankabirwa, Joanita; Baba, Ebenezer
2016-10-12
Innovative strategies are needed to reduce malaria mortality in high burden countries like Nigeria. Given that one of the important reasons for this high malaria mortality is delay in receiving effective treatment, improved access to such treatment is critical. Intramuscular artesunate could be used at lower-level facilities given its proven efficacy, ease of use and excellent safety profile. The objective of this study was therefore to explore health workers' perspectives on the possible use of intramuscular artesunate as definitive treatment for severe malaria at lower-level facilities, especially when access to referral facilities is challenging. The study was to provide insight as a formative step into the conduct of future experimental studies to ascertain the feasibility of the use of intramuscular artesunate for definitive treatment of severe malaria in lower level facilities where access to referral care is limited. This qualitative study was done across three southern States in Nigeria (Oyo, Cross River and Enugu). Key informant interviews were conducted over a period of three months between October and December 2014 among 90 purposively selected health workers with different roles in malaria case management from primary care to policy level. A thematic content analysis was used to analyse data. Overall, most of health workers and other key informant groups thought that the use of intramuscular artesunate for definitive treatment of severe malaria at lower-level facilities was possible. They however reported human resource and infrastructure constraints as factors affecting the feasibility of intramuscular artesunate use as definitive treatment for severe malaria in lower-level facilities.. Specifically identified barriers included limited numbers of skilled health workers available to manage potential complications of severe malaria and poorly equipped facilities for supportive treatment. Intramuscular artesunate was considered easy to administer and the proximity of lower-level facilities to communities was deemed important in considering the possibility of its use at lower-level facilities. Health workers also emphasised the important role of operational research to provide additional evidence to guide the implementation of existing policy recommendations and inform future policy revisions. From the perspective of health workers, use of intramuscular artesunate for definitive treatment of severe malaria at lower-level health facilities in Nigeria is possible but dependent on availability of skilled workers, well-equipped lower-level facilities to provide supportive treatment There is need for further operational research to establish feasibility and guide the implementation of such an intervention.
Malcolm, R.L.; Wershaw, R. L.; Thurman, E.M.; Aiken, G.R.; Pinckney, D.J.; Kaakinen, J.
1981-01-01
Smectite clay minerals were found to be the principal compound on the surface of the cellulose-acetate, reverse-osmosis membranes at the Yuma Desalting Test Facility. These clay minerals were not present in the pumped ground water, but were blown into the conveyance canal from adjacent soils. Humic substances from the water and suspended sediments were associated with the clay films on the membrane, but no definitive results concerning their role in fouling were achieved. Microbial fouling is believed to be only a minor aspect of membrane fouling. Chemical and physical changes in humic substances were extensively studied at four points in the water-treatment process. Humic substances accounted for the largest component (over 25 percent) of organic constituents. Humic substances in the canal source water were similar to other aquatic humic substances present in natural waters. During the treatment process, these substances are brominated and decolorized. The effect of these halogenated humic substances on membrane fouling is unclear, but their presence in the reverse-osmosis product water and reverse-osmosis reject brine, along with volatile trihalomethanes, has led to environmental concerns. (USGS)
Projected Salt Waste Production from a Commercial Pyroprocessing Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, Michael F.
Pyroprocessing of used nuclear fuel inevitably produces salt waste from electrorefining and/or oxide reduction unit operations. Various process design characteristics can affect the actual mass of such waste produced. This paper examines both oxide and metal fuel treatment, estimates the amount of salt waste generated, and assesses potential benefit of process options to mitigate the generation of salt waste. For reference purposes, a facility is considered in which 100 MT/year of fuel is processed. Salt waste estimates range from 8 to 20 MT/year from considering numerous scenarios. It appears that some benefit may be derived from advanced processes for separatingmore » fission products from molten salt waste, but the degree of improvement is limited. Waste form production is also considered but appears to be economically unfavorable. Direct disposal of salt into a salt basin type repository is found to be the most promising with respect to minimizing the impact of waste generation on the economic feasibility and sustainability of pyroprocessing.« less
Controlling changes - lessons learned from waste management facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, B.M.; Koplow, A.S.; Stoll, F.E.
This paper discusses lessons learned about change control at the Waste Reduction Operations Complex (WROC) and Waste Experimental Reduction Facility (WERF) of the Idaho National Engineering Laboratory (INEL). WROC and WERF have developed and implemented change control and an as-built drawing process and have identified structures, systems, and components (SSCS) for configuration management. The operations have also formed an Independent Review Committee to minimize costs and resources associated with changing documents. WROC and WERF perform waste management activities at the INEL. WROC activities include storage, treatment, and disposal of hazardous and mixed waste. WERF provides volume reduction of solid low-levelmore » waste through compaction, incineration, and sizing operations. WROC and WERF`s efforts aim to improve change control processes that have worked inefficiently in the past.« less
Radioactive Waste Management and Nuclear Facility Decommissioning Progress in Iraq - 13216
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Musawi, Fouad; Shamsaldin, Emad S.; Jasim, Hadi
2013-07-01
Management of Iraq's radioactive wastes and decommissioning of Iraq's former nuclear facilities are the responsibility of Iraq's Ministry of Science and Technology (MoST). The majority of Iraq's former nuclear facilities are in the Al-Tuwaitha Nuclear Research Center located a few kilometers from the edge of Baghdad. These facilities include bombed and partially destroyed research reactors, a fuel fabrication facility and radioisotope production facilities. Within these facilities are large numbers of silos, approximately 30 process or waste storage tanks and thousands of drums of uncharacterised radioactive waste. There are also former nuclear facilities/sites that are outside of Al-Tuwaitha and these includemore » the former uranium processing and waste storage facility at Jesira, the dump site near Adaya, the former centrifuge facility at Rashdiya and the former enrichment plant at Tarmiya. In 2005, Iraq lacked the infrastructure needed to decommission its nuclear facilities and manage its radioactive wastes. The lack of infrastructure included: (1) the lack of an organization responsible for decommissioning and radioactive waste management, (2) the lack of a storage facility for radioactive wastes, (3) the lack of professionals with experience in decommissioning and modern waste management practices, (4) the lack of laws and regulations governing decommissioning or radioactive waste management, (5) ongoing security concerns, and (6) limited availability of electricity and internet. Since its creation eight years ago, the MoST has worked with the international community and developed an organizational structure, trained staff, and made great progress in managing radioactive wastes and decommissioning Iraq's former nuclear facilities. This progress has been made, despite the very difficult implementing conditions in Iraq. Within MoST, the Radioactive Waste Treatment and Management Directorate (RWTMD) is responsible for waste management and the Iraqi Decommissioning Directorate (IDD) is responsible for decommissioning activities. The IDD and the RWTMD work together on decommissioning projects. The IDD has developed plans and has completed decommissioning of the GeoPilot Facility in Baghdad and the Active Metallurgical Testing Laboratory (LAMA) in Al-Tuwaitha. Given this experience, the IDD has initiated work on more dangerous facilities. Plans are being developed to characterize, decontaminate and decommission the Tamuz II Research Reactor. The Tammuz Reactor was destroyed by an Israeli air-strike in 1981 and the Tammuz II Reactor was destroyed during the First Gulf War in 1991. In addition to being responsible for managing the decommissioning wastes, the RWTMD is responsible for more than 950 disused sealed radioactive sources, contaminated debris from the first Gulf War and (approximately 900 tons) of naturally-occurring radioactive materials wastes from oil production in Iraq. The RWTMD has trained staff, rehabilitated the Building 39 Radioactive Waste Storage building, rehabilitated portions of the French-built Radioactive Waste Treatment Station, organized and secured thousands of drums of radioactive waste organized and secured the stores of disused sealed radioactive sources. Currently, the IDD and the RWTMD are finalizing plans for the decommissioning of the Tammuz II Research Reactor. (authors)« less
Triggers of self-conscious emotions in the sexually transmitted infection testing process
2010-01-01
Background Self-conscious emotions (shame, guilt and embarrassment) are part of many individuals' experiences of seeking STI testing. These emotions can have negative impacts on individuals' interpretations of the STI testing process, their willingness to seek treatment and their willingness to inform sexual partners in light of positive STI diagnoses. Because of these impacts, researchers have called for more work to be completed on the connections between shame, guilt, embarrassment and STI testing. We examine the specific events in the STI testing process that trigger self-conscious emotions in young adults who seek STI testing; and to understand what it is about these events that triggers these emotions. Semi-structured interviews with 30 adults (21 women, 9 men) in the Republic of Ireland. Findings Seven specific triggers of self-conscious emotions were identified. These were: having unprotected sex, associated with the initial reason for seeking STI testing; talking to partners and peers about the intention to seek STI testing; the experience of accessing STI testing facilities and sitting in clinic waiting rooms; negative interactions with healthcare professionals; receiving a positive diagnosis of an STI; having to notify sexual partners in light of a positive STI diagnosis; and accessing healthcare settings for treatment for an STI. Self-conscious emotions were triggered in each case by a perceived threat to respondents' social identities. Conclusion There are multiple triggers of self-conscious emotions in the STI testing process, ranging from the initial decision to seek testing, right through to the experience of accessing treatment. The role of self-conscious emotions needs to be considered in each component of service design from health promotion approaches, through facility layout to the training of all professionals involved in the STI testing process. PMID:20716339
Gingerich, Daniel B; Mauter, Meagan S
2017-09-19
Water treatment processes present intersectoral and cross-media risk trade-offs that are not presently considered in Safe Drinking Water Act regulatory analyses. This paper develops a method for assessing the air emission implications of common municipal water treatment processes used to comply with recently promulgated and proposed regulatory standards, including concentration limits for, lead and copper, disinfection byproducts, chromium(VI), strontium, and PFOA/PFOS. Life-cycle models of electricity and chemical consumption for individual drinking water unit processes are used to estimate embedded NO x , SO 2 , PM 2.5 , and CO 2 emissions on a cubic meter basis. We estimate air emission damages from currently installed treatment processes at U.S. drinking water facilities to be on the order of $500 million USD annually. Fully complying with six promulgated and proposed rules would increase baseline air emission damages by approximately 50%, with three-quarters of these damages originating from chemical manufacturing. Despite the magnitude of these air emission damages, the net benefit of currently implemented rules remains positive. For some proposed rules, however, the promise of net benefits remains contingent on technology choice.
Region 9 NPDES Facilities 2012- Waste Water Treatment Plants
Point geospatial dataset representing locations of NPDES Waste Water Treatment Plant Facilities. NPDES (National Pollution Discharge Elimination System) is an EPA permit program that regulates direct discharges from facilities that discharge treated waste water into waters of the US. Facilities are issued NPDES permits regulating their discharge as required by the Clean Water Act. A facility may have one or more outfalls (dischargers). The location represents the facility or operating plant.
NASA Astrophysics Data System (ADS)
Rankin, Matthew J.
Anaerobic digestion is a microbiological process that converts biodegradable organic material into biogas, consisting primarily of methane and carbon dioxide. Anaerobic digestion technologies have been integrated into wastewater treatment facilities nationwide for many decades to increase the economic viability of the treatment process by converting a waste stream into two valuable products: biogas and fertilizer. Thus, anaerobic digestion offers potential economic and environmental benefits of organic waste diversion and renewable energy generation. The use of biogas has many applications, including cogeneration, direct combustion, upgrading for conversion to feed a fuel cell, and compression for injection into the natural gas grid or for vehicular use. The potential benefits of waste diversion and renewable energy generation are now being realized by major organic waste generators in New York State, in particular the food manufacturing and dairy industries, thus warranting an analysis of the energy generation potential for these waste products. Anaerobic codigestion of dairy manure and food-based feedstocks reflects a cradle-to- cradle approach to organic waste management. Given both of their abundance throughout New York State, waste-to-energy processes represent promising waste management strategies. The objective of this thesis was to evaluate the current technical and economic feasibility of anaerobically codigesting existing dairy manure and food manufacturing waste feedstocks in New York State to produce high quality biogas for renewable energy generation. The first element to determining the technical feasibility of anaerobic codigestion potential in New York State was to first understand the feedstock availability. A comprehensive survey of existing organic waste streams was conducted. The key objective was to identify the volume and composition of dairy manure and liquid-phase food manufacturing waste streams available in New York State to make codigestion of multiple feedstocks in centralized anaerobic codigestion facilities an economically attractive alternative to traditional waste disposal pathways (e.g. landfill and wastewater treatment facilities). A technical and environmental assessment of processing food manufacturing wastes and dairy manure for production of electricity via cogeneration, while dependent on biogas quantity and quality as well as the proximity of the waste generators to the centralized codigestion facility, suggests that a real possibility exists for integrating dairy operations with food manufacturing facilities, dependent on the values of the parameters indicated in this thesis. The results of the environmental analysis show that considerable electricity generation and greenhouse gas emissions reductions are possible, depending primarily on feedstock availability and proximity to the centralized anaerobic digester. The initial results are encouraging and future work is warranted for analyzing the site-specific technical and economic viability of codigesting dairy manure and food manufacturing wastes to produce high quality biogas for renewable energy generation in New York State.
Application of nuclear physics in medical physics and nuclear medicine
NASA Astrophysics Data System (ADS)
Hoehr, Cornelia
2016-09-01
Nuclear physics has a long history of influencing and advancing medical fields. At TRIUMF we use the applications of nuclear physics to diagnose several diseases via medical isotopes and treat cancer by using proton beams. The Life Science division has a long history of producing Positron Emission Tomography (PET) isotopes but we are also investigating the production of SPECT and PET isotopes with a potential shortage for clinical operation or otherwise limited access to chemists, biologists and medical researchers. New targets are being developed, aided by a simulation platform investigating the processes inside a target under proton irradiation - nuclear, thermodynamic, and chemical. Simulations also aid in the development of new beam-shaping devices for TRIUMF's Proton Therapy facility, Canada's only proton therapy facility, as well as new treatment testing systems. Both promise improved treatment delivery for cancer patients.
Hochgesang, Mindy; Zamudio-Haas, Sophia; Moran, Lissa; Nhampossa, Leopoldo; Packel, Laura; Leslie, Hannah; Richards, Janise; Shade, Starley B
2017-01-01
The rapid scale-up of HIV care and treatment in resource-limited countries requires concurrent, rapid development of health information systems to support quality service delivery. Mozambique, a country with an 11.5% prevalence of HIV, has developed nation-wide patient monitoring systems (PMS) with standardized reporting tools, utilized by all HIV treatment providers in paper or electronic form. Evaluation of the initial implementation of PMS can inform and strengthen future development as the country moves towards a harmonized, sustainable health information system. This assessment was conducted in order to 1) characterize data collection and reporting processes and PMS resources available and 2) provide evidence-based recommendations for harmonization and sustainability of PMS. This baseline assessment of PMS was conducted with eight non-governmental organizations that supported the Ministry of Health to provide 90% of HIV care and treatment in Mozambique. The study team conducted structured and semi-structured surveys at 18 health facilities located in all 11 provinces. Seventy-nine staff were interviewed. Deductive a priori analytic categories guided analysis. Health facilities have implemented paper and electronic monitoring systems with varying success. Where in use, robust electronic PMS facilitate facility-level reporting of required indicators; improve ability to identify patients lost to follow-up; and support facility and patient management. Challenges to implementation of monitoring systems include a lack of national guidelines and norms for patient level HIS, variable system implementation and functionality, and limited human and infrastructure resources to maximize system functionality and information use. This initial assessment supports the need for national guidelines to harmonize, expand, and strengthen HIV-related health information systems. Recommendations may benefit other countries with similar epidemiologic and resource-constrained environments seeking to improve PMS implementation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Social identity, social networks and recovery capital in emerging adulthood: A pilot study.
Mawson, E; Best, D; Beckwith, M; Dingle, G A; Lubman, D I
2015-11-11
It has been argued that recovery from substance dependence relies on a change in identity, with past research focused on 'personal identity'. This study assessed support for a social identity model of recovery in emerging adults through examining associations between social identity, social networks, recovery capital, and quality of life. Twenty participants aged 18-21 in residential treatment for substance misuse were recruited from four specialist youth drug treatment services - three detoxification facilities and one psychosocial rehabilitation facility in Victoria, Australia. Participants completed a detailed social network interview exploring the substance use of groups in their social networks and measures of quality of life, recovery capital, and social identity. Lower group substance use was associated with higher recovery capital, stronger identification with non-using groups, and greater importance of non-using groups in the social network. Additionally, greater identification with and importance of non-using groups were associated with better environmental quality of life, whereas greater importance conferred on using groups was associated with reduced environmental quality of life. Support was found for the role of social identity processes in reported recovery capital and quality of life. Future research in larger, longitudinal samples is required to improve understanding of social identity processes during treatment and early recovery and its relationship to recovery stability.
Financial Assurance Requirements for Hazardous Waste Treatment, Storage and Disposal Facilities
The Resource Conservation and Recovery Act (RCRA) requires all treatment, storage and disposal facilities (TSDFs) to demonstrate that they will have the financial resources to properly close the facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Maria, Francesco, E-mail: francesco.dimaria@unipg.it; Micale, Caterina; Morettini, Emanuela
2015-10-15
Highlights: • LCA analysis of two option for residual waste management. • Exploitation of mechanical physical sorting facility for extracting recyclable from RMSW. • Processing the mechanically sorted organic fraction in bioreactor landfill. • Sensitivity analysis demonstrate high influence for impact assessment of substitution ratio for recycle materials. - Abstract: Starting from an existing waste management district without thermal treatment facilities, two different management scenarios for residual waste were compared by life cycle assessment (LCA). The adoption of a bioreactor landfill for managing the mechanically sorted organic fraction instead of bio-stabilization led to reduction of global warming and fresh watermore » eutrophication by 50% and 10%, respectively. Extraction of recyclables from residual waste led to avoided emissions for particulate matter, acidification and resource depletion impact categories. Marginal energy and the amount of energy recovered from landfill gas marginally affected the LCA results. On the contrary the quality of the recyclables extracted can significantly modify the eco profile of the management schemes.« less
Pain treatment facilities: do we need quantity or quality?
de Meij, Nelleke; Köke, Albère; van der Weijden, Trudy; van Kleef, Maarten; Patijn, Jacob
2014-10-01
Chronic pain patients referred to a pain treatment facility have no guarantee that they will receive a proper diagnostic procedure or treatment. To obtain information about organizational aspects of pain treatment facilities and the content of their daily pain practice, we performed a questionnaire survey. The aim of the study was to evaluate the amount of pain treatment facilities, the content of organized specialized pain care and adherence to the criteria of the internationally accepted guidelines for pain treatment services. The University Pain Centre Maastricht in the Department of Anaesthesiology and Pain Management at Maastricht University Medical Centre developed a questionnaire survey based on the Recommendations for Pain Treatment Services of the International Association for the Study of Pain (IASP). The questionnaire was sent to the medical boards of all hospitals in the Netherlands (n=94). The response rate was 86% (n=81). Of all hospitals, 88.9% (n=72) reported the provision of organized specialized pain care, which was provided by a pain management team in 86.1% (n=62) and by an individual specialist in 13.9% (n=10). Insight was obtained from pain treatment facilities in five different domains: the organizational structure of pain management, composition of the pain team, pain team practice, patient characteristics, and research and education facilities. Although 88.9% of all hospitals stated that organized specialized pain care was provided, only a few hospitals could adhere to the criteria for pain treatment services of the IASP. The outcome of the questionnaire survey may help to define quality improvement standards for pain treatment facilities. © 2014 John Wiley & Sons, Ltd.
The role of institutions on the effectiveness of malaria treatment in the Ghanaian health sector.
Amporfu, Eugenia; Nonvignon, Justice
2015-04-19
The Ghanaian health sector has undertaken several policies to help improve the quality of care received by patients. This includes the construction of several health facilities, the increase in the training of health workers, especially nurses, and the introduction of incentive packages (such as salary increase) to motivate health workers. The important question is to what extent does the institutional arrangement between the health facilities and the government as well as between health workers and public health facility administration affect the quality of care? The objective of this study is to find the effect of institutional factors on the quality of care. The institutional factors examined were mainly the extent of decentralization between government and health facilities, as well as between health workers and facility administration, the hiring procedure, and job satisfaction. The study used primary data on former patients from sixty six health facilities in three administrative regions of Ghana: the Northern, the Ashanti and the Greater Accra regions. The quality indicator used was effectiveness of treatment as determined by the patient. Ordered logit regression was run for the indicator with patient and health facility characteristics as well as institutional factors as independent variables. The sample size was 2248. The results showed that the patient's level of formal education had a strong influence on the effectiveness of treatment. In addition, effectiveness of treatment differed according to the administrative region in which the facility was located, and according to the extent of decentralization between health facility and government. The quality of instruments used for treatment, the working conditions for health workers, and job satisfaction had no effect on the effectiveness of treatment. Decentralization, the flow of information from government to health facilities and from health facility administrators to health workers are important in ensuring effectiveness. The study recommends further decentralization between health facilities as well as between health workers and administrators. In addition, the study recommends the involvement of health facilities in malaria programs to ensure the flow of information needed for effectiveness of treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coenenberg, J.G.
1997-08-15
The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit applicationmore » guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating text. 38 39 Information provided in this Liquid Effluent Retention Facility and 40 200 Area Effluent Treatment Facility permit application documentation is 41 current as of June 1, 1997.« less
Bark-beetle infestation affects water quality in the Rocky Mountains of Colorado
NASA Astrophysics Data System (ADS)
Mikkelson, K.; Dickenson, E.; Maxwell, R. M.; McCray, J. E.; Sharp, J. O.
2012-12-01
In the previous decade, millions of acres in the Rocky Mountains of Colorado have been infested by the mountain pine beetle (MPB) leading to large-scale tree mortality. These vegetation changes can impact hydrological and biogeochemical processes, possibly altering the leaching of natural organic matter to surrounding waters and increasing the potential for harmful disinfection byproducts (DBP) during water treatments. To investigate these adverse outcomes, we have collected water quality data sets from local water treatment facilities in the Rocky Mountains of Colorado that have either been infested with MPB or remain a control. Results demonstrate significantly more total organic carbon (TOC) and DBPs in water treatment facilities receiving their source water from infested watersheds as compared to the control sites. Temporal DBP concentrations in MPB-watersheds also have increased significantly in conjunction with the bark-beetle infestation. Interestingly, only modest increases in TOC concentrations were observed in infested watersheds despite more pronounced increases in DBP concentrations. Total trihalomethanes, a heavily regulated DBP, was found to approach the regulatory limit in two out of four reporting quarters at facilities receiving their water from infested forests. These findings indicate that bark-beetle infestation alters TOC composition and loading in impacted watersheds and that this large-scale phenomenon has implications on the municipal water supply in the region.
Problem Severity Profiles of Substance Abusing Women in Therapeutic Treatment Facilities
ERIC Educational Resources Information Center
Isralowitz, Richard; Reznik, Alexander
2009-01-01
This article aims to examine specific substance use profiles among former Soviet Union (FSU) immigrant and native-born women in Israeli therapeutic treatment facilities. Individuals were sampled at drug treatment facilities and assessed using the Addiction Severity Index. ASI scores suggest differences between the two groups. Among the findings…
26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 3 2014-04-01 2014-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...
26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... Treatment of certain expenditures with respect to entertainment-type facilities. If deductions are...
26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 3 2012-04-01 2012-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...
26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 3 2013-04-01 2013-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...
26 CFR 1.274-7 - Treatment of certain expenditures with respect to entertainment-type facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 3 2011-04-01 2011-04-01 false Treatment of certain expenditures with respect to entertainment-type facilities. 1.274-7 Section 1.274-7 Internal Revenue INTERNAL REVENUE SERVICE... § 1.274-7 Treatment of certain expenditures with respect to entertainment-type facilities. If...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equal to the difference between annual precipitation falling on the treatment facility and the...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (2) In the event that the annual precipitation falling on the treatment facility and the drainage area contributing surface runoff to the treatment facility exceeds the annual evaporation, a volume of water equivalent to the difference between annual precipitation falling on the treatment facility and...
Santone, Giovanni; Bellantuono, Cesario; Rucci, Paola; Picardi, Angelo; Preti, Antonio; de Girolamo, Giovanni
2011-05-01
The present study investigated: (i) the rate of prescription of antipsychotic (AP) polypharmacy (APP) in a large, representative sample of psychiatric inpatients; and (ii) the relationship between APP prescription and the characteristics of patients and facilities. The sample included 1022 psychiatric patients scheduled to be discharged from acute inpatient facilities with drug therapies including AP. Demographic and clinical data were obtained from the treating physician or retrieved from patients' records through a standardized Patient Form. Patients were administered the 24-item Brief Psychiatric Rating Scale. Three indicators were used to describe the process of care in the facilities: a Restrictiveness score, a Standardization score, and a Treatment score. A multilevel mixed-effect logistic regression was used to predict APP using patient and facility as the variables. APP was prescribed to 333 (32.5%) patients, the most common patterns being a first-generation and a second-generation AP (n = 178, 17.6%) or of two first-generation APs (n = 80, 7.8%). Patients with a diagnosis of schizophrenia and poorer insight into illness at admission were significantly more likely to receive APP. The availability of more complex therapeutic interventions in the facility was also associated with APP. In our nationwide sample of psychiatric inpatients, APP was frequently prescribed to treat the more severe patients. However, it was also associated with process of care characteristics such as delivery of more complex therapeutic interventions, and was therefore not used only to control patient behavior. Copyright © 2010 John Wiley & Sons, Ltd.
Xu, Jianling; Yang, Jiaqi; Zhao, Nan; Sheng, Lianxi; Zhao, Yuanhui; Tang, Zhanhui
2013-07-01
Evaluation of the efficiency of aircraft liquid waste treatment has previously been conducted to prevent pollution of the environment. The current study aimed to provide a set of practical methods for efficient airport sanitary supervision. Aircraft liquid waste was collected at Longjia International Airport, Changchun from multiple flights. The efficiency of liquid waste treatment as well as the water quality of the wastewater processed via a second-stage wastewater facility were examined by measuring a number of physical, chemical, and biological indices. Our results indicated that treatment solely via resolvable sanitizing liquid was not sufficient. Although the contents of first-class pollutants all met the requirements of the standard criteria, the contents of a number of second-class pollutants did not satisfy these criteria. However, after further treatment via a second-stage wastewater facility installed at the airport, all indices reached second-grade requirements of the discharge standard. We suggest that daily inspection and quarantine indices at airports should include the suspension content, biological oxygen demands after 5 days, chemical oxygen demand total organic carbon content, amino nitrogen content, total phosphorous content, and the level of fecal coliforms.
Application of the SCADA system in wastewater treatment plants.
Dieu, B
2001-01-01
The implementation of the SCADA system has a positive impact on the operations, maintenance, process improvement and savings for the City of Houston's Wastewater Operations branch. This paper will discuss the system's evolvement, the external/internal architecture, and the human-machine-interface graphical design. Finally, it will demonstrate the system's successes in monitoring the City's sewage and sludge collection/distribution systems, wet-weather facilities and wastewater treatment plants, complying with the USEPA requirements on the discharge, and effectively reducing the operations and maintenance costs.
Ultra violet disinfection: A 3-year history
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tubesing, R.R.; Lindeke, D.R.
1998-07-01
The Stillwater Wastewater Treatment Facility is one of nine wastewater treatment facilities operated by the Metropolitan Council Environmental Services in the Minneapolis-St. Paul Metropolitan Area. The facility services the cities of Stillwater, Oak Park Heights, and Bayport. In 1993, an ultra violet disinfection facility began operation to provide the disinfection for the Facility. This presentation discusses the reasons for using ultra violet disinfection in lieu of chlorination/dechlorination facilities, the operating performance, and operating cost factors.
Gruchlik, Yolanta; Fouché, Lise; Joll, Cynthia A; Heitz, Anna
2017-12-01
Applicability of alum addition to wastewater sludge and biosolids produced from different treatment processes was evaluated as a means of odor reduction. Four water resource recovery facilities (WRRFs) were chosen for this study: two used mesophilic anaerobic digestion and two used oxidation ditch processes. The experiments were conducted on a laboratory scale and in all cases the alum was added prior to dewatering. This is the first report of the application of alum for odor reduction in oxidation ditch processes. Alum addition was effective in reducing odors in anaerobically digested biosolids. Addition of 4% alum to anaerobically digested liquid biosolids prior to dewatering resulted in a 60% reduction in the peak odor concentration in the laboratory dewatered cake, relative to the control sample. Alum addition did not reduce odors in dewatered sludge from oxidation ditch processes.
Nyblade, Laura; Jain, Aparna; Benkirane, Manal; Li, Li; Lohiniva, Anna-Leena; McLean, Roger; Turan, Janet M; Varas-Díaz, Nelson; Cintrón-Bou, Francheska; Guan, Jihui; Kwena, Zachary; Thomas, Wendell
2013-11-13
Within healthcare settings, HIV-related stigma is a recognized barrier to access of HIV prevention and treatment services and yet, few efforts have been made to scale-up stigma reduction programs in service delivery. This is in part due to the lack of a brief, simple, standardized tool for measuring stigma among all levels of health facility staff that works across diverse HIV prevalence, language and healthcare settings. In response, an international consortium led by the Health Policy Project, has developed and field tested a stigma measurement tool for use with health facility staff. Experts participated in a content-development workshop to review an item pool of existing measures, identify gaps and prioritize questions. The resulting questionnaire was field tested in six diverse sites (China, Dominica, Egypt, Kenya, Puerto Rico and St. Christopher & Nevis). Respondents included clinical and non-clinical staff. Questionnaires were self- or interviewer-administered. Analysis of item performance across sites examined both psychometric properties and contextual issues. The key outcome of the process was a substantially reduced questionnaire. Eighteen core questions measure three programmatically actionable drivers of stigma within health facilities (worry about HIV transmission, attitudes towards people living with HIV (PLHIV), and health facility environment, including policies), and enacted stigma. The questionnaire also includes one short scale for attitudes towards PLHIV (5-item scale, α=0.78). Stigma-reduction programmes in healthcare facilities are urgently needed to improve the quality of care provided, uphold the human right to healthcare, increase access to health services, and maximize investments in HIV prevention and treatment. This brief, standardized tool will facilitate inclusion of stigma measurement in research studies and in routine facility data collection, allowing for the monitoring of stigma within healthcare facilities and evaluation of stigma-reduction programmes. There is potential for wide use of the tool either as a stand-alone survey or integrated within other studies of health facility staff.
Low-Activity Waste Pretreatment System Additional Engineering-Scale Integrated Test Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Landon, Matt R.; Wilson, Robert A.
Washington River Protections Solutions, LLC’s (WRPS) Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low-activity waste (ILAW) by feeding LAW directly from Tank Farms to the Waste Treatment and Immobilization Plant (WTP) LAW Facility, bypassing the WTP Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria (WAC). Full-scale and engineering-scale testing of critical technology elements, as part of the technology maturation process, are components of the overall LAWPS Project. WRPS awarded themore » engineering-scale integrated testing scope to AECOM via WRPS Subcontract 58349. This report is deliverable MSR-008 of the subcontract.« less
Variation in fistula use across dialysis facilities: is it explained by case-mix?
Tangri, Navdeep; Moorthi, Ranjani; Tighiouhart, Hocine; Meyer, Klemens B; Miskulin, Dana C
2010-02-01
Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients. Dialysis facilities that fail to meet Centers for Medicare & Medicaid Services goals cite patient case-mix as a reason for low AVF prevalence. This study aimed to determine the magnitude of the variability in AVF usage across dialysis facilities and the extent to which patient case-mix explains it. The vascular access used in 10,112 patients dialyzed at 173 Dialysis Clinic Inc. facilities from October 1 to December 31, 2004, was evaluated. The access in use was considered to be an AVF if it was used for >70% of hemodialysis treatments. Mixed-effects models with a random intercept for dialysis facilities evaluated the effect of facilities on AVF usage. Sequentially adjusted multivariate models measured the extent to which patient factors (case-mix) explain variation across facilities in AVF rates. 3787 patients (38%) were dialyzed using AVFs. There was a significant facility effect: 7.6% of variation in AVF use was attributable to facility. This was reduced to 7.1% after case-mix adjustment. There were no identified specific facility-level factors that explained the interfacility variation. AVF usage varies across dialysis facilities, and patient case-mix did not reduce this variation. In this study, 92% of the total variation in AVF usage was due to patient factors, but most were not measurable. A combination of patient factors and process indicators should be considered in adjudicating facility performance for this quality indicator.
ERIC Educational Resources Information Center
Gearheart, Robert A.; And Others
This document is one in a series which outlines performance objectives and instructional modules for a course of study which explains the relationships and functions of the process units in a wastewater treatment plant. The modules are arranged in an order appropriate for teaching students with no experience. The modules can also be rearranged and…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, Eric M.; Mattigod, Shas V.; Westsik, Joseph H.
2010-01-30
Pacific Northwest National Laboratory has initiated a waste form testing program to support the long-term durability evaluation of a waste form for secondary wastes generated from the treatment and immobilization of Hanford radioactive tank wastes. The purpose of the work discussed in this report is to identify candidate stabilization technologies and getters that have the potential to successfully treat the secondary waste stream liquid effluent, mainly from off-gas scrubbers and spent solids, produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Down-selection to the most promising stabilization processes/waste forms is needed to support the design of a solidificationmore » treatment unit (STU) to be added to the Effluent Treatment Facility (ETF). To support key decision processes, an initial screening of the secondary liquid waste forms must be completed by February 2010.« less
NASA Astrophysics Data System (ADS)
Yver Kwok, C. E.; Müller, D.; Caldow, C.; Lebègue, B.; Mønster, J. G.; Rella, C. W.; Scheutz, C.; Schmidt, M.; Ramonet, M.; Warneke, T.; Broquet, G.; Ciais, P.
2015-07-01
This study presents two methods for estimating methane emissions from a waste water treatment plant (WWTP) along with results from a measurement campaign at a WWTP in Valence, France. These methods, chamber measurements and tracer release, rely on Fourier transform infrared spectroscopy and cavity ring-down spectroscopy instruments. We show that the tracer release method is suitable for quantifying facility- and some process-scale emissions, while the chamber measurements provide insight into individual process emissions. Uncertainties for the two methods are described and discussed. Applying the methods to CH4 emissions of the WWTP, we confirm that the open basins are not a major source of CH4 on the WWTP (about 10 % of the total emissions), but that the pretreatment and sludge treatment are the main emitters. Overall, the waste water treatment plant is representative of an average French WWTP.
RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW TREATMENT
Available technologies were evaluated to demonstrate the technical feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilities...
Kaplan, Ella; Sela, Noa; Doron-Faigenboim, Adi; Navon-Venezia, Shiri; Jurkevitch, Edouard; Cytryn, Eddie
2015-01-01
Municipal wastewater treatment facilities are considered to be “hotspots” for antibiotic resistance, since they conjoin high densities of environmental and fecal bacteria with selective pressure in the form of sub-therapeutic concentrations of antibiotics. Discharged effluents and biosolids from these facilities can disseminate antibiotic resistant genes to terrestrial and aquatic environments, potentially contributing to the increasing global trend in antibiotic resistance. This phenomenon is especially pertinent when resistance genes are associated with mobile genetic elements such as conjugative plasmids, which can be transferred between bacterial phyla. Fluoroquinolones are among the most abundant antibiotic compounds detected in wastewater treatment facilities, especially in biosolids, where due to their hydrophobic properties they accumulate to concentrations that may exceed 40 mg/L. Although fluoroquinolone resistance is traditionally associated with mutations in the gyrA/topoisomerase IV genes, there is increasing evidence of plasmid-mediated quinolone resistance, which is primarily encoded on qnr genes. In this study, we sequenced seven qnr-harboring plasmids from a diverse collection of Klebsiella strains, isolated from dewatered biosolids from a large wastewater treatment facility in Israel. One of the plasmids, termed pKPSH-11XL was a large (185.4 kbp), multi-drug resistance, IncF-type plasmid that harbored qnrB and 10 additional antibiotic resistance genes that conferred resistance to five different antibiotic families. It was highly similar to the pKPN3-like plasmid family that has been detected in multidrug resistant clinical Klebsiella isolates. In contrast, the six additional plasmids were much smaller (7–9 Kbp) and harbored a qnrS -type gene. These plasmids were highly similar to each other and closely resembled pGNB2, a plasmid isolated from a German wastewater treatment facility. Comparative genome analyses of pKPSH-11XL and other pKPN3-like plasmids concomitant to phylogenetic analysis of housekeeping genes from host Klebsiella strains, revealed that these plasmids are limited to a predominantly human-associated sub-clade of Klebsiella, suggesting that their host range is very narrow. Conversely, the pGNB2-like plasmids had a much broader host range and appeared to be associated with Klebsiella residing in natural environments. This study suggests that: (A) qnrB-harboring multidrug-resistant pKPN3-like plasmids can endure the rigorous wastewater treatment process and may therefore be disseminated to downstream environments; and (B) that small qnrS-harboring pGNB2-like plasmids are ubiquitous in wastewater treatment facilities and are most likely environmental in origin. PMID:26696974
Kaplan, Ella; Sela, Noa; Doron-Faigenboim, Adi; Navon-Venezia, Shiri; Jurkevitch, Edouard; Cytryn, Eddie
2015-01-01
Municipal wastewater treatment facilities are considered to be "hotspots" for antibiotic resistance, since they conjoin high densities of environmental and fecal bacteria with selective pressure in the form of sub-therapeutic concentrations of antibiotics. Discharged effluents and biosolids from these facilities can disseminate antibiotic resistant genes to terrestrial and aquatic environments, potentially contributing to the increasing global trend in antibiotic resistance. This phenomenon is especially pertinent when resistance genes are associated with mobile genetic elements such as conjugative plasmids, which can be transferred between bacterial phyla. Fluoroquinolones are among the most abundant antibiotic compounds detected in wastewater treatment facilities, especially in biosolids, where due to their hydrophobic properties they accumulate to concentrations that may exceed 40 mg/L. Although fluoroquinolone resistance is traditionally associated with mutations in the gyrA/topoisomerase IV genes, there is increasing evidence of plasmid-mediated quinolone resistance, which is primarily encoded on qnr genes. In this study, we sequenced seven qnr-harboring plasmids from a diverse collection of Klebsiella strains, isolated from dewatered biosolids from a large wastewater treatment facility in Israel. One of the plasmids, termed pKPSH-11XL was a large (185.4 kbp), multi-drug resistance, IncF-type plasmid that harbored qnrB and 10 additional antibiotic resistance genes that conferred resistance to five different antibiotic families. It was highly similar to the pKPN3-like plasmid family that has been detected in multidrug resistant clinical Klebsiella isolates. In contrast, the six additional plasmids were much smaller (7-9 Kbp) and harbored a qnrS -type gene. These plasmids were highly similar to each other and closely resembled pGNB2, a plasmid isolated from a German wastewater treatment facility. Comparative genome analyses of pKPSH-11XL and other pKPN3-like plasmids concomitant to phylogenetic analysis of housekeeping genes from host Klebsiella strains, revealed that these plasmids are limited to a predominantly human-associated sub-clade of Klebsiella, suggesting that their host range is very narrow. Conversely, the pGNB2-like plasmids had a much broader host range and appeared to be associated with Klebsiella residing in natural environments. This study suggests that: (A) qnrB-harboring multidrug-resistant pKPN3-like plasmids can endure the rigorous wastewater treatment process and may therefore be disseminated to downstream environments; and (B) that small qnrS-harboring pGNB2-like plasmids are ubiquitous in wastewater treatment facilities and are most likely environmental in origin.
Camargo, Anderson Carlos; Woodward, Joshua John; Call, Douglas Ruben; Nero, Luís Augusto
2017-11-01
Listeria monocytogenes is a foodborne pathogen that contaminates food-processing environments and persists within biofilms on equipment, utensils, floors, and drains, ultimately reaching final products by cross-contamination. This pathogen grows even under high salt conditions or refrigeration temperatures, remaining viable in various food products until the end of their shelf life. While the estimated incidence of listeriosis is lower than other enteric illnesses, infections caused by L. monocytogenes are more likely to lead to hospitalizations and fatalities. Despite the description of L. monocytogenes occurrence in Brazilian food-processing facilities and foods, there is a lack of consistent data regarding listeriosis cases and outbreaks directly associated with food consumption. Listeriosis requires rapid treatment with antibiotics and most drugs suitable for Gram-positive bacteria are effective against L. monocytogenes. Only a minority of clinical antibiotic-resistant L. monocytogenes strains have been described so far; whereas many strains recovered from food-processing facilities and foods exhibited resistance to antimicrobials not suitable against listeriosis. L. monocytogenes control in food industries is a challenge, demanding proper cleaning and application of sanitization procedures to eliminate this foodborne pathogen from the food-processing environment and ensure food safety. This review focuses on presenting the L. monocytogenes distribution in food-processing environment, food contamination, and control in the food industry, as well as the consequences of listeriosis to human health, providing a comparison of the current Brazilian situation with the international scenario.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nester, Dean; Crocker, Ben; Smart, Bill
2012-07-01
As part of the Plateau Remediation Project at US Department of Energy's Hanford, Washington site, CH2M Hill Plateau Remediation Company (CHPRC) contracted with IMPACT Services, LLC to receive and deactivate approximately 28 cubic meters of sodium metal contaminated debris from two sodium-cooled research reactors (Enrico Fermi Unit 1 and the Fast Flux Test Facility) which had been stored at Hanford for over 25 years. CHPRC found an off-site team composed of IMPACT Services and Commodore Advanced Sciences, Inc., with the facilities and technological capabilities to safely and effectively perform deactivation of this sodium metal contaminated debris. IMPACT Services provided themore » licensed fixed facility and the logistical support required to receive, store, and manage the waste materials before treatment, and the characterization, manifesting, and return shipping of the cleaned material after treatment. They also provided a recycle outlet for the liquid sodium hydroxide byproduct resulting from removal of the sodium from reactor parts. Commodore Advanced Sciences, Inc. mobilized their patented AMANDA unit to the IMPACT Services site and operated the unit to perform the sodium removal process. Approximately 816 Kg of metallic sodium were removed and converted to sodium hydroxide, and the project was accomplished in 107 days, from receipt of the first shipment at the IMPACT Services facility to the last outgoing shipment of deactivated scrap metal. There were no safety incidents of any kind during the performance of this project. The AMANDA process has been demonstrated in this project to be both safe and effective for deactivation of sodium and NaK. It has also been used in other venues to treat other highly reactive alkali metals, such as lithium (Li), potassium (K), NaK and Cesium (Cs). (authors)« less
Frenzel, S.A.
1988-01-01
Physical, chemical, and biological characteristics of the Boise River were examined from October 1987 to March 1988 to determine whether trace elements in effluents from two Boise wastewater treatment facilities were detrimental to aquatic communities. Cadmium, chromium, hexavalent chromium, cyanide, lead, nickel, and silver concentrations in the Boise River were less than or near analytical detection levels and were less than chronic toxicity criteria when detectable. Arsenic, copper, and zinc were detected in concentrations less than chronic toxicity criteria. Concentrations of trace elements in bottom material generally were small and could not be attributed to effluents from wastewater treatment facilities. From October to December 1987, mean density of benthic invertebrates colonizing artificial substrates was from 6,100 individuals/substrate downstream from the West Boise wastewater treatment facility to 14,000 individuals per substrate downstream from the Lander Street wastewater treatment facility. From January to March 1988 , mean density of benthic invertebrates colonizing artificial substrates was from 7,100 individuals per substrate downstream from the West Boise facility to 10,000 individuals per substrate near Star. Insect communities upstream and downstream from the wastewater treatment facilities were strongly associated, and coeffients of community loss indicated that effluents had benign enriching effects. Distribution of mayflies indicates that trace-element concentrations in effluents did not adversely affect intolerant organisms in the Boise River. Condition factor of whitefish was significantly increased downstream from the Lander Street wastewater treatment facility and was significantly decreased downstream from the West Boise wastewater treatment facility.
Gassem, Afnan Ben; Foxton, Richard; Bister, Dirk; Newton, Tim
2016-12-01
To devise and assess the psychometric properties of a measure that investigates hypodontia patients' expectations of the process and outcome of combined orthodontic/restorative treatment. Specialised secondary care facility for individuals with hypodontia. Mixed research design with three phases: (a) Thematic analysis of data from individual interviews with 25 hypodontia patients/16 parents to generate the questionnaire items. (b) Questionnaire design, assessment of readability and face/content validity with 10 patients. (c) Survey of 32 new hypodontia patients to determine the internal consistency of the measure. Three main themes related to the treatment process emerged from the qualitative data: 'hypodontia clinic', 'orthodontic treatment' and 'restorative treatment'. Three main themes were also revealed relating to treatment outcome: 'changes in appearance', 'psychosocial changes' and 'functional changes'. A 28 item questionnaire was constructed using a mix of visual analogue scale (VAS) and categorical response format. The Flesch reading ease score of the measure was 78, equivalent to a reading age of 9-10 years. Face and content validity were good. The overall Cronbach's alpha was 0.80 while for the treatment process and treatment outcome subscales it was 0.71 and 0.88 respectively. A patient-based measure of the process and outcome of combined orthodontic/restorative treatment for hypodontia patients has been developed which has good face and construct validity and satisfactory internal consistency. Patient expectations of treatment are important in determining not only their satisfaction with treatment outcomes but also their engagement with the clinical process. This questionnaire is a first step in operationalising the expectations of hypodontia patients through assessment tools that can then determine whether pre-treatment counselling is required and aid the consent and treatment planning process, thus improving the quality of treatment provided by approximating the expectations the patients hold to their actual experience. Copyright © 2016 Elsevier Ltd. All rights reserved.
Disinfection Pilot Trial for Little Miami WWTP | Science ...
There is a serious interest growing nationally towards the use of PAA at various stages of public waste water treatment facilities; one of such use is secondary waste water treatment. MSDGC is currently interested in improving efficiency and economic aspects of waste water treatment. MSDGC requested for ORD’s support to evaluate alternative cost-effective disinfectants. This report herein is based on the data generated from the field pilot test conducted at the Little Miami Wastewater Treatment Plant. Chlorine assisted disinfection of wastewaters created the concern regarding the formation of high levels of toxic halogenated disinfection byproducts (DBPs) detrimental to aquatic life and public health. Peracetic acid is emerging as a green alternative to chlorine and claimed to have economic and social benefits. In addition, it is a relatively simple retrofit to the existing chlorine treated wastewater treatment facilities. PAA is appealed to possess a much lower aquatic toxicity profile than chlorine and decays rapidly in the environment, even if overdosed. As a result, PAA generally does not need a quenching step, such as dechlorination, reducing process complexity, sodium pollution and cost. PAA treatment does not result in the formation of chlorinated disinfection by-products such as trihalomethanes (THMs), haloacetic acids and other byproducts such as cyanide and n-Nitrosodimethylamine (NDMA).
Microbial Community Profiles in Wastewaters from Onsite Wastewater Treatment Systems Technology
Jałowiecki, Łukasz; Chojniak, Joanna Małgorzata; Dorgeloh, Elmar; Hegedusova, Berta; Ejhed, Helene; Magnér, Jörgen; Płaza, Grażyna Anna
2016-01-01
The aim of the study was to determine the potential of community-level physiological profiles (CLPPs) methodology as an assay for characterization of the metabolic diversity of wastewater samples and to link the metabolic diversity patterns to efficiency of select onsite biological wastewater facilities. Metabolic fingerprints obtained from the selected samples were used to understand functional diversity implied by the carbon substrate shifts. Three different biological facilities of onsite wastewater treatment were evaluated: fixed bed reactor (technology A), trickling filter/biofilter system (technology B), and aerated filter system (the fluidized bed reactor, technology C). High similarities of the microbial community functional structures were found among the samples from the three onsite wastewater treatment plants (WWTPs), as shown by the diversity indices. Principal components analysis (PCA) showed that the diversity and CLPPs of microbial communities depended on the working efficiency of the wastewater treatment technologies. This study provided an overall picture of microbial community functional structures of investigated samples in WWTPs and discerned the linkages between microbial communities and technologies of onsite WWTPs used. The results obtained confirmed that metabolic profiles could be used to monitor treatment processes as valuable biological indicators of onsite wastewater treatment technologies efficiency. This is the first step toward understanding relations of technology types with microbial community patterns in raw and treated wastewaters. PMID:26807728
Climate Adaptation Capacity for Conventional Drinking Water Treatment Facilities
NASA Astrophysics Data System (ADS)
Levine, A.; Goodrich, J.; Yang, J.
2013-12-01
Water supplies are vulnerable to a host of climate- and weather-related stressors such as droughts, intense storms/flooding, snowpack depletion, sea level changes, and consequences from fires, landslides, and excessive heat or cold. Surface water resources (lakes, reservoirs, rivers, and streams) are especially susceptible to weather-induced changes in water availability and quality. The risks to groundwater systems may also be significant. Typically, water treatment facilities are designed with an underlying assumption that water quality from a given source is relatively predictable based on historical data. However, increasing evidence of the lack of stationarity is raising questions about the validity of traditional design assumptions, particularly since the service life of many facilities can exceed fifty years. Given that there are over 150,000 public water systems in the US that deliver drinking water to over 300 million people every day, it is important to evaluate the capacity for adapting to the impacts of a changing climate. Climate and weather can induce or amplify changes in physical, chemical, and biological water quality, reaction rates, the extent of water-sediment-air interactions, and also impact the performance of treatment technologies. The specific impacts depend on the watershed characteristics and local hydrological and land-use factors. Water quality responses can be transient, such as erosion-induced increases in sediment and runoff. Longer-term impacts include changes in the frequency and intensity of algal blooms, gradual changes in the nature and concentration of dissolved organic matter, dissolved solids, and modulation of the microbiological community structure, sources and survival of pathogens. In addition, waterborne contaminants associated with municipal, industrial, and agricultural activities can also impact water quality. This presentation evaluates relationships between climate and weather induced water quality variability and the capacity of treatment facilities and supporting water infrastructure to deliver safe drinking water consistently and reliably. Simulation models of water treatment facilities are used to evaluate the outcome of specific source water quality scenarios on treatment system performance and reliability. Modeling results are used to evaluate the process and operational capacity to respond to transient water quality changes and adapt to longer-term variability in water quality and availability. In some cases, changes in temperature and mineral content serve to improve the overall treatment performance. In addition, the integration of microbially enhanced treatment systems such as biological filtration can provide additional capacity. Conversely, changes in the nutrient and temperature dynamics can trigger algal and cyanobacterial blooms that can impair performance. Research needs are identified and the importance of developing more integrated modeling systems is highlighted.
ERIC Educational Resources Information Center
Carnegie, John W.
The rise time test (along with the settleometer procedure) is used to monitor sludge behavior in the secondary clarifier of an activated sludge system. The test monitors the effect of the nitrification/denitrification process and aids the operator in determining optimum clarifier sludge detention time and, to some extent, optimum degree of…
ERIC Educational Resources Information Center
Wooley, John F.
In the operation of vacuum filters and belt filters, it is desirable to evaluate the performance of different types of filter media and conditioning processes. The filter leaf test, which is used to evaluate these items, is described. Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1…
Autoclave Meltout of Cast Explosives
1996-08-22
various tanks , kettles , and pelletizing equipment a usable product was recovered. This process creates large amounts of pink water requiring...vacuum treatment melt kettles , flaker belts, and improved material handling equipment in an integrated system. During the 1976/1977 period, AED...McAlester Army Ammo Plant , Oklahoma, to discuss proposed workload and inspect available facilities and equipment . Pilot model production and testing
A review of double-diffusion wood preservation suitable for Alaska.
K. Josephine Pavia
2006-01-01
Currently, all treated lumber used in Alaska is imported from the 48 contiguous states and Canada because there are no wood-treating facilities in Alaska. This report explores conventional and alternative wood-treating methods and reviews previous studies and laboratory tests on treated wood. In investigating wood treatment as a possible processing option for Alaska...
Code of Federal Regulations, 2011 CFR
2011-07-01
...; plastics and resins manufacturing; pulp and paper industry; rubber and miscellaneous plastic products... wastewater treatment plant, water supply treatment plant, or air pollution control facility exclusive of the... a wastewater treatment plant, water supply treatment plant, or air pollution control facility and...
Pohlscheidt, Michael; Charaniya, Salim; Kulenovic, Fikret; Corrales, Mahalia; Shiratori, Masaru; Bourret, Justin; Meier, Steven; Fallon, Eric; Kiss, Robert
2014-04-01
The production of therapeutic proteins by mammalian cell culture is complex and sets high requirements for process, facility, and equipment design, as well as rigorous regulatory and quality standards. One particular point of concern and significant risk to supply chain is the susceptibility to contamination such as bacteria, fungi, mycoplasma, and viruses. Several technologies have been developed to create barriers for these agents to enter the process, e.g. filtration, UV inactivation, and temperature inactivation. However, if not implemented during development of the manufacturing process, these types of process changes can have significant impact on process performance if not managed appropriately. This article describes the implementation of the high-temperature short-time (HTST) treatment of cell culture media as an additional safety barrier against adventitious agents during the transfer of a large-scale commercial cell culture manufacturing process. The necessary steps and experiments, as well as subsequent results during qualification runs and routine manufacturing, are shown.
Greenhouse gas emissions from alternative water supply processes in southern California, USA
NASA Astrophysics Data System (ADS)
Schneider, A.; Townsend-Small, A.
2012-12-01
Burgeoning population centers and declining hydrological resources have encouraged the development of alternative water treatment systems, including desalination and wastewater recycling. These processes currently provide potable water for millions of people and assist in satisfying agricultural and landscaping irrigation demands. There are a variety of alternative water production methods in place, and while they help to reduce the demands placed on aquifers, during their operation they are also significant sources of greenhouse gases. The environmental advantages of these alternative water production methods need to be carefully weighed against their energy footprints and greenhouse gas emissions profiles. This study measured the greenhouse gas emissions of a wastewater treatment and recycling facility in Orange County, California to get a more complete picture of the carbon footprint of the plant. We measured atmospheric emissions of CO2, CH4, and N2O throughout the water recycling process and at various times of the day and week. This allowed us to assemble a thorough, cross-sectional profile of greenhouse gas emissions from the facility. We then compared the measured emissions of the treatment plant to the modeled emissions of desalination plants in order to assess the relative carbon footprints of the two water production methods. Other water supply alternatives, including regional water importation, were also included in the comparison in order to provide a more complete understanding of the potential greenhouse gas emissions. Finally, we assessed the significance of wastewater treatment as an urban greenhouse gas source when compared to other known emissions in the region. This research offers a valuable tool for sustainable urban and regional development by providing planners with a quantified comparison of the carbon footprints of several water production options.
Venigalla, Sriram; Nead, Kevin T; Sebro, Ronnie; Guttmann, David M; Sharma, Sonam; Simone, Charles B; Levin, William P; Wilson, Robert J; Weber, Kristy L; Shabason, Jacob E
2018-03-15
Soft tissue sarcomas (STS) are rare malignancies that require complex multidisciplinary management. Therefore, facilities with high sarcoma case volume may demonstrate superior outcomes. We hypothesized that STS treatment at high-volume (HV) facilities would be associated with improved overall survival (OS). Patients aged ≥18 years with nonmetastatic STS treated with surgery and radiation therapy at a single facility from 2004 through 2013 were identified from the National Cancer Database. Facilities were dichotomized into HV and low-volume (LV) cohorts based on total case volume over the study period. OS was assessed using multivariable Cox regression with propensity score-matching. Patterns of care were assessed using multivariable logistic regression analysis. Of 9025 total patients, 1578 (17%) and 7447 (83%) were treated at HV and LV facilities, respectively. On multivariable analysis, high educational attainment, larger tumor size, higher grade, and negative surgical margins were statistically significantly associated with treatment at HV facilities; conversely, black race and non-metropolitan residence were negative predictors of treatment at HV facilities. On propensity score-matched multivariable analysis, treatment at HV facilities versus LV facilities was associated with improved OS (hazard ratio, 0.87, 95% confidence interval, 0.80-0.95; P = .001). Older age, lack of insurance, greater comorbidity, larger tumor size, higher tumor grade, and positive surgical margins were associated with statistically significantly worse OS. In this observational cohort study using the National Cancer Database, receipt of surgery and radiation therapy at HV facilities was associated with improved OS in patients with STS. Potential sociodemographic disparities limit access to care at HV facilities for certain populations. Our findings highlight the importance of receipt of care at HV facilities for patients with STS and warrant further study into improving access to care at HV facilities. Copyright © 2017 Elsevier Inc. All rights reserved.
Safeguards Approaches for Black Box Processes or Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diaz-Marcano, Helly; Gitau, Ernest TN; Hockert, John
2013-09-25
The objective of this study is to determine whether a safeguards approach can be developed for “black box” processes or facilities. These are facilities where a State or operator may limit IAEA access to specific processes or portions of a facility; in other cases, the IAEA may be prohibited access to the entire facility. The determination of whether a black box process or facility is safeguardable is dependent upon the details of the process type, design, and layout; the specific limitations on inspector access; and the restrictions placed upon the design information that can be provided to the IAEA. Thismore » analysis identified the necessary conditions for safeguardability of black box processes and facilities.« less
Successful experience utilizing dexrazoxane treatment for an anthracycline extravasation.
Tyson, Abby Mercer; Gay, Wendy E
2010-05-01
To describe a successful case of dexrazoxane treatment after an extravasation of doxorubicin and share a creative solution for formulary cost management. A 42-year-old female diagnosed with breast cancer was receiving doxorubicin as adjuvant treatment. The patient recently underwent a right mastectomy for a 3-centimeter grade 3 invasive ductal carcinoma. Three of 20 lymph nodes were positive, and the patient was stage 2B at presentation, with an estrogen receptor/progesterone receptor-positive and HER-2/neu-negative tumor. At an outside hospital, the patient was receiving doxorubicin through an infusion port when extravasation was noted after approximately 15 mL had been infused. She was transferred to Riverside Methodist Hospital and dexrazoxane treatment was initiated within 6 hours after extravasation. She received a full 3-day course of dexrazoxane treatment without complication and was discharged home. Significant delays in chemotherapy administration were avoided, and the patient successfully completed her planned chemotherapy course. Dexrazoxane has the potential to minimize tissue damage and treatment delays after an anthracycline extravasation. Although dexrazoxane is commercially marketed for 2 separate treatment indications, Totect is the Food and Drug Administration-approved product for anthracycline extravasations. Facilities administering anthracyclines should proactively resolve how to obtain, process, prepare, and administer this antidote to a patient within 6 hours of an extravasation event. Developing a preprinted chemotherapy extravasation order may facilitate the incorporation of the most recent Oncology Nursing Society guidelines to utilize dexrazoxane for an anthracycline extravasation. Cost sharing with other institutions may offer a creative solution to lessen the financial impact of stocking dexrazoxane therapy. Ensuring expedient treatment and accessibility to dexrazoxane therapy after an anthracycline extravasation is critical to the success of the treatment. All facilities utilizing anthracycline chemotherapy should purchase dexrazoxane or secure agreements with other facilities to guarantee the administration of this medication should extravasation occur.
Tagar, Elya; Sundaram, Maaya; Condliffe, Kate; Matatiyo, Blackson; Chimbwandira, Frank; Chilima, Ben; Mwanamanga, Robert; Moyo, Crispin; Chitah, Bona Mukosha; Nyemazi, Jean Pierre; Assefa, Yibeltal; Pillay, Yogan; Mayer, Sam; Shear, Lauren; Dain, Mary; Hurley, Raphael; Kumar, Ritu; McCarthy, Thomas; Batra, Parul; Gwinnell, Dan; Diamond, Samantha; Over, Mead
2014-01-01
Background Today's uncertain HIV funding landscape threatens to slow progress towards treatment goals. Understanding the costs of antiretroviral therapy (ART) will be essential for governments to make informed policy decisions about the pace of scale-up under the 2013 WHO HIV Treatment Guidelines, which increase the number of people eligible for treatment from 17.6 million to 28.6 million. The study presented here is one of the largest of its kind and the first to describe the facility-level cost of ART in a random sample of facilities in Ethiopia, Malawi, Rwanda, South Africa and Zambia. Methods & Findings In 2010–2011, comprehensive data on one year of facility-level ART costs and patient outcomes were collected from 161 facilities, selected using stratified random sampling. Overall, facility-level ART costs were significantly lower than expected in four of the five countries, with a simple average of $208 per patient-year (ppy) across Ethiopia, Malawi, Rwanda and Zambia. Costs were higher in South Africa, at $682 ppy. This included medications, laboratory services, direct and indirect personnel, patient support, equipment and administrative services. Facilities demonstrated the ability to retain patients alive and on treatment at these costs, although outcomes for established patients (2–8% annual loss to follow-up or death) were better than outcomes for new patients in their first year of ART (77–95% alive and on treatment). Conclusions This study illustrated that the facility-level costs of ART are lower than previously understood in these five countries. While limitations must be considered, and costs will vary across countries, this suggests that expanded treatment coverage may be affordable. Further research is needed to understand investment costs of treatment scale-up, non-facility costs and opportunities for more efficient resource allocation. PMID:25389777
Plant-wide (BSM2) evaluation of reject water treatment with a SHARON-Anammox process.
Volcke, E I P; Gernaey, K V; Vrecko, D; Jeppsson, U; van Loosdrecht, M C M; Vanrolleghem, P A
2006-01-01
In wastewater treatment plants (WWTPs) equipped with sludge digestion and dewatering systems, the reject water originating from these facilities contributes significantly to the nitrogen load of the activated sludge tanks, to which it is typically recycled. In this paper, the impact of reject water streams on the performance of a WWTP is assessed in a simulation study, using the Benchmark Simulation Model no. 2 (BSM2), that includes the processes describing sludge treatment and in this way allows for plant-wide evaluation. Comparison of performance of a WWTP without reject water with a WWTP where reject water is recycled to the primary clarifier, i.e. the BSM2 plant, shows that the ammonium load of the influent to the primary clarifier is 28% higher in the case of reject water recycling. This results in violation of the effluent total nitrogen limit. In order to relieve the main wastewater treatment plant, reject water treatment with a combined SHARON-Anammox process seems a promising option. The simulation results indicate that significant improvements of the effluent quality of the main wastewater treatment plant can be realized. An economic evaluation of the different scenarios is performed using an Operating Cost Index (OCI).
7 CFR 305.8 - Heat treatment requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 5 2011-01-01 2011-01-01 false Heat treatment requirements. 305.8 Section 305.8... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS § 305.8 Heat treatment requirements. (a... operations conducted at the facility. In order to be certified, a heat treatment facility must: (1) Have...
7 CFR 305.8 - Heat treatment requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 5 2013-01-01 2013-01-01 false Heat treatment requirements. 305.8 Section 305.8... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS § 305.8 Heat treatment requirements. (a... operations conducted at the facility. In order to be certified, a heat treatment facility must: (1) Have...
7 CFR 305.8 - Heat treatment requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 5 2014-01-01 2014-01-01 false Heat treatment requirements. 305.8 Section 305.8... SERVICE, DEPARTMENT OF AGRICULTURE PHYTOSANITARY TREATMENTS § 305.8 Heat treatment requirements. (a... operations conducted at the facility. In order to be certified, a heat treatment facility must: (1) Have...
Implementation research to improve quality of maternal and newborn health care, Malawi.
Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-07-01
To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.
Advanced High-Level Waste Glass Research and Development Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peeler, David K.; Vienna, John D.; Schweiger, Michael J.
2015-07-01
The U.S. Department of Energy Office of River Protection (ORP) has implemented an integrated program to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product quality requirements. The integrated ORP program is focused on providing a technical, science-based foundation from which key decisions can be made regarding the successful operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) facilities. The fundamental data stemming from this program will support development of advanced glass formulations, key process control models, and tactical processing strategies to ensure safe and successful operations formore » both the low-activity waste (LAW) and high-level waste (HLW) vitrification facilities with an appreciation toward reducing overall mission life. The purpose of this advanced HLW glass research and development plan is to identify the near-, mid-, and longer-term research and development activities required to develop and validate advanced HLW glasses and their associated models to support facility operations at WTP, including both direct feed and full pretreatment flowsheets. This plan also integrates technical support of facility operations and waste qualification activities to show the interdependence of these activities with the advanced waste glass (AWG) program to support the full WTP mission. Figure ES-1 shows these key ORP programmatic activities and their interfaces with both WTP facility operations and qualification needs. The plan is a living document that will be updated to reflect key advancements and mission strategy changes. The research outlined here is motivated by the potential for substantial economic benefits (e.g., significant increases in waste throughput and reductions in glass volumes) that will be realized when advancements in glass formulation continue and models supporting facility operations are implemented. Developing and applying advanced glass formulations will reduce the cost of Hanford tank waste management by reducing the schedule for tank waste treatment and reducing the amount of HLW glass for storage, transportation, and disposal. Additional benefits will be realized if advanced glasses are developed that demonstrate more tolerance for key components in the waste (such as Al 2O 3, Cr 2O 3, SO 3 and Na 2O) above the currently defined WTP constraints. Tolerating these higher concentrations of key waste loading limiters may reduce the burden on (or even eliminate the need for) leaching to remove Cr and Al and washing to remove excess S and Na from the HLW fraction. Advanced glass formulations may also make direct vitrification of the HLW fraction without significant pretreatment more cost effective. Finally, the advanced glass formulation efforts seek not only to increase waste loading in glass, but also to increase glass production rate. When coupled with higher waste loading, ensuring that all of the advanced glass formulations are processable at or above the current contract processing rate leads to significant improvements in waste throughput (the amount of waste being processed per unit time),which could significantly reduce the overall WTP mission life. The integration of increased waste loading, reduced leaching/washing requirements, and improved melting rates provides a system-wide approach to improve the effectiveness of the WTP process.« less
Phillips, Rebecca B; James, Ryan R; Magnuson, Matthew L
2018-04-01
Intentional and unintentional contamination incidents, such as terrorist attacks, natural disasters, and accidental spills, can result in large volumes of contaminated water. These waters may require pre-treatment before disposal and assurances that treated waters will not adversely impact biological processes at wastewater treatment facilities, or receiving waters. Based on recommendations of an industrial workgroup, this study addresses such concerns by studying electrochemical advanced oxidation process (EAOP) pre-treatment for contaminated waters, using a boron-doped diamond (BDD) anode, prior to discharge to wastewater treatment facilities. Reaction conditions were investigated, and microbial toxicity was assessed using the Microtox ® toxicity assay and the Nitrification Inhibition test. A range of contaminants were studied including herbicides, pesticides, pharmaceuticals and flame retardants. Resulting toxicities varied with supporting electrolyte from 5% to 92%, often increasing, indicating that microbial toxicity, in addition to parent compound degradation, should be monitored during treatment. These toxicity results are particularly novel because they systematically compare the microbial toxicity effects of a variety of supporting electrolytes, indicating some electrolytes may not be appropriate in certain applications. Further, these results are the first known report of the use of the Nitrification Inhibition test for this application. Overall, these results systematically demonstrate that anodic oxidation using the BDD anode is useful for addressing water contaminated with refractory organic contaminants, while minimizing impacts to wastewater plants or receiving waters accepting EAOP-treated effluent. The results of this study indicate nitrate can be a suitable electrolyte for incident response and, more importantly, serve as a baseline for site specific EAOP usage. Copyright © 2018 Elsevier Ltd. All rights reserved.
40 CFR 52.279 - Food processing facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 3 2012-07-01 2012-07-01 false Food processing facilities. 52.279... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.279 Food processing facilities... emissions from food processing facilities without any accompanying analyses demonstrating that these...
40 CFR 52.279 - Food processing facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 3 2014-07-01 2014-07-01 false Food processing facilities. 52.279... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.279 Food processing facilities... emissions from food processing facilities without any accompanying analyses demonstrating that these...
40 CFR 52.279 - Food processing facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 3 2011-07-01 2011-07-01 false Food processing facilities. 52.279... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.279 Food processing facilities... emissions from food processing facilities without any accompanying analyses demonstrating that these...
40 CFR 52.279 - Food processing facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... emissions from food processing facilities without any accompanying analyses demonstrating that these... 40 Protection of Environment 3 2013-07-01 2013-07-01 false Food processing facilities. 52.279... (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS California § 52.279 Food processing facilities...
PROGRESS WITH K BASINS SLUDGE RETRIEVAL STABILIZATION & PACKAGING AT THE HANFORD NUCLEAR SITE
DOE Office of Scientific and Technical Information (OSTI.GOV)
KNOLLMEYER, P.M.; PHILLIPS, C; TOWNSON, P.S.
This paper shows how Fluor Hanford and BNG America have combined nuclear plant skills from the U.S. and the U.K. to devise methods to retrieve and treat the sludge that has accumulated in K Basins at the Hanford Site over many years. Retrieving the sludge is the final stage in removing fuel and sludge from the basins to allow them to be decontaminated and decommissioned, so as to remove the threat of contamination of the Columbia River. A description is given of sludge retrieval using vacuum lances and specially developed nozzles and pumps into Consolidation Containers within the basins. Themore » special attention that had to be paid to the heat generation and potential criticality issues with the irradiated uranium-containing sludge is described. The processes developed to re-mobilize the sludge from the Consolidation Containers and pump it through flexible and transportable hose-in-hose piping to the treatment facility are explained with particular note made of dealing with the abrasive nature of the sludge. The treatment facility, housed in an existing Hanford building, is described, and the uranium-corrosion and grout packaging processes explained. The uranium corrosion process is a robust, tempered process very suitable for dealing with a range of differing sludge compositions. Optimization and simplification of the original sludge corrosion process design is described and the use of transportable and reusable equipment is indicated. The processes and techniques described in the paper are shown to have wide applicability to nuclear cleanup.« less
Total energy food plant 21 million gallon ethanol facility
NASA Astrophysics Data System (ADS)
1981-10-01
The Phase I Engineering study includes the following: process description, waste water treatment plant, material summary, energy chart, capital cost estimate, equipment list, personnel requirements, drawings list, specifications list, and project schedule. The economic and financial feasibility of the technical process, and environmental, health, safety, and socio-economic assessments for the project are reported. The costs for extending the following utilities to the property line of the selected site are presented: potable water, sewer system, electricity, roads for truck traffic, and rail service.
NASA Astrophysics Data System (ADS)
1982-02-01
The concepts of the roles of heat and temperature, ventilation and water removal when organic material is assembled into a self insulating mass are summarized. The practical application of these concepts in static pile configuration or the Rutgers process are outlined. The concepts and means of application are relevant to all design approaches whether or not a reactor structure is involved, whether the process is batch or continuous, and whether the mass is agitated or static.
Shreay, Sanatan; Ma, Martin; McCluskey, Jill; Mittelhammer, Ron C; Gitlin, Matthew; Stephens, J Mark
2014-01-01
Objective To explore the relative efficiency of dialysis facilities in the United States and identify factors that are associated with efficiency in the production of dialysis treatments. Data Sources/Study Setting Medicare cost report data from 4,343 free-standing dialysis facilities in the United States that offered in-center hemodialysis in 2010. Study Design A cross-sectional, facility-level retrospective database analysis, utilizing data envelopment analysis (DEA) to estimate facility efficiency. Data Collection/Extraction Methods Treatment data and cost and labor inputs of dialysis treatments were obtained from 2010 Medicare Renal Cost Reports. Demographic data were obtained from the 2010 U.S. Census. Principal Findings Only 26.6 percent of facilities were technically efficient. Neither the intensity of market competition nor the profit status of the facility had a significant effect on efficiency. Facilities that were members of large chains were less likely to be efficient. Cost and labor savings due to changes in drug protocols had little effect on overall dialysis center efficiency. Conclusions The majority of free-standing dialysis facilities in the United States were functioning in a technically inefficient manner. As payment systems increasingly employ capitation and bundling provisions, these institutions will need to evaluate their efficiency to remain competitive. PMID:24237043
Need for improvements in physical pretreatment of source-separated household food waste.
Bernstad, A; Malmquist, L; Truedsson, C; la Cour Jansen, J
2013-03-01
The aim of the present study was to investigate the efficiency in physical pretreatment processes of source-separated solid organic household waste. The investigation of seventeen Swedish full-scale pretreatment facilities, currently receiving separately collected food waste from household for subsequent anaerobic digestion, shows that problems with the quality of produced biomass and high maintenance costs are common. Four full-scale physical pretreatment plants, three using screwpress technology and one using dispergation technology, were compared in relation to resource efficiency, losses of nitrogen and potential methane production from biodegradable matter as well as the ratio of unwanted materials in produced biomass intended for wet anaerobic digestion. Refuse generated in the processes represent 13-39% of TS in incoming wet waste. The methane yield from these fractions corresponds to 14-36Nm(3)/ton separately collected solid organic household waste. Also, 13-32% of N-tot in incoming food waste is found in refuse. Losses of both biodegradable material and nutrients were larger in the three facilities using screwpress technology compared to the facility using dispersion technology.(1) Thus, there are large potentials for increase of both the methane yield and nutrient recovery from separately collected solid organic household waste through increased efficiency in facilities for physical pretreatment. Improved pretreatment processes could thereby increase the overall environmental benefits from anaerobic digestion as a treatment alternative for solid organic household waste. Copyright © 2012 Elsevier Ltd. All rights reserved.
Biochar from Biosolids Pyrolysis: A Review.
Paz-Ferreiro, Jorge; Nieto, Aurora; Méndez, Ana; Askeland, Matthew Peter James; Gascó, Gabriel
2018-05-10
Ever increasing volumes of biosolids (treated sewage sludge) are being produced by municipal wastewater facilities. This is a consequence of the continued expansion of urban areas, which in turn require the commissioning of new treatment plants or upgrades to existing facilities. Biosolids contain nutrients and energy which can be used in agriculture or waste-to-energy processes. Biosolids have been disposed of in landfills, but there is an increasing pressure from regulators to phase out landfilling. This article performs a critical review on options for the management of biosolids with a focus on pyrolysis and the application of the solid fraction of pyrolysis (biochar) into soil.
Biochar from Biosolids Pyrolysis: A Review
Nieto, Aurora; Méndez, Ana; Askeland, Matthew Peter James; Gascó, Gabriel
2018-01-01
Ever increasing volumes of biosolids (treated sewage sludge) are being produced by municipal wastewater facilities. This is a consequence of the continued expansion of urban areas, which in turn require the commissioning of new treatment plants or upgrades to existing facilities. Biosolids contain nutrients and energy which can be used in agriculture or waste-to-energy processes. Biosolids have been disposed of in landfills, but there is an increasing pressure from regulators to phase out landfilling. This article performs a critical review on options for the management of biosolids with a focus on pyrolysis and the application of the solid fraction of pyrolysis (biochar) into soil. PMID:29748488
40 CFR 35.917-5 - Public participation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... identification and evaluation of locations for waste water treatment facilities and of alternative treatment... treatment, reduce waste water volume, and encourage multiple use of facilities; (3) The evaluation of social... planning issues and decisions. (b) Basic Public Participation Program. Since waste water treatment...
Wang, Feng; Huisman, Jaco; Meskers, Christina E M; Schluep, Mathias; Stevels, Ab; Hagelüken, Christian
2012-11-01
E-waste is a complex waste category containing both hazardous and valuable substances. It demands for a cost-efficient treatment system which simultaneously liberates and refines target fractions in an environmentally sound way. In most developing countries there is a lack of systems covering all steps from disposal until final processing due to limited infrastructure and access to technologies and investment. This paper introduces the 'Best-of-2-Worlds' philosophy (Bo2W), which provides a network and pragmatic solution for e-waste treatment in emerging economies. It seeks technical and logistic integration of 'best' pre-processing in developing countries to manually dismantle e-waste and 'best' end-processing to treat hazardous and complex fractions in international state-of-the-art end-processing facilities. A series of dismantling trials was conducted on waste desktop computers, IT equipment, large and small household appliances, in order to compare the environmental and economic performances of the Bo2W philosophy with other conventional recycling scenarios. The assessment showed that the performance of the Bo2W scenario is more eco-efficient than mechanical separation scenarios and other local treatment solutions. For equipment containing substantial hazardous substances, it demands the assistance from domestic legislation for mandatory removal and safe handling of such fractions together with proper financing to cover the costs. Experience from Bo2W pilot projects in China and India highlighted key societal factors influencing successful implementation. These include market size, informal competitors, availability of national e-waste legislation, formal take-back systems, financing and trust between industrial players. The Bo2W philosophy can serve as a pragmatic and environmentally responsible transition before establishment of end-processing facilities in developing countries is made feasible. The executive models of Bo2W should be flexibly differentiated for various countries by adjusting to local conditions related to operational scale, level of centralized operations, dismantling depth, combination with mechanical processing and optimized logistics to international end-processors. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pyatanova, P. A.; Adeeva, L. N.
2017-08-01
It was elaborated the ability of the sorbent produced by thermic treatment of cedar nut shell to destruct model and real first kind (direct) emulsions in static and dynamic conditions. In static conditions optimal ratio sorbent-emulsion with the original concentration of oil products 800 mg/l was in the range of 2.0 g per 100 ml of emulsion which corresponds to the level of treatment 94.9%. The time of emulsion destruction was 40 minutes. This sorbent is highly active in dynamic processes of oil-contaminated water treatment, the level of treatment 96.0% is being achieved. Full dynamic sorptive capacity of the sorbent is 0.85 g/g. Sorbent based on the thermic treated cedar nut shell can be elaborated as sorptive filter element of local treatment facilities of oil refining and petrochemical processes. After the treatment with this sorbent of drainage waters of oil refinery in dynamic conditions the concentration of oil products became less than mpc on oil products for waste waters coming to biological treatment.
Jha, Paridhi; Christensson, Kyllike; Svanberg, Agneta Skoog; Larsson, Margareta; Sharma, Bharati; Johansson, Eva
2016-08-01
this study aimed to explore and understand the perceptions and experiences of women regarding quality of care received during childbirth in public health facilities. qualitative in-depth interviews were conducted and analysed using the Grounded Theory approach. thirteen women who had given vaginal birth to a healthy newborn infant. participants were interviewed in their homes in one district of Chhattisgarh, India. the interview followed a pre-tested guide comprising one key question: How did the women experience and perceive the care provided during labour and childbirth? 'cashless childbirth but at a cost: subordination during childbirth' was identified as the core category. Women chose a public health facility due to their socio-economic limitations, and to have a cashless and safe childbirth. Participants expressed a sense of trust in public health facilities, and verbalised that free food and ambulance services provided by the government were appreciated. Care during normal birth was medicalised, and women lacked control over the process of their labour. Often, the women experienced verbal and physical abuse, which led to passive acceptance of all the services provided to avoid confrontation with the providers. increasingly higher numbers of women give birth in public health facilities in Chhattisgarh, India, and women who have no alternative place to have a safe and normal birth are the main beneficiaries. The labour rooms are functional, but there is a need for improvement of interpersonal processes, information-sharing, and sensitive treatment of women seeking childbirth services in public health facilities. Copyright © 2016 Elsevier Ltd. All rights reserved.
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 15 Commerce and Foreign Trade 3 2012-01-01 2012-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 15 Commerce and Foreign Trade 3 2013-01-01 2013-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
15 CFR 923.13 - Energy facility planning process.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Energy facility planning process. 923... RESOURCE MANAGEMENT COASTAL ZONE MANAGEMENT PROGRAM REGULATIONS Uses Subject to Management § 923.13 Energy facility planning process. The management program must contain a planning process for energy facilities...
B Plant Complex preclosure work plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
ADLER, J.G.
1999-02-02
This preclosure work plan describes the condition of the dangerous waste treatment storage, and/or disposal (TSD) unit after completion of the B Plant Complex decommissioning Transition Phase preclosure activities. This description includes waste characteristics, waste types, locations, and associated hazards. The goal to be met by the Transition Phase preclosure activities is to place the TSD unit into a safe and environmentally secure condition for the long-term Surveillance and Maintenance (S&M) Phase of the facility decommissioning process. This preclosure work plan has been prepared in accordance with Section 8.0 of the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement)more » (Ecology et al. 1996). The preclosure work plan is one of three critical Transition Phase documents, the other two being: B Plant End Points Document (WHC-SD-WM-TPP-054) and B Plant S&M plan. These documents are prepared by the U.S. Department of Energy, Richland Operations Office (DOE-RL) and its contractors with the involvement of Washington State Department of Ecology (Ecology). The tanks and vessels addressed by this preclosure work plan are limited to those tanks end vessels included on the B Plant Complex Part A, Form 3, Permit Application (DOE/RL-88-21). The criteria for determining which tanks or vessels are in the Part A, Form 3, are discussed in the following. The closure plan for the TSD unit will not be prepared until the Disposition Phase of the facility decommissioning process is initiated, which follows the long-term S&M Phase. Final closure will occur during the Disposition Phase of the facility decommissioning process. The Waste Encapsulation Storage Facility (WESF) is excluded from the scope of this preclosure work plan.« less
Patient handling system for carbon ion beam scanning therapy
Shirai, Toshiyuki; Takei, Yuka; Furukawa, Takuji; Inaniwa, Taku; Matsuzaki, Yuka; Kumagai, Motoki; Murakami, Takeshi; Noda, Koji
2012-01-01
Our institution established a new treatment facility for carbon ion beam scanning therapy in 2010. The major advantages of scanning beam treatment compared to the passive beam treatment are the following: high dose conformation with less excessive dose to the normal tissues, no bolus compensator and patient collimator/ multi‐leaf collimator, better dose efficiency by reducing the number of scatters. The new facility was designed to solve several problems encountered in the existing facility, at which several thousand patients were treated over more than 15 years. Here, we introduce the patient handling system in the new treatment facility. The new facility incorporates three main systems, a scanning irradiation system (S‐IR), treatment planning system (TPS), and patient handling system (PTH). The PTH covers a wide range of functions including imaging, geometrical/position accuracy including motion management (immobilization, robotic arm treatment bed), layout of the treatment room, treatment workflow, software, and others. The first clinical trials without respiratory gating have been successfully started. The PTH allows a reduction in patient stay in the treatment room to as few as 7 min. The PTH plays an important role in carbon ion beam scanning therapy at the new institution, particularly in the management of patient handling, application of image‐guided therapy, and improvement of treatment workflow, and thereby allows substantially better treatment at minimum cost. PACS numbers: 87.56.‐v; 87.57.‐s; 87.55.‐x PMID:23149784
Influence of water quality on the embodied energy of drinking water treatment.
Santana, Mark V E; Zhang, Qiong; Mihelcic, James R
2014-01-01
Urban water treatment plants rely on energy intensive processes to provide safe, reliable water to users. Changes in influent water quality may alter the operation of a water treatment plant and its associated energy use or embodied energy. Therefore the objective of this study is to estimate the effect of influent water quality on the operational embodied energy of drinking water, using the city of Tampa, Florida as a case study. Water quality and water treatment data were obtained from the David L Tippin Water Treatment Facility (Tippin WTF). Life cycle energy analysis (LCEA) was conducted to calculate treatment chemical embodied energy values. Statistical methods including Pearson's correlation, linear regression, and relative importance were used to determine the influence of water quality on treatment plant operation and subsequently, embodied energy. Results showed that influent water quality was responsible for about 14.5% of the total operational embodied energy, mainly due to changes in treatment chemical dosages. The method used in this study can be applied to other urban drinking water contexts to determine if drinking water source quality control or modification of treatment processes will significantly minimize drinking water treatment embodied energy.
An evaluation of three experimental processes for two-dimensional transonic tests
NASA Technical Reports Server (NTRS)
Zuppardi, Gennaro
1989-01-01
The aerodynamic measurements in conventional wind tunnels usually suffer from the interference effects of the sting supporting the model and the test section walls. These effects are particularly severe in the transonic regime. Sting interference effects can be overcome through the Magnetic Suspension technique. Wall effects can be alleviated by: testing airfoils in conventional, ventilated tunnels at relatively small model to tunnel size ratios; treatment of the tunnel wall boundary layers; or by utilization of the Adaptive Wall Test Section (AWTS) concept. The operating capabilities and results from two of the foremost two-dimensional, transonic, AWTS facilities in existence are assessed. These facilities are the NASA 0.3-Meter Transonic Cryogenic Tunnel and the ONERA T-2 facility located in Toulouse, France. In addition, the results derived from the well known conventional facility, the NAE 5 ft x 5 ft Canadian wind tunnel will be assessed. CAST10/D0A2 Airfoil results will be used in all of the evaluations.
Office of River Protection Advanced Low-Activity Waste Glass Research and Development Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kruger, A. A.; Peeler, D. K.; Kim, D. S.
2015-11-23
The U.S. Department of Energy Office of River Protection (ORP) has initiated and leads an integrated Advanced Waste Glass (AWG) program to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product performance requirements. The integrated ORP program is focused on providing a technical, science-based foundation for making key decisions regarding the successful operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) facilities in the context of an optimized River Protection Project (RPP) flowsheet. The fundamental data stemming from this program will support development of advanced glass formulations, keymore » product performance and process control models, and tactical processing strategies to ensure safe and successful operations for both the low-activity waste (LAW) and high-level waste vitrification facilities. These activities will be conducted with the objective of improving the overall RPP mission by enhancing flexibility and reducing cost and schedule.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... statute, in a correctional or rehabilitative facility, including a mental hospital or other facility for the care and treatment of mental illness, or (2) confined, under a voluntary commitment, in a mental hospital or other facility for the care and treatment of mental illness. Mentally incompetent individual...
Cohn, Amy; Stanton, Cassandra; Elmasry, Hoda; Ehlke, Sarah; Niaura, Ray
2016-06-01
Substance use disorders are common among persons with HIV/AIDS. This study examined the prevalence and correlates of the provision of four HIV services in a national sample of substance abuse treatment facilities. Data were from the 2011 National Survey of Substance Abuse Treatment Services. Prevalence estimates indicated that 28% of facilities offered HIV testing, 26% early intervention, 58% HIV/AIDS education, and 8% special programs for HIV/AIDS. Facilities offering inpatient substance abuse care were more than six times as likely to offer HIV testing but not more likely to offer any other type of HIV service. Facilities offering methadone treatment were 2.5 times more likely to offer HIV services. Given the high rates of substance use among persons with HIV, the prevalence of facilities offering HIV services was low in most domains, with different barriers identified in multivariable models. Integrating comprehensive HIV prevention, testing, and support services into programs that address substance abuse is needed.
Availability of Youth Services in U.S. Mental Health Treatment Facilities
Cummings, Janet R.; Case, Brady G.; Ji, Xu; Marcus, Steven C.
2015-01-01
Despite concern about access to mental health (MH) services for youth, little is known about the specialty treatment infrastructure serving this population. We used national data to examine which types of MH treatment facilities (hospital- and community-based) were most likely to offer youth services and which types of communities were most likely to have this infrastructure. Larger (p<0.001) and privately owned (p<0.001) facilities were more likely to offer youth services. Rural counties, counties in which a majority of residents were nonwhite, and/or counties with a higher percentage of uninsured residents were less likely to have a community-based MH treatment facility that served youth (p<0.001). PMID:26467795
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckman, John C.
2012-07-01
A water treatment system at a United States Environmental Protection Agency (USEPA) Superfund site impacted by radiological contaminants is used to treat water entering the site. The United States Army Corps of Engineers (USACE) is actively managing the remedial action for the USEPA using contracts to support the multiple activities on site. The site is where former gas mantle production facilities operated around the turn of the century. The manufacturing facilities used thorium ores to develop the mantles and disposed of off-specification mantles and ore residuals in the surrounding areas. During Site remedial actions, both groundwater and surface water comesmore » into contact with contaminated soils and must be collected and treated at an on-site treatment facility. The radionuclides thorium and radium with associated progeny are the main concern for treatment. Suspended solids, volatile organic compounds, and select metals are also monitored during water treatment. The water treatment process begins were water is pumped to a collection tank where debris and grit settle out. Stored water is pumped to a coagulant tank containing poly-aluminum chloride to collect dissolved solids. The water passes into a reaction tube where aspirated air is added or reagent added to remove Volatile Organic Compounds (VOC'S) by mass transfer and convert dissolved iron to a solid. The water enters the flocculent polymer tank to drop solids out. The flocculated water overflows to a fluidized bed contact chamber to increase precipitation. Flocculation is where colloids of material drop out of suspension and settle. The settled solids are periodically removed and disposed of as radioactive waste. The water is passed through filters and an ion exchange process to extract the radionuclides. Several million liters of water are processed each year from two water treatment plants servicing different areas of the remediation site. Ion exchange resin and filter material are periodically replaced and disposed of as radioactive waste. A total of 0.85 m{sup 3} of waste sludge per year requires disposal on average, in addition to another 6.6 m{sup 3} of waste cartridge filters. All water discharges are regulated by a state of New Jersey Pollutant Discharge Elimination System Permit implemented by the Federal Water Pollution Control Act (Clean Water Act). Laboratory analyses are required to satisfy requirements of the state NPDES permit. Specific monitoring parameters and discharge rates will be provided. Use of the water treatment systems drastically reduces the amount of contaminated water requiring solidification and water disposal to near zero. Millions of liters of potentially contaminated water from excavation activities is treated and released within permit limits. A small volume of solid radioactive waste (21 cubic meters) is generated annually from water treatment process operations. Management of ground and surface water is effectively controlled in remediation areas by the use of sumps, erosion control measures and pumping of water to storage vessels. Continued excavations can be made as water impacting the site is effectively controlled. (authors)« less
Shafer, Michael S.; Dembo, Richard; del Mar Vega-Debién, Graciela; Pankow, Jennifer; Duvall, Jamieson L.; Belenko, Steven; Frisman, Linda K.; Visher, Christy A.; Pich, Michele; Patterson, Yvonne
2014-01-01
Objectives. We tested a modified Network for the Improvement of Addiction Treatment (NIATx) process improvement model to implement improved HIV services (prevention, testing, and linkage to treatment) for offenders under correctional supervision. Methods. As part of the Criminal Justice Drug Abuse Treatment Studies, Phase 2, the HIV Services and Treatment Implementation in Corrections study conducted 14 cluster-randomized trials in 2011 to 2013 at 9 US sites, where one correctional facility received training in HIV services and coaching in a modified NIATx model and the other received only HIV training. The outcome measure was the odds of successful delivery of an HIV service. Results. The results were significant at the .05 level, and the point estimate for the odds ratio was 2.14. Although overall the results were heterogeneous, the experiments that focused on implementing HIV prevention interventions had a 95% confidence interval that exceeded the no-difference point. Conclusions. Our results demonstrate that a modified NIATx process improvement model can effectively implement improved rates of delivery of some types of HIV services in correctional environments. PMID:25322311
Pearson, Frank S; Shafer, Michael S; Dembo, Richard; Del Mar Vega-Debién, Graciela; Pankow, Jennifer; Duvall, Jamieson L; Belenko, Steven; Frisman, Linda K; Visher, Christy A; Pich, Michele; Patterson, Yvonne
2014-12-01
We tested a modified Network for the Improvement of Addiction Treatment (NIATx) process improvement model to implement improved HIV services (prevention, testing, and linkage to treatment) for offenders under correctional supervision. As part of the Criminal Justice Drug Abuse Treatment Studies, Phase 2, the HIV Services and Treatment Implementation in Corrections study conducted 14 cluster-randomized trials in 2011 to 2013 at 9 US sites, where one correctional facility received training in HIV services and coaching in a modified NIATx model and the other received only HIV training. The outcome measure was the odds of successful delivery of an HIV service. The results were significant at the .05 level, and the point estimate for the odds ratio was 2.14. Although overall the results were heterogeneous, the experiments that focused on implementing HIV prevention interventions had a 95% confidence interval that exceeded the no-difference point. Our results demonstrate that a modified NIATx process improvement model can effectively implement improved rates of delivery of some types of HIV services in correctional environments.
Ferrell, G.M.
2009-01-01
Samples of treated effluent and treated and untreated water were collected at 20 municipal wastewater and drinkingwater treatment facilities in the Tar and Cape Fear River basins of North Carolina during 2003 and 2005. The samples were analyzed for a variety of prescription and nonprescription pharmaceutical compounds and a suite of organic compounds considered indicative of wastewater. Concentrations of these compounds generally were less than or near the detection limits of the analytical methods used during this investigation. None of these compounds were detected at concentrations that exceeded drinking-water standards established by the U.S. Environmental Protection Agency. Bromoform, a disinfection byproduct, was the only compound detected at a concentration that exceeded regulatory guidelines. The concentration of bromoform in one finished drinking-water sample, 26 micrograms per liter, exceeded North Carolina water-quality criteria. Drinking-water treatment practices were effective at removing many of the compounds detected in untreated water. Disinfection processes used in wastewater treatment - chlorination or irradiation with ultraviolet light - did not seem to substantially degrade the organic compounds evaluated during this study.
Yang, Yi; Ok, Yong Sik; Kim, Ki-Hyun; Kwon, Eilhann E; Tsang, Yiu Fai
2017-10-15
In recent years, many of micropollutants have been widely detected because of continuous input of pharmaceuticals and personal care products (PPCPs) into the environment and newly developed state-of-the-art analytical methods. PPCP residues are frequently detected in drinking water sources, sewage treatment plants (STPs), and water treatment plants (WTPs) due to their universal consumption, low human metabolic capability, and improper disposal. When partially metabolized PPCPs are transferred into STPs, they elicit negative effects on biological treatment processes; therefore, conventional STPs are insufficient when it comes to PPCP removal. Furthermore, the excreted metabolites may become secondary pollutants and can be further modified in receiving water bodies. Several advanced treatment systems, including membrane filtration, granular activated carbon, and advanced oxidation processes, have been used for the effective removal of individual PPCPs. This review covers the occurrence patterns of PPCPs in water environments and the techniques adopted for their treatment in STP/WTP unit processes operating in various countries. The aim of this review is to provide a comprehensive summary of the removal and fate of PPCPs in different treatment facilities as well as the optimum methods for their elimination in STP and WTP systems. Copyright © 2017 Elsevier B.V. All rights reserved.
Megerso, Abebe; Garoma, Sileshi
2016-10-18
Antiretroviral treatment (ART) service scaling up has been practiced in the Ethiopia since 2006. Regardless of increasing number of primary health care centers providing the service, the existing hospitals are still overcrowded with ART service seeking patients may be because of the common belief that treatment outcome is better for hospital patients than those treated at the primary health centers. However, documented evidence comparing the treatment outcome for the two categories of health facilities is scarce in the study setting. The purpose of the current study was to compare major treatment outcomes among new patients treated at the two health facility categories. Retrospective cohort study was implemented using secondary data from medical records collected between October 2010 and January 2014 in the selected health facilities. All patients (1895) who started the treatment in the facilities during the period were included in the study. Univariate analyses were made using descriptive methods such as frequency distributions and measures of central tendency. Bivariate and multivariate analyses were made using Kaplan Meier and Cox regression models respectively to compare the mean survival time between the two facility categories. P-value less than 0.05 was considered as statistically significant. A total of 1895 patient records were followed for 27,990 person-months. Risks of unwanted treatment outcomes (death and lose-to-follow-up) were the same for both categories of patients. The median survival probability was similar to the facility categories (P-value = 0.11). Baseline performance scale III/IV (AHR, 2.4; 95 % CI: 2.0, 3.0), baseline WHO clinical stages III/IV (AHR, 2.8; 95 % CI: 2.3, 3.4), and low adherence (<95 %) to ART drugs (AHR, 3.4; 95 % CI: 2.8, 5.2) were the independent predictors of the unwanted treatment outcomes. Antiretroviral treatment service delivery at primary health care facilities did not compromise the treatment outcomes among adult ART naïve patients. This implies that, ART services decentralization can result in acceptable treatment outcome in less developed settings. Therefore, treatment requiring patients should be encouraged to start the treatment in either of the health facilities as early as possible.
Long-stay in short-stay inpatient facilities: risk factors and barriers to discharge
Gigantesco, Antonella; de Girolamo, Giovanni; Santone, Giovanni; Miglio, Rossella; Picardi, Angelo
2009-01-01
Background The aim of the present study was to assess the characteristics of long-stay inpatients in public and private Italian acute inpatient facilities, to identify risk factors and correlates of the long duration of hospital stay in these patients, and to identify possible barriers to alternative placements. Methods All patients in 130 Italian public and private psychiatric inpatient units who had been hospitalized for more than 3 months during a specific index period were assessed with standardized assessment instruments and compared to patients discharged during the same index period, but staying in hospital for less than 3 months (short-stay inpatients). Assessed domains included demographic, clinical, and treatment characteristics, as well as process of care. Logistic regression analysis was used to identify specific variables predicting inpatient long-stay status. Reasons for delaying patient discharge, as reported by treatment teams, were also analyzed. Results No overall differences between long-stay and short-stay patients emerged in terms of symptom severity or diagnostic status. Admission to a private inpatient facility and display of violent behavior during hospital stay were the most powerful predictors of long-stay. Lack of housing and a shortage of community support were the reasons most commonly cited by treatment teams as barriers to discharge. Conclusion Extra-clinical factors are important determinants of prolonged hospitalization in acute inpatient settings. PMID:19698136
Parris Island Wastewater Treatment Plant SCADA Upgrades Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meador, Richard J.; Hatley, Darrel D.
2004-03-18
Marine Corp Recruit Depot (MCRD), Parris Island, SC, home of the Easter Recruiting Region Marine Corp Boot Camp, found itself in a situation common to Department of Defense (DOD) facilities. It had to deal with several different types of installed energy-related control systems that could not talk to each other. This situation was being exacerbated by the installation of a new and/or unique type of control system for every new building being constructed or older facility that was being upgraded. The Wastewater Treatment Facility (WWTF) and lift station controls were badly in need of a thorough inspection and a newmore » Supervisory Control and Data Acquisition (SCADA) system upgrade to meet environmental, safety, manpower, and maintenance concerns. A project was recently completed to implement such a wastewater treatment SCADA upgrade, which is compatible with other upgrades to the energy monitoring and control systems for Parris Island buildings and the Pacific Northwest National Laboratory (PNNL) Decision Support for Operations and Maintenance (DSOM) system installed at the Central Energy Plant (CEP). This project included design, specification, procurement, installation, and testing an upgraded SCADA alarm, process monitoring, and display system; and training WWTF operators in its operation. The ultimate goal of this and the other PNNL projects at Parris Island is to allow monitoring and control of energy and environmental components from a central location.« less
USDA-ARS?s Scientific Manuscript database
Bacterial cross-contamination from the haired outer surface of cattle to the inner meat as well as hide quality deterioration from bacteria are hygienic problems for meat and hide processing facilities. This study investigated spray wash treatments independently with two antimicrobials used in the ...
Renewable Natural Gas Clean-up Challenges and Applications
2011-01-13
produced from digesters ─ Animal manure (dairy cows, swine) ─ Waste water treatment facilities > Methane from Landfills > RNG produced from...AGR used in process • Two stage + trim methanation reactor • Dehydration to achieve gas pipeline specifications ~ 70% conversion efficiency 21... digestion of agricultural waste for on-site electricity generation ─Altamont Landfill—Landfill gas (LFG) cleanup for production of liquefied natural gas
Pamela J. Jakes
2011-01-01
"Iosco jobless rate passes 20 percent" read the headline in the Oscoda Press, February 3, 2010 (Nelson 2010). Although never described as prosperous, in the past, Iosco and neighboring Alcona, Crawford, and Oscoda Counties had benefited from diverse economies, with jobs found in small manufacturing plants, timber harvesting, wood processing facilities, and...
Analysis of Camp Pendleton California Medical Treatment Facility Budget and Execution Process
2008-12-01
for the formal internship, residency, fellowship and graduate training in medicine and dentistry . Graduate Medical Education involves costs of in...Conservation, medical aspects of ergonomics , reproductive hazards, ionizing and non- ionizing radiation safety, workplace assessments (afloat & ashore...care and services to authorized beneficiaries through the operation of hospital departments of dentistry and dental clinics and operation of
A facile and green method towards coal-based fluorescent carbon dots with photocatalytic activity
NASA Astrophysics Data System (ADS)
Hu, Shengliang; Wei, Zhijia; Chang, Qing; Trinchi, Adrian; Yang, Jinlong
2016-08-01
One of the most widely used methods for exfoliating crystalline nanocarbon is via strong oxidizing acid treatment of bulk carbon sources, such as graphite, carbon black and coal. Not only is such method dangerous and accompanied by the liberation of toxic gases, it is also plagued by issues of purity, requiring the thorough and costly removal of the excess oxidizing acids and salts formed during the process. Herein we report a facile, green and inexpensive top-down strategy towards fluorescent carbon dots (CDs) from coal without incurring the burden of tedious or inefficient post-processing steps and facing the danger of highly toxic gas liberation. The presented approach shows a high yield and great potential for carbon dot production scale-up using coal, one of our most abundant and low-cost resources. The prepared CDs demonstrate photocatalytic behavior capable of rapidly degrading organic dyes under visible light. Our findings may lead to alternative uses of coal, particularly for applications including the treatment of environmental pollution, solar energy conversion or storage, and highlight coal's applicability in areas other than energy producing via burning of this great resource.
NASA Technical Reports Server (NTRS)
Robinson, A. C.; Gorman, H. J.; Hillman, M.; Lawhon, W. T.; Maase, D. L.; Mcclure, T. A.
1976-01-01
The potential U.S. market for tertiary municipal wastewater treatment facilities which make use of water hyacinths was investigated. A baseline design was developed which approximates the "typical" or "average" situation under which hyacinth-based systems can be used. The total market size for tertiary treatment was then estimated for those geographical regions in which hyacinths appear to be applicable. Market penetration of the baseline hyacinth system when competing with conventional chemical and physical processing systems was approximated, based primarily on cost differences. A limited analysis was made of the sensitivity of market penetration to individual changes in these assumptions.
Operation and Maintenance of Wastewater Treatment Facilities.
ERIC Educational Resources Information Center
Drury, Douglas D.
1978-01-01
Presents the 1978 literature review of wastewater treatment: (1) operators, training, and certification; (2) solutions to operating problems; (3) collection systems; (4) operations manuals; (5) wastewater treatment facility case histories; (5) land application; and (6) treatment of industrial wastes. A list of 36 references is also presented. (HM)
1999-11-01
Drinking water processing plant , Analysis, Calculation model, Field experiment 16. PRICE CODE 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION...sewage effluents and from the sewer of the municipal sewage treatment plant in Berlin-Ruhleben. In the field trials, the MDWPUs that both apply reverse...waste water samples, along the municipal sewer system and In the influents and effluents of the receiving sewage treatment plants . To estimate the
2011-11-01
Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities By Thomas Krug and Suzanne O’Hara, Geosyntec...COST AND PERFORMANCE REPORT FOR: Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DOD Facilities...11 3.4 Reduction in PCB concentrations in treated paint to less
Background: Combined sewer systems (CSS) collect rainwater runoff, sewage, and industrial wastewater for transit to treatment facilities. With heavy precipitation, volumes can exceed capacity of treatment facilities, and wastewater discharges directly to receiving waters. These c...
Code of Federal Regulations, 2012 CFR
2012-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2011 CFR
2011-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2010 CFR
2010-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2013 CFR
2013-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Code of Federal Regulations, 2014 CFR
2014-07-01
... an energy or mining facility, a storage facility or a seafood processing facility, or when secured to a storage facility or a seafood processing facility, or when secured to the bed of the ocean...
Controlled decomposition and oxidation: A treatment method for gaseous process effluents
NASA Technical Reports Server (NTRS)
Mckinley, Roger J. B., Sr.
1990-01-01
The safe disposal of effluent gases produced by the electronics industry deserves special attention. Due to the hazardous nature of many of the materials used, it is essential to control and treat the reactants and reactant by-products as they are exhausted from the process tool and prior to their release into the manufacturing facility's exhaust system and the atmosphere. Controlled decomposition and oxidation (CDO) is one method of treating effluent gases from thin film deposition processes. CDO equipment applications, field experience, and results of the use of CDO equipment and technological advances gained from the field experiences are discussed.
Facility Volume and Survival in Nasopharyngeal Carcinoma.
Yoshida, Emi J; Luu, Michael; David, John M; Kim, Sungjin; Mita, Alain; Scher, Kevin; Shiao, Stephen L; Tighiouart, Mourad; Lee, Nancy Y; Ho, Allen S; Zumsteg, Zachary S
2018-02-01
Definitive treatment of nasopharyngeal carcinoma (NPC) is challenging owing to its rarity, complicated regional anatomy, and the intensity of therapy. In contrast to other head and neck cancers, the effect of facility volume has not been well described for NPC. The National Cancer Database was queried for patients with stage II-IVB NPC diagnosed from 2004 to 2014 and treated with definitive radiation. Patients with incomplete staging, unknown receipt or timing of treatment, unknown follow-up duration, incomplete socioeconomic information, or treatment outside the reporting facility were excluded. High-volume facilities (HVFs) were defined as the top 5% of facilities according to the annual facility volume. The present analysis included 3941 NPC patients treated at 804 facilities with a median follow-up duration of 59.4 months, including 1025 patients (26.0%) treated at HVFs. Treatment at HVFs was associated with significantly improved overall survival (OS) on multivariable analysis (hazard ratio 0.79, 95% confidence interval 0.69-0.90; P=.001). In propensity score-matched cohorts, 5-year OS was 69.1% versus 63.3% at HVFs versus lower volume facilities (LVFs), respectively (P=.003). Similar results were seen when facility volume was analyzed as a continuous variable. The effect of facility volume on survival varied by academic status (P=.002 for interaction). At academic centers, the propensity score-matched cohorts had 5-year OS of 71.4% compared with 62.4% (P<.001) at HVFs and LVFs, respectively. In contrast, the 5-year OS was 63.5% versus 67.9% (P=.68) in propensity score-matched patients at nonacademic HVFs and LVFs. Treatment at HVFs was associated with improved OS for patients with NPC, with the effect exclusively seen at academic centers. Copyright © 2017 Elsevier Inc. All rights reserved.
Irradiation treatment for the protection and conservation of cultural heritage artefacts in Croatia
NASA Astrophysics Data System (ADS)
Katušin-Ražem, Branka; Ražem, Dušan; Braun, Mario
2009-07-01
The application of irradiation treatment for the protection of cultural heritage artefacts in Croatia was made possible by the development of radiation processing procedures at the Radiation Chemistry and Dosimetry Laboratory of the Ruđer Bo\\vsković Institute. After the upgrading of the 60Co gamma irradiation source in the panoramic irradiation facility in 1983 it became possible to perform both research and pilot plant-scale irradiations for sterilization, pasteurization and decontamination of various materials, including medical supplies, pharmaceuticals, cosmetics and foods, but also for disinfestation of cultural heritage artefects. The demand for irradiation treatment of cultural heritage objects has particularly increased as the increasing number of these objects, especially polychromic wooden sculptures, were requiring salvation, restauration and conservation as a consequence of direct and indirect damages inflicted to them during the war in Croatia, 1991-1995. The irradiation facility at the Ruđer Bo\\vsković Institute is briefly described and an account of its fifteen years' activities in the irradiation treatment of cultural heritage objects is given. Some case studies performed in cooperation with the Croatian Conservation Institute and other interested parties are presented, as well as some cases of protective and curative treatments for disinfestation and decontamination. International cooperations and activities are also mentioned.
Kanyangarara, Mufaro; Walker, Neff; Boerma, Ties
2018-01-01
Syphilis in pregnancy is an under-recognized public health problem, especially in sub-Saharan Africa which accounts for over 60% of the global burden of syphilis. If left untreated, more than half of maternal syphilis cases will result in adverse pregnancy outcomes including stillbirth and fetal loss, neonatal death, prematurity or low birth weight, and neonatal infections. Achieving universal coverage of antenatal syphilis screening and treatment has been the focus of the global campaign for the elimination of mother-to-child transmission of syphilis. However, little is known about the availability of antenatal syphilis screening and treatment across sub-Saharan Africa. The objective of this study was to estimate the 'likelihood of appropriate care' for antenatal syphilis screening and treatment by analyzing health facility surveys and household surveys conducted from 2010 to 2015 in 12 sub-Saharan African countries. In this secondary data analysis, we linked indicators of health facility readiness to provide antenatal syphilis detection and treatment from Service Provision Assessments (SPAs) and Service Availability and Readiness Assessments (SARAs) to indicators of ANC use from the Demographic and Health Surveys (DHS) to compute estimates of the 'likelihood of appropriate care'. Based on data from 5,593 health facilities that reported offering antenatal care (ANC) services, the availability of syphilis detection and treatment in ANC facilities ranged from 2% to 83%. The availability of syphilis detection and treatment was substantially lower in ANC facilities in West Africa compared to the other sub-regions. Levels of ANC attendance were high (median 94.9%), but only 27% of ANC attendees initiated care at less than 4 months gestation. We estimated that about one in twelve pregnant women received ANC early (<4 months) at a facility ready to provide syphilis detection and treatment (median 8%, range 7-32%). The largest implementation bottleneck identified was low health facility readiness, followed by timeliness of the first ANC visit. While access was fairly high, the low levels of likelihood of antenatal syphilis detection and treatment identified reinforce the need to improve the availability of syphilis rapid diagnostic tests and treatment and the timeliness of antenatal care-seeking across sub-Saharan Africa.
Classification methodology for tritiated waste requiring interim storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cana, D.; Dall'ava, D.; Decanis, C.
2015-03-15
Fusion machines like the ITER experimental research facility will use tritium as fuel. Therefore, most of the solid radioactive waste will result not only from activation by 14 MeV neutrons, but also from contamination by tritium. As a consequence, optimizing the treatment process for waste containing tritium (tritiated waste) is a major challenge. This paper summarizes the studies conducted in France within the framework of the French national plan for the management of radioactive materials and waste. The paper recommends a reference program for managing this waste based on its sorting, treatment and packaging by the producer. It also recommendsmore » setting up a 50-year temporary storage facility to allow for tritium decay and designing future disposal facilities using tritiated radwaste characteristics as input data. This paper first describes this waste program and then details an optimized classification methodology which takes into account tritium decay over a 50-year storage period. The paper also describes a specific application for purely tritiated waste and discusses the set-up expected to be implemented for ITER decommissioning waste (current assumption). Comparison between this optimized approach and other viable detritiation techniques will be drawn. (authors)« less
A multi-objective model for sustainable recycling of municipal solid waste.
Mirdar Harijani, Ali; Mansour, Saeed; Karimi, Behrooz
2017-04-01
The efficient management of municipal solid waste is a major problem for large and populated cities. In many countries, the majority of municipal solid waste is landfilled or dumped owing to an inefficient waste management system. Therefore, an optimal and sustainable waste management strategy is needed. This study introduces a recycling and disposal network for sustainable utilisation of municipal solid waste. In order to optimise the network, we develop a multi-objective mixed integer linear programming model in which the economic, environmental and social dimensions of sustainability are concurrently balanced. The model is able to: select the best combination of waste treatment facilities; specify the type, location and capacity of waste treatment facilities; determine the allocation of waste to facilities; consider the transportation of waste and distribution of processed products; maximise the profit of the system; minimise the environmental footprint; maximise the social impacts of the system; and eventually generate an optimal and sustainable configuration for municipal solid waste management. The proposed methodology could be applied to any region around the world. Here, the city of Tehran, Iran, is presented as a real case study to show the applicability of the methodology.
WASTE TREATMENT BUILDING SYSTEM DESCRIPTION DOCUMENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
F. Habashi
2000-06-22
The Waste Treatment Building System provides the space, layout, structures, and embedded subsystems that support the processing of low-level liquid and solid radioactive waste generated within the Monitored Geologic Repository (MGR). The activities conducted in the Waste Treatment Building include sorting, volume reduction, and packaging of dry waste, and collecting, processing, solidification, and packaging of liquid waste. The Waste Treatment Building System is located on the surface within the protected area of the MGR. The Waste Treatment Building System helps maintain a suitable environment for the waste processing and protects the systems within the Waste Treatment Building (WTB) from mostmore » of the natural and induced environments. The WTB also confines contaminants and provides radiological protection to personnel. In addition to the waste processing operations, the Waste Treatment Building System provides space and layout for staging of packaged waste for shipment, industrial and radiological safety systems, control and monitoring of operations, safeguards and security systems, and fire protection, ventilation and utilities systems. The Waste Treatment Building System also provides the required space and layout for maintenance activities, tool storage, and administrative facilities. The Waste Treatment Building System integrates waste processing systems within its protective structure to support the throughput rates established for the MGR. The Waste Treatment Building System also provides shielding, layout, and other design features to help limit personnel radiation exposures to levels which are as low as is reasonably achievable (ALARA). The Waste Treatment Building System interfaces with the Site Generated Radiological Waste Handling System, and with other MGR systems that support the waste processing operations. The Waste Treatment Building System interfaces with the General Site Transportation System, Site Communications System, Site Water System, MGR Site Layout, Safeguards and Security System, Site Radiological Monitoring System, Site Electrical Power System, Site Compressed Air System, and Waste Treatment Building Ventilation System.« less
40 CFR 403.16 - Upset provision.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of... usual exercise of prosecutorial discretion, Agency enforcement personnel should review any claims that...
A review of the technological solutions for the treatment of oily sludges from petroleum refineries.
da Silva, Leonardo Jordão; Alves, Flávia Chaves; de França, Francisca Pessôa
2012-10-01
The activities of the oil industry have several impacts on the environment due to the large amounts of oily wastes that are generated. The oily sludges are a semi-solid material composed by a mixture of clay, silica and iron oxides contaminated with oil, produced water and the chemicals used in the production of oil. Nowadays both the treatment and management of these waste materials is essential to promote sustainable management of exploration and exploitation of natural resources. Biological, physical and chemical processes can be used to reduce environmental contamination by petroleum hydrocarbons to acceptable levels. The choice of treatment method depends on the physical and chemical properties of the waste as well as the availability of facilities to process these wastes. Literature provides some operations for treatment of oily sludges, such as landfilling, incineration, co-processing in clinkerization furnaces, microwave liquefaction, centrifugation, destructive distillation, thermal plasma, low-temperature conversion, incorporation in ceramic materials, development of impermeable materials, encapsulation and biodegradation in land farming, biopiles and bioreactors. The management of the technology to be applied for the treatment of oily wastes is essential to promote proper environmental management, and provide alternative methods to reduce, reuse and recycle the wastes.
Dynamic waste management (DWM): towards an evolutionary decision-making approach.
Rojo, Gabriel; Glaus, Mathias; Laforest, Valerie; Laforest, Valérie; Bourgois, Jacques; Bourgeois, Jacques; Hausler, Robert
2013-12-01
To guarantee sustainable and dynamic waste management, the dynamic waste management approach (DWM) suggests an evolutionary new approach that maintains a constant flow towards the most favourable waste treatment processes (facilities) within a system. To that end, DWM is based on the law of conservation of energy, which allows the balancing of a network, while considering the constraints of incoming (h1 ) and outgoing (h2 ) loads, as well as the distribution network (ΔH) characteristics. The developed approach lies on the identification of the prioritization index (PI) for waste generators (analogy to h1 ), a global allocation index for each of the treatment processes (analogy to h2 ) and the linear index load loss (ΔH) associated with waste transport. To demonstrate the scope of DWM, we outline this approach, and then present an example of its application. The case study shows that the variable monthly waste from the three considered sources is dynamically distributed in priority to the more favourable processes. Moreover, the reserve (stock) helps temporarily store waste in order to ease the global load of the network and favour a constant feeding of the treatment processes. The DWM approach serves as a decision-making tool by evaluating new waste treatment processes, as well as their location and new means of transport for waste.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wheeler, W.
1998-12-01
This report estimates the economic and financial effects and the benefits of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts in terms of changes in the profitability of waste treatment operations at CWT facilities, changes in market prices to CWT services, and changes in the quantities of waste management at CWT facilities in six geographic regions. EPA has also examined the impacts on companies owning CWT facilities (including impacts on small entities), on communities in which CWT facilities are located, and on environmentalmore » justice. EPA examined the benefits to society of the CWT effluent limitations guidelines and standards by examining cancer and non-cancer health effects of the regulation, recreational benefits, and cost savings to publicly owned treatment works (POTWs) to which indirect-discharging CWT facilities send their wastewater.« less
ERIC Educational Resources Information Center
Himes, Dottie
This is an annotated bibliography of wastewater treatment manuals. Fourteen manuals are abstracted including: (1) A Planned Maintenance Management System for Municipal Wastewater Treatment Plants; (2) Anaerobic Sludge Digestion, Operations Manual; (3) Emergency Planning for Municipal Wastewater Treatment Facilities; (4) Estimating Laboratory Needs…
32 CFR 732.18 - Notification of illness or injury.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NONNAVAL MEDICAL AND DENTAL CARE Medical and Dental Care From Nonnaval Sources § 732.18 Notification of... medical or dental attention in a non-Federal facility. The member will also assure (request the facility... or dental facility rendering treatment. (iii) Date(s) of such treatment. (iv) Nature and extent of...
32 CFR 732.18 - Notification of illness or injury.
Code of Federal Regulations, 2014 CFR
2014-07-01
... NONNAVAL MEDICAL AND DENTAL CARE Medical and Dental Care From Nonnaval Sources § 732.18 Notification of... medical or dental attention in a non-Federal facility. The member will also assure (request the facility... or dental facility rendering treatment. (iii) Date(s) of such treatment. (iv) Nature and extent of...
32 CFR 732.18 - Notification of illness or injury.
Code of Federal Regulations, 2012 CFR
2012-07-01
... NONNAVAL MEDICAL AND DENTAL CARE Medical and Dental Care From Nonnaval Sources § 732.18 Notification of... medical or dental attention in a non-Federal facility. The member will also assure (request the facility... or dental facility rendering treatment. (iii) Date(s) of such treatment. (iv) Nature and extent of...
32 CFR 732.18 - Notification of illness or injury.
Code of Federal Regulations, 2011 CFR
2011-07-01
... NONNAVAL MEDICAL AND DENTAL CARE Medical and Dental Care From Nonnaval Sources § 732.18 Notification of... medical or dental attention in a non-Federal facility. The member will also assure (request the facility... or dental facility rendering treatment. (iii) Date(s) of such treatment. (iv) Nature and extent of...
32 CFR 732.18 - Notification of illness or injury.
Code of Federal Regulations, 2013 CFR
2013-07-01
... NONNAVAL MEDICAL AND DENTAL CARE Medical and Dental Care From Nonnaval Sources § 732.18 Notification of... medical or dental attention in a non-Federal facility. The member will also assure (request the facility... or dental facility rendering treatment. (iii) Date(s) of such treatment. (iv) Nature and extent of...
Dairy-impacted wastewater is a source of iodinated disinfection byproducts in the environment
Hladik, Michelle; Hubbard, Laura E.; Kolpin, Dana W.; Focazio, Michael J.
2016-01-01
Iodinated disinfection byproducts (DBPs) are among the most toxic DBPs, but they are not typically measured in treated water. Iodinated DBPs can be toxic to humans, and they also have the potential to affect aquatic communities. Because of the specific use of iodine and iodine-containing compounds in dairies, such livestock operations can be a potential source of iodinated DBPs in corresponding receiving water bodies. DBPs [trihalomethanes (THMs), including iodinated THMs] were measured within dairy processing facilities (milking and cheese manufacturing) and surface waters that receive dairy-impacted effluents [either directly from the dairy or through wastewater treatment plants (WWTPs)] in three areas of the United States (California, New York, and Wisconsin). Iodo-THMs comprised 15−29% of the total THMs in surface water near WWTP effluents that were impacted by dairy waste and 0−100% of the total THMs in samples from dairy processing facilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russell, Renee L.; Fiskum, Sandra K.; Smoot, Margaret R.
Washington River Protection Solutions (WRPS) is developing a Low-Activity Waste Pretreatment System (LAWPS) to provide low-activity waste (LAW) directly to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste Facility for immobilization. The pretreatment that will be conducted on tank waste supernate at the LAWPS facility entails filtration to remove entrained solids and cesium (Cs) ion exchange to remove Cs from the product sent to the WTP. Currently, spherical resorcinol-formaldehyde (sRF) resin (Microbeads AS, Skedsmokorset, Norway) is the Cs ion exchange resin of choice. Most work on Cs ion exchange efficacy in Hanford tank waste has been conductedmore » at nominally 5 M sodium (Na). WRPS is examining the possibility of processing supernatant at high Na concentrations—up to 8 M Na—to maximize processing efficiency through the LAWPS. Minimal Cs ion exchange work has been conducted at 6 M and 8 M Na concentrations..« less
Conceptual design report for the project to install leak detection in FAST-FT-534/548/549
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galloway, K.J.
1992-07-01
This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which ismore » already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.« less
Fate of four phthalate plasticizers under various wastewater treatment processes.
Armstrong, Dana L; Rice, Clifford P; Ramirez, Mark; Torrents, Alba
2018-05-18
The fate of four phthalate plasticizers during wastewater treatment processes at six different wastewater treatment plants (WWTPs) was investigated. Concentrations of benzyl butyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), diisononyl phthalate (DiNP), and diisodecyl phthalate (DiDP) were determined prior to either aerobic or anaerobic (conventional and advanced) treatment, after treatment, and in final, dewatered solids. Despite their elevated use worldwide, the fate of DiNP and DiDP during wastewater treatment have not been well characterized. DEHP was readily degraded during aerobic treatments while anaerobic digestion resulted in either no significant change in concentrations or an increase in concentration, in the case of more advanced anaerobic processes (thermal hydrolysis pretreatment and a two-phase acid/gas process). Impacts of the various treatment systems on DiNP, DiDP, and BBP concentrations were more varied - anaerobic digestion led to significant decreases, increases, or no significant change for these compounds, depending on the treatment facility, while aerobic treatment was generally effective at degrading the compounds. Additionally, thermal hydrolysis pretreatment of sludge prior to anaerobic digestion resulted in increases in DiNP, DiDP, and BBP concentrations. The predicted environmental concentrations for all four compounds in soils after a single biosolids application were calculated and the risk quotients for DEHP in soils were determined. The estimated toxicity risk for DEHP in soils treated with a single application of sludge from any of the six studied WWTPs is lower than the level of concern for acute and chronic risk, as defined by the US EPA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael G. Lewis
2012-02-01
This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site's Central Facilities Area Sewage Treatment Plant from November 1, 2010, through October 31, 2011. The report contains the following information: (1) Site description; (2) Facility and system description; (3) Permit required monitoring data and loading rates; (4) Status of special compliance conditions and activities; and (5) Discussion of the facility's environmental impacts. During the 2011 permit year, approximately 1.22 million gallons of treated wastewater was land-applied to the irrigation area at Central Facilities Areamore » Sewage Treatment plant.« less
Availability of Youth Services in U.S. Mental Health Treatment Facilities.
Cummings, Janet R; Case, Brady G; Ji, Xu; Marcus, Steven C
2016-09-01
Despite concern about access to mental health (MH) services for youth, little is known about the specialty treatment infrastructure serving this population. We used national data to examine which types of MH treatment facilities (hospital- and community-based) were most likely to offer youth services and which types of communities were most likely to have this infrastructure. Larger (p < 0.001) and privately owned (p < 0.001) facilities were more likely to offer youth services. Rural counties, counties in which a majority of residents were nonwhite, and/or counties with a higher percentage of uninsured residents were less likely to have a community-based MH treatment facility that served youth (p < 0.001).
State machine analysis of sensor data from dynamic processes
Cook, William R.; Brabson, John M.; Deland, Sharon M.
2003-12-23
A state machine model analyzes sensor data from dynamic processes at a facility to identify the actual processes that were performed at the facility during a period of interest for the purpose of remote facility inspection. An inspector can further input the expected operations into the state machine model and compare the expected, or declared, processes to the actual processes to identify undeclared processes at the facility. The state machine analysis enables the generation of knowledge about the state of the facility at all levels, from location of physical objects to complex operational concepts. Therefore, the state machine method and apparatus may benefit any agency or business with sensored facilities that stores or manipulates expensive, dangerous, or controlled materials or information.
Jacobson, Jerry O
2006-03-01
Research on drug treatment facility locations has focused narrowly on the issue of geographic proximity to clients. We argue that neighborhood conditions should also enter into the facility location decision and illustrate a formal assessment of neighborhood conditions at facilities in a large, metropolitan area, taking into account conditions clients already face at home. We discuss choice and construction of small-area measures relevant to the drug treatment context, including drug activity, disadvantage, and violence as well as statistical comparisons of clients' home and treatment locations with respect to these measures. Analysis of 22,707 clients discharged from 494 community-based outpatient and residential treatment facilities that received public funds during 1998-2000 in Los Angeles County revealed no significant mean differences between home and treatment neighborhoods. However, up to 20% of clients are exposed to markedly higher levels of disadvantage, violence, or drug activity where they attend treatment than where they live, suggesting that it is not uncommon for treatment locations to increase clients' exposure to potential environmental triggers for relapse. Whereas on average both home and treatment locations exhibit higher levels of these measures than the household locations of the general population, substantial variability in public treatment clients' home neighborhoods calls into question the notion that they hail exclusively from poor, high drug activity areas. Shortcomings of measures available for neighborhood assessment of treatment locations and implications of the findings for other areas of treatment research are also discussed.
Post, Felix; Gori, Tommaso; Senges, Jochen; Giannitsis, Evangelos; Katus, Hugo; Münzel, Thomas
2012-03-01
The establishment of chest pain units (CPUs) in the USA and UK has led to improvements in the prognosis of patients with chest pain and myocardial infarction, optimizing access to specialized diagnostic and therapeutic facilities and reducing costs. To establish a uniform implementation of this type of service in Germany, the German Cardiac Society (DGK) founded a 'CPU task force' in 2007, which developed a set of standard requirements and a nationwide certification programme. The recommendations for minimum standard requirements were published in 2008. As of November 2011, 132 CPUs were certified and 36 units were in the certification process. The aim of the DGK is to certify as many as 250 centres (units) throughout Germany within the next 2 years, to provide nationwide coverage. Applications from Switzerland are also being filed. Public awareness campaigns in cooperation with national league soccer teams were organized to raise awareness of the importance for early diagnosis and treatment of cardiac diseases and to publicize the existence of these new facilities. The German model of CPU certification allows nationwide and prospectively European-wide standardization of patient care and to improve adherence to international guidelines. Coupled with awareness campaigns and with the launch of a German CPU Registry, this process is aimed at improving the education and treatment of patients with chest pain and to provide scientific information about the quality of patient care.
Non-Thermal Treatment of Hanford Site Low-Level Mixed Waste
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
DOE proposes to transport contact-handled LLMW from the Hanford Site to the Allied Technology Group (ATG) Mixed Waste Facility (MWF) in Richland, Washington, for non-thermal treatment and to return the treated waste to the Hanford Site for eventual land disposal. Over a 3-year period the waste would be staged to the ATG MWF, and treated waste would be returned to the Hanford Site. The ATG MWF would be located on an 18 hectare (ha) (45 acre [at]) ATG Site adjacent to ATG's licensed low-level waste processing facility at 2025 Battelle Boulevard. The ATG MWF is located approximately 0.8 kilometers (km)more » (0.5 miles [mi]) south of Horn Rapids Road and 1.6 km (1 mi) west of Stevens Drive. The property is located within the Horn Rapids triangle in northern Richland (Figure 2.1). The ATG MWF is to be located on the existing ATG Site, near the DOE Hanford Site, in an industrial area in the City of Richland. The effects of siting, construction, and overall operation of the MWF have been evaluated in a separate State Environmental Policy Act (SEPA) EIS (City of Richland 1998). The proposed action includes transporting the LLMW from the Hanford Site to the ATG Facility, non-thermal treatment of the LLMW at the ATG MWF, and transporting the waste from ATG back to the Hanford Site. Impacts fi-om waste treatment operations would be bounded by the ATG SEPA EIS, which included an evaluation of the impacts associated with operating the non-thermal portion of the MWF at maximum design capacity (8,500 metric tons per year) (City of Richland 1998). Up to 50 employees would be required for non-thermal treatment portion of the MWF. This includes 40 employees that would perform waste treatment operations and 10 support staff. Similar numbers were projected for the thermal treatment portion of the MWF (City of Richland 1998).« less
SECONDARY WASTE MANAGEMENT FOR HANFORD EARLY LOW ACTIVITY WASTE VITRIFICATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
UNTERREINER BJ
2008-07-18
More than 200 million liters (53 million gallons) of highly radioactive and hazardous waste is stored at the U.S. Department of Energy's Hanford Site in southeastern Washington State. The DOE's Hanford Site River Protection Project (RPP) mission includes tank waste retrieval, waste treatment, waste disposal, and tank farms closure activities. This mission will largely be accomplished by the construction and operation of three large treatment facilities at the Waste Treatment and Immobilization Plant (WTP): (1) a Pretreatment (PT) facility intended to separate the tank waste into High Level Waste (HLW) and Low Activity Waste (LAW); (2) a HLW vitrification facilitymore » intended to immobilize the HLW for disposal at a geologic repository in Yucca Mountain; and (3) a LAW vitrification facility intended to immobilize the LAW for shallow land burial at Hanford's Integrated Disposal Facility (IDF). The LAW facility is on target to be completed in 2014, five years prior to the completion of the rest of the WTP. In order to gain experience in the operation of the LAW vitrification facility, accelerate retrieval from single-shell tank (SST) farms, and hasten the completion of the LAW immobilization, it has been proposed to begin treatment of the low-activity waste five years before the conclusion of the WTP's construction. A challenge with this strategy is that the stream containing the LAW vitrification facility off-gas treatment condensates will not have the option of recycling back to pretreatment, and will instead be treated by the Hanford Effluent Treatment Facility (ETF). Here the off-gas condensates will be immobilized into a secondary waste form; ETF solid waste.« less
Gee, Adrian P.; Richman, Sara; Durett, April; McKenna, David; Traverse, Jay; Henry, Timothy; Fisk, Diann; Pepine, Carl; Bloom, Jeannette; Willerson, James; Prater, Karen; Zhao, David; Koç, Jane Reese; Ellis, Steven; Taylor, Doris; Cogle, Christopher; Moyé, Lemuel; Simari, Robert; Skarlatos, Sonia
2013-01-01
Background Aims Multi-center cellular therapy clinical trials require the establishment and implementation of standardized cell processing protocols and associated quality control mechanisms. The aims here were to develop such an infrastructure in support of the Cardiovascular Cell Therapy Research Network (CCTRN) and to report on the results of processing for the first 60 patients. Methods Standardized cell preparations, consisting of autologous bone marrow mononuclear cells, prepared using the Sepax device were manufactured at each of the five processing facilities that supported the clinical treatment centers. Processing staff underwent centralized training that included proficiency evaluation. Quality was subsequently monitored by a central quality control program that included product evaluation by the CCTRN biorepositories. Results Data from the first 60 procedures demonstrate that uniform products, that met all release criteria, could be manufactured at all five sites within 7 hours of receipt of the bone marrow. Uniformity was facilitated by use of the automated systems (the Sepax for processing and the Endosafe device for endotoxin testing), standardized procedures and centralized quality control. Conclusions Complex multicenter cell therapy and regenerative medicine protocols can, where necessary, successfully utilize local processing facilities once an effective infrastructure is in place to provide training, and quality control. PMID:20524773
Maughan, R
2012-06-01
The potential dose distribution advantages associated with proton therapy, and particularly with pencil beam scanning (PBS) techniques, have lead to considerable interest in this modality in recent years. However, the large capital expenditure necessary for such a project requires careful financial consideration and business planning. The complexity of the beam delivery systems impacts the capital expenditure and the PBS only systems presently being advocated can reduce these costs. Also several manufacturers are considering "one-room" facilities as less expensive alternatives to multi-room facilities. This presentation includes a brief introduction to beam delivery options (passive scattering, uniform and modulated scanning) and some of the new technologies proposed for providing less expensive proton therapy systems. Based on current experience, data on proton therapy center start-up costs, running costs and the financial challenges associated with making this highly conformal therapy more widely available will be discussed. Issues associated with proton therapy implementation that are key to project success include strong project management, vendor cooperation and collaboration, staff recruitment and training. Time management during facility start up is a major concern, particularly in multi-room systems, where time must be shared between continuing vendor system validation, verification and acceptance testing, and user commissioning and patient treatments. The challenges associated with facility operation during this period and beyond are discussed, focusing on how standardization of process, downtime and smart scheduling can influence operational efficiency. 1. To understand the available choices for proton therapy facilities, the different beam delivery systems and the financial implications associated with these choices. 2. To understand the key elements necessary for successfully implementing a proton therapy program. 3. To understand the challenges associated with on-going facility management to achieve an efficient fully operational system. © 2012 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osmanlioglu, Ahmet Erdal
Pre-treatment of radioactive waste is the first step in waste management program that occurs after waste generation from various applications in Turkey. Pre-treatment and characterization practices are carried out in Radioactive Waste Management Unit (RWMU) at Cekmece Nuclear Research and Training Center (CNRTC) in Istanbul. This facility has been assigned to take all low-level radioactive wastes generated by nuclear applications in Turkey. The wastes are generated from research and nuclear applications mainly in medicine, biology, agriculture, quality control in metal processing and construction industries. These wastes are classified as low- level radioactive wastes. Pre-treatment practices cover several steps. In thismore » paper, main steps of pre-treatment and characterization are presented. Basically these are; collection, segregation, chemical adjustment, size reduction and decontamination operations. (author)« less
ERIC Educational Resources Information Center
Potthoff, Joy K.
1991-01-01
Examined young adult male patient (n=18) satisfaction with interior environments of three different in-patient drug and alcohol rehabilitation facilities: renovated Elk's Club; hospital wing; and facility built for drug and alcohol treatment. Findings indicated satisfaction declined over four-week treatment period; familiar objects were missed;…
Dedicated nuclear facilities for electrolytic hydrogen production
NASA Technical Reports Server (NTRS)
Foh, S. E.; Escher, W. J. D.; Donakowski, T. D.
1979-01-01
An advanced technology, fully dedicated nuclear-electrolytic hydrogen production facility is presented. This plant will produce hydrogen and oxygen only and no electrical power will be generated for off-plant use. The conceptual design was based on hydrogen production to fill a pipeline at 1000 psi and a 3000 MW nuclear base, and the base-line facility nuclear-to-shaftpower and shaftpower-to-electricity subsystems, the water treatment subsystem, electricity-to-hydrogen subsystem, hydrogen compression, efficiency, and hydrogen production cost are discussed. The final conceptual design integrates a 3000 MWth high-temperature gas-cooled reactor operating at 980 C helium reactor-out temperature, direct dc electricity generation via acyclic generators, and high-current density, high-pressure electrolyzers based on the solid polymer electrolyte approach. All subsystems are close-coupled and optimally interfaced and pipeline hydrogen is produced at 1000 psi. Hydrogen costs were about half of the conventional nuclear electrolysis process.
Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.
Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo
2008-01-01
Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.
77 FR 823 - Guidance for Fuel Cycle Facility Change Processes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-06
... NUCLEAR REGULATORY COMMISSION [NRC-2009-0262] Guidance for Fuel Cycle Facility Change Processes... Fuel Cycle Facility Change Processes.'' This regulatory guide describes the types of changes for which fuel cycle facility licensees should seek prior approval from the NRC and discusses how licensees can...
This report presents the opportunities for combined heat and power (CHP) applications in the municipal wastewater treatment sector, and it documents the experiences of the wastewater treatment facility (WWTF) operators who have employed CHP.
NASA Astrophysics Data System (ADS)
Yver-Kwok, C. E.; Müller, D.; Caldow, C.; Lebègue, B.; Mønster, J. G.; Rella, C. W.; Scheutz, C.; Schmidt, M.; Ramonet, M.; Warneke, T.; Broquet, G.; Ciais, P.
2015-03-01
This study presents two methods for estimating methane emissions from a waste water treatment plant (WWTP) along with results from a measurement campaign at a WWTP in Valence, France. These methods, chamber measurements and tracer release, rely on Fourier Transform Infrared (FTIR) spectroscopy and Cavity Ring Down Spectroscopy (CRDS) instruments. We show that the tracer release method is suitable to quantify facility- and some process-scale emissions, while the chamber measurements, provide insight into individual process emissions. Uncertainties for the two methods are described and discussed. Applying the methods to CH4 emissions of the WWTP, we confirm that the open basins are not a major source of CH4 on the WWTP (about 10% of the total emissions), but that the pretreatment and sludge treatment are the main emitters. Overall, the waste water treatment plant represents a small part (about 1.5%) of the methane emissions of the city of Valence and its surroundings, which is lower than the national inventories.
NASA Astrophysics Data System (ADS)
Smith, Dana; Williams, Fred; Moffatt, Scott
Alcoa's Point Comfort, Texas industrial facility is a combination of a bauxite refining plant utilizing the Bayer process and an aluminum fluoride production plant. Due to the location's use of dry stack technology for bauxite residue disposal, the pond surface areas for evaporation are minimal compared to the rainfall catchment areas. This results in the periodic need to reduce accumulated volumes of storm water at the Residue Disposal Area (RDA).
Wen, Hefei; Cummings, Janet R.; Hockenberry, Jason M.; Gaydos, Laura M.; Druss, Benjamin G.
2014-01-01
Context The passage of the 2008 Mental Health Parity and Addiction Equity Act (MHPAEA) and the 2010 Affordable Care Act (ACA) incorporated parity for substance use disorder (SUD) into federal legislation. Yet prior research provides us with scant evidence as to whether federal parity legislation will hold the potential for improving access to SUD treatment. Objective This study examined the effect of state-level SUD parity laws on state-aggregate SUD treatment rates from 2000 to 2008, to shed light on the impact of the recent federal-level SUD parity legislation. Design A quasi-experimental study design using a two-way (state and year) fixed-effect method Setting and Participants All known specialty SUD treatment facilities in the United States Interventions State-level SUD parity laws between 2000 and 2008 Main Outcome Measures State-aggregate SUD treatment rates in: (1) all specialty SUD treatment facilities, and (2) specialty SUD treatment facilities accepting private insurance Results The implementation of any SUD parity law increased the treatment rate by 9 percent (p<0.01) in all specialty SUD treatment facilities and by 15 percent (p<0.05) in facilities accepting private insurance. Full parity and parity-if-offered (i.e., parity only if SUD coverage is offered) increased SUD treatment rate by 13 percent (p<0.05) and 8 percent (p<0.05) in all facilities, and by 21 percent (p<0.05) and 10 percent (p<0.05) in those accepting private insurance. Conclusions We found a positive effect of the implementation of state SUD parity legislation on access to specialty SUD treatment. Furthermore, the positive association was more pronounced in states with more comprehensive parity laws. Our findings suggest that federal parity legislation holds the potential to improve access to SUD treatment. PMID:24154931
Air modelling as an alternative to sampling for low-level radioactive airborne releases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgenstern, M.Y.; Hueske, K.
1995-05-01
This paper describes our efforts to assess the effect of airborne releases at one DOE laboratory using air modelling based on historical data. Among the facilities affected by these developments is Los Alamos National Laboratory (LANL) in New Mexico. RCRA, as amended by the Hazardous and Solid Waste Amendments (HSWA) in 1984, requires all facilities which involve the treatment, storage, and disposal of hazardous waste obtain a RCRA/HSWA waste facility permit. LANL complied with CEARP by initiating a process of identifying potential release sites associated with LANL operations prior to filing a RCRA/HSWA permit application. In the process of preparingmore » the RCRA/HSWA waste facility permit application to the U.S. Environmental Protection Agency (EPA), a total of 603 Solid Waste Management Units (SWMUs) were identified as part of the requirements of the HSWA Module VIH permit requirements. The HSWA Module VIII permit requires LANL to determine whether there have been any releases of hazardous waste or hazardous constituents from SWMUs at the facility dating from the 1940`s by performing a RCRA Facility Investigation to address known or suspected releases from specified SWMUs to affected media (i.e. soil, groundwater, surface water, and air). Among the most troublesome of the potential releases sites are those associated with airborne radioactive releases. In order to assess health risks associated with radioactive contaminants in a manner consistent with exposure standards currently in place, the DOE and LANL have established Screening Action Levels (SALs) for radioactive soil contamination. The SALs for each radionuclide in soil are derived from calculations based on a residential scenario in which individuals are exposed to contaminated soil via inhalation and ingestion as well as external exposure to gamma emitters in the soil. The applicable SALs are shown.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mike Lewis
2013-02-01
This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2011, through October 31, 2012. The report contains the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2012 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCabe, Daniel J.; Wilmarth, William R.; Nash, Charles A.
2014-01-07
The Waste Treatment and Immobilization Plant (WTP) process flow was designed to pre-treat feed from the Hanford tank farms, separate it into a High Level Waste (HLW) and Low Activity Waste (LAW) fraction and vitrify each fraction in separate facilities. Vitrification of the waste generates an aqueous condensate stream from the off-gas processes. This stream originates from two off-gas treatment unit operations, the Submerged Bed Scrubber (SBS) and the Wet Electrospray Precipitator (WESP). Currently, the baseline plan for disposition of the stream from the LAW melter is to recycle it to the Pretreatment facility where it gets evaporated and processedmore » into the LAW melter again. If the Pretreatment facility is not available, the baseline disposition pathway is not viable. Additionally, some components in the stream are volatile at melter temperatures, thereby accumulating to high concentrations in the scrubbed stream. It would be highly beneficial to divert this stream to an alternate disposition path to alleviate the close-coupled operation of the LAW vitrification and Pretreatment facilities, and to improve long-term throughput and efficiency of the WTP system. In order to determine an alternate disposition path for the LAW SBS/WESP Recycle stream, a range of options are being studied. A simulant of the LAW Off-Gas Condensate was developed, based on the projected composition of this stream, and comparison with pilot-scale testing. The primary radionuclide that vaporizes and accumulates in the stream is Tc-99, but small amounts of several other radionuclides are also projected to be present in this stream. The processes being investigated for managing this stream includes evaporation and radionuclide removal via precipitation and adsorption. During evaporation, it is of interest to investigate the formation of insoluble solids to avoid scaling and plugging of equipment. Key parameters for radionuclide removal include identifying effective precipitation or ion adsorption chemicals, solid-liquid separation methods, and achievable decontamination factors. Results of the radionuclide removal testing indicate that the radionuclides, including Tc-99, can be removed with inorganic sorbents and precipitating agents. Evaporation test results indicate that the simulant can be evaporated to fairly high concentration prior to formation of appreciable solids, but corrosion has not yet been examined.« less
Spacelab Data Processing Facility
NASA Technical Reports Server (NTRS)
1983-01-01
The capabilities of the Spacelab Data Processing Facility (SPDPF) are highlighted. The capturing, quality monitoring, processing, accounting, and forwarding of vital Spacelab data to various user facilities around the world are described.
Racial/ethnic differences in access to substance abuse treatment.
Lo, Celia C; Cheng, Tyrone C
2011-05-01
A secondary dataset, Collaborative Psychiatric Epidemiology Surveys (CPES), 2001-2003, was employed to examine racial/ethnic differences in access to specialty and non-specialty substance abuse treatment (compared with no access to treatment). The study found that non-Hispanic White Americans were (1) likelier than members of all racial/ethnic minority groups (other than Hispanics) to address substance abuse by accessing care through specialty addiction-treatment facilities, and were (2) also less likely to access substance abuse care through non-specialty facilities. Because non-specialty facilities may have staffs whose professional training does not target treating chronic, bio-psycho-social illness such as substance abuse, our results imply that treatment facilities deemed non-specialty may need to enhance staff training, in order to ensure individuals are properly screened for substance use conditions and are referred for or provided with effective counseling and medications as appropriate.
Cohn, Amy; Elmasry, Hoda; Niaura, Ray
2017-06-01
Cigarette smoking is common among patients in substance abuse treatment. Tobacco control programs have advocated for integrated tobacco dependence treatment into behavioral healthcare, including within substance abuse treatment facilities (SATFs) to reduce the public health burden of tobacco use. This study used data from seven waves (2006 to 2012) of the National Survey of Substance Abuse Treatment Services (n=94,145) to examine state and annual changes in the provision of smoking cessation services within US SATFs and whether changes over time could be explained by facility-level (private vs public ownership, receipt of earmarks, facility admissions, acceptance of government insurance) and state-level factors (cigarette tax per pack, smoke free policies, and percent of CDC recommended tobacco prevention spending). Results showed that the prevalence of SATFs offering smoking cessation services increased over time, from 13% to 65%. The amount of tax per cigarette pack, accepting government insurance, government (vs private) ownership, facility admissions, and CDC recommended tobacco prevention spending (per state) were the strongest correlates of the provision of smoking cessation programs in SATFs. Facilities that received earmarks were less likely to provide cessation services. Adult smoking prevalence and state-level smoke free policies were not significant correlates of the provision of smoking cessation services over time. Policies aimed at increasing the distribution of tax revenues to cessation services in SATFs may offset tobacco-related burden among those with substance abuse problems. Copyright © 2017. Published by Elsevier Inc.
POST-OPERATIONAL TREATMENT OF RESIDUAL NA COOLLANT IN EBR-2 USING CARBONATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, S.; Knight, C.
2011-03-08
At the end of 2002, the Experimental Breeder Reactor Two (EBR-II) facility became a U.S. Resource Conservation and Recovery Act (RCRA) permitted site, and the RCRA permit1 compelled further treatment of the residual sodium in order to convert it into a less reactive chemical form and remove the by-products from the facility, so that a state of RCRA 'closure' for the facility may be achieved (42 U.S.C. 6901-6992k, 2002). In response to this regulatory driver, and in recognition of project budgetary and safety constraints, it was decided to treat the residual sodium in the EBR-II primary and secondary sodium systemsmore » using a process known as 'carbonation.' In early EBR-II post-operation documentation, this process is also called 'passivation.' In the carbonation process (Sherman and Henslee, 2005), the system containing residual sodium is flushed with humidified carbon dioxide (CO{sub 2}). The water vapor in the flush gas reacts with residual sodium to form sodium hydroxide (NaOH), and the CO{sub 2} in the flush gas reacts with the newly formed NaOH to make sodium bicarbonate (NaHCO{sub 3}). Hydrogen gas (H{sub 2}) is produced as a by-product. The chemical reactions occur at the exposed surface of the residual sodium. The NaHCO{sub 3} layer that forms is porous, and humidified carbon dioxide can penetrate the NaHCO{sub 3} layer to continue reacting residual sodium underneath. The rate of reaction is controlled by the thickness of the NaHCO{sub 3} surface layer, the moisture input rate, and the residual sodium exposed surface area. At the end of carbonation, approximately 780 liters of residual sodium in the EBR-II primary tank ({approx}70% of original inventory), and just under 190 liters of residual sodium in the EBR-II secondary sodium system ({approx}50% of original inventory), were converted into NaHCO{sub 3}. No bare surfaces of residual sodium remained after treatment, and all remaining residual sodium deposits are covered by a layer of NaHCO{sub 3}. From a safety standpoint, the inventory of residual sodium in these systems was greatly reduced by using the carbonation process. From a regulatory standpoint, the process was not able to achieve deactivation of all residual sodium, and other more aggressive measures will be needed if the remaining residual sodium must also be deactivated to meet the requirements of the existing environmental permit. This chapter provides a project history and technical summary of the carbonation of EBR-II residual sodium. Options for future treatment are also discussed.« less
Yu, Shuyan; Liu, Jincheng; Zhu, Wenyu; Hu, Zhong-Ting; Lim, Teik-Thye; Yan, Xiaoli
2015-01-01
Carboxylic acid functionalized graphene oxide-copper (II) sulfide nanoparticle composite (GO-COOH-CuS) was prepared from carboxylated graphene oxide and copper precursor in dimethyl sulfoxide (DMSO) by a facile synthesis process at room temperature. The high-effective combination, the interaction between GO-COOH sheets and CuS nanoparticles, and the enhanced visible light absorption were confirmed by transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), X-ray powder diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), thermo gravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectra (DRS) and Photoluminescence (PL) spectra. The as-synthesized GO-COOH-CuS nanocomposite exhibited excellent photocatalytic degradation performance of phenol and rhodamine B, high antibacterial activity toward E. coli and B. subtilis, and good recovery and reusability. The influence of CuS content, the synergistic reaction between CuS and GO-COOH, and the charge-transfer mechanism were systematically investigated. The facile and low-energy synthesis process combined with the excellent degradation and antibacterial performance signify that the GO-COOH-CuS has a great potential for water treatment application. PMID:26553709
Srinivasan, Rangesh; Sorial, George A
2011-01-01
Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water and are mainly caused by the presence of two semi-volatile compounds--2-methyl isoborneol (MIB) and geosmin. A review of these two taste and odor causing compounds in drinking water is presented. The sources for the formation of these compounds in water are discussed along with the health and regulatory implications. The recent developments in the analysis of MIB/geosmin in water which have allowed for rapid measurements in the nanogram per liter concentrations are also discussed. This review focuses on the relevant treatment alternatives, that are described in detail with emphasis on their respective advantages and problems associated with their implementation in a full-scale facility. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for removal of MIB/geosmin. Studies have shown powdered activated carbon, ozonation and biofiltration to be effective in treatment of these two compounds. Although some of these technologies are more effective and show more promise than the others, much work remains to be done to optimize these technologies so that they can be retrofitted or installed with minimal impact on the overall operation and effectiveness of the treatment system.
An evaluation of substance misuse treatment providers used by an employee assistance program.
Miller, N A
1992-05-01
Structural measures of access, continuity, and quality of substance misuse treatment services were compared in 30 fee-for-service (FFS) facilities and nine health maintenance organizations (HMOs). Probit models related effects of the provider system (FFS or HMO) and the system's structural characteristics to 243 employees' access to and outcomes from treatment. Access was decreased in Independent Practice Association (IPA)/network HMOs and in all facilities which did not employ an addictionologist or provide coordinated treatment services. When bivariate correlations were examined, both use of copayments and imposing limits to the levels of treatment covered were negatively related to access, while a facility's provision of ongoing professional development was positively associated with access. These correlations did not remain significant in the multivariate probits. Receiving treatment in a staff model HMO and facing limits to the levels of treatment covered were negatively associated with attaining sufficient progress, while receiving treatment in a facility which provided ongoing professional development was positively related to progress: these effects did not remain significant in multivariate analyses. Implications for employee assistance program (EAP) staff in their role as case managers and for EAP staff and employers in their shared role as purchasers of treatment are discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-21
.... APHIS-2009-0100] RIN 0579-AD35 Irradiation Treatment; Location of Facilities in the Southern United... things, allow for irradiation treatment of mangoes from India upon arrival in the mainland United States... 20, 2012, we amended the regulations in Sec. 319.56-46 to allow for irradiation treatment of mangoes...
Evaluation of components of residential treatment by Medicaid ICF-MR surveys: a validity assessment.
Reid, D H; Parsons, M B; Green, C W; Schepis, M M
1991-01-01
We evaluated the proficiency of the federal Medicaid program's survey process for evaluating intermediate care facilities for the mentally retarded. In Study 1, an observational analysis of active treatment during leisure times in living units suggested that these surveys did not discriminate between certified and noncertified units. In Study 2, a reactivity analysis of a survey indicated that direct-care staff performed differently during the survey by increasing interactions with clients and decreasing nonwork behavior. Similarly, results of Study 3 showed increases in client access to leisure materials during a survey. In Study 4, questionnaire results indicated considerable variability among service providers' opinions on the consistency, accuracy, and objectivity with which survey teams determine agency standard compliance. Results are discussed regarding effects of the questionable proficiency of survey processes and the potential utility of behavioral assessment methodologies to improve such processes. PMID:1909696
78 FR 77009 - Section 306D Water Systems for Rural and Native Villages in Alaska
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... ``establish a program designed to provide safe water and hygienic disposal facilities in the State of Alaska... treatment facilities and wastewater treatment and collection facilities. Drinking water was hauled from... CFR Part 1784 RIN 0572-AC28 Section 306D Water Systems for Rural and Native Villages in Alaska AGENCY...
Influence of processing factors over concrete strength.
NASA Astrophysics Data System (ADS)
Kara, K. A.; Dolzhenko, A. V.; Zharikov, I. S.
2018-03-01
Construction of facilities of cast in-situ reinforced concrete poses additional requirements to quality of material, peculiarities of the construction process may sometimes lead to appearance of lamination planes and inhomogeneity of concrete, which reduce strength of the material and structure as a whole. Technology compliance while working with cast in-situ concrete has a significant impact onto the concrete strength. Such process factors as concrete curing, vibration and compaction of the concrete mixture, temperature treatment, etc., when they are countered or inadequately followed lead to a significant reduction in concrete strength. Here, the authors experimentally quantitatively determine the loss of strength in in-situ cast concrete structures due to inadequate following of process requirements, in comparison with full compliance.
NASA Astrophysics Data System (ADS)
Oh, Harim; Lee, Jeeyoung; Lee, Myeongkyu
2018-01-01
We comparatively study the morphological evolutions of silver nanowires under nanosecond-pulsed laser irradiation and thermal treatment in ambient air. While single-crystalline, pure Ag nanospheres could be produced by laser-driven Rayleigh instability, the particles produced by heat treatment were subject to oxidation and exhibited polyhedron shapes. The different results are attributed to the significantly different time scales of the two processes. In this article, we also show that bimetallic Ag-Au nanospheres can be synthesized by irradiating Ag nanowires coated with a thin Au film using a pulsed laser beam. This may provide a facile route to tune the plasmonic behavior of metal nanoparticles.
Radioactive waste management treatments: A selection for the Italian scenario
DOE Office of Scientific and Technical Information (OSTI.GOV)
Locatelli, G.; Mancini, M.; Sardini, M.
2012-07-01
The increased attention for radioactive waste management is one of the most peculiar aspects of the nuclear sector considering both reactors and not power sources. The aim of this paper is to present the state-of-art of treatments for radioactive waste management all over the world in order to derive guidelines for the radioactive waste management in the Italian scenario. Starting with an overview on the international situation, it analyses the different sources, amounts, treatments, social and economic impacts looking at countries with different industrial backgrounds, energetic policies, geography and population. It lists all these treatments and selects the most reasonablemore » according to technical, economic and social criteria. In particular, a double scenario is discussed (to be considered in case of few quantities of nuclear waste): the use of regional, centralized, off site processing facilities, which accept waste from many nuclear plants, and the use of mobile systems, which can be transported among multiple nuclear sites for processing campaigns. At the end the treatments suitable for the Italian scenario are presented providing simplified work-flows and guidelines. (authors)« less
Financing CHP Projects at Wastewater Treatment Facilities with Clean Water State Revolving Funds
This factsheet provides information about CHP at wastewater treatment facilities, including applications, financial challenges, and financial opportunities, such as the Clean Water State Revolving Fund.
40 CFR 35.2127 - Federal facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... STATE AND LOCAL ASSISTANCE Grants for Construction of Treatment Works § 35.2127 Federal facilities... day or 5 percent of the design flow of the complete waste treatment system, whichever is less...
Ivahnenko, Tamara I.
2017-12-07
Changes in municipal and industrial point-source discharges over time have been an important factor affecting nutrient trends in many of the Nation’s streams and rivers. This report documents how three U.S. Environmental Protection Agency (EPA) national datasets—the Permit Compliance System, the Integrated Compliance Information System, and the Clean Watersheds Needs Survey—were evaluated for use in the U.S. Geological Survey National Water-Quality Assessment project to assess the causes of nutrient trends. This report also describes how a database of total nitrogen load and total phosphorous load was generated for select wastewater treatment facilities in the United States based on information reported in the EPA Clean Watersheds Needs Survey. Nutrient loads were calculated for the years 1978, 1980, 1982, 1984, 1986, 1988, 1990, 1992, 1996, 2000, 2004, 2008, and 2012 based on average nitrogen and phosphorous concentrations for reported treatment levels and on annual reported flow values.The EPA Permit Compliance System (PCS) and Integrated Compliance Information System (ICIS), which monitor point-source facility discharges, together are the Nation’s most spatially comprehensive dataset for nutrients released to surface waters. However, datasets for many individual facilities are incomplete, the PCS/ICIS historical data date back only to 1989, and historical data are available for only a limited number of facilities. Additionally, inconsistencies in facility reporting make it difficult to track or identify changes in nutrient discharges over time. Previous efforts made by the U.S. Geological Survey to “fill in” gaps in the PCS/ICIS data were based on statistical methods—missing data were filled in through the use of a statistical model based on the Standard Industrial Classification code, size, and flow class of the facility and on seasonal nutrient discharges of similar facilities. This approach was used to estimate point-source loads for a single point in time; it was not evaluated for use in generating a consistent data series over time.Another national EPA dataset that is available is the Clean Watersheds Needs Survey (CWNS), conducted every 4 years beginning 1973. The CWNS is an assessment of the capital needs of wastewater facilities to meet the water-quality goals set in the Clean Water Act. Data collected about these facilities include location and contact information for the facilities; population served; flow and treatment level of the facility; estimated capital needs to upgrade, repair, or improve facilities for water quality; and nonpoint-source best management practices.Total nitrogen and total phosphorous load calculations for each of the CWNS years were based on treatment level information and average annual outflow (in million gallons per day) from each of the facilities that had reported it. Treatment levels categories (such as Primary, Secondary, or Advanced) were substituted with average total nitrogen and total phosphorous concentrations for each treatment level based on those reported in literature. The CWNS dataset, like the PCS/ICIS dataset, has years where facilities did not report either a treatment level or an annual average outflow, or both. To fill in the data gaps, simple linear assumptions were made based on each facility’s responses to the survey in years bracketing the data gap or immediately before or after the data gap if open ended. Treatment level and flow data unique to each facility were used to complete the CWNS dataset for that facility.
Implementation research to improve quality of maternal and newborn health care, Malawi
Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-01-01
Abstract Objective To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. Methods We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities’ essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. Findings We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants’ adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Conclusion Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care. PMID:28670014
Wandwalo, Eliud; Robberstad, Bjarne; Morkve, Odd
2005-01-01
Background Identifying new approaches to tuberculosis treatment that are effective and put less demand to meagre health resources is important. One such approach is community based direct observed treatment (DOT). The purpose of the study was to determine the cost and cost effectiveness of health facility and community based directly observed treatment of tuberculosis in an urban setting in Tanzania. Methods Two alternative strategies were compared: health facility based directly observed treatment by health personnel and community based directly observed treatment by treatment supervisors. Costs were analysed from the perspective of health services, patients and community in the year 2002 in US $ using standard methods. Treatment outcomes were obtained from a randomised-controlled trial which was conducted alongside the cost study. Smear positive, smear negative and extra-pulmonary TB patients were included. Cost-effectiveness was calculated as the cost per patient successfully treated. Results The total cost of treating a patient with conventional health facility based DOT and community based DOT were $ 145 and $ 94 respectively. Community based DOT reduced cost by 35%. Cost fell by 27% for health services and 72% for patients. When smear positive and smear negative patients were considered separately, community DOT was associated with 45% and 19% reduction of the costs respectively. Patients used about $ 43 to follow their medication to health facility which is equivalent to their monthly income. Indirect costs were as important as direct costs, contributing to about 49% of the total patient's cost. The main reason for reduced cost was fewer number of visits to the TB clinic. Community based DOT was more cost-effective at $ 128 per patient successfully treated compared to $ 203 for a patient successfully treated with health facility based DOT. Conclusion Community based DOT presents an economically attractive option to complement health facility based DOT. This is particularly important in settings where TB clinics are working beyond capacity under limited resources. PMID:16018806
Code of Federal Regulations, 2010 CFR
2010-04-01
... the pre-filing review of any pipeline or other natural gas facilities, including facilities not... from the subject LNG terminal facilities to the existing natural gas pipeline infrastructure. (b) Other... and review process for LNG terminal facilities and other natural gas facilities prior to filing of...
Industrial uses of radiation processing in Belgium
NASA Astrophysics Data System (ADS)
Lacroix, J. P.
Since 1979, the Irradiation Department of IRE, in conjunction with universities and the industrial sector, has set up an extensive programme of research, development and promotion of the radiation process applied to cross-linking and polymerization of plastics, to waste treatment and to food preservation. Starting from scratch, it is thanks to our research in this last-mentioned field that we have been able to develop and to increase the application of the irradiation process within the food industry. At present, two irradiation facilities of a total design capacity of 2.5 10 6 Ci irradiate 24 hours per day mostly for the agro-industry.
Ellerbe, Laura S; Manfredi, Luisa; Gupta, Shalini; Phelps, Tyler E; Bowe, Thomas R; Rubinsky, Anna D; Burden, Jennifer L; Harris, Alex H S
2017-04-04
In the U.S. Department of Veterans Affairs (VA), residential treatment programs are an important part of the continuum of care for patients with a substance use disorder (SUD). However, a limited number of program-specific measures to identify quality gaps in SUD residential programs exist. This study aimed to: (1) Develop metrics for two pre-admission processes: Wait Time and Engagement While Waiting, and (2) Interview program management and staff about program structures and processes that may contribute to performance on these metrics. The first aim sought to supplement the VA's existing facility-level performance metrics with SUD program-level metrics in order to identify high-value targets for quality improvement. The second aim recognized that not all key processes are reflected in the administrative data, and even when they are, new insight may be gained from viewing these data in the context of day-to-day clinical practice. VA administrative data from fiscal year 2012 were used to calculate pre-admission metrics for 97 programs (63 SUD Residential Rehabilitation Treatment Programs (SUD RRTPs); 34 Mental Health Residential Rehabilitation Treatment Programs (MH RRTPs) with a SUD track). Interviews were then conducted with management and front-line staff to learn what factors may have contributed to high or low performance, relative to the national average for their program type. We hypothesized that speaking directly to residential program staff may reveal innovative practices, areas for improvement, and factors that may explain system-wide variability in performance. Average wait time for admission was 16 days (SUD RRTPs: 17 days; MH RRTPs with a SUD track: 11 days), with 60% of Veterans waiting longer than 7 days. For these Veterans, engagement while waiting occurred in an average of 54% of the waiting weeks (range 3-100% across programs). Fifty-nine interviews representing 44 programs revealed factors perceived to potentially impact performance in these domains. Efficient screening processes, effective patient flow, and available beds were perceived to facilitate shorter wait times, while lack of beds, poor staffing levels, and lengths of stay of existing patients were thought to lengthen wait times. Accessible outpatient services, strong patient outreach, and strong encouragement of pre-admission outpatient treatment emerged as facilitators of engagement while waiting; poor staffing levels, socioeconomic barriers, and low patient motivation were viewed as barriers. Metrics for pre-admission processes can be helpful for monitoring residential SUD treatment programs. Interviewing program management and staff about drivers of performance metrics can play a complementary role by identifying innovative and other strong practices, as well as high-value targets for quality improvement. Key facilitators of high-performing facilities may offer programs with lower performance useful strategies to improve specific pre-admission processes.
Cost effective modular unit for cleaning oil and gas field waste water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zinberg, M.B.; Nenasheva, M.N.; Gafarov, N.A.
1996-12-31
Problems of environmental control involving conservation of water resources are vital for the development of giant oil and gas condensate fields near Caspian Sea (Russia) characterized by water shortages. One of the urgent tasks of oil production industry is to use all field waste water consisting of underground, processing and rain water. It was necessary to construct a new highly effective equipment which could be used in local waste water treatment. Now we have at our disposal a technology and equipment to meet the requirements to the treated water quality. Thus we have installed a modular unit of 100 m{supmore » 3}/a day capacity to clean waste water from oil products, suspended matter and other organic pollutants at Orenburg oil and gas condensate field, Russia. The unit provides with a full treatment of produced water and comprises a settling tank with adhesive facility, the number of sorption filters, Trofactor bioreactors and a disinfecting facility. The equipment is fitted into three boxes measuring 9 x 3.2 x 2.7 in each. The equipment is simple in design that enables to save money, time and space. Sorption filters, bioreactors as well as the Trofactor process are a part of know-how. While working on the unit construction we applied well known methods of settling and sorption. The process of mechanic cleaning is undergoing in the following succession: (1) the gravitational separation in a settling tank where the floated film oil products are constantly gathered and the sediment is periodically taken away, (2) the settled water treatment in sorption Filters of a special kind.« less
Fabrication of amorphous silica nanowires via oxygen plasma treatment of polymers on silicon
NASA Astrophysics Data System (ADS)
Chen, Zhuojie; She, Didi; Chen, Qinghua; Li, Yanmei; Wu, Wengang
2018-02-01
We demonstrate a facile non-catalytic method of fabricating silica nanowires at room temperature. Different polymers including photoresists, parylene C and polystyrene are patterned into pedestals on the silicon substrates. The silica nanowires are obtained via the oxygen plasma treatment on those pedestals. Compared to traditional strategies of silica nanowire fabrication, this method is much simpler and low-cost. Through designing the proper initial patterns and plasma process parameters, the method can be used to fabricate various regiment nano-scale silica structure arrays in any laboratory with a regular oxygen-plasma-based cleaner or reactive-ion-etching equipment.
242-A Evaporator quality assurance plan. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basra, T.S.
1995-05-04
The purpose of this quality assurance project plan (Plan) is to provide requirements for activities pertaining to sampling, shipping, and analyses associated with candidate feed tank samples for the 242-A Evaporator project. The purpose of the 242-A Evaporator project is to reduce the volume of aqueous waste in the Double Shell Tank (DST) System and will result in considerable savings to the disposal of mixed waste. The 242-A Evaporator feed stream originates from DSTs identified as candidate feed tanks. The 242-A Evaporator reduces the volume of aqueous waste contained in DSTs by boiling off water and sending the condensate (calledmore » process condensate) to the Liquid Effluent Retention Facility (LEPF) storage basin where it is stored prior to treatment in the Effluent Treatment Facility (ETF). The objective of this quality assurance project plan is to provide the planning, implementation, and assessment of sample collection and analysis, data issuance, and validation activities for the candidate feed tanks.« less