Automated detection of microcalcification clusters in mammograms
NASA Astrophysics Data System (ADS)
Karale, Vikrant A.; Mukhopadhyay, Sudipta; Singh, Tulika; Khandelwal, Niranjan; Sadhu, Anup
2017-03-01
Mammography is the most efficient modality for detection of breast cancer at early stage. Microcalcifications are tiny bright spots in mammograms and can often get missed by the radiologist during diagnosis. The presence of microcalcification clusters in mammograms can act as an early sign of breast cancer. This paper presents a completely automated computer-aided detection (CAD) system for detection of microcalcification clusters in mammograms. Unsharp masking is used as a preprocessing step which enhances the contrast between microcalcifications and the background. The preprocessed image is thresholded and various shape and intensity based features are extracted. Support vector machine (SVM) classifier is used to reduce the false positives while preserving the true microcalcification clusters. The proposed technique is applied on two different databases i.e DDSM and private database. The proposed technique shows good sensitivity with moderate false positives (FPs) per image on both databases.
NASA Astrophysics Data System (ADS)
Sahiner, Berkman; Gurcan, Metin N.; Chan, Heang-Ping; Hadjiiski, Lubomir M.; Petrick, Nicholas; Helvie, Mark A.
2002-05-01
We are developing new techniques to improve the accuracy of computerized microcalcification detection by using the joint two-view information on craniocaudal (CC) and mediolateral-oblique (MLO) views. After cluster candidates were detected using a single-view detection technique, candidates on CC and MLO views were paired using their radial distances from the nipple. Object pairs were classified with a joint two-view classifier that used the similarity of objects in a pair. Each cluster candidate was also classified as a true microcalcification cluster or a false-positive (FP) using its single-view features. The outputs of these two classifiers were fused. A data set of 38 pairs of mammograms from our database was used to train the new detection technique. The independent test set consisted of 77 pairs of mammograms from the University of South Florida public database. At a per-film sensitivity of 70%, the FP rates were 0.17 and 0.27 with the fusion and single-view detection methods, respectively. Our results indicate that correspondence of cluster candidates on two different views provides valuable additional information for distinguishing false from true microcalcification clusters.
NASA Astrophysics Data System (ADS)
Park, Sang Cheol; Zheng, Bin; Wang, Xiao-Hui; Gur, David
2008-03-01
Digital breast tomosynthesis (DBT) has emerged as a promising imaging modality for screening mammography. However, visually detecting micro-calcification clusters depicted on DBT images is a difficult task. Computer-aided detection (CAD) schemes for detecting micro-calcification clusters depicted on mammograms can achieve high performance and the use of CAD results can assist radiologists in detecting subtle micro-calcification clusters. In this study, we compared the performance of an available 2D based CAD scheme with one that includes a new grouping and scoring method when applied to both projection and reconstructed DBT images. We selected a dataset involving 96 DBT examinations acquired on 45 women. Each DBT image set included 11 low dose projection images and a varying number of reconstructed image slices ranging from 18 to 87. In this dataset 20 true-positive micro-calcification clusters were visually detected on the projection images and 40 were visually detected on the reconstructed images, respectively. We first applied the CAD scheme that was previously developed in our laboratory to the DBT dataset. We then tested a new grouping method that defines an independent cluster by grouping the same cluster detected on different projection or reconstructed images. We then compared four scoring methods to assess the CAD performance. The maximum sensitivity level observed for the different grouping and scoring methods were 70% and 88% for the projection and reconstructed images with a maximum false-positive rate of 4.0 and 15.9 per examination, respectively. This preliminary study demonstrates that (1) among the maximum, the minimum or the average CAD generated scores, using the maximum score of the grouped cluster regions achieved the highest performance level, (2) the histogram based scoring method is reasonably effective in reducing false-positive detections on the projection images but the overall CAD sensitivity is lower due to lower signal-to-noise ratio, and (3) CAD achieved higher sensitivity and higher false-positive rate (per examination) on the reconstructed images. We concluded that without changing the detection threshold or performing pre-filtering to possibly increase detection sensitivity, current CAD schemes developed and optimized for 2D mammograms perform relatively poorly and need to be re-optimized using DBT datasets and new grouping and scoring methods need to be incorporated into the schemes if these are to be used on the DBT examinations.
Wang, Huiya; Feng, Jun; Wang, Hongyu
2017-07-20
Detection of clustered microcalcification (MC) from mammograms plays essential roles in computer-aided diagnosis for early stage breast cancer. To tackle problems associated with the diversity of data structures of MC lesions and the variability of normal breast tissues, multi-pattern sample space learning is required. In this paper, a novel grouped fuzzy Support Vector Machine (SVM) algorithm with sample space partition based on Expectation-Maximization (EM) (called G-FSVM) is proposed for clustered MC detection. The diversified pattern of training data is partitioned into several groups based on EM algorithm. Then a series of fuzzy SVM are integrated for classification with each group of samples from the MC lesions and normal breast tissues. From DDSM database, a total of 1,064 suspicious regions are selected from 239 mammography, and the measurement of Accuracy, True Positive Rate (TPR), False Positive Rate (FPR) and EVL = TPR* 1-FPR are 0.82, 0.78, 0.14 and 0.72, respectively. The proposed method incorporates the merits of fuzzy SVM and multi-pattern sample space learning, decomposing the MC detection problem into serial simple two-class classification. Experimental results from synthetic data and DDSM database demonstrate that our integrated classification framework reduces the false positive rate significantly while maintaining the true positive rate.
Three-dimensional reconstruction of clustered microcalcifications from two digitized mammograms
NASA Astrophysics Data System (ADS)
Stotzka, Rainer; Mueller, Tim O.; Epper, Wolfgang; Gemmeke, Hartmut
1998-06-01
X-ray mammography is one of the most significant diagnosis methods in early detection of breast cancer. Usually two X- ray images from different angles are taken from each mamma to make even overlapping structures visible. X-ray mammography has a very high spatial resolution and can show microcalcifications of 50 - 200 micron in size. Clusters of microcalcifications are one of the most important and often the only indicator for malignant tumors. These calcifications are in some cases extremely difficult to detect. Computer assisted diagnosis of digitized mammograms may improve detection and interpretation of microcalcifications and cause more reliable diagnostic findings. We build a low-cost mammography workstation to detect and classify clusters of microcalcifications and tissue densities automatically. New in this approach is the estimation of the 3D formation of segmented microcalcifications and its visualization which will put additional diagnostic information at the radiologists disposal. The real problem using only two or three projections for reconstruction is the big loss of volume information. Therefore the arrangement of a cluster is estimated using only the positions of segmented microcalcifications. The arrangement of microcalcifications is visualized to the physician by rotating.
Computer aided detection of clusters of microcalcifications on full field digital mammograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge Jun; Sahiner, Berkman; Hadjiiski, Lubomir M.
2006-08-15
We are developing a computer-aided detection (CAD) system to identify microcalcification clusters (MCCs) automatically on full field digital mammograms (FFDMs). The CAD system includes six stages: preprocessing; image enhancement; segmentation of microcalcification candidates; false positive (FP) reduction for individual microcalcifications; regional clustering; and FP reduction for clustered microcalcifications. At the stage of FP reduction for individual microcalcifications, a truncated sum-of-squares error function was used to improve the efficiency and robustness of the training of an artificial neural network in our CAD system for FFDMs. At the stage of FP reduction for clustered microcalcifications, morphological features and features derived from themore » artificial neural network outputs were extracted from each cluster. Stepwise linear discriminant analysis (LDA) was used to select the features. An LDA classifier was then used to differentiate clustered microcalcifications from FPs. A data set of 96 cases with 192 images was collected at the University of Michigan. This data set contained 96 MCCs, of which 28 clusters were proven by biopsy to be malignant and 68 were proven to be benign. The data set was separated into two independent data sets for training and testing of the CAD system in a cross-validation scheme. When one data set was used to train and validate the convolution neural network (CNN) in our CAD system, the other data set was used to evaluate the detection performance. With the use of a truncated error metric, the training of CNN could be accelerated and the classification performance was improved. The CNN in combination with an LDA classifier could substantially reduce FPs with a small tradeoff in sensitivity. By using the free-response receiver operating characteristic methodology, it was found that our CAD system can achieve a cluster-based sensitivity of 70, 80, and 90 % at 0.21, 0.61, and 1.49 FPs/image, respectively. For case-based performance evaluation, a sensitivity of 70, 80, and 90 % can be achieved at 0.07, 0.17, and 0.65 FPs/image, respectively. We also used a data set of 216 mammograms negative for clustered microcalcifications to further estimate the FP rate of our CAD system. The corresponding FP rates were 0.15, 0.31, and 0.86 FPs/image for cluster-based detection when negative mammograms were used for estimation of FP rates.« less
Hough transform for clustered microcalcifications detection in full-field digital mammograms
NASA Astrophysics Data System (ADS)
Fanizzi, A.; Basile, T. M. A.; Losurdo, L.; Amoroso, N.; Bellotti, R.; Bottigli, U.; Dentamaro, R.; Didonna, V.; Fausto, A.; Massafra, R.; Moschetta, M.; Tamborra, P.; Tangaro, S.; La Forgia, D.
2017-09-01
Many screening programs use mammography as principal diagnostic tool for detecting breast cancer at a very early stage. Despite the efficacy of the mammograms in highlighting breast diseases, the detection of some lesions is still doubtless for radiologists. In particular, the extremely minute and elongated salt-like particles of microcalcifications are sometimes no larger than 0.1 mm and represent approximately half of all cancer detected by means of mammograms. Hence the need for automatic tools able to support radiologists in their work. Here, we propose a computer assisted diagnostic tool to support radiologists in identifying microcalcifications in full (native) digital mammographic images. The proposed CAD system consists of a pre-processing step, that improves contrast and reduces noise by applying Sobel edge detection algorithm and Gaussian filter, followed by a microcalcification detection step performed by exploiting the circular Hough transform. The procedure performance was tested on 200 images coming from the Breast Cancer Digital Repository (BCDR), a publicly available database. The automatically detected clusters of microcalcifications were evaluated by skilled radiologists which asses the validity of the correctly identified regions of interest as well as the system error in case of missed clustered microcalcifications. The system performance was evaluated in terms of Sensitivity and False Positives per images (FPi) rate resulting comparable to the state-of-art approaches. The proposed model was able to accurately predict the microcalcification clusters obtaining performances (sensibility = 91.78% and FPi rate = 3.99) which favorably compare to other state-of-the-art approaches.
A fully automatic microcalcification detection approach based on deep convolution neural network
NASA Astrophysics Data System (ADS)
Cai, Guanxiong; Guo, Yanhui; Zhang, Yaqin; Qin, Genggeng; Zhou, Yuanpin; Lu, Yao
2018-02-01
Breast cancer is one of the most common cancers and has high morbidity and mortality worldwide, posing a serious threat to the health of human beings. The emergence of microcalcifications (MCs) is an important signal of early breast cancer. However, it is still challenging and time consuming for radiologists to identify some tiny and subtle individual MCs in mammograms. This study proposed a novel computer-aided MC detection algorithm on the full field digital mammograms (FFDMs) using deep convolution neural network (DCNN). Firstly, a MC candidate detection system was used to obtain potential MC candidates. Then a DCNN was trained using a novel adaptive learning strategy, neutrosophic reinforcement sample learning (NRSL) strategy to speed up the learning process. The trained DCNN served to recognize true MCs. After been classified by DCNN, a density-based regional clustering method was imposed to form MC clusters. The accuracy of the DCNN with our proposed NRSL strategy converges faster and goes higher than the traditional DCNN at same epochs, and the obtained an accuracy of 99.87% on training set, 95.12% on validation set, and 93.68% on testing set at epoch 40. For cluster-based MC cluster detection evaluation, a sensitivity of 90% was achieved at 0.13 false positives (FPs) per image. The obtained results demonstrate that the designed DCNN plays a significant role in the MC detection after being prior trained.
Jeong, Ji-Wook; Chae, Seung-Hoon; Chae, Eun Young; Kim, Hak Hee; Choi, Young-Wook; Lee, Sooyeul
2016-01-01
We propose computer-aided detection (CADe) algorithm for microcalcification (MC) clusters in reconstructed digital breast tomosynthesis (DBT) images. The algorithm consists of prescreening, MC detection, clustering, and false-positive (FP) reduction steps. The DBT images containing the MC-like objects were enhanced by a multiscale Hessian-based three-dimensional (3D) objectness response function and a connected-component segmentation method was applied to extract the cluster seed objects as potential clustering centers of MCs. Secondly, a signal-to-noise ratio (SNR) enhanced image was also generated to detect the individual MC candidates and prescreen the MC-like objects. Each cluster seed candidate was prescreened by counting neighboring individual MC candidates nearby the cluster seed object according to several microcalcification clustering criteria. As a second step, we introduced bounding boxes for the accepted seed candidate, clustered all the overlapping cubes, and examined. After the FP reduction step, the average number of FPs per case was estimated to be 2.47 per DBT volume with a sensitivity of 83.3%.
1997-09-01
employed to classify benign and malignant microcalcifications in the radiographs of pathological specimen that were digitized at a high resolution of...21 microns x 21 microns. The CNN achieved an Az value of 0.90 in classifying clusters of microcalcifications associated with benign and malignant processes
NASA Astrophysics Data System (ADS)
Harkness, E. F.; Lim, Y. Y.; Wilson, M. W.; Haq, R.; Zhou, J.; Tate, C.; Maxwell, A. J.; Astley, S. M.; Gilbert, F. J.
2015-03-01
Digital breast tomosynthesis (DBT) addresses limitations of 2-D projection imaging for detection of masses. Microcalcification clusters may be more difficult to appreciate in DBT as individual calcifications within clusters may appear on different slices. This research aims to evaluate the performance of ImageChecker 3D Calc CAD v1.0. Women were recruited as part of the TOMMY trial. From the trial, 169 were included in this study. The DBT images were processed with the computer aided detection (CAD) algorithm. Three consultant radiologists reviewed the images and recorded whether CAD prompts were on or off target. 79/80 (98.8%) malignant cases had a prompt on the area of microcalcification. In these cases, there were 1-15 marks (median 5) with the majority of false prompts (n=326/431) due to benign (68%) and vascular (24%) calcifications. Of 89 normal/benign cases, there were 1-13 prompts (median 3), 27 (30%) had no prompts and the majority of false prompts (n=238) were benign (77%) calcifications. CAD is effective in prompting malignant microcalcification clusters and may overcome the difficulty of detecting clusters in slice images. Although there was a high rate of false prompts, further advances in the software may improve specificity.
NASA Astrophysics Data System (ADS)
Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.
1986-06-01
We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted observer performance experiments to evaluate the detectability of micro-calcifications in three sets of mammograms: the original film images, unprocessed digitized images, and unsharp-masked images. Each set included the same 20 normal cases and 12 abnormal cases. A total of 5 board-certified radiologists and 4 senior radiology residents participated as observers. In the first experiment, the detectability of microcalcifications was measured for the original, unprocessed digitized, and unsharp-masked images. Each observer read all 96 films in one session with the cases arranged in a different random order. A maximum of 15 seconds was allowed to read each image. To facilitate receiver operating character-istic (ROC) analysis, each observer ranked his/her observation regarding the presence or absence of a cluster of 3 or more microcalcifications on a 5-point confidence rating scale (1=definitely no microcalcifications, 2=probably no microcalcifications; 3=microcalcifi-cations possibly present; 4=microcalcifications probably present; 5=microcalcifications definitely present). The observer identified the location of the suspected microcalci-fications when the confidence rating was 2 or greater. In the second experiment, we evaluated whether reading the unsharp-masked image and the unprocessed digitized image side by side for each case would reduce false-positive detection rates for microcalcifications and thus improve overall performance. The observer was again allowed a maximum of 15 seconds to read each pair of images and was instructed to use the unsharp-masked image for primary reading and the unprocessed digitized image for reference. The experimental setting and procedures were otherwise the same as those for the first experiment.
Segmentation for the enhancement of microcalcifications in digital mammograms.
Milosevic, Marina; Jankovic, Dragan; Peulic, Aleksandar
2014-01-01
Microcalcification clusters appear as groups of small, bright particles with arbitrary shapes on mammographic images. They are the earliest sign of breast carcinomas and their detection is the key for improving breast cancer prognosis. But due to the low contrast of microcalcifications and same properties as noise, it is difficult to detect microcalcification. This work is devoted to developing a system for the detection of microcalcification in digital mammograms. After removing noise from mammogram using the Discrete Wavelet Transformation (DWT), we first selected the region of interest (ROI) in order to demarcate the breast region on a mammogram. Segmenting region of interest represents one of the most important stages of mammogram processing procedure. The proposed segmentation method is based on a filtering using the Sobel filter. This process will identify the significant pixels, that belong to edges of microcalcifications. Microcalcifications were detected by increasing the contrast of the images obtained by applying Sobel operator. In order to confirm the effectiveness of this microcalcification segmentation method, the Support Vector Machine (SVM) and k-Nearest Neighborhood (k-NN) algorithm are employed for the classification task using cross-validation technique.
Clustering microcalcifications techniques in digital mammograms
NASA Astrophysics Data System (ADS)
Díaz, Claudia. C.; Bosco, Paolo; Cerello, Piergiorgio
2008-11-01
Breast cancer has become a serious public health problem around the world. However, this pathology can be treated if it is detected in early stages. This task is achieved by a radiologist, who should read a large amount of mammograms per day, either for a screening or diagnostic purpose in mammography. However human factors could affect the diagnosis. Computer Aided Detection is an automatic system, which can help to specialists in the detection of possible signs of malignancy in mammograms. Microcalcifications play an important role in early detection, so we focused on their study. The two mammographic features that indicate the microcalcifications could be probably malignant are small size and clustered distribution. We worked with density techniques for automatic clustering, and we applied them on a mammography CAD prototype developed at INFN-Turin, Italy. An improvement of performance is achieved analyzing images from a Perugia-Assisi Hospital, in Italy.
[Changes in mammographic features of breast cancer--comparison with previous films].
Matsunaga, T; Hagiwara, K; Kimura, K; Kusama, M
1992-11-25
Mammographic features of 87 breast cancer patients were studied in comparison with their previous survey films. Changes in the mammographic features included microcalicification (28 cases), tumor shadow (35 cases) and intratumorous microcalicifications (6 cases). Seven cases had several extremely faint calcifications on the previous films, and three of six cases with clustered and scattered microcalcifications that extended over an entire breast quadrant had increased in number, density and extent. Eight cases in which clustered microcalcifications had increased in number, density and extent suggested a relationship between the increase in the extent of microcalcifications and length of time between visits. In most cases with tumor shadow, a slight localized increase in mammary gland density, irregular margins and straightened trabeculae were overlooked because of breast density.
Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.
Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L; Fatemi, Mostafa; Alizad, Azra
2015-01-01
To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.
Ji-Wook Jeong; Seung-Hoon Chae; Eun Young Chae; Hak Hee Kim; Young Wook Choi; Sooyeul Lee
2016-08-01
A computer-aided detection (CADe) algorithm for clustered microcalcifications (MCs) in reconstructed digital breast tomosynthesis (DBT) images is suggested. The MC-like objects were enhanced by a Hessian-based 3D calcification response function, and a signal-to-noise ratio (SNR) enhanced image was also generated to screen the MC clustering seed objects. A connected component segmentation method was used to detect the cluster seed objects, which were considered as potential clustering centers of MCs. Bounding cubes for the accepted clustering seed candidate were generated and the overlapping cubes were combined and examined. After the MC clustering and false-positive (FP) reduction step, the average number of FPs was estimated to be 0.87 per DBT volume with a sensitivity of 90.5%.
Cheung, Yun-Chung; Tsai, Hsiu-Pei; Lo, Yung-Feng; Ueng, Shir-Hwa; Huang, Pei-Chin; Chen, Shin-Chih
2016-04-01
To assess the utility of dual-energy contrast-enhanced spectral mammography (DE-CESM) for evaluation of suspicious malignant microcalcifications. Two hundred and fifty-six DE-CESMs were reviewed from 2012-2013, 59 cases fulfilled the following criteria and were enrolled for analysis: (1) suspicious malignant microcalcifications (BI-RADS 4) on mammogram, (2) no related mass, (3) with pathological diagnoses. The microcalcification morphology and associated enhancement were reviewed to analyse the accuracy of the diagnosis and cancer size measurements versus the results of pathology. Of the 59 microcalcifications, 22 were diagnosed as cancers, 19 were atypical lesions and 18 were benign lesions. Twenty (76.9 %) cancers, three (11.55 %) atypia and three (11.55 %) benign lesions revealed enhancement. The true-positive rate of intermediate- and high-concern microcalcifications was significantly higher than that of low-concern lesions (93.75 % vs. 50 %). Overall, the diagnostic sensitivity of enhancement was 90.9 %, with 83.78 % specificity, 76.92 % positive predictive value, 93.94 % negative predictive value and 86.4 % accuracy. Performance was good (AUC = 0.87) according to a ROC curve and cancer size correlation with a mean difference of 0.05 cm on a Bland-Altman plot. DE-CESM provides additional enhancement information for diagnosing breast microcalcifications and measuring cancer sizes with high correlation to surgicohistology. • DE-CESM provides additional enhancement information for diagnosing suspicious breast microcalcifications. • The enhanced cancer size closely correlates to microscopy by Bland-Altman plot. • DE-CESM could be considered for evaluation of suspicious malignant microcalcifications.
Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study
Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L.; Fatemi, Mostafa; Alizad, Azra
2015-01-01
Purpose To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). Methods SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Results Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Conclusions Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis. PMID:26368939
Goodsitt, Mitchell M.; Helvie, Mark A.; Zelakiewicz, Scott; Schmitz, Andrea; Noroozian, Mitra; Paramagul, Chintana; Roubidoux, Marilyn A.; Nees, Alexis V.; Neal, Colleen H.; Carson, Paul; Lu, Yao; Hadjiiski, Lubomir; Wei, Jun
2014-01-01
Purpose To investigate the dependence of microcalcification cluster detectability on tomographic scan angle, angular increment, and number of projection views acquired at digital breast tomosynthesis (DBTdigital breast tomosynthesis). Materials and Methods A prototype DBTdigital breast tomosynthesis system operated in step-and-shoot mode was used to image breast phantoms. Four 5-cm-thick phantoms embedded with 81 simulated microcalcification clusters of three speck sizes (subtle, medium, and obvious) were imaged by using a rhodium target and rhodium filter with 29 kV, 50 mAs, and seven acquisition protocols. Fixed angular increments were used in four protocols (denoted as scan angle, angular increment, and number of projection views, respectively: 16°, 1°, and 17; 24°, 3°, and nine; 30°, 3°, and 11; and 60°, 3°, and 21), and variable increments were used in three (40°, variable, and 13; 40°, variable, and 15; and 60°, variable, and 21). The reconstructed DBTdigital breast tomosynthesis images were interpreted by six radiologists who located the microcalcification clusters and rated their conspicuity. Results The mean sensitivity for detection of subtle clusters ranged from 80% (22.5 of 28) to 96% (26.8 of 28) for the seven DBTdigital breast tomosynthesis protocols; the highest sensitivity was achieved with the 16°, 1°, and 17 protocol (96%), but the difference was significant only for the 60°, 3°, and 21 protocol (80%, P < .002) and did not reach significance for the other five protocols (P = .01–.15). The mean sensitivity for detection of medium and obvious clusters ranged from 97% (28.2 of 29) to 100% (24 of 24), but the differences fell short of significance (P = .08 to >.99). The conspicuity of subtle and medium clusters with the 16°, 1°, and 17 protocol was rated higher than those with other protocols; the differences were significant for subtle clusters with the 24°, 3°, and nine protocol and for medium clusters with 24°, 3°, and nine; 30°, 3°, and 11; 60°, 3° and 21; and 60°, variable, and 21 protocols (P < .002). Conclusion With imaging that did not include x-ray source motion or patient motion during acquisition of the projection views, narrow-angle DBTdigital breast tomosynthesis provided higher sensitivity and conspicuity than wide-angle DBTdigital breast tomosynthesis for subtle microcalcification clusters. © RSNA, 2014 PMID:25007048
Towards the use of computationally inserted lesions for mammographic CAD assessment
NASA Astrophysics Data System (ADS)
Ghanian, Zahra; Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman
2018-03-01
Computer-aided detection (CADe) devices used for breast cancer detection on mammograms are typically first developed and assessed for a specific "original" acquisition system, e.g., a specific image detector. When CADe developers are ready to apply their CADe device to a new mammographic acquisition system, they typically assess the CADe device with images acquired using the new system. Collecting large repositories of clinical images containing verified cancer locations and acquired by the new image acquisition system is costly and time consuming. Our goal is to develop a methodology to reduce the clinical data burden in the assessment of a CADe device for use with a different image acquisition system. We are developing an image blending technique that allows users to seamlessly insert lesions imaged using an original acquisition system into normal images or regions acquired with a new system. In this study, we investigated the insertion of microcalcification clusters imaged using an original acquisition system into normal images acquired with that same system utilizing our previously-developed image blending technique. We first performed a reader study to assess whether experienced observers could distinguish between computationally inserted and native clusters. For this purpose, we applied our insertion technique to clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM) and the Breast Cancer Digital Repository (BCDR). Regions of interest containing microcalcification clusters from one breast of a patient were inserted into the contralateral breast of the same patient. The reader study included 55 native clusters and their 55 inserted counterparts. Analysis of the reader ratings using receiver operating characteristic (ROC) methodology indicated that inserted clusters cannot be reliably distinguished from native clusters (area under the ROC curve, AUC=0.58±0.04). Furthermore, CADe sensitivity was evaluated on mammograms with native and inserted microcalcification clusters using a commercial CADe system. For this purpose, we used full field digital mammograms (FFDMs) from 68 clinical cases, acquired at the University of Michigan Health System. The average sensitivities for native and inserted clusters were equal, 85.3% (58/68). These results demonstrate the feasibility of using the inserted microcalcification clusters for assessing mammographic CAD devices.
NASA Astrophysics Data System (ADS)
Diamant, Idit; Shalhon, Moran; Goldberger, Jacob; Greenspan, Hayit
2016-03-01
Classification of clustered breast microcalcifications into benign and malignant categories is an extremely challenging task for computerized algorithms and expert radiologists alike. In this paper we present a novel method for feature selection based on mutual information (MI) criterion for automatic classification of microcalcifications. We explored the MI based feature selection for various texture features. The proposed method was evaluated on a standardized digital database for screening mammography (DDSM). Experimental results demonstrate the effectiveness and the advantage of using the MI-based feature selection to obtain the most relevant features for the task and thus to provide for improved performance as compared to using all features.
Automated recognition of microcalcification clusters in mammograms
NASA Astrophysics Data System (ADS)
Bankman, Isaac N.; Christens-Barry, William A.; Kim, Dong W.; Weinberg, Irving N.; Gatewood, Olga B.; Brody, William R.
1993-07-01
The widespread and increasing use of mammographic screening for early breast cancer detection is placing a significant strain on clinical radiologists. Large numbers of radiographic films have to be visually interpreted in fine detail to determine the subtle hallmarks of cancer that may be present. We developed an algorithm for detecting microcalcification clusters, the most common and useful signs of early, potentially curable breast cancer. We describe this algorithm, which utilizes contour map representations of digitized mammographic films, and discuss its benefits in overcoming difficulties often encountered in algorithmic approaches to radiographic image processing. We present experimental analyses of mammographic films employing this contour-based algorithm and discuss practical issues relevant to its use in an automated film interpretation instrument.
Soares, Jaqueline S.; Barman, Ishan; Dingari, Narahara Chari; Volynskaya, Zoya; Liu, Wendy; Klein, Nina; Plecha, Donna; Dasari, Ramachandra R.; Fitzmaurice, Maryann
2013-01-01
Microcalcifications geographically target the location of abnormalities within the breast and are of critical importance in breast cancer diagnosis. However, despite stereotactic guidance, core needle biopsy fails to retrieve microcalcifications in up to 15% of patients. Here, we introduce an approach based on diffuse reflectance spectroscopy for detection of microcalcifications that focuses on variations in optical absorption stemming from the calcified clusters and the associated cross-linking molecules. In this study, diffuse reflectance spectra are acquired ex vivo from 203 sites in fresh biopsy tissue cores from 23 patients undergoing stereotactic breast needle biopsies. By correlating the spectra with the corresponding radiographic and histologic assessment, we have developed a support vector machine-derived decision algorithm, which shows high diagnostic power (positive predictive value and negative predictive value of 97% and 88%, respectively) for diagnosis of lesions with microcalcifications. We further show that these results are robust and not due to any spurious correlations. We attribute our findings to the presence of proteins (such as elastin), and desmosine and isodesmosine cross-linkers in the microcalcifications. It is important to note that the performance of the diffuse reflectance decision algorithm is comparable to one derived from the corresponding Raman spectra, and the considerably higher intensity of the reflectance signal enables the detection of the targeted lesions in a fraction of the spectral acquisition time. Our findings create a unique landscape for spectroscopic validation of breast core needle biopsy for detection of microcalcifications that can substantially improve the likelihood of an adequate, diagnostic biopsy in the first attempt. PMID:23267090
Perry, Nicholas M; Patani, N; Milner, S E; Pinker, K; Mokbel, K; Allgood, P C; Duffy, S W
2011-04-01
To compare the diagnostic performance of full-field digital mammography (FFDM) with screen-film mammography (SFM) in a corporate screening programme including younger women. Data were available on 14,946 screening episodes, 5010 FFDM and 9936 SFM. Formal analysis was by logistic regression, adjusting for age and calendar year. FFDM is compared with SFM with reference to cancer detection rates, cancers presenting as clustering microcalcifications, recall rates and PPV of recall. Overall detection rates were 6.4 cancers per thousand screens for FFDM and 2.8 per thousand for SFM (p < 0.001). In women aged 50+ cancer detection was significantly higher for FFDM at 8.6 per thousand vs. 4.0 per thousand, (p = 0.002). In women <50, cancer detection was also significantly higher for FFDM at 4.3 per thousand vs. 1.4 per thousand, (p = 0.02). Cancers detected as clustering microcalcifications increased from 0.4 per thousand with SFM to 2.0 per thousand with FFDM. Rates of assessment recall were higher for FFDM (7.3% vs. 5.0%, p < 0.001). FFDM provided a higher PPV for assessment recall, (32 cancers/364 recalls, 8.8%) than SFM, (28 cancers/493 recalls, 5.7%). Cancer detection rates were significantly higher for FFDM than for SFM, especially for women <50, and cancers detected as clustering microcalcifications.
Columnar cell lesions of the breast: radiological features and histological correlation.
Elif, Aktas; Burcu, Sahin; Nazan, Ciledag; Sumru, Cosar Zehra; Kemal, Arda Niyazi
2015-06-01
This study aimed at investigating the characteristic imaging findings of the columnar cell lesions (CCLs) of the breast via mammography (MG), ultrasonography (US), and magnetic resonance imaging (MRI). The MG, US and MRI findings of 72 patients with histopathological diagnosis of CCLs were retrospectively evaluated. Histopathologically, the CCLs were divided into those with and without atypia; the radiological findings of these two groups were compared with a Chi-square test. Sixty-nine patients underwent stereotaxic biopsy (MG-guided in 50 patients and US-guided in 19 patients) and 3 patients underwent US-guided core needle biopsy; all of these patients were diagnosed with CCLs based on a histological examination. The evaluation of the CCLs in patients that underwent MG-guided stereotaxic biopsy revealed that the most common type of microcalcifications were amorphous-indistinct (52%, n= 26/50) and the most common microcalcification distribution pattern was clustered type (76%, n= 38/50). The ratio of CCLs with atypia was similar in patients with high-risk microcalcifications and in those with benign or intermediate-risk microcalcifications (OR: 1.13, 95% CI: 0.573-2.227, p: 0.475). On the other hand, those patients who underwent US-guided biopsies for the evaluation of CCLs had similar proportions of cystic or solid lesions, posterior acoustic shadowing and contour irregularities whether or not they had atypia (p: 0.584, 0.075, 0.187, respectively). Patients with atypia had a higher number of lesions greater than 1 cm via US as compared to those without atypia, but this difference was not statistically significant (p: 0.06). MRI findings were also similar in patients with and without atypia. MG revealed that clustered distribution patterns and amorphous- indistinct type microcalcifications were more commonly seen in patients with CCLs; however, there was no significant relationship between US or MRI findings and CCLs. In addition, the MG, US and MRI findings were similar in patients with CCLs that did or did not have histopathological characteristics of atypia.
NASA Astrophysics Data System (ADS)
Del Lama, L. S.; Godeli, J.; Poletti, M. E.
2017-08-01
The majority of breast carcinomas can be associated to the presence of calcifications before the development of a mass. However, the overlapping tissues can obscure the visualization of microcalcification clusters due to the reduced contrast-noise ratio (CNR). In order to overcome this complication, one potential solution is the use of the dual-energy (DE) technique, in which two different images are acquired at low (LE) and high (HE) energies or kVp to highlight specific lesions or cancel out tissue background. In this work, the DE features were computationally studied considering simulated acquisitions from a modified PENELOPE Monte Carlo code. The employed irradiation geometry considered typical distances used in digital mammography, a CsI detection system and an updated breast model composed of skin, microcalcifications and glandular and adipose tissues. The breast thickness ranged from 2 to 6 cm with glandularities of 25%, 50% and 75%, where microcalcifications with dimensions from 100 up to 600 μm were positioned. In general, results pointed an efficiency index better than 87% for the microcalcification thicknesses and better than 95% for the glandular ratio. The simulations evaluated in this work can be used to optimize the elements from the DE imaging chain, in order to become a complementary tool for the conventional single-exposure images, especially for the visualization and estimation of calcification thicknesses and glandular ratios.
Scaperrotta, Gianfranco; Ferranti, Claudio; Capalbo, Emanuela; Paolini, Biagio; Marchesini, Monica; Suman, Laura; Folini, Cristina; Mariani, Luigi; Panizza, Pietro
2016-01-01
To assess the diagnostic performance of the BLES as a biopsy tool in patients with ≤ 1 cm clusters of BIRADS 4 microcalcifications, in order to possibly avoid surgical excision in selected patients. This is a retrospective study of 105 patients undergone to stereotactic breast biopsy with the BLES. It excises a single specimen containing the whole mammographic target, allowing better histological assessment due to preserved architecture. Our case series consists of 41 carcinomas (39%) and 64 benign lesions (61%). Cancer involved the specimen margins in 20/41 cases (48.8%) or was close to them (≤ 1 mm) in 14 cases (34.1%); margins were disease-free in only 7 DCIS (17.1%). At subsequent excision of 39/41 malignant cases, underestimation occurred for 5/32 DCIS (15.6%), residual disease was found in 15/39 cancers (38.5%) and no cancer in 19/39 cases (48.7%). For DCIS cases, no residual disease occurred for 66.7% G1-G2 cases and for 35.3% G3 cases (P=0.1556) as well as in 83.3%, 40.0% and 43.8% cases respectively for negative, close and positive BLES margins (P=0.2576). The BLES is a good option for removal of small clusters of breast microcalcifications, giving better histological interpretation, lower underestimation rates and possibly reducing the need of subsequent surgical excision in selected patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Costaridou, Lena
Although a wide variety of Computer-Aided Diagnosis (CADx) schemes have been proposed across breast imaging modalities, and especially in mammography, research is still ongoing to meet the high performance CADx requirements. In this chapter, methodological contributions to CADx in mammography and adjunct breast imaging modalities are reviewed, as they play a major role in early detection, diagnosis and clinical management of breast cancer. At first, basic terms and definitions are provided. Then, emphasis is given to lesion content derivation, both anatomical and functional, considering only quantitative image features of micro-calcification clusters and masses across modalities. Additionally, two CADx application examples are provided. The first example investigates the effect of segmentation accuracy on micro-calcification cluster morphology derivation in X-ray mammography. The second one demonstrates the efficiency of texture analysis in quantification of enhancement kinetics, related to vascular heterogeneity, for mass classification in dynamic contrast-enhanced magnetic resonance imaging.
Multiplexed wavelet transform technique for detection of microcalcification in digitized mammograms.
Mini, M G; Devassia, V P; Thomas, Tessamma
2004-12-01
Wavelet transform (WT) is a potential tool for the detection of microcalcifications, an early sign of breast cancer. This article describes the implementation and evaluates the performance of two novel WT-based schemes for the automatic detection of clustered microcalcifications in digitized mammograms. Employing a one-dimensional WT technique that utilizes the pseudo-periodicity property of image sequences, the proposed algorithms achieve high detection efficiency and low processing memory requirements. The detection is achieved from the parent-child relationship between the zero-crossings [Marr-Hildreth (M-H) detector] /local extrema (Canny detector) of the WT coefficients at different levels of decomposition. The detected pixels are weighted before the inverse transform is computed, and they are segmented by simple global gray level thresholding. Both detectors produce 95% detection sensitivity, even though there are more false positives for the M-H detector. The M-H detector preserves the shape information and provides better detection sensitivity for mammograms containing widely distributed calcifications.
Modeling of digital mammograms using bicubic spline functions and additive noise
NASA Astrophysics Data System (ADS)
Graffigne, Christine; Maintournam, Aboubakar; Strauss, Anne
1998-09-01
The purpose of our work is the microcalcifications detection on digital mammograms. In order to do so, we model the grey levels of digital mammograms by the sum of a surface trend (bicubic spline function) and an additive noise or texture. We also introduce a robust estimation method in order to overcome the bias introduced by the microcalcifications. After the estimation we consider the subtraction image values as noise. If the noise is not correlated, we adjust its distribution probability by the Pearson's system of densities. It allows us to threshold accurately the images of subtraction and therefore to detect the microcalcifications. If the noise is correlated, a unilateral autoregressive process is used and its coefficients are again estimated by the least squares method. We then consider non overlapping windows on the residues image. In each window the texture residue is computed and compared with an a priori threshold. This provides correct localization of the microcalcifications clusters. However this technique is definitely more time consuming that then automatic threshold assuming uncorrelated noise and does not lead to significantly better results. As a conclusion, even if the assumption of uncorrelated noise is not correct, the automatic thresholding based on the Pearson's system performs quite well on most of our images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Samala, Ravi K., E-mail: rsamala@umich.edu; Chan, Heang-Ping; Lu, Yao
Purpose: Develop a computer-aided detection (CADe) system for clustered microcalcifications in digital breast tomosynthesis (DBT) volume enhanced with multiscale bilateral filtering (MSBF) regularization. Methods: With Institutional Review Board approval and written informed consent, two-view DBT of 154 breasts, of which 116 had biopsy-proven microcalcification (MC) clusters and 38 were free of MCs, was imaged with a General Electric GEN2 prototype DBT system. The DBT volumes were reconstructed with MSBF-regularized simultaneous algebraic reconstruction technique (SART) that was designed to enhance MCs and reduce background noise while preserving the quality of other tissue structures. The contrast-to-noise ratio (CNR) of MCs was furthermore » improved with enhancement-modulated calcification response (EMCR) preprocessing, which combined multiscale Hessian response to enhance MCs by shape and bandpass filtering to remove the low-frequency structured background. MC candidates were then located in the EMCR volume using iterative thresholding and segmented by adaptive region growing. Two sets of potential MC objects, cluster centroid objects and MC seed objects, were generated and the CNR of each object was calculated. The number of candidates in each set was controlled based on the breast volume. Dynamic clustering around the centroid objects grouped the MC candidates to form clusters. Adaptive criteria were designed to reduce false positive (FP) clusters based on the size, CNR values and the number of MCs in the cluster, cluster shape, and cluster based maximum intensity projection. Free-response receiver operating characteristic (FROC) and jackknife alternative FROC (JAFROC) analyses were used to assess the performance and compare with that of a previous study. Results: Unpaired two-tailedt-test showed a significant increase (p < 0.0001) in the ratio of CNRs for MCs with and without MSBF regularization compared to similar ratios for FPs. For view-based detection, a sensitivity of 85% was achieved at an FP rate of 2.16 per DBT volume. For case-based detection, a sensitivity of 85% was achieved at an FP rate of 0.85 per DBT volume. JAFROC analysis showed a significant improvement in the performance of the current CADe system compared to that of our previous system (p = 0.003). Conclusions: MBSF regularized SART reconstruction enhances MCs. The enhancement in the signals, in combination with properly designed adaptive threshold criteria, effective MC feature analysis, and false positive reduction techniques, leads to a significant improvement in the detection of clustered MCs in DBT.« less
Automatic insertion of simulated microcalcification clusters in a software breast phantom
NASA Astrophysics Data System (ADS)
Shankla, Varsha; Pokrajac, David D.; Weinstein, Susan P.; DeLeo, Michael; Tuite, Catherine; Roth, Robyn; Conant, Emily F.; Maidment, Andrew D.; Bakic, Predrag R.
2014-03-01
An automated method has been developed to insert realistic clusters of simulated microcalcifications (MCs) into computer models of breast anatomy. This algorithm has been developed as part of a virtual clinical trial (VCT) software pipeline, which includes the simulation of breast anatomy, mechanical compression, image acquisition, image processing, display and interpretation. An automated insertion method has value in VCTs involving large numbers of images. The insertion method was designed to support various insertion placement strategies, governed by probability distribution functions (pdf). The pdf can be predicated on histological or biological models of tumor growth, or estimated from the locations of actual calcification clusters. To validate the automated insertion method, a 2-AFC observer study was designed to compare two placement strategies, undirected and directed. The undirected strategy could place a MC cluster anywhere within the phantom volume. The directed strategy placed MC clusters within fibroglandular tissue on the assumption that calcifications originate from epithelial breast tissue. Three radiologists were asked to select between two simulated phantom images, one from each placement strategy. Furthermore, questions were posed to probe the rationale behind the observer's selection. The radiologists found the resulting cluster placement to be realistic in 92% of cases, validating the automated insertion method. There was a significant preference for the cluster to be positioned on a background of adipose or mixed adipose/fibroglandular tissues. Based upon these results, this automated lesion placement method will be included in our VCT simulation pipeline.
Wang, Juan; Nishikawa, Robert M; Yang, Yongyi
2017-04-01
In computerized detection of clustered microcalcifications (MCs) from mammograms, the traditional approach is to apply a pattern detector to locate the presence of individual MCs, which are subsequently grouped into clusters. Such an approach is often susceptible to the occurrence of false positives (FPs) caused by local image patterns that resemble MCs. We investigate the feasibility of a direct detection approach to determining whether an image region contains clustered MCs or not. Toward this goal, we develop a deep convolutional neural network (CNN) as the classifier model to which the input consists of a large image window ([Formula: see text] in size). The multiple layers in the CNN classifier are trained to automatically extract image features relevant to MCs at different spatial scales. In the experiments, we demonstrated this approach on a dataset consisting of both screen-film mammograms and full-field digital mammograms. We evaluated the detection performance both on classifying image regions of clustered MCs using a receiver operating characteristic (ROC) analysis and on detecting clustered MCs from full mammograms by a free-response receiver operating characteristic analysis. For comparison, we also considered a recently developed MC detector with FP suppression. In classifying image regions of clustered MCs, the CNN classifier achieved 0.971 in the area under the ROC curve, compared to 0.944 for the MC detector. In detecting clustered MCs from full mammograms, at 90% sensitivity, the CNN classifier obtained an FP rate of 0.69 clusters/image, compared to 1.17 clusters/image by the MC detector. These results indicate that using global image features can be more effective in discriminating clustered MCs from FPs caused by various sources, such as linear structures, thereby providing a more accurate detection of clustered MCs on mammograms.
NASA Astrophysics Data System (ADS)
Cockmartin, Lesley; Marshall, Nicholas W.; Van Ongeval, Chantal; Aerts, Gwen; Stalmans, Davina; Zanca, Federica; Shaheen, Eman; De Keyzer, Frederik; Dance, David R.; Young, Kenneth C.; Bosmans, Hilde
2015-05-01
This paper introduces a hybrid method for performing detection studies in projection image based modalities, based on image acquisitions of target objects and patients. The method was used to compare 2D mammography and digital breast tomosynthesis (DBT) in terms of the detection performance of spherical densities and microcalcifications. The method starts with the acquisition of spheres of different glandular equivalent densities and microcalcifications of different sizes immersed in a homogeneous breast tissue simulating medium. These target objects are then segmented and the subsequent templates are fused in projection images of patients and processed or reconstructed. This results in hybrid images with true mammographic anatomy and clinically relevant target objects, ready for use in observer studies. The detection study of spherical densities used 108 normal and 178 hybrid 2D and DBT images; 156 normal and 321 hybrid images were used for the microcalcifications. Seven observers scored the presence/absence of the spheres/microcalcifications in a square region via a 5-point confidence rating scale. Detection performance in 2D and DBT was compared via ROC analysis with sub-analyses for the density of the spheres, microcalcification size, breast thickness and z-position. The study was performed on a Siemens Inspiration tomosynthesis system using patient acquisitions with an average age of 58 years and an average breast thickness of 53 mm providing mean glandular doses of 1.06 mGy (2D) and 2.39 mGy (DBT). Study results showed that breast tomosynthesis (AUC = 0.973) outperformed 2D (AUC = 0.831) for the detection of spheres (p < 0.0001) and this applied for all spherical densities and breast thicknesses. By way of contrast, DBT was worse than 2D for microcalcification detection (AUC2D = 0.974, AUCDBT = 0.838, p < 0.0001), with significant differences found for all sizes (150-354 µm), for breast thicknesses above 40 mm and for heights above the detector of 20 mm and above. In conclusion, the hybrid method was successfully used to produce images for a detection study; results showed breast tomosynthesis outperformed 2D for spherical densities while further optimization of DBT for microcalcifications is suggested.
NASA Astrophysics Data System (ADS)
Bemelmans, Frédéric; Rashidnasab, Alaleh; Chesterman, Frédérique; Kimpe, Tom; Bosmans, Hilde
2016-03-01
Purpose: To evaluate lesion detectability and reading time as a function of luminance level of the monitor. Material and Methods: 3D mass models and microcalcification clusters were simulated into ROIs of for processing mammograms. Randomly selected ROIs were subdivided in three groups according to their background glandularity: high (>30%), medium (15-30%) and low (<15%). 6 non-spiculated masses (9 - 11mm), 6 spiculated masses (5 - 7mm) and 6 microcalcification clusters (2 - 4mm) were scaled in 3D to create a range of sizes. The linear attenuation coefficient (AC) of the masses was adjusted from 100% glandular tissue to 90%, 80%, 70%, to create different contrasts. Six physicists read the full database on Barco's Coronis Uniti monitor for four different luminance levels (300, 800, 1000 and 1200 Cd/m2), using a 4-AFC tool. Percentage correct (PC) and time were computed for all different conditions. A paired t-test was performed to evaluate the effect of luminance on PC and time. A multi-factorial analysis was performed using MANOVA.. Results: Paired t-test indicated a statistically significant difference for the average time per session between 300 and 1200; 800 and 1200; 1000 and 1200 Cd/m2, for all participants combined. There was no effect on PC. MANOVA denoted significantly lower reading times for high glandularity images at 1200 Cd/m2. Both types of masses were significantly faster detected at 1200 Cd/m2, for the contrast study. In the size study, microcalcification clusters and spiculated masses had a significantly higher detection rate at 1200 Cd/m2. Conclusion: These results demonstrate a significant decrease in reading time, while detectability remained constant.
Slapa, Rafal Z.; Piwowonski, Antoni; Jakubowski, Wieslaw S.; Bierca, Jacek; Szopinski, Kazimierz T.; Slowinska-Srzednicka, Jadwiga; Migda, Bartosz; Mlosek, R. Krzysztof
2012-01-01
Although elastography can enhance the differential diagnosis of thyroid nodules, its diagnostic performance is not ideal at present. Further improvements in the technique and creation of robust diagnostic criteria are necessary. The purpose of this study was to compare the usefulness of strain elastography and a new generation of elasticity imaging called supersonic shear wave elastography (SSWE) in differential evaluation of thyroid nodules. Six thyroid nodules in 4 patients were studied. SSWE yielded 1 true-positive and 5 true-negative results. Strain elastography yielded 5 false-positive results and 1 false-negative result. A novel finding appreciated with SSWE, were punctate foci of increased stiffness corresponding to microcalcifications in 4 nodules, some not visible on B-mode ultrasound, as opposed to soft, colloid-inspissated areas visible on B-mode ultrasound in 2 nodules. This preliminary paper indicates that SSWE may outperform strain elastography in differentiation of thyroid nodules with regard to their stiffness. SSWE showed the possibility of differentiation of high echogenic foci into microcalcifications and inspissated colloid, adding a new dimension to thyroid elastography. Further multicenter large-scale studies of thyroid nodules evaluating different elastographic methods are warranted. PMID:22685685
NASA Astrophysics Data System (ADS)
Nishikawa, Robert M.; Giger, Maryellen L.; Doi, Kunio; Vyborny, Carl J.; Schmidt, Robert A.; Metz, Charles E.; Wu, Chris Y.; Yin, Fang-Fang; Jiang, Yulei; Huo, Zhimin; Lu, Ping; Zhang, Wei; Ema, Takahiro; Bick, Ulrich; Papaioannou, John; Nagel, Rufus H.
1993-07-01
We are developing an 'intelligent' workstation to assist radiologists in diagnosing breast cancer from mammograms. The hardware for the workstation will consist of a film digitizer, a high speed computer, a large volume storage device, a film printer, and 4 high resolution CRT monitors. The software for the workstation is a comprehensive package of automated detection and classification schemes. Two rule-based detection schemes have been developed, one for breast masses and the other for clustered microcalcifications. The sensitivity of both schemes is 85% with a false-positive rate of approximately 3.0 and 1.5 false detections per image, for the mass and cluster detection schemes, respectively. Computerized classification is performed by an artificial neural network (ANN). The ANN has a sensitivity of 100% with a specificity of 60%. Currently, the ANN, which is a three-layer, feed-forward network, requires as input ratings of 14 different radiographic features of the mammogram that were determined subjectively by a radiologist. We are in the process of developing automated techniques to objectively determine these 14 features. The workstation will be placed in the clinical reading area of the radiology department in the near future, where controlled clinical tests will be performed to measure its efficacy.
Evaluation of clinical image processing algorithms used in digital mammography.
Zanca, Federica; Jacobs, Jurgen; Van Ongeval, Chantal; Claus, Filip; Celis, Valerie; Geniets, Catherine; Provost, Veerle; Pauwels, Herman; Marchal, Guy; Bosmans, Hilde
2009-03-01
Screening is the only proven approach to reduce the mortality of breast cancer, but significant numbers of breast cancers remain undetected even when all quality assurance guidelines are implemented. With the increasing adoption of digital mammography systems, image processing may be a key factor in the imaging chain. Although to our knowledge statistically significant effects of manufacturer-recommended image processings have not been previously demonstrated, the subjective experience of our radiologists, that the apparent image quality can vary considerably between different algorithms, motivated this study. This article addresses the impact of five such algorithms on the detection of clusters of microcalcifications. A database of unprocessed (raw) images of 200 normal digital mammograms, acquired with the Siemens Novation DR, was collected retrospectively. Realistic simulated microcalcification clusters were inserted in half of the unprocessed images. All unprocessed images were subsequently processed with five manufacturer-recommended image processing algorithms (Agfa Musica 1, IMS Raffaello Mammo 1.2, Sectra Mamea AB Sigmoid, Siemens OPVIEW v2, and Siemens OPVIEW v1). Four breast imaging radiologists were asked to locate and score the clusters in each image on a five point rating scale. The free-response data were analyzed by the jackknife free-response receiver operating characteristic (JAFROC) method and, for comparison, also with the receiver operating characteristic (ROC) method. JAFROC analysis revealed highly significant differences between the image processings (F = 8.51, p < 0.0001), suggesting that image processing strongly impacts the detectability of clusters. Siemens OPVIEW2 and Siemens OPVIEW1 yielded the highest and lowest performances, respectively. ROC analysis of the data also revealed significant differences between the processing but at lower significance (F = 3.47, p = 0.0305) than JAFROC. Both statistical analysis methods revealed that the same six pairs of modalities were significantly different, but the JAFROC confidence intervals were about 32% smaller than ROC confidence intervals. This study shows that image processing has a significant impact on the detection of microcalcifications in digital mammograms. Objective measurements, such as described here, should be used by the manufacturers to select the optimal image processing algorithm.
Effect of image quality on calcification detection in digital mammography
Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M.; Wallis, Matthew G.; Chakraborty, Dev P.; Dance, David R.; Bosmans, Hilde; Young, Kenneth C.
2012-01-01
Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection. PMID:22755704
Effect of image quality on calcification detection in digital mammography.
Warren, Lucy M; Mackenzie, Alistair; Cooke, Julie; Given-Wilson, Rosalind M; Wallis, Matthew G; Chakraborty, Dev P; Dance, David R; Bosmans, Hilde; Young, Kenneth C
2012-06-01
This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection. © 2012 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, Lucy M.; Mackenzie, Alistair; Cooke, Julie
Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into halfmore » of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.« less
Ning, Chun-Ping; Ji, Qing-Lian; Fang, Shi-Bao; Wang, Hong-Qiao; Zhong, Yan-Mi; Niu, Hai-Tao
2018-06-01
The aim of this study was to compare the distribution patterns of microcalcifications in thyroid cancers with benign cases. In total, 358 patients having microcalcifications on ultrasonography were analysed. Microcalcifications were categorised according to the distribution patterns: (I) microcalcifications inside one (a) or more (b) suspected nodules, (II) microcalcifications not only inside but also surrounding a suspected single (a) or multiple (b) nodules, and (III) focal (a) or diffuse (b) microcalcifications in the absence of any suspected nodule. Differences in distribution patterns of microcalcifications in benign and malignant thyroid lesions were compared. We found that the distribution patterns of microcalcifications differed between malignant (n = 325) and benign lesions (n = 117) (X 2 = 9.926, p < 0.01). Benign lesions were classified as type Ia (66.7%), type Ib (29.1%) or type IIIa (4.3%). The specificity of type II and type IIIb in diagnosing malignant cases was 100%. Among malignant lesions, 172 locations were classified as type Ia, 106 as type Ib, 12 as type IIa, 7 as IIb, 7 as type IIIa and 19 as type IIIb. Accompanying Hashimoto thyroiditis was most frequent in type III (51.6%). Types II and IIIb are highly specific for cancer detection. Microcalcifications outside a nodule and those detected in the absence of any nodule should therefore be reviewed carefully in clinical practice. • A method to classify distribution patterns of thyroid microcalcifications is presented. • Distribution features of microcalcifications are useful for diagnosing thyroid cancers. • Microcalcifications outside a suspicious nodule are highly specific for thyroid cancers. • Microcalcifications without suspicious nodules should also alert the physician to thyroid cancers.
Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B
2018-06-12
To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Schulz-Wendtland, R; Hermann, K-P; Adamietz, B; Meier-Meitinger, M; Wenkel, E; Lell, M; Anders, K; Uder, M
2011-02-01
The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.
Discrimination of Breast Cancer with Microcalcifications on Mammography by Deep Learning.
Wang, Jinhua; Yang, Xi; Cai, Hongmin; Tan, Wanchang; Jin, Cangzheng; Li, Li
2016-06-07
Microcalcification is an effective indicator of early breast cancer. To improve the diagnostic accuracy of microcalcifications, this study evaluates the performance of deep learning-based models on large datasets for its discrimination. A semi-automated segmentation method was used to characterize all microcalcifications. A discrimination classifier model was constructed to assess the accuracies of microcalcifications and breast masses, either in isolation or combination, for classifying breast lesions. Performances were compared to benchmark models. Our deep learning model achieved a discriminative accuracy of 87.3% if microcalcifications were characterized alone, compared to 85.8% with a support vector machine. The accuracies were 61.3% for both methods with masses alone and improved to 89.7% and 85.8% after the combined analysis with microcalcifications. Image segmentation with our deep learning model yielded 15, 26 and 41 features for the three scenarios, respectively. Overall, deep learning based on large datasets was superior to standard methods for the discrimination of microcalcifications. Accuracy was increased by adopting a combinatorial approach to detect microcalcifications and masses simultaneously. This may have clinical value for early detection and treatment of breast cancer.
Discrimination of Breast Cancer with Microcalcifications on Mammography by Deep Learning
Wang, Jinhua; Yang, Xi; Cai, Hongmin; Tan, Wanchang; Jin, Cangzheng; Li, Li
2016-01-01
Microcalcification is an effective indicator of early breast cancer. To improve the diagnostic accuracy of microcalcifications, this study evaluates the performance of deep learning-based models on large datasets for its discrimination. A semi-automated segmentation method was used to characterize all microcalcifications. A discrimination classifier model was constructed to assess the accuracies of microcalcifications and breast masses, either in isolation or combination, for classifying breast lesions. Performances were compared to benchmark models. Our deep learning model achieved a discriminative accuracy of 87.3% if microcalcifications were characterized alone, compared to 85.8% with a support vector machine. The accuracies were 61.3% for both methods with masses alone and improved to 89.7% and 85.8% after the combined analysis with microcalcifications. Image segmentation with our deep learning model yielded 15, 26 and 41 features for the three scenarios, respectively. Overall, deep learning based on large datasets was superior to standard methods for the discrimination of microcalcifications. Accuracy was increased by adopting a combinatorial approach to detect microcalcifications and masses simultaneously. This may have clinical value for early detection and treatment of breast cancer. PMID:27273294
Wang, Juan; Nishikawa, Robert M; Yang, Yongyi
2016-01-01
In computer-aided detection of microcalcifications (MCs), the detection accuracy is often compromised by frequent occurrence of false positives (FPs), which can be attributed to a number of factors, including imaging noise, inhomogeneity in tissue background, linear structures, and artifacts in mammograms. In this study, the authors investigated a unified classification approach for combating the adverse effects of these heterogeneous factors for accurate MC detection. To accommodate FPs caused by different factors in a mammogram image, the authors developed a classification model to which the input features were adapted according to the image context at a detection location. For this purpose, the input features were defined in two groups, of which one group was derived from the image intensity pattern in a local neighborhood of a detection location, and the other group was used to characterize how a MC is different from its structural background. Owing to the distinctive effect of linear structures in the detector response, the authors introduced a dummy variable into the unified classifier model, which allowed the input features to be adapted according to the image context at a detection location (i.e., presence or absence of linear structures). To suppress the effect of inhomogeneity in tissue background, the input features were extracted from different domains aimed for enhancing MCs in a mammogram image. To demonstrate the flexibility of the proposed approach, the authors implemented the unified classifier model by two widely used machine learning algorithms, namely, a support vector machine (SVM) classifier and an Adaboost classifier. In the experiment, the proposed approach was tested for two representative MC detectors in the literature [difference-of-Gaussians (DoG) detector and SVM detector]. The detection performance was assessed using free-response receiver operating characteristic (FROC) analysis on a set of 141 screen-film mammogram (SFM) images (66 cases) and a set of 188 full-field digital mammogram (FFDM) images (95 cases). The FROC analysis results show that the proposed unified classification approach can significantly improve the detection accuracy of two MC detectors on both SFM and FFDM images. Despite the difference in performance between the two detectors, the unified classifiers can reduce their FP rate to a similar level in the output of the two detectors. In particular, with true-positive rate at 85%, the FP rate on SFM images for the DoG detector was reduced from 1.16 to 0.33 clusters/image (unified SVM) and 0.36 clusters/image (unified Adaboost), respectively; similarly, for the SVM detector, the FP rate was reduced from 0.45 clusters/image to 0.30 clusters/image (unified SVM) and 0.25 clusters/image (unified Adaboost), respectively. Similar FP reduction results were also achieved on FFDM images for the two MC detectors. The proposed unified classification approach can be effective for discriminating MCs from FPs caused by different factors (such as MC-like noise patterns and linear structures) in MC detection. The framework is general and can be applicable for further improving the detection accuracy of existing MC detectors.
Changing patterns of microcalcification on screening mammography for prediction of breast cancer.
Kim, Kwan Il; Lee, Kyung Hee; Kim, Tae Ryung; Chun, Yong Soon; Lee, Tae Hoon; Choi, Hye Young; Park, Heung Kyu
2016-05-01
The presence of microcalcification on mammography is one of the earliest signs in breast cancer detection. However, it is difficult to distinguish malignant calcifications from benign calcifications. The aim of this study is to evaluate correlation between changing patterns of microcalcification on screening mammography and malignant breast lesions. Medical records and diagnostic images of 67 women who had previously undergone at least two digital mammograms at least 6 months apart and underwent mammography-guided needle localization and surgical excision between 2011 and 2013 were retrospectively reviewed and analyzed. Breast cancer was detected in the surgical specimens of 20 patients (29.9 %). Annual change of extent of microcalcification on mammography showed statistically significant correlation with pathologic outcome (P = 0.023). The changing pattern of new appearance or increased extent of microcalcification on mammography had positive predictive value of 54.8 % for breast cancer, and it was a statistically significant predictor for breast cancer (P = 0.012). Shape or number change of microcalcification without increased extent had less accurate predictive value for breast cancer, particularly in women younger than 50 years (P < 0.001). This study showed that the pattern of increased extent of microcalcification on screening mammography was a significant predictor for breast cancer. We suggest that mammography-guided needle localization and surgical excision should be considered when increased extent of microcalcification is observed on screening mammography and closed follow-up without pathologic confirmation can be permitted if absence of extension of microcalcification was confirmed in women younger than 50 years.
[Explorations of breast microcalcifications: Guidelines].
Chamming's, F; Chopier, J; Mathelin, C; Chéreau, E
2015-12-01
To assess imaging performances for the detection, characterization and biopsy of breast microcalcifications and make recommendations. French and English publications were searched using PubMed, Cochrane Library and international learned societies recommendations. Digital mammography (DR [Direct Radiography] and CR [Computed Radiography]) and screen-film mammography demonstrate good performances for the detection and the characterization of breast microcalcifications. Systematic use of the 2013 edition of the BI-RADS lexicon is recommended for description and characterization of microcalcifications. Faced with BI-RADS 4 or 5 microcalcifications, breast ultrasound is recommended but a normal result does not eliminate the diagnosis of cancer and other examination should be performed. Literature review does not allow recommending digital breast tomosynthesis, elastography or MRI to analyze microcalcifications. In case of probably benign microcalcifications (BI-RADS 3), six months, one year and at least two years follow-up are recommended. In case a biopsy is indicated, it is recommended to use a vacuum-assisted macrobiopsy system with 11-gauges needles or bigger. If no calcification is visible on the radiography of the specimen, it is recommended to obtain additional samples. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Automated analysis for microcalcifications in high resolution digital mammograms
Mascio, Laura N.
1996-01-01
A method for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs.
Automated analysis for microcalcifications in high resolution digital mammograms
Mascio, L.N.
1996-12-17
A method is disclosed for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs. 8 figs.
[Examination of Stereotactic Mammotome Biopsy for Microcalcification in Our Hospital].
Sueoka, Noriko; Ishizuka, Mariko; Yoshikawa, Katsuhiro; Tsubota, Yu; Yamamoto, Daigo; Kon, Masanori
2017-11-01
We introduced stereotactic mammotome biopsy(ST-MMT)for the purpose of screening and other institutions. There are many benign cases to be diagnosed by pathological findings, so it is thought to be necessary to examine the adaptation of STMMT again. We examined the performance of ST-MMT in a case of a non-palpating calcification lesion. Between August 2013 and December 2016, ST-MMT biopsies were performed for 247 microcalcified lesions revealed by mammography(in both breasts in 9 patients; twice in the ipsilateral breast in 2 patients). The mean age of all patients was 46 years(range, 24- 89 years). We found 39 cases(15.8%)of breast cancer. A final diagnosis of breast cancer was made in 39 patients, who comprised 0% of those with Category 2, 53.8% of those with Category 3, 35.9% of those with Category 4, and 10.3% of those with Category 5. Regarding the morphology and distribution of microcalcifications, breast cancer accounted for 46.2%, 5.1%, 2.6%, 35.9%, 7.7%, and 2.6% of the cases with small round/clustered, amorphous/clustered, pleomorphic/clus- tered, pleomorphic/linear segmental, and fine linear/clustered patterns, respectively. Also, we examined each of the patients, (1) who underwent mammography for medical examinations, (2) who underwent mammography performed at other institutions, (3) who underwent follow-up for microcalcifications and postoperative follow-up mammography. The proportions of breast cancer diagnoses were (1) 11.4%, (2) 20.6%, and (3) 7.1%. Proportions of Category 3 breast cancer were (1) 10.3%, (2) 38.5%, and (3) 5.1%. Among the cases in which ST-MMT was performed in this study, Category 3 accounted for more than half. However, 10.9%(21/192 lesions)were diagnosed as malignant in Category 3. The diagnosis of breast cancer in pa- tients who underwent mammography performed at other institutions was not observed in 79.4%(104/131 lesions), and among the 104 lesions, as a result of reassessment of calcification in our hospital, Category 2 was also included. Calcification in Category 2 lesions was benign in all cases. It was suggested that the indication for ST-MMT biopsy could be further narrowed down by being careful not to over-diagnose.
Secretory pathway Ca2+ -ATPases promote in vitro microcalcifications in breast cancer cells.
Dang, Donna; Prasad, Hari; Rao, Rajini
2017-11-01
Calcification of the breast is often an outward manifestation of underlying molecular changes that drive carcinogenesis. Up to 50% of all non-palpable breast tumors and 90% of ductal carcinoma in situ present with radiographically dense mineralization in mammographic scans. However, surprisingly little is known about the molecular pathways that lead to microcalcifications in the breast. Here, we report on a rapid and quantitative in vitro assay to monitor microcalcifications in breast cancer cell lines, including MCF7, MDA-MB-231, and Hs578T. We show that the Secretory Pathway Ca 2+ -ATPases SPCA1 and SPCA2 are strongly induced under osteogenic conditions that elicit microcalcifications. SPCA gene expression is significantly elevated in breast cancer subtypes that are associated with microcalcifications. Ectopic expression of SPCA genes drives microcalcifications and is dependent on pumping activity. Conversely, knockdown of SPCA expression significantly attenuates formation of microcalcifications. We propose that high levels of SPCA pumps may initiate mineralization in the secretory pathway by elevating luminal Ca 2+ . Our new findings offer mechanistic insight and functional implications on a widely observed, yet poorly understood radiographic signature of breast cancer. © 2017 Wiley Periodicals, Inc.
A two-stage method for microcalcification cluster segmentation in mammography by deformable models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arikidis, N.; Kazantzi, A.; Skiadopoulos, S.
Purpose: Segmentation of microcalcification (MC) clusters in x-ray mammography is a difficult task for radiologists. Accurate segmentation is prerequisite for quantitative image analysis of MC clusters and subsequent feature extraction and classification in computer-aided diagnosis schemes. Methods: In this study, a two-stage semiautomated segmentation method of MC clusters is investigated. The first stage is targeted to accurate and time efficient segmentation of the majority of the particles of a MC cluster, by means of a level set method. The second stage is targeted to shape refinement of selected individual MCs, by means of an active contour model. Both methods aremore » applied in the framework of a rich scale-space representation, provided by the wavelet transform at integer scales. Segmentation reliability of the proposed method in terms of inter and intraobserver agreements was evaluated in a case sample of 80 MC clusters originating from the digital database for screening mammography, corresponding to 4 morphology types (punctate: 22, fine linear branching: 16, pleomorphic: 18, and amorphous: 24) of MC clusters, assessing radiologists’ segmentations quantitatively by two distance metrics (Hausdorff distance—HDIST{sub cluster}, average of minimum distance—AMINDIST{sub cluster}) and the area overlap measure (AOM{sub cluster}). The effect of the proposed segmentation method on MC cluster characterization accuracy was evaluated in a case sample of 162 pleomorphic MC clusters (72 malignant and 90 benign). Ten MC cluster features, targeted to capture morphologic properties of individual MCs in a cluster (area, major length, perimeter, compactness, and spread), were extracted and a correlation-based feature selection method yielded a feature subset to feed in a support vector machine classifier. Classification performance of the MC cluster features was estimated by means of the area under receiver operating characteristic curve (Az ± Standard Error) utilizing tenfold cross-validation methodology. A previously developed B-spline active rays segmentation method was also considered for comparison purposes. Results: Interobserver and intraobserver segmentation agreements (median and [25%, 75%] quartile range) were substantial with respect to the distance metrics HDIST{sub cluster} (2.3 [1.8, 2.9] and 2.5 [2.1, 3.2] pixels) and AMINDIST{sub cluster} (0.8 [0.6, 1.0] and 1.0 [0.8, 1.2] pixels), while moderate with respect to AOM{sub cluster} (0.64 [0.55, 0.71] and 0.59 [0.52, 0.66]). The proposed segmentation method outperformed (0.80 ± 0.04) statistically significantly (Mann-Whitney U-test, p < 0.05) the B-spline active rays segmentation method (0.69 ± 0.04), suggesting the significance of the proposed semiautomated method. Conclusions: Results indicate a reliable semiautomated segmentation method for MC clusters offered by deformable models, which could be utilized in MC cluster quantitative image analysis.« less
Fused man-machine classification schemes to enhance diagnosis of breast microcalcifications
NASA Astrophysics Data System (ADS)
Andreadis, Ioannis; Sevastianos, Chatzistergos; George, Spyrou; Konstantina, Nikita
2017-11-01
Computer aided diagnosis (CAD x ) approaches are developed towards the effective discrimination between benign and malignant clusters of microcalcifications. Different sources of information are exploited, such as features extracted from the image analysis of the region of interest, features related to the location of the cluster inside the breast, age of the patient and descriptors provided by the radiologists while performing their diagnostic task. A series of different CAD x schemes are implemented, each of which uses a different category of features and adopts a variety of machine learning algorithms and alternative image processing techniques. A novel framework is introduced where these independent diagnostic components are properly combined according to features critical to a radiologist in an attempt to identify the most appropriate CAD x schemes for the case under consideration. An open access database (Digital Database of Screening Mammography (DDSM)) has been elaborated to construct a large dataset with cases of varying subtlety, in order to ensure the development of schemes with high generalization ability, as well as extensive evaluation of their performance. The obtained results indicate that the proposed framework succeeds in improving the diagnostic procedure, as the achieved overall classification performance outperforms all the independent single diagnostic components, as well as the radiologists that assessed the same cases, in terms of accuracy, sensitivity, specificity and area under the curve following receiver operating characteristic analysis.
A prototype of mammography CADx scheme integrated to imaging quality evaluation techniques
NASA Astrophysics Data System (ADS)
Schiabel, Homero; Matheus, Bruno R. N.; Angelo, Michele F.; Patrocínio, Ana Claudia; Ventura, Liliane
2011-03-01
As all women over the age of 40 are recommended to perform mammographic exams every two years, the demands on radiologists to evaluate mammographic images in short periods of time has increased considerably. As a tool to improve quality and accelerate analysis CADe/Dx (computer-aided detection/diagnosis) schemes have been investigated, but very few complete CADe/Dx schemes have been developed and most are restricted to detection and not diagnosis. The existent ones usually are associated to specific mammographic equipment (usually DR), which makes them very expensive. So this paper describes a prototype of a complete mammography CADx scheme developed by our research group integrated to an imaging quality evaluation process. The basic structure consists of pre-processing modules based on image acquisition and digitization procedures (FFDM, CR or film + scanner), a segmentation tool to detect clustered microcalcifications and suspect masses and a classification scheme, which evaluates as the presence of microcalcifications clusters as well as possible malignant masses based on their contour. The aim is to provide enough information not only on the detected structures but also a pre-report with a BI-RADS classification. At this time the system is still lacking an interface integrating all the modules. Despite this, it is functional as a prototype for clinical practice testing, with results comparable to others reported in literature.
Breast Microcalcification Detection Using Super-Resolution Ultrasound Image Reconstruction
2010-09-01
microcalcifications often occur as one of two types: calcium oxalate dihydrate or calcium hydroxyapatite. Their sizes range approximately from 0.1 mm to 0.5 mm...super-resolution imaging, ultrasound imaging, wave equation. 1. INTRODUCTION Microcalcifications, tiny specks of mineral deposits ( calcium ), are the
Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study
NASA Astrophysics Data System (ADS)
Huang, Lianjie; Labyed, Yassin; Hanson, Kenneth; Sandoval, Daniel; Pohl, Jennifer; Williamson, Michael
2013-03-01
Imaging breast microcalcifications is crucial for early detection and diagnosis of breast cancer. It is challenging for current clinical ultrasound to image breast microcalcifications. However, new imaging techniques using data acquired with a synthetic-aperture ultrasound system have the potential to significantly improve ultrasound imaging. We recently developed a super-resolution ultrasound imaging method termed the phase-coherent multiple-signal classification (PC-MUSIC). This signal subspace method accounts for the phase response of transducer elements to improve image resolution. In this paper, we investigate the clinical feasibility of our super-resolution ultrasound imaging method for detecting breast microcalcifications. We use our custom-built, real-time synthetic-aperture ultrasound system to acquire breast ultrasound data for 40 patients whose mammograms show the presence of breast microcalcifications. We apply our super-resolution ultrasound imaging method to the patient data, and produce clear images of breast calcifications. Our super-resolution ultrasound PC-MUSIC imaging with synthetic-aperture ultrasound data can provide a new imaging modality for detecting breast microcalcifications in clinic without using ionizing radiation.
1995-09-01
employed to classify benign and malignant microcalcifications in the radiographs of pathological specimen. Digital images were acquired by digitizing...associated with benign and malignant processes. The classification of microcalcifications for the diagnosis of breast cancer was achieved at a high level in
Noël, Jean-Christophe; Buxant, Frédéric; Engohan-Aloghe, Corinne
2010-12-01
The entity of pure flat epithelial atypia remains a challenge due to controversy of the surgical management of residual microcalcifications after core needle biopsies. This study aims to assess the morphological data observed in immediate surgical resection specimen of residual microcalcifications after a diagnosis of pure flat epithelial atypia on mammotome core biopsy. Sixty-two mammotome core biopsy with a diagnosis of pure flat epithelial atypia (flat epithelial atypia without associated atypical ductal hyperplasia, in situ and/or invasive carcinoma) were identified. From these 62 cases, 20 presented residual microcalcifications and underwent an immediate surgical excision after mammotome. Of the 20 patients with excised microcalcifications, 8 (40%)cases had residual pure flat epithelial atypia, 4 (20%) cases had atypical ductal hyperplasia, 4 (20%) cases had lobular in situ neoplasia, no lesions were retrieved in 4 (20%) case. None of the patients had either in situ ductal carcinoma and/or invasive carcinoma. Surgical resection of residual microcalcifications after the diagnosis of pure flat epithelial atypia on core needle biopsy remains still a debate. The present study shows no cases of in situ ductal and/or invasive carcinoma on immediate excision of residual microcalcifications after mammotome core biopsies. Copyright © 2009 Elsevier Ltd. All rights reserved.
Dark-field imaging in coronary atherosclerosis.
Hetterich, Holger; Webber, Nicole; Willner, Marian; Herzen, Julia; Birnbacher, Lorenz; Auweter, Sigrid; Schüller, Ulrich; Bamberg, Fabian; Notohamiprodjo, Susan; Bartsch, Harald; Wolf, Johannes; Marschner, Mathias; Pfeiffer, Franz; Reiser, Maximilian; Saam, Tobias
2017-09-01
Dark-field imaging based on small angle X-ray scattering has been shown to be highly sensitive for microcalcifications, e.g. in breast tissue. We hypothesized (i) that high signal areas in dark-field imaging of atherosclerotic plaque are associated with microcalcifications and (ii) that dark-field imaging is more sensitive for microcalcifications than attenuation-based imaging. Fifteen coronary artery specimens were examined at an experimental set-up consisting of X-ray tube (40kV), grating-interferometer and detector. Tomographic dark-field-, attenuation-, and phase-contrast data were simultaneously acquired. Histopathology served as standard of reference. To explore the potential of dark field imaging in a full-body CT system, simulations were carried out with spherical calcifications of different sizes to simulate small and intermediate microcalcifications. Microcalcifications were present in 10/10 (100%) cross-sections with high dark-field signal and without evidence of calcifications in attenuation- or phase contrast. In positive controls with high signal areas in all three modalities, 10/10 (100%) cross-sections showed macrocalcifications. In negative controls without high signal areas, no calcifications were detected. Simulations showed that the microcalcifications generate substantially higher dark-field than attenuation signal. Dark-field imaging is highly sensitive for microcalcifications in coronary atherosclerotic plaque and might provide complementary information in the assessment of plaque instability. Copyright © 2017 Elsevier B.V. All rights reserved.
Hahn, Soo Yeon; Shin, Jung Hee; Han, Boo-Kyung; Ko, Eun Young
2011-02-01
Management of suspicious microcalcifications in very thin breasts is problematic. To evaluate whether sonographically-guided vacuum-assisted biopsy (USVAB) with digital mammography-guided skin marking (DM) for the diagnosis of breast microcalcifications is comparable to stereotactic-guided vacuum-assisted biopsy (SVAB) in Asian women with thin breasts. Retrospective review was performed for 263 consecutive suspicious microcalcification lesions in 261 women who underwent USVAB with DM or SVAB using a prone table between January 2004 and December 2007. SVAB was performed for 190 lesions and USVAB for 73 lesions. Biopsy results were correlated with surgical pathology or followed up for at least 12 months. The diagnostic outcomes of SVAB and USVAB to diagnose microcalcifications were compared. Of 263 lesions, 104 (40%) underwent surgery and 159 (60%) were followed up. SVAB and USVAB groups showed similar final categories or the extent of microcalcifications. US visible lesions were 57 (78%) of 73 at USVAB and 14 (10%) of 140 at SVAB. Of 57 US visible lesions at USVAB, 29 (51%) were not found in initial US but were detectable with the help of DM. Specimen radiographs were negative in 2.1% of lesions at SVAB and in 4.1% at USVAB (p=0.4008). The under-estimation rate and false-negative rate were similar in SVAB and USVAB. US with DM facilitates US visibility of microcalcifications. USVAB with DM can produce acceptable biopsy results, as can SVAB, to diagnose breast microcalcifications in patients with thin breasts.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84-12.82). DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers.
NASA Astrophysics Data System (ADS)
Lo, Joseph Y.; Gavrielides, Marios A.; Markey, Mia K.; Jesneck, Jonathan L.
2003-05-01
We developed an ensemble classifier for the task of computer-aided diagnosis of breast microcalcification clusters,which are very challenging to characterize for radiologists and computer models alike. The purpose of this study is to help radiologists identify whether suspicious calcification clusters are benign vs. malignant, such that they may potentially recommend fewer unnecessary biopsies for actually benign lesions. The data consists of mammographic features extracted by automated image processing algorithms as well as manually interpreted by radiologists according to a standardized lexicon. We used 292 cases from a publicly available mammography database. From each cases, we extracted 22 image processing features pertaining to lesion morphology, 5 radiologist features also pertaining to morphology, and the patient age. Linear discriminant analysis (LDA) models were designed using each of the three data types. Each local model performed poorly; the best was one based upon image processing features which yielded ROC area index AZ of 0.59 +/- 0.03 and partial AZ above 90% sensitivity of 0.08 +/- 0.03. We then developed ensemble models using different combinations of those data types, and these models all improved performance compared to the local models. The final ensemble model was based upon 5 features selected by stepwise LDA from all 28 available features. This ensemble performed with AZ of 0.69 +/- 0.03 and partial AZ of 0.21 +/- 0.04, which was statistically significantly better than the model based on the image processing features alone (p<0.001 and p=0.01 for full and partial AZ respectively). This demonstrated the value of the radiologist-extracted features as a source of information for this task. It also suggested there is potential for improved performance using this ensemble classifier approach to combine different sources of currently available data.
A Multi-Scale Study on the Role of Trace Metals on Physiological and Pathological Mineralization
NASA Astrophysics Data System (ADS)
Rammelkamp, Derek
The work in this thesis provides mulit-scale contributions towards understanding the effects of trace metals on the pathological mineralization process relating to both the development of healthy bone tissue, the diseased state of osteoporosis, and microcalcifications which develop in breast cancers. A protein level study was performed on ECM protein fibronectin, which plays a role in cell adhesion. The protein studies showed zinc interactions with fibronectin and its fragment, anastellin, to influence protein structure. Zinc is also shown to decrease cell migration in vitro, which may be influenced by changes in fibronectin ECM structure. The effects of osteoporosis on micronutrient composition in vivo were examined using the technique of x-ray fluorescence (XRF) in an ovariectomized rat model. Compared to healthy bone, subtle difference are observed in zinc and iron in osteoporotic rat bones, showing micronutrients may play an important role in healthy bone regulation. Effects of micronutrient zinc was used to inhibit microcalcification formation in breast cancers. Microcalcifications have been linked malignancy of breast cancers, but the process of microcalcification formation has yet to be well understood. In this work, exogenous zinc is used to inhibit microcalcification formation, and metastatic potential in both a 2D and 3D spheroid environment. A novel in vitro self-assembled three dimensional multi-cellular tumor spheroid (MCTS) model for the study of breast cancer microcalcifications was developed for this experiment. A MCTS model for studying breast cancer microcalcifications has potential to be used in drug discovery, or for basic research applications studying mechanisms of microcalcification formation, which are still not fully understood. Taken together this study uses a multi-scale approach to gain a better understanding of micronutrients involved in pathological mineralization.
Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-01-01
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93–98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance. PMID:25927331
NASA Astrophysics Data System (ADS)
Sathyavathi, R.; Saha, Anushree; Soares, Jaqueline S.; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-04-01
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.
Sathyavathi, R; Saha, Anushree; Soares, Jaqueline S; Spegazzini, Nicolas; McGee, Sasha; Rao Dasari, Ramachandra; Fitzmaurice, Maryann; Barman, Ishan
2015-04-30
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93-98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.
Malar, E; Kandaswamy, A; Chakravarthy, D; Giri Dharan, A
2012-09-01
The objective of this paper is to reveal the effectiveness of wavelet based tissue texture analysis for microcalcification detection in digitized mammograms using Extreme Learning Machine (ELM). Microcalcifications are tiny deposits of calcium in the breast tissue which are potential indicators for early detection of breast cancer. The dense nature of the breast tissue and the poor contrast of the mammogram image prohibit the effectiveness in identifying microcalcifications. Hence, a new approach to discriminate the microcalcifications from the normal tissue is done using wavelet features and is compared with different feature vectors extracted using Gray Level Spatial Dependence Matrix (GLSDM) and Gabor filter based techniques. A total of 120 Region of Interests (ROIs) extracted from 55 mammogram images of mini-Mias database, including normal and microcalcification images are used in the current research. The network is trained with the above mentioned features and the results denote that ELM produces relatively better classification accuracy (94%) with a significant reduction in training time than the other artificial neural networks like Bayesnet classifier, Naivebayes classifier, and Support Vector Machine. ELM also avoids problems like local minima, improper learning rate, and over fitting. Copyright © 2012 Elsevier Ltd. All rights reserved.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh
2016-01-01
Background Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). Patients and Methods With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. Results A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84–12.82). Conclusion DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the diagnosis of cancers or lack of enhancement virtually diagnostic for non-malignant lesions or noninvasive subgroup cancers. PMID:27611215
High-frequency ultrasound imaging for breast cancer biopsy guidance
Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.
2015-01-01
Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167
High-resolution computed tomography of single breast cancer microcalcifications in vivo.
Inoue, Kazumasa; Liu, Fangbing; Hoppin, Jack; Lunsford, Elaine P; Lackas, Christian; Hesterman, Jacob; Lenkinski, Robert E; Fujii, Hirofumi; Frangioni, John V
2011-08-01
Microcalcification is a hallmark of breast cancer and a key diagnostic feature for mammography. We recently described the first robust animal model of breast cancer microcalcification. In this study, we hypothesized that high-resolution computed tomography (CT) could potentially detect the genesis of a single microcalcification in vivo and quantify its growth over time. Using a commercial CT scanner, we systematically optimized acquisition and reconstruction parameters. Two ray-tracing image reconstruction algorithms were tested: a voxel-driven "fast" cone beam algorithm (FCBA) and a detector-driven "exact" cone beam algorithm (ECBA). By optimizing acquisition and reconstruction parameters, we were able to achieve a resolution of 104 μm full width at half-maximum (FWHM). At an optimal detector sampling frequency, the ECBA provided a 28 μm (21%) FWHM improvement in resolution over the FCBA. In vitro, we were able to image a single 300 μm × 100 μm hydroxyapatite crystal. In a syngeneic rat model of breast cancer, we were able to detect the genesis of a single microcalcification in vivo and follow its growth longitudinally over weeks. Taken together, this study provides an in vivo "gold standard" for the development of calcification-specific contrast agents and a model system for studying the mechanism of breast cancer microcalcification.
Luk, Yiu Shiobhon; Ka, Solomon Yig Joon; Lo, Sherwin Shing Wai; Chu, Chi Yeung; Ma, Ming Wai
2012-09-01
Breast metastasis from gastric carcinoma is rare. We present a case of right breast mass with microcalcification in which the diagnosis of poorly differentiated adenocarcinoma from the stomach was made after a biopsy. Pleomorphic microcalcification was noted in the ill-defined breast mass, which is a rare feature in breast metastasis. Since breast metastasis usually signifies advanced metastatic disease, differentiating primary breast cancer from metastasis is important for appropriate treatment.
Computer-aided diagnosis of breast microcalcifications based on dual-tree complex wavelet transform.
Jian, Wushuai; Sun, Xueyan; Luo, Shuqian
2012-12-19
Digital mammography is the most reliable imaging modality for breast carcinoma diagnosis and breast micro-calcifications is regarded as one of the most important signs on imaging diagnosis. In this paper, a computer-aided diagnosis (CAD) system is presented for breast micro-calcifications based on dual-tree complex wavelet transform (DT-CWT) to facilitate radiologists like double reading. Firstly, 25 abnormal ROIs were extracted according to the center and diameter of the lesions manually and 25 normal ROIs were selected randomly. Then micro-calcifications were segmented by combining space and frequency domain techniques. We extracted three texture features based on wavelet (Haar, DB4, DT-CWT) transform. Totally 14 descriptors were introduced to define the characteristics of the suspicious micro-calcifications. Principal Component Analysis (PCA) was used to transform these descriptors to a compact and efficient vector expression. Support Vector Machine (SVM) classifier was used to classify potential micro-calcifications. Finally, we used the receiver operating characteristic (ROC) curve and free-response operating characteristic (FROC) curve to evaluate the performance of the CAD system. The results of SVM classifications based on different wavelets shows DT-CWT has a better performance. Compared with other results, DT-CWT method achieved an accuracy of 96% and 100% for the classification of normal and abnormal ROIs, and the classification of benign and malignant micro-calcifications respectively. In FROC analysis, our CAD system for clinical dataset detection achieved a sensitivity of 83.5% at a false positive per image of 1.85. Compared with general wavelets, DT-CWT could describe the features more effectively, and our CAD system had a competitive performance.
Computer-aided diagnosis of breast microcalcifications based on dual-tree complex wavelet transform
2012-01-01
Background Digital mammography is the most reliable imaging modality for breast carcinoma diagnosis and breast micro-calcifications is regarded as one of the most important signs on imaging diagnosis. In this paper, a computer-aided diagnosis (CAD) system is presented for breast micro-calcifications based on dual-tree complex wavelet transform (DT-CWT) to facilitate radiologists like double reading. Methods Firstly, 25 abnormal ROIs were extracted according to the center and diameter of the lesions manually and 25 normal ROIs were selected randomly. Then micro-calcifications were segmented by combining space and frequency domain techniques. We extracted three texture features based on wavelet (Haar, DB4, DT-CWT) transform. Totally 14 descriptors were introduced to define the characteristics of the suspicious micro-calcifications. Principal Component Analysis (PCA) was used to transform these descriptors to a compact and efficient vector expression. Support Vector Machine (SVM) classifier was used to classify potential micro-calcifications. Finally, we used the receiver operating characteristic (ROC) curve and free-response operating characteristic (FROC) curve to evaluate the performance of the CAD system. Results The results of SVM classifications based on different wavelets shows DT-CWT has a better performance. Compared with other results, DT-CWT method achieved an accuracy of 96% and 100% for the classification of normal and abnormal ROIs, and the classification of benign and malignant micro-calcifications respectively. In FROC analysis, our CAD system for clinical dataset detection achieved a sensitivity of 83.5% at a false positive per image of 1.85. Conclusions Compared with general wavelets, DT-CWT could describe the features more effectively, and our CAD system had a competitive performance. PMID:23253202
Jothilakshmi, G R; Raaza, Arun; Rajendran, V; Sreenivasa Varma, Y; Guru Nirmal Raj, R
2018-06-05
Breast cancer is one of the life-threatening cancers occurring in women. In recent years, from the surveys provided by various medical organizations, it has become clear that the mortality rate of females is increasing owing to the late detection of breast cancer. Therefore, an automated algorithm is needed to identify the early occurrence of microcalcification, which would assist radiologists and physicians in reducing the false predictions via image processing techniques. In this work, we propose a new algorithm to detect the pattern of a microcalcification by calculating its physical characteristics. The considered physical characteristics are the reflection coefficient and mass density of the binned digital mammogram image. The calculation of physical characteristics doubly confirms the presence of malignant microcalcification. Subsequently, by interpolating the physical characteristics via thresholding and mapping techniques, a three-dimensional (3D) projection of the region of interest (RoI) is obtained in terms of the distance in millimeter. The size of a microcalcification is determined using this 3D-projected view. This algorithm is verified with 100 abnormal mammogram images showing microcalcification and 10 normal mammogram images. In addition to the size calculation, the proposed algorithm acts as a good classifier that is used to classify the considered input image as normal or abnormal with the help of only two physical characteristics. This proposed algorithm exhibits a classification accuracy of 99%.
Maetzler, Walter; Berg, Daniela; Funke, Claudia; Sandmann, Freya; Stünitz, Holger; Maetzler, Corina; Nitsch, Cordula
2010-01-01
In the brain, osteopontin (OPN) may function in a variety of pathological conditions, including neurodegeneration, microcalcification, and inflammation. In this study, we addressed the role of OPN in primary and secondary neurodegeneration, microcalcification, and inflammation after an excitotoxic lesion by examining OPN knock-out (KO) mice. Two, four, and ten weeks after injection of the glutamate analogue ibotenate into the corticostriatal boundary, the brains of 12 mice per survival time and strain were evaluated. OPN was detectable in neuron-shaped cells, in microglia, and at the surface of dense calcium deposits. At this primary lesion site, although the glial reaction was attenuated in OPN-KO mice, lesion size and presence of microcalcification were comparable between OPN-KO and wild-type mice. In contrast, secondary neurodegeneration at the thalamus was more prominent in OPN-KO mice, and this difference increased over time. This was paralleled by a dramatic rise in the regional extent of dense microcalcification. Despite these differences, the numbers of glial cells did not significantly differ between the two strains. This study demonstrates for the first time a genetic model with co-occurrence of neurodegeneration and microcalcification, mediated by the lack of OPN, and suggests a basic involvement of OPN action in these conditions. In the case of secondary retrograde or transneuronal degeneration, OPN may have a protective role as intracellular actor. PMID:20522649
Digital Image Processing Technique for Breast Cancer Detection
NASA Astrophysics Data System (ADS)
Guzmán-Cabrera, R.; Guzmán-Sepúlveda, J. R.; Torres-Cisneros, M.; May-Arrioja, D. A.; Ruiz-Pinales, J.; Ibarra-Manzano, O. G.; Aviña-Cervantes, G.; Parada, A. González
2013-09-01
Breast cancer is the most common cause of death in women and the second leading cause of cancer deaths worldwide. Primary prevention in the early stages of the disease becomes complex as the causes remain almost unknown. However, some typical signatures of this disease, such as masses and microcalcifications appearing on mammograms, can be used to improve early diagnostic techniques, which is critical for women’s quality of life. X-ray mammography is the main test used for screening and early diagnosis, and its analysis and processing are the keys to improving breast cancer prognosis. As masses and benign glandular tissue typically appear with low contrast and often very blurred, several computer-aided diagnosis schemes have been developed to support radiologists and internists in their diagnosis. In this article, an approach is proposed to effectively analyze digital mammograms based on texture segmentation for the detection of early stage tumors. The proposed algorithm was tested over several images taken from the digital database for screening mammography for cancer research and diagnosis, and it was found to be absolutely suitable to distinguish masses and microcalcifications from the background tissue using morphological operators and then extract them through machine learning techniques and a clustering algorithm for intensity-based segmentation.
Region-growing approach to detect microcalcifications in digital mammograms
NASA Astrophysics Data System (ADS)
Shin, Jin-Wook; Chae, Soo-Ik; Sook, Yoon M.; Park, Dong-Sun
2001-09-01
Detecting early symptoms of breast cancer is very important to enhance the possibility of cure. There have been active researches to develop computer-aided diagnosis(CAD) systems detecting early symptoms of breast cancer in digital mammograms. An expert or a CAD system can recognize the early symptoms based on microcalcifications appeared in digital mammographic images. Microcalcifications have higher gray value than surrounding regions, so these can be detected by expanding a region from a local maximum. However the resultant image contains unnecessary elements such as noise, holes and valleys. Mathematical morphology is a good solution to delete regions that are affected by the unnecessary elements. In this paper, we present a method that effectively detects microcalcifications in digital mammograms using a combination of local maximum operation and the region-growing operation.
Aortic microcalcification is associated with elastin fragmentation in Marfan syndrome.
Wanga, Shaynah; Hibender, Stijntje; Ridwan, Yanto; van Roomen, Cindy; Vos, Mariska; van der Made, Ingeborg; van Vliet, Nicole; Franken, Romy; van Riel, Luigi Amjg; Groenink, Maarten; Zwinderman, Aeilko H; Mulder, Barbara Jm; de Vries, Carlie Jm; Essers, Jeroen; de Waard, Vivian
2017-11-01
Marfan syndrome (MFS) is a connective tissue disorder in which aortic rupture is the major cause of death. MFS patients with an aortic diameter below the advised limit for prophylactic surgery (<5 cm) may unexpectedly experience an aortic dissection or rupture, despite yearly monitoring. Hence, there is a clear need for improved prognostic markers to predict such aortic events. We hypothesize that elastin fragments play a causal role in aortic calcification in MFS, and that microcalcification serves as a marker for aortic disease severity. To address this hypothesis, we analysed MFS patient and mouse aortas. MFS patient aortic tissue showed enhanced microcalcification in areas with extensive elastic lamina fragmentation in the media. A causal relationship between medial injury and microcalcification was revealed by studies in vascular smooth muscle cells (SMCs); elastin peptides were shown to increase the activity of the calcification marker alkaline phosphatase (ALP) and reduce the expression of the calcification inhibitor matrix GLA protein in human SMCs. In murine Fbn1 C1039G/+ MFS aortic SMCs, Alpl mRNA and activity were upregulated as compared with wild-type SMCs. The elastin peptide-induced ALP activity was prevented by incubation with lactose or a neuraminidase inhibitor, which inhibit the elastin receptor complex, and a mitogen-activated protein kinase kinase-1/2 inhibitor, indicating downstream involvement of extracellular signal-regulated kinase-1/2 (ERK1/2) phosphorylation. Histological analyses in MFS mice revealed macrocalcification in the aortic root, whereas the ascending aorta contained microcalcification, as identified with the near-infrared fluorescent bisphosphonate probe OsteoSense-800. Significantly, microcalcification correlated strongly with aortic diameter, distensibility, elastin breaks, and phosphorylated ERK1/2. In conclusion, microcalcification co-localizes with aortic elastin degradation in MFS aortas of humans and mice, where elastin-derived peptides induce a calcification process in SMCs via the elastin receptor complex and ERK1/2 activation. We propose microcalcification as a novel imaging marker to monitor local elastin degradation and thus predict aortic events in MFS patients. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.
2016-10-27
AFRL-AFOSR-UK-TR-2016-0037 Towards cluster-assembled materials of true monodispersity in size and chemical environment: Synthesis, Dynamics and...Towards cluster-assembled materials of true monodispersity in size and chemical environment: synthesis, dynamics and activity 5a. CONTRACT NUMBER 5b...report Towards cluster-assembled materials of true monodispersity in size and chemical environment: Synthesis, Dynamics and Activity Ulrich Heiz
Automated System for Early Breast Cancer Detection in Mammograms
NASA Technical Reports Server (NTRS)
Bankman, Isaac N.; Kim, Dong W.; Christens-Barry, William A.; Weinberg, Irving N.; Gatewood, Olga B.; Brody, William R.
1993-01-01
The increasing demand on mammographic screening for early breast cancer detection, and the subtlety of early breast cancer signs on mammograms, suggest an automated image processing system that can serve as a diagnostic aid in radiology clinics. We present a fully automated algorithm for detecting clusters of microcalcifications that are the most common signs of early, potentially curable breast cancer. By using the contour map of the mammogram, the algorithm circumvents some of the difficulties encountered with standard image processing methods. The clinical implementation of an automated instrument based on this algorithm is also discussed.
Visualization of microcalcifications using photoacoustic imaging: feasibility study
NASA Astrophysics Data System (ADS)
Hsiao, Tsai-Chu; Wang, Po-Hsun; Fan, Chih-Tai; Cheng, Yao-You; Li, Meng-Lin
2011-03-01
Recently, photoacoustic imaging has been intensively studied for blood vessel imaging, and shown its capability of revealing vascular features suggestive of malignancy of breast cancer. In this study, we explore the feasibility of visualization of micro-calcifications using photoacoustic imaging. Breast micro-calcification is also known as one of the most important indicators for early breast cancer detection. The non-ionizing radiation and speckle free nature of photoacoustic imaging overcomes the drawbacks of current diagnostic tools - X-ray mammography and ultrasound imaging, respectively. We employed a 10-MHz photoacoustic imaging system to verify our idea. A sliced chicken breast phantom with granulated calcium hydroxyapatite (HA) - major chemical composition of the breast calcification associated with malignant breast cancers - embedded was imaged. With the near infared (NIR) laser excitation, it is shown that the distribution of ~500 μm HAs can be clearly imaged. In addition, photoacoustic signals from HAs rivals those of blood given an optimal NIR wavelength. In summary, photoacoustic imaging shows its promise for breast micro-calcification detection. Moreover, fusion of the photoacoustic and ultrasound images can reveal the location and distribution of micro-calcifications within anatomical landmarks of the breast tissue, which is clinically useful for biopsy and diagnosis of breast cancer staging.
Stats, Miriam A; Stone, James R
2016-01-01
Recently, there has been much interest in using nuclear medicine studies to noninvasively identify and subtype cardiac amyloidosis. In particular, modified bone scans using (99m)Tc-3,3-diphosphono-1,2-propanodicarboxylic acid ((99m)Tc-DPD) and (99m)Tc-pyrophosphate ((99m)Tc-PYP) are being used to selectively identify patients with ATTR amyloidosis rather than AL amyloidosis. The morphologic basis underlying the selectivity of these imaging modalities for ATTR amyloidosis has been unclear. To determine if variations in microcalcifications and/or macrophages within ATTR and AL amyloidosis might be responsible for the selectivity for these imaging modalities, 8 endomyocardial biopsies of ATTR amyloidosis and 7 endomyocardial biopsies of AL amyloidosis were stained with von Kossa calcium stains and with immunohistochemistry for the macrophage marker CD68. Compared with AL amyloidosis, there was a greater density of small microcalcifications in cases of ATTR amyloidosis (mean=16.8 vs. 6.5 per 200× field, P=.008). In contrast, there were fewer macrophages in ATTR amyloidosis compared with AL amyloidosis (mean=2.5 vs. 11.7 per 200× field, P=.0004). The density of microcalcifications within each group was not related to patient age, echocardiographic features of cardiac function, or serum levels of calcium and creatinine. These data suggest that microcalcifications but not macrophages likely underlie the selectivity of modified bone scans for ATTR amyloidosis and suggest that other pathologic entities containing microcalcifications might also result in positive scans with these imaging modalities. Copyright © 2016 Elsevier Inc. All rights reserved.
Locally adaptive decision in detection of clustered microcalcifications in mammograms.
Sainz de Cea, María V; Nishikawa, Robert M; Yang, Yongyi
2018-02-15
In computer-aided detection or diagnosis of clustered microcalcifications (MCs) in mammograms, the performance often suffers from not only the presence of false positives (FPs) among the detected individual MCs but also large variability in detection accuracy among different cases. To address this issue, we investigate a locally adaptive decision scheme in MC detection by exploiting the noise characteristics in a lesion area. Instead of developing a new MC detector, we propose a decision scheme on how to best decide whether a detected object is an MC or not in the detector output. We formulate the individual MCs as statistical outliers compared to the many noisy detections in a lesion area so as to account for the local image characteristics. To identify the MCs, we first consider a parametric method for outlier detection, the Mahalanobis distance detector, which is based on a multi-dimensional Gaussian distribution on the noisy detections. We also consider a non-parametric method which is based on a stochastic neighbor graph model of the detected objects. We demonstrated the proposed decision approach with two existing MC detectors on a set of 188 full-field digital mammograms (95 cases). The results, evaluated using free response operating characteristic (FROC) analysis, showed a significant improvement in detection accuracy by the proposed outlier decision approach over traditional thresholding (the partial area under the FROC curve increased from 3.95 to 4.25, p-value <10 -4 ). There was also a reduction in case-to-case variability in detected FPs at a given sensitivity level. The proposed adaptive decision approach could not only reduce the number of FPs in detected MCs but also improve case-to-case consistency in detection.
Flat epithelial atypia of the breast: pathological-radiological correlation.
Solorzano, Silma; Mesurolle, Benoît; Omeroglu, Attila; El Khoury, Mona; Kao, Ellen; Aldis, Ann; Meterissian, Sarkis
2011-09-01
This study was undertaken to determine the prevalence of flat epithelial atypia at ultrasound-guided and stereotactically guided needle biopsies, to describe the mammographic and sonographic features of flat epithelial atypia, and to determine the significance of lesions diagnosed as flat epithelial atypia at imaging-guided needle biopsies. Retrospective review of a database of 1369 consecutive sonographically and stereotactically guided needle biopsies performed during a 12-month period yielded 33 lesions with flat epithelial atypia as the most severe pathologic entity (32 patients). Two radiologists retrospectively reviewed the imaging presentation, by combined consensus, according to the BI-RADS lexicon. Twenty-two of 33 flat epithelial atypia diagnoses (67%) were obtained under stereotactic guidance, and 11 (33%) were obtained under sonographic guidance. Six patients had synchronous breast cancer. Flat epithelial atypia lesions presented mammographically most often as microcalcifications (20/33 [61%]) distributed in a cluster (14/20 [70%]) with amorphous morphology (13/20 [65%]). Sonographically, flat epithelial atypia lesions appeared most often as masses (9/11 [82%]), with an irregular shape (6/9 [67%]), microlobulated margins (5/9 [56%]), and hypoechoic or complex echotexture (7/9 [78%]). Twenty-eight of 33 lesions (85%) were surgically excised, confirming the flat epithelial atypia diagnosis in 11 of the 28 lesions (39%), yielding carcinoma in four (14%) and atypical ductal hyperplasia in six (21%). Columnar cell changes without atypia were diagnosed in four lesions (14%), and lobular carcinoma in situ was diagnosed in three lesions (11%). Mammographic and sonographic presentation of flat epithelial atypia is not specific (clustered amorphous microcalcifications and irregular, hypoechoic or complex masses). Given the underestimation rate of malignancy, surgical excision should be considered when imaging-guided biopsy yields flat epithelial atypia.
NASA Astrophysics Data System (ADS)
Khehra, Baljit Singh; Pharwaha, Amar Partap Singh
2017-04-01
Ductal carcinoma in situ (DCIS) is one type of breast cancer. Clusters of microcalcifications (MCCs) are symptoms of DCIS that are recognized by mammography. Selection of robust features vector is the process of selecting an optimal subset of features from a large number of available features in a given problem domain after the feature extraction and before any classification scheme. Feature selection reduces the feature space that improves the performance of classifier and decreases the computational burden imposed by using many features on classifier. Selection of an optimal subset of features from a large number of available features in a given problem domain is a difficult search problem. For n features, the total numbers of possible subsets of features are 2n. Thus, selection of an optimal subset of features problem belongs to the category of NP-hard problems. In this paper, an attempt is made to find the optimal subset of MCCs features from all possible subsets of features using genetic algorithm (GA), particle swarm optimization (PSO) and biogeography-based optimization (BBO). For simulation, a total of 380 benign and malignant MCCs samples have been selected from mammogram images of DDSM database. A total of 50 features extracted from benign and malignant MCCs samples are used in this study. In these algorithms, fitness function is correct classification rate of classifier. Support vector machine is used as a classifier. From experimental results, it is also observed that the performance of PSO-based and BBO-based algorithms to select an optimal subset of features for classifying MCCs as benign or malignant is better as compared to GA-based algorithm.
Locally adaptive decision in detection of clustered microcalcifications in mammograms
NASA Astrophysics Data System (ADS)
Sainz de Cea, María V.; Nishikawa, Robert M.; Yang, Yongyi
2018-02-01
In computer-aided detection or diagnosis of clustered microcalcifications (MCs) in mammograms, the performance often suffers from not only the presence of false positives (FPs) among the detected individual MCs but also large variability in detection accuracy among different cases. To address this issue, we investigate a locally adaptive decision scheme in MC detection by exploiting the noise characteristics in a lesion area. Instead of developing a new MC detector, we propose a decision scheme on how to best decide whether a detected object is an MC or not in the detector output. We formulate the individual MCs as statistical outliers compared to the many noisy detections in a lesion area so as to account for the local image characteristics. To identify the MCs, we first consider a parametric method for outlier detection, the Mahalanobis distance detector, which is based on a multi-dimensional Gaussian distribution on the noisy detections. We also consider a non-parametric method which is based on a stochastic neighbor graph model of the detected objects. We demonstrated the proposed decision approach with two existing MC detectors on a set of 188 full-field digital mammograms (95 cases). The results, evaluated using free response operating characteristic (FROC) analysis, showed a significant improvement in detection accuracy by the proposed outlier decision approach over traditional thresholding (the partial area under the FROC curve increased from 3.95 to 4.25, p-value <10-4). There was also a reduction in case-to-case variability in detected FPs at a given sensitivity level. The proposed adaptive decision approach could not only reduce the number of FPs in detected MCs but also improve case-to-case consistency in detection.
Dual Energy Method for Breast Imaging: A Simulation Study.
Koukou, V; Martini, N; Michail, C; Sotiropoulou, P; Fountzoula, C; Kalyvas, N; Kandarakis, I; Nikiforidis, G; Fountos, G
2015-01-01
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNR tc ) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.
Dual Energy Method for Breast Imaging: A Simulation Study
2015-01-01
Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels. PMID:26246848
Can magnetic resonance imaging obviate the need for biopsy for microcalcifications?
Chishima, Takashi
2017-01-01
Background Although microcalcifications detected with mammography (MG) are usually biopsied, biopsies cannot be performed in all cases. We sought to determine if magnetic resonance imaging (MRI) findings could indicate whether stereotactic vacuum-assisted biopsy (SVAB) is necessary. Methods Patients with mammographically detected Breast Imaging-Reporting and Data System (BI-RADS) 3, 4, and 5 microcalcifications were analyzed from April 2012 to September 2014. All patients underwent MRI. All patients with enhancing lesions in the region of the microcalcifications underwent SVAB. Non-enhancing lesions were followed or biopsied, depending on the patient's preferences. MRI findings were classified as either malignant-suspicious or benign-suspicious (“none” or “nonspecific”), and we evaluated the positive predictive value (PPV) and negative predictive value (NPV) of these classifications for predicting malignancy. Results A total of 87 patients underwent both MRI and SVAB. The NPV of MRI was 100% in the group with no enhancement. In BI-RADS category 3, there were 57 benign-suspicious lesions on MRI, of which eight were malignant (NPV of MRI: 85.0%). Conclusions It may be possible to omit SVAB for microcalcifications if there is no enhancement on MRI; however, any kind of enhancement indicates the need for biopsy in cases of BI-RADS 3 calcifications on MG. PMID:28861368
NASA Astrophysics Data System (ADS)
Del Lama, L. S.; Cunha, D. M.; Poletti, M. E.
2017-08-01
The presence and morphology of microcalcification clusters are the main point to provide early indications of breast carcinomas. However, the visualization of those structures may be jeopardized due to overlapping tissues even for digital mammography systems. Although digital mammography is the current standard for breast cancer diagnosis, further improvements should be achieved in order to address some of those physical limitations. One possible solution for such issues is the application of the dual-energy technique (DE), which is able to highlight specific lesions or cancel out the tissue background. In this sense, this work aimed to evaluate several quantities of interest in radiation applications and compare those values with works present in the literature to validate a modified PENELOPE code for digital mammography applications. For instance, the scatter-to-primary ratio (SPR), the scatter fraction (SF) and the normalized mean glandular dose (DgN) were evaluated by simulations and the resulting values were compared to those found in earlier studies. Our results present a good correlation for the evaluated quantities, showing agreement equal or better than 5% for the scatter and dosimetric-related quantities when compared to the literature. Finally, a DE imaging chain was simulated and the visualization of microcalcifications was investigated.
NASA Astrophysics Data System (ADS)
Chan, Heang-Ping; Helvie, Mark A.; Petrick, Nicholas; Sahiner, Berkman; Adler, Dorit D.; Blane, Caroline E.; Joynt, Lynn K.; Paramagul, Chintana; Roubidoux, Marilyn A.; Wilson, Todd E.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.
1999-05-01
A receiver operating characteristic (ROC) experiment was conducted to evaluate the effects of pixel size on the characterization of mammographic microcalcifications. Digital mammograms were obtained by digitizing screen-film mammograms with a laser film scanner. One hundred twelve two-view mammograms with biopsy-proven microcalcifications were digitized at a pixel size of 35 micrometer X 35 micrometer. A region of interest (ROI) containing the microcalcifications was extracted from each image. ROI images with pixel sizes of 70 micrometers, 105 micrometers, and 140 micrometers were derived from the ROI of 35 micrometer pixel size by averaging 2 X 2, 3 X 3, and 4 X 4 neighboring pixels, respectively. The ROI images were printed on film with a laser imager. Seven MQSA-approved radiologists participated as observers. The likelihood of malignancy of the microcalcifications was rated on a 10-point confidence rating scale and analyzed with ROC methodology. The classification accuracy was quantified by the area, Az, under the ROC curve. The statistical significance of the differences in the Az values for different pixel sizes was estimated with the Dorfman-Berbaum-Metz (DBM) method for multi-reader, multi-case ROC data. It was found that five of the seven radiologists demonstrated a higher classification accuracy with the 70 micrometer or 105 micrometer images. The average Az also showed a higher classification accuracy in the range of 70 to 105 micrometer pixel size. However, the differences in A(subscript z/ between different pixel sizes did not achieve statistical significance. The low specificity of image features of microcalcifications an the large interobserver and intraobserver variabilities may have contributed to the relatively weak dependence of classification accuracy on pixel size.
Sonographic findings of high-grade and non-high-grade ductal carcinoma in situ of the breast.
Park, Ji-Sung; Park, Young-Mi; Kim, Eun-Kyung; Kim, Suk-Jung; Han, Sang-Suk; Lee, Sun-Joo; In, Hyun-Sin; Ryu, Ji-Hwa
2010-12-01
The purpose of this study was to differentiate between high-grade and non-high-grade ductal carcinoma in situ (DCIS) of the breast on sonography. From October 2003 to August 2009, 76 DCIS lesions in 73 women who underwent sonography and mammography were included in this study. Lesions were confirmed by mastectomy, breast-conserving surgery, or surgical biopsy. Images were analyzed by 2 radiologists with consensus and were correlated with histologic grades. Of the 76 lesions, 44 were classified as high--grade and 32 as non-high-grade DCIS. Fifty-seven lesions (75.0%) were identified on sonography, which revealed a mass in 30 cases, microcalcifications in 20, ductal changes in 4, and architectural distortion in 3. All cases with false-negative findings on sonography (n = 19) showed microcalcifications on mammography. On sonography, masses were more frequently found in non-high-grade (62.5%) than high-grade DCIS (22.7%; P < .01). No significant difference was seen in the sonographic features of masses between high-grade and non-high-grade DCIS. Microcalcifications were more common in high-grade (43.2%) than non-high-grade (3.1%) DCIS (P = .02). Most sonographically visible microcalcifications had associated findings such as ductal changes (n = 11), a mass (n = 7), or a hypoechoic area (n = 5). The detection rate of microcalcifications on sonography was higher in high-grade (62.9%) than non-high-grade DCIS (25.0%; P = .023). Microcalcifications with associated ductal changes (11 of 31 [35.5%]) were the most common sonographic findings in high-grade DCIS. An irregular hypoechoic mass with an indistinct and microlobulated margin (13 of 26 [50.0%]) was the most frequent finding in non-high-grade DCIS.
Helal, Maha H; Mansour, Sahar M; Zaglol, Mai; Salaleldin, Lamia A; Nada, Omniya M; Haggag, Marwa A
2017-03-01
To study the role of advanced applications of digital mammogram, whether contrast-enhanced spectral mammography (CESM) or digital breast tomosynthesis (DBT), in the "T" staging of histologically proven breast cancer before planning for treatment management. In this prospective analysis, we evaluated 98 proved malignant breast masses regarding their size, multiplicity and the presence of associated clusters of microcalcifications. Evaluation methods included digital mammography (DM), 3D tomosynthesis and CESM. Traditional DM was first performed then in a period of 10-14-day interval; breast tomosynthesis and contrast-based mammography were performed for the involved breast only. Views at tomosynthesis were acquired in a "step-and-shoot" tube motion mode to produce multiple (11-15), low-dose images and in contrast-enhanced study, low-energy (22-33 kVp) and high-energy (44-49 kVp) exposures were taken after the i.v. injection of the contrast agent. Operative data were the gold standard reference. Breast tomosynthesis showed the highest accuracy in size assessment (n = 69, 70.4%) than contrast-enhanced (n = 49, 50%) and regular mammography (n = 59, 60.2%). Contrast-enhanced mammography presented the least performance in assessing calcifications, yet it was most sensitive in the detection of multiplicity (92.3%), followed by tomosynthesis (77%) and regular mammography (53.8%). The combined analysis of the three modalities provided an accuracy of 74% in the "T" staging of breast cancer. The combined application of tomosynthesis and contrast-enhanced digital mammogram enhanced the performance of the traditional DM and presented an informative method in the staging of breast cancer. Advances in knowledge: Staging and management planning of breast cancer can divert according to tumour size, multiplicity and the presence of microcalcifications. DBT shows sharp outlines of the tumour with no overlap tissue and spots microcalcifications. Contrast-enhanced spectral mammogram shows the extent of abnormal contrast uptake and detects multiplicity. Integrated analysis provides optimal findings for proper "T" staging of breast cancer.
NASA Astrophysics Data System (ADS)
Tseng, Y. P.; Bouzy, P.; Stone, N.; Pedersen, C.; Tidemand-Lichtenberg, P.
2018-02-01
Spectral imaging in the long-wave infrared regime has great potential for medical diagnostics. Breast cancer is the most common cancer amongst females in the US. The pathological features and the occurrence of the microcalcifications are still poorly understood. However, two types of microcalcifications have been identified as unique biomarkers: type I consisting of calcium oxalate (benign lesions) and type II composed of hydroxyapatite (benign or invasive lesions). In this study, we propose a new approach based on vibrational spectroscopy that is non-destructive, label-free and chemically specific for breast cancer detection. Long-wave infrared spectroscopy combining quantum cascade lasers (QCL) and upconversion detection, offer to improve signal-to-noise ratios compared to standard long-wave infrared spectroscopy. We demonstrated long-wave identification of synthetic samples of carbonated hydroxyapatite and of microcalcification in breast cancer tissue using upconversion detection. Absorbance spectra and upconverted images of in situ breast cancer biopsy are compared with that of Fourier-transform infrared (FTIR) spectroscopy.
Cheung, Yun-Chung; Juan, Yu-Hsiang; Ueng, Shir-Hwa; Lo, Yung-Feng; Huang, Pei-Chin; Lin, Yu-Ching; Chen, Shin-Cheh
2015-10-01
Presence of microcalcifications within the specimens frequently signifies a successful attempt of stereotactic vacuum-assisted breast biopsy (VABB) in obtaining a pathologic diagnosis of the breast microcalcifications. In this study, the authors aimed to assess and compare the accuracy and consistency of calcified or noncalcified specimens obtained from same sites of sampling on isolated microcalcifications without mass in diagnosing high-risk and malignant lesions. To the best of our knowledge, an individual case-based prospective comparison has not been reported.With the approval from institutional review board of our hospital (Chang Gung Memorial Hospital), the authors retrospectively reviewed all clinical cases of stereotactic VABBs on isolated breast microcalcifications without mass from our database. The authors included those having either surgery performed or had clinical follow-up of at least 3 years for analysis. All the obtained specimens with or without calcification were identified using specimen radiographs and separately submitted for pathologic evaluation. The concordance of diagnosis was assessed for both atypia and malignant lesions.A total of 390 stereotactic VABB procedures (1206 calcified and 1456 noncalcified specimens) were collected and reviewed. The consistent rates between calcified and noncalcified specimens were low for atypia and malignant microcalcifications (44.44% in flat epithelial atypia, 46.51% in atypical ductal hyperplasia, 55.73% in ductal carcinoma in situ, and 71.42% in invasive ductal carcinoma). The discordance in VABB diagnoses indicated that 41.33% of malignant lesions would be misdiagnosed by noncalcified specimens. Furthermore, calcified specimens showed higher diagnostic accuracy of breast cancer as compared with the noncalcified specimens (91.54 % versus 69.49%, respectively). The evaluation of both noncalcified specimens and calcified specimens did not show improvement of diagnostic accuracy as compared with evaluating calcified specimens alone (91.54% versus 91.54%, respectively).The high prevalence of diagnostic discordance between the calcified and noncalcified specimens indicated the higher value of calcified specimens in diagnosing atypia and malignant microcalcifications. Noncalcified specimens did not provide additional diagnostic benefit from this study. The separation of calcified and noncalcified specimens may facilitate more focused interpretation from pathologists among the large number of specimens.
Baheza, Richard A.; Welch, E. Brian; Gochberg, Daniel F.; Sanders, Melinda; Harvey, Sara; Gore, John C.; Yankeelov, Thomas E.
2015-01-01
Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragments within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm)3 and (0.6 mm)3. In images acquired at 7 T with voxel sizes of (0.2 mm)3–(0.4 mm)3, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm)3–(0.6 mm)3, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance. PMID:25735297
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baheza, Richard A.; Welch, E. Brian; Gochberg, Daniel F.
Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragmentsmore » within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm){sup 3} and (0.6 mm){sup 3}. In images acquired at 7 T with voxel sizes of (0.2 mm){sup 3}–(0.4 mm){sup 3}, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm){sup 3}–(0.6 mm){sup 3}, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance.« less
Seo, Mirinae; Chang, Jung Min; Kim, Won Hwa; Park, In-Ae; Lee, Su Hyun; Cho, Nariya; Moon, Woo Kyung
2013-10-01
The purpose of this study was to evaluate the underestimation rate and predictive factor of underestimation of columnar cell lesions (CCLs) without atypia diagnosed through breast core needle biopsies (CNBs). From January 2007 through December 2011, 141 CCLs without atypia, including columnar cell change and columnar cell hyperplasia, were diagnosed in 138 women by CNB. Excisional (n = 16) or imaging follow-up (n = 125) findings were available in all cases. On a per-lesion basis, the underestimation rate and predictive factor of underestimation were evaluated. Among the 16 surgically excised lesions, there were two malignancies (one ductal carcinoma in situ and one invasive ductal carcinoma) and one lobular carcinoma in situ. Overall, the pooled underestimation rate of malignancy was 1.4% (2/141). With regard to lesion variables, the mean lesion size was significantly larger in the underestimation group of CCLs (p = 0.007). Fine pleomorphic morphology of microcalcifications (p < 0.001), the distribution of the microcalcifications (p = 0.007), BI-RADS final assessment (p = 0.001), and imaging-pathologic correlation (p < 0.001) were significantly associated with underestimation. Multivariate analysis showed that fine pleomorphic morphology of microcalcifications (p < 0.0001) was an independent predictor of underestimation in 58 lesions with microcalcifications on mammography. The overall underestimation rate of malignancy was 1.4%. Imaging follow-up is reasonable for CCLs without atypia at CNB, especially in small lesions with less suspicious imaging findings. Fine pleomorphic microcalcifications and higher BI-RADS category might be helpful in the prediction of underestimation of a high-risk lesion or malignancy.
[Comparative study between film mammography and xeromammography; including specimen radiography].
Maeda, M; Hayakawa, K; Okuno, Y; Torizuka, T; Mitsumori, M; Soga, T; Misaki, T; Dokou, S; Ito, K
1990-10-01
We retrospectively evaluated preoperative film- and xeromammography of 23 cases with breast cancers, and compared with postoperative specimen radiography to assess tumor delineation and microcalcification detectability. In tumor detection and margin delineation, film mammography was superior to xeromammography, and in microcalcification, film mammography was equal to xeromammography. These results had a effect on the diagnosis of breast cancers.
Knox, Mark; O'Brien, Angela; Szabó, Endre; Smith, Clare S; Fenlon, Helen M; McNicholas, Michelle M; Flanagan, Fidelma L
2015-06-01
Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p=.77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p=.02). Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Batchelder, Kendra A; Tanenbaum, Aaron B; Albert, Seth; Guimond, Lyne; Kestener, Pierre; Arneodo, Alain; Khalil, Andre
2014-01-01
The 2D Wavelet-Transform Modulus Maxima (WTMM) method was used to detect microcalcifications (MC) in human breast tissue seen in mammograms and to characterize the fractal geometry of benign and malignant MC clusters. This was done in the context of a preliminary analysis of a small dataset, via a novel way to partition the wavelet-transform space-scale skeleton. For the first time, the estimated 3D fractal structure of a breast lesion was inferred by pairing the information from two separate 2D projected mammographic views of the same breast, i.e. the cranial-caudal (CC) and mediolateral-oblique (MLO) views. As a novelty, we define the "CC-MLO fractal dimension plot", where a "fractal zone" and "Euclidean zones" (non-fractal) are defined. 118 images (59 cases, 25 malignant and 34 benign) obtained from a digital databank of mammograms with known radiologist diagnostics were analyzed to determine which cases would be plotted in the fractal zone and which cases would fall in the Euclidean zones. 92% of malignant breast lesions studied (23 out of 25 cases) were in the fractal zone while 88% of the benign lesions were in the Euclidean zones (30 out of 34 cases). Furthermore, a Bayesian statistical analysis shows that, with 95% credibility, the probability that fractal breast lesions are malignant is between 74% and 98%. Alternatively, with 95% credibility, the probability that Euclidean breast lesions are benign is between 76% and 96%. These results support the notion that the fractal structure of malignant tumors is more likely to be associated with an invasive behavior into the surrounding tissue compared to the less invasive, Euclidean structure of benign tumors. Finally, based on indirect 3D reconstructions from the 2D views, we conjecture that all breast tumors considered in this study, benign and malignant, fractal or Euclidean, restrict their growth to 2-dimensional manifolds within the breast tissue.
Helal, Maha H; Zaglol, Mai; Salaleldin, Lamia A; Nada, Omniya M; Haggag, Marwa A
2017-01-01
Objective: To study the role of advanced applications of digital mammogram, whether contrast-enhanced spectral mammography (CESM) or digital breast tomosynthesis (DBT), in the “T” staging of histologically proven breast cancer before planning for treatment management. Methods: In this prospective analysis, we evaluated 98 proved malignant breast masses regarding their size, multiplicity and the presence of associated clusters of microcalcifications. Evaluation methods included digital mammography (DM), 3D tomosynthesis and CESM. Traditional DM was first performed then in a period of 10–14-day interval; breast tomosynthesis and contrast-based mammography were performed for the involved breast only. Views at tomosynthesis were acquired in a “step-and-shoot” tube motion mode to produce multiple (11–15), low-dose images and in contrast-enhanced study, low-energy (22–33 kVp) and high-energy (44–49 kVp) exposures were taken after the i.v. injection of the contrast agent. Operative data were the gold standard reference. Results: Breast tomosynthesis showed the highest accuracy in size assessment (n = 69, 70.4%) than contrast-enhanced (n = 49, 50%) and regular mammography (n = 59, 60.2%). Contrast-enhanced mammography presented the least performance in assessing calcifications, yet it was most sensitive in the detection of multiplicity (92.3%), followed by tomosynthesis (77%) and regular mammography (53.8%). The combined analysis of the three modalities provided an accuracy of 74% in the “T” staging of breast cancer. Conclusion: The combined application of tomosynthesis and contrast-enhanced digital mammogram enhanced the performance of the traditional DM and presented an informative method in the staging of breast cancer. Advances in knowledge: Staging and management planning of breast cancer can divert according to tumour size, multiplicity and the presence of microcalcifications. DBT shows sharp outlines of the tumour with no overlap tissue and spots microcalcifications. Contrast-enhanced spectral mammogram shows the extent of abnormal contrast uptake and detects multiplicity. Integrated analysis provides optimal findings for proper “T” staging of breast cancer. PMID:28055247
Digital mammography: more microcalcifications, more columnar cell lesions without atypia.
Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J
2011-09-01
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2.6%). In conclusion, since the implementation of full-field digital mammography, more microcalcifications are seen at mammography, more often resulting in core needle biopsies, which especially yields more columnar cell lesions without atypia.
Fotou, Maria; Oikonomou, Vassiliki; Zagouri, Flora; Sergentanis, Theodoros N; Nonni, Afroditi; Athanassiadou, Pauline; Drouveli, Theodora; Atsouris, Efstratios; Kotzia, Evagelia; Zografos, George C
2007-04-03
To evaluate imprint cytology in the context of specimens with microcalcifications derived from Vacuum-Assisted Breast Biopsy (VABB). A total of 93 women with microcalcifications BI-RADS 3 and 4 underwent VABB and imprint samples were examined. VABB was performed on Fischer's table using 11-gauge Mammotome vacuum probes. A mammogram of the cores after the procedure confirmed the excision of microcalcifications. For the application of imprint cytology, the cores with microcalcifications confirmed by mammogram were gently rolled against glass microscope slides and thus imprint smears were made. For rapid preliminary diagnosis Diff-Quick stain, modified Papanicolaou stain and May Grunwald Giemsa were used. Afterwards, the core was dipped into a CytoRich Red Collection fluid for a few seconds in order to obtain samples with the use of the specimen wash. After the completion of cytological procedures, the core was prepared for routine histological study. The pathologist was blind to the preliminary cytological results. The cytological and pathological diagnoses were comparatively evaluated. According to the pathological examination, 73 lesions were benign, 15 lesions were carcinomas (12 ductal carcinomas in situ, 3 invasive ductal carcinomas), and 5 lesions were precursor: 3 cases of atypical ductal hyperplasia (ADH) and 2 cases of lobular neoplasia (LN). The observed sensitivity and specificity of the cytological imprints for cancer were 100% (one-sided, 97.5% CI: 78.2%-100%). Only one case of ADH could be detected by imprint cytology. Neither of the two LN cases was detected by the imprints. The imprints were uninformative in 11 out of 93 cases (11.8%). There was no uninformative case among women with malignancy. Imprint cytology provides a rapid, accurate preliminary diagnosis in a few minutes. This method might contribute to the diagnosis of early breast cancer and possibly attenuates patients' anxiety.
Barreau, Béatrice; de Mascarel, Isabelle; Feuga, Caroline; MacGrogan, Gaétan; Dilhuydy, Marie-Hélène; Picot, Véronique; Dilhuydy, Jean-Marie; de Lara, Christine Tunon; Bussières, Emmanuel; Schreer, I
2005-04-01
We retrospectively analysed mammographies of 909 ductal carcinoma in situ (DCIS) (1980-1999) and compared our results to those of literature. Microcalcifications were present in 75% of the cases, and soft-tissue abnormalities in 27% cases with association with calcifications in 14% of cases. Palpable masses were found in 12% of the cases and nipple discharge was present in 12% of the cases. The radiographic-pathologic correlation allowed to suspect the DCIS "aggressiveness" on radiologic signs. Granular, linear, branching and/or galactophoric topography of the microcalcifications were correlated with necrosis, grade 3, comedocarcinoma type. A number of microcalcifications higher than 20 was correlated with necrosis and grade 3. Mammographic size was correlated to histologic size. Masses were correlated with grade 1. A diagnosis strategy can be proposed with a multidisciplinar approach.
Catteau, Xavier; Simon, Philippe; Noël, Jean-Christophe
2012-04-15
15±30% of malignancies detected through screening programs are ductal carcinoma in situ (DCIS), and the majority of DCIS cases present in the form of mammographic microcalcification. This study was performed in order to determine the value of features in predicting invasive disease in patients with mammographic calcification and to help determine which patients (with, Core Needle Biopsy-diagnosed DCIS) are the most appropriate candidates for Sentinel Lymph Node (SLN) biopsy. The original aspect of this study was to select patients with mammographic microcalcification but without an associated mass. The factor that we identified to be associated with invasive disease at final surgical excision was the presence of necrosis at core histology. SLN biopsy or complete axillary lymph node dissection was performed in 22 (40%) patients of whom only one (4.5%) had a micrometastasis. Further larger studies are needed to see if it would be interesting to propose a SLN biopsy in case of necrosis on CNB-diagnosed DCIS with microcalcifications but not associated with a mass. Copyright © 2012 Elsevier GmbH. All rights reserved.
Gürün, O O; Fatouros, P P; Kuhn, G M; de Paredes, E S
2001-04-01
We report on some extensions and further developments of a well-known microcalcification detection algorithm based on adaptive noise equalization. Tissue equivalent phantom images with and without labeled microcalcifications were subjected to this algorithm, and analyses of results revealed some shortcomings in the approach. Particularly, it was observed that the method of estimating the width of distributions in the feature space was based on assumptions which resulted in the loss of similarity preservation characteristics. A modification involving a change of estimator statistic was made, and the modified approach was tested on the same phantom images. Other modifications for improving detectability such as downsampling and use of alternate local contrast filters were also tested. The results indicate that these modifications yield improvements in detectability, while extending the generality of the approach. Extensions to real mammograms and further directions of research are discussed.
Genesis and growth of extracellular vesicle-derived microcalcification in atherosclerotic plaques
Hutcheson, Joshua D.; Goettsch, Claudia; Bertazzo, Sergio; Maldonado, Natalia; Ruiz, Jessica L.; Goh, Wilson; Yabusaki, Katsumi; Faits, Tyler; Bouten, Carlijn; Franck, Gregory; Quillard, Thibaut; Libby, Peter; Aikawa, Masanori; Weinbaum, Sheldon; Aikawa, Elena
2015-01-01
Clinical evidence links arterial calcification and cardiovascular risk. Finite-element modelling of the stress distribution within atherosclerotic plaques has suggested that subcellular microcalcifications in the fibrous cap may promote material failure of the plaque, but that large calcifications can stabilize it. Yet the physicochemical mechanisms underlying such mineral formation and growth in atheromata remain unknown. Here, by using three-dimensional collagen hydrogels that mimic structural features of the atherosclerotic fibrous cap, and high-resolution microscopic and spectroscopic analyses of both the hydrogels and of calcified human plaques, we demonstrate that calcific mineral formation and maturation results from a series of events involving the aggregation of calcifying extracellular vesicles, and the formation of microcalcifications and ultimately large calcification zones. We also show that calcification morphology and the plaque’s collagen content – two determinants of atherosclerotic plaque stability - are interlinked. PMID:26752654
D3D augmented reality imaging system: proof of concept in mammography.
Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene
2016-01-01
The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.
Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico
2016-04-01
In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.
Michielsen, Koen; Nuyts, Johan; Cockmartin, Lesley; Marshall, Nicholas; Bosmans, Hilde
2016-12-01
In this work, the authors design and validate a model observer that can detect groups of microcalcifications in a four-alternative forced choice experiment and use it to optimize a smoothing prior for detectability of microcalcifications. A channelized Hotelling observer (CHO) with eight Laguerre-Gauss channels was designed to detect groups of five microcalcifications in a background of acrylic spheres by adding the CHO log-likelihood ratios calculated at the expected locations of the five calcifications. This model observer is then applied to optimize the detectability of the microcalcifications as a function of the smoothing prior. The authors examine the quadratic and total variation (TV) priors, and a combination of both. A selection of these reconstructions was then evaluated by human observers to validate the correct working of the model observer. The authors found a clear maximum for the detectability of microcalcification when using the total variation prior with weight β TV = 35. Detectability only varied over a small range for the quadratic and combined quadratic-TV priors when weight β Q of the quadratic prior was changed by two orders of magnitude. Spearman correlation with human observers was good except for the highest value of β for the quadratic and TV priors. Excluding those, the authors found ρ = 0.93 when comparing detection fractions, and ρ = 0.86 for the fitted detection threshold diameter. The authors successfully designed a model observer that was able to predict human performance over a large range of settings of the smoothing prior, except for the highest values of β which were outside the useful range for good image quality. Since detectability only depends weakly on the strength of the combined prior, it is not possible to pick an optimal smoothness based only on this criterion. On the other hand, such choice can now be made based on other criteria without worrying about calcification detectability.
Ahrens, Bradley J; Li, Lin; Ciminera, Alexandra K; Chea, Junie; Poku, Erasmus; Bading, James R; Weist, Michael R; Miller, Marcia M; Colcher, David M; Shively, John E
2017-09-01
The development of improved breast cancer screening methods is hindered by a lack of cancer-specific imaging agents and effective small-animal models to test them. The purpose of this study was to evaluate 64 Cu-DOTA-alendronate as a mammary microcalcification-targeting PET imaging agent, using an ideal rat model. Our long-term goal is to develop 64 Cu-DOTA-alendronate for the detection and noninvasive differentiation of malignant versus benign breast tumors with PET. Methods: DOTA-alendronate was synthesized, radiolabeled with 64 Cu, and administered to normal or tumor-bearing aged, female, retired breeder Sprague-Dawley rats for PET imaging. Mammary tissues were subsequently labeled and imaged with light, confocal, and electron microscopy to verify microcalcification targeting specificity of DOTA-alendronate and elucidate the histologic and ultrastructural characteristics of the microcalcifications in different mammary tumor types. Tumor uptake, biodistribution, and dosimetry studies were performed to evaluate the efficacy and safety of 64 Cu-DOTA-alendronate. Results: 64 Cu-DOTA-alendronate was radiolabeled with a 98% yield. PET imaging using aged, female, retired breeder rats showed specific binding of 64 Cu-DOTA-alendronate in mammary glands and mammary tumors. The highest uptake of 64 Cu-DOTA-alendronate was in malignant tumors and the lowest uptake in benign tumors and normal mammary tissue. Confocal analysis with carboxyfluorescein-alendronate confirmed the microcalcification binding specificity of alendronate derivatives. Biodistribution studies revealed tissue alendronate concentrations peaking within the first hour, then decreasing over the next 48 h. Our dosimetric analysis demonstrated a 64 Cu effective dose within the acceptable range for clinical PET imaging agents and the potential for translation into human patients. Conclusion: 64 Cu-DOTA-alendronate is a promising PET imaging agent for the sensitive and specific detection of mammary tumors as well as the differentiation of malignant versus benign tumors based on absolute labeling uptake. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Ahrens, Bradley J.; Li, Lin; Ciminera, Alexandra K.; Chea, Junie; Poku, Erasmus; Bading, James R.; Weist, Michael R.; Miller, Marcia M.; Colcher, David M.
2017-01-01
The development of improved breast cancer screening methods is hindered by a lack of cancer-specific imaging agents and effective small-animal models to test them. The purpose of this study was to evaluate 64Cu-DOTA-alendronate as a mammary microcalcification-targeting PET imaging agent, using an ideal rat model. Our long-term goal is to develop 64Cu-DOTA-alendronate for the detection and noninvasive differentiation of malignant versus benign breast tumors with PET. Methods: DOTA-alendronate was synthesized, radiolabeled with 64Cu, and administered to normal or tumor-bearing aged, female, retired breeder Sprague–Dawley rats for PET imaging. Mammary tissues were subsequently labeled and imaged with light, confocal, and electron microscopy to verify microcalcification targeting specificity of DOTA-alendronate and elucidate the histologic and ultrastructural characteristics of the microcalcifications in different mammary tumor types. Tumor uptake, biodistribution, and dosimetry studies were performed to evaluate the efficacy and safety of 64Cu-DOTA-alendronate. Results: 64Cu-DOTA-alendronate was radiolabeled with a 98% yield. PET imaging using aged, female, retired breeder rats showed specific binding of 64Cu-DOTA-alendronate in mammary glands and mammary tumors. The highest uptake of 64Cu-DOTA-alendronate was in malignant tumors and the lowest uptake in benign tumors and normal mammary tissue. Confocal analysis with carboxyfluorescein-alendronate confirmed the microcalcification binding specificity of alendronate derivatives. Biodistribution studies revealed tissue alendronate concentrations peaking within the first hour, then decreasing over the next 48 h. Our dosimetric analysis demonstrated a 64Cu effective dose within the acceptable range for clinical PET imaging agents and the potential for translation into human patients. Conclusion: 64Cu-DOTA-alendronate is a promising PET imaging agent for the sensitive and specific detection of mammary tumors as well as the differentiation of malignant versus benign tumors based on absolute labeling uptake. PMID:28450564
Cluster Stability Estimation Based on a Minimal Spanning Trees Approach
NASA Astrophysics Data System (ADS)
Volkovich, Zeev (Vladimir); Barzily, Zeev; Weber, Gerhard-Wilhelm; Toledano-Kitai, Dvora
2009-08-01
Among the areas of data and text mining which are employed today in science, economy and technology, clustering theory serves as a preprocessing step in the data analyzing. However, there are many open questions still waiting for a theoretical and practical treatment, e.g., the problem of determining the true number of clusters has not been satisfactorily solved. In the current paper, this problem is addressed by the cluster stability approach. For several possible numbers of clusters we estimate the stability of partitions obtained from clustering of samples. Partitions are considered consistent if their clusters are stable. Clusters validity is measured as the total number of edges, in the clusters' minimal spanning trees, connecting points from different samples. Actually, we use the Friedman and Rafsky two sample test statistic. The homogeneity hypothesis, of well mingled samples within the clusters, leads to asymptotic normal distribution of the considered statistic. Resting upon this fact, the standard score of the mentioned edges quantity is set, and the partition quality is represented by the worst cluster corresponding to the minimal standard score value. It is natural to expect that the true number of clusters can be characterized by the empirical distribution having the shortest left tail. The proposed methodology sequentially creates the described value distribution and estimates its left-asymmetry. Numerical experiments, presented in the paper, demonstrate the ability of the approach to detect the true number of clusters.
Cytologic features of the normal pineal gland on squash preparations.
Murro, Diana; Alsadi, Alaa; Nag, Sukriti; Arvanitis, Leonidas; Gattuso, Paolo
2014-11-01
As primary pineal lesions are extremely rare, many surgical pathologists are unfamiliar with normal pineal cytologic features. We describe cytologic features of the normal pineal gland in patients of varying ages and identify common diagnostic pitfalls. We performed a retrospective review of pineal gland biopsies performed at our institution, where approximately 30,000 surgical specimens are accessioned yearly, for the last 23 years. Only two pineal gland biopsies were found. Although both cases were initially diagnosed as low-grade gliomas on frozen section, the final diagnosis was benign pineal tissue based on light microscopy and immunohistochemistry results. Additionally, we performed squash preparations of five normal pineal gland autopsy specimens with Papanicolaou and Diff-Quik® (Dade Behring, Newark, DE) stains. Infant preparations were highly cellular smears composed of numerous, uniform, single cells with indistinct cytoplasm, small round-to-oval nuclei, fine chromatin, and absent nucleoli and calcifications. The vague microfollicular pattern mimicked a pineocytoma and the fine fibrillary background mimicked a glial neoplasm. Young adult smears were similar; however, microcalcifications were present with fewer background single cells. Older patients had much less cellular smears composed of small clusters of cells with fusiform-to-spindle nuclei, a fine chromatin pattern, and indistinct cytoplasmic borders. There were fewer background single cells and more microcalcifications. The cytologic features of the native pineal gland vary with age. Normal pineal tissue can be confused with a pineocytoma or low-grade glioma. Familiarity with normal pineal gland cytological features will help to avoid a potential misdiagnosis. © 2014 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico
Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performancemore » of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8–1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. Conclusions: By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.« less
Intrinsic scatter of caustic masses and hydrostatic bias: An observational study
NASA Astrophysics Data System (ADS)
Andreon, S.; Trinchieri, G.; Moretti, A.; Wang, J.
2017-10-01
All estimates of cluster mass have some intrinsic scatter and perhaps some bias with true mass even in the absence of measurement errors for example caused by cluster triaxiality and large scale structure. Knowledge of the bias and scatter values is fundamental for both cluster cosmology and astrophysics. In this paper we show that the intrinsic scatter of a mass proxy can be constrained by measurements of the gas fraction because masses with higher values of intrinsic scatter with true mass produce more scattered gas fractions. Moreover, the relative bias of two mass estimates can be constrained by comparing the mean gas fraction at the same (nominal) cluster mass. Our observational study addresses the scatter between caustic (I.e., dynamically estimated) and true masses, and the relative bias of caustic and hydrostatic masses. For these purposes, we used the X-ray Unbiased Cluster Sample, a cluster sample selected independently from the intracluster medium content with reliable masses: 34 galaxy clusters in the nearby (0.050 < z < 0.135) Universe, mostly with 14 < log M500/M⊙ ≲ 14.5, and with caustic masses. We found a 35% scatter between caustic and true masses. Furthermore, we found that the relative bias between caustic and hydrostatic masses is small, 0.06 ± 0.05 dex, improving upon past measurements. The small scatter found confirms our previous measurements of a highly variable amount of feedback from cluster to cluster, which is the cause of the observed large variety of core-excised X-ray luminosities and gas masses.
Morphological filtering and multiresolution fusion for mammographic microcalcification detection
NASA Astrophysics Data System (ADS)
Chen, Lulin; Chen, Chang W.; Parker, Kevin J.
1997-04-01
Mammographic images are often of relatively low contrast and poor sharpness with non-stationary background or clutter and are usually corrupted by noise. In this paper, we propose a new method for microcalcification detection using gray scale morphological filtering followed by multiresolution fusion and present a unified general filtering form called the local operating transformation for whitening filtering and adaptive thresholding. The gray scale morphological filters are used to remove all large areas that are considered as non-stationary background or clutter variations, i.e., to prewhiten images. The multiresolution fusion decision is based on matched filter theory. In addition to the normal matched filter, the Laplacian matched filter which is directly related through the wavelet transforms to multiresolution analysis is exploited for microcalcification feature detection. At the multiresolution fusion stage, the region growing techniques are used in each resolution level. The parent-child relations between resolution levels are adopted to make final detection decision. FROC is computed from test on the Nijmegen database.
Reljin, Branimir; Milosević, Zorica; Stojić, Tomislav; Reljin, Irini
2009-01-01
Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal "images" are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph.
NASA Astrophysics Data System (ADS)
Bruynooghe, Michel M.
1998-04-01
In this paper, we present a robust method for automatic object detection and delineation in noisy complex images. The proposed procedure is a three stage process that integrates image segmentation by multidimensional pixel clustering and geometrically constrained optimization of deformable contours. The first step is to enhance the original image by nonlinear unsharp masking. The second step is to segment the enhanced image by multidimensional pixel clustering, using our reducible neighborhoods clustering algorithm that has a very interesting theoretical maximal complexity. Then, candidate objects are extracted and initially delineated by an optimized region merging algorithm, that is based on ascendant hierarchical clustering with contiguity constraints and on the maximization of average contour gradients. The third step is to optimize the delineation of previously extracted and initially delineated objects. Deformable object contours have been modeled by cubic splines. An affine invariant has been used to control the undesired formation of cusps and loops. Non linear constrained optimization has been used to maximize the external energy. This avoids the difficult and non reproducible choice of regularization parameters, that are required by classical snake models. The proposed method has been applied successfully to the detection of fine and subtle microcalcifications in X-ray mammographic images, to defect detection by moire image analysis, and to the analysis of microrugosities of thin metallic films. The later implementation of the proposed method on a digital signal processor associated to a vector coprocessor would allow the design of a real-time object detection and delineation system for applications in medical imaging and in industrial computer vision.
Hepatic alveolar echinococcosis: correlative US and CT study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Didier, D.; Weiler, S.; Rohmer, P.
1985-01-01
A total of 24 cases of hepatic alveolar echinococcosis (HAE) due to Echinococcus multilocularis was assessed by US and CT. The diagnosis was confirmed in all cases by immunologic and histologic study. Both US and CT patterns of HAE showed changes of liver morphology in both contour and size. Abnormal areas of parenchyma were nodular or in fields, irregular, heterogeneous, and basically echogenic. Clustered microcalcifications were encountered within the abnormal parenchymal fields in 50% of cases, and necrotized zones occurred in 40% of cases. Dilatation of intrahepatic bile ducts was commonly seen, especially on US; hilar involvement was frequent. Follow-upmore » by both techniques can display increases of primary lesions, occurrence of new foci, and local or regional extensions. Precise evaluations of the lesions arising from correlative use of US and CT permits adequate therapeutic management.« less
Mammographic images segmentation based on chaotic map clustering algorithm
2014-01-01
Background This work investigates the applicability of a novel clustering approach to the segmentation of mammographic digital images. The chaotic map clustering algorithm is used to group together similar subsets of image pixels resulting in a medically meaningful partition of the mammography. Methods The image is divided into pixels subsets characterized by a set of conveniently chosen features and each of the corresponding points in the feature space is associated to a map. A mutual coupling strength between the maps depending on the associated distance between feature space points is subsequently introduced. On the system of maps, the simulated evolution through chaotic dynamics leads to its natural partitioning, which corresponds to a particular segmentation scheme of the initial mammographic image. Results The system provides a high recognition rate for small mass lesions (about 94% correctly segmented inside the breast) and the reproduction of the shape of regions with denser micro-calcifications in about 2/3 of the cases, while being less effective on identification of larger mass lesions. Conclusions We can summarize our analysis by asserting that due to the particularities of the mammographic images, the chaotic map clustering algorithm should not be used as the sole method of segmentation. It is rather the joint use of this method along with other segmentation techniques that could be successfully used for increasing the segmentation performance and for providing extra information for the subsequent analysis stages such as the classification of the segmented ROI. PMID:24666766
McCroskey, Zulfia; Sneige, Nour; Herman, Carolyn R; Miller, Ross A; Venta, Luz A; Ro, Jae Y; Schwartz, Mary R; Ayala, Alberto G
2018-02-21
The aim of this study was to analyze the clinicopathological features of patients with flat epithelial atypia, diagnosed in directional vacuum-assisted biopsy targeting microcalcifications, to identify upgrade rate to in situ ductal or invasive breast carcinoma, and determine factors predicting carcinoma in the subsequent excision. We retrospectively evaluated the histological, clinical, and mammographic features of 69 cases from 65 women, with directional vacuum-assisted biopsy-diagnosed flat epithelial atypia with or without atypical ductal hyperplasia or atypical lobular hyperplasia, which underwent subsequent surgical excision. The extent and percentage of microcalcifications sampled by directional vacuum-assisted biopsy were evaluated by mammography. All biopsy and surgical excision slides were reviewed. The age of the women ranged from 40 to 85 years (mean 57 years). All patients presented with mammographically detected microcalcifications only, except in one case that had associated architectural distortion. Extent of calcifications ranged from <1 cm (n = 47), 1-3 cm (n = 15) to > 3 cm (n = 6), and no measurement (n = 1). A mean of 11 cores (range 6-25) was obtained from each lesion. Post-biopsy mammogram revealed >90% removal of calcifications in 81% of cases. Pure flat epithelial atypia represented nearly two-thirds of directional vacuum-assisted biopsy specimens (n = 43, 62%), while flat epithelial atypia coexisted with atypical ductal hyperplasia (18 cases, 26%), or atypical lobular hyperplasia (8 cases, 12%). Upon excision, none of the cases were upgraded to in situ ductal or invasive breast cancer. In one case, however, an incidental, tubular carcinoma (4 mm) was found away from biopsy site. Excluding this case, the upgrade rate was 0%. Our study adds to the growing evidence that diagnosis of flat epithelial atypia on directional vacuum-assisted biopsy for microcalcifications as the only imaging finding is not associated with a significant upgrade to carcinoma on excision, and therefore, excision may not be necessary. Additionally, excision may not be necessary for flat epithelial atypia with atypical ductal hyperplasia limited to ≤2 terminal duct-lobular units, if at least 90% of calcifications have been removed on biopsy.
Schiaffino, Simone; Gristina, Licia; Villa, Alessandro; Tosto, Simona; Monetti, Francesco; Carli, Franca; Calabrese, Massimo
2018-01-01
To determine the malignancy rate (defined in this study as stability or absence of malignancy developed on close imaging follow-up post-biopsy) of conservative management in patients with a vacuum-assisted breast biopsy (VAB) diagnosis of flat epithelial atypia (FEA), performed on single group of microcalcifications, completely removed during procedure. This is a retrospective, monocentric, observational study, approved by IRB. Inclusion criteria were: VAB performed on a single group of microcalcifications; the absence of residual calcifications post-VAB; diagnosis of isolated FEA as the most advanced proliferative lesion; radiological follow-up at least of 12 months. The personal history of breast cancer or other high-risk lesions was an exclusion criteria. The patients enrolled were conservatively managed, without surgical excision, through close follow-up: the first two mammographies performed with an interval of 6 months after biopsy, followed by annual mammographic and clinical checks. 48 consecutive patients were enrolled in the study, all females, with age range of 39-76 years (mean 53,3 years) and radiological follow-up range of 13-75 months (mean 41.5 months). All the lesions were classified as BI-RADS 4b. The diameter range of the group of calcifications was 3-10 mm (mean 5, 6 mm). In each patient, 7 to 15 samples (mean 11) were obtained. Among all the patients, there was only one case (2%) of new microcalcifications, developed in the same breast, 26 months after and 8 mm from the site of previous VAB, and interpreted as ADH at surgical excision. All the checks of the other patients were negative. Even with a limited follow-up, we found a malignancy rate lower than 2%, through a defined population. Further studies with bigger number of patients and extended follow-up are needed to reinforce this hypothesis. Advances in knowledge: Surgical excision may not be necessary in patients with VAB diagnosis of isolated FEA, without residual microcalcifications post-procedure and considered concordant with the mammographic presentation, considering the low rate of malignancy at subsequent follow-ups.
A novel approach to breast cancer diagnosis via PET imaging of microcalcifications using 18F-NaF
Wilson, George H.; Gore, John C.; Yankeelov, Thomas E.; Barnes, Stephanie; Peterson, Todd E.; True, Jarrod M.; Shokouhi, Sepideh; McIntyre, J. Oliver.; Sanders, Melinda; Abramson, Vandana; Ngyuen, The-Quyen; Mahadevan-Jansen, Anita; Tantawy, Mohammed N.
2015-01-01
Rationale Current radiological methods for diagnosing breast cancer detect specific morphological features of solid tumors and/or any associated calcium deposits. These deposits originate from an early molecular microcalcification process which consists of two types: type 1 is calcium oxylate (CO) and type II is carbonated calcium hydroxyapetite (HAP). Type I microcalcifications are mainly associated with benign tumors while type II have been shown to be produced, internally, by malignant cells. No current non-invasive in vivo techniques are available for detecting intratumoral microcalcifications. Such a technique would have a significant impact on breast cancer diagnosis and prognosis in preclinical and clinical settings. 18F-NaF PET has been solely used for bone imaging by targeting the bone HAP. In this work, we provide preliminary evidence that 18F-NaF PET imaging can be used to detect breast cancer by targeting the HAP lattice within the tumor microenvironment with high specificity and soft-tissue contrast-to-background ratio, while delineating tumors from inflammation. METHODS Mice were injected with approximately 106 MDA-MB-231 cells subcutaneously and imaged with 18F-NaF PET/CT in a 120 min dynamic sequence when the tumors reached a size of ~250 mm3. Regions-of-interest (ROIs) were drawn around the tumor, muscle, and bone. The concentration of the radiotracer within those ROIs were compared to one another. For comparison to inflammation, rats with inflammatory paws were subjected to 18F-NaF PET imaging. RESULTS Tumor uptake of 18F− was significantly higher (p<0.05) than muscle uptake where the tumor-to-muscle ratio was ~3.5. The presence of type II microcalcification in the MDA-MB-231 cell line was confirmed histologically using alizarin red S and von Kossa staining as well as Raman microspectroscopy. No uptake of 18F− was observed in the rat inflamed tissue. Lack of HAP in the inflamed tissue was verified histologically. CONCLUSIONS This study provides preliminary evidence suggesting that specific targeting of the HAP within the tumor microenvironment with 18F may be able to distinguishing between inflammation and cancer. PMID:24833491
Kitahama, H
1991-05-25
The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area = 0.91) was better than that on film-screen mammography (ROC area = 0.88) (p less than 0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study.
Maxwell, Anthony J; Clements, Karen; Dodwell, David J; Evans, Andrew J; Francis, Adele; Hussain, Monuwar; Morris, Julie; Pinder, Sarah E; Sawyer, Elinor J; Thomas, Jeremy; Thompson, Alastair
2016-06-01
To investigate the radiological features, diagnosis and management of screen-detected lobular neoplasia (LN) of the breast. 392 women with pure LN alone were identified within the prospective UK cohort study of screen-detected non-invasive breast neoplasia (the Sloane Project). Demography, radiological features and diagnostic and therapeutic procedures were analysed. Non-pleomorphic LN (369/392) was most frequently diagnosed among women aged 50-54 and in 53.5% was at the first screen. It occurred most commonly on the left (58.0%; p = 0.003), in the upper outer quadrant and confined to one site (single quadrant or retroareolar region). No bilateral cases were found. The predominant radiological feature was microcalcification (most commonly granular) which increased in frequency with increasing breast density. Casting microcalcification as a predominant feature had a significantly higher lesion size compared to granular and punctate patterns (p = 0.034). 326/369 (88.3%) women underwent surgery, including 17 who underwent >1 operation, six who had mastectomy and six who had axillary surgery. Two patients had radiotherapy and 15 had endocrine treatment. Pleomorphic lobular carcinoma in situ (23/392) presented as granular microcalcification in 12; four women had mastectomy and six had radiotherapy. Screen-detected LN occurs in relatively young women and is predominantly non-pleomorphic and unilateral. It is typically associated with granular or punctate microcalcification in the left upper outer quadrant. Management, including surgical resection, is highly variable and requires evidence-based guideline development. Copyright © 2016 Elsevier Ltd. All rights reserved.
An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography.
Treiber, O; Wanninger, F; Führ, H; Panzer, W; Regulla, D; Winkler, G
2003-02-21
This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing. a dose reduction by 25% has no serious influence on the detection results. whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.
An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography
NASA Astrophysics Data System (ADS)
Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.
2003-02-01
This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.
Huang, Xu Chen; Hu, Xu Hua; Wang, Xiao Ran; Zhou, Chao Xi; Wang, Fei Fei; Yang, Shan; Wang, Gui Ying
2018-03-16
Core needle biopsy (CNB) and vacuum-assisted biopsy (VAB) are both popularly used breast percutaneous biopsies. Both of them have become reliable alternatives to open surgical biopsy (OSB) for breast microcalcification (BM). It is controversial that which biopsy method is more accurate and safer for BM. Hence, we conducted this meta-analysis to compare the diagnostic performance between CNB and VAB for BM, aiming to find out the better method. Articles according with including and excluding criteria were collected from the databases, PubMed, Embase, and the Cochrane Library. Preset outcomes were abstracted and pooled to find out the potential advantages in CNB or VAB. Seven studies were identified and entered final meta-analysis from initially found 138 studies. The rate of ductal carcinoma in situ (DCIS) underestimation was significantly lower in VAB than CNB group [risk ratio (RR) = 1.83, 95% confidence interval (CI) 1.40 to 2.40, p < 0.001]. The microcalcification retrieval rate was significantly higher in VAB than CNB group (RR = 0.89, 95% CI 0.81 to 0.98, p = 0.02), while CNB owned a significantly lower complication rate than VAB (RR = 0.18, 95% CI 0.03 to 0.93, p = 0.04). The atypical ductal hyperplasia (ADH) underestimation rates were not compared for the limited number of studies reporting this outcome. Compared with CNB, VAB shows better diagnostic performance in DCIS underestimation rate and microcalcification retrieval rate. However, CNB shows a significantly lower complication rate. More studies are needed to verify these findings.
Bansal, Ravi; Peterson, Bradley S
2018-06-01
Identifying regional effects of interest in MRI datasets usually entails testing a priori hypotheses across many thousands of brain voxels, requiring control for false positive findings in these multiple hypotheses testing. Recent studies have suggested that parametric statistical methods may have incorrectly modeled functional MRI data, thereby leading to higher false positive rates than their nominal rates. Nonparametric methods for statistical inference when conducting multiple statistical tests, in contrast, are thought to produce false positives at the nominal rate, which has thus led to the suggestion that previously reported studies should reanalyze their fMRI data using nonparametric tools. To understand better why parametric methods may yield excessive false positives, we assessed their performance when applied both to simulated datasets of 1D, 2D, and 3D Gaussian Random Fields (GRFs) and to 710 real-world, resting-state fMRI datasets. We showed that both the simulated 2D and 3D GRFs and the real-world data contain a small percentage (<6%) of very large clusters (on average 60 times larger than the average cluster size), which were not present in 1D GRFs. These unexpectedly large clusters were deemed statistically significant using parametric methods, leading to empirical familywise error rates (FWERs) as high as 65%: the high empirical FWERs were not a consequence of parametric methods failing to model spatial smoothness accurately, but rather of these very large clusters that are inherently present in smooth, high-dimensional random fields. In fact, when discounting these very large clusters, the empirical FWER for parametric methods was 3.24%. Furthermore, even an empirical FWER of 65% would yield on average less than one of those very large clusters in each brain-wide analysis. Nonparametric methods, in contrast, estimated distributions from those large clusters, and therefore, by construct rejected the large clusters as false positives at the nominal FWERs. Those rejected clusters were outlying values in the distribution of cluster size but cannot be distinguished from true positive findings without further analyses, including assessing whether fMRI signal in those regions correlates with other clinical, behavioral, or cognitive measures. Rejecting the large clusters, however, significantly reduced the statistical power of nonparametric methods in detecting true findings compared with parametric methods, which would have detected most true findings that are essential for making valid biological inferences in MRI data. Parametric analyses, in contrast, detected most true findings while generating relatively few false positives: on average, less than one of those very large clusters would be deemed a true finding in each brain-wide analysis. We therefore recommend the continued use of parametric methods that model nonstationary smoothness for cluster-level, familywise control of false positives, particularly when using a Cluster Defining Threshold of 2.5 or higher, and subsequently assessing rigorously the biological plausibility of the findings, even for large clusters. Finally, because nonparametric methods yielded a large reduction in statistical power to detect true positive findings, we conclude that the modest reduction in false positive findings that nonparametric analyses afford does not warrant a re-analysis of previously published fMRI studies using nonparametric techniques. Copyright © 2018 Elsevier Inc. All rights reserved.
Analysis of perceived similarity between pairs of microcalcification clusters in mammograms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Juan; Jing, Hao; Wernick, Miles N.
2014-05-15
Purpose: Content-based image retrieval aims to assist radiologists by presenting example images with known pathology that are visually similar to the case being evaluated. In this work, the authors investigate several fundamental issues underlying the similarity ratings between pairs of microcalcification (MC) lesions on mammograms as judged by radiologists: the degree of variability in the similarity ratings, the impact of this variability on agreement between readers in retrieval of similar lesions, and the factors contributing to the readers’ similarity ratings. Methods: The authors conduct a reader study on a set of 1000 image pairs of MC lesions, in which amore » group of experienced breast radiologists rated the degree of similarity between each image pair. The image pairs are selected, from among possible pairings of 222 cases (110 malignant, 112 benign), based on quantitative image attributes (features) and the results of a preliminary reader study. Next, the authors apply analysis of variance (ANOVA) to quantify the level of variability in the readers’ similarity ratings, and study how the variability in individual reader ratings affects consistency between readers. The authors also measure the extent to which readers agree on images which are most similar to a given query, for which the Dice coefficient is used. To investigate how the similarity ratings potentially relate to the attributes underlying the cases, the authors study the fraction of perceptually similar images that also share the same benign or malignant pathology as the query image; moreover, the authors apply multidimensional scaling (MDS) to embed the cases according to their mutual perceptual similarity in a two-dimensional plot, which allows the authors to examine the manner in which similar lesions relate to one another in terms of benign or malignant pathology and clustered MCs. Results: The ANOVA results show that the coefficient of determination in the reader similarity ratings is 0.59. The variability level in the similarity ratings is proved to be a limiting factor, leading to only moderate correlation between the readers in their readings. The Dice coefficient, measuring agreement between readers in retrieval of similar images, can vary from 0.45 to 0.64 with different levels of similarity for individual readers, but is higher for average ratings from a group of readers (from 0.59 to 0.78). More importantly, the fraction of retrieved cases that match the benign or malignant pathology of the query image was found to increase with the degree of similarity among the retrieved images, reaching average value as high as 0.69 for the radiologists (p-value <10{sup −4} compared to random guessing). Moreover, MDS embedding of all the cases shows that cases having the same pathology tend to cluster together, and that neighboring cases in the plot tend to be similar in their clustered MCs. Conclusions: While individual readers exhibit substantial variability in their similarity ratings, similarity ratings averaged from a group of readers can achieve a high level of intergroup consistency and agreement in retrieval of similar images. More importantly, perceptually similar cases are also likely to be similar in their underlying benign or malignant pathology and image features of clustered MCs, which could be of diagnostic value in computer-aided diagnosis for lesions with clustered MCs.« less
Yoshimoto, Junichiro; Shimizu, Yu; Okada, Go; Takamura, Masahiro; Okamoto, Yasumasa; Yamawaki, Shigeto; Doya, Kenji
2017-01-01
We propose a novel method for multiple clustering, which is useful for analysis of high-dimensional data containing heterogeneous types of features. Our method is based on nonparametric Bayesian mixture models in which features are automatically partitioned (into views) for each clustering solution. This feature partition works as feature selection for a particular clustering solution, which screens out irrelevant features. To make our method applicable to high-dimensional data, a co-clustering structure is newly introduced for each view. Further, the outstanding novelty of our method is that we simultaneously model different distribution families, such as Gaussian, Poisson, and multinomial distributions in each cluster block, which widens areas of application to real data. We apply the proposed method to synthetic and real data, and show that our method outperforms other multiple clustering methods both in recovering true cluster structures and in computation time. Finally, we apply our method to a depression dataset with no true cluster structure available, from which useful inferences are drawn about possible clustering structures of the data. PMID:29049392
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salvagnini, Elena, E-mail: elena.salvagnini@gmail.
Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settingsmore » for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating characteristic analysis was applied. Results: For part 1, the alternative free-response receiver operating characteristic curves for the four readers were 0.80, 0.65, 0.55 and 0.56 in going from T1 to T4, indicating a decrease in detectability with increasing breast thickness. P-values and the 95% confidence interval showed no significant difference for the T3-T4 comparison (p = 0.78) while all the other differences were significant (p < 0.05). Separate analysis of microcalcification clusters presented the same results while for mass detection, the only significant difference came when comparing T1 to the other thickness groups. Comparing the scores of part 1 and part 2, results for the T3 group acquired with the new AEC setup and T3 group at standard AEC doses were significantly different (p = 0.0004), indicating improved detection. For this group a subanalysis for microcalcification detection gave the same results while no significant difference was found for mass detection. Conclusions: These data using clinical images confirm results found in simple QA tests for many mammography systems that detectability falls as breast thickness increases. Results obtained with the AEC setup for constant detectability above 49 mm showed an increase in lesion detection with compressed breast thickness, bringing detectability of lesions to the same level.« less
Gaussian mixture clustering and imputation of microarray data.
Ouyang, Ming; Welsh, William J; Georgopoulos, Panos
2004-04-12
In microarray experiments, missing entries arise from blemishes on the chips. In large-scale studies, virtually every chip contains some missing entries and more than 90% of the genes are affected. Many analysis methods require a full set of data. Either those genes with missing entries are excluded, or the missing entries are filled with estimates prior to the analyses. This study compares methods of missing value estimation. Two evaluation metrics of imputation accuracy are employed. First, the root mean squared error measures the difference between the true values and the imputed values. Second, the number of mis-clustered genes measures the difference between clustering with true values and that with imputed values; it examines the bias introduced by imputation to clustering. The Gaussian mixture clustering with model averaging imputation is superior to all other imputation methods, according to both evaluation metrics, on both time-series (correlated) and non-time series (uncorrelated) data sets.
Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.
Vikhe, P S; Thool, V R
2016-04-01
Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.
Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.
Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime
2014-01-01
The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.
Shakeri, Shadi A.; Abbey, Craig K.; Gazi, Peymon; Prionas, Nicolas; Nosratieh, Anita; Li, Chin-Shang; Boone, John M.; Lindfors, Karen K.
2015-01-01
Purpose Compare conspicuity of ductal carcinoma in-situ (DCIS) to benign calcifications on unenhanced (bCT), contrast-enhanced dedicated breast CT (CEbCT) and mammography (DM). Methods and Materials The institutional review board approved this HIPAA-compliant study. 42 women with Breast Imaging Reporting and Data System 4 or 5 category micro-calcifications had breast CT before biopsy. Three subjects with invasive disease at surgery were excluded. Two breast radiologists independently compared lesion conspicuity scores (CS) for CEbCT, to bCT and DM. Enhancement was measured in Hounsfield units (HU). Mean CS ± standard deviations are shown. Receiver operating characteristic analysis (ROC) measured radiologists’ discrimination performance by comparing CS to enhancement alone. Statistical measurements were made using ANOVA F-test, Wilcoxon rank-sum test and robust linear regression analyses. Results 39 lesions (17 DCIS, 22 benign) were analyzed. DCIS (8.5±0.9, n=17) was more conspicuous than benign micro-calcifications (3.6±2.9, n=22; p<0.0001) on CEbCT. DCIS was equally conspicuous on CEbCT and DM (8.5±0.9, 8.7±0.8, n=17; p=0.85) and more conspicuous when compared to bCT (5.3±2.6, n=17; p<0.001). All DCIS enhanced; mean enhancement (90HU ±53HU, n=17) was higher compared to benign lesions (33 ±30HU, n=22)(p<0.0001). ROC analysis of the radiologists’ CS showed high discrimination performance (AUC=0.94) compared to enhancement alone (AUC=0.85) (p<0.026). Conclusion DCIS is more conspicuous than benign micro-calcifications on CEbCT. DCIS visualization on CEbCT is equal to mammography but improved compared to bCT. Radiologists’ discrimination performance using CEBCT is significantly higher than enhancement values alone. CEbCT may have an advantage over mammography by reducing false positive examinations when calcifications are analyzed. PMID:26520874
Kalluri, Kesava S.; Mahd, Mufeed; Glick, Stephen J.
2013-01-01
Purpose: Breast CT is an emerging imaging technique that can portray the breast in 3D and improve visualization of important diagnostic features. Early clinical studies have suggested that breast CT has sufficient spatial and contrast resolution for accurate detection of masses and microcalcifications in the breast, reducing structural overlap that is often a limiting factor in reading mammographic images. For a number of reasons, image quality in breast CT may be improved by use of an energy resolving photon counting detector. In this study, the authors investigate the improvements in image quality obtained when using energy weighting with an energy resolving photon counting detector as compared to that with a conventional energy integrating detector. Methods: Using computer simulation, realistic CT images of multiple breast phantoms were generated. The simulation modeled a prototype breast CT system using an amorphous silicon (a-Si), CsI based energy integrating detector with different x-ray spectra, and a hypothetical, ideal CZT based photon counting detector with capability of energy discrimination. Three biological signals of interest were modeled as spherical lesions and inserted into breast phantoms; hydroxyapatite (HA) to represent microcalcification, infiltrating ductal carcinoma (IDC), and iodine enhanced infiltrating ductal carcinoma (IIDC). Signal-to-noise ratio (SNR) of these three lesions was measured from the CT reconstructions. In addition, a psychophysical study was conducted to evaluate observer performance in detecting microcalcifications embedded into a realistic anthropomorphic breast phantom. Results: In the energy range tested, improvements in SNR with a photon counting detector using energy weighting was higher (than the energy integrating detector method) by 30%–63% and 4%–34%, for HA and IDC lesions and 12%–30% (with Al filtration) and 32%–38% (with Ce filtration) for the IIDC lesion, respectively. The average area under the receiver operating characteristic curve (AUC) for detection of microcalcifications was higher by greater than 19% (for the different energy weighting methods tested) as compared to the AUC obtained with an energy integrating detector. Conclusions: This study showed that breast CT with a CZT photon counting detector using energy weighting can provide improvements in pixel SNR, and detectability of microcalcifications as compared to that with a conventional energy integrating detector. Since a number of degrading physical factors were not modeled into the photon counting detector, this improvement should be considered as an upper bound on achievable performance. PMID:23927337
Pezzoli, Lorenzo; Pineda, Silvia; Halkyer, Percy; Crespo, Gladys; Andrews, Nick; Ronveaux, Olivier
2009-03-01
To estimate the yellow fever (YF) vaccine coverage for the endemic and non-endemic areas of Bolivia and to determine whether selected districts had acceptable levels of coverage (>70%). We conducted two surveys of 600 individuals (25 x 12 clusters) to estimate coverage in the endemic and non-endemic areas. We assessed 11 districts using lot quality assurance sampling (LQAS). The lot (district) sample was 35 individuals with six as decision value (alpha error 6% if true coverage 70%; beta error 6% if true coverage 90%). To increase feasibility, we divided the lots into five clusters of seven individuals; to investigate the effect of clustering, we calculated alpha and beta by conducting simulations where each cluster's true coverage was sampled from a normal distribution with a mean of 70% or 90% and standard deviations of 5% or 10%. Estimated coverage was 84.3% (95% CI: 78.9-89.7) in endemic areas, 86.8% (82.5-91.0) in non-endemic and 86.0% (82.8-89.1) nationally. LQAS showed that four lots had unacceptable coverage levels. In six lots, results were inconsistent with the estimated administrative coverage. The simulations suggested that the effect of clustering the lots is unlikely to have significantly increased the risk of making incorrect accept/reject decisions. Estimated YF coverage was high. Discrepancies between administrative coverage and LQAS results may be due to incorrect population data. Even allowing for clustering in LQAS, the statistical errors would remain low. Catch-up campaigns are recommended in districts with unacceptable coverage.
A Note on Cluster Effects in Latent Class Analysis
ERIC Educational Resources Information Center
Kaplan, David; Keller, Bryan
2011-01-01
This article examines the effects of clustering in latent class analysis. A comprehensive simulation study is conducted, which begins by specifying a true multilevel latent class model with varying within- and between-cluster sample sizes, varying latent class proportions, and varying intraclass correlations. These models are then estimated under…
Cone-beam micro computed tomography dedicated to the breast.
Sarno, Antonio; Mettivier, Giovanni; Di Lillo, Francesca; Cesarelli, Mario; Bifulco, Paolo; Russo, Paolo
2016-12-01
We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2mm -1 (MTF at 10%) in the vertical direction and 3.8mm -1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1-2min long scan times without breast motion artifacts. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Identifying seizure clusters in patients with epilepsy
Lipton, R. B.; LeValley, A. J.; Hall, C. B.; Shinnar, S.
2006-01-01
Clinicians often encounter patients whose neurologic attacks appear to cluster. In a daily diary study, the authors explored whether clustering is a true phenomenon in epilepsy and can be identified in the clinical setting. Nearly half the subjects experienced at least one episode of three or more seizures in 24 hours; 20% also met a statistical clustering criterion. Utilizing the clinical definition of clustering should identify all seizure clusterers, and false positives can be determined with diary data. PMID:16247068
El Khoury, M; Mesurolle, B; Omeroglu, A; Aldis, A; Kao, E
2013-05-01
Determine values of pathological analysis of the canister content during a vacuum-assisted breast biopsy (VABB). Approval was obtained from the ethical committee. Prospective radiological and pathological analyses of the canister content collected during 231 VABBs performed on 231 patients were carried out. χ(2) test was used to determine predictors on canister pathology. The canister pathology was reported separately in 212 cases. It showed only blood in 78/212 (37%) cases and benign (including high-risk lesions) and malignant results in, respectively, 113/212 (53%) and 21/212 (10%) cases. Respective specimen analysis was benign, including high-risk lesions in 162/212 cases (76%) and malignant in 50/212 (24%) cases. Microcalcifications were documented on canister X-ray in 70/231 (30%) cases. There was significant association between the canister and the specimen pathology (p<0.0001). In none of the cases was microcalcifications seen exclusively in the canister content or pathological upgrading found in the canister content compared with the specimen. Small tissue fragments and microcalcifications may be lost in the canister during a VABB. Nevertheless, our results did not show any significant value for systematic analysis of the canister content. There is no added diagnostic value to retrieval and analysis of tissue lost in the canister during a VABB.
Evaluation of search strategies for microcalcifications and masses in 3D images
NASA Astrophysics Data System (ADS)
Eckstein, Miguel P.; Lago, Miguel A.; Abbey, Craig K.
2018-03-01
Medical imaging is quickly evolving towards 3D image modalities such as computed tomography (CT), magnetic resonance imaging (MRI) and digital breast tomosynthesis (DBT). These 3D image modalities add volumetric information but further increase the need for radiologists to search through the image data set. Although much is known about search strategies in 2D images less is known about the functional consequences of different 3D search strategies. We instructed readers to use two different search strategies: drillers had their eye movements restricted to a few regions while they quickly scrolled through the image stack, scanners explored through eye movements the 2D slices. We used real-time eye position monitoring to ensure observers followed the drilling or the scanning strategy while approximately preserving the percentage of the volumetric data covered by the useful field of view. We investigated search for two signals: a simulated microcalcification and a larger simulated mass. Results show an interaction between the search strategy and lesion type. In particular, scanning provided significantly better detectability for microcalcifications at the cost of 5 times more time to search while there was little change in the detectability for the larger simulated masses. Analyses of eye movements support the hypothesis that the effectiveness of a search strategy in 3D imaging arises from the interaction of the fixational sampling of visual information and the signals' visibility in the visual periphery.
Classification of breast microcalcifications using spectral mammography
NASA Astrophysics Data System (ADS)
Ghammraoui, B.; Glick, S. J.
2017-03-01
Purpose: To investigate the potential of spectral mammography to distinguish between type I calcifications, consisting of calcium oxalate dihydrate or weddellite compounds that are more often associated with benign lesions, and type II calcifications containing hydroxyapatite which are predominantly associated with malignant tumors. Methods: Using a ray tracing algorithm, we simulated the total number of x-ray photons recorded by the detector at one pixel from a single pencil-beam projection through a breast of 50/50 (adipose/glandular) tissues with inserted microcalcifications of different types and sizes. Material decomposition using two energy bins was then applied to characterize the simulated calcifications into hydroxyapatite and weddellite using maximumlikelihood estimation, taking into account the polychromatic source, the detector response function and the energy dependent attenuation. Results: Simulation tests were carried out for different doses and calcification sizes for multiple realizations. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to 0.99. Conclusion: Our simulation results obtained for a uniform breast imaging phantom indicate that spectral mammography using two energy bins has the potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications to improve early breast cancer diagnosis and reduce the number of unnecessary breast biopsies.
Calibrating the Planck cluster mass scale with CLASH
NASA Astrophysics Data System (ADS)
Penna-Lima, M.; Bartlett, J. G.; Rozo, E.; Melin, J.-B.; Merten, J.; Evrard, A. E.; Postman, M.; Rykoff, E.
2017-08-01
We determine the mass scale of Planck galaxy clusters using gravitational lensing mass measurements from the Cluster Lensing And Supernova survey with Hubble (CLASH). We have compared the lensing masses to the Planck Sunyaev-Zeldovich (SZ) mass proxy for 21 clusters in common, employing a Bayesian analysis to simultaneously fit an idealized CLASH selection function and the distribution between the measured observables and true cluster mass. We used a tiered analysis strategy to explicitly demonstrate the importance of priors on weak lensing mass accuracy. In the case of an assumed constant bias, bSZ, between true cluster mass, M500, and the Planck mass proxy, MPL, our analysis constrains 1-bSZ = 0.73 ± 0.10 when moderate priors on weak lensing accuracy are used, including a zero-mean Gaussian with standard deviation of 8% to account for possible bias in lensing mass estimations. Our analysis explicitly accounts for possible selection bias effects in this calibration sourced by the CLASH selection function. Our constraint on the cluster mass scale is consistent with recent results from the Weighing the Giants program and the Canadian Cluster Comparison Project. It is also consistent, at 1.34σ, with the value needed to reconcile the Planck SZ cluster counts with Planck's base ΛCDM model fit to the primary cosmic microwave background anisotropies.
A Dempster-Shafer Method for Multi-Sensor Fusion
2012-03-01
position results for DST Mean Mod (or DST Mean for Case 1) to follow the same general path as the true aircraft . Also, if the points diverged from the true...of the aircraft . Its results were similar to those for DST True and Kalman. Also DST Mean had the same clustering of points as the others specifically...DST Mean values increasingly diverged as time t increased. Then Run 27 was very similar to Case 2 Run 5. Instead of following the true aircraft path
Wang, Juan; Nishikawa, Robert M; Yang, Yongyi
2017-07-01
Mammograms acquired with full-field digital mammography (FFDM) systems are provided in both "for-processing'' and "for-presentation'' image formats. For-presentation images are traditionally intended for visual assessment by the radiologists. In this study, we investigate the feasibility of using for-presentation images in computerized analysis and diagnosis of microcalcification (MC) lesions. We make use of a set of 188 matched mammogram image pairs of MC lesions from 95 cases (biopsy proven), in which both for-presentation and for-processing images are provided for each lesion. We then analyze and characterize the MC lesions from for-presentation images and compare them with their counterparts in for-processing images. Specifically, we consider three important aspects in computer-aided diagnosis (CAD) of MC lesions. First, we quantify each MC lesion with a set of 10 image features of clustered MCs and 12 textural features of the lesion area. Second, we assess the detectability of individual MCs in each lesion from the for-presentation images by a commonly used difference-of-Gaussians (DoG) detector. Finally, we study the diagnostic accuracy in discriminating between benign and malignant MC lesions from the for-presentation images by a pretrained support vector machine (SVM) classifier. To accommodate the underlying background suppression and image enhancement in for-presentation images, a normalization procedure is applied. The quantitative image features of MC lesions from for-presentation images are highly consistent with that from for-processing images. The values of Pearson's correlation coefficient between features from the two formats range from 0.824 to 0.961 for the 10 MC image features, and from 0.871 to 0.963 for the 12 textural features. In detection of individual MCs, the FROC curve from for-presentation is similar to that from for-processing. In particular, at sensitivity level of 80%, the average number of false-positives (FPs) per image region is 9.55 for both for-presentation and for-processing images. Finally, for classifying MC lesions as malignant or benign, the area under the ROC curve is 0.769 in for-presentation, compared to 0.761 in for-processing (P = 0.436). The quantitative results demonstrate that MC lesions in for-presentation images are highly consistent with that in for-processing images in terms of image features, detectability of individual MCs, and classification accuracy between malignant and benign lesions. These results indicate that for-presentation images can be compatible with for-processing images for use in CAD algorithms for MC lesions. © 2017 American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vedantham, S; Shrestha, S; Shi, L
Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability indexmore » inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered the detectability index than 525µm CsI:Tl. Conclusion: For the x-ray spectrum and imaging conditions considered, a 525µm thick CsI:Tl scintillator integrated with the CMOS detector is optimal for detecting microcalcification cluster. Funding support: Supported in part by NIH R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI. Disclosures: SV, GV and AK - Research collaboration, Koning Corp., West Henrietta, NY.« less
Zhao, Chumin; Kanicki, Jerzy; Konstantinidis, Anastasios C; Patel, Tushita
2015-11-01
Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electronic noise (50-300 e-) of CMOS APS x-ray imagers provides a possible route to shrink the pixel pitch to smaller than 75 μm for microcalcification detection and possible reduction of the DBT mean glandular dose (MGD). In this study, imaging performance of a large area (29×23 cm2) CMOS APS x-ray imager [Dexela 2923 MAM (PerkinElmer, London)] with a pixel pitch of 75 μm was characterized and modeled. The authors developed a cascaded system model for CMOS APS x-ray imagers using both a broadband x-ray radiation and monochromatic synchrotron radiation. The experimental data including modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were theoretically described using the proposed cascaded system model with satisfactory consistency to experimental results. Both high full well and low full well (LFW) modes of the Dexela 2923 MAM CMOS APS x-ray imager were characterized and modeled. The cascaded system analysis results were further used to extract the contrast-to-noise ratio (CNR) for microcalcifications with sizes of 165-400 μm at various MGDs. The impact of electronic noise on CNR was also evaluated. The LFW mode shows better DQE at low air kerma (Ka<10 μGy) and should be used for DBT. At current DBT applications, air kerma (Ka∼10 μGy, broadband radiation of 28 kVp), DQE of more than 0.7 and ∼0.3 was achieved using the LFW mode at spatial frequency of 0.5 line pairs per millimeter (lp/mm) and Nyquist frequency ∼6.7 lp/mm, respectively. It is shown that microcalcifications of 165-400 μm in size can be resolved using a MGD range of 0.3-1 mGy, respectively. In comparison to a General Electric GEN2 prototype DBT system (at MGD of 2.5 mGy), an increased CNR (by ∼10) for microcalcifications was observed using the Dexela 2923 MAM CMOS APS x-ray imager at a lower MGD (2.0 mGy). The Dexela 2923 MAM CMOS APS x-ray imager is capable to achieve a high imaging performance at spatial frequencies up to 6.7 lp/mm. Microcalcifications of 165 μm are distinguishable based on reported data and their modeling results due to the small pixel pitch of 75 μm. At the same time, potential dose reduction is expected using the studied CMOS APS x-ray imager.
Investigation of statistical iterative reconstruction for dedicated breast CT
Makeev, Andrey; Glick, Stephen J.
2013-01-01
Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue. Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters. Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose. Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose. PMID:23927318
The Expansion of Clusters of Galaxies
1961-01-01
investigators, currently we have usable data for a number of other clusters and groups. It is true that, with the exception of the Virgo Cluster , in each case...progress. Throughout this paper , the term "system of galaxies" is used as a synonym of the term " cluster " appearing in the theory of the spatial...mentioned at the beginning of the paper . Whether these outliers should be treated as members of the Coma Cluster or not is a subjective matter and
Patel, Nayana U; McKinney, Kristin; Kreidler, Sarah M; Bieker, Teresa M; Russ, Paul; Roberts, Katherine; Glueck, Deborah H; Albuja-Cruz, Maria; Klopper, Joshua; Haugen, Bryan R
2016-01-01
To identify sonographic features of cervical lymph nodes (LNs) that are associated with papillary thyroid cancer (PTC) and to develop a prediction model for classifying nodes as metastatic or benign. This retrospective study included the records of postthyroidectomy patients with PTC who had undergone cervical ultrasound and LN biopsy. LN location, size, shape, hilum, echopattern, Doppler flow, and microcalcifications were assessed. Model selection was used to identify features associated with malignant LNs and to build a predictive, binary-outcome, generalized linear mixed model. A cross-validated receiver operating characteristic analysis was conducted to assess the accuracy of the model for classifying metastatic nodes. We analyzed records from 71 LNs (23 metastatic) in 44 patients (16 with PTC). The predictive model included a nonhomogeneous echopattern (odds ratio [OR], 5.73; 95% confidence interval [CI], 1.07-30.74; p = 0.04), microcalcifications (OR, 4.91; 95% CI, 0.91-26.54; p = 0.06), and volume (OR, 2.57; 95% CI, 0.66-9.99; p = 0.16) as predictors. The model had an area under the curve of 0.74 (95% CI, 0.60-0.85), sensitivity of 65% (95% CI, 50% to 78%), and specificity of 85% (95% CI, 73% to 94%) at the Youden optimal cut point of 0.38. Nonhomogeneous echopattern, microcalcifications, and node volume were predictive of malignant LNs in patients with PTC. A larger sample is needed to validate this model. © 2015 Wiley Periodicals, Inc.
Zhao, C; Konstantinidis, A C; Zheng, Y; Anaxagoras, T; Speller, R D; Kanicki, J
2015-12-07
Wafer-scale CMOS active pixel sensors (APSs) have been developed recently for x-ray imaging applications. The small pixel pitch and low noise are very promising properties for medical imaging applications such as digital breast tomosynthesis (DBT). In this work, we evaluated experimentally and through modeling the imaging properties of a 50 μm pixel pitch CMOS APS x-ray detector named DynAMITe (Dynamic Range Adjustable for Medical Imaging Technology). A modified cascaded system model was developed for CMOS APS x-ray detectors by taking into account the device nonlinear signal and noise properties. The imaging properties such as modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) were extracted from both measurements and the nonlinear cascaded system analysis. The results show that the DynAMITe x-ray detector achieves a high spatial resolution of 10 mm(-1) and a DQE of around 0.5 at spatial frequencies <1 mm(-1). In addition, the modeling results were used to calculate the image signal-to-noise ratio (SNRi) of microcalcifications at various mean glandular dose (MGD). For an average breast (5 cm thickness, 50% glandular fraction), 165 μm microcalcifications can be distinguished at a MGD of 27% lower than the clinical value (~1.3 mGy). To detect 100 μm microcalcifications, further optimizations of the CMOS APS x-ray detector, image aquisition geometry and image reconstruction techniques should be considered.
Sund, T; Olsen, J B
2006-09-01
To investigate whether sliding window adaptive histogram equalization (SWAHE) of digital mammograms improves the detection of simulated calcifications, as compared to images normalized by global histogram equalization (GHE). Direct digital mammograms were obtained from mammary tissue phantoms superimposed with different frames. Each frame was divided into forty squares by a wire mesh, and contained granular calcifications randomly positioned in about 50% of the squares. Three radiologists read the mammograms on a display monitor. They classified their confidence in the presence of microcalcifications in each square on a scale of 1 to 5. Images processed with GHE were first read and used as a reference. In a later session, the same images processed with SWAHE were read. The results were compared using ROC methodology. When the total areas AZ were compared, the results were completely equivocal. When comparing the high-specificity partial ROC area AZ,0.2 below false-positive fraction (FPF) 0.20, two of the three observers performed best with the images processed with SWAHE. The difference was not statistically significant. When the reader's confidence threshold in malignancy is set at a high level, increasing the contrast of mammograms with SWAHE may enhance the visibility of microcalcifications without adversely affecting the false-positive rate. When the reader's confidence threshold is set at a low level, the effect of SWAHE is an increase of false positives. Further investigation is needed to confirm the validity of the conclusions.
The impact of baryons on massive galaxy clusters: halo structure and cluster mass estimates
NASA Astrophysics Data System (ADS)
Henson, Monique A.; Barnes, David J.; Kay, Scott T.; McCarthy, Ian G.; Schaye, Joop
2017-03-01
We use the BAHAMAS (BAryons and HAloes of MAssive Systems) and MACSIS (MAssive ClusterS and Intercluster Structures) hydrodynamic simulations to quantify the impact of baryons on the mass distribution and dynamics of massive galaxy clusters, as well as the bias in X-ray and weak lensing mass estimates. These simulations use the subgrid physics models calibrated in the BAHAMAS project, which include feedback from both supernovae and active galactic nuclei. They form a cluster population covering almost two orders of magnitude in mass, with more than 3500 clusters with masses greater than 1014 M⊙ at z = 0. We start by characterizing the clusters in terms of their spin, shape and density profile, before considering the bias in both weak lensing and hydrostatic mass estimates. Whilst including baryonic effects leads to more spherical, centrally concentrated clusters, the median weak lensing mass bias is unaffected by the presence of baryons. In both the dark matter only and hydrodynamic simulations, the weak lensing measurements underestimate cluster masses by ≈10 per cent for clusters with M200 ≤ 1015 M⊙ and this bias tends to zero at higher masses. We also consider the hydrostatic bias when using both the true density and temperature profiles, and those derived from X-ray spectroscopy. When using spectroscopic temperatures and densities, the hydrostatic bias decreases as a function of mass, leading to a bias of ≈40 per cent for clusters with M500 ≥ 1015 M⊙. This is due to the presence of cooler gas in the cluster outskirts. Using mass weighted temperatures and the true density profile reduces this bias to 5-15 per cent.
X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vedantham, Srinivasan; Karellas, Andrew
Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n= 1 -{delta}+i {beta}. The real part of the refractive index, specifically the refractive index decrement ({delta}), over the energy range of 5-50 keV were determined using XOP software (version 2.3, Europeanmore » Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine {delta}. At each x-ray photon energy, the absolute percent difference in {delta} between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient {mu}, and hence {beta}, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the {delta} of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the {mu} of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the {delta} of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of {mu}. Polymethyl methacrylate, a commonly used tissue substitute, exhibited {delta} greater than fibroglandular tissue by {approx}12%. The A-150 plastic closely approximated the skin. Several materials exhibited {delta} between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between {delta} and {mu} for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the {delta} and {mu} of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited {delta} greater than calcium hydroxyapatite by {approx}23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Chumin; Kanicki, Jerzy, E-mail: kanicki@eecs.umich.edu; Konstantinidis, Anastasios C.
Purpose: Large area x-ray imagers based on complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology have been proposed for various medical imaging applications including digital breast tomosynthesis (DBT). The low electronic noise (50–300 e{sup −}) of CMOS APS x-ray imagers provides a possible route to shrink the pixel pitch to smaller than 75 μm for microcalcification detection and possible reduction of the DBT mean glandular dose (MGD). Methods: In this study, imaging performance of a large area (29 × 23 cm{sup 2}) CMOS APS x-ray imager [Dexela 2923 MAM (PerkinElmer, London)] with a pixel pitch of 75 μm was characterizedmore » and modeled. The authors developed a cascaded system model for CMOS APS x-ray imagers using both a broadband x-ray radiation and monochromatic synchrotron radiation. The experimental data including modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were theoretically described using the proposed cascaded system model with satisfactory consistency to experimental results. Both high full well and low full well (LFW) modes of the Dexela 2923 MAM CMOS APS x-ray imager were characterized and modeled. The cascaded system analysis results were further used to extract the contrast-to-noise ratio (CNR) for microcalcifications with sizes of 165–400 μm at various MGDs. The impact of electronic noise on CNR was also evaluated. Results: The LFW mode shows better DQE at low air kerma (K{sub a} < 10 μGy) and should be used for DBT. At current DBT applications, air kerma (K{sub a} ∼ 10 μGy, broadband radiation of 28 kVp), DQE of more than 0.7 and ∼0.3 was achieved using the LFW mode at spatial frequency of 0.5 line pairs per millimeter (lp/mm) and Nyquist frequency ∼6.7 lp/mm, respectively. It is shown that microcalcifications of 165–400 μm in size can be resolved using a MGD range of 0.3–1 mGy, respectively. In comparison to a General Electric GEN2 prototype DBT system (at MGD of 2.5 mGy), an increased CNR (by ∼10) for microcalcifications was observed using the Dexela 2923 MAM CMOS APS x-ray imager at a lower MGD (2.0 mGy). Conclusions: The Dexela 2923 MAM CMOS APS x-ray imager is capable to achieve a high imaging performance at spatial frequencies up to 6.7 lp/mm. Microcalcifications of 165 μm are distinguishable based on reported data and their modeling results due to the small pixel pitch of 75 μm. At the same time, potential dose reduction is expected using the studied CMOS APS x-ray imager.« less
Investigation of statistical iterative reconstruction for dedicated breast CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makeev, Andrey; Glick, Stephen J.
2013-08-15
Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images weremore » compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.« less
X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials1
Vedantham, Srinivasan; Karellas, Andrew
2013-01-01
Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n = 1 − δ + i β. The real part of the refractive index, specifically the refractive index decrement (δ), over the energy range of 5–50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine δ. At each x-ray photon energy, the absolute percent difference in δ between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient μ, and hence β, was considered to be best representative of that breast tissue. Results: Over the energy range of 5–50 keV, while the δ of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the μ of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the δ of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of μ. Polymethyl methacrylate, a commonly used tissue substitute, exhibited δ greater than fibroglandular tissue by ∼12%. The A-150 plastic closely approximated the skin. Several materials exhibited δ between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between δ and μ for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the δ and μ of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited δ greater than calcium hydroxyapatite by ∼23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications. PMID:23556900
X-ray-induced acoustic computed tomography for 3D breast imaging: A simulation study.
Tang, Shanshan; Yang, Kai; Chen, Yong; Xiang, Liangzhong
2018-04-01
The objective of this study is to demonstrate the feasibility of x-ray-induced acoustic computed tomography (XACT) for early breast un-palpable microcalcification (μCa) detection in three dimensions (3D). The proposed technique provides the true 3D imaging for breast volume which overcomes the disadvantage of the tissue superposition in mammography. A 3D breast digital phantom was rendered from two-dimensional (2D) breast CT slices. Three different tissue types, including the skin, adipose tissue, and glandular tissue, were labeled in the 3D breast phantom. μCas were manually embedded in different locations inside the breast phantom. For each tissue type, the initial pressure rise caused by the x-ray-induced acoustic (XA) effect was calculated according to its themoacoustic properties. The XA wave's propagation from the point of generation and its detection by ultrasound detector array were simulated by Matlab K-Wave toolbox. The 3D breast XACT volume with μCa was acquired without tissue superposition, and the system was characterized by μCas placed at different locations. The simulation results illustrated that the proposed breast XACT system has the ability to show the μCa cluster in 3D without any tissue superposition. Meanwhile, μCa as small as 100 μm in size can be detected with high imaging contrast, high signal to noise ratio (SNR), and high contrast to noise ratio (CNR). The dose required by the proposed XACT configuration was calculated to be 0.4 mGy for a 4.5 cm-thick compressed breast. This is one-tenth of the dose level of a typical two-view mammography for a breast with the same compression thickness. The initial exploration for the feasibility of 3D breast XACT has been conducted in this study. The system feasibility and characterization were illustrated through a 3D breast phantom and simulation works. The 3D breast XACT with the proposed system configuration has great potential to be applied as a low-dose screening and diagnostic technique for early un-palpable lesion in the breast. © 2018 American Association of Physicists in Medicine.
State estimation and prediction using clustered particle filters.
Lee, Yoonsang; Majda, Andrew J
2016-12-20
Particle filtering is an essential tool to improve uncertain model predictions by incorporating noisy observational data from complex systems including non-Gaussian features. A class of particle filters, clustered particle filters, is introduced for high-dimensional nonlinear systems, which uses relatively few particles compared with the standard particle filter. The clustered particle filter captures non-Gaussian features of the true signal, which are typical in complex nonlinear dynamical systems such as geophysical systems. The method is also robust in the difficult regime of high-quality sparse and infrequent observations. The key features of the clustered particle filtering are coarse-grained localization through the clustering of the state variables and particle adjustment to stabilize the method; each observation affects only neighbor state variables through clustering and particles are adjusted to prevent particle collapse due to high-quality observations. The clustered particle filter is tested for the 40-dimensional Lorenz 96 model with several dynamical regimes including strongly non-Gaussian statistics. The clustered particle filter shows robust skill in both achieving accurate filter results and capturing non-Gaussian statistics of the true signal. It is further extended to multiscale data assimilation, which provides the large-scale estimation by combining a cheap reduced-order forecast model and mixed observations of the large- and small-scale variables. This approach enables the use of a larger number of particles due to the computational savings in the forecast model. The multiscale clustered particle filter is tested for one-dimensional dispersive wave turbulence using a forecast model with model errors.
State estimation and prediction using clustered particle filters
Lee, Yoonsang; Majda, Andrew J.
2016-01-01
Particle filtering is an essential tool to improve uncertain model predictions by incorporating noisy observational data from complex systems including non-Gaussian features. A class of particle filters, clustered particle filters, is introduced for high-dimensional nonlinear systems, which uses relatively few particles compared with the standard particle filter. The clustered particle filter captures non-Gaussian features of the true signal, which are typical in complex nonlinear dynamical systems such as geophysical systems. The method is also robust in the difficult regime of high-quality sparse and infrequent observations. The key features of the clustered particle filtering are coarse-grained localization through the clustering of the state variables and particle adjustment to stabilize the method; each observation affects only neighbor state variables through clustering and particles are adjusted to prevent particle collapse due to high-quality observations. The clustered particle filter is tested for the 40-dimensional Lorenz 96 model with several dynamical regimes including strongly non-Gaussian statistics. The clustered particle filter shows robust skill in both achieving accurate filter results and capturing non-Gaussian statistics of the true signal. It is further extended to multiscale data assimilation, which provides the large-scale estimation by combining a cheap reduced-order forecast model and mixed observations of the large- and small-scale variables. This approach enables the use of a larger number of particles due to the computational savings in the forecast model. The multiscale clustered particle filter is tested for one-dimensional dispersive wave turbulence using a forecast model with model errors. PMID:27930332
Classification of cirrhotic liver in Gadolinium-enhanced MR images
NASA Astrophysics Data System (ADS)
Lee, Gobert; Uchiyama, Yoshikazu; Zhang, Xuejun; Kanematsu, Masayuki; Zhou, Xiangrong; Hara, Takeshi; Kato, Hiroki; Kondo, Hiroshi; Fujita, Hiroshi; Hoshi, Hiroaki
2007-03-01
Cirrhosis of the liver is characterized by the presence of widespread nodules and fibrosis in the liver. The fibrosis and nodules formation causes distortion of the normal liver architecture, resulting in characteristic texture patterns. Texture patterns are commonly analyzed with the use of co-occurrence matrix based features measured on regions-of-interest (ROIs). A classifier is subsequently used for the classification of cirrhotic or non-cirrhotic livers. Problem arises if the classifier employed falls into the category of supervised classifier which is a popular choice. This is because the 'true disease states' of the ROIs are required for the training of the classifier but is, generally, not available. A common approach is to adopt the 'true disease state' of the liver as the 'true disease state' of all ROIs in that liver. This paper investigates the use of a nonsupervised classifier, the k-means clustering method in classifying livers as cirrhotic or non-cirrhotic using unlabelled ROI data. A preliminary result with a sensitivity and specificity of 72% and 60%, respectively, demonstrates the feasibility of using the k-means non-supervised clustering method in generating a characteristic cluster structure that could facilitate the classification of cirrhotic and non-cirrhotic livers.
Histopathology findings of non-mass cancers on breast ultrasound.
Kim, Hye Rin; Jung, Hae Kyoung
2018-06-01
There is little research done on non-mass cancers (NMCs) on breast ultrasound (US). To evaluate large-sectional histopathology findings of NMCs on breast US. The mammographic and histopathology features of biopsy proven 36 breast cancers which showed pure non-mass lesions on US were retrospectively reviewed. The most common mammographic finding was microcalcification (23/35, 65.7%); fine pleomorphic microcalcification was predominant (18/23, 78.3%). The main tumor type was pure ductal carcinoma in situ (DCIS) (14/36, 38.9%) and DCIS with micro- or minimal invasion (11/36, 30.6%). Among the 25 DCIS, histologic grade was high in 15 (60.0%) and intermediate in nine (36%); comedo necrosis was seen in 17 (68%). Immunohistochemical analysis was available in 27 lesions and showed HER2-overexpression in 12 (44.4%) and triple-negative in two (7.4%). According to our limited patient sample, NMCs on breast US were mainly associated with high-grade DCIS.
Detection method of visible and invisible nipples on digital breast tomosynthesis
NASA Astrophysics Data System (ADS)
Chae, Seung-Hoon; Jeong, Ji-Wook; Lee, Sooyeul; Chae, Eun Young; Kim, Hak Hee; Choi, Young-Wook
2015-03-01
Digital Breast Tomosynthesis(DBT) with 3D breast image can improve detection sensitivity of breast cancer more than 2D mammogram on dense breast. The nipple location information is needed to analyze DBT. The nipple location is invaluable information in registration and as a reference point for classifying mass or micro-calcification clusters. Since there are visible nipple and invisible nipple in 2D mammogram or DBT, the nipple detection of breast must be possible to detect visible and invisible nipple of breast. The detection method of visible nipple using shape information of nipple is simple and highly efficient. However, it is difficult to detect invisible nipple because it doesn't have prominent shape. Mammary glands in breast connect nipple, anatomically. The nipple location is detected through analyzing location of mammary glands in breast. In this paper, therefore, we propose a method to detect the nipple on a breast, which has a visible or invisible nipple using changes of breast area and mammary glands, respectively. The result shows that our proposed method has average error of 2.54+/-1.47mm.
Mesurolle, Benoît; Ceccarelli, Joan; Karp, Igor; Sun, Simon; El-Khoury, Mona
2014-02-01
Active ingredients in antiperspirants - namely, aluminum-based complexes - can produce radiopaque particles on mammography, mimicking microcalcifications. The present study was designed to investigate whether the appearance of antiperspirant induced radiopaque particles observed on mammograms is dependent on the percentage of aluminum-based complexes in antiperspirants and/or on their mode of application. A total of 43 antiperspirants with aluminum-based complex percentages ranging between 16% and 25% were tested. Each antiperspirant was applied to a single use plastic shield and then placed on an ultrasound gel pad, simulating breast tissue. Two experiments were performed, comparing antiperspirants based on (1) their percentage of aluminum-based complexes (20 antiperspirants) and (2) their mode of applications (solid, gel, and roll-on) (26 antiperspirants). Two experienced, blinded radiologists read images produced in consensus and assessed the appearance of radiopaque particles based on their density and shape. In experiment 1, there was no statistically significant association between the percent aluminum composition of invisible solid antiperspirants and the density or shape of the radiopaque particles (p-values>0.05). In experiment 2, there was a statistically significant association between the shape of the radiopaque particles and the mode of application of the antiperspirant (p-value=0.0015). Our study suggests that the mammographic appearance of the radiopaque antiperspirant particles is not related to their percent composition of aluminum complexes. However, their mode of application appears to influence the shape of radiopaque particles, solid antiperspirants mimicking microcalcifications the most and roll-on antiperspirants the least. Copyright © 2013. Published by Elsevier Ireland Ltd.
Kebir, Sied; Khurshid, Zain; Gaertner, Florian C; Essler, Markus; Hattingen, Elke; Fimmers, Rolf; Scheffler, Björn; Herrlinger, Ulrich; Bundschuh, Ralph A; Glas, Martin
2017-01-31
Timely detection of pseudoprogression (PSP) is crucial for the management of patients with high-grade glioma (HGG) but remains difficult. Textural features of O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography (FET-PET) mirror tumor uptake heterogeneity; some of them may be associated with tumor progression. Fourteen patients with HGG and suspected of PSP underwent FET-PET imaging. A set of 19 conventional and textural FET-PET features were evaluated and subjected to unsupervised consensus clustering. The final diagnosis of true progression vs. PSP was based on follow-up MRI using RANO criteria. Three robust clusters have been identified based on 10 predominantly textural FET-PET features. None of the patients with PSP fell into cluster 2, which was associated with high values for textural FET-PET markers of uptake heterogeneity. Three out of 4 patients with PSP were assigned to cluster 3 that was largely associated with low values of textural FET-PET features. By comparison, tumor-to-normal brain ratio (TNRmax) at the optimal cutoff 2.1 was less predictive of PSP (negative predictive value 57% for detecting true progression, p=0.07 vs. 75% with cluster 3, p=0.04). Clustering based on textural O-(2-[18F]fluoroethyl)-L-tyrosine PET features may provide valuable information in assessing the elusive phenomenon of pseudoprogression.
NASA Technical Reports Server (NTRS)
Prosser, Charles F.
1993-01-01
The results of a combined astrometric, photometric, and spectroscopic program to identify members of the open cluster IC 4665 are presented. Numerous new proper motion/photometric candidate members and at least 23 M dwarfs with H-alpha emission have been identified. A reanalysis of IC 4665 age using different methods yields conflicting results ranging from about 3 X 10 exp 7 yr to the age of the Pleiades. This study provides a list of candidate cluster members in the intermediate and low-mass regime of this cluster. Future spectroscopic observations of these candidates should eventually identify true cluster members.
Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim
2014-01-01
There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049
Zhang, Xiaohua Douglas; Yang, Xiting Cindy; Chung, Namjin; Gates, Adam; Stec, Erica; Kunapuli, Priya; Holder, Dan J; Ferrer, Marc; Espeseth, Amy S
2006-04-01
RNA interference (RNAi) high-throughput screening (HTS) experiments carried out using large (>5000 short interfering [si]RNA) libraries generate a huge amount of data. In order to use these data to identify the most effective siRNAs tested, it is critical to adopt and develop appropriate statistical methods. To address the questions in hit selection of RNAi HTS, we proposed a quartile-based method which is robust to outliers, true hits and nonsymmetrical data. We compared it with the more traditional tests, mean +/- k standard deviation (SD) and median +/- 3 median of absolute deviation (MAD). The results suggested that the quartile-based method selected more hits than mean +/- k SD under the same preset error rate. The number of hits selected by median +/- k MAD was close to that by the quartile-based method. Further analysis suggested that the quartile-based method had the greatest power in detecting true hits, especially weak or moderate true hits. Our investigation also suggested that platewise analysis (determining effective siRNAs on a plate-by-plate basis) can adjust for systematic errors in different plates, while an experimentwise analysis, in which effective siRNAs are identified in an analysis of the entire experiment, cannot. However, experimentwise analysis may detect a cluster of true positive hits placed together in one or several plates, while platewise analysis may not. To display hit selection results, we designed a specific figure called a plate-well series plot. We thus suggest the following strategy for hit selection in RNAi HTS experiments. First, choose the quartile-based method, or median +/- k MAD, for identifying effective siRNAs. Second, perform the chosen method experimentwise on transformed/normalized data, such as percentage inhibition, to check the possibility of hit clusters. If a cluster of selected hits are observed, repeat the analysis based on untransformed data to determine whether the cluster is due to an artifact in the data. If no clusters of hits are observed, select hits by performing platewise analysis on transformed data. Third, adopt the plate-well series plot to visualize both the data and the hit selection results, as well as to check for artifacts.
Clustering redshift distributions for the Dark Energy Survey
NASA Astrophysics Data System (ADS)
Helsby, Jennifer
Accurate determination of photometric redshifts and their errors is critical for large scale structure and weak lensing studies for constraining cosmology from deep, wide imaging surveys. Current photometric redshift methods suffer from bias and scatter due to incomplete training sets. Exploiting the clustering between a sample of galaxies for which we have spectroscopic redshifts and a sample of galaxies for which the redshifts are unknown can allow us to reconstruct the true redshift distribution of the unknown sample. Here we use this method in both simulations and early data from the Dark Energy Survey (DES) to determine the true redshift distributions of galaxies in photometric redshift bins. We find that cross-correlating with the spectroscopic samples currently used for training provides a useful test of photometric redshifts and provides reliable estimates of the true redshift distribution in a photometric redshift bin. We discuss the use of the cross-correlation method in validating template- or learning-based approaches to redshift estimation and its future use in Stage IV surveys.
Rosenthal, Mariana; Johnson, Christopher J; Scoppa, Steve; Carter, Kris
2016-01-01
Investigations of suspected cancer clusters are resource intensive and rarely identify true clusters: among 428 publicly reported US investigations during 1990-2011, only 1 etiologic cluster was identified. In 2013, the Cancer Data Registry of Idaho (CDRI) was contacted regarding a suspected cancer cluster at a worksite (Cluster A) and among an occupational cohort (Cluster B). We investigated to determine whether these were true clusters. We derived investigation cohorts for Cluster A from facility-provided employee records and for Cluster B from professional licensing records. We used Registry PlusTM Link Plus to conduct probabilistic linkage of cohort members to the CDRI registry and completed matching through manual review by using LexisNexis®, Accurint®, and the Social Security Death Index. We calculated standardized incidence ratios (SIR) using the MP-SIR session type in SEER*Stat and Idaho and US referent populations. For Cluster A, we identified 34 cancer cases during 9,689 person-years; compared with Idaho and US rates, 95 percent CIs for SIRs included 1.0 for 24 of 24 primary site categories. For Cluster B, we identified 78 cancer cases during 15,154 person-years; compared with Idaho rates, 95 percent CI for SIRs included 1.0 for 23 of 24 primary site categories and was less than 1.0 for lung and bronchus cancers, and compared with US rates, 95 percent CI for SIRs included 1.0 for 22 of 24 primary site categories and was less than 1.0 for lung and bronchus and colorectal cancers. We identified no statistically significant excess in cancer incidence in either cohort. SEER*Stat's MP-SIR is an efficient tool for performing SIR assessments, a Centers for Disease Control and Prevention/Council of State and Territorial Epidemiologists-recommended step when investigating suspected cancer clusters.
Kebir, Sied; Khurshid, Zain; Gaertner, Florian C.; Essler, Markus; Hattingen, Elke; Fimmers, Rolf; Scheffler, Björn; Herrlinger, Ulrich; Bundschuh, Ralph A.; Glas, Martin
2017-01-01
Rationale Timely detection of pseudoprogression (PSP) is crucial for the management of patients with high-grade glioma (HGG) but remains difficult. Textural features of O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography (FET-PET) mirror tumor uptake heterogeneity; some of them may be associated with tumor progression. Methods Fourteen patients with HGG and suspected of PSP underwent FET-PET imaging. A set of 19 conventional and textural FET-PET features were evaluated and subjected to unsupervised consensus clustering. The final diagnosis of true progression vs. PSP was based on follow-up MRI using RANO criteria. Results Three robust clusters have been identified based on 10 predominantly textural FET-PET features. None of the patients with PSP fell into cluster 2, which was associated with high values for textural FET-PET markers of uptake heterogeneity. Three out of 4 patients with PSP were assigned to cluster 3 that was largely associated with low values of textural FET-PET features. By comparison, tumor-to-normal brain ratio (TNRmax) at the optimal cutoff 2.1 was less predictive of PSP (negative predictive value 57% for detecting true progression, p=0.07 vs. 75% with cluster 3, p=0.04). Principal Conclusions Clustering based on textural O-(2-[18F]fluoroethyl)-L-tyrosine PET features may provide valuable information in assessing the elusive phenomenon of pseudoprogression. PMID:28030820
Fernández-García, P; Marco-Doménech, S F; Lizán-Tudela, L; Ibáñez-Gual, M V; Navarro-Ballester, A; Casanovas-Feliu, E
To determine the cost effectiveness of breast biopsy by 9G vacuum-assisted guided by vertical stereotaxy or ultrasonography in comparison with breast biopsy by 14G core-needle biopsy and surgical biopsy. We analyzed a total of 997 biopsies (181 vacuum-assisted, 626 core, and 190 surgical biopsies). We calculated the total costs (indirect and direct) of the three types of biopsy. We did not calculate intangible costs. We measured the percentage of correct diagnoses obtained with each technique. To identify the most cost-effective option, we calculated the mean ratios for the three types of biopsies. Total costs were €225.09 for core biopsy, €638.90 for vacuum-assisted biopsy, and €1780.01 for surgical biopsy. The overall percentage of correct diagnoses was 91.81% for core biopsy, 94.03% for vacuum-assisted biopsy, and 100% for surgical biopsy; however, these differences did not reach statistical significance (p=0.3485). For microcalcifications, the percentage of correct diagnoses was 50% for core biopsy and 96.77% for vacuum-assisted biopsy (p<0.0001). For nodules, there were no significant differences among techniques. The mean cost-effectiveness ratio considering all lesions was 2.45 for core biopsy, 6.79 for vacuum-assisted biopsy, and 17.80 for surgical biopsy. Core biopsy was the dominant option for the diagnosis of suspicious breast lesions in general. However, in cases with microcalcifications, the low percentage of correct diagnoses achieved by core biopsy (50%) advises against its use in this context, where vacuum-assisted biopsy would be the technique of choice because it is more cost-effective than surgical biopsy, the other technique indicated for biopsying microcalcifications. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Introducing DeBRa: a detailed breast model for radiological studies
NASA Astrophysics Data System (ADS)
Ma, Andy K. W.; Gunn, Spencer; Darambara, Dimitra G.
2009-07-01
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the Cooper ligaments and the pectoral muscle. The fibroglandular tissues are also modelled realistically. In addition, abnormalities such as microcalcifications, irregular tumours and spiculated tumours are inserted into the phantom. Existing sophisticated breast models require specialized simulation codes. Unlike its predecessors, DeBRa has elemental compositions and densities incorporated into its voxels including those of the explicitly modelled anatomical structures and the noise-like fibroglandular tissues. The voxel dimensions are specified as needed by any study and the microcalcifications are embedded into the voxels so that the microcalcification sizes are not limited by the voxel dimensions. Therefore, DeBRa works with general-purpose Monte Carlo codes. Furthermore, general-purpose Monte Carlo codes allow different types of imaging modalities and detector characteristics to be simulated with ease. DeBRa is a versatile and multipurpose model specifically designed for both x-ray and γ-ray imaging studies.
Sim, Y T; Litherland, J; Lindsay, E; Hendry, P; Brauer, K; Dobson, H; Cordiner, C; Gagliardi, T; Smart, L
2015-05-01
To identify factors affecting upgrade rates from B5a (non-invasive) preoperative core biopsies to invasive disease at surgery and ways to improve screening performance. This was a retrospective analysis of 1252 cases of B5a biopsies across all six Scottish Breast Screening Programmes (BSPs), ranging between 2004 and 2012. Final surgical histopathology was correlated with radiological and biopsy factors. Data were analysed using basic Microsoft Excel and standard Chi-squared test used for evaluating statistical significance. B5a upgrade rates for the units ranged from 19.2% to 29.2%, with an average of 23.6%. Mean sizes of invasive tumours were small (3-11 mm). The upgrade rate was significantly higher for cases where the main mammographic abnormality was mass, distortion, or asymmetry, compared with micro-calcification alone (33.2% versus 21.7%, p = 0.0004). The upgrade rate was significantly lower with the use of large-volume vacuum-assisted biopsy (VAB) devices than 14 G core needles (19.9% versus 26%, p = 0.013); in stereotactic than ultrasound-guided biopsies (21.2% versus 36.1%, p < 0.001). Heterogeneity of data from different centres limited evaluation of other potential factors. Upgrade rates are lower for cases with micro-calcification as the sole mammographic feature with the use of VAB devices. Nevertheless, there is variation in practice across Scottish BSPs, including first-line biopsy technique and/or device; and it is of interest that a few centres maintain low upgrade rates despite not using VAB routinely for biopsy of micro-calcification. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Maxwell, Anthony J; Morris, Julie; Lim, Yit Y; Harake, MD Janick; Whiteside, Sigrid
2016-01-01
Objective: To compare the accuracy of 11-G vacuum-assisted biopsy (VAB) with 14-G core needle biopsy (CNB) to diagnose mammographic microcalcification (MM) and effect on surgical outcomes. Methods: Following ethical approval, VAB and CNB (control) were compared in a randomized prospective study for first-line diagnosis of MM and subsequent surgical outcomes in two breast-screening units. Participants gave written informed consent. Exclusions included comorbidity precluding surgery, prior ipsilateral breast cancer and lesions >40 mm requiring mastectomy as first surgical procedure. The final pathological diagnosis was compared with the initial biopsy result. Quality-of-life (QOL) questionnaires were administered at baseline, 2, 6 and 12 months. 110 participants were required to show a 25% improvement in diagnosis with VAB compared with CNB (90% power). Results: Eligibility was assessed for 787 cases; 129 females recalled from the National Health Service breast screening programme were randomized. Diagnostic accuracy of VAB was 86% and that of CNB was 84%. Using VAB, 2/14 (14.3%) cases upgraded from ductal carcinoma in situ to invasion at surgery and 3/19 (15.8%) using CNB. Following VAB 7/16 (44%) cases required repeat surgery vs 7/24 (29%) after CNB. Both groups recorded significant worsening of functional QOL measures and increased breast pain at follow-up. Conclusion: VAB and CNB were equally accurate at diagnosing MM, and no significant differences in surgical outcomes were observed. Advances in knowledge: The first randomized controlled study of VAB for diagnosis of microcalcification using digital mammography showed no difference in diagnostic accuracy of VAB and CNB, or in the proportion of participants needing repeat non-operative biopsy or second therapeutic operation to treat malignancy. PMID:26654214
Lalji, U C; Jeukens, C R L P N; Houben, I; Nelemans, P J; van Engen, R E; van Wylick, E; Beets-Tan, R G H; Wildberger, J E; Paulis, L E; Lobbes, M B I
2015-10-01
Contrast-enhanced spectral mammography (CESM) examination results in a low-energy (LE) and contrast-enhanced image. The LE appears similar to a full-field digital mammogram (FFDM). Our aim was to evaluate LE CESM image quality by comparing it to FFDM using criteria defined by the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services (EUREF). A total of 147 cases with both FFDM and LE images were independently scored by two experienced radiologists using these (20) EUREF criteria. Contrast detail measurements were performed using a dedicated phantom. Differences in image quality scores, average glandular dose, and contrast detail measurements between LE and FFDM were tested for statistical significance. No significant differences in image quality scores were observed between LE and FFDM images for 17 out of 20 criteria. LE scored significantly lower on one criterion regarding the sharpness of the pectoral muscle (p < 0.001), and significantly better on two criteria on the visualization of micro-calcifications (p = 0.02 and p = 0.034). Dose and contrast detail measurements did not reveal any physical explanation for these observed differences. Low-energy CESM images are non-inferior to FFDM images. From this perspective FFDM can be omitted in patients with an indication for CESM. • Low-energy CESM images are non-inferior to FFDM images. • Micro-calcifications are significantly more visible on LE CESM than on FFDM. • There is no physical explanation for this improved visibility of micro-calcifications. • There is no need for an extra FFDM when CESM is indicated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghammraoui, B; M Popescu, L; Badano, A
Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on amore » virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications.« less
Bennani-Baiti, Barbara; Bennani-Baiti, Nabila; Baltzer, Pascal A
2016-01-01
To evaluate the performance of MRI for diagnosis of breast cancer in non-calcified equivocal breast findings. We performed a systematic review and meta-analysis of peer-reviewed studies in PubMed from 01/01/1986 until 06/15/2015. Eligible were studies applying dynamic contrast-enhanced breast MRI as an adjunct to conventional imaging (mammography, ultrasound) to clarify equivocal findings without microcalcifications. Reference standard for MRI findings had to be established by histopathological sampling or imaging follow-up of at least 12 months. Number of true or false positives and negatives and other characteristics were extracted, and possible bias was determined using the QUADAS-2 applet. Statistical analyses included data pooling and heterogeneity testing. Fourteen out of 514 studies comprising 2,316 lesions met our inclusion criteria. Pooled diagnostic parameters were: sensitivity (99%, 95%-CI: 93-100%), specificity (89%, 95%-CI: 85-92%), PPV (56%, 95%-CI: 42-70%) and NPV (100%, 95%-CI: 99-100%). These estimates displayed significant heterogeneity (P<0.001). Breast MRI demonstrates an excellent diagnostic performance in case of non-calcified equivocal breast findings detected in conventional imaging. However, considering the substantial heterogeneity with regard to prevalence of malignancy, problem solving criteria need to be better defined.
Tanaka, Toyohiko; Nitta, Norihisa; Ohta, Shinichi; Kobayashi, Tsuyoshi; Kano, Akiko; Tsuchiya, Keiko; Murakami, Yoko; Kitahara, Sawako; Wakamiya, Makoto; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi
2009-12-01
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-μm-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages.
Junankar, Simon; Shay, Gemma; Jurczyluk, Julie; Ali, Naveid; Down, Jenny; Pocock, Nicholas; Parker, Andrew; Nguyen, Akira; Sun, Shuting; Kashemirov, Boris; McKenna, Charles E.; Croucher, Peter I.; Swarbrick, Alexander; Weilbaecher, Katherine; Phan, Tri Giang; Rogers, Michael J.
2014-01-01
Recent clinical trials have shown that bisphosphonate drugs improve breast cancer patient survival independent of their anti-resorptive effects on the skeleton. However, since bisphosphonates bind rapidly to bone mineral, the exact mechanisms of their anti-tumour action, particularly on cells outside of bone, remain unknown. Here we used real-time intravital two-photon microscopy to show extensive leakage of fluorescent bisphosphonate from the vasculature in 4T1 mouse mammary tumours, where it initially binds to areas of small, granular microcalcifications that are engulfed by tumour-associated macrophages (TAMs), but not tumour cells. Importantly, we also observed uptake of radiolabeled bisphosphonate in the primary breast tumour of a patient and showed the resected tumour to be infiltrated with TAMs and to contain similar granular microcalcifications. These data represent the first compelling in vivo evidence that bisphosphonates can target cells in tumours outside the skeleton and that their anti-tumour activity is likely to be mediated via TAMs. PMID:25312016
Characteristics of metastasis in the breast from extramammary malignancies.
Lee, Se Kyung; Kim, Wan Wook; Kim, Sung Hoon; Hur, Sung Mo; Kim, Sangmin; Choi, Jae Hyuck; Cho, Eun Yoon; Han, Soo Yeon; Hahn, Boo-Kyung; Choe, Jun-Ho; Kim, Jung-Han; Kim, Jee Soo; Lee, Jeong Eon; Nam, Seok Jin; Yang, Jung-Hyun
2010-02-01
Breast metastasis from extramammary neoplasm is rare. We present the cases of metastasis to the breast after review of results in one institute and we want to show the difference of previous report. The surgical and pathology databases of Samsung Medical Center from November 1994 to March 2009 were investigated to identify all patients with a diagnosis of metastasis to the breast. Thirty-three patients with breast metastases from extramammary neoplasm were studied. Gastric carcinoma was most common metastatic origin in this study. There were four cases with microcalcifications in their metastatic lesions. This is the first report of microcalcification of metastatic lesions to the breast from hepatocellular carcinoma and gastric cancer. Pathologic examination and considering known clinical history may be helpful to differentiate the primary breast cancer and metastatic cancer. Metastasis to the breast from an extramammary neoplasm usually indicates disseminated metastatic disease and a poor prognosis. An accurate diagnosis of breast metastases, differentiating primary from metastatic breast carcinoma, is important for proper management.
The Frontier Fields lens modelling comparison project
NASA Astrophysics Data System (ADS)
Meneghetti, M.; Natarajan, P.; Coe, D.; Contini, E.; De Lucia, G.; Giocoli, C.; Acebron, A.; Borgani, S.; Bradac, M.; Diego, J. M.; Hoag, A.; Ishigaki, M.; Johnson, T. L.; Jullo, E.; Kawamata, R.; Lam, D.; Limousin, M.; Liesenborgs, J.; Oguri, M.; Sebesta, K.; Sharon, K.; Williams, L. L. R.; Zitrin, A.
2017-12-01
Gravitational lensing by clusters of galaxies offers a powerful probe of their structure and mass distribution. Several research groups have developed techniques independently to achieve this goal. While these methods have all provided remarkably high-precision mass maps, particularly with exquisite imaging data from the Hubble Space Telescope (HST), the reconstructions themselves have never been directly compared. In this paper, we present for the first time a detailed comparison of methodologies for fidelity, accuracy and precision. For this collaborative exercise, the lens modelling community was provided simulated cluster images that mimic the depth and resolution of the ongoing HST Frontier Fields. The results of the submitted reconstructions with the un-blinded true mass profile of these two clusters are presented here. Parametric, free-form and hybrid techniques have been deployed by the participating groups and we detail the strengths and trade-offs in accuracy and systematics that arise for each methodology. We note in conclusion that several properties of the lensing clusters are recovered equally well by most of the lensing techniques compared in this study. For example, the reconstruction of azimuthally averaged density and mass profiles by both parametric and free-form methods matches the input models at the level of ∼10 per cent. Parametric techniques are generally better at recovering the 2D maps of the convergence and of the magnification. For the best-performing algorithms, the accuracy in the magnification estimate is ∼10 per cent at μtrue = 3 and it degrades to ∼30 per cent at μtrue ∼ 10.
NAS Requirements Checklist for Job Queuing/Scheduling Software
NASA Technical Reports Server (NTRS)
Jones, James Patton
1996-01-01
The increasing reliability of parallel systems and clusters of computers has resulted in these systems becoming more attractive for true production workloads. Today, the primary obstacle to production use of clusters of computers is the lack of a functional and robust Job Management System for parallel applications. This document provides a checklist of NAS requirements for job queuing and scheduling in order to make most efficient use of parallel systems and clusters for parallel applications. Future requirements are also identified to assist software vendors with design planning.
Levin-Rector, Alison; Wilson, Elisha L; Fine, Annie D; Greene, Sharon K
2015-02-01
Since the early 2000s, the Bureau of Communicable Disease of the New York City Department of Health and Mental Hygiene has analyzed reportable infectious disease data weekly by using the historical limits method to detect unusual clusters that could represent outbreaks. This method typically produced too many signals for each to be investigated with available resources while possibly failing to signal during true disease outbreaks. We made method refinements that improved the consistency of case inclusion criteria and accounted for data lags and trends and aberrations in historical data. During a 12-week period in 2013, we prospectively assessed these refinements using actual surveillance data. The refined method yielded 74 signals, a 45% decrease from what the original method would have produced. Fewer and less biased signals included a true citywide increase in legionellosis and a localized campylobacteriosis cluster subsequently linked to live-poultry markets. Future evaluations using simulated data could complement this descriptive assessment.
Experimentally determined spectral optimization for dedicated breast computed tomography.
Prionas, Nicolas D; Huang, Shih-Ying; Boone, John M
2011-02-01
The current study aimed to experimentally identify the optimal technique factors (x-ray tube potential and added filtration material/thickness) to maximize soft-tissue contrast, microcalcification contrast, and iodine contrast enhancement using cadaveric breast specimens imaged with dedicated breast computed tomography (bCT). Secondarily, the study aimed to evaluate the accuracy of phantom materials as tissue surrogates and to characterize the change in accuracy with varying bCT technique factors. A cadaveric breast specimen was acquired under appropriate approval and scanned using a prototype bCT scanner. Inserted into the specimen were cylindrical inserts of polyethylene, water, iodine contrast medium (iodixanol, 2.5 mg/ml), and calcium hydroxyapatite (100 mg/ml). Six x-ray tube potentials (50, 60, 70, 80, 90, and 100 kVp) and three different filters (0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn) were tested. For each set of technique factors, the intensity (linear attenuation coefficient) and noise were measured within six regions of interest (ROIs): Glandular tissue, adipose tissue, polyethylene, water, iodine contrast medium, and calcium hydroxyapatite. Dose-normalized contrast to noise ratio (CNRD) was measured for pairwise comparisons among the six ROIs. Regression models were used to estimate the effect of tube potential and added filtration on intensity, noise, and CNRD. Iodine contrast enhancement was maximized using 60 kVp and 0.2 mm Cu. Microcalcification contrast and soft-tissue contrast were maximized at 60 kVp. The 0.2 mm Cu filter achieved significantly higher CNRD for iodine contrast enhancement than the other two filters (p = 0.01), but microcalcification contrast and soft-tissue contrast were similar using the copper and aluminum filters. The average percent difference in linear attenuation coefficient, across all tube potentials, for polyethylene versus adipose tissue was 1.8%, 1.7%, and 1.3% for 0.2 mm Cu, 1.5 mm Al, and 0.2 mm Sn, respectively. For water versus glandular tissue, the average percent difference was 2.7%, 3.9%, and 4.2% for the three filter types. Contrast-enhanced bCT, using injected iodine contrast medium, may be optimized for maximum contrast of enhancing lesions at 60 kVp with 0.2 mm Cu filtration. Soft-tissue contrast and microcalcification contrast may also benefit from lower tube potentials (60 kVp). The linear attenuation coefficients of water and polyethylene slightly overestimate the values of their corresponding tissues, but the reported differences may serve as guidance for dosimetry and quality assurance using tissue equivalent phantoms.
Optimized Clustering Estimators for BAO Measurements Accounting for Significant Redshift Uncertainty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ross, Ashley J.; Banik, Nilanjan; Avila, Santiago
2017-05-15
We determine an optimized clustering statistic to be used for galaxy samples with significant redshift uncertainty, such as those that rely on photometric redshifts. To do so, we study the BAO information content as a function of the orientation of galaxy clustering modes with respect to their angle to the line-of-sight (LOS). The clustering along the LOS, as observed in a redshift-space with significant redshift uncertainty, has contributions from clustering modes with a range of orientations with respect to the true LOS. For redshift uncertaintymore » $$\\sigma_z \\geq 0.02(1+z)$$ we find that while the BAO information is confined to transverse clustering modes in the true space, it is spread nearly evenly in the observed space. Thus, measuring clustering in terms of the projected separation (regardless of the LOS) is an efficient and nearly lossless compression of the signal for $$\\sigma_z \\geq 0.02(1+z)$$. For reduced redshift uncertainty, a more careful consideration is required. We then use more than 1700 realizations of galaxy simulations mimicking the Dark Energy Survey Year 1 sample to validate our analytic results and optimized analysis procedure. We find that using the correlation function binned in projected separation, we can achieve uncertainties that are within 10 per cent of of those predicted by Fisher matrix forecasts. We predict that DES Y1 should achieve a 5 per cent distance measurement using our optimized methods. We expect the results presented here to be important for any future BAO measurements made using photometric redshift data.« less
Optimized clustering estimators for BAO measurements accounting for significant redshift uncertainty
NASA Astrophysics Data System (ADS)
Ross, Ashley J.; Banik, Nilanjan; Avila, Santiago; Percival, Will J.; Dodelson, Scott; Garcia-Bellido, Juan; Crocce, Martin; Elvin-Poole, Jack; Giannantonio, Tommaso; Manera, Marc; Sevilla-Noarbe, Ignacio
2017-12-01
We determine an optimized clustering statistic to be used for galaxy samples with significant redshift uncertainty, such as those that rely on photometric redshifts. To do so, we study the baryon acoustic oscillation (BAO) information content as a function of the orientation of galaxy clustering modes with respect to their angle to the line of sight (LOS). The clustering along the LOS, as observed in a redshift-space with significant redshift uncertainty, has contributions from clustering modes with a range of orientations with respect to the true LOS. For redshift uncertainty σz ≥ 0.02(1 + z), we find that while the BAO information is confined to transverse clustering modes in the true space, it is spread nearly evenly in the observed space. Thus, measuring clustering in terms of the projected separation (regardless of the LOS) is an efficient and nearly lossless compression of the signal for σz ≥ 0.02(1 + z). For reduced redshift uncertainty, a more careful consideration is required. We then use more than 1700 realizations (combining two separate sets) of galaxy simulations mimicking the Dark Energy Survey Year 1 (DES Y1) sample to validate our analytic results and optimized analysis procedure. We find that using the correlation function binned in projected separation, we can achieve uncertainties that are within 10 per cent of those predicted by Fisher matrix forecasts. We predict that DES Y1 should achieve a 5 per cent distance measurement using our optimized methods. We expect the results presented here to be important for any future BAO measurements made using photometric redshift data.
A microfluidic device for label-free, physical capture of circulating tumor cell-clusters
Sarioglu, A. Fatih; Aceto, Nicola; Kojic, Nikola; Donaldson, Maria C.; Zeinali, Mahnaz; Hamza, Bashar; Engstrom, Amanda; Zhu, Huili; Sundaresan, Tilak K.; Miyamoto, David T.; Luo, Xi; Bardia, Aditya; Wittner, Ben S.; Ramaswamy, Sridhar; Shioda, Toshi; Ting, David T.; Stott, Shannon L.; Kapur, Ravi; Maheswaran, Shyamala; Haber, Daniel A.; Toner, Mehmet
2015-01-01
Cancer cells metastasize through the bloodstream either as single migratory circulating tumor cells (CTCs) or as multicellular groupings (CTC-clusters). Existing technologies for CTC enrichment are designed primarily to isolate single CTCs, and while CTC-clusters are detectable in some cases, their true prevalence and significance remain to be determined. Here, we developed a microchip technology (Cluster-Chip) specifically designed to capture CTC-clusters independent of tumor-specific markers from unprocessed blood. CTC-clusters are isolated through specialized bifurcating traps under low shear-stress conditions that preserve their integrity and even two-cell clusters are captured efficiently. Using the Cluster-Chip, we identify CTC-clusters in 30–40% of patients with metastatic cancers of the breast, prostate and melanoma. RNA sequencing of CTC-clusters confirms their tumor origin and identifies leukocytes within the clusters as tissue-derived macrophages. Together, the development of a device for efficient capture of CTC-clusters will enable detailed characterization of their biological properties and role in cancer metastasis. PMID:25984697
IDENTIFICATION OF MEMBERS IN THE CENTRAL AND OUTER REGIONS OF GALAXY CLUSTERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Serra, Ana Laura; Diaferio, Antonaldo, E-mail: serra@ph.unito.it
2013-05-10
The caustic technique measures the mass of galaxy clusters in both their virial and infall regions and, as a byproduct, yields the list of cluster galaxy members. Here we use 100 galaxy clusters with mass M{sub 200} {>=} 10{sup 14} h {sup -1} M{sub Sun} extracted from a cosmological N-body simulation of a {Lambda}CDM universe to test the ability of the caustic technique to identify the cluster galaxy members. We identify the true three-dimensional members as the gravitationally bound galaxies. The caustic technique uses the caustic location in the redshift diagram to separate the cluster members from the interlopers. Wemore » apply the technique to mock catalogs containing 1000 galaxies in the field of view of 12 h {sup -1} Mpc on a side at the cluster location. On average, this sample size roughly corresponds to 180 real galaxy members within 3r{sub 200}, similar to recent redshift surveys of cluster regions. The caustic technique yields a completeness, the fraction of identified true members, f{sub c} = 0.95 {+-} 0.03, within 3r{sub 200}. The contamination, the fraction of interlopers in the observed catalog of members, increases from f{sub i}=0.020{sup +0.046}{sub -0.015} at r{sub 200} to f{sub i}=0.08{sup +0.11}{sub -0.05} at 3r{sub 200}. No other technique for the identification of the members of a galaxy cluster provides such large completeness and small contamination at these large radii. The caustic technique assumes spherical symmetry and the asphericity of the cluster is responsible for most of the spread of the completeness and the contamination. By applying the technique to an approximately spherical system obtained by stacking the individual clusters, the spreads decrease by at least a factor of two. We finally estimate the cluster mass within 3r{sub 200} after removing the interlopers: for individual clusters, the mass estimated with the virial theorem is unbiased and within 30% of the actual mass; this spread decreases to less than 10% for the spherically symmetric stacked cluster.« less
Automated selection of BI-RADS lesion descriptors for reporting calcifications in mammograms
NASA Astrophysics Data System (ADS)
Paquerault, Sophie; Jiang, Yulei; Nishikawa, Robert M.; Schmidt, Robert A.; D'Orsi, Carl J.; Vyborny, Carl J.; Newstead, Gillian M.
2003-05-01
We are developing an automated computer technique to describe calcifications in mammograms according to the BI-RADS lexicon. We evaluated this technique by its agreement with radiologists' description of the same lesions. Three expert mammographers reviewed our database of 90 cases of digitized mammograms containing clustered microcalcifications and described the calcifications according to BI-RADS. In our study, the radiologists used only 4 of the 5 calcification distribution descriptors and 5 of the 14 calcification morphology descriptors contained in BI-RADS. Our computer technique was therefore designed specifically for these 4 calcification distribution descriptors and 5 calcification morphology descriptors. For calcification distribution, 4 linear discriminant analysis (LDA) classifiers were developed using 5 computer-extracted features to produce scores of how well each descriptor describes a cluster. Similarly, for calcification morphology, 5 LDAs were designed using 10 computer-extracted features. We trained the LDAs using only the BI-RADS data reported by the first radiologist and compared the computer output to the descriptor data reported by all 3 radiologists (for the first radiologist, the leave-one-out method was used). The computer output consisted of the best calcification distribution descriptor and the best 2 calcification morphology descriptors. The results of the comparison with the data from each radiologist, respectively, were: for calcification distribution, percent agreement, 74%, 66%, and 73%, kappa value, 0.44, 0.36, and 0.46; for calcification morphology, percent agreement, 83%, 77%, and 57%, kappa value, 0.78, 0.70, and 0.44. These results indicate that the proposed computer technique can select BI-RADS descriptors in good agreement with radiologists.
The Role of Binarity in the Angular Momentum Evolution of M Dwarfs
NASA Astrophysics Data System (ADS)
Stauffer, John; Rebull, Luisa; K2 clusters team
2018-01-01
We have analysed K2 light curves for of order a thousand low mass stars in each of the 8 Myr old Upper Sco association, the 125 Myr age Pleiades open cluster and the ~700 Myr old Praesepe cluster. A very large fraction of these stars show well-determined rotation periods with K2, and where the star is a binary, we usually are able to determine periods for both stars. In Upper Sco, where there are ~150 M dwarf binaries with K2 light curves, the binary stars have periods that are much shorter on average and much closer to each other than would be true if drawn at random from the Upper Sco M dwarf single stars. The same is true in the Pleiades,though the size of the differences from the single M dwarf population is smaller. By Praesepe age, the M dwarf binaries are still somewhat rapidly rotating but their period differences are not significantly different from what would be true if drawn by chance from the singles.
Deducing the Milky Way's Massive Cluster Population
NASA Astrophysics Data System (ADS)
Hanson, M. M.; Popescu, B.; Larsen, S. S.; Ivanov, V. D.
2010-11-01
Recent near-infrared surveys of the galactic plane have been used to identify new massive cluster candidates. Follow up study indicates about half are not true, gravitationally-bound clusters. These false positives are created by high density fields of unassociated stars, often due to a sight-line of reduced extinction. What is not so easy to estimate is the number of false negatives, clusters which exist but are not currently being detected by our surveys. In order to derive critical characteristics of the Milky Way's massive cluster population, such as cluster mass function and cluster lifetimes, one must be able to estimate the characteristics of these false negatives. Our group has taken on the daunting task of attempting such an estimate by first creating the stellar cluster imaging simulation program, MASSCLEAN. I will present our preliminary models and methods for deriving the biases of current searches.
True 3D display and BeoWulf connectivity
NASA Astrophysics Data System (ADS)
Jannson, Tomasz P.; Kostrzewski, Andrew A.; Kupiec, Stephen A.; Yu, Kevin H.; Aye, Tin M.; Savant, Gajendra D.
2003-09-01
We propose a novel true 3-D display based on holographic optics, called HAD (Holographic Autostereoscopic Display), or Holographic Inverse Look-around and Autostereoscopic Reality (HILAR), its latest generation. It does not require goggles, unlike the state of the art 3-D system which do not work without goggles, and has a table-like 360° look-around capability. Also, novel 3-D image-rendering software, based on Beowulf PC cluster hardware is discussed.
Cluster-lensing: A Python Package for Galaxy Clusters and Miscentering
NASA Astrophysics Data System (ADS)
Ford, Jes; VanderPlas, Jake
2016-12-01
We describe a new open source package for calculating properties of galaxy clusters, including Navarro, Frenk, and White halo profiles with and without the effects of cluster miscentering. This pure-Python package, cluster-lensing, provides well-documented and easy-to-use classes and functions for calculating cluster scaling relations, including mass-richness and mass-concentration relations from the literature, as well as the surface mass density {{Σ }}(R) and differential surface mass density {{Δ }}{{Σ }}(R) profiles, probed by weak lensing magnification and shear. Galaxy cluster miscentering is especially a concern for stacked weak lensing shear studies of galaxy clusters, where offsets between the assumed and the true underlying matter distribution can lead to a significant bias in the mass estimates if not accounted for. This software has been developed and released in a public GitHub repository, and is licensed under the permissive MIT license. The cluster-lensing package is archived on Zenodo. Full documentation, source code, and installation instructions are available at http://jesford.github.io/cluster-lensing/.
Core Collapse: The Race Between Stellar Evolution and Binary Heating
NASA Astrophysics Data System (ADS)
Converse, Joseph M.; Chandar, R.
2012-01-01
The dynamical formation of binary stars can dramatically affect the evolution of their host star clusters. In relatively small clusters (M < 6000 Msun) the most massive stars rapidly form binaries, heating the cluster and preventing any significant contraction of the core. The situation in much larger globular clusters (M 105 Msun) is quite different, with many showing collapsed cores, implying that binary formation did not affect them as severely as lower mass clusters. More massive clusters, however, should take longer to form their binaries, allowing stellar evolution more time to prevent the heating by causing the larger stars to die off. Here, we simulate the evolution of clusters between those of open and globular clusters in order to find at what size a star cluster is able to experience true core collapse. Our simulations make use of a new GPU-based computing cluster recently purchased at the University of Toledo. We also present some benchmarks of this new computational resource.
Performance of cancer cluster Q-statistics for case-control residential histories
Sloan, Chantel D.; Jacquez, Geoffrey M.; Gallagher, Carolyn M.; Ward, Mary H.; Raaschou-Nielsen, Ole; Nordsborg, Rikke Baastrup; Meliker, Jaymie R.
2012-01-01
Few investigations of health event clustering have evaluated residential mobility, though causative exposures for chronic diseases such as cancer often occur long before diagnosis. Recently developed Q-statistics incorporate human mobility into disease cluster investigations by quantifying space- and time-dependent nearest neighbor relationships. Using residential histories from two cancer case-control studies, we created simulated clusters to examine Q-statistic performance. Results suggest the intersection of cases with significant clustering over their life course, Qi, with cases who are constituents of significant local clusters at given times, Qit, yielded the best performance, which improved with increasing cluster size. Upon comparison, a larger proportion of true positives were detected with Kulldorf’s spatial scan method if the time of clustering was provided. We recommend using Q-statistics to identify when and where clustering may have occurred, followed by the scan method to localize the candidate clusters. Future work should investigate the generalizability of these findings. PMID:23149326
Cellular calcium dynamics in lactation and breast cancer: From physiology to pathology
USDA-ARS?s Scientific Manuscript database
Breast cancer is the second leading cause of cancer mortality in women, estimated at nearly 40,000 deaths and more than 230,000 new cases diagnosed in the U.S. this year alone. One of the defining characteristics of breast cancer is the radiographic presence of microcalcifications. These palpable mi...
Kunitake, Jennie A M R; Choi, Siyoung; Nguyen, Kayla X; Lee, Meredith M; He, Frank; Sudilovsky, Daniel; Morris, Patrick G; Jochelson, Maxine S; Hudis, Clifford A; Muller, David A; Fratzl, Peter; Fischbach, Claudia; Masic, Admir; Estroff, Lara A
2018-04-01
Microcalcifications (MCs) are routinely used to detect breast cancer in mammography. Little is known, however, about their materials properties and associated organic matrix, or their correlation to breast cancer prognosis. We combine histopathology, Raman microscopy, and electron microscopy to image MCs within snap-frozen human breast tissue and generate micron-scale resolution correlative maps of crystalline phase, trace metals, particle morphology, and organic matrix chemical signatures within high grade ductal carcinoma in situ (DCIS) and invasive cancer. We reveal the heterogeneity of mineral-matrix pairings, including punctate apatitic particles (<2 µm) with associated trace elements (e.g., F, Na, and unexpectedly Al) distributed within the necrotic cores of DCIS, and both apatite and spheroidal whitlockite particles in invasive cancer within a matrix containing spectroscopic signatures of collagen, non-collagen proteins, cholesterol, carotenoids, and DNA. Among the three DCIS samples, we identify key similarities in MC morphology and distribution, supporting a dystrophic mineralization pathway. This multimodal methodology lays the groundwork for establishing MC heterogeneity in the context of breast cancer biology, and could dramatically improve current prognostic models. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gaona, Enrique; Alfonso, Beatriz Y. Álvarez; Castellanos, Gustavo Casian; Enríquez, Jesús Gabriel Franco
2008-08-01
The goal of the study was to evaluate the first CR digital mammography system (® Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.
Analysis of framelets for breast cancer diagnosis.
Thivya, K S; Sakthivel, P; Venkata Sai, P M
2016-01-01
Breast cancer is the second threatening tumor among the women. The effective way of reducing breast cancer is its early detection which helps to improve the diagnosing process. Digital mammography plays a significant role in mammogram screening at earlier stage of breast carcinoma. Even though, it is very difficult to find accurate abnormality in prevalent screening by radiologists. But the possibility of precise breast cancer screening is encouraged by predicting the accurate type of abnormality through Computer Aided Diagnosis (CAD) systems. The two most important indicators of breast malignancy are microcalcifications and masses. In this study, framelet transform, a multiresolutional analysis is investigated for the classification of the above mentioned two indicators. The statistical and co-occurrence features are extracted from the framelet decomposed mammograms with different resolution levels and support vector machine is employed for classification with k-fold cross validation. This system achieves 94.82% and 100% accuracy in normal/abnormal classification (stage I) and benign/malignant classification (stage II) of mass classification system and 98.57% and 100% for microcalcification system when using the MIAS database.
González, Rocío; Montoto Santomé, Paula; Iglesias Porto, Eva; Pérez Moreiras, M Isabel; Salem Ali, Mohammed; Mateo Cambón, Luis A; Bal Nieves, Fernando; Arija Val, J Felix
2012-12-01
To describe a case of retroperitoneal metastasis of a gonadal germ cell tumour with the "burned-out" phenomenon in a 35 year old patient with a suspected diagnosis of retroperitoneal tumour of neurogenic origin. With the clinical and radiological suspicion of retroperitoneal tumour of neurogenic origin the tumour was removed, via the retroperitoneal space. Pathology showed classic seminoma with foci of atypical or anaplastic seminoma, confined to the tissue sample. After a genital examination showing no alterations, a scrotal ultrasound was requested. This revealed a badly delimited hypoechogenic mass with microcalcifications in the left testis and a heterogeneous echostructure in the right testis, with hypoechogenic areas and some microcalcification. Bilateral orchiectomy was performed, with a pathological study compatible with residual scar tissue in the left testicle and focal findings of germ cell neoplasia, with no intratubular seminoma in the right testis. The suspicion of an extragonadal germ cell tumour with the "burned-out" phenomenon modifies the therapeutic attitude, which should begin with orchiectomy, followed by systemic chemotherapy and the surgery kept in reserve for those cases where residual malignant tissue persists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez
2008-08-11
The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CRmore » Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.« less
al-Rifaie, Mohammad Majid; Aber, Ahmed; Hemanth, Duraiswamy Jude
2015-12-01
This study proposes an umbrella deployment of swarm intelligence algorithm, such as stochastic diffusion search for medical imaging applications. After summarising the results of some previous works which shows how the algorithm assists in the identification of metastasis in bone scans and microcalcifications on mammographs, for the first time, the use of the algorithm in assessing the CT images of the aorta is demonstrated along with its performance in detecting the nasogastric tube in chest X-ray. The swarm intelligence algorithm presented in this study is adapted to address these particular tasks and its functionality is investigated by running the swarms on sample CT images and X-rays whose status have been determined by senior radiologists. In addition, a hybrid swarm intelligence-learning vector quantisation (LVQ) approach is proposed in the context of magnetic resonance (MR) brain image segmentation. The particle swarm optimisation is used to train the LVQ which eliminates the iteration-dependent nature of LVQ. The proposed methodology is used to detect the tumour regions in the abnormal MR brain images.
Cluster signal-to-noise analysis for evaluation of the information content in an image.
Weerawanich, Warangkana; Shimizu, Mayumi; Takeshita, Yohei; Okamura, Kazutoshi; Yoshida, Shoko; Yoshiura, Kazunori
2018-01-01
(1) To develop an observer-free method of analysing image quality related to the observer performance in the detection task and (2) to analyse observer behaviour patterns in the detection of small mass changes in cone-beam CT images. 13 observers detected holes in a Teflon phantom in cone-beam CT images. Using the same images, we developed a new method, cluster signal-to-noise analysis, to detect the holes by applying various cut-off values using ImageJ and reconstructing cluster signal-to-noise curves. We then evaluated the correlation between cluster signal-to-noise analysis and the observer performance test. We measured the background noise in each image to evaluate the relationship with false positive rates (FPRs) of the observers. Correlations between mean FPRs and intra- and interobserver variations were also evaluated. Moreover, we calculated true positive rates (TPRs) and accuracies from background noise and evaluated their correlations with TPRs from observers. Cluster signal-to-noise curves were derived in cluster signal-to-noise analysis. They yield the detection of signals (true holes) related to noise (false holes). This method correlated highly with the observer performance test (R 2 = 0.9296). In noisy images, increasing background noise resulted in higher FPRs and larger intra- and interobserver variations. TPRs and accuracies calculated from background noise had high correlation with actual TPRs from observers; R 2 was 0.9244 and 0.9338, respectively. Cluster signal-to-noise analysis can simulate the detection performance of observers and thus replace the observer performance test in the evaluation of image quality. Erroneous decision-making increased with increasing background noise.
Exploring undergraduates' understanding of photosynthesis using diagnostic question clusters.
Parker, Joyce M; Anderson, Charles W; Heidemann, Merle; Merrill, John; Merritt, Brett; Richmond, Gail; Urban-Lurain, Mark
2012-01-01
We present a diagnostic question cluster (DQC) that assesses undergraduates' thinking about photosynthesis. This assessment tool is not designed to identify individual misconceptions. Rather, it is focused on students' abilities to apply basic concepts about photosynthesis by reasoning with a coordinated set of practices based on a few scientific principles: conservation of matter, conservation of energy, and the hierarchical nature of biological systems. Data on students' responses to the cluster items and uses of some of the questions in multiple-choice, multiple-true/false, and essay formats are compared. A cross-over study indicates that the multiple-true/false format shows promise as a machine-gradable format that identifies students who have a mixture of accurate and inaccurate ideas. In addition, interviews with students about their choices on three multiple-choice questions reveal the fragility of students' understanding. Collectively, the data show that many undergraduates lack both a basic understanding of the role of photosynthesis in plant metabolism and the ability to reason with scientific principles when learning new content. Implications for instruction are discussed.
Exploring Undergraduates' Understanding of Photosynthesis Using Diagnostic Question Clusters
Parker, Joyce M.; Anderson, Charles W.; Heidemann, Merle; Merrill, John; Merritt, Brett; Richmond, Gail; Urban-Lurain, Mark
2012-01-01
We present a diagnostic question cluster (DQC) that assesses undergraduates' thinking about photosynthesis. This assessment tool is not designed to identify individual misconceptions. Rather, it is focused on students' abilities to apply basic concepts about photosynthesis by reasoning with a coordinated set of practices based on a few scientific principles: conservation of matter, conservation of energy, and the hierarchical nature of biological systems. Data on students' responses to the cluster items and uses of some of the questions in multiple-choice, multiple-true/false, and essay formats are compared. A cross-over study indicates that the multiple-true/false format shows promise as a machine-gradable format that identifies students who have a mixture of accurate and inaccurate ideas. In addition, interviews with students about their choices on three multiple-choice questions reveal the fragility of students' understanding. Collectively, the data show that many undergraduates lack both a basic understanding of the role of photosynthesis in plant metabolism and the ability to reason with scientific principles when learning new content. Implications for instruction are discussed. PMID:22383617
Dialani, Vandana; Venkataraman, Shambhavi; Frieling, Gretchen; Schnitt, Stuart J; Mehta, Tejas S
2014-01-01
To determine whether flat epithelial atypia (FEA) found in isolation on large core vacuum-assisted biopsy (CNB) requires surgical excision. After Institutional Review Board approval, pathology reports of all patients who underwent CNB from January 1, 2005 to December 31, 2010 were reviewed. All patients with reports of isolated FEA without other atypia or in situ or invasive carcinoma were identified. Patient age, history, target on imaging, biopsy modality, and residual target post CNB noted. Histology of CNB's (blinded to surgical outcome) and subsequent surgical excisions were reviewed by a dedicated breast pathologist. Only cases with confirmed isolated FEA on review were used for data analysis. Of 2,556 CNB's performed over 6 years, 37 (1.4%) had isolated FEA confirmed on review, comprising our study population. Thirty (81%) had biopsy for calcifications on mammography and 7 (19%) for mass or non-mass like enhancement on magnetic resonance imaging. There were no US guided CNBs that met our inclusion criteria. 29 (78.4%) underwent surgical excision, 6 (16.2%) had imaging follow-up, and 2 (5.4%) were lost to follow-up. Of the 29 with surgery, 2 (6.9%) had "upgrade" to low-grade in situ carcinoma (1 ductal and 1 pleomorphic lobular), 5 (17.2%) had "change in diagnosis" to other atypia (ADH/ALH), 15 (51.7%) had additional FEA and 7 (24.2%) had benign tissue without atypia. Both "upgraded" cases had residual microcalcifications on imaging following CNB. There were no upgrades to invasive cancers. In our study, none of 29 with isolated FEA on CNB had invasive cancer on surgical excision. If there are residual microcalcifications or residual lesion after a CNB that shows isolated FEA, excision is warranted, due to the possibility of other atypia (ADH/ALH [17.2%] or DCIS [5.4%]). If there are no residual microcalcifications following CNB, imaging follow-up as an alternative to surgery may be a reasonable option. © 2014 Wiley Periodicals, Inc.
Wang, X Q; Wei, W; Wei, X; Xu, Y; Wang, H L; Xing, X J; Zhang, S
2018-03-23
Objective: To investigate the correlation between ultrasonographic features of papillary thyroid carcinoma and central cervical lymph node metastasis. Methods: We retrospectively analyzed 486 patients with papillary thyroid carcinoma(PTC), pathologically confirmed after surgery in Tianjin Medical University Cancer Institute & Hospital. All patients were divided into central cervical lymph node metastasis group and non-metastasis group. No lateral cervical lymph node metastasis was found in preoperative ultrasonography and postoperative pathology. The characteristics of the ultrasound was observed and analyzed. Results: 297 out of 486 patients with papillary thyroid carcinomahad central metastasis, and the other 189 cases did not. Take pathology results as a standard, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of preoperative ultrasound diagnosis in PTC patients with central cervical lymph node metastasis were 35.3%, 88.6%, 83.2%, 47.4%, 56.6%, respectively. Univariate analysis showed that multi-focus, taller-than-wide, diameter>1 cm, located in the lower pole, ill-defined margin, hypoechogenicity, micro-calcification, capsule invasion more than 1/4 perimeter of papillary thyroid carcinoma were significantly associated with central cervical lymph node metastasis (all P <0.05). Multivariate analysis showed that diameter>1 cm, micro-calcification, capsule invasion more than 1/4 perimeter of papillary thyroid carcinoma became independent risk factors of central cervical neck lymph node metastasis (all P <0.05). Conclusions: Preoperative description of ultrasonographical features has important value to assess central cervical lymph node metastasis in patients with papillary thyroid carcinoma. More information could be provided for clinical treatment. When the papillary thyroid carcinoma presented as diameter>1 cm, micro-calcification, and capsule invasion more than 1/4 perimeter of, there will be a greater risk of central cervical lymph node metastasis, and we shall suggest prophylactic central lymph cervical node dissection.
Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz
2016-01-01
Background Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. Material/Methods The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. Results Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). Conclusions Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions. PMID:27768681
Łuczyńska, Elżbieta; Niemiec, Joanna; Hendrick, Edward; Heinze, Sylwia; Jaszczyński, Janusz; Jakubowicz, Jerzy; Sas-Korczyńska, Beata; Rys, Janusz
2016-10-21
BACKGROUND Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. MATERIAL AND METHODS The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. RESULTS Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). CONCLUSIONS Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions.
[Radiological control intraoperatory of a surgical piece in non palpable breast lesions].
Ruvalcaba Limón, Eva; Espejo Fonseca, Ruby; Bautista Piña, Verónica; Madero Preciado, Luis; Capurso Garcia, Marino; Serratos Garduño, José Eduardo; Hohenstein, Fernando Guisa; Rodríguez Cuevas, Sergio
2009-09-01
nonconcrete the mammary injuries are frequent in programs of detection of breast cancer, estereotaxic or ecographic marking is required to realize its split. The intrasurgical radiation control of the surgical piece is indispensable to evaluate the margins of the mammary cancer. to determine the effectiveness of the intrasurgical radiation control of the surgical piece in nonconcrete mammary injuries to diminish the surgical reinterventions to extend margins. women with nonconcrete mammary injuries to those who biopsy by split became, previous marking and intraoperating radiation control of the surgical piece to value margins (suitable margin the same or major of 10 mm, smaller inadequate margin of 10 mm). Intrasurgical reesicion in inadequate radiological margins became. The demographic characteristics, masto-ecographics images, histopathology of the injuries and the radiological-histopatol6gica correlation of the margins studied. Cross-sectional, prospective and descriptive study. 103 patients with 113 nonconcrete mammary injuries included themselves, with age average of 51,35 (32-73) years. In all the injuries the intrasurgical radiation control became of the surgical piece. The prevalence of mammary cancer was of 28.3% (32/113), that corresponds to stellar images (42.8%), suspicious microcalcifications with density (39.2%), microcalcifications (31.2%) and nodules (20%). Of the 32 cancers, 16 had inadequate radiological margins that required intraoperating reescision; suitable histopatologic margins in 100% were obtained (16/16). The 16 (62.5%) cancers without intraoperating reescisi6n by suitable radiological margins had suitable histopatologic margins and 37.5% (6/16) inadequate ones that required surgical reinterventionn to control the margins. The discrepancy between margins was related to microcalcifications in 83.3% of the injuries. the intrasurgical radiation control of the surgical piece is effective to evaluate margins; the intrasurgical reescisión changed inadequate margins to suitable in 50% (16/32) of the cancers; only 18.7% (6/32) of the total of cases required another surgery to control the margins.
Digital mammography: comparative performance of color LCD and monochrome CRT displays.
Samei, Ehsan; Poolla, Ananth; Ulissey, Michael J; Lewin, John M
2007-05-01
To evaluate the comparative performance of high-fidelity liquid crystal display (LCD) and cathode ray tube (CRT) devices for mammography applications, and to assess the impact of LCD viewing angle on detection accuracy. Ninety 1 k x 1 k images were selected from a database of digital mammograms: 30 without any abnormality present, 30 with subtle masses, and 30 with subtle microcalcifications. The images were used with waived informed consent, Health Insurance Portability and Accountability Act compliance, and Institutional Review Board approval. With postprocessing presentation identical to those of the commercial mammography system used, 1 k x 1 k sections of images were viewed on a monochrome CRT and a color LCD in native grayscale, and with a grayscale representative of images viewed from a 30 degrees or 50 degrees off-normal viewing angle. Randomized images were independently scored by four experienced breast radiologists for the presence of lesions using a 0-100 grading scale. To compare diagnostic performance of the display modes, observer scores were analyzed using receiver operating characteristic (ROC) and analysis of variance. For masses and microcalcifications, the detection rate in terms of the area under the ROC curve (A(z)) showed a 2% increase and a 4% decrease from CRT to LCD, respectively. However, differences were not statistically significant (P > .05). The viewing angle data showed better microcalcification detection but lower mass detection at 30 degrees viewing orientation. The overall results varied notably from observer to observer yielding no statistically discernible trends across all observers, suggesting that within the 0-50 degrees viewing angle range and in a controlled observer experiment, the variation in the contrast response of the LCD has little or no impact on the detection of mammographic lesions. Although CRTs and LCDs differ in terms of angular response, resolution, noise, and color, these characteristics seem to have little influence on the detection of mammographic lesions. The results suggest comparable performance in clinical applications of the two devices.
Uncertainties in the cluster-cluster correlation function
NASA Astrophysics Data System (ADS)
Ling, E. N.; Frenk, C. S.; Barrow, J. D.
1986-12-01
The bootstrap resampling technique is applied to estimate sampling errors and significance levels of the two-point correlation functions determined for a subset of the CfA redshift survey of galaxies and a redshift sample of 104 Abell clusters. The angular correlation function for a sample of 1664 Abell clusters is also calculated. The standard errors in xi(r) for the Abell data are found to be considerably larger than quoted 'Poisson errors'. The best estimate for the ratio of the correlation length of Abell clusters (richness class R greater than or equal to 1, distance class D less than or equal to 4) to that of CfA galaxies is 4.2 + 1.4 or - 1.0 (68 percentile error). The enhancement of cluster clustering over galaxy clustering is statistically significant in the presence of resampling errors. The uncertainties found do not include the effects of possible systematic biases in the galaxy and cluster catalogs and could be regarded as lower bounds on the true uncertainty range.
Reconstructing galaxy histories from globular clusters.
West, Michael J; Côté, Patrick; Marzke, Ronald O; Jordán, Andrés
2004-01-01
Nearly a century after the true nature of galaxies as distant 'island universes' was established, their origin and evolution remain great unsolved problems of modern astrophysics. One of the most promising ways to investigate galaxy formation is to study the ubiquitous globular star clusters that surround most galaxies. Globular clusters are compact groups of up to a few million stars. They generally formed early in the history of the Universe, but have survived the interactions and mergers that alter substantially their parent galaxies. Recent advances in our understanding of the globular cluster systems of the Milky Way and other galaxies point to a complex picture of galaxy genesis driven by cannibalism, collisions, bursts of star formation and other tumultuous events.
Carlsten, Chris; Oron, Assaf P.; Curtiss, Heidi; Jarvis, Sara; Daniell, William; Kaufman, Joel D.
2013-01-01
Background Diesel exhaust (DE) exposures are very common, yet exposure-related symptoms haven’t been rigorously examined. Objective Describe symptomatic responses to freshly generated and diluted DE and filtered air (FA) in a controlled human exposure setting; assess whether such responses are altered by perception of exposure. Methods 43 subjects participated within three double-blind crossover experiments to order-randomized DE exposure levels (FA and DE calibrated at 100 and/or 200 micrograms/m3 particulate matter of diameter less than 2.5 microns), and completed questionnaires regarding symptoms and dose perception. Results For a given symptom cluster, the majority of those exposed to moderate concentrations of diesel exhaust do not report such symptoms. The most commonly reported symptom cluster was of the nose (29%). Blinding to exposure is generally effective. Perceived exposure, rather than true exposure, is the dominant modifier of symptom reporting. Conclusion Controlled human exposure to moderate-dose diesel exhaust is associated with a range of mild symptoms, though the majority of individuals will not experience any given symptom. Blinding to DE exposure is generally effective. Perceived DE exposure, rather than true DE exposure, is the dominant modifier of symptom reporting. PMID:24358296
Xiao, Yongling; Abrahamowicz, Michal
2010-03-30
We propose two bootstrap-based methods to correct the standard errors (SEs) from Cox's model for within-cluster correlation of right-censored event times. The cluster-bootstrap method resamples, with replacement, only the clusters, whereas the two-step bootstrap method resamples (i) the clusters, and (ii) individuals within each selected cluster, with replacement. In simulations, we evaluate both methods and compare them with the existing robust variance estimator and the shared gamma frailty model, which are available in statistical software packages. We simulate clustered event time data, with latent cluster-level random effects, which are ignored in the conventional Cox's model. For cluster-level covariates, both proposed bootstrap methods yield accurate SEs, and type I error rates, and acceptable coverage rates, regardless of the true random effects distribution, and avoid serious variance under-estimation by conventional Cox-based standard errors. However, the two-step bootstrap method over-estimates the variance for individual-level covariates. We also apply the proposed bootstrap methods to obtain confidence bands around flexible estimates of time-dependent effects in a real-life analysis of cluster event times.
Statistical Significance for Hierarchical Clustering
Kimes, Patrick K.; Liu, Yufeng; Hayes, D. Neil; Marron, J. S.
2017-01-01
Summary Cluster analysis has proved to be an invaluable tool for the exploratory and unsupervised analysis of high dimensional datasets. Among methods for clustering, hierarchical approaches have enjoyed substantial popularity in genomics and other fields for their ability to simultaneously uncover multiple layers of clustering structure. A critical and challenging question in cluster analysis is whether the identified clusters represent important underlying structure or are artifacts of natural sampling variation. Few approaches have been proposed for addressing this problem in the context of hierarchical clustering, for which the problem is further complicated by the natural tree structure of the partition, and the multiplicity of tests required to parse the layers of nested clusters. In this paper, we propose a Monte Carlo based approach for testing statistical significance in hierarchical clustering which addresses these issues. The approach is implemented as a sequential testing procedure guaranteeing control of the family-wise error rate. Theoretical justification is provided for our approach, and its power to detect true clustering structure is illustrated through several simulation studies and applications to two cancer gene expression datasets. PMID:28099990
NASA Technical Reports Server (NTRS)
Garofalini, S. H.; Halicioglu, T.; Pound, G. M.
1981-01-01
Molecular dynamics was used to study the structure, dispersion and short-time behavior of ten-atom clusters adsorbed onto amorphous and crystalline substrates, in which the cluster atoms differed from the substrate atoms. Two adatom-substrate model systems were chosen; one, in which the interaction energy between adatom pairs was greater than that between substrate pairs, and the other, in which the reverse was true. At relatively low temperature ranges, increased dispersion of cluster atoms occurred: (a) on the amorphous substrate as compared to the FCC(100) surface, (b) with increasing reduced temperature, and (c) with adatom-substrate interaction energy stronger than adatom-adatom interaction. Two-dimensional clusters (rafts) on the FCC(100) surface displayed migration of edge atoms only, indicating a mechanism for the cluster rotation and shape changes found in experimental studies.
NASA Astrophysics Data System (ADS)
Gandomkar, Ziba; Tay, Kevin; Ryder, Will; Brennan, Patrick C.; Mello-Thoms, Claudia
2016-03-01
Radiologists' gaze-related parameters combined with image-based features were utilized to classify suspicious mammographic areas ultimately scored as True Positives (TP) and False Positives (FP). Eight breast radiologists read 120 two-view digital mammograms of which 59 had biopsy proven cancer. Eye tracking data was collected and nearby fixations were clustered together. Suspicious areas on mammograms were independently identified based on thresholding an intensity saliency map followed by automatic segmentation and pruning steps. For each radiologist reported area, radiologist's fixation clusters in the area, as well as neighboring suspicious areas within 2.5° of the center of fixation, were found. A 45-dimensional feature vector containing gaze parameters of the corresponding cluster along with image-based characteristics was constructed. Gaze parameters included total number of fixations in the cluster, dwell time, time to hit the cluster for the first time, maximum number of consecutive fixations, and saccade magnitude of the first fixation in the cluster. Image-based features consisted of intensity, shape, and texture descriptors extracted from the region around the suspicious area, its surrounding tissue, and the entire breast. For each radiologist, a userspecific Support Vector Machine (SVM) model was built to classify the reported areas as TPs or FPs. Leave-one-out cross validation was utilized to avoid over-fitting. A feature selection step was embedded in the SVM training procedure by allowing radial basis function kernels to have 45 scaling factors. The proposed method was compared with the radiologists' performance using the jackknife alternative free-response receiver operating characteristic (JAFROC). The JAFROC figure of merit increased significantly for six radiologists.
Seamless lesion insertion in digital mammography: methodology and reader study
NASA Astrophysics Data System (ADS)
Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman
2016-03-01
Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.
Acquiring skill at medical image inspection: learning localized in early visual processes
NASA Astrophysics Data System (ADS)
Sowden, Paul T.; Davies, Ian R. L.; Roling, Penny; Watt, Simon J.
1997-04-01
Acquisition of the skill of medical image inspection could be due to changes in visual search processes, 'low-level' sensory learning, and higher level 'conceptual learning.' Here, we report two studies that investigate the extent to which learning in medical image inspection involves low- level learning. Early in the visual processing pathway cells are selective for direction of luminance contrast. We exploit this in the present studies by using transfer across direction of contrast as a 'marker' to indicate the level of processing at which learning occurs. In both studies twelve observers trained for four days at detecting features in x- ray images (experiment one equals discs in the Nijmegen phantom, experiment two equals micro-calcification clusters in digitized mammograms). Half the observers examined negative luminance contrast versions of the images and the remainder examined positive contrast versions. On the fifth day, observers swapped to inspect their respective opposite contrast images. In both experiments leaning occurred across sessions. In experiment one, learning did not transfer across direction of luminance contrast, while in experiment two there was only partial transfer. These findings are consistent with the contention that some of the leaning was localized early in the visual processing pathway. The implications of these results for current medical image inspection training schedules are discussed.
Uchoi, Ajit; Malik, Surendra Kumar; Choudhary, Ravish; Kumar, Susheel; Rohini, M R; Pal, Digvender; Ercisli, Sezai; Chaudhury, Rekha
2016-06-01
Phylogenetic relationships of Indian Citron (Citrus medica L.) with other important Citrus species have been inferred through sequence analyses of rbcL and matK gene region of chloroplast DNA. The study was based on 23 accessions of Citrus genotypes representing 15 taxa of Indian Citrus, collected from wild, semi-wild, and domesticated stocks. The phylogeny was inferred using the maximum parsimony (MP) and neighbor-joining (NJ) methods. Both MP and NJ trees separated all the 23 accessions of Citrus into five distinct clusters. The chloroplast DNA (cpDNA) analysis based on rbcL and matK sequence data carried out in Indian taxa of Citrus was useful in differentiating all the true species and species/varieties of probable hybrid origin in distinct clusters or groups. Sequence analysis based on rbcL and matK gene provided unambiguous identification and disposition of true species like C. maxima, C. medica, C. reticulata, and related hybrids/cultivars. The separation of C. maxima, C. medica, and C. reticulata in distinct clusters or sub-clusters supports their distinctiveness as the basic species of edible Citrus. However, the cpDNA sequence analysis of rbcL and matK gene could not find any clear cut differentiation between subgenera Citrus and Papeda as proposed in Swingle's system of classification.
A spatial scan statistic for multiple clusters.
Li, Xiao-Zhou; Wang, Jin-Feng; Yang, Wei-Zhong; Li, Zhong-Jie; Lai, Sheng-Jie
2011-10-01
Spatial scan statistics are commonly used for geographical disease surveillance and cluster detection. While there are multiple clusters coexisting in the study area, they become difficult to detect because of clusters' shadowing effect to each other. The recently proposed sequential method showed its better power for detecting the second weaker cluster, but did not improve the ability of detecting the first stronger cluster which is more important than the second one. We propose a new extension of the spatial scan statistic which could be used to detect multiple clusters. Through constructing two or more clusters in the alternative hypothesis, our proposed method accounts for other coexisting clusters in the detecting and evaluating process. The performance of the proposed method is compared to the sequential method through an intensive simulation study, in which our proposed method shows better power in terms of both rejecting the null hypothesis and accurately detecting the coexisting clusters. In the real study of hand-foot-mouth disease data in Pingdu city, a true cluster town is successfully detected by our proposed method, which cannot be evaluated to be statistically significant by the standard method due to another cluster's shadowing effect. Copyright © 2011 Elsevier Inc. All rights reserved.
Improved Ultrasonic Imaging of the Breast
2005-08-01
differentiation of benign and malignant lesions. This method yields high resolution images with minimal statistical variability. We have formed images in... and malignant masses often exhibit only subtle image differences. We have invented a new technique that uses modified ultrasound equipment to form...between malignant and benign lesions. The utility of ultrasound is limited because microcalcifications (MCs) are not typically visible and because benign
Improved Ultrasonic Imaging of the Breast
2002-08-01
differentiation of benign and malignant lesions. This method yields high resolution images with minimal statistical variability. In this first year of... and malignant masses often exhibit only subtle image differences. We have invented a new technique that uses modified ultrasound equipment to form...between malignant and benign lesions. The utility of ultrasound is limited because microcalcifications (MCs) are not typically visible and because benign
Improved Ultrasonic Imaging of the Breast
2004-08-01
differentiation of benign and malignant lesions. This method yields high resolution images with minimal statistical variability. We have formed images in... and malignant masses often exhibit only subtle image differences. We have invented a new technique that uses modified ultrasound equipment to form...between malignant and benign lesions. The utility of ultrasound is limited because microcalcifications (MCs) are not typically visible and because benign
MacGrogan, Gaëtan; Mathoulin-Pélissier, Simone; Vincent-Salomon, Anne; Soubeyran, Isabelle; Picot, Véronique; Coindre, Jean-Michel; Mauriac, Louis
2007-01-01
This study analyzes the occurrence of epithelial atypia in 2,833 serially sectioned surgical breast biopsies (SB) performed for microcalcifications (median number of blocks per SB:26) and the occurrence of subsequent cancer after an initial diagnosis of epithelial atypia (median follow-up 160 months). Epithelial atypia (flat epithelial atypia, atypical ductal hyperplasia, and lobular neoplasia) were found in 971 SB, with and without a concomitant cancer in 301 (31%) and 670 (69%) SB, respectively. Thus, isolated epithelial atypia were found in 670 out of the 2,833 SB (23%). Concomitant cancers corresponded to ductal carcinomas in situ and micro-invasive (77%), invasive ductal carcinomas not otherwise specified (15%), invasive lobular carcinomas (4%), and tubular carcinomas (4%). Fifteen out of the 443 patients with isolated epithelial atypia developed a subsequent ipsilateral (n = 14) and contralateral (n = 1) invasive cancer. The high slide rating might explain the high percentages of epithelial atypia and concomitant cancers and the low percentage of subsequent cancer after a diagnosis of epithelial atypia as a single lesion. Epithelial atypia could be more a risk marker of concomitant than subsequent cancer. PMID:17551752
de Mascarel, Isabelle; MacGrogan, Gaëtan; Mathoulin-Pélissier, Simone; Vincent-Salomon, Anne; Soubeyran, Isabelle; Picot, Véronique; Coindre, Jean-Michel; Mauriac, Louis
2007-07-01
This study analyzes the occurrence of epithelial atypia in 2,833 serially sectioned surgical breast biopsies (SB) performed for microcalcifications (median number of blocks per SB:26) and the occurrence of subsequent cancer after an initial diagnosis of epithelial atypia (median follow-up 160 months). Epithelial atypia (flat epithelial atypia, atypical ductal hyperplasia, and lobular neoplasia) were found in 971 SB, with and without a concomitant cancer in 301 (31%) and 670 (69%) SB, respectively. Thus, isolated epithelial atypia were found in 670 out of the 2,833 SB (23%). Concomitant cancers corresponded to ductal carcinomas in situ and micro-invasive (77%), invasive ductal carcinomas not otherwise specified (15%), invasive lobular carcinomas (4%), and tubular carcinomas (4%). Fifteen out of the 443 patients with isolated epithelial atypia developed a subsequent ipsilateral (n = 14) and contralateral (n = 1) invasive cancer. The high slide rating might explain the high percentages of epithelial atypia and concomitant cancers and the low percentage of subsequent cancer after a diagnosis of epithelial atypia as a single lesion. Epithelial atypia could be more a risk marker of concomitant than subsequent cancer.
Analyser-based mammography using single-image reconstruction.
Briedis, Dahliyani; Siu, Karen K W; Paganin, David M; Pavlov, Konstantin M; Lewis, Rob A
2005-08-07
We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.
Cyclic nocturnal awakening: a warning sign of a cluster bout.
Martins, Isabel Pavão
2015-04-01
Cluster headache is an excruciating unilateral headache with autonomic symptoms whose periodic nocturnal activity, which interrupts sleep, has been attributed to a hypothalamic generator. We describe a patient with a longstanding episodic cluster headache who experienced, on two occasions, a period of nocturnal awakenings without pain or autonomic symptoms, lasting one week before the onset of a cluster bout. Awakenings occurred twice/night at the same hours of impending cluster attacks and had no apparent trigger, being unusual for this patient who had no previous sleep disturbances. Neurological examination and brain imaging were normal. This case documents two new aspects of cluster headache. It suggests that repeated nocturnal awakenings can be a warning sign of an impending cluster period, a finding that may have therapeutic implications, and also that hypothalamic activation may begin several days before trigemino-autonomic symptoms, thus behaving as a true bout generator. © International Headache Society 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
VarBin, a novel method for classifying true and false positive variants in NGS data
2013-01-01
Background Variant discovery for rare genetic diseases using Illumina genome or exome sequencing involves screening of up to millions of variants to find only the one or few causative variant(s). Sequencing or alignment errors create "false positive" variants, which are often retained in the variant screening process. Methods to remove false positive variants often retain many false positive variants. This report presents VarBin, a method to prioritize variants based on a false positive variant likelihood prediction. Methods VarBin uses the Genome Analysis Toolkit variant calling software to calculate the variant-to-wild type genotype likelihood ratio at each variant change and position divided by read depth. The resulting Phred-scaled, likelihood-ratio by depth (PLRD) was used to segregate variants into 4 Bins with Bin 1 variants most likely true and Bin 4 most likely false positive. PLRD values were calculated for a proband of interest and 41 additional Illumina HiSeq, exome and whole genome samples (proband's family or unrelated samples). At variant sites without apparent sequencing or alignment error, wild type/non-variant calls cluster near -3 PLRD and variant calls typically cluster above 10 PLRD. Sites with systematic variant calling problems (evident by variant quality scores and biases as well as displayed on the iGV viewer) tend to have higher and more variable wild type/non-variant PLRD values. Depending on the separation of a proband's variant PLRD value from the cluster of wild type/non-variant PLRD values for background samples at the same variant change and position, the VarBin method's classification is assigned to each proband variant (Bin 1 to Bin 4). Results To assess VarBin performance, Sanger sequencing was performed on 98 variants in the proband and background samples. True variants were confirmed in 97% of Bin 1 variants, 30% of Bin 2, and 0% of Bin 3/Bin 4. Conclusions These data indicate that VarBin correctly classifies the majority of true variants as Bin 1 and Bin 3/4 contained only false positive variants. The "uncertain" Bin 2 contained both true and false positive variants. Future work will further differentiate the variants in Bin 2. PMID:24266885
Nixon, Richard M; Duffy, Stephen W; Fender, Guy R K
2003-09-24
The Anglia Menorrhagia Education Study (AMES) is a randomized controlled trial testing the effectiveness of an education package applied to general practices. Binary data are available from two sources; general practitioner reported referrals to hospital, and referrals to hospital determined by independent audit of the general practices. The former may be regarded as a surrogate for the latter, which is regarded as the true endpoint. Data are only available for the true end point on a sub set of the practices, but there are surrogate data for almost all of the audited practices and for most of the remaining practices. The aim of this paper was to estimate the treatment effect using data from every practice in the study. Where the true endpoint was not available, it was estimated by three approaches, a regression method, multiple imputation and a full likelihood model. Including the surrogate data in the analysis yielded an estimate of the treatment effect which was more precise than an estimate gained from using the true end point data alone. The full likelihood method provides a new imputation tool at the disposal of trials with surrogate data.
The Clinical Relevance of Psammoma Body and Hashimoto Thyroiditis in Papillary Thyroid Carcinoma
Cai, Ye-Feng; Wang, Qing-Xuan; Ni, Chun-Jue; Guo, Gui-Long; Li, Quan; Wang, Ou-Chen; Wu, Liang; Du, Hai-Yan; You, Jie; Zhang, Xiao-Hua
2015-01-01
Abstract This study aims to investigate the impact of psammoma body (PB) on papillary thyroid carcinoma (PTC), and evaluate the association among PB, Hashimoto thyroiditis (HT), and other clinicopathologic characteristics in PTC patients. We conducted a retrospective case-control study involving 1052 PTC patients who underwent total thyroidectomy or lobectomy with lymph node dissection. Psammoma body was observed in 324 out of 1052 PTC (30.8%) patients. Ultrasonographic (US) calcification (P < 0.001), multifocality of the tumor (P = 0.047), lymph node metastasis (LNM) (P < 0.001), HT (P < 0.001), and Primary tumor (T), Regional lymph nodes (N), Distant metastasis (M) staging (P = 0.001) were significantly related to the presence of PB. The presence of PB was significantly associated with US microcalcification (P < 0.001). In the subgroup with HT, compared with the patients without PB, the patients with PB exhibited a higher frequency of central LNM (54.7% vs 32.1%; P < 0.001) and US microcalcification (94.7% vs 38.8%; P < 0.001), as well as smaller tumors (0.9 ± 0.6 vs 1.3 ± 0.9 cm; P < 0.001). In the subgroup without HT, the patients with PB displayed a higher incidence of lateral LNM (25.8% vs 14.6%; P < 0.001), US microcalcification (87.3% vs 52.5%; P < 0.001), and extrathyroidal extension (47.2% vs 34.8%; P = 0.001), as well as larger tumors (1.3 ± 0.9 vs 1.0 ± 0.8 cm; P < 0.001) than without PB. Moreover, in the subgroup with PB, the PTC patients with HT showed a higher LNM (77.9% vs 57.2%; P < 0.001) and a lower frequency of extrathyroidal extension (20.0% vs 47.2%; P < 0.001) than without HT. Psammoma body is a useful predictor of aggressive tumor behavior in PTC patients. HT with PB shows more aggressive behaviors than non-HT with PB in PTC patients. PMID:26554782
Cai, Ye-Feng; Wang, Qing-Xuan; Ni, Chun-Jue; Guo, Gui-Long; Li, Quan; Wang, Ou-Chen; Wu, Liang; Du, Hai-Yan; You, Jie; Zhang, Xiao-Hua
2015-11-01
This study aims to investigate the impact of psammoma body (PB) on papillary thyroid carcinoma (PTC), and evaluate the association among PB, Hashimoto thyroiditis (HT), and other clinicopathologic characteristics in PTC patients.We conducted a retrospective case-control study involving 1052 PTC patients who underwent total thyroidectomy or lobectomy with lymph node dissection.Psammoma body was observed in 324 out of 1052 PTC (30.8%) patients. Ultrasonographic (US) calcification (P < 0.001), multifocality of the tumor (P = 0.047), lymph node metastasis (LNM) (P < 0.001), HT (P < 0.001), and Primary tumor (T), Regional lymph nodes (N), Distant metastasis (M) staging (P = 0.001) were significantly related to the presence of PB. The presence of PB was significantly associated with US microcalcification (P < 0.001). In the subgroup with HT, compared with the patients without PB, the patients with PB exhibited a higher frequency of central LNM (54.7% vs 32.1%; P < 0.001) and US microcalcification (94.7% vs 38.8%; P < 0.001), as well as smaller tumors (0.9 ± 0.6 vs 1.3 ± 0.9 cm; P < 0.001). In the subgroup without HT, the patients with PB displayed a higher incidence of lateral LNM (25.8% vs 14.6%; P < 0.001), US microcalcification (87.3% vs 52.5%; P < 0.001), and extrathyroidal extension (47.2% vs 34.8%; P = 0.001), as well as larger tumors (1.3 ± 0.9 vs 1.0 ± 0.8 cm; P < 0.001) than without PB. Moreover, in the subgroup with PB, the PTC patients with HT showed a higher LNM (77.9% vs 57.2%; P < 0.001) and a lower frequency of extrathyroidal extension (20.0% vs 47.2%; P < 0.001) than without HT.Psammoma body is a useful predictor of aggressive tumor behavior in PTC patients. HT with PB shows more aggressive behaviors than non-HT with PB in PTC patients.
Automated detection scheme of architectural distortion in mammograms using adaptive Gabor filter
NASA Astrophysics Data System (ADS)
Yoshikawa, Ruriha; Teramoto, Atsushi; Matsubara, Tomoko; Fujita, Hiroshi
2013-03-01
Breast cancer is a serious health concern for all women. Computer-aided detection for mammography has been used for detecting mass and micro-calcification. However, there are challenges regarding the automated detection of the architectural distortion about the sensitivity. In this study, we propose a novel automated method for detecting architectural distortion. Our method consists of the analysis of the mammary gland structure, detection of the distorted region, and reduction of false positive results. We developed the adaptive Gabor filter for analyzing the mammary gland structure that decides filter parameters depending on the thickness of the gland structure. As for post-processing, healthy mammary glands that run from the nipple to the chest wall are eliminated by angle analysis. Moreover, background mammary glands are removed based on the intensity output image obtained from adaptive Gabor filter. The distorted region of the mammary gland is then detected as an initial candidate using a concentration index followed by binarization and labeling. False positives in the initial candidate are eliminated using 23 types of characteristic features and a support vector machine. In the experiments, we compared the automated detection results with interpretations by a radiologist using 50 cases (200 images) from the Digital Database of Screening Mammography (DDSM). As a result, true positive rate was 82.72%, and the number of false positive per image was 1.39. There results indicate that the proposed method may be useful for detecting architectural distortion in mammograms.
Two Fe-S clusters catalyse sulfur insertion by Radical-SAM methylthiotransferases
Forouhar, Farhad; Arragain, Simon; Atta, Mohamed; Gambarelli, Serge; Mouesca, Jean-Marie; Hussain, Munif; Xiao, Rong; Kieffer-Jaquinod, Sylvie; Seetharaman, Jayaraman; Acton, Thomas B.; Montelione, Gaetano T.
2014-01-01
How living organisms create carbon-sulfur bonds during biosynthesis of critical sulphur-containing compounds is still poorly understood. The methylthiotransferases MiaB and RimO catalyze sulfur insertion into tRNAs and ribosomal protein S12, respectively. Both belong to a sub-group of Radical-SAM enzymes that bear two [4Fe-4S] clusters. One cluster binds S-Adenosylmethionine and generates an Ado• radical via a well- established mechanism. However, the precise role of the second cluster is unclear. For some sulfur-inserting Radical-SAM enzymes, this cluster has been proposed to act as a sacrificial source of sulfur for the reaction. In this paper, we report parallel enzymological, spectroscopic and crystallographic investigations of RimO and MiaB, which provide the first evidence that these enzymes are true catalysts and support a new sulfation mechanism involving activation of an exogenous sulfur co-substrate at an exchangeable coordination site on the second cluster, which remains intact during the reaction. PMID:23542644
Clusterization in Ternary Fission
NASA Astrophysics Data System (ADS)
Kamanin, D. V.; Pyatkov, Y. V.
This lecture notes are devoted to the new kind of ternary decay of low excited heavy nuclei called by us "collinear cluster tri-partition" (CCT) due to the features of the effect observed, namely, decay partners fly away almost collinearly and at least one of them has magic nucleon composition. At the early stage of our work the process of "true ternary fission" (fission of the nucleus into three fragments of comparable masses) was considered to be undiscovered for low excited heavy nuclei. Another possible prototype—three body cluster radioactivity—was also unknown. The most close to the CCT phenomenon, at least cinematically, stands so called "polar emission", but only very light ions (up to isotopes of Be) were observed so far.
Jungle Computing: Distributed Supercomputing Beyond Clusters, Grids, and Clouds
NASA Astrophysics Data System (ADS)
Seinstra, Frank J.; Maassen, Jason; van Nieuwpoort, Rob V.; Drost, Niels; van Kessel, Timo; van Werkhoven, Ben; Urbani, Jacopo; Jacobs, Ceriel; Kielmann, Thilo; Bal, Henri E.
In recent years, the application of high-performance and distributed computing in scientific practice has become increasingly wide spread. Among the most widely available platforms to scientists are clusters, grids, and cloud systems. Such infrastructures currently are undergoing revolutionary change due to the integration of many-core technologies, providing orders-of-magnitude speed improvements for selected compute kernels. With high-performance and distributed computing systems thus becoming more heterogeneous and hierarchical, programming complexity is vastly increased. Further complexities arise because urgent desire for scalability and issues including data distribution, software heterogeneity, and ad hoc hardware availability commonly force scientists into simultaneous use of multiple platforms (e.g., clusters, grids, and clouds used concurrently). A true computing jungle.
Evolutionary biology: microsporidia sex--a missing link to fungi.
Dyer, Paul S
2008-11-11
The evolutionary origins of the microsporidia, a group of intracellular eukaryotic pathogens, have been unclear. Genome analysis of a sex locus and other gene clusters has now revealed conserved synteny with zygomycete fungi, indicating that microsporidia are true fungi descended from a zygomycete ancestor.
Diffuse radio emission in the complex merging galaxy cluster Abell2069
NASA Astrophysics Data System (ADS)
Drabent, A.; Hoeft, M.; Pizzo, R. F.; Bonafede, A.; van Weeren, R. J.; Klein, U.
2015-03-01
Context. Galaxy clusters with signs of a recent merger in many cases show extended diffuse radio features. This emission originates from relativistic electrons that suffer synchrotron losses due to the intracluster magnetic field. The mechanisms of particle acceleration and the properties of the magnetic field are still poorly understood. Aims: We search for diffuse radio emission in galaxy clusters. Here, we study the complex galaxy cluster Abell 2069, for which X-ray observations indicate a recent merger. Methods: We investigate the cluster's radio continuum emission by deep Westerbork Synthesis Radio Telescope (WSRT) observations at 346 MHz and Giant Metrewave Radio Telescope (GMRT) observations at 322 MHz. Results: We find an extended diffuse radio feature roughly coinciding with the main component of the cluster. We classify this emission as a radio halo and estimate its lower limit flux density at 25 ± 9 mJy. Moreover, we find a second extended diffuse source located at the cluster's companion and estimate its flux density at 15 ± 2 mJy. We speculate that this is a small halo or a mini-halo. If true, this cluster is the first example of a double-halo in a single galaxy cluster.
Finite temperature properties of clusters by replica exchange metadynamics: the water nonamer.
Zhai, Yingteng; Laio, Alessandro; Tosatti, Erio; Gong, Xin-Gao
2011-03-02
We introduce an approach for the accurate calculation of thermal properties of classical nanoclusters. On the basis of a recently developed enhanced sampling technique, replica exchange metadynamics, the method yields the true free energy of each relevant cluster structure, directly sampling its basin and measuring its occupancy in full equilibrium. All entropy sources, whether vibrational, rotational anharmonic, or especially configurational, the latter often forgotten in many cluster studies, are automatically included. For the present demonstration, we choose the water nonamer (H(2)O)(9), an extremely simple cluster, which nonetheless displays a sufficient complexity and interesting physics in its relevant structure spectrum. Within a standard TIP4P potential description of water, we find that the nonamer second relevant structure possesses a higher configurational entropy than the first, so that the two free energies surprisingly cross for increasing temperature.
Finite Temperature Properties of Clusters by Replica Exchange Metadynamics: The Water Nonamer
NASA Astrophysics Data System (ADS)
Zhai, Yingteng; Laio, Alessandro; Tosatti, Erio; Gong, Xingao
2012-02-01
We introduce an approach for the accurate calculation of thermal properties of classical nanoclusters. Based on a recently developed enhanced sampling technique, replica exchange metadynamics, the method yields the true free energy of each relevant cluster structure, directly sampling its basin and measuring its occupancy in full equilibrium. All entropy sources, whether vibrational, rotational anharmonic and especially configurational -- the latter often forgotten in many cluster studies -- are automatically included. For the present demonstration we choose the water nonamer (H2O)9, an extremely simple cluster which nonetheless displays a sufficient complexity and interesting physics in its relevant structure spectrum. Within a standard TIP4P potential description of water, we find that the nonamer second relevant structure possesses a higher configurational entropy than the first, so that the two free energies surprisingly cross for increasing temperature.
3-D Ultrasound Vascularity Assessment for Breast Cancer Diagnosis
2000-09-01
circumscribed mass with no microcalcifications. Final pathologic studies revealed carcinosarcoma (half ductal, half chondrosarcoma ). (a) Lateral-axial...Prostate 2 0 0 2 Angiosarcoma 0 0 2 2 Chondrosarcoma 0 1 0 1 Nasopharyngeal tumor 0 0 1 1 Hemangioendothelioma 0 0 1 1 Renal tumor 1 0 2 3 Baseline...patient with metastatic rendered copper deficient. Table 2 summarizes the clinical chondrosarcoma secondary to radiation treatment for breast course of
Timmerman, Marieke E; Ceulemans, Eva; De Roover, Kim; Van Leeuwen, Karla
2013-12-01
To achieve an insightful clustering of multivariate data, we propose subspace K-means. Its central idea is to model the centroids and cluster residuals in reduced spaces, which allows for dealing with a wide range of cluster types and yields rich interpretations of the clusters. We review the existing related clustering methods, including deterministic, stochastic, and unsupervised learning approaches. To evaluate subspace K-means, we performed a comparative simulation study, in which we manipulated the overlap of subspaces, the between-cluster variance, and the error variance. The study shows that the subspace K-means algorithm is sensitive to local minima but that the problem can be reasonably dealt with by using partitions of various cluster procedures as a starting point for the algorithm. Subspace K-means performs very well in recovering the true clustering across all conditions considered and appears to be superior to its competitor methods: K-means, reduced K-means, factorial K-means, mixtures of factor analyzers (MFA), and MCLUST. The best competitor method, MFA, showed a performance similar to that of subspace K-means in easy conditions but deteriorated in more difficult ones. Using data from a study on parental behavior, we show that subspace K-means analysis provides a rich insight into the cluster characteristics, in terms of both the relative positions of the clusters (via the centroids) and the shape of the clusters (via the within-cluster residuals).
Bianchi, Federico; Praplan, Arnaud P; Sarnela, Nina; Dommen, Josef; Kürten, Andreas; Ortega, Ismael K; Schobesberger, Siegfried; Junninen, Heikki; Simon, Mario; Tröstl, Jasmin; Jokinen, Tuija; Sipilä, Mikko; Adamov, Alexey; Amorim, Antonio; Almeida, Joao; Breitenlechner, Martin; Duplissy, Jonathan; Ehrhart, Sebastian; Flagan, Richard C; Franchin, Alessandro; Hakala, Jani; Hansel, Armin; Heinritzi, Martin; Kangasluoma, Juha; Keskinen, Helmi; Kim, Jaeseok; Kirkby, Jasper; Laaksonen, Ari; Lawler, Michael J; Lehtipalo, Katrianne; Leiminger, Markus; Makhmutov, Vladimir; Mathot, Serge; Onnela, Antti; Petäjä, Tuukka; Riccobono, Francesco; Rissanen, Matti P; Rondo, Linda; Tomé, António; Virtanen, Annele; Viisanen, Yrjö; Williamson, Christina; Wimmer, Daniela; Winkler, Paul M; Ye, Penglin; Curtius, Joachim; Kulmala, Markku; Worsnop, Douglas R; Donahue, Neil M; Baltensperger, Urs
2014-12-02
We investigated the nucleation of sulfuric acid together with two bases (ammonia and dimethylamine), at the CLOUD chamber at CERN. The chemical composition of positive, negative, and neutral clusters was studied using three Atmospheric Pressure interface-Time Of Flight (APi-TOF) mass spectrometers: two were operated in positive and negative mode to detect the chamber ions, while the third was equipped with a nitrate ion chemical ionization source allowing detection of neutral clusters. Taking into account the possible fragmentation that can happen during the charging of the ions or within the first stage of the mass spectrometer, the cluster formation proceeded via essentially one-to-one acid-base addition for all of the clusters, independent of the type of the base. For the positive clusters, the charge is carried by one excess protonated base, while for the negative clusters it is carried by a deprotonated acid; the same is true for the neutral clusters after these have been ionized. During the experiments involving sulfuric acid and dimethylamine, it was possible to study the appearance time for all the clusters (positive, negative, and neutral). It appeared that, after the formation of the clusters containing three molecules of sulfuric acid, the clusters grow at a similar speed, independent of their charge. The growth rate is then probably limited by the arrival rate of sulfuric acid or cluster-cluster collision.
Painless thyroiditis associated to thyroid carcinoma: role of initial ultrasonography evaluation.
Valentini, Raisa Bressan; Macedo, Bruno Mussoi de; Izquierdo, Rogério Friedrich; Meyer, Erika Laurini Souza
2016-04-01
Even though it is a rare event, most associations of thyroid carcinoma with subacute thyroiditis described in the literature are related to its granulomatous form (Quervain's thyroiditis). We present a patient with subacute lymphocytic thyroiditis (painless thyroiditis) and papillary thyroid cancer that was first suspected in an initial ultrasound evaluation. A 30-year old female patient who was referred to the emergency room due to hyperthyroidism symptoms was diagnosed with painless thyroiditis established by physical examination and laboratory findings. With the presence of a palpable painless thyroid nodule an ultrasound was prescribed and the images revealed a suspicious thyroid nodule, microcalcification focus in the heterogeneous thyroid parenquima and cervical lymphadenopathy. Fine needle aspiration biopsy was taken from this nodule; cytology was assessed for compatibility with papillary thyroid carcinoma. Postsurgical pathology evaluation showed a multicentric papillary carcinoma and lymphocytic infiltration. Subacute thyroiditis, regardless of type, may produce transitory ultrasound changes that obscure the coexistence of papillary carcinoma. Due to this, initial thyroid ultrasound evaluation should be delayed until clinical recovery. We recommended a thyroid ultrasound exam for initial evaluation of painless thyroiditis, particularly in patients with palpable thyroid nodule. Further cytological examination is recommended in cases presenting with suspect thyroid nodule and/or non-nodular hypoechoic (> 1 cm) or heterogeneous areas with microcalcification focus.
Janus, Dominika; Wojcik, Malgorzata; Kalicka-Kasperczyk, Anna; Drabik, Grazyna; Wyrobek, Lukasz; Wedrychowicz, Anna; Starzyk, Jerzy B
2017-10-01
The coincidence of autoimmune thyroiditis (AIT) in patients with papillary thyroid carcinoma (PTC) is ranging between 10 and 58% in the general population. In the present study retrospective ultrasound, clinical and autoimmune assessment of 24 patients diagnosed with papillary thyroid carcinoma between 2000-2016 was performed. The coexistence of PTC and AIT was found in 50% of patients with PTC. Patients were divided into two groups. PTC AIT (+) group involved 12 children at the mean age 14.9 years (range 11-20 years, 9 girls) and PTC AIT (-) 12 children at the mean age 12.9 years (range 7-18 years, 5 girls). Papillary thyroid microcarcinoma (PTMC) was diagnosed in 6 patients (in 5 with AIT). US characteristics of PTC was heterogenous: hypoechogenic with/without increased vascularisation, normoechogenic with halo, with/without microcalcifications. In 70% PTC AIT (+) and in all PTC AIT (-) patients ultrasound analysis revealed that the thyroid tissue of the whole gland was normoechogenic. Local metastases in lymph nodes were found in 40% of PTMC AIT (+). Lack of increased vascularization and microcalcifications and presence of``halo`in the nodule does not exclude malignancy. Due to the presence of lymph node involvement in PTMC in all children with PTC total thyroidectomy should be performed with lymph nodes verification.
Correlating the ground truth of mammographic histology with the success or failure of imaging.
Tot, Tibor
2005-02-01
Detailed and systematic mammographic-pathologic correlation is essential for evaluation of the advantages and disadvantages of mammography as an imaging method as well as for establishing the role of additional methods or alternatives. Two- and three-dimensional large section histopathology represents an ideal tool for this correlation. This kind of interdisciplinary approach ("mammographic histology") is slowly but irrevocably becoming accepted as the new golden standard in diagnosing breast abnormalities. In this review, upon summarizing the theoretical background and our practical experience in routine diagnostic use of these advantageous techniques, we report on the accuracy of the preoperative radiological diagnosis. As compared to the final diagnostic outcome, stellate lesions on the mammogram and microcalcifications of casting type indicate malignancy with very high accuracy while predicting malignancy in cases of powdery and crushed stone type microcalcifications is problematic. The extent of the disease is regularly underestimated on the mammogram by the radiologist. Combining different radiological signs, and comparing repeated static images taken in regular intervals in screening or postoperative follow-up, the mammographer may type and grade the lesions properly in a considerable number of cases. Regular mammographic-pathologic correlation may increase the specificity and sensitivity of mammographic diagnosis. This correlation is essential for establishing the proper pre- and postoperative histological diagnosis, too.
Optimizing the maximum reported cluster size in the spatial scan statistic for ordinal data.
Kim, Sehwi; Jung, Inkyung
2017-01-01
The spatial scan statistic is an important tool for spatial cluster detection. There have been numerous studies on scanning window shapes. However, little research has been done on the maximum scanning window size or maximum reported cluster size. Recently, Han et al. proposed to use the Gini coefficient to optimize the maximum reported cluster size. However, the method has been developed and evaluated only for the Poisson model. We adopt the Gini coefficient to be applicable to the spatial scan statistic for ordinal data to determine the optimal maximum reported cluster size. Through a simulation study and application to a real data example, we evaluate the performance of the proposed approach. With some sophisticated modification, the Gini coefficient can be effectively employed for the ordinal model. The Gini coefficient most often picked the optimal maximum reported cluster sizes that were the same as or smaller than the true cluster sizes with very high accuracy. It seems that we can obtain a more refined collection of clusters by using the Gini coefficient. The Gini coefficient developed specifically for the ordinal model can be useful for optimizing the maximum reported cluster size for ordinal data and helpful for properly and informatively discovering cluster patterns.
Optimizing the maximum reported cluster size in the spatial scan statistic for ordinal data
Kim, Sehwi
2017-01-01
The spatial scan statistic is an important tool for spatial cluster detection. There have been numerous studies on scanning window shapes. However, little research has been done on the maximum scanning window size or maximum reported cluster size. Recently, Han et al. proposed to use the Gini coefficient to optimize the maximum reported cluster size. However, the method has been developed and evaluated only for the Poisson model. We adopt the Gini coefficient to be applicable to the spatial scan statistic for ordinal data to determine the optimal maximum reported cluster size. Through a simulation study and application to a real data example, we evaluate the performance of the proposed approach. With some sophisticated modification, the Gini coefficient can be effectively employed for the ordinal model. The Gini coefficient most often picked the optimal maximum reported cluster sizes that were the same as or smaller than the true cluster sizes with very high accuracy. It seems that we can obtain a more refined collection of clusters by using the Gini coefficient. The Gini coefficient developed specifically for the ordinal model can be useful for optimizing the maximum reported cluster size for ordinal data and helpful for properly and informatively discovering cluster patterns. PMID:28753674
Estimating sensitivity and specificity for technology assessment based on observer studies.
Nishikawa, Robert M; Pesce, Lorenzo L
2013-07-01
The goal of this study was to determine the accuracy and precision of using scores from a receiver operating characteristic rating scale to estimate sensitivity and specificity. We used data collected in a previous study that measured the improvements in radiologists' ability to classify mammographic microcalcification clusters as benign or malignant with and without the use of a computer-aided diagnosis scheme. Sensitivity and specificity were estimated from the rating data from a question that directly asked the radiologists their biopsy recommendations, which was used as the "truth," because it is the actual recall decision, thus it is their subjective truth. By thresholding the rating data, sensitivity and specificity were estimated for different threshold values. Because of interreader and intrareader variability, estimated sensitivity and specificity values for individual readers could be as much as 100% in error when using rating data compared to using the biopsy recommendation data. When pooled together, the estimates using thresholding the rating data were in good agreement with sensitivity and specificity estimated from the recommendation data. However, the statistical power of the rating data estimates was lower. By simply asking the observer his or her explicit recommendation (eg, biopsy or no biopsy), sensitivity and specificity can be measured directly, giving a more accurate description of empirical variability and the power of the study can be maximized. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Disability Clustering and Behavior Interactions in Vocational Rehabilitation
ERIC Educational Resources Information Center
Walls, Richard T.
1973-01-01
A sociometric study of 70 male and 32 female vocational rehabilitation clients at the West Virginia Rehabilitation Center concluded that clients with visual, hearing, mental retardation and orthopedic disabilities were found to associate most with others having that same disability; however, this was not true for psychoneurotic clients. (EA)
The OGCleaner: filtering false-positive homology clusters.
Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Snell, Quinn; Bybee, Seth M
2017-01-01
Detecting homologous sequences in organisms is an essential step in protein structure and function prediction, gene annotation and phylogenetic tree construction. Heuristic methods are often employed for quality control of putative homology clusters. These heuristics, however, usually only apply to pairwise sequence comparison and do not examine clusters as a whole. We present the Orthology Group Cleaner (the OGCleaner), a tool designed for filtering putative orthology groups as homology or non-homology clusters by considering all sequences in a cluster. The OGCleaner relies on high-quality orthologous groups identified in OrthoDB to train machine learning algorithms that are able to distinguish between true-positive and false-positive homology groups. This package aims to improve the quality of phylogenetic tree construction especially in instances of lower-quality transcriptome assemblies. https://github.com/byucsl/ogcleaner CONTACT: sfujimoto@gmail.comSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Delrieu, Isabelle; Leboulleux, Didier; Ivinson, Karen; Gessner, Bradford D
2015-03-24
Vaccines interrupting Plasmodium falciparum malaria transmission targeting sexual, sporogonic, or mosquito-stage antigens (SSM-VIMT) are currently under development to reduce malaria transmission. An international group of malaria experts was established to evaluate the feasibility and optimal design of a Phase III cluster randomized trial (CRT) that could support regulatory review and approval of an SSM-VIMT. The consensus design is a CRT with a sentinel population randomly selected from defined inner and buffer zones in each cluster, a cluster size sufficient to assess true vaccine efficacy in the inner zone, and inclusion of ongoing assessment of vaccine impact stratified by distance of residence from the cluster edge. Trials should be conducted first in areas of moderate transmission, where SSM-VIMT impact should be greatest. Sample size estimates suggest that such a trial is feasible, and within the range of previously supported trials of malaria interventions, although substantial issues to implementation exist. Copyright © 2015 Elsevier Ltd. All rights reserved.
VLBA Determination of the Distance to Nearby Star-forming Regions. VIII. The LkHα 101 Cluster
NASA Astrophysics Data System (ADS)
Dzib, Sergio A.; Ortiz-León, Gisela N.; Loinard, L.; Mioduszewski, A. J.; Rodríguez, L. F.; Medina, S.-N. X.; Torres, R. M.
2018-02-01
The LkHα 101 cluster takes its name from its more massive member, the LkHα 101 star, which is an ∼15 M ⊙ star whose true nature is still unknown. The distance to the LkHα 101 cluster has been controversial for the last few decades, with estimated values ranging from 160 to 800 pc. We have observed members and candidate members of the LkHα 101 cluster with signs of magnetic activity, using the Very Long Baseline Array, in order to measure their trigonometric parallax and, thus, obtain a direct measurement of their distances. A young star member, LkHα 101 VLA J043001.15+351724.6, was detected at four epochs as a single radio source. The best fit to its displacement on the plane of the sky yields a distance of 535 ± 29 pc. We argue that this is the distance to the LkHα 101 cluster.
Anders, Katherine L; Cutcher, Zoe; Kleinschmidt, Immo; Donnelly, Christl A; Ferguson, Neil M; Indriani, Citra; O'Neill, Scott L; Jewell, Nicholas P; Simmons, Cameron P
2018-05-07
Cluster randomized trials are the gold standard for assessing efficacy of community-level interventions, such as vector control strategies against dengue. We describe a novel cluster randomized trial methodology with a test-negative design, which offers advantages over traditional approaches. It utilizes outcome-based sampling of patients presenting with a syndrome consistent with the disease of interest, who are subsequently classified as test-positive cases or test-negative controls on the basis of diagnostic testing. We use simulations of a cluster trial to demonstrate validity of efficacy estimates under the test-negative approach. This demonstrates that, provided study arms are balanced for both test-negative and test-positive illness at baseline and that other test-negative design assumptions are met, the efficacy estimates closely match true efficacy. We also briefly discuss analytical considerations for an odds ratio-based effect estimate arising from clustered data, and outline potential approaches to analysis. We conclude that application of the test-negative design to certain cluster randomized trials could increase their efficiency and ease of implementation.
A comparison of heuristic and model-based clustering methods for dietary pattern analysis.
Greve, Benjamin; Pigeot, Iris; Huybrechts, Inge; Pala, Valeria; Börnhorst, Claudia
2016-02-01
Cluster analysis is widely applied to identify dietary patterns. A new method based on Gaussian mixture models (GMM) seems to be more flexible compared with the commonly applied k-means and Ward's method. In the present paper, these clustering approaches are compared to find the most appropriate one for clustering dietary data. The clustering methods were applied to simulated data sets with different cluster structures to compare their performance knowing the true cluster membership of observations. Furthermore, the three methods were applied to FFQ data assessed in 1791 children participating in the IDEFICS (Identification and Prevention of Dietary- and Lifestyle-Induced Health Effects in Children and Infants) Study to explore their performance in practice. The GMM outperformed the other methods in the simulation study in 72 % up to 100 % of cases, depending on the simulated cluster structure. Comparing the computationally less complex k-means and Ward's methods, the performance of k-means was better in 64-100 % of cases. Applied to real data, all methods identified three similar dietary patterns which may be roughly characterized as a 'non-processed' cluster with a high consumption of fruits, vegetables and wholemeal bread, a 'balanced' cluster with only slight preferences of single foods and a 'junk food' cluster. The simulation study suggests that clustering via GMM should be preferred due to its higher flexibility regarding cluster volume, shape and orientation. The k-means seems to be a good alternative, being easier to use while giving similar results when applied to real data.
From hormones to secondary metabolism: the emergence of metabolic gene clusters in plants.
Chu, Hoi Yee; Wegel, Eva; Osbourn, Anne
2011-04-01
Gene clusters for the synthesis of secondary metabolites are a common feature of microbial genomes. Well-known examples include clusters for the synthesis of antibiotics in actinomycetes, and also for the synthesis of antibiotics and toxins in filamentous fungi. Until recently it was thought that genes for plant metabolic pathways were not clustered, and this is certainly true in many cases; however, five plant secondary metabolic gene clusters have now been discovered, all of them implicated in synthesis of defence compounds. An obvious assumption might be that these eukaryotic gene clusters have arisen by horizontal gene transfer from microbes, but there is compelling evidence to indicate that this is not the case. This raises intriguing questions about how widespread such clusters are, what the significance of clustering is, why genes for some metabolic pathways are clustered and those for others are not, and how these clusters form. In answering these questions we may hope to learn more about mechanisms of genome plasticity and adaptive evolution in plants. It is noteworthy that for the five plant secondary metabolic gene clusters reported so far, the enzymes for the first committed steps all appear to have been recruited directly or indirectly from primary metabolic pathways involved in hormone synthesis. This may or may not turn out to be a common feature of plant secondary metabolic gene clusters as new clusters emerge. © 2011 The Authors. The Plant Journal © 2011 Blackwell Publishing Ltd.
Reliability Evaluation for Clustered WSNs under Malware Propagation
Shen, Shigen; Huang, Longjun; Liu, Jianhua; Champion, Adam C.; Yu, Shui; Cao, Qiying
2016-01-01
We consider a clustered wireless sensor network (WSN) under epidemic-malware propagation conditions and solve the problem of how to evaluate its reliability so as to ensure efficient, continuous, and dependable transmission of sensed data from sensor nodes to the sink. Facing the contradiction between malware intention and continuous-time Markov chain (CTMC) randomness, we introduce a strategic game that can predict malware infection in order to model a successful infection as a CTMC state transition. Next, we devise a novel measure to compute the Mean Time to Failure (MTTF) of a sensor node, which represents the reliability of a sensor node continuously performing tasks such as sensing, transmitting, and fusing data. Since clustered WSNs can be regarded as parallel-serial-parallel systems, the reliability of a clustered WSN can be evaluated via classical reliability theory. Numerical results show the influence of parameters such as the true positive rate and the false positive rate on a sensor node’s MTTF. Furthermore, we validate the method of reliability evaluation for a clustered WSN according to the number of sensor nodes in a cluster, the number of clusters in a route, and the number of routes in the WSN. PMID:27294934
Reliability Evaluation for Clustered WSNs under Malware Propagation.
Shen, Shigen; Huang, Longjun; Liu, Jianhua; Champion, Adam C; Yu, Shui; Cao, Qiying
2016-06-10
We consider a clustered wireless sensor network (WSN) under epidemic-malware propagation conditions and solve the problem of how to evaluate its reliability so as to ensure efficient, continuous, and dependable transmission of sensed data from sensor nodes to the sink. Facing the contradiction between malware intention and continuous-time Markov chain (CTMC) randomness, we introduce a strategic game that can predict malware infection in order to model a successful infection as a CTMC state transition. Next, we devise a novel measure to compute the Mean Time to Failure (MTTF) of a sensor node, which represents the reliability of a sensor node continuously performing tasks such as sensing, transmitting, and fusing data. Since clustered WSNs can be regarded as parallel-serial-parallel systems, the reliability of a clustered WSN can be evaluated via classical reliability theory. Numerical results show the influence of parameters such as the true positive rate and the false positive rate on a sensor node's MTTF. Furthermore, we validate the method of reliability evaluation for a clustered WSN according to the number of sensor nodes in a cluster, the number of clusters in a route, and the number of routes in the WSN.
Ecological Consistency of SSU rRNA-Based Operational Taxonomic Units at a Global Scale
Schmidt, Thomas S. B.; Matias Rodrigues, João F.; von Mering, Christian
2014-01-01
Operational Taxonomic Units (OTUs), usually defined as clusters of similar 16S/18S rRNA sequences, are the most widely used basic diversity units in large-scale characterizations of microbial communities. However, it remains unclear how well the various proposed OTU clustering algorithms approximate ‘true’ microbial taxa. Here, we explore the ecological consistency of OTUs – based on the assumption that, like true microbial taxa, they should show measurable habitat preferences (niche conservatism). In a global and comprehensive survey of available microbial sequence data, we systematically parse sequence annotations to obtain broad ecological descriptions of sampling sites. Based on these, we observe that sequence-based microbial OTUs generally show high levels of ecological consistency. However, different OTU clustering methods result in marked differences in the strength of this signal. Assuming that ecological consistency can serve as an objective external benchmark for cluster quality, we conclude that hierarchical complete linkage clustering, which provided the most ecologically consistent partitions, should be the default choice for OTU clustering. To our knowledge, this is the first approach to assess cluster quality using an external, biologically meaningful parameter as a benchmark, on a global scale. PMID:24763141
Improving Spectral Image Classification through Band-Ratio Optimization and Pixel Clustering
NASA Astrophysics Data System (ADS)
O'Neill, M.; Burt, C.; McKenna, I.; Kimblin, C.
2017-12-01
The Underground Nuclear Explosion Signatures Experiment (UNESE) seeks to characterize non-prompt observables from underground nuclear explosions (UNE). As part of this effort, we evaluated the ability of DigitalGlobe's WorldView-3 (WV3) to detect and map UNE signatures. WV3 is the current state-of-the-art, commercial, multispectral imaging satellite; however, it has relatively limited spectral and spatial resolutions. These limitations impede image classifiers from detecting targets that are spatially small and lack distinct spectral features. In order to improve classification results, we developed custom algorithms to reduce false positive rates while increasing true positive rates via a band-ratio optimization and pixel clustering front-end. The clusters resulting from these algorithms were processed with standard spectral image classifiers such as Mixture-Tuned Matched Filter (MTMF) and Adaptive Coherence Estimator (ACE). WV3 and AVIRIS data of Cuprite, Nevada, were used as a validation data set. These data were processed with a standard classification approach using MTMF and ACE algorithms. They were also processed using the custom front-end prior to the standard approach. A comparison of the results shows that the custom front-end significantly increases the true positive rate and decreases the false positive rate.This work was done by National Security Technologies, LLC, under Contract No. DE-AC52-06NA25946 with the U.S. Department of Energy. DOE/NV/25946-3283.
Aggarwal, Ashim; Sarmiento, Joseph J; Charles, David R; Parr, Alan R; Baman, Timir S
2016-04-01
Device failure from unanticipated and precipitous battery depletion is uncommon but can be life-threatening. Multiple mechanisms of battery failure have been previously described in the medical literature. However, in this current case series, we describe the largest cohort of patients (n = 4) with St. Jude (St. Paul, MN, USA) early implantable defibrillator battery depletion attributable to lithium cluster formation causing short circuit and high current drain. Clinicians must be aware of this occult cause of device failure and more studies are needed to determine its true prevalence. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Wisniewski, J. P.; Bjorkman, K. S.; Magalhaes, A. M.; Bjorkman, J. E.; Meade, M. R.; Pereyra, Antonio
2007-01-01
Photometric 2-color diagram (2-CD) surveys of young cluster populations have been used to identify populations of B-type stars exhibiting excess Ha emission. The prevalence of these excess emitters, assumed to be "Be stars". has led to the establishment of links between the onset of disk formation in classical Be stars and cluster age and/or metallicity. We have obtained imaging polarization observations of six SMC and six LMC clusters whose candidate Be populations had been previously identified via 2-CDs. The interstellar polarization (ISP) associated with these data has been identified to facilitate an examination of the circumstellar environments of these candidate Be stars via their intrinsic polarization signatures, hence determine the true nature of these objects. We determined that the ISP associated with the SMC cluster NGC 330 was characterized by a modified Serkowski law with a lambda(sub max) of approx. 4500Angstroms, indicating the presence of smaller than average dust grains. The morphology of the ISP associated with the LMC cluster NGC 2100 suggests that its interstellar environment is characterized by a complex magnetic field. Our intrinsic polarization results confirm the suggestion of Wisniewski et al. that a substantial number of bona-fide classical Be stars are present in clusters of age 5-8 Myr. Hence, our data contradict recent assertions that the Be phenomenon develops in the second half of a B star's main sequence lifetime, i.e. no earlier than 10 Myr. These data imply that a significant number of B-type stars must emerge onto the zero-age-main-sequence rotating at near-critical rotation rates, although we can not rule out the possibility that these data instead reveal the presence of a sub-group of the Be phenomenon characterized by sub-critically rotating objects. Comparing the polarimetric properties of our dataset to a similar survey of Galactic classical Be stars, we find that the prevalence of polarimetric Balmer jump signatures decreases with metallicity. We speculate that these results might indicate that either it is more difficult to form large disk systems in low metallicity environments, or that the average disk temperature is higher in these low metallicity environments. We have characterized the polarimetric signatures of all candidate Be stars in our data sample and find approx. 25% are unlikely to arise from true classical Be star-disk systems. This detection of such a substantial number "contaminants" suggests one should proceed with caution when attempting to determine the role of evolutionary age and/or metallicity in the Be phenomenon purely via 2-CD results.
Study on computer-aided diagnosis of hepatic MR imaging and mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Xuejun
2005-04-01
It is well known that the liver is an organ easily attacked by diseases. The purpose of this study is to develop a computer-aided diagnosis (CAD) scheme for helping radiologists to differentiate hepatic diseases more efficiently. Our software named LIVERANN integrated the magnetic resonance (MR) imaging findings with different pulse sequences to classify the five categories of hepatic diseases by using the artificial neural network (ANN) method. The intensity and homogeneity within the region of interest (ROI) delineated by a radiologist were automatically calculated to obtain numerical data by the program for input signals to the ANN. Outputs were themore » five pathological categories of hepatic diseases (hepatic cyst, hepatocellular carcinoma, dysplasia in cirrhosis, cavernous hemangioma, and metastasis). The experiment demonstrated a testing accuracy of 93% from 80 patients. In order to differentiate the cirrhosis from normal liver, the volume ratio of left to whole (LTW) was proposed to quantify the degree of cirrhosis by three-dimensional (3D) volume analysis. The liver region was firstly extracted from computed tomography (CT) or MR slices based on edge detection algorithms, and then separated into left lobe and right lobe by the hepatic umbilical fissure. The volume ratio of these two parts showed that the LTW ratio in the liver was significantly improved in the differentiation performance, with (25.6%{+-}4.3%) in cirrhosis versus the normal liver (16.4%{+-}5.4%). In addition, the application of the ANN method for detecting clustered microcalcifications in masses on mammograms was described here as well. A new structural ANN, so-called a shift-invariant artificial neural network (SIANN), was integrated with our triple-ring filter (TRF) method in our CAD system. As the result, the sensitivity of detecting clusters was improved from 90% by our previous TRF method to 95% by using both SIANN and TRF.« less
Old, L.; Wojtak, R.; Pearce, F. R.; ...
2017-12-20
With the advent of wide-field cosmological surveys, we are approaching samples of hundreds of thousands of galaxy clusters. While such large numbers will help reduce statistical uncertainties, the control of systematics in cluster masses is crucial. Here we examine the effects of an important source of systematic uncertainty in galaxy-based cluster mass estimation techniques: the presence of significant dynamical substructure. Dynamical substructure manifests as dynamically distinct subgroups in phase-space, indicating an ‘unrelaxed’ state. This issue affects around a quarter of clusters in a generally selected sample. We employ a set of mock clusters whose masses have been measured homogeneously withmore » commonly used galaxy-based mass estimation techniques (kinematic, richness, caustic, radial methods). We use these to study how the relation between observationally estimated and true cluster mass depends on the presence of substructure, as identified by various popular diagnostics. We find that the scatter for an ensemble of clusters does not increase dramatically for clusters with dynamical substructure. However, we find a systematic bias for all methods, such that clusters with significant substructure have higher measured masses than their relaxed counterparts. This bias depends on cluster mass: the most massive clusters are largely unaffected by the presence of significant substructure, but masses are significantly overestimated for lower mass clusters, by ~ 10 percent at 10 14 and ≳ 20 percent for ≲ 10 13.5. Finally, the use of cluster samples with different levels of substructure can therefore bias certain cosmological parameters up to a level comparable to the typical uncertainties in current cosmological studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Old, L.; Wojtak, R.; Pearce, F. R.
With the advent of wide-field cosmological surveys, we are approaching samples of hundreds of thousands of galaxy clusters. While such large numbers will help reduce statistical uncertainties, the control of systematics in cluster masses is crucial. Here we examine the effects of an important source of systematic uncertainty in galaxy-based cluster mass estimation techniques: the presence of significant dynamical substructure. Dynamical substructure manifests as dynamically distinct subgroups in phase-space, indicating an ‘unrelaxed’ state. This issue affects around a quarter of clusters in a generally selected sample. We employ a set of mock clusters whose masses have been measured homogeneously withmore » commonly used galaxy-based mass estimation techniques (kinematic, richness, caustic, radial methods). We use these to study how the relation between observationally estimated and true cluster mass depends on the presence of substructure, as identified by various popular diagnostics. We find that the scatter for an ensemble of clusters does not increase dramatically for clusters with dynamical substructure. However, we find a systematic bias for all methods, such that clusters with significant substructure have higher measured masses than their relaxed counterparts. This bias depends on cluster mass: the most massive clusters are largely unaffected by the presence of significant substructure, but masses are significantly overestimated for lower mass clusters, by ~ 10 percent at 10 14 and ≳ 20 percent for ≲ 10 13.5. Finally, the use of cluster samples with different levels of substructure can therefore bias certain cosmological parameters up to a level comparable to the typical uncertainties in current cosmological studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sills, Alison; Glebbeek, Evert; Chatterjee, Sourav
We created artificial color-magnitude diagrams of Monte Carlo dynamical models of globular clusters and then used observational methods to determine the number of blue stragglers in those clusters. We compared these blue stragglers to various cluster properties, mimicking work that has been done for blue stragglers in Milky Way globular clusters to determine the dominant formation mechanism(s) of this unusual stellar population. We find that a mass-based prescription for selecting blue stragglers will select approximately twice as many blue stragglers than a selection criterion that was developed for observations of real clusters. However, the two numbers of blue stragglers aremore » well-correlated, so either selection criterion can be used to characterize the blue straggler population of a cluster. We confirm previous results that the simplified prescription for the evolution of a collision or merger product in the BSE code overestimates their lifetimes. We show that our model blue stragglers follow similar trends with cluster properties (core mass, binary fraction, total mass, collision rate) as the true Milky Way blue stragglers as long as we restrict ourselves to model clusters with an initial binary fraction higher than 5%. We also show that, in contrast to earlier work, the number of blue stragglers in the cluster core does have a weak dependence on the collisional parameter Γ in both our models and in Milky Way globular clusters.« less
NASA Astrophysics Data System (ADS)
Alexeyev, S. O.; Latosh, B. N.; Echeistov, V. A.
2017-12-01
Predictions of the f( R)-gravity model with a disappearing cosmological constant (Starobinsky's model) on scales characteristic of galaxies and their clusters are considered. The absence of a difference in the mass dependence of the turnaround radius between Starobinsky's model and General Relativity accessible to observation at the current accuracy of measurements has been established. This is true both for small masses (from 109 M Sun) corresponding to an individual galaxy and for masses corresponding to large galaxy clusters (up to 1015 M Sun). The turnaround radius increases with parameter n for all masses. Despite the fact that some models give a considerably smaller turnaround radius than does General Relativity, none of the models goes beyond the bounds specified by the observational data.
Thompson, Damien; Hermes, Jens P; Quinn, Aidan J; Mayor, Marcel
2012-04-24
The formation of true single-molecule complexes between organic ligands and nanoparticles is challenging and requires careful design of molecules with size, shape, and chemical properties tailored for the specific nanoparticle. Here we use computer simulations to describe the atomic-scale structure, dynamics, and energetics of ligand-mediated synthesis and interlinking of 1 nm gold clusters. The models help explain recent experimental results and provide insight into how multidentate thioether dendrimers can be employed for synthesis of true single-ligand-nanoparticle complexes and also nanoparticle-molecule-nanoparticle "dumbbell" nanostructures. Electronic structure calculations reveal the individually weak thioether-gold bonds (325 ± 36 meV), which act collectively through the multivalent (multisite) anchoring to stabilize the ligand-nanoparticle complex (∼7 eV total binding energy) and offset the conformational and solvation penalties involved in this "wrapping" process. Molecular dynamics simulations show that the dendrimer is sufficiently flexible to tolerate the strained conformations and desolvation penalties involved in fully wrapping the particle, quantifying the subtle balance between covalent anchoring and noncovalent wrapping in the assembly of ligand-nanoparticle complexes. The computed preference for binding of a single dendrimer to the cluster reveals the prohibitively high dendrimer desolvation barrier (1.5 ± 0.5 eV) to form the alternative double-dendrimer structure. Finally, the models show formation of an additional electron transfer channel between nitrogen and gold for ligands with a central pyridine unit, which gives a stiff binding orientation and explains the recently measured larger interparticle distances for particles synthesized and interlinked using linear ligands with a central pyridine rather than a benzene moiety. The findings stress the importance of organic-inorganic interactions, the control of which is central to the rational engineering and eventual large-scale production of functional building blocks for nano(bio)electronics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braga, V. F.; Bono, G.; Buonanno, R.
2015-02-01
We present new distance determinations to the nearby globular M4 (NGC 6121) based on accurate optical and near-infrared (NIR) mean magnitudes for fundamental (FU) and first overtone (FO) RR Lyrae variables (RRLs), and new empirical optical and NIR period-luminosity (PL) and period-Wesenheit (PW) relations. We have found that optical-NIR and NIR PL and PW relations are affected by smaller standard deviations than optical relations. The difference is the consequence of a steady decrease in the intrinsic spread of cluster RRL apparent magnitudes at fixed period as longer wavelengths are considered. The weighted mean visual apparent magnitude of 44 cluster RRLs ismore » =13.329 ± 0.001 (standard error of the mean) ±0.177 (weighted standard deviation) mag. Distances were estimated using RR Lyr itself to fix the zero-point of the empirical PL and PW relations. Using the entire sample (FU+FO) we found weighted mean true distance moduli of 11.35 ± 0.03 ± 0.05 mag and 11.32 ± 0.02 ± 0.07 mag. Distances were also evaluated using predicted metallicity dependent PLZ and PWZ relations. We found weighted mean true distance moduli of 11.283 ± 0.010 ± 0.018 mag (NIR PLZ) and 11.272 ± 0.005 ± 0.019 mag (optical-NIR and NIR PWZ). The above weighted mean true distance moduli agree within 1σ. The same result is found from distances based on PWZ relations in which the color index is independent of the adopted magnitude (11.272 ± 0.004 ± 0.013 mag). These distances agree quite well with the geometric distance provided by Kaluzny et al. based on three eclipsing binaries. The available evidence indicates that this approach can provide distances to globulars hosting RRLs with a precision better than 2%-3%.« less
Computer Aided Detection of Microcalcifications Utilizing Texture Analysis
1995-12-01
encouraging results using features derived from the first moment of the power spectrum of the region[13]. Chitre, et al. and Kocur have made use of...are largely concentrated around the main diagonal. For the example C matrix in Figure 3.11, the ASM value is 0.0972. Previous work by Kocur [17] and...Patterson AFB OH, 1994. BIB-1 16. Hoffmeister, Jeffery W. Personal interviews, May-Nov 1995. Aerospace Physician. AL/CFHV, Wright-Patterson AFB,OH. 17. Kocur
Transient Fourier holography with bacteriorhodopsin films for breast cancer diagnostics
NASA Astrophysics Data System (ADS)
Rao, Devulapalli; Kothapalli, Sri-Rajasekar; Wu, Pengfei; Yelleswarapu, Chandra
X-ray mammography is the current gold standard for breast cancer screening. Microcalcifications and other features which are helpful to the radiologist for early diagnostics are often buried in the noise generated by the surrounding dense tissue. So image processing techniques are required to enhance these important features to improve the sensitivity of detection. An innovative technique is demonstrated for recording a hologram of the mammogram. It is recorded on a thin polymer film of Bacteriorhodopsin (bR) as photo induced isomerization grating containing the interference pattern between the object beam containing the Fourier spatial frequency components of the mammogram and a reference beam. The hologram contains all the enhanced features of the mammogram. A significant innovation of the technique is that the enhanced components in the processed image can be viewed by the radiologist in time scale. A technician can record the movie and when the radiologist looks at the movie at his convenience, freezing the frame as and when desired, he would see the microcalcifications as the brightest and last long in time. He would also observe lesions with intensity decreasing as their size increases. The same bR film can be used repeatedly for recording holograms with different mammograms. The technique is versatile and a different frequency band can be chosen to be optimized by changing the reference beam intensity. The experimental arrangement can be used for mammograms in screen film or digital format.
Analysis of classifiers performance for classification of potential microcalcification
NASA Astrophysics Data System (ADS)
M. N., Arun K.; Sheshadri, H. S.
2013-07-01
Breast cancer is a significant public health problem in the world. According to the literature early detection improve breast cancer prognosis. Mammography is a screening tool used for early detection of breast cancer. About 10-30% cases are missed during the routine check as it is difficult for the radiologists to make accurate analysis due to large amount of data. The Microcalcifications (MCs) are considered to be important signs of breast cancer. It has been reported in literature that 30% - 50% of breast cancer detected radio graphically show MCs on mammograms. Histologic examinations report 62% to 79% of breast carcinomas reveals MCs. MC are tiny, vary in size, shape, and distribution, and MC may be closely connected to surrounding tissues. There is a major challenge using the traditional classifiers in the classification of individual potential MCs as the processing of mammograms in appropriate stage generates data sets with an unequal amount of information for both classes (i.e., MC, and Not-MC). Most of the existing state-of-the-art classification approaches are well developed by assuming the underlying training set is evenly distributed. However, they are faced with a severe bias problem when the training set is highly imbalanced in distribution. This paper addresses this issue by using classifiers which handle the imbalanced data sets. In this paper, we also compare the performance of classifiers which are used in the classification of potential MC.
Cox, R F; Hernandez-Santana, A; Ramdass, S; McMahon, G; Harmey, J H; Morgan, M P
2012-01-01
Background: Mammographic microcalcifications represent one of the most reliable features of nonpalpable breast cancer yet remain largely unexplored and poorly understood. Methods: We report a novel model to investigate the in vitro mineralisation potential of a panel of mammary cell lines. Primary mammary tumours were produced by implanting tumourigenic cells into the mammary fat pads of female BALB/c mice. Results: Hydroxyapatite (HA) was deposited only by the tumourigenic cell lines, indicating mineralisation potential may be associated with cell phenotype in this in vitro model. We propose a mechanism for mammary mineralisation, which suggests that the balance between enhancers and inhibitors of physiological mineralisation are disrupted. Inhibition of alkaline phosphatase and phosphate transport prevented mineralisation, demonstrating that mineralisation is an active cell-mediated process. Hydroxyapatite was found to enhance in vitro tumour cell migration, while calcium oxalate had no effect, highlighting potential consequences of calcium deposition. In addition, HA was also deposited in primary mammary tumours produced by implanting the tumourigenic cells into the mammary fat pads of female BALB/c mice. Conclusion: This work indicates that formation of mammary HA is a cell-specific regulated process, which creates an osteomimetic niche potentially enhancing breast tumour progression. Our findings point to the cells mineralisation potential and the microenvironment regulating it, as a significant feature of breast tumour development. PMID:22233923
NASA Astrophysics Data System (ADS)
Roehrig, Hans; Fan, Jiahua; Dallas, William J.; Krupinski, Elizabeth A.; Johnson, Jeffrey
2009-08-01
This presentation describes work in progress that is the result of an NIH SBIR Phase 1 project that addresses the wide- spread concern for the large number of breast-cancers and cancer victims [1,2]. The primary goal of the project is to increase the detection rate of microcalcifications as a result of the decrease of spatial noise of the LCDs used to display the mammograms [3,4]. Noise reduction is to be accomplished with the aid of a high performance CCD camera and subsequent application of local-mean equalization and error diffusion [5,6]. A second goal of the project is the actual detection of breast cancer. Contrary to the approach to mammography, where the mammograms typically have a pixel matrix of approximately 1900 x 2300 pixels, otherwise known as FFDM or Full-Field Digital Mammograms, we will only use sections of mammograms with a pixel matrix of 256 x 256 pixels. This is because at this time, reduction of spatial noise on an LCD can only be done on relatively small areas like 256 x 256 pixels. In addition, judging the efficacy for detection of breast cancer will be done using two methods: One is a conventional ROC study [7], the other is a vision model developed over several years starting at the Sarnoff Research Center and continuing at the Siemens Corporate Research in Princeton NJ [8].
Karnan, M; Thangavel, K
2007-07-01
The presence of microcalcifications in breast tissue is one of the most incident signs considered by radiologist for an early diagnosis of breast cancer, which is one of the most common forms of cancer among women. In this paper, the Genetic Algorithm (GA) is proposed for automatic look at commonly prone area the breast border and nipple position to discover the suspicious regions on digital mammograms based on asymmetries between left and right breast image. The basic idea of the asymmetry approach is to scan left and right images are subtracted to extract the suspicious region. The proposed system consists of two steps: First, the mammogram images are enhanced using median filter, normalize the image, at the pectoral muscle region is excluding the border of the mammogram and comparing for both left and right images from the binary image. Further GA is applied to magnify the detected border. The figure of merit is calculated to evaluate whether the detected border is exact or not. And the nipple position is identified using GA. The some comparisons method is adopted for detection of suspected area. Second, using the border points and nipple position as the reference the mammogram images are aligned and subtracted to extract the suspicious region. The algorithms are tested on 114 abnormal digitized mammograms from Mammogram Image Analysis Society database.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berlind, Andreas A.; Frieman, Joshua A.; Weinberg, David H.
2006-01-01
We identify galaxy groups and clusters in volume-limited samples of the SDSS redshift survey, using a redshift-space friends-of-friends algorithm. We optimize the friends-of-friends linking lengths to recover galaxy systems that occupy the same dark matter halos, using a set of mock catalogs created by populating halos of N-body simulations with galaxies. Extensive tests with these mock catalogs show that no combination of perpendicular and line-of-sight linking lengths is able to yield groups and clusters that simultaneously recover the true halo multiplicity function, projected size distribution, and velocity dispersion. We adopt a linking length combination that yields, for galaxy groups withmore » ten or more members: a group multiplicity function that is unbiased with respect to the true halo multiplicity function; an unbiased median relation between the multiplicities of groups and their associated halos; a spurious group fraction of less than {approx}1%; a halo completeness of more than {approx}97%; the correct projected size distribution as a function of multiplicity; and a velocity dispersion distribution that is {approx}20% too low at all multiplicities. These results hold over a range of mock catalogs that use different input recipes of populating halos with galaxies. We apply our group-finding algorithm to the SDSS data and obtain three group and cluster catalogs for three volume-limited samples that cover 3495.1 square degrees on the sky. We correct for incompleteness caused by fiber collisions and survey edges, and obtain measurements of the group multiplicity function, with errors calculated from realistic mock catalogs. These multiplicity function measurements provide a key constraint on the relation between galaxy populations and dark matter halos.« less
Biased phylodynamic inferences from analysing clusters of viral sequences
Xiang, Fei; Frost, Simon D. W.
2017-01-01
Abstract Phylogenetic methods are being increasingly used to help understand the transmission dynamics of measurably evolving viruses, including HIV. Clusters of highly similar sequences are often observed, which appear to follow a ‘power law’ behaviour, with a small number of very large clusters. These clusters may help to identify subpopulations in an epidemic, and inform where intervention strategies should be implemented. However, clustering of samples does not necessarily imply the presence of a subpopulation with high transmission rates, as groups of closely related viruses can also occur due to non-epidemiological effects such as over-sampling. It is important to ensure that observed phylogenetic clustering reflects true heterogeneity in the transmitting population, and is not being driven by non-epidemiological effects. We qualify the effect of using a falsely identified ‘transmission cluster’ of sequences to estimate phylodynamic parameters including the effective population size and exponential growth rate under several demographic scenarios. Our simulation studies show that taking the maximum size cluster to re-estimate parameters from trees simulated under a randomly mixing, constant population size coalescent process systematically underestimates the overall effective population size. In addition, the transmission cluster wrongly resembles an exponential or logistic growth model 99% of the time. We also illustrate the consequences of false clusters in exponentially growing coalescent and birth-death trees, where again, the growth rate is skewed upwards. This has clear implications for identifying clusters in large viral databases, where a false cluster could result in wasted intervention resources. PMID:28852573
THE XMM CLUSTER SURVEY: THE STELLAR MASS ASSEMBLY OF FOSSIL GALAXIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, Craig D.; Miller, Christopher J.; Richards, Joseph W.
This paper presents both the result of a search for fossil systems (FSs) within the XMM Cluster Survey and the Sloan Digital Sky Survey and the results of a study of the stellar mass assembly and stellar populations of their fossil galaxies. In total, 17 groups and clusters are identified at z < 0.25 with large magnitude gaps between the first and fourth brightest galaxies. All the information necessary to classify these systems as fossils is provided. For both groups and clusters, the total and fractional luminosity of the brightest galaxy is positively correlated with the magnitude gap. The brightestmore » galaxies in FSs (called fossil galaxies) have stellar populations and star formation histories which are similar to normal brightest cluster galaxies (BCGs). However, at fixed group/cluster mass, the stellar masses of the fossil galaxies are larger compared to normal BCGs, a fact that holds true over a wide range of group/cluster masses. Moreover, the fossil galaxies are found to contain a significant fraction of the total optical luminosity of the group/cluster within 0.5 R{sub 200}, as much as 85%, compared to the non-fossils, which can have as little as 10%. Our results suggest that FSs formed early and in the highest density regions of the universe and that fossil galaxies represent the end products of galaxy mergers in groups and clusters.« less
Star cluster formation history along the minor axis of the Large Magellanic Cloud
NASA Astrophysics Data System (ADS)
Piatti, Andrés E.; Cole, Andrew A.; Emptage, Bryn
2018-01-01
We analysed Washington CMT1 photometry of star clusters located along the minor axis of the Large Magellanic Cloud (LMC), from the LMC optical centre up to ∼39° outwards to the North-West. The data base was exploited in order to search for new star cluster candidates, to produce cluster CMDs cleaned from field star contamination and to derive age estimates for a statistically complete cluster sample. We confirmed that 146 star cluster candidates are genuine physical systems, and concluded that an overall ∼30 per cent of catalogued clusters in the surveyed regions are unlikely to be true physical systems. We did not find any new cluster candidates in the outskirts of the LMC (deprojected distance ≳ 8°). The derived ages of the studied clusters are in the range 7.2 < log(t yr-1) ≤ 9.4, with the sole exception of the globular cluster NGC 1786 (log(t yr-1) = 10.10). We also calculated the cluster frequency for each region, from which we confirmed previously proposed outside-in formation scenarios. In addition, we found that the outer LMC fields show a sudden episode of cluster formation (log(t yr-1) ∼7.8-7.9) which continued until log(t yr-1) ∼7.3 only in the outermost LMC region. We link these features to the first pericentre passage of the LMC to the Milky Way (MW), which could have triggered cluster formation due to ram pressure interaction between the LMC and MW halo.
Using Design-Based Latent Growth Curve Modeling with Cluster-Level Predictor to Address Dependency
ERIC Educational Resources Information Center
Wu, Jiun-Yu; Kwok, Oi-Man; Willson, Victor L.
2014-01-01
The authors compared the effects of using the true Multilevel Latent Growth Curve Model (MLGCM) with single-level regular and design-based Latent Growth Curve Models (LGCM) with or without the higher-level predictor on various criterion variables for multilevel longitudinal data. They found that random effect estimates were biased when the…
Identifying and Assessing Interesting Subgroups in a Heterogeneous Population.
Lee, Woojoo; Alexeyenko, Andrey; Pernemalm, Maria; Guegan, Justine; Dessen, Philippe; Lazar, Vladimir; Lehtiö, Janne; Pawitan, Yudi
2015-01-01
Biological heterogeneity is common in many diseases and it is often the reason for therapeutic failures. Thus, there is great interest in classifying a disease into subtypes that have clinical significance in terms of prognosis or therapy response. One of the most popular methods to uncover unrecognized subtypes is cluster analysis. However, classical clustering methods such as k-means clustering or hierarchical clustering are not guaranteed to produce clinically interesting subtypes. This could be because the main statistical variability--the basis of cluster generation--is dominated by genes not associated with the clinical phenotype of interest. Furthermore, a strong prognostic factor might be relevant for a certain subgroup but not for the whole population; thus an analysis of the whole sample may not reveal this prognostic factor. To address these problems we investigate methods to identify and assess clinically interesting subgroups in a heterogeneous population. The identification step uses a clustering algorithm and to assess significance we use a false discovery rate- (FDR-) based measure. Under the heterogeneity condition the standard FDR estimate is shown to overestimate the true FDR value, but this is remedied by an improved FDR estimation procedure. As illustrations, two real data examples from gene expression studies of lung cancer are provided.
Finding reproducible cluster partitions for the k-means algorithm
2013-01-01
K-means clustering is widely used for exploratory data analysis. While its dependence on initialisation is well-known, it is common practice to assume that the partition with lowest sum-of-squares (SSQ) total i.e. within cluster variance, is both reproducible under repeated initialisations and also the closest that k-means can provide to true structure, when applied to synthetic data. We show that this is generally the case for small numbers of clusters, but for values of k that are still of theoretical and practical interest, similar values of SSQ can correspond to markedly different cluster partitions. This paper extends stability measures previously presented in the context of finding optimal values of cluster number, into a component of a 2-d map of the local minima found by the k-means algorithm, from which not only can values of k be identified for further analysis but, more importantly, it is made clear whether the best SSQ is a suitable solution or whether obtaining a consistently good partition requires further application of the stability index. The proposed method is illustrated by application to five synthetic datasets replicating a real world breast cancer dataset with varying data density, and a large bioinformatics dataset. PMID:23369085
Finding reproducible cluster partitions for the k-means algorithm.
Lisboa, Paulo J G; Etchells, Terence A; Jarman, Ian H; Chambers, Simon J
2013-01-01
K-means clustering is widely used for exploratory data analysis. While its dependence on initialisation is well-known, it is common practice to assume that the partition with lowest sum-of-squares (SSQ) total i.e. within cluster variance, is both reproducible under repeated initialisations and also the closest that k-means can provide to true structure, when applied to synthetic data. We show that this is generally the case for small numbers of clusters, but for values of k that are still of theoretical and practical interest, similar values of SSQ can correspond to markedly different cluster partitions. This paper extends stability measures previously presented in the context of finding optimal values of cluster number, into a component of a 2-d map of the local minima found by the k-means algorithm, from which not only can values of k be identified for further analysis but, more importantly, it is made clear whether the best SSQ is a suitable solution or whether obtaining a consistently good partition requires further application of the stability index. The proposed method is illustrated by application to five synthetic datasets replicating a real world breast cancer dataset with varying data density, and a large bioinformatics dataset.
2009-04-01
reviewed Journal Articles 1. D. Xia, L. Yu , E. Y. Sidky, Y. Zou, N. Zuo, and X. Pan: Noise properties of chord-image reconstruction, IEEE Transaction...on Medical Imaging 26, pp. 1328-1344, 2007. Conference Proceeding Articles 1. D. Xia, E. Y. Sidky, L. Yu , and X. Pan: Noise properties in helical...positions distributed over a surface, Proc. SPIE, Vol. 6913, pp. 69132A, 2008. 11. D. Xia, L. Yu , E. Y. Sidky, Y. Zou, N. Zuo, and X. Pan: Noise properties
Acoustic Inverse Scattering for Breast Cancer Microcalcification Detection. Addendum
2011-12-01
the center. To conserve space, few are shown here. A graph comparing the spatial location and the error in reconstruction will follow...following graphs show the error in reconstruction as a function of position of the object along the x-axis, y-axis and the diagonal in the fourth quadrant of...the well-known Kirchhoff – Poisson formulas (see, e.g., Refs. [33,34]) allow one to rep- resent the solution p(x,t) in terms of the spherical means
Calibrating First-Order Strong Lensing Mass Estimates in Clusters of Galaxies
NASA Astrophysics Data System (ADS)
Reed, Brendan; Remolian, Juan; Sharon, Keren; Li, Nan; SPT Clusters Cooperation
2018-01-01
We investigate methods to reduce the statistical and systematic errors inherent to using the Einstein Radius as a first-order mass estimate in strong lensing galaxy clusters. By finding an empirical universal calibration function, we aim to enable a first-order mass estimate of large cluster data sets in a fraction of the time and effort of full-scale strong lensing mass modeling. We use 74 simulated cluster data from the Argonne National Laboratory in a lens redshift slice of [0.159, 0.667] with various source redshifts in the range of [1.23, 2.69]. From the simulated density maps, we calculate the exact mass enclosed within the Einstein Radius. We find that the mass inferred from the Einstein Radius alone produces an error width of ~39% with respect to the true mass. We explore an array of polynomial and exponential correction functions with dependence on cluster redshift and projected radii of the lensed images, aiming to reduce the statistical and systematic uncertainty. We find that the error on the the mass inferred from the Einstein Radius can be reduced significantly by using a universal correction function. Our study has implications for current and future large galaxy cluster surveys aiming to measure cluster mass, and the mass-concentration relation.
Relating Measurement Invariance, Cross-Level Invariance, and Multilevel Reliability.
Jak, Suzanne; Jorgensen, Terrence D
2017-01-01
Data often have a nested, multilevel structure, for example when data are collected from children in classrooms. This kind of data complicate the evaluation of reliability and measurement invariance, because several properties can be evaluated at both the individual level and the cluster level, as well as across levels. For example, cross-level invariance implies equal factor loadings across levels, which is needed to give latent variables at the two levels a similar interpretation. Reliability at a specific level refers to the ratio of true score variance over total variance at that level. This paper aims to shine light on the relation between reliability, cross-level invariance, and strong factorial invariance across clusters in multilevel data. Specifically, we will illustrate how strong factorial invariance across clusters implies cross-level invariance and perfect reliability at the between level in multilevel factor models.
NASA Astrophysics Data System (ADS)
Kawahara, Hajime; Reese, Erik D.; Kitayama, Tetsu; Sasaki, Shin; Suto, Yasushi
2008-11-01
Our previous analysis indicates that small-scale fluctuations in the intracluster medium (ICM) from cosmological hydrodynamic simulations follow the lognormal probability density function. In order to test the lognormal nature of the ICM directly against X-ray observations of galaxy clusters, we develop a method of extracting statistical information about the three-dimensional properties of the fluctuations from the two-dimensional X-ray surface brightness. We first create a set of synthetic clusters with lognormal fluctuations around their mean profile given by spherical isothermal β-models, later considering polytropic temperature profiles as well. Performing mock observations of these synthetic clusters, we find that the resulting X-ray surface brightness fluctuations also follow the lognormal distribution fairly well. Systematic analysis of the synthetic clusters provides an empirical relation between the three-dimensional density fluctuations and the two-dimensional X-ray surface brightness. We analyze Chandra observations of the galaxy cluster Abell 3667, and find that its X-ray surface brightness fluctuations follow the lognormal distribution. While the lognormal model was originally motivated by cosmological hydrodynamic simulations, this is the first observational confirmation of the lognormal signature in a real cluster. Finally we check the synthetic cluster results against clusters from cosmological hydrodynamic simulations. As a result of the complex structure exhibited by simulated clusters, the empirical relation between the two- and three-dimensional fluctuation properties calibrated with synthetic clusters when applied to simulated clusters shows large scatter. Nevertheless we are able to reproduce the true value of the fluctuation amplitude of simulated clusters within a factor of 2 from their two-dimensional X-ray surface brightness alone. Our current methodology combined with existing observational data is useful in describing and inferring the statistical properties of the three-dimensional inhomogeneity in galaxy clusters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geller, Aaron M.; Hurley, Jarrod R.; Mathieu, Robert D., E-mail: a-geller@northwestern.edu, E-mail: mathieu@astro.wisc.edu, E-mail: jhurley@astro.swin.edu.au
2013-01-01
Following on from a recently completed radial-velocity survey of the old (7 Gyr) open cluster NGC 188 in which we studied in detail the solar-type hard binaries and blue stragglers of the cluster, here we investigate the dynamical evolution of NGC 188 through a sophisticated N-body model. Importantly, we employ the observed binary properties of the young (180 Myr) open cluster M35, where possible, to guide our choices for parameters of the initial binary population. We apply pre-main-sequence tidal circularization and a substantial increase to the main-sequence tidal circularization rate, both of which are necessary to match the observed tidalmore » circularization periods in the literature, including that of NGC 188. At 7 Gyr the main-sequence solar-type hard-binary population in the model matches that of NGC 188 in both binary frequency and distributions of orbital parameters. This agreement between the model and observations is in a large part due to the similarities between the NGC 188 and M35 solar-type binaries. Indeed, among the 7 Gyr main-sequence binaries in the model, only those with P {approx}> 1000 days begin to show potentially observable evidence for modifications by dynamical encounters, even after 7 Gyr of evolution within the star cluster. This emphasizes the importance of defining accurate initial conditions for star cluster models, which we propose is best accomplished through comparisons with observations of young open clusters like M35. Furthermore, this finding suggests that observations of the present-day binaries in even old open clusters can provide valuable information on their primordial binary populations. However, despite the model's success at matching the observed solar-type main-sequence population, the model underproduces blue stragglers and produces an overabundance of long-period circular main-sequence-white-dwarf binaries as compared with the true cluster. We explore several potential solutions to the paucity of blue stragglers and conclude that the model dramatically underproduces blue stragglers through mass-transfer processes. We suggest that common-envelope evolution may have been incorrectly imposed on the progenitors of the spurious long-period circular main-sequence-white-dwarf binaries, which perhaps instead should have gone through stable mass transfer to create blue stragglers, thereby bringing both the number and binary frequency of the blue straggler population in the model into agreement with the true blue stragglers in NGC 188. Thus, improvements in the physics of mass transfer and common-envelope evolution employed in the model may in fact solve both discrepancies with the observations. This project highlights the unique accessibility of open clusters to both comprehensive observational surveys and full-scale N-body simulations, both of which have only recently matured sufficiently to enable such a project, and underscores the importance of open clusters to the study of star cluster dynamics.« less
Machine-learned cluster identification in high-dimensional data.
Ultsch, Alfred; Lötsch, Jörn
2017-02-01
High-dimensional biomedical data are frequently clustered to identify subgroup structures pointing at distinct disease subtypes. It is crucial that the used cluster algorithm works correctly. However, by imposing a predefined shape on the clusters, classical algorithms occasionally suggest a cluster structure in homogenously distributed data or assign data points to incorrect clusters. We analyzed whether this can be avoided by using emergent self-organizing feature maps (ESOM). Data sets with different degrees of complexity were submitted to ESOM analysis with large numbers of neurons, using an interactive R-based bioinformatics tool. On top of the trained ESOM the distance structure in the high dimensional feature space was visualized in the form of a so-called U-matrix. Clustering results were compared with those provided by classical common cluster algorithms including single linkage, Ward and k-means. Ward clustering imposed cluster structures on cluster-less "golf ball", "cuboid" and "S-shaped" data sets that contained no structure at all (random data). Ward clustering also imposed structures on permuted real world data sets. By contrast, the ESOM/U-matrix approach correctly found that these data contain no cluster structure. However, ESOM/U-matrix was correct in identifying clusters in biomedical data truly containing subgroups. It was always correct in cluster structure identification in further canonical artificial data. Using intentionally simple data sets, it is shown that popular clustering algorithms typically used for biomedical data sets may fail to cluster data correctly, suggesting that they are also likely to perform erroneously on high dimensional biomedical data. The present analyses emphasized that generally established classical hierarchical clustering algorithms carry a considerable tendency to produce erroneous results. By contrast, unsupervised machine-learned analysis of cluster structures, applied using the ESOM/U-matrix method, is a viable, unbiased method to identify true clusters in the high-dimensional space of complex data. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
The MUSIC of galaxy clusters - II. X-ray global properties and scaling relations
NASA Astrophysics Data System (ADS)
Biffi, V.; Sembolini, F.; De Petris, M.; Valdarnini, R.; Yepes, G.; Gottlöber, S.
2014-03-01
We present the X-ray properties and scaling relations of a large sample of clusters extracted from the Marenostrum MUltidark SImulations of galaxy Clusters (MUSIC) data set. We focus on a sub-sample of 179 clusters at redshift z ˜ 0.11, with 3.2 × 1014 h-1 M⊙ < Mvir < 2 × 1015 h-1 M⊙, complete in mass. We employed the X-ray photon simulator PHOX to obtain synthetic Chandra observations and derive observable-like global properties of the intracluster medium (ICM), as X-ray temperature (TX) and luminosity (LX). TX is found to slightly underestimate the true mass-weighted temperature, although tracing fairly well the cluster total mass. We also study the effects of TX on scaling relations with cluster intrinsic properties: total (M500 and gas Mg,500 mass; integrated Compton parameter (YSZ) of the Sunyaev-Zel'dovich (SZ) thermal effect; YX = Mg,500 TX. We confirm that YX is a very good mass proxy, with a scatter on M500-YX and YSZ-YX lower than 5 per cent. The study of scaling relations among X-ray, intrinsic and SZ properties indicates that simulated MUSIC clusters reasonably resemble the self-similar prediction, especially for correlations involving TX. The observational approach also allows for a more direct comparison with real clusters, from which we find deviations mainly due to the physical description of the ICM, affecting TX and, particularly, LX.
Leishmaniasis Gone Viral: Social Media and an Outbreak of Cutaneous Leishmaniasis.
Mongkolrattanothai, Kanokporn; Nadipuram, Santhosh M; Krakowski, Andrew C; Stone, Margaret M; Krogstad, Paul; Lehman, Deborah
2016-09-01
This report details how social media communication was used in a group of teens to diagnose cutaneous leishmaniasis that they acquired during a trip to Israel. Their posts quickly brought the cluster to the attention of the teens and their parents, leading to prompt recognition of the true etiology of their lesions and appropriate treatment. © 2016 Wiley Periodicals, Inc.
CLUSTER DYNAMICS LARGELY SHAPES PROTOPLANETARY DISK SIZES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vincke, Kirsten; Pfalzner, Susanne, E-mail: kvincke@mpifr-bonn.mpg.de
2016-09-01
To what degree the cluster environment influences the sizes of protoplanetary disks surrounding young stars is still an open question. This is particularly true for the short-lived clusters typical for the solar neighborhood, in which the stellar density and therefore the influence of the cluster environment change considerably over the first 10 Myr. In previous studies, the effect of the gas on the cluster dynamics has often been neglected; this is remedied here. Using the code NBody6++, we study the stellar dynamics in different developmental phases—embedded, expulsion, and expansion—including the gas, and quantify the effect of fly-bys on the diskmore » size. We concentrate on massive clusters (M {sub cl} ≥ 10{sup 3}–6 ∗ 10{sup 4} M {sub Sun}), which are representative for clusters like the Orion Nebula Cluster (ONC) or NGC 6611. We find that not only the stellar density but also the duration of the embedded phase matters. The densest clusters react fastest to the gas expulsion and drop quickly in density, here 98% of relevant encounters happen before gas expulsion. By contrast, disks in sparser clusters are initially less affected, but because these clusters expand more slowly, 13% of disks are truncated after gas expulsion. For ONC-like clusters, we find that disks larger than 500 au are usually affected by the environment, which corresponds to the observation that 200 au-sized disks are common. For NGC 6611-like clusters, disk sizes are cut-down on average to roughly 100 au. A testable hypothesis would be that the disks in the center of NGC 6611 should be on average ≈20 au and therefore considerably smaller than those in the ONC.« less
Szluha, Kornélia; Lazányi, Kornélia; Horváth, Akos; Szántó, János; Tóth, Judit; Hernádi, Zoltán; Póka, Róbert; Damjanovich, László; Garami, Zoltán; Fülöp, Balázs; Molnár, Péter
2008-03-01
In the course of their everyday work health care professionals (HCPs) often have to change their true feelings. The literature labels this performance as emotional labor. This article is presenting data on the characteristics of HCPs' most endangered by the negative consequences of emotional labor. Our simple choice question survey was conducted at Debrecen University Medical Healthcare Center with the help of 50 oncology HCPs volunteers. Nearly 90% of the HCPs examined change their true feelings in the course of work. It is very difficult to classify those threatened by the negative upshot of this emotional labor. Due to our research we found appalling differences of work motivation that were tightly interconnected with the respondents' emotional labor and their perceived role/emotional expectations. We succeeded in establishing three clusters and defining each cluster's characteristics. Figures suggest that only somewhat more than the half of the HCPs is authentic professional helper, and 45% of them does not or only slightly perceive the patients' demands concerning their work. Therefore, it is important that the work environment does not only assist the work of HCPs by professional means, but along emotional dimensions as well.
NASA Technical Reports Server (NTRS)
Jaffe, Walter; Ford, Holland C.; O'Connell, Robert W.; Bosch, Frank C. Van Den; Ferrarese, Laura
1994-01-01
Using the Hubble Space Telescope we have observed at 10 pc resolution the nuclei of a luminosity-limited sample of 14 E and E/SO galaxies in the Virgo Cluster with magnitudes B(sub T) = 9.4 to 13.4. In this paper we present the images, and discuss the results of the detailed analysis of the surface photometry given in two companion papers. We find that the nuclear and near-nuclear morphologies confirm and strengthen the previously recognized dichotomy of 'E' galaxies into 'true' and 'disky' subtypes. The latter, usually classified E4 or later, often show a bright nuclear disk of radius approximately 100 pc. Essentially all early-type galaxies with -18 greater than M(sub B) greater than -20 are disky. Most true E galaxies are classified E4 or earlier. Most galaxies of both types show dust in the nuclear regions, the most remarkable example being a compact dust disk in NGC 4261. Other than dust, no anomalies were detected in the centers of the three galaxies in our sample which show clear kinematic evidence for a decoupled component.
NASA Astrophysics Data System (ADS)
Ulbrich, Sven; Pinto, Joaquim G.; Economou, Theodoros; Stephenson, David B.; Karremann, Melanie K.; Shaffrey, Len C.
2017-04-01
Cyclone families are a frequent synoptic weather feature in the Euro-Atlantic area, particularly during wintertime. Given appropriate large-scale conditions, such series (clusters) of storms may cause large socio-economic impacts and cumulative losses. Recent studies analyzing reanalysis data using single cyclone tracking methods have shown that serial clustering of cyclones occurs on both flanks and downstream regions of the North Atlantic storm track. Based on winter (DJF) cyclone counts from the IMILAST cyclone database, we explore the representation of serial clustering in the ERA-Interim period and its relationship with the NAO-phase and jet intensity. With this aim, clustering is estimated by the dispersion of winter (DJF) cyclone passages for each grid point over the Euro-Atlantic area. Results indicate that clustering over the Eastern North Atlantic and Western Europe can be identified for all methods, although the exact location and the dispersion magnitude may vary. The relationship between clustering and (i) the NAO-phase and (ii) jet intensity over the North Atlantic is statistically evaluated. Results show that the NAO-index and the jet intensity show a strong contribution to clustering, even though some spread is found between methods. We conclude that the general features of clustering of extratropical cyclones over the North Atlantic and Western Europe are robust to the choice of tracking method. The same is true for the influence of the NAO and jet intensity on cyclone dispersion.
NASA Astrophysics Data System (ADS)
Shvartsburg, Alexandre A.; Siu, K. W. Michael
2001-06-01
Modeling the delayed dissociation of clusters had been over the last decade a frontline development area in chemical physics. It is of fundamental interest how statistical kinetics methods previously validated for regular molecules and atomic nuclei may apply to clusters, as this would help to understand the transferability of statistical models for disintegration of complex systems across various classes of physical objects. From a practical perspective, accurate simulation of unimolecular decomposition is critical for the extraction of true thermochemical values from measurements on the decay of energized clusters. Metal clusters are particularly challenging because of the multitude of low-lying electronic states that are coupled to vibrations. This has previously been accounted for assuming the average electronic structure of a conducting cluster approximated by the levels of electron in a cavity. While this provides a reasonable time-averaged description, it ignores the distribution of instantaneous electronic structures in a "boiling" cluster around that average. Here we set up a new treatment that incorporates the statistical distribution of electronic levels around the average picture using random matrix theory. This approach faithfully reflects the completely chaotic "vibronic soup" nature of hot metal clusters. We found that the consideration of electronic level statistics significantly promotes electronic excitation and thus increases the magnitude of its effect. As this excitation always depresses the decay rates, the inclusion of level statistics results in slower dissociation of metal clusters.
Density-Aware Clustering Based on Aggregated Heat Kernel and Its Transformation
Huang, Hao; Yoo, Shinjae; Yu, Dantong; ...
2015-06-01
Current spectral clustering algorithms suffer from the sensitivity to existing noise, and parameter scaling, and may not be aware of different density distributions across clusters. If these problems are left untreated, the consequent clustering results cannot accurately represent true data patterns, in particular, for complex real world datasets with heterogeneous densities. This paper aims to solve these problems by proposing a diffusion-based Aggregated Heat Kernel (AHK) to improve the clustering stability, and a Local Density Affinity Transformation (LDAT) to correct the bias originating from different cluster densities. AHK statistically\\ models the heat diffusion traces along the entire time scale, somore » it ensures robustness during clustering process, while LDAT probabilistically reveals local density of each instance and suppresses the local density bias in the affinity matrix. Our proposed framework integrates these two techniques systematically. As a result, not only does it provide an advanced noise-resisting and density-aware spectral mapping to the original dataset, but also demonstrates the stability during the processing of tuning the scaling parameter (which usually controls the range of neighborhood). Furthermore, our framework works well with the majority of similarity kernels, which ensures its applicability to many types of data and problem domains. The systematic experiments on different applications show that our proposed algorithms outperform state-of-the-art clustering algorithms for the data with heterogeneous density distributions, and achieve robust clustering performance with respect to tuning the scaling parameter and handling various levels and types of noise.« less
Dual-energy in mammography: feasibility study
NASA Astrophysics Data System (ADS)
Jafroudi, Hamid; Lo, Shih-Chung B.; Li, Huai; Steller Artz, Dorothy E.; Freedman, Matthew T.; Mun, Seong K.
1996-04-01
The purpose of this work is to examine the feasibility of dual-energy techniques to enhance the detection of microcalcifications in digital mammography. The digital mammography system used in this study consists of two different mammography systems; one is the conventional mammography system with molybdenum target and Mo filtration and the other is the clinical version of a low dose x-ray system with tungsten target and aluminum filtration. The low dose system is optimized for screen-film mammography with a highly efficient scatter rejection device built by Fischer Imaging Systems for evaluation at NIH. The system was designed by the University of Southern California based on multiparameter optimization techniques. Prototypes of this system have been constructed and evaluated at the Center for Devices and Radiological Health. The digital radiography system is based on the Fuji 9000 computed radiography (CR) system which uses a storage phosphor imaging plate as the receptor. High resolution plates (HR-V) are used in this study. Dual-energy is one technique to reduce the structured noise associated with the complexity of the background of normal anatomy surrounding a lesion. This can be done by taking the advantage of the x-ray attenuation characteristics of two different structures such as soft tissue and bone in chest radiography. We have applied this technique to the detection of microcalcifications in mammography. The overall system performance based on this technique is evaluated. Results presented are based on the evaluation of phantom images.
NASA Astrophysics Data System (ADS)
Cho, Baek Hwan; Chang, Chuho; Lee, Jong-Ha; Ko, Eun Young; Seong, Yeong Kyeong; Woo, Kyoung-Gu
2013-02-01
The existence of microcalcifications (MCs) is an important marker of malignancy in breast cancer. In spite of the benefits in mass detection for dense breasts, ultrasonography is believed that it might not reliably detect MCs. For computer aided diagnosis systems, however, accurate detection of MCs has the possibility of improving the performance in both Breast Imaging-Reporting and Data System (BI-RADS) lexicon description for calcifications and malignancy classification. We propose a new efficient and effective method for MC detection using image enhancement and threshold adjacency statistics (TAS). The main idea of TAS is to threshold an image and to count the number of white pixels with a given number of adjacent white pixels. Our contribution is to adopt TAS features and apply image enhancement to facilitate MC detection in ultrasound images. We employed fuzzy logic, tophat filter, and texture filter to enhance images for MCs. Using a total of 591 images, the classification accuracy of the proposed method in MC detection showed 82.75%, which is comparable to that of Haralick texture features (81.38%). When combined, the performance was as high as 85.11%. In addition, our method also showed the ability in mass classification when combined with existing features. In conclusion, the proposed method exploiting image enhancement and TAS features has the potential to deal with MC detection in ultrasound images efficiently and extend to the real-time localization and visualization of MCs.
Mustafi, Devkumar; Fan, Xiaobing; Peng, Bo; Foxley, Sean; Palgen, Jeremy; Newstead, Gillian M.
2015-01-01
Calcium oxalate (CaOX) crystals and calcium hydroxyapatite (CaHA) crystals were commonly associated with breast benign and malignant lesions, respectively. In this research, CaOX (n = 6) and CaHA (n = 6) crystals in air-bubble-free agarose phantom were studied and characterized by using MRI at 9.4 Tesla scanner. Calcium micro-crystals sizes ranged from 200 – 500 microns were made with either 99% pure CaOX or CaHA powder and embedded in agar to mimic the dimensions and calcium content of breast microcalcifications in vivo. MRI data were acquired with high spatial resolution T2-weighted (T2W) images and gradient echo images with five different echo times (TEs). The crystals areas were determined by setting the threshold relative to agarose signal. The ratio of crystals areas were calculated by the measurements from gradient echo images divided by T2W images. Then the ratios as a function of TE were fitted with the radical function. The results showed that the blooming artifacts due to magnetic susceptibility between agar and CaHA crystals were more than twice as large as the susceptibility in CaOX crystals (p < 0.05). In addition, larger bright rings were observed on gradient echo images around CaHA crystals compared to CaOX crystals. Our results suggest that MRI may provide useful information regarding breast microcalcifications by evaluating the apparent area of crystals ratios obtained between gradient echo and T2W images. PMID:26392170
Mordang, Jan-Jurre; Gubern-Mérida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico
2017-04-01
Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated by microcalcification detection algorithms. We aim at reducing the number of obvious false-positive findings by adding an additional step in the detection method. In this step, a multiclass machine learning method is implemented in which dedicated classifiers learn to recognize the patterns of obvious false-positive subtypes that occur most frequently. The method is compared to a conventional two-class approach, where all false-positive subtypes are grouped together in one class, and to the baseline CADe system without the new false-positive removal step. The methods are evaluated on an independent dataset containing 1,542 screening examinations of which 80 examinations contain malignant microcalcifications. Analysis showed that the multiclass approach yielded a significantly higher sensitivity compared to the other two methods (P < 0.0002). At one obvious false positive per 100 images, the baseline CADe system detected 61% of the malignant examinations, while the systems with the two-class and multiclass false-positive reduction step detected 73% and 83%, respectively. Our study showed that by adding the proposed method to a CADe system, the number of obvious false positives can decrease significantly (P < 0.0002). © 2017 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
de Oliveira, Helder C. R.; Moraes, Diego R.; Reche, Gustavo A.; Borges, Lucas R.; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.
2017-03-01
This paper presents a new local micro-pattern texture descriptor for the detection of Architectural Distortion (AD) in digital mammography images. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automatic detection of AD, but their performance are still unsatisfactory. The proposed descriptor, Local Mapped Pattern (LMP), is a generalization of the Local Binary Pattern (LBP), which is considered one of the most powerful feature descriptor for texture classification in digital images. Compared to LBP, the LMP descriptor captures more effectively the minor differences between the local image pixels. Moreover, LMP is a parametric model which can be optimized for the desired application. In our work, the LMP performance was compared to the LBP and four Haralick's texture descriptors for the classification of 400 regions of interest (ROIs) extracted from clinical mammograms. ROIs were selected and divided into four classes: AD, normal tissue, microcalcifications and masses. Feature vectors were used as input to a multilayer perceptron neural network, with a single hidden layer. Results showed that LMP is a good descriptor to distinguish AD from other anomalies in digital mammography. LMP performance was slightly better than the LBP and comparable to Haralick's descriptors (mean classification accuracy = 83%).
Perez-Ponce, Hector; Daul, Christian; Wolf, Didier; Noel, Alain
2013-08-01
In mammography, image quality assessment has to be directly related to breast cancer indicator (e.g. microcalcifications) detectability. Recently, we proposed an X-ray source/digital detector (XRS/DD) model leading to such an assessment. This model simulates very realistic contrast-detail phantom (CDMAM) images leading to gold disc (representing microcalcifications) detectability thresholds that are very close to those of real images taken under the simulated acquisition conditions. The detection step was performed with a mathematical observer. The aim of this contribution is to include human observers into the disc detection process in real and virtual images to validate the simulation framework based on the XRS/DD model. Mathematical criteria (contrast-detail curves, image quality factor, etc.) are used to assess and to compare, from the statistical point of view, the cancer indicator detectability in real and virtual images. The quantitative results given in this paper show that the images simulated by the XRS/DD model are useful for image quality assessment in the case of all studied exposure conditions using either human or automated scoring. Also, this paper confirms that with the XRS/DD model the image quality assessment can be automated and the whole time of the procedure can be drastically reduced. Compared to standard quality assessment methods, the number of images to be acquired is divided by a factor of eight. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Curl, Robert F.; Smalley, Richard E.
1988-11-01
Experiments involving the laser vaporization of graphite have indicated that one particular cluster of carbon, C60, is preeminently stable; this special stability may be evidence that C60 can readily take the form of a hollow truncated icosahedron (a sort of molecular soccerball). If true, this structure for C60 would be the first example of a spherical aromatic molecule. In fact, because of symmetry properties unique to the number 60, it may be the most perfectly spherical, edgeless molecule possible. Its rapid formation in condensing carbon vapors and its extreme chemical and photophysical stability may have far-reaching implications in a number of areas, particularly combustion science and astrophysics. For these reasons C60 and other clusters of carbon have continued to be the subject of intense research. This article provides a short review of the many new experimental probes of the properties of C60 and related carbon clusters.
TreeCmp: Comparison of Trees in Polynomial Time
Bogdanowicz, Damian; Giaro, Krzysztof; Wróbel, Borys
2012-01-01
When a phylogenetic reconstruction does not result in one tree but in several, tree metrics permit finding out how far the reconstructed trees are from one another. They also permit to assess the accuracy of a reconstruction if a true tree is known. TreeCmp implements eight metrics that can be calculated in polynomial time for arbitrary (not only bifurcating) trees: four for unrooted (Matching Split metric, which we have recently proposed, Robinson-Foulds, Path Difference, Quartet) and four for rooted trees (Matching Cluster, Robinson-Foulds cluster, Nodal Splitted and Triple). TreeCmp is the first implementation of Matching Split/Cluster metrics and the first efficient and convenient implementation of Nodal Splitted. It allows to compare relatively large trees. We provide an example of the application of TreeCmp to compare the accuracy of ten approaches to phylogenetic reconstruction with trees up to 5000 external nodes, using a measure of accuracy based on normalized similarity between trees.
Structure and stability of M6N8 clusters (M = Si, Ge, Sn, Ti).
Davydova, Elena I; Timoshkin, Alexey Y; Frenking, Gernot
2010-06-10
The structures and stabilities of the M(6)N(8) clusters (M = Si, Ge, Sn, Ti) have been theoretically studied at DFT and ab initio levels of theory. Two new isomers have been considered: cage-like molecules and propeller-like molecules. It is shown that only for M = Si are both isomers true minima on the potential energy surface. The thermodynamics of the dissociation process (1/6)M(6)N(8) --> (1/3)M(3)N(4) is discussed. For each M(3)N(4) molecule, four structures with different multiplicity are considered. The thermodynamic analysis shows that independently of the multiplicity of M(3)N(4) nitrides all M(6)N(8) clusters are stable in the gas phase in a wide temperature range and could be potential intermediates in chemical vapor deposition of the nitride materials.
NASA Astrophysics Data System (ADS)
Santra, Biswajit; Michaelides, Angelos; Scheffler, Matthias
2007-11-01
The ability of several density-functional theory (DFT) exchange-correlation functionals to describe hydrogen bonds in small water clusters (dimer to pentamer) in their global minimum energy structures is evaluated with reference to second order Møller-Plesset perturbation theory (MP2). Errors from basis set incompleteness have been minimized in both the MP2 reference data and the DFT calculations, thus enabling a consistent systematic evaluation of the true performance of the tested functionals. Among all the functionals considered, the hybrid X3LYP and PBE0 functionals offer the best performance and among the nonhybrid generalized gradient approximation functionals, mPWLYP and PBE1W perform best. The popular BLYP and B3LYP functionals consistently underbind and PBE and PW91 display rather variable performance with cluster size.
Santra, Biswajit; Michaelides, Angelos; Scheffler, Matthias
2007-11-14
The ability of several density-functional theory (DFT) exchange-correlation functionals to describe hydrogen bonds in small water clusters (dimer to pentamer) in their global minimum energy structures is evaluated with reference to second order Moller-Plesset perturbation theory (MP2). Errors from basis set incompleteness have been minimized in both the MP2 reference data and the DFT calculations, thus enabling a consistent systematic evaluation of the true performance of the tested functionals. Among all the functionals considered, the hybrid X3LYP and PBE0 functionals offer the best performance and among the nonhybrid generalized gradient approximation functionals, mPWLYP and PBE1W perform best. The popular BLYP and B3LYP functionals consistently underbind and PBE and PW91 display rather variable performance with cluster size.
Lekanidi, Katerina; Dilks, Phil; Suaris, Tamara; Kennett, Steffan; Purushothaman, Hema
2017-09-01
The aim of this study was to determine the features that make interval cancers apparent on the preceding screening mammogram and determine whether changes in the ways of performing the interval cancer review will affect the true interval cancer rate. This study was approved by the clinical governance committee. Mammograms of women diagnosed with an interval cancer were included in the study if they had been allocated to either the "suspicious signs" group or "subtle signs" group, during the historic interval cancer review. Three radiologists, individually and blinded to the site of interval cancer, reviewed the mammograms and documented the presence, site, characteristics and classification of any abnormality. Findings were compared with the appearances of the abnormality at the site of subsequent cancer development by a different breast radiologist. The chi-squared test was used in the analysis of the results, seeking associations between recall concordance and cancer mammographic or histological characteristics. 111/590 interval cancers fulfilled the study inclusion criteria. In 17% of the cases none of the readers identified the relevant abnormality on the screening mammogram. 1/3 readers identified the relevant lesion in 22% of the cases, 2/3 readers in 28% of cases and all 3 readers in 33% of cases. The commonest unanimously recalled abnormality was microcalcification and the most challenging mammographic abnormality to detect was asymmetric density. We did not find any statistically significant association between recall concordance and time to interval cancer, position of lesion in the breast, breast density or cancer grade. Even the simple step of performing an independent blinded review of interval cancers reduces the rate of interval cancers classified as missed by up to 39%. Copyright © 2017 Elsevier B.V. All rights reserved.
Chiu, Chia-Yi; Köhn, Hans-Friedrich
2016-09-01
The asymptotic classification theory of cognitive diagnosis (ACTCD) provided the theoretical foundation for using clustering methods that do not rely on a parametric statistical model for assigning examinees to proficiency classes. Like general diagnostic classification models, clustering methods can be useful in situations where the true diagnostic classification model (DCM) underlying the data is unknown and possibly misspecified, or the items of a test conform to a mix of multiple DCMs. Clustering methods can also be an option when fitting advanced and complex DCMs encounters computational difficulties. These can range from the use of excessive CPU times to plain computational infeasibility. However, the propositions of the ACTCD have only been proven for the Deterministic Input Noisy Output "AND" gate (DINA) model and the Deterministic Input Noisy Output "OR" gate (DINO) model. For other DCMs, there does not exist a theoretical justification to use clustering for assigning examinees to proficiency classes. But if clustering is to be used legitimately, then the ACTCD must cover a larger number of DCMs than just the DINA model and the DINO model. Thus, the purpose of this article is to prove the theoretical propositions of the ACTCD for two other important DCMs, the Reduced Reparameterized Unified Model and the General Diagnostic Model.
Morphological estimators on Sunyaev-Zel'dovich maps of MUSIC clusters of galaxies
NASA Astrophysics Data System (ADS)
Cialone, Giammarco; De Petris, Marco; Sembolini, Federico; Yepes, Gustavo; Baldi, Anna Silvia; Rasia, Elena
2018-06-01
The determination of the morphology of galaxy clusters has important repercussions for cosmological and astrophysical studies of them. In this paper, we address the morphological characterization of synthetic maps of the Sunyaev-Zel'dovich (SZ) effect for a sample of 258 massive clusters (Mvir > 5 × 1014 h-1 M⊙ at z = 0), extracted from the MUSIC hydrodynamical simulations. Specifically, we use five known morphological parameters (which are already used in X-ray) and two newly introduced ones, and we combine them in a single parameter. We analyse two sets of simulations obtained with different prescriptions of the gas physics (non-radiative and with cooling, star formation and stellar feedback) at four red shifts between 0.43 and 0.82. For each parameter, we test its stability and efficiency in discriminating the true cluster dynamical state, measured by theoretical indicators. The combined parameter is more efficient at discriminating between relaxed and disturbed clusters. This parameter had a mild correlation with the hydrostatic mass (˜0.3) and a strong correlation (˜0.8) with the offset between the SZ centroid and the cluster centre of mass. The latter quantity is, thus, the most accessible and efficient indicator of the dynamical state for SZ studies.
Vitamin and mineral supplement users. Do they have healthy or unhealthy dietary behaviours?
van der Horst, Klazine; Siegrist, Michael
2011-12-01
It is unknown whether people use vitamin and mineral supplements (VMS) to compensate for unhealthy diets, or people whom already have a healthy diet use VMS. Therefore, this study aimed to examine correlates of VMS use and whether VMS users can be categorised into specific clusters based on dietary lifestyle variables. The data used came from the Swiss Food Panel questionnaire for 2010. The sample consisted of 6189 respondents, mean age was 54 years and 47.6% were males. Data was analysed with logistic regression analysis and hierarchical cluster analysis. The results revealed that for VMS use, gender, age, education, chronic illness, health consciousness, benefits of fortification, convenience food and sugar-sweetened beverage consumption were of importance. Cluster analysis revealed three clusters (1) healthy diet, (2) unhealthy diet and (3) modest diet. Compared to non-users a higher percentage of VMS users was categorised in the healthy cluster and a lower percentage in the unhealthy cluster. More VMS-users were categorised as having an unhealthy diet (31.4%) than having a healthy diet (20.6%). The results suggest that both hypotheses-VMS are used by people with unhealthy diets and by people who least need them-hold true meaning. Copyright © 2011. Published by Elsevier Ltd.
Identifying and Assessing Interesting Subgroups in a Heterogeneous Population
Lee, Woojoo; Alexeyenko, Andrey; Pernemalm, Maria; Guegan, Justine; Dessen, Philippe; Lazar, Vladimir; Lehtiö, Janne; Pawitan, Yudi
2015-01-01
Biological heterogeneity is common in many diseases and it is often the reason for therapeutic failures. Thus, there is great interest in classifying a disease into subtypes that have clinical significance in terms of prognosis or therapy response. One of the most popular methods to uncover unrecognized subtypes is cluster analysis. However, classical clustering methods such as k-means clustering or hierarchical clustering are not guaranteed to produce clinically interesting subtypes. This could be because the main statistical variability—the basis of cluster generation—is dominated by genes not associated with the clinical phenotype of interest. Furthermore, a strong prognostic factor might be relevant for a certain subgroup but not for the whole population; thus an analysis of the whole sample may not reveal this prognostic factor. To address these problems we investigate methods to identify and assess clinically interesting subgroups in a heterogeneous population. The identification step uses a clustering algorithm and to assess significance we use a false discovery rate- (FDR-) based measure. Under the heterogeneity condition the standard FDR estimate is shown to overestimate the true FDR value, but this is remedied by an improved FDR estimation procedure. As illustrations, two real data examples from gene expression studies of lung cancer are provided. PMID:26339613
A Photometric Search for Planets in the Open Cluster NGC 7086
NASA Astrophysics Data System (ADS)
Rosvick, Joanne M.; Robb, Russell
2006-12-01
In an attempt to discover short-period, Jupiter-mass planets orbiting solar-type stars in open clusters, we searched for planetary transits in the populous and relatively unstudied open cluster NGC 7086. A color-magnitude diagram constructed from new B and V photometry is presented, along with revised estimates of the cluster's color excess, distance modulus, and age. Several turnoff stars were observed spectroscopically in order to determine a color excess of E(B-V)=0.83+/-0.02. Empirically fitting the main sequences of two young open clusters and the semiempirical zero-age main sequence of Vandenberg and Poll yielded a distance modulus of (V-MV)=13.4+/-0.3 mag. This corresponds to a true distance modulus of (m-M)0=10.8 mag or a distance of 1.5 kpc to NGC 7086. These values were used with isochrones from the Padova group to obtain a cluster age of 100 Myr. Eleven nights of R-band photometry were used to search for planetary transits. Differential magnitudes were constructed for each star in the cluster. Light curves for each star were produced on a night-to-night basis and inspected for variability. No planetary transits were apparent; however, some interesting variable stars were discovered: a pulsating variable that appears to be a member of the γ Dor class and four possible eclipsing binary stars, one of which actually may be a multiple system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krolewski, Alex G.; Eisenstein, Daniel J., E-mail: akrolewski@college.harvard.edu
2015-04-10
We study the dependence of quasar clustering on quasar luminosity and black hole mass by measuring the angular overdensity of photometrically selected galaxies imaged by the Wide-field Infrared Survey Explorer (WISE) about z ∼ 0.8 quasars from SDSS. By measuring the quasar–galaxy cross-correlation function and using photometrically selected galaxies, we achieve a higher density of tracer objects and a more sensitive detection of clustering than measurements of the quasar autocorrelation function. We test models of quasar formation and evolution by measuring the luminosity dependence of clustering amplitude. We find a significant overdensity of WISE galaxies about z ∼ 0.8 quasarsmore » at 0.2–6.4 h{sup −1} Mpc in projected comoving separation. We find no appreciable increase in clustering amplitude with quasar luminosity across a decade in luminosity, and a power-law fit between luminosity and clustering amplitude gives an exponent of −0.01 ± 0.06 (1 σ error). We also fail to find a significant relationship between clustering amplitude and black hole mass, although our dynamic range in true mass is suppressed due to the large uncertainties in virial black hole mass estimates. Our results indicate that a small range in host dark matter halo mass maps to a large range in quasar luminosity.« less
Boron Nitride-supported Sub-nanometer Pd 6 Clusters for Formic Acid Decomposition: A DFT Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schimmenti, Roberto; Cortese, Remedios; Duca, Dario
A periodic, self-consistent planewave DFT study was carried out to explore the potential use of Pd 6 clusters supported on a boron nitride sheet as a catalyst for the selective decomposition of formic acid (HCOOH) to CO 2 and H 2. The competition between formate (HCOO) and carboxyl (COOH) paths on catalytic sites, with different proximities to the support, was studied. Based on energetics alone, the reaction may mainly follow the HCOO route. Slightly lower activation energies were found at the lateral sites of the cluster as compared to top face sites. This is particularly true for the bidentate tomore » monodentate HCOO conversion. Through comparison of results with similar studies on HCOOH decomposition on extended Pd surfaces, it was demonstrated that the existence of undercoordinated sites in the sub-nanometer cluster could play a key role in preferentially stabilizing HCOO over COOH, which is a common CO precursor in this reaction. A hydrogen spillover mechanism was also investigated; migration toward the boron nitride support is not favorable, at least in the early stages of the reaction. However, hydrogen diffusion on the cluster has low barriers compared to those involved in formic acid decomposition.« less
Boron Nitride-supported Sub-nanometer Pd 6 Clusters for Formic Acid Decomposition: A DFT Study
Schimmenti, Roberto; Cortese, Remedios; Duca, Dario; ...
2017-04-25
A periodic, self-consistent planewave DFT study was carried out to explore the potential use of Pd 6 clusters supported on a boron nitride sheet as a catalyst for the selective decomposition of formic acid (HCOOH) to CO 2 and H 2. The competition between formate (HCOO) and carboxyl (COOH) paths on catalytic sites, with different proximities to the support, was studied. Based on energetics alone, the reaction may mainly follow the HCOO route. Slightly lower activation energies were found at the lateral sites of the cluster as compared to top face sites. This is particularly true for the bidentate tomore » monodentate HCOO conversion. Through comparison of results with similar studies on HCOOH decomposition on extended Pd surfaces, it was demonstrated that the existence of undercoordinated sites in the sub-nanometer cluster could play a key role in preferentially stabilizing HCOO over COOH, which is a common CO precursor in this reaction. A hydrogen spillover mechanism was also investigated; migration toward the boron nitride support is not favorable, at least in the early stages of the reaction. However, hydrogen diffusion on the cluster has low barriers compared to those involved in formic acid decomposition.« less
ERIC Educational Resources Information Center
Feltovich, Paul J.; And Others
This report presents a general framework for studying the acquisition and cognitive representation of biomedical concepts and analyzing the nature and development of misconceptions. The central approach of the report is a selective and highly concentrated analysis of the true nature of clusters of complex concepts and the manner in which they are…
Guenole, Nigel
2018-01-01
The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository.
Guenole, Nigel
2018-01-01
The test for item level cluster bias examines the improvement in model fit that results from freeing an item's between level residual variance from a baseline model with equal within and between level factor loadings and between level residual variances fixed at zero. A potential problem is that this approach may include a misspecified unrestricted model if any non-invariance is present, but the log-likelihood difference test requires that the unrestricted model is correctly specified. A free baseline approach where the unrestricted model includes only the restrictions needed for model identification should lead to better decision accuracy, but no studies have examined this yet. We ran a Monte Carlo study to investigate this issue. When the referent item is unbiased, compared to the free baseline approach, the constrained baseline approach led to similar true positive (power) rates but much higher false positive (Type I error) rates. The free baseline approach should be preferred when the referent indicator is unbiased. When the referent assumption is violated, the false positive rate was unacceptably high for both free and constrained baseline approaches, and the true positive rate was poor regardless of whether the free or constrained baseline approach was used. Neither the free or constrained baseline approach can be recommended when the referent indicator is biased. We recommend paying close attention to ensuring the referent indicator is unbiased in tests of cluster bias. All Mplus input and output files, R, and short Python scripts used to execute this simulation study are uploaded to an open access repository. PMID:29551985
NASA Astrophysics Data System (ADS)
Solorzano, N. N.; Hafner, W.; Jaffe, D.
2005-12-01
We calculated daily kinematic back-trajectories using the NOAA-HYSPLIT model to analyze 7 years of PM2.5 data from National Park sites in the Western U.S. (Glacier N.P., Mount Rainier N.P., Sequoia N.P., Rocky Mountain N.P. and Denali N.P.) The back-trajectories were clustered using a k-means clustering algorithm to segregate the trajectories into 6 main transport patterns. We calculated trajectory clusters for 1, 5 and 10 days to represent short, medium and long-range flow patterns. Some trajectory types and clusters show marked seasonality. Generally faster flow patterns are more prevalent in winter and slower/stagnant patterns are more prevalent in summer. In addition, we found significant inter-annual variability that may be important for explaining variations in rainfall and/or pollutant concentrations. The 5 and 10-day analyses revealed that, for the 4 non-Alaskan sites, trajectories from Asia tend to be less frequent in the summer, compared to the rest of the year. The clusters of different duration show very different predictive power for rainfall and PM2.5. We found that the 1-day clusters are a better predictor for precipitation and PM2.5 concentrations, as compared to the 5 and 10-day clusters. At each of the sites, there is at least one cluster with an average PM2.5 concentration that is different than the average for the site, indicating distinctive transport patterns. The same is true for 5 and 10-day clusters. Interestingly, only one site, Mount Rainier N.P., shows seasonal differences in PM2.5 concentrations between the clusters that differ from the average.
NASA Astrophysics Data System (ADS)
Mackey, A. D.; Gilmore, G. F.
2003-01-01
We have compiled a pseudo-snapshot data set of two-colour observations from the Hubble Space Telescope archive for a sample of 53 rich LMC clusters with ages of 106-1010 yr. We present surface brightness profiles for the entire sample, and derive structural parameters for each cluster, including core radii, and luminosity and mass estimates. Because we expect the results presented here to form the basis for several further projects, we describe in detail the data reduction and surface brightness profile construction processes, and compare our results with those of previous ground-based studies. The surface brightness profiles show a large amount of detail, including irregularities in the profiles of young clusters (such as bumps, dips and sharp shoulders), and evidence for both double clusters and post-core-collapse (PCC) clusters. In particular, we find power-law profiles in the inner regions of several candidate PCC clusters, with slopes of approximately -0.7, but showing considerable variation. We estimate that 20 +/- 7 per cent of the old cluster population of the Large Magellanic Cloud (LMC) has entered PCC evolution, a similar fraction to that for the Galactic globular cluster system. In addition, we examine the profile of R136 in detail and show that it is probably not a PCC cluster. We also observe a trend in core radius with age that has been discovered and discussed in several previous publications by different authors. Our diagram has better resolution, however, and appears to show a bifurcation at several hundred Myr. We argue that this observed relationship reflects true physical evolution in LMC clusters, with some experiencing small-scale core expansion owing to mass loss, and others large-scale expansion owing to some unidentified characteristic or physical process.
Galaxy Kinematics and Mass Calibration in Massive SZE Selected Galaxy Clusters to z=1.3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Capasso, R.; et al.
The galaxy phase-space distribution in galaxy clusters provides insights into the formation and evolution of cluster galaxies, and it can also be used to measure cluster mass profiles. We present a dynamical study based onmore » $$\\sim$$3000 passive, non-emission line cluster galaxies drawn from 110 galaxy clusters. The galaxy clusters were selected using the Sunyaev-Zel'dovich effect (SZE) in the 2500 deg$^2$ SPT-SZ survey and cover the redshift range $0.2 < z < 1.3$. We model the clusters using the Jeans equation, while adopting NFW mass profiles and a broad range of velocity dispersion anisotropy profiles. The data prefer velocity dispersion anisotropy profiles that are approximately isotropic near the center and increasingly radial toward the cluster virial radius, and this is true for all redshifts and masses we study. The pseudo-phase-space density profile of the passive galaxies is consistent with expectations for dark matter particles and subhalos from cosmological $N$-body simulations. The dynamical mass constraints are in good agreement with external mass estimates of the SPT cluster sample from either weak lensing, velocity dispersions, or X-ray $$Y_X$$ measurements. However, the dynamical masses are lower (at the 2.2$$\\sigma$$ level) when compared to the mass calibration favored when fitting the SPT cluster data to a LCDM model with external cosmological priors, including CMB anisotropy data from Planck. The tension grows with redshift, where in the highest redshift bin the ratio of dynamical to SPT+Planck masses is $$\\eta=0.63^{+0.13}_{-0.08}\\pm0.05$$ (statistical and systematic), corresponding to 2.6$$\\sigma$$ tension.« less
Brice, Matthew E; Gossweiler, Marisa; Bennett, Larry
2017-03-01
Artifacts are universal across all imaging modalities, varying in their conspicuity and significance. In this report three patients with pathology-proven breast cancer who had densities masquerading as microcalcifications at the resection margins of the lumpectomy specimens, but had negative microscopic margins, will be discussed. It was determined that these pseudocalcifications were the result of ink precipitates from a commonly utilized tissue marking dye. This artifact was further evaluated and reproduced by utilizing a boneless chicken breast as a phantom. © RSNA, 2016.
Flat epithelial atypia of the breast.
Nasser, Selim M
2009-01-01
"Flat epithelial atypia" is the adopted term by the WHO working group on breast tumor referring to an early neoplastic breast lesion affecting the terminal duct-lobular units. Pathologists have described this lesion under a variety of names including columnar cell lesions and low-grade clinging carcinoma in situ. It is usually encountered on breast biopsies performed for mammographically-identified microcalcifications. Because of its relatively frequent association with carcinomas, its recognition in biopsy specimens is important. This review will focus on the histopathologic features, differential diagnosis, biologic potential, clinical significance and management of this lesion.
Congenital Zika Virus Infection Induces Severe Spinal Cord Injury.
Ramalho, Fernando S; Yamamoto, Aparecida Y; da Silva, Luis L; Figueiredo, Luiz T M; Rocha, Lenaldo B; Neder, Luciano; Teixeira, Sara R; Apolinário, Letícia A; Ramalho, Leandra N Z; Silva, Deisy M; Coutinho, Conrado M; Melli, Patrícia P; Augusto, Marlei J; Santoro, Ligia B; Duarte, Geraldo; Mussi-Pinhata, Marisa M
2017-08-15
We report 2 fatal cases of congenital Zika virus (ZIKV) infection. Brain anomalies, including atrophy of the cerebral cortex and brainstem, and cerebellar aplasia were observed. The spinal cord showed architectural distortion, severe neuronal loss, and microcalcifications. The ZIKV proteins and flavivirus-like particles were detected in cytoplasm of spinal neurons, and spinal cord samples were positive for ZIKV RNA. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Groenewold, Matthew R
2006-01-01
Local health departments are among the first agencies to respond to disasters or other mass emergencies. However, they often lack the ability to handle large-scale events. Plans including locally developed and deployed tools may enhance local response. Simplified cluster sampling methods can be useful in assessing community needs after a sudden-onset, short duration event. Using an adaptation of the methodology used by the World Health Organization Expanded Programme on Immunization (EPI), a Microsoft Access-based application for two-stage cluster sampling of residential addresses in Louisville/Jefferson County Metro, Kentucky was developed. The sampling frame was derived from geographically referenced data on residential addresses and political districts available through the Louisville/Jefferson County Information Consortium (LOJIC). The program randomly selected 30 clusters, defined as election precincts, from within the area of interest, and then, randomly selected 10 residential addresses from each cluster. The program, called the Rapid Assessment Tools Package (RATP), was tested in terms of accuracy and precision using data on a dichotomous characteristic of residential addresses available from the local tax assessor database. A series of 30 samples were produced and analyzed with respect to their precision and accuracy in estimating the prevalence of the study attribute. Point estimates with 95% confidence intervals were calculated by determining the proportion of the study attribute values in each of the samples and compared with the population proportion. To estimate the design effect, corresponding simple random samples of 300 addresses were taken after each of the 30 cluster samples. The sample proportion fell within +/-10 absolute percentage points of the true proportion in 80% of the samples. In 93.3% of the samples, the point estimate fell within +/-12.5%, and 96.7% fell within +/-15%. All of the point estimates fell within +/-20% of the true proportion. Estimates of the design effect ranged from 0.926 to 1.436 (mean = 1.157, median = 1.170) for the 30 samples. Although prospective evaluation of its performance in field trials or a real emergency is required to confirm its utility, this study suggests that the RATP, a locally designed and deployed tool, may provide population-based estimates of community needs or the extent of event-related consequences that are precise enough to serve as the basis for the initial post-event decisions regarding relief efforts.
Climbing the Ladder of Star Formation Feedback
NASA Astrophysics Data System (ADS)
Frank, Adam
2012-10-01
While much is understood about isolated star formation, the opposite is true for star formation in clusters of both low and high mass. In particular the mechanisms by which many coevally formed stars affect their parent cloud environment remains poorly characterized. Fundamental questions such as interplay between multiple outflows, ionization fronts and turbulence are just beginning to be fully articulated. Distinguishing between the nature of feedback in clusters of different mass is also critical. In high mass clusters O stars are expected to dominate energetics while in low mass clusters multiple collimated outflows may represent the dominant feedback mechanism. Thus the issue of feedback modalities in clusters of different masses represents one of the major challenges to the next generation of star formation studies. In this proposal we seek to carry forward a focused theoretical study of feedback in both low and high-mass cluster environments with direct connections to observations. Using a state-of-the-art Adaptive Mesh Refinement MHD multi-physics code {developed by our group} we propose two computational studies: {1} multiple, interacting outflows and their role in altering the properties of a parent low mass cluster {2} Poorly collimated outburst/outflows from massive star{s} and their effect on high mass cluster star forming environments. In both cases we will use initial conditions derived from high-resolution AMR MHD simulations of cloud/cluster formation. Synthetic observations derived from the simulations {in a variety of emission lines from ions to atoms to molecules} will allow for direct contact with HST and other star formation databases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berman, Benjamin P.; Pfeiffer, Barret D.; Laverty, Todd R.
2004-08-06
The identification of sequences that control transcription in metazoans is a major goal of genome analysis. In a previous study, we demonstrated that searching for clusters of predicted transcription factor binding sites could discover active regulatory sequences, and identified 37 regions of the Drosophila melanogaster genome with high densities of predicted binding sites for five transcription factors involved in anterior-posterior embryonic patterning. Nine of these clusters overlapped known enhancers. Here, we report the results of in vivo functional analysis of 27 remaining clusters. We generated transgenic flies carrying each cluster attached to a basal promoter and reporter gene, and assayedmore » embryos for reporter gene expression. Six clusters are enhancers of adjacent genes: giant, fushi tarazu, odd-skipped, nubbin, squeeze and pdm2; three drive expression in patterns unrelated to those of neighboring genes; the remaining 18 do not appear to have enhancer activity. We used the Drosophila pseudoobscura genome to compare patterns of evolution in and around the 15 positive and 18 false-positive predictions. Although conservation of primary sequence cannot distinguish true from false positives, conservation of binding-site clustering accurately discriminates functional binding-site clusters from those with no function. We incorporated conservation of binding-site clustering into a new genome-wide enhancer screen, and predict several hundred new regulatory sequences, including 85 adjacent to genes with embryonic patterns. Measuring conservation of sequence features closely linked to function--such as binding-site clustering--makes better use of comparative sequence data than commonly used methods that examine only sequence identity.« less
Measuring Spatial Dependence for Infectious Disease Epidemiology
Grabowski, M. Kate; Cummings, Derek A. T.
2016-01-01
Global spatial clustering is the tendency of points, here cases of infectious disease, to occur closer together than expected by chance. The extent of global clustering can provide a window into the spatial scale of disease transmission, thereby providing insights into the mechanism of spread, and informing optimal surveillance and control. Here the authors present an interpretable measure of spatial clustering, τ, which can be understood as a measure of relative risk. When biological or temporal information can be used to identify sets of potentially linked and likely unlinked cases, this measure can be estimated without knowledge of the underlying population distribution. The greater our ability to distinguish closely related (i.e., separated by few generations of transmission) from more distantly related cases, the more closely τ will track the true scale of transmission. The authors illustrate this approach using examples from the analyses of HIV, dengue and measles, and provide an R package implementing the methods described. The statistic presented, and measures of global clustering in general, can be powerful tools for analysis of spatially resolved data on infectious diseases. PMID:27196422
Robust fiber clustering of cerebral fiber bundles in white matter
NASA Astrophysics Data System (ADS)
Yao, Xufeng; Wang, Yongxiong; Zhuang, Songlin
2014-11-01
Diffusion tensor imaging fiber tracking (DTI-FT) has been widely accepted in the diagnosis and treatment of brain diseases. During the rendering pipeline of specific fiber tracts, the image noise and low resolution of DTI would lead to false propagations. In this paper, we propose a robust fiber clustering (FC) approach to diminish false fibers from one fiber tract. Our algorithm consists of three steps. Firstly, the optimized fiber assignment continuous tracking (FACT) is implemented to reconstruct one fiber tract; and then each curved fiber in the fiber tract is mapped to a point by kernel principal component analysis (KPCA); finally, the point clouds of fiber tract are clustered by hierarchical clustering which could distinguish false fibers from true fibers in one tract. In our experiment, the corticospinal tract (CST) in one case of human data in vivo was used to validate our method. Our method showed reliable capability in decreasing the false fibers in one tract. In conclusion, our method could effectively optimize the visualization of fiber bundles and would help a lot in the field of fiber evaluation.
Phase stabilisation of hexagonal barium titanate doped with transition metals: A computational study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dawson, J.A., E-mail: mtp09jd@sheffield.ac.uk; Freeman, C.L.; Harding, J.H.
Interatomic potentials recently developed for the modelling of BaTiO{sub 3} have been used to explore the stabilisation of the hexagonal polymorph of BaTiO{sub 3} by doping with transition metals (namely Mn, Co, Fe and Ni) at the Ti-site. Classical simulations have been completed on both the cubic and hexagonal polymorphs to investigate the energetic consequences of transition metal doping on each polymorph. Ti-site charge compensation mechanisms have been used for the multi-valent transition metal ions and cluster binding energies have been considered. Simulations show a significant energetic gain when doping occurs at Ti sites in the face sharing dimers (Ti{submore » 2} sites) of the hexagonal polymorph compared with the doping of the cubic polymorph. This energetic difference between the two polymorphs is true for all transition metals tested and all charge states and in the case of tri- and tetra-valent dopants negative solution energies are found for the hexagonal polymorph suggesting actual polymorph stabilisation occurs with the incorporation of these ions as observed experimentally. Oxidation during incorporation of Ni{sup 2+} and Fe{sup 3+} ions has also been considered. - Graphical abstract: The representation of the strongest binding energy clusters for tri-valent dopants—(a) Ti{sub 2}/O{sub 1} cluster and (b) Ti{sub 2}/O{sub 2} cluster. Highlights: ► Classical simulations show a significant energetic gain when doping occurs at Ti sites in the face sharing dimers (Ti2 sites) of the hexagonal polymorph compared with the doping of the cubic polymorph. ► This energetic difference between the two polymorphs is true for all transition metals tested and all charge states. ► In the case of tri- and tetra- valent dopants negative solution energies are found for the hexagonal polymorph suggesting actual polymorph stabilisation occurs with the incorporation of these ions.« less
Classification and unsupervised clustering of LIGO data with Deep Transfer Learning
NASA Astrophysics Data System (ADS)
George, Daniel; Shen, Hongyu; Huerta, E. A.
2018-05-01
Gravitational wave detection requires a detailed understanding of the response of the LIGO and Virgo detectors to true signals in the presence of environmental and instrumental noise. Of particular interest is the study of anomalous non-Gaussian transients, such as glitches, since their occurrence rate in LIGO and Virgo data can obscure or even mimic true gravitational wave signals. Therefore, successfully identifying and excising these anomalies from gravitational wave data is of utmost importance for the detection and characterization of true signals and for the accurate computation of their significance. To facilitate this work, we present the first application of deep learning combined with transfer learning to show that knowledge from pretrained models for real-world object recognition can be transferred for classifying spectrograms of glitches. To showcase this new method, we use a data set of twenty-two classes of glitches, curated and labeled by the Gravity Spy project using data collected during LIGO's first discovery campaign. We demonstrate that our Deep Transfer Learning method enables an optimal use of very deep convolutional neural networks for glitch classification given small and unbalanced training data sets, significantly reduces the training time, and achieves state-of-the-art accuracy above 98.8%, lowering the previous error rate by over 60%. More importantly, once trained via transfer learning on the known classes, we show that our neural networks can be truncated and used as feature extractors for unsupervised clustering to automatically group together new unknown classes of glitches and anomalous signals. This novel capability is of paramount importance to identify and remove new types of glitches which will occur as the LIGO/Virgo detectors gradually attain design sensitivity.
The structure of clusters of galaxies
NASA Astrophysics Data System (ADS)
Fox, David Charles
When infalling gas is accreted onto a cluster of galaxies, its kinetic energy is converted to thermal energy in a shock, heating the ions. Using a self-similar spherical model, we calculate the collisional heating of the electrons by the ions, and predict the electron and ion temperature profiles. While there are significant differences between the two, they occur at radii larger than currently observable, and too large to explain observed X-ray temperature declines in clusters. Numerical simulations by Navarro, Frenk, & White (1996) predict a universal dark matter density profile. We calculate the expected number of multiply-imaged background galaxies in the Hubble Deep Field due to foreground groups and clusters with this profile. Such groups are up to 1000 times less efficient at lensing than the standard singular isothermal spheres. However, with either profile, the expected number of galaxies lensed by groups in the Hubble Deep Field is at most one, consistent with the lack of clearly identified group lenses. X-ray and Sunyaev-Zel'dovich (SZ) effect observations can be combined to determine the distance to clusters of galaxies, provided the clusters are spherical. When applied to an aspherical cluster, this method gives an incorrect distance. We demonstrate a method for inferring the three-dimensional shape of a cluster and its correct distance from X-ray, SZ effect, and weak gravitational lensing observations, under the assumption of hydrostatic equilibrium. We apply this method to simple, analytic models of clusters, and to a numerically simulated cluster. Using artificial observations based on current X-ray and SZ effect instruments, we recover the true distance without detectable bias and with uncertainties of 4 percent.
Ouldamer, Lobna; Poisson, Elodie; Arbion, Flavie; Bonneau, Carole; Vildé, Anne; Body, Gilles; Michenet, Patrick
2018-04-14
The purposes of this study were to evaluate the outcome of women with pure flat atypical atypia (FEA) diagnosed at vacuum-assisted breast biopsy (VABB) targeting microcalcifications and to determine whether clinical, radiological and pathologic parameters are able to predict which lesions will be upgraded to malignancy. 2414 cases of consecutive VABB for microcalcifications using VA 8-, 10- or 11-Gauge stereotactically guided core biopsy performed between January 2005 and December 2011 from two french breast cancer centers were evaluated. Data of women with VABB-diagnosed pure FEA who underwent either excisional surgery or mammographic follow-up were analyzed. Cases with mass lesions or ipsilateral cancers were excluded. Two pathologists (FA,PM) reviewed the results of procedures performed. Clinical, radiological, as well as histological criteria have been studied in order to determine the correlation between these factors and carcinoma underestimation. This study included 70 cases of pure FEA. Twenty women underwent surgical excision and 50 had clinical and mammographic surveillance only. In three women FEA was upgraded to breast cancer on excision. Clinical and mammographic follow-up for a mean of 56 months ± 27 in the group without excision showed two cancers in the same breast (Intermediate grade DCIS, and invasive ductal carcinoma 84 and 48 months respectively after VABB). Three factors were significantly predictive of underestimation or occurence of cancer for pure FEA when the radiologic lesions are calcifications: age≥ 57 years, radiologic size >10 mm and number of FEA foci ≥4. Copyright © 2018. Published by Elsevier Ltd.
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung
2017-01-01
Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656
Use of contrast-enhanced spectral mammography for intramammary cancer staging: preliminary results.
Blum, Katrin S; Rubbert, Christian; Mathys, Britta; Antoch, Gerald; Mohrmann, Svjetlana; Obenauer, Silvia
2014-11-01
To prospectively evaluate and compare the accuracy of contrast-enhanced spectral mammography (CESM) and ultrasound (US) in size measurement of breast cancer with histologic tumor sizes as gold standard. Twenty women aged between 40-73 years (mean age, 57 ± 10 years) with histologically proven invasive ductal/lobular carcinomas were included in the study. Agreement between imaging tumor size (CESM and US) and histopathologic tumor size was evaluated with Bland-Altman analysis. Stereotactically guided vacuum biopsy was performed in four patients after CESM. Two independent reviewers described artifacts of CESM. Motion artifacts did not occur in the study. CESM-specific artifacts caused by scattered radiation mostly occurred in oblique view of CESM. Background enhancement of breast tissue was seen in four patients. Mean difference of tumor sizes was 0.3 mm (6.34%) between CESM and histology and -2.2 mm (-7.59%) between US and histology. Limits of agreement ranged from -18.9 to 19.48 mm for CESM and from -17.1 to 12.7 mm with US. Especially smaller tumors with a size <23 mm were measured more precisely with CESM. Enhancement of breast tissue around microcalcifications correlated with abnormalities. CESM is accurate in size measurements of small breast tumors. On average CESM leads to a slight overestimation of tumor size, whereas US tends to underestimate tumor size. Assessment of the breast tissue can be limited by the scattered radiation artifact and background enhancement of breast tissue. CESM seems to be helpful in the characterization of breast tissue around microcalcifications. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shi, Bibo; Grimm, Lars J.; Mazurowski, Maciej A.; Marks, Jeffrey R.; King, Lorraine M.; Maley, Carlo C.; Hwang, E. Shelley; Lo, Joseph Y.
2017-03-01
Predicting the risk of occult invasive disease in ductal carcinoma in situ (DCIS) is an important task to help address the overdiagnosis and overtreatment problems associated with breast cancer. In this work, we investigated the feasibility of using computer-extracted mammographic features to predict occult invasive disease in patients with biopsy proven DCIS. We proposed a computer-vision algorithm based approach to extract mammographic features from magnification views of full field digital mammography (FFDM) for patients with DCIS. After an expert breast radiologist provided a region of interest (ROI) mask for the DCIS lesion, the proposed approach is able to segment individual microcalcifications (MCs), detect the boundary of the MC cluster (MCC), and extract 113 mammographic features from MCs and MCC within the ROI. In this study, we extracted mammographic features from 99 patients with DCIS (74 pure DCIS; 25 DCIS plus invasive disease). The predictive power of the mammographic features was demonstrated through binary classifications between pure DCIS and DCIS with invasive disease using linear discriminant analysis (LDA). Before classification, the minimum redundancy Maximum Relevance (mRMR) feature selection method was first applied to choose subsets of useful features. The generalization performance was assessed using Leave-One-Out Cross-Validation and Receiver Operating Characteristic (ROC) curve analysis. Using the computer-extracted mammographic features, the proposed model was able to distinguish DCIS with invasive disease from pure DCIS, with an average classification performance of AUC = 0.61 +/- 0.05. Overall, the proposed computer-extracted mammographic features are promising for predicting occult invasive disease in DCIS.
Hallucinogens and cannabinoids for headache.
McGeeney, Brian E
2012-10-01
Most hallucinogens and cannabinoids fall into Federal Controlled Substances schedule 1, meaning they cannot be prescribed by practitioners, allegedly have no accepted medical use, and have a high abuse potential. The legal and regulatory status has inhibited clinical research on these substances such that there are no blinded studies from which to assess true efficacy. Despite such classification, hallucinogens and cannabinoids are used by patients with headache on occasion. Cannabinoids in particular have a long history of use for headache and migraine before prohibition and are still used by patients as a migraine abortive. Hallucinogens are being increasing used by cluster headache patients outside of physician recommendation mainly to abort a cluster period and to maintain quiescence for which there is considerable anecdotal success. © 2012 American Headache Society.
The Detection and Statistics of Giant Arcs behind CLASH Clusters
NASA Astrophysics Data System (ADS)
Xu, Bingxiao; Postman, Marc; Meneghetti, Massimo; Seitz, Stella; Zitrin, Adi; Merten, Julian; Maoz, Dani; Frye, Brenda; Umetsu, Keiichi; Zheng, Wei; Bradley, Larry; Vega, Jesus; Koekemoer, Anton
2016-02-01
We developed an algorithm to find and characterize gravitationally lensed galaxies (arcs) to perform a comparison of the observed and simulated arc abundance. Observations are from the Cluster Lensing And Supernova survey with Hubble (CLASH). Simulated CLASH images are created using the MOKA package and also clusters selected from the high-resolution, hydrodynamical simulations, MUSIC, over the same mass and redshift range as the CLASH sample. The algorithm's arc elongation accuracy, completeness, and false positive rate are determined and used to compute an estimate of the true arc abundance. We derive a lensing efficiency of 4 ± 1 arcs (with length ≥6″ and length-to-width ratio ≥7) per cluster for the X-ray-selected CLASH sample, 4 ± 1 arcs per cluster for the MOKA-simulated sample, and 3 ± 1 arcs per cluster for the MUSIC-simulated sample. The observed and simulated arc statistics are in full agreement. We measure the photometric redshifts of all detected arcs and find a median redshift zs = 1.9 with 33% of the detected arcs having zs > 3. We find that the arc abundance does not depend strongly on the source redshift distribution but is sensitive to the mass distribution of the dark matter halos (e.g., the c-M relation). Our results show that consistency between the observed and simulated distributions of lensed arc sizes and axial ratios can be achieved by using cluster-lensing simulations that are carefully matched to the selection criteria used in the observations.
Branching patterns in leaf starches from Arabidopsis mutants deficient in diverse starch synthases.
Zhu, Fan; Bertoft, Eric; Szydlowski, Nicolas; d'Hulst, Christophe; Seetharaman, Koushik
2015-01-12
This is the first report on the cluster structure of transitory starch from Arabidopsis leaves. In addition to wild type, the molecular structures of leaf starch from mutants deficient in starch synthases (SS) including single enzyme mutants ss1-, ss2-, or ss3-, and also double mutants ss1-ss2- and ss1-ss3- were characterized. The mutations resulted in increased amylose content. Clusters from whole starch were isolated by partial hydrolysis using α-amylase of Bacillus amyloliquefaciens. The clusters were then further hydrolyzed with concentrated α-amylase of B. amyloliquefaciens to produce building blocks (α-limit dextrins). Structures of the clusters and their building blocks were characterized by chromatography of samples before and after debranching treatment. While the mutations increased the size of clusters, the reasons were different as reflected by the composition of their unit chains and building blocks. In general, all mutants contained more of a-chains that preferentially increased the number of small building blocks with only two chains. The clusters of the double mutant ss1-ss3- were very large and possessed also more of large building blocks with four or more chains. The results from transitory starch are compared with those from agriculturally important crops in the context that to what extent the Arabidopsis can be a true biotechnological reflection for starch modifications through genetic means. Copyright © 2014 Elsevier Ltd. All rights reserved.
New open cluster candidates discovered in the XSTPS-GAC survey
NASA Astrophysics Data System (ADS)
Guo, Jin-Cheng; Zhang, Hua-Wei; Zhang, Hui-Hua; Liu, Xiao-Wei; Yuan, Hai-Bo; Huang, Yang; Wang, Song; Chen, Li; Zhao, Hai-Bin; Liu, Ji-Feng; Chen, Bing-Qiu; Xiang, Mao-Sheng; Tian, Zhi-Jia; Huo, Zhi-Ying; Wang, Chun
2018-03-01
The Xuyi Schmidt Telescope Photometric Survey of the Galactic Anti-center (XSTPS-GAC) is a photometric sky survey that covers nearly 6000 deg2 towards the Galactic Anti-center (GAC) in the g, r, i bands. Half of its survey field is located on the Galactic Anti-center disk, which makes XSTPS-GAC highly suitable to search for new open clusters in the GAC region. In this paper, we report new open cluster candidates discovered in this survey, as well as properties of these open cluster candidates, such as age, distance and reddening, derived by isochrone fitting in the color-magnitude diagram (CMD). These open cluster candidates are stellar density peaks detected in the star density maps by applying the method from Koposov et al. Each candidate is inspected in terms of its true color image composed from three XSTPS-GAC band images. Then its CMD is checked, in order to identify whether the central region stars have a clear isochrone-like trend differing from background stars. The parameters derived from isochrone fitting for these candidates are mainly based on three band photometry of XSTPS-GAC. Moreover, when these new candidates are able to be seen clearly in 2MASS data, their parameters are also derived based on the 2MASS (J – H, J) CMD. There are a total of 320 known open clusters rediscovered and 24 new open cluster candidates discovered in this work. Furthermore, the parameters of these new candidates, as well as another 11 previously known open clusters, are properly determined for the first time.
Li, Peng; Redden, David T.
2014-01-01
SUMMARY The sandwich estimator in generalized estimating equations (GEE) approach underestimates the true variance in small samples and consequently results in inflated type I error rates in hypothesis testing. This fact limits the application of the GEE in cluster-randomized trials (CRTs) with few clusters. Under various CRT scenarios with correlated binary outcomes, we evaluate the small sample properties of the GEE Wald tests using bias-corrected sandwich estimators. Our results suggest that the GEE Wald z test should be avoided in the analyses of CRTs with few clusters even when bias-corrected sandwich estimators are used. With t-distribution approximation, the Kauermann and Carroll (KC)-correction can keep the test size to nominal levels even when the number of clusters is as low as 10, and is robust to the moderate variation of the cluster sizes. However, in cases with large variations in cluster sizes, the Fay and Graubard (FG)-correction should be used instead. Furthermore, we derive a formula to calculate the power and minimum total number of clusters one needs using the t test and KC-correction for the CRTs with binary outcomes. The power levels as predicted by the proposed formula agree well with the empirical powers from the simulations. The proposed methods are illustrated using real CRT data. We conclude that with appropriate control of type I error rates under small sample sizes, we recommend the use of GEE approach in CRTs with binary outcomes due to fewer assumptions and robustness to the misspecification of the covariance structure. PMID:25345738
Photometry and spectroscopy in the open cluster Alpha Persei, 2
NASA Technical Reports Server (NTRS)
Prosser, Charles F.
1993-01-01
Results from a combination of new spectroscopic and photometric observations in the lower main-sequence and pre-main sequence of the open cluster alpha Persei are presented. New echelle spectroscopy has provided radial and rotational velocity information for thirteen candidate members, three of which are nonmembers based on radial velocity, absence of a Li 6707A feature, and absence of H-alpha emission. A set of revised rotational velocity estimates for several slowly rotating candidates identified earlier is given, yielding rotational velocities as low as 7 km/s for two apparent cluster members. VRI photometry for several pre-main sequence members is given; the new (V,V-I(sub K)) photometry yields a more clearly defined pre-main sequence. A list of approximately 43 new faint candidate members based on the (V,V-I(sub K)) CCD photometry is presented in an effort to identify additional cluster members at very low masses. Low-dispersion spectra obtained for several of these candidates provide in some cases supporting evidence for cluster membership. The single brown dwarf candidate in this cluster is for the first time placed in a color-magnitude diagram with other cluster members, providing a better means for establishing its true status. Stars from among the list of new photometric candidates may provide the means for establishing a sequence of cluster members down to very faint magnitudes (V approximately 21) and consequently very low masses. New coordinate determinations for previous candidate members and finding charts for the new photometric candidates are provided in appendices.
Kamarudin, Nur Diyana; Ooi, Chia Yee; Kawanabe, Tadaaki; Odaguchi, Hiroshi; Kobayashi, Fuminori
2017-01-01
In tongue diagnosis, colour information of tongue body has kept valuable information regarding the state of disease and its correlation with the internal organs. Qualitatively, practitioners may have difficulty in their judgement due to the instable lighting condition and naked eye's ability to capture the exact colour distribution on the tongue especially the tongue with multicolour substance. To overcome this ambiguity, this paper presents a two-stage tongue's multicolour classification based on a support vector machine (SVM) whose support vectors are reduced by our proposed k -means clustering identifiers and red colour range for precise tongue colour diagnosis. In the first stage, k -means clustering is used to cluster a tongue image into four clusters of image background (black), deep red region, red/light red region, and transitional region. In the second-stage classification, red/light red tongue images are further classified into red tongue or light red tongue based on the red colour range derived in our work. Overall, true rate classification accuracy of the proposed two-stage classification to diagnose red, light red, and deep red tongue colours is 94%. The number of support vectors in SVM is improved by 41.2%, and the execution time for one image is recorded as 48 seconds.
A High-precision Trigonometric Parallax to an Ancient Metal-poor Globular Cluster
NASA Astrophysics Data System (ADS)
Brown, T. M.; Casertano, S.; Strader, J.; Riess, A.; VandenBerg, D. A.; Soderblom, D. R.; Kalirai, J.; Salinas, R.
2018-03-01
Using the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST), we have obtained a direct trigonometric parallax for the nearest metal-poor globular cluster, NGC 6397. Although trigonometric parallaxes have been previously measured for many nearby open clusters, this is the first parallax for an ancient metal-poor population—one that is used as a fundamental template in many stellar population studies. This high-precision measurement was enabled by the HST/WFC3 spatial-scanning mode, providing hundreds of astrometric measurements for dozens of stars in the cluster and also for Galactic field stars along the same sightline. We find a parallax of 0.418 ± 0.013 ± 0.018 mas (statistical, systematic), corresponding to a true distance modulus of 11.89 ± 0.07 ± 0.09 mag (2.39 ± 0.07 ± 0.10 kpc). The V luminosity at the stellar main-sequence turnoff implies an absolute cluster age of 13.4 ± 0.7 ± 1.2 Gyr. Based on observations made with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555. These observations are associated with programs GO-13817, GO-14336, and GO-14773.
Ooi, Chia Yee; Kawanabe, Tadaaki; Odaguchi, Hiroshi; Kobayashi, Fuminori
2017-01-01
In tongue diagnosis, colour information of tongue body has kept valuable information regarding the state of disease and its correlation with the internal organs. Qualitatively, practitioners may have difficulty in their judgement due to the instable lighting condition and naked eye's ability to capture the exact colour distribution on the tongue especially the tongue with multicolour substance. To overcome this ambiguity, this paper presents a two-stage tongue's multicolour classification based on a support vector machine (SVM) whose support vectors are reduced by our proposed k-means clustering identifiers and red colour range for precise tongue colour diagnosis. In the first stage, k-means clustering is used to cluster a tongue image into four clusters of image background (black), deep red region, red/light red region, and transitional region. In the second-stage classification, red/light red tongue images are further classified into red tongue or light red tongue based on the red colour range derived in our work. Overall, true rate classification accuracy of the proposed two-stage classification to diagnose red, light red, and deep red tongue colours is 94%. The number of support vectors in SVM is improved by 41.2%, and the execution time for one image is recorded as 48 seconds. PMID:29065640
Knutson, Stacy T.; Westwood, Brian M.; Leuthaeuser, Janelle B.; Turner, Brandon E.; Nguyendac, Don; Shea, Gabrielle; Kumar, Kiran; Hayden, Julia D.; Harper, Angela F.; Brown, Shoshana D.; Morris, John H.; Ferrin, Thomas E.; Babbitt, Patricia C.
2017-01-01
Abstract Protein function identification remains a significant problem. Solving this problem at the molecular functional level would allow mechanistic determinant identification—amino acids that distinguish details between functional families within a superfamily. Active site profiling was developed to identify mechanistic determinants. DASP and DASP2 were developed as tools to search sequence databases using active site profiling. Here, TuLIP (Two‐Level Iterative clustering Process) is introduced as an iterative, divisive clustering process that utilizes active site profiling to separate structurally characterized superfamily members into functionally relevant clusters. Underlying TuLIP is the observation that functionally relevant families (curated by Structure‐Function Linkage Database, SFLD) self‐identify in DASP2 searches; clusters containing multiple functional families do not. Each TuLIP iteration produces candidate clusters, each evaluated to determine if it self‐identifies using DASP2. If so, it is deemed a functionally relevant group. Divisive clustering continues until each structure is either a functionally relevant group member or a singlet. TuLIP is validated on enolase and glutathione transferase structures, superfamilies well‐curated by SFLD. Correlation is strong; small numbers of structures prevent statistically significant analysis. TuLIP‐identified enolase clusters are used in DASP2 GenBank searches to identify sequences sharing functional site features. Analysis shows a true positive rate of 96%, false negative rate of 4%, and maximum false positive rate of 4%. F‐measure and performance analysis on the enolase search results and comparison to GEMMA and SCI‐PHY demonstrate that TuLIP avoids the over‐division problem of these methods. Mechanistic determinants for enolase families are evaluated and shown to correlate well with literature results. PMID:28054422
The Distance to the Coma Cluster from the Tully--Fisher Relation
NASA Astrophysics Data System (ADS)
Herter, T.; Vogt, N. P.; Haynes, M. P.; Giovanelli, R.
1993-12-01
As part of a survey to determine the distances to nearby (z < .04) Abell clusters via application of the Tully--Fisher (TF) relation, we have obtained 21 cm HI line widths, optical rotation curves and photometric I--band CCD images of galaxies within and near the Coma cluster. Because spiral galaxies within the cluster itself are HI deficient and thus are detected marginally or not at all in HI, distance determinations using only the radio TF relation exclude true cluster members. Our sample includes eight HI deficient galaxies within 1.5 degrees of the cluster center, for which optical velocity widths are derived from their Hα and [NII] rotation curves. The 21 cm line widths have been extracted using a new algorithm designed to optimize the measurement for TF applications, taking into account the effects of spectral resolution and smoothing. The optical width is constructed from the velocity histogram, and is therefore a global value akin to the HI width. A correction for turbulent broadening of the HI is derived from comparison of the optical and HI widths. Using a combined sample of 260 galaxies in 11 clusters and an additional 30 field objects at comparable distances, we have performed a calibration of the radio and optical analogs of the TF relation. Preliminary results show a clear linear relationship with a small offset between optical and radio widths, and good agreement in deriving Tully--Fisher distances to clusters. Our Coma sample consists of 28 galaxies with optical widths and 42 with HI line widths, with an overlapping set of 20 galaxies. We will present the data on the Coma cluster, and discuss the results of our analysis.
Knutson, Stacy T; Westwood, Brian M; Leuthaeuser, Janelle B; Turner, Brandon E; Nguyendac, Don; Shea, Gabrielle; Kumar, Kiran; Hayden, Julia D; Harper, Angela F; Brown, Shoshana D; Morris, John H; Ferrin, Thomas E; Babbitt, Patricia C; Fetrow, Jacquelyn S
2017-04-01
Protein function identification remains a significant problem. Solving this problem at the molecular functional level would allow mechanistic determinant identification-amino acids that distinguish details between functional families within a superfamily. Active site profiling was developed to identify mechanistic determinants. DASP and DASP2 were developed as tools to search sequence databases using active site profiling. Here, TuLIP (Two-Level Iterative clustering Process) is introduced as an iterative, divisive clustering process that utilizes active site profiling to separate structurally characterized superfamily members into functionally relevant clusters. Underlying TuLIP is the observation that functionally relevant families (curated by Structure-Function Linkage Database, SFLD) self-identify in DASP2 searches; clusters containing multiple functional families do not. Each TuLIP iteration produces candidate clusters, each evaluated to determine if it self-identifies using DASP2. If so, it is deemed a functionally relevant group. Divisive clustering continues until each structure is either a functionally relevant group member or a singlet. TuLIP is validated on enolase and glutathione transferase structures, superfamilies well-curated by SFLD. Correlation is strong; small numbers of structures prevent statistically significant analysis. TuLIP-identified enolase clusters are used in DASP2 GenBank searches to identify sequences sharing functional site features. Analysis shows a true positive rate of 96%, false negative rate of 4%, and maximum false positive rate of 4%. F-measure and performance analysis on the enolase search results and comparison to GEMMA and SCI-PHY demonstrate that TuLIP avoids the over-division problem of these methods. Mechanistic determinants for enolase families are evaluated and shown to correlate well with literature results. © 2017 The Authors Protein Science published by Wiley Periodicals, Inc. on behalf of The Protein Society.
Constraining hydrostatic mass bias of galaxy clusters with high-resolution X-ray spectroscopy
NASA Astrophysics Data System (ADS)
Ota, Naomi; Nagai, Daisuke; Lau, Erwin T.
2018-04-01
Gas motions in galaxy clusters play important roles in determining the properties of the intracluster medium (ICM) and in the constraint of cosmological parameters via X-ray and Sunyaev-Zel'dovich effect observations of galaxy clusters. The Hitomi measurements of gas motions in the core of the Perseus Cluster have provided new insights into the physics in galaxy clusters. The XARM mission, equipped with the Resolve X-ray micro-calorimeter, will continue Hitomi's legacy by measuring ICM motions through Doppler shifting and broadening of emission lines in a larger number of galaxy clusters, and at larger radii. In this work, we investigate how well we can measure bulk and turbulent gas motions in the ICM with XARM, by analyzing mock XARM simulations of galaxy clusters extracted from cosmological hydrodynamic simulations. We assess how photon counts, spectral fitting methods, multiphase ICM structure, deprojections, and region selection affect the measurements of gas motions. We first show that XARM is capable of recovering the underlying spherically averaged turbulent and bulk velocity profiles for dynamically relaxed clusters to within ˜50% with a reasonable amount of photon counts in the X-ray emission lines. We also find that there are considerable azimuthal variations in the ICM velocities, where the velocities measured in a single azimuthal direction can significantly deviate from the true value even in dynamically relaxed systems. Such variation must be taken into account when interpreting data and developing observing strategies. We will discuss the prospect of using the upcoming XARM mission to measure non-thermal pressure and to correct for the hydrostatic mass bias of galaxy clusters. Our results are broadly applicable for future X-ray missions, such as Athena and Lynx.
Eyler, Lauren; Hubbard, Alan; Juillard, Catherine
2016-10-01
Low and middle-income countries (LMICs) and the world's poor bear a disproportionate share of the global burden of injury. Data regarding disparities in injury are vital to inform injury prevention and trauma systems strengthening interventions targeted towards vulnerable populations, but are limited in LMICs. We aim to facilitate injury disparities research by generating a standardized methodology for assessing economic status in resource-limited country trauma registries where complex metrics such as income, expenditures, and wealth index are infeasible to assess. To address this need, we developed a cluster analysis-based algorithm for generating simple population-specific metrics of economic status using nationally representative Demographic and Health Surveys (DHS) household assets data. For a limited number of variables, g, our algorithm performs weighted k-medoids clustering of the population using all combinations of g asset variables and selects the combination of variables and number of clusters that maximize average silhouette width (ASW). In simulated datasets containing both randomly distributed variables and "true" population clusters defined by correlated categorical variables, the algorithm selected the correct variable combination and appropriate cluster numbers unless variable correlation was very weak. When used with 2011 Cameroonian DHS data, our algorithm identified twenty economic clusters with ASW 0.80, indicating well-defined population clusters. This economic model for assessing health disparities will be used in the new Cameroonian six-hospital centralized trauma registry. By describing our standardized methodology and algorithm for generating economic clustering models, we aim to facilitate measurement of health disparities in other trauma registries in resource-limited countries. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Constraining hydrostatic mass bias of galaxy clusters with high-resolution X-ray spectroscopy
NASA Astrophysics Data System (ADS)
Ota, Naomi; Nagai, Daisuke; Lau, Erwin T.
2018-06-01
Gas motions in galaxy clusters play important roles in determining the properties of the intracluster medium (ICM) and in the constraint of cosmological parameters via X-ray and Sunyaev-Zel'dovich effect observations of galaxy clusters. The Hitomi measurements of gas motions in the core of the Perseus Cluster have provided new insights into the physics in galaxy clusters. The XARM mission, equipped with the Resolve X-ray micro-calorimeter, will continue Hitomi's legacy by measuring ICM motions through Doppler shifting and broadening of emission lines in a larger number of galaxy clusters, and at larger radii. In this work, we investigate how well we can measure bulk and turbulent gas motions in the ICM with XARM, by analyzing mock XARM simulations of galaxy clusters extracted from cosmological hydrodynamic simulations. We assess how photon counts, spectral fitting methods, multiphase ICM structure, deprojections, and region selection affect the measurements of gas motions. We first show that XARM is capable of recovering the underlying spherically averaged turbulent and bulk velocity profiles for dynamically relaxed clusters to within ˜50% with a reasonable amount of photon counts in the X-ray emission lines. We also find that there are considerable azimuthal variations in the ICM velocities, where the velocities measured in a single azimuthal direction can significantly deviate from the true value even in dynamically relaxed systems. Such variation must be taken into account when interpreting data and developing observing strategies. We will discuss the prospect of using the upcoming XARM mission to measure non-thermal pressure and to correct for the hydrostatic mass bias of galaxy clusters. Our results are broadly applicable for future X-ray missions, such as Athena and Lynx.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berman, Benjamin P.; Pfeiffer, Barret D.; Laverty, Todd R.
2004-08-06
Background The identification of sequences that control transcription in metazoans is a major goal of genome analysis. In a previous study, we demonstrated that searching for clusters of predicted transcription factor binding sites could discover active regulatory sequences, and identified 37 regions of the Drosophila melanogaster genome with high densities of predicted binding sites for five transcription factors involved in anterior-posterior embryonic patterning. Nine of these clusters overlapped known enhancers. Here, we report the results of in vivo functional analysis of 27 remaining clusters. Results We generated transgenic flies carrying each cluster attached to a basal promoter and reporter gene,more » and assayed embryos for reporter gene expression. Six clusters are enhancers of adjacent genes: giant, fushi tarazu, odd-skipped, nubbin, squeeze and pdm2; three drive expression in patterns unrelated to those of neighboring genes; the remaining 18 do not appear to have enhancer activity. We used the Drosophila pseudoobscura genome to compare patterns of evolution in and around the 15 positive and 18 false-positive predictions. Although conservation of primary sequence cannot distinguish true from false positives, conservation of binding-site clustering accurately discriminates functional binding-site clusters from those with no function. We incorporated conservation of binding-site clustering into a new genome-wide enhancer screen, and predict several hundred new regulatory sequences, including 85 adjacent to genes with embryonic patterns. Conclusions Measuring conservation of sequence features closely linked to function - such as binding-site clustering - makes better use of comparative sequence data than commonly used methods that examine only sequence identity.« less
A Random Walk Approach to Query Informative Constraints for Clustering.
Abin, Ahmad Ali
2017-08-09
This paper presents a random walk approach to the problem of querying informative constraints for clustering. The proposed method is based on the properties of the commute time, that is the expected time taken for a random walk to travel between two nodes and return, on the adjacency graph of data. Commute time has the nice property of that, the more short paths connect two given nodes in a graph, the more similar those nodes are. Since computing the commute time takes the Laplacian eigenspectrum into account, we use this property in a recursive fashion to query informative constraints for clustering. At each recursion, the proposed method constructs the adjacency graph of data and utilizes the spectral properties of the commute time matrix to bipartition the adjacency graph. Thereafter, the proposed method benefits from the commute times distance on graph to query informative constraints between partitions. This process iterates for each partition until the stop condition becomes true. Experiments on real-world data show the efficiency of the proposed method for constraints selection.
Holographic optical coherence imaging of tumor spheroids
NASA Astrophysics Data System (ADS)
Yu, P.; Mustata, M.; Turek, J. J.; French, P. M. W.; Melloch, M. R.; Nolte, D. D.
2003-07-01
We present depth-resolved coherence-domain images of living tissue using a dynamic holographic semiconductor film. An AlGaAs photorefractive quantum-well device is used in an adaptive interferometer that records coherent backscattered (image-bearing) light from inside rat osteogenic sarcoma tumor spheroids up to 1 mm in diameter in vitro. The data consist of sequential holographic image frames at successive depths through the tumor represented as a visual video "fly-through." The images from the tumor spheroids reveal heterogeneous structures presumably caused by necrosis and microcalcifications characteristic of human tumors in their early avascular growth.
NASA Astrophysics Data System (ADS)
Katori, Makoto
1988-12-01
A new scheme of the coherent-anomaly method (CAM) is proposed to study critical phenomena in the models for which a mean-field description gives spurious first-order phase transition. A canonical series of mean-field-type approximations are constructed so that the spurious discontinuity should vanish asymptotically as the approximate critical temperature approachs the true value. The true value of the critical exponents β and γ are related to the coherent-anomaly exponents defined among the classical approximations. The formulation is demonstrated in the two-dimensional q-state Potts models for q{=}3 and 4. The result shows that the present method enables us to estimate the critical exponents with high accuracy by using the date of the cluster-mean-field approximations.
Crowded Cluster Cores. Algorithms for Deblending in Dark Energy Survey Images
Zhang, Yuanyuan; McKay, Timothy A.; Bertin, Emmanuel; ...
2015-10-26
Deep optical images are often crowded with overlapping objects. We found that this is especially true in the cores of galaxy clusters, where images of dozens of galaxies may lie atop one another. Accurate measurements of cluster properties require deblending algorithms designed to automatically extract a list of individual objects and decide what fraction of the light in each pixel comes from each object. In this article, we introduce a new software tool called the Gradient And Interpolation based (GAIN) deblender. GAIN is used as a secondary deblender to improve the separation of overlapping objects in galaxy cluster cores inmore » Dark Energy Survey images. It uses image intensity gradients and an interpolation technique originally developed to correct flawed digital images. Our paper is dedicated to describing the algorithm of the GAIN deblender and its applications, but we additionally include modest tests of the software based on real Dark Energy Survey co-add images. GAIN helps to extract an unbiased photometry measurement for blended sources and improve detection completeness, while introducing few spurious detections. When applied to processed Dark Energy Survey data, GAIN serves as a useful quick fix when a high level of deblending is desired.« less
DRY MERGER RATE AND POST-MERGER FRACTION IN THE COMA CLUSTER CORE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cordero, Juan P.; Campusano, Luis E.; Haines, Christopher P.
2016-01-20
We evaluate the dry merger activity in the Coma cluster, using a spectroscopically complete sample of 70 red-sequence (RS) galaxies, most of which (∼75%) are located within 0.2R{sub 200} (∼0.5 Mpc) from the cluster center, with data from the Coma Treasury Survey obtained with the Hubble Space Telescope. The fraction of close galaxy pairs in the sample is the proxy employed for the estimation of the merger activity. We identify 5 pairs and 1 triplet, enclosing a total of 13 galaxies, based on limits on projected separation and line-of-sight velocity difference. Of these systems, none show signs of ongoing interaction,more » and therefore we do not find any true mergers in our sample. This negative result sets a 1σ upper limit of 1.5% per Gyr for the major dry merger rate, consistent with the low rates expected in present-day clusters. Detailed examination of the images of all the RS galaxies in the sample reveals only one with low surface brightness features identifiable as the remnant of a past merger or interaction, implying a post-merger fraction below 2%.« less
Scale dependence of the 200-mb divergence inferred from EOLE data.
NASA Technical Reports Server (NTRS)
Morel, P.; Necco, G.
1973-01-01
The EOLE experiment with 480 constant-volume balloons distributed over the Southern Hemisphere approximately at the 200-mb level, has provided a unique, highly accurate set of tracer trajectories in the general westerly circulation. The trajectories of neighboring balloons are analyzed to estimate the horizontal divergence from the Lagrangian derivative of the area of one cluster. The variance of the divergence estimates results from two almost comparable effects: the true divergence of the horizontal flow and eddy diffusion due to small-scale, two-dimensional turbulence. Taking this into account, the rms divergence is found to be of the order of 0.00001 per sec and decreases logarithmically with cluster size. This scale dependence is shown to be consistent with the quasi-geostrophic turbulence model of the general circulation in midlatitudes.
Redshift Space Distortion on the Small Scale Clustering of Structure
NASA Astrophysics Data System (ADS)
Park, Hyunbae; Sabiu, Cristiano; Li, Xiao-dong; Park, Changbom; Kim, Juhan
2018-01-01
The positions of galaxies in comoving Cartesian space varies under different cosmological parameter choices, inducing a redshift-dependent scaling in the galaxy distribution. The shape of the two-point correlation of galaxies exhibits a significant redshift evolution when the galaxy sample is analyzed under a cosmology differing from the true, simulated one. In our previous works, we can made use of this geometrical distortion to constrain the values of cosmological parameters governing the expansion history of the universe. This current work is a continuation of our previous works as a strategy to constrain cosmological parameters using redshift-invariant physical quantities. We now aim to understand the redshift evolution of the full shape of the small scale, anisotropic galaxy clustering and give a firmer theoretical footing to our previous works.
NASA Technical Reports Server (NTRS)
Ford, H. C.; Ciardullo, R.; Harms, R. J.; Bartko, F.
1981-01-01
The radial velocities of cluster members of two rich, large superclusters have been measured in order to probe the supercluster mass densities, and simple evolutionary models have been computed to place limits upon the mass density within each supercluster. These superclusters represent true physical associations of size of about 100 Mpc seen presently at an early stage of evolution. One supercluster is weakly bound, the other probably barely bound, but possibly marginally unbound. Gravity has noticeably slowed the Hubble expansion of both superclusters. Galaxy surface-density counts and the density enhancement of Abell clusters within each supercluster were used to derive the ratio of mass densities of the superclusters to the mean field mass density. The results strongly exclude a closed universe.
The sensitivity of harassment to orbit: mass loss from early-type dwarfs in galaxy clusters
NASA Astrophysics Data System (ADS)
Smith, R.; Sánchez-Janssen, R.; Beasley, M. A.; Candlish, G. N.; Gibson, B. K.; Puzia, T. H.; Janz, J.; Knebe, A.; Aguerri, J. A. L.; Lisker, T.; Hensler, G.; Fellhauer, M.; Ferrarese, L.; Yi, S. K.
2015-12-01
We conduct a comprehensive numerical study of the orbital dependence of harassment on early-type dwarfs consisting of 168 different orbits within a realistic, Virgo-like cluster, varying in eccentricity and pericentre distance. We find harassment is only effective at stripping stars or truncating their stellar discs for orbits that enter deep into the cluster core. Comparing to the orbital distribution in cosmological simulations, we find that the majority of the orbits (more than three quarters) result in no stellar mass loss. We also study the effects on the radial profiles of the globular cluster systems of early-type dwarfs. We find these are significantly altered only if harassment is very strong. This suggests that perhaps most early-type dwarfs in clusters such as Virgo have not suffered any tidal stripping of stars or globular clusters due to harassment, as these components are safely embedded deep within their dark matter halo. We demonstrate that this result is actually consistent with an earlier study of harassment of dwarf galaxies, despite the apparent contradiction. Those few dwarf models that do suffer stellar stripping are found out to the virial radius of the cluster at redshift = 0, which mixes them in with less strongly harassed galaxies. However when placed on phase-space diagrams, strongly harassed galaxies are found offset to lower velocities compared to weakly harassed galaxies. This remains true in a cosmological simulation, even when haloes have a wide range of masses and concentrations. Thus phase-space diagrams may be a useful tool for determining the relative likelihood that galaxies have been strongly or weakly harassed.
THE DETECTION AND STATISTICS OF GIANT ARCS BEHIND CLASH CLUSTERS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Bingxiao; Zheng, Wei; Postman, Marc
We developed an algorithm to find and characterize gravitationally lensed galaxies (arcs) to perform a comparison of the observed and simulated arc abundance. Observations are from the Cluster Lensing And Supernova survey with Hubble (CLASH). Simulated CLASH images are created using the MOKA package and also clusters selected from the high-resolution, hydrodynamical simulations, MUSIC, over the same mass and redshift range as the CLASH sample. The algorithm's arc elongation accuracy, completeness, and false positive rate are determined and used to compute an estimate of the true arc abundance. We derive a lensing efficiency of 4 ± 1 arcs (with length ≥6″ andmore » length-to-width ratio ≥7) per cluster for the X-ray-selected CLASH sample, 4 ± 1 arcs per cluster for the MOKA-simulated sample, and 3 ± 1 arcs per cluster for the MUSIC-simulated sample. The observed and simulated arc statistics are in full agreement. We measure the photometric redshifts of all detected arcs and find a median redshift z{sub s} = 1.9 with 33% of the detected arcs having z{sub s} > 3. We find that the arc abundance does not depend strongly on the source redshift distribution but is sensitive to the mass distribution of the dark matter halos (e.g., the c–M relation). Our results show that consistency between the observed and simulated distributions of lensed arc sizes and axial ratios can be achieved by using cluster-lensing simulations that are carefully matched to the selection criteria used in the observations.« less
Michel, Christian; Pelletier, Claire; Boussaha, Mekki; Douet, Diane-Gaëlle; Lautraite, Armand; Tailliez, Patrick
2007-05-01
Lactic acid bacteria have become a major source of concern for aquaculture in recent decades. In addition to true pathogenic species of worldwide significance, such as Streptococcus iniae and Lactococcus garvieae, several species have been reported to produce occasional fish mortalities in limited geographic areas, and many unidentifiable or ill-defined isolates are regularly isolated from fish or fish products. To clarify the nature and prevalence of different fish-associated bacteria belonging to the lactic acid bacterium group, a collection of 57 isolates of different origins was studied and compared with a set of 22 type strains, using amplified rRNA gene restriction analysis (ARDRA). Twelve distinct clusters were delineated on the basis of ARDRA profiles and were confirmed by sequencing of sodA and 16S rRNA genes. These clusters included the following: Lactococcus raffinolactis, L. garvieae, Lactococcus l., S. iniae, S. dysgalactiae, S. parauberis, S. agalactiae, Carnobacterium spp., the Enterococcus "faecium" group, a heterogeneous Enterococcus-like cluster comprising indiscernible representatives of Vagococcus fluvialis or the recently recognized V. carniphilus, V. salmoninarum, and Aerococcus spp. Interestingly, the L. lactis and L. raffinolactis clusters appeared to include many commensals of fish, so opportunistic infections caused by these species cannot be disregarded. The significance for fish populations and fish food processing of three or four genetic clusters of uncertain or complex definition, namely, Aerococcus and Enterococcus clusters, should be established more accurately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Zhaoying; Liu, Bingwen; Zhao, Evan
For the first time, the use of an argon cluster ion sputtering source has been demonstrated to perform superiorly relative to traditional oxygen and cesium ion sputtering sources for ToF-SIMS depth profiling of insulating materials. The superior performance has been attributed to effective alleviation of surface charging. A simulated nuclear waste glass, SON68, and layered hole-perovskite oxide thin films were selected as model systems due to their fundamental and practical significance. Our study shows that if the size of analysis areas is same, the highest sputter rate of argon cluster sputtering can be 2-3 times faster than the highest sputtermore » rates of oxygen or cesium sputtering. More importantly, high quality data and high sputter rates can be achieved simultaneously for argon cluster sputtering while this is not the case for cesium and oxygen sputtering. Therefore, for deep depth profiling of insulating samples, the measurement efficiency of argon cluster sputtering can be about 6-15 times better than traditional cesium and oxygen sputtering. Moreover, for a SrTiO3/SrCrO3 bi-layer thin film on a SrTiO3 substrate, the true 18O/16O isotopic distribution at the interface is better revealed when using the argon cluster sputtering source. Therefore, the implementation of an argon cluster sputtering source can significantly improve the measurement efficiency of insulating materials, and thus can expand the application of ToF-SIMS to the study of glass corrosion, perovskite oxide thin films, and many other potential systems.« less
Combining Image Processing with Signal Processing to Improve Transmitter Geolocation Estimation
2014-03-27
transmitter by searching a grid of possible transmitter locations within the image region. At each evaluated grid point, theoretical TDOA values are computed...requires converting the image to a grayscale intensity image. This allows efficient manipulation of data and ease of comparison among pixel values . The...cluster of redundant y values along the top edge of an ideal rectangle. The same is true for the bottom edge, as well as for the x values along the
Orchiectomy for suspected microscopic tumor in patients with anti-Ma2-associated encephalitis.
Mathew, R M; Vandenberghe, R; Garcia-Merino, A; Yamamoto, T; Landolfi, J C; Rosenfeld, M R; Rossi, J E; Thiessen, B; Dropcho, E J; Dalmau, J
2007-03-20
To report the presence of microscopic neoplasms of the testis in men with anti-Ma2-associated encephalitis (Ma2-encephalitis) and to discuss the clinical implications. Orchiectomy specimens were examined using immunohistochemistry with Ma2 and Oct4 antibodies. Among 25 patients with Ma2-encephalitis younger than 50 years, 19 had germ-cell tumors, and 6 had no evidence of cancer. These 6 patients underwent orchiectomy because they fulfilled five criteria: 1) demonstration of anti-Ma2 antibodies in association with MRI or clinical features compatible with Ma2-encephalitis, 2) life-threatening or progressive neurologic deficits, 3) age < 50 years, 4) absence of other tumors, and 5) new testicular enlargement or risk factors for germ-cell tumors, mainly cryptorchidism or ultrasound evidence of testicular microcalcifications. All orchiectomy specimens showed intratubular-germ cell neoplasms unclassified type (IGCNU) and other abnormalities including microcalcifications, atrophy, fibrosis, inflammatory infiltrates, or hypospermatogenesis. Ma2 was expressed by neoplastic cells in three of three patients examined. Even though most patients had severe neurologic deficits at the time of orchiectomy (median progression of symptoms, 10 months), 4 had partial improvement and prolonged stabilization (8 to 84 months, median 22.5 months) and two did not improve after the procedure. In young men with Ma2-encephalitis, 1) the disorder should be attributed to a germ-cell neoplasm of the testis unless another Ma2-expressing tumor is found, 2) negative tumor markers, ultrasound, body CT, or PET do not exclude an intratubular germ-cell neoplasm of the testis, and 3) if no tumor is found, the presence of the five indicated criteria should prompt consideration of orchiectomy.
Orchiectomy for suspected microscopic tumor in patients with anti-Ma2-associated encephalitis
Mathew, R.M.; Vandenberghe, R.; Garcia-Merino, A.; Yamamoto, T.; Landolfi, J.C.; Rosenfeld, M.R.; Rossi, J.E.; Thiessen, B.; Dropcho, E.J.; Dalmau, J.
2007-01-01
Objective: To report the presence of microscopic neoplasms of the testis in men with anti-Ma2-associated encephalitis (Ma2-encephalitis) and to discuss the clinical implications. Methods: Orchiectomy specimens were examined using immunohistochemistry with Ma2 and Oct4 antibodies. Results: Among 25 patients with Ma2-encephalitis younger than 50 years, 19 had germ-cell tumors, and 6 had no evidence of cancer. These 6 patients underwent orchiectomy because they fulfilled five criteria: 1) demonstration of anti-Ma2 antibodies in association with MRI or clinical features compatible with Ma2-encephalitis, 2) life-threatening or progressive neurologic deficits, 3) age < 50 years, 4) absence of other tumors, and 5) new testicular enlargement or risk factors for germ-cell tumors, mainly cryptorchidism or ultrasound evidence of testicular microcalcifications. All orchiectomy specimens showed intratubular-germ cell neoplasms unclassified type (IGCNU) and other abnormalities including microcalcifications, atrophy, fibrosis, inflammatory infiltrates, or hypospermatogenesis. Ma2 was expressed by neoplastic cells in three of three patients examined. Even though most patients had severe neurologic deficits at the time of orchiectomy (median progression of symptoms, 10 months), 4 had partial improvement and prolonged stabilization (8 to 84 months, median 22.5 months) and two did not improve after the procedure. Conclusions: In young men with Ma2-encephalitis, 1) the disorder should be attributed to a germ-cell neoplasm of the testis unless another Ma2-expressing tumor is found, 2) negative tumor markers, ultrasound, body CT, or PET do not exclude an intratubular germ-cell neoplasm of the testis, and 3) if no tumor is found, the presence of the five indicated criteria should prompt consideration of orchiectomy. PMID:17151337
Esen, Gül; Tutar, Burçin; Uras, Cihan; Calay, Zerrin; İnce, Ümit; Tutar, Onur
2016-01-01
PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195 patients (median age 53 years, range 32–80 years) with 198 microcalcification-only lesions with a follow-up of at least one year were included in the study. The location of the lesion relative to the needle was determined from the postfire images, and unlike the conventional technique, tissue retrieval was predominantly performed from that location, followed by a complete 360° rotation, if needed. RESULTS The median core number was 8.5. Biopsy results revealed 135 benign, 24 atypical, and 39 malignant lesions. The total upgrade rate at surgery was 7.7% (6.1% for ductal carcinomas in situ and 10.5% for atypical lesions). Patients with benign lesions were followed up for a median period of 27.5 months, with no interval change. At the follow-up, scar formation was seen in 23 patients (17%); three of the scars were remarkable for resembling a malignancy. CONCLUSION Our biposy method is fast and practical, and it is easily tolerated by patients without compromising accuracy. Patients with a diagnosis of atypia still need to undergo a diagnostic surgical procedure and those with a malignancy need to undergo curative surgery, even if the lesion is totally excised at biopsy. VABB may leave a scar in the breast tissue, which may resemble a malignancy, albeit rarely. PMID:27306660
Lavoué, Vincent; Fritel, Xavier; Antoine, Martine; Beltjens, Françoise; Bendifallah, Sofiane; Boisserie-Lacroix, Martine; Boulanger, Loic; Canlorbe, Geoffroy; Catteau-Jonard, Sophie; Chabbert-Buffet, Nathalie; Chamming's, Foucauld; Chéreau, Elisabeth; Chopier, Jocelyne; Coutant, Charles; Demetz, Julie; Guilhen, Nicolas; Fauvet, Raffaele; Kerdraon, Olivier; Laas, Enora; Legendre, Guillaume; Mathelin, Carole; Nadeau, Cédric; Naggara, Isabelle Thomassin; Ngô, Charlotte; Ouldamer, Lobna; Rafii, Arash; Roedlich, Marie-Noelle; Seror, Jérémy; Séror, Jean-Yves; Touboul, Cyril; Uzan, Catherine; Daraï, Emile
2016-05-01
Screening with breast ultrasound in combination with mammography is needed to investigate a clinical breast mass (Grade B), colored single-pore breast nipple discharge (Grade C), or mastitis (Grade C). The BI-RADS system is recommended for describing and classifying abnormal breast imaging findings. For a breast abscess, a percutaneous biopsy is recommended in the case of a mass or persistent symptoms (Grade C). For mastalgia, when breast imaging is normal, no MRI or breast biopsy is recommended (Grade C). Percutaneous biopsy is recommended for a BI-RADS category 4-5 mass (Grade B). For persistent erythematous nipple or atypical eczema lesions, a nipple biopsy is recommended (Grade C). For distortion and asymmetry, a vacuum core-needle biopsy is recommended due to the risk of underestimation by simple core-needle biopsy (Grade C). For BI-RADS category 4-5 microcalcifications without any ultrasound signal, a minimum 11-G vacuum core-needle biopsy is recommended (Grade B). In the absence of microcalcifications on radiography cores additional samples are recommended (Grade B). For atypical ductal hyperplasia, atypical lobular hyperplasia, lobular carcinoma in situ, flat epithelial atypia, radial scar and mucocele with atypia, surgical excision is commonly recommended (Grade C). Expectant management is feasible after multidisciplinary consensus. For these lesions, when excision margins are not clear, no new excision is recommended except for LCIS characterized as pleomorphic or with necrosis (Grade C). For grade 1 phyllodes tumor, surgical resection with clear margins is recommended. For grade 2 phyllodes tumor, 10mm margins are recommended (Grade C). For papillary breast lesions without atypia, complete disappearance of the radiological signal is recommended (Grade C). For papillary breast lesions with atypia, complete surgical excision is recommended (Grade C). Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Deep learning and three-compartment breast imaging in breast cancer diagnosis
NASA Astrophysics Data System (ADS)
Drukker, Karen; Huynh, Benjamin Q.; Giger, Maryellen L.; Malkov, Serghei; Avila, Jesus I.; Fan, Bo; Joe, Bonnie; Kerlikowske, Karla; Drukteinis, Jennifer S.; Kazemi, Leila; Pereira, Malesa M.; Shepherd, John
2017-03-01
We investigated whether deep learning has potential to aid in the diagnosis of breast cancer when applied to mammograms and biologic tissue composition images derived from three-compartment (3CB) imaging. The dataset contained diagnostic mammograms and 3CB images (water, lipid, and protein content) of biopsy-sampled BIRADS 4 and 5 lesions in 195 patients. In 58 patients, the lesion manifested as a mass (13 malignant vs. 45 benign), in 87 as microcalcifications (19 vs. 68), and in 56 as (focal) asymmetry or architectural distortion (11 vs. 45). Six patients had both a mass and calcifications. For each mammogram and corresponding 3CB images, a 128x128 region of interest containing the lesion was selected by an expert radiologist and used directly as input to a deep learning method pretrained on a very large independent set of non-medical images. We used a nested leave-one-out-by-case (patient) model selection and classification protocol. The area under the ROC curve (AUC) for the task of distinguishing between benign and malignant lesions was used as performance metric. For the cases with mammographic masses, the AUC increased from 0.83 (mammograms alone) to 0.89 (mammograms+3CB, p=.162). For the microcalcification and asymmetry/architectural distortion cases the AUC increased from 0.84 to 0.91 (p=.116) and from 0.61 to 0.87 (p=.006), respectively. Our results indicate great potential for the application of deep learning methods in the diagnosis of breast cancer and additional knowledge of the biologic tissue composition appeared to improve performance, especially for lesions mammographically manifesting as asymmetries or architectural distortions.
NASA Astrophysics Data System (ADS)
Vishnu, Kamalakannan
In 2016, invasive breast cancer was diagnosed in about 246,660 women and 2,600 men. An additional 61,000 new cases of in situ breast cancer was diagnosed in women. Microcalcifications are most common abnormalities detected by mammography for breast cancer, present in about 30% of all malignant breast lesions. Tumor specific biomarkers are used for targeting these abnormalities. Nanoparticles with multimodal and combinatorial therapies and conjunction of bio-ligands for specific molecular targeting using surface modifications effectually deliver a variety of drugs and are simultaneously used to image tumor progression. Alendronate, a germinal bisphosphonate conjugation as a targeting ligand would improve the nanoparticle's direct binding to hydroxyapatite (HA) mimicking calcified spots in breast cancer lesions. In this study, the hydrophobically modified glycol chitosan (HGC) micelle was modified with alendronate surface functionalization using a biotin-avidin interaction to improve the nanomicelle's calcification targeting ability. Biotinylated, avidinlyated hydrophobically modified iv glycol chitosan particles were linked to biotinylated alendronate via a strong biotin-avidin linkage. Cyanine 3, a red fluorescent dye was conjugated to the amine groups on HGC for visualization of micelles. The size of the nanoparticles measured was 254.0 +/- 0.43 nm and 209.7 +/- 1.0 nm for Cy3- BHGCA and Cy3-BHGCA-BALN nanoparticles respectively. The average surface charge was measured to be +26.9 +/- 0.19 mV and +27.68 +/- 0.20 mV for Cy3-BHGCA and Cy3-BHGCA- BALN nanoparticles respectively. Binding affinity using hydroxyapatite (HA) revealed that both Cy3 BHGCA BALN and Cy3 BHGCA nanoparticles displayed 95% binding in 24 hours. However, the biotin quenched nanoparticle Cy3 BHGCAB displayed 68% binding in 24 hours. The synthesis and binding chemistry was verified using Fourier transform infrared spectroscopy (FTIR).
NASA Astrophysics Data System (ADS)
Anick, David J.
2003-12-01
A method is described for a rapid prediction of B3LYP-optimized geometries for polyhedral water clusters (PWCs). Starting with a database of 121 B3LYP-optimized PWCs containing 2277 H-bonds, linear regressions yield formulas correlating O-O distances, O-O-O angles, and H-O-H orientation parameters, with local and global cluster descriptors. The formulas predict O-O distances with a rms error of 0.85 pm to 1.29 pm and predict O-O-O angles with a rms error of 0.6° to 2.2°. An algorithm is given which uses the O-O and O-O-O formulas to determine coordinates for the oxygen nuclei of a PWC. The H-O-H formulas then determine positions for two H's at each O. For 15 test clusters, the gap between the electronic energy of the predicted geometry and the true B3LYP optimum ranges from 0.11 to 0.54 kcal/mol or 4 to 18 cal/mol per H-bond. Linear regression also identifies 14 parameters that strongly correlate with PWC electronic energy. These descriptors include the number of H-bonds in which both oxygens carry a non-H-bonding H, the number of quadrilateral faces, the number of symmetric angles in 5- and in 6-sided faces, and the square of the cluster's estimated dipole moment.
Least squares regression methods for clustered ROC data with discrete covariates.
Tang, Liansheng Larry; Zhang, Wei; Li, Qizhai; Ye, Xuan; Chan, Leighton
2016-07-01
The receiver operating characteristic (ROC) curve is a popular tool to evaluate and compare the accuracy of diagnostic tests to distinguish the diseased group from the nondiseased group when test results from tests are continuous or ordinal. A complicated data setting occurs when multiple tests are measured on abnormal and normal locations from the same subject and the measurements are clustered within the subject. Although least squares regression methods can be used for the estimation of ROC curve from correlated data, how to develop the least squares methods to estimate the ROC curve from the clustered data has not been studied. Also, the statistical properties of the least squares methods under the clustering setting are unknown. In this article, we develop the least squares ROC methods to allow the baseline and link functions to differ, and more importantly, to accommodate clustered data with discrete covariates. The methods can generate smooth ROC curves that satisfy the inherent continuous property of the true underlying curve. The least squares methods are shown to be more efficient than the existing nonparametric ROC methods under appropriate model assumptions in simulation studies. We apply the methods to a real example in the detection of glaucomatous deterioration. We also derive the asymptotic properties of the proposed methods. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Klee, Sonja; Derpmann, Valerie; Wißdorf, Walter; Klopotowski, Sebastian; Kersten, Hendrik; Brockmann, Klaus J; Benter, Thorsten; Albrecht, Sascha; Bruins, Andries P; Dousty, Faezeh; Kauppila, Tiina J; Kostiainen, Risto; O'Brien, Rob; Robb, Damon B; Syage, Jack A
2014-08-01
It is well documented since the early days of the development of atmospheric pressure ionization methods, which operate in the gas phase, that cluster ions are ubiquitous. This holds true for atmospheric pressure chemical ionization, as well as for more recent techniques, such as atmospheric pressure photoionization, direct analysis in real time, and many more. In fact, it is well established that cluster ions are the primary carriers of the net charge generated. Nevertheless, cluster ion chemistry has only been sporadically included in the numerous proposed ionization mechanisms leading to charged target analytes, which are often protonated molecules. This paper series, consisting of two parts, attempts to highlight the role of cluster ion chemistry with regard to the generation of analyte ions. In addition, the impact of the changing reaction matrix and the non-thermal collisions of ions en route from the atmospheric pressure ion source to the high vacuum analyzer region are discussed. This work addresses such issues as extent of protonation versus deuteration, the extent of analyte fragmentation, as well as highly variable ionization efficiencies, among others. In Part 1, the nature of the reagent ion generation is examined, as well as the extent of thermodynamic versus kinetic control of the resulting ion population entering the analyzer region.
Galaxy Clusters, Near and Far, Have a Lot in Common
NASA Astrophysics Data System (ADS)
2005-04-01
Using two orbiting X-ray telescopes, a team of international astronomers has examined distant galaxy clusters in order to compare them with their counterparts that are relatively close by. Speaking today at the RAS National Astronomy Meeting in Birmingham, Dr. Ben Maughan (Harvard-Smithsonian Center for Astrophysics), presented the results of this new analysis. The observations indicate that, despite the great expansion that the Universe has undergone since the Big Bang, galaxy clusters both local and distant have a great deal in common. This discovery could eventually lead to a better understanding of how to "weigh" these enormous structures, and, in so doing, answer important questions about the nature and structure of the Universe. Clusters of galaxies, the largest known gravitationally-bound objects, are the knots in the cosmic web of structure that permeates the Universe. Theoretical models make predictions about the number, distribution and properties of these clusters. Scientists can test and improve models of the Universe by comparing these predictions with observations. The most powerful way of doing this is to measure the masses of galaxy clusters, particularly those in the distant Universe. However, weighing galaxy clusters is extremely difficult. One relatively easy way to weigh a galaxy cluster is to use simple laws ("scaling relations") to estimate its weight from properties that are easy to observe, like its luminosity (brightness) or temperature. This is like estimating someone's weight from their height if you didn't have any scales. Over the last 3 years, a team of researchers, led by Ben Maughan, has observed 11 distant galaxy clusters with ESA's XMM-Newton and NASA's Chandra X-ray Observatory. The clusters have redshifts of z = 0.6-1.0, which corresponds to distances of 6 to 8 billion light years. This means that we see them as they were when the Universe was half its present age. The survey included two unusual systems, one in which two massive clusters are merging and another extremely massive cluster which appears very "relaxed" and undisturbed. The X-ray data allowed the scientists to measure the temperatures and luminosities of the gas in the clusters. They were then able to infer their total masses, which varied between 200 and 1,100 times the mass of our Milky Way galaxy. These measurements were then used to test whether galaxy clusters of different sizes and located at different distances from us are simply scaled versions of each other -- a condition known as being "self-similar." This is an important characteristic for astronomers to identify if they hope to get the true weights of galaxy clusters. "For example, chocolate bars are strongly self-similar," said Maughan. "If you shrank a king-size bar to a fun-size bar, they would be identical versions of each other but just different sizes." "However, if you shrank a castle to the size of a bungalow, they would be very different structures, despite being the same size. This means that they are not strongly self-similar objects." Another possible type of relationship between clusters is what scientists call "weakly self-similar." In this case, galaxy clusters in the distant universe and those nearby are almost identical to each other, but not exactly the same. (The only differences between them can be accounted for by the expansion of the Universe since the Big Bang.) Although astronomers have known for some time that galaxy clusters are not strongly self-similar, the question of whether or not they are weakly self-similar has remained open. The new results show that as long as astronomers take into account the continuous expansion of the Universe, then galaxy clusters are, in fact, weakly self-similar. This means that the same scaling relations used to weigh nearby galaxy clusters hold true for these very distant clusters. "Our results mean that weighing distant galaxy clusters could become as easy as converting from Fahrenheit to Celsius," said Maughan. "This will help to answer important questions about the nature and structure of the Universe." The other members of the team were: Laurence Jones (University of Birmingham, UK) Harald Ebeling (Institute for Astronomy, HI, USA), and Caleb Scharf (Columbia Astrophysics Laboratory, NY, USA). The observations were made with the European Photon Imaging Camera (EPIC) on XMM and the Advanced Camera for Imaging and Spectroscopy (ACIS) on Chandra. They were part of the WARPS survey of distant galaxy clusters detected by chance in observations made with the UK-US-Dutch ROSAT X-ray satellite. Additional information and images are available at: http://www.sr.bham.ac.uk/~habib/nampr/
Task-Driven Dictionary Learning Based on Mutual Information for Medical Image Classification.
Diamant, Idit; Klang, Eyal; Amitai, Michal; Konen, Eli; Goldberger, Jacob; Greenspan, Hayit
2017-06-01
We present a novel variant of the bag-of-visual-words (BoVW) method for automated medical image classification. Our approach improves the BoVW model by learning a task-driven dictionary of the most relevant visual words per task using a mutual information-based criterion. Additionally, we generate relevance maps to visualize and localize the decision of the automatic classification algorithm. These maps demonstrate how the algorithm works and show the spatial layout of the most relevant words. We applied our algorithm to three different tasks: chest x-ray pathology identification (of four pathologies: cardiomegaly, enlarged mediastinum, right consolidation, and left consolidation), liver lesion classification into four categories in computed tomography (CT) images and benign/malignant clusters of microcalcifications (MCs) classification in breast mammograms. Validation was conducted on three datasets: 443 chest x-rays, 118 portal phase CT images of liver lesions, and 260 mammography MCs. The proposed method improves the classical BoVW method for all tested applications. For chest x-ray, area under curve of 0.876 was obtained for enlarged mediastinum identification compared to 0.855 using classical BoVW (with p-value 0.01). For MC classification, a significant improvement of 4% was achieved using our new approach (with p-value = 0.03). For liver lesion classification, an improvement of 6% in sensitivity and 2% in specificity were obtained (with p-value 0.001). We demonstrated that classification based on informative selected set of words results in significant improvement. Our new BoVW approach shows promising results in clinically important domains. Additionally, it can discover relevant parts of images for the task at hand without explicit annotations for training data. This can provide computer-aided support for medical experts in challenging image analysis tasks.
Patient-perceived changes in the system of values after cancer diagnosis.
Greszta, Elżbieta; Siemińska, Maria J
2011-03-01
A cross-sectional study investigated changes in patients' value systems following a diagnosis of cancer. Fifty patients at 1 to 6 months following cancer diagnosis, were asked to compare their current values with their recollection of past values. Using the Rokeach Value Survey we obtained statistically significant results showing that twenty-seven out of thirty-six values changed their importance from the patients' perspective: 16 values significantly increased, while 11 values significantly decreased in importance. Changes with respect to nine values were insignificant. We indentified clusters of values increasing in importance the most: Religious morality (Salvation, Forgiving, Helpful, Clean), Personal orientation (Self-Respect, True Friendship, Happiness), Self-constriction (Self-Controlled, Obedient, Honest), Family security (Family Security, Responsible), and Delayed gratification (Wisdom, Inner Harmony). We also observed that the following value clusters decreased in importance: Immediate gratification (An Exciting Life, Pleasure, A Comfortable Life); Self-expansion (Capable, Ambitious, Broadminded), Competence (A Sense of Accomplishment, Imaginative, Intellectual). The remaining values belonged to clusters that as a group changed slightly or not at all. Practical implications of the study are discussed.
NASA Astrophysics Data System (ADS)
Calvo, Florent; Bacchus-Montabonel, Marie-Christine
2018-01-01
Recent photochemistry experiments provided evidence for the formation of hydantoin by irradiation of interstellar ice analogues. The significance of these results and the importance of hydantoin in prebiotic chemistry and polypeptide synthesis motivate the present theoretical investigation, in which we analyzed the effects of stepwise hydration on the electronic and thermodynamical properties of the structure of microhydrated hydantoin using a variety of computational approaches. We generally find microhydration to proceed around the hydantoin heterocycle until 5 water molecules are reached, at which stage hydration becomes segregated with a water cluster forming aside the heterocycle. The reactivity of microhydrated hydantoin caused by an impinging proton was evaluated through charge transfer collision cross sections for microhydrated compounds but also for hydantoin on icy grains modeled using a cluster approach mimicking the true hexagonal ice surface. The effects of hydration on charge transfer efficiency are mostly significant when few water molecules are present, and they progressively weaken and stabilize in larger clusters. On the ice substrate, charge transfer essentially contributes to a global increase in the cross sections.
Oblate-Earth Effects on the Calculation of Ec During Spacecraft Reentry
NASA Technical Reports Server (NTRS)
Bacon, John B.; Matney, Mark J.
2017-01-01
The bulge in the Earth at its equator has been shown to lead to a clustering of natural decays biased to occur towards the equator and away from the orbit's extreme latitudes. Such clustering must be considered when predicting the Expectation of Casualty (Ec) during a natural decay because of the clustering of the human population in the same lower latitudes. This study expands upon prior work, and formalizes the correction that must be made to the calculation of the average exposed population density as a result of this effect. Although a generic equation can be derived from this work to approximate the effects of gravitational and atmospheric perturbations on a final decay, such an equation averages certain important subtleties in achieving a best fit over all conditions. The authors recommend that direct simulation be used to calculate the true Ec for any specific entry as a more accurate method. A generic equation is provided, represented as a function of ballistic number and inclination of the entering spacecraft over the credible range of ballistic numbers.
VALIDITY OF HYDROSTATIC EQUILIBRIUM IN GALAXY CLUSTERS FROM COSMOLOGICAL HYDRODYNAMICAL SIMULATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suto, Daichi; Suto, Yasushi; Kawahara, Hajime
2013-04-10
We examine the validity of the hydrostatic equilibrium (HSE) assumption for galaxy clusters using one of the highest-resolution cosmological hydrodynamical simulations. We define and evaluate several effective mass terms corresponding to the Euler equations of gas dynamics, and quantify the degree of the validity of HSE in terms of the mass estimate. We find that the mass estimated under the HSE assumption (the HSE mass) deviates from the true mass by up to {approx}30%. This level of departure from HSE is consistent with the previous claims, but our physical interpretation is rather different. We demonstrate that the inertial term inmore » the Euler equations makes a negligible contribution to the total mass, and the overall gravity of the cluster is balanced by the thermal gas pressure gradient and the gas acceleration term. Indeed, the deviation from the HSE mass is well explained by the acceleration term at almost all radii. We also clarify the confusion of previous work due to the inappropriate application of the Jeans equations in considering the validity of HSE from the gas dynamics extracted from cosmological hydrodynamical simulations.« less
Searching for 300, 000 Degree Gas in the Core of the Phoenix Cluster with HST-COS
NASA Astrophysics Data System (ADS)
McDonald, Michael
2013-10-01
The high central density of the intracluster medium in some galaxy clusters suggests that the hot 10,000,000K gas should cool completely in less than a Hubble time. In these clusters, simple cooling models predict 100-1000 solar masses per year of cooling gas should fuel massive starbursts in the central galaxy. The fact that the typical central cluster galaxy is a massive, "red and dead" elliptical galaxy, with little evidence for a cool ISM, has led to the realization of the "cooling flow problem". It is now thought that mechanical feedback from the central supermassive blackhole, in the form of radio-blown bubbles, is offsetting cooling, leading to an exceptionally precise {residuals of less than 10 percent} balance between cooling and feedback in nearly every galaxy cluster in the local Universe. In the recently-discovered Phoenix cluster, where z=0.596, we observe an 800 solar mass per year starburst within the central galaxy which accounts for about 30 percent of the classical cooling prediction for this system. We speculate that this may represent the first "true" cooling flow, with the factor of 3 difference between cooling and star formation being attributed to star formation efficiency, rather than a problem with cooling. In order to test these predictions, we propose far-UV spectroscopic observations of the OVI 1032A emission line, which probes 10^5.5K gas, in the central galaxy of the Phoenix cluster. If detected at the expected levels, this would provide compelling evidence that the starburst is, indeed, fueled by runaway cooling of the intracluster medium, confirming the presence of the first, bonafide cooling flow.
Rajab, Maher I
2011-11-01
Since the introduction of epiluminescence microscopy (ELM), image analysis tools have been extended to the field of dermatology, in an attempt to algorithmically reproduce clinical evaluation. Accurate image segmentation of skin lesions is one of the key steps for useful, early and non-invasive diagnosis of coetaneous melanomas. This paper proposes two image segmentation algorithms based on frequency domain processing and k-means clustering/fuzzy k-means clustering. The two methods are capable of segmenting and extracting the true border that reveals the global structure irregularity (indentations and protrusions), which may suggest excessive cell growth or regression of a melanoma. As a pre-processing step, Fourier low-pass filtering is applied to reduce the surrounding noise in a skin lesion image. A quantitative comparison of the techniques is enabled by the use of synthetic skin lesion images that model lesions covered with hair to which Gaussian noise is added. The proposed techniques are also compared with an established optimal-based thresholding skin-segmentation method. It is demonstrated that for lesions with a range of different border irregularity properties, the k-means clustering and fuzzy k-means clustering segmentation methods provide the best performance over a range of signal to noise ratios. The proposed segmentation techniques are also demonstrated to have similar performance when tested on real skin lesions representing high-resolution ELM images. This study suggests that the segmentation results obtained using a combination of low-pass frequency filtering and k-means or fuzzy k-means clustering are superior to the result that would be obtained by using k-means or fuzzy k-means clustering segmentation methods alone. © 2011 John Wiley & Sons A/S.
Three candidate double clusters in the LMC: truth or dare?
NASA Astrophysics Data System (ADS)
Dalessandro, Emanuele; Zocchi, Alice; Varri, Anna Lisa; Mucciarelli, Alessio; Bellazzini, Michele; Ferraro, Francesco R.; Lanzoni, Barbara; Lapenna, Emilio; Origlia, Livia
2018-02-01
The Large Magellanic Cloud (LMC) hosts a large number of candidate stellar cluster pairs. Binary stellar clusters provide important clues about cluster formation processes and the evolutionary history of the host galaxy. However, to properly extract and interpret this information, it is crucial to fully constrain the fraction of real binary systems and their physical properties. Here we present a detailed photometric analysis based on ESO-FORS2 images of three candidate cluster multiplets in the LMC, namely SL349-SL353, SL385-SL387-NGC 1922 and NGC 1836-BRHT4b-NGC 1839. For each cluster, we derived ages, structural parameters and morphological properties. We have also estimated the degree of filling of their Roche lobe, as an approximate tool to measure the strength of the tidal perturbations induced by the LMC. We find that the members of the possible pairs SL349-SL353 and BRHT4b-NGC 1839 have a similar age (t = 1.00 ± 0.12 Gyr and t = 140 ± 15 Myr, respectively), thus possibly hinting at a common origin of their member systems. We also find that all candidate pairs in our sample show evidence of intracluster overdensities that can be a possible indication of real binarity. Particularly interesting is the case of SL349-SL353. In fact, SL353 is relatively close to the condition of critical filling, thus suggesting that these systems might actually constitute an energetically bound pair. It is therefore key to pursue a detailed kinematic screening of such clusters, without which, at present, we do not dare making a conclusive statement about the true nature of this putative pair.
Clustering and phase behaviour of attractive active particles with hydrodynamics.
Navarro, Ricard Matas; Fielding, Suzanne M
2015-10-14
We simulate clustering, phase separation and hexatic ordering in a monolayered suspension of active squirming disks subject to an attractive Lennard-Jones-like pairwise interaction potential, taking hydrodynamic interactions between the particles fully into account. By comparing the hydrodynamic case with counterpart simulations for passive and active Brownian particles, we elucidate the relative roles of self-propulsion, interparticle attraction, and hydrodynamic interactions in determining clustering and phase behaviour. Even in the presence of an attractive potential, we find that hydrodynamic interactions strongly suppress the motility induced phase separation that might a priori have been expected in a highly active suspension. Instead, we find only a weak tendency for the particles to form stringlike clusters in this regime. At lower activities we demonstrate phase behaviour that is broadly equivalent to that of the counterpart passive system at low temperatures, characterized by regimes of gas-liquid, gas-solid and liquid-solid phase coexistence. In this way, we suggest that a dimensionless quantity representing the level of activity relative to the strength of attraction plays the role of something like an effective non-equilibrium temperature, counterpart to the (dimensionless) true thermodynamic temperature in the passive system. However there are also some important differences from the equilibrium case, most notably with regards the degree of hexatic ordering, which we discuss carefully.
Kiranyaz, Serkan; Ince, Turker; Pulkkinen, Jenni; Gabbouj, Moncef
2010-01-01
In this paper, we address dynamic clustering in high dimensional data or feature spaces as an optimization problem where multi-dimensional particle swarm optimization (MD PSO) is used to find out the true number of clusters, while fractional global best formation (FGBF) is applied to avoid local optima. Based on these techniques we then present a novel and personalized long-term ECG classification system, which addresses the problem of labeling the beats within a long-term ECG signal, known as Holter register, recorded from an individual patient. Due to the massive amount of ECG beats in a Holter register, visual inspection is quite difficult and cumbersome, if not impossible. Therefore the proposed system helps professionals to quickly and accurately diagnose any latent heart disease by examining only the representative beats (the so called master key-beats) each of which is representing a cluster of homogeneous (similar) beats. We tested the system on a benchmark database where the beats of each Holter register have been manually labeled by cardiologists. The selection of the right master key-beats is the key factor for achieving a highly accurate classification and the proposed systematic approach produced results that were consistent with the manual labels with 99.5% average accuracy, which basically shows the efficiency of the system.
Short-range order in the Ca sub 1-x La sub x F sub 2+x solid solution: 1:0:3 or 1:0:4 clusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laval, J.P.; Abaouz, A.; Frit, B.
1989-08-01
The defect structure of the Ca{sub 1-x}La{sub x}F{sub 2+x} solid solution (0 {le} x {le} 0.38) has been examined at room temperature by powder neutron diffraction. Two kinds of (xxx) interstitial anions, whose respective numbers increase linearly with increasing dopant cation concentration, have been found: one labeled F{sup 0} (x {approx} 0.41) is a true interstitial; the other labeled F{sup {prime}{double prime}} (x {approx} 0.31) can be considered a relaxed normal anion. Two 1:0:n defect clusters are compatible, within the experimental errors, with these results: the 1:0:3 (1V{sub F}, OF{prime}, 3F{sup {double prime}}, 2 La{sup 3+}) and the 1:0:4 (1V{submore » F}, OF{prime}, 4F{sup {double prime}}, 3La{sup 3+}) clusters. Charge balance considerations and comparisons with the homologous Ca{sub 1-x}M{sub x}{sup IV}F{sub 2+2x} solid solutions (M{sup IV} = Th, U) allow us to think that the less dense 1:0:3 cluster is present for the whole domain of both kinds of solid solutions.« less
Population clustering based on copy number variations detected from next generation sequencing data.
Duan, Junbo; Zhang, Ji-Gang; Wan, Mingxi; Deng, Hong-Wen; Wang, Yu-Ping
2014-08-01
Copy number variations (CNVs) can be used as significant bio-markers and next generation sequencing (NGS) provides a high resolution detection of these CNVs. But how to extract features from CNVs and further apply them to genomic studies such as population clustering have become a big challenge. In this paper, we propose a novel method for population clustering based on CNVs from NGS. First, CNVs are extracted from each sample to form a feature matrix. Then, this feature matrix is decomposed into the source matrix and weight matrix with non-negative matrix factorization (NMF). The source matrix consists of common CNVs that are shared by all the samples from the same group, and the weight matrix indicates the corresponding level of CNVs from each sample. Therefore, using NMF of CNVs one can differentiate samples from different ethnic groups, i.e. population clustering. To validate the approach, we applied it to the analysis of both simulation data and two real data set from the 1000 Genomes Project. The results on simulation data demonstrate that the proposed method can recover the true common CNVs with high quality. The results on the first real data analysis show that the proposed method can cluster two family trio with different ancestries into two ethnic groups and the results on the second real data analysis show that the proposed method can be applied to the whole-genome with large sample size consisting of multiple groups. Both results demonstrate the potential of the proposed method for population clustering.
NASA Astrophysics Data System (ADS)
Lehtola, Susi; Tubman, Norm M.; Whaley, K. Birgitta; Head-Gordon, Martin
2017-10-01
Approximate full configuration interaction (FCI) calculations have recently become tractable for systems of unforeseen size, thanks to stochastic and adaptive approximations to the exponentially scaling FCI problem. The result of an FCI calculation is a weighted set of electronic configurations, which can also be expressed in terms of excitations from a reference configuration. The excitation amplitudes contain information on the complexity of the electronic wave function, but this information is contaminated by contributions from disconnected excitations, i.e., those excitations that are just products of independent lower-level excitations. The unwanted contributions can be removed via a cluster decomposition procedure, making it possible to examine the importance of connected excitations in complicated multireference molecules which are outside the reach of conventional algorithms. We present an implementation of the cluster decomposition analysis and apply it to both true FCI wave functions, as well as wave functions generated from the adaptive sampling CI algorithm. The cluster decomposition is useful for interpreting calculations in chemical studies, as a diagnostic for the convergence of various excitation manifolds, as well as as a guidepost for polynomially scaling electronic structure models. Applications are presented for (i) the double dissociation of water, (ii) the carbon dimer, (iii) the π space of polyacenes, and (iv) the chromium dimer. While the cluster amplitudes exhibit rapid decay with an increasing rank for the first three systems, even connected octuple excitations still appear important in Cr2, suggesting that spin-restricted single-reference coupled-cluster approaches may not be tractable for some problems in transition metal chemistry.
Lens models under the microscope: comparison of Hubble Frontier Field cluster magnification maps
NASA Astrophysics Data System (ADS)
Priewe, Jett; Williams, Liliya L. R.; Liesenborgs, Jori; Coe, Dan; Rodney, Steven A.
2017-02-01
Using the power of gravitational lensing magnification by massive galaxy clusters, the Hubble Frontier Fields provide deep views of six patches of the high-redshift Universe. The combination of deep Hubble imaging and exceptional lensing strength has revealed the greatest numbers of multiply-imaged galaxies available to constrain models of cluster mass distributions. However, even with O(100) images per cluster, the uncertainties associated with the reconstructions are not negligible. The goal of this paper is to show the diversity of model magnification predictions. We examine seven and nine mass models of Abell 2744 and MACS J0416, respectively, submitted to the Mikulski Archive for Space Telescopes for public distribution in 2015 September. The dispersion between model predictions increases from 30 per cent at common low magnifications (μ ˜ 2) to 70 per cent at rare high magnifications (μ ˜ 40). MACS J0416 exhibits smaller dispersions than Abell 2744 for 2 < μ < 10. We show that magnification maps based on different lens inversion techniques typically differ from each other by more than their quoted statistical errors. This suggests that some models underestimate the true uncertainties, which are primarily due to various lensing degeneracies. Though the exact mass sheet degeneracy is broken, its generalized counterpart is not broken at least in Abell 2744. Other local degeneracies are also present in both clusters. Our comparison of models is complementary to the comparison of reconstructions of known synthetic mass distributions. By focusing on observed clusters, we can identify those that are best constrained, and therefore provide the clearest view of the distant Universe.
The epidemiology of personality disorders in the Sao Paulo Megacity general population.
Santana, Geilson Lima; Coelho, Bruno Mendonca; Wang, Yuan-Pang; Chiavegatto Filho, Alexandre Dias Porto; Viana, Maria Carmen; Andrade, Laura Helena
2018-01-01
Most studies on the epidemiology of personality disorders (PDs) have been conducted in high-income countries and may not represent what happens in most part of the world. In the last decades, population growth has been concentrated in low- and middle-income countries, with rapid urbanization, increasing inequalities and escalation of violence. Our aim is to estimate the prevalence of PDs in the Sao Paulo Metropolitan Area, one of the largest megacities of the world. We examined sociodemographic correlates, the influence of urban stressors, the comorbidity with other mental disorders, functional impairment and treatment. A representative household sample of 2,942 adults was interviewed using the WHO-Composite International Diagnostic Interview and the International Personality Disorder Examination-Screening Questionnaire. Diagnoses were multiply imputed, and analyses used multivariable regression. Prevalence estimates were 4.3% (Cluster A), 2.7% (Cluster B), 4.6% (Cluster C) and 6.8% (any PD). Cumulative exposure to violence was associated with all PDs except Cluster A, although urbanicity, migration and neighborhood social deprivation were not significant predictors. Comorbidity was the rule, and all clusters were associated with other mental disorders. Lack of treatment is a reality in Greater Sao Paulo, and this is especially true for PDs. With the exception of Cluster C, non-comorbid PDs remained largely untreated in spite of functional impairment independent of other mental disorders. Personality disorders are prevalent, clinically significant and undertreated, and public health strategies must address the unmet needs of these subjects. Our results may reflect what happens in other developing world megacities, and future studies are expected in other low- and middle-income countries.
The effect of AGN feedback on the X-ray morphologies of clusters: Simulations vs. observations
NASA Astrophysics Data System (ADS)
Chon, Gayoung; Puchwein, Ewald; Böhringer, Hans
2016-07-01
Clusters of galaxies probe the large-scale distribution of matter and are a useful tool to test the cosmological models by constraining cosmic structure growth and the expansion of the Universe. It is the scaling relations between mass observables and the true mass of a cluster through which we obtain the cosmological constraints by comparing to theoretical cluster mass functions. These scaling relations are, however, heavily influenced by cluster morphology. The presence of the slight tension in recent cosmological constraints on Ωm and σ8 based on the CMB and clusters has boosted the interests in looking for possible sources for the discrepancy. Therefore we study here the effect of active galactic nucleus (AGN) feedback as one of the major mechanisms modifying the cluster morphology influencing scaling relations. It is known that AGN feedback injects energies up to 1062 erg into the intracluster medium, controls the heating and cooling of a cluster, and re-distributes cold gas from the centre to outer radii. We have also learned that cluster simulations with AGN feedback can reproduce observed cluster properties, for example, the X-ray luminosity, temperature, and cooling rate at the centre better than without the AGN feedback. In this paper using cosmological hydrodynamical simulations we investigate how the AGN feedback changes the X-ray morphology of the simulated systems, and compare this to the observed Representative XMM-Newton Cluster Structure Survey (REXCESS) clusters. We apply two substructure measures, centre shifts (w) and power ratios (e.g. P3/P0), to characterise the cluster morphology, and find that our simulated clusters are more substructured than the observed clusters based on the values of w and P3/P0. We also show that the degree of this discrepancy is affected by the inclusion of AGN feedback. While the clusters simulated with the AGN feedback are in much better agreement with the REXCESS LX-T relation, they are also more substructured, which increases the tension with observations. When classified as non-relaxed or relaxed according to their w and P3/P0 values, we find that there are no relaxed clusters in the simulations with the AGN feedback. This suggests that not only global cluster properties, like LX and T, and radial profiles should be used to compare and to calibrate simulations with observations, but also substructure measures like centre shifts and power ratios. Finally, we discuss what changes in the simulations might ease the tension with observational constraints on these quantities.
Ybarra, Michele L; Espelage, Dorothy L; Mitchell, Kimberly J
2007-12-01
Previous research in offline environments suggests that there may be an overlap in bullying and sexual harassment perpetration and victimization; however to what extent this may be true for perpetration and victimization of Internet harassment and unwanted sexual solicitation is unknown. The Growing Up with Media survey is a national cross-sectional online survey of 1,588 youth, 10-15 years old, who have used the Internet at least once in the last 6 months. Cluster analysis was conducted with four scales: Internet harassment perpetration, Internet harassment victimization, unwanted sexual solicitation perpetration, and unwanted sexual solicitation victimization. A four-cluster solution was identified: youth with little to no involvement (n = 1326; 81.7%); perpetrator-victims of Internet harassment (n = 205; 14.3%); victims of both Internet harassment and unwanted sexual solicitation (n = 45; 3.1%); and perpetrator-victims of Internet harassment and unwanted sexual solicitation (n = 12; .9%). Involvement in Internet harassment and unwanted sexual solicitation was associated with concurrent reports of psychosocial problems including substance use; involvement in offline victimization and perpetration of relational, physical, and sexual aggression; delinquent peers; a propensity to respond to stimuli with anger; poor emotional bond with caregivers; and poor caregiver monitoring as compared with youth with little to no involvement. This was especially true for perpetrator-victims of Internet harassment and unwanted sexual solicitation. Findings were replicated using a frequency-based definition of involvement, suggesting that cluster analysis is useful in identifying subgroups of youth and can be used to guide frequency-based definitions, which are easier to implement across study samples. The majority of youth are not frequently involved in Internet harassment or unwanted sexual solicitation either as victims or as perpetrators. Among those who are, however, psychosocial problems are apparent. Perpetrator-victims of Internet harassment and unwanted sexual solicitation have emerged as a particularly important group for adolescent health professionals to be aware of, identify, and treat or refer into services immediately.
Clusters and the new economics of competition.
Porter, M E
1998-01-01
Economic geography in an era of global competition poses a paradox. In theory, location should no longer be a source of competitive advantage. Open global markets, rapid transportation, and high-speed communications should allow any company to source any thing from any place at any time. But in practice, Michael Porter demonstrates, location remains central to competition. Today's economic map of the world is characterized by what Porter calls clusters: critical masses in one place of linked industries and institutions--from suppliers to universities to government agencies--that enjoy unusual competitive success in a particular field. The most famous example are found in Silicon Valley and Hollywood, but clusters dot the world's landscape. Porter explains how clusters affect competition in three broad ways: first, by increasing the productivity of companies based in the area; second, by driving the direction and pace of innovation; and third, by stimulating the formation of new businesses within the cluster. Geographic, cultural, and institutional proximity provides companies with special access, closer relationships, better information, powerful incentives, and other advantages that are difficult to tap from a distance. The more complex, knowledge-based, and dynamic the world economy becomes, the more this is true. Competitive advantage lies increasingly in local things--knowledge, relationships, and motivation--that distant rivals cannot replicate. Porter challenges the conventional wisdom about how companies should be configured, how institutions such as universities can contribute to competitive success, and how governments can promote economic development and prosperity.
Rotational and radial velocities of 1.3-2.2 M {sub ☉} red giants in open clusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlberg, Joleen K., E-mail: jcarlberg@dtm.ciw.edu
2014-06-01
This study presents the rotational distribution of red giant (RG) stars in 11 old to intermediate age open clusters. The masses of these stars are all above the Kraft break, so they lose negligible amounts of their birth angular momentum (AM) during the main-sequence (MS) evolution. However, they do span a mass range with quite different AM distributions imparted during formation, with the stars less massive than ∼1.6M {sub ☉} arriving on the MS with lower rotation rates than the more massive stars. The majority of RGs in this study are slow rotators across the entire red giant branch regardlessmore » of mass, supporting the picture that intermediate-mass stars rapidly spin down when they evolve off the MS and develop convection zones capable of driving a magnetic dynamo. Nevertheless, a small fraction of RGs in open clusters show some level of enhanced rotation, and faster rotators are as common in these clusters as in the field RG population. Most of these enhanced rotators appear to be red clump stars, which is also true of the underlying stellar sample, while others are clearly RGs that are above or below the clump. In addition to rotational velocities, the radial velocities (RVs) and membership probabilities of individual stars are also presented. Cluster heliocentric RVs for NGC 6005 and Pismis 18 are reported for the first time.« less
A neutral hydrogen survey of the Hydra 1 cluster
NASA Technical Reports Server (NTRS)
Mcmahon, Pauline; Vangorkom, Jacqueline; Richter, Otto; Ferguson, Henry
1993-01-01
We are undertaking a project to image the entire volume of the Hydra 1 cluster of galaxies in neutral hydrogen using the VLA. This involves making a series of pointings spaced 30 min. (the half power beam width) apart, each observed at three velocity settings in order to span the whole velocity range of the cluster. The purpose of this survey is to determine the true distribution, both in space and velocity, of gas-rich systems and hence, to deduce what effects a dense environment may have on the evolution of these systems. Most surveys of clusters to date have been performed on optically selected samples. However, optically selected samples may provide misleading views of the distribution of gas-rich systems, since many low surface brightness galaxies have an abundance of neutral gas (Bothun et al. 1987, Giovanelli & Haynes 1989). The Hydra project is providing the first unbiased view of the HI distribution in a cluster of galaxies. Our 5 sigma sensitivity is 4.1 x 10(exp 7) solar M/beam, (assuming H(sub 0) = 75 km s(exp -1) Mpc(exp -1)) and our velocity resolution is 42 km s(exp -1). We have a spatial resolution of 45 sec., which means that only the largest galaxies are spatially resolved enough to determine HI disk size. Our coverage is about 50 percent of the central region plus eight other fields centered on bright spirals within about 2 deg. of the center.
A similarity learning approach to content-based image retrieval: application to digital mammography.
El-Naqa, Issam; Yang, Yongyi; Galatsanos, Nikolas P; Nishikawa, Robert M; Wernick, Miles N
2004-10-01
In this paper, we describe an approach to content-based retrieval of medical images from a database, and provide a preliminary demonstration of our approach as applied to retrieval of digital mammograms. Content-based image retrieval (CBIR) refers to the retrieval of images from a database using information derived from the images themselves, rather than solely from accompanying text indices. In the medical-imaging context, the ultimate aim of CBIR is to provide radiologists with a diagnostic aid in the form of a display of relevant past cases, along with proven pathology and other suitable information. CBIR may also be useful as a training tool for medical students and residents. The goal of information retrieval is to recall from a database information that is relevant to the user's query. The most challenging aspect of CBIR is the definition of relevance (similarity), which is used to guide the retrieval machine. In this paper, we pursue a new approach, in which similarity is learned from training examples provided by human observers. Specifically, we explore the use of neural networks and support vector machines to predict the user's notion of similarity. Within this framework we propose using a hierarchal learning approach, which consists of a cascade of a binary classifier and a regression module to optimize retrieval effectiveness and efficiency. We also explore how to incorporate online human interaction to achieve relevance feedback in this learning framework. Our experiments are based on a database consisting of 76 mammograms, all of which contain clustered microcalcifications (MCs). Our goal is to retrieve mammogram images containing similar MC clusters to that in a query. The performance of the retrieval system is evaluated using precision-recall curves computed using a cross-validation procedure. Our experimental results demonstrate that: 1) the learning framework can accurately predict the perceptual similarity reported by human observers, thereby serving as a basis for CBIR; 2) the learning-based framework can significantly outperform a simple distance-based similarity metric; 3) the use of the hierarchical two-stage network can improve retrieval performance; and 4) relevance feedback can be effectively incorporated into this learning framework to achieve improvement in retrieval precision based on online interaction with users; and 5) the retrieved images by the network can have predicting value for the disease condition of the query.
Galaxy Cluster Smashes Distance Record
NASA Astrophysics Data System (ADS)
2009-10-01
he most distant galaxy cluster yet has been discovered by combining data from NASA's Chandra X-ray Observatory and optical and infrared telescopes. The cluster is located about 10.2 billion light years away, and is observed as it was when the Universe was only about a quarter of its present age. The galaxy cluster, known as JKCS041, beats the previous record holder by about a billion light years. Galaxy clusters are the largest gravitationally bound objects in the Universe. Finding such a large structure at this very early epoch can reveal important information about how the Universe evolved at this crucial stage. JKCS041 is found at the cusp of when scientists think galaxy clusters can exist in the early Universe based on how long it should take for them to assemble. Therefore, studying its characteristics - such as composition, mass, and temperature - will reveal more about how the Universe took shape. "This object is close to the distance limit expected for a galaxy cluster," said Stefano Andreon of the National Institute for Astrophysics (INAF) in Milan, Italy. "We don't think gravity can work fast enough to make galaxy clusters much earlier." Distant galaxy clusters are often detected first with optical and infrared observations that reveal their component galaxies dominated by old, red stars. JKCS041 was originally detected in 2006 in a survey from the United Kingdom Infrared Telescope (UKIRT). The distance to the cluster was then determined from optical and infrared observations from UKIRT, the Canada-France-Hawaii telescope in Hawaii and NASA's Spitzer Space Telescope. Infrared observations are important because the optical light from the galaxies at large distances is shifted into infrared wavelengths because of the expansion of the universe. The Chandra data were the final - but crucial - piece of evidence as they showed that JKCS041 was, indeed, a genuine galaxy cluster. The extended X-ray emission seen by Chandra shows that hot gas has been detected between the galaxies, as expected for a true galaxy cluster rather than one that has been caught in the act of forming. Also, without the X-ray observations, the possibility remained that this object could have been a blend of different groups of galaxies along the line of sight, or a filament, a long stream of galaxies and gas, viewed front on. The mass and temperature of the hot gas detected estimated from the Chandra observations rule out both of those alternatives. The extent and shape of the X-ray emission, along with the lack of a central radio source argue against the possibility that the X-ray emission is caused by scattering of cosmic microwave background light by particles emitting radio waves. It is not yet possible, with the detection of just one extremely distant galaxy cluster, to test cosmological models, but searches are underway to find other galaxy clusters at extreme distances. "This discovery is exciting because it is like finding a Tyrannosaurus Rex fossil that is much older than any other known," said co-author Ben Maughan, from the University of Bristol in the United Kingdom. "One fossil might just fit in with our understanding of dinosaurs, but if you found many more, you would have to start rethinking how dinosaurs evolved. The same is true for galaxy clusters and our understanding of cosmology." The previous record holder for a galaxy cluster was 9.2 billion light years away, XMMXCS J2215.9-1738, discovered by ESA's XMM-Newton in 2006. This broke the previous distance record by only about 0.1 billion light years, while JKCS041 surpasses XMMXCS J2215.9 by about ten times that. "What's exciting about this discovery is the astrophysics that can be done with detailed follow-up studies," said Andreon. Among the questions scientists hope to address by further studying JKCS041 are: What is the build-up of elements (such as iron) like in such a young object? Are there signs that the cluster is still forming? Do the temperature and X-ray brightness of such a distant cluster relate to its mass in the same simple way as they do for nearby clusters? The paper describing the results on JKCS041 from Andreon and his colleagues will appear in an upcoming issue of the journal Astronomy and Astrophysics. NASA's Marshall Space Flight Center in Huntsville, Ala., manages the Chandra program for NASA's Science Mission Directorate in Washington, DC. The Smithsonian Astrophysical Observatory controls Chandra's science and flight operations from Cambridge, Mass.
Clustering-based Filtering to Detect Isolated and Intermittent Pulses in Radio Astronomy Data
NASA Astrophysics Data System (ADS)
Wagstaff, Kiri; Tang, B.; Lazio, T. J.; Spolaor, S.
2013-01-01
Radio-emitting neutron stars (pulsars) produce a series of periodic pulses at radio frequencies. Dispersion, caused by propagation through the interstellar medium, delays signals at lower frequencies more than higher frequencies. This well understood effect can be reversed though de-dispersion at the appropriate dispersion measure (DM). The periodic nature of a pulsar provides multiple samples of signals at the same DM, increasing the reliability of any candidate detection. However, existing methods for pulsar detection are ineffective for many pulse-emitting phenomena now being discovered. Sources exhibit a wide range of pulse repetition rates, from highly regular canonical pulsars to intermittent and nulling pulsars to rotating radio transients (RRATs) that may emit only a few pulses per hour. Other source types may emit only a few pulses, or even only a single pulse. We seek to broaden the scope of radio signal analysis to enable the detection of isolated and intermittent pulses. Without a requirement that detected sources be periodic, we find that a typical de-dispersion search yields results that are often dominated by spurious detections from radio frequency interference (RFI). These occur across the DM range, so filtering out DM-0 signals is insufficient. We employ DBSCAN data clustering to identify groups within the de-dispersion results, using information for each candidate about time, DM, SNR, and pulse width. DBSCAN is a density-based clustering algorithm that offers two advantages over other clustering methods: 1) the number of clusters need not to be specified, and 2) there is no model of expected cluster shape (such as the Gaussian assumption behind EM clustering). Each data cluster can be selectively masked or investigated to facilitate the process of sifting through hundreds of thousands of detections to focus on those of true interest. Using data obtained by the Byrd Green Bank Telescope (GBT), we show how this approach can help separate RFI from difficult to find single and intermittent pulses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bayram, Ercan; Linehan, John C.; Fulton, John L.
Determining the kinetically dominant catalyst in a given catalytic system is a forefront topic in catalysis. The [RhCp*Cl₂]₂ (Cp* =[η⁵-C₅(CH₃)₅]) system pioneered by Maitlis and co-workers is a classic precatalyst system from which homogeneous mononuclear Rh₁, subnanometer Rh₄ cluster, and heterogeneous polymetallic Rh(0) n nanoparticle have all arisen as viable candidates for the true hydrogenation catalyst, depending on the precise substrate, H₂ pressure, temperature, and catalyst concentration conditions. Addressed herein is the question of whether the prior assignment of homogeneous, mononuclear Rh₁Cp*-based catalysis is correct, or are trace Rh₄ subnanometer clusters or possibly Rh(0) n nanoparticles the dominant, actualmore » cyclohexene hydrogenation catalyst at 22 °C and 2.7 atm initial H₂ pressure? The observation herein of Rh₄ species by in operando-X-ray absorption fine structure (XAFS) spectroscopy, at the only slightly more vigorous conditions of 26 °C and 8.3 atm H₂ pressure, and the confirmation of Rh₄ clusters by ex situ mass spectroscopy raises the question of the dominant, room temperature, and mild pressure cyclohexene hydrogenation catalyst derived from the classic [RhCp*Cl₂]₂ precatalyst pioneered by Maitlis and co-workers. Ten lines of evidence are provided herein to address the nature of the true room temperature and mild pressure cyclohexene hydrogenation catalyst derived from [RhCp*Cl₂]₂. Especially significant among those experiments are quantitative catalyst poisoning experiments, in the present case using 1,10-phenanthroline. Those poisoning studies allow one to distinguish mononuclear Rh₁, subnanometer Rh₄ cluster, and Rh(0) n nanoparticle catalysis hypotheses. The evidence obtained provides a compelling case for a mononuclear, Rh₁Cp*-based cyclohexene hydrogenation catalyst at 22 °C and 2.7 atm H₂ pressure. The resultant methodology, especially the quantitative catalyst poisoning experiments in combination with in operando spectroscopy, is expected to be more broadly applicable to the study of other systems and the “what is the true catalyst?” question. The authors would like to thank Finke Group members and Prof. Saim Ö zkar for their valuable input as this work was proceeding. This work was supported at Colorado State University by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences, vial DOE Grant SE-FG402-03ER15453. The work at PNNL was also supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geo-sciences & Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for the DOE by Battelle. XSD/PNC facilities at the Advanced Photon Source and research at these facilities are supported by the U.S. Department of Energy, Basic Energy Sciences; a Major Resources Support Grant from NSERC; the University of Washington; the Canadian Light Source; and the Advanced Photon Source. Use of the Advanced Photon Source, an Office of Science User Facility operated for the U.S. Department of Energy Office of Science by Argonne National Laboratory was supported by the U.S. DOE under Contract No. DE-AC02- 06CH11357.« less
Formation of Compact Ellipticals in the merging star cluster scenario
NASA Astrophysics Data System (ADS)
Urrutia Zapata, Fernanda Cecilia; Theory and star formation group
2018-01-01
In the last years, extended old stellar clusters have been observed. They are like globular clusters (GCs) but with larger sizes(a limit of Re=10 pc is currently seen as reasonable). These extended objects (EOs) cover a huge range of mass. Objects at the low mass end with masses comparable to normal globular clusters are called extended clusters or faint fuzzies Larsen & Brodie (2000) and objects at the high-mass end are called ultra compact dwarf galaxies (UCDs). Ultra compact dwarf galaxies are compact object with luminositys above the brigtest known GCs. UCDs are more compact than typical dwarf galaxies but with comparable luminosities. Usually, a lower mass limit of 2 × 10^6 Solar masses is applied.Fellhauer & Kroupa (2002a,b) demostrated that object like ECs, FFs and UCDs can be the remnants of the merger of star clusters complexes, this scenario is called the Merging Star Cluster Scenario. Amore concise study was performed by Bruens et al. (2009, 2011).Our work tries to explain the formation of compact elliptical(cE). These objects are a comparatively rare class of spheroidal galaxies, possessing very small Re and high central surface brightnesses (Faber 1973). cEs have the same parameters as extended objects but they are slightly larger than 100 pc and the luminosities are in the range of -11 to -12 Mag.The standard formation sceanrio of these systems proposes a galaxy origin. CEs are the result of tidal stripping and truncation of nucleated larger systems. Or they could be a natural extension of the class of elliptical galaxies to lower luminosities and smaller sizes.We want to propose a completely new formation scenario for cEs. In our project we try to model cEs in a similar way that UCDs using the merging star cluster scenario extended to much higher masses and sizes. We think that in the early Universe we might have produced sufficiently strong star bursts to form cluster complexes which merge into cEs. So far it is observationally unknown if cEs are dark matter dominated objects. If our scenario is true, then they would be dark matter free very extended and massive "star clusters".
NASA Astrophysics Data System (ADS)
Martínez-Galarza, Rafael; Protopapas, Pavlos; Smith, Howard A.; Morales, Esteban
2018-01-01
From an observational point of view, the early life of massive stars is difficult to understand partly because star formation occurs in crowded clusters where individual stars often appear blended together in the beams of infrared telescopes. This renders the characterization of the physical properties of young embedded clusters via spectral energy distribution (SED) fitting a challenging task. Of particular relevance for the testing of star formation models is the question of whether the claimed universality of the IMF (references) is reflected in an equally universal integrated galactic initial mass function (IGIMF) of stars. In other words, is the set of all stellar masses in the galaxy sampled from a single universal IMF, or does the distribution of masses depend on the environment, making the IGIMF different from the canonical IMF? If the latter is true, how different are the two? We present a infrared SED analysis of ~70 Spitzer-selected, low mass ($<100~\\rm{M}_{\\odot}$), galactic blended clusters. For all of the clusters we obtain the most probable individual SED of each member and derive their physical properties, effectively deblending the confused emission from individual YSOs. Our algorithm incorporates a combined probabilistic model of the blended SEDs and the unresolved images in the long-wavelength end. We find that our results are compatible with competitive accretion in the central regions of young clusters, with the most massive stars forming early on in the process and less massive stars forming about 1Myr later. We also find evidence for a relationship between the total stellar mass of the cluster and the mass of the most massive member that favors optimal sampling in the cluster and disfavors random sampling for the canonical IMF, implying that star formation is self-regulated, and that the mass of the most massive star in a cluster depends on the available resources. The method presented here is easily adapted to future observations of clustered regions of star formation with JWST and other high resolution facilities.
Hubble Revisits a Globular Cluster’s Age
2014-08-13
This new NASA/ESA Hubble Space Telescope image shows the globular cluster IC 4499. Globular clusters are big balls of old stars that orbit around their host galaxy. It has long been believed that all the stars within a globular cluster form at the about same time, a property which can be used to determine the cluster's age. For more massive globulars however, detailed observations have shown that this is not entirely true — there is evidence that they instead consist of multiple populations of stars born at different times. One of the driving forces behind this behavior is thought to be gravity: more massive globulars manage to grab more gas and dust, which can then be transformed into new stars. IC 4499 is a somewhat special case. Its mass lies somewhere between low-mass globulars, which show a single generation build-up, and the more complex and massive globulars which can contain more than one generation of stars. By studying objects like IC 4499 astronomers can therefore explore how mass affects a cluster's contents. Astronomers found no sign of multiple generations of stars in IC 4499 — supporting the idea that less massive clusters in general only consist of a single stellar generation. Hubble observations of IC 4499 have also helped to pinpoint the cluster's age: observations of this cluster from the 1990s suggested a puzzlingly young age when compared to other globular clusters within the Milky Way. However, since those first estimates new Hubble data have been obtained and it has been found to be much more likely that IC 4499 is actually roughly the same age as other Milky Way clusters at approximately 12 billion years old. Credit: ESA and NASA NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
NASA Astrophysics Data System (ADS)
Hesser, J. E.; Stetson, P. B.; McClure, R. D.; van den Bergh, S.; Bolte, M.; Harris, W. E.; van den Berg, D. A.; Bell, R. A.; Fahlman, G. G.; Richer, H. B.; Bond, H. E.
1997-12-01
Last year we presented evidence from HST photometry of the low-metallicity cluster NGC 2419 (M_V = -9.5, R_⊙ ~ 90 kpc, [Fe/H] = -2.2) that globular cluster formation began at essentially the same time throughout a region of the Galactic halo now almost 200 kpc in diameter (Harris et al. 1997 AJ 114, 1030). We now turn to the time spread of halo formation, with the ultimate aim of addressing the relative roles of mergers over the first 4 or more Gyrs (Searle & Zinn 1978, ApJ, 225, 357; Lee, Demarque & Zinn 1994 ApJ, 423, 248) versus models favoring a rapid collapse (Eggen, Lynden-Bell & Sandage 1962, ApJ, 236, 748; Stetson, VandenBerg & Bolte 1996, PASP, 108, 560), or some combination of those and other processes. We provide the first reliable measurements from the giant branch through the main-sequence turnoffs of red-horizontal-branch clusters in the outer halo, which are frequently postulated to be younger than most other globular clusters. From WFPC2 F555W (`V') and F814W (`I') photometry for Pal 3 (M_V = -5.2, R_⊙ ~ 87 kpc), Pal 4 (M_V = -5.8, R_⊙ ~ 98 kpc), and Eridanus (M_V = -4.8, R_⊙ ~ 78 kpc), all with [Fe/H] ~ -1.5, we estimate their relative ages by making differential comparisons among them and with respect to inner-halo objects of, presumably, comparable chemical compositions. It seems likely at this stage of our analysis that (a) the three clusters are the same age to our measurement precision of ~ 1 Gyr, and, (b) the CMDs of all three outer halo clusters differ from those of M 3 and M 5 (our template clusters of similar metallicity), in the sense that the outer halo clusters are younger by ~ 3 Gyr, or they are ~ 0.5 dex more metal-rich than currently thought. Large uncertainties in chemical compositions (He, [alpha /Fe], [CNO/Fe]) for outer halo and template clusters alike mask the true interpretation.
Matsumoto, Lumine; Yamamoto, Tomotaka; Higashihara, Mana; Sugimoto, Izumi; Kowa, Hisatomo; Shibahara, Junji; Nakamura, Koichiro; Shimizu, Jun; Ugawa, Yoshikazu; Goto, Jun; Dalmau, Josep; Tsuji, Shoji
2007-04-15
We report a 40-year-old man with severe hypokinesis as paraneoplastic manifestation of a microscopic "carcinoma in situ" of the testis. The young age of the patient, along with progressive neurologic deterioration, detection of anti-Ma2 antibodies, and ultrasound findings of bilateral microcalcifications, led to bilateral orchiectomy, revealing the tumor in both testes. After orchiectomy, neurological symptoms stabilized, but the patient eventually died of systemic complications caused by his severe neurological deficits. Anti-Ma2 paraneoplastic encephalitis should be considered in patients with severe hypokinesis, and intensive investigation and aggressive approach to treatment is encouraged to prevent progression of the neurological deficits.
Matsumoto, Lumine; Yamamoto, Tomotaka; Higashihara, Mana; Sugimoto, Izumi; Kowa, Hisatomo; Shibahara, Junji; Nakamura, Koichiro; Shimizu, Jun; Ugawa, Yoshikazu; Goto, Jun; Dalmau, Josep; Tsuji, Shoji
2007-01-01
We report a 40-year-old man with severe hypokinesis as paraneoplastic manifestation of a microscopic “carcinoma in situ” of the testis. The young age of the patient, along with progressive neurologic deterioration, detection of anti-Ma2 antibodies, and ultrasound findings of bilateral microcalcifications, led to bilateral orchiectomy, revealing the tumor in both testes. After orchiectomy, neurological symptoms stabilized, but the patient eventually died of systemic complications caused by his severe neurological deficits. Anti-Ma2 paraneoplastic encephalitis should be considered in patients with severe hypokinesis, and intensive investigation and aggressive approach to treatment is encouraged to prevent progression of the neurological deficits. PMID:17269131
Use of the Hotelling observer to optimize image reconstruction in digital breast tomosynthesis
Sánchez, Adrian A.; Sidky, Emil Y.; Pan, Xiaochuan
2015-01-01
Abstract. We propose an implementation of the Hotelling observer that can be applied to the optimization of linear image reconstruction algorithms in digital breast tomosynthesis. The method is based on considering information within a specific region of interest, and it is applied to the optimization of algorithms for detectability of microcalcifications. Several linear algorithms are considered: simple back-projection, filtered back-projection, back-projection filtration, and Λ-tomography. The optimized algorithms are then evaluated through the reconstruction of phantom data. The method appears robust across algorithms and parameters and leads to the generation of algorithm implementations which subjectively appear optimized for the task of interest. PMID:26702408
Construction of mammography phantoms with a 3D printer and tested with a TIMEPIX system
NASA Astrophysics Data System (ADS)
Calderón-García, J. S.; Roque, G. A.; Ávila, C. A.
2017-11-01
We present a new mammography phantom made of hydroxyapatite crystals with different sizes and shapes, to emulate anthropomorphic microcalcifications, which we locate at different depths of a PMMA embedding material. The aim of the phantom presented is to address some issues of the standard commercial ones that are being used for comparing 3D vs 2D mammography systems. We present X-ray images, taken under the same conditions, for both a commercial phantom and the new proposed phantom. We compare signal to noise ratios (SNR) obtained for both cases. This phantom has been constructed to be easily assembled within different configurations to emulate modified features that might be of medical interest.
Valli, Maria Beatrice; Meschi, Silvia; Selleri, Marina; Zaccaro, Paola; Ippolito, Giuseppe; Capobianchi, Maria Rosaria; Menzo, Stefano
2010-01-01
Influenza A( H1N1)v has spread rapidly in all parts of the globe in 2009 as a true pandemic, although fortunately a clinically mild one. The relevant evolutionary steps for the new virus to adapt to human populations occurred very early during the pandemic, before the end of April. Of the several resulting clades or clusters, clade 7 appeared later and proved more successful, substituting all other early clades before the bulk of the worldwide infections occurred. PMID:20228856
On the Unusually High Temperature of the Cluster of Galaxies 1E 0657-56
NASA Technical Reports Server (NTRS)
Yaqoob, Tahir
1999-01-01
A recent X-ray observation of the cluster 1E 0657-56 (z = 0.296) with ASC,4 implied an unusually high temperature of approx. 17 keV. Such a high temperature would make it the hottest known cluster and severely constrain cosmological models since, in a Universe with critical density (Omega = 1) the probability of observing such a cluster is only approx. 4 x 10(exp -5). Here we test the robustness of this observational result since it has such important implications. We analysed the data using a variety of different data analysis methods and spectral analysis assumptions and find a temperature of approx. 11 - 12 keV in all cases, except for one class of spectral fits. These are fits in which the absorbing column density is fixed at the Galactic value. Using simulated data for a 12 keV cluster, we show that a high temperature of approx. 17 keV is artificially obtained if the true spectrum has a stronger low-energy cut-off than that for Galactic absorption only. The apparent extra absorption may be astrophysical in origin, (either intrinsic or line-of-sight), or it may be a problem with the low-energy CCD efficiency. Although significantly lower than previous measurements, this temperature of kT approx. 11 - 12 keV is still relatively high since only a few clusters have been found to have temperatures higher than 10 keV and the data therefore still present some difficulty for an Omega = 1 Universe. Our results will also be useful to anyone who wants to estimate the systematic errors involved in different methods of background subtraction of ASCA data for sources with similar signal-to-noise to that of the IE 0657-56 data reported here.
Enabling Diverse Software Stacks on Supercomputers using High Performance Virtual Clusters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Younge, Andrew J.; Pedretti, Kevin; Grant, Ryan
While large-scale simulations have been the hallmark of the High Performance Computing (HPC) community for decades, Large Scale Data Analytics (LSDA) workloads are gaining attention within the scientific community not only as a processing component to large HPC simulations, but also as standalone scientific tools for knowledge discovery. With the path towards Exascale, new HPC runtime systems are also emerging in a way that differs from classical distributed com- puting models. However, system software for such capabilities on the latest extreme-scale DOE supercomputing needs to be enhanced to more appropriately support these types of emerging soft- ware ecosystems. In thismore » paper, we propose the use of Virtual Clusters on advanced supercomputing resources to enable systems to support not only HPC workloads, but also emerging big data stacks. Specifi- cally, we have deployed the KVM hypervisor within Cray's Compute Node Linux on a XC-series supercomputer testbed. We also use libvirt and QEMU to manage and provision VMs directly on compute nodes, leveraging Ethernet-over-Aries network emulation. To our knowledge, this is the first known use of KVM on a true MPP supercomputer. We investigate the overhead our solution using HPC benchmarks, both evaluating single-node performance as well as weak scaling of a 32-node virtual cluster. Overall, we find single node performance of our solution using KVM on a Cray is very efficient with near-native performance. However overhead increases by up to 20% as virtual cluster size increases, due to limitations of the Ethernet-over-Aries bridged network. Furthermore, we deploy Apache Spark with large data analysis workloads in a Virtual Cluster, ef- fectively demonstrating how diverse software ecosystems can be supported by High Performance Virtual Clusters.« less
Pep2Path: automated mass spectrometry-guided genome mining of peptidic natural products.
Medema, Marnix H; Paalvast, Yared; Nguyen, Don D; Melnik, Alexey; Dorrestein, Pieter C; Takano, Eriko; Breitling, Rainer
2014-09-01
Nonribosomally and ribosomally synthesized bioactive peptides constitute a source of molecules of great biomedical importance, including antibiotics such as penicillin, immunosuppressants such as cyclosporine, and cytostatics such as bleomycin. Recently, an innovative mass-spectrometry-based strategy, peptidogenomics, has been pioneered to effectively mine microbial strains for novel peptidic metabolites. Even though mass-spectrometric peptide detection can be performed quite fast, true high-throughput natural product discovery approaches have still been limited by the inability to rapidly match the identified tandem mass spectra to the gene clusters responsible for the biosynthesis of the corresponding compounds. With Pep2Path, we introduce a software package to fully automate the peptidogenomics approach through the rapid Bayesian probabilistic matching of mass spectra to their corresponding biosynthetic gene clusters. Detailed benchmarking of the method shows that the approach is powerful enough to correctly identify gene clusters even in data sets that consist of hundreds of genomes, which also makes it possible to match compounds from unsequenced organisms to closely related biosynthetic gene clusters in other genomes. Applying Pep2Path to a data set of compounds without known biosynthesis routes, we were able to identify candidate gene clusters for the biosynthesis of five important compounds. Notably, one of these clusters was detected in a genome from a different subphylum of Proteobacteria than that in which the molecule had first been identified. All in all, our approach paves the way towards high-throughput discovery of novel peptidic natural products. Pep2Path is freely available from http://pep2path.sourceforge.net/, implemented in Python, licensed under the GNU General Public License v3 and supported on MS Windows, Linux and Mac OS X.
Sims, Lynn M; Igarashi, Robert Y
2012-08-15
Ribosomal function is dependent on multiple proteins. The ABCE1 ATPase, a unique ABC superfamily member that bears two Fe₄S₄ clusters, is crucial for ribosomal biogenesis and recycling. Here, the ATPase activity of the Pyrococcus abyssi ABCE1 (PabABCE1) was studied using both apo- (without reconstituted Fe-S clusters) and holo- (with full complement of Fe-S clusters reconstituted post-purification) forms, and is shown to be jointly regulated by the status of Fe-S clusters and Mg²⁺. Typically ATPases require Mg²⁺, as is true for PabABCE1, but Mg²⁺ also acts as a negative allosteric effector that modulates ATP affinity of PabABCE1. Physiological [Mg²⁺] inhibits the PabABCE1 ATPase (K(i) of ∼1 μM) for both apo- and holo-PabABCE1. Comparative kinetic analysis of Mg²⁺ inhibition shows differences in degree of allosteric regulation between the apo- and holo-PabABCE1 where the apparent ATP K(m) of apo-PabABCE1 increases >30-fold from ∼30 μM to over 1 mM with M²⁺. This effect would significantly convert the ATPase activity of PabABCE1 from being independent of cellular energy charge (φ) to being dependent on φ with cellular [Mg²⁺]. These findings uncover intricate overlapping effects by both [Mg²⁺] and the status of Fe-S clusters that regulate ABCE1's ATPase activity with implications to ribosomal function. Copyright © 2012 Elsevier Inc. All rights reserved.
Conformal doping of topographic silicon structures using a radial line slot antenna plasma source
NASA Astrophysics Data System (ADS)
Ueda, Hirokazu; Ventzek, Peter L. G.; Oka, Masahiro; Horigome, Masahiro; Kobayashi, Yuuki; Sugimoto, Yasuhiro; Nozawa, Toshihisa; Kawakami, Satoru
2014-06-01
Fin extension doping for 10 nm front end of line technology requires ultra-shallow high dose conformal doping. In this paper, we demonstrate a new radial line slot antenna plasma source based doping process that meets these requirements. Critical to reaching true conformality while maintaining fin integrity is that the ion energy be low and controllable, while the dose absorption is self-limited. The saturated dopant later is rendered conformal by concurrent amorphization and dopant containing capping layer deposition followed by stabilization anneal. Dopant segregation assists in driving dopants from the capping layer into the sub silicon surface. Very high resolution transmission electron microscopy-Energy Dispersive X-ray spectroscopy, used to prove true conformality, was achieved. We demonstrate these results using an n-type arsenic based plasma doping process on 10 to 40 nm high aspect ratio fins structures. The results are discussed in terms of the different types of clusters that form during the plasma doping process.
NASA Astrophysics Data System (ADS)
Xiaoyu, Lai; Renxin, Xu
2017-06-01
The nature of pulsar-like compact stars is essentially a central question of the fundamental strong interaction (explained in quantum chromo-dynamics) at low energy scale, the solution of which still remains a challenge though tremendous efforts have been tried. This kind of compact objects could actually be strange quark stars if strange quark matter in bulk may constitute the true ground state of the strong-interaction matter rather than 56Fe (the so-called Witten’s conjecture). From astrophysical points of view, however, it is proposed that strange cluster matter could be absolutely stable and thus those compact stars could be strange cluster stars in fact. This proposal could be regarded as a general Witten’s conjecture: strange matter in bulk could be absolutely stable, in which quarks are either free (for strange quark matter) or localized (for strange cluster matter). Strange cluster with three-light-flavor symmetry is renamed strangeon, being coined by combining “strange nucleon” for the sake of simplicity. A strangeon star can then be thought as a 3-flavored gigantic nucleus, and strangeons are its constituent as an analogy of nucleons which are the constituent of a normal (micro) nucleus. The observational consequences of strangeon stars show that different manifestations of pulsarlike compact stars could be understood in the regime of strangeon stars, and we are expecting more evidence for strangeon star by advanced facilities (e.g., FAST, SKA, and eXTP).
NASA Astrophysics Data System (ADS)
Wilkinson, Aaron; Almaini, Omar; Chen, Chian-Chou; Smail, Ian; Arumugam, Vinodiran; Blain, Andrew; Chapin, Edward L.; Chapman, Scott C.; Conselice, Christopher J.; Cowley, William I.; Dunlop, James S.; Farrah, Duncan; Geach, James; Hartley, William G.; Ivison, Rob J.; Maltby, David T.; Michałowski, Michał J.; Mortlock, Alice; Scott, Douglas; Simpson, Chris; Simpson, James M.; van der Werf, Paul; Wild, Vivienne
2017-01-01
Submillimetre galaxies (SMGs) are among the most luminous dusty galaxies in the Universe, but their true nature remains unclear; are SMGs the progenitors of the massive elliptical galaxies we see in the local Universe, or are they just a short-lived phase among more typical star-forming galaxies? To explore this problem further, we investigate the clustering of SMGs identified in the SCUBA-2 Cosmology Legacy Survey. We use a catalogue of submillimetre (850 μm) source identifications derived using a combination of radio counterparts and colour/infrared selection to analyse a sample of 610 SMG counterparts in the United Kingdom Infrared Telescope (UKIRT) Infrared Deep Survey (UKIDSS) Ultra Deep Survey (UDS), making this the largest high-redshift sample of these galaxies to date. Using angular cross-correlation techniques, we estimate the halo masses for this large sample of SMGs and compare them with passive and star-forming galaxies selected in the same field. We find that SMGs, on average, occupy high-mass dark matter haloes (Mhalo > 1013 M⊙) at redshifts z > 2.5, consistent with being the progenitors of massive quiescent galaxies in present-day galaxy clusters. We also find evidence of downsizing, in which SMG activity shifts to lower mass haloes at lower redshifts. In terms of their clustering and halo masses, SMGs appear to be consistent with other star-forming galaxies at a given redshift.
Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner
NASA Astrophysics Data System (ADS)
Kis, S. A.; Emri, M.; Opposits, G.; Bükki, T.; Valastyán, I.; Hegyesi, Gy.; Imrek, J.; Kalinka, G.; Molnár, J.; Novák, D.; Végh, J.; Kerek, A.; Trón, L.; Balkay, L.
2007-02-01
In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
Clinical significance of mycobacterial genotyping in Mycobacterium avium lung disease in Korea.
Kim, S-Y; Lee, S-T; Jeong, B-H; Jeon, K; Kim, J-W; Shin, S J; Koh, W-J
2012-10-01
A recent study in Japan found that mycobacterial genotyping was associated with disease progression and susceptibility to certain drugs in Mycobacterium avium lung disease. However, it is not known whether this association is true in other populations. To investigate the association between mycobacterial genotype, clinical characteristics and the progression of M. avium lung disease in Korean patients. A total of 102 M. avium clinical isolates were genotyped using M. avium tandem repeats-variable number of tandem repeats (MATR-VNTR). MATR-VNTR typing demonstrated a high discriminatory power and genetic diversity for molecular epidemiological studies of M. avium. In the phylogenetic tree, the M. avium clinical isolates were divided into three major clusters: A, B and C. Cluster A was observed most frequently (64/102, 63%), whereas cluster C was found in a minor proportion of the isolates (8/102, 8%). However, there was no association between the clinical characteristics, disease progression and drug susceptibility and the phylogenetic tree based on VNTR genotyping. MATR-VNTR genotyping may be useful for epidemiological studies of M. avium lung disease; however, no association was found between the specific VNTR genotypes of M. avium and the clinical characteristics of Korean patients.
Mechanisms for the clustering of inertial particles in the inertial range of isotropic turbulence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bragg, Andrew D.; Ireland, Peter J.; Collins, Lance R.
2015-08-27
In this study, we consider the physical mechanism for the clustering of inertial particles in the inertial range of isotropic turbulence. We analyze the exact, but unclosed, equation governing the radial distribution function (RDF) and compare the mechanisms it describes for clustering in the dissipation and inertial ranges. We demonstrate that in the limit St r <<1, where St r is the Stokes number based on the eddy turnover time scale at separation r, the clustering in the inertial range can be understood to be due to the preferential sampling of the coarse-grained fluid velocity gradient tensor at that scale.more » When St r≳O(1) this mechanism gives way to a nonlocal clustering mechanism. These findings reveal that the clustering mechanisms in the inertial range are analogous to the mechanisms that we identified for the dissipation regime. Further, we discuss the similarities and differences between the clustering mechanisms we identify in the inertial range and the “sweep-stick” mechanism developed by Coleman and Vassilicos. We show that the idea that initial particles are swept along with acceleration stagnation points is only approximately true because there always exists a finite difference between the velocity of the acceleration stagnation points and the local fluid velocity. This relative velocity is sufficient to allow particles to traverse the average distance between the stagnation points within the correlation time scale of the acceleration field. We also show that the stick part of the mechanism is only valid for St r<<1 in the inertial range. We emphasize that our clustering mechanism provides the more fundamental explanation since it, unlike the sweep-stick mechanism, is able to explain clustering in arbitrary spatially correlated velocity fields. We then consider the closed, model equation for the RDF given in Zaichik and Alipchenkov and use this, together with the results from our analysis, to predict the analytic form of the RDF in the inertial range for St r<<1, which, unlike that in the dissipation range, is not scale invariant. Finally, the results are in good agreement with direct numerical simulations, provided the separations are well within the inertial range.« less
Crescenti, Anna; Puiggròs, Francesc; Colomé, Arnau; Poch, Josep Antón; Caimari, Antoni; Bas, Josep Maria; Boqué, Noemí; Arola, Lluís
2015-12-01
To determine the effect of a botanical formulation of Herniaria glabra, Agropyron repens, Equisetum arvense, and Sambucus nigra as a preventive agent in an experimentally induced nefrolithiasis model in rats. Six groups of six Wistar male rats each were induced for nefrolithiasis by treatment with 0.75% ethylene glycol (EG) and 1% ammonium chloride for three days and then EG only for 15 days. One group was treated with placebo (control group) and the other groups (treated groups) were treated with 30 mg/Kg, 60 mg/Kg, 125 mg/Kg, 250 mg/Kg and 500 mg/Kg of the plant extract formulation (PEF). 24-h urine and water samples were collected one day before EG administration and at 7, 13 and 18 days to determine diuresis, crystalluria and urine biochemistry. The kidneys were removed for histological analysis. The phytochemical characterization of PEF and each of its component plant extracts was performed using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry. Animals treated with 125 mg/Kg of the PEF had statistically significantly lower calcium oxalate crystals deposits content compared to the control group. All PEF doses statistically significantly decreased the number of microcalcifications compared to the control group. Furthermore, the number of kidneys affected by subcapsular fibrosis was statistically significantly higher in control group than in treated groups with the PEF. The diuresis of the 125 mg/Kg and 500 mg/Kg PEF-treated groups was statistically significantly higher than that of the control group. A phytochemical analysis demonstrated the presence of flavonoids, dicarboxylic acids and saponins. Treatment with PEF prevents deposits of calcium oxalate crystals formation and of microcalcifications in the kidney, and reduces the risk of fibrosis subcapsular. 125 mg/Kg of PEF is the dose that has a greater effect on the studied parameters.
Uzoaru, Ikechukwu; Morgan, Bradley R; Liu, Zheng G; Bellafiore, Frank J; Gaudier, Farah S; Lo, Jeanne V; Pakzad, Kourosh
2012-10-01
Flat epithelial atypia (FEA) of the breast have a tendency to calcify and, as such, are becoming increasingly detected by mammography. There is no consensus yet on whether to excise these lesions or not after diagnosis on core needle biopsies (CNB). We reviewed 3,948 cases of breast CNB between June 2004 and June 2009 correlating histomorphologic, radiological, and clinical features. There were 3.7 % (145/3,948) pure FEA and 1.5 % (58/3,948) concomitant FEA and atypical ductal hyperplasia (ADH). In the pure FEA population, 46.2 % (67/145) had microcalcifications on mammography with 65.5 % (95/145) of patients undergoing subsequent excisional biopsies with the following findings: benign 20 % (19/95), ADH 37.9 % (36/95), ductal carcinoma in situ (DCIS) 1.1 % (1/95), and DCIS and invasive ductal carcinoma (IDC) 2.1 % (2/95). In the concomitant FEA and ADH group, 86.2 % (50/58) patients had microcalcifications on radiograph with 74.1 % (43/58) of patients undergoing subsequent excisions with: benign 23.3 % (10/43), DCIS 9.3 % (4/43), DCIS and IDC 4.7 % (2/43), DCIS + lobular carcinoma in situ + invasive lobular carcinoma 2.3 % (1/43), and tubular carcinoma 2.3 % (1/43). The incidence of carcinoma in the FEA + ADH group is 18.6 % (8/43) and 3.2 % (3/95) for the pure FEA group. This difference is statistically significant (p = 0.0016). The relative risk of carcinoma in the ADH + FEA group versus the pure FEA group is 6.4773, with 95 % CI of 1.8432 and 22.76 24. Five-year mean follow-up in the unexcised pure FEA did not show any malignancies. These findings suggest that pure FEA has a very low association with carcinoma, and these patients may benefit from close clinical and mammographic follow-up while the combined pure FEA and ADH cases may be re-excised.
Shirazinodeh, Alireza; Noubari, Hossein Ahmadi; Rabbani, Hossein; Dehnavi, Alireza Mehri
2015-01-01
Recent studies on wavelet transform and fractal modeling applied on mammograms for the detection of cancerous tissues indicate that microcalcifications and masses can be utilized for the study of the morphology and diagnosis of cancerous cases. It is shown that the use of fractal modeling, as applied to a given image, can clearly discern cancerous zones from noncancerous areas. In this paper, for fractal modeling, the original image is first segmented into appropriate fractal boxes followed by identifying the fractal dimension of each windowed section using a computationally efficient two-dimensional box-counting algorithm. Furthermore, using appropriate wavelet sub-bands and image Reconstruction based on modified wavelet coefficients, it is shown that it is possible to arrive at enhanced features for detection of cancerous zones. In this paper, we have attempted to benefit from the advantages of both fractals and wavelets by introducing a new algorithm. By using a new algorithm named F1W2, the original image is first segmented into appropriate fractal boxes, and the fractal dimension of each windowed section is extracted. Following from that, by applying a maximum level threshold on fractal dimensions matrix, the best-segmented boxes are selected. In the next step, the segmented Cancerous zones which are candidates are then decomposed by utilizing standard orthogonal wavelet transform and db2 wavelet in three different resolution levels, and after nullifying wavelet coefficients of the image at the first scale and low frequency band of the third scale, the modified reconstructed image is successfully utilized for detection of breast cancer regions by applying an appropriate threshold. For detection of cancerous zones, our simulations indicate the accuracy of 90.9% for masses and 88.99% for microcalcifications detection results using the F1W2 method. For classification of detected mictocalcification into benign and malignant cases, eight features are identified and utilized in radial basis function neural network. Our simulation results indicate the accuracy of 92% classification using F1W2 method.
A comparison study of image features between FFDM and film mammogram images
Jing, Hao; Yang, Yongyi; Wernick, Miles N.; Yarusso, Laura M.; Nishikawa, Robert M.
2012-01-01
Purpose: This work is to provide a direct, quantitative comparison of image features measured by film and full-field digital mammography (FFDM). The purpose is to investigate whether there is any systematic difference between film and FFDM in terms of quantitative image features and their influence on the performance of a computer-aided diagnosis (CAD) system. Methods: The authors make use of a set of matched film-FFDM image pairs acquired from cadaver breast specimens with simulated microcalcifications consisting of bone and teeth fragments using both a GE digital mammography system and a screen-film system. To quantify the image features, the authors consider a set of 12 textural features of lesion regions and six image features of individual microcalcifications (MCs). The authors first conduct a direct comparison on these quantitative features extracted from film and FFDM images. The authors then study the performance of a CAD classifier for discriminating between MCs and false positives (FPs) when the classifier is trained on images of different types (film, FFDM, or both). Results: For all the features considered, the quantitative results show a high degree of correlation between features extracted from film and FFDM, with the correlation coefficients ranging from 0.7326 to 0.9602 for the different features. Based on a Fisher sign rank test, there was no significant difference observed between the features extracted from film and those from FFDM. For both MC detection and discrimination of FPs from MCs, FFDM had a slight but statistically significant advantage in performance; however, when the classifiers were trained on different types of images (acquired with FFDM or SFM) for discriminating MCs from FPs, there was little difference. Conclusions: The results indicate good agreement between film and FFDM in quantitative image features. While FFDM images provide better detection performance in MCs, FFDM and film images may be interchangeable for the purposes of training CAD algorithms, and a single CAD algorithm may be applied to either type of images. PMID:22830771
Habitability in different Milky Way stellar environments: a stellar interaction dynamical approach.
Jiménez-Torres, Juan J; Pichardo, Bárbara; Lake, George; Segura, Antígona
2013-05-01
Every Galactic environment is characterized by a stellar density and a velocity dispersion. With this information from literature, we simulated flyby encounters for several Galactic regions, numerically calculating stellar trajectories as well as orbits for particles in disks; our aim was to understand the effect of typical stellar flybys on planetary (debris) disks in the Milky Way Galaxy. For the solar neighborhood, we examined nearby stars with known distance, proper motions, and radial velocities. We found occurrence of a disturbing impact to the solar planetary disk within the next 8 Myr to be highly unlikely; perturbations to the Oort cloud seem unlikely as well. Current knowledge of the full phase space of stars in the solar neighborhood, however, is rather poor; thus we cannot rule out the existence of a star that is more likely to approach than those for which we have complete kinematic information. We studied the effect of stellar encounters on planetary orbits within the habitable zones of stars in more crowded stellar environments, such as stellar clusters. We found that in open clusters habitable zones are not readily disrupted; this is true if they evaporate in less than 10(8) yr. For older clusters the results may not be the same. We specifically studied the case of Messier 67, one of the oldest open clusters known, and show the effect of this environment on debris disks. We also considered the conditions in globular clusters, the Galactic nucleus, and the Galactic bulge-bar. We calculated the probability of whether Oort clouds exist in these Galactic environments.
LoCuSS: THE SUNYAEV-ZEL'DOVICH EFFECT AND WEAK-LENSING MASS SCALING RELATION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marrone, Daniel P.; Carlstrom, John E.; Gralla, Megan
2012-08-01
We present the first weak-lensing-based scaling relation between galaxy cluster mass, M{sub WL}, and integrated Compton parameter Y{sub sph}. Observations of 18 galaxy clusters at z {approx_equal} 0.2 were obtained with the Subaru 8.2 m telescope and the Sunyaev-Zel'dovich Array. The M{sub WL}-Y{sub sph} scaling relations, measured at {Delta} = 500, 1000, and 2500 {rho}{sub c}, are consistent in slope and normalization with previous results derived under the assumption of hydrostatic equilibrium (HSE). We find an intrinsic scatter in M{sub WL} at fixed Y{sub sph} of 20%, larger than both previous measurements of M{sub HSE}-Y{sub sph} scatter as well asmore » the scatter in true mass at fixed Y{sub sph} found in simulations. Moreover, the scatter in our lensing-based scaling relations is morphology dependent, with 30%-40% larger M{sub WL} for undisturbed compared to disturbed clusters at the same Y{sub sph} at r{sub 500}. Further examination suggests that the segregation may be explained by the inability of our spherical lens models to faithfully describe the three-dimensional structure of the clusters, in particular, the structure along the line of sight. We find that the ellipticity of the brightest cluster galaxy, a proxy for halo orientation, correlates well with the offset in mass from the mean scaling relation, which supports this picture. This provides empirical evidence that line-of-sight projection effects are an important systematic uncertainty in lensing-based scaling relations.« less
Faires, Meredith C; Pearl, David L; Ciccotelli, William A; Berke, Olaf; Reid-Smith, Richard J; Weese, J Scott
2014-07-08
In healthcare facilities, conventional surveillance techniques using rule-based guidelines may result in under- or over-reporting of methicillin-resistant Staphylococcus aureus (MRSA) outbreaks, as these guidelines are generally unvalidated. The objectives of this study were to investigate the utility of the temporal scan statistic for detecting MRSA clusters, validate clusters using molecular techniques and hospital records, and determine significant differences in the rate of MRSA cases using regression models. Patients admitted to a community hospital between August 2006 and February 2011, and identified with MRSA>48 hours following hospital admission, were included in this study. Between March 2010 and February 2011, MRSA specimens were obtained for spa typing. MRSA clusters were investigated using a retrospective temporal scan statistic. Tests were conducted on a monthly scale and significant clusters were compared to MRSA outbreaks identified by hospital personnel. Associations between the rate of MRSA cases and the variables year, month, and season were investigated using a negative binomial regression model. During the study period, 735 MRSA cases were identified and 167 MRSA isolates were spa typed. Nine different spa types were identified with spa type 2/t002 (88.6%) the most prevalent. The temporal scan statistic identified significant MRSA clusters at the hospital (n=2), service (n=16), and ward (n=10) levels (P ≤ 0.05). Seven clusters were concordant with nine MRSA outbreaks identified by hospital staff. For the remaining clusters, seven events may have been equivalent to true outbreaks and six clusters demonstrated possible transmission events. The regression analysis indicated years 2009-2011, compared to 2006, and months March and April, compared to January, were associated with an increase in the rate of MRSA cases (P ≤ 0.05). The application of the temporal scan statistic identified several MRSA clusters that were not detected by hospital personnel. The identification of specific years and months with increased MRSA rates may be attributable to several hospital level factors including the presence of other pathogens. Within hospitals, the incorporation of the temporal scan statistic to standard surveillance techniques is a valuable tool for healthcare workers to evaluate surveillance strategies and aid in the identification of MRSA clusters.
NASA Astrophysics Data System (ADS)
Tchernin, C.; Bartelmann, M.; Huber, K.; Dekel, A.; Hurier, G.; Majer, C. L.; Meyer, S.; Zinger, E.; Eckert, D.; Meneghetti, M.; Merten, J.
2018-06-01
Context. The mass of galaxy clusters is not a direct observable, nonetheless it is commonly used to probe cosmological models. Based on the combination of all main cluster observables, that is, the X-ray emission, the thermal Sunyaev-Zel'dovich (SZ) signal, the velocity dispersion of the cluster galaxies, and gravitational lensing, the gravitational potential of galaxy clusters can be jointly reconstructed. Aims: We derive the two main ingredients required for this joint reconstruction: the potentials individually reconstructed from the observables and their covariance matrices, which act as a weight in the joint reconstruction. We show here the method to derive these quantities. The result of the joint reconstruction applied to a real cluster will be discussed in a forthcoming paper. Methods: We apply the Richardson-Lucy deprojection algorithm to data on a two-dimensional (2D) grid. We first test the 2D deprojection algorithm on a β-profile. Assuming hydrostatic equilibrium, we further reconstruct the gravitational potential of a simulated galaxy cluster based on synthetic SZ and X-ray data. We then reconstruct the projected gravitational potential of the massive and dynamically active cluster Abell 2142, based on the X-ray observations collected with XMM-Newton and the SZ observations from the Planck satellite. Finally, we compute the covariance matrix of the projected reconstructed potential of the cluster Abell 2142 based on the X-ray measurements collected with XMM-Newton. Results: The gravitational potentials of the simulated cluster recovered from synthetic X-ray and SZ data are consistent, even though the potential reconstructed from X-rays shows larger deviations from the true potential. Regarding Abell 2142, the projected gravitational cluster potentials recovered from SZ and X-ray data reproduce well the projected potential inferred from gravitational-lensing observations. We also observe that the covariance matrix of the potential for Abell 2142 reconstructed from XMM-Newton data sensitively depends on the resolution of the deprojected grid and on the smoothing scale used in the deprojection. Conclusions: We show that the Richardson-Lucy deprojection method can be effectively applied on a grid and that the projected potential is well recovered from real and simulated data based on X-ray and SZ signal. The comparison between the reconstructed potentials from the different observables provides additional information on the validity of the assumptions as function of the projected radius.
Ehlkes, Lutz; Eastwood, Keith; Webb, Cameron; Durrheim, David
2012-07-01
Barmah Forest virus (BFV) is a mosquito-borne virus causing epidemic polyarthritis in Australia. This study used case follow-up of cases from the surveillance system to demonstrate that routinely collected BFV notification data were an unreliable indicator of the true location of exposure. BFV notifications from June 2001 to May 2011 were extracted from the New South Wales (NSW) Notifiable Conditions Information Management System to study case distribution. Disease cluster analysis was performed using spatial scan statistics. Exposure history data were collected from cases notified in 2010 and 2011 to accurately determine travel to high-risk areas. Cluster analysis using address data identified an area of increased BFV disease incidence in the mid-north coast of NSW contiguous with estuarine wetlands. When travel to this area was investigated, 96.7% (29/30) cases reported having visited coastal regions within four weeks of developing symptoms. Along the central NSW coastline, extensive wetlands occur in close proximity to populated areas. These wetlands provide ideal breeding habitats for a range of mosquito species implicated in the transmission of BFV. This is the first study to fully assess case exposure with findings suggesting that sporadic cases of BFV in people living further away from the coast do not reflect alternative exposure sites but are likely to result from travel to coastal regions. Spatial analysis by case address alone may lead to inaccurate understandings of the true distribution of arboviral diseases. Subsequently, this information has important implications for the collection of mosquito-borne disease surveillance information and public health response strategies.
2013-01-01
Background The standard management in patients with thyroid nodules is to assess the risk of malignancy, based on cytological examination. On the other hand, there are thyroid patterns of ultrasound (US) image, associated with an increased risk of malignancy. The aim of our study was to create a diagnostic algorithm that would employ both data from US examination (expressed by a total score, according to our scoring system) and FNAB results, classified according to Bethesda system (The Bethesda System for Reporting Thyroid Cytopathology - TBSRTC categories). Material and methods 100 thyroid cancer foci (94 papillary carcinomas, 4 medullary carcinomas, 2 undifferentiated carcinomas) and 100 benign focal lesions were selected during postoperative histopathological examination of thyroid glands excised during surgery from 111 patients. The corresponding US images of each lesion – performed in the course of preoperative diagnostics – were evaluated for the presence of seven (7) different features in US image, suggesting a malignant character of lesion, viz. vascularity, i.e., the increased central intranodular blood flows, microcalcifications, “taller-than-wide” orientation, solid composition, hypoechogenicity, irregular margin and either absence of peripheral halo or the presence of outer shell of uneven thickness, surrounding the lesion. The sensitivity, specificity, positive predictive values, negative predictive values and odds ratios for each US feature were calculated. Results In US image of the analyzed cancer foci, we obtained the following values of odds ratio for each of the above mentioned features suggesting malignancy: “taller-than-wide” orientation - odds ratio - 301.0, microcalcifications - 24.67, increased intranodular vascularity - 20.44, hypoechogenicity - 18.61, irregular margins - 7.81, absence of halo - 5.88, and solid composition - 4.16. Taking into account our own experience and the present data, in juxtaposition with the opinions of other authors, we propose a division of US features into 3 groups of different prognostic importance, expressed by a total score calculated based on our scoring system. Accordingly, microcalcifications, “taller-than-wide” orientation, the increased intranodular vascularity, and hypoechogenicity constitute one group - each of the features in this group is awarded 1 point. In turn, the characteristics of minor prognostic importance, such as irregular margin, absence of halo, solid composition, and large size (a diameter longer than 3.0 cm) - are associated with the granting 0.5 points each. The most important prognostic features – a rapid growth (enlargement) of nodules/focal lesions and a presence of pathologically altered lymph nodes are associated with the granting 3 points for each. Our scoring system can be applied in order to better assessment of thyroid US patterns in whole. In patients with a total score ranging from 0 < 4 points there is US pattern of a low risk of malignancy, with ≥ 4 < 7 points - intermediate risk, and in patients with a score ≥ 7 points – a high risk in question. Conclusion Complementary use of our scoring system and FNAB TBSRTC categories can help to make optimal clinical decisions as regards the selection of treatment strategy. PMID:23601166
Adamczewski, Zbigniew; Lewiński, Andrzej
2013-01-01
The standard management in patients with thyroid nodules is to assess the risk of malignancy, based on cytological examination. On the other hand, there are thyroid patterns of ultrasound (US) image, associated with an increased risk of malignancy. The aim of our study was to create a diagnostic algorithm that would employ both data from US examination (expressed by a total score, according to our scoring system) and FNAB results, classified according to Bethesda system (The Bethesda System for Reporting Thyroid Cytopathology - TBSRTC categories). 100 thyroid cancer foci (94 papillary carcinomas, 4 medullary carcinomas, 2 undifferentiated carcinomas) and 100 benign focal lesions were selected during postoperative histopathological examination of thyroid glands excised during surgery from 111 patients. The corresponding US images of each lesion - performed in the course of preoperative diagnostics - were evaluated for the presence of seven (7) different features in US image, suggesting a malignant character of lesion, viz. vascularity, i.e., the increased central intranodular blood flows, microcalcifications, "taller-than-wide" orientation, solid composition, hypoechogenicity, irregular margin and either absence of peripheral halo or the presence of outer shell of uneven thickness, surrounding the lesion. The sensitivity, specificity, positive predictive values, negative predictive values and odds ratios for each US feature were calculated. IN US IMAGE OF THE ANALYZED CANCER FOCI, WE OBTAINED THE FOLLOWING VALUES OF ODDS RATIO FOR EACH OF THE ABOVE MENTIONED FEATURES SUGGESTING MALIGNANCY: "taller-than-wide" orientation - odds ratio - 301.0, microcalcifications - 24.67, increased intranodular vascularity - 20.44, hypoechogenicity - 18.61, irregular margins - 7.81, absence of halo - 5.88, and solid composition - 4.16. Taking into account our own experience and the present data, in juxtaposition with the opinions of other authors, we propose a division of US features into 3 groups of different prognostic importance, expressed by a total score calculated based on our scoring system. Accordingly, microcalcifications, "taller-than-wide" orientation, the increased intranodular vascularity, and hypoechogenicity constitute one group - each of the features in this group is awarded 1 point. In turn, the characteristics of minor prognostic importance, such as irregular margin, absence of halo, solid composition, and large size (a diameter longer than 3.0 cm) - are associated with the granting 0.5 points each. The most important prognostic features - a rapid growth (enlargement) of nodules/focal lesions and a presence of pathologically altered lymph nodes are associated with the granting 3 points for each. Our scoring system can be applied in order to better assessment of thyroid US patterns in whole. In patients with a total score ranging from 0 < 4 points there is US pattern of a low risk of malignancy, with ≥ 4 < 7 points - intermediate risk, and in patients with a score ≥ 7 points - a high risk in question. Complementary use of our scoring system and FNAB TBSRTC categories can help to make optimal clinical decisions as regards the selection of treatment strategy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiang, Yi-Kuan; Gebhardt, Karl; Overzier, Roderik
2014-02-10
To demonstrate the feasibility of studying the epoch of massive galaxy cluster formation in a more systematic manner using current and future galaxy surveys, we report the discovery of a large sample of protocluster candidates in the 1.62 deg{sup 2} COSMOS/UltraVISTA field traced by optical/infrared selected galaxies using photometric redshifts. By comparing properly smoothed three-dimensional galaxy density maps of the observations and a set of matched simulations incorporating the dominant observational effects (galaxy selection and photometric redshift uncertainties), we first confirm that the observed ∼15 comoving Mpc-scale galaxy clustering is consistent with ΛCDM models. Using further the relation between high-z overdensitymore » and the present day cluster mass calibrated in these matched simulations, we found 36 candidate structures at 1.6 < z < 3.1, showing overdensities consistent with the progenitors of M{sub z} {sub =} {sub 0} ∼ 10{sup 15} M {sub ☉} clusters. Taking into account the significant upward scattering of lower mass structures, the probabilities for the candidates to have at least M{sub z=} {sub 0} ∼ 10{sup 14} M {sub ☉} are ∼70%. For each structure, about 15%-40% of photometric galaxy candidates are expected to be true protocluster members that will merge into a cluster-scale halo by z = 0. With solely photometric redshifts, we successfully rediscover two spectroscopically confirmed structures in this field, suggesting that our algorithm is robust. This work generates a large sample of uniformly selected protocluster candidates, providing rich targets for spectroscopic follow-up and subsequent studies of cluster formation. Meanwhile, it demonstrates the potential for probing early cluster formation with upcoming redshift surveys such as the Hobby-Eberly Telescope Dark Energy Experiment and the Subaru Prime Focus Spectrograph survey.« less
Insights into the Vitis complex in the Danube floodplain (Austria).
Arnold, Claire; Bachmann, Olivier; Schnitzler, Annik
2017-10-01
European grapevine populations quickly disappeared from most of their range, massively killed by the spread of North American grapevine pests and diseases. Nowadays taxonomic pollution represents a new threat. A large Vitis complex involves escaped cultivars, rootstocks, and wild grapevines. The study aimed to provide insight into the Vitis complex in the Danube region through field and genetic analyses. Among the five other major rivers in Europe which still host wild grapevine populations, the Danube floodplain is the only one benefiting from an extensive protected forest area (93 km²) and an relatively active dynamic flood pulse. The Donau-Auen National Park also regroups the largest wild grapevine population in Europe. Ninety-two percent of the individuals collected in the park were true wild grapevines, and 8% were hybrids and introgressed individuals of rootstocks, wild grapevines, and cultivars. These three groups are interfertile acting either as pollen donor or receiver. Hybrids were established within and outside the dykes, mostly in anthropized forest edges. The best-developed individuals imply rootstock genes. They establish in the most erosive parts of the floodplain. 42% of the true wild grapevines lived at the edges of forest/meadow, 33.3% at the edges forest/channels, and 23.9% in forest gaps. DBH (Diameter Breast Height) varied significantly with the occurrence of flooding. Clones were found in both true wild and hybrids/introgressed grapevines. The process of cloning seemed to be prevented in places where flooding dynamics is reduced. The current global distribution of true wild grapevines shows a strong tendency toward clustering, in sites where forestry practices were the most extensive. However, the reduced flooding activity is a danger for long-term sustainability of the natural wild grapevine population.
Sherman, David M.
1991-01-01
The electronic structure of magnesiowustite is investigated using self-consistent field X?? scattered wave (SCF-X??-SW) molecular orbital calculations on (FeO6)10- and (FeMg12O14)2- clusters. Calculated one-electron transition energies are used to interpret the optical spectrum of (Mg, Fe)O. The results are applied to the electrical and thermal conductivity of the lower mantle. This is especially true if Fe2+ adopts the low-spin configuration. The geophysically significant properties of (Fe, Mg)O probably result from defect Fe3+. -from Author
The signal of weak gravitational lensing from galaxy groups and clusters
NASA Astrophysics Data System (ADS)
Markert, Sean
2017-02-01
The weak gravitational lensing of galaxy clusters is a valuable tool. The deflection of light around a lens is solely dependent on the underlying distribution of foreground mass, and independent of tracers of mass such as the mass to light ratio and kinematics. As a direct probe of mass, weak lensing serves as an independent calibration of mass-observable relationships. These massive clusters are objects of great interest to astronomers, as their abundance is dependent on the conditions of the early universe, and accurate counts of clusters serve as a test of cosmological model. Upcoming surveys, such as LSST and DES, promise to push the limit of observable weak lensing, detecting clusters and sources at higher redshift than has ever been detected before. This makes accurate counts of clusters of a given mass and redshift, and proper calibration of mass-observable relationships, vital to cosmological studies. We used M> 1013.5 h-1M ⊙ halos from the MultiDark Planck simulation at z 0.5 to study the behavior of the reduced shear in clusters. We generated 2D maps of convergence and shear the halos using the GLAMER lensing library. Using these maps, we simulated observations of randomly placed background sources, and generate azimuthal averages of the shear. This reduced shear profile, and the true reduced shear profile of the halo, is fit using analytical solutions for shear of the NFW, Einasto, and truncated NFW density profile. The masses of these density profiles are then compared to the total halo masses from the halo catalogs. We find that fits to the reduced shear for halos extending past ≈ 2 h-1Mpc are fits to the noise of large scale structure along the line of sight. This noise is largely in the 45° rotated component to the reduced tangential shear, and is a breakdown in the approximation of gtan ≈ gnot required for density profile fitting of clusters. If fits are constrained to a projected radii of < 2 h-1Mpc, we see massively improved fits insensitive to the amount of structure present along the line of sight.
Nagasawa, Hatsumi; Lin, Yu-Fen; Kato, Takamitsu A; Brogan, John R; Shih, Hung-Ying; Kurimasa, Akihiro; Bedford, Joel S; Chen, Benjamin P C; Little, John B
2017-02-01
The catalytic subunit of DNA dependent protein kinase (DNA-PKcs) and its kinase activity are critical for mediation of non-homologous end-joining (NHEJ) of DNA double-strand breaks (DSB) in mammalian cells after gamma-ray irradiation. Additionally, DNA-PKcs phosphorylations at the T2609 cluster and the S2056 cluster also affect DSB repair and cellular sensitivity to gamma radiation. Previously we reported that phosphorylations within these two regions affect not only NHEJ but also homologous recombination repair (HRR) dependent DSB repair. In this study, we further examine phenotypic effects on cells bearing various combinations of mutations within either or both regions. Effects studied included cell killing as well as chromosomal aberration induction after 0.5-8 Gy gamma-ray irradiation delivered to synchronized cells during the G 0 /G 1 phase of the cell cycle. Blocking phosphorylation within the T2609 cluster was most critical regarding sensitization and depended on the number of available phosphorylation sites. It was also especially interesting that only one substitution of alanine in each of the two clusters separately abolished the restoration of wild-type sensitivity by DNA-PKcs. Similar patterns were seen for induction of chromosomal aberrations, reflecting their connection to cell killing. To study possible change in coordination between HRR and NHEJ directed repair in these DNA-PKcs mutant cell lines, we compared the induction of sister chromatid exchanges (SCEs) by very low fluencies of alpha particles with mutant cells defective in the HRR pathway that is required for induction of SCEs. Levels of true SCEs induced by very low fluence of alpha-particle irradiation normally seen in wild-type cells were only slightly decreased in the S2056 cluster mutants, but were completely abolished in the T2609 cluster mutants and were indistinguishable from levels seen in HRR deficient cells. Again, a single substitution in the S2056 together with a single substitution in the T2609 cluster abolished SCE formation and thus also effectively interferes with HRR.
Lensing is low: cosmology, galaxy formation or new physics?
NASA Astrophysics Data System (ADS)
Leauthaud, Alexie; Saito, Shun; Hilbert, Stefan; Barreira, Alexandre; More, Surhud; White, Martin; Alam, Shadab; Behroozi, Peter; Bundy, Kevin; Coupon, Jean; Erben, Thomas; Heymans, Catherine; Hildebrandt, Hendrik; Mandelbaum, Rachel; Miller, Lance; Moraes, Bruno; Pereira, Maria E. S.; Rodríguez-Torres, Sergio A.; Schmidt, Fabian; Shan, Huan-Yuan; Viel, Matteo; Villaescusa-Navarro, Francisco
2017-05-01
We present high signal-to-noise galaxy-galaxy lensing measurements of the Baryon Oscillation Spectroscopic Survey constant mass (CMASS) sample using 250 deg2 of weak-lensing data from Canada-France-Hawaii Telescope Lensing Survey and Canada-France-Hawaii Telescope Stripe 82 Survey. We compare this signal with predictions from mock catalogues trained to match observables including the stellar mass function and the projected and two-dimensional clustering of CMASS. We show that the clustering of CMASS, together with standard models of the galaxy-halo connection, robustly predicts a lensing signal that is 20-40 per cent larger than observed. Detailed tests show that our results are robust to a variety of systematic effects. Lowering the value of S_8=σ _8 \\sqrt{Ω _m/0.3} compared to Planck Collaboration XIII reconciles the lensing with clustering. However, given the scale of our measurement (r < 10 h-1 Mpc), other effects may also be at play and need to be taken into consideration. We explore the impact of baryon physics, assembly bias, massive neutrinos and modifications to general relativity on ΔΣ and show that several of these effects may be non-negligible given the precision of our measurement. Disentangling cosmological effects from the details of the galaxy-halo connection, the effect of baryons, and massive neutrinos, is the next challenge facing joint lensing and clustering analyses. This is especially true in the context of large galaxy samples from Baryon Acoustic Oscillation surveys with precise measurements but complex selection functions.
Using the XMM-Newton Optical Monitor to Study Cluster Galaxy Evolution
NASA Technical Reports Server (NTRS)
Miller, Neal A.; O'Steen, Richard; Yen, Steffi; Kuntz, K. D.; Hammer, Derek
2012-01-01
We explore the application of XMM Newton Optical Monitor (XMM-OM) ultraviolet (UV) data to study galaxy evolution. Our sample is constructed as the intersection of all Abell clusters with z < 0.05 and having archival XMM-OM data in either the UVM2 or UVW1 filters, plus optical and UV photometry from the Sloan Digital Sky Survey and GALEX, respectively. The 11 resulting clusters include 726 galaxies with measured redshifts, 520 of which have redshifts placing them within their parent Abell clusters. We develop procedures for manipulating the XMM-OM images and measuring galaxy photometry from them, and we confirm our results via comparison with published catalogs. Color-magnitude diagrams (CMDs) constructed using the XMM-OM data along with SDSS optical data show promise for evolutionary studies, with good separation between red and blue sequences and real variation in the width of the red sequence that is likely indicative of differences in star formation history. This is particularly true for UVW1 data, as the relative abundance of data collected using this filter and its depth make it an attractive choice. Available tools that use stellar synthesis libraries to fit the UV and optical photometric data may also be used, thereby better describing star formation history within the past billion years and providing estimates of total stellar mass that include contributions from young stars. Finally, color-color diagrams that include XMM-OM UV data appear useful to the photometric identification of both extragalactic and stellar sources.
Using the XMM-Newton Optical Monitor to Study Cluster Galaxy Evolution
NASA Astrophysics Data System (ADS)
Miller, Neal A.; O'Steen, Richard; Yen, Steffi; Kuntz, K. D.; Hammer, Derek
2012-02-01
We explore the application of XMM-Newton Optical Monitor (XMM-OM) ultraviolet (UV) data to study galaxy evolution. Our sample is constructed as the intersection of all Abell clusters with z < 0.05 and having archival XMM-OM data in either the UVM2 or UVW1 filters, plus optical and UV photometry from the Sloan Digital Sky Survey and GALEX, respectively. The 11 resulting clusters include 726 galaxies with measured redshifts, 520 of which have redshifts placing them within their parent Abell clusters. We develop procedures for manipulating the XMM-OM images and measuring galaxy photometry from them, and we confirm our results via comparison with published catalogs. Color-magnitude diagrams (CMDs) constructed using the XMM-OM data along with SDSS optical data show promise for evolutionary studies, with good separation between red and blue sequences and real variation in the width of the red sequence that is likely indicative of differences in star formation history. This is particularly true for UVW1 data, as the relative abundance of data collected using this filter and its depth make it an attractive choice. Available tools that use stellar synthesis libraries to fit the UV and optical photometric data may also be used, thereby better describing star formation history within the past billion years and providing estimates of total stellar mass that include contributions from young stars. Finally, color-color diagrams that include XMM-OM UV data appear useful to the photometric identification of both extragalactic and stellar sources.
Natural Product Biosynthetic Diversity and Comparative Genomics of the Cyanobacteria.
Dittmann, Elke; Gugger, Muriel; Sivonen, Kaarina; Fewer, David P
2015-10-01
Cyanobacteria are an ancient lineage of slow-growing photosynthetic bacteria and a prolific source of natural products with intricate chemical structures and potent biological activities. The bulk of these natural products are known from just a handful of genera. Recent efforts have elucidated the mechanisms underpinning the biosynthesis of a diverse array of natural products from cyanobacteria. Many of the biosynthetic mechanisms are unique to cyanobacteria or rarely described from other organisms. Advances in genome sequence technology have precipitated a deluge of genome sequences for cyanobacteria. This makes it possible to link known natural products to biosynthetic gene clusters but also accelerates the discovery of new natural products through genome mining. These studies demonstrate that cyanobacteria encode a huge variety of cryptic gene clusters for the production of natural products, and the known chemical diversity is likely to be just a fraction of the true biosynthetic capabilities of this fascinating and ancient group of organisms. Copyright © 2015. Published by Elsevier Ltd.
Galaxy Formation from the Primordial Black Holes
NASA Astrophysics Data System (ADS)
Morikawa, Masahiro
2017-12-01
Supermassive black hole (SMBH) of size MBH = 106-10M⊙ is common in the Universe and it defines the center of the galaxy. A galaxy and the SMBH are generally thought to have co-evolved. However, the SMBH cannot evolve so fast as commonly observed even at redshift z > 6. Therefore, we explore a natural hypothesis that the SMBH has been already formed mature at z ⪆ 10 before stars and galaxies. The SMBH forms energetic jets and out-flows which trigger massive star formation in the ambient gas. They eventually construct globular clusters and classical bulge as well as the body of elliptical galaxies. We propose simple models which implement these processes. We point out that the globular clusters and classical bulges have a common origin but are in different phases. The same is true for the elliptical and spiral galaxies. Physics behind these phase division is the runaway star formation process with strong feedback to SMBH. This is similar to the forest-fire model that displays self-organized criticality.
Motivations for sex among low-income African American young women.
Deardorff, Julianna; Suleiman, Ahna Ballonoff; Dal Santo, Teresa S; Flythe, Michelle; Gurdin, J Barry; Eyre, Stephen L
2013-12-01
African American young women exhibit higher risk for sexually transmitted infections, including HIV/AIDS, compared with European American women, and this is particularly true for African American women living in low-income contexts. We used rigorous qualitative methods, that is, domain analysis, including free listing (n = 20), similarity assessment (n = 25), and focus groups (four groups), to elicit self-described motivations for sex among low-income African American young women (19-22 years). Analyses revealed six clusters: Love/Feelings, For Fun, Curiosity, Pressured, For Money, and For Material Things. Focus groups explored how African American women interpreted the clusters in light of condom use expectations. Participants expressed the importance of using condoms in risky situations, yet endorsed condom use during casual sexual encounters less than half the time. This study highlights the need for more effective intervention strategies to increase condom use expectations among low-income African American women, particularly in casual relationships where perceived risk is already high.
Estimating and Identifying Unspecified Correlation Structure for Longitudinal Data
Hu, Jianhua; Wang, Peng; Qu, Annie
2014-01-01
Identifying correlation structure is important to achieving estimation efficiency in analyzing longitudinal data, and is also crucial for drawing valid statistical inference for large size clustered data. In this paper, we propose a nonparametric method to estimate the correlation structure, which is applicable for discrete longitudinal data. We utilize eigenvector-based basis matrices to approximate the inverse of the empirical correlation matrix and determine the number of basis matrices via model selection. A penalized objective function based on the difference between the empirical and model approximation of the correlation matrices is adopted to select an informative structure for the correlation matrix. The eigenvector representation of the correlation estimation is capable of reducing the risk of model misspecification, and also provides useful information on the specific within-cluster correlation pattern of the data. We show that the proposed method possesses the oracle property and selects the true correlation structure consistently. The proposed method is illustrated through simulations and two data examples on air pollution and sonar signal studies. PMID:26361433
Leitão, Alexandre B; Sucena, Élio
2015-01-01
Virtually all species of coelomate animals contain blood cells that display a division of labor necessary for homeostasis. This functional partition depends upon the balance between proliferation and differentiation mostly accomplished in the hematopoietic organs. In Drosophila melanogaster, the lymph gland produces plasmatocytes and crystal cells that are not released until pupariation. Yet, throughout larval development, both hemocyte types increase in numbers. Mature plasmatocytes can proliferate but it is not known if crystal cell numbers increase by self-renewal or by de novo differentiation. We show that new crystal cells in third instar larvae originate through a Notch-dependent process of plasmatocyte transdifferentiation. This process occurs in the sessile clusters and is contingent upon the integrity of these structures. The existence of this hematopoietic tissue, relying on structure-dependent signaling events to promote blood homeostasis, creates a new paradigm for addressing outstanding questions in Drosophila hematopoiesis and establishing further parallels with vertebrate systems. DOI: http://dx.doi.org/10.7554/eLife.06166.001 PMID:25650737
Bellairs, R; Veini, M
1984-02-01
A new theory of control of somite segmentation in chick embryos is proposed. This supposses that tiny clusters of already programmed cells are present throughout the presumptive somite area at stage 4, but that in order to fulfill their destiny they probably depend on the addition of further cells from the primitive streak. Evidence is based on the two groups of experiments: a) Experiments involving transection across the primitive streak at various stages, (which results in a 'tail' which possesses mesodermal derivatives) and across the segmental plate (which results in a 'tail' lacking mesodermal derivatives). b) Experiments in which parts of embryos have been explanted with or without their primitive streak. It is suggested that the initial clusters of pre-programmed cells move further and further posteriorly, developing into somitomeres (the precursors of true somites) only as they receive re-inforcements from the primitive streak or, ultimately, from the tail bud.
Screening interspecific hybrids of Populus (P. ciliata x maximowiczii) using AFLP markers.
Chauhan, N; Negi, M S; Sabharwal, V; Khurana, D K; Lakshmikumaran, M
2004-03-01
Hybrids of Populus ciliata x maximowiczii are very vigorous and outperform both the parents in growth performance and yield. Genetic evaluation of 24 of these interspecific hybrids along with the two mother trees ( Populus ciliata), and five male-parent ( Populus maximowiczii) genotypes was carried out using the AFLP marker assay. Eight AFLP primer combinations detected 428 markers, of which 280 (66%) were polymorphic. Genetic relationships within the samples were evaluated by generating the similarity matrix based on Jaccard's coefficient. The phenetic dendrograms, as well as the PCO plots, separated the hybrids and the two parent species into three distinct clusters. The hybrids grouped closer to the P. ciliata (female parent) cluster as compared to the P. maximowiczii (male parent) cluster. The hybrid cluster contained internal groupings, which correlated to some extent with growth performance. The four best performing hybrids (42m1, 65m1, 23m2, Cm2-5-20/91) formed a distinct sub-cluster. Data from a single primer combination was sufficient for distinguishing the hybrids from the parents and assigning paternity. The hybrids showed 22 markers that were absent in P. ciliata but were monomorphically present in all the hybrids, suggesting outcrossing and common paternity. Further, these 22 markers were found in all the P. maximowiczii genotypes confirming it as the male parent. These male-specific markers can be converted to SCAR markers and used for rapid screening of the P.ciliata x maximowiczii hybrids. The primer combination E-AAC x M-CAA was identified as most suitable for ascertaining true hybridity. AFLP proves to be a useful tool for screening of P. ciliata x maximowiczii hybrids at the early stages of development.
Habitability in Different Milky Way Stellar Environments: A Stellar Interaction Dynamical Approach
Pichardo, Bárbara; Lake, George; Segura, Antígona
2013-01-01
Abstract Every Galactic environment is characterized by a stellar density and a velocity dispersion. With this information from literature, we simulated flyby encounters for several Galactic regions, numerically calculating stellar trajectories as well as orbits for particles in disks; our aim was to understand the effect of typical stellar flybys on planetary (debris) disks in the Milky Way Galaxy. For the solar neighborhood, we examined nearby stars with known distance, proper motions, and radial velocities. We found occurrence of a disturbing impact to the solar planetary disk within the next 8 Myr to be highly unlikely; perturbations to the Oort cloud seem unlikely as well. Current knowledge of the full phase space of stars in the solar neighborhood, however, is rather poor; thus we cannot rule out the existence of a star that is more likely to approach than those for which we have complete kinematic information. We studied the effect of stellar encounters on planetary orbits within the habitable zones of stars in more crowded stellar environments, such as stellar clusters. We found that in open clusters habitable zones are not readily disrupted; this is true if they evaporate in less than 108 yr. For older clusters the results may not be the same. We specifically studied the case of Messier 67, one of the oldest open clusters known, and show the effect of this environment on debris disks. We also considered the conditions in globular clusters, the Galactic nucleus, and the Galactic bulge-bar. We calculated the probability of whether Oort clouds exist in these Galactic environments. Key Words: Stellar interactions—Galactic habitable zone—Oort cloud. Astrobiology 13, 491–509. PMID:23659647
Near-IR period-luminosity relations for pulsating stars in ω Centauri (NGC 5139)
NASA Astrophysics Data System (ADS)
Navarrete, C.; Catelan, M.; Contreras Ramos, R.; Alonso-García, J.; Gran, F.; Dékány, I.; Minniti, D.
2017-08-01
Aims: The globular cluster ω Centauri (NGC 5139) hosts hundreds of pulsating variable stars of different types, thus representing a treasure trove for studies of their corresponding period-luminosity (PL) relations. Our goal in this study is to obtain the PL relations for RR Lyrae and SX Phoenicis stars in the field of the cluster, based on high-quality, well-sampled light curves in the near-infrared (IR). Methods: Observations were carried out using the VISTA InfraRed CAMera (VIRCAM) mounted on the Visible and Infrared Survey Telescope for Astronomy (VISTA). A total of 42 epochs in J and 100 epochs in KS were obtained, spanning 352 days. Point-spread function photometry was performed using DoPhot and DAOPHOT crowded-field photometry packages in the outer and inner regions of the cluster, respectively. Results: Based on the comprehensive catalog of near-IR light curves thus secured, PL relations were obtained for the different types of pulsators in the cluster, both in the J and KS bands. This includes the first PL relations in the near-IR for fundamental-mode SX Phoenicis stars. The near-IR magnitudes and periods of Type II Cepheids and RR Lyrae stars were used to derive an updated true distance modulus to the cluster, with a resulting value of (m - M)0 = 13.708 ± 0.035 ± 0.10 mag, where the error bars correspond to the adopted statistical and systematic errors, respectively. Adding the errors in quadrature, this is equivalent to a heliocentric distance of 5.52 ± 0.27 kpc. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile, with the VISTA telescope (project ID 087.D-0472, PI R. Angeloni).
Improving cluster-based missing value estimation of DNA microarray data.
Brás, Lígia P; Menezes, José C
2007-06-01
We present a modification of the weighted K-nearest neighbours imputation method (KNNimpute) for missing values (MVs) estimation in microarray data based on the reuse of estimated data. The method was called iterative KNN imputation (IKNNimpute) as the estimation is performed iteratively using the recently estimated values. The estimation efficiency of IKNNimpute was assessed under different conditions (data type, fraction and structure of missing data) by the normalized root mean squared error (NRMSE) and the correlation coefficients between estimated and true values, and compared with that of other cluster-based estimation methods (KNNimpute and sequential KNN). We further investigated the influence of imputation on the detection of differentially expressed genes using SAM by examining the differentially expressed genes that are lost after MV estimation. The performance measures give consistent results, indicating that the iterative procedure of IKNNimpute can enhance the prediction ability of cluster-based methods in the presence of high missing rates, in non-time series experiments and in data sets comprising both time series and non-time series data, because the information of the genes having MVs is used more efficiently and the iterative procedure allows refining the MV estimates. More importantly, IKNN has a smaller detrimental effect on the detection of differentially expressed genes.
Sideloading - Ingestion of Large Point Clouds Into the Apache Spark Big Data Engine
NASA Astrophysics Data System (ADS)
Boehm, J.; Liu, K.; Alis, C.
2016-06-01
In the geospatial domain we have now reached the point where data volumes we handle have clearly grown beyond the capacity of most desktop computers. This is particularly true in the area of point cloud processing. It is therefore naturally lucrative to explore established big data frameworks for big geospatial data. The very first hurdle is the import of geospatial data into big data frameworks, commonly referred to as data ingestion. Geospatial data is typically encoded in specialised binary file formats, which are not naturally supported by the existing big data frameworks. Instead such file formats are supported by software libraries that are restricted to single CPU execution. We present an approach that allows the use of existing point cloud file format libraries on the Apache Spark big data framework. We demonstrate the ingestion of large volumes of point cloud data into a compute cluster. The approach uses a map function to distribute the data ingestion across the nodes of a cluster. We test the capabilities of the proposed method to load billions of points into a commodity hardware compute cluster and we discuss the implications on scalability and performance. The performance is benchmarked against an existing native Apache Spark data import implementation.
Estimation of Rank Correlation for Clustered Data
Rosner, Bernard; Glynn, Robert
2017-01-01
It is well known that the sample correlation coefficient (Rxy) is the maximum likelihood estimator (MLE) of the Pearson correlation (ρxy) for i.i.d. bivariate normal data. However, this is not true for ophthalmologic data where X (e.g., visual acuity) and Y (e.g., visual field) are available for each eye and there is positive intraclass correlation for both X and Y in fellow eyes. In this paper, we provide a regression-based approach for obtaining the MLE of ρxy for clustered data, which can be implemented using standard mixed effects model software. This method is also extended to allow for estimation of partial correlation by controlling both X and Y for a vector U of other covariates. In addition, these methods can be extended to allow for estimation of rank correlation for clustered data by (a) converting ranks of both X and Y to the probit scale, (b) estimating the Pearson correlation between probit scores for X and Y, and (c) using the relationship between Pearson and rank correlation for bivariate normally distributed data. The validity of the methods in finite-sized samples is supported by simulation studies. Finally, two examples from ophthalmology and analgesic abuse are used to illustrate the methods. PMID:28399615
Merocyclophanes C and D from the Cultured Freshwater Cyanobacterium Nostoc sp. (UIC 10110).
May, Daniel S; Chen, Wei-Lun; Lantvit, Daniel D; Zhang, Xiaoli; Krunic, Aleksej; Burdette, Joanna E; Eustaquio, Alessandra; Orjala, Jimmy
2017-04-28
Merocyclophanes C and D (1 and 2) were isolated from the cell extract of the cultured cyanobacterium UIC 10110. The structures were determined by one-dimensional nuclear magnetic resonance (NMR) and high-resolution electrospray ionization mass spectrometry and confirmed by 2D NMR techniques. The absolute configurations were determined using electronic circular dichroism spectroscopy. Merocyclophanes C and D represent the first known analogues of the merocyclophane core structure, a recently discovered scaffold of [7,7] paracyclophanes characterized by an α-branched methyl at C-1/C-14; 1 and 2 showed antiproliferative activity against the MDA-MB-435 cell line with IC 50 values of 1.6 and 0.9 μM, respectively. Partial 16S analysis determined UIC 10110 to be a Nostoc sp., and it was found to clade with UIC 10062 Nostoc sp., the only other strain known to produce merocyclophanes. The genome of UIC 10110 was sequenced, and a biosynthetic gene cluster was identified that is proposed to encode type I and type III polyketide synthases that are potentially responsible for production of the merocyclophanes; however, further experiments will be required to verify the true function of the gene cluster. The gene cluster provides a genetic basis for the observed structural differences of the [7,7] paracyclophane core structures.
The acute monocytic leukemias: multidisciplinary studies in 45 patients.
Straus, D J; Mertelsmann, R; Koziner, B; McKenzie, S; de Harven, E; Arlin, Z A; Kempin, S; Broxmeyer, H; Moore, M A; Menendez-Botet, C J; Gee, T S; Clarkson, B D
1980-11-01
The clinical and laboratory features of 37 patients with variants of acute monocytic leukemia are described. Three of these 37 patients who had extensive extramedullary leukemic tissue infiltration are examples of true histiocytic "lymphomas." Three additional patients with undifferentiated leukemias, one patient with refractory anemia with excess of blasts, one patient with chronic myelomonocytic leukemia, one patient with B-lymphocyte diffuse "histiocytic" lymphoma and one patient with "null" cell, terminal deoxynucleotidyl transferase-positive lymphoblastic lymphoma had bone marrow cells with monocytic features. Another patient had dual populations of lymphoid and monocytoid leukemic cells. The true monocytic leukemias, acute monocytic leukemia (AMOL) and acute myelomonocytic leukemia (AMMOL), are closely related to acute myelocytic leukemia (AML) morphologically and by their response to chemotherapy. like AML, the leukemic cells from the AMMOL and AMOL patients form leukemic clusters in semisolid media. Cytochemical staining of leukemic cells for nonspecific esterases, presence of Fc receptor on the cell surface, phagocytic ability, low TdT activity, presence of surface "ruffles" and "ridges" on scanning EM, elevations of serum lysozyme, and clinical manifestations of leukemic tissue infiltration are features which accompanied monocytic differentiation in these cases.
All Impostors Aren't Alike - Differentiating the Impostor Phenomenon.
Leonhardt, Mona; Bechtoldt, Myriam N; Rohrmann, Sonja
2017-01-01
Following up on earlier investigations, the present paper analyzes construct validity of the impostor phenomenon. It examines the question whether the impostor phenomenon is a homogeneous construct or whether different types of persons with impostor self-concept can be distinguished on the basis of related characteristics. The study was conducted with professionals in leadership positions exhibiting a pronounced impostor self-concept ( n = 183). Cluster-analytic procedures indicated the existence of two different types: one group which, in line with the literature (e.g., Clance, 1985), possessed traits classified as fairly unfavorable ("true impostors") and another group which can be described as largely unencumbered ("strategic impostors"). The present study suggests two types of impostorism: "True" impostors characterized by the negative self-views associated with the construct definition, and more "strategic" impostors who seem to be less encumbered by self-doubt. It is assumed that "strategic impostors" are characterized by a form of deliberate self-presentation. Therefore, the impostor self-concept cannot principally be viewed as a dysfunctional personality style. This distinction should be more carefully considered in further research and in therapeutic interventions.
Associations between dairy cow inter-service interval and probability of conception.
Remnant, J G; Green, M J; Huxley, J N; Hudson, C D
2018-07-01
Recent research has indicated that the interval between inseminations in modern dairy cattle is often longer than the commonly accepted cycle length of 18-24 days. This study analysed 257,396 inseminations in 75,745 cows from 312 herds in England and Wales. The interval between subsequent inseminations in the same cow in the same lactation (inter-service interval, ISI) were calculated and inseminations categorised as successful or unsuccessful depending on whether there was a corresponding calving event. Conception risk was calculated for each individual ISI between 16 and 28 days. A random effects logistic regression model was fitted to the data with pregnancy as the outcome variable and ISI (in days) included in the model as a categorical variable. The modal ISI was 22 days and the peak conception risk was 44% for ISIs of 21 days rising from 27% at 16 days. The logistic regression model revealed significant associations of conception risk with ISI as well as 305 day milk yield, insemination number, parity and days in milk. Predicted conception risk was lower for ISIs of 16, 17 and 18 days and higher for ISIs of 20, 21 and 22 days compared to 25 day ISIs. A mixture model was specified to identify clusters in insemination frequency and conception risk for ISIs between 3 and 50 days. A "high conception risk, high insemination frequency" cluster was identified between 19 and 26 days which indicated that this time period was the true latent distribution for ISI with optimal reproductive outcome. These findings suggest that the period of increased numbers of inseminations around 22 days identified in existing work coincides with the period of increased probability of conception and therefore likely represents true return estrus events. Copyright © 2018 Elsevier Inc. All rights reserved.
Lobular intraepithelial neoplasia arising within breast fibroadenoma
2013-01-01
Background Fibroadenomas are the second most common breast pathology occurring in young women under the age of 35 years old. Fibroadenomas can be classified as simple or complex according to histological features. Complex fibroadenomas differ from simple fibroadenomas because of the presence of cysts (3 mm), sclerosing adenosis, epithelial calcifications, or papillary apocrine changes. Most fibroadenomas are clinically identifiable. In 25% of cases, fibroadenomas are non-palpable and are diagnosed with mammography and ultrasound. Differential diagnosis with well differentiated breast cancer is often necessary, particularly with medullary or mucinous tumors. Calcification findings within fibroadenomas by mammogram have to be investigated. The age of a lump is usually reflected by calcifications. Microcalcification can hide foci of carcinoma in situ when they are small, branching type, and heterogeneous. However, many morphological possibilities may not be reliable for deciding whether a certain calcification is the product of a malignant or a benign process. From a radiological point of view, fibroadenomas containing foci of carcinoma in situ can be indistinguishable from benign lesions, even if the incidence of carcinoma within fibroadenomas is estimated as 0.1–0.3%, and it could be a long-term risk factor for invasive breast cancer. Case presentation A 44-year-old woman presented with a 1.5-cm palpable, smooth, mobile lump in the lower-inner quadrant of her right breast. Standard mediolateral oblique and craniocaudal mammograms showed a cluster of eccentric popcorn-like calcifications within the fibroadenoma. After lumpectomy, a definitive histological examination confirmed the intra-operative diagnosis of a benign mass. However, lobular intraepithelial neoplasia foci were found, surrounded by atypical lobular hyperplasia. Conclusions The possibility of an old benign breast lump might be supported by fine needle aspiration biopsy or core biopsy before initiating follow-up. According to our experience, when patients are older than 40 years and have a familial history of breast cancer, we prefer to carry out lumpectomy with follow up to avoid the risk of underestimation in situ foci within the lump. PMID:23849288
GPCALMA: A Tool For Mammography With A GRID-Connected Distributed Database
NASA Astrophysics Data System (ADS)
Bottigli, U.; Cerello, P.; Cheran, S.; Delogu, P.; Fantacci, M. E.; Fauci, F.; Golosio, B.; Lauria, A.; Lopez Torres, E.; Magro, R.; Masala, G. L.; Oliva, P.; Palmiero, R.; Raso, G.; Retico, A.; Stumbo, S.; Tangaro, S.
2003-09-01
The GPCALMA (Grid Platform for Computer Assisted Library for MAmmography) collaboration involves several departments of physics, INFN (National Institute of Nuclear Physics) sections, and italian hospitals. The aim of this collaboration is developing a tool that can help radiologists in early detection of breast cancer. GPCALMA has built a large distributed database of digitised mammographic images (about 5500 images corresponding to 1650 patients) and developed a CAD (Computer Aided Detection) software which is integrated in a station that can also be used to acquire new images, as archive and to perform statistical analysis. The images (18×24 cm2, digitised by a CCD linear scanner with a 85 μm pitch and 4096 gray levels) are completely described: pathological ones have a consistent characterization with radiologist's diagnosis and histological data, non pathological ones correspond to patients with a follow up at least three years. The distributed database is realized throught the connection of all the hospitals and research centers in GRID tecnology. In each hospital local patients digital images are stored in the local database. Using GRID connection, GPCALMA will allow each node to work on distributed database data as well as local database data. Using its database the GPCALMA tools perform several analysis. A texture analysis, i.e. an automated classification on adipose, dense or glandular texture, can be provided by the system. GPCALMA software also allows classification of pathological features, in particular massive lesions (both opacities and spiculated lesions) analysis and microcalcification clusters analysis. The detection of pathological features is made using neural network software that provides a selection of areas showing a given "suspicion level" of lesion occurrence. The performance of the GPCALMA system will be presented in terms of the ROC (Receiver Operating Characteristic) curves. The results of GPCALMA system as "second reader" will also be presented.
NASA Astrophysics Data System (ADS)
Cummings, Jeffrey D.; Kalirai, Jason S.; Tremblay, P.-E.; Ramirez-Ruiz, Enrico
2016-02-01
We observed a sample of 10 white dwarf candidates in the rich open cluster NGC 2323 (M50) with the Keck Low-Resolution Imaging Spectrometer. The spectroscopy shows eight to be DA white dwarfs, with six of these having high signal-to-noise ratio appropriate for our analysis. Two of these white dwarfs are consistent with singly evolved cluster membership, and both are high mass ˜1.07 M⊙, and give equivalent progenitor masses of 4.69 M⊙. To supplement these new high-mass white dwarfs and analyze the initial-final mass relation (IFMR), we also looked at 30 white dwarfs from publicly available data that are mostly all high-mass (≳ 0.9 M⊙). These original published data exhibited significant scatter, and to test if this scatter is true or simply the result of systematics, we have uniformly analyzed the white dwarf spectra and have adopted thorough photometric techniques to derive uniform cluster parameters for their parent clusters. The resulting IFMR scatter is significantly reduced, arguing that mass-loss rates are not stochastic in nature and that within the ranges of metallicity and mass analyzed in this work mass loss is not highly sensitive to variations in metallicity. Lastly, when adopting cluster ages based on Y2 isochrones, the slope of the high-mass IFMR remains steep and consistent with that found from intermediate-mass white dwarfs, giving a linear IFMR from progenitor masses between 3 and 6.5 M⊙. In contrast, when adopting the slightly younger cluster ages based on PARSEC isochrones, the high-mass IFMR has a moderate turnover near an initial mass of 4 M⊙. Based on observations with the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and NASA, was made possible by the generous financial support of the W.M. Keck Foundation.
Wide-field Precision Kinematics of the M87 Globular Cluster System
NASA Astrophysics Data System (ADS)
Strader, Jay; Romanowsky, Aaron J.; Brodie, Jean P.; Spitler, Lee R.; Beasley, Michael A.; Arnold, Jacob A.; Tamura, Naoyuki; Sharples, Ray M.; Arimoto, Nobuo
2011-12-01
We present the most extensive combined photometric and spectroscopic study to date of the enormous globular cluster (GC) system around M87, the central giant elliptical galaxy in the nearby Virgo Cluster. Using observations from DEIMOS and the Low Resolution Imaging Spectrometer at Keck, and Hectospec on the Multiple Mirror Telescope, we derive new, precise radial velocities for 451 GCs around M87, with projected radii from ~5 to 185 kpc. We combine these measurements with literature data for a total sample of 737 objects, which we use for a re-examination of the kinematics of the GC system of M87. The velocities are analyzed in the context of archival wide-field photometry and a novel Hubble Space Telescope catalog of half-light radii, which includes sizes for 344 spectroscopically confirmed clusters. We use this unique catalog to identify 18 new candidate ultracompact dwarfs and to help clarify the relationship between these objects and true GCs. We find much lower values for the outer velocity dispersion and rotation of the GC system than in earlier papers and also differ from previous work in seeing no evidence for a transition in the inner halo to a potential dominated by the Virgo Cluster, nor for a truncation of the stellar halo. We find little kinematical evidence for an intergalactic GC population. Aided by the precision of the new velocity measurements, we see significant evidence for kinematical substructure over a wide range of radii, indicating that M87 is in active assembly. A simple, scale-free analysis finds less dark matter within ~85 kpc than in other recent work, reducing the tension between X-ray and optical results. In general, out to a projected radius of ~150 kpc, our data are consistent with the notion that M87 is not dynamically coupled to the Virgo Cluster; the core of Virgo may be in the earliest stages of assembly.
Diagrammatic analysis of correlations in polymer fluids: Cluster diagrams via Edwards' field theory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morse, David C.
2006-10-15
Edwards' functional integral approach to the statistical mechanics of polymer liquids is amenable to a diagrammatic analysis in which free energies and correlation functions are expanded as infinite sums of Feynman diagrams. This analysis is shown to lead naturally to a perturbative cluster expansion that is closely related to the Mayer cluster expansion developed for molecular liquids by Chandler and co-workers. Expansion of the functional integral representation of the grand-canonical partition function yields a perturbation theory in which all quantities of interest are expressed as functionals of a monomer-monomer pair potential, as functionals of intramolecular correlation functions of non-interacting molecules,more » and as functions of molecular activities. In different variants of the theory, the pair potential may be either a bare or a screened potential. A series of topological reductions yields a renormalized diagrammatic expansion in which collective correlation functions are instead expressed diagrammatically as functionals of the true single-molecule correlation functions in the interacting fluid, and as functions of molecular number density. Similar renormalized expansions are also obtained for a collective Ornstein-Zernicke direct correlation function, and for intramolecular correlation functions. A concise discussion is given of the corresponding Mayer cluster expansion, and of the relationship between the Mayer and perturbative cluster expansions for liquids of flexible molecules. The application of the perturbative cluster expansion to coarse-grained models of dense multi-component polymer liquids is discussed, and a justification is given for the use of a loop expansion. As an example, the formalism is used to derive a new expression for the wave-number dependent direct correlation function and recover known expressions for the intramolecular two-point correlation function to first-order in a renormalized loop expansion for coarse-grained models of binary homopolymer blends and diblock copolymer melts.« less
Phylogenetic Relationships of Citrus and Its Relatives Based on matK Gene Sequences
Penjor, Tshering; Uehara, Miki; Ide, Manami; Matsumoto, Natsumi; Matsumoto, Ryoji
2013-01-01
The genus Citrus includes mandarin, orange, lemon, grapefruit and lime, which have high economic and nutritional value. The family Rutaceae can be divided into 7 subfamilies, including Aurantioideae. The genus Citrus belongs to the subfamily Aurantioideae. In this study, we sequenced the chloroplast matK genes of 135 accessions from 22 genera of Aurantioideae and analyzed them phylogenetically. Our study includes many accessions that have not been examined in other studies. The subfamily Aurantioideae has been classified into 2 tribes, Clauseneae and Citreae, and our current molecular analysis clearly discriminate Citreae from Clauseneae by using only 1 chloroplast DNA sequence. Our study confirms previous observations on the molecular phylogeny of Aurantioideae in many aspects. However, we have provided novel information on these genetic relationships. For example, inconsistent with the previous observation, and consistent with our preliminary study using the chloroplast rbcL genes, our analysis showed that Feroniella oblata is not nested in Citrus species and is closely related with Feronia limonia. Furthermore, we have shown that Murraya paniculata is similar to Merrillia caloxylon and is dissimilar to Murraya koenigii. We found that “true citrus fruit trees” could be divided into 2 subclusters. One subcluster included Citrus, Fortunella, and Poncirus, while the other cluster included Microcitrus and Eremocitrus. Compared to previous studies, our current study is the most extensive phylogenetic study of Citrus species since it includes 93 accessions. The results indicate that Citrus species can be classified into 3 clusters: a citron cluster, a pummelo cluster, and a mandarin cluster. Although most mandarin accessions belonged to the mandarin cluster, we found some exceptions. We also obtained the information on the genetic background of various species of acid citrus grown in Japan. Because the genus Citrus contains many important accessions, we have comprehensively discussed the classification of this genus. PMID:23638116
NASA Astrophysics Data System (ADS)
Ghita, Adrian; Matousek, Pavel; Stone, Nick
2018-02-01
Our work focuses on the development of a medical Raman spectroscopy based platform to non-invasively detect and determine in-vivo molecular information deep inside biological tissues by monitoring the chemical composition of breast calcifications. The ultimate goal is to replace a needle biopsy which typically follows the detection of an abnormality in mammographic images. Here we report the non-invasive detection of calcium oxalate monohydrate in tissue through 40 mm of phantom tissues using our recently developed advanced Raman instrument complementing our previous detection of calcium hydroxyapatite through this thickness of tissue. The ability to detect these two key types of calcifications opens avenues for the development of non-invasive in-vivo breast cancer diagnostic tool in the future.
[Visual field progression in glaucoma: cluster analysis].
Bresson-Dumont, H; Hatton, J; Foucher, J; Fonteneau, M
2012-11-01
Visual field progression analysis is one of the key points in glaucoma monitoring, but distinction between true progression and random fluctuation is sometimes difficult. There are several different algorithms but no real consensus for detecting visual field progression. The trend analysis of global indices (MD, sLV) may miss localized deficits or be affected by media opacities. Conversely, point-by-point analysis makes progression difficult to differentiate from physiological variability, particularly when the sensitivity of a point is already low. The goal of our study was to analyse visual field progression with the EyeSuite™ Octopus Perimetry Clusters algorithm in patients with no significant changes in global indices or worsening of the analysis of pointwise linear regression. We analyzed the visual fields of 162 eyes (100 patients - 58 women, 42 men, average age 66.8 ± 10.91) with ocular hypertension or glaucoma. For inclusion, at least six reliable visual fields per eye were required, and the trend analysis (EyeSuite™ Perimetry) of visual field global indices (MD and SLV), could show no significant progression. The analysis of changes in cluster mode was then performed. In a second step, eyes with statistically significant worsening of at least one of their clusters were analyzed point-by-point with the Octopus Field Analysis (OFA). Fifty four eyes (33.33%) had a significant worsening in some clusters, while their global indices remained stable over time. In this group of patients, more advanced glaucoma was present than in stable group (MD 6.41 dB vs. 2.87); 64.82% (35/54) of those eyes in which the clusters progressed, however, had no statistically significant change in the trend analysis by pointwise linear regression. Most software algorithms for analyzing visual field progression are essentially trend analyses of global indices, or point-by-point linear regression. This study shows the potential role of analysis by clusters trend. However, for best results, it is preferable to compare the analyses of several tests in combination with morphologic exam. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
2002-01-01
Most of southeastern China has been covered by a thick greyish shroud of aerosol pollution over the last few weeks. The smog is so thick it is difficult to see the surface in some regions of this scene, acquired on January 7, 2002. The city of Hong Kong is the large brown cluster of pixels toward the lower lefthand corner of the image (indicated by the faint black box). The island of Taiwan, due east of mainland China, is also blanketed by the smog. This true-color image was captured by the Moderate-resolution Imaging Spectroradiometer (MODIS) sensor, flying aboard NASA's Terra satellite. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC
Pfliegler, W P; Sipiczki, M
2016-12-01
Simple and efficient genotyping methods are widely used to assess the diversity of a large number of microbial strains, e.g. wine yeasts isolated from a specific geographical area or a vintage. Such methods are often also the first to be applied, to decrease the number of strains deemed interesting for a more time-consuming physiological characterization. Here, we aimed to use a physiologically characterized strain collection of 69 Saccharomyces cerevisiae strains from Hungarian wine regions to determine whether geographical origin or physiological similarity can be recovered by clustering the strains with one or two simultaneously used variations of interdelta genotyping. Our results indicate that although a detailed clustering with high resolution can be achieved with this method, the clustering of strains is largely contrasting when different primer sets are used and it does not recover geographical or physiological groups. Genotyping is routinely used for assessing the diversity of a large number of isolates/strains of a single species, e.g. a collection of wine yeasts. We tested the efficiency of interdelta genotyping on a collection of Saccharomyces wine yeasts from four wine regions of Hungary that was previously characterized physiologically. Interdelta fingerprinting recovered neither physiological nor geographical similarities, and in addition, the two different primer pairs widely used for this method showed conflicting and barely comparable results. Thus, this method does not necessarily represent the true diversity of a strain collection, but detailed clustering may be achieved by the combined use of primer sets. © 2016 The Society for Applied Microbiology.
Quantifying the abundance of faint, low-redshift satellite galaxies in the COSMOS survey
NASA Astrophysics Data System (ADS)
Xi, ChengYu; Taylor, James E.; Massey, Richard J.; Rhodes, Jason; Koekemoer, Anton; Salvato, Mara
2018-06-01
Faint dwarf satellite galaxies are important as tracers of small-scale structure, but remain poorly characterized outside the Local Group, due to the difficulty of identifying them consistently at larger distances. We review a recently proposed method for estimating the average satellite population around a given sample of nearby bright galaxies, using a combination of size and magnitude cuts (to select low-redshift dwarf galaxies preferentially) and clustering measurements (to estimate the fraction of true satellites in the cut sample). We test this method using the high-precision photometric redshift catalog of the COSMOS survey, exploring the effect of specific cuts on the clustering signal. The most effective of the size-magnitude cuts considered recover the clustering signal around low-redshift primaries (z < 0.15) with about two-thirds of the signal and 80% of the signal-to-noise ratio obtainable using the full COSMOS photometric redshifts. These cuts are also fairly efficient, with more than one third of the selected objects being clustered satellites. We conclude that structural selection represents a useful tool in characterizing dwarf populations to fainter magnitudes and/or over larger areas than are feasible with spectroscopic surveys. In reviewing the low-redshift content of the COSMOS field, we also note the existence of several dozen objects that appear resolved or partially resolved in the HST imaging, and are confirmed to be local (at distances of ˜250 Mpc or less) by their photometric or spectroscopic redshifts. This underlines the potential for future space-based surveys to reveal local populations of intrinsically faint galaxies through imaging alone.
Surface EMG decomposition based on K-means clustering and convolution kernel compensation.
Ning, Yong; Zhu, Xiangjun; Zhu, Shanan; Zhang, Yingchun
2015-03-01
A new approach has been developed by combining the K-mean clustering (KMC) method and a modified convolution kernel compensation (CKC) method for multichannel surface electromyogram (EMG) decomposition. The KMC method was first utilized to cluster vectors of observations at different time instants and then estimate the initial innervation pulse train (IPT). The CKC method, modified with a novel multistep iterative process, was conducted to update the estimated IPT. The performance of the proposed K-means clustering-Modified CKC (KmCKC) approach was evaluated by reconstructing IPTs from both simulated and experimental surface EMG signals. The KmCKC approach successfully reconstructed all 10 IPTs from the simulated surface EMG signals with true positive rates (TPR) of over 90% with a low signal-to-noise ratio (SNR) of -10 dB. More than 10 motor units were also successfully extracted from the 64-channel experimental surface EMG signals of the first dorsal interosseous (FDI) muscles when a contraction force was held at 8 N by using the KmCKC approach. A "two-source" test was further conducted with 64-channel surface EMG signals. The high percentage of common MUs and common pulses (over 92% at all force levels) between the IPTs reconstructed from the two independent groups of surface EMG signals demonstrates the reliability and capability of the proposed KmCKC approach in multichannel surface EMG decomposition. Results from both simulated and experimental data are consistent and confirm that the proposed KmCKC approach can successfully reconstruct IPTs with high accuracy at different levels of contraction.
Solar Twins and the Barium Puzzle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, Arumalla B. S.; Lambert, David L., E-mail: bala@astro.as.utexas.edu
Several abundance analyses of Galactic open clusters (OCs) have shown a tendency for Ba but not for other heavy elements (La−Sm) to increase sharply with decreasing age such that Ba was claimed to reach [Ba/Fe] ≃ +0.6 in the youngest clusters (ages < 100 Myr) rising from [Ba/Fe] = 0.00 dex in solar-age clusters. Within the formulation of the s -process, the difficulty to replicate higher Ba abundance and normal La−Sm abundances in young clusters is known as the barium puzzle. Here, we investigate the barium puzzle using extremely high-resolution and high signal-to-noise spectra of 24 solar twins and measuredmore » the heavy elements Ba, La, Ce, Nd, and Sm with a precision of 0.03 dex. We demonstrate that the enhanced Ba ii relative to La−Sm seen among solar twins, stellar associations, and OCs at young ages (<100 Myr) is unrelated to aspects of stellar nucleosynthesis but has resulted from overestimation of Ba by standard methods of LTE abundance analysis in which the microturbulence derived from the Fe lines formed deep in the photosphere is insufficient to represent the true line broadening imposed on Ba ii lines by the upper photospheric layers from where the Ba ii lines emerge. Because the young stars have relatively active photospheres, Ba overabundances most likely result from the adoption of a too low value of microturbulence in the spectrum synthesis of the strong Ba ii lines but the change of microturbulence in the upper photosphere has only a minor affect on La−Sm abundances measured from the weak lines.« less
Clustering of cardiovascular risk factors in a middle-income country: a call for urgency.
Selvarajah, Sharmini; Haniff, Jamaiyah; Kaur, Gurpreet; Hiong, Tee Guat; Cheong, Kee Chee; Lim, Chiao Mei; Bots, Michiel L
2013-04-01
This study aimed to estimate the prevalence of cardiovascular risk factors and its clustering. The findings are to help shape the Malaysian future healthcare planning for cardiovascular disease prevention and management. Data from a nationally representative cross-sectional survey was used. The survey was conducted via a face-to-face interview using a standardised questionnaire. A total of 37,906 eligible participants aged 18 years and older was identified, of whom 34,505 (91%) participated. Focus was on hypertension, hyperglycaemia (diabetes and impaired fasting glucose), hypercholesterolaemia and central obesity. Overall, 63% (95% confidence limits 62, 65%) of the participants had at least one cardiovascular risk factor, 33% (32, 35%) had two or more and 14% (12, 15%) had three risk factors or more. The prevalence of hypertension, hyperglycaemia, hypercholesterolaemia and central obesity were 38%, 15%, 24% and 37%, respectively. Women were more likely to have a higher number of cardiovascular risk factors for most age groups; adjusted odds ratios ranging from 1.1 (0.91, 1.32) to 1.26 (1.12, 1.43) for the presence of one risk factor and 1.07 (0.91, 1.32) to 2.00 (1.78, 2.25) for two or more risk factors. Cardiovascular risk-factor clustering provides a clear impression of the true burden of cardiovascular disease risk in the population. Women displayed higher prevalence and a younger age shift in clustering was seen. These findings signal the presence of a cardiovascular epidemic in an upcoming middle-income country and provide evidence that drastic measures have to be taken to safeguard the health of the nation.
Solar Twins and the Barium Puzzle
NASA Astrophysics Data System (ADS)
Reddy, Arumalla B. S.; Lambert, David L.
2017-08-01
Several abundance analyses of Galactic open clusters (OCs) have shown a tendency for Ba but not for other heavy elements (La-Sm) to increase sharply with decreasing age such that Ba was claimed to reach [Ba/Fe] ≃ +0.6 in the youngest clusters (ages < 100 Myr) rising from [Ba/Fe] = 0.00 dex in solar-age clusters. Within the formulation of the s-process, the difficulty to replicate higher Ba abundance and normal La-Sm abundances in young clusters is known as the barium puzzle. Here, we investigate the barium puzzle using extremely high-resolution and high signal-to-noise spectra of 24 solar twins and measured the heavy elements Ba, La, Ce, Nd, and Sm with a precision of 0.03 dex. We demonstrate that the enhanced Ba II relative to La-Sm seen among solar twins, stellar associations, and OCs at young ages (<100 Myr) is unrelated to aspects of stellar nucleosynthesis but has resulted from overestimation of Ba by standard methods of LTE abundance analysis in which the microturbulence derived from the Fe lines formed deep in the photosphere is insufficient to represent the true line broadening imposed on Ba II lines by the upper photospheric layers from where the Ba II lines emerge. Because the young stars have relatively active photospheres, Ba overabundances most likely result from the adoption of a too low value of microturbulence in the spectrum synthesis of the strong Ba II lines but the change of microturbulence in the upper photosphere has only a minor affect on La-Sm abundances measured from the weak lines.
Makeev, Andrey; Clajus, Martin; Snyder, Scott; Wang, Xiaolang; Glick, Stephen J.
2015-01-01
Abstract. Semiconductor photon-counting detectors based on high atomic number, high density materials [cadmium zinc telluride (CZT)/cadmium telluride (CdTe)] for x-ray computed tomography (CT) provide advantages over conventional energy-integrating detectors, including reduced electronic and Swank noise, wider dynamic range, capability of spectral CT, and improved signal-to-noise ratio. Certain CT applications require high spatial resolution. In breast CT, for example, visualization of microcalcifications and assessment of tumor microvasculature after contrast enhancement require resolution on the order of 100 μm. A straightforward approach to increasing spatial resolution of pixellated CZT-based radiation detectors by merely decreasing the pixel size leads to two problems: (1) fabricating circuitry with small pixels becomes costly and (2) inter-pixel charge spreading can obviate any improvement in spatial resolution. We have used computer simulations to investigate position estimation algorithms that utilize charge sharing to achieve subpixel position resolution. To study these algorithms, we model a simple detector geometry with a 5×5 array of 200 μm pixels, and use a conditional probability function to model charge transport in CZT. We used COMSOL finite element method software to map the distribution of charge pulses and the Monte Carlo package PENELOPE for simulating fluorescent radiation. Performance of two x-ray interaction position estimation algorithms was evaluated: the method of maximum-likelihood estimation and a fast, practical algorithm that can be implemented in a readout application-specific integrated circuit and allows for identification of a quadrant of the pixel in which the interaction occurred. Both methods demonstrate good subpixel resolution; however, their actual efficiency is limited by the presence of fluorescent K-escape photons. Current experimental breast CT systems typically use detectors with a pixel size of 194 μm, with 2×2 binning during the acquisition giving an effective pixel size of 388 μm. Thus, it would be expected that the position estimate accuracy reported in this study would improve detection and visualization of microcalcifications as compared to that with conventional detectors. PMID:26158095
Makeev, Andrey; Clajus, Martin; Snyder, Scott; Wang, Xiaolang; Glick, Stephen J
2015-04-01
Semiconductor photon-counting detectors based on high atomic number, high density materials [cadmium zinc telluride (CZT)/cadmium telluride (CdTe)] for x-ray computed tomography (CT) provide advantages over conventional energy-integrating detectors, including reduced electronic and Swank noise, wider dynamic range, capability of spectral CT, and improved signal-to-noise ratio. Certain CT applications require high spatial resolution. In breast CT, for example, visualization of microcalcifications and assessment of tumor microvasculature after contrast enhancement require resolution on the order of [Formula: see text]. A straightforward approach to increasing spatial resolution of pixellated CZT-based radiation detectors by merely decreasing the pixel size leads to two problems: (1) fabricating circuitry with small pixels becomes costly and (2) inter-pixel charge spreading can obviate any improvement in spatial resolution. We have used computer simulations to investigate position estimation algorithms that utilize charge sharing to achieve subpixel position resolution. To study these algorithms, we model a simple detector geometry with a [Formula: see text] array of [Formula: see text] pixels, and use a conditional probability function to model charge transport in CZT. We used COMSOL finite element method software to map the distribution of charge pulses and the Monte Carlo package PENELOPE for simulating fluorescent radiation. Performance of two x-ray interaction position estimation algorithms was evaluated: the method of maximum-likelihood estimation and a fast, practical algorithm that can be implemented in a readout application-specific integrated circuit and allows for identification of a quadrant of the pixel in which the interaction occurred. Both methods demonstrate good subpixel resolution; however, their actual efficiency is limited by the presence of fluorescent [Formula: see text]-escape photons. Current experimental breast CT systems typically use detectors with a pixel size of [Formula: see text], with [Formula: see text] binning during the acquisition giving an effective pixel size of [Formula: see text]. Thus, it would be expected that the position estimate accuracy reported in this study would improve detection and visualization of microcalcifications as compared to that with conventional detectors.
NASA Astrophysics Data System (ADS)
Cockmartin, L.; Marshall, N. W.; Zhang, G.; Lemmens, K.; Shaheen, E.; Van Ongeval, C.; Fredenberg, E.; Dance, D. R.; Salvagnini, E.; Michielsen, K.; Bosmans, H.
2017-02-01
This paper introduces and applies a structured phantom with inserted target objects for the comparison of detection performance of digital breast tomosynthesis (DBT) against 2D full field digital mammography (FFDM). The phantom consists of a 48 mm thick breast-shaped polymethyl methacrylate (PMMA) container filled with water and PMMA spheres of different diameters. Three-dimensionally (3D) printed spiculated masses (diameter range: 3.8-9.7 mm) and non-spiculated masses (1.6-6.2 mm) along with microcalcifications (90-250 µm) were inserted as targets. Reproducibility of the phantom application was studied on a single system using 30 acquisitions. Next, the phantom was evaluated on five different combined FFDM & DBT systems and target detection was compared for FFDM and DBT modes. Ten phantom images in both FFDM and DBT modes were acquired on these 5 systems using automatic exposure control. Five readers evaluated target detectability. Images were read with the four-alternative forced-choice (4-AFC) paradigm, with always one segment including a target and 3 normal background segments. The percentage of correct responses (PC) was assessed based on 10 trials of each reader for each object type, size and imaging modality. Additionally, detection threshold diameters at 62.5 PC were assessed via non-linear regression fitting of the psychometric curve. The reproducibility study showed no significant differences in PC values. Evaluation of target detection in FFDM showed that microcalcification detection thresholds ranged between 110 and 118 µm and were similar compared to the detection in DBT (range of 106-158 µm). In DBT, detection of both mass types increased significantly (p = 0.0001 and p = 0.0002 for non-spiculated and spiculated masses respectively) compared to FFDM, achieving almost 100% detection for all spiculated mass diameters. In conclusion, a structured phantom with inserted targets was able to show evidence for detectability differences between FFDM and DBT modes for five commercial systems. This phantom has potential for application in task-based assessment at acceptance and commissioning testing of DBT systems.
McGarvey, Richard; Burch, Paul; Matthews, Janet M
2016-01-01
Natural populations of plants and animals spatially cluster because (1) suitable habitat is patchy, and (2) within suitable habitat, individuals aggregate further into clusters of higher density. We compare the precision of random and systematic field sampling survey designs under these two processes of species clustering. Second, we evaluate the performance of 13 estimators for the variance of the sample mean from a systematic survey. Replicated simulated surveys, as counts from 100 transects, allocated either randomly or systematically within the study region, were used to estimate population density in six spatial point populations including habitat patches and Matérn circular clustered aggregations of organisms, together and in combination. The standard one-start aligned systematic survey design, a uniform 10 x 10 grid of transects, was much more precise. Variances of the 10 000 replicated systematic survey mean densities were one-third to one-fifth of those from randomly allocated transects, implying transect sample sizes giving equivalent precision by random survey would need to be three to five times larger. Organisms being restricted to patches of habitat was alone sufficient to yield this precision advantage for the systematic design. But this improved precision for systematic sampling in clustered populations is underestimated by standard variance estimators used to compute confidence intervals. True variance for the survey sample mean was computed from the variance of 10 000 simulated survey mean estimates. Testing 10 published and three newly proposed variance estimators, the two variance estimators (v) that corrected for inter-transect correlation (ν₈ and ν(W)) were the most accurate and also the most precise in clustered populations. These greatly outperformed the two "post-stratification" variance estimators (ν₂ and ν₃) that are now more commonly applied in systematic surveys. Similar variance estimator performance rankings were found with a second differently generated set of spatial point populations, ν₈ and ν(W) again being the best performers in the longer-range autocorrelated populations. However, no systematic variance estimators tested were free from bias. On balance, systematic designs bring more narrow confidence intervals in clustered populations, while random designs permit unbiased estimates of (often wider) confidence interval. The search continues for better estimators of sampling variance for the systematic survey mean.
NASA Astrophysics Data System (ADS)
Kaur, Arshdeep; Chopra, Sahila; Gupta, Raj K.
2014-03-01
The dynamical cluster-decay model (DCM), an extended version of the preformed cluster model (PCM) for ground-state (T =0) decays, is applied to study the decay of the proton-rich compound nucleus Ce124* formed in the S32 + Mo92 reaction at an above-barrier beam energy of 150 MeV. Application of the statistical code pace4 to experimental data shows large deviations in all cases of proton clusters' (2p, 3p, and 4p) evaporation residue (ER) and the non-α nucleus Be6 intermediate mass fragment (IMF). Furthermore, the α-nucleus Be8 decay is not observed in this experiment (not even the upper limit is given). Using the DCM, with effects of deformations up to hexadecapole and "compact" orientations included, for the best-fitted cross sections of 2p and 3p ERs and of Li5 and Be6 IMFs, the relative cross section of Be8 is found to be more than that of Be6, possibly due to the α-nucleus structure of Be8. The same is shown to be true for C12 versus C10, i.e., α-nuclei clusters are populated strongly relative to non-α clusters, similar to what was predicted by one of us (R.K.G.) et al. [S. Kumar, D. Bir, and R. K. Gupta, Phys. Rev. C 51, 1762 (1995), 10.1103/PhysRevC.51.1762] for ground-state decays of such nuclei and the decay of Ba116* formed in the Ni58 + Ni58 reaction at various compound nucleus excitation energies [R. K. Gupta et al., J. Phys. G: Nucl. Part. Phys. 32, 345 (2006), 10.1088/0954-3899/32/3/009]. The only parameter of the DCM is the neck-length ΔR, related to the "barrier-lowering" parameter. The compound nucleus formation probability and "barrier-lowering/-modification" effects are analyzed, and the role of varying the deformations of Be6 and/or Be8 nuclei on relative cross sections is studied, since the measured deformations are not available. The ones used here are from relativistic mean-field calculations [β2(6Be )=-0.087 and β2(8Be)=-0.094]. Calculations are also presented for a beam energy of 140 MeV, supporting the above result.
NASA Astrophysics Data System (ADS)
2005-03-01
Summary Super star clusters are groups of hundreds of thousands of very young stars packed into an unbelievably small volume. They represent the most extreme environments in which stars and planets can form. Until now, super star clusters were only known to exist very far away, mostly in pairs or groups of interacting galaxies. Now, however, a team of European astronomers [1] have used ESO's telescopes to uncover such a monster object within our own Galaxy, the Milky Way, almost, but not quite, in our own backyard! The newly found massive structure is hidden behind a large cloud of dust and gas and this is why it took so long to unveil its true nature. It is known as "Westerlund 1" and is a thousand times closer than any other super star cluster known so far. It is close enough that astronomers may now probe its structure in some detail. Westerlund 1 contains hundreds of very massive stars, some shining with a brilliance of almost one million suns and some two-thousand times larger than the Sun (as large as the orbit of Saturn)! Indeed, if the Sun were located at the heart of this remarkable cluster, our sky would be full of hundreds of stars as bright as the full Moon. Westerlund 1 is a most unique natural laboratory for the study of extreme stellar physics, helping astronomers to find out how the most massive stars in our Galaxy live and die. From their observations, the astronomers conclude that this extreme cluster most probably contains no less than 100,000 times the mass of the Sun, and all of its stars are located within a region less than 6 light-years across. Westerlund 1 thus appears to be the most massive compact young cluster yet identified in the Milky Way Galaxy. PR Photo 09a/05: The Super Star Cluster Westerlund 1 (2.2m MPG/ESO + WFI) PR Photo 09b/05: Properties of Young Massive Clusters Super Star Clusters Stars are generally born in small groups, mostly in so-called "open clusters" that typically contain a few hundred stars. From a wide range of observations, astronomers infer that the Sun itself was born in one such cluster, some 4,500 million years ago. In some active ("starburst") galaxies, scientists have observed violent episodes of star formation (see, for example, ESO Press Photo 31/04), leading to the development of super star clusters, each containing several million stars. Such events were obviously common during the Milky Way's childhood, more than 12,000 million years ago: the many galactic globular clusters - which are nearly as old as our Galaxy (e.g. ESO PR 20/04) - are indeed thought to be the remnants of early super star clusters. All super star clusters so far observed in starburst galaxies are very distant. It is not possible to distinguish their individual stars, even with the most advanced technology. This dramatically complicates their study and astronomers have therefore long been eager to find such clusters in our neighbourhood in order to probe their structure in much more detail. Now, a team of European astronomers [1] has finally succeeded in doing so, using several of ESO's telescopes at the La Silla observatory (Chile). Westerlund 1 ESO PR Photo 09a/05 ESO PR Photo 09a/05 The Super Star Cluster Westerlund 1 (2.2m MPG/ESO + WFI) [Preview - JPEG: 400 x 472 pix - 58k] [Normal - JPEG: 800 x 943 pix - 986k] [Full Res - JPEG: 1261 x 1486 pix - 2.4M] Caption: ESO PR Photo 09a/05 is a composite image of the super star cluster "Westerlund 1" from 2.2-m MPG/ESO Wide-Field Imager (WFI) observations. The image covers a 5 x 5 arcmin sky region and is based on observations made in the V-band (550 nm, 2 min exposure time, associated to the blue channel), R-band (650nm, 1 min, green channel) and I-band (784nm, 18 sec, red channel). Only the central CCD of WFI was used, as the entire cluster fits comfortably inside it. The foreground stars appear blue, while the hot massive members of the cluster look orange, and the cool massive ones come out red. The open cluster Westerlund 1 is located in the Southern constellation Ara (the Altar). It was discovered in 1961 from Australia by Swedish astronomer Bengt Westerlund, who later moved from there to become ESO Director in Chile (1970 - 74). This cluster is behind a huge interstellar cloud of gas and dust, which blocks most of its visible light. The dimming factor is more than 100,000 - and this is why it has taken so long to uncover the true nature of this particular cluster. In 2001, the team of astronomers identified more than a dozen extremely hot and peculiar massive stars in the cluster, so-called "Wolf-Rayet" stars. They have since studied Westerlund 1 extensively with various ESO telescopes. They used images from the Wide Field Imager (WFI) attached to the 2.2-m ESO/MPG as well as from the SUperb Seeing Imager 2 (SuSI2) camera on the ESO 3.5-m New Technology Telescope (NTT). From these observations, they were able to identify about 200 cluster member stars. To establish the true nature of these stars, the astronomers then performed spectroscopic observations of about one quarter of them. For this, they used the Boller & Chivens spectrograph on the ESO 1.52-m telescope and the ESO Multi-Mode Instrument (EMMI) on the NTT. An Exotic Zoo These observations have revealed a large population of very bright and massive, quite extreme stars. Some would fill the solar system space within the orbit of Saturn (about 2,000 times larger than the Sun!), others are as bright as a million Suns. Westerlund 1 is obviously a fantastic stellar zoo, with a most exotic population and a true astronomical bonanza. All stars identified are evolved and very massive, spanning the full range of stellar oddities from Wolf-Rayet stars, OB supergiants, Yellow Hypergiants (nearly as bright as a million Suns) and Luminous Blue Variables (similar to the exceptional Eta Carinae object - see ESO PR 31/03). All stars so far analysed in Westerlund 1 weigh at least 30-40 times more than the Sun. Because such stars have a rather short life - astronomically speaking - Westerlund 1 must be very young. The astronomers determine an age somewhere between 3.5 and 5 million years. So, Westerlund 1 is clearly a "newborn" cluster in our Galaxy! The Most Massive Cluster ESO PR Photo 09b/05 ESO PR Photo 09b/05 Properties of Young Massive Clusters [Preview - JPEG: 400 x 511 pix - 20k] [Normal - JPEG: 800 x 1021 pix - 122k] Caption: ESO PR Photo 09b/05 shows the properties of young massive clusters in our Galaxy and in the Large Magellanic Clouds, as well as of Super Star Clusters in star-forming galaxies. The diagram shows the mass and radius of these clusters and also the position of Westerlund 1 (indicated Wd 1). Westerlund 1 is incredibly rich in monster stars - just as one example, it contains as many Yellow Hypergiants as were hitherto known in the entire Milky Way! "If the Sun were located at the heart of Westerlund 1, the sky would be full of stars, many of them brighter than the full Moon", comments Ignacio Negueruela of the Universidad de Alicante in Spain and member of the team. The large quantity of very massive stars implies that Westerlund 1 must contain a huge number of stars. "In our Galaxy, explains Simon Clark of the University College London (UK) and one of the authors of this study, "there are more than 100 solar-like stars for every star weighing 10 times as much as the Sun. The fact that we see hundreds of massive stars in Westerlund 1 means that it probably contains close to half a million stars, but most of these are not bright enough to peer through the obscuring cloud of gas and dust". This is ten times more than any other known young clusterin the Milky Way. Westerlund 1 is presumably much more massive than the dense clusters of heavy stars present in the central region of our Galaxy, like the Arches and Quintuplet clusters. Further deep infrared observations will be required to confirm this. This super star cluster now provides astronomers with a unique perspective towards one of the most extreme environments in the Universe. Westerlund 1 will certainly provide new opportunities in the long-standing quest for more and finer details about how stars, and especially massive ones, do form. ... and the Most Dense The large number of stars in Westerlund 1 was not the only surprise awaiting Clark and his colleagues. From their observations, the team members also found that all these stars are packed into an amazingly small volume of space, indeed less than 6 light-years across. In fact, this is more or less comparable to the 4 light-year distance to the star nearest to the Sun, Proxima Centauri! It is incredible: the concentration in Westerlund 1 is so high that the mean separation between stars is quite similar to the extent of the Solar System. "With so many stars in such a small volume, some of them may collide", envisages Simon Clark. "This could lead to the formation of an intermediate-mass black hole more massive than 100 solar masses. It may well be that such a monster has already formed at the core of Westerlund 1." The huge population of massive stars in Westerlund 1 suggests that it will have a very significant impact on its surroundings. The cluster contains so many massive stars that in a time span of less than 40 million years, it will be the site of more than 1,500 supernovae. A gigantic firework that may drive a fountain of galactic material! Because Westerlund 1 is at a distance of only about 10,000 light-years, high-resolution cameras such as NAOS/CONICA on ESO's Very Large Telescope can resolve its individual stars. Such observations are now starting to reveal smaller stars in Westerlund 1, including some that are less massive than the Sun. Astronomers will thus soon be able to study this exotic galactic zoo in great depth. More information The research presented in this ESO Press Release will soon appear in the leading research journal Astronomy and Astrophysics ("On the massive stellar population of the Super Star Cluster Westerlund 1" by J.S. Clark and colleagues). The PDF file is available at the A&A web site. A second paper ("Further Wolf-Rayet stars in the starburst cluster Westerlund 1", by Ignacio Negueruela and Simon Clark) will also soon be published in Astronomy and Astrophysics. It is available as astro-ph/0503303. A Spanish press release issued by Universidad de Alicante is available on the web site of Ignacio Negueruela.
Clark, David J; Fondrie, William E; Liao, Zhongping; Hanson, Phyllis I; Fulton, Amy; Mao, Li; Yang, Austin J
2015-10-20
Exosomes are microvesicles of endocytic origin constitutively released by multiple cell types into the extracellular environment. With evidence that exosomes can be detected in the blood of patients with various malignancies, the development of a platform that uses exosomes as a diagnostic tool has been proposed. However, it has been difficult to truly define the exosome proteome due to the challenge of discerning contaminant proteins that may be identified via mass spectrometry using various exosome enrichment strategies. To better define the exosome proteome in breast cancer, we incorporated a combination of Tandem-Mass-Tag (TMT) quantitative proteomics approach and Support Vector Machine (SVM) cluster analysis of three conditioned media derived fractions corresponding to a 10 000g cellular debris pellet, a 100 000g crude exosome pellet, and an Optiprep enriched exosome pellet. The quantitative analysis identified 2 179 proteins in all three fractions, with known exosomal cargo proteins displaying at least a 2-fold enrichment in the exosome fraction based on the TMT protein ratios. Employing SVM cluster analysis allowed for the classification 251 proteins as "true" exosomal cargo proteins. This study provides a robust and vigorous framework for the future development of using exosomes as a potential multiprotein marker phenotyping tool that could be useful in breast cancer diagnosis and monitoring disease progression.
Estimation of rank correlation for clustered data.
Rosner, Bernard; Glynn, Robert J
2017-06-30
It is well known that the sample correlation coefficient (R xy ) is the maximum likelihood estimator of the Pearson correlation (ρ xy ) for independent and identically distributed (i.i.d.) bivariate normal data. However, this is not true for ophthalmologic data where X (e.g., visual acuity) and Y (e.g., visual field) are available for each eye and there is positive intraclass correlation for both X and Y in fellow eyes. In this paper, we provide a regression-based approach for obtaining the maximum likelihood estimator of ρ xy for clustered data, which can be implemented using standard mixed effects model software. This method is also extended to allow for estimation of partial correlation by controlling both X and Y for a vector U_ of other covariates. In addition, these methods can be extended to allow for estimation of rank correlation for clustered data by (i) converting ranks of both X and Y to the probit scale, (ii) estimating the Pearson correlation between probit scores for X and Y, and (iii) using the relationship between Pearson and rank correlation for bivariate normally distributed data. The validity of the methods in finite-sized samples is supported by simulation studies. Finally, two examples from ophthalmology and analgesic abuse are used to illustrate the methods. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Liao, S J; Tan, M P; Chong, M C; Chua, Y P
2018-05-01
The effectiveness of pharmacological treatment may be limited in older persons. Several studies using Tai Chi or music therapy separately confirmed positive effects in the reduction of depressive symptoms. We conducted a cluster randomized controlled trial to evaluate the possible synergistic effect of combined music and Tai Chi on depressive symptoms. One hundred and seven older adults with mild to moderate depressive symptoms were recruited from Ya'an city. Fifty-five participants were cluster randomized to combined music and Tai Chi group for three months, while the other fifty-two individuals were randomized to the control group that entailed routine health education delivered monthly by community nurses. The primary outcome of depressive symptoms was measured with the Geriatric Depression Scale (GDS) at baseline and monthly for three months. At three-month follow-up, a statistically significant improvement in depressive symptoms was found in the intervention group compared with control group (F(3,315) = 69.661, P < 0.001). Following adjustments for socio-demographic data, the true effect of intervention on depressive symptoms was significant (F = 41.725, P < 0.01, η p 2 = 0.574). Combined music and Tai Chi reduced depressive symptoms among community-dwelling older persons. This represents an economically viable solution to the management of depression in highly populous developing nations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
de Gasperin, F.; Ogrean, G. A.; van Weeren, R. J.
We report that extended steep-spectrum radio emission in a galaxy cluster is usually associated with a recent merger. However, given the complex scenario of galaxy cluster mergers, many of the discovered sources hardly fit into the strict boundaries of a precise taxonomy. This is especially true for radio phoenixes that do not have very well defined observational criteria. Radio phoenixes are aged radio galaxy lobes whose emission is reactivated by compression or other mechanisms. Here in this paper, we present the detection of a radio phoenix close to the moment of its formation. The source is located in Abell 1033,more » a peculiar galaxy cluster which underwent a recent merger. To support our claim, we present unpublished Westerbork Synthesis Radio Telescope and Chandra observations together with archival data from the Very Large Array and the Sloan Digital Sky Survey. We discover the presence of two subclusters displaced along the N–S direction. The two subclusters probably underwent a recent merger which is the cause of a moderately perturbed X-ray brightness distribution. A steep-spectrum extended radio source very close to an active galactic nucleus (AGN) is proposed to be a newly born radio phoenix: the AGN lobes have been displaced/compressed by shocks formed during the merger event. This scenario explains the source location, morphology, spectral index, and brightness. Finally, we show evidence of a density discontinuity close to the radio phoenix and discuss the consequences of its presence.« less
Particle-hole symmetry in many-body theories of electron correlation
NASA Astrophysics Data System (ADS)
Kats, Daniel; Usvyat, Denis; Manby, Frederick R.
2018-06-01
Second-quantised creation and annihilation operators for fermionic particles anticommute, but the same is true for the creation and annihilation operators for holes. This introduces a symmetry into the quantum theory of fermions that is absent for bosons. In ab initio electronic structure theory, it is common to classify methods by the number of electrons for which the method returns exact results: for example Hartree-Fock theory is exact for one-electron systems, whereas coupled-cluster theory with single and double excitations is exact for two-electron systems. Here, we discuss the generalisation: methods based on approximate wavefunctions that are exact for n-particle systems are also exact for n-hole systems. Novel electron correlation methods that attempt to improve on the coupled-cluster framework sometimes retain this property, and sometimes lose it. Here, we argue for retaining particle-hole symmetry as a desirable design criterion of approximate electron correlation methods. Dispensing with it might lead to loss of n-representability of density matrices, and this in turn can lead to spurious long-range behaviour in the correlation energy.
A method for analyzing clustered interval-censored data based on Cox's model.
Kor, Chew-Teng; Cheng, Kuang-Fu; Chen, Yi-Hau
2013-02-28
Methods for analyzing interval-censored data are well established. Unfortunately, these methods are inappropriate for the studies with correlated data. In this paper, we focus on developing a method for analyzing clustered interval-censored data. Our method is based on Cox's proportional hazard model with piecewise-constant baseline hazard function. The correlation structure of the data can be modeled by using Clayton's copula or independence model with proper adjustment in the covariance estimation. We establish estimating equations for the regression parameters and baseline hazards (and a parameter in copula) simultaneously. Simulation results confirm that the point estimators follow a multivariate normal distribution, and our proposed variance estimations are reliable. In particular, we found that the approach with independence model worked well even when the true correlation model was derived from Clayton's copula. We applied our method to a family-based cohort study of pandemic H1N1 influenza in Taiwan during 2009-2010. Using the proposed method, we investigate the impact of vaccination and family contacts on the incidence of pH1N1 influenza. Copyright © 2012 John Wiley & Sons, Ltd.
Song, Zhongshu; Bakeer, Walid; Marshall, James W.; Yakasai, Ahmed A.; Khalid, Rozida Mohd; Collemare, Jerome; Skellam, Elizabeth; Tharreau, Didier; Lebrun, Marc-Henri; Lazarus, Colin M.; Bailey, Andrew M.; Simpson, Thomas J.
2015-01-01
The ACE1 and RAP1 genes from the avirulence signalling gene cluster of the rice blast fungus Magnaporthe oryzae were expressed in Aspergillus oryzae and M. oryzae itself. Expression of ACE1 alone produced a polyenyl pyrone (magnaporthepyrone), which is regioselectively epoxidised and hydrolysed to give different diols, 6 and 7, in the two host organisms. Analysis of the three introns present in ACE1 determined that A. oryzae does not process intron 2 correctly, while M. oryzae processes all introns correctly in both appressoria and mycelia. Co-expression of ACE1 and RAP1 in A. oryzae produced an amide 8 which is similar to the PKS-NRPS derived backbone of the cytochalasans. Biological testing on rice leaves showed that neither the diols 6 and 7, nor amide 8 was responsible for the observed ACE1 mediated avirulence, however, gene cluster analysis suggests that the true avirulence signalling compound may be a tyrosine-derived cytochalasan compound. PMID:29142718
NASA Technical Reports Server (NTRS)
Kelton, K. F.; Gangopadhyay, A. K.; Lee, G. W.; Hyers, R. W.; Rathz, T. J.; Rogers, J. R.; Robinson, M. B.; Schenk, T.; Simonet, V.
2003-01-01
Over fifty years ago, David Turnbull showed that the temperature of many metallic liquids could be decreased far below their equilibrium melting temperature before crystallization occurred. To explain those surprising results, Charles Frank hypothesized that the local structures of undercooled metallic liquids are different from those of crystal phases, containing a significant degree of icosahedral order that is incompatible with extended periodicity. Such structural differences must create a barrier to the formation crystal phases, explaining the observed undercooling behavior. If true, the nucleation from the liquid of phases with extended icosahedral order should be easier. Icosahedral order is often favored in small clusters, as observed recently in liquid-like clusters of pure Pb on the (111) surface of Si[3], for example. However, it has never been shown that an increasing preference for icosahedral phase formation can be directly linked with the development of icosahedral order in the undercooled liquid. Owing to the combination of very recent advances in levitation techniques and the availability of synchrotron x-ray and high flux neutron facilities, this is shown here.
NASA Technical Reports Server (NTRS)
Curreri, Peter A. (Technical Monitor); Kelton, K. F.; Gangopadhyay, A.; Lee, G. W.; Hyers, R. W.; Rathz, R. J.; Rogers, J.; Schenk, T.; Simonet, V.; Holland-Moritz, D.
2003-01-01
Over fifty years ago, David Turnbull showed that the temperature of many metallic liquids could be decreased far below their equilibrium melting temperature before crystallization occurred. To explain those surprising results, Charles Frank hypothesized that the local structures of undercooled metallic liquids are different from those of crystal phases, containing a significant degree of icosahedral order that is incompatible with extended periodicity. Such structural differences must create a barrier to the formation crystal phases, explaining the observed undercooling behavior. If true, the nucleation from the liquid of phases with extended icosahedral order should be easier. Icosahedral order is often favored in small clusters, as observed recently in liquid-like clusters of pure Pb on the (111) surface of Si, for example. However, it has never been shown that an increasing preference for icosahedral phase formation can be directly linked with the development of icosahedral order in the undercooled liquid. Owing to the combination of very recent advances in levitation techniques and the availability of synchrotron x-ray and high flux neutron facilities, this is shown here.
NASA Technical Reports Server (NTRS)
Kelton, K. F.; Gangopadhyay, A. K.; Lee, G. W.; Hyers, R. W.; Rathz, T. J.; Rogers, J. R.; Robinson, M. B.; Schenk, T.; Simonet, V.; Holland-Moritz, D.;
2002-01-01
Over fifty years ago, David Turnbull showed that the temperature of many metallic liquids could be decreased far below their equilibrium melting temperature before crystallization occurred. To explain those surprising results, Charles Frank hypothesized that the local structures of undercooled metallic liquids are different from those of crystal phases, containing a significant degree of icosahedral order that is incompatible with extended periodicity. Such structural differences must create a barrier to the formation crystal phases, explaining the observed undercooling behavior. If true, the nucleation from the liquid of phases with extended icosahedral order should be easier. Icosahedral order is often favored in small clusters, as observed recently in liquid-like clusters of pure Pb on the (111) surface of Si(3), for example. However, it has never been shown that an increasing preference for icosahedral phase formation can be directly linked with the development of icosahedral order in the undercooled liquid. Owing to the combination of very recent advances in levitation techniques and the availability of synchrotron X-ray and high flux neutron facilities.
Cannabinoids and hallucinogens for headache.
McGeeney, Brian E
2013-03-01
Hallucinogens and most cannabinoids are classified under schedule 1 of the Federal Controlled Substances Act 1970, along with heroin and ecstacy. Hence they cannot be prescribed by physicians, and by implication, have no accepted medical use with a high abuse potential. Despite their legal status, hallucinogens and cannabinoids are used by patients for relief of headache, helped by the growing number of American states that have legalized medical marijuana. Cannabinoids in particular have a long history of use in the abortive and prophylactic treatment of migraine before prohibition and are still used by patients as a migraine abortive in particular. Most practitioners are unaware of the prominence cannabis or "marijuana" once held in medical practice. Hallucinogens are being increasingly used by cluster headache patients outside of physician recommendation mainly to abort a cluster period and maintain quiescence for which there is considerable anecdotal success. The legal status of cannabinoids and hallucinogens has for a long time severely inhibited medical research, and there are still no blinded studies on headache subjects, from which we could assess true efficacy. © 2012 American Headache Society.
Manoharan, Sujatha C; Ramakrishnan, Swaminathan
2009-10-01
In this work, prediction of forced expiratory volume in pulmonary function test, carried out using spirometry and neural networks is presented. The pulmonary function data were recorded from volunteers using commercial available flow volume spirometer in standard acquisition protocol. The Radial Basis Function neural networks were used to predict forced expiratory volume in 1 s (FEV1) from the recorded flow volume curves. The optimal centres of the hidden layer of radial basis function were determined by k-means clustering algorithm. The performance of the neural network model was evaluated by computing their prediction error statistics of average value, standard deviation, root mean square and their correlation with the true data for normal, restrictive and obstructive cases. Results show that the adopted neural networks are capable of predicting FEV1 in both normal and abnormal cases. Prediction accuracy was more in obstructive abnormality when compared to restrictive cases. It appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.
A generalized Uhlenbeck and Beth formula for the third cluster coefficient
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsen, Sigurd Yves; Lassaut, Monique; Amaya-Tapia, Alejandro, E-mail: jano@icf.unam.mx
2016-11-15
Relatively recently (Amaya-Tapia et al., 2011), we presented a formula for the evaluation of the third Bose fugacity coefficient–leading to the third virial coefficient–in terms of three-body eigenphase shifts, for particles subject to repulsive forces. An analytical calculation for a 1-dim. model, for which the result is known, confirmed the validity of this approach. We now extend the formalism to particles with attractive forces, and therefore must allow for the possibility that the particles have bound states. We thus obtain a true generalization of the famous formula of Uhlenbeck and Beth (Uhlenbeck and Beth, 1936; Beth and Uhlenbeck, 1937) and ofmore » Gropper (Gropper, 1936, 1937) for the second virial. We illustrate our formalism by a calculation, in an adiabatic approximation, of the third cluster in one dimension, using McGuire’s model as in our previous paper, but with attractive forces. The inclusion of three-body bound states is trivial; taking into account states having asymptotically two particles bound, and one free, is not.« less
Screening and clustering of sparse regressions with finite non-Gaussian mixtures.
Zhang, Jian
2017-06-01
This article proposes a method to address the problem that can arise when covariates in a regression setting are not Gaussian, which may give rise to approximately mixture-distributed errors, or when a true mixture of regressions produced the data. The method begins with non-Gaussian mixture-based marginal variable screening, followed by fitting a full but relatively smaller mixture regression model to the selected data with help of a new penalization scheme. Under certain regularity conditions, the new screening procedure is shown to possess a sure screening property even when the population is heterogeneous. We further prove that there exists an elbow point in the associated scree plot which results in a consistent estimator of the set of active covariates in the model. By simulations, we demonstrate that the new procedure can substantially improve the performance of the existing procedures in the content of variable screening and data clustering. By applying the proposed procedure to motif data analysis in molecular biology, we demonstrate that the new method holds promise in practice. © 2016, The International Biometric Society.