Solution of multi-center molecular integrals of Slater-type orbitals
NASA Technical Reports Server (NTRS)
Tai, H.
1989-01-01
The troublesome multi-center molecular integrals of Slater-type orbitals (STO) in molecular physics calculations can be evaluated by using the Fourier transform and proper coupling of the two center exchange integrals. A numerical integration procedure is then readily rendered to the final expression in which the integrand consists of well known special functions of arguments containing the geometrical arrangement of the nuclear centers and the exponents of the atomic orbitals. A practical procedure was devised for the calculation of a general multi-center molecular integrals coupling arbitrary Slater-type orbitals. Symmetry relations and asymptotic conditions are discussed. Explicit expressions of three-center one-electron nuclear-attraction integrals and four-center two-electron repulsion integrals for STO of principal quantum number n=2 are listed. A few numerical results are given for the purpose of comparison.
Guseinov, Israfil I; Görgün, Nurşen Seçkin
2011-06-01
The electric field induced within a molecule by its electrons determines a whole series of important physical properties of the molecule. In particular, the values of the gradient of this field at the nuclei determine the interaction of their quadrupole moments with the electrons. Using unsymmetrical one-range addition theorems introduced by one of the authors, the sets of series expansion relations for multicenter electric field gradient integrals over Slater-type orbitals in terms of multicenter charge density expansion coefficients and two-center basic integrals are presented. The convergence of the series is tested by calculating concrete cases for different values of quantum numbers, parameters and locations of orbitals.
Guseinov, Israfil
2004-02-01
In this study, using complete orthonormal sets of Psi(alpha)-ETOs (where alpha=1, 0, -1, -2, ...) introduced by the author, a large number of series expansion formulae for the multicenter electronic attraction (EA), electric field (EF) and electric field gradient (EFG) integrals of the Yukawa-like screened Coulomb potentials (SCPs) is presented through the new central and noncentral potentials and the overlap integrals with the same screening constants. The final results obtained are valid for arbitrary locations of STOs and their parameters.
Goldberg, Howard S; Paterno, Marilyn D; Grundmeier, Robert W; Rocha, Beatriz H; Hoffman, Jeffrey M; Tham, Eric; Swietlik, Marguerite; Schaeffer, Molly H; Pabbathi, Deepika; Deakyne, Sara J; Kuppermann, Nathan; Dayan, Peter S
2016-03-01
To evaluate the architecture, integration requirements, and execution characteristics of a remote clinical decision support (CDS) service used in a multicenter clinical trial. The trial tested the efficacy of implementing brain injury prediction rules for children with minor blunt head trauma. We integrated the Epic(®) electronic health record (EHR) with the Enterprise Clinical Rules Service (ECRS), a web-based CDS service, at two emergency departments. Patterns of CDS review included either a delayed, near-real-time review, where the physician viewed CDS recommendations generated by the nursing assessment, or a real-time review, where the physician viewed recommendations generated by their own documentation. A backstopping, vendor-based CDS triggered with zero delay when no recommendation was available in the EHR from the web-service. We assessed the execution characteristics of the integrated system and the source of the generated recommendations viewed by physicians. The ECRS mean execution time was 0.74 ±0.72 s. Overall execution time was substantially different at the two sites, with mean total transaction times of 19.67 and 3.99 s. Of 1930 analyzed transactions from the two sites, 60% (310/521) of all physician documentation-initiated recommendations and 99% (1390/1409) of all nurse documentation-initiated recommendations originated from the remote web service. The remote CDS system was the source of recommendations in more than half of the real-time cases and virtually all the near-real-time cases. Comparisons are limited by allowable variation in user workflow and resolution of the EHR clock. With maturation and adoption of standards for CDS services, remote CDS shows promise to decrease time-to-trial for multicenter evaluations of candidate decision support interventions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Broberg, Craig S; Mitchell, Julie; Rehel, Silven; Grant, Andrew; Gianola, Ann; Beninato, Peter; Winter, Christiane; Verstappen, Amy; Valente, Anne Marie; Weiss, Joseph; Zaidi, Ali; Earing, Michael G; Cook, Stephen; Daniels, Curt; Webb, Gary; Khairy, Paul; Marelli, Ariane; Gurvitz, Michelle Z; Sahn, David J
2015-10-01
The adoption of electronic health records (EHR) has created an opportunity for multicenter data collection, yet the feasibility and reliability of this methodology is unknown. The aim of this study was to integrate EHR data into a homogeneous central repository specifically addressing the field of adult congenital heart disease (ACHD). Target data variables were proposed and prioritized by consensus of investigators at five target ACHD programs. Database analysts determined which variables were available within their institutions' EHR and stratified their accessibility, and results were compared between centers. Data for patients seen in a single calendar year were extracted to a uniform database and subsequently consolidated. From 415 proposed target variables, only 28 were available in discrete formats at all centers. For variables of highest priority, 16/28 (57%) were available at all four sites, but only 11% for those of high priority. Integration was neither simple nor straightforward. Coding schemes in use for congenital heart diagnoses varied and would require additional user input for accurate mapping. There was considerable variability in procedure reporting formats and medication schemes, often with center-specific modifications. Despite the challenges, the final acquisition included limited data on 2161 patients, and allowed for population analysis of race/ethnicity, defect complexity, and body morphometrics. Large-scale multicenter automated data acquisition from EHRs is feasible yet challenging. Obstacles stem from variability in data formats, coding schemes, and adoption of non-standard lists within each EHR. The success of large-scale multicenter ACHD research will require institution-specific data integration efforts. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Tug-of-war between classical and multicenter bonds in H-(Be)n-H species
NASA Astrophysics Data System (ADS)
Lundell, Katie A.; Boldyrev, Alexander I.
2018-05-01
Quantum chemical calculations were performed for beryllium homocatenated compounds [H-(Be)n-H]. Global minimum structures were found using machine searches (Coalescence Kick method) with density functional theory. Chemical bonding analysis was performed with the Adaptive Natural Density Partitioning method. It was found that H-(Be)2-H and H-(Be)3-H clusters are linear with classical two-center two-electron bonds, while for n > 3, three-dimensional structures are more stable with multicenter bonding. Thus, at n = 4, multicenter bonding wins the tug-of-war vs. the classical bonding.
Eisenstein, Eric L; Diener, Lawrence W; Nahm, Meredith; Weinfurt, Kevin P
2011-12-01
New technologies may be required to integrate the National Institutes of Health's Patient Reported Outcome Management Information System (PROMIS) into multi-center clinical trials. To better understand this need, we identified likely PROMIS reporting formats, developed a multi-center clinical trial process model, and identified gaps between current capabilities and those necessary for PROMIS. These results were evaluated by key trial constituencies. Issues reported by principal investigators fell into two categories: acceptance by key regulators and the scientific community, and usability for researchers and clinicians. Issues reported by the coordinating center, participating sites, and study subjects were those faced when integrating new technologies into existing clinical trial systems. We then defined elements of a PROMIS Tool Kit required for integrating PROMIS into a multi-center clinical trial environment. The requirements identified in this study serve as a framework for future investigators in the design, development, implementation, and operation of PROMIS Tool Kit technologies.
Diener, Lawrence W.; Nahm, Meredith; Weinfurt, Kevin P.
2013-01-01
New technologies may be required to integrate the National Institutes of Health’s Patient Reported Outcome Management Information System (PROMIS) into multi-center clinical trials. To better understand this need, we identified likely PROMIS reporting formats, developed a multi-center clinical trial process model, and identified gaps between current capabilities and those necessary for PROMIS. These results were evaluated by key trial constituencies. Issues reported by principal investigators fell into two categories: acceptance by key regulators and the scientific community, and usability for researchers and clinicians. Issues reported by the coordinating center, participating sites, and study subjects were those faced when integrating new technologies into existing clinical trial systems. We then defined elements of a PROMIS Tool Kit required for integrating PROMIS into a multi-center clinical trial environment. The requirements identified in this study serve as a framework for future investigators in the design, development, implementation, and operation of PROMIS Tool Kit technologies. PMID:20703765
Translation and integration of numerical atomic orbitals in linear molecules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heinäsmäki, Sami, E-mail: sami.heinasmaki@gmail.com
2014-02-14
We present algorithms for translation and integration of atomic orbitals for LCAO calculations in linear molecules. The method applies to arbitrary radial functions given on a numerical mesh. The algorithms are based on pseudospectral differentiation matrices in two dimensions and the corresponding two-dimensional Gaussian quadratures. As a result, multicenter overlap and Coulomb integrals can be evaluated effectively.
Evaluation of DICOM viewer software for workflow integration in clinical trials
NASA Astrophysics Data System (ADS)
Haak, Daniel; Page, Charles E.; Kabino, Klaus; Deserno, Thomas M.
2015-03-01
The digital imaging and communications in medicine (DICOM) protocol is nowadays the leading standard for capture, exchange and storage of image data in medical applications. A broad range of commercial, free, and open source software tools supporting a variety of DICOM functionality exists. However, different from patient's care in hospital, DICOM has not yet arrived in electronic data capture systems (EDCS) for clinical trials. Due to missing integration, even just the visualization of patient's image data in electronic case report forms (eCRFs) is impossible. Four increasing levels for integration of DICOM components into EDCS are conceivable, raising functionality but also demands on interfaces with each level. Hence, in this paper, a comprehensive evaluation of 27 DICOM viewer software projects is performed, investigating viewing functionality as well as interfaces for integration. Concerning general, integration, and viewing requirements the survey involves the criteria (i) license, (ii) support, (iii) platform, (iv) interfaces, (v) two-dimensional (2D) and (vi) three-dimensional (3D) image viewing functionality. Optimal viewers are suggested for applications in clinical trials for 3D imaging, hospital communication, and workflow. Focusing on open source solutions, the viewers ImageJ and MicroView are superior for 3D visualization, whereas GingkoCADx is advantageous for hospital integration. Concerning workflow optimization in multi-centered clinical trials, we suggest the open source viewer Weasis. Covering most use cases, an EDCS and PACS interconnection with Weasis is suggested.
Electronic structure and chemical bonding of the electron-poor II-V semiconductors ZnSb and ZnAs
NASA Astrophysics Data System (ADS)
Benson, Daryn; Sankey, Otto F.; Häussermann, Ulrich
2011-09-01
The binary compounds ZnSb and ZnAs with the CdSb structure are semiconductors (II-V), although the average electron concentration (3.5 per atom) is lower than that of the tetrahedrally bonded III-V and II-VI archetype systems (four per atom). We report a detailed electronic structure and chemical bonding analysis for ZnSb and ZnAs based on first-principles calculations. ZnSb and ZnAs are compared to the zinc blende-type semiconductors GaSb, ZnTe, GaAs, and ZnSe, as well as the more ionic, hypothetical, II-V systems MgSb and MgAs. We establish a clearly covalent bonding scenario for ZnSb and ZnAs where multicenter bonded structural entities (rhomboid rings Zn2Sb2 and Zn2As2) are connected to each other by classical two-center, two-electron bonds. This bonding scenario is only compatible with a weak ionicity in II-V semiconductor systems, and weak ionicity appears as a necessary condition for the stability of the CdSb structure type. It is argued that a chemical bonding scenario with mixed multicenter and two-center bonding resembles that of boron and boron-rich compounds and is typical of electron-poor sp-bonded semiconductors with average valence electron concentrations below four per atom.
Implementing Single Source: The STARBRITE Proof-of-Concept Study
Kush, Rebecca; Alschuler, Liora; Ruggeri, Roberto; Cassells, Sally; Gupta, Nitin; Bain, Landen; Claise, Karen; Shah, Monica; Nahm, Meredith
2007-01-01
Objective Inefficiencies in clinical trial data collection cause delays, increase costs, and may reduce clinician participation in medical research. In this proof-of-concept study, we examine the feasibility of using point-of-care data capture for both the medical record and clinical research in the setting of a working clinical trial. We hypothesized that by doing so, we could increase reuse of patient data, eliminate redundant data entry, and minimize disruption to clinic workflow. Design We developed and used a point-of-care electronic data capture system to record data during patient visits. The standards-based system was used for clinical research and to generate the clinic note for the medical record. The system worked in parallel with data collection procedures already in place for an ongoing multicenter clinical trial. Our system was iteratively designed after analyzing case report forms and clinic notes, and observing clinic workflow patterns and business procedures. Existing data standards from CDISC and HL7 were used for database insertion and clinical document exchange. Results Our system was successfully integrated into the clinic environment and used in two live test cases without disrupting existing workflow. Analyses performed during system design yielded detailed information on practical issues affecting implementation of systems that automatically extract, store, and reuse healthcare data. Conclusion Although subject to the limitations of a small feasibility study, our study demonstrates that electronic patient data can be reused for prospective multicenter clinical research and patient care, and demonstrates a need for further development of therapeutic area standards that can facilitate researcher use of healthcare data. PMID:17600107
One-range addition theorems for derivatives of Slater-type orbitals.
Guseinov, Israfil
2004-06-01
Using addition theorems for STOs introduced by the author with the help of complete orthonormal sets of psi(alpha)-ETOs (Guseinov II (2003) J Mol Model 9:190-194), where alpha=1, 0, -1, -2, ..., a large number of one-range addition theorems for first and second derivatives of STOs are established. These addition theorems are especially useful for computation of multicenter-multielectron integrals over STOs that arise in the Hartree-Fock-Roothaan approximation and also in the Hylleraas function method, which play a significant role for the study of electronic structure and electron-nuclei interaction properties of atoms, molecules, and solids. The relationships obtained are valid for arbitrary quantum numbers, screening constants and location of STOs.
A Multicenter Study of Volumetric Computed Tomography for Staging Malignant Pleural Mesothelioma
Rusch, Valerie W.; Gill, Ritu; Mitchell, Alan; Naidich, David; Rice, David C.; Pass, Harvey I.; Kindler, Hedy; De Perrot, Marc; Friedberg, Joseph
2016-01-01
Background Standard imaging modalities are inaccurate in staging malignant pleural mesothelioma (MPM). Single institution studies suggest that volumetric computed tomography (VolCT) is more accurate but labor intensive. We established a multicenter network to test interobserver variability, accuracy (relative to pathologic stage) and prognostic significance of semi-automated VolCT. Methods Six institutions electronically submitted clinical and pathologic data to an established multicenter database on patients with MPM who had surgery. Institutional radiologists reviewed preoperative CT scans for quality then submitted via electronic network (AG mednet) to biostatistical center (BC). Two reference radiologists, blinded to clinical data, performed semi-automated tumor volume calculations using commercially available software (Vitrea Enterprise 6.0), then submitted readings to BC. Study endpoints included: feasibility of network; interobserver variability for VolCT; correlation of tumor volume to pTN stages, and overall survival (OS). Results Of 164 cases, 129 were analyzable and read by reference radiologists. Most tumors were <500cm3. A small bias was observed between readers, as one provided consistently larger measurements than the other (mean difference=47.9, p=.0027), but for 80% of cases, the absolute difference was ≤ 200cm3. Spearman correlation between readers was 0.822. Volume correlated with pTN stages and OS, best defined by 3 groups with average volumes of: 91.2, 245.3, 511.3cm3, associated with median OS of 37, 18, 8 months respectively. Conclusions For the first time, a multicenter network was established and initial correlations of tumor volume to pTN stages and OS shown. A larger multicenter international study is planned to confirm results and refine correlations. PMID:27596916
Calculation of NMR chemical shifts. 7. Gauge-invariant INDO method
NASA Astrophysics Data System (ADS)
Fukui, H.; Miura, K.; Hirai, A.
A gauge-invariant INDO method based on the coupled Hartree-Fuck perturbation theory is presented and applied to the calculation of 1H and 13C chemical shifts of hydrocarbons including ring compounds. Invariance of the diamagnetic and paramagnetic shieldings with respect to displacement of the coordinate origin is discussed. Comparison between calculated and experimental results exhibits fairly good agreement, provided that the INDO parameters of Ellis et al. (J. Am. Chem. Soc.94, 4069 (1972)) are used with the inclusion of all multicenter one-electron integrals.
Ellegaard, Trine; Bliksted, Vibeke; Mehlsen, Mimi; Lomborg, Kirsten
2018-05-01
Patient-controlled admissions (PCAs) enable mental health patients by means of a contract to initiate an admission at a mental health hospital unit without using traditional admission procedures. This study was part of a 3-year Danish multicenter project, and we explored how mental health professionals experienced and managed the implementation of a PCA program. The methodology was grounded theory and the sample included 26 participants. We performed a constant comparative analysis to explore the concerns, attitudes, and strategies of mental health professionals. We developed a model of how the mental health professionals strived to integrate PCA into clinical practice. The process was motivated by the idea of establishing a partnership with patients and involved two interrelated strategies to manage (a) the patient-related duties and (b) the admission contracts. The professionals moved from a phase of professional discomfort to a phase of professional awareness, and ended up with professional comprehension.
Li, Ting-Feng; Painter, Richard G.; Ban, Bhupal; ...
2015-06-03
Electron transfer reactions among three prominent colored proteins in intact cells of Acidithiobacillus ferrooxidans were monitored using an integrating cavity absorption meter that permitted the acquisition of accurate absorbance data in suspensions of cells that scattered light. The concentrations of proteins in the periplasmic space were estimated to be 350 and 25 mg/ml for rusticyanin and cytochrome c, respectively; cytochrome a was present as one molecule for every 91 nm2 in the cytoplasmic membrane. All three proteins were rapidly reduced to the same relative extent when suspensions of live bacteria were mixed with different concentrations of ferrous ions at pHmore » 1.5. The subsequent molecular oxygen-dependent oxidation of the multicenter respiratory chain occurred with a single macroscopic rate constant, regardless of the proteins' in vitro redox potentials or their putative positions in the aerobic iron respiratory chain. The crowded electron transport proteins in the periplasm of the organism constituted an electron conductive medium where the network of protein interactions functioned in a concerted fashion as a single ensemble with a standard reduction potential of 650 mV. The appearance of product ferric ions was correlated with the reduction levels of the periplasmic electron transfer proteins; the limiting first-order catalytic rate constant for aerobic respiration on iron was 7,400 s -1. The ability to conduct direct spectrophotometric studies under noninvasive physiological conditions represents a new and powerful approach to examine the extent and rates of biological events in situ without disrupting the complexity of the live cellular environment.« less
Two-electron/24-center (2e/24c) bonding in novel diradical π-dimers.
Gao, Feng-Wei; Zhong, Rong-Lin; Sun, Shi-Ling; Xu, Hong-Liang; Su, Zhong-Min
2016-10-26
A series of diradical π-dimers 2 with interesting pancake-shaped 2e/24c π-π bonding character were designed and investigated based on the famous phenalenyl (PLY) π-dimer with 2e/12c π-π bonding character. The position of stronger interaction between two layers of radicals was found by the Wiberg bond index (WBI) maximum component. Further, the different contributions of the interaction energy were analyzed quantitatively by energy decomposition analysis (EDA). Among these new diradical π-dimers, 2180 has the smallest layer distance and the largest interaction between two layers of radicals. The unusual PLY analogues can provide new insights into the unique features of two-electron/multicenter (2e/mc) π-π bonding.
NASA Astrophysics Data System (ADS)
Gong, Maomao; Li, Xingyu; Zhang, Song Bin; Chen, Xiangjun
2018-05-01
A coplanar asymmetric (e, 2e) measurement on N2O has been reported in 1999 by Cavanagh and Lohmann (1999 J. Phys. B: At. Mol. Opt. Phys. 32 L261), however, the relevant ab initio theoretical study is not available even up to now. In this work, we report theoretical studies of (e, 2e) triple differential cross sections of N2O at the same kinematics using a multicenter distorted-wave method. The influence of the multicenter nature of N2O molecule on the continuum wave function of the ejected electron has been largely considered. The computed results show good agreement with the experimental data for both outer valence 2π and inner valence 4σ orbitals.
Sahoo, Satya S.; Ogbuji, Chimezie; Luo, Lingyun; Dong, Xiao; Cui, Licong; Redline, Susan S.; Zhang, Guo-Qiang
2011-01-01
Clinical studies often use data dictionaries with controlled sets of terms to facilitate data collection, limited interoperability and sharing at a local site. Multi-center retrospective clinical studies require that these data dictionaries, originating from individual participating centers, be harmonized in preparation for the integration of the corresponding clinical research data. Domain ontologies are often used to facilitate multi-center data integration by modeling terms from data dictionaries in a logic-based language, but interoperability among domain ontologies (using automated techniques) is an unresolved issue. Although many upper-level reference ontologies have been proposed to address this challenge, our experience in integrating multi-center sleep medicine data highlights the need for an upper level ontology that models a common set of terms at multiple-levels of abstraction, which is not covered by the existing upper-level ontologies. We introduce a methodology underpinned by a Minimal Domain of Discourse (MiDas) algorithm to automatically extract a minimal common domain of discourse (upper-domain ontology) from an existing domain ontology. Using the Multi-Modality, Multi-Resource Environment for Physiological and Clinical Research (Physio-MIMI) multi-center project in sleep medicine as a use case, we demonstrate the use of MiDas in extracting a minimal domain of discourse for sleep medicine, from Physio-MIMI’s Sleep Domain Ontology (SDO). We then extend the resulting domain of discourse with terms from the data dictionary of the Sleep Heart and Health Study (SHHS) to validate MiDas. To illustrate the wider applicability of MiDas, we automatically extract the respective domains of discourse from 6 sample domain ontologies from the National Center for Biomedical Ontologies (NCBO) and the OBO Foundry. PMID:22195180
Sahoo, Satya S; Ogbuji, Chimezie; Luo, Lingyun; Dong, Xiao; Cui, Licong; Redline, Susan S; Zhang, Guo-Qiang
2011-01-01
Clinical studies often use data dictionaries with controlled sets of terms to facilitate data collection, limited interoperability and sharing at a local site. Multi-center retrospective clinical studies require that these data dictionaries, originating from individual participating centers, be harmonized in preparation for the integration of the corresponding clinical research data. Domain ontologies are often used to facilitate multi-center data integration by modeling terms from data dictionaries in a logic-based language, but interoperability among domain ontologies (using automated techniques) is an unresolved issue. Although many upper-level reference ontologies have been proposed to address this challenge, our experience in integrating multi-center sleep medicine data highlights the need for an upper level ontology that models a common set of terms at multiple-levels of abstraction, which is not covered by the existing upper-level ontologies. We introduce a methodology underpinned by a Minimal Domain of Discourse (MiDas) algorithm to automatically extract a minimal common domain of discourse (upper-domain ontology) from an existing domain ontology. Using the Multi-Modality, Multi-Resource Environment for Physiological and Clinical Research (Physio-MIMI) multi-center project in sleep medicine as a use case, we demonstrate the use of MiDas in extracting a minimal domain of discourse for sleep medicine, from Physio-MIMI's Sleep Domain Ontology (SDO). We then extend the resulting domain of discourse with terms from the data dictionary of the Sleep Heart and Health Study (SHHS) to validate MiDas. To illustrate the wider applicability of MiDas, we automatically extract the respective domains of discourse from 6 sample domain ontologies from the National Center for Biomedical Ontologies (NCBO) and the OBO Foundry.
Tandjung, Kenneth; Basalus, Mounir W Z; Sen, Hanim; Jessurun, Gillian A J; Danse, Peter W; Stoel, Martin; Linssen, Gerard C M; Derks, Anita; van Loenhout, Ton T; Nienhuis, Mark B; Hautvast, Raymond W M; von Birgelen, Clemens
2012-04-01
Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES. Copyright © 2012 Mosby, Inc. All rights reserved.
Development of a Multicenter Density Functional Tight Binding Model for Plutonium Surface Hydriding.
Goldman, Nir; Aradi, Bálint; Lindsey, Rebecca K; Fried, Laurence E
2018-05-08
We detail the creation of a multicenter density functional tight binding (DFTB) model for hydrogen on δ-plutonium, using a framework of new Slater-Koster interaction parameters and a repulsive energy based on the Chebyshev Interaction Model for Efficient Simulation (ChIMES), where two- and three-center atomic interactions are represented by linear combinations of Chebyshev polynomials. We find that our DFTB/ChIMES model yields a total electron density of states for bulk δ-Pu that compares well to that from Density Functional Theory, as well as to a grid of energy calculations representing approximate H 2 dissociation paths on the δ-Pu (100) surface. We then perform molecular dynamics simulations and minimum energy pathway calculations to determine the energetics of surface dissociation and subsurface diffusion on the (100) and (111) surfaces. Our approach allows for the efficient creation of multicenter repulsive energies with a relatively small investment in initial DFT calculations. Our efforts are particularly pertinent to studies that rely on quantum calculations for interpretation and validation, such as experimental determination of chemical reactivity both on surfaces and in condensed phases.
Electron-molecule scattering in a strong laser field: Two-center interference effects
NASA Astrophysics Data System (ADS)
Dakić, J.; Habibović, D.; Čerkić, A.; Busuladžić, M.; Milošević, D. B.
2017-10-01
Laser-assisted scattering of electrons on diatomic molecules is considered using the S -matrix theory within the second Born approximation. The first term of the expansion in powers of the scattering potential corresponds to the direct or single laser-assisted scattering of electrons on molecular targets, while the second term of this expansion corresponds to the laser-assisted rescattering or double scattering. The rescattered electrons may have considerably higher energies in the final state than those that scattered only once. For multicenter polyatomic molecules scattering and rescattering may happen at any center and in any order. All these cases contribute to the scattering amplitude and the interference of different contributions leads to an increase or a decrease of the differential cross section in particular electron energy regions. For diatomic molecules there are two such contributions for single scattering and four contributions for double scattering. Analyzing the spectra of the scattered electrons, we find two interesting effects. For certain molecular orientations, the plateaus in the electron energy spectrum, characteristic of laser-assisted electron-atom scattering, are replaced by a sequence of gradually declining maxima, caused by the two-center interference effects. The second effect is the appearance of symmetric U -shaped structures in the angle-resolved energy spectra, which are described very well by the analytical formulas we provide.
NASA Technical Reports Server (NTRS)
Straton, Jack C.
1989-01-01
The Fourier transform of the multicenter product of N 1s hydrogenic orbitals and M Coulomb or Yukawa potentials is given as an (M+N-1)-dimensional Feynman integral with external momenta and shifted coordinates. This is accomplished through the introduction of an integral transformation, in addition to the standard Feynman transformation for the denominators of the momentum representation of the terms in the product, which moves the resulting denominator into an exponential. This allows the angular dependence of the denominator to be combined with the angular dependence in the plane waves.
Peng, Bo; Kowalski, Karol
2017-01-25
In this paper, we apply reverse Cuthill-McKee (RCM) algorithm to transform two-electron integral tensors to their block diagonal forms. By further applying Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates low-rank factorizations of high-dimensional tensor contractions in post-Hartree-Fock calculations. Finally, we discuss the second-order Møller-Plesset (MP2) method and the linear coupled-cluster model with doubles (L-CCD) as examples to demonstrate the efficiency of this technique in representing the two-electron integrals in a compact form.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Bo; Kowalski, Karol
In this paper, we apply reverse Cuthill-McKee (RCM) algorithm to transform two-electron integral tensors to their block diagonal forms. By further applying Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates low-rank factorizations of high-dimensional tensor contractions in post-Hartree-Fock calculations. Finally, we discuss the second-order Møller-Plesset (MP2) method and the linear coupled-cluster model with doubles (L-CCD) as examples to demonstrate the efficiency of this technique in representing the two-electron integrals in a compact form.
Clinical Decision Support for a Multicenter Trial of Pediatric Head Trauma
Swietlik, Marguerite; Deakyne, Sara; Hoffman, Jeffrey M.; Grundmeier, Robert W.; Paterno, Marilyn D.; Rocha, Beatriz H.; Schaeffer, Molly H; Pabbathi, Deepika; Alessandrini, Evaline; Ballard, Dustin; Goldberg, Howard S.; Kuppermann, Nathan; Dayan, Peter S.
2016-01-01
Summary Introduction For children who present to emergency departments (EDs) due to blunt head trauma, ED clinicians must decide who requires computed tomography (CT) scanning to evaluate for traumatic brain injury (TBI). The Pediatric Emergency Care Applied Research Network (PECARN) derived and validated two age-based prediction rules to identify children at very low risk of clinically-important traumatic brain injuries (ciTBIs) who do not typically require CT scans. In this case report, we describe the strategy used to implement the PECARN TBI prediction rules via electronic health record (EHR) clinical decision support (CDS) as the intervention in a multicenter clinical trial. Methods Thirteen EDs participated in this trial. The 10 sites receiving the CDS intervention used the Epic® EHR. All sites implementing EHR-based CDS built the rules by using the vendor’s CDS engine. Based on a sociotechnical analysis, we designed the CDS so that recommendations could be displayed immediately after any provider entered prediction rule data. One central site developed and tested the intervention package to be exported to other sites. The intervention package included a clinical trial alert, an electronic data collection form, the CDS rules and the format for recommendations. Results The original PECARN head trauma prediction rules were derived from physician documentation while this pragmatic trial led each site to customize their workflows and allow multiple different providers to complete the head trauma assessments. These differences in workflows led to varying completion rates across sites as well as differences in the types of providers completing the electronic data form. Site variation in internal change management processes made it challenging to maintain the same rigor across all sites. This led to downstream effects when data reports were developed. Conclusions The process of a centralized build and export of a CDS system in one commercial EHR system successfully supported a multicenter clinical trial. PMID:27437059
OC ToGo: bed site image integration into OpenClinica with mobile devices
NASA Astrophysics Data System (ADS)
Haak, Daniel; Gehlen, Johan; Jonas, Stephan; Deserno, Thomas M.
2014-03-01
Imaging and image-based measurements nowadays play an essential role in controlled clinical trials, but electronic data capture (EDC) systems insufficiently support integration of captured images by mobile devices (e.g. smartphones and tablets). The web application OpenClinica has established as one of the world's leading EDC systems and is used to collect, manage and store data of clinical trials in electronic case report forms (eCRFs). In this paper, we present a mobile application for instantaneous integration of images into OpenClinica directly during examination on patient's bed site. The communication between the Android application and OpenClinica is based on the simple object access protocol (SOAP) and representational state transfer (REST) web services for metadata, and secure file transfer protocol (SFTP) for image transfer, respectively. OpenClinica's web services are used to query context information (e.g. existing studies, events and subjects) and to import data into the eCRF, as well as export of eCRF metadata and structural information. A stable image transfer is ensured and progress information (e.g. remaining time) visualized to the user. The workflow is demonstrated for a European multi-center registry, where patients with calciphylaxis disease are included. Our approach improves the EDC workflow, saves time, and reduces costs. Furthermore, data privacy is enhanced, since storage of private health data on the imaging devices becomes obsolete.
NASA Astrophysics Data System (ADS)
Kido, Kentaro; Kasahara, Kento; Yokogawa, Daisuke; Sato, Hirofumi
2015-07-01
In this study, we reported the development of a new quantum mechanics/molecular mechanics (QM/MM)-type framework to describe chemical processes in solution by combining standard molecular-orbital calculations with a three-dimensional formalism of integral equation theory for molecular liquids (multi-center molecular Ornstein-Zernike (MC-MOZ) method). The theoretical procedure is very similar to the 3D-reference interaction site model self-consistent field (RISM-SCF) approach. Since the MC-MOZ method is highly parallelized for computation, the present approach has the potential to be one of the most efficient procedures to treat chemical processes in solution. Benchmark tests to check the validity of this approach were performed for two solute (solute water and formaldehyde) systems and a simple SN2 reaction (Cl- + CH3Cl → ClCH3 + Cl-) in aqueous solution. The results for solute molecular properties and solvation structures obtained by the present approach were in reasonable agreement with those obtained by other hybrid frameworks and experiments. In particular, the results of the proposed approach are in excellent agreements with those of 3D-RISM-SCF.
Kido, Kentaro; Kasahara, Kento; Yokogawa, Daisuke; Sato, Hirofumi
2015-07-07
In this study, we reported the development of a new quantum mechanics/molecular mechanics (QM/MM)-type framework to describe chemical processes in solution by combining standard molecular-orbital calculations with a three-dimensional formalism of integral equation theory for molecular liquids (multi-center molecular Ornstein-Zernike (MC-MOZ) method). The theoretical procedure is very similar to the 3D-reference interaction site model self-consistent field (RISM-SCF) approach. Since the MC-MOZ method is highly parallelized for computation, the present approach has the potential to be one of the most efficient procedures to treat chemical processes in solution. Benchmark tests to check the validity of this approach were performed for two solute (solute water and formaldehyde) systems and a simple SN2 reaction (Cl(-) + CH3Cl → ClCH3 + Cl(-)) in aqueous solution. The results for solute molecular properties and solvation structures obtained by the present approach were in reasonable agreement with those obtained by other hybrid frameworks and experiments. In particular, the results of the proposed approach are in excellent agreements with those of 3D-RISM-SCF.
Peng, Bo; Kowalski, Karol
2017-09-12
The representation and storage of two-electron integral tensors are vital in large-scale applications of accurate electronic structure methods. Low-rank representation and efficient storage strategy of integral tensors can significantly reduce the numerical overhead and consequently time-to-solution of these methods. In this work, by combining pivoted incomplete Cholesky decomposition (CD) with a follow-up truncated singular vector decomposition (SVD), we develop a decomposition strategy to approximately represent the two-electron integral tensor in terms of low-rank vectors. A systematic benchmark test on a series of 1-D, 2-D, and 3-D carbon-hydrogen systems demonstrates high efficiency and scalability of the compound two-step decomposition of the two-electron integral tensor in our implementation. For the size of the atomic basis set, N b , ranging from ∼100 up to ∼2,000, the observed numerical scaling of our implementation shows [Formula: see text] versus [Formula: see text] cost of performing single CD on the two-electron integral tensor in most of the other implementations. More importantly, this decomposition strategy can significantly reduce the storage requirement of the atomic orbital (AO) two-electron integral tensor from [Formula: see text] to [Formula: see text] with moderate decomposition thresholds. The accuracy tests have been performed using ground- and excited-state formulations of coupled cluster formalism employing single and double excitations (CCSD) on several benchmark systems including the C 60 molecule described by nearly 1,400 basis functions. The results show that the decomposition thresholds can be generally set to 10 -4 to 10 -3 to give acceptable compromise between efficiency and accuracy.
Guidelines for quality assurance in multicenter trials: a position paper.
Knatterud, G L; Rockhold, F W; George, S L; Barton, F B; Davis, C E; Fairweather, W R; Honohan, T; Mowery, R; O'Neill, R
1998-10-01
In the wake of reports of falsified data in one of the trials of the National Surgical Adjuvant Project for Breast and Bowel Cancer supported by the National Cancer Institute, clinical trials came under close scrutiny by the public, the press, and Congress. Questions were asked about the quality and integrity of the collected data and the analyses and conclusions of trials. In 1995, the leaders of the Society for Clinical Trials (the Chair of the Policy Committee, Dr. David DeMets, and the President of the Society, Dr. Sylvan Green) asked two members of the Society (Dr. Genell Knatterud and Dr. Frank Rockhold) to act as co-chairs of a newly formed subcommittee to discuss the issues of data integrity and auditing. In consultation with Drs. DeMets and Green, the co-chairs selected other members (Ms. Franca Barton, Dr. C.E. Davis, Dr. Bill Fairweather, Dr. Stephen George, Mr. Tom Honohan, Dr. Richard Mowery, and Dr. Robert O'Neill) to serve on the subcommittee. The subcommittee considered "how clean clinical trial data should be, to what extent auditing procedures are required, and who should conduct audits and how often." During the initial discussions, the subcommittee concluded that data auditing was insufficient to achieve data integrity. Accordingly, the subcommittee prepared this set of guidelines for standards of quality assurance for multicenter clinical trials. We include recommendations for appropriate action if problems are detected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Bo; Kowalski, Karol
In this letter, we introduce the reverse Cuthill-McKee (RCM) algorithm, which is often used for the bandwidth reduction of sparse tensors, to transform the two-electron integral tensors to their block diagonal forms. By further applying the pivoted Cholesky decomposition (CD) on each of the diagonal blocks, we are able to represent the high-dimensional two-electron integral tensors in terms of permutation matrices and low-rank Cholesky vectors. This representation facilitates the low-rank factorization of the high-dimensional tensor contractions that are usually encountered in post-Hartree-Fock calculations. In this letter, we discuss the second-order Møller-Plesset (MP2) method and linear coupled- cluster model with doublesmore » (L-CCD) as two simple examples to demonstrate the efficiency of the RCM-CD technique in representing two-electron integrals in a compact form.« less
Big data and visual analytics in anaesthesia and health care.
Simpao, A F; Ahumada, L M; Rehman, M A
2015-09-01
Advances in computer technology, patient monitoring systems, and electronic health record systems have enabled rapid accumulation of patient data in electronic form (i.e. big data). Organizations such as the Anesthesia Quality Institute and Multicenter Perioperative Outcomes Group have spearheaded large-scale efforts to collect anaesthesia big data for outcomes research and quality improvement. Analytics--the systematic use of data combined with quantitative and qualitative analysis to make decisions--can be applied to big data for quality and performance improvements, such as predictive risk assessment, clinical decision support, and resource management. Visual analytics is the science of analytical reasoning facilitated by interactive visual interfaces, and it can facilitate performance of cognitive activities involving big data. Ongoing integration of big data and analytics within anaesthesia and health care will increase demand for anaesthesia professionals who are well versed in both the medical and the information sciences. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhao, Wenle; Pauls, Keith
2015-01-01
Background Centralized outcome adjudication has been used widely in multi-center clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network’s data management center within a homegrown clinical trial management system. In this paper, the system design strategy and database structure are presented. Methods A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. Results By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer one or two days. A total of 7,336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. Conclusions A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. PMID:26464429
Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) Systems Integration Strategy
NASA Technical Reports Server (NTRS)
Gill, Tracy; Merbitz, Jerad; Kennedy, Kriss; Tri, Terry; Toups, Larry; Howe, A. Scott
2011-01-01
The Habitat Demonstration Unit (HDU) project team constructed an analog prototype lunar surface laboratory called the Pressurized Excursion Module (PEM). The prototype unit subsystems were integrated in a short amount of time, utilizing a rapid prototyping approach that brought together over 20 habitation-related technologies from a variety of NASA centers. This paper describes the system integration strategies and lessons learned, that allowed the PEM to be brought from paper design to working field prototype using a multi-center team. The system integration process was based on a rapid prototyping approach. Tailored design review and test and integration processes facilitated that approach. The use of collaboration tools including electronic tools as well as documentation enabled a geographically distributed team take a paper concept to an operational prototype in approximately one year. One of the major tools used in the integration strategy was a coordinated effort to accurately model all the subsystems using computer aided design (CAD), so conflicts were identified before physical components came together. A deliberate effort was made following the deployment of the HDU PEM for field operations to collect lessons learned to facilitate process improvement and inform the design of future flight or analog versions of habitat systems. Significant items within those lessons learned were limitations with the CAD integration approach and the impact of shell design on flexibility of placing systems within the HDU shell.
Electronic noise in CT detectors: Impact on image noise and artifacts.
Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H
2013-10-01
The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.
Zhao, Wenle; Pauls, Keith
2016-04-01
Centralized outcome adjudication has been used widely in multicenter clinical trials in order to prevent potential biases and to reduce variations in important safety and efficacy outcome assessments. Adjudication procedures could vary significantly among different studies. In practice, the coordination of outcome adjudication procedures in many multicenter clinical trials remains as a manual process with low efficiency and high risk of delay. Motivated by the demands from two large clinical trial networks, a generic outcome adjudication module has been developed by the network's data management center within a homegrown clinical trial management system. In this article, the system design strategy and database structure are presented. A generic database model was created to transfer different adjudication procedures into a unified set of sequential adjudication steps. Each adjudication step was defined by one activate condition, one lock condition, one to five categorical data items to capture adjudication results, and one free text field for general comments. Based on this model, a generic outcome adjudication user interface and a generic data processing program were developed within a homegrown clinical trial management system to provide automated coordination of outcome adjudication. By the end of 2014, this generic outcome adjudication module had been implemented in 10 multicenter trials. A total of 29 adjudication procedures were defined with the number of adjudication steps varying from 1 to 7. The implementation of a new adjudication procedure in this generic module took an experienced programmer 1 or 2 days. A total of 7336 outcome events had been adjudicated and 16,235 adjudication step activities had been recorded. In a multicenter trial, 1144 safety outcome event submissions went through a three-step adjudication procedure and reported a median of 3.95 days from safety event case report form submission to adjudication completion. In another trial, 277 clinical outcome events were adjudicated by a six-step procedure and took a median of 23.84 days from outcome event case report form submission to adjudication procedure completion. A generic outcome adjudication module integrated in the clinical trial management system made the automated coordination of efficacy and safety outcome adjudication a reality. © The Author(s) 2015.
El Fadly, AbdenNaji; Rance, Bastien; Lucas, Noël; Mead, Charles; Chatellier, Gilles; Lastic, Pierre-Yves; Jaulent, Marie-Christine; Daniel, Christel
2011-12-01
There are different approaches for repurposing clinical data collected in the Electronic Healthcare Record (EHR) for use in clinical research. Semantic integration of "siloed" applications across domain boundaries is the raison d'être of the standards-based profiles developed by the Integrating the Healthcare Enterprise (IHE) initiative - an initiative by healthcare professionals and industry promoting the coordinated use of established standards such as DICOM and HL7 to address specific clinical needs in support of optimal patient care. In particular, the combination of two IHE profiles - the integration profile "Retrieve Form for Data Capture" (RFD), and the IHE content profile "Clinical Research Document" (CRD) - offers a straightforward approach to repurposing EHR data by enabling the pre-population of the case report forms (eCRF) used for clinical research data capture by Clinical Data Management Systems (CDMS) with previously collected EHR data. Implement an alternative solution of the RFD-CRD integration profile centered around two approaches: (i) Use of the EHR as the single-source data-entry and persistence point in order to ensure that all the clinical data for a given patient could be found in a single source irrespective of the data collection context, i.e. patient care or clinical research; and (ii) Maximize the automatic pre-population process through the use of a semantic interoperability services that identify duplicate or semantically-equivalent eCRF/EHR data elements as they were collected in the EHR context. The RE-USE architecture and associated profiles are focused on defining a set of scalable, standards-based, IHE-compliant profiles that can enable single-source data collection/entry and cross-system data reuse through semantic integration. Specifically, data reuse is realized through the semantic mapping of data collection fields in electronic Case Report Forms (eCRFs) to data elements previously defined as part of patient care-centric templates in the EHR context. The approach was evaluated in the context of a multi-center clinical trial conducted in a large, multi-disciplinary hospital with an installed EHR. Data elements of seven eCRFs used in a multi-center clinical trial were mapped to data elements of patient care-centric templates in use in the EHR at the George Pompidou hospital. 13.4% of the data elements of the eCRFs were found to be represented in EHR templates and were therefore candidate for pre-population. During the execution phase of the clinical study, the semantic mapping architecture enabled data persisted in the EHR context as part of clinical care to be used to pre-populate eCRFS for use without secondary data entry. To ensure that the pre-populated data is viable for use in the clinical research context, all pre-populated eCRF data needs to be first approved by a trial investigator prior to being persisted in a research data store within a CDMS. Single-source data entry in the clinical care context for use in the clinical research context - a process enabled through the use of the EHR as single point of data entry, can - if demonstrated to be a viable strategy - not only significantly reduce data collection efforts while simultaneously increasing data collection accuracy secondary to elimination of transcription or double-entry errors between the two contexts but also ensure that all the clinical data for a given patient, irrespective of the data collection context, are available in the EHR for decision support and treatment planning. The RE-USE approach used mapping algorithms to identify semantic coherence between clinical care and clinical research data elements and pre-populate eCRFs. The RE-USE project utilized SNOMED International v.3.5 as its "pivot reference terminology" to support EHR-to-eCRF mapping, a decision that likely enhanced the "recall" of the mapping algorithms. The RE-USE results demonstrate the difficult challenges involved in semantic integration between the clinical care and clinical research contexts. Copyright © 2011 Elsevier Inc. All rights reserved.
Validation of the Community Integration Questionnaire in the adult burn injury population.
Gerrard, Paul; Kazis, Lewis E; Ryan, Colleen M; Shie, Vivian L; Holavanahalli, Radha; Lee, Austin; Jette, Alan; Fauerbach, James A; Esselman, Peter; Herndon, David; Schneider, Jeffrey C
2015-11-01
With improved survival, long-term effects of burn injuries on quality of life, particularly community integration, are important outcomes. This study aims to assess the Community Integration Questionnaire's psychometric properties in the adult burn population. Data were obtained from a multicenter longitudinal data set of burn survivors. The psychometric properties of the Community Integration Questionnaire (n = 492) were examined. The questionnaire items were evaluated for clinical and substantive relevance; validation procedures were conducted on different samples of the population; construct validity was assessed using exploratory factor analysis; internal consistency reliability was examined using Cronbach's α statistics; and item response theory was applied to the final models. The CIQ-15 was reduced by two questions to form the CIQ-13, with a two-factor structure, interpreted as self/family care and social integration. Item response theory testing suggests that Factor 2 captures a wider range of community integration levels. Cronbach's α was 0.80 for Factor 1, 0.77 for Factor 2, and 0.79 for the test as a whole. The CIQ-13 demonstrates validity and reliability in the adult burn survivor population addressing issues of self/family care and social integration. This instrument is useful in future research of community reintegration outcomes in the burn population.
Buckow, Karoline; Quade, Matthias; Rienhoff, Otto; Nussbeck, Sara Y
2016-01-01
The observation of growing "difficulties" in IT-infrastructures in neuroscience research during the last years led to a search for reasons and an analysis on how this phenomenon is reflected in the scientific literature. With a retrospective analysis of nine examples of multicenter research projects in the neurosciences and a literature review the observation was systematically analyzed. Results show that the rise in complexity mainly stems from two reasons: (1) more and more need for information on quality and context of research data (metadata) and (2) long-term requirements to handle the consent and identity/pseudonyms of study participants and biomaterials in relation to legal requirements. The combination of these two aspects together with very long study times and data evaluation periods are components of the subjectively perceived "difficulties". A direct consequence of this result is that big multicenter trials are becoming part of integrated research data environments and are not standing alone for themselves anymore. This drives up the resource needs regarding the IT-infrastructure in neuroscience research. In contrast to these findings, literature on this development is scarce and the problem probably underestimated. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Bo; Kowalski, Karol
The representation and storage of two-electron integral tensors are vital in large- scale applications of accurate electronic structure methods. Low-rank representation and efficient storage strategy of integral tensors can significantly reduce the numerical overhead and consequently time-to-solution of these methods. In this paper, by combining pivoted incomplete Cholesky decomposition (CD) with a follow-up truncated singular vector decomposition (SVD), we develop a decomposition strategy to approximately represent the two-electron integral tensor in terms of low-rank vectors. A systematic benchmark test on a series of 1-D, 2-D, and 3-D carbon-hydrogen systems demonstrates high efficiency and scalability of the compound two-step decomposition ofmore » the two-electron integral tensor in our implementation. For the size of atomic basis set N_b ranging from ~ 100 up to ~ 2, 000, the observed numerical scaling of our implementation shows O(N_b^{2.5~3}) versus O(N_b^{3~4}) of single CD in most of other implementations. More importantly, this decomposition strategy can significantly reduce the storage requirement of the atomic-orbital (AO) two-electron integral tensor from O(N_b^4) to O(N_b^2 log_{10}(N_b)) with moderate decomposition thresholds. The accuracy tests have been performed using ground- and excited-state formulations of coupled- cluster formalism employing single and double excitations (CCSD) on several bench- mark systems including the C_{60} molecule described by nearly 1,400 basis functions. The results show that the decomposition thresholds can be generally set to 10^{-4} to 10^{-3} to give acceptable compromise between efficiency and accuracy.« less
The Habitat Demonstration Unit Project Overview
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Grill, Tracy R.; Tri, Terry O.; Howe, Alan S.
2010-01-01
This paper will describe an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) Project. The HDU project is a "technology-pull" project that integrates technologies and innovations from numerous NASA centers. This project will be used to investigate and validate surface architectures, operations concepts, and requirements definition of various habitation concepts. The first habitation configuration this project will build and test is the Pressurized Excursion Module (PEM). This habitat configuration - the PEM - is based on the Constellation Architecture Scenario 12.1 concept of a vertically oriented habitat module. The HDU project will be tested as part of the 2010 Desert Research and Technologies Simulations (D-RATS) test objectives. The purpose of this project is to develop, integrate, test, and evaluate a habitat configuration in the context of the mission architectures and surface operation concepts. A multi-center approach will be leveraged to build, integrate, and test the PEM through a shared collaborative effort of multiple NASA centers. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Lunar Surface Systems Project Office (LSSPO) to test surface elements in a surface analog environment. The 2010 analog field test will include two Lunar Electric Rovers (LER) and the PEM among other surface demonstration elements. This paper will describe the overall objectives, its various habitat configurations, strategic plan, and technology integration as it pertains to the 2010 and 2011 field analog tests. To accomplish the development of the PEM from conception in June 2009 to rollout for operations in July 2010, the HDU project team is using a set of design standards to define the interfaces between the various systems of PEM and to the payloads, such as the Geology Lab, that those systems will support. Scheduled activities such as early fit-checks and the utilization of a habitat avionics test bed prior to equipment installation into PEM are planned to facilitate the integration process.
Self-consistent pseudopotential calculation of the bulk properties of Mo and W
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zunger, A.; Cohen, M.L.
The bulk properties of Mo and W are calculated using the recently developed momentum-space approach for calculating total energy via a nonlocal pseudopotential. This approach avoids any shape approximation to the variational charge density (e.g., muffin tins), is fully self-consistent, and replaces the multidimensional and multicenter integrals akin to real-space representations by simple and readily convergent reciprocal-space lattice sums. We use first-principles atomic pseudopotentials which have been previously demonstrated to yield band structures and charge densities for both semiconductors and transition metals in good agreement with experiment and all-electron calculations. Using a mixed-basis representation for the crystalline wave function, wemore » are able to accurately reproduce both the localized and itinerant features of the electronic states in these systems. These first-principles pseudopotentials, together with the self-consistent density-functional representation for both the exchange and the correlation screening, yields agreement with experiment of 0.2% in the lattice parameters, 2% and 11% for the binding energies of Mo and W, respectively, and 12% and 7% for the bulk moduli of Mo and W, respectively.« less
Electronic data capture and DICOM data management in multi-center clinical trials
NASA Astrophysics Data System (ADS)
Haak, Daniel; Page, Charles-E.; Deserno, Thomas M.
2016-03-01
Providing eligibility, efficacy and security evaluation by quantitative and qualitative disease findings, medical imaging has become increasingly important in clinical trials. Here, subject's data is today captured in electronic case reports forms (eCRFs), which are offered by electronic data capture (EDC) systems. However, integration of subject's medical image data into eCRFs is insufficiently supported. Neither integration of subject's digital imaging and communications in medicine (DICOM) data, nor communication with picture archiving and communication systems (PACS), is possible. This aggravates the workflow of the study personnel, in special regarding studies with distributed data capture in multiple sites. Hence, in this work, a system architecture is presented, which connects an EDC system, a PACS and a DICOM viewer via the web access to DICOM objects (WADO) protocol. The architecture is implemented using the open source tools OpenClinica, DCM4CHEE and Weasis. The eCRF forms the primary endpoint for the study personnel, where subject's image data is stored and retrieved. Background communication with the PACS is completely hidden for the users. Data privacy and consistency is ensured by automatic de-identification and re-labelling of DICOM data with context information (e.g. study and subject identifiers), respectively. The system is exemplarily demonstrated in a clinical trial, where computer tomography (CT) data is de-centrally captured from the subjects and centrally read by a chief radiologists to decide on inclusion of the subjects in the trial. Errors, latency and costs in the EDC workflow are reduced, while, a research database is implicitly built up in the background.
Hybrid fluorescence and electron cryo-microscopy for simultaneous electron and photon imaging.
Iijima, Hirofumi; Fukuda, Yoshiyuki; Arai, Yoshihiro; Terakawa, Susumu; Yamamoto, Naoki; Nagayama, Kuniaki
2014-01-01
Integration of fluorescence light and transmission electron microscopy into the same device would represent an important advance in correlative microscopy, which traditionally involves two separate microscopes for imaging. To achieve such integration, the primary technical challenge that must be solved regards how to arrange two objective lenses used for light and electron microscopy in such a manner that they can properly focus on a single specimen. To address this issue, both lateral displacement of the specimen between two lenses and specimen rotation have been proposed. Such movement of the specimen allows sequential collection of two kinds of microscopic images of a single target, but prevents simultaneous imaging. This shortcoming has been made up by using a simple optical device, a reflection mirror. Here, we present an approach toward the versatile integration of fluorescence and electron microscopy for simultaneous imaging. The potential of simultaneous hybrid microscopy was demonstrated by fluorescence and electron sequential imaging of a fluorescent protein expressed in cells and cathodoluminescence imaging of fluorescent beads. Copyright © 2013 Elsevier Inc. All rights reserved.
Walden, Anita; Nahm, Meredith; Barnett, M Edwina; Conde, Jose G; Dent, Andrew; Fadiel, Ahmed; Perry, Theresa; Tolk, Chris; Tcheng, James E; Eisenstein, Eric L
2011-01-01
New data management models are emerging in multi-center clinical studies. We evaluated the incremental costs associated with decentralized vs. centralized models. We developed clinical research network economic models to evaluate three data management models: centralized, decentralized with local software, and decentralized with shared database. Descriptive information from three clinical research studies served as inputs for these models. The primary outcome was total data management costs. Secondary outcomes included: data management costs for sites, local data centers, and central coordinating centers. Both decentralized models were more costly than the centralized model for each clinical research study: the decentralized with local software model was the most expensive. Decreasing the number of local data centers and case book pages reduced cost differentials between models. Decentralized vs. centralized data management in multi-center clinical research studies is associated with increases in data management costs.
Walden, Anita; Nahm, Meredith; Barnett, M. Edwina; Conde, Jose G.; Dent, Andrew; Fadiel, Ahmed; Perry, Theresa; Tolk, Chris; Tcheng, James E.; Eisenstein, Eric L.
2012-01-01
Background New data management models are emerging in multi-center clinical studies. We evaluated the incremental costs associated with decentralized vs. centralized models. Methods We developed clinical research network economic models to evaluate three data management models: centralized, decentralized with local software, and decentralized with shared database. Descriptive information from three clinical research studies served as inputs for these models. Main Outcome Measures The primary outcome was total data management costs. Secondary outcomes included: data management costs for sites, local data centers, and central coordinating centers. Results Both decentralized models were more costly than the centralized model for each clinical research study: the decentralized with local software model was the most expensive. Decreasing the number of local data centers and case book pages reduced cost differentials between models. Conclusion Decentralized vs. centralized data management in multi-center clinical research studies is associated with increases in data management costs. PMID:21335692
The COMET Sleep Research Platform.
Nichols, Deborah A; DeSalvo, Steven; Miller, Richard A; Jónsson, Darrell; Griffin, Kara S; Hyde, Pamela R; Walsh, James K; Kushida, Clete A
2014-01-01
The Comparative Outcomes Management with Electronic Data Technology (COMET) platform is extensible and designed for facilitating multicenter electronic clinical research. Our research goals were the following: (1) to conduct a comparative effectiveness trial (CET) for two obstructive sleep apnea treatments-positive airway pressure versus oral appliance therapy; and (2) to establish a new electronic network infrastructure that would support this study and other clinical research studies. The COMET platform was created to satisfy the needs of CET with a focus on creating a platform that provides comprehensive toolsets, multisite collaboration, and end-to-end data management. The platform also provides medical researchers the ability to visualize and interpret data using business intelligence (BI) tools. COMET is a research platform that is scalable and extensible, and which, in a future version, can accommodate big data sets and enable efficient and effective research across multiple studies and medical specialties. The COMET platform components were designed for an eventual move to a cloud computing infrastructure that enhances sustainability, overall cost effectiveness, and return on investment.
The COMET Sleep Research Platform
Nichols, Deborah A.; DeSalvo, Steven; Miller, Richard A.; Jónsson, Darrell; Griffin, Kara S.; Hyde, Pamela R.; Walsh, James K.; Kushida, Clete A.
2014-01-01
Introduction: The Comparative Outcomes Management with Electronic Data Technology (COMET) platform is extensible and designed for facilitating multicenter electronic clinical research. Background: Our research goals were the following: (1) to conduct a comparative effectiveness trial (CET) for two obstructive sleep apnea treatments—positive airway pressure versus oral appliance therapy; and (2) to establish a new electronic network infrastructure that would support this study and other clinical research studies. Discussion: The COMET platform was created to satisfy the needs of CET with a focus on creating a platform that provides comprehensive toolsets, multisite collaboration, and end-to-end data management. The platform also provides medical researchers the ability to visualize and interpret data using business intelligence (BI) tools. Conclusion: COMET is a research platform that is scalable and extensible, and which, in a future version, can accommodate big data sets and enable efficient and effective research across multiple studies and medical specialties. The COMET platform components were designed for an eventual move to a cloud computing infrastructure that enhances sustainability, overall cost effectiveness, and return on investment. PMID:25848590
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boellaard, Ronald, E-mail: r.boellaard@vumc.nl; European Association of Nuclear Medicine Research Ltd., Vienna 1060; European Association of Nuclear Medicine Physics Committee, Vienna 1060
2015-10-15
Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5more » min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.« less
ERIC Educational Resources Information Center
Nwagwu, Lazarus; Azih, Nonye
2015-01-01
The study was conducted to assess readiness for integration of electronic learning into business education programmes in tertiary institutions in Ebonyi State. Two research questions and two hypotheses guided the study. The population was 37 business education lecturers and 748 Business Education Students in tertiary institutions that offer…
Energy Systems Integration News | Energy Systems Integration Facility |
by Google and the IEEE Power Electronics Society brought their inverters to NREL's Energy Systems , and others in the power electronics industry. NREL researchers have collaborated with Google and IEEE Power Electronics On October 8, the U.S. Department of Energy (DOE) announced the two universities
Photoionization of furan from the ground and excited electronic states.
Ponzi, Aurora; Sapunar, Marin; Angeli, Celestino; Cimiraglia, Renzo; Došlić, Nađa; Decleva, Piero
2016-02-28
Here we present a comparative computational study of the photoionization of furan from the ground and the two lowest-lying excited electronic states. The study aims to assess the quality of the computational methods currently employed for treating bound and continuum states in photoionization. For the ionization from the ground electronic state, we show that the Dyson orbital approach combined with an accurate solution of the continuum one particle wave functions in a multicenter B-spline basis, at the density functional theory (DFT) level, provides cross sections and asymmetry parameters in excellent agreement with experimental data. On the contrary, when the Dyson orbitals approach is combined with the Coulomb and orthogonalized Coulomb treatments of the continuum, the results are qualitatively different. In excited electronic states, three electronic structure methods, TDDFT, ADC(2), and CASSCF, have been used for the computation of the Dyson orbitals, while the continuum was treated at the B-spline/DFT level. We show that photoionization observables are sensitive probes of the nature of the excited states as well as of the quality of excited state wave functions. This paves the way for applications in more complex situations such as time resolved photoionization spectroscopy.
King, Andrew W; Baskerville, Adam L; Cox, Hazel
2018-03-13
An implementation of the Hartree-Fock (HF) method using a Laguerre-based wave function is described and used to accurately study the ground state of two-electron atoms in the fixed nucleus approximation, and by comparison with fully correlated (FC) energies, used to determine accurate electron correlation energies. A variational parameter A is included in the wave function and is shown to rapidly increase the convergence of the energy. The one-electron integrals are solved by series solution and an analytical form is found for the two-electron integrals. This methodology is used to produce accurate wave functions, energies and expectation values for the helium isoelectronic sequence, including at low nuclear charge just prior to electron detachment. Additionally, the critical nuclear charge for binding two electrons within the HF approach is calculated and determined to be Z HF C =1.031 177 528.This article is part of the theme issue 'Modern theoretical chemistry'. © 2018 The Author(s).
Attractive electron-electron interactions within robust local fitting approximations.
Merlot, Patrick; Kjærgaard, Thomas; Helgaker, Trygve; Lindh, Roland; Aquilante, Francesco; Reine, Simen; Pedersen, Thomas Bondo
2013-06-30
An analysis of Dunlap's robust fitting approach reveals that the resulting two-electron integral matrix is not manifestly positive semidefinite when local fitting domains or non-Coulomb fitting metrics are used. We present a highly local approximate method for evaluating four-center two-electron integrals based on the resolution-of-the-identity (RI) approximation and apply it to the construction of the Coulomb and exchange contributions to the Fock matrix. In this pair-atomic resolution-of-the-identity (PARI) approach, atomic-orbital (AO) products are expanded in auxiliary functions centered on the two atoms associated with each product. Numerical tests indicate that in 1% or less of all Hartree-Fock and Kohn-Sham calculations, the indefinite integral matrix causes nonconvergence in the self-consistent-field iterations. In these cases, the two-electron contribution to the total energy becomes negative, meaning that the electronic interaction is effectively attractive, and the total energy is dramatically lower than that obtained with exact integrals. In the vast majority of our test cases, however, the indefiniteness does not interfere with convergence. The total energy accuracy is comparable to that of the standard Coulomb-metric RI method. The speed-up compared with conventional algorithms is similar to the RI method for Coulomb contributions; exchange contributions are accelerated by a factor of up to eight with a triple-zeta quality basis set. A positive semidefinite integral matrix is recovered within PARI by introducing local auxiliary basis functions spanning the full AO product space, as may be achieved by using Cholesky-decomposition techniques. Local completion, however, slows down the algorithm to a level comparable with or below conventional calculations. Copyright © 2013 Wiley Periodicals, Inc.
Whelen, A Christian; Bankowski, Matthew J; Furuya, Glenn; Honda, Stacey; Ueki, Robert; Chan, Amelia; Higa, Karen; Kumashiro, Diane; Moore, Nathaniel; Lee, Roland; Koyamatsu, Terrie; Effler, Paul V
2010-01-01
We integrated multicenter, real-time (RTi) reverse transcription polymerase chain reaction (RT-PCR) screening into a statewide laboratory algorithm for influenza surveillance and response. Each of three sites developed its own testing strategy and was challenged with one randomized and blinded panel of 50 specimens previously tested for respiratory viruses. Following testing, each participating laboratory reported its results to the Hawaii State Department of Health, State Laboratories Division for evaluation and possible discrepant analysis. Two of three laboratories reported a 100% sensitivity and specificity, resulting in a 100% positive predictive value and a 100% negative predictive value (NPV) for influenza type A. The third laboratory showed a 71% sensitivity for influenza type A (83% NPV) with 100% specificity. All three laboratories were 100% sensitive and specific for the detection of influenza type B. Discrepant analysis indicated that the lack of sensitivity experienced by the third laboratory may have been due to the analyte-specific reagent probe used by that laboratory. Use of a newer version of the product with a secondary panel of 20 specimens resulted in a sensitivity and specificity of 100%. All three laboratories successfully verified their ability to conduct clinical testing for influenza using diverse nucleic acid extraction and RTi RT-PCR platforms. Successful completion of the verification by all collaborating laboratories paved the way for the integration of those facilities into a statewide laboratory algorithm for influenza surveillance and response.
Patterning two-dimensional chalcogenide crystals of Bi2Se3 and In2Se3 and efficient photodetectors
Zheng, Wenshan; Xie, Tian; Zhou, Yu; Chen, Y.L.; Jiang, Wei; Zhao, Shuli; Wu, Jinxiong; Jing, Yumei; Wu, Yue; Chen, Guanchu; Guo, Yunfan; Yin, Jianbo; Huang, Shaoyun; Xu, H.Q.; Liu, Zhongfan; Peng, Hailin
2015-01-01
Patterning of high-quality two-dimensional chalcogenide crystals with unique planar structures and various fascinating electronic properties offers great potential for batch fabrication and integration of electronic and optoelectronic devices. However, it remains a challenge that requires accurate control of the crystallization, thickness, position, orientation and layout. Here we develop a method that combines microintaglio printing with van der Waals epitaxy to efficiently pattern various single-crystal two-dimensional chalcogenides onto transparent insulating mica substrates. Using this approach, we have patterned large-area arrays of two-dimensional single-crystal Bi2Se3 topological insulator with a record high Hall mobility of ∼1,750 cm2 V−1 s−1 at room temperature. Furthermore, our patterned two-dimensional In2Se3 crystal arrays have been integrated and packaged to flexible photodetectors, yielding an ultrahigh external photoresponsivity of ∼1,650 A W−1 at 633 nm. The facile patterning, integration and packaging of high-quality two-dimensional chalcogenide crystals hold promise for innovations of next-generation photodetector arrays, wearable electronics and integrated optoelectronic circuits. PMID:25898022
Applying World Wide Web technology to the study of patients with rare diseases.
de Groen, P C; Barry, J A; Schaller, W J
1998-07-15
Randomized, controlled trials of sporadic diseases are rarely conducted. Recent developments in communication technology, particularly the World Wide Web, allow efficient dissemination and exchange of information. However, software for the identification of patients with a rare disease and subsequent data entry and analysis in a secure Web database are currently not available. To study cholangiocarcinoma, a rare cancer of the bile ducts, we developed a computerized disease tracing system coupled with a database accessible on the Web. The tracing system scans computerized information systems on a daily basis and forwards demographic information on patients with bile duct abnormalities to an electronic mailbox. If informed consent is given, the patient's demographic and preexisting medical information available in medical database servers are electronically forwarded to a UNIX research database. Information from further patient-physician interactions and procedures is also entered into this database. The database is equipped with a Web user interface that allows data entry from various platforms (PC-compatible, Macintosh, and UNIX workstations) anywhere inside or outside our institution. To ensure patient confidentiality and data security, the database includes all security measures required for electronic medical records. The combination of a Web-based disease tracing system and a database has broad applications, particularly for the integration of clinical research within clinical practice and for the coordination of multicenter trials.
Impact of the Cancer Prevention and Control Research Network
Ribisl, Kurt M.; Fernandez, Maria E.; Friedman, Daniela B.; Hannon, Peggy; Leeman, Jennifer; Moore, Alexis; Olson, Lindsay; Ory, Marcia; Risendal, Betsy; Sheble, Laura; Taylor, Vicky; Williams, Rebecca; Weiner, Bryan J.
2018-01-01
The Cancer Prevention and Control Research Network (CPCRN) is a thematic network dedicated to accelerating the adoption of evidence-based cancer prevention and control practices in communities by advancing dissemination and implementation science. Funded by the Centers for Disease Control and Prevention and National Cancer Institute, CPCRN has operated at two levels: Each participating Network Center conducts research projects with primarily local partners as well as multicenter collaborative research projects with state and national partners. Through multicenter collaboration, thematic networks leverage the expertise, resources, and partnerships of participating centers to conduct research projects collectively that might not be feasible individually. Although multicenter collaboration often is advocated, it is challenging to promote and assess. Using bibliometric network analysis and other graphical methods, this paper describes CPCRN’s multicenter publication progression from 2004 to 2014. Searching PubMed, Scopus, and Web of Science in 2014 identified 249 peer-reviewed CPCRN publications involving two or more centers out of 6,534 total. The research and public health impact of these multicenter collaborative projects initiated by CPCRN during that 10-year period were then examined. CPCRN established numerous workgroups around topics such as: 2-1-1, training and technical assistance, colorectal cancer control, federally qualified health centers, cancer survivorship, and human papillomavirus. The paper discusses the challenges that arise in promoting multicenter collaboration and the strategies that CPCRN uses to address those challenges. The lessons learned should broadly interest those seeking to promote multisite collaboration to address public health problems, such as cancer prevention and control. PMID:28215371
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pederson, Mark R., E-mail: mark.pederson@science.doe.gov
2015-04-14
It is tacitly accepted that, for practical basis sets consisting of N functions, solution of the two-electron Coulomb problem in quantum mechanics requires storage of O(N{sup 4}) integrals in the small N limit. For localized functions, in the large N limit, or for planewaves, due to closure, the storage can be reduced to O(N{sup 2}) integrals. Here, it is shown that the storage can be further reduced to O(N{sup 2/3}) for separable basis functions. A practical algorithm, that uses standard one-dimensional Gaussian-quadrature sums, is demonstrated. The resulting algorithm allows for the simultaneous storage, or fast reconstruction, of any two-electron Coulombmore » integral required for a many-electron calculation on processors with limited memory and disk space. For example, for calculations involving a basis of 9171 planewaves, the memory required to effectively store all Coulomb integrals decreases from 2.8 Gbytes to less than 2.4 Mbytes.« less
Pederson, Mark R
2015-04-14
It is tacitly accepted that, for practical basis sets consisting of N functions, solution of the two-electron Coulomb problem in quantum mechanics requires storage of O(N(4)) integrals in the small N limit. For localized functions, in the large N limit, or for planewaves, due to closure, the storage can be reduced to O(N(2)) integrals. Here, it is shown that the storage can be further reduced to O(N(2/3)) for separable basis functions. A practical algorithm, that uses standard one-dimensional Gaussian-quadrature sums, is demonstrated. The resulting algorithm allows for the simultaneous storage, or fast reconstruction, of any two-electron Coulomb integral required for a many-electron calculation on processors with limited memory and disk space. For example, for calculations involving a basis of 9171 planewaves, the memory required to effectively store all Coulomb integrals decreases from 2.8 Gbytes to less than 2.4 Mbytes.
NASA Technical Reports Server (NTRS)
Straton, Jack C.
1989-01-01
The class of integrals containing the product of N 1s hydrogenic orbitals and M Coulomb or Yukawa potentials with m plane waves is investigated analytically. The results obtained by Straton (1989) are extended and generalized. It is shown that the dimensionality of the entire class can be reduced from 3m to M+N-1.
Lam, Ming Kai; Sen, Hanim; Tandjung, Kenneth; van Houwelingen, K Gert; de Vries, Arie G; Danse, Peter W; Schotborgh, Carl E; Scholte, Martijn; Löwik, Marije M; Linssen, Gerard C M; Ijzerman, Maarten J; van der Palen, Job; Doggen, Carine J M; von Birgelen, Clemens
2014-04-01
To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. BIO-RESORT is an investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non-inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.
Freedman, Roger A; Petrakian, Alex; Boyce, Ker; Haffajee, Charles; Val-Mejias, Jesus E; Oza, Ashish L
2009-02-01
Right ventricular (RV) anodal stimulation may occur in cardiac resynchronization therapy defibrillators (CRT-D) when left ventricular (LV) pacing is configured between the LV lead and an electrode on the RV defibrillator lead. RV defibrillator leads can have a dedicated proximal pacing ring electrode (dedicated bipolar) or utilize the distal shocking coil as the proximal pacing electrode (integrated bipolar). This study compares the performance of integrated versus dedicated leads with respect to anodal stimulation incidence, sensing, and inappropriate ventricular tachyarrhythmia detection in patients implanted with CRT-D. Two hundred ninety-two patients were randomly assigned to receive dedicated or integrated bipolar RV leads at the time of CRT-D implantation. Patients were followed for 6 months. Patients with dedicated bipolar RV leads exhibited markedly higher rates of anodal stimulation than did patients with integrated leads. The incidence of anodal stimulation was 64% at implant for dedicated bipolar RV leads compared to 1% for integrated bipolar RV leads. The likelihood of anodal stimulation in patients with dedicated leads fell progressively during the 6-month follow-up (51.5%), but always exceeded the incidence of anodal stimulation in patients with integrated leads (5%). Clinically detectable undersensing and oversensing were very unusual and did not differ significantly between lead designs. There were no inappropriate ventricular tachyarrhythmia detections for either lead type. Integrated bipolar RV defibrillator leads had a significantly lower incidence of RV anodal stimulation when compared to dedicated bipolar RV defibrillation leads, with no clinically detectable oversensing or undersensing, and with no inappropriate ventricular tachyarrhythmia detections for either lead type.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narumanchi, S.; Bennion, K.; DeVoto, D.
This report describes the research into advanced liquid cooling, integrated power module cooling, high temperature air cooled power electronics, two-phase cooling for power electronics, and electric motor thermal management by NREL's Power Electronics group in FY13.
Patterned arrays of lateral heterojunctions within monolayer two-dimensional semiconductors
Mahjouri-Samani, Masoud; Lin, Ming-Wei; Wang, Kai; Lupini, Andrew R.; Lee, Jaekwang; Basile, Leonardo; Boulesbaa, Abdelaziz; Rouleau, Christopher M.; Puretzky, Alexander A.; Ivanov, Ilia N.; Xiao, Kai; Yoon, Mina; Geohegan, David B.
2015-01-01
The formation of semiconductor heterojunctions and their high-density integration are foundations of modern electronics and optoelectronics. To enable two-dimensional crystalline semiconductors as building blocks in next-generation electronics, developing methods to deterministically form lateral heterojunctions is crucial. Here we demonstrate an approach for the formation of lithographically patterned arrays of lateral semiconducting heterojunctions within a single two-dimensional crystal. Electron beam lithography is used to pattern MoSe2 monolayer crystals with SiO2, and the exposed locations are selectively and totally converted to MoS2 using pulsed laser vaporization of sulfur to form MoSe2/MoS2 heterojunctions in predefined patterns. The junctions and conversion process are studied by Raman and photoluminescence spectroscopy, atomically resolved scanning transmission electron microscopy and device characterization. This demonstration of lateral heterojunction arrays within a monolayer crystal is an essential step for the integration of two-dimensional semiconductor building blocks with different electronic and optoelectronic properties for high-density, ultrathin devices. PMID:26198727
Rationale, design and methods of the HEALTHY study behavior intervention component
USDA-ARS?s Scientific Manuscript database
HEALTHY was a multi-center primary prevention trial designed to reduce risk factors for type 2 diabetes in adolescents. Seven centers each recruited six middle schools that were randomized to either intervention or control. The HEALTHY intervention integrated multiple components in nutrition, physic...
Synthesis of monolithic graphene – graphite integrated electronics
Park, Jang-Ung; Nam, SungWoo; Lee, Mi-Sun; Lieber, Charles M.
2013-01-01
Encoding electronic functionality into nanoscale elements during chemical synthesis has been extensively explored over the past decade as the key to developing integrated nanosystems1 with functions defined by synthesis2-6. Graphene7-12 has been recently explored as a two-dimensional nanoscale material, and has demonstrated simple device functions based on conventional top-down fabrication13-20. However, the synthetic approach to encoding electronic functionality and thus enabling an entire integrated graphene electronics in a chemical synthesis had not previously been demonstrated. Here we report an unconventional approach for the synthesis of monolithically-integrated electronic devices based on graphene and graphite. Spatial patterning of heterogeneous catalyst metals permits the selective growth of graphene and graphite, with controlled number of graphene layers. Graphene transistor arrays with graphitic electrodes and interconnects were formed from synthesis. These functional, all-carbon structures were transferrable onto a variety of substrates. The integrated transistor arrays were used to demonstrate real-time, multiplexed chemical sensing, and more significantly, multiple carbon layers of the graphene-graphite device components were vertically assembled to form a three-dimensional flexible structure which served as a top-gate transistor array. These results represent a substantial progress towards encoding electronic functionality via chemical synthesis and suggest future promise for one-step integration of graphene-graphite based electronics. PMID:22101813
Synthesis of monolithic graphene-graphite integrated electronics.
Park, Jang-Ung; Nam, SungWoo; Lee, Mi-Sun; Lieber, Charles M
2011-11-20
Encoding electronic functionality into nanoscale elements during chemical synthesis has been extensively explored over the past decade as the key to developing integrated nanosystems with functions defined by synthesis. Graphene has been recently explored as a two-dimensional nanoscale material, and has demonstrated simple device functions based on conventional top-down fabrication. However, the synthetic approach to encoding electronic functionality and thus enabling an entire integrated graphene electronics in a chemical synthesis had not previously been demonstrated. Here we report an unconventional approach for the synthesis of monolithically integrated electronic devices based on graphene and graphite. Spatial patterning of heterogeneous metal catalysts permits the selective growth of graphene and graphite, with a controlled number of graphene layers. Graphene transistor arrays with graphitic electrodes and interconnects were formed from the synthesis. These functional, all-carbon structures were transferable onto a variety of substrates. The integrated transistor arrays were used to demonstrate real-time, multiplexed chemical sensing and more significantly, multiple carbon layers of the graphene-graphite device components were vertically assembled to form a three-dimensional flexible structure which served as a top-gate transistor array. These results represent substantial progress towards encoding electronic functionality through chemical synthesis and suggest the future promise of one-step integration of graphene-graphite based electronics.
Investigation of Radiation Effects on Semiconductor Devices and Integrated Circuits
1988-09-16
qualitativelysimilar to, and consistent with, findings at the two higher energies .) Results for irradiation of eightwhere q is the electronic charge, ni is the...COMMUNICATIONS R&D COMMAND ATTN: R BROWN ASSISTANT TO THE SECRETARY OF DEFENSE ATOMIC ENERGY U S ARMY ELECTRONIC TECH DEV LAB ATTN: EXECUTIVE ASSISTANT...Continue on reverse if necessary and identify by block number) Results of a study of radiation effects on electronic materials, devices, and integrated
Meesters, Kevin; Mauel, Reiner; Dhont, Evelyn; Walle, Johan Vande; De Bruyne, Pauline
2018-02-23
Fluoroquinolones (FQ) are increasingly prescribed for children, despite being labeled for only a limited number of labeled pediatric indications. In this multicenter retrospective drug utilization study, we analyzed indications for systemic FQ prescriptions in hospitalized children and the appropriateness of the prescribed dose. Using data obtained from electronic medical files, the study included all children who received a systemic FQ prescription in two Belgian university children's hospitals between 2010 and 2013. Two authors reviewed prescribed daily doses. Univariate and multivariate logistic regression models were used to analyze risk factors for inadequately dosing. Results262 FQ prescriptions for individual patients were included for analysis. 16.8% of these prescriptions were for labeled indications, and 35.1% were guided by bacteriological findings. Prescribed daily dose was considered to be inappropriate in 79 prescriptions (30.2%). Other FQ than ciprofloxacin accounted for 9 prescriptions (3.4%), of which 8 were correctly dosed. Underdosing represented 45 (56.9%) dosing errors. Infants and preschool children were at particular risk for dosing errors, with associated adjusted OR of 0.263 (0.097-0.701) and 0.254 (0.106-0.588) respectively. FQ were often prescribed off-label and not guided by bacteriological findings in our study population. Dosing errors were common, particularly in infants and preschool children. FQ prescriptions for children should be improved by specific pediatric antimicrobial stewardship teams. Furthermore, pharmacokinetic studies should optimise dosing recommendations for children.
Feynman Path Integral Approach to Electron Diffraction for One and Two Slits: Analytical Results
ERIC Educational Resources Information Center
Beau, Mathieu
2012-01-01
In this paper we present an analytic solution of the famous problem of diffraction and interference of electrons through one and two slits (for simplicity, only the one-dimensional case is considered). In addition to exact formulae, various approximations of the electron distribution are shown which facilitate the interpretation of the results.…
Social marketing-based communications to integrate and support the HEALTHY study intervention
USDA-ARS?s Scientific Manuscript database
The HEALTHY study was a randomized, controlled, multicenter, middle school-based, multifaceted intervention designed to reduce risk factors for the development of type 2 diabetes. The study randomized 42 middle schools to intervention or control, and followed students from the sixth to the eighth gr...
Morgan, Margie; Marlowe, Elizabeth; Della-Latta, Phyllis; Salimnia, Hossein; Novak-Weekley, Susan; Wu, Fann; Crystal, Benjamin S.
2010-01-01
A shortened protocol for two peptide nucleic acid fluorescence in situ hybridization (PNA FISH) assays for the detection of Gram-negative bacilli from positive blood cultures was evaluated in a multicenter trial. There was 100% concordance between the two protocols for each assay (368 of 368 and 370 of 370 results) and 99.7% (367 of 368 and 369 of 370 results) agreement with routine laboratory techniques. PMID:20357212
NASA Astrophysics Data System (ADS)
Lesiuk, Michał; Moszynski, Robert
2014-12-01
In this paper we consider the calculation of two-center exchange integrals over Slater-type orbitals (STOs). We apply the Neumann expansion of the Coulomb interaction potential and consider calculation of all basic quantities which appear in the resulting expression. Analytical closed-form equations for all auxiliary quantities have already been known but they suffer from large digital erosion when some of the parameters are large or small. We derive two differential equations which are obeyed by the most difficult basic integrals. Taking them as a starting point, useful series expansions for small parameter values or asymptotic expansions for large parameter values are systematically derived. The resulting expansions replace the corresponding analytical expressions when the latter introduce significant cancellations. Additionally, we reconsider numerical integration of some necessary quantities and present a new way to calculate the integrand with a controlled precision. All proposed methods are combined to lead to a general, stable algorithm. We perform extensive numerical tests of the introduced expressions to verify their validity and usefulness. Advances reported here provide methodology to compute two-electron exchange integrals over STOs for a broad range of the nonlinear parameters and large angular momenta.
Ribisl, Kurt M; Fernandez, Maria E; Friedman, Daniela B; Hannon, Peggy A; Leeman, Jennifer; Moore, Alexis; Olson, Lindsay; Ory, Marcia; Risendal, Betsy; Sheble, Laura; Taylor, Vicky M; Williams, Rebecca S; Weiner, Bryan J
2017-03-01
The Cancer Prevention and Control Research Network (CPCRN) is a thematic network dedicated to accelerating the adoption of evidence-based cancer prevention and control practices in communities by advancing dissemination and implementation science. Funded by the Centers for Disease Control and Prevention and National Cancer Institute, CPCRN has operated at two levels: Each participating network center conducts research projects with primarily local partners as well as multicenter collaborative research projects with state and national partners. Through multicenter collaboration, thematic networks leverage the expertise, resources, and partnerships of participating centers to conduct research projects collectively that might not be feasible individually. Although multicenter collaboration is often advocated, it is challenging to promote and assess. Using bibliometric network analysis and other graphical methods, this paper describes CPCRN's multicenter publication progression from 2004 to 2014. Searching PubMed, Scopus, and Web of Science in 2014 identified 249 peer-reviewed CPCRN publications involving two or more centers out of 6,534 total. The research and public health impact of these multicenter collaborative projects initiated by CPCRN during that 10-year period were then examined. CPCRN established numerous workgroups around topics such as: 2-1-1, training and technical assistance, colorectal cancer control, federally qualified health centers, cancer survivorship, and human papillomavirus. This paper discusses the challenges that arise in promoting multicenter collaboration and the strategies that CPCRN uses to address those challenges. The lessons learned should broadly interest those seeking to promote multisite collaboration to address public health problems, such as cancer prevention and control. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Habitat Demonstration Unit Project Leadership and Management Strategies
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project leadership and management strategies. The HDU project team constructed and tested an analog prototype lunar surface habitat/laboratory called the Pressurized Excursion Module (PEM) during 2010. The prototype unit subsystems were integrated in a short amount of time, utilizing a tiger team approach that brought together over 20 habitation-related technologies and innovations from a variety of NASA centers. This paper describes the leadership and management strategies as well as lessons learned pertaining to leading and managing a multi-center diverse team in a rapid prototype environment. The PEM configuration went from a paper design to an operational surface habitat demonstration unit in less than 12 months. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 HDU-Deep Space Habitat (DSH) configuration will build upon the PEM work, and emphasize validity of crew operations (remote working and living), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The 2011 HDU-DSH will be field-tested during the 2011 Desert Research and Technologies Studies (DRaTS) field tests. The HDU project is a "technology-pull" project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU 2010 demo unit that was field tested in the 2010 DRaTS, adding habitation functionality to the prototype unit. This paper will describe the strategy of establishing a multi-center project management team that put in place the key multi-center leadership skills and disciplines to enable a successful tiger team approach. Advocacy was established with key stakeholders and NASA Headquarters (HQ) by defining a strategic vision, mission, goals and objectives for the project and team. As a technology-pull testbed capability the HDU project was able to collaborate and leverage the Exploration Technology Development Program (ETDP) and individual NASA center investments which capitalized on their respective center core competencies and skills. This approach enable the leveraging of over $7.5m of value to create an operational habitat demonstration unit 2010 PEM configuration.
NASA Astrophysics Data System (ADS)
Lupei, A.; Lupei, V.; Hau, S.; Gheorghe, C.; Voicu, F.
2015-09-01
New spectroscopic data obtained from high resolution low temperature absorption and emission spectra of Nd3+ in mixed scandium aluminum garnets Y3ScxAl5-xO12 - (x = 0-2) translucent ceramics revealed transition dependent composition effects: modification of the shapes (Lorentz at x = 0 and 2, quasi-Gauss at x = 1, x-dependent asymmetric for other x values, with obvious multicenter structure for low x), widths and shifts of the lines. Nd3+ electronic structure dependence on structural changes with composition is analyzed in terms of nephelauxetic effect and maximum splitting of manifolds: Sc3+ co-doping reduces the nephelauxetic effect, and the increase of 4F3/2 splitting from 85 cm-1 (x = 0) to 98 cm-1 (x = 2) denotes the lowering of local symmetry. The multicenter structure and inhomogeneous broadening of Nd3+ lines is attributed to crystal field distributions determined by the random occupancy of the octahedral sites by Sc3+ and Al3+. For low x (0.2) the resolved two satellites S1, S2 that accompany Nd:YAG lines are correlated to anisotropic crystal field perturbations produced by the n.n. Sc3+ by analogy to those determined by Y3+-antisites (excess of Y3+ ions that enter in octahedral sites of the melt-grown YAG crystals). The temperature evolution of the Nd3+ spectral characteristics (line intensity, shift, broadening) in the 10-300 K range is analyzed in terms of thermal population of the Stark levels, of the effect on electron-phonon interaction and on lattice expansion. The relevance of the spectroscopic properties on the laser emission characteristics in these systems is discussed.
Atomic Calculations with a One-Parameter, Single Integral Method.
ERIC Educational Resources Information Center
Baretty, Reinaldo; Garcia, Carmelo
1989-01-01
Presents an energy function E(p) containing a single integral and one variational parameter, alpha. Represents all two-electron integrals within the local density approximation as a single integral. Identifies this as a simple treatment for use in an introductory quantum mechanics course. (MVL)
a Time-Dependent Many-Electron Approach to Atomic and Molecular Interactions
NASA Astrophysics Data System (ADS)
Runge, Keith
A new methodology is developed for the description of electronic rearrangement in atomic and molecular collisions. Using the eikonal representation of the total wavefunction, time -dependent equations are derived for the electronic densities within the time-dependent Hartree-Fock approximation. An averaged effective potential which ensures time reversal invariance is used to describe the effect of the fast electronic transitions on the slower nuclear motions. Electron translation factors (ETF) are introduced to eliminate spurious asymptotic couplings, and a local ETF is incorporated into a basis of traveling atomic orbitals. A reference density is used to describe local electronic relaxation and to account for the time propagation of fast and slow motions, and is shown to lead to an efficient integration scheme. Expressions for time-dependent electronic populations and polarization parameters are given. Electronic integrals over Gaussians including ETFs are derived to extend electronic state calculations to dynamical phenomena. Results of the method are in good agreement with experimental data for charge transfer integral cross sections over a projectile energy range of three orders of magnitude in the proton-Hydrogen atom system. The more demanding calculations of integral alignment, state-to-state integral cross sections, and differential cross sections are found to agree well with experimental data provided care is taken to include ETFs in the calculation of electronic integrals and to choose the appropriate effective potential. The method is found to be in good agreement with experimental data for the calculation of charge transfer integral cross sections and state-to-state integral cross sections in the one-electron heteronuclear Helium(2+)-Hydrogen atom system and in the two-electron system, Hydrogen atom-Hydrogen atom. Time-dependent electronic populations are seen to oscillate rapidly in the midst of collision event. In particular, multiple exchanges of the electron are seen to occur in the proton-Hydrogen atom system at low collision energies. The concepts and results derived from the approach provide new insight into the dynamics of nuclear screening and electronic rearrangement in atomic collisions.
Kim, Eun Young; Magnotta, Vincent A; Liu, Dawei; Johnson, Hans J
2014-09-01
Machine learning (ML)-based segmentation methods are a common technique in the medical image processing field. In spite of numerous research groups that have investigated ML-based segmentation frameworks, there remains unanswered aspects of performance variability for the choice of two key components: ML algorithm and intensity normalization. This investigation reveals that the choice of those elements plays a major part in determining segmentation accuracy and generalizability. The approach we have used in this study aims to evaluate relative benefits of the two elements within a subcortical MRI segmentation framework. Experiments were conducted to contrast eight machine-learning algorithm configurations and 11 normalization strategies for our brain MR segmentation framework. For the intensity normalization, a Stable Atlas-based Mapped Prior (STAMP) was utilized to take better account of contrast along boundaries of structures. Comparing eight machine learning algorithms on down-sampled segmentation MR data, it was obvious that a significant improvement was obtained using ensemble-based ML algorithms (i.e., random forest) or ANN algorithms. Further investigation between these two algorithms also revealed that the random forest results provided exceptionally good agreement with manual delineations by experts. Additional experiments showed that the effect of STAMP-based intensity normalization also improved the robustness of segmentation for multicenter data sets. The constructed framework obtained good multicenter reliability and was successfully applied on a large multicenter MR data set (n>3000). Less than 10% of automated segmentations were recommended for minimal expert intervention. These results demonstrate the feasibility of using the ML-based segmentation tools for processing large amount of multicenter MR images. We demonstrated dramatically different result profiles in segmentation accuracy according to the choice of ML algorithm and intensity normalization chosen. Copyright © 2014 Elsevier Inc. All rights reserved.
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
Cusack, Susan L; Jaros, Mark; Kuss, Michael; Minkowitz, Harold S; Winkle, Peter; Hemsen, Lisa
2012-01-01
XaraColl(®), a collagen-based implant that delivers bupivacaine to the site of surgical trauma, is under development for postoperative analgesia. Because of differing patient attitudes to postoperative pain control and the inability to assess baseline pain, standard clinical methods for evaluating analgesic efficacy are compromised and justify application of novel integrated approaches. We conducted two independent, multicenter, double-blind, placebo-controlled studies in men undergoing unilateral inguinal hernioplasty by open laparotomy to evaluate the safety and efficacy of XaraColl at different doses (100 mg and 200 mg of bupivacaine hydrochloride; study 1 and 2, respectively). Enrolled patients (50 in study 1 and 53 in study 2) were randomized to receive active or placebo implants in a 1:1 ratio. Postoperative pain intensity and use of supplementary opioid medication were recorded through 72 hours. Safety was assessed through 30 days. The principal efficacy variables were the summed pain intensity (SPI), total use of opioid analgesia (TOpA), and an integrated endpoint (I-SPI-TOpA). Each variable was analyzed at 24, 48, and 72 hours after implantation. A pooled analysis of both studies was also performed retrospectively. Through 24 and 48 hours, XaraColl-treated patients experienced significantly less pain in study 1 (P < 0.001 and P = 0.012, respectively) whereas they took significantly less opioid analgesia in study 2 (P = 0.004 and P = 0.042, respectively). Over the same time intervals in the pooled analysis, treated patients experienced both significantly less pain (P < 0.001 and P = 0.006, respectively) and took significantly less opioid analgesia (P = 0.001 and P = 0.024, respectively). The I-SPI-TOpA endpoint that combined both SPI and TOpA demonstrated a significant treatment effect through 72 hours in the pooled analysis (P = 0.021). XaraColl offers great potential for improving the management of postoperative pain and warrants further investigation in definitive clinical trials.
Conducting multicenter research in healthcare simulation: Lessons learned from the INSPIRE network.
Cheng, Adam; Kessler, David; Mackinnon, Ralph; Chang, Todd P; Nadkarni, Vinay M; Hunt, Elizabeth A; Duval-Arnould, Jordan; Lin, Yiqun; Pusic, Martin; Auerbach, Marc
2017-01-01
Simulation-based research has grown substantially over the past two decades; however, relatively few published simulation studies are multicenter in nature. Multicenter research confers many distinct advantages over single-center studies, including larger sample sizes for more generalizable findings, sharing resources amongst collaborative sites, and promoting networking. Well-executed multicenter studies are more likely to improve provider performance and/or have a positive impact on patient outcomes. In this manuscript, we offer a step-by-step guide to conducting multicenter, simulation-based research based upon our collective experience with the International Network for Simulation-based Pediatric Innovation, Research and Education (INSPIRE). Like multicenter clinical research, simulation-based multicenter research can be divided into four distinct phases. Each phase has specific differences when applied to simulation research: (1) Planning phase , to define the research question, systematically review the literature, identify outcome measures, and conduct pilot studies to ensure feasibility and estimate power; (2) Project Development phase , when the primary investigator identifies collaborators, develops the protocol and research operations manual, prepares grant applications, obtains ethical approval and executes subsite contracts, registers the study in a clinical trial registry, forms a manuscript oversight committee, and conducts feasibility testing and data validation at each site; (3) Study Execution phase , involving recruitment and enrollment of subjects, clear communication and decision-making, quality assurance measures and data abstraction, validation, and analysis; and (4) Dissemination phase , where the research team shares results via conference presentations, publications, traditional media, social media, and implements strategies for translating results to practice. With this manuscript, we provide a guide to conducting quantitative multicenter research with a focus on simulation-specific issues.
Fang, Jianqiao; Chen, Lifang; Ma, Ruijie; Keeler, Crystal Lynn; Shen, Laihua; Bao, Yehua; Xu, Shouyu
2016-01-01
To determine whether integrative medicine rehabilitation (IMR) that combines conventional rehabilitation (CR) with acupuncture and Chinese herbal medicine has better effects for subacute stroke than CR alone, we conducted a multicenter randomized controlled trial that involved three hospitals in China. Three hundred sixty patients with subacute stroke were randomized into IMR and CR groups. The primary outcome was the Modified Barthel Index (MBI). The secondary outcomes were the National Institutes of Health Stroke Scale (NIHSS), the Fugl-Meyer Assessment (FMA), the mini-mental state examination (MMSE), the Montreal Cognitive Assessment (MoCA), Hamilton’s Depression Scale (HAMD), and the Self-Rating Depression Scale (SDS). All variables were evaluated at week 0 (baseline), week 4 (half-way of intervention), week 8 (after treatment) and week 20 (follow-up). In comparison with the CR group, the IMR group had significantly better improvements (P < 0.01 or P < 0.05) in all the primary and secondary outcomes. There were also significantly better changes from baseline in theses outcomes in the IMR group than in the CR group (P < 0.01). A low incidence of adverse events with mild symptoms was observed in the IMR group. We conclude that conventional rehabilitation combined with integrative medicine is safe and more effective for subacute stroke rehabilitation. PMID:27174221
Zhong, Rong-Lin; Xu, Hong-Liang; Li, Zhi-Ru
2016-08-07
An increasing number of chemists have focused on the two-electron/multicenter bond (2e/mc) that was first introduced to interpret the bonding mechanism of radical dimers. Herein, we report the polar two-electron/twelve center (2e/12c) bonding character in a series of phenalenyl-azaphenalenyl radical hetero-dimers. Interestingly, the bonding energy of weaker polar hetero-dimer (P-TAP) is dominated by the overlap of the two different singly occupied molecular orbital of radicals, while that of stronger polar hetero-dimer (P-HAP) is dominated by the electrostatic attraction. Results show that the difference between the electronegativity of the monomers plays a prominent role in the essential attribution of the polar 2e/12c bond. Correspondingly, a stronger stacking interaction in the hetero-dimer could be effectively achieved by increasing the difference of nitrogen atoms number between the monomers. It is worthy of note that an interesting interlayer charge transfer character is induced in the polar hetero-dimers, which is dependent on the difference between the electronegativity of the monomers. It is our expectation that the new knowledge about the bonding nature of radical hetero-dimers might provide important information for designing radical based functional materials with various applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Rong-Lin; Li, Zhi-Ru, E-mail: hlxu@nenu.edu.cn, E-mail: lzr@jlu.edu.cn; Xu, Hong-Liang, E-mail: hlxu@nenu.edu.cn, E-mail: lzr@jlu.edu.cn
An increasing number of chemists have focused on the two-electron/multicenter bond (2e/mc) that was first introduced to interpret the bonding mechanism of radical dimers. Herein, we report the polar two-electron/twelve center (2e/12c) bonding character in a series of phenalenyl-azaphenalenyl radical hetero-dimers. Interestingly, the bonding energy of weaker polar hetero-dimer (P-TAP) is dominated by the overlap of the two different singly occupied molecular orbital of radicals, while that of stronger polar hetero-dimer (P-HAP) is dominated by the electrostatic attraction. Results show that the difference between the electronegativity of the monomers plays a prominent role in the essential attribution of the polarmore » 2e/12c bond. Correspondingly, a stronger stacking interaction in the hetero-dimer could be effectively achieved by increasing the difference of nitrogen atoms number between the monomers. It is worthy of note that an interesting interlayer charge transfer character is induced in the polar hetero-dimers, which is dependent on the difference between the electronegativity of the monomers. It is our expectation that the new knowledge about the bonding nature of radical hetero-dimers might provide important information for designing radical based functional materials with various applications.« less
Integrated feeds for electronically reconfigurable apertures
NASA Astrophysics Data System (ADS)
Nicholls, Jeffrey Grant
With the increasing ubiquity of wireless technology, the need for lower-profile, electronically reconfigurable, highly-directive beam-steering antennas is increasing. This thesis proposes a new electronic beam-steering antenna architecture which combines the full-space beam-steering properties of reflectarrays and transmitarrays with the low-profile feeding characteristics of leaky-wave antennas. Two designs are developed: an integrated feed reflectarray and an integrated feed transmitarray, both of which integrate a leaky-wave feed directly next to the reconfigurable aperture itself. The integrated feed transmitarray proved to be the better architecture due to its simpler design and better performance. A 6-by-6 element array was fabricated and experimentally verified, and full-space (both azimuth and elevation) beam-steering was demonstrated at angles up to 45 degrees off broadside. In addition to the reduction in profile, the integrated feed design enables robust fixed control of the amplitude distribution across the aperture, a characteristic not as easily attained in typical reflectarrays/transmitarrays.
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-03-31
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ∼3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics.
NASA Astrophysics Data System (ADS)
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-03-01
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ~3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics.
Shin, Sung-Ho; Ji, Sangyoon; Choi, Seiho; Pyo, Kyoung-Hee; Wan An, Byeong; Park, Jihun; Kim, Joohee; Kim, Ju-Young; Lee, Ki-Suk; Kwon, Soon-Yong; Heo, Jaeyeong; Park, Byong-Guk; Park, Jang-Ung
2017-01-01
Integrated electronic circuitries with pressure sensors have been extensively researched as a key component for emerging electronics applications such as electronic skins and health-monitoring devices. Although existing pressure sensors display high sensitivities, they can only be used for specific purposes due to the narrow range of detectable pressure (under tens of kPa) and the difficulty of forming highly integrated arrays. However, it is essential to develop tactile pressure sensors with a wide pressure range in order to use them for diverse application areas including medical diagnosis, robotics or automotive electronics. Here we report an unconventional approach for fabricating fully integrated active-matrix arrays of pressure-sensitive graphene transistors with air-dielectric layers simply formed by folding two opposing panels. Furthermore, this realizes a wide tactile pressure sensing range from 250 Pa to ∼3 MPa. Additionally, fabrication of pressure sensor arrays and transparent pressure sensors are demonstrated, suggesting their substantial promise as next-generation electronics. PMID:28361867
NASA Technical Reports Server (NTRS)
Baer-Riedhart, Jennifer L.; Landy, Robert J.
1987-01-01
The highly integrated digital electronic control (HIDEC) program at NASA Ames Research Center, Dryden Flight Research Facility is a multiphase flight research program to quantify the benefits of promising integrated control systems. McDonnell Aircraft Company is the prime contractor, with United Technologies Pratt and Whitney Aircraft, and Lear Siegler Incorporated as major subcontractors. The NASA F-15A testbed aircraft was modified by the HIDEC program by installing a digital electronic flight control system (DEFCS) and replacing the standard F100 (Arab 3) engines with F100 engine model derivative (EMD) engines equipped with digital electronic engine controls (DEEC), and integrating the DEEC's and DEFCS. The modified aircraft provides the capability for testing many integrated control modes involving the flight controls, engine controls, and inlet controls. This paper focuses on the first two phases of the HIDEC program, which are the digital flight control system/aircraft model identification (DEFCS/AMI) phase and the adaptive engine control system (ADECS) phase.
Hoy, Erik P; Mazziotti, David A
2015-08-14
Tensor factorization of the 2-electron integral matrix is a well-known technique for reducing the computational scaling of ab initio electronic structure methods toward that of Hartree-Fock and density functional theories. The simplest factorization that maintains the positive semidefinite character of the 2-electron integral matrix is the Cholesky factorization. In this paper, we introduce a family of positive semidefinite factorizations that generalize the Cholesky factorization. Using an implementation of the factorization within the parametric 2-RDM method [D. A. Mazziotti, Phys. Rev. Lett. 101, 253002 (2008)], we study several inorganic molecules, alkane chains, and potential energy curves and find that this generalized factorization retains the accuracy and size extensivity of the Cholesky factorization, even in the presence of multi-reference correlation. The generalized family of positive semidefinite factorizations has potential applications to low-scaling ab initio electronic structure methods that treat electron correlation with a computational cost approaching that of the Hartree-Fock method or density functional theory.
Lin, Qisheng; Miller, Gordon J
2018-01-16
Intermetallic compounds represent an extensive pool of candidates for energy related applications stemming from magnetic, electric, optic, caloric, and catalytic properties. The discovery of novel intermetallic compounds can enhance understanding of the chemical principles that govern structural stability and chemical bonding as well as finding new applications. Valence electron-poor polar intermetallics with valence electron concentrations (VECs) between 2.0 and 3.0 e - /atom show a plethora of unprecedented and fascinating structural motifs and bonding features. Therefore, establishing simple structure-bonding-property relationships is especially challenging for this compound class because commonly accepted valence electron counting rules are inappropriate. During our efforts to find quasicrystals and crystalline approximants by valence electron tuning near 2.0 e - /atom, we observed that compositions close to those of quasicrystals are exceptional sources for unprecedented valence electron-poor polar intermetallics, e.g., Ca 4 Au 10 In 3 containing (Au 10 In 3 ) wavy layers, Li 14.7 Mg 36.8 Cu 21.5 Ga 66 adopting a type IV clathrate framework, and Sc 4 Mg x Cu 15-x Ga 7.5 that is incommensurately modulated. In particular, exploratory syntheses of AAu 3 T (A = Ca, Sr, Ba and T = Ge, Sn) phases led to interesting bonding features for Au, such as columns, layers, and lonsdaleite-type tetrahedral frameworks. Overall, the breadth of Au-rich polar intermetallics originates, in part, from significant relativistics effect on the valence electrons of Au, effects which result in greater 6s/5d orbital mixing, a small effective metallic radius, and an enhanced Mulliken electronegativity, all leading to ultimate enhanced binding with nearly all metals including itself. Two other successful strategies to mine electron-poor polar intermetallics include lithiation and "cation-rich" phases. Along these lines, we have studied lithiated Zn-rich compounds in which structural complexity can be realized by small amounts of Li replacing Zn atoms in the parent binary compounds CaZn 2 , CaZn 3 , and CaZn 5 ; their phase formation and bonding schemes can be rationalized by Fermi surface-Brillouin zone interactions between nearly free-electron states. "Cation-rich", electron-poor polar intermetallics have emerged using rare earth metals as the electropositive ("cationic") component together metal/metalloid clusters that mimic the backbones of aromatic hydrocarbon molecules, which give evidence of extensive electronic delocalization and multicenter bonding. Thus, we can identify three distinct, valence electron-poor, polar intermetallic systems that have yielded unprecedented phases adopting novel structures containing complex clusters and intriguing bonding characteristics. In this Account, we summarize our recent specific progress in the developments of novel Au-rich BaAl 4 -type related structures, shown in the "gold-rich grid", lithiation-modulated Ca-Li-Zn phases stabilized by different bonding characteristics, and rare earth-rich polar intermetallics containing unprecedented hydrocarbon-like planar Co-Ge metal clusters and pronounced delocalized multicenter bonding. We will focus mainly on novel structural motifs, bonding analyses, and the role of valence electrons for phase stability.
Rahman, Mahabubur; Watabe, Hiroshi
2018-05-01
Molecular imaging serves as an important tool for researchers and clinicians to visualize and investigate complex biochemical phenomena using specialized instruments; these instruments are either used individually or in combination with targeted imaging agents to obtain images related to specific diseases with high sensitivity, specificity, and signal-to-noise ratios. However, molecular imaging, which is a multidisciplinary research field, faces several challenges, including the integration of imaging informatics with bioinformatics and medical informatics, requirement of reliable and robust image analysis algorithms, effective quality control of imaging facilities, and those related to individualized disease mapping, data sharing, software architecture, and knowledge management. As a cost-effective and open-source approach to address these challenges related to molecular imaging, we develop a flexible, transparent, and secure infrastructure, named MIRA, which stands for Molecular Imaging Repository and Analysis, primarily using the Python programming language, and a MySQL relational database system deployed on a Linux server. MIRA is designed with a centralized image archiving infrastructure and information database so that a multicenter collaborative informatics platform can be built. The capability of dealing with metadata, image file format normalization, and storing and viewing different types of documents and multimedia files make MIRA considerably flexible. With features like logging, auditing, commenting, sharing, and searching, MIRA is useful as an Electronic Laboratory Notebook for effective knowledge management. In addition, the centralized approach for MIRA facilitates on-the-fly access to all its features remotely through any web browser. Furthermore, the open-source approach provides the opportunity for sustainable continued development. MIRA offers an infrastructure that can be used as cross-boundary collaborative MI research platform for the rapid achievement in cancer diagnosis and therapeutics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ferrada, Paula; Callcut, Rachael; Zielinski, Martin D; Bruns, Brandon; Yeh, Daniel Dante; Zakrison, Tanya L; Meizoso, Jonathan P; Sarani, Babak; Catalano, Richard D; Kim, Peter; Plant, Valerie; Pasley, Amelia; Dultz, Linda A; Choudhry, Asad J; Haut, Elliott R
2017-07-01
The mortality of patients with Clostridium difficile-associated disease (CDAD) requiring surgery continues to be very high. Loop ileostomy (LI) was introduced as an alternative procedure to total colectomy (TC) for CDAD by a single-center study. To date, no reproducible results have been published. The objective of this study was to compare these two procedures in a multicentric approach to help the surgeon decide what procedure is best suited for the patient in need. This was a retrospective multicenter study conducted under the sponsorship of the Eastern Association for the Surgery of Trauma. Demographics, medical history, clinical presentation, APACHE score, and outcomes were collected. We used the Research Electronic Data Capture tool to store the data. Mann-Whitney (continuous data) and Fisher exact (categorical data) were used to compare TC with LI. Logistic regression was performed to determine predictors of mortality. A propensity score analysis was done to control for potential confounders and determine adjusted mortality rates by procedure type. We collected data from 10 centers of patients who presented with CDAD requiring surgery between July 1, 2010 and July 30, 2014. Two patients died during the surgical procedure, leaving 98 individuals in the study. The overall mortality was 32%, and 75% had postoperative complications. Median age was 64.5 years; 59% were male. Concerning preoperative patient conditions, 54% were on pressors, 47% had renal failure, and 36% had respiratory failure. When comparing TC and LI, there was no statistical difference regarding these conditions. Univariate preprocedure predictors of mortality were age, lactate, timing of operation, vasopressor use, and acute renal failure. There was no statistical difference between the APACHE score of patients undergoing either procedure (TC, 22 vs LI, 16). Adjusted mortality (controlled for preprocedure confounders) was significantly lower in the LI group (17.2% vs 39.7%; p = 0.002). This is the first multicenter study comparing TC with LI for the treatment of CDAD. In this study, LI carried less mortality than TC. In patients without contraindications, LI should be considered for the surgical treatment of CDAD. Therapeutic study, level III.
Stauffer, Virginia L.; Baygani, Simin K.; Kinon, Bruce J.; Krikke-Workel, Judith O.
2014-01-01
Abstract This 6-week, multicenter, randomized withdrawal, placebo-controlled trial sought to determine whether symptoms of physical dependence occur after abrupt cessation of pomaglumetad methionil (LY2140023 monohydrate), a metabotropic glutamate 2/3 receptor agonist, in patients with schizophrenia. Eligible outpatients, 18 to 65 years old who required a modification or initiation of antipsychotic medication received 4 weeks of pomaglumetad methionil during open-label treatment and then were randomized, double-blind, to continue pomaglumetad methionil or receive placebo for 2 weeks. The primary outcome compared results of the 3-day moving mean of the total score on the Discontinuation Symptom Checklist-Modified Rickels for pomaglumetad methionil-treated patients with those on placebo during the randomized withdrawal phase. An electronic patient-reported outcome (ePRO) device was used daily to record these results. During the withdrawal phase, 103 patients were randomized, and 98 patients completed the trial. There was no statistically significant evidence of withdrawal symptoms associated with placebo compared with pomaglumetad methionil continuation as measured by Discontinuation Symptom Checklist-Modified Rickels (P = 0.170). The results are supported by secondary analyses with the clinician-rated, Clinical Institute Withdrawal Assessment of Alcohol Scale Revised, which showed no statistically significant differences between treatment groups. Using the ePRO device, 82.5% of the patients achieved 75% to 100% of compliance. No discontinuations due to worsening of schizophrenia, serious adverse events, deaths, or seizures were reported during either phase of the study. These findings suggest that there is no evidence of withdrawal symptoms associated with the abrupt discontinuation of pomaglumetad methionil and that an ePRO device can be successfully used in a multicenter schizophrenia trial. PMID:25006819
Thermal electron heating rate: A derivation
NASA Technical Reports Server (NTRS)
Hoegy, W. R.
1983-01-01
The thermal electron heating rate is an important heat source term in the ionospheric electron energy balance equation, representing heating by photoelectrons or by precipitating higher energy electrons. A formula for the thermal electron heating rate is derived from the kinetic equation using the electron-electron collision operator as given by the unified theory of Kihara and Aono. This collision operator includes collective interactions to produce a finite collision operator with an exact Coulomb logarithm term. The derived heating rate O(e) is the sum of three terms, O(e) = O(p) + S + O(int), which are respectively: (1) primary electron production term giving the heating from newly created electrons that have not yet suffered collisions with the ambient electrons; (2) a heating term evaluated on the energy surface m(e)/2 = E(T) at the transition between Maxwellian and tail electrons at E(T); and (3) the integral term representing heating of Maxwellian electrons by energetic tail electrons at energies ET. Published ionospheric electron temperature studies used only the integral term O(int) with differing lower integration limits. Use of the incomplete heating rate could lead to erroneous conclusions regarding electron heat balance, since O(e) is greater than O(int) by as much as a factor of two.
ERIC Educational Resources Information Center
Chief of Naval Education and Training Support, Pensacola, FL.
This individualized learning module on linear integrated circuits is one in a series of modules for a course in basic electricity and electronics. The course is one of a number of military-developed curriculum packages selected for adaptation to vocational instructional and curriculum development in a civilian setting. Two lessons are included in…
Harton, Brenda B; Borrelli, Larry; Knupp, Ann; Rogers, Necolen; West, Vickie R
2009-01-01
Traditional nursing service orientation classes at an acute care hospital were integrated with orientation to the electronic medical record to blend the two components in a user-friendly format so that the learner is introduced to the culture, processes, and documentation methods of the organization, with an opportunity to document online in a practice domain while lecture and discussion information is fresh.
AlJarullah, Asma; El-Masri, Samir
2013-08-01
The goal of a national electronic health records integration system is to aggregate electronic health records concerning a particular patient at different healthcare providers' systems to provide a complete medical history of the patient. It holds the promise to address the two most crucial challenges to the healthcare systems: improving healthcare quality and controlling costs. Typical approaches for the national integration of electronic health records are a centralized architecture and a distributed architecture. This paper proposes a new approach for the national integration of electronic health records, the semi-centralized approach, an intermediate solution between the centralized architecture and the distributed architecture that has the benefits of both approaches. The semi-centralized approach is provided with a clearly defined architecture. The main data elements needed by the system are defined and the main system modules that are necessary to achieve an effective and efficient functionality of the system are designed. Best practices and essential requirements are central to the evolution of the proposed architecture. The proposed architecture will provide the basis for designing the simplest and the most effective systems to integrate electronic health records on a nation-wide basis that maintain integrity and consistency across locations, time and systems, and that meet the challenges of interoperability, security, privacy, maintainability, mobility, availability, scalability, and load balancing.
NASA Astrophysics Data System (ADS)
Ji, Pengfei; Zhang, Yuwen
2016-03-01
On the basis of ab initio quantum mechanics (QM) calculation, the obtained electron heat capacity is implemented into energy equation of electron subsystem in two temperature model (TTM). Upon laser irradiation on the copper film, energy transfer from the electron subsystem to the lattice subsystem is modeled by including the electron-phonon coupling factor in molecular dynamics (MD) and TTM coupled simulation. The results show temperature and thermal melting difference between the QM-MD-TTM integrated simulation and pure MD-TTM coupled simulation. The successful construction of the QM-MD-TTM integrated simulation provides a general way that is accessible to other metals in laser heating.
Koop, A; Gatermann, C; Mösges, R
2000-01-01
Our purpose was to determine conditions, under which the use of hand-held computers in the diagnosis and therapy of patients with chronic diseases seems to be handy. Two scenarios are presented showing the employment of these computers in a doctor's office and in multicenter clinical trials. Security-related aspects involved in transferring medical data via the internet are discussed.
Brama, Elisabeth; Peddie, Christopher J; Wilkes, Gary; Gu, Yan; Collinson, Lucy M; Jones, Martin L
2016-12-13
In-resin fluorescence (IRF) protocols preserve fluorescent proteins in resin-embedded cells and tissues for correlative light and electron microscopy, aiding interpretation of macromolecular function within the complex cellular landscape. Dual-contrast IRF samples can be imaged in separate fluorescence and electron microscopes, or in dual-modality integrated microscopes for high resolution correlation of fluorophore to organelle. IRF samples also offer a unique opportunity to automate correlative imaging workflows. Here we present two new locator tools for finding and following fluorescent cells in IRF blocks, enabling future automation of correlative imaging. The ultraLM is a fluorescence microscope that integrates with an ultramicrotome, which enables 'smart collection' of ultrathin sections containing fluorescent cells or tissues for subsequent transmission electron microscopy or array tomography. The miniLM is a fluorescence microscope that integrates with serial block face scanning electron microscopes, which enables 'smart tracking' of fluorescent structures during automated serial electron image acquisition from large cell and tissue volumes.
Interchange of electronic design through VHDL and EIS
NASA Technical Reports Server (NTRS)
Wallace, Richard M.
1987-01-01
The need for both robust and unambiguous electronic designs is a direct requirement of the astonishing growth in design and manufacturing capability during recent years. In order to manage the plethora of designs, and have the design data both interchangeable and interoperable, the Very High Speed Integrated Circuits (VHSIC) program is developing two major standards for the electronic design community. The VHSIC Hardware Description Language (VHDL) is designed to be the lingua franca for transmission of design data between designers and their environments. The Engineering Information System (EIS) is designed to ease the integration of data betweeen diverse design automation systems. This paper describes the rationale for the necessity for these two standards and how they provide a synergistic expressive capability across the macrocosm of design environments.
LETTER TO THE EDITOR: Two-centre exchange integrals for complex exponent Slater orbitals
NASA Astrophysics Data System (ADS)
Kuang, Jiyun; Lin, C. D.
1996-12-01
The one-dimensional integral representation for the Fourier transform of a two-centre product of B functions (finite linear combinations of Slater orbitals) with real parameters is generalized to include B functions with complex parameters. This one-dimensional integral representation allows for an efficient method of calculating two-centre exchange integrals with plane-wave electronic translational factors (ETF) over Slater orbitals of real/complex exponents. This method is a significant improvement on the previous two-dimensional quadrature method of the integrals. A new basis set of the form 0953-4075/29/24/005/img1 is proposed to improve the description of pseudo-continuum states in the close-coupling treatment of ion - atom collisions.
Electronically Tunable Differential Integrator: Linear Voltage Controlled Quadrature Oscillator.
Nandi, Rabindranath; Pattanayak, Sandhya; Venkateswaran, Palaniandavar; Das, Sagarika
2015-01-01
A new electronically tunable differential integrator (ETDI) and its extension to voltage controlled quadrature oscillator (VCQO) design with linear tuning law are proposed; the active building block is a composite current feedback amplifier with recent multiplication mode current conveyor (MMCC) element. Recently utilization of two different kinds of active devices to form a composite building block is being considered since it yields a superior functional element suitable for improved quality circuit design. The integrator time constant (τ) and the oscillation frequency (ω o ) are tunable by the control voltage (V) of the MMCC block. Analysis indicates negligible phase error (θ e ) for the integrator and low active ω o -sensitivity relative to the device parasitic capacitances. Satisfactory experimental verifications on electronic tunability of some wave shaping applications by the integrator and a double-integrator feedback loop (DIFL) based sinusoid oscillator with linear f o variation range of 60 KHz~1.8 MHz at low THD of 2.1% are verified by both simulation and hardware tests.
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Toup, Larry; Gill, Tracy; Tri, Terry; Howe, Scott; Smitherman, David
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project leadership and management strategies being used by the NASA HDU team for a rapid prototyping project. The HDU project team constructed and tested an analog prototype lunar surface habitat/laboratory called the Pressurized Excursion Module (PEM) during 2010. The prototype unit subsystems were integrated in a short amount of time, utilizing a tiger team rapid prototyping approach that brought together over 20 habitation-related technologies and innovations from a variety of NASA centers. This paper describes the leadership and management strategies as well as lessons learned pertaining to leading and managing a multi-center diverse team in a rapid prototype environment. The PEM configuration went from a paper design to an operational surface habitat demonstration unit in less than 12 months. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 HDU-Deep Space Habitat (DSH) configuration will build upon the PEM work, and emphasize validity of crew operations (remote working and living), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The 2011 HDU-DSH will be field-tested during the 2011 Desert Research and Technologies Studies (DRaTS) field tests. The HDU project is a "technology-pull" project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU 2010 demo unit that was field tested in the 2010 DRaTS, adding habitation functionality to the prototype unit. This paper will describe the strategy of establishing a multi-center project management team that put in place the key multi-center leadership skills and disciplines to enable a successful tiger team approach. Advocacy was established with key stakeholders and NASA Headquarters (HQ) by defining a strategic vision, mission, goals and objectives for the project and team. As a technology-pull testbed capability the HDU project was able to collaborate and leverage the Exploration Technology Development Program (ETDP) and individual NASA center investments which capitalized on their respective center core competencies and skills. This approach enable the leveraging of over $7.5m of value to create an operational habitat demonstration unit 2010 PEM configuration.
Cambiaghi, Alice; Díaz, Ramón; Martinez, Julia Bauzá; Odena, Antonia; Brunelli, Laura; Caironi, Pietro; Masson, Serge; Baselli, Giuseppe; Ristagno, Giuseppe; Gattinoni, Luciano; de Oliveira, Eliandre; Pastorelli, Roberta; Ferrario, Manuela
2018-04-27
In this work, we examined plasma metabolome, proteome and clinical features in patients with severe septic shock enrolled in the multicenter ALBIOS study. The objective was to identify changes in the levels of metabolites involved in septic shock progression and to integrate this information with the variation occurring in proteins and clinical data. Mass spectrometry-based targeted metabolomics and untargeted proteomics allowed us to quantify absolute metabolites concentration and relative proteins abundance. We computed the ratio D7/D1 to take into account their variation from day 1 (D1) to day 7 (D7) after shock diagnosis. Patients were divided into two groups according to 28-day mortality. Three different elastic net logistic regression models were built: one on metabolites only, one on metabolites and proteins and one to integrate metabolomics and proteomics data with clinical parameters. Linear discriminant analysis and Partial least squares Discriminant Analysis were also implemented. All the obtained models correctly classified the observations in the testing set. By looking at the variable importance (VIP) and the selected features, the integration of metabolomics with proteomics data showed the importance of circulating lipids and coagulation cascade in septic shock progression, thus capturing a further layer of biological information complementary to metabolomics information.
Integrated Nationwide Electronic Health Records system: Semi-distributed architecture approach.
Fragidis, Leonidas L; Chatzoglou, Prodromos D; Aggelidis, Vassilios P
2016-11-14
The integration of heterogeneous electronic health records systems by building an interoperable nationwide electronic health record system provides undisputable benefits in health care, like superior health information quality, medical errors prevention and cost saving. This paper proposes a semi-distributed system architecture approach for an integrated national electronic health record system incorporating the advantages of the two dominant approaches, the centralized architecture and the distributed architecture. The high level design of the main elements for the proposed architecture is provided along with diagrams of execution and operation and data synchronization architecture for the proposed solution. The proposed approach effectively handles issues related to redundancy, consistency, security, privacy, availability, load balancing, maintainability, complexity and interoperability of citizen's health data. The proposed semi-distributed architecture offers a robust interoperability framework without healthcare providers to change their local EHR systems. It is a pragmatic approach taking into account the characteristics of the Greek national healthcare system along with the national public administration data communication network infrastructure, for achieving EHR integration with acceptable implementation cost.
NASA Technical Reports Server (NTRS)
Powers, Sheryll Goecke (Compiler)
1995-01-01
Flight research for the F-15 HIDEC (Highly Integrated Digital Electronic Control) program was completed at NASA Dryden Flight Research Center in the fall of 1993. The flight research conducted during the last two years of the HIDEC program included two principal experiments: (1) performance seeking control (PSC), an adaptive, real-time, on-board optimization of engine, inlet, and horizontal tail position on the F-15; and (2) propulsion controlled aircraft (PCA), an augmented flight control system developed for landings as well as up-and-away flight that used only engine thrust (flight controls locked) for flight control. In September 1994, the background details and results of the PSC and PCA experiments were presented in an electronic workshop, accessible through the Dryden World Wide Web (http://www.dfrc.nasa.gov/dryden.html) and as a compact disk.
Magnetism of metallacrown single-molecule magnets: From a simplest model to realistic systems
NASA Astrophysics Data System (ADS)
Pavlyukh, Y.; Rentschler, E.; Elmers, H. J.; Hübner, W.; Lefkidis, G.
2018-06-01
Electronic and magnetic properties of molecular nanomagnets are determined by competing energy scales due to the crystal field splitting, the exchange interactions between transition metal atoms, and relativistic effects. We present a comprehensive theory embracing all these phenomena based on first-principles calculations. In order to achieve this goal, we start from the FeNi4 cluster as a paradigm. The system can be accurately described on the ab initio level yielding all expected electronic states in a range of multiplicities from 1 to 9, with a ferromagnetic ground state. By adding the spin-orbit coupling between them we obtain the zero-field splitting. This allows to introduce a spin Hamiltonian of a giant spin model, which operates on a smaller energy scale. We compare the computed parameters of this Hamiltonian with the experimental and theoretical magnetic anisotropy energies of the monolayer Ni/Cu(001). In line with them, we find that the anisotropy almost entirely originates from the second-order spin-orbit coupling, the spin-spin coupling constitutes only a small fraction. Finally, we include the ligand atoms in our consideration. This component has a decisive role for the stabilization of molecules in experimental synthesis and characterization, and also substantially complicates the theory by bringing the superexchange mechanisms into play. Since they are higher-order effects involving two hopping matrix elements, not every theory can describe them. Our generalization of the corresponding perturbation theory substantiates the use of complete active space methods for the description of superexchange. At the same time, our numerical results for the {CuFe4} system demonstrate that the Goodenough-Kanamori rules, which are often used to determine the sign of these exchange interactions, cannot deliver quantitative predictions due to the interplay of other mechanisms, e. g., involving multicenter Coulomb integrals. We conclude by comparing ab initio values of the exchange interaction constants for the {CuCu4} and {CuFe4} metallacrown magnetic molecules with experimental values determined by fitting of the magnetic susceptibility curves χMT (T ) , and attribute the remaining discrepancy between them to the role of virtual electron excitations into and out of the active space (dynamical correlations).
NASA Astrophysics Data System (ADS)
Filatov, Michael; Cremer, Dieter
2005-02-01
The regular approximation to the normalized elimination of the small component (NESC) in the modified Dirac equation has been developed and presented in matrix form. The matrix form of the infinite-order regular approximation (IORA) expressions, obtained in [Filatov and Cremer, J. Chem. Phys. 118, 6741 (2003)] using the resolution of the identity, is the exact matrix representation and corresponds to the zeroth-order regular approximation to NESC (NESC-ZORA). Because IORA (=NESC-ZORA) is a variationally stable method, it was used as a suitable starting point for the development of the second-order regular approximation to NESC (NESC-SORA). As shown for hydrogenlike ions, NESC-SORA energies are closer to the exact Dirac energies than the energies from the fifth-order Douglas-Kroll approximation, which is much more computationally demanding than NESC-SORA. For the application of IORA (=NESC-ZORA) and NESC-SORA to many-electron systems, the number of the two-electron integrals that need to be evaluated (identical to the number of the two-electron integrals of a full Dirac-Hartree-Fock calculation) was drastically reduced by using the resolution of the identity technique. An approximation was derived, which requires only the two-electron integrals of a nonrelativistic calculation. The accuracy of this approach was demonstrated for heliumlike ions. The total energy based on the approximate integrals deviates from the energy calculated with the exact integrals by less than 5×10-9hartree units. NESC-ZORA and NESC-SORA can easily be implemented in any nonrelativistic quantum chemical program. Their application is comparable in cost with that of nonrelativistic methods. The methods can be run with density functional theory and any wave function method. NESC-SORA has the advantage that it does not imply a picture change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orlenko, E. V., E-mail: eorlenko@mail.ru; Evstafev, A. V.; Orlenko, F. E.
A formalism of exchange perturbation theory (EPT) is developed for the case of interactions that explicitly depend on time. Corrections to the wave function obtained in any order of perturbation theory and represented in an invariant form include exchange contributions due to intercenter electron permutations in complex multicenter systems. For collisions of atomic systems with an arbitrary type of interaction, general expressions are obtained for the transfer (T) and scattering (S) matrices in which intercenter electron permutations between overlapping nonorthogonal states belonging to different centers (atoms) are consistently taken into account. The problem of collision of alpha particles with lithiummore » atoms accompanied by the redistribution of electrons between centers is considered. The differential and total charge-exchange cross sections of lithium are calculated.« less
Orozco-Beltran, Domingo; Ruescas-Escolano, Esther; Navarro-Palazón, Ana Isabel; Cordero, Alberto; Gaubert-Tortosa, María; Navarro-Perez, Jorge; Carratalá-Munuera, Concepción; Pertusa-Martínez, Salvador; Soler-Bahilo, Enrique; Brotons-Muntó, Francisco; Bort-Cubero, Jose; Nuñez-Martinez, Miguel Angel; Bertomeu-Martinez, Vicente; Gil-Guillen, Vicente Francisco
2013-08-02
To evaluate the effectiveness of a new multifactorial intervention to improve health care for chronic ischemic heart disease patients in primary care. The strategy has two components: a) organizational for the patient/professional relationship and b) training for professionals. Experimental study. Randomized clinical trial. Follow-up period: one year. primary care, multicenter (15 health centers). For the intervention group 15 health centers are selected from those participating in ESCARVAL study. Once the center agreed to participate patients are randomly selected from the total amount of patients with ischemic heart disease registered in the electronic health records. For the control group a random sample of patients with ischemic heart disease is selected from all 72 health centers electronic records. This study aims to evaluate the efficacy of a multifactorial intervention strategy involving patients with ischemic heart disease for the improvement of the degree of control of the cardiovascular risk factors and of the quality of life, number of visits, and number of hospitalizations. NCT01826929.
Advanced Electronics. Curriculum Development. Bulletin 1778.
ERIC Educational Resources Information Center
Eppler, Thomas
This document is a curriculum guide for a 180-hour course in advanced electronics for 11th and 12th grades that has four instructional units. The instructional units are orientation, discrete components, integrated circuits, and electronic systems. The document includes a course flow chart; a two-page section that describes the course, lists…
Dissociative electron attachment studies on acetone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prabhudesai, Vaibhav S., E-mail: vaibhav@tifr.res.in; Tadsare, Vishvesh; Ghosh, Sanat
Dissociative electron attachment (DEA) to acetone is studied in terms of the absolute cross section for various fragment channels in the electron energy range of 0–20 eV. H{sup −} is found to be the most dominant fragment followed by O{sup −} and OH{sup −} with only one resonance peak between 8 and 9 eV. The DEA dynamics is studied by measuring the angular distribution and kinetic energy distribution of fragment anions using Velocity Slice Imaging technique. The kinetic energy and angular distribution of H{sup −} and O{sup −} fragments suggest a many body break-up for the lone resonance observed. Themore » ab initio calculations show that electron is captured in the multi-centered anti-bonding molecular orbital which would lead to a many body break-up of the resonance.« less
Papachristou, Georgios I; Machicado, Jorge D; Stevens, Tyler; Goenka, Mahesh Kumar; Ferreira, Miguel; Gutierrez, Silvia C; Singh, Vikesh K; Kamal, Ayesha; Gonzalez-Gonzalez, Jose A; Pelaez-Luna, Mario; Gulla, Aiste; Zarnescu, Narcis O; Triantafyllou, Konstantinos; Barbu, Sorin T; Easler, Jeffrey; Ocampo, Carlos; Capurso, Gabriele; Archibugi, Livia; Cote, Gregory A; Lambiase, Louis; Kochhar, Rakesh; Chua, Tiffany; Tiwari, Subhash Ch; Nawaz, Haq; Park, Walter G; de-Madaria, Enrique; Lee, Peter J; Wu, Bechien U; Greer, Phil J; Dugum, Mohannad; Koutroumpakis, Efstratios; Akshintala, Venkata; Gougol, Amir
2017-01-01
We have established a multicenter international consortium to better understand the natural history of acute pancreatitis (AP) worldwide and to develop a platform for future randomized clinical trials. The AP patient registry to examine novel therapies in clinical experience (APPRENTICE) was formed in July 2014. Detailed web-based questionnaires were then developed to prospectively capture information on demographics, etiology, pancreatitis history, comorbidities, risk factors, severity biomarkers, severity indices, health-care utilization, management strategies, and outcomes of AP patients. Between November 2015 and September 2016, a total of 20 sites (8 in the United States, 5 in Europe, 3 in South America, 2 in Mexico and 2 in India) prospectively enrolled 509 AP patients. All data were entered into the REDCap (Research Electronic Data Capture) database by participating centers and systematically reviewed by the coordinating site (University of Pittsburgh). The approaches and methodology are described in detail, along with an interim report on the demographic results. APPRENTICE, an international collaboration of tertiary AP centers throughout the world, has demonstrated the feasibility of building a large, prospective, multicenter patient registry to study AP. Analysis of the collected data may provide a greater understanding of AP and APPRENTICE will serve as a future platform for randomized clinical trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Yongjun; Lim, Jonghyuck; Kim, Namkug
2013-05-15
Purpose: To investigate the effect of using different computed tomography (CT) scanners on the accuracy of high-resolution CT (HRCT) images in classifying regional disease patterns in patients with diffuse lung disease, support vector machine (SVM) and Bayesian classifiers were applied to multicenter data. Methods: Two experienced radiologists marked sets of 600 rectangular 20 Multiplication-Sign 20 pixel regions of interest (ROIs) on HRCT images obtained from two scanners (GE and Siemens), including 100 ROIs for each of local patterns of lungs-normal lung and five of regional pulmonary disease patterns (ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). Each ROI was assessedmore » using 22 quantitative features belonging to one of the following descriptors: histogram, gradient, run-length, gray level co-occurrence matrix, low-attenuation area cluster, and top-hat transform. For automatic classification, a Bayesian classifier and a SVM classifier were compared under three different conditions. First, classification accuracies were estimated using data from each scanner. Next, data from the GE and Siemens scanners were used for training and testing, respectively, and vice versa. Finally, all ROI data were integrated regardless of the scanner type and were then trained and tested together. All experiments were performed based on forward feature selection and fivefold cross-validation with 20 repetitions. Results: For each scanner, better classification accuracies were achieved with the SVM classifier than the Bayesian classifier (92% and 82%, respectively, for the GE scanner; and 92% and 86%, respectively, for the Siemens scanner). The classification accuracies were 82%/72% for training with GE data and testing with Siemens data, and 79%/72% for the reverse. The use of training and test data obtained from the HRCT images of different scanners lowered the classification accuracy compared to the use of HRCT images from the same scanner. For integrated ROI data obtained from both scanners, the classification accuracies with the SVM and Bayesian classifiers were 92% and 77%, respectively. The selected features resulting from the classification process differed by scanner, with more features included for the classification of the integrated HRCT data than for the classification of the HRCT data from each scanner. For the integrated data, consisting of HRCT images of both scanners, the classification accuracy based on the SVM was statistically similar to the accuracy of the data obtained from each scanner. However, the classification accuracy of the integrated data using the Bayesian classifier was significantly lower than the classification accuracy of the ROI data of each scanner. Conclusions: The use of an integrated dataset along with a SVM classifier rather than a Bayesian classifier has benefits in terms of the classification accuracy of HRCT images acquired with more than one scanner. This finding is of relevance in studies involving large number of images, as is the case in a multicenter trial with different scanners.« less
Microfluidic stretchable RF electronics.
Cheng, Shi; Wu, Zhigang
2010-12-07
Stretchable electronics is a revolutionary technology that will potentially create a world of radically different electronic devices and systems that open up an entirely new spectrum of possibilities. This article proposes a microfluidic based solution for stretchable radio frequency (RF) electronics, using hybrid integration of active circuits assembled on flex foils and liquid alloy passive structures embedded in elastic substrates, e.g. polydimethylsiloxane (PDMS). This concept was employed to implement a 900 MHz stretchable RF radiation sensor, consisting of a large area elastic antenna and a cluster of conventional rigid components for RF power detection. The integrated radiation sensor except the power supply was fully embedded in a thin elastomeric substrate. Good electrical performance of the standalone stretchable antenna as well as the RF power detection sub-module was verified by experiments. The sensor successfully detected the RF radiation over 5 m distance in the system demonstration. Experiments on two-dimensional (2D) stretching up to 15%, folding and twisting of the demonstrated sensor were also carried out. Despite the integrated device was severely deformed, no failure in RF radiation sensing was observed in the tests. This technique illuminates a promising route of realizing stretchable and foldable large area integrated RF electronics that are of great interest to a variety of applications like wearable computing, health monitoring, medical diagnostics, and curvilinear electronics.
High temperature electronic excitation and ionization rates in gases
NASA Technical Reports Server (NTRS)
Hansen, Frederick
1991-01-01
The relaxation times for electronic excitation due to electron bombardment of atoms was found to be quite short, so that electron kinetic temperature (T sub e) and the electron excitation temperature (T asterisk) should equilibrate quickly whenever electrons are present. However, once equilibrium has been achieved, further energy to the excited electronic states and to the kinetic energy of free electrons must be fed in by collisions with heavy particles that cause vibrational and electronic state transitions. The rate coefficients for excitation of electronic states produced by heavy particle collision have not been well known. However, a relatively simple semi-classical theory has been developed here which is analytic up to the final integration over a Boltzmann distribution of collision energies; this integral can then be evaluated numerically by quadrature. Once the rate coefficients have been determined, the relaxation of electronic excitation energy can be evaluated and compared with the relaxation rates of vibrational excitation. Then the relative importance of these two factors, electronic excitation and vibrational excitation by heavy particle collision, on the transfer of energy to free electron motion, can be assessed.
NASA Astrophysics Data System (ADS)
Zhang, Jianguo; Chen, Xiaomeng; Zhuang, Jun; Jiang, Jianrong; Zhang, Xiaoyan; Wu, Dongqing; Huang, H. K.
2003-05-01
In this paper, we presented a new security approach to provide security measures and features in both healthcare information systems (PACS, RIS/HIS), and electronic patient record (EPR). We introduced two security components, certificate authoring (CA) system and patient record digital signature management (DSPR) system, as well as electronic envelope technology, into the current hospital healthcare information infrastructure to provide security measures and functions such as confidential or privacy, authenticity, integrity, reliability, non-repudiation, and authentication for in-house healthcare information systems daily operating, and EPR exchanging among the hospitals or healthcare administration levels, and the DSPR component manages the all the digital signatures of patient medical records signed through using an-symmetry key encryption technologies. The electronic envelopes used for EPR exchanging are created based on the information of signers, digital signatures, and identifications of patient records stored in CAS and DSMS, as well as the destinations and the remote users. The CAS and DSMS were developed and integrated into a RIS-integrated PACS, and the integration of these new security components is seamless and painless. The electronic envelopes designed for EPR were used successfully in multimedia data transmission.
Modeling of anomalous electron mobility in Hall thrusters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koo, Justin W.; Boyd, Iain D.
Accurate modeling of the anomalous electron mobility is absolutely critical for successful simulation of Hall thrusters. In this work, existing computational models for the anomalous electron mobility are used to simulate the UM/AFRL P5 Hall thruster (a 5 kW laboratory model) in a two-dimensional axisymmetric hybrid particle-in-cell Monte Carlo collision code. Comparison to experimental results indicates that, while these computational models can be tuned to reproduce the correct thrust or discharge current, it is very difficult to match all integrated performance parameters (thrust, power, discharge current, etc.) simultaneously. Furthermore, multiple configurations of these computational models can produce reasonable integrated performancemore » parameters. A semiempirical electron mobility profile is constructed from a combination of internal experimental data and modeling assumptions. This semiempirical electron mobility profile is used in the code and results in more accurate simulation of both the integrated performance parameters and the mean potential profile of the thruster. Results indicate that the anomalous electron mobility, while absolutely necessary in the near-field region, provides a substantially smaller contribution to the total electron mobility in the high Hall current region near the thruster exit plane.« less
Wolk, D. M.; Struelens, M. J.; Pancholi, P.; Davis, T.; Della-Latta, P.; Fuller, D.; Picton, E.; Dickenson, R.; Denis, O.; Johnson, D.; Chapin, K.
2009-01-01
A multicenter preclinical evaluation was conducted to evaluate the performance of two Cepheid Xpert assays for detection of methicillin-resistant Staphylococcus aureus (MRSA) and S. aureus. Sensitivity was 97.1% and 98.3% for MRSA in wound and blood culture specimens, respectively. Sensitivity was 100% for S. aureus from both specimen types. PMID:19144803
Integrating knowledge based functionality in commercial hospital information systems.
Müller, M L; Ganslandt, T; Eich, H P; Lang, K; Ohmann, C; Prokosch, H U
2000-01-01
Successful integration of knowledge-based functions in the electronic patient record depends on direct and context-sensitive accessibility and availability to clinicians and must suit their workflow. In this paper we describe an exemplary integration of an existing standalone scoring system for acute abdominal pain into two different commercial hospital information systems using Java/Corba technolgy.
A method to obtain static potential for electron-molecule scattering
NASA Astrophysics Data System (ADS)
Srivastava, Rajesh; Das, Tapasi; Stauffer, Allan
2014-05-01
Electron scattering from molecules is complicated by the fact that molecules are a multi-centered target with the nuclei of the constituent atoms being a center of charge. One of the most important parts of a scattering calculation is to obtain the static potential which represents the interaction of the incident electron with the unperturbed charge distribution of the molecule. A common way to represent the charge distribution of molecules is with Gaussian orbitals centered on the various nuclei. We have derived a way to calculate spherically-averaged molecular static potentials using this form of molecular wave function which is mostly analytic. This method has been applied to elastic electron scattering from water molecules and we obtained differential cross sections which are compared with previous experimental and theoretical results. The method can be extended to more complex molecules. One of us (RS) is thankful to IAEA, Vienna, Austria and DAE-BRNS, Mumbai, India for financial support.
Coplanar semiconductor-metal circuitry defined on few-layer MoTe2 via polymorphic heteroepitaxy
NASA Astrophysics Data System (ADS)
Sung, Ji Ho; Heo, Hoseok; Si, Saerom; Kim, Yong Hyeon; Noh, Hyeong Rae; Song, Kyung; Kim, Juho; Lee, Chang-Soo; Seo, Seung-Young; Kim, Dong-Hwi; Kim, Hyoung Kug; Yeom, Han Woong; Kim, Tae-Hwan; Choi, Si-Young; Kim, Jun Sung; Jo, Moon-Ho
2017-11-01
Crystal polymorphism selectively stabilizes the electronic phase of atomically thin transition-metal dichalcogenides (TMDCs) as metallic or semiconducting, suggesting the potential to integrate these polymorphs as circuit components in two-dimensional electronic circuitry. Developing a selective and sequential growth strategy for such two-dimensional polymorphs in the vapour phase is a critical step in this endeavour. Here, we report on the polymorphic integration of distinct metallic (1T‧) and semiconducting (2H) MoTe2 crystals within the same atomic planes by heteroepitaxy. The realized polymorphic coplanar contact is atomically coherent, and its barrier potential is spatially tight-confined over a length of only a few nanometres, with a lowest contact barrier height of ∼25 meV. We also demonstrate the generality of our synthetic integration approach for other TMDC polymorph films with large areas.
Physics of Nonmagnetic Relativistic Thermal Plasmas. Ph.D. Thesis - Calif. Univ., San Diego
NASA Technical Reports Server (NTRS)
Dermer, C. D.
1984-01-01
A detailed treatment of the kinematics of relativistic systems of particles and photons is presented. In the case of a relativistic Maxwell-Boltzmann distribution of particles, the reaction rate and luminosity are written as single integrals over the invariant cross section, and the production spectrum is written as a double integral over the cross section differential in the energy of the produced particles (or photons) in the center-of-momentum system of two colliding particles. The results are applied to the calculation of the annihilation spectrum of a thermal electron-positron plasma, confirming previous numerical and analytic results. Relativistic thermal electron-ion and electron-electron bremsstrahlung are calculated exactly to lowest order, and relativistic thermal electron-positron bremsstrahlung is calculated in an approximate fashion. An approximate treatment of relativistic Comptonization is developed. The question of thermalization of a relativistic plasma is considered. A formula for the energy loss or exchange rate from the interaction of two relativistic Maxwell-Boltzmann plasmas at different temperatures is derived. Application to a stable, uniform, nonmagnetic relativistic thermal plasma is made. Comparison is made with other studies.
Patterned arrays of lateral heterojunctions within monolayer two-dimensional semiconductors
Mahjouri-Samani, Masoud; Lin, Ming-Wei; Wang, Kai; ...
2015-07-22
The formation of semiconductor heterojunctions and their high density integration are foundations of modern electronics and optoelectronics. To enable two-dimensional (2D) crystalline semiconductors as building blocks in next generation electronics, developing methods to deterministically form lateral heterojunctions is crucial. Here we demonstrate a process strategy for the formation of lithographically-patterned lateral semiconducting heterojunctions within a single 2D crystal. E-beam lithography is used to pattern MoSe 2 monolayer crystals with SiO 2, and the exposed locations are selectively and totally converted to MoS 2 using pulsed laser deposition (PLD) of sulfur in order to form MoSe 2/MoS 2 heterojunctions in predefinedmore » patterns. The junctions and conversion process are characterized by atomically resolved scanning transmission electron microscopy, photoluminescence, and Raman spectroscopy. This demonstration of lateral semiconductor heterojunction arrays within a single 2D crystal is an essential step for the lateral integration of 2D semiconductor building blocks with different electronic and optoelectronic properties for high-density, ultrathin circuitry.« less
Data base systems in electronic design engineering
NASA Technical Reports Server (NTRS)
Williams, D.
1980-01-01
The concepts of an integrated design data base system (DBMS) as it might apply to an electronic design company are discussed. Data elements of documentation, project specifications, project tracking, firmware, software, electronic and mechanical design can be integrated and managed through a single DBMS. Combining the attributes of a DBMS data handler with specialized systems and functional data can provide users with maximum flexibility, reduced redundancy, and increased overall systems performance. Although some system overhead is lost due to redundancy in transitory data, it is believed the combination of the two data types is advisable rather than trying to do all data handling through a single DBMS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volkov, S. A., E-mail: volkoff-sergey@mail.ru
2016-06-15
A new subtractive procedure for canceling ultraviolet and infrared divergences in the Feynman integrals described here is developed for calculating QED corrections to the electron anomalous magnetic moment. The procedure formulated in the form of a forest expression with linear operators applied to Feynman amplitudes of UV-diverging subgraphs makes it possible to represent the contribution of each Feynman graph containing only electron and photon propagators in the form of a converging integral with respect to Feynman parameters. The application of the developed method for numerical calculation of two- and threeloop contributions is described.
Chen, Jingyi; Lin, Yazhu; Yan, Jie; Wu, Yong; Hu, Rong
2018-04-01
Terminal illness not only causes physical suffering but also spiritual distress. Spiritual care has been widely implemented by healthcare professionals to assist patients coping with spiritual distress. However, the effects of spiritual care need to be clear. To evaluate the effects of spiritual care on quality of life and spiritual well-being among patients with terminal illness. Systematic review according to the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidance. A comprehensive search was conducted in nine electronic databases from date of inception to May 2017. Hand searches of the bibliographies of relevant articles were also performed. The studies were independently reviewed by two investigators who scored them for methodological quality using the Cochrane Risk of Bias Tool. No statistical pooling of outcomes was performed and a narrative summary was chosen to describe the included studies. A total of 19 studies with 1548 participants were identified in the systematic review, corresponding to seven kinds of interventions. The risk of bias for these studies were all rated as moderate. A majority of studies indicated that spiritual care had a potential beneficial effect on quality of life and spiritual well-being among patients with terminal illness. It is suggested that healthcare professionals integrate spiritual care with usual care in palliative care. When providing spiritual care, healthcare professionals should take into consideration patients' spiritual needs, preference, and cultural background. More multicenter and disciplinary studies with rigorous designs are needed in the future.
NASA Astrophysics Data System (ADS)
Rathore, Saima; Bakas, Spyridon; Akbari, Hamed; Shukla, Gaurav; Rozycki, Martin; Davatzikos, Christos
2018-02-01
There is mounting evidence that assessment of multi-parametric magnetic resonance imaging (mpMRI) profiles can noninvasively predict survival in many cancers, including glioblastoma. The clinical adoption of mpMRI as a prognostic biomarker, however, depends on its applicability in a multicenter setting, which is hampered by inter-scanner variations. This concept has not been addressed in existing studies. We developed a comprehensive set of within-patient normalized tumor features such as intensity profile, shape, volume, and tumor location, extracted from multicenter mpMRI of two large (npatients=353) cohorts, comprising the Hospital of the University of Pennsylvania (HUP, npatients=252, nscanners=3) and The Cancer Imaging Archive (TCIA, npatients=101, nscanners=8). Inter-scanner harmonization was conducted by normalizing the tumor intensity profile, with that of the contralateral healthy tissue. The extracted features were integrated by support vector machines to derive survival predictors. The predictors' generalizability was evaluated within each cohort, by two cross-validation configurations: i) pooled/scanner-agnostic, and ii) across scanners (training in multiple scanners and testing in one). The median survival in each configuration was used as a cut-off to divide patients in long- and short-survivors. Accuracy (ACC) for predicting long- versus short-survivors, for these configurations was ACCpooled=79.06% and ACCpooled=84.7%, ACCacross=73.55% and ACCacross=74.76%, in HUP and TCIA datasets, respectively. The hazard ratio at 95% confidence interval was 3.87 (2.87-5.20, P<0.001) and 6.65 (3.57-12.36, P<0.001) for HUP and TCIA datasets, respectively. Our findings suggest that adequate data normalization coupled with machine learning classification allows robust prediction of survival estimates on mpMRI acquired by multiple scanners.
NASA Technical Reports Server (NTRS)
Bryant, W. H.; Morrell, F. R.
1981-01-01
Attention is given to a redundant strapdown inertial measurement unit for integrated avionics. The system consists of four two-degree-of-freedom turned rotor gyros and four two-degree-of-freedom accelerometers in a skewed and separable semi-octahedral array. The unit is coupled through instrument electronics to two flight computers which compensate sensor errors. The flight computers are interfaced to the microprocessors and process failure detection, isolation, redundancy management and flight control/navigation algorithms. The unit provides dual fail-operational performance and has data processing frequencies consistent with integrated avionics concepts presently planned.
Particle-in-a-box model of one-dimensional excitons in conjugated polymers
NASA Astrophysics Data System (ADS)
Pedersen, Thomas G.; Johansen, Per M.; Pedersen, Henrik C.
2000-04-01
A simple two-particle model of excitons in conjugated polymers is proposed as an alternative to usual highly computationally demanding quantum chemical methods. In the two-particle model, the exciton is described as an electron-hole pair interacting via Coulomb forces and confined to the polymer backbone by rigid walls. Furthermore, by integrating out the transverse part, the two-particle equation is reduced to one-dimensional form. It is demonstrated how essentially exact solutions are obtained in the cases of short and long conjugation length, respectively. From a linear combination of these cases an approximate solution for the general case is obtained. As an application of the model the influence of a static electric field on the electron-hole overlap integral and exciton energy is considered.
Helmy, Samir; Marschalek, Julian; Bader, Yvonne; Koch, Marianne; Schmidt, Alice; Kanzler, Marina; Gyoeri, Georg; Polterauer, Stephan; Reinthaller, Alexander; Grimm, Christoph
2016-06-01
Transplantation results in a 5-time elevated risk for a variety of malignancies (Kaposi sarcoma, skin, liver, lung, gastrointestinal cancer). A patient's risk for malignancies could be of particular interest for the follow-up programs of patients and risk adaption after kidney transplantation. The aim of this study was to identify independent risk factors for de novo malignancies in women after renal transplantation. This is a multicenter transversal study, conducted at the Medical University of Vienna and Hospital Rudolfstiftung, Vienna, Austria. We included female kidney graft recipients who were transplanted between 1980 and 2012 and followed-up at our institutions (N = 280). Clinical data of patients were extracted from hospital charts and electronic patient files. Patients were interviewed using a standardized questionnaire regarding their medical history, history of transplantation, and malignant diseases. Detailed information about present and past immunosuppressive regimens, rejection episodes and therapies, renal graft function, and information about primary disease was obtained. Diagnostic work-up and/or surgical exploration was performed if any presence of malignancy was suspected during routine follow-up. Histological specimens were obtained from all patients. the presence of de novo malignancy after kidney transplantation. Two hundred sixty-two women were included for statistical analysis. Median (interquartile range) follow-up period after transplantation was 101.1 (27.3-190.7) months. Thirty-two patients (12.2%) developed a malignancy: dermatologic malignancies (5.7%), breast cancer (3.4%), cervical cancer (0.8%), lung cancer (0.4%), gastrointestinal malignancies (1.5%), vulvar cancer (0.4%), and unclassified malignancies (1.9%). Median (interquartile range) time to malignancy after transplantation was 185.9 (92.0-257.6) months. Cumulative cancer rates were 4.9% (1 year), 14.4% (3 years), 16.4% (5 years), and 21.8% (10 years). Second transplantations were identified as independent risk factor for development of malignancy after transplantation. Long-term risk of developing a malignancy after kidney transplantation is high, which might justify a follow-up of more than 10 years.
Explicitly-correlated Gaussian geminals in electronic structure calculations
NASA Astrophysics Data System (ADS)
Szalewicz, Krzysztof; Jeziorski, Bogumił
2010-11-01
Explicitly correlated functions have been used since 1929, but initially only for two-electron systems. In 1960, Boys and Singer showed that if the correlating factor is of Gaussian form, many-electron integrals can be computed for general molecules. The capability of explicitly correlated Gaussian (ECG) functions to accurately describe many-electron atoms and molecules was demonstrated only in the early 1980s when Monkhorst, Zabolitzky and the present authors cast the many-body perturbation theory (MBPT) and coupled cluster (CC) equations as a system of integro-differential equations and developed techniques of solving these equations with two-electron ECG functions (Gaussian-type geminals, GTG). This work brought a new accuracy standard to MBPT/CC calculations. In 1985, Kutzelnigg suggested that the linear r 12 correlating factor can also be employed if n-electron integrals, n > 2, are factorised with the resolution of identity. Later, this factor was replaced by more general functions f (r 12), most often by ? , usually represented as linear combinations of Gaussian functions which makes the resulting approach (called F12) a special case of the original GTG expansion. The current state-of-art is that, for few-electron molecules, ECGs provide more accurate results than any other basis available, but for larger systems the F12 approach is the method of choice, giving significant improvements over orbital calculations.
Papachristou, Georgios I.; Machicado, Jorge D.; Stevens, Tyler; Goenka, Mahesh Kumar; Ferreira, Miguel; Gutierrez, Silvia C.; Singh, Vikesh K.; Kamal, Ayesha; Gonzalez-Gonzalez, Jose A.; Pelaez-Luna, Mario; Gulla, Aiste; Zarnescu, Narcis O.; Triantafyllou, Konstantinos; Barbu, Sorin T.; Easler, Jeffrey; Ocampo, Carlos; Capurso, Gabriele; Archibugi, Livia; Cote, Gregory A.; Lambiase, Louis; Kochhar, Rakesh; Chua, Tiffany; Tiwari, Subhash Ch.; Nawaz, Haq; Park, Walter G.; de-Madaria, Enrique; Lee, Peter J.; Wu, Bechien U.; Greer, Phil J.; Dugum, Mohannad; Koutroumpakis, Efstratios; Akshintala, Venkata; Gougol, Amir
2017-01-01
Background We have established a multicenter international consortium to better understand the natural history of acute pancreatitis (AP) worldwide and to develop a platform for future randomized clinical trials. Methods The AP patient registry to examine novel therapies in clinical experience (APPRENTICE) was formed in July 2014. Detailed web-based questionnaires were then developed to prospectively capture information on demographics, etiology, pancreatitis history, comorbidities, risk factors, severity biomarkers, severity indices, health-care utilization, management strategies, and outcomes of AP patients. Results Between November 2015 and September 2016, a total of 20 sites (8 in the United States, 5 in Europe, 3 in South America, 2 in Mexico and 2 in India) prospectively enrolled 509 AP patients. All data were entered into the REDCap (Research Electronic Data Capture) database by participating centers and systematically reviewed by the coordinating site (University of Pittsburgh). The approaches and methodology are described in detail, along with an interim report on the demographic results. Conclusion APPRENTICE, an international collaboration of tertiary AP centers throughout the world, has demonstrated the feasibility of building a large, prospective, multicenter patient registry to study AP. Analysis of the collected data may provide a greater understanding of AP and APPRENTICE will serve as a future platform for randomized clinical trials. PMID:28042246
Integrated digital inverters based on two-dimensional anisotropic ReS₂ field-effect transistors
Liu, Erfu; Fu, Yajun; Wang, Yaojia; ...
2015-05-07
Semiconducting two-dimensional transition metal dichalcogenides are emerging as top candidates for post-silicon electronics. While most of them exhibit isotropic behaviour, lowering the lattice symmetry could induce anisotropic properties, which are both scientifically interesting and potentially useful. Here we present atomically thin rhenium disulfide (ReS₂) flakes with unique distorted 1T structure, which exhibit in-plane anisotropic properties. We fabricated monolayer and few-layer ReS₂ field-effect transistors, which exhibit competitive performance with large current on/off ratios (~10⁷) and low subthreshold swings (100 mV per decade). The observed anisotropic ratio along two principle axes reaches 3.1, which is the highest among all known two-dimensional semiconductingmore » materials. Furthermore, we successfully demonstrated an integrated digital inverter with good performance by utilizing two ReS₂ anisotropic field-effect transistors, suggesting the promising implementation of large-scale two-dimensional logic circuits. Our results underscore the unique properties of two-dimensional semiconducting materials with low crystal symmetry for future electronic applications.« less
NASA Astrophysics Data System (ADS)
Havu, Vile; Blum, Volker; Scheffler, Matthias
2007-03-01
Numeric atom-centered local orbitals (NAO) are efficient basis sets for all-electron electronic structure theory. The locality of NAO's can be exploited to render (in principle) all operations of the self-consistency cycle O(N). This is straightforward for 3D integrals using domain decomposition into spatially close subsets of integration points, enabling critical computational savings that are effective from ˜tens of atoms (no significant overhead for smaller systems) and make large systems (100s of atoms) computationally feasible. Using a new all-electron NAO-based code,^1 we investigate the quantitative impact of exploiting this locality on two distinct classes of systems: Large light-element molecules [Alanine-based polypeptide chains (Ala)n], and compact transition metal clusters. Strict NAO locality is achieved by imposing a cutoff potential with an onset radius rc, and exploited by appropriately shaped integration domains (subsets of integration points). Conventional tight rc<= 3å have no measurable accuracy impact in (Ala)n, but introduce inaccuracies of 20-30 meV/atom in Cun. The domain shape impacts the computational effort by only 10-20 % for reasonable rc. ^1 V. Blum, R. Gehrke, P. Havu, V. Havu, M. Scheffler, The FHI Ab Initio Molecular Simulations (aims) Project, Fritz-Haber-Institut, Berlin (2006).
ERIC Educational Resources Information Center
Hung, Wei-Chen; Chao, Chia-An
2007-01-01
This study has reviewed major design approaches for electronic performance support systems and identified two common problems: users' inability to comprehend screen-based material and poorly designed instructional scaffolds. This paper presents a design approach, called the "Matrix-Aided Performance System" ("MAPS"), which enables these problems…
TERMTrial--terminology-based documentation systems for cooperative clinical trials.
Merzweiler, A; Weber, R; Garde, S; Haux, R; Knaup-Gregori, P
2005-04-01
Within cooperative groups of multi-center clinical trials a standardized documentation is a prerequisite for communication and sharing of data. Standardizing documentation systems means standardizing the underlying terminology. The management and consistent application of terminology systems is a difficult and fault-prone task, which should be supported by appropriate software tools. Today, documentation systems for clinical trials are often implemented as so-called Remote-Data-Entry-Systems (RDE-systems). Although there are many commercial systems, which support the development of RDE-systems there is none offering a comprehensive terminological support. Therefore, we developed the software system TERMTrial which consists of a component for the definition and management of terminology systems for cooperative groups of clinical trials and two components for the terminology-based automatic generation of trial databases and terminology-based interactive design of electronic case report forms (eCRFs). TERMTrial combines the advantages of remote data entry with a comprehensive terminological control.
2012-01-01
Background To establish a common database on particle therapy for the evaluation of clinical studies integrating a large variety of voluminous datasets, different documentation styles, and various information systems, especially in the field of radiation oncology. Methods We developed a web-based documentation system for transnational and multicenter clinical studies in particle therapy. 560 patients have been treated from November 2009 to September 2011. Protons, carbon ions or a combination of both, as well as a combination with photons were applied. To date, 12 studies have been initiated and more are in preparation. Results It is possible to immediately access all patient information and exchange, store, process, and visualize text data, any DICOM images and multimedia data. Accessing the system and submitting clinical data is possible for internal and external users. Integrated into the hospital environment, data is imported both manually and automatically. Security and privacy protection as well as data validation and verification are ensured. Studies can be designed to fit individual needs. Conclusions The described database provides a basis for documentation of large patient groups with specific and specialized questions to be answered. Having recently begun electronic documentation, it has become apparent that the benefits lie in the user-friendly and timely workflow for documentation. The ultimate goal is a simplification of research work, better study analyses quality and eventually, the improvement of treatment concepts by evaluating the effectiveness of particle therapy. PMID:22828013
Feinstein, Matthew J.; Nance, Robin M.; Drozd, Daniel R.; Ning, Hongyan; Delaney, Joseph A.; Heckbert, Susan R.; Budoff, Matthew J.; Mathews, William C.; Kitahata, Mari M.; Saag, Michael S.; Eron, Joseph J.; Moore, Richard D.; Achenbach, Chad J.; Lloyd-Jones, Donald M.; Crane, Heidi M.
2017-01-01
Importance Persons with human immunodeficiency virus (HIV) treated with antiretroviral therapy (ART) have improved longevity but are at elevated risk for myocardial infarction (MI) due to common MI risk factors and HIV-specific factors. Despite these elevated MI rates, optimal methods to predict MI risks for HIV-infected persons remain unclear. Objective To determine the extent to which existing and de novo estimation tools predict MI in a multi-center HIV cohort with rigorous MI adjudication. Design We evaluated the performance of standard-of-care and two new data-derived MI risk estimation models in the Centers for AIDS Research Network of Integrated Clinical Systems (CNICS) multi-center prospective clinical cohort. The new risk estimation models were validated in a cohort separate from the derivation cohort. Setting Clinical sites across the U.S. where HIV-infected adults receive medical care in inpatient and outpatient settings. Participants HIV-infected adults receiving care anytime since 1995 at 5 CNICS sites where MIs were adjudicated (N=19829). Exposures Common cardiovascular risk factors, HIV viral load, CD4 count, and medication use were used to calculate predicted event rates. Main Outcome and Measures Observed MI rates over the course of follow-up, scaled to 10 years using an observed prime approach to account for dropout and loss to follow-up prior to 10 years. Results MI rates were higher among blacks, older participants, and participants who were not virally suppressed. The 2013 Pooled Cohort Equations (PCEs), which predict composite rates of MI and stroke, adequately discriminated MI risk (Harrell’s C Statistic = 0.75). Two data-derived models incorporating HIV-specific covariates exhibited weak calibration in a validation sample and did not discriminate risk any better (Harrell’s C Statistic = 0.72 and 0.73) than the PCEs. The PCEs were moderately calibrated in CNICS but predicted consistently lower than observed prime rates of MI. The PCEs Conclusions and relevance The PCEs discriminated MI risk and were moderately calibrated in this multi-center HIV cohort. Adding HIV-specific factors did not improve model performance. As HIV-infected cohorts capture and assess outcomes of MI and stroke, the performance of risk estimation tools should be revisited. PMID:28002550
A parameter study of the two-fluid solar wind
NASA Technical Reports Server (NTRS)
Sandbaek, Ornulf; Leer, Egil; Holzer, Thomas E.
1992-01-01
A two-fluid model of the solar wind was introduced by Sturrock and Hartle (1966) and Hartle and Sturrock (1968). In these studies the proton energy equation was integrated neglecting the heat conductive term. Later several authors solved the equations for the two-fluid solar wind model keeping the proton heat conductive term. Methods where the equations are integrated simultaneously outward and inward from the critical point were used. The equations were also integrated inward from a large heliocentric distance. These methods have been applied to cases with low coronal base electron densities and high base temperatures. In this paper we present a method of integrating the two-fluid solar wind equations using an iteration procedure where the equations are integrated separately and the proton flux is kept constant during the integrations. The technique is applicable for a wide range of coronal base densities and temperatures. The method is used to carry out a parameter study of the two-fluid solar wind.
Kim, George P; Mahoney, Michelle R; Szydlo, Daniel; Mok, Tony S K; Marshke, Robert; Holen, Kyle; Picus, Joel; Boyer, Michael; Pitot, Henry C; Rubin, Joseph; Philip, Philip A; Nowak, Anna; Wright, John J; Erlichman, Charles
2012-02-01
Bortezomib (PS-341, VELCADE®) is a selective inhibitor of the 26S proteasome, an integral component of the ubiquitin-proteasome pathway. This phase II study evaluated the activity and tolerability of bortezomib in unresectable hepatocellular carcinoma (HCC) patients. The primary endpoint was confirmed tumor response rate (RR) with secondary endpoints including duration of response, time to disease progression, survival and toxicity. Treatment consisted of bortezomib, 1.3 mg/m2 IV bolus on days 1, 4, 8, and 11 of each 21-day treatment cycle. Eligibility included: no prior systemic chemotherapy, ECOG PS 0-2, Child-Pugh A or B, preserved hematologic, hepatic and neurologic function; prior liver-directed therapy was permitted. Thirty-five patients enrolled and received a median of 2 cycles of treatment (range 1-12). Overall, 24 and 4 patients had a maximum severity of grade 3 and 4 adverse events (AEs), respectively. No treatment related deaths occurred. Only thrombocytopenia (11%) was seen in greater than 10% of patients. One patient achieved a partial response, lasting 13 weeks during treatment and progressed 11.6 months later; two patients received treatment for greater than 6 months. Median time-to-progression was 1.6 months and median survival was 6.0 months. This international, multicenter trial evaluated bortezomib as monotherapy in unresectable HCC patients. And, despite the lack of significant activity, this report serves as a baseline clinical experience for the development of future dual biologic approaches including bortezomib.
An international, multicenter phase II trial of bortezomib in patients with hepatocellular carcinoma
Kim, George P.; Mahoney, Michelle R.; Szydlo, Daniel; Mok, Tony S. K.; Marshke, Robert; Holen, Kyle; Picus, Joel; Boyer, Michael; Pitot, Henry C.; Rubin, Joseph; Philip, Philip A.; Nowak, Anna; Wright, John J.; Erlichman, Charles
2013-01-01
Summary Background and Rationale Bortezomib (PS-341, VELCADE®) is a selective inhibitor of the 26S proteasome, an integral component of the ubiquitinproteasome pathway. This phase II study evaluated the activity and tolerability of bortezomib in unresectable hepatocellular carcinoma (HCC) patients. Methods The primary endpoint was confirmed tumor response rate (RR) with secondary endpoints including duration of response, time to disease progression, survival and toxicity. Treatment consisted of bortezomib, 1.3 mg/m2 IV bolus on days 1, 4, 8, and 11 of each 21-day treatment cycle. Eligibility included: no prior systemic chemotherapy, ECOG PS 0-2, Child-Pugh A or B, preserved hematologic, hepatic and neurologic function; prior liver-directed therapy was permitted. Results Thirty-five patients enrolled and received a median of 2 cycles of treatment (range 1–12). Overall, 24 and 4 patients had a maximum severity of grade 3 and 4 adverse events (AEs), respectively. No treatment related deaths occurred. Only thrombocytopenia (11%) was seen in greater than 10% of patients. One patient achieved a partial response, lasting 13 weeks during treatment and progressed 11.6 months later; two patients received treatment for greater than 6 months. Median time-to-progression was 1.6 months and median survival was 6.0 months. Conclusions This international, multicenter trial evaluated bortezomib as monotherapy in unresectable HCC patients. And, despite the lack of significant activity, this report serves as a baseline clinical experience for the development of future dual biologic approaches including bortezomib. PMID:20839030
Shah, Seema; Singh, Kavita; Ali, Mohammed K.; Mohan, V.; Kadir, Muhammad Masood; Unnikrishnan, A.G.; Sahay, Rakesh Kumar; Varthakavi, Premlata; Dharmalingam, Mala; Viswanathan, Vijay; Masood, Qamar; Bantwal, Ganapathi; Khadgawat, Rajesh; Desai, Ankush; Sethi, Bipin Kumar; Shivashankar, Roopa; Ajay, Vamadevan S; Reddy, K. Srinath; Narayan, K.M. Venkat; Prabhakaran, Dorairaj; Tandon, Nikhil
2012-01-01
Aims Cardiovascular disease (CVD) is the leading cause of morbidity and mortality in people with diabetes in South Asia. The CARRS translation trial tests the effectiveness, cost-effectiveness, and sustainability of a clinic-based multi-component CVD risk reduction intervention among people with diabetes in India and Pakistan. Methods We randomly assigned 1,146 adults with diabetes recruited from 10 urban clinic sites, to receive usual care by physicians or to receive an integrated multi-component CVD risk reduction intervention. The intervention involves electronic health record management, decision-support prompts to the healthcare team, and the support of a care coordinator to actively facilitate patient and provider adherence to evidence-based guidelines. The primary outcome is a composite of multiple CVD risk factor control (blood glucose and either blood pressure or cholesterol, or all three). Other outcomes include control of the individual CVD risk factors, process and patient-centered measures, cost-effectiveness, and acceptability/feasibility. Conclusion The CARRS translation trial tests a low-cost diabetes care delivery model in urban South Asia to achieve comprehensive cardio-metabolic disease case-management of high-risk patients (clinicaltrials.gov number: NCT01212328). PMID:23084280
2005-04-01
WRAMC and all other sites in the multi-center study have been trained to use our electronic data capture system. Recent literature on Escitalopram , the...Disorder (GAD). Based on the merits of three placebo- controlled studies, Forest Laboratories announced the FDA approval of Escitalopram for the treatment...therefore there are no conclusions that can be made at this time. References: Davidson JR, Bose A, Korotzer A, Hongije Z. Escitalopram in the
2010-01-01
Oral and intravenous (IV) acetylcysteine are used for treatment of acetaminophen poisoning. The objective of this multi-center study was to compare the safety of these two routes of administration. METHODS We conducted a multi-center chart review of all patients treated with acetylcysteine for acetaminophen poisoning. The primary safety outcome was the percentage of patients with of acetylcysteine-related adverse events. RESULTS A total of 503 subjects were included in the safety analysis (306 IV only, 145 oral only and 52 both routes).There were no serious adverse events related to acetylcysteine for either route. Nausea and vomiting were the most common related adverse events and were more common with oral treatment (23% vs 9%). Anaphylactoid reactions were more common with IV administration (6% vs 2%). Conclusions Intravenous and oral acetylcysteine are both associated with minimal side effects and are safe for treatment of acetaminophen toxicity. PMID:20524832
Variability of the institutional review board process within a national research network.
Khan, Muhammad A; Barratt, Michelle S; Krugman, Scott D; Serwint, Janet R; Dumont-Driscoll, Marilyn
2014-06-01
To determine the variability of the institutional review board (IRB) process for a minimal risk multicenter study. Participants included 24 Continuity Research Network (CORNET) sites of the Academic Pediatric Association that participated in a cross-sectional study. Each site obtained individual institutional IRB approval. An anonymous questionnaire went to site investigators about the IRB process at their institution. Twenty-two of 24 sites (92%) responded. Preparation time ranged from 1 to 20 hours, mean of 7.1 hours. Individuals submitting ≤3 IRB applications/year required more time for completion than those submitting >3/year (P < .05). Thirteen of 22 (59%) study sites received approval with "exempt" status, and 6 (27%) approved as "expedited" studies. IRB experiences were highly variable across study sites. These findings indicate that multicenter research projects should anticipate barriers to timely study implementation. Improved IRB standardization or centralization for multicenter clinical studies would facilitate this type of practice-based clinical research.
NASA Astrophysics Data System (ADS)
Li, Mo; Wu, Jian; Wang, Liang-Ping; Wu, Gang; Han, Juan-Juan; Guo, Ning; Qiu, Meng-Tong
2012-12-01
Two curved crystal spectrometers are set up on the “QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several “bright spots" indicate electron temperatures between (450 eV ~ 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV ± 30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a ~ 1 MA facility.
On the exchange-hole model of London dispersion forces
NASA Astrophysics Data System (ADS)
Ángyán, János G.
2007-07-01
First-principles derivation is given for the heuristic exchange-hole model of London dispersion forces by Becke and Johnson [J. Chem. Phys. 122, 154104 (2005)]. A one-term approximation is used for the dynamic charge density response function, and it is shown that a central nonempirical ingredient of the approximate nonexpanded dispersion energy is the charge density autocorrelation function, a two-particle property, related to the exchange-correlation hole. In the framework of a dipolar approximation of the Coulomb interaction around the molecular origin, one obtains the so-called Salem-Tang-Karplus approximation to the C6 dispersion coefficient. Alternatively, by expanding the Coulomb interaction around the center of charge (centroid) of the exchange-correlation hole associated with each point in the molecular volume, a multicenter expansion is obtained around the centroids of electron localization domains, always in terms of the exchange-correlation hole. In order to get a formula analogous to that of Becke and Johnson, which involves the exchange-hole only, further assumptions are needed, related to the difficulties of obtaining the expectation value of a two-electron operator from a single determinant. Thus a connection could be established between the conventional fluctuating charge density model of London dispersion forces and the notion of the "exchange-hole dipole moment" shedding some light on the true nature of the approximations implicit in the Becke-Johnson model.
Two-photon coincident emission from thick targets for 70-keV incident electrons
NASA Astrophysics Data System (ADS)
Liu, J.; Kahler, D. L.; Quarles, C. A.
1993-04-01
Two-photon coincidence yields have been measured in thick targets of C, Al, Ag, and Ta for 70 keV incident electrons and photons radiated at +/-45° to the incident beam. A theoretical model, which is more rigorous, has been developed to simulate the two-photon processes of coherent thick-target double bremsstrahlung (TTDB) and the incoherent emission of two single-bremsstrahlung (SBSB) photons in a thick-target environment. The model is based on an integration of the thin-target cross sections over the target thickness taking into account electron energy loss, electron backscattering, and photon attenuation. It predicts a yield that is much lower than that of the previous model. The prediction of the model fits the present experimental data well by adjusting the relative weight of the two competing processes, and we find that TTDB dominates at low Z and incoherent SBSB dominates at higher Z.
Afshar, Majid; Press, Valerie G; Robison, Rachel G; Kho, Abel N; Bandi, Sindhura; Biswas, Ashvini; Avila, Pedro C; Kumar, Harsha Vardhan Madan; Yu, Byung; Naureckas, Edward T; Nyenhuis, Sharmilee M; Codispoti, Christopher D
2017-10-13
Comprehensive, rapid, and accurate identification of patients with asthma for clinical care and engagement in research efforts is needed. The original development and validation of a computable phenotype for asthma case identification occurred at a single institution in Chicago and demonstrated excellent test characteristics. However, its application in a diverse payer mix, across different health systems and multiple electronic health record vendors, and in both children and adults was not examined. The objective of this study is to externally validate the computable phenotype across diverse Chicago institutions to accurately identify pediatric and adult patients with asthma. A cohort of 900 asthma and control patients was identified from the electronic health record between January 1, 2012 and November 30, 2014. Two physicians at each site independently reviewed the patient chart to annotate cases. The inter-observer reliability between the physician reviewers had a κ-coefficient of 0.95 (95% CI 0.93-0.97). The accuracy, sensitivity, specificity, negative predictive value, and positive predictive value of the computable phenotype were all above 94% in the full cohort. The excellent positive and negative predictive values in this multi-center external validation study establish a useful tool to identify asthma cases in in the electronic health record for research and care. This computable phenotype could be used in large-scale comparative-effectiveness trials.
Stochastic evaluation of second-order many-body perturbation energies.
Willow, Soohaeng Yoo; Kim, Kwang S; Hirata, So
2012-11-28
With the aid of the Laplace transform, the canonical expression of the second-order many-body perturbation correction to an electronic energy is converted into the sum of two 13-dimensional integrals, the 12-dimensional parts of which are evaluated by Monte Carlo integration. Weight functions are identified that are analytically normalizable, are finite and non-negative everywhere, and share the same singularities as the integrands. They thus generate appropriate distributions of four-electron walkers via the Metropolis algorithm, yielding correlation energies of small molecules within a few mE(h) of the correct values after 10(8) Monte Carlo steps. This algorithm does away with the integral transformation as the hotspot of the usual algorithms, has a far superior size dependence of cost, does not suffer from the sign problem of some quantum Monte Carlo methods, and potentially easily parallelizable and extensible to other more complex electron-correlation theories.
NASA Astrophysics Data System (ADS)
Turbiner, A. V.; Escobar-Ruiz, M. A.
2013-07-01
The quantum mechanics of two Coulomb charges on a plane (e1, m1) and (e2, m2) subject to a constant magnetic field B perpendicular to the plane is considered. Four integrals of motion are explicitly indicated. It is shown that for two physically important particular cases, namely that of two particles of equal Larmor frequencies, {e_c} \\propto \\frac{e_1}{m_1}-\\frac{e_2}{m_2}=0 (e.g. two electrons) and one of a neutral system (e.g. the electron-positron pair, hydrogen atom) at rest (the center-of-mass momentum is zero) some outstanding properties occur. They are the most visible in double polar coordinates in CMS (R, ϕ) and relative (ρ, φ) coordinate systems: (i) eigenfunctions are factorizable, all factors except one with the explicit ρ-dependence are found analytically, they have definite relative angular momentum, (ii) dynamics in the ρ-direction is the same for both systems, it corresponds to a funnel-type potential and it has hidden sl(2) algebra, at some discrete values of dimensionless magnetic fields b ⩽ 1, (iii) particular integral(s) occur, (iv) the hidden sl(2) algebra emerges in finite-dimensional representation, thus, the system becomes quasi-exactly-solvable and (v) a finite number of polynomial eigenfunctions in ρ appear. Nine families of eigenfunctions are presented explicitly.
NASA Astrophysics Data System (ADS)
Bolzoni, Paolo; Somogyi, Gábor; Trócsányi, Zoltán
2011-01-01
We perform the integration of all iterated singly-unresolved subtraction terms, as defined in ref. [1], over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurent-expansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets.
Variational and robust density fitting of four-center two-electron integrals in local metrics
NASA Astrophysics Data System (ADS)
Reine, Simen; Tellgren, Erik; Krapp, Andreas; Kjærgaard, Thomas; Helgaker, Trygve; Jansik, Branislav; Høst, Stinne; Salek, Paweł
2008-09-01
Density fitting is an important method for speeding up quantum-chemical calculations. Linear-scaling developments in Hartree-Fock and density-functional theories have highlighted the need for linear-scaling density-fitting schemes. In this paper, we present a robust variational density-fitting scheme that allows for solving the fitting equations in local metrics instead of the traditional Coulomb metric, as required for linear scaling. Results of fitting four-center two-electron integrals in the overlap and the attenuated Gaussian damped Coulomb metric are presented, and we conclude that density fitting can be performed in local metrics at little loss of chemical accuracy. We further propose to use this theory in linear-scaling density-fitting developments.
Variational and robust density fitting of four-center two-electron integrals in local metrics.
Reine, Simen; Tellgren, Erik; Krapp, Andreas; Kjaergaard, Thomas; Helgaker, Trygve; Jansik, Branislav; Host, Stinne; Salek, Paweł
2008-09-14
Density fitting is an important method for speeding up quantum-chemical calculations. Linear-scaling developments in Hartree-Fock and density-functional theories have highlighted the need for linear-scaling density-fitting schemes. In this paper, we present a robust variational density-fitting scheme that allows for solving the fitting equations in local metrics instead of the traditional Coulomb metric, as required for linear scaling. Results of fitting four-center two-electron integrals in the overlap and the attenuated Gaussian damped Coulomb metric are presented, and we conclude that density fitting can be performed in local metrics at little loss of chemical accuracy. We further propose to use this theory in linear-scaling density-fitting developments.
Developing Partnerships to Create Electronic Reserves at the University of Kansas Libraries
ERIC Educational Resources Information Center
Burich, Nancy J.; Rholes, Julia
2003-01-01
Today, it is advantageous for academic libraries to look outside their own organizations to other potential campus and commercial partners when considering new services. This case study describes the planning and implementation of electronic reserves at the University of Kansas Libraries, including the integration of two commercial partners,…
Kushida, Clete A; Nichols, Deborah A; Jadrnicek, Rik; Miller, Ric; Walsh, James K; Griffin, Kara
2012-07-01
De-identification and anonymization are strategies that are used to remove patient identifiers in electronic health record data. The use of these strategies in multicenter research studies is paramount in importance, given the need to share electronic health record data across multiple environments and institutions while safeguarding patient privacy. Systematic literature search using keywords of de-identify, deidentify, de-identification, deidentification, anonymize, anonymization, data scrubbing, and text scrubbing. Search was conducted up to June 30, 2011 and involved 6 different common literature databases. A total of 1798 prospective citations were identified, and 94 full-text articles met the criteria for review and the corresponding articles were obtained. Search results were supplemented by review of 26 additional full-text articles; a total of 120 full-text articles were reviewed. A final sample of 45 articles met inclusion criteria for review and discussion. Articles were grouped into text, images, and biological sample categories. For text-based strategies, the approaches were segregated into heuristic, lexical, and pattern-based systems versus statistical learning-based systems. For images, approaches that de-identified photographic facial images and magnetic resonance image data were described. For biological samples, approaches that managed the identifiers linked with these samples were discussed, particularly with respect to meeting the anonymization requirements needed for Institutional Review Board exemption under the Common Rule. Current de-identification strategies have their limitations, and statistical learning-based systems have distinct advantages over other approaches for the de-identification of free text. True anonymization is challenging, and further work is needed in the areas of de-identification of datasets and protection of genetic information.
Integration of the instrument control electronics for the ESPRESSO spectrograph at ESO-VLT
NASA Astrophysics Data System (ADS)
Baldini, V.; Calderone, G.; Cirami, R.; Coretti, I.; Cristiani, S.; Di Marcantonio, P.; Mégevand, D.; Riva, M.; Santin, P.
2016-07-01
ESPRESSO, the Echelle SPectrograph for Rocky Exoplanet and Stable Spectroscopic Observations of the ESO - Very Large Telescope site, is now in its integration phase. The large number of functions of this complex instrument are fully controlled by a Beckhoff PLC based control electronics architecture. Four small and one large cabinets host the main electronic parts to control all the sensors, motorized stages and other analogue and digital functions of ESPRESSO. The Instrument Control Electronics (ICE) is built following the latest ESO standards and requirements. Two main PLC CPUs are used and are programmed through the TwinCAT Beckhoff dedicated software. The assembly, integration and verification phase of ESPRESSO, due to its distributed nature and different geographical locations of the consortium partners, is quite challenging. After the preliminary assembling and test of the electronic components at the Astronomical Observatory of Trieste and the test of some electronics and software parts at ESO (Garching), the complete system for the control of the four Front End Unit (FEU) arms of ESPRESSO has been fully assembled and tested in Merate (Italy) at the beginning of 2016. After these first tests, the system will be located at the Geneva Observatory (Switzerland) until the Preliminary Acceptance Europe (PAE) and finally shipped to Chile for the commissioning. This paper describes the integration strategy of the ICE workpackage of ESPRESSO, the hardware and software tests that have been performed, with an overall view of the experience gained during these project's phases.
Quantum logic gates based on coherent electron transport in quantum wires.
Bertoni, A; Bordone, P; Brunetti, R; Jacoboni, C; Reggiani, S
2000-06-19
It is shown that the universal set of quantum logic gates can be realized using solid-state quantum bits based on coherent electron transport in quantum wires. The elementary quantum bits are realized with a proper design of two quantum wires coupled through a potential barrier. Numerical simulations show that (a) a proper design of the coupling barrier allows one to realize any one-qbit rotation and (b) Coulomb interaction between two qbits of this kind allows the implementation of the CNOT gate. These systems are based on a mature technology and seem to be integrable with conventional electronics.
Integrated circuits and logic operations based on single-layer MoS2.
Radisavljevic, Branimir; Whitwick, Michael Brian; Kis, Andras
2011-12-27
Logic circuits and the ability to amplify electrical signals form the functional backbone of electronics along with the possibility to integrate multiple elements on the same chip. The miniaturization of electronic circuits is expected to reach fundamental limits in the near future. Two-dimensional materials such as single-layer MoS(2) represent the ultimate limit of miniaturization in the vertical dimension, are interesting as building blocks of low-power nanoelectronic devices, and are suitable for integration due to their planar geometry. Because they are less than 1 nm thin, 2D materials in transistors could also lead to reduced short channel effects and result in fabrication of smaller and more power-efficient transistors. Here, we report on the first integrated circuit based on a two-dimensional semiconductor MoS(2). Our integrated circuits are capable of operating as inverters, converting logical "1" into logical "0", with room-temperature voltage gain higher than 1, making them suitable for incorporation into digital circuits. We also show that electrical circuits composed of single-layer MoS(2) transistors are capable of performing the NOR logic operation, the basis from which all logical operations and full digital functionality can be deduced.
Phase contrast STEM for thin samples: Integrated differential phase contrast.
Lazić, Ivan; Bosch, Eric G T; Lazar, Sorin
2016-01-01
It has been known since the 1970s that the movement of the center of mass (COM) of a convergent beam electron diffraction (CBED) pattern is linearly related to the (projected) electrical field in the sample. We re-derive a contrast transfer function (CTF) for a scanning transmission electron microscopy (STEM) imaging technique based on this movement from the point of view of image formation and continue by performing a two-dimensional integration on the two images based on the two components of the COM movement. The resulting integrated COM (iCOM) STEM technique yields a scalar image that is linear in the phase shift caused by the sample and therefore also in the local (projected) electrostatic potential field of a thin sample. We confirm that the differential phase contrast (DPC) STEM technique using a segmented detector with 4 quadrants (4Q) yields a good approximation for the COM movement. Performing a two-dimensional integration, just as for the COM, we obtain an integrated DPC (iDPC) image which is approximately linear in the phase of the sample. Beside deriving the CTFs of iCOM and iDPC, we clearly point out the objects of the two corresponding imaging techniques, and highlight the differences to objects corresponding to COM-, DPC-, and (HA) ADF-STEM. The theory is validated with simulations and we present first experimental results of the iDPC-STEM technique showing its capability for imaging both light and heavy elements with atomic resolution and a good signal to noise ratio (SNR). Copyright © 2015 Elsevier B.V. All rights reserved.
Virtual temporal bone dissection system: OSU virtual temporal bone system: development and testing.
Wiet, Gregory J; Stredney, Don; Kerwin, Thomas; Hittle, Bradley; Fernandez, Soledad A; Abdel-Rasoul, Mahmoud; Welling, D Bradley
2012-03-01
The objective of this project was to develop a virtual temporal bone dissection system that would provide an enhanced educational experience for the training of otologic surgeons. A randomized, controlled, multi-institutional, single-blinded validation study. The project encompassed four areas of emphasis: structural data acquisition, integration of the system, dissemination of the system, and validation. Structural acquisition was performed on multiple imaging platforms. Integration achieved a cost-effective system. Dissemination was achieved on different levels including casual interest, downloading of software, and full involvement in development and validation studies. A validation study was performed at eight different training institutions across the country using a two-arm randomized trial where study subjects were randomized to a 2-week practice session using either the virtual temporal bone or standard cadaveric temporal bones. Eighty subjects were enrolled and randomized to one of the two treatment arms; 65 completed the study. There was no difference between the two groups using a blinded rating tool to assess performance after training. A virtual temporal bone dissection system has been developed and compared to cadaveric temporal bones for practice using a multicenter trial. There was no statistical difference between practice on the current simulator compared to practice on human cadaveric temporal bones. Further refinements in structural acquisition and interface design have been identified, which can be implemented prior to full incorporation into training programs and used for objective skills assessment. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
Sweat Chloride as A Biomarker of CFTR Activity: Proof of Concept and Ivacaftor Clinical Trial Data
Accurso, Frank J.; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J.; Dong, Qunming; Ordonez, Claudia L.; Rowe, Steven M.; Clancy, John Paul; Konstan, Michael W.; Hoch, Heather E.; Heltshe, Sonya L.; Ramsey, Bonnie W.; Campbell, Preston W.; Ashlock, Melissa A.
2014-01-01
Background We examined data from a Phase 2 trial {NCT00457821 } of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with a G551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Methods Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing, and analysis was employed for the first time.. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Results Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Conclusions Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators. PMID:24660233
Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.
Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A
2014-03-01
We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.
ImTK: an open source multi-center information management toolkit
NASA Astrophysics Data System (ADS)
Alaoui, Adil; Ingeholm, Mary Lou; Padh, Shilpa; Dorobantu, Mihai; Desai, Mihir; Cleary, Kevin; Mun, Seong K.
2008-03-01
The Information Management Toolkit (ImTK) Consortium is an open source initiative to develop robust, freely available tools related to the information management needs of basic, clinical, and translational research. An open source framework and agile programming methodology can enable distributed software development while an open architecture will encourage interoperability across different environments. The ISIS Center has conceptualized a prototype data sharing network that simulates a multi-center environment based on a federated data access model. This model includes the development of software tools to enable efficient exchange, sharing, management, and analysis of multimedia medical information such as clinical information, images, and bioinformatics data from multiple data sources. The envisioned ImTK data environment will include an open architecture and data model implementation that complies with existing standards such as Digital Imaging and Communications (DICOM), Health Level 7 (HL7), and the technical framework and workflow defined by the Integrating the Healthcare Enterprise (IHE) Information Technology Infrastructure initiative, mainly the Cross Enterprise Document Sharing (XDS) specifications.
Emission and detection of surface acoustic waves by AlGaN/GaN high electron mobility transistors
NASA Astrophysics Data System (ADS)
Shao, Lei; Zhang, Meng; Banerjee, Animesh; Bhattacharya, Pallab; Pipe, Kevin P.
2011-12-01
Using integrated interdigital transducers (IDTs), we demonstrate the emission of surface acoustic waves (SAWs) by AlGaN/GaN high electron mobility transistors (HEMTs) under certain bias conditions through dynamic screening of the HEMTs vertical field by modulation of its two-dimensional electron gas. We show that a strong SAW signal can be detected if the IDT geometry replicates the HEMT electrode geometry at which RF bias is applied. In addition to characterizing SAW emission during both gate-source and drain-source modulation, we demonstrate SAW detection by HEMTs. Integrated HEMT-IDT structures could enable real-time evaluation of epitaxial degradation as well as high-speed, amplified detection of SAWs.
NASA Astrophysics Data System (ADS)
Del Sorbo, D.; Seipt, D.; Thomas, A. G. R.; Ridgers, C. P.
2018-06-01
It has recently been suggested that two counter-propagating, circularly polarized, ultra-intense lasers can induce a strong electron spin polarization at the magnetic node of the electromagnetic field that they setup (Del Sorbo et al 2017 Phys. Rev. A 96 043407). We confirm these results by considering a more sophisticated description that integrates over realistic trajectories. The electron dynamics is weakly affected by the variation of power radiated due to the spin polarization. The degree of spin polarization differs by approximately 5% if considering electrons initially at rest or already in a circular orbit. The instability of trajectories at the magnetic node induces a spin precession associated with the electron migration that establishes an upper temporal limit to the polarization of the electron population of about one laser period.
Deformable devices with integrated functional nanomaterials for wearable electronics.
Kim, Jaemin; Lee, Jongsu; Son, Donghee; Choi, Moon Kee; Kim, Dae-Hyeong
2016-01-01
As the market and related industry for wearable electronics dramatically expands, there are continuous and strong demands for flexible and stretchable devices to be seamlessly integrated with soft and curvilinear human skin or clothes. However, the mechanical mismatch between the rigid conventional electronics and the soft human body causes many problems. Therefore, various prospective nanomaterials that possess a much lower flexural rigidity than their bulk counterparts have rapidly established themselves as promising electronic materials replacing rigid silicon and/or compound semiconductors in next-generation wearable devices. Many hybrid structures of multiple nanomaterials have been also developed to pursue both high performance and multifunctionality. Here, we provide an overview of state-of-the-art wearable devices based on one- or two-dimensional nanomaterials (e.g., carbon nanotubes, graphene, single-crystal silicon and oxide nanomembranes, organic nanomaterials and their hybrids) in combination with zero-dimensional functional nanomaterials (e.g., metal/oxide nanoparticles and quantum dots). Starting from an introduction of materials strategies, we describe device designs and the roles of individual ones in integrated systems. Detailed application examples of wearable sensors/actuators, memories, energy devices, and displays are also presented.
Deformable devices with integrated functional nanomaterials for wearable electronics
NASA Astrophysics Data System (ADS)
Kim, Jaemin; Lee, Jongsu; Son, Donghee; Choi, Moon Kee; Kim, Dae-Hyeong
2016-03-01
As the market and related industry for wearable electronics dramatically expands, there are continuous and strong demands for flexible and stretchable devices to be seamlessly integrated with soft and curvilinear human skin or clothes. However, the mechanical mismatch between the rigid conventional electronics and the soft human body causes many problems. Therefore, various prospective nanomaterials that possess a much lower flexural rigidity than their bulk counterparts have rapidly established themselves as promising electronic materials replacing rigid silicon and/or compound semiconductors in next-generation wearable devices. Many hybrid structures of multiple nanomaterials have been also developed to pursue both high performance and multifunctionality. Here, we provide an overview of state-of-the-art wearable devices based on one- or two-dimensional nanomaterials (e.g., carbon nanotubes, graphene, single-crystal silicon and oxide nanomembranes, organic nanomaterials and their hybrids) in combination with zero-dimensional functional nanomaterials (e.g., metal/oxide nanoparticles and quantum dots). Starting from an introduction of materials strategies, we describe device designs and the roles of individual ones in integrated systems. Detailed application examples of wearable sensors/actuators, memories, energy devices, and displays are also presented.
Haase, Rocco; Schultheiss, Thorsten; Kempcke, Raimar; Thomas, Katja; Ziemssen, Tjalf
2012-10-15
The number of multiple sclerosis (MS) information websites, online communities, and Web-based health education programs has been increasing. However, MS patients' willingness to use new ways of communication, such as websites, mobile phone application, short message service, or email with their physician, remains unknown. We designed a questionnaire to evaluate the a priori use of electronic communication methods by MS patients and to assess their acceptance of such tools for communication with their health care providers. We received complete data from 586 MS patients aged between 17 and 73 years. Respondents were surveyed in outpatient clinics across Germany using a novel paper-and-pencil questionnaire. In addition to demographics, the survey items queried frequency of use of, familiarity with, and comfort with using computers, websites, email, and mobile phones. About 90% of all MS patients used a personal computer (534/586) and the Internet (527/586) at least once a week, 87.0% (510/586) communicated by email, and 85.6% (488/570) communicated by mobile phone. When asked about their comfort with using electronic communication methods for communication with health care providers, 20.5% (120/586) accepted communication by mobile Internet application or short message service via mobile phone, 41.0% (240/586) by websites, 54.3% (318/586) by email service, and 67.8% (397/586) by at least one type of electronic communication. The level of a priori use was the best predictor for the acceptance of electronic communication with health care providers. Patients who reported already searching online for health information (odds ratio 2.4, P < .001) and who had already communicated with a physician through a website (odds ratio 3.3, P = .03) reported higher acceptance for Web-based communication. Patients who already scheduled appointments with their mobile phones (odds ratio 2.1, P = .002) were more likely to accept the use of mobile phone applications or short message service for communicating with their physician. The majority of MS patients seen at specialist centers already use modern communication technology regularly. New forms of electronic communication appear to have high levels of acceptance for exchanging information about MS between patients and health care providers. Such methods should be integrated into eHealth services such as electronic health records and patient relationship management systems.
Thimmaiah, Srinivasa; Miller, Gordon J.
2015-06-03
A series of pseudo-binary compounds MgZn 2-xPd x (0.15 ≤ x ≤ 1.0) were synthesized and structurally characterized to understand the role of valence electron concentration (vec) on the prototype Laves phase MgZn 2 with Pd-substitution. Three distinctive phase regions were observed with respect to Pd content, all exhibiting fundamental Laves phase structures: 0.1 ≤ x ≤ 0.3 (MgNi 2-type, hP24; MgZn 1.80Pd 0.20(2)), 0.4 ≤ x ≤ 0.6 (MgCu 2-type, cF24; MgZn 1.59Pd 0.41(2)), and 0.62 ≤ x ≤ 0.8 (MgZn 2-type, hP12: MgZn 1.37Pd 0.63(2)). Refinements from single-crystal X-ray diffraction indicated nearly statistical distributions of Pd and Znmore » atoms among the majority atom sites in these structures. Interestingly, the MgZn 2-type structure re-emerges in MgZn 2–xPd x at x ≈ 0.7 with the refined composition MgZn 1.37(2)Pd 0.63 and a c/a ratio of 1.59 compared to 1.64 for binary MgZn 2. Electronic structure calculations on a model “MgZn 1.25Pd 0.75” yielded a density of states (DOS) curve showing enhancement of a pseudogap at the Fermi level as a result of electronic stabilization due to the Pd addition. Moreover, integrated crystal orbital Hamilton population values show significant increases of orbital interactions for (Zn,Pd)–(Zn,Pd) atom pairs within the majority atom substructure, i.e., within the Kagomé nets as well as between a Kagomé net and an apical site, from binary MgZn 2 to the ternary “MgZn 1.25Pd 0.75”. Multi-centered bonding is evident from electron localization function plots for “MgZn 1.25Pd 0.75”, an outcome which is in accordance with analysis of other Laves phases.« less
Geer, Eliza B; Shafiq, Ismat; Gordon, Murray B; Bonert, Vivien; Ayala, Alejandro; Swerdloff, Ronald S; Katznelson, Laurence; Lalazar, Yelena; Manuylova, Ekaterina; Pulaski-Liebert, Karen J; Carmichael, John D; Hannoush, Zeina; Surampudi, Vijaya; Broder, Michael S; Cherepanov, Dasha; Eagan, Marianne; Lee, Jackie; Said, Qayyim; Neary, Maureen P; Biller, Beverly M K
2017-08-01
Cushing disease (CD) results from excessive exposure to glucocorticoids caused by an adrenocorticotropic hormone-secreting pituitary tumor. Inadequately treated CD is associated with significant morbidity and elevated mortality. Multicenter data on CD patients treated in routine clinical practice are needed to assess treatment outcomes in this rare disorder. The study purpose was to describe the burden of illness and treatment outcomes for CD patients. Eight pituitary centers in four U.S. regions participated in this multicenter retrospective chart review study. Subjects were CD patients diagnosed at ≥18 years of age within the past 20 years. Descriptive statistical analyses were conducted to examine presenting signs, symptoms, comorbidities, and treatment outcomes. Of 230 patients, 79% were female (median age at diagnosis, 39 years; range, 18 to 78 years). Length of follow-up was 0 to 27.5 years (median, 1.9 years). Pituitary adenomas were 0 to 51 mm. The most common presenting comorbidities included hypertension (67.3%), polycystic ovary syndrome (43.5%), and hyperlipidemia (41.5%). Biochemical control was achieved with initial pituitary surgery in 41.4% patients (91 of 220), not achieved in 50.0% of patients (110 of 220), and undetermined in 8.6% of patients (19 of 220). At the end of follow-up, control had been achieved with a variety of treatment methods in 49.1% of patients (110 of 224), not achieved in 29.9% of patients (67 of 224), and undetermined in 21.0% of patients (47 of 224). Despite multiple treatments, at the end of follow-up, biochemical control was still not achieved in up to 30% of patients. These multicenter data demonstrate that in routine clinical practice, initial and long-term control is not achieved in a substantial number of patients with CD. BLA = bilateral adrenalectomy CD = Cushing disease CS = Cushing syndrome eCRF = electronic case report form MRI = magnetic resonance imaging PCOS = polycystic ovary syndrome.
Retrieval of the Leadless Cardiac Pacemaker: A Multicenter Experience.
Reddy, Vivek Y; Miller, Marc A; Knops, Reinoud E; Neuzil, Petr; Defaye, Pascal; Jung, Werner; Doshi, Rahul; Castellani, Mark; Strickberger, Adam; Mead, R Hardwin; Doppalapudi, Harish; Lakkireddy, Dhanunjaya; Bennett, Matthew; Sperzel, Johannes
2016-12-01
Leadless cardiac pacemakers have emerged as a safe and effective alternative to conventional transvenous single-chamber ventricular pacemakers. Herein, we report a multicenter experience on the feasibility and safety of acute retrieval (<6 weeks) and chronic retrieval (>6 weeks) of the leadless cardiac pacemaker in humans. This study included patients enrolled in 3 multicenter trials, who received a leadless cardiac pacemaker implant and who subsequently underwent a device removal attempt. The overall leadless pacemaker retrieval success rate was 94%: for patients whose leadless cardiac pacemaker had been implanted for <6 weeks (acute retrieval cohort), complete retrieval was achieved in 100% (n=5/5); for those implanted for ≥ 6 weeks (chronic retrieval cohort), retrieval was achieved in 91% (n=10/11) of patients. The mean duration of time from implant to retrieval attempt was 346 days (range, 88-1188 days) in the chronic retrieval cohort, and nearly two thirds (n=7; 63%) had been implanted for >6 months before the retrieval attempt. There were no procedure-related adverse events at 30 days post retrieval procedure. This multicenter experience demonstrated the feasibility and safety of retrieving a chronically implanted single-chamber (right ventricle) active fixation leadless pacemaker. URL: https://www.clinicaltrials.gov. Unique identifiers: NCT02051972, NCT02030418, and NCT01700244. © 2016 American Heart Association, Inc.
Dissolvable tattoo sensors: from science fiction to a viable technology
NASA Astrophysics Data System (ADS)
Cheng, Huanyu; Yi, Ning
2017-01-01
Early surrealistic painting and science fiction movies have envisioned dissolvable tattoo electronic devices. In this paper, we will review the recent advances that transform that vision into a viable technology, with extended capabilities even beyond the early vision. Specifically, we focus on the discussion of a stretchable design for tattoo sensors and degradable materials for dissolvable sensors, in the form of inorganic devices with a performance comparable to modern electronics. Integration of these two technologies as well as the future developments of bio-integrated devices is also discussed. Many of the appealing ideas behind developments of these devices are drawn from nature and especially biological systems. Thus, bio-inspiration is believed to continue playing a key role in future devices for bio-integration and beyond.
Integrated digital inverters based on two-dimensional anisotropic ReS2 field-effect transistors
Liu, Erfu; Fu, Yajun; Wang, Yaojia; Feng, Yanqing; Liu, Huimei; Wan, Xiangang; Zhou, Wei; Wang, Baigeng; Shao, Lubin; Ho, Ching-Hwa; Huang, Ying-Sheng; Cao, Zhengyi; Wang, Laiguo; Li, Aidong; Zeng, Junwen; Song, Fengqi; Wang, Xinran; Shi, Yi; Yuan, Hongtao; Hwang, Harold Y.; Cui, Yi; Miao, Feng; Xing, Dingyu
2015-01-01
Semiconducting two-dimensional transition metal dichalcogenides are emerging as top candidates for post-silicon electronics. While most of them exhibit isotropic behaviour, lowering the lattice symmetry could induce anisotropic properties, which are both scientifically interesting and potentially useful. Here we present atomically thin rhenium disulfide (ReS2) flakes with unique distorted 1T structure, which exhibit in-plane anisotropic properties. We fabricated monolayer and few-layer ReS2 field-effect transistors, which exhibit competitive performance with large current on/off ratios (∼107) and low subthreshold swings (100 mV per decade). The observed anisotropic ratio along two principle axes reaches 3.1, which is the highest among all known two-dimensional semiconducting materials. Furthermore, we successfully demonstrated an integrated digital inverter with good performance by utilizing two ReS2 anisotropic field-effect transistors, suggesting the promising implementation of large-scale two-dimensional logic circuits. Our results underscore the unique properties of two-dimensional semiconducting materials with low crystal symmetry for future electronic applications. PMID:25947630
A self-consistent two-fluid model of a magnetized plasma-wall transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gyergyek, T.; Jožef Stefan Institute, Jamova 39, P.O. Box 100, 1000 Ljubljana; Kovačič, J.
A self-consistent one-dimensional two-fluid model of the magnetized plasma-wall transition is presented. The model includes magnetic field, elastic collisions between ions and electrons, and creation/annihilation of charged particles. Two systems of differential equations are derived. The first system describes the whole magnetized plasma-wall transition region, which consists of the pre-sheath, the magnetized pre-sheath (Chodura layer), and the sheath, which is not neutral, but contains a positive space charge. The second system of equations describes only the neutral part of the plasma-wall transition region—this means only the pre-sheath and the Chodura layer, but not also the sheath. Both systems are solvedmore » numerically. The first system of equations has two singularities. The first occurs when ion velocity in the direction perpendicularly to the wall drops below the ion thermal velocity. The second occurs when the electron velocity in the direction perpendicularly to the wall exceeds the electron thermal velocity. The second system of differential equations only has one singularity, which has also been derived analytically. For finite electron to ion mass ratio, the integration of the second system always breaks down before the Bohm criterion is fulfilled. Some properties of the first system of equations are examined. It is shown that the increased collision frequency demagnetizes the plasma. On the other hand, if the magnetic field is so strong that the ion Larmor radius and the Debye length are comparable, the electron velocity in the direction perpendicularly to the wall reaches the electron thermal velocity before the ion velocity in the direction perpendicularly to the wall reaches the ion sound velocity. In this case, the integration of the model equations breaks down before the Bohm criterion is fulfilled and the sheath is formed.« less
Electronic Media and Youth Violence: A CDC Issue Brief for Researchers
ERIC Educational Resources Information Center
David-Ferdon, Corinne; Hertz, Marci Feldman
2009-01-01
Electronic media play an integral role in the lives of all people. Over the years, the rapid evolution of technology in various forms has significantly influenced the way people live and interact. Televisions, record players, computers, and VCRs changed how people learned, were entertained, stayed connected, and explored. In the past two decades,…
The Need for Optical Means as an Alternative for Electronic Computing
NASA Technical Reports Server (NTRS)
Adbeldayem, Hossin; Frazier, Donald; Witherow, William; Paley, Steve; Penn, Benjamin; Bank, Curtis; Whitaker, Ann F. (Technical Monitor)
2001-01-01
An increasing demand for faster computers is rapidly growing to encounter the fast growing rate of Internet, space communication, and robotic industry. Unfortunately, the Very Large Scale Integration technology is approaching its fundamental limits beyond which the device will be unreliable. Optical interconnections and optical integrated circuits are strongly believed to provide the way out of the extreme limitations imposed on the growth of speed and complexity of nowadays computations by conventional electronics. This paper demonstrates two ultra-fast, all-optical logic gates and a high-density storage medium, which are essential components in building the future optical computer.
Podor, Renaud; Pailhon, Damien; Ravaux, Johann; Brau, Henri-Pierre
2015-04-01
We have developed two integrated thermocouple (TC) crucible systems that allow precise measurement of sample temperature when using a furnace associated with an environmental scanning electron microscope (ESEM). Sample temperatures measured with these systems are precise (±5°C) and reliable. The TC crucible systems allow working with solids and liquids (silicate melts or ionic liquids), independent of the gas composition and pressure. These sample holder designs will allow end users to perform experiments at high temperature in the ESEM chamber with high precision control of the sample temperature.
Two-component relativistic coupled-cluster methods using mean-field spin-orbit integrals
NASA Astrophysics Data System (ADS)
Liu, Junzi; Shen, Yue; Asthana, Ayush; Cheng, Lan
2018-01-01
A novel implementation of the two-component spin-orbit (SO) coupled-cluster singles and doubles (CCSD) method and the CCSD augmented with the perturbative inclusion of triple excitations [CCSD(T)] method using mean-field SO integrals is reported. The new formulation of SO-CCSD(T) features an atomic-orbital-based algorithm for the particle-particle ladder term in the CCSD equation, which not only removes the computational bottleneck associated with the large molecular-orbital integral file but also accelerates the evaluation of the particle-particle ladder term by around a factor of 4 by taking advantage of the spin-free nature of the instantaneous electron-electron Coulomb interaction. Benchmark calculations of the SO splittings for the thallium atom and a set of diatomic 2Π radicals as well as of the bond lengths and harmonic frequencies for a set of closed-shell diatomic molecules are presented. The basis-set and core-correlation effects in the calculations of these properties have been carefully analyzed.
Jibb, Lindsay A; Nathan, Paul C; Stevens, Bonnie J; Seto, Emily; Cafazzo, Joseph A; Stephens, Nisha; Yohannes, Liza; Stinson, Jennifer N
2015-11-01
To identify and appraise current evidence related to the effectiveness of psychological and physical (nonpharmacologic) pain management modalities for children and young adults with cancer . Electronic searches in MEDLINE, EMBASE, CINAHL, PsycINFO, and Web of Science (from database inception to June 2013) for clinical trials. A total of 32 unique studies were identified. Substantial heterogeneity existed across identified studies, precluding meta-analysis. Therefore, a narrative review of included studies is presented. Studies featured psychological and/or physical pain interventions for children and young adults (N = 1,171) aged 1-21 years with a variety of cancer diagnoses. Interventions included aromatherapy, art therapy, distraction, hypnosis, physical activity, physical positioning, touch therapy, and multimodal cognitive-behavior therapy. Twenty-two studies (69%) reported success in preventing or reducing pain intensity. The level of evidence and methodologic quality of studies were generally low . Current nonpharmacologic pain interventions for pediatric and young adult patients with cancer are diverse. Several modalities significantly decreased pain intensity, suggesting that these strategies may be effective methods of pain treatment, particularly in the case of painful medical procedures. Future well-designed, multicenter, randomized, controlled trials are needed to further discern treatment effects on pain and other health outcomes in this population and to compare the relative effectiveness of different modalities. Nurses play a key role in pain assessment and management in pediatric and young adult patients with cancer. The studies included in this review constitute the beginnings of an evidence base that supports the need to implement psychological and physical interventions to improve pain outcomes in pediatric and young adult patients with cancer.
NASA Astrophysics Data System (ADS)
Litts, Breanne K.; Kafai, Yasmin B.; Lui, Debora A.; Walker, Justice T.; Widman, Sari A.
2017-10-01
Learning about circuitry by connecting a battery, light bulb, and wires is a common activity in many science classrooms. In this paper, we expand students' learning about circuitry with electronic textiles, which use conductive thread instead of wires and sewable LEDs instead of lightbulbs, by integrating programming sensor inputs and light outputs and examining how the two domains interact. We implemented an electronic textiles unit with 23 high school students ages 16-17 years who learned how to craft and code circuits with the LilyPad Arduino, an electronic textile construction kit. Our analyses not only confirm significant increases in students' understanding of functional circuits but also showcase students' ability in designing and remixing program code for controlling circuits. In our discussion, we address opportunities and challenges of introducing codeable circuit design for integrating maker activities that include engineering and computing into classrooms.
Hybrid Nanowire Ion-to-Electron Transducers for Integrated Bioelectronic Circuitry.
Carrad, D J; Mostert, A B; Ullah, A R; Burke, A M; Joyce, H J; Tan, H H; Jagadish, C; Krogstrup, P; Nygård, J; Meredith, P; Micolich, A P
2017-02-08
A key task in the emerging field of bioelectronics is the transduction between ionic/protonic and electronic signals at high fidelity. This is a considerable challenge since the two carrier types exhibit intrinsically different physics and are best supported by very different materials types-electronic signals in inorganic semiconductors and ionic/protonic signals in organic or bio-organic polymers, gels, or electrolytes. Here we demonstrate a new class of organic-inorganic transducing interface featuring semiconducting nanowires electrostatically gated using a solid proton-transporting hygroscopic polymer. This model platform allows us to study the basic transducing mechanisms as well as deliver high fidelity signal conversion by tapping into and drawing together the best candidates from traditionally disparate realms of electronic materials research. By combining complementary n- and p-type transducers we demonstrate functional logic with significant potential for scaling toward high-density integrated bioelectronic circuitry.
Paper-based piezoelectric touch pads with hydrothermally grown zinc oxide nanowires.
Li, Xiao; Wang, Yu-Hsuan; Zhao, Chen; Liu, Xinyu
2014-12-24
This paper describes a new type of paper-based piezoelectric touch pad integrating zinc oxide nanowires (ZnO NWs), which can serve as user interfaces in paper-based electronics. The sensing functionality of these touch pads is enabled by the piezoelectric property of ZnO NWs grown on paper using a simple, cost-efficient hydrothermal method. A piece of ZnO-NW paper with two screen-printed silver electrodes forms a touch button, and touch-induced electric charges from the button are converted into a voltage output using a charge amplifier circuit. A touch pad consisting of an array of buttons can be readily integrated into paper-based electronic devices, allowing user input of information for various purposes such as programming, identification checking, and gaming. This novel design features ease of fabrication, low cost, ultrathin structure, and good compatibility with techniques in printed electronics, and further enriches the available technologies of paper-based electronics.
Spiers Memorial Lecture. Molecular mechanics and molecular electronics.
Beckman, Robert; Beverly, Kris; Boukai, Akram; Bunimovich, Yuri; Choi, Jang Wook; DeIonno, Erica; Green, Johnny; Johnston-Halperin, Ezekiel; Luo, Yi; Sheriff, Bonnie; Stoddart, Fraser; Heath, James R
2006-01-01
We describe our research into building integrated molecular electronics circuitry for a diverse set of functions, and with a focus on the fundamental scientific issues that surround this project. In particular, we discuss experiments aimed at understanding the function of bistable rotaxane molecular electronic switches by correlating the switching kinetics and ground state thermodynamic properties of those switches in various environments, ranging from the solution phase to a Langmuir monolayer of the switching molecules sandwiched between two electrodes. We discuss various devices, low bit-density memory circuits, and ultra-high density memory circuits that utilize the electrochemical switching characteristics of these molecules in conjunction with novel patterning methods. We also discuss interconnect schemes that are capable of bridging the micrometre to submicrometre length scales of conventional patterning approaches to the near-molecular length scales of the ultra-dense memory circuits. Finally, we discuss some of the challenges associated with fabricated ultra-dense molecular electronic integrated circuits.
Understanding boron through size-selected clusters: structure, chemical bonding, and fluxionality.
Sergeeva, Alina P; Popov, Ivan A; Piazza, Zachary A; Li, Wei-Li; Romanescu, Constantin; Wang, Lai-Sheng; Boldyrev, Alexander I
2014-04-15
Boron is an interesting element with unusual polymorphism. While three-dimensional (3D) structural motifs are prevalent in bulk boron, atomic boron clusters are found to have planar or quasi-planar structures, stabilized by localized two-center-two-electron (2c-2e) σ bonds on the periphery and delocalized multicenter-two-electron (nc-2e) bonds in both σ and π frameworks. Electron delocalization is a result of boron's electron deficiency and leads to fluxional behavior, which has been observed in B13(+) and B19(-). A unique capability of the in-plane rotation of the inner atoms against the periphery of the cluster in a chosen direction by employing circularly polarized infrared radiation has been suggested. Such fluxional behaviors in boron clusters are interesting and have been proposed as molecular Wankel motors. The concepts of aromaticity and antiaromaticity have been extended beyond organic chemistry to planar boron clusters. The validity of these concepts in understanding the electronic structures of boron clusters is evident in the striking similarities of the π-systems of planar boron clusters to those of polycyclic aromatic hydrocarbons, such as benzene, naphthalene, coronene, anthracene, or phenanthrene. Chemical bonding models developed for boron clusters not only allowed the rationalization of the stability of boron clusters but also lead to the design of novel metal-centered boron wheels with a record-setting planar coordination number of 10. The unprecedented highly coordinated borometallic molecular wheels provide insights into the interactions between transition metals and boron and expand the frontier of boron chemistry. Another interesting feature discovered through cluster studies is boron transmutation. Even though it is well-known that B(-), formed by adding one electron to boron, is isoelectronic to carbon, cluster studies have considerably expanded the possibilities of new structures and new materials using the B(-)/C analogy. It is believed that the electronic transmutation concept will be effective and valuable in aiding the design of new boride materials with predictable properties. The study of boron clusters with intermediate properties between those of individual atoms and bulk solids has given rise to a unique opportunity to broaden the frontier of boron chemistry. Understanding boron clusters has spurred experimentalists and theoreticians to find new boron-based nanomaterials, such as boron fullerenes, nanotubes, two-dimensional boron, and new compounds containing boron clusters as building blocks. Here, a brief and timely overview is presented addressing the recent progress made on boron clusters and the approaches used in the authors' laboratories to determine the structure, stability, and chemical bonding of size-selected boron clusters by joint photoelectron spectroscopy and theoretical studies. Specifically, key findings on all-boron hydrocarbon analogues, metal-centered boron wheels, and electronic transmutation in boron clusters are summarized.
Min, Yul Ha; Park, Hyeoun-Ae; Chung, Eunja; Lee, Hyunsook
2013-12-01
The purpose of this paper is to describe the components of a next-generation electronic nursing records system ensuring full semantic interoperability and integrating evidence into the nursing records system. A next-generation electronic nursing records system based on detailed clinical models and clinical practice guidelines was developed at Seoul National University Bundang Hospital in 2013. This system has two components, a terminology server and a nursing documentation system. The terminology server manages nursing narratives generated from entity-attribute-value triplets of detailed clinical models using a natural language generation system. The nursing documentation system provides nurses with a set of nursing narratives arranged around the recommendations extracted from clinical practice guidelines. An electronic nursing records system based on detailed clinical models and clinical practice guidelines was successfully implemented in a hospital in Korea. The next-generation electronic nursing records system can support nursing practice and nursing documentation, which in turn will improve data quality.
NASA Technical Reports Server (NTRS)
Berman, A. L.
1977-01-01
Observations of Viking differenced S-band/X-band (S-X) range are shown to correlate strongly with Viking Doppler noise. A ratio of proportionality between downlink S-band plasma-induced range error and two-way Doppler noise is calculated. A new parameter (similar to the parameter epsilon which defines the ratio of local electron density fluctuations to mean electron density) is defined as a function of observed data sample interval (Tau) where the time-scale of the observations is 15 Tau. This parameter is interpreted to yield the ratio of net observed phase (or electron density) fluctuations to integrated electron density (in RMS meters/meter). Using this parameter and the thin phase-changing screen approximation, a value for the scale size L is calculated. To be consistent with Doppler noise observations, it is seen necessary for L to be proportional to closest approach distance a, and a strong function of the observed data sample interval, and hence the time-scale of the observations.
New Fukui, dual and hyper-dual kernels as bond reactivity descriptors.
Franco-Pérez, Marco; Polanco-Ramírez, Carlos-A; Ayers, Paul W; Gázquez, José L; Vela, Alberto
2017-06-21
We define three new linear response indices with promising applications for bond reactivity using the mathematical framework of τ-CRT (finite temperature chemical reactivity theory). The τ-Fukui kernel is defined as the ratio between the fluctuations of the average electron density at two different points in the space and the fluctuations in the average electron number and is designed to integrate to the finite-temperature definition of the electronic Fukui function. When this kernel is condensed, it can be interpreted as a site-reactivity descriptor of the boundary region between two atoms. The τ-dual kernel corresponds to the first order response of the Fukui kernel and is designed to integrate to the finite temperature definition of the dual descriptor; it indicates the ambiphilic reactivity of a specific bond and enriches the traditional dual descriptor by allowing one to distinguish between the electron-accepting and electron-donating processes. Finally, the τ-hyper dual kernel is defined as the second-order derivative of the Fukui kernel and is proposed as a measure of the strength of ambiphilic bonding interactions. Although these quantities have never been proposed, our results for the τ-Fukui kernel and for τ-dual kernel can be derived in zero-temperature formulation of the chemical reactivity theory with, among other things, the widely-used parabolic interpolation model.
Efficient two-component relativistic method for large systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakai, Hiromi; Research Institute for Science and Engineering, Waseda University, Tokyo 169-8555; CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012
This paper reviews a series of theoretical studies to develop efficient two-component (2c) relativistic method for large systems by the author’s group. The basic theory is the infinite-order Douglas-Kroll-Hess (IODKH) method for many-electron Dirac-Coulomb Hamiltonian. The local unitary transformation (LUT) scheme can effectively produce the 2c relativistic Hamiltonian, and the divide-and-conquer (DC) method can achieve linear-scaling of Hartree-Fock and electron correlation methods. The frozen core potential (FCP) theoretically connects model potential calculations with the all-electron ones. The accompanying coordinate expansion with a transfer recurrence relation (ACE-TRR) scheme accelerates the computations of electron repulsion integrals with high angular momenta and longmore » contractions.« less
Kerr, David; Hoogma, Roel P.L.M; Buhr, Andreas; Petersen, Bettina; Storms, Fred E.M.G
2010-01-01
Background The aim of this study was to evaluate a newly developed system for insulin delivery incorporating a multifunctional blood glucose meter and a remotely controlled insulin pump (ACCU-CHEK® Combo system) in established pump users with type 1 diabetes. The technology was assessed both from device performance and subject usability perspectives. Method A multicenter, prospective, single group study was carried out in five centers in the Netherlands and four centers in the United Kingdom for more than 6 months. The study was divided into two phases: Phase 1 (4 weeks) for device validation purposes and phase 2 (22 weeks) to observe the impact of the system on metabolic control, patient satisfaction [using the Diabetes Treatment Satisfaction Questionnaire (DTSQ)] and device safety. Results Eighty subjects completed the planned study period. There were no unexpected device errors. Treatment satisfaction was high at baseline and further increased to study end (DTSQ change version: sum score, 10.6 ± 7.2; scale score range, -18 to +18, p < 0.0001). Hemoglobin A1c improved continuously over time, from 7.9% (±0.9%) to 7.7% (±0.8%) at month 3 (p < 0.001) and 7.6% (±0.8%) at month 6 (p < 0.0001). The frequency of severe hypoglycemia was 0.08 per patient years. There was no case of ketoacidosis. Conclusions The new system was evaluated by experienced continuous subcutaneous insulin infusion users as safe in daily practice and associated with favorable treatment satisfaction and a modest improvement in glycemic control. PMID:21129336
NASA Astrophysics Data System (ADS)
Joubert-Doriol, Loïc; Izmaylov, Artur F.
2018-03-01
A new methodology of simulating nonadiabatic dynamics using frozen-width Gaussian wavepackets within the moving crude adiabatic representation with the on-the-fly evaluation of electronic structure is presented. The main feature of the new approach is the elimination of any global or local model representation of electronic potential energy surfaces; instead, the electron-nuclear interaction is treated explicitly using the Gaussian integration. As a result, the new scheme does not introduce any uncontrolled approximations. The employed variational principle ensures the energy conservation and leaves the number of electronic and nuclear basis functions as the only parameter determining the accuracy. To assess performance of the approach, a model with two electronic and two nuclear spacial degrees of freedom containing conical intersections between potential energy surfaces has been considered. Dynamical features associated with nonadiabatic transitions and nontrivial geometric (or Berry) phases were successfully reproduced within a limited basis expansion.
HDU Deep Space Habitat (DSH) Overview
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.
2011-01-01
This paper gives an overview of the National Aeronautics and Space Administration (NASA) led multi-center Habitat Demonstration Unit (HDU) project Deep Space Habitat (DSH) analog that will be field-tested during the 2011 Desert Research and Technologies Studies (D-RATS) field tests. The HDU project is a technology pull project that integrates technologies and innovations from multiple NASA centers. This project will repurpose the HDU Pressurized Excursion Module (PEM) that was field tested in the 2010 D-RATS, adding habitation functionality to the prototype unit. The 2010 configuration of the HDU-PEM consisted of a lunar surface laboratory module that was used to bring over 20 habitation-related technologies together in a single platform that could be tested as an advanced habitation analog in the context of mission architectures and surface operations. The 2011 HDU-DSH configuration will build upon the PEM work, and emphasize validity of crew operations (habitation and living, etc), EVA operations, mission operations, logistics operations, and science operations that might be required in a deep space context for Near Earth Object (NEO) exploration mission architectures. The HDU project consists of a multi-center team brought together in a skunkworks approach to quickly build and validate hardware in analog environments. The HDU project is part of the strategic plan from the Exploration Systems Mission Directorate (ESMD) Directorate Integration Office (DIO) and the Exploration Mission Systems Office (EMSO) to test destination elements in analog environments. The 2011 analog field test will include Multi Mission Space Exploration Vehicles (MMSEV) and the DSH among other demonstration elements to be brought together in a mission architecture context. This paper will describe overall objectives, various habitat configurations, strategic plan, and technology integration as it pertains to the 2011 field tests.
Method for integrating microelectromechanical devices with electronic circuitry
Barron, Carole C.; Fleming, James G.; Montague, Stephen
1999-01-01
A method is disclosed for integrating one or more microelectromechanical (MEM) devices with electronic circuitry on a common substrate. The MEM device can be fabricated within a substrate cavity and encapsulated with a sacrificial material. This allows the MEM device to be annealed and the substrate planarized prior to forming electronic circuitry on the substrate using a series of standard processing steps. After fabrication of the electronic circuitry, the electronic circuitry can be protected by a two-ply protection layer of titanium nitride (TiN) and tungsten (W) during an etch release process whereby the MEM device is released for operation by etching away a portion of a sacrificial material (e.g. silicon dioxide or a silicate glass) that encapsulates the MEM device. The etch release process is preferably performed using a mixture of hydrofluoric acid (HF) and hydrochloric acid (HCI) which reduces the time for releasing the MEM device compared to use of a buffered oxide etchant. After release of the MEM device, the TiN:W protection layer can be removed with a peroxide-based etchant without damaging the electronic circuitry.
Evaluation of a Teleform-based data collection system: a multi-center obesity research case study.
Jenkins, Todd M; Wilson Boyce, Tawny; Akers, Rachel; Andringa, Jennifer; Liu, Yanhong; Miller, Rosemary; Powers, Carolyn; Ralph Buncher, C
2014-06-01
Utilizing electronic data capture (EDC) systems in data collection and management allows automated validation programs to preemptively identify and correct data errors. For our multi-center, prospective study we chose to use TeleForm, a paper-based data capture software that uses recognition technology to create case report forms (CRFs) with similar functionality to EDC, including custom scripts to identify entry errors. We quantified the accuracy of the optimized system through a data audit of CRFs and the study database, examining selected critical variables for all subjects in the study, as well as an audit of all variables for 25 randomly selected subjects. Overall we found 6.7 errors per 10,000 fields, with similar estimates for critical (6.9/10,000) and non-critical (6.5/10,000) variables-values that fall below the acceptable quality threshold of 50 errors per 10,000 established by the Society for Clinical Data Management. However, error rates were found to widely vary by type of data field, with the highest rate observed with open text fields. Copyright © 2014 Elsevier Ltd. All rights reserved.
Monolithically Integrated Flexible Black Phosphorus Complementary Inverter Circuits.
Liu, Yuanda; Ang, Kah-Wee
2017-07-25
Two-dimensional (2D) inverters are a fundamental building block for flexible logic circuits which have previously been realized by heterogeneously wiring transistors with two discrete channel materials. Here, we demonstrate a monolithically integrated complementary inverter made using a homogeneous black phosphorus (BP) nanosheet on flexible substrates. The digital logic inverter circuit is demonstrated via effective threshold voltage tuning within a single BP material, which offers both electron and hole dominated conducting channels with nearly symmetric pinch-off and current saturation. Controllable electron concentration is achieved by accurately modulating the aluminum (Al) donor doping, which realizes BP n-FET with a room-temperature on/off ratio >10 3 . Simultaneously, work function engineering is employed to obtain a low Schottky barrier contact electrode that facilities hole injection, thus enhancing the current density of the BP p-FET by 9.4 times. The flexible inverter circuit shows a clear digital logic voltage inversion operation along with a larger-than-unity direct current voltage gain, while exhibits alternating current dynamic signal switching at a record high frequency up to 100 kHz and remarkable electrical stability upon mechanical bending with a radii as small as 4 mm. Our study demonstrates a practical monolithic integration strategy for achieving functional logic circuits on one material platform, paving the way for future high-density flexible electronic applications.
Automatic integration of data from dissimilar sensors
NASA Astrophysics Data System (ADS)
Citrin, W. I.; Proue, R. W.; Thomas, J. W.
The present investigation is concerned with the automatic integration of radar and electronic support measures (ESM) sensor data, and with the development of a method for the automatical integration of identification friend or foe (IFF) and radar sensor data. On the basis of the two considered proojects, significant advances have been made in the areas of sensor data integration. It is pointed out that the log likelihood approach in sensor data correlation is appropriate for both similar and dissimilar sensor data. Attention is given to the real time integration of radar and ESM sensor data, and a radar ESM correlation simulation program.
Effects of Charge-Transfer Excitons on the Photophysics of Organic Semiconductors
NASA Astrophysics Data System (ADS)
Hestand, Nicholas J.
The field of organic electronics has received considerable attention over the past several years due to the promise of novel electronic materials that are cheap, flexible and light weight. While some devices based on organic materials have already emerged on the market (e.g. organic light emitting diodes), a deeper understanding of the excited states within the condensed phase is necessary both to improve current commercial products and to develop new materials for applications that are currently in the commercial pipeline (e.g. organic photovoltaics, wearable displays, and field effect transistors). To this end, a model for pi-conjugated molecular aggregates and crystals is developed and analyzed. The model considers two types of electronic excitations, namely Frenkel and charge-transfer excitons, both of which play a prominent role in determining the nature of the excited states within tightly-packed organic systems. The former consist of an electron-hole pair bound to the same molecule while in the later the electron and hole are located on different molecules. The model also considers the important nuclear reorganization that occurs when the system switches between electronic states. This is achieved using a Holstein-style Hamiltonian that includes linear vibronic coupling of the electronic states to the nuclear motion associated with the high frequency vinyl-stretching and ring-breathing modes. Analysis of the model reveals spectroscopic signatures of charge-transfer mediated J- and H-aggregation in systems where the photophysical properties are determined primarily by charge-transfer interactions. Importantly, such signatures are found to be sensitive to the relative phase of the intermolecular electron and hole transfer integrals, and the relative energy of the Frenkel and charge-transfer states. When the charge-transfer integrals are in phase and the energy of the charge-transfer state is higher than the Frenkel state, the system exhibits J-aggregate characteristics including a positive band curvature, a red shifted main absorption peak, and an increase in the ratio of the first two vibronic peaks relative to the monomer. On the other hand, when the charge-transfer integrals are out of phase and the energy of the charge-transfer state is higher than the Frenkel state, the system exhibits H-aggregate characteristics including a negative band curvature, a blue shifted main absorption peak, and a decrease in the ratio of the first two vibronic peaks relative to the monomer. Notably, these signatures are consistent with those exhibited by Coulombically coupled J- and H-aggregates. Additional signatures of charge-transfer J- and H-aggregation are also discovered, the most notable of which is the appearance of a second absorption band when the charge-transfer integrals are in phase and the charge-transfer and Frenkel excitons are near resonance. In such instances, the peak-to-peak spacing is found to be proportional to the sum of the electron and hole transfer integrals. Further analysis of the charge-transfer interactions within the context of an effective Frenkel exciton coupling reveals that the charge-transfer interactions interfere directly with the intermolecular Coulombic coupling. The interference can be either constructive or destructive resulting in either enhanced or suppressed J- or H- aggregate behavior relative to what is expected based on Coulombic coupling alone. Such interferences result in four new aggregate types, namely HH-, HJ-, JH-, and JJ-aggregates, where the first letter indicates the nature of the Coulombic coupling and the second indicates the nature of the charge-transfer coupling. Vibronic signatures of such aggregates are developed and provide a means by which to rapidly screen materials for certain electronic characteristics. Notably, a large total (Coulombic plus charge-transfer) exciton coupling is associated with an absorption spectrum in which the ratio of the first two vibronic peaks deviates significantly from that of the unaggregated monomer. Hence, strongly coupled, high exciton mobility aggregates can be readily distinguished from low mobility aggregates by the ratio of their first two vibronic peaks. (Abstract shortened by ProQuest.).
Subotnik, Joseph E; Sodt, Alex; Head-Gordon, Martin
2008-01-21
Local coupled-cluster theory provides an algorithm for measuring electronic correlation quickly, using only the spatial locality of localized electronic orbitals. Previously, we showed [J. Subotnik et al., J. Chem. Phys. 125, 074116 (2006)] that one may construct a local coupled-cluster singles-doubles theory which (i) yields smooth potential energy surfaces and (ii) achieves near linear scaling. That theory selected which orbitals to correlate based only on the distances between the centers of different, localized orbitals, and the approximate potential energy surfaces were characterized as smooth using only visual identification. This paper now extends our previous algorithm in three important ways. First, locality is now based on both the distances between the centers of orbitals as well as the spatial extent of the orbitals. We find that, by accounting for the spatial extent of a delocalized orbital, one can account for electronic correlation in systems with some electronic delocalization using fast correlation methods designed around orbital locality. Second, we now enforce locality on not just the amplitudes (which measure the exact electron-electron correlation), but also on the two-electron integrals themselves (which measure the bare electron-electron interaction). Our conclusion is that we can bump integrals as well as amplitudes, thereby gaining a tremendous increase in speed and paradoxically increasing the accuracy of our LCCSD approach. Third and finally, we now make a rigorous definition of chemical smoothness as requiring that potential energy surfaces not support artificial maxima, minima, or inflection points. By looking at first and second derivatives from finite difference techniques, we demonstrate complete chemical smoothness of our potential energy surfaces (bumping both amplitudes and integrals). These results are significant both from a theoretical and from a computationally practical point of view.
Integrated control system for electron beam processes
NASA Astrophysics Data System (ADS)
Koleva, L.; Koleva, E.; Batchkova, I.; Mladenov, G.
2018-03-01
The ISO/IEC 62264 standard is widely used for integration of the business systems of a manufacturer with the corresponding manufacturing control systems based on hierarchical equipment models, functional data and manufacturing operations activity models. In order to achieve the integration of control systems, formal object communication models must be developed, together with manufacturing operations activity models, which coordinate the integration between different levels of control. In this article, the development of integrated control system for electron beam welding process is presented as part of a fully integrated control system of an electron beam plant, including also other additional processes: surface modification, electron beam evaporation, selective melting and electron beam diagnostics.
Chi, Qijin; Zhang, Jingdong; Arslan, Taner; Borg, Lotte; Pedersen, Gert W; Christensen, Hans E M; Nazmudtinov, Renat R; Ulstrup, Jens
2010-04-29
Intramolecular electron transfer (ET) between metal centers is a core feature of large protein complexes in photosynthesis, respiration, and redox enzyme catalysis. The number of microscopic redox potentials and ET rate constants is, however, prohibitive for experimental cooperative ET mapping, but two-center proteins are simple enough to offer complete communication networks. At the same time, multicenter redox proteins operate in membrane environments where conformational dynamics may lead to gated ET features different from conditions in homogeneous solution. The bacterial respiratory diheme protein Pseudomonas stutzeri cytochrome c(4) has been a target for intramolecular, interheme ET. We report here voltammetric and in situ scanning tunneling microscopy (STM) data for P. stutzeri cyt c(4) at single-crystal, atomically planar Au(111)-electrode surfaces modified by variable-length omega-mercapto-alkanoic carboxylic acids. As evidenced by in situ STM, the strongly dipolar protein is immobilized in a close to vertical orientation at this surface with the positively charged high-potential heme domain adjacent to the electrode. This orientation gives asymmetric voltammograms with two one-ET peaks in the cathodic direction and a single two-ET peak in the anodic direction. Intramolecular, interheme ET with high, 8,000-30,000 s(-1), rate constants is notably an essential part of this mechanism. The high rate constants are in striking contrast to ET reactions of P. stutzeri cyt c(4) with small reaction partners in homogeneous solution for which kinetic analysis clearly testifies to electrostatic cooperative effects but no intramolecular, interheme ET higher than 0.1-10 s(-1). This difference suggests a strong gating feature of the process. On the basis of the three-dimensional structure of P. stutzeri cyt c(4), gating is understandable due to the through-space, hydrogen-bonded electronic contact between the heme propionates which is highly sensitive to environmental configurational fluctuations.
Electron transmission through a class of anthracene aldehyde molecules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petreska, Irina, E-mail: irina.petreska@pmf.ukim.mk; Ohanesjan, Vladimir, E-mail: ohanesjan.vladimir@gmail.com; Pejov, Ljupco, E-mail: ljupcop@pmf.ukim.mk
2016-03-25
Transmission of electrons via metal-molecule-metal junctions, involving rotor-stator anthracene aldehyde molecules is investigated. Two model barriers having input parameters evaluated from accurate ab initio calculations are proposed and the transmission coefficients are obtained by using the quasiclassical approximation. Transmission coefficients further enter in the integral for the net current, utilizing Simmons’ method. Conformational dependence of the tunneling processes is evident and the presence of the side groups enhances the functionality of the future single-molecule based electronic devices.
Electron kinematics in a plasma focus
NASA Technical Reports Server (NTRS)
Hohl, F.; Gary, S. P.
1977-01-01
The results of numerical integrations of the three-dimensional relativistic equations of motion of electrons subject to given electric and magnetic fields are presented. Fields due to two different models are studied: (1) a circular distribution of current filaments, and (2) a uniform current distribution; both the collapse and the current reduction phases are studied in each model. Decreasing current in the uniform current model yields 100 keV electrons accelerated toward the anode and, as for earlier ion computations, provides general agreement with experimental results.
The effect of social integration on outcomes after major lower extremity amputation.
Hawkins, Alexander T; Pallangyo, Anthony J; Herman, Ayesiga M; Schaumeier, Maria J; Smith, Ann D; Hevelone, Nathanael D; Crandell, David M; Nguyen, Louis L
2016-01-01
Major lower extremity (MLE) amputation is a common procedure that results in a profound change in a patient's life. We sought to determine the association between social support and outcomes after amputation. We hypothesized that patients with greater social support will have better post amputation outcomes. From November 2011 to May 2013, we conducted a cross-sectional, observational, multicenter study. Social integration was measured by the social integration subset of the Short Form Craig Handicap Assessment and Reporting Technique. Systemic social support was assessed by comparing a United States and Tanzanian population. Walking function was measured using the 6-minute walk test and quality of life (QoL) was measured using the EuroQol-5D. We recruited 102 MLE amputees. Sixty-three patients were enrolled in the United States with a mean age of 58.0. Forty-two (67%) were male. Patients with low social integration were more likely to be unable to ambulate (no walk 39% vs slow walk 23% vs fast walk 10%; P = .01) and those with high social integration were more likely to be fast walkers (no walk 10% vs slow walk 59% vs fast walk 74%; P = .01). This relationship persisted in a multivariable analysis. Increasing social integration scores were also positively associated with increasing QoL scores in a multivariable analysis (β, .002; standard error, 0.0008; P = .02). In comparing the United States population with the Tanzanian cohort (39 subjects), there were no differences between functional or QoL outcomes in the systemic social support analysis. In the United States population, increased social integration is associated with both improved function and QoL outcomes among MLE amputees. Systemic social support, as measured by comparing the United States population with a Tanzanian population, was not associated with improved function or QoL outcomes. In the United States, steps should be taken to identify and aid amputees with poor social integration. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
The Effect of Social Integration on Outcomes after Major Lower Extremity Amputation
Hawkins, Alexander T.; Pallangyo, Anthony J.; Herman, Ayesiga M.; Schaumeier, Maria J.; Smith, Ann D.; Hevelone, Nathanael D.; Crandell, David M.; Nguyen, Louis
2016-01-01
Objective Major lower extremity amputation is a common procedure that results in a profound change in a patient's life. We sought to determine the association between social support and outcomes after amputation. We hypothesized that patients with greater social support will have better post amputation outcomes. Methods From November 2011 to May 2013, we conducted a cross-sectional, observational, multicenter study. Social integration was measured by the social integration subset of the Short Form (Craig Handicap Assessment and Reporting Technique (CHART). Systemic social support was assessed by comparing a US and Tanzanian population. Walking function was measured using the 6MWT and quality of life (QoL) was measured using the EQ-5D. Results 102 major lower extremity amputees were recruited. 63 patients were enrolled in the US with a mean age of 58.0. Forty-two (67%) were male. Patients with low social integration were more likely to be unable to ambulate (no walk 39% vs. slow walk 23% vs. fast walk 10%; P=.01) and those with high social integration were more likely to be fast walkers (no walk 10% vs. slow walk 59% vs. fast walk 74%; P=.01). This relationship persisted in a multivariable analysis. Increasing social integration scores were also positively associated with increasing quality of life scores in a multivariable analysis (β .002; SE .0008; P = .02). In comparing the US population with the Tanzanian cohort (39 subjects), there were no significant differences between functional or quality of life outcomes in the systemic social support analysis. Conclusions In the US population, increased social integration is associated with both improved function and quality of life outcomes among major lower extremity amputees. Systemic social support, as measured by comparing the US population with a Tanzanian population, was not associated with improved function or quality of life outcomes. In the US, steps should be taken to identify and aid amputees with poor social integration. PMID:26474508
Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, Shih-Wen; Tang, Kea-Tiong
2013-01-01
Electronic noses have potential applications in daily life, but are restricted by their bulky size and high price. This review focuses on the use of chemiresistive gas sensors, metal-oxide semiconductor gas sensors and conductive polymer gas sensors in an electronic nose for system integration to reduce size and cost. The review covers the system design considerations and the complementary metal-oxide-semiconductor integrated technology for a chemiresistive gas sensor electronic nose, including the integrated sensor array, its readout interface, and pattern recognition hardware. In addition, the state-of-the-art technology integrated in the electronic nose is also presented, such as the sensing front-end chip, electronic nose signal processing chip, and the electronic nose system-on-chip. PMID:24152879
The dynamical properties of a Rydberg hydrogen atom between two parallel metal surfaces
NASA Astrophysics Data System (ADS)
Liu, Wei; Li, Hong-Yun; Yang, Shan-Ying; Lin, Sheng-Lu
2011-03-01
This paper presents the dynamical properties of a Rydberg hydrogen atom between two metal surfaces using phase space analysis methods. The dynamical behaviour of the excited hydrogen atom depends sensitively on the atom—surface distance d. There exists a critical atom—surface distance dc = 1586 a.u. When the atom—surface distance d is larger than the critical distance dc, the image charge potential is less important than the Coulomb potential, the system is near-integrable and the electron motion is regular. As the distance d decreases, the system will tend to be non-integrable and unstable, and the electron might be captured by the metal surfaces. Project supported by the National Natural Science Foundation of China (Grant No. 10774093) and the Natural Science Foundation of Shandong Province (Grant No. ZR2009FZ006).
NASA Technical Reports Server (NTRS)
Clapp, L. H.; Twiss, R. G.; Cattolica, R. J.
1991-01-01
Experimental results are presented related to the radial spread of fluorescence excited by 10 and 20 KeV electron beams passing through nonflowing rarefied nitrogen at 293 K. An imaging technique for obtaining species distributions from measured beam-excited fluorescence is described, based on a signal inversion scheme mathematically equivalent to the inversion of the Abel integral equation. From fluorescence image data, measurements of beam radius, integrated signal intensity, and spatially resolved distributions of N2(+) first-negative-band fluorescence-emitting species have been made. Data are compared with earlier measurements and with an heuristic beam spread model.
Long anterior zonules and pigment dispersion.
Moroi, Sayoko E; Lark, Kurt K; Sieving, Paul A; Nouri-Mahdavi, Kouros; Schlötzer-Schrehardt, Ursula; Katz, Gregory J; Ritch, Robert
2003-12-01
To describe pigment dispersion associated with long anterior zonules. Multicenter observational case series. Fifteen patients, seven of whom were treated for glaucoma or ocular hypertension, were identified with long anterior zonules and pigment dispersion. Transmission electron microscopy was performed on one anterior capsule specimen. All patients had anterior zonules that inserted centrally on the lens capsule. Signs of pigment dispersion included corneal endothelial pigmentation, loss of the pupillary ruff, and variable trabecular meshwork pigmentation. Ultrasound biomicroscopy verified the lack of posterior iris insertion and concavity. There was no exfoliation material. Transmission electron microscopy showed zonular lamellae with adherent pigment granules, and no exfoliation material. Long anterior zonules inserted onto the central lens capsule may cause mechanical disruption of the pigment epithelium at the pupillary ruff and central iris leading to pigment dispersion.
Koo, Ja Hoon; Jeong, Seongjin; Shim, Hyung Joon; Son, Donghee; Kim, Jaemin; Kim, Dong Chan; Choi, Suji; Hong, Jong-In; Kim, Dae-Hyeong
2017-10-24
With the rapid advances in wearable electronics, the research on carbon-based and/or organic materials and devices has become increasingly important, owing to their advantages in terms of cost, weight, and mechanical deformability. Here, we report an effective material and device design for an integrative wearable cardiac monitor based on carbon nanotube (CNT) electronics and voltage-dependent color-tunable organic light-emitting diodes (CTOLEDs). A p-MOS inverter based on four CNT transistors allows high amplification and thereby successful acquisition of the electrocardiogram (ECG) signals. In the CTOLEDs, an ultrathin exciton block layer of bis[2-(diphenylphosphino)phenyl]ether oxide is used to manipulate the balance of charges between two adjacent emission layers, bis[2-(4,6-difluorophenyl)pyridinato-C 2 ,N](picolinato)iridium(III) and bis(2-phenylquinolyl-N,C(2'))iridium(acetylacetonate), which thereby produces different colors with respect to applied voltages. The ultrathin nature of the fabricated devices supports extreme wearability and conformal integration of the sensor on human skin. The wearable CTOLEDs integrated with CNT electronics are used to display human ECG changes in real-time using tunable colors. These materials and device strategies provide opportunities for next generation wearable health indicators.
Harle, Christopher A; Listhaus, Alyson; Covarrubias, Constanza M; Schmidt, Siegfried Of; Mackey, Sean; Carek, Peter J; Fillingim, Roger B; Hurley, Robert W
2016-01-01
In this case report, the authors describe the implementation of a system for collecting patient-reported outcomes and integrating results in an electronic health record. The objective was to identify lessons learned in overcoming barriers to collecting and integrating patient-reported outcomes in an electronic health record. The authors analyzed qualitative data in 42 documents collected from system development meetings, written feedback from users, and clinical observations with practice staff, providers, and patients. Guided by the Unified Theory on the Adoption and Use of Information Technology, 5 emergent themes were identified. Two barriers emerged: (i) uncertain clinical benefit and (ii) time, work flow, and effort constraints. Three facilitators emerged: (iii) process automation, (iv) usable system interfaces, and (v) collecting patient-reported outcomes for the right patient at the right time. For electronic health record-integrated patient-reported outcomes to succeed as useful clinical tools, system designers must ensure the clinical relevance of the information being collected while minimizing provider, staff, and patient burden. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutter, P., E-mail: psutter@bnl.gov; Sutter, E.
2014-09-01
We assess scanning electron microscopy (SEM) and Auger electron spectroscopy (AES) for thickness measurements on few-layer hexagonal boron nitride (h-BN), the layered dielectric of choice for integration with graphene and other two-dimensional materials. Observations on h-BN islands with large, atomically flat terraces show that the secondary electron intensity in SEM reflects monolayer height changes in films up to least 10 atomic layers thickness. From a quantitative analysis of AES data, the energy-dependent electron escape depth in h-BN films is deduced. The results show that AES is suitable for absolute thickness measurements of few-layer h-BN of 1 to 6 layers.
Factors predicting survival in ALS: a multicenter Italian study.
Calvo, Andrea; Moglia, Cristina; Lunetta, Christian; Marinou, Kalliopi; Ticozzi, Nicola; Ferrante, Gianluca Drago; Scialo, Carlo; Sorarù, Gianni; Trojsi, Francesca; Conte, Amelia; Falzone, Yuri M; Tortelli, Rosanna; Russo, Massimo; Chiò, Adriano; Sansone, Valeria Ada; Mora, Gabriele; Silani, Vincenzo; Volanti, Paolo; Caponnetto, Claudia; Querin, Giorgia; Monsurrò, Maria Rosaria; Sabatelli, Mario; Riva, Nilo; Logroscino, Giancarlo; Messina, Sonia; Fini, Nicola; Mandrioli, Jessica
2017-01-01
The aim of this multicenter, retrospective study is to investigate the role of clinical characteristics and therapeutic intervention on ALS prognosis. The study included patients diagnosed from January 1, 2009 to December 31, 2013 in 13 Italian referral centers for ALS located in 10 Italian regions. Caring neurologists collected a detailed phenotypic profile and follow-up data until death into an electronic database. One center collected also data from a population-based registry for ALS. 2648 incident cases were collected. The median survival time from onset to death/tracheostomy was 44 months (SE 1.18, CI 42-46). According to univariate analysis, factors related to survival from onset to death/tracheostomy were: age at onset, diagnostic delay, site of onset, phenotype, degree of certainty at diagnosis according to revised El Escorial criteria (R-EEC), presence/absence of dementia, BMI at diagnosis, patients' provenance. In the multivariate analysis, age at onset, diagnostic delay, phenotypes but not site of onset, presence/absence of dementia, BMI, riluzole use, R-EEC criteria were independent prognostic factors of survival in ALS. We compared patients from an ALS Registry with patients from tertiary centers; the latter ones were younger, less frequently bulbar, but more frequently familial and definite at diagnosis. Our large, multicenter study demonstrated the role of some clinical and demographic factors on ALS survival, and showed some interesting differences between referral centers' patients and the general ALS population. These results can be helpful for clinical practice, in clinical trial design and to validate new tools to predict disease progression.
Universality of Electron Distributions in Extensive Air Showers
NASA Astrophysics Data System (ADS)
Śmiałkowski, Andrzej; Giller, Maria
2018-02-01
Based on extensive air shower simulations, it is shown that electron distributions with respect to two angles determining the electron direction at a given shower age, for a fixed electron energy and lateral distance, are universal. This means that the distributions do not depend on the primary particle energy or mass (thus, neither on the interaction model), shower zenith angle, or shower to shower fluctuations, if they are taken at the same shower age. Together with previous work showing the universality of the distributions of the electron energy, lateral distance (integrated over angles), and angle (integrated over lateral distance) for fixed electron energy, this paper completes a full universal description of the electron states at various shower ages. Analytical parametrizations of the full electron states are given. It is also shown that some distributions can be described by a number of variables smaller than five, with the new ones being products of old ones raised to some power. The accuracy of the present parametrization is sufficiently good to apply to showers with a primary energy uncertainty of 14% (as is the case at the Pierre Auger Observatory). The shower fluctuations in the chosen bins of the multidimensional variable space are about 6%, determining the minimum uncertainty needed for the parametrization of the universal distributions. An analytical way of estimating the effect of the geomagnetic field is given. Thanks to the universality of the electron distribution in any shower, a new method of shower reconstruction can be worked out from the data from observatories using the fluorescence technique. The light fluxes (both fluorescence and Cherenkov) for any shower age can be exactly predicted for a shower with any primary energy and shower maximum depth, so that the two quantities can be obtained by best fitting the predictions to the measurements.
International Survey on the Management of Wake-Up Stroke.
de Castro-Afonso, Luís Henrique; Nakiri, Guilherme Seizem; Pontes-Neto, Octávio Marques; dos Santos, Antônio Carlos; Abud, Daniel Giansante
2016-01-01
Patients who wake up having experienced a stroke while asleep represent around 20% of acute stroke admissions. According to international guidelines for the management of acute stroke, patients presenting with wake-up stroke are not currently eligible to receive revascularization treatments. In this study, we aimed to assess the opinions of stroke experts about the management of patients with wake-up stroke by using an international multicenter electronic survey. This study consisted of 8 questions on wake-up stroke treatment. Two hundred invitations to participate in the survey were sent by e-mail. Fifty-nine participants started the survey, 4 dropped out before completing it, and 55 completed the full questionnaire. We had 55 participants from 22 countries. In this study, most stroke experts recommended a recanalization treatment for wake-up stroke. However, there was considerable disagreement among experts regarding the best brain imaging method and the best recanalization treatment. The results of ongoing randomized trials on wake-up stroke are urgently needed.
Inner-shell radiation from wire array implosions on the Zebra generator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouart, N. D.; Giuliani, J. L.; Dasgupta, A.
2014-03-15
Implosions of brass wire arrays on Zebra have produced L-shell radiation as well as inner-shell Kα and Kβ transitions. The L-shell radiation comes from ionization stages around the Ne-like charge state that is largely populated by a thermal electron energy distribution function, while the K-shell photons are a result of high-energy electrons ionizing or exciting an inner-shell (1s) electron from ionization stages around Ne-like. The K- and L-shell radiations were captured using two time-gated and two axially resolved time-integrated spectrometers. The electron beam was measured using a Faraday cup. A multi-zone non-local thermodynamic equilibrium pinch model with radiation transport ismore » used to model the x-ray emission from experiments for the purpose of obtaining plasma conditions. These plasma conditions are used to discuss some properties of the electron beam generated by runaway electrons. A simple model for runaway electrons is examined to produce the Kα radiation, but it is found to be insufficient.« less
Modelling relativistic effects in momentum-resolved electron energy loss spectroscopy of graphene
NASA Astrophysics Data System (ADS)
Lyon, K.; Mowbray, D. J.; Miskovic, Z. L.
2018-02-01
We present an analytical model for the electron energy loss through a two-dimensional (2D) layer of graphene, fully taking into account relativistic effects. Using two different models for graphene's 2D conductivity, one a two-fluid hydrodynamic model with an added correction to account for the inter-band electron transitions near the Dirac point in undoped graphene, the other derived from ab initio plane-wave time-dependent density functional theory in the frequency domain (PW-TDDFT-ω) calculations applied on a graphene superlattice, we derive various different expressions for the probability density of energy and momentum transfer from the incident electron to graphene. To further compare with electron energy loss spectroscopy (EELS) experiments that use setups like scanning Transmission Electron Microscopy, we integrated our energy loss functions over a range of wavenumbers, and compared how the choice of range directly affects the shape, position, and relative heights of graphene's π → π* and σ → σ* transition peaks. Comparisons were made with experimental EELS data under different model inputs, revealing again the strong effect that the choice of wavenumber range has on the energy loss.
ERIC Educational Resources Information Center
Scott-Bracey, Pamela
2011-01-01
The purpose of this study was to explore the alignment of soft skills sought by current business IS entry-level employers in electronic job postings, with the integration of soft skills in undergraduate business information systems (IS) syllabi of public four-year universities in Texas. One hundred fifty job postings were extracted from two major…
Van Leusden, H A; Albertyn, G; Verlaine, C; Van Ruymbeke, J
1993-01-01
Comparison of the effects of treatment of two transdermal therapeutic systems for estrogen replacement therapy with regard to efficacy, tolerability, and acceptance. Open randomized. Multicenter. A study population of 104 postmenopausal women was randomized on a 1:1 basis to treatment with one of two estradiol patches, System (Cilag) and Estraderm (Ciba-Geigy). Systolic and diastolic BP, hot flushes, night sweating, fatigue, insomnia, depression, nervousness, headache, vaginal discomfort (efficacy variables); bleeding, dermatological symptoms, comfort and adhesiveness of patch, and other possible causes of discontinuation (tolerability); general evaluation by patient (acceptance). Considering all efficacy variables, 53% of Systen and 46% of Estraderm patients found the therapy satisfactory. Tolerability was somewhat higher in the Systen group. Adhesiveness of the patch was significantly better for Systen. Overall, 79% of Systen patients and 62% of Estraderm patients evaluated treatment as "good" or "very good." The majority of patients in both groups found the patch very comfortable or only slightly obtrusive.
McDermott, D J; Agre, K; Brim, M; Demma, F J; Nelson, J; Wilson, R R; Thisted, R A
1985-04-01
To extent the safety information for Chymodiactin (chymopapain for injection), 37 neurologic and orthopedic surgeons conducted an open-label, multicenter, phase 3 clinical study. A total of 1,498 patients with one or two herniated lumbar intervertebral discs were enrolled. Therapeutic results were generally favorable, with the percentages of patients achieving either excellent or good (or successful) results ranging from 79.6% to 88.9%, depending on criteria employed in the tabulation. There were 13 cases of anaphylaxis, and 2 of these patients died of complications of anaphylaxis. Two additional patients experienced serious neurologic problems. The first of these two patients developed transverse myelitis and paraplegia approximately 3 weeks following chemonucleolysis. Transdural discograms at three levels had been done approximately 2 days prior to chemonucleolysis, in violation of the protocol. The second patient developed acute cauda equina syndrome, and, despite emergency laminectomy, had permanent neurologic sequelae. Back spasm and stiffness/soreness were the most frequently encountered adverse experiences.
Patterson, Charles W
2012-06-01
In multicenter service organizations, managers often make centralized decisions without considering the effects of differing production characteristics and influential factors on each center. In this study, the author examines differences in production characteristics and factors that influence production, as well as their likely effect on policy formulation, in a large, six-center dental group in the Chicago area. The results of the study show that the six centers (in two groups) exhibited two distinct production patterns, with three having logarithmic distributions and three having normal distributions. Production differences between the groups likely resulted from differences in managed care, staffing and dental procedures performed. Instead of being monolithic, the organization exhibited two types of centers, each with its own production characteristics and factors that influenced production. The study results suggest that large service corporations and }partnerships would benefit from conducting analyses of production characteristics and factors that influence production before making policy decisions that affect the entire organization.
Protection of the electronic components of measuring equipment from the X-ray radiation
NASA Astrophysics Data System (ADS)
Perez Vasquez, N. O.; Kostrin, D. K.; Uhov, A. A.
2018-02-01
In this work the effect of X-ray radiation on the operation of integrated circuits of the measurement equipment is discussed. The results of the calculations of a shielding system, allowing using integrated circuits with a high degree of integration in the vicinity of the X-ray source, are shown. The results of the verification of two measurement devices that was used for more than five years in the facility for training and testing of X-ray tubes are presented.
NASA Astrophysics Data System (ADS)
Somogyi, Gábor; Trócsányi, Zoltán
2008-08-01
In previous articles we outlined a subtraction scheme for regularizing doubly-real emission and real-virtual emission in next-to-next-to-leading order (NNLO) calculations of jet cross sections in electron-positron annihilation. In order to find the NNLO correction these subtraction terms have to be integrated over the factorized unresolved phase space and combined with the two-loop corrections. In this paper we perform the integration of all one-parton unresolved subtraction terms.
Vertical and Lateral Electron Content in the Martian Ionosphere
NASA Astrophysics Data System (ADS)
Paetzold, M. P.; Peter, K.; Bird, M. K.; Häusler, B.; Tellmann, S.
2016-12-01
The radio-science experiment MaRS (Mars Express Radio Science) on the Mars Express spacecraft sounds the neutral atmosphere and ionosphere of Mars since 2004. Approximately 800 vertical profiles of the ionospheric electron density have been acquired until today. The vertical electron content (TEC) is easily computed from the vertical electron density profile by integrating along the altitude. The TEC is typically a fraction of a TEC unit (1E16 m^-2) and depends on the solar zenith angle. The magnitude of the TEC is however fully dominated by the electron density contained in the main layer M2. The contributions by the M1 layer below M2 or the topside is marginal. MaRS is using two radio frequencies for the sounding of the ionosphere. The directly observed differential Doppler from the two received frequencies is a measure of the lateral electron content that means along the ray path and perpendicular to the vertical electron density profile. Combining both the vertical electron density profile, the vertical TEC and the directly observed lateral TEC describes the lateral electron density distribution in the ionosphere.
Burns, Kristin M.; Pemberton, Victoria L.; Pearson, Gail D.
2017-01-01
Purpose of review Because of the relatively small numbers of pediatric patients with congenital heart disease cared for in any individual center, there is a significant need for multicenter clinical studies to validate new medical or surgical therapies. The Pediatric Heart Network (PHN), with 15 years of experience in multicenter clinical research, has tackled numerous challenges when conducting multicenter studies. Recent findings This review describes the challenges encountered and the strategies employed to conduct high-quality, collaborative research in pediatric cardiovascular disease. Summary Sharing lessons learned from the PHN can provide guidance to investigators interested in conducting pediatric multicenter studies. PMID:26196261
Stabilini, Cesare; Bracale, Umberto; Pignata, Giusto; Frascio, Marco; Casaccia, Marco; Pelosi, Paolo; Signori, Alessio; Testa, Tommaso; Rosa, Gian Marco; Morelli, Nicola; Fornaro, Rosario; Palombo, Denise; Perotti, Serena; Bruno, Maria Santina; Imperatore, Mikaela; Righetti, Carolina; Pezzato, Stefano; Lazzara, Fabrizio; Gianetta, Ezio
2013-10-28
Re-approximation of the rectal muscles along the midline is recommended by some groups as a rule for incisional and ventral hernia repairs. The introduction of laparoscopic repair has generated a debate because it is not aimed at restoring abdominal wall integrity but instead aims just to bridge the defect. Whether restoration of the abdominal integrity has a real impact on patient mobility is questionable, and the available literature provides no definitive answer. The present study aims to compare the functional results of laparoscopic bridging with those of re-approximation of the rectal muscle in the midline as a mesh repair for ventral and incisional abdominal defect through an "open" access. We hypothesized that, for the type of defect suitable for a laparoscopic bridging, the effect of an anatomical reconstruction is near negligible, thus not a fixed rule. The LABOR trial is a multicenter, prospective, two-arm, single-blinded, randomized trial. Patients of more than 60 years of age with a defect of less than 10 cm at its greatest diameter will be randomly submitted to open Rives or laparoscopic defect repair. All the participating patients will have a preoperative evaluation of their abdominal wall strength and mobility along with volumetry, respiratory function test, intraabdominal pressure and quality of life assessment.The primary outcome will be the difference in abdominal wall strength as measured by a double leg-lowering test performed at 12 months postoperatively. The secondary outcomes will be the rate of recurrence and changes in baseline abdominal mobility, respiratory function tests, intraabdominal pressure, CT volumetry and quality of life at 6 and 12 months postoperatively. The study will help to define the most suitable treatment for small-medium incisional and primary hernias in patients older than 60 years. Given a similar mid-term recurrence rate in both groups, if the trial shows no differences among treatments (acceptance of the null-hypothesis), then the choice of whether to submit a patient to one intervention will be made on the basis of cost and the surgeon's experience. Current Controlled Trials ISRCTN93729016.
Nozue, Tsuyoshi; Fukui, Kazuki; Koyama, Yutaka; Fujii, Hiroyuki; Kunishima, Tomoyuki; Hikita, Hiroyuki; Hibi, Kiyoshi; Miyazawa, Akiyoshi; Michishita, Ichiro
2016-05-01
Patients with diabetes mellitus are at high risk for developing coronary artery disease (CAD), even if they are treated with statins. Several studies have shown the beneficial effects of dipeptidyl peptidase-4 (DPP-4) inhibitors on the cardiovascular system in an animal model. However, recent clinical trials using DPP-4 inhibitors have shown that these inhibitors fail to reduce the occurrence of cardiovascular events. Therefore, this study will be performed to evaluate the effects of sitagliptin, a DPP-4 inhibitor, on coronary atherosclerosis in patients with type 2 diabetes. This study will be a prospective, open-label, randomized multicenter trial performed in 6 centers in Japan. Stable CAD patients with type 2 diabetes who have undergone successful percutaneous coronary intervention under integrated backscatter (IB)-intravascular ultrasound (IVUS) guidance will be studied. They will be randomly assigned to either the sitagliptin group or a control group. After 48 weeks' treatment, the IVUS examination will be repeated in the same coronary artery as at baseline. The primary end point will be the percentage change in plaque volume measured using grayscale IVUS from baseline to the 48-week follow-up. This study will be the first multicenter trial to evaluate the effects of a DPP-4 inhibitor on coronary atherosclerosis evaluated using IB-IVUS, and the findings will clarify the anti-atherogenic effects of sitagliptin.
Stretchable electronics for wearable and high-current applications
NASA Astrophysics Data System (ADS)
Hilbich, Daniel; Shannon, Lesley; Gray, Bonnie L.
2016-04-01
Advances in the development of novel materials and fabrication processes are resulting in an increased number of flexible and stretchable electronics applications. This evolving technology enables new devices that are not readily fabricated using traditional silicon processes, and has the potential to transform many industries, including personalized healthcare, consumer electronics, and communication. Fabrication of stretchable devices is typically achieved through the use of stretchable polymer-based conductors, or more rigid conductors, such as metals, with patterned geometries that can accommodate stretching. Although the application space for stretchable electronics is extensive, the practicality of these devices can be severely limited by power consumption and cost. Moreover, strict process flows can impede innovation that would otherwise enable new applications. In an effort to overcome these impediments, we present two modified approaches and applications based on a newly developed process for stretchable and flexible electronics fabrication. This includes the development of a metallization pattern stamping process allowing for 1) stretchable interconnects to be directly integrated with stretchable/wearable fabrics, and 2) a process variation enabling aligned multi-layer devices with integrated ferromagnetic nanocomposite polymer components enabling a fully-flexible electromagnetic microactuator for large-magnitude magnetic field generation. The wearable interconnects are measured, showing high conductivity, and can accommodate over 20% strain before experiencing conductive failure. The electromagnetic actuators have been fabricated and initial measurements show well-aligned, highly conductive, isolated metal layers. These two applications demonstrate the versatility of the newly developed process and suggest potential for its furthered use in stretchable electronics and MEMS applications.
Zhu, Weida; Wang, Rui; Zhang, Chunfeng; Wang, Guodong; Liu, Yunlong; Zhao, Wei; Dai, Xingcan; Wang, Xiaoyong; Cerullo, Giulio; Cundiff, Steven; Xiao, Min
2017-09-04
We introduce a novel configuration for two-dimensional electronic spectroscopy (2DES) that combines the partially collinear pump-probe geometry with active phase locking. We demonstrate the method on a solution sample of CdSe/ZnS nanocrystals by employing two non-collinear optical parametric amplifiers as the pump and probe sources. The two collinear pump pulse replicas are created using a Mach-Zehnder interferometer phase stabilized by active feedback electronics. Taking the advantage of separated paths of the two pump pulses in the interferometer, we improve the signal-to-noise ratio with double modulation of the individual pump beams. In addition, a quartz wedge pair manipulates the phase difference between the two pump pulses, enabling the recovery of the rephasing and non-rephasing signals. Our setup integrates many advantages of available 2DES techniques with robust phase stabilization, ultrafast time resolution, two-color operation, long delay scan, individual polarization manipulation and the ease of implementation.
Hammoud, Maya M; Margo, Katherine; Christner, Jennifer G; Fisher, Jonathan; Fischer, Shira H; Pangaro, Louis N
2012-01-01
Few studies have reported on the utilization and the effect of electronic health records on the education of medical students. The purpose of this study was to describe the current use of electronic health records by medical students in the United States and explore the opportunities and challenges of integrating electronic health records into daily teaching of medical students. A survey with 24 questions regarding the use of electronic health records by medical students was developed by the Alliance for Clinical Educators and sent to clerkship directors across the United States. Both quantitative and qualitative responses were collected and analyzed to determine current access to and use of electronic health records by medical students. This study found that an estimated 64% of programs currently allow student use of electronic health records, of which only two thirds allowed students to write notes within the electronic record. Overall, clerkship directors' opinions on the effects of electronic health records on medical student education were neutral, and despite acknowledging many advantages to electronic health records, there were many concerns raised regarding their use in education. Medical students are using electronic health records at higher rates than physicians in practice. Although this is overall reassuring, educators have to be cautious about the limitations being placed on student's documentation in electronic health records as this can potentially have consequences on their training, and they need to explore ways to maximize the benefits of electronic health records in medical education.
Kovaleva, Lidia; Apte, Shashikant; Damodar, Sharat; Ramanan, Vijay; Loriya, Svetlana; Navarro-Puerto, Jordi; Khojasteh, Ali
2016-12-01
To assess safety and efficacy of a 10% intravenous immunoglobulin in patients with primary immune thrombocytopenic purpura (ITP). ITP patients in two multicenter studies (Trials A/B) were treated with 2 g/kg Flebogamma ® 10% DIF (over 2-5 days) and were followed up to 1-3 months. 18 patients in Trial A and 58 in Trial B were enrolled (12 children in Trial B). The response rate (platelet count ≥50 × 10 9 /l) was 72.2% (Trial A) and 76.1/100% (adults/children; Trial B). Most patients improved bleedings (83.3% Trial A; 88.9% Trial B). Potential treatment-related adverse events were reported by 38.9% (Trial A) and 30.4/83.3% (adults/children; Trial B) of patients. All serious adverse events (five patients) resolved without sequelae. Flebogamma 10% DIF was effective and safe in patients with primary ITP.
An analytical method for computing voxel S values for electrons and photons.
Amato, Ernesto; Minutoli, Fabio; Pacilio, Massimiliano; Campenni, Alfredo; Baldari, Sergio
2012-11-01
The use of voxel S values (VSVs) is perhaps the most common approach to radiation dosimetry for nonuniform distributions of activity within organs or tumors. However, VSVs are currently available only for a limited number of voxel sizes and radionuclides. The objective of this study was to develop a general method to evaluate them for any spectrum of electrons and photons in any cubic voxel dimension of practical interest for clinical dosimetry in targeted radionuclide therapy. The authors developed a Monte Carlo simulation in Geant4 in order to evaluate the energy deposited per disintegration (E(dep)) in a voxelized region of soft tissue from monoenergetic electrons (10-2000 keV) or photons (10-1000 keV) homogeneously distributed in the central voxel, considering voxel dimensions ranging from 3 mm to 10 mm. E(dep) was represented as a function of a dimensionless quantity termed the "normalized radius," R(n) = R∕l, where l is the voxel size and R is the distance from the origin. The authors introduced two parametric functions in order to fit the electron and photon results, and they interpolated the parameters to derive VSVs for any energy and voxel side within the ranges mentioned above. In order to validate the results, the authors determined VSV for two radionuclides ((131)I and (89)Sr) and two voxel dimensions and they compared them with reference data. A validation study in a simple sphere model, accounting for tissue inhomogeneities, is presented. The E(dep)(R(n)) for both monoenergetic electrons and photons exhibit a smooth variation with energy and voxel size, implying that VSVs for monoenergetic electrons or photons may be derived by interpolation over the range of energies and dimensions considered. By integration, S values for continuous emission spectra from β(-) decay may be derived as well. The approach allows the determination of VSVs for monoenergetic (Auger or conversion) electrons and (x-ray or gamma-ray) photons by means of two functions whose parameters can be interpolated from tabular data provided. Through integration, it is possible to generalize the method to any continuous (beta) spectrum, allowing to calculate VSVs for any electron and photon emitter in a voxelized structure.
Youngerman, Brett E; Salmasian, Hojjat; Carter, Eileen J; Loftus, Michael L; Perotte, Rimma; Ross, Barbara G; Furuya, E Yoko; Green, Robert A; Vawdrey, David K
2018-06-13
To integrate electronic clinical decision support tools into clinical practice and to evaluate the impact on indwelling urinary catheter (IUC) use and catheter-associated urinary tract infections (CAUTIs).Design, Setting, and ParticipantsThis 4-phase observational study included all inpatients at a multicampus, academic medical center between 2011 and 2015.InterventionsPhase 1 comprised best practices training and standardization of electronic documentation. Phase 2 comprised real-time electronic tracking of IUC duration. In phase 3, a triggered alert reminded clinicians of IUC duration. In phase 4, a new IUC order (1) introduced automated order expiration and (2) required consideration of alternatives and selection of an appropriate indication. Overall, 2,121 CAUTIs, 179,070 new catheters, 643,055 catheter days, and 2,186 reinsertions occurred in 3·85 million hospitalized patient days during the study period. The CAUTI rate per 10,000 patient days decreased incrementally in each phase from 9·06 in phase 1 to 1·65 in phase 4 (relative risk [RR], 0·182; 95% confidence interval [CI], 0·153-0·216; P<·001). New catheters per 1,000 patient days declined from 53·4 in phase 1 to 39·5 in phase 4 (RR, 0·740; 95% CI, 0·730; P<·001), and catheter days per 1,000 patient days decreased from 194·5 in phase 1 to 140·7 in phase 4 (RR, 0·723; 95% CI, 0·719-0·728; P<·001). The reinsertion rate declined from 3·66% in phase 1 to 3·25% in phase 4 (RR, 0·894; 95% CI, 0·834-0·959; P=·0017). The phased introduction of decision support tools was associated with progressive declines in new catheters, total catheter days, and CAUTIs. Clinical decision support tools offer a viable and scalable intervention to target hospital-wide IUC use and hold promise for other quality improvement initiatives.
Self-assembly of electronically abrupt borophene/organic lateral heterostructures
Liu, Xiaolong; Wei, Zonghui; Balla, Itamar; Mannix, Andrew J.; Guisinger, Nathan P.; Luijten, Erik; Hersam, Mark C.
2017-01-01
Two-dimensional boron sheets (that is, borophene) have recently been realized experimentally and found to have promising electronic properties. Because electronic devices and systems require the integration of multiple materials with well-defined interfaces, it is of high interest to identify chemical methods for forming atomically abrupt heterostructures between borophene and electronically distinct materials. Toward this end, we demonstrate the self-assembly of lateral heterostructures between borophene and perylene-3,4,9,10-tetracarboxylic dianhydride (PTCDA). These lateral heterostructures spontaneously form upon deposition of PTCDA onto submonolayer borophene on Ag(111) substrates as a result of the higher adsorption enthalpy of PTCDA on Ag(111) and lateral hydrogen bonding among PTCDA molecules, as demonstrated by molecular dynamics simulations. In situ x-ray photoelectron spectroscopy confirms the weak chemical interaction between borophene and PTCDA, while molecular-resolution ultrahigh-vacuum scanning tunneling microscopy and spectroscopy reveal an electronically abrupt interface at the borophene/PTCDA lateral heterostructure interface. As the first demonstration of a borophene-based heterostructure, this work will inform emerging efforts to integrate borophene into nanoelectronic applications. PMID:28261662
Test-retest and between-site reliability in a multicenter fMRI study.
Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G
2008-08-01
In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.
Bove, Riley; Chitnis, Tanuja; Cree, Bruce Ac; Tintoré, Mar; Naegelin, Yvonne; Uitdehaag, Bernard Mj; Kappos, Ludwig; Khoury, Samia J; Montalban, Xavier; Hauser, Stephen L; Weiner, Howard L
2017-08-01
There is a pressing need for robust longitudinal cohort studies in the modern treatment era of multiple sclerosis. Build a multiple sclerosis (MS) cohort repository to capture the variability of disability accumulation, as well as provide the depth of characterization (clinical, radiologic, genetic, biospecimens) required to adequately model and ultimately predict a patient's course. Serially Unified Multicenter Multiple Sclerosis Investigation (SUMMIT) is an international multi-center, prospectively enrolled cohort with over a decade of comprehensive follow-up on more than 1000 patients from two large North American academic MS Centers (Brigham and Women's Hospital (Comprehensive Longitudinal Investigation of Multiple Sclerosis at the Brigham and Women's Hospital (CLIMB; BWH)) and University of California, San Francisco (Expression/genomics, Proteomics, Imaging, and Clinical (EPIC))). It is bringing online more than 2500 patients from additional international MS Centers (Basel (Universitätsspital Basel (UHB)), VU University Medical Center MS Center Amsterdam (MSCA), Multiple Sclerosis Center of Catalonia-Vall d'Hebron Hospital (Barcelona clinically isolated syndrome (CIS) cohort), and American University of Beirut Medical Center (AUBMC-Multiple Sclerosis Interdisciplinary Research (AMIR)). We provide evidence for harmonization of two of the initial cohorts in terms of the characterization of demographics, disease, and treatment-related variables; demonstrate several proof-of-principle analyses examining genetic and radiologic predictors of disease progression; and discuss the steps involved in expanding SUMMIT into a repository accessible to the broader scientific community.
Villar, Jesús; Pérez-Méndez, Lina; Blanco, Jesús; Añón, José Manuel; Blanch, Lluís; Belda, Javier; Santos-Bouza, Antonio; Fernández, Rosa Lidia; Kacmarek, Robert M
2013-04-01
The PaO2/FiO2 is an integral part of the assessment of patients with acute respiratory distress syndrome (ARDS). The American-European Consensus Conference definition does not mandate any standardization procedure. We hypothesized that the use of PaO2/FiO2 calculated under a standard ventilatory setting within 24 h of ARDS diagnosis allows a more clinically relevant ARDS classification. We studied 452 ARDS patients enrolled prospectively in two independent, multicenter cohorts treated with protective mechanical ventilation. At the time of ARDS diagnosis, patients had a PaO2/FiO2 ≤ 200. In the derivation cohort (n = 170), we measured PaO2/FiO2 with two levels of positive end-expiratory pressure (PEEP) (≥ 5 and ≥ 10 cmH2O) and two levels of FiO2 (≥ 0.5 and 1.0) at ARDS onset and 24 h later. Dependent upon PaO2 response, patients were reclassified into three groups: mild (PaO2/FiO2 > 200), moderate (PaO2/FiO2 101-200), and severe (PaO2/FiO2 ≤ 100) ARDS. The primary outcome measure was ICU mortality. The standard ventilatory setting that reached the highest significance difference in mortality among these categories was tested in a separate cohort (n = 282). The only standard ventilatory setting that identified the three PaO2/FiO2 risk categories in the derivation cohort was PEEP ≥ 10 cmH2O and FiO2 ≥ 0.5 at 24 h after ARDS onset (p = 0.0001). Using this ventilatory setting, patients in the validation cohort were reclassified as having mild ARDS (n = 47, mortality 17 %), moderate ARDS (n = 149, mortality 40.9 %), and severe ARDS (n = 86, mortality 58.1 %) (p = 0.00001). Our method for assessing PaO2/FiO2 greatly improved risk stratification of ARDS and could be used for enrolling appropriate ARDS patients into therapeutic clinical trials.
Tomoda, Takeshi; Kato, Hironari; Mizukawa, Sho; Muro, Shinichiro; Akimoto, Yutaka; Uchida, Daisuke; Matsumoto, Kazuyuki; Yamamoto, Naoki; Horiguchi, Shigeru; Tsutsumi, Koichiro; Okada, Hiroyuki
2016-01-01
Acute pancreatitis is the major complication of endoscopic retrograde cholangiopancreatography (ERCP). A preliminary research suggested that the administration of nonsteroidal anti-inflammatory drugs (NSAIDs) with nitroglycerin might reduce the incidence of post-ERCP pancreatitis (PEP) more effectively than NSAIDs alone. We conduct a two-arm, multicenter, prospective, randomized, superiority trial to evaluate the additional effect of nitroglycerin for prevention of PEP. A total of 900 patients randomly receive 50 mg diclofenac suppository either alone or with 5 mg isosorbide dinitrate sublingual tablet. The primary endpoint is the occurrence of PEP. This study will clarify whether NSAIDs plus nitroglycerin can prevent PEP.
The development of a revised version of multi-center molecular Ornstein-Zernike equation
NASA Astrophysics Data System (ADS)
Kido, Kentaro; Yokogawa, Daisuke; Sato, Hirofumi
2012-04-01
Ornstein-Zernike (OZ)-type theory is a powerful tool to obtain 3-dimensional solvent distribution around solute molecule. Recently, we proposed multi-center molecular OZ method, which is suitable for parallel computing of 3D solvation structure. The distribution function in this method consists of two components, namely reference and residue parts. Several types of the function were examined as the reference part to investigate the numerical robustness of the method. As the benchmark, the method is applied to water, benzene in aqueous solution and single-walled carbon nanotube in chloroform solution. The results indicate that fully-parallelization is achieved by utilizing the newly proposed reference functions.
Integrated two-cylinder liquid piston Stirling engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Ning; Rickard, Robert; Pluckter, Kevin
2014-10-06
Heat engines utilizing the Stirling cycle may run on low temperature differentials with the capacity to function at high efficiency due to their near-reversible operation. However, current approaches to building Stirling engines are laborious and costly. Typically the components are assembled by hand and additional components require a corresponding increase in manufacturing complexity, akin to electronics before the integrated circuit. We present a simple and integrated approach to fabricating Stirling engines with precisely designed cylinders. We utilize computer aided design and one-step, planar machining to form all components of the engine. The engine utilizes liquid pistons and displacers to harnessmore » useful work from heat absorption and rejection. As a proof of principle of the integrated design, a two-cylinder engine is produced and characterized and liquid pumping is demonstrated.« less
Integrated two-cylinder liquid piston Stirling engine
NASA Astrophysics Data System (ADS)
Yang, Ning; Rickard, Robert; Pluckter, Kevin; Sulchek, Todd
2014-10-01
Heat engines utilizing the Stirling cycle may run on low temperature differentials with the capacity to function at high efficiency due to their near-reversible operation. However, current approaches to building Stirling engines are laborious and costly. Typically the components are assembled by hand and additional components require a corresponding increase in manufacturing complexity, akin to electronics before the integrated circuit. We present a simple and integrated approach to fabricating Stirling engines with precisely designed cylinders. We utilize computer aided design and one-step, planar machining to form all components of the engine. The engine utilizes liquid pistons and displacers to harness useful work from heat absorption and rejection. As a proof of principle of the integrated design, a two-cylinder engine is produced and characterized and liquid pumping is demonstrated.
An analytic approach to sunset diagrams in chiral perturbation theory: Theory and practice
NASA Astrophysics Data System (ADS)
Ananthanarayan, B.; Bijnens, Johan; Ghosh, Shayan; Hebbar, Aditya
2016-12-01
We demonstrate the use of several code implementations of the Mellin-Barnes method available in the public domain to derive analytic expressions for the sunset diagrams that arise in the two-loop contribution to the pion mass and decay constant in three-flavoured chiral perturbation theory. We also provide results for all possible two mass configurations of the sunset integral, and derive a new one-dimensional integral representation for the one mass sunset integral with arbitrary external momentum. Thoroughly annotated Mathematica notebooks are provided as ancillary files in the Electronic Supplementary Material to this paper, which may serve as pedagogical supplements to the methods described in this paper.
Silicon-nanomembrane-based photonic crystal nanostructures for chip-integrated open sensor systems
NASA Astrophysics Data System (ADS)
Chakravarty, Swapnajit; Lai, Wei-Cheng; Zou, Yi; Lin, Cheyun; Wang, Xiaolong; Chen, Ray T.
2011-11-01
We experimentally demonstrate two devices on the photonic crystal platform for chip-integrated optical absorption spectroscopy and chip-integrated biomolecular microarray assays. Infrared optical absorption spectroscopy and biomolecular assays based on conjugate-specific binding principles represent two dominant sensing mechanisms for a wide spectrum of applications in environmental pollution sensing in air and water, chem-bio agents and explosives detection for national security, microbial contamination sensing in food and beverages to name a few. The easy scalability of photonic crystal devices to any wavelength ensures that the sensing principles hold across a wide electromagnetic spectrum. Silicon, the workhorse of the electronics industry, is an ideal platform for the above optical sensing applications.
Joe, Yong S; Lee, Sun H; Hedin, Eric R; Kim, Young D
2013-06-01
We utilize a two-dimensional four-channel DNA model, with a tight-binding (TB) Hamiltonian, and investigate the temperature and the magnetic field dependence of the transport behavior of a short DNA molecule. Random variation of the hopping integrals due to the thermal structural disorder, which partially destroy phase coherence of electrons and reduce quantum interference, leads to a reduction of the localization length and causes suppressed overall transmission. We also incorporate a variation of magnetic field flux density into the hopping integrals as a phase factor and observe Aharonov-Bohm (AB) oscillations in the transmission. It is shown that for non-zero magnetic flux, the transmission zero leaves the real-energy axis and moves up into the complex-energy plane. We also point out that the hydrogen bonds between the base pair with flux variations play a role to determine the periodicity of AB oscillations in the transmission.
Zhong, Rong-Lin; Xu, Hong-Liang; Sun, Shi-Ling; Qiu, Yong-Qing; Zhao, Liang; Su, Zhong-Min
2013-09-28
An increasing number of chemists have focused on the investigations of two-electron/multicenter bond (2e/mc) that was first introduced to describe the structure of radical dimers. In this work, the dimerization of two isoelectronic radicals, triazaphenalenyl (TAP) and hexaazaphenalenyl (HAP) has been investigated in theory. Results show TAP2 is a stable dimer with stronger 2e/12c bond and larger interaction energy, while HAP2 is a less stable dimer with larger diradical character. Interestingly, the ultraviolet-visible absorption spectra suggest that the dimerization induces a longer wavelength absorption in visible area, which is dependent on the strength of dimerization. Significantly, the amplitude of second hyperpolarizability (γ(yyyy)) of HAP2 is 1.36 × 10(6) a.u. that is larger than 7.79 × 10(4) a.u. of TAP2 because of the larger diradical character of HAP2. Therefore, the results indicate that the strength of radical dimerization can be effectively detected by comparing the magnitude of third order non-linear optical response, which is beneficial for further theoretical and experimental studies on the properties of complexes formed by radical dimerization.
AIN-Based Packaging for SiC High-Temperature Electronics
NASA Technical Reports Server (NTRS)
Savrun, Ender
2004-01-01
Packaging made primarily of aluminum nitride has been developed to enclose silicon carbide-based integrated circuits (ICs), including circuits containing SiC-based power diodes, that are capable of operation under conditions more severe than can be withstood by silicon-based integrated circuits. A major objective of this development was to enable packaged SiC electronic circuits to operate continuously at temperatures up to 500 C. AlN-packaged SiC electronic circuits have commercial potential for incorporation into high-power electronic equipment and into sensors that must withstand high temperatures and/or high pressures in diverse applications that include exploration in outer space, well logging, and monitoring of nuclear power systems. This packaging embodies concepts drawn from flip-chip packaging of silicon-based integrated circuits. One or more SiC-based circuit chips are mounted on an aluminum nitride package substrate or sandwiched between two such substrates. Intimate electrical connections between metal conductors on the chip(s) and the metal conductors on external circuits are made by direct bonding to interconnections on the package substrate(s) and/or by use of holes through the package substrate(s). This approach eliminates the need for wire bonds, which have been the most vulnerable links in conventional electronic circuitry in hostile environments. Moreover, the elimination of wire bonds makes it possible to pack chips more densely than was previously possible.
NASA Astrophysics Data System (ADS)
Amouye Foumani, A.; Niknam, A. R.
2018-01-01
The response of copper films to irradiation with laser pulses of fluences in the range of 100-6000 J/m2 is simulated by using a modified combination of a two-temperature model (TTM) and molecular dynamics (MD). In this model, the dependency of the pulse penetration depth and the reflectivity of the target on electron temperature are taken into account. Also, the temperature-dependent electron-phonon coupling factor, electron thermal conductivity, and electron heat capacity are used in the simulations. Based on this model, the dependence of the integral reflectivity on pulse fluence, the changes in the film thickness, and the evolution of density and electron and lattice temperatures are obtained. Moreover, snapshots that show the melting and disintegration processes are presented. The disintegration starts at a fluence of 4200 J/m2, which corresponds with an absorbed fluence of 616 J/m2. The calculated values of integral reflectivity are in good agreement with the experimental data. The inclusion of such temperature-dependent absorption models in the TTM-MD method would facilitate the comparison of experimental data with simulation results.
Spatially controlled doping of two-dimensional SnS 2 through intercalation for electronics
Gong, Yongji; Yuan, Hongtao; Wu, Chun-Lan; ...
2018-02-26
Doped semiconductors are the most important building elements for modern electronic devices. In silicon-based integrated circuits, facile and controllable fabrication and integration of these materials can be realized without introducing a high-resistance interface. Besides, the emergence of two-dimensional (2D) materials enables the realization of atomically thin integrated circuits. However, the 2D nature of these materials precludes the use of traditional ion implantation techniques for carrier doping and further hinders device development10. Here, we demonstrate a solvent-based intercalation method to achieve p-type, n-type and degenerately doped semiconductors in the same parent material at the atomically thin limit. In contrast to naturallymore » grown n-type S-vacancy SnS 2, Cu intercalated bilayer SnS 2 obtained by this technique displays a hole field-effect mobility of ~40 cm 2 V -1 s -1, and the obtained Co-SnS 2 exhibits a metal-like behaviour with sheet resistance comparable to that of few-layer graphene. Combining this intercalation technique with lithography, an atomically seamless p–n–metal junction could be further realized with precise size and spatial control, which makes in-plane heterostructures practically applicable for integrated devices and other 2D materials. Therefore, the presented intercalation method can open a new avenue connecting the previously disparate worlds of integrated circuits and atomically thin materials.« less
Spatially controlled doping of two-dimensional SnS 2 through intercalation for electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gong, Yongji; Yuan, Hongtao; Wu, Chun-Lan
Doped semiconductors are the most important building elements for modern electronic devices. In silicon-based integrated circuits, facile and controllable fabrication and integration of these materials can be realized without introducing a high-resistance interface. Besides, the emergence of two-dimensional (2D) materials enables the realization of atomically thin integrated circuits. However, the 2D nature of these materials precludes the use of traditional ion implantation techniques for carrier doping and further hinders device development10. Here, we demonstrate a solvent-based intercalation method to achieve p-type, n-type and degenerately doped semiconductors in the same parent material at the atomically thin limit. In contrast to naturallymore » grown n-type S-vacancy SnS 2, Cu intercalated bilayer SnS 2 obtained by this technique displays a hole field-effect mobility of ~40 cm 2 V -1 s -1, and the obtained Co-SnS 2 exhibits a metal-like behaviour with sheet resistance comparable to that of few-layer graphene. Combining this intercalation technique with lithography, an atomically seamless p–n–metal junction could be further realized with precise size and spatial control, which makes in-plane heterostructures practically applicable for integrated devices and other 2D materials. Therefore, the presented intercalation method can open a new avenue connecting the previously disparate worlds of integrated circuits and atomically thin materials.« less
Spatially controlled doping of two-dimensional SnS2 through intercalation for electronics
NASA Astrophysics Data System (ADS)
Gong, Yongji; Yuan, Hongtao; Wu, Chun-Lan; Tang, Peizhe; Yang, Shi-Ze; Yang, Ankun; Li, Guodong; Liu, Bofei; van de Groep, Jorik; Brongersma, Mark L.; Chisholm, Matthew F.; Zhang, Shou-Cheng; Zhou, Wu; Cui, Yi
2018-04-01
Doped semiconductors are the most important building elements for modern electronic devices1. In silicon-based integrated circuits, facile and controllable fabrication and integration of these materials can be realized without introducing a high-resistance interface2,3. Besides, the emergence of two-dimensional (2D) materials enables the realization of atomically thin integrated circuits4-9. However, the 2D nature of these materials precludes the use of traditional ion implantation techniques for carrier doping and further hinders device development10. Here, we demonstrate a solvent-based intercalation method to achieve p-type, n-type and degenerately doped semiconductors in the same parent material at the atomically thin limit. In contrast to naturally grown n-type S-vacancy SnS2, Cu intercalated bilayer SnS2 obtained by this technique displays a hole field-effect mobility of 40 cm2 V-1 s-1, and the obtained Co-SnS2 exhibits a metal-like behaviour with sheet resistance comparable to that of few-layer graphene5. Combining this intercalation technique with lithography, an atomically seamless p-n-metal junction could be further realized with precise size and spatial control, which makes in-plane heterostructures practically applicable for integrated devices and other 2D materials. Therefore, the presented intercalation method can open a new avenue connecting the previously disparate worlds of integrated circuits and atomically thin materials.
Kor, Daryl J; Erlich, Jason; Gong, Michelle N; Malinchoc, Michael; Carter, Rickey E; Gajic, Ognjen; Talmor, Daniel S
2011-11-01
To evaluate the association between prehospitalization aspirin therapy and incident acute lung injury in a heterogeneous cohort of at-risk medical patients. This is a secondary analysis of a prospective multicenter international cohort investigation. Multicenter observational study including 20 US hospitals and two hospitals in Turkey. Consecutive, adult, nonsurgical patients admitted to the hospital with at least one major risk factor for acute lung injury. None. Baseline characteristics and acute lung injury risk factors/modifiers were identified. The presence of aspirin therapy and the propensity to receive this therapy were determined. The primary outcome was acute lung injury during hospitalization. Secondary outcomes included intensive care unit and hospital mortality and intensive care unit and hospital length of stay. Twenty-two hospitals enrolled 3855 at-risk patients over a 6-month period. Nine hundred seventy-six (25.3%) were receiving aspirin at the time of hospitalization. Two hundred forty (6.2%) patients developed acute lung injury. Univariate analysis noted a reduced incidence of acute lung injury in those receiving aspirin therapy (odds ratio [OR], 0.65; 95% confidence interval [CI], 0.46-0.90; p = .010). This association was attenuated in a stratified analysis based on deciles of aspirin propensity scores (Cochran-Mantel-Haenszel pooled OR, 0.70; 95% CI, 0.48-1.03; p = .072). After adjusting for the propensity to receive aspirin therapy, no statistically significant associations between prehospitalization aspirin therapy and acute lung injury were identified; however, a prospective clinical trial to further evaluate this association appears warranted.
Computational Nanotechnology of Materials, Electronics and Machines: Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Srivastava, Deepak
2001-01-01
This report presents the goals and research of the Integrated Product Team (IPT) on Devices and Nanotechnology. NASA's needs for this technology are discussed and then related to the research focus of the team. The two areas of focus for technique development are: 1) large scale classical molecular dynamics on a shared memory architecture machine; and 2) quantum molecular dynamics methodology. The areas of focus for research are: 1) nanomechanics/materials; 2) carbon based electronics; 3) BxCyNz composite nanotubes and junctions; 4) nano mechano-electronics; and 5) nano mechano-chemistry.
Alternative forms of the Spencer-Fano equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inokuti, M.; Kowari, K.
We point out a relation between the electron degradation spectra determined by two differing cross-section sets but subject to the same source. The relation takes a form of the Fredholm integral equation of the second kind and may be viewed as an alternative form of the Spencer-Fano equation. The relation leads to a precise definition of the partial degradation spectra of electrons of successive generations. It also provides a basis for the perturbation theory by which one calculates effects of small changes of cross-section data upon the electron degradation spectrum.
Beauty photoproduction using decays into electrons at HERA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chekanov, S.; Derrick, M.; Magill, S.
Photoproduction of beauty quarks in events with two jets and an electron associated with one of the jets has been studied with the ZEUS detector at HERA using an integrated luminosity of 120 pb{sup -1}. The fractions of events containing b quarks, and also of events containing c quarks, were extracted from a likelihood fit using variables sensitive to electron identification as well as to semileptonic decays. Total and differential cross sections for beauty and charm production were measured and compared with next-to-leading-order QCD calculations and Monte Carlo models.
Electron-pair-production cross section in the tip region of the positron spectrum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sud, K.K.; Sharma, D.K.
1984-11-01
The radial integrals for electron-pair production in a point Coulomb potential have been expressed by Sud, Sharma, and Sud in terms of the matrix generalization of the GAMMA function. Two new partial differential equations in photon energy satisfied by the matrix GAMMA function are obtained. We have obtained, on integrating the partial differential equations, accurate radial integrals as a function of photon energy for the pair production by intermediate-energy photons. The cross section in the tip region of the spectrum are calculated for photons of energy 5.0 to 10.0 MeV for /sup 92/U. The new technique results in extensive savingmore » in computer time as the basic radial integrals in terms of the hypergeometric function F/sub 2/ are computed at one photon energy for each pair of partial waves. The results of our calculations are compared with plane-wave Born-approximation results and with the calculations of Dugne and of Deck, Moroi, and Alling.« less
Taylor, J M; Law, N
1998-10-30
We investigate the importance of the assumed covariance structure for longitudinal modelling of CD4 counts. We examine how individual predictions of future CD4 counts are affected by the covariance structure. We consider four covariance structures: one based on an integrated Ornstein-Uhlenbeck stochastic process; one based on Brownian motion, and two derived from standard linear and quadratic random-effects models. Using data from the Multicenter AIDS Cohort Study and from a simulation study, we show that there is a noticeable deterioration in the coverage rate of confidence intervals if we assume the wrong covariance. There is also a loss in efficiency. The quadratic random-effects model is found to be the best in terms of correctly calibrated prediction intervals, but is substantially less efficient than the others. Incorrectly specifying the covariance structure as linear random effects gives too narrow prediction intervals with poor coverage rates. Fitting using the model based on the integrated Ornstein-Uhlenbeck stochastic process is the preferred one of the four considered because of its efficiency and robustness properties. We also use the difference between the future predicted and observed CD4 counts to assess an appropriate transformation of CD4 counts; a fourth root, cube root and square root all appear reasonable choices.
Three-dimensional integration of nanotechnologies for computing and data storage on a single chip
NASA Astrophysics Data System (ADS)
Shulaker, Max M.; Hills, Gage; Park, Rebecca S.; Howe, Roger T.; Saraswat, Krishna; Wong, H.-S. Philip; Mitra, Subhasish
2017-07-01
The computing demands of future data-intensive applications will greatly exceed the capabilities of current electronics, and are unlikely to be met by isolated improvements in transistors, data storage technologies or integrated circuit architectures alone. Instead, transformative nanosystems, which use new nanotechnologies to simultaneously realize improved devices and new integrated circuit architectures, are required. Here we present a prototype of such a transformative nanosystem. It consists of more than one million resistive random-access memory cells and more than two million carbon-nanotube field-effect transistors—promising new nanotechnologies for use in energy-efficient digital logic circuits and for dense data storage—fabricated on vertically stacked layers in a single chip. Unlike conventional integrated circuit architectures, the layered fabrication realizes a three-dimensional integrated circuit architecture with fine-grained and dense vertical connectivity between layers of computing, data storage, and input and output (in this instance, sensing). As a result, our nanosystem can capture massive amounts of data every second, store it directly on-chip, perform in situ processing of the captured data, and produce ‘highly processed’ information. As a working prototype, our nanosystem senses and classifies ambient gases. Furthermore, because the layers are fabricated on top of silicon logic circuitry, our nanosystem is compatible with existing infrastructure for silicon-based technologies. Such complex nano-electronic systems will be essential for future high-performance and highly energy-efficient electronic systems.
Three-dimensional integration of nanotechnologies for computing and data storage on a single chip.
Shulaker, Max M; Hills, Gage; Park, Rebecca S; Howe, Roger T; Saraswat, Krishna; Wong, H-S Philip; Mitra, Subhasish
2017-07-05
The computing demands of future data-intensive applications will greatly exceed the capabilities of current electronics, and are unlikely to be met by isolated improvements in transistors, data storage technologies or integrated circuit architectures alone. Instead, transformative nanosystems, which use new nanotechnologies to simultaneously realize improved devices and new integrated circuit architectures, are required. Here we present a prototype of such a transformative nanosystem. It consists of more than one million resistive random-access memory cells and more than two million carbon-nanotube field-effect transistors-promising new nanotechnologies for use in energy-efficient digital logic circuits and for dense data storage-fabricated on vertically stacked layers in a single chip. Unlike conventional integrated circuit architectures, the layered fabrication realizes a three-dimensional integrated circuit architecture with fine-grained and dense vertical connectivity between layers of computing, data storage, and input and output (in this instance, sensing). As a result, our nanosystem can capture massive amounts of data every second, store it directly on-chip, perform in situ processing of the captured data, and produce 'highly processed' information. As a working prototype, our nanosystem senses and classifies ambient gases. Furthermore, because the layers are fabricated on top of silicon logic circuitry, our nanosystem is compatible with existing infrastructure for silicon-based technologies. Such complex nano-electronic systems will be essential for future high-performance and highly energy-efficient electronic systems.
Wu, Albert W; Kharrazi, Hadi; Boulware, L Ebony; Snyder, Claire F
2013-08-01
This article presents the current state of patient-reported outcome measures and explains new opportunities for leveraging the recent adoption of electronic health records to expand the application of patient-reported outcomes in both clinical care and comparative effectiveness research. Historic developments of patient-reported outcome, electronic health record, and comparative effectiveness research are analyzed in two dimensions: patient centeredness and digitization. We pose the question, "What needs to be standardized around the collection of patient-reported outcomes in electronic health records for comparative effectiveness research?" We identified three converging trends: the progression of patient-reported outcomes toward greater patient centeredness and electronic adaptation; the evolution of electronic health records into personalized and fully digitized solutions; and the shift toward patient-oriented comparative effectiveness research. Related to this convergence, we propose an architecture for patient-reported outcome standardization that could serve as a first step toward a more comprehensive integration of patient-reported outcomes with electronic health record for both practice and research. The science of patient-reported outcome measurement has matured sufficiently to be integrated routinely into electronic health records and other electronic health solutions to collect data on an ongoing basis for clinical care and comparative effectiveness research. Further efforts and ideally coordinated efforts from various stakeholders are needed to refine the details of the proposed framework for standardization. Copyright © 2013 Elsevier Inc. All rights reserved.
Prospective research on infants with mild encephalopathy: the PRIME study.
Prempunpong, C; Chalak, L F; Garfinkle, J; Shah, B; Kalra, V; Rollins, N; Boyle, R; Nguyen, K-A; Mir, I; Pappas, A; Montaldo, P; Thayyil, S; Sánchez, P J; Shankaran, S; Laptook, A R; Sant'Anna, G
2018-01-01
To determine short-term outcomes of infants with evidence of hypoxia-ischemia at birth and classified as mild neonatal encephalopathy (NE) at <6 h of age. Prospective multicenter study. Mild NE was defined as ⩾1 abnormal category in modified Sarnat score. Primary outcome was any abnormality on early amplitude integrated electroencephalogram (aEEG) or seizures, abnormal brain magnetic resonance imaging (MRI) or neurological exam at discharge. A total of 54/63 (86%) of enrolled infants had data on components of the primary outcome, which was abnormal in 28/54 (52%): discontinuous aEEG (n=4), MRI (n=9) and discharge exam (n=22). Abnormal tone and/or incomplete Moro were the most common findings. MRI abnormalities were confined to cerebral cortex but two infants had basal ganglia and/or thalamus involvement. The 18 to 24 months follow-up is ongoing. A larger than expected proportion of mild NE infants with abnormal outcomes was observed. Future research should evaluate safety and efficacy of neuroprotection for mild NE.
Gao, Jian-Wei; Gao, Xue-Min; Zou, Ting; Zhao, Tian-Meng; Wang, Dong-Hua; Wu, Zong-Gui; Ren, Chang-Jie; Wang, Xing; Geng, Nai-Zhi; Zhao, Ming-Jun; Liang, Qiu-Ming; Feng, Xing; Yang, Bai-Song; Shi, Jun-Ling; Hua, Qi
2018-03-01
To evaluate the effectiveness and safety of Xinling Wan on patients with stable angina pectoris, a randomized, double-blinded, placebo parallel-controlled, multicenter clinical trial was conducted. A total of 232 subjects were enrolled and randomly divided into experiment group and placebo group. The experiment group was treated with Xinling Wan (two pills each time, three times daily) for 4 weeks, and the placebo group was treated with placebo. The effectiveness evaluation showed that Xinling Wan could significantly increase the total duration of treadmill exercise among patients with stable angina pectoris. FAS analysis showed that the difference value of the total exercise duration was between experiment group (72.11±139.32) s and placebo group (31.25±108.32) s. Xinling Wan could remarkably increase the total effective rate of angina pectoris symptom score, and the analysis showed that the total effective rate was 78.95% in experiment group and 42.61% in placebo group. The reduction of nitroglycerin dose was (2.45±2.41) tablets in experiment group and (0.50±2.24) tablets in placebo group on the basis of FAS analysis. The decrease of symptom integral was (4.68±3.49) in experiment group and (3.19±3.31) in placebo group based on FAS analysis. Besides, Xinling Wan could decrease the weekly attack time and the duration of angina pectoris. PPS analysis results were similar to those of FAS analysis. In conclusion, Xinling Wan has an obvious therapeutic effect in treating stable angina pectoris, with a good safety and a low incidence of adverse event and adverse reaction in experiment group. Copyright© by the Chinese Pharmaceutical Association.
Suzuki, Yasuo; Iida, Mitsuo; Ito, Hiroaki; Nishino, Haruo; Ohmori, Toshihide; Arai, Takehiro; Yokoyama, Tadashi; Okubo, Takanori; Hibi, Toshifumi
2017-05-01
The noninferiority of pH-dependent release mesalamine (Asacol) once daily (QD) to 3 times daily (TID) administration was investigated. This was a phase 3, multicenter, randomized, double-blind, parallel-group, active-control study, with dynamic and stochastic allocation using central registration. Patients with ulcerative colitis in remission (a bloody stool score of 0, and an ulcerative colitis disease activity index of ≤2), received the study drug (Asacol 2.4 g/d) for 48 weeks. The primary efficacy endpoint of the nonrecurrence rate was assessed on the full analysis set. The noninferiority margin was 10%. Six hundred and four subjects were eligible and were allocated; 603 subjects received the study drug. The full analysis set comprised 602 subjects (QD: 301, TID: 301). Nonrecurrence rates were 88.4% in the QD and 89.6% in the TID. The difference between nonrecurrence rates was -1.3% (95% confidence interval: -6.2, 3.7), confirming noninferiority. No differences in the safety profile were observed between the two treatment groups. On post hoc analysis by integrating the QD and the TID, nonrecurrence rate with a mucosal appearance score of 0 at determination of eligibility was significantly higher than the score of 1. The mean compliance rates were 97.7% in the QD and 98.1% in the TID. QD dosing with Asacol is as effective and safe as TID for maintenance of remission in patients with ulcerative colitis. Additionally, this study indicated that maintaining a good mucosal state is the key for longer maintenance of remission.
Suzuki, Yasuo; Iida, Mitsuo; Ito, Hiroaki; Nishino, Haruo; Ohmori, Toshihide; Arai, Takehiro; Yokoyama, Tadashi; Okubo, Takanori
2017-01-01
Background: The noninferiority of pH-dependent release mesalamine (Asacol) once daily (QD) to 3 times daily (TID) administration was investigated. Methods: This was a phase 3, multicenter, randomized, double-blind, parallel-group, active-control study, with dynamic and stochastic allocation using central registration. Patients with ulcerative colitis in remission (a bloody stool score of 0, and an ulcerative colitis disease activity index of ≤2), received the study drug (Asacol 2.4 g/d) for 48 weeks. The primary efficacy endpoint of the nonrecurrence rate was assessed on the full analysis set. The noninferiority margin was 10%. Results: Six hundred and four subjects were eligible and were allocated; 603 subjects received the study drug. The full analysis set comprised 602 subjects (QD: 301, TID: 301). Nonrecurrence rates were 88.4% in the QD and 89.6% in the TID. The difference between nonrecurrence rates was −1.3% (95% confidence interval: −6.2, 3.7), confirming noninferiority. No differences in the safety profile were observed between the two treatment groups. On post hoc analysis by integrating the QD and the TID, nonrecurrence rate with a mucosal appearance score of 0 at determination of eligibility was significantly higher than the score of 1. The mean compliance rates were 97.7% in the QD and 98.1% in the TID. Conclusions: QD dosing with Asacol is as effective and safe as TID for maintenance of remission in patients with ulcerative colitis. Additionally, this study indicated that maintaining a good mucosal state is the key for longer maintenance of remission. PMID:28368909
Synchronized voltage contrast display analysis system
NASA Technical Reports Server (NTRS)
Johnston, M. F.; Shumka, A.; Miller, E.; Evans, K. C. (Inventor)
1982-01-01
An apparatus and method for comparing internal voltage potentials of first and second operating electronic components such as large scale integrated circuits (LSI's) in which voltage differentials are visually identified via an appropriate display means are described. More particularly, in a first embodiment of the invention a first and second scanning electron microscope (SEM) are configured to scan a first and second operating electronic component respectively. The scan pattern of the second SEM is synchronized to that of the first SEM so that both simultaneously scan corresponding portions of the two operating electronic components. Video signals from each SEM corresponding to secondary electron signals generated as a result of a primary electron beam intersecting each operating electronic component in accordance with a predetermined scan pattern are provided to a video mixer and color encoder.
Symbolic programming language in molecular multicenter integral problem
NASA Astrophysics Data System (ADS)
Safouhi, Hassan; Bouferguene, Ahmed
It is well known that in any ab initio molecular orbital (MO) calculation, the major task involves the computation of molecular integrals, among which the computation of three-center nuclear attraction and Coulomb integrals is the most frequently encountered. As the molecular system becomes larger, computation of these integrals becomes one of the most laborious and time-consuming steps in molecular systems calculation. Improvement of the computational methods of molecular integrals would be indispensable to further development in computational studies of large molecular systems. To develop fast and accurate algorithms for the numerical evaluation of these integrals over B functions, we used nonlinear transformations for improving convergence of highly oscillatory integrals. These methods form the basis of new methods for solving various problems that were unsolvable otherwise and have many applications as well. To apply these nonlinear transformations, the integrands should satisfy linear differential equations with coefficients having asymptotic power series in the sense of Poincaré, which in their turn should satisfy some limit conditions. These differential equations are very difficult to obtain explicitly. In the case of molecular integrals, we used a symbolic programming language (MAPLE) to demonstrate that all the conditions required to apply these nonlinear transformation methods are satisfied. Differential equations are obtained explicitly, allowing us to demonstrate that the limit conditions are also satisfied.
Jung, Sook-In; Shin, Jong Hee; Song, Jae-Hoon; Peck, Kyong Ran; Lee, Kyungwon; Kim, Mi-Na; Chang, Hyun Ha; Moon, Chi Sook
2010-06-01
Multicenter data on in vitro susceptibility of Candida bloodstream isolates to echinocandin antifungal agents is still lacking in South Korea. We performed a prospective multicenter study to determine the species distribution of Candida bloodstream isolates and their susceptibility to five antifungal agents, including caspofungin and micafungin. A total of 639 isolates were collected from 20 tertiary hospitals between September 2006 and August 2007. Antifungal susceptibilities were determined through the use of the CLSI broth microdilution method M27-A3. The overall species distribution was as follows; Candida albicans (38%), Candida parapsilosis (26%), Candia tropicalis (20%), Candida glabrata (11%), and miscellaneous Candida species (5%). Although C. parapsilosis and miscellaneous Candida species were less susceptible to both echinocandins, all 639 isolates were susceptible to both caspofungin and micafungin (MIC,
Borlawsky, Tara; Hota, Bala; Lin, Michael Y.; Khan, Yosef; Young, Jeremy; Santangelo, Jennifer; Stevenson, Kurt B.
2008-01-01
The most prevalent hospital-acquired infections in the United States are bloodstream infections (BSIs) associated with the presence of a central venous catheter. There is currently a movement, including national organizations such as the Centers for Medicare and Medicaid Services as well as consumer, quality improvement and patient safety groups, encouraging the standardization of reporting and aggregation of such nosocomial infection data to increase and improve reporting, and enable rate comparisons among healthcare institutions. Domain modeling is a well-known method for designing interoperable processes that take advantage of existing data and legacy systems. We have combined such a model-driven design approach with the use of partitioned clinical and business logic knowledgebases in order to employ a previously validated electronic BSI surveillance algorithm in the context of a multi-center study. PMID:18999213
NASA Astrophysics Data System (ADS)
Lei, Jie
2011-03-01
In order to understand the electronic and transport properties of organic field-effect transistor (FET) materials, we theoretically studied the polarons in two-dimensional systems using a tight-binding model with the Holstein type and Su--Schrieffer--Heeger type electron--lattice couplings. By numerical calculations, it was found that a carrier accepts four kinds of localization, which are named the point polaron, two-dimensional polaron, one-dimensional polaron, and the extended state. The degree of localization is sensitive to the following parameters in the model: the strength and type of electron--lattice couplings, and the signs and relative magnitudes of transfer integrals. When a parameter set for a single-crystal phase of pentacene is applied within the Holstein model, a considerably delocalized hole polaron is found, consistent with the bandlike transport mechanism.
Structural insights into electron transfer in caa3-type cytochrome oxidase
Lyons, Joseph A.; Aragão, David; Slattery, Orla; Pisliakov, Andrei V.; Soulimane, Tewfik; Caffrey, Martin
2012-01-01
Summary Paragraph Cytochrome c oxidase is a member of the heme copper oxidase superfamily (HCO)1. HCOs function as the terminal enzymes in the respiratory chain of mitochondria and aerobic prokaryotes, coupling molecular oxygen reduction to transmembrane proton pumping. Integral to the enzyme’s function is the transfer of electrons from cytochrome c to the oxidase via a transient association of the two proteins. Electron entry and exit are proposed to occur from the same site on cytochrome c2–4. Here we report the crystal structure of the caa3-type cytochrome oxidase from Thermus thermophilus, which has a covalently tethered cytochrome c domain. Crystals were grown in a bicontinuous mesophase using a synthetic short-chain monoacylglycerol as the hosting lipid. From the electron density map, at 2.36 Å resolution, a novel integral membrane subunit and a native glycoglycerophospholipid embedded in the complex were identified. Contrary to previous electron transfer mechanisms observed for soluble cytochrome c, the structure reveals the architecture of the electron transfer complex for the fused cupredoxin/cytochrome c domain which implicates different sites on cytochrome c for electron entry and exit. Support for an alternative to the classical proton gate characteristic of this HCO class is presented. PMID:22763450
Privacy protection for patients with substance use problems.
Hu, Lianne Lian; Sparenborg, Steven; Tai, Betty
2011-01-01
Many Americans with substance use problems will have opportunities to receive coordinated health care through the integration of primary care and specialty care for substance use disorders under the Patient Protection and Affordable Care Act of 2010. Sharing of patient health records among care providers is essential to realize the benefits of electronic health records. Health information exchange through meaningful use of electronic health records can improve health care safety, quality, and efficiency. Implementation of electronic health records and health information exchange presents great opportunities for health care integration, but also makes patient privacy potentially vulnerable. Privacy issues are paramount for patients with substance use problems. This paper discusses major differences between two federal privacy laws associated with health care for substance use disorders, identifies health care problems created by privacy policies, and describes potential solutions to these problems through technology innovation and policy improvement.
Privacy protection for patients with substance use problems
Hu, Lianne Lian; Sparenborg, Steven; Tai, Betty
2011-01-01
Many Americans with substance use problems will have opportunities to receive coordinated health care through the integration of primary care and specialty care for substance use disorders under the Patient Protection and Affordable Care Act of 2010. Sharing of patient health records among care providers is essential to realize the benefits of electronic health records. Health information exchange through meaningful use of electronic health records can improve health care safety, quality, and efficiency. Implementation of electronic health records and health information exchange presents great opportunities for health care integration, but also makes patient privacy potentially vulnerable. Privacy issues are paramount for patients with substance use problems. This paper discusses major differences between two federal privacy laws associated with health care for substance use disorders, identifies health care problems created by privacy policies, and describes potential solutions to these problems through technology innovation and policy improvement. PMID:24474860
Smart electronics and microengineering: the Australian focus
NASA Astrophysics Data System (ADS)
Hariz, Alex
1998-04-01
Integrated MEMS together with signal-conditioning electronics on the same chip appears to be the ultimate solution to realizing smart computer devices integratable into larger systems. This in principle will lead to systems with decentralized intelligence leading to applications in numerous fields. It is conceived that such devices would be the product of merging two mature technologies, that of microsensors and that of IC manufacture which is enjoying a well established success. Using common and suitable materials it is reasonable to expect a high degree of compatibility with little modification to standard processes. The various aspects of this co-integration will be analyzed and factors critical to the viability of the process, that go beyond mere technical feasibility will be highlighted. Australian research in this area is strong and continues to grow. We will pinpoint opportunities and constraints to the promising prospect of smart electronics and MEMS.
Gate-controlled electromechanical backaction induced by a quantum dot
NASA Astrophysics Data System (ADS)
Okazaki, Yuma; Mahboob, Imran; Onomitsu, Koji; Sasaki, Satoshi; Yamaguchi, Hiroshi
2016-04-01
Semiconductor-based quantum structures integrated into mechanical resonators have emerged as a unique platform for generating entanglement between macroscopic phononic and mesocopic electronic degrees of freedom. A key challenge to realizing this is the ability to create and control the coupling between two vastly dissimilar systems. Here, such coupling is demonstrated in a hybrid device composed of a gate-defined quantum dot integrated into a piezoelectricity-based mechanical resonator enabling milli-Kelvin phonon states to be detected via charge fluctuations in the quantum dot. Conversely, the single electron transport in the quantum dot can induce a backaction onto the mechanics where appropriate bias of the quantum dot can enable damping and even current-driven amplification of the mechanical motion. Such electron transport induced control of the mechanical resonator dynamics paves the way towards a new class of hybrid semiconductor devices including a current injected phonon laser and an on-demand single phonon emitter.
NASA Astrophysics Data System (ADS)
Henstra, A.; Wenckebach, W. Th.
1991-02-01
A review is given of newly developed pulsed Electron Spin Resonance (ESR) methods for dynamic polarization of nuclear spins. The application of two of these methods, Nuclear Orientation Via Electron spin Locking (NOVEL) and the Integrated Solid Effect (ISE), for the polarization of nuclear spins in semiconductors is discussed in more detail. It is proposed to use these methods to study the ESR spectrum of unpaired electrons in the vicinity of muons that are bound in a solid. Thus, ESR would be observed with a sensitivity which is enhanced by about ten orders of magnitude compared to conventional ESR.
Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S.; Thwaites, David I.; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar
2016-01-01
Abstract The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP ‘Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques’ was conducted in 2009–2012 as an extension of previously developed audit programs. Material and methods. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. Results. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Discussion. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing procedures in their national programs. PMID:26934916
Izewska, Joanna; Wesolowska, Paulina; Azangwe, Godfrey; Followill, David S; Thwaites, David I; Arib, Mehenna; Stefanic, Amalia; Viegas, Claudio; Suming, Luo; Ekendahl, Daniela; Bulski, Wojciech; Georg, Dietmar
2016-07-01
The International Atomic Energy Agency (IAEA) has a long tradition of supporting development of methodologies for national networks providing quality audits in radiotherapy. A series of co-ordinated research projects (CRPs) has been conducted by the IAEA since 1995 assisting national external audit groups developing national audit programs. The CRP 'Development of Quality Audits for Radiotherapy Dosimetry for Complex Treatment Techniques' was conducted in 2009-2012 as an extension of previously developed audit programs. The CRP work described in this paper focused on developing and testing two steps of dosimetry audit: verification of heterogeneity corrections, and treatment planning system (TPS) modeling of small MLC fields, which are important for the initial stages of complex radiation treatments, such as IMRT. The project involved development of a new solid slab phantom with heterogeneities containing special measurement inserts for thermoluminescent dosimeters (TLD) and radiochromic films. The phantom and the audit methodology has been developed at the IAEA and tested in multi-center studies involving the CRP participants. The results of multi-center testing of methodology for two steps of dosimetry audit show that the design of audit procedures is adequate and the methodology is feasible for meeting the audit objectives. A total of 97% TLD results in heterogeneity situations obtained in the study were within 3% and all results within 5% agreement with the TPS predicted doses. In contrast, only 64% small beam profiles were within 3 mm agreement between the TPS calculated and film measured doses. Film dosimetry results have highlighted some limitations in TPS modeling of small beam profiles in the direction of MLC leave movements. Through multi-center testing, any challenges or difficulties in the proposed audit methodology were identified, and the methodology improved. Using the experience of these studies, the participants could incorporate the auditing procedures in their national programs.
Coulomb engineering of the bandgap and excitons in two-dimensional materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raja, Archana; Chaves, Andrey; Yu, Jaeeun
Here, the ability to control the size of the electronic bandgap is an integral part of solid-state technology. Atomically thin two-dimensional crystals offer a new approach for tuning the energies of the electronic states based on the unusual strength of the Coulomb interaction in these materials and its environmental sensitivity. Here, we show that by engineering the surrounding dielectric environment, one can tune the electronic bandgap and the exciton binding energy in monolayers of WS 2 and WSe 2 by hundreds of meV. We exploit this behaviour to present an in-plane dielectric heterostructure with a spatially dependent bandgap, as anmore » initial step towards the creation of diverse lateral junctions with nanoscale resolution.« less
Coulomb engineering of the bandgap and excitons in two-dimensional materials
Raja, Archana; Chaves, Andrey; Yu, Jaeeun; ...
2017-05-04
Here, the ability to control the size of the electronic bandgap is an integral part of solid-state technology. Atomically thin two-dimensional crystals offer a new approach for tuning the energies of the electronic states based on the unusual strength of the Coulomb interaction in these materials and its environmental sensitivity. Here, we show that by engineering the surrounding dielectric environment, one can tune the electronic bandgap and the exciton binding energy in monolayers of WS 2 and WSe 2 by hundreds of meV. We exploit this behaviour to present an in-plane dielectric heterostructure with a spatially dependent bandgap, as anmore » initial step towards the creation of diverse lateral junctions with nanoscale resolution.« less
Coulomb engineering of the bandgap and excitons in two-dimensional materials
Raja, Archana; Chaves, Andrey; Yu, Jaeeun; Arefe, Ghidewon; Hill, Heather M.; Rigosi, Albert F.; Berkelbach, Timothy C.; Nagler, Philipp; Schüller, Christian; Korn, Tobias; Nuckolls, Colin; Hone, James; Brus, Louis E.; Heinz, Tony F.; Reichman, David R.; Chernikov, Alexey
2017-01-01
The ability to control the size of the electronic bandgap is an integral part of solid-state technology. Atomically thin two-dimensional crystals offer a new approach for tuning the energies of the electronic states based on the unusual strength of the Coulomb interaction in these materials and its environmental sensitivity. Here, we show that by engineering the surrounding dielectric environment, one can tune the electronic bandgap and the exciton binding energy in monolayers of WS2 and WSe2 by hundreds of meV. We exploit this behaviour to present an in-plane dielectric heterostructure with a spatially dependent bandgap, as an initial step towards the creation of diverse lateral junctions with nanoscale resolution. PMID:28469178
Khuri-Yakub, B T; Oralkan, Omer; Nikoozadeh, Amin; Wygant, Ira O; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O'Donnell, Matthew; Truong, Uyen; Sahn, David J
2010-01-01
Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics.
ERIC Educational Resources Information Center
Emslie, Graham J.; Findling, Robert L.; Yeung, Paul P.; Kunz, Nadia R.; Li, Yunfeng
2007-01-01
Objective: The safety, efficacy, and tolerability of venlafaxine extended release (ER) in subjects ages 7 to 17 years with major depressive disorder were evaluated in two multicenter, randomized, double-blind, placebo-controlled trials conducted between October 1997 and August 2001. Method: Participants received venlafaxine ER (flexible dose,…
NASA Astrophysics Data System (ADS)
Alfaraj, Nasir; Hussain, Aftab M.; Torres Sevilla, Galo A.; Ghoneim, Mohamed T.; Rojas, Jhonathan P.; Aljedaani, Abdulrahman B.; Hussain, Muhammad M.
2015-10-01
Flexibility can bring a new dimension to state-of-the-art electronics, such as rollable displays and integrated circuit systems being transformed into more powerful resources. Flexible electronics are typically hosted on polymeric substrates. Such substrates can be bent and rolled up, but cannot be independently fixed at the rigid perpendicular position necessary to realize rollable display-integrated gadgets and electronics. A reversibly bistable material can assume two stable states in a reversible way: flexibly rolled state and independently unbent state. Such materials are used in cycling and biking safety wristbands and a variety of ankle bracelets for orthopedic healthcare. They are often wrapped around an object with high impulsive force loading. Here, we study the effects of cumulative impulsive force loading on thinned (25 μm) flexible silicon-based n-channel metal-oxide-semiconductor field-effect transistor devices housed on a reversibly bistable flexible platform. We found that the transistors have maintained their high performance level up to an accumulated 180 kN of impact force loading. The gate dielectric layers have maintained their reliability, which is evidenced by the low leakage current densities. Also, we observed low variation in the effective electron mobility values, which manifests that the device channels have maintained their carrier transport properties.
NASA Astrophysics Data System (ADS)
Győrffy, Werner; Knizia, Gerald; Werner, Hans-Joachim
2017-12-01
We present the theory and algorithms for computing analytical energy gradients for explicitly correlated second-order Møller-Plesset perturbation theory (MP2-F12). The main difficulty in F12 gradient theory arises from the large number of two-electron integrals for which effective two-body density matrices and integral derivatives need to be calculated. For efficiency, the density fitting approximation is used for evaluating all two-electron integrals and their derivatives. The accuracies of various previously proposed MP2-F12 approximations [3C, 3C(HY1), 3*C(HY1), and 3*A] are demonstrated by computing equilibrium geometries for a set of molecules containing first- and second-row elements, using double-ζ to quintuple-ζ basis sets. Generally, the convergence of the bond lengths and angles with respect to the basis set size is strongly improved by the F12 treatment, and augmented triple-ζ basis sets are sufficient to closely approach the basis set limit. The results obtained with the different approximations differ only very slightly. This paper is the first step towards analytical gradients for coupled-cluster singles and doubles with perturbative treatment of triple excitations, which will be presented in the second part of this series.
Labeling for Big Data in radiation oncology: The Radiation Oncology Structures ontology.
Bibault, Jean-Emmanuel; Zapletal, Eric; Rance, Bastien; Giraud, Philippe; Burgun, Anita
2018-01-01
Leveraging Electronic Health Records (EHR) and Oncology Information Systems (OIS) has great potential to generate hypotheses for cancer treatment, since they directly provide medical data on a large scale. In order to gather a significant amount of patients with a high level of clinical details, multicenter studies are necessary. A challenge in creating high quality Big Data studies involving several treatment centers is the lack of semantic interoperability between data sources. We present the ontology we developed to address this issue. Radiation Oncology anatomical and target volumes were categorized in anatomical and treatment planning classes. International delineation guidelines specific to radiation oncology were used for lymph nodes areas and target volumes. Hierarchical classes were created to generate The Radiation Oncology Structures (ROS) Ontology. The ROS was then applied to the data from our institution. Four hundred and seventeen classes were created with a maximum of 14 children classes (average = 5). The ontology was then converted into a Web Ontology Language (.owl) format and made available online on Bioportal and GitHub under an Apache 2.0 License. We extracted all structures delineated in our department since the opening in 2001. 20,758 structures were exported from our "record-and-verify" system, demonstrating a significant heterogeneity within a single center. All structures were matched to the ROS ontology before integration into our clinical data warehouse (CDW). In this study we describe a new ontology, specific to radiation oncology, that reports all anatomical and treatment planning structures that can be delineated. This ontology will be used to integrate dosimetric data in the Assistance Publique-Hôpitaux de Paris CDW that stores data from 6.5 million patients (as of February 2017).
Labeling for Big Data in radiation oncology: The Radiation Oncology Structures ontology
Zapletal, Eric; Rance, Bastien; Giraud, Philippe; Burgun, Anita
2018-01-01
Purpose Leveraging Electronic Health Records (EHR) and Oncology Information Systems (OIS) has great potential to generate hypotheses for cancer treatment, since they directly provide medical data on a large scale. In order to gather a significant amount of patients with a high level of clinical details, multicenter studies are necessary. A challenge in creating high quality Big Data studies involving several treatment centers is the lack of semantic interoperability between data sources. We present the ontology we developed to address this issue. Methods Radiation Oncology anatomical and target volumes were categorized in anatomical and treatment planning classes. International delineation guidelines specific to radiation oncology were used for lymph nodes areas and target volumes. Hierarchical classes were created to generate The Radiation Oncology Structures (ROS) Ontology. The ROS was then applied to the data from our institution. Results Four hundred and seventeen classes were created with a maximum of 14 children classes (average = 5). The ontology was then converted into a Web Ontology Language (.owl) format and made available online on Bioportal and GitHub under an Apache 2.0 License. We extracted all structures delineated in our department since the opening in 2001. 20,758 structures were exported from our “record-and-verify” system, demonstrating a significant heterogeneity within a single center. All structures were matched to the ROS ontology before integration into our clinical data warehouse (CDW). Conclusion In this study we describe a new ontology, specific to radiation oncology, that reports all anatomical and treatment planning structures that can be delineated. This ontology will be used to integrate dosimetric data in the Assistance Publique—Hôpitaux de Paris CDW that stores data from 6.5 million patients (as of February 2017). PMID:29351341
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Jingsong; Meunier, Vincent; Tian, Yong-Hui
2010-01-01
Phenalenyl and its derivatives have recently attracted a great deal of interest as a result of a two-electron multicenter (2e/mc) - bonding between two -stacked phenalenyl units. The 2e/mc bonded -dimers are close in energy to the -dimers of phenalenyl and therefore fickle properties may emerge from bond fluctuation, yielding smart -functional materials. Here, we examine the valence tautomerization of two cyclo-biphenalenyl biradicaloid molecular materials with chair and boat conformations by spin-restricted (R) and unrestricted (U) DFT using the M06 and B3LYP functionals. We found that the chair conformation involves a 2e/4c - bonded structure, whereas the boat conformation involvesmore » a 2e/12c - bonded structure on their potential energy surfaces. The global minimum for the chair conformation is the -bonded structure, whereas it is the - bonded structure for the boat conformation. The chair conformation exhibits a stepwise [3,3]-sigmatropic rearrangement, and calculations predict a negligible paramagnetic susceptibility near room temperature. In comparison, the paramagnetism of the boat conformation should be observable by SQUID and ESR. According to the energy differences of the respective - and -dimers of the two conformations and the UV-vis calculations, the color of the chair conformation is expected to become darker, whereas that of the boat conformation should become lighter with increasing temperature.« less
Choi, Chang Won; Park, Moon Sung
2015-10-01
The Korean Neonatal Network (KNN), a nationwide prospective registry of very-low-birth-weight (VLBW, < 1,500 g at birth) infants, was launched in April 2013. Data management (DM) and site-visit monitoring (SVM) were crucial in ensuring the quality of the data collected from 55 participating hospitals across the country on 116 clinical variables. We describe the processes and results of DM and SVM performed during the establishment stage of the registry. The DM procedure included automated proof checks, electronic data validation, query creation, query resolution, and revalidation of the corrected data. SVM included SVM team organization, identification of unregistered cases, source document verification, and post-visit report production. By March 31, 2015, 4,063 VLBW infants were registered and 1,693 queries were produced. Of these, 1,629 queries were resolved and 64 queries remain unresolved. By November 28, 2014, 52 participating hospitals were visited, with 136 site-visits completed since April 2013. Each participating hospital was visited biannually. DM and SVM were performed to ensure the quality of the data collected for the KNN registry. Our experience with DM and SVM can be applied for similar multi-center registries with large numbers of participating centers.
III-nitride integration on ferroelectric materials of lithium niobate by molecular beam epitaxy
NASA Astrophysics Data System (ADS)
Namkoong, Gon; Lee, Kyoung-Keun; Madison, Shannon M.; Henderson, Walter; Ralph, Stephen E.; Doolittle, W. Alan
2005-10-01
Integration of III-nitride electrical devices on the ferroelectric material lithium niobate (LiNbO3) has been demonstrated. As a ferroelectric material, lithium niobate has a polarization which may provide excellent control of the polarity of III-nitrides. However, while high temperature, 1000°C, thermal treatments produce atomically smooth surfaces, improving adhesion of GaN epitaxial layers on lithium niobate, repolarization of the substrate in local domains occurs. These effects result in multi domains of mixed polarization in LiNbO3, producing inversion domains in subsequent GaN epilayers. However, it is found that AlN buffer layers suppress inversion domains of III-nitrides. Therefore, two-dimensional electron gases in AlGaN /GaN heterojunction structures are obtained. Herein, the demonstration of the monolithic integration of high power devices with ferroelectric materials presents possibilities to control LiNbO3 modulators on compact optoelectronic/electronic chips.
Mehmood, Amber; Chan, Edward; Allen, Katharine; Al-Kashmiri, Ammar; Al-Busaidi, Ali; Al-Abri, Jehan; Al-Yazidi, Mohamed; Al-Maniri, Abdullah; Hyder, Adnan A.
2017-01-01
ABSTRACT Background: Trauma registries (TRs) play a vital role in the assessment of trauma care, but are often underutilized in countries with a high burden of injuries. Objectives: We investigated whether information and communications technology (ICT) such as mobile health (mHealth) could enable the design of a tablet-based application for healthcare professionals. This would be used to inform trauma care and acquire surveillance data for injury control and prevention in Oman. This paper focuses on documenting the implementation process in a healthcare setting. Methods: The study was conducted using an ICT implementation framework consisting of multistep assessment, development and pilot testing of an electronic tablet-based TR. The pilot study was conducted at two large hospitals in Oman, followed by detailed evaluation of the process, system and impact of implementation. Results: The registry was designed to provide comprehensive information on each trauma case from the location of injury until hospital discharge, with variables organized to cover 11 domains of demographic and clinical information. The pilot study demonstrated that the registry was user friendly and reliable, and the implementation framework was useful in planning for the Omani hospital setting. Data collection by trained and dedicated nurses proved to be more feasible, efficient and reliable than real-time data entry by care providers. Conclusions: The initial results show the promising potential of a user-friendly, comprehensive electronic TR through the use of mHealth tools. The pilot test in two hospitals indicates that the registry can be used to create a multicenter trauma database. PMID:29027507
Rare Copy Number Variation in Treatment-Resistant Major Depressive Disorder
O’Dushlaine, Colm; Ripke, Stephan; Ruderfer, Douglas M.; Hamilton, Steven P.; Fava, Maurizio; Iosifescu, Dan V.; Kohane, Isaac S.; Churchill, Susanne E.; Castro, Victor M.; Clements, Caitlin C.; Blumenthal, Sarah R.; Murphy, Shawn N.; Smoller, Jordan W.; Perlis, Roy H.
2014-01-01
Background While antidepressant treatment response appears to be partially heritable, no consistent genetic associations have been identified. Large, rare copy number variants (CNVs) play a role in other neuropsychiatric diseases, so we assessed their association with treatment-resistant depression (TRD). Methods We analyzed data from two genome-wide association studies comprising 1263 Caucasian patients with major depressive disorder. One was drawn from a large health system by applying natural language processing to electronic health records (i2b2 cohort). The second consisted of a multicenter study of sequential antidepressant treatments, Sequenced Treatment Alternatives to Relieve Depression. The Birdsuite package was used to identify rare deletions and duplications. Individuals without symptomatic remission, despite two antidepressant treatment trials, were contrasted with those who remitted with a first treatment trial. Results CNV data were derived for 778 subjects in the i2b2 cohort, including 300 subjects (37%) with TRD, and 485 subjects in Sequenced Treatment Alternatives to Relieve Depression cohort, including 152 (31%) with TRD. CNV burden analyses identified modest enrichment of duplications in cases (empirical p = .04 for duplications of 100–200 kilobase) and a particular deletion region spanning gene PABPC4L (empirical p = .02, 6 cases: 0 controls). Pathway analysis suggested enrichment of CNVs intersecting genes regulating actin cytoskeleton. However, none of these associations survived genome-wide correction. Conclusions Contribution of rare CNVs to TRD appears to be modest, individually or in aggregate. The electronic health record-based methodology demonstrated here should facilitate collection of larger TRD cohorts necessary to further characterize these effects. PMID:24529801
Höfener, Sebastian; Bischoff, Florian A; Glöss, Andreas; Klopper, Wim
2008-06-21
In the recent years, Slater-type geminals (STGs) have been used with great success to expand the first-order wave function in an explicitly-correlated perturbation theory. The present work reports on this theory's implementation in the framework of the Turbomole suite of programs. A formalism is presented for evaluating all of the necessary molecular two-electron integrals by means of the Obara-Saika recurrence relations, which can be applied when the STG is expressed as a linear combination of a small number (n) of Gaussians (STG-nG geminal basis). In the Turbomole implementation of the theory, density fitting is employed and a complementary auxiliary basis set (CABS) is used for the resolution-of-the-identity (RI) approximation of explicitly-correlated theory. By virtue of this RI approximation, the calculation of molecular three- and four-electron integrals is avoided. An approximation is invoked to avoid the two-electron integrals over the commutator between the operators of kinetic energy and the STG. This approximation consists of computing commutators between matrices in place of operators. Integrals over commutators between operators would have occurred if the theory had been formulated and implemented as proposed originally. The new implementation in Turbomole was tested by performing a series of calculations on rotational conformers of the alkanols n-propanol through n-pentanol. Basis-set requirements concerning the orbital basis, the auxiliary basis set for density fitting and the CABS were investigated. Furthermore, various (constrained) optimizations of the amplitudes of the explicitly-correlated double excitations were studied. These amplitudes can be optimized in orbital-variant and orbital-invariant manners, or they can be kept fixed at the values governed by the rational generator approach, that is, by the electron cusp conditions. Electron-correlation effects beyond the level of second-order perturbation theory were accounted for by conventional coupled-cluster calculations with single, double and perturbative triple excitations [CCSD(T)]. The explicitly-correlated perturbation theory results were combined with CCSD(T) results and compared with literature data obtained by basis-set extrapolation.
Design and performance of a beetle-type double-tip scanning tunneling microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaschinsky, Philipp; Coenen, Peter; Pirug, Gerhard
2006-09-15
A combination of a double-tip scanning tunneling microscope with a scanning electron microscope in ultrahigh vacuum environment is presented. The compact beetle-type design made it possible to integrate two independently driven scanning tunneling microscopes in a small space. Moreover, an additional level for coarse movement allows the decoupling of the translation and approach of the tunneling tip. The position of the two tips can be controlled from the millimeter scale down to 50 nm with the help of an add-on electron microscope. The instrument is capable of atomic resolution imaging with each tip.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tandy, P.; Yu, Ming; Leahy, C.
2015-03-28
An upgrade of the previous self-consistent and environment-dependent linear combination of atomic orbitals Hamiltonian (referred as SCED-LCAO) has been developed. This improved version of the semi-empirical SCED-LCAO Hamiltonian, in addition to the inclusion of self-consistent determination of charge redistribution, multi-center interactions, and modeling of electron-electron correlation, has taken into account the effect excited on the orbitals due to the atomic aggregation. This important upgrade has been subjected to a stringent test, the construction of the SCED-LCAO Hamiltonian for boron. It was shown that the Hamiltonian for boron has successfully characterized the electron deficiency of boron and captured the complex chemicalmore » bonding in various boron allotropes, including the planar and quasi-planar, the convex, the ring, the icosahedral, and the fullerene-like clusters, the two-dimensional monolayer sheets, and the bulk alpha boron, demonstrating its transferability, robustness, reliability, and predictive power. The molecular dynamics simulation scheme based on the Hamiltonian has been applied to explore the existence and the energetics of ∼230 compact boron clusters B{sub N} with N in the range from ∼100 to 768, including the random, the rhombohedral, and the spherical icosahedral structures. It was found that, energetically, clusters containing whole icosahedral B{sub 12} units are more stable for boron clusters of larger size (N > 200). The ease with which the simulations both at 0 K and finite temperatures were completed is a demonstration of the efficiency of the SCED-LCAO Hamiltonian.« less
NASA Astrophysics Data System (ADS)
Tandy, P.; Yu, Ming; Leahy, C.; Jayanthi, C. S.; Wu, S. Y.
2015-03-01
An upgrade of the previous self-consistent and environment-dependent linear combination of atomic orbitals Hamiltonian (referred as SCED-LCAO) has been developed. This improved version of the semi-empirical SCED-LCAO Hamiltonian, in addition to the inclusion of self-consistent determination of charge redistribution, multi-center interactions, and modeling of electron-electron correlation, has taken into account the effect excited on the orbitals due to the atomic aggregation. This important upgrade has been subjected to a stringent test, the construction of the SCED-LCAO Hamiltonian for boron. It was shown that the Hamiltonian for boron has successfully characterized the electron deficiency of boron and captured the complex chemical bonding in various boron allotropes, including the planar and quasi-planar, the convex, the ring, the icosahedral, and the fullerene-like clusters, the two-dimensional monolayer sheets, and the bulk alpha boron, demonstrating its transferability, robustness, reliability, and predictive power. The molecular dynamics simulation scheme based on the Hamiltonian has been applied to explore the existence and the energetics of ˜230 compact boron clusters BN with N in the range from ˜100 to 768, including the random, the rhombohedral, and the spherical icosahedral structures. It was found that, energetically, clusters containing whole icosahedral B12 units are more stable for boron clusters of larger size (N > 200). The ease with which the simulations both at 0 K and finite temperatures were completed is a demonstration of the efficiency of the SCED-LCAO Hamiltonian.
Quantum stream instability in coupled two-dimensional plasmas
NASA Astrophysics Data System (ADS)
Akbari-Moghanjoughi, M.
2014-08-01
In this paper the quantum counter-streaming instability problem is studied in planar two-dimensional (2D) quantum plasmas using the coupled quantum hydrodynamic (CQHD) model which incorporates the most important quantum features such as the statistical Fermi-Dirac electron pressure, the electron-exchange potential and the quantum diffraction effect. The instability is investigated for different 2D quantum electron systems using the dynamics of Coulomb-coupled carriers on each plasma sheet when these plasmas are both monolayer doped graphene or metalfilm (corresponding to 2D Dirac or Fermi electron fluids). It is revealed that there are fundamental differences between these two cases regarding the effects of Bohm's quantum potential and the electron-exchange on the instability criteria. These differences mark yet another interesting feature of the effect of the energy band dispersion of Dirac electrons in graphene. Moreover, the effects of plasma number-density and coupling parameter on the instability criteria are shown to be significant. This study is most relevant to low dimensional graphene-based field-effect-transistor (FET) devices. The current study helps in understanding the collective interactions of the low-dimensional coupled ballistic conductors and the nanofabrication of future graphene-based integrated circuits.
Sarrazin, Samuel; Poupon, Cyril; Linke, Julia; Wessa, Michèle; Phillips, Mary; Delavest, Marine; Versace, Amelia; Almeida, Jorge; Guevara, Pamela; Duclap, Delphine; Duchesnay, Edouard; Mangin, Jean-François; Le Dudal, Katia; Daban, Claire; Hamdani, Nora; D'Albis, Marc-Antoine; Leboyer, Marion; Houenou, Josselin
2014-04-01
Tractography studies investigating white matter (WM) abnormalities in patients with bipolar disorder have yielded heterogeneous results owing to small sample sizes. The small size limits their generalizability, a critical issue for neuroimaging studies of biomarkers of bipolar I disorder (BPI). To study WM abnormalities using whole-brain tractography in a large international multicenter sample of BPI patients and to compare these alterations between patients with or without a history of psychotic features during mood episodes. A cross-sectional, multicenter, international, Q-ball imaging tractography study comparing 118 BPI patients and 86 healthy control individuals. In addition, among the patient group, we compared those with and without a history of psychotic features. University hospitals in France, Germany, and the United States contributed participants. Participants underwent assessment using the Diagnostic Interview for Genetic Studies at the French sites or the Structured Clinical Interview for DSM-IV at the German and US sites. Diffusion-weighted magnetic resonance images were acquired using the same acquisition parameters and scanning hardware at each site. We reconstructed 22 known deep WM tracts using Q-ball imaging tractography and an automatized segmentation technique. Generalized fractional anisotropy values along each reconstructed WM tract. Compared with controls, BPI patients had significant reductions in mean generalized fractional anisotropy values along the body and the splenium of the corpus callosum, the left cingulum, and the anterior part of the left arcuate fasciculus when controlling for age, sex, and acquisition site (corrected for multiple testing). Patients with a history of psychotic features had a lower mean generalized fractional anisotropy value than those without along the body of the corpus callosum (corrected for multiple testing). In this multicenter sample, BPI patients had reduced WM integrity in interhemispheric, limbic, and arcuate WM tracts. Interhemispheric pathways are more disrupted in patients with than in those without psychotic symptoms. Together these results highlight the existence of an anatomic disconnectivity in BPI and further underscore a role for interhemispheric disconnectivity in the pathophysiological features of psychosis in BPI.
NASA Astrophysics Data System (ADS)
Liu, Junzi; Cheng, Lan
2018-04-01
An atomic mean-field (AMF) spin-orbit (SO) approach within exact two-component theory (X2C) is reported, thereby exploiting the exact decoupling scheme of X2C, the one-electron approximation for the scalar-relativistic contributions, the mean-field approximation for the treatment of the two-electron SO contribution, and the local nature of the SO interactions. The Hamiltonian of the proposed SOX2CAMF scheme comprises the one-electron X2C Hamiltonian, the instantaneous two-electron Coulomb interaction, and an AMF SO term derived from spherically averaged Dirac-Coulomb Hartree-Fock calculations of atoms; no molecular relativistic two-electron integrals are required. Benchmark calculations for bond lengths, harmonic frequencies, dipole moments, and electric-field gradients for a set of diatomic molecules containing elements across the periodic table show that the SOX2CAMF scheme offers a balanced treatment for SO and scalar-relativistic effects and appears to be a promising candidate for applications to heavy-element containing systems. SOX2CAMF coupled-cluster calculations of molecular properties for bismuth compounds (BiN, BiP, BiF, BiCl, and BiI) are also presented and compared with experimental results to further demonstrate the accuracy and applicability of the SOX2CAMF scheme.
Integrated electronics and fluidic MEMS for bioengineering
NASA Astrophysics Data System (ADS)
Fok, Ho Him Raymond
Microelectromechanical systems (MEMS) and microelectronics have become enabling technologies for many research areas. This dissertation presents the use of fluidic MEMS and microelectronics for bioengineering applications. In particular, the versatility of MEMS and microelectronics is highlighted by the presentation of two different applications, one for in-vitro study of nano-scale dynamics during cell division and one for in-vivo monitoring of biological activities at the cellular level. The first application of an integrated system discussed in this dissertation is to utilize fluidic MEMS for studying dynamics in the mitotic spindle, which could lead to better chemotherapeutic treatments for cancer patients. Previous work has developed the use of electrokinetic phenomena on the surface of a glass-based platform to assemble microtubules, the building blocks of mitotic spindles. Nevertheless, there are two important limitations of this type of platform. First, an unconventional microfabrication process is necessary for the glass-based platform, which limits the utility of this platform. In order to overcome this limitation, in this dissertation a convenient microfluidic system is fabricated using a negative photoresist called SU-8. The fabrication process for the SU-8-based system is compatible with other fabrication techniques used in developing microelectronics, and this compatibility is essential for integrating electronics for studying dynamics in the mitotic spindle. The second limitation of the previously-developed glass-based platform is its lack of bio-compatibility. For example, microtubules strongly interact with the surface of the glass-based platform, thereby hindering the study of dynamics in the mitotic spindle. This dissertation presents a novel approach for assembling microtubules away from the surface of the platform, and a fabrication process is developed to assemble microtubules between two self-aligned thin film electrodes on thick SU-8 pedestals. This approach also allows the in-vitro model to mimic the three-dimensionality of the cellular mitotic spindle that is absent in previous work. The second application of an integrated bioengineering system discussed in this dissertation is to design and fabricate active electronics and sensors for an in-vivo application to monitor neural activity at the cellular level. Temperature sensors were chosen for a first demonstration. In order for temperature sensors to be able to be implanted into brain interfaces, it is necessary for these devices to be fabricated using processes that are compatible with bio-compatible substrates such as glass and plastic. This dissertation addresses this challenge by developing temperature sensors integrated with biasing circuitry using zinc oxide thin film transistors (TFTs) fabricated on polyimide substrates. The integrated sensors show good temperature sensitivity, which is critical for monitoring neural temperature at the cellular level. This dissertation also describes the unique requirements of encapsulating implantable electronics. For instance, encapsulation schemes must be designed in such a way that they both protect electronic devices from extracellular fluids and also do not interfere with the functionality of these devices. In this work, SU-8 is used as a convenient and effective encapsulation layer. Thermal engineering to prevent active electronics from overheating and to ensure accurate temperature measurement from temperature sensors is also discussed, and a synergistic encapsulation and thermal engineering combination is presented.
Dutch virtual integration of healthcare information.
de Graaf, J C; Vlug, A E; van Boven, G J
2007-01-01
As information technology creates opportunities for cooperation which crosses the boundaries between healthcare institutions, it will become an integral part of the Dutch healthcare system. Along with many involved organizations in healthcare the National IT Institute for Healthcare in the Netherlands (NICTIZ) is working on the realization of a national IT infrastructure for healthcare and a national electronic patient record (EPR). An underlying national architecture is designed to enable the Dutch EPR virtually, not in a national database, nor on a patient's smartcard. The required secure infrastructure provides generic functions for healthcare applications: patient identification, authentication and authorization of healthcare professionals. The first national applications in the EPR program using a national index of where patient data is stored, are the electronic medication record and the electronic record for after hours GP services. The rollout of the electronic medication record and electronic record for after hours GP services has been started in 2007. To guarantee progress of electronic data exchange in healthcare in the Netherlands we have primarily opted for two healthcare applications: the electronic medication record and the electronic record for after hours GP services. The use of a national switch-point containing the registry of where to find what information, guarantees that the professional receives the most recent information and omits large databases to contain downloaded data. Proper authorization, authentication as well as tracing by the national switchpoint also ensures a secure environment for the communication of delicate information.
Eminaga, O; Semjonow, A; Oezguer, E; Herden, J; Akbarov, I; Tok, A; Engelmann, U; Wille, S
2014-01-01
The integrity of collection protocols in biobanking is essential for a high-quality sample preparation process. However, there is not currently a well-defined universal method for integrating collection protocols in the biobanking information system (BIMS). Therefore, an electronic schema of the collection protocol that is based on Extensible Markup Language (XML) is required to maintain the integrity and enable the exchange of collection protocols. The development and implementation of an electronic specimen collection protocol schema (eSCPS) was performed at two institutions (Muenster and Cologne) in three stages. First, we analyzed the infrastructure that was already established at both the biorepository and the hospital information systems of these institutions and determined the requirements for the sufficient preparation of specimens and documentation. Second, we designed an eSCPS according to these requirements. Finally, a prospective study was conducted to implement and evaluate the novel schema in the current BIMS. We designed an eSCPS that provides all of the relevant information about collection protocols. Ten electronic collection protocols were generated using the supplementary Protocol Editor tool, and these protocols were successfully implemented in the existing BIMS. Moreover, an electronic list of collection protocols for the current studies being performed at each institution was included, new collection protocols were added, and the existing protocols were redesigned to be modifiable. The documentation time was significantly reduced after implementing the eSCPS (5 ± 2 min vs. 7 ± 3 min; p = 0.0002). The eSCPS improves the integrity and facilitates the exchange of specimen collection protocols in the existing open-source BIMS.
Hydrodynamic Instability, Integrated Code, Laboratory Astrophysics, and Astrophysics
NASA Astrophysics Data System (ADS)
Takabe, Hideaki
2016-10-01
This is an article for the memorial lecture of Edward Teller Medal and is presented as memorial lecture at the IFSA03 conference held on September 12th, 2003, at Monterey, CA. The author focuses on his main contributions to fusion science and its extension to astrophysics in the field of theory and computation by picking up five topics. The first one is the anomalous resisitivity to hot electrons penetrating over-dense region through the ion wave turbulence driven by the return current compensating the current flow by the hot electrons. It is concluded that almost the same value of potential as the average kinetic energy of the hot electrons is realized to prevent the penetration of the hot electrons. The second is the ablative stabilization of Rayleigh-Taylor instability at ablation front and its dispersion relation so-called Takabe formula. This formula gave a principal guideline for stable target design. The author has developed an integrated code ILESTA (ID & 2D) for analyses and design of laser produced plasma including implosion dynamics. It is also applied to design high gain targets. The third is the development of the integrated code ILESTA. The forth is on Laboratory Astrophysics with intense lasers. This consists of two parts; one is review on its historical background and the other is on how we relate laser plasma to wide-ranging astrophysics and the purposes for promoting such research. In relation to one purpose, I gave a comment on anomalous transport of relativistic electrons in Fast Ignition laser fusion scheme. Finally, I briefly summarize recent activity in relation to application of the author's experience to the development of an integrated code for studying extreme phenomena in astrophysics.
NASA Astrophysics Data System (ADS)
Molinari, Filippo; Acharya, Rajendra; Zeng, Guang; Suri, Jasjit S.
2011-03-01
The carotid intima-media thickness (IMT) is the most used marker for the progression of atherosclerosis and onset of the cardiovascular diseases. Computer-aided measurements improve accuracy, but usually require user interaction. In this paper we characterized a new and completely automated technique for carotid segmentation and IMT measurement based on the merits of two previously developed techniques. We used an integrated approach of intelligent image feature extraction and line fitting for automatically locating the carotid artery in the image frame, followed by wall interfaces extraction based on Gaussian edge operator. We called our system - CARES. We validated the CARES on a multi-institutional database of 300 carotid ultrasound images. IMT measurement bias was 0.032 +/- 0.141 mm, better than other automated techniques and comparable to that of user-driven methodologies. Our novel approach of CARES processed 96% of the images leading to the figure of merit to be 95.7%. CARES ensured complete automation and high accuracy in IMT measurement; hence it could be a suitable clinical tool for processing of large datasets in multicenter studies involving atherosclerosis.pre-
Atomic-batched tensor decomposed two-electron repulsion integrals
NASA Astrophysics Data System (ADS)
Schmitz, Gunnar; Madsen, Niels Kristian; Christiansen, Ove
2017-04-01
We present a new integral format for 4-index electron repulsion integrals, in which several strategies like the Resolution-of-the-Identity (RI) approximation and other more general tensor-decomposition techniques are combined with an atomic batching scheme. The 3-index RI integral tensor is divided into sub-tensors defined by atom pairs on which we perform an accelerated decomposition to the canonical product (CP) format. In a first step, the RI integrals are decomposed to a high-rank CP-like format by repeated singular value decompositions followed by a rank reduction, which uses a Tucker decomposition as an intermediate step to lower the prefactor of the algorithm. After decomposing the RI sub-tensors (within the Coulomb metric), they can be reassembled to the full decomposed tensor (RC approach) or the atomic batched format can be maintained (ABC approach). In the first case, the integrals are very similar to the well-known tensor hypercontraction integral format, which gained some attraction in recent years since it allows for quartic scaling implementations of MP2 and some coupled cluster methods. On the MP2 level, the RC and ABC approaches are compared concerning efficiency and storage requirements. Furthermore, the overall accuracy of this approach is assessed. Initial test calculations show a good accuracy and that it is not limited to small systems.
Atomic-batched tensor decomposed two-electron repulsion integrals.
Schmitz, Gunnar; Madsen, Niels Kristian; Christiansen, Ove
2017-04-07
We present a new integral format for 4-index electron repulsion integrals, in which several strategies like the Resolution-of-the-Identity (RI) approximation and other more general tensor-decomposition techniques are combined with an atomic batching scheme. The 3-index RI integral tensor is divided into sub-tensors defined by atom pairs on which we perform an accelerated decomposition to the canonical product (CP) format. In a first step, the RI integrals are decomposed to a high-rank CP-like format by repeated singular value decompositions followed by a rank reduction, which uses a Tucker decomposition as an intermediate step to lower the prefactor of the algorithm. After decomposing the RI sub-tensors (within the Coulomb metric), they can be reassembled to the full decomposed tensor (RC approach) or the atomic batched format can be maintained (ABC approach). In the first case, the integrals are very similar to the well-known tensor hypercontraction integral format, which gained some attraction in recent years since it allows for quartic scaling implementations of MP2 and some coupled cluster methods. On the MP2 level, the RC and ABC approaches are compared concerning efficiency and storage requirements. Furthermore, the overall accuracy of this approach is assessed. Initial test calculations show a good accuracy and that it is not limited to small systems.
Electronic photography at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Holm, Jack M.
1994-01-01
The field of photography began a metamorphosis several years ago which promises to fundamentally change how images are captured, transmitted, and output. At this time the metamorphosis is still in the early stages, but already new processes, hardware, and software are allowing many individuals and organizations to explore the entry of imaging into the information revolution. Exploration at this time is prerequisite to leading expertise in the future, and a number of branches at LaRC have ventured into electronic and digital imaging. Their progress until recently has been limited by two factors: the lack of an integrated approach and the lack of an electronic photographic capability. The purpose of the research conducted was to address these two items. In some respects, the lack of electronic photographs has prevented application of an integrated imaging approach. Since everything could not be electronic, the tendency was to work with hard copy. Over the summer, the Photographics Section has set up an Electronic Photography Laboratory. This laboratory now has the capability to scan film images, process the images, and output the images in a variety of forms. Future plans also include electronic capture capability. The current forms of image processing available include sharpening, noise reduction, dust removal, tone correction, color balancing, image editing, cropping, electronic separations, and halftoning. Output choices include customer specified electronic file formats which can be output on magnetic or optical disks or over the network, 4400 line photographic quality prints and transparencies to 8.5 by 11 inches, and 8000 line film negatives and transparencies to 4 by 5 inches. The problem of integrated imaging involves a number of branches at LaRC including Visual Imaging, Research Printing and Publishing, Data Visualization and Animation, Advanced Computing, and various research groups. These units must work together to develop common approaches to image processing and archiving. The ultimate goal is to be able to search for images using an on-line database and image catalog. These images could then be retrieved over the network as needed, along with information on the acquisition and processing prior to storage. For this goal to be realized, a number of standard processing protocols must be developed to allow the classification of images into categories. Standard series of processing algorithms can then be applied to each category (although many of these may be adaptive between images). Since the archived image files would be standardized, it should also be possible to develop standard output processing protocols for a number of output devices. If LaRC continues the research effort begun this summer, it may be one of the first organizations to develop an integrated approach to imaging. As such, it could serve as a model for other organizations in government and the private sector.
Nga Ng, Tse; Schwartz, David E.; Mei, Ping; Krusor, Brent; Kor, Sivkheng; Veres, Janos; Bröms, Per; Eriksson, Torbjörn; Wang, Yong; Hagel, Olle; Karlsson, Christer
2015-01-01
We have demonstrated a printed electronic tag that monitors time-integrated sensor signals and writes to nonvolatile memories for later readout. The tag is additively fabricated on flexible plastic foil and comprises a thermistor divider, complementary organic circuits, and two nonvolatile memory cells. With a supply voltage below 30 V, the threshold temperatures can be tuned between 0 °C and 80 °C. The time-temperature dose measurement is calibrated for minute-scale integration. The two memory bits are sequentially written in a thermometer code to provide an accumulated dose record. PMID:26307438
Khuri-Yakub, B. (Pierre) T.; Oralkan, Ömer; Nikoozadeh, Amin; Wygant, Ira O.; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N.; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O’Donnell, Matthew; Truong, Uyen; Sahn, David J.
2010-01-01
Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics. PMID:21097106
Discovery and validation of cell cycle arrest biomarkers in human acute kidney injury
2013-01-01
Introduction Acute kidney injury (AKI) can evolve quickly and clinical measures of function often fail to detect AKI at a time when interventions are likely to provide benefit. Identifying early markers of kidney damage has been difficult due to the complex nature of human AKI, in which multiple etiologies exist. The objective of this study was to identify and validate novel biomarkers of AKI. Methods We performed two multicenter observational studies in critically ill patients at risk for AKI - discovery and validation. The top two markers from discovery were validated in a second study (Sapphire) and compared to a number of previously described biomarkers. In the discovery phase, we enrolled 522 adults in three distinct cohorts including patients with sepsis, shock, major surgery, and trauma and examined over 300 markers. In the Sapphire validation study, we enrolled 744 adult subjects with critical illness and without evidence of AKI at enrollment; the final analysis cohort was a heterogeneous sample of 728 critically ill patients. The primary endpoint was moderate to severe AKI (KDIGO stage 2 to 3) within 12 hours of sample collection. Results Moderate to severe AKI occurred in 14% of Sapphire subjects. The two top biomarkers from discovery were validated. Urine insulin-like growth factor-binding protein 7 (IGFBP7) and tissue inhibitor of metalloproteinases-2 (TIMP-2), both inducers of G1 cell cycle arrest, a key mechanism implicated in AKI, together demonstrated an AUC of 0.80 (0.76 and 0.79 alone). Urine [TIMP-2]·[IGFBP7] was significantly superior to all previously described markers of AKI (P <0.002), none of which achieved an AUC >0.72. Furthermore, [TIMP-2]·[IGFBP7] significantly improved risk stratification when added to a nine-variable clinical model when analyzed using Cox proportional hazards model, generalized estimating equation, integrated discrimination improvement or net reclassification improvement. Finally, in sensitivity analyses [TIMP-2]·[IGFBP7] remained significant and superior to all other markers regardless of changes in reference creatinine method. Conclusions Two novel markers for AKI have been identified and validated in independent multicenter cohorts. Both markers are superior to existing markers, provide additional information over clinical variables and add mechanistic insight into AKI. Trial registration ClinicalTrials.gov number NCT01209169. PMID:23388612
The opportunities for and challenges of common integrated electronics
NASA Astrophysics Data System (ADS)
Nelson, J. R.; Retterer, Bernard L.; Cloud, Harley A.
1994-02-01
This document summarizes a portion of IDA's work concerning common integrated electronics and the potential cost savings of using common electronic hardware and software. It addresses trends in avionics costs and recent experiences in applying common electronic standards to weapon programs as a way to reduce costs. The following essential elements of a program to acquire common integrated electronics are explored: (1) integrated system architecture; (2) advanced technology programs; (3) open system standards; (4) standard common modules; and (5) associated management and policies. The principal recommendation is that OSD support and coordinate such a-program by taking a strong leadership role and setting standards policy.
Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.
Plaza, Vicente; Fernández-Rodríguez, Concepción; Melero, Carlos; Cosío, Borja G; Entrenas, Luís Manuel; de Llano, Luis Pérez; Gutiérrez-Pereyra, Fernando; Tarragona, Eduard; Palomino, Rosa; López-Viña, Antolín
2016-04-01
To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were defined as adherents. Construct validity, internal validity, and criterion validity were evaluated. Self-reported adherence was compared with the Morisky-Green questionnaire. Factor analysis study demonstrated two factors, factor 1 was coincident with TAI patient domain (items 1 to 10) and factor 2 with TAI health-care professional domain (items 11 and 12). The Cronbach's alpha was 0.860 and the test-retest reliability 0.883. TAI scores correlated with electronic adherence (ρ=0.293, p=0.01). According to the best cut-off for 10 items (score 50, area under the ROC curve 0.7), 569 (62.5%) patients were classified as non-adherents. The non-adherence behavior pattern was: erratic 527 (57.9%), deliberate 375 (41.2%), and unwitting 242 (26.6%) patients. As compared to Morisky-Green test, TAI showed better psychometric properties. The TAI is a reliable and homogeneous questionnaire to identify easily non-adherence and to classify from a clinical perspective the barriers related to the use of inhalers in asthma and COPD.
Few-layer molybdenum disulfide transistors and circuits for high-speed flexible electronics.
Cheng, Rui; Jiang, Shan; Chen, Yu; Liu, Yuan; Weiss, Nathan; Cheng, Hung-Chieh; Wu, Hao; Huang, Yu; Duan, Xiangfeng
2014-10-08
Two-dimensional layered materials, such as molybdenum disulfide, are emerging as an exciting material system for future electronics due to their unique electronic properties and atomically thin geometry. Here we report a systematic investigation of MoS2 transistors with optimized contact and device geometry, to achieve self-aligned devices with performance including an intrinsic gain over 30, an intrinsic cut-off frequency fT up to 42 GHz and a maximum oscillation frequency fMAX up to 50 GHz, exceeding the reported values for MoS2 transistors to date (fT~0.9 GHz, fMAX~1 GHz). Our results show that logic inverters or radio frequency amplifiers can be formed by integrating multiple MoS2 transistors on quartz or flexible substrates with voltage gain in the gigahertz regime. This study demonstrates the potential of two-dimensional layered semiconductors for high-speed flexible electronics.
Few-layer molybdenum disulfide transistors and circuits for high-speed flexible electronics
Cheng, Rui; Jiang, Shan; Chen, Yu; Liu, Yuan; Weiss, Nathan; Cheng, Hung-Chieh; Wu, Hao; Huang, Yu; Duan, Xiangfeng
2014-01-01
Two-dimensional layered materials, such as molybdenum disulfide, are emerging as an exciting material system for future electronics due to their unique electronic properties and atomically thin geometry. Here we report a systematic investigation of MoS2 transistors with optimized contact and device geometry, to achieve self-aligned devices with performance including an intrinsic gain over 30, an intrinsic cut-off frequency fT up to 42 GHz and a maximum oscillation frequency fMAX up to 50 GHz, exceeding the reported values for MoS2 transistors to date (fT ~ 0.9 GHz, fMAX ~ 1 GHz). Our results show that logic inverters or radio frequency amplifiers can be formed by integrating multiple MoS2 transistors on quartz or flexible substrates with voltage gain in the gigahertz regime. This study demonstrates the potential of two-dimensional layered semiconductors for high-speed flexible electronics. PMID:25295573
Reinhardt, Martin; Brandmaier, Philipp; Seider, Daniel; Kolesnik, Marina; Jenniskens, Sjoerd; Sequeiros, Roberto Blanco; Eibisberger, Martin; Voglreiter, Philip; Flanagan, Ronan; Mariappan, Panchatcharam; Busse, Harald; Moche, Michael
2017-12-01
Radio-frequency ablation (RFA) is a promising minimal-invasive treatment option for early liver cancer, however monitoring or predicting the size of the resulting tissue necrosis during the RFA-procedure is a challenging task, potentially resulting in a significant rate of under- or over treatments. Currently there is no reliable lesion size prediction method commercially available. ClinicIMPPACT is designed as multicenter-, prospective-, non-randomized clinical trial to evaluate the accuracy and efficiency of innovative planning and simulation software. 60 patients with early liver cancer will be included at four European clinical institutions and treated with the same RFA system. The preinterventional imaging datasets will be used for computational planning of the RFA treatment. All ablations will be simulated simultaneously to the actual RFA procedure, using the software environment developed in this project. The primary outcome measure is the comparison of the simulated ablation zones with the true lesions shown in follow-up imaging after one month, to assess accuracy of the lesion prediction. This unique multicenter clinical trial aims at the clinical integration of a dedicated software solution to accurately predict lesion size and shape after radiofrequency ablation of liver tumors. Accelerated and optimized workflow integration, and real-time intraoperative image processing, as well as inclusion of patient specific information, e.g. organ perfusion and registration of the real RFA needle position might make the introduced software a powerful tool for interventional radiologists to optimize patient outcomes.
Single-Molecule Interfacial Electron Transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ho, Wilson
Interfacial electron transfer (ET) plays an important role in many chemical and biological processes. Specifically, interfacial ET in TiO 2-based systems is important to solar energy technology, catalysis, and environmental remediation technology. However, the microscopic mechanism of interfacial ET is not well understood with regard to atomic surface structure, molecular structure, bonding, orientation, and motion. In this project, we used two complementary methodologies; single-molecule fluorescence spectroscopy, and scanning-tunneling microscopy and spectroscopy (STM and STS) to address this scientific need. The goal of this project was to integrate these techniques and measure the molecular dependence of ET between adsorbed molecules andmore » TiO 2 semiconductor surfaces and the ET induced reactions such as the splitting of water. The scanning probe techniques, STM and STS, are capable of providing the highest spatial resolution but not easily time-resolved data. Single-molecule fluorescence spectroscopy is capable of good time resolution but requires further development to match the spatial resolution of the STM. The integrated approach involving Peter Lu at Bowling Green State University (BGSU) and Wilson Ho at the University of California, Irvine (UC Irvine) produced methods for time and spatially resolved chemical imaging of interfacial electron transfer dynamics and photocatalytic reactions. An integral aspect of the joint research was a significant exchange of graduate students to work at the two institutions. This project bridged complementary approaches to investigate a set of common problems by working with the same molecules on a variety of solid surfaces, but using appropriate techniques to probe under ambient (BGSU) and ultrahigh vacuum (UCI) conditions. The molecular level understanding of the fundamental interfacial electron transfer processes obtained in this joint project will be important for developing efficient light harvesting, solar energy conversion, and broadly applicable to problems in interface chemistry and surface physics.« less
Nurses' Needs for Care Robots in Integrated Nursing Care Services.
Lee, Jai-Yon; Song, Young Ae; Jung, Ji Young; Kim, Hyun Jeong; Kim, Bo Ram; Do, Hyun-Kyung; Lim, Jae-Young
2018-05-13
To determine the need for care robots among nurses and to suggest how robotic care should be prioritized in an integrated nursing care services. Korea is expected to be a super-aged society by 2030. To solve care issues with elderly inpatient caused by informal caregivers, the government introduced 'integrated nursing care services'; these are comprehensive care systems staffed by professionally trained nurses. To assist them, a care robot development project has been launched. The study applied a cross-sectional survey. In 2016, we conducted a multi-center survey involving 302 registered nurses in five hospitals including three tertiary and two secondary hospitals in Korea. The questionnaire consisted of general characteristics of nurses and their views on and extents of agreement about issues associated with robotic care. Trial center nurses and those with ≥10 years of experience reported positively on the prospects for robotic care. The top three desired primary roles for care robots were 'measuring/monitoring', 'mobility/activity' and 'safety care'. 'Reduction in workload', especially in terms of 'other nursing services' which were categorized as non-value-added nursing activities, was the most valued feature. The nurses approved of the aid by care robots but were concerned about device malfunction and interruption of rapport with patients. Care robots are expected to be effective in integrated nursing care services, particularly in 'measuring/monitoring'. Such robots should decrease nurses' workload and minimize non-value-added nursing activities efficiently. No matter how excellent care robots are, they must co-operate with and be controlled by nurses. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Beltrami, Matteo; Palazzuoli, Alberto; Padeletti, Luigi; Cerbai, Elisabetta; Coiro, Stefano; Emdin, Michele; Marcucci, Rossella; Morrone, Doralisa; Cameli, Matteo; Savino, Ketty; Pedrinelli, Roberto; Ambrosio, Giuseppe
2018-02-01
Functional analysis and measurement of left atrium are an integral part of cardiac evaluation, and they represent a key element during non-invasive analysis of diastolic function in patients with hypertension (HT) and/or heart failure with preserved ejection fraction (HFpEF). However, diastolic dysfunction remains quite elusive regarding classification, and atrial size and function are two key factors for left ventricular (LV) filling evaluation. Chronic left atrial (LA) remodelling is the final step of chronic intra-cavitary pressure overload, and it accompanies increased neurohormonal, proarrhythmic and prothrombotic activities. In this systematic review, we aim to purpose a multi-modality approach for LA geometry and function analysis, which integrates diastolic flow with LA characteristics and remodelling through application of both traditional and new diagnostic tools. The most important studies published in the literature on LA size, function and diastolic dysfunction in patients with HFpEF, HT and/or atrial fibrillation (AF) are considered and discussed. In HFpEF and HT, pulsed and tissue Doppler assessments are useful tools to estimate LV filling pressure, atrio-ventricular coupling and LV relaxation but they need to be enriched with LA evaluation in terms of morphology and function. An integrated evaluation should be also applied to patients with a high arrhythmic risk, in whom eccentric LA remodelling and higher LA stiffness are associated with a greater AF risk. Evaluation of LA size, volume, function and structure are mandatory in the management of patients with HT, HFpEF and AF. A multi-modality approach could provide additional information, identifying subjects with more severe LA remodelling. Left atrium assessment deserves an accurate study inside the cardiac imaging approach and optimised measurement with established cut-offs need to be better recognised through multicenter studies. © 2017 John Wiley & Sons Ltd.
Study of the Polarization Strategy for Electron Cyclotron Heating Systems on HL-2M
NASA Astrophysics Data System (ADS)
Zhang, F.; Huang, M.; Xia, D. H.; Song, S. D.; Wang, J. Q.; Huang, B.; Wang, H.
2016-06-01
As important components integrated in transmission lines of electron cyclotron heating systems, polarizers are mainly used to obtain the desired polarization for highly efficient coupling between electron cyclotron waves and plasma. The polarization strategy for 105-GHz electron cyclotron heating systems of HL-2M tokamak is studied in this paper. Considering the polarizers need high efficiency, stability, and low loss to realize any polarization states, two sinusoidal-grooved polarizers, which include a linear polarizer and an elliptical polarizer, are designed with the coordinate transformation method. The parameters, the period p and the depth d, of two sinusoidal-grooved polarizers are optimized by a phase difference analysis method to achieve an almost arbitrary polarization. Finally, the optimized polarizers are manufactured and their polarization characteristics are tested with a low-power test platform. The experimental results agree well with the numerical calculations, indicating that the designed polarizers can meet the polarization requirements of the electron cyclotron heating systems of HL-2M tokamak.
Resonant tunneling device with two-dimensional quantum well emitter and base layers
Simmons, J.A.; Sherwin, M.E.; Drummond, T.J.; Weckwerth, M.V.
1998-10-20
A double electron layer tunneling device is presented. Electrons tunnel from a two dimensional emitter layer to a two dimensional tunneling layer and continue traveling to a collector at a lower voltage. The emitter layer is interrupted by an isolation etch, a depletion gate, or an ion implant to prevent electrons from traveling from the source along the emitter to the drain. The collector is similarly interrupted by a backgate, an isolation etch, or an ion implant. When the device is used as a transistor, a control gate is added to control the allowed energy states of the emitter layer. The tunnel gate may be recessed to change the operating range of the device and allow for integrated complementary devices. Methods of forming the device are also set forth, utilizing epoxy-bond and stop etch (EBASE), pre-growth implantation of the backgate or post-growth implantation. 43 figs.
Resonant tunneling device with two-dimensional quantum well emitter and base layers
Simmons, Jerry A.; Sherwin, Marc E.; Drummond, Timothy J.; Weckwerth, Mark V.
1998-01-01
A double electron layer tunneling device is presented. Electrons tunnel from a two dimensional emitter layer to a two dimensional tunneling layer and continue traveling to a collector at a lower voltage. The emitter layer is interrupted by an isolation etch, a depletion gate, or an ion implant to prevent electrons from traveling from the source along the emitter to the drain. The collector is similarly interrupted by a backgate, an isolation etch, or an ion implant. When the device is used as a transistor, a control gate is added to control the allowed energy states of the emitter layer. The tunnel gate may be recessed to change the operating range of the device and allow for integrated complementary devices. Methods of forming the device are also set forth, utilizing epoxy-bond and stop etch (EBASE), pre-growth implantation of the backgate or post-growth implantation.
Integrating Genomic Resources with Electronic Health Records using the HL7 Infobutton Standard
Overby, Casey Lynnette; Del Fiol, Guilherme; Rubinstein, Wendy S.; Maglott, Donna R.; Nelson, Tristan H.; Milosavljevic, Aleksandar; Martin, Christa L.; Goehringer, Scott R.; Freimuth, Robert R.; Williams, Marc S.
2016-01-01
Summary Background The Clinical Genome Resource (ClinGen) Electronic Health Record (EHR) Workgroup aims to integrate ClinGen resources with EHRs. A promising option to enable this integration is through the Health Level Seven (HL7) Infobutton Standard. EHR systems that are certified according to the US Meaningful Use program provide HL7-compliant infobutton capabilities, which can be leveraged to support clinical decision-making in genomics. Objectives To integrate genomic knowledge resources using the HL7 infobutton standard. Two tactics to achieve this objective were: (1) creating an HL7-compliant search interface for ClinGen, and (2) proposing guidance for genomic resources on achieving HL7 Infobutton standard accessibility and compliance. Methods We built a search interface utilizing OpenInfobutton, an open source reference implementation of the HL7 Infobutton standard. ClinGen resources were assessed for readiness towards HL7 compliance. Finally, based upon our experiences we provide recommendations for publishers seeking to achieve HL7 compliance. Results Eight genomic resources and two sub-resources were integrated with the ClinGen search engine via OpenInfobutton and the HL7 infobutton standard. Resources we assessed have varying levels of readiness towards HL7-compliance. Furthermore, we found that adoption of standard terminologies used by EHR systems is the main gap to achieve compliance. Conclusion Genomic resources can be integrated with EHR systems via the HL7 Infobutton standard using OpenInfobutton. Full compliance of genomic resources with the Infobutton standard would further enhance interoperability with EHR systems. PMID:27579472
ERIC Educational Resources Information Center
Wilens, Timothy E.; Gault, Laura M.; Childress, Ann; Kratochvil, Christopher J.; Bensman, Lindsey; Hall, Coleen M.; Olson, Evelyn; Robieson, Weining Z.; Garimella, Tushar S.; Abi-Saab, Walid M.; Apostol, George; Saltarelli, Mario D.
2011-01-01
Objective: To assess the safety and efficacy of ABT-089, a novel alpha[subscript 4]beta[subscript 2] neuronal nicotinic receptor partial agonist, vs. placebo in children with attention-deficit/hyperactivity disorder (ADHD). Method: Two multicenter, randomized, double-blind, placebo-controlled, parallel-group studies of children 6 through 12 years…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Notice Correction; A Multi-Center International Hospital-Based Case-Control Study of Lymphoma in Asia (AsiaLymph) (NCI) The Federal... project titled, ``A multi-center international hospital-based case-control study of lymphoma in Asia (Asia...
Electron collisions with ethylene
NASA Astrophysics Data System (ADS)
Panajotovic, R.; Kitajima, M.; Tanaka, H.; Jelisavcic, M.; Lower, J.; Campbell, L.; Brunger, M. J.; Buckman, S. J.
2003-04-01
We have measured absolute elastic scattering and vibrational excitation cross sections for electron impact on ethylene. The experimental data have been obtained on two different crossed-beam electron spectrometers and they cover the energy range from 1 to 100 eV and scattering angles between 10° and 130°. Both differential (in angle) and energy-dependent cross sections have been measured. The differential cross sections have also been analysed using a molecular phase shift analysis technique in order to derive the integral elastic and elastic momentum transfer cross sections. Comparison is made with earlier data, where available, and also with a number of recent theoretical calculations.
Integrated Nanoscale Nanowire Correlated Electronic Nanosensing Technology (INNOCENT)
2006-06-01
out by characterizing the response of a 7 device to two different but structurally similar viruses, paramyxovirus and influenza A using nanowire devices...modified with antibodies specific for influenza A. Delivery of a solution containing paramyxovirus exhibited only short duration conductance changes
Adjusted regression trend test for a multicenter clinical trial.
Quan, H; Capizzi, T
1999-06-01
Studies using a series of increasing doses of a compound, including a zero dose control, are often conducted to study the effect of the compound on the response of interest. For a one-way design, Tukey et al. (1985, Biometrics 41, 295-301) suggested assessing trend by examining the slopes of regression lines under arithmetic, ordinal, and arithmetic-logarithmic dose scalings. They reported the smallest p-value for the three significance tests on the three slopes for safety assessments. Capizzi et al. (1992, Biometrical Journal 34, 275-289) suggested an adjusted trend test, which adjusts the p-value using a trivariate t-distribution, the joint distribution of the three slope estimators. In this paper, we propose an adjusted regression trend test suitable for two-way designs, particularly for multicenter clinical trials. In a step-down fashion, the proposed trend test can be applied to a multicenter clinical trial to compare each dose with the control. This sequential procedure is a closed testing procedure for a trend alternative. Therefore, it adjusts p-values and maintains experimentwise error rate. Simulation results show that the step-down trend test is overall more powerful than a step-down least significant difference test.
Fontaine, Patricia; Mendenhall, Tai J; Peterson, Kevin; Speedie, Stuart M
2007-01-01
The electronic Primary Care Research Network (ePCRN) enrolled PBRN researchers in a feasibility trial to test the functionality of the network's electronic architecture and investigate error rates associated with two data entry strategies used in clinical trials. PBRN physicians and research assistants who registered with the ePCRN were eligible to participate. After online consent and randomization, participants viewed simulated patient records, presented as either abstracted data (short form) or progress notes (long form). Participants transcribed 50 data elements onto electronic case report forms (CRFs) without integrated field restrictions. Data errors were analyzed. Ten geographically dispersed PBRNs enrolled 100 members and completed the study in less than 7 weeks. The estimated overall error rate if field restrictions had been applied was 2.3%. Participants entering data from the short form had a higher rate of correctly entered data fields (94.5% vs 90.8%, P = .004) and significantly more error-free records (P = .003). Feasibility outcomes integral to completion of an Internet-based, multisite study were successfully achieved. Further development of programmable electronic safeguards is indicated. The error analysis conducted in this study will aid design of specific field restrictions for electronic CRFs, an important component of clinical trial management systems.
2014-02-01
Page 13 GAO-14-302 Electronic Health Records known as the Captain James A. Lovell Federal Health Care Center ( FHCC ). The FHCC is unique in...Healthcare Management System Modernization DOD Department of Defense FHCC Federal Health Care Center FHIE Federal Health Information Exchange GCPR... FHCC and, in accordance with the fiscal year 2010 NDAA, defined the relationship between the two departments for operating the new, integrated
Kavros, Steven J; Dutra, Timothy; Gonzalez-Cruz, Renier; Liden, Brock; Marcus, Belinda; McGuire, James; Nazario-Guirau, Luis
2014-08-01
The objective of this multicenter study was to prospectively evaluate the healing outcomes of chronic diabetic foot ulcers (DFUs) treated with PriMatrix (TEI Biosciences, Boston, Massachusetts), a fetal bovine acellular dermal matrix. Inclusion criteria required the subjects to have a chronic DFU that ranged in area from 1 to 20 cm² and failed to heal more than 30% during a 2-week screening period when treated with moist wound therapy. For qualifying subjects, PriMatrix was secured into a clean, sharply debrided wound; dressings were applied to maintain a moist wound environment, and the DFU was pressure off-loaded. Wound area measurements were taken weekly for up to 12 weeks, and PriMatrix was reapplied at the discretion of the treating physician. A total of 55 subjects were enrolled at 9 US centers with 46 subjects progressing to study completion. Ulcers had been in existence for an average of 286 days, and initial mean ulcer area was 4.34 cm². Of the subjects completing the study, 76% healed by 12 weeks with a mean time to healing of 53.1 ± 21.9 days. The mean number of applications for these healed wounds was 2.0 ± 1.4, with 59.1% healing with a single application of PriMatrix and 22.9% healing with 2 applications. For subjects not healed by 12 weeks, the average wound area reduction was 71.4%. The results of this multicenter prospective study demonstrate that the use of PriMatrix integrated with standard-of-care therapy is a successful treatment regimen to heal DFUs.
Wolk, D. M.; Picton, E.; Johnson, D.; Davis, T.; Pancholi, P.; Ginocchio, C. C.; Finegold, S.; Welch, D. F.; de Boer, M.; Fuller, D.; Solomon, M. C.; Rogers, B.; Mehta, M. S.; Peterson, L. R.
2009-01-01
The first U.S. multicenter clinical trial to assess the performance of the Cepheid Xpert MRSA assay (Xpert MRSA) was conducted. The assay is a qualitative test designed for the rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) directly from nares swabs. This novel test combines integrated nucleic acid extraction and automated real-time PCR for the detection of a MRSA-specific signature sequence. A total of 1,077 nares specimens were collected from seven geographically distinct health care sites across the United States with prevalence rates ranging from 5.2% to 44%. Nares specimens were tested by (i) the Xpert MRSA assay, (ii) direct culture on CHROMagar MRSA medium (direct CM culture), and (iii) broth-enriched culture (Trypticase soy broth with 6.5% sodium chloride) followed by plating onto CHROMagar MRSA medium (broth-enriched CM culture). When direct CM culture was designated the reference method, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the Xpert MRSA assay were 94.3%, 93.2%, 73.0%, and 98.8%, respectively. When broth-enriched CM culture was used as the reference method, the clinical sensitivity, specificity, PPV, and NPV of the Xpert MRSA assay were 86.3%, 94.9%, 80.5%, and 96.6%, respectively. The BD GeneOhm MRSA (BDGO) assay was performed as a comparative molecular method. No statistical performance differences were observed between the Xpert MRSA and BDGO assays when they were compared to culture methods. From this large-scale, multicenter clinical comparison, we conclude that the Xpert MRSA assay is a simple, rapid, and accurate method for performing active surveillance for MRSA in a variety of health care populations. PMID:19129414
Effect of nuclear shielding in collision of positive charged helium ions with helium atoms
NASA Astrophysics Data System (ADS)
Ghavaminia, Hoda; Ghavaminia, Shirin
2018-03-01
Differential in angle and absolute cross sections in energy of the scattered particles are obtained for single charge exchange in ^3He^+-^4He collisions by means of the four body boundary-corrected first Born approximation (CB1-4B). The quantum-mechanical post and prior transition amplitudes are derived in terms of two-dimensional real integrals in the case of the prior form and five-dimensional quadratures for the post form. The effect of the dynamic electron correlation through the complete perturbation potential and the nuclear-screening influence of the passive electrons on the electron capture process is investigated. The results obtained in the CB1-4B method are compared with the available experimental data. For differential cross sections, the present results are in better agreement with experimental data than other theoretical data at extreme forward scattering angles. The integral cross sections are in excellent agreement with the experiment. Also, total cross sections for single electron capture, has been investigated using the classical trajectory Monte Carlo method. The present calculated results are found to be in an excellent agreement with the experimental data.
Renal Replacement Therapy in Severe Burns: A Multicenter Observational Study.
Chung, Kevin K; Coates, Elsa C; Hickerson, William L; Arnold-Ross, Angela L; Caruso, Daniel M; Albrecht, Marlene; Arnoldo, Brett D; Howard, Christina; Johnson, Laura S; McLawhorn, Melissa M; Friedman, Bruce; Sprague, Amy M; Mosier, Michael J; Conrad, Peggie F; Smith, David J; Karlnoski, Rachel A; Aden, James K; Mann-Salinas, Elizabeth A; Wolf, Steven E
2018-06-20
Acute kidney injury (AKI) after severe burns is historically associated with a high mortality. Over the past two decades, various modes of renal replacement therapy (RRT) have been utilized in this population. The purpose of this multicenter study was to evaluate demographic, treatment and outcomes data among severe burn patients treated with RRT collectively at various burn centers around the United States. After institutional review board approval, a multicenter observational study was conducted. All adult patients 18 or older, admitted with severe burns who were placed on RRT for acute indications but not randomized into a concurrently enrolling interventional trial were included. Across 8 participating burn centers, 171 subjects were enrolled during a 4 year period. Complete data was available in 170 subjects with a mean age of 51±17, percent total body surface area (TBSA) burn of 38±26% and Injury Severity Score of 27±21. 80% of subjects were male and 34% were diagnosed with smoke inhalation injury. The preferred mode of therapy was continuous venovenous hemofiltration at a mean delivered dose of 37±19 (mL/kg/hr) and a treatment duration of 13±24 days. Overall, in hospital mortality was 50%. Among survivors, 21% required RRT upon discharge from the hospital while 9% continued to require RRT 6 months after discharge. This is the first multi-center cohort of burn patients who underwent RRT reported to date. Overall mortality is comparable to other critically ill populations who undergo RRT. Most patients who survive to discharge eventually recover renal function.
Léger, Christophe; Lederer, Florence; Guigliarelli, Bruno; Bertrand, Patrick
2006-01-11
In protein film voltammetry, a redox enzyme is directly connected to an electrode; in the presence of substrate and when the driving force provided by the electrode is appropriate, a current flow reveals the steady-state turnover. We show that, in the case of a multicenter enzyme, this signal reports on the energetics and kinetics of electron transfer (ET) along the redox chain that wires the active site to the electrode, and this provides a new strategy for studying intramolecular ET. We propose a model which takes into account all the enzyme's redox microstates, and we prove it useful to interpret data for various enzymes. Several general ideas emerge from this analysis. Considering the reversibility of ET is a requirement: the usual picture, where ET is depicted as a series of irreversible steps, is oversimplified and lacks the important features that we emphasize. We give justification to the concept of apparent reduction potential on the time scale of turnover and we explain how the value of this potential relates to the thermodynamic and kinetic properties of the system. When intramolecular ET does not limit turnover, the redox chain merely mediates the driving force provided by the electrode or the soluble redox partner, whereas when intramolecular ET is slow, the enzyme behaves as if its active active site had apparent redox properties which depend on the reduction potentials of the relays. This suggests an alternative to the idea that redox chains are optimized in terms of speed: evolutionary pressure may have resulted in slowing down intramolecular ET in order to tune the enzyme's "operating potential".
Development, implementation, and compliance of treatment pathways in radiation medicine.
Potters, Louis; Raince, Jadeep; Chou, Henry; Kapur, Ajay; Bulanowski, Daniel; Stanzione, Regina; Lee, Lucille
2013-01-01
While much emphasis on safety in the radiation oncology clinic is placed on process, there remains considerable opportunity to increase safety, enhance outcomes, and avoid ad hoc care by instituting detailed treatment pathways. The purpose of this study was to review the process of developing evidence and consensus-based, outcomes-oriented treatment pathways that standardize treatment and patient management in a large multi-center radiation oncology practice. Further, we reviewed our compliance in incorporating these directives into our day-to-day clinical practice. Using the Institute of Medicine guideline for developing treatment pathways, 87 disease specific pathways were developed and incorporated into the electronic medical system in our multi-facility radiation oncology department. Compliance in incorporating treatment pathways was assessed by mining our electronic medical records (EMR) data from January 1, 2010 through February 2012 for patients with breast and prostate cancer. This retrospective analysis of data from EMR found overall compliance to breast and prostate cancer treatment pathways to be 97 and 99%, respectively. The reason for non-compliance proved to be either a failure to complete the prescribed care based on grade II or III toxicity (n = 1 breast, 3 prostate) or patient elected discontinuance of care (n = 1 prostate) or the physician chose a higher dose for positive/close margins (n = 3 breast). This study demonstrates that consensus and evidence-based treatment pathways can be developed and implemented in a multi-center department of radiation oncology. And that for prostate and breast cancer there was a high degree of compliance using these directives. The development and implementation of these pathways serve as a key component of our safety program, most notably in our effort to facilitate consistent decision-making and reducing variation between physicians.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCurdy, C. William
This project made use of Multiconfiguration Time-Dependent Hartree-Fock method developed earlier in the McCurdy group in a series of novel applications of the method to ultrafast spectroscopic processes. MCTDHF treats the dynamics of a molecule or atom under the influence of an external field in manner that has all electrons active. That property distinguishes this method from the more popular (and much less computationally demanding) approaches for treating the electron dynamics of atoms and molecules in fields, such as the time-dependent “Configuration Interaction Singles” approximation or approaches that limit the treatment to either one or two-electron models.
Review of the results of the in vivo dosimetry during total skin electron beam therapy
Guidi, Gabriele; Gottardi, Giovanni; Ceroni, Paola; Costi, Tiziana
2013-01-01
This work reviews results of in vivo dosimetry (IVD) for total skin electron beam (TSEB) therapy, focusing on new methods, data emerged within 2012. All quoted data are based on a careful review of the literature reporting IVD results for patients treated by means of TSEB therapy. Many of the reviewed papers refer mainly to now old studies and/or old guidelines and recommendations (by IAEA, AAPM and EORTC), because (due to intrinsic rareness of TSEB-treated pathologies) only a limited number of works and reports with a large set of numerical data and proper statistical analysis is up-to-day available in scientific literature. Nonetheless, a general summary of the results obtained by the now numerous IVD techniques available is reported; innovative devices and methods, together with areas of possible further and possibly multicenter investigations for TSEB therapies are highlighted. PMID:24936333
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noll, Daniel; Stancari, Giulio
2015-11-17
An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main design principles and constraints for nonlinear integrable optics. A magnetic configuration of the solenoids and of the toroidal section is laid out. Singleparticle tracking is used to optimize the electron path. Electron beam dynamics at high intensity is calculated with a particle-in-cell code to estimate current limits, profile distortions, and the effects on the circulating beam. In the conclusions, we summarize themore » main findings and list directions for further work.« less
Knowledge integration, teamwork and performance in health care.
Körner, Mirjam; Lippenberger, Corinna; Becker, Sonja; Reichler, Lars; Müller, Christian; Zimmermann, Linda; Rundel, Manfred; Baumeister, Harald
2016-01-01
Knowledge integration is the process of building shared mental models. The integration of the diverse knowledge of the health professions in shared mental models is a precondition for effective teamwork and team performance. As it is known that different groups of health care professionals often tend to work in isolation, the authors compared the perceptions of knowledge integration. It can be expected that based on this isolation, knowledge integration is assessed differently. The purpose of this paper is to test these differences in the perception of knowledge integration between the professional groups and to identify to what extent knowledge integration predicts perceptions of teamwork and team performance and to determine if teamwork has a mediating effect. The study is a multi-center cross-sectional study with a descriptive-explorative design. Data were collected by means of a staff questionnaire for all health care professionals working in the rehabilitation clinics. The results showed that there are significant differences in knowledge integration within interprofessional health care teams. Furthermore, it could be shown that knowledge integration is significantly related to patient-centered teamwork as well as to team performance. Mediation analysis revealed partial mediation of the effect of knowledge integration on team performance through teamwork. PRACTICAL/IMPLICATIONS: In practice, the results of the study provide a valuable starting point for team development interventions. This is the first study that explored knowledge integration in medical rehabilitation teams and its relation to patient-centered teamwork and team performance.
Castilla-Puentes, Ruby C; Secin, Ricardo; Grau, Arturo; Galeno, Roxanna; Feijo de Mello, Marcelo; Pena, Nuri; Sanchez-Russi, Carlos A
2008-01-01
This multicenter study estimated the prevalence of major depressive disorder (MDD) among emergency department patients in Latin America. To identify patients with MDD, we used a combination of DSM IV- criteria interview and a questionnaire screen including the center for Epidemiological Studies Depression Scale. We analyzed data from consecutive adult patients from hospitals in Argentina, Brazil, Chile, Colombia, and Mexico and described the demographic and health status differences between MDD and non-MDD patients. Prevalence of MDD ranges from 23.0 to 35.0%. The estimates are based on a total of 1,835 patients aged 18 years and over, with response rates of 83.0%. Compared to non-MDD patients, MDD patients were more likely to be middle-aged, female, smokers, of lower socioeconomic status, and to report a diagnosis of asthma or arthritis/rheumatism. Multivariate analysis identified a lower level of education, smoking, and self-reported anxiety, chronic fatigue, and back problems to be independently associated with MDD. Our data suggest that the prevalence of MDD is elevated among emergency department patients in Latin American countries. The integration of depression screening into routine emergency care merits serious consideration, especially if such screening can be linked to psychiatric treatment.
Hajek, André; Brettschneider, Christian; Mallon, Tina; van der Leeden, Carolin; Mamone, Silke; Wiese, Birgitt; Weyerer, Siegfried; Werle, Jochen; Fuchs, Angela; Pentzek, Michael; Riedel-Heller, Steffi G; Stein, Janine; Bickel, Horst; Weeg, Dagmar; Heser, Kathrin; Wagner, Michael; Maier, Wolfgang; Scherer, Martin; Luck, Tobias; König, Hans-Helmut
2017-09-01
to investigate how social support affects functional impairment (FI) in late life in a longitudinal approach. in a multicenter prospective cohort study, subjects in old age (≥75 years at baseline) were interviewed every 1.5 years. Social support was quantified in the follow-up (FU) Waves 2 and 4 (FU Wave 2: n = 2,349; FU Wave 4: n = 1,484). FI was assessed by using the Lawton and Brody Instrumental Activities of Daily Living scale. fixed effects regressions showed that a decrease in social support is associated with FI in the total sample and in both sexes. The effect on FI was most pronounced with the dimension social integration, whereas changes in practical support only affected FI in the total sample and changes in emotional support only affected FI in men. our findings emphasise the importance of social support for functional status in late life. Thus, strengthening social support in old age might be effective in maintaining functional abilities. © The Author 2017. Published by Oxford University Press on behalf of the British Geriatrics Society.All rights reserved. For permissions, please email: journals.permissions@oup.com
Cisneros, J M; Viciana, P; Colmenero, J; Pachón, J; Martinez, C; Alarcón, A
1990-01-01
The effectiveness of treating human brucellosis caused by Brucella melitensis with a 6-week course of doxcycline plus streptomycin for 2 of those weeks was analyzed by a multicenter prospective study of 139 patients. Subjects with central nervous system involvement, endocarditis, or spondylitis were excluded from the study. All but 5 of the 139 patients completed the full treatment schedule and became afebrile in the first week of therapy. Four patients suffered relapses during the follow-up period. Of the five patients who did not complete the treatment, two left because of adverse secondary effects (1.4%), another two left for noncomplicance with the treatment (1.4%), and the remaining patient was considered a therapeutic failure because his symptoms persisted after the first week of therapy (0.7%). We concluded that the combination of doxycycline and streptomycin is an effective treatment for the types of brucellosis included in our study. PMID:2193624
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dijkgraaf, Robbert; Gopakumar, Rajesh; Ooguri, Hirosi
We argue that the holographic description of four-dimensional Bogomol'nyi-Prasad-Sommerfield black holes naturally includes multicenter solutions. This suggests that the holographic dual to the gauge theory is not a single AdS{sub 2}xS{sup 2} but a coherent ensemble of them. We verify this in a particular class of examples, where the two-dimensional Yang-Mills theory gives a holographic description of the black holes obtained by branes wrapping Calabi-Yau cycles. Using the free fermionic formulation, we show that O(e{sup -N}) nonperturbative effects entangle the two Fermi surfaces. In an Euclidean description, the wave function of the multicenter black holes gets mapped to the Hartle-Hawkingmore » wave function of baby universes. This provides a concrete realization, within string theory, of effects that can be interpreted as the creation of baby universes. We find that, at least in the case we study, the baby universes do not lead to a loss of quantum coherence, in accord with general arguments.« less
Design of a highly integrated video acquisition module for smart video flight unit development
NASA Astrophysics Data System (ADS)
Lebre, V.; Gasti, W.
2017-11-01
CCD and APS devices are widely used in space missions as instrument sensors and/or in Avionics units like star detectors/trackers. Therefore, various and numerous designs of video acquisition chains have been produced. Basically, a classical video acquisition chain is constituted of two main functional blocks: the Proximity Electronics (PEC), including detector drivers and the Analogue Processing Chain (APC) Electronics that embeds the ADC, a master sequencer and the host interface. Nowadays, low power technologies allow to improve the integration, radiometric performances and power budget optimisation of video units and to standardize video units design and development. To this end, ESA has initiated a development activity through a competitive process requesting the expertise of experienced actors in the field of high resolution electronics for earth observation and Scientific missions. THALES ALENIA SPACE has been granted this activity as a prime contractor through ESA contract called HIVAC that holds for Highly Integrated Video Acquisition Chain. This paper presents main objectives of the on going HIVAC project and focuses on the functionalities and performances offered by the usage of the under development HIVAC board for future optical instruments.
Gill, Ritu R; Naidich, David P; Mitchell, Alan; Ginsberg, Michelle; Erasmus, Jeremy; Armato, Samuel G; Straus, Christopher; Katz, Sharyn; Patios, Demetrois; Richards, William G; Rusch, Valerie W
2016-08-01
Clinical tumor (T), node, and metastasis staging is based on a qualitative assessment of features defining T descriptors and has been found to be suboptimal for predicting the prognosis of patients with malignant pleural mesothelioma (MPM). Previous work suggests that volumetric computed tomography (VolCT) is prognostic and, if found practical and reproducible, could improve clinical MPM classification. Six North American institutions electronically submitted clinical, pathologic, and imaging data on patients with stages I to IV MPM to an established multicenter database and biostatistical center. Two reference radiologists blinded to clinical data independently reviewed the scans; calculated clinical T, node, and metastasis stage by standard criteria; performed semiautomated tumor volume calculations using commercially available software; and submitted the findings to the biostatistical center. Study end points included the feasibility of a multi-institutional VolCT network, concordance of independent VolCT assessments, and association of VolCT with pathological T classification. Of 164 submitted cases, 129 were evaluated by both reference radiologists. Discordant clinical staging of most cases confirmed the inadequacy of current criteria. The overall correlation between VolCT estimates was good (Spearman correlation 0.822), but some were significantly discordant. Root cause analysis of the most discordant estimates identified four common sources of variability. Despite these limitations, median tumor volume estimates were similar within subgroups of cases representing each pathological T descriptor and increased monotonically for each reference radiologist with increasing pathological T status. The good correlation between VolCT estimates obtained for most cases reviewed by two independent radiologists and qualitative association of VolCT with pathological T status combine to encourage further study. The identified sources of user error will inform design of a follow-up prospective trial to more formally assess interobserver variability of VolCT and its potential contribution to clinical MPM staging. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
Sasaki, Akira; Kojo, Masashi; Hirose, Kikuji; Goto, Hidekazu
2011-11-02
The path-integral renormalization group and direct energy minimization method of practical first-principles electronic structure calculations for multi-body systems within the framework of the real-space finite-difference scheme are introduced. These two methods can handle higher dimensional systems with consideration of the correlation effect. Furthermore, they can be easily extended to the multicomponent quantum systems which contain more than two kinds of quantum particles. The key to the present methods is employing linear combinations of nonorthogonal Slater determinants (SDs) as multi-body wavefunctions. As one of the noticeable results, the same accuracy as the variational Monte Carlo method is achieved with a few SDs. This enables us to study the entire ground state consisting of electrons and nuclei without the need to use the Born-Oppenheimer approximation. Recent activities on methodological developments aiming towards practical calculations such as the implementation of auxiliary field for Coulombic interaction, the treatment of the kinetic operator in imaginary-time evolutions, the time-saving double-grid technique for bare-Coulomb atomic potentials and the optimization scheme for minimizing the total-energy functional are also introduced. As test examples, the total energy of the hydrogen molecule, the atomic configuration of the methylene and the electronic structures of two-dimensional quantum dots are calculated, and the accuracy, availability and possibility of the present methods are demonstrated.
NASA Astrophysics Data System (ADS)
Singh, Upendra N.; Petros, Mulugeta; Refaat, Tamer F.; Yu, Jirong; Antill, Charles W.; Taylor, Bryant D.; Bowen, Stephen C.; Welters, Angela M.; Remus, Ruben G.; Wong, Teh-Hwa; Reithmaier, Karl; Lee, Jane; Ismail, Syed
2017-09-01
An airborne 2-μm triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This lidar targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements, simultaneously. Advancements in the development of this IPDA lidar are presented in this paper. Updates on advanced two-micron triple-pulse high-energy laser transmitter will be given including packaging and lidar integration status. In addition, receiver development updates will also be presented. This includes a state-of-the-art detection system integrated at NASA Goddard Space Flight Center. This detection system is based on a newly developed HgCdTe (MCT) electron-initiated avalanche photodiode (e-APD) array. Future plan for IPDA lidar system for ground integration, testing and flight validation will be discussed.
NASA Technical Reports Server (NTRS)
Singh, Upendra N.; Petros, Mulugeta; Refaat, Tamer F.; Yu, Jirong; Antill, Charles W.; Taylor, Bryant D.; Bowen, Stephen C.; Welters, Angela M.; Remus, Ruben G.; Wong, Teh-Hwa;
2014-01-01
An airborne 2 micron triple-pulse integrated path differential absorption (IPDA) lidar is currently under development at NASA Langley Research Center (LaRC). This lidar targets both atmospheric carbon dioxide (CO2) and water vapor (H2O) column measurements, simultaneously. Advancements in the development of this IPDA lidar are presented in this paper. Updates on advanced two-micron triple-pulse high-energy laser transmitter will be given including packaging and lidar integration status. In addition, receiver development updates will also be presented. This includes a state-of-the-art detection system integrated at NASA Goddard Space Flight Center. This detection system is based on a newly developed HgCdTe (MCT) electron-initiated avalanche photodiode (e-APD) array. Future plan for IPDA lidar system for ground integration, testing and flight validation will be discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sumant, Anirudha
The integration of 2D materials such as molybdenum disulphide (MoS2) with diamond (3D) was achieved by forming an heterojunction between these two materials and its electrical performance was studied experimentally. The device charactertics did show good rectifying nature when p-type single crystal diamond was integrated with n-type MoS2. These results are very encouraging indicating possible applications in semiconductor electronics, however further studies are required for a detailed understanding of the transport phenomena at the MoS2/diamond interface.
Predicted performance benefits of an adaptive digital engine control system of an F-15 airplane
NASA Technical Reports Server (NTRS)
Burcham, F. W., Jr.; Myers, L. P.; Ray, R. J.
1985-01-01
The highly integrated digital electronic control (HIDEC) program will demonstrate and evaluate the improvements in performance and mission effectiveness that result from integrating engine-airframe control systems. Currently this is accomplished on the NASA Ames Research Center's F-15 airplane. The two control modes used to implement the systems are an integrated flightpath management mode and in integrated adaptive engine control system (ADECS) mode. The ADECS mode is a highly integrated mode in which the airplane flight conditions, the resulting inlet distortion, and the available engine stall margin are continually computed. The excess stall margin is traded for thrust. The predicted increase in engine performance due to the ADECS mode is presented in this report.
NASA Technical Reports Server (NTRS)
Uhran, M. L.; Youngblood, W. W.; Georgekutty, T.; Fiske, M. R.; Wear, W. O.
1986-01-01
Taking advantage of the microgravity environment of space NASA has initiated the preliminary design of a permanently manned space station that will support technological advances in process science and stimulate the development of new and improved materials having applications across the commercial spectrum. Previous studies have been performed to define from the researcher's perspective, the requirements for laboratory equipment to accommodate microgravity experiments on the space station. Functional requirements for the identified experimental apparatus and support equipment were determined. From these hardware requirements, several items were selected for concept designs and subsequent formulation of development plans. This report documents the concept designs and development plans for two items of experiment apparatus - the Combustion Tunnel and the Advanced Modular Furnace, and two items of support equipment the Laser Diagnostic System and the Integrated Electronics Laboratory. For each concept design, key technology developments were identified that are required to enable or enhance the development of the respective hardware.
NASA Astrophysics Data System (ADS)
Rusz, Ján; Lubk, Axel; Spiegelberg, Jakob; Tyutyunnikov, Dmitry
2017-12-01
The complex interplay of elastic and inelastic scattering amenable to different levels of approximation constitutes the major challenge for the computation and hence interpretation of TEM-based spectroscopical methods. The two major approaches to calculate inelastic scattering cross sections of fast electrons on crystals—Yoshioka-equations-based forward propagation and the reciprocal wave method—are founded in two conceptually differing schemes—a numerical forward integration of each inelastically scattered wave function, yielding the exit density matrix, and a computation of inelastic scattering matrix elements using elastically scattered initial and final states (double channeling). Here, we compare both approaches and show that the latter is computationally competitive to the former by exploiting analytical integration schemes over multiple excited states. Moreover, we show how to include full nonlocality of the inelastic scattering event, neglected in the forward propagation approaches, at no additional computing costs in the reciprocal wave method. Detailed simulations show in some cases significant errors due to the z -locality approximation and hence pitfalls in the interpretation of spectroscopical TEM results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfaraj, Nasir; Hussain, Aftab M.; Torres Sevilla, Galo A.
Flexibility can bring a new dimension to state-of-the-art electronics, such as rollable displays and integrated circuit systems being transformed into more powerful resources. Flexible electronics are typically hosted on polymeric substrates. Such substrates can be bent and rolled up, but cannot be independently fixed at the rigid perpendicular position necessary to realize rollable display-integrated gadgets and electronics. A reversibly bistable material can assume two stable states in a reversible way: flexibly rolled state and independently unbent state. Such materials are used in cycling and biking safety wristbands and a variety of ankle bracelets for orthopedic healthcare. They are often wrappedmore » around an object with high impulsive force loading. Here, we study the effects of cumulative impulsive force loading on thinned (25 μm) flexible silicon-based n-channel metal–oxide–semiconductor field-effect transistor devices housed on a reversibly bistable flexible platform. We found that the transistors have maintained their high performance level up to an accumulated 180 kN of impact force loading. The gate dielectric layers have maintained their reliability, which is evidenced by the low leakage current densities. Also, we observed low variation in the effective electron mobility values, which manifests that the device channels have maintained their carrier transport properties.« less
Multichannel, Active Low-Pass Filters
NASA Technical Reports Server (NTRS)
Lev, James J.
1989-01-01
Multichannel integrated circuits cascaded to obtain matched characteristics. Gain and phase characteristics of channels of multichannel, multistage, active, low-pass filter matched by making filter of cascaded multichannel integrated-circuit operational amplifiers. Concept takes advantage of inherent equality of electrical characteristics of nominally-identical circuit elements made on same integrated-circuit chip. Characteristics of channels vary identically with changes in temperature. If additional matched channels needed, chips containing more than two operational amplifiers apiece (e.g., commercial quad operational amplifliers) used. Concept applicable to variety of equipment requiring matched gain and phase in multiple channels - radar, test instruments, communication circuits, and equipment for electronic countermeasures.
Recent Progress of Self-Powered Sensing Systems for Wearable Electronics.
Lou, Zheng; Li, La; Wang, Lili; Shen, Guozhen
2017-12-01
Wearable/flexible electronic sensing systems are considered to be one of the key technologies in the next generation of smart personal electronics. To realize personal portable devices with mobile electronics application, i.e., wearable electronic sensors that can work sustainably and continuously without an external power supply are highly desired. The recent progress and advantages of wearable self-powered electronic sensing systems for mobile or personal attachable health monitoring applications are presented. An overview of various types of wearable electronic sensors, including flexible tactile sensors, wearable image sensor array, biological and chemical sensor, temperature sensors, and multifunctional integrated sensing systems is provided. Self-powered sensing systems with integrated energy units are then discussed, separated as energy harvesting self-powered sensing systems, energy storage integrated sensing systems, and all-in-on integrated sensing systems. Finally, the future perspectives of self-powered sensing systems for wearable electronics are discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Nanopillar arrays on semiconductor membranes as electron emission amplifiers.
Qin, Hua; Kim, Hyun-Seok; Blick, Robert H
2008-03-05
A new transmission-type electron multiplier was fabricated from silicon-on-insulator (SOI) material by integrating an array of one-dimensional (1D) silicon nanopillars onto a two-dimensional (2D) silicon membrane. Primary electrons are injected into the nanopillar-membrane (NPM) system from the flat surface of the membrane, while electron emission from the nanopillars is probed by an anode. The secondary electron yield (SEY) from the nanopillars in the current device is found to be about 1.8 times that of the plain silicon membrane. This gain in electron number is slightly enhanced by the electric field applied from the anode. Further optimization of the dimensions of the NPM and an application of field emission promise an even higher gain for detector applications and allow for probing of electronic/mechanical excitations in an NPM system stimulated by incident particles or radiation.
Riley, Erin M; Hattaway, Holly Z; Felse, P Arthur
2017-01-01
Electronic lab notebooks (ELNs) are better equipped than paper lab notebooks (PLNs) to handle present-day life science and engineering experiments that generate large data sets and require high levels of data integrity. But limited training and a lack of workforce with ELN knowledge have restricted the use of ELN in academic and industry research laboratories which still rely on cumbersome PLNs for recordkeeping. We used LabArchives, a cloud-based ELN in our bioprocess engineering lab course to train students in electronic record keeping, good documentation practices (GDPs), and data integrity. Implementation of ELN in the bioprocess engineering lab course, an analysis of user experiences, and our development actions to improve ELN training are presented here. ELN improved pedagogy and learning outcomes of the lab course through stream lined workflow, quick data recording and archiving, and enhanced data sharing and collaboration. It also enabled superior data integrity, simplified information exchange, and allowed real-time and remote monitoring of experiments. Several attributes related to positive user experiences of ELN improved between the two subsequent years in which ELN was offered. Student responses also indicate that ELN is better than PLN for compliance. We demonstrated that ELN can be successfully implemented in a lab course with significant benefits to pedagogy, GDP training, and data integrity. The methods and processes presented here for ELN implementation can be adapted to many types of laboratory experiments.
2014-01-01
Background Multiple tasking is an integral part of daily mobility. Patients with Parkinson’s disease have dual tasking difficulties due to their combined motor and cognitive deficits. Two contrasting physiotherapy interventions have been proposed to alleviate dual tasking difficulties: either to discourage simultaneous execution of dual tasks (consecutive training); or to practice their concurrent use (integrated training). It is currently unclear which of these training methods should be adopted to achieve safe and consolidated dual task performance in daily life. Therefore, the proposed randomized controlled trial will compare the effects of integrated versus consecutive training of dual tasking (tested by combining walking with cognitive exercises). Methods and design Hundred and twenty patients with Parkinson’s disease will be recruited to participate in this multi-centered, single blind, randomized controlled trial. Patients in Hoehn & Yahr stage II-III, with or without freezing of gait, and who report dual task difficulties will be included. All patients will undergo a six-week control period without intervention after which they will be randomized to integrated or consecutive task practice. Training will consist of standardized walking and cognitive exercises delivered at home four times a week during six weeks. Treatment is guided by a physiotherapist twice a week and consists of two sessions of self-practice using an MP3 player. Blinded testers will assess patients before and after the control period, after the intervention period and after a 12-week follow-up period. The primary outcome measure is dual task gait velocity, i.e. walking combined with a novel untrained cognitive task to evaluate the consolidation of learning. Secondary outcomes include several single and dual task gait and cognitive measures, functional outcomes and a quality of life scale. Falling will be recorded as a possible adverse event using a weekly phone call for the entire study period. Discussion This randomized study will evaluate the effectiveness and safety of integrated versus consecutive task training in patients with Parkinson’s disease. The study will also highlight whether dual task gait training leads to robust motor learning effects, and whether these can be retained and carried-over to untrained dual tasks and functional mobility. Trial registration Clinicaltrials.gov NCT01375413. PMID:24674594
Heyndrickx, Wouter; Salvador, Pedro; Bultinck, Patrick; Solà, Miquel; Matito, Eduard
2011-02-01
Several definitions of an atom in a molecule (AIM) in three-dimensional (3D) space, including both fuzzy and disjoint domains, are used to calculate electron sharing indices (ESI) and related electronic aromaticity measures, namely, I(ring) and multicenter indices (MCI), for a wide set of cyclic planar aromatic and nonaromatic molecules of different ring size. The results obtained using the recent iterative Hirshfeld scheme are compared with those derived from the classical Hirshfeld method and from Bader's quantum theory of atoms in molecules. For bonded atoms, all methods yield ESI values in very good agreement, especially for C-C interactions. In the case of nonbonded interactions, there are relevant deviations, particularly between fuzzy and QTAIM schemes. These discrepancies directly translate into significant differences in the values and the trends of the aromaticity indices. In particular, the chemically expected trends are more consistently found when using disjoint domains. Careful examination of the underlying effects reveals the different reasons why the aromaticity indices investigated give the expected results for binary divisions of 3D space. Copyright © 2010 Wiley Periodicals, Inc.
Volatility and Growth in Populations of Rural Associations
ERIC Educational Resources Information Center
Wollebaek, Dag
2010-01-01
This article uses unique community-level data aggregated from censuses of associations to analyze growth and volatility in rural populations of grassroots associations. A qualitative comparative analysis (QCA) shows that the two main paths to growth were (1) centralization in polycephalous (multicentered) municipalities and (2) population growth…
Mems: Platform for Large-Scale Integrated Vacuum Electronic Circuits
2017-03-20
SECURITY CLASSIFICATION OF: The objective of the LIVEC advanced study project was to develop a platform for large-scale integrated vacuum electronic ...Distribution Unlimited UU UU UU UU 20-03-2017 1-Jul-2014 30-Jun-2015 Final Report: MEMS Platform for Large-Scale Integrated Vacuum Electronic ... Electronic Circuits (LIVEC) Contract No: W911NF-14-C-0093 COR Dr. James Harvey U.S. ARO RTP, NC 27709-2211 Phone: 702-696-2533 e-mail
Review Of E-Beam Electrical Test Techniques
NASA Astrophysics Data System (ADS)
Hohn, Fritz J.
1987-09-01
Electron beams as a viable technique for contactless testing of electrical functions and electrical integrity of different active devices in VLSI-chips has been demonstrated over the past years. This method of testing electronic networks, most widely used in the laboratory environment, is based on an electron probe which is deflected from point to point in the network. A current of secondary electrons emitted in response to the impingement of the electron probe is converted to a signal indicating the presence of a voltage or varying potential at the different points. Voltage contrast, electron beam induced current, dual potential approach, stroboscopic techniques and other methods have been developed and are used to detect different functional failures in devices. Besides the VLSI application, the contactless testing of three dimensional conductor networks of a 10cm x 10cm x .8cm multilayer ceramic module poses a different and new application for the electron beam test technique. A dual potential electron beam test system allows to generate electron beam induced voltage contrast. The same system at a different potential is used to detect this voltage contrast over the large area without moving the substrate and thus test for the electrical integrity of the networks. Less attention in most of the applications has been paid to the electron optical environment, mostly SEM's were upgraded or converted to do the job of a "voltage contrast" machine. This by no means will satisfy all requirements and more thoughts have to be given to aspects such as: low voltage electron guns: thermal emitter, Schottky emitter, field emitter, low voltage electron optics, two lens systems, different means of detection, signal processing - storage and others. This paper will review available E-beam test techniques, specific applications and some critical components.
Wu, Albert W.; Kharrazi, Hadi; Boulware, L. Ebony; Snyder, Claire F.
2013-01-01
Objective This paper presents the current state of patient-reported outcome measures, and explains new opportunities for leveraging the recent adoption of electronic health records to expand the application of patient-reported outcomes in both clinical care and comparative effectiveness research. Study Design and Setting Historic developments of patient-reported outcome, electronic health record, and comparative effectiveness research are analyzed in two dimensions: patient-centeredness and digitization. We pose the question: “What needs to be standardized around the collection of patient-reported outcomes in electronic health records for comparative effectiveness research?” Results We identified three converging trends: the progression of patient-reported outcomes toward greater patient centeredness and electronic adaptation; the evolution of electronic health records into personalized and fully digitized solutions; the shift toward patient-oriented comparative effectiveness research. Related to this convergence, we propose an architecture for patient-reported outcome standardization that could serve as a first step toward a more comprehensive integration of patient-reported outcomes with electronic health record for both practice and research. Conclusion The science of patient-reported outcome measurement has matured sufficiently to be integrated routinely into electronic health records and other e-health solutions to collect data on an ongoing basis for clinical care and comparative effectiveness research. Further efforts and ideally coordinated efforts from various stakeholders are needed to refine the details of the proposed framework for standardization. PMID:23849145
Javadi, Mohammad; Alizadeh, Saba; Khosravi, Yusef; Abdi, Yaser
2016-11-04
The integration of fast electron transport and large effective surface area is critical to attaining higher gains in the nanostructured photovoltaic devices. Here, we report facilitated electron transport in the quasi-two-dimensional (Q2D) porous TiO 2 . Liquid electrolyte dye-sensitized solar cells were prepared by utilizing photoanodes based on the Q2D porous substructures. Due to electron confinement in a microscale porous medium, directional diffusion toward collecting electrode is induced into the electron transport. Our measurements based on the photocurrent and photovoltage time-of-flight transients show that at higher Fermi levels, the electron diffusion coefficient in the Q2D porous TiO 2 is about one order of magnitude higher when compared with the conventional layer of porous TiO 2 . The results show that microstructuring of the porous TiO 2 leads to an approximately threefold improvement in the electron diffusion length. Such a modification may considerably affects the electrical functionality of moderate or low performance dye-sensitized solar cells for which the internal gain or collection efficiency is typically low. © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Flexible and weaveable capacitor wire based on a carbon nanocomposite fiber.
Ren, Jing; Bai, Wenyu; Guan, Guozhen; Zhang, Ye; Peng, Huisheng
2013-11-06
A flexible and weaveable electric double-layer capacitor wire is developed by twisting two aligned carbon nanotube/ordered mesoporous carbon composite fibers with remarkable mechanical and electronic properties as electrodes. This capacitor wire exhibits high specific capacitance and long life stability. Compared with the conventional planar structure, the capacitor wire is also lightweight and can be integrated into various textile structures that are particularly promising for portable and wearable electronic devices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hernandez, Penni; Podchiyska, Tanya; Weber, Susan; Ferris, Todd; Lowe, Henry
2009-11-14
The Stanford Translational Research Integrated Database Environment (STRIDE) clinical data warehouse integrates medication information from two Stanford hospitals that use different drug representation systems. To merge this pharmacy data into a single, standards-based model supporting research we developed an algorithm to map HL7 pharmacy orders to RxNorm concepts. A formal evaluation of this algorithm on 1.5 million pharmacy orders showed that the system could accurately assign pharmacy orders in over 96% of cases. This paper describes the algorithm and discusses some of the causes of failures in mapping to RxNorm.
Bespamyatnov, I O; Rowan, W L; Liao, K T; Granetz, R S
2010-10-01
A novel integrated charge exchange recombination spectroscopy (CXRS)/beam emission spectroscopy (BES) system is proposed for C-Mod, in which both measurements are taken from a shared viewing geometry. The supplementary BES system serves to quantify local beam densities and supplants the common calculation of beam attenuation. The new system employs two optical viewing arrays, 20 poloidal and 22 toroidal channels. A dichroic filter splits the light between two spectrometers operating at different wavelengths for impurity ion and beam neutrals emission. In this arrangement, the impurity density is inferred from the electron density, measured BES and CXRS spectral radiances, and atomic emission rates.
A study on airborne integrated display system and human information processing
NASA Technical Reports Server (NTRS)
Mizumoto, K.; Iwamoto, H.; Shimizu, S.; Kuroda, I.
1983-01-01
The cognitive behavior of pilots was examined in an experiment involving mock ups of an eight display electronic attitude direction indicator for an airborne integrated display. Displays were presented in digital, analog digital, and analog format to experienced pilots. Two tests were run, one involving the speed of memorization in a single exposure and the other comprising two five second exposures spaced 30 sec apart. Errors increased with the speed of memorization. Generally, the analog information was assimilated faster than the digital data, with regard to the response speed. Information processing was quantified as 25 bits for the first five second exposure and 15 bits during the second.
Path-integral isomorphic Hamiltonian for including nuclear quantum effects in non-adiabatic dynamics
NASA Astrophysics Data System (ADS)
Tao, Xuecheng; Shushkov, Philip; Miller, Thomas F.
2018-03-01
We describe a path-integral approach for including nuclear quantum effects in non-adiabatic chemical dynamics simulations. For a general physical system with multiple electronic energy levels, a corresponding isomorphic Hamiltonian is introduced such that Boltzmann sampling of the isomorphic Hamiltonian with classical nuclear degrees of freedom yields the exact quantum Boltzmann distribution for the original physical system. In the limit of a single electronic energy level, the isomorphic Hamiltonian reduces to the familiar cases of either ring polymer molecular dynamics (RPMD) or centroid molecular dynamics Hamiltonians, depending on the implementation. An advantage of the isomorphic Hamiltonian is that it can easily be combined with existing mixed quantum-classical dynamics methods, such as surface hopping or Ehrenfest dynamics, to enable the simulation of electronically non-adiabatic processes with nuclear quantum effects. We present numerical applications of the isomorphic Hamiltonian to model two- and three-level systems, with encouraging results that include improvement upon a previously reported combination of RPMD with surface hopping in the deep-tunneling regime.
Density-functional theory simulation of large quantum dots
NASA Astrophysics Data System (ADS)
Jiang, Hong; Baranger, Harold U.; Yang, Weitao
2003-10-01
Kohn-Sham spin-density functional theory provides an efficient and accurate model to study electron-electron interaction effects in quantum dots, but its application to large systems is a challenge. Here an efficient method for the simulation of quantum dots using density-function theory is developed; it includes the particle-in-the-box representation of the Kohn-Sham orbitals, an efficient conjugate-gradient method to directly minimize the total energy, a Fourier convolution approach for the calculation of the Hartree potential, and a simplified multigrid technique to accelerate the convergence. We test the methodology in a two-dimensional model system and show that numerical studies of large quantum dots with several hundred electrons become computationally affordable. In the noninteracting limit, the classical dynamics of the system we study can be continuously varied from integrable to fully chaotic. The qualitative difference in the noninteracting classical dynamics has an effect on the quantum properties of the interacting system: integrable classical dynamics leads to higher-spin states and a broader distribution of spacing between Coulomb blockade peaks.
Eigenstates and dynamics of Hooke's atom: Exact results and path integral simulations
NASA Astrophysics Data System (ADS)
Gholizadehkalkhoran, Hossein; Ruokosenmäki, Ilkka; Rantala, Tapio T.
2018-05-01
The system of two interacting electrons in one-dimensional harmonic potential or Hooke's atom is considered, again. On one hand, it appears as a model for quantum dots in a strong confinement regime, and on the other hand, it provides us with a hard test bench for new methods with the "space splitting" arising from the one-dimensional Coulomb potential. Here, we complete the numerous previous studies of the ground state of Hooke's atom by including the excited states and dynamics, not considered earlier. With the perturbation theory, we reach essentially exact eigenstate energies and wave functions for the strong confinement regime as novel results. We also consider external perturbation induced quantum dynamics in a simple separable case. Finally, we test our novel numerical approach based on real-time path integrals (RTPIs) in reproducing the above. The RTPI turns out to be a straightforward approach with exact account of electronic correlations for solving the eigenstates and dynamics without the conventional restrictions of electronic structure methods.
Chee, Augustus K. W.
2016-01-01
Two-dimensional dopant profiling using the secondary electron (SE) signal in the scanning electron microscope (SEM) is a technique gaining impulse for its ability to enable rapid and contactless low-cost diagnostics for integrated device manufacturing. The basis is doping contrast from electrical p-n junctions, which can be influenced by wet-chemical processing methods typically adopted in ULSI technology. This paper describes the results of doping contrast studies by energy-filtering in the SEM from silicon p-n junction specimens that were etched in ammonium fluoride solution. Experimental SE micro-spectroscopy and numerical simulations indicate that Fermi level pinning occurred on the surface of the treated-specimen, and that the doping contrast can be explained in terms of the ionisation energy integral for SEs, which is a function of the dopant concentration, and surface band-bending effects that prevail in the mechanism for doping contrast as patch fields from the specimen are suppressed. PMID:27576347
Total-dose radiation effects data for semiconductor devices. 1985 Supplement. Volume 2, part B
NASA Technical Reports Server (NTRS)
Martin, K. E.; Gauthier, M. K.; Coss, J. R.; Dantas, A. R. V.; Price, W. E.
1986-01-01
Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 (Parts A and B) provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done steady-state 2.5-MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose. All data were generated in support of NASA space programs by the JPL Radiation Effects and Testing Group (514).
Electronics Thermal Management Using Advanced Hybrid Two-Phase Loop Technology
2007-07-08
high heat flux cooling systems [Kawaji and Chung, 2003; Estes and Mudawar , 1995]. The successful integration of mechanical pumps into the heat...1st International Conference on Microchannels and Minichannels, Rochester, New York, April 24~25, 2003. Estes, K. and Mudawar , I., “Comparison of
Brailo, Vlaho; Firriolo, Francis John; Tanaka, Takako Imai; Varoni, Elena; Sykes, Rosemary; McCullough, Michael; Hua, Hong; Sklavounou, Alexandra; Jensen, Siri Beier; Lockhart, Peter B; Mattsson, Ulf; Jontell, Mats
2015-08-01
To assess the current scope and status of Oral Medicine-specific software (OMSS) utilized to support clinical care, research, and education in Oral Medicine and to propose a strategy for broader implementation of OMSS within the global Oral Medicine community. An invitation letter explaining the objectives was sent to the global Oral Medicine community. Respondents were interviewed to obtain information about different aspects of OMSS functionality. Ten OMSS tools were identified. Four were being used for clinical care, one was being used for research, two were being used for education, and three were multipurpose. Clinical software was being utilized as databases developed to integrate of different type of clinical information. Research software was designed to facilitate multicenter research. Educational software represented interactive, case-orientated technology designed for clinical training in Oral Medicine. Easy access to patient data was the most commonly reported advantage. Difficulty of use and poor integration with other software was the most commonly reported disadvantage. The OMSS presented in this paper demonstrate how information technology (IT) can have an impact on the quality of patient care, research, and education in the field of Oral Medicine. A strategy for broader implementation of OMSS is proposed. Copyright © 2015 Elsevier Inc. All rights reserved.
Integrating an Academic Electronic Health Record: Challenges and Success Strategies.
Herbert, Valerie M; Connors, Helen
2016-08-01
Technology is increasing the complexity in the role of today's nurse. Healthcare organizations are integrating more health information technologies and relying on the electronic health record for data collection, communication, and decision making. Nursing faculty need to prepare graduates for this environment and incorporate an academic electronic health record into a nursing curriculum to meet student-program outcomes. Although the need exists for student preparation, some nursing programs are struggling with implementation, whereas others have been successful. To better understand these complexities, this project was intended to identify current challenges and success strategies of effective academic electronic health record integration into nursing curricula. Using Rogers' 1962 Diffusion of Innovation theory as a framework for technology adoption, a descriptive survey design was used to gain insights from deans and program directors of nursing schools involved with the national Health Informatics & Technology Scholars faculty development program or Cerner's Academic Education Solution Consortium, working to integrate an academic electronic health record in their respective nursing schools. The participants' experiences highlighted approaches used by these schools to integrate these technologies. Data from this project provide nursing education with effective strategies and potential challenges that should be addressed for successful academic electronic health record integration.
Two-photon double ionization of helium in the region of photon energies 42-50eV
NASA Astrophysics Data System (ADS)
Ivanov, I. A.; Kheifets, A. S.
2007-03-01
We report the total integrated cross section (TICS) of two-photon double ionization of helium in the photon energy range from 42to50eV . Our computational procedure relies on a numerical solution of the time-dependent Schrödinger equation on a square-integrable basis and subsequent projection of this solution on a set of final field-free states describing correlation in the two-electron continuum. Our results suggest that the TICS grows monotonically as a function of photon energy in the region of 42-50eV , possibly reaching a maximum in the vicinity of 50eV . We also present fully resolved triple-differential cross sections for selected photon energies.
Morace, G.; Amato, G.; Bistoni, F.; Fadda, G.; Marone, P.; Montagna, M. T.; Oliveri, S.; Polonelli, L.; Rigoli, R.; Mancuso, I.; La Face, S.; Masucci, L.; Romano, L.; Napoli, C.; Tatò, D.; Buscema, M. G.; Belli, C. M. C.; Piccirillo, M. M.; Conti, S.; Covan, S.; Fanti, F.; Cavanna, C.; D'Alò, F.; Pitzurra, L.
2002-01-01
Fluconazole susceptibility among 800 clinical Candida isolates (60% C. albicans) and two control strains (C. krusei ATCC 6258 and C. parapsilosis ATCC 22019) was tested with the NCCLS M27-A method (gold standard) and six commercial products (Candifast, disk, Etest, Fungitest, Integral System Yeasts, and Sensititre YeastOne). Results were classified as susceptible, susceptible-dose dependent, or resistant using M27-A breakpoints or, for Fungitest, Integral System Yeasts, and Candifast, as susceptible, intermediate, or resistant, according to the manufacturers' instructions. Concordance with NCCLS M27-A results was analyzed with the χ2 test. Intra- and interlaboratory reproducibility was also evaluated. NCCLS M27-A (90.1%), Etest (93.1%), Sensititre YeastOne (93.1%), disk (96.7%), Fungitest (92.6%), Integral System Yeasts (40.6%), and Candifast (6.0%) classified the indicated percentages of C. albicans isolates as susceptible. Among non-C. albicans strains, the percentages of susceptible isolates were as follows: NCCLS M27-A, 74.0%; Etest, 83.8%; Sensititre YeastOne, 64.1%; disk, 60.6%; Fungitest, 76.6%; Integral System Yeasts, 28.3%; and Candifast, 27.4%. All methods except Candifast and Integral System Yeasts showed good agreement with NCCLS M27-A results for both C albicans and non-C. albicans isolates. Intralaboratory reproducibility was excellent for NCCLS M27-A, Etest, Sensititre YeastOne, disk, and Fungitest (88 to 91%). Similar results emerged from the interlaboratory reproducibility evaluation. Our findings indicate that some commercial methods can be useful for fluconazole susceptibility testing of clinical Candida isolates. Those characterized by a lack of medium standardization and/or objective interpretative criteria should be avoided. Particular caution is necessary when testing is being done for clinical and epidemiological purposes. PMID:12149358
Multipurpose silicon photonics signal processor core.
Pérez, Daniel; Gasulla, Ivana; Crudgington, Lee; Thomson, David J; Khokhar, Ali Z; Li, Ke; Cao, Wei; Mashanovich, Goran Z; Capmany, José
2017-09-21
Integrated photonics changes the scaling laws of information and communication systems offering architectural choices that combine photonics with electronics to optimize performance, power, footprint, and cost. Application-specific photonic integrated circuits, where particular circuits/chips are designed to optimally perform particular functionalities, require a considerable number of design and fabrication iterations leading to long development times. A different approach inspired by electronic Field Programmable Gate Arrays is the programmable photonic processor, where a common hardware implemented by a two-dimensional photonic waveguide mesh realizes different functionalities through programming. Here, we report the demonstration of such reconfigurable waveguide mesh in silicon. We demonstrate over 20 different functionalities with a simple seven hexagonal cell structure, which can be applied to different fields including communications, chemical and biomedical sensing, signal processing, multiprocessor networks, and quantum information systems. Our work is an important step toward this paradigm.Integrated optical circuits today are typically designed for a few special functionalities and require complex design and development procedures. Here, the authors demonstrate a reconfigurable but simple silicon waveguide mesh with different functionalities.
Visualizing light with electrons
NASA Astrophysics Data System (ADS)
Fitzgerald, J. P. S.; Word, R. C.; Koenenkamp, R.
2014-03-01
In multiphoton photoemission electron microscopy (nP-PEEM) electrons are emitted from surfaces at a rate proportional to the surface electromagnetic field amplitude. We use 2P-PEEM to give nanometer scale visualizations of light of diffracted and waveguide fields around various microstructures. We use Fourier analysis to determine the phase and amplitude of surface fields in relation to incident light from the interference patterns. To provide quick and intuitive simulations of surface fields, we employ two dimensional Fresnel-Kirchhoff integration, a technique based on freely propagating waves and Huygens' principle. We find generally good agreement between simulations and experiment. Additionally diffracted wave simulations exhibit greater phase accuracy, indicating that these waves are well represented by a two dimensional approximation. The authors gratefully acknowledge funding of this research by the US-DOE Basic Science Office under Contract DE-FG02-10ER46406.
NASA Astrophysics Data System (ADS)
Somogyi, Gábor
2013-04-01
We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of fully differential rates for electron-positron annihilation into two and three jets at NNLO accuracy becomes feasible.
Gorelick, Marc H; Knight, Stacey; Alessandrini, Evaline A; Stanley, Rachel M; Chamberlain, James M; Kuppermann, Nathan; Alpern, Elizabeth R
2007-07-01
Diagnosis information from existing data sources is used commonly for epidemiologic, administrative, and research purposes. The quality of such data for emergency department (ED) visits is unknown. To determine the agreement on final diagnoses between two sources, electronic administrative sources and manually abstracted medical records, for pediatric ED visits, in a multicenter network. This was a cross sectional study at 19 EDs nationwide. The authors obtained data from two sources at each ED during a three-month period in 2003: administrative sources for all visits and abstracted records for randomly selected visits during ten days over the study period. Records were matched using unique identifiers and probabilistic linkage. The authors recorded up to three diagnoses from each abstracted medical record and up to ten for the administrative data source. Diagnoses were grouped into 104 groups using a modification of the Clinical Classification System. A total of 8,860 abstracted records had at least one valid diagnosis code (with a total of 12,895 diagnoses) and were successfully matched to records in the administrative source. Overall, 67% (95% confidence interval = 66% to 68%) of diagnoses from the administrative and abstracted sources were within the same diagnosis group. Agreement varied by site, ranging from 54% to 77%. Agreement varied substantially by diagnosis group; there was no difference by method of linkage. Clustering clinically similar diagnosis groups improved agreement between administrative and abstracted data sources. ED diagnoses retrieved from electronic administrative sources and manual chart review frequently disagree, even if similar diagnosis codes are grouped. Agreement varies by institution and by diagnosis. Further work is needed to improve the accuracy of diagnosis coding; development of a grouping system specific to pediatric emergency care may be beneficial.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vay, J.-L.; Furman, M.A.; Azevedo, A.W.
2004-04-19
We have integrated the electron-cloud code POSINST [1] with WARP [2]--a 3-D parallel Particle-In-Cell accelerator code developed for Heavy Ion Inertial Fusion--so that the two can interoperate. Both codes are run in the same process, communicate through a Python interpreter (already used in WARP), and share certain key arrays (so far, particle positions and velocities). Currently, POSINST provides primary and secondary sources of electrons, beam bunch kicks, a particle mover, and diagnostics. WARP provides the field solvers and diagnostics. Secondary emission routines are provided by the Tech-X package CMEE.
Léger, Julie; Tandé, Didier; Plouzeau, Chloé; Valentin, Anne Sophie; Jolivet-Gougeon, Anne; Lemarié, Carole; Kempf, Marie; Héry-Arnaud, Geneviève; Bret, Laurent; Juvin, Marie Emmanuelle; Giraudeau, Bruno; Burucoa, Christophe
2015-01-01
Although numerous perioperative samples and culture media are required to diagnose prosthetic joint infection (PJI), their exact number and types have not yet been definitely determined with a high level of proof. We conducted a prospective multicenter study to determine the minimal number of samples and culture media required for accurate diagnosis of PJI. Over a 2-year period, consecutive patients with clinical signs suggesting PJI were included, with five perioperative samples per patient. The bacteriological and PJI diagnosis criteria were assessed using a random selection of two, three, or four samples and compared with those obtained using the recommended five samples (references guidelines). The results obtained with two or three culture media were then compared with those obtained with five culture media for both criteria. The times-to-positivity of the different culture media were calculated. PJI was confirmed in 215/264 suspected cases, with a bacteriological criterion in 192 (89%). The PJI was monomicrobial (85%) or polymicrobial (15%). Percentages of agreement of 98.1% and 99.7%, respectively, for the bacteriological criterion and confirmed PJI diagnosis were obtained when four perioperative samples were considered. The highest percentages of agreement were obtained with the association of three culture media, a blood culture bottle, a chocolate agar plate, and Schaedler broth, incubated for 5, 7, and 14 days, respectively. This new procedure leads to significant cost saving. Our prospective multicenter study showed that four samples seeded on three culture media are sufficient for diagnosing PJI. PMID:26637380
Bémer, Pascale; Léger, Julie; Tandé, Didier; Plouzeau, Chloé; Valentin, Anne Sophie; Jolivet-Gougeon, Anne; Lemarié, Carole; Kempf, Marie; Héry-Arnaud, Geneviève; Bret, Laurent; Juvin, Marie Emmanuelle; Giraudeau, Bruno; Corvec, Stéphane; Burucoa, Christophe
2016-02-01
Although numerous perioperative samples and culture media are required to diagnose prosthetic joint infection (PJI), their exact number and types have not yet been definitely determined with a high level of proof. We conducted a prospective multicenter study to determine the minimal number of samples and culture media required for accurate diagnosis of PJI. Over a 2-year period, consecutive patients with clinical signs suggesting PJI were included, with five perioperative samples per patient. The bacteriological and PJI diagnosis criteria were assessed using a random selection of two, three, or four samples and compared with those obtained using the recommended five samples (references guidelines). The results obtained with two or three culture media were then compared with those obtained with five culture media for both criteria. The times-to-positivity of the different culture media were calculated. PJI was confirmed in 215/264 suspected cases, with a bacteriological criterion in 192 (89%). The PJI was monomicrobial (85%) or polymicrobial (15%). Percentages of agreement of 98.1% and 99.7%, respectively, for the bacteriological criterion and confirmed PJI diagnosis were obtained when four perioperative samples were considered. The highest percentages of agreement were obtained with the association of three culture media, a blood culture bottle, a chocolate agar plate, and Schaedler broth, incubated for 5, 7, and 14 days, respectively. This new procedure leads to significant cost saving. Our prospective multicenter study showed that four samples seeded on three culture media are sufficient for diagnosing PJI. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
An, Hyeong Su; Moon, Won-Jin; Ryu, Jae-Kyun; Park, Ju Yeon; Yun, Won Sung; Choi, Jin Woo; Jahng, Geon-Ho; Park, Jang-Yeon
2017-12-01
This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P=0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC=0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC=0.961), while the Philips (ICC=0.671) and Siemens (ICC=0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker. Copyright © 2017 Elsevier Inc. All rights reserved.
Merrer, Jacques; Girou, Emmanuelle; Lortat-Jacob, Alain; Montravers, Philippe; Lucet, Jean-Christophe
2007-10-01
Femoral neck fracture is the most frequent orthopedic emergency among elderly persons. Despite a high prevalence of methicillin-resistant Staphylococcus aureus (MRSA) carriage in this population, no multicenter study of antibiotic prophylaxis practices and the rate and microbiological characteristics of surgical site infection (SSI) has been performed in France. Retrospective, multicenter cohort study. Twenty-two university and community hospitals in France. Each center provided data on 25 consecutive patients who underwent surgery for femoral neck fracture during the first quarter of 2005. Demographic, clinical, and follow-up characteristics were recorded, and most patients had a follow-up office visit or were involved in a telephone survey 1 year after surgery. These 22 centers provided data on 541 patients, 396 (73%) of whom were followed up 1 year after surgery. Of 504 (93%) patients for whom antibiotic prophylaxis was recorded, 433 (86%) received a cephalosporin. Twenty-two patients had an SSI, for a rate of 5.6% (95% confidence interval, 3.7-8.0). SSI was reported for 15 (6.9%) of patients who had a prosthesis placed and for 7 (3.9%) who underwent osteosynthesis (P=.27). SSI was diagnosed a median of 30 days after surgery (interquartile range, 21-41 days); 7 (32%) of these SSIs were superficial infections, and 15 (68%) were deep or organ-space infections. MRSA caused 7 SSIs (32%), Pseudomonas aeruginosa caused 5 (23%), other staphylococci caused 4 (18%), and other bacteria caused 2 (9%); the etiologic pathogen was unknown in 4 cases (18%). Reoperation was performed for 14 patients with deep or organ-space SSI, including 6 of 7 patients with MRSA SSI. The mortality rate 1 year after surgery was 20% overall but 50% among patients with SSI. In univariate analysis, only the National Nosocomial Infections Surveillance System risk index score was significantly associated with SSI (P=.006). SSI after surgery for femoral neck fracture is severe, and MRSA is the most frequently encountered etiologic pathogen. A large, multicenter prospective trial is necessary to determine whether the use of antibiotic prophylaxis effective against MRSA would decrease the SSI rate in this population.
2014-01-01
Background Blunt head trauma is a common cause of death and disability in children worldwide. Cranial computed tomography (CT), the reference standard for the diagnosis of traumatic brain injury (TBI), exposes children to ionizing radiation which has been linked to the development of brain tumors, leukemia, and other cancers. We describe the methods used to develop and test the effectiveness of a decision aid to facilitate shared decision-making with parents regarding whether to obtain a head CT scan or to further observe their child at home. Methods/Design This is a protocol for a multicenter clinician-level parallel randomized trial to compare an intervention group receiving a decision aid, ‘Head CT Choice’, to a control group receiving usual care. The trial will be conducted at five diverse emergency departments (EDs) in Minnesota and California. Clinicians will be randomized to decision aid or usual care. Parents visiting the ED with children who are less than 18-years-old, have experienced blunt head trauma within 24 hours, and have one or two risk factors for clinically-important TBI (ciTBI) from the Pediatric Emergency Care Applied Research Network head injury clinical prediction rules will be eligible for enrollment. We will measure the effect of Head CT Choice on: (1) parent knowledge regarding their child’s risk of ciTBI, the available diagnostic options, and the risks of radiation exposure associated with a cranial CT scan (primary outcome); (2) parent engagement in the decision-making process; (3) the degree of conflict parents experience related to feeling uninformed; (4) patient and clinician satisfaction with the decision made; (5) the rate of ciTBI at seven days; (6) the proportion of patients in whom a cranial CT scan is obtained; and (7) seven-day healthcare utilization. To capture these outcomes, we will administer parent and clinician surveys immediately after each clinical encounter, obtain video recordings of parent-clinician discussions, administer parent healthcare utilization diaries, analyze hospital billing records, review the electronic medical record, and conduct telephone follow-up. Discussion This multicenter trial will robustly assess the effectiveness of a decision aid on patient-centered outcomes, safety, and healthcare utilization in parents of children with minor head trauma in five diverse EDs. Trial registration ClinicalTrials.gov registration number: NCT02063087. Registration date February 13, 2014. PMID:24965659
Problems related to the integration of fault tolerant aircraft electronic systems
NASA Technical Reports Server (NTRS)
Bannister, J. A.; Adlakha, V.; Triyedi, K.; Alspaugh, T. A., Jr.
1982-01-01
Problems related to the design of the hardware for an integrated aircraft electronic system are considered. Taxonomies of concurrent systems are reviewed and a new taxonomy is proposed. An informal methodology intended to identify feasible regions of the taxonomic design space is described. Specific tools are recommended for use in the methodology. Based on the methodology, a preliminary strawman integrated fault tolerant aircraft electronic system is proposed. Next, problems related to the programming and control of inegrated aircraft electronic systems are discussed. Issues of system resource management, including the scheduling and allocation of real time periodic tasks in a multiprocessor environment, are treated in detail. The role of software design in integrated fault tolerant aircraft electronic systems is discussed. Conclusions and recommendations for further work are included.
Heterogeneous Monolithic Integration of Single-Crystal Organic Materials.
Park, Kyung Sun; Baek, Jangmi; Park, Yoonkyung; Lee, Lynn; Hyon, Jinho; Koo Lee, Yong-Eun; Shrestha, Nabeen K; Kang, Youngjong; Sung, Myung Mo
2017-02-01
Manufacturing high-performance organic electronic circuits requires the effective heterogeneous integration of different nanoscale organic materials with uniform morphology and high crystallinity in a desired arrangement. In particular, the development of high-performance organic electronic and optoelectronic devices relies on high-quality single crystals that show optimal intrinsic charge-transport properties and electrical performance. Moreover, the heterogeneous integration of organic materials on a single substrate in a monolithic way is highly demanded for the production of fundamental organic electronic components as well as complex integrated circuits. Many of the various methods that have been designed to pattern multiple heterogeneous organic materials on a substrate and the heterogeneous integration of organic single crystals with their crystal growth are described here. Critical issues that have been encountered in the development of high-performance organic integrated electronics are also addressed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wireless hydrotherapy smart suit for monitoring handicapped people
NASA Astrophysics Data System (ADS)
Correia, Jose H.; Mendes, Paulo M.
2005-02-01
This paper presents a smart suit, water impermeable, containing sensors and electronics for monitoring handicapped people at hydrotherapy sessions in swimming-pools. For integration into textiles, electronic components should be designed in a functional, robust and inexpensive way. Therefore, small-size electronics microsystems are a promising approach. The smart suit allows the monitoring of individual biometric data, such as heart rate, temperature and movement of the body. Two solutions for transmitting the data wirelessly are presented: through a low-voltage (3.0 V), low-power, CMOS RF IC (1.6 mm x 1.5 mm size dimensions) operating at 433 MHz, with ASK modulation and a patch antenna built on lossy substrates compatible with integrated circuits fabrication. Two different substrates were used for antenna implementation: high-resistivity silicon (HRS) and Corning Pyrex #7740 glass. The antenna prototypes were built to operate close to the 5 GHz ISM band. They operate at a center frequency of 5.705 GHz (HRS) and 5.995 GHz (Pyrex). The studied parameters were: substrate thickness, substrate losses, oxide thickness, metal conductivity and thickness. The antenna on HRS uses an area of 8 mm2, providing a 90 MHz bandwidth and ~0.3 dBi of gain. On a glass substrate, the antenna uses 12 mm2, provides 100 MHz bandwidth and ~3 dBi of gain.
Integration of Histology Lectures and Practical Teaching in China
ERIC Educational Resources Information Center
Lu, Xiaoye; Cheng, Xin; Li, Ke; Lee, Kenneth Ka Ho; Yang, Xuesong
2016-01-01
Objectives: Human histology is a discipline concerning the study of microscopic structures of human tissues and organs--with the aid of light or electron microscopes. Traditional teaching of histology is composed of two separated components, theory and practice. The main disadvantage with traditional histology teaching is the detachment of theory…
Relativistic radiationless transitions in atoms
NASA Technical Reports Server (NTRS)
Huang, K.-N.
1978-01-01
The perturbing interaction appropriate for the Dirac-Fock formalism is used to formulate relativistic radiationless transitions. The transition rate between two jj-coupled many-electron configurations is expressed as a linear combination of radial integrals, suitable for numerical computation. The correlation and relaxation effects and the generalisation of the present work are discussed briefly.
Koga, Tomohiro; Okada, Akitomo; Fukuda, Takaaki; Hidaka, Toshihiko; Ishii, Tomonori; Ueki, Yukitaka; Kodera, Takao; Nakashima, Munetoshi; Takahashi, Yuichi; Honda, Seiyo; Horai, Yoshiro; Watanabe, Ryu; Okuno, Hiroshi; Aramaki, Toshiyuki; Izumiyama, Tomomasa; Takai, Osamu; Miyashita, Taiichiro; Sato, Shuntaro; Kawashiri, Shin-Ya; Iwamoto, Naoki; Ichinose, Kunihiro; Tamai, Mami; Origuchi, Tomoki; Nakamura, Hideki; Aoyagi, Kiyoshi; Eguchi, Katsumi; Kawakami, Atsushi
2016-04-01
To determine prognostic factors of clinically relevant radiographic progression (CRRP) in patients with rheumatoid arthritis (RA) in clinical practice.We performed a multicenter prospective study in Japan of biological disease-modifying antirheumatic drug (bDMARD)-naive RA patients with moderate to high disease activity treated with conventional synthetic DMARDs (csDMARDs) at study entry. We longitudinally observed 408 patients for 1 year and assessed disease activity every 3 months. CRRP was defined as yearly progression of modified total Sharp score (mTSS) > 3.0 U. We also divided the cohort into 2 groups based on disease duration (<3 vs ≥3 years) and performed a subgroup analysis.CRRP was found in 10.3% of the patients. A multiple logistic regression analysis revealed that the independent variables to predict the development of CRRP were: CRP at baseline (0.30 mg/dL increase, 95% confidence interval [CI] 1.01-1.11), time-integrated Disease Activity Score in 28 joints-erythrocyte sedimentation rate (DAS28-ESR) during the 1 year postbaseline (12.4-unit increase, 95%CI 1.17-2.59), RA typical erosion at baseline (95%CI 1.56-21.1), and the introduction of bDMARDs (95%CI 0.06-0.38). The subgroup analysis revealed that time-integrated DAS28-ESR is not a predictor whereas the introduction of bDMARDs is a significant protective factor for CRRP in RA patients with disease duration <3 years.We identified factors that could be used to predict the development of CRRP in RA patients treated with DMARDs. These variables appear to be different based on the RA patients' disease durations.
Electron-proton spectrometer design summary
NASA Technical Reports Server (NTRS)
1972-01-01
The electron-proton spectrometer (EPS) will be placed aboard the Skylab in order to provide data from which electron and proton radiation dose can be determined. The EPS has five sensors, each consisting of a shielded silicon detector. These provide four integral electron channels and five integral proton channels from which can be deduced four differential proton increments.
An Integrating Dosimeter for Pulsed Radiation,
1983-12-01
obtained using 10 MeV electrons from a linear accelerator and placing the TLDs in an aluminum package equivalent to the thickness of the pin diode * --. and...Radiation Dosimetry System overcomes this problem by electronic - ally integrating the output of a pin diode. The integrator section of the system...for publication. APPROVED: BOBBY L. BUCHANAN, Chief Radiation Hardened Electronics Technology Branch V-. Solid State Sciences Division APPROVED
Robust and Soft Elastomeric Electronics Tolerant to Our Daily Lives.
Sekiguchi, Atsuko; Tanaka, Fumiaki; Saito, Takeshi; Kuwahara, Yuki; Sakurai, Shunsuke; Futaba, Don N; Yamada, Takeo; Hata, Kenji
2015-09-09
Clothes represent a unique textile, as they simultaneously provide robustness against our daily activities and comfort (i.e., softness). For electronic devices to be fully integrated into clothes, the devices themselves must be as robust and soft as the clothes themselves. However, to date, no electronic device has ever possessed these properties, because all contain components fabricated from brittle materials, such as metals. Here, we demonstrate robust and soft elastomeric devices where every component possesses elastomeric characteristics with two types of single-walled carbon nanotubes added to provide the necessary electronic properties. Our elastomeric field effect transistors could tolerate every punishment our clothes experience, such as being stretched (elasticity: ∼ 110%), bent, compressed (>4.0 MPa, by a car and heels), impacted (>6.26 kg m/s, by a hammer), and laundered. Our electronic device provides a novel design principle for electronics and wide range applications even in research fields where devices cannot be used.
X-ray analysis of electron Bernstein wave heating in MST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seltzman, A. H., E-mail: seltzman@wisc.edu; Anderson, J. K.; DuBois, A. M.
2016-11-15
A pulse height analyzing x-ray tomography system has been developed to detect x-rays from electron Bernstein wave heated electrons in the Madison symmetric torus reversed field pinch (RFP). Cadmium zinc telluride detectors are arranged in a parallel beam array with two orthogonal multi-chord detectors that may be used for tomography. In addition a repositionable 16 channel fan beam camera with a 55° field of view is used to augment data collected with the Hard X-ray array. The chord integrated signals identify target emission from RF heated electrons striking a limiter located 12° toroidally away from the RF injection port. Thismore » provides information on heated electron spectrum, transport, and diffusion. RF induced x-ray emission from absorption on harmonic electron cyclotron resonances in low current (<250 kA) RFP discharges has been observed.« less
Fang, Hui; Yu, Ki Jun; Gloschat, Christopher; Yang, Zijian; Chiang, Chia-Han; Zhao, Jianing; Won, Sang Min; Xu, Siyi; Trumpis, Michael; Zhong, Yiding; Song, Enming; Han, Seung Won; Xue, Yeguang; Xu, Dong; Cauwenberghs, Gert; Kay, Matthew; Huang, Yonggang; Viventi, Jonathan; Efimov, Igor R.; Rogers, John A.
2017-01-01
Advanced capabilities in electrical recording are essential for the treatment of heart-rhythm diseases. The most advanced technologies use flexible integrated electronics; however, the penetration of biological fluids into the underlying electronics and any ensuing electrochemical reactions pose significant safety risks. Here, we show that an ultrathin, leakage-free, biocompatible dielectric layer can completely seal an underlying layer of flexible electronics while allowing for electrophysiological measurements through capacitive coupling between tissue and the electronics, and thus without the need for direct metal contact. The resulting current-leakage levels and operational lifetimes are, respectively, four orders of magnitude smaller and between two and three orders of magnitude longer than those of any other flexible-electronics technology. Systematic electrophysiological studies with normal, paced and arrhythmic conditions in Langendorff hearts highlight the capabilities of the capacitive-coupling approach. Our technology provides a realistic pathway towards the broad applicability of biocompatible, flexible electronic implants. PMID:28804678
Multicenter AIDS Cohort Study Quantitative Coronary Plaque Progression Study: rationale and design.
Nakanishi, Rine; Post, Wendy S; Osawa, Kazuhiro; Jayawardena, Eranthi; Kim, Michael; Sheidaee, Nasim; Nezarat, Negin; Rahmani, Sina; Kim, Nicholas; Hathiramani, Nicolai; Susarla, Shriraj; Palella, Frank; Witt, Mallory; Blaha, Michael J; Brown, Todd T; Kingsley, Lawrence; Haberlen, Sabina A; Dailing, Christopher; Budoff, Matthew J
2018-01-01
The association of HIV with coronary atherosclerosis has been established; however, the progression of coronary atherosclerosis over time among participants with HIV is not well known. The Multicenter AIDS Cohort Study Quantitative Coronary Plaque Progression Study is a large prospective multicenter study quantifying progression of coronary plaque assessed by serial coronary computed tomography angiography (CTA). HIV-infected and uninfected men who were enrolled in the Multicenter AIDS Cohort Study Cardiovascular Substudy were eligible to complete a follow-up contrast coronary CTA 3-6 years after baseline. We measured coronary plaque volume and characteristics (calcified and noncalcified plaque including fibrous, fibrous-fatty, and low attenuation) and vulnerable plaque among HIV-infected and uninfected men using semiautomated plaque software to investigate the progression of coronary atherosclerosis over time. We describe a novel, large prospective multicenter study investigating incidence, transition of characteristics, and progression in coronary atherosclerosis quantitatively assessed by serial coronary CTAs among HIV-infected and uninfected men.
Bruland, Philipp; Dugas, Martin
2017-01-07
Data capture for clinical registries or pilot studies is often performed in spreadsheet-based applications like Microsoft Excel or IBM SPSS. Usually, data is transferred into statistic software, such as SAS, R or IBM SPSS Statistics, for analyses afterwards. Spreadsheet-based solutions suffer from several drawbacks: It is generally not possible to ensure a sufficient right and role management; it is not traced who has changed data when and why. Therefore, such systems are not able to comply with regulatory requirements for electronic data capture in clinical trials. In contrast, Electronic Data Capture (EDC) software enables a reliable, secure and auditable collection of data. In this regard, most EDC vendors support the CDISC ODM standard to define, communicate and archive clinical trial meta- and patient data. Advantages of EDC systems are support for multi-user and multicenter clinical trials as well as auditable data. Migration from spreadsheet based data collection to EDC systems is labor-intensive and time-consuming at present. Hence, the objectives of this research work are to develop a mapping model and implement a converter between the IBM SPSS and CDISC ODM standard and to evaluate this approach regarding syntactic and semantic correctness. A mapping model between IBM SPSS and CDISC ODM data structures was developed. SPSS variables and patient values can be mapped and converted into ODM. Statistical and display attributes from SPSS are not corresponding to any ODM elements; study related ODM elements are not available in SPSS. The S2O converting tool was implemented as command-line-tool using the SPSS internal Java plugin. Syntactic and semantic correctness was validated with different ODM tools and reverse transformation from ODM into SPSS format. Clinical data values were also successfully transformed into the ODM structure. Transformation between the spreadsheet format IBM SPSS and the ODM standard for definition and exchange of trial data is feasible. S2O facilitates migration from Excel- or SPSS-based data collections towards reliable EDC systems. Thereby, advantages of EDC systems like reliable software architecture for secure and traceable data collection and particularly compliance with regulatory requirements are achievable.
Conductivity of disordered 2d binodal Dirac electron gas: effect of internode scattering
NASA Astrophysics Data System (ADS)
Sinner, Andreas; Ziegler, Klaus
2018-07-01
We study the dc conductivity of a weakly disordered 2d Dirac electron gas with two bands and two spectral nodes, employing a field theoretical version of the Kubo-Greenwood conductivity formula. In this paper, we are concerned with the question how the internode scattering affects the conductivity. We use and compare two established techniques for treating the disorder scattering: The perturbation theory, there ladder and maximally crossed diagrams are summed up, and the functional integral approach. Both turn out to be entirely equivalent. For a large number of random potential configurations we have found only two different conductivity scenarios. Both scenarios appear independently of whether the disorder does or does not create the internode scattering. In particular, we do not confirm the conjecture that the internode scattering tends to Anderson localisation.
Ohmic contact junction of carbon nanotubes fabricated by in situ electron beam deposition
NASA Astrophysics Data System (ADS)
Wang, Y. G.; Wang, T. H.; Lin, X. W.; Dravid, V. P.
2006-12-01
We present experimental evidence of in situ fabrication of multi-walled carbon nanotube junctions via electron beam induced deposition. The tip-to-tip interconnection of the nanotubes involves the alignment of two nanotubes via a piezodriven nanomanipulator and nano-welding by electron beam deposition. Hydrocarbon contamination from the pump oil vapour of the vacuum system of the TEM chamber was used as the solder; this is superior to the already available metallic solders because its composition is identical to the carbon nanotube. The hydrocarbon deposition, with perfect wettability, on the nanotubes establishes strong mechanical binding between the two nanotubes to form an integrated structure. Consequently, the nanotubes cross-linked by the hydrocarbon solder produce good electrical and mechanical connections. The joint dimension was determined by the size of the electron beam, which results in a sound junction with well-defined geometry and the smallest junction size obtained so far. In situ electric measurement showed a linear current-voltage property for the multi-walled nanotube junction.
Kaltschmidt, Jens; Schmitt, Simon P W; Pruszydlo, Markus G; Haefeli, Walter E
2008-01-01
Electronic mailing systems (e-mail) are an important means to disseminate information within electronic networks. However, in large business communities including the hectic environment of hospitals it may be difficult to induce account holders to read the e-mail. In two mailings disseminated in a large university hospital we evaluated the impact of e-mail layout (three e-mail text versions, two e-mails with graphics) on the willingness of its approximately 6500 recipients to seek additional electronic information and open an integrated link. Overall access rates after 90 days were 21.1 and 23.5% with more than 70% of the respondents opening the link within 3 days. Differences between different layouts were large and artwork text, HTML text, animated GIF, and static image prompted 1.2, 1.7, 1.8, and 2.3 times more often access than the courier plain text message (p
Kaltschmidt, Jens; Schmitt, Simon P.W.; Pruszydlo, Markus G.; Haefeli, Walter E.
2008-01-01
Electronic mailing systems (e-mail) are an important means to disseminate information within electronic networks. However, in large business communities including the hectic environment of hospitals it may be difficult to induce account holders to read the e-mail. In two mailings disseminated in a large university hospital we evaluated the impact of e-mail layout (three e-mail text versions, two e-mails with graphics) on the willingness of its ∼6500 recipients to seek additional electronic information and open an integrated link. Overall access rates after 90 days were 21.1 and 23.5% with more than 70% of the respondents opening the link within 3 days. Differences between different layouts were large and artwork text, HTML text, animated GIF, and static image prompted 1.2, 1.7, 1.8, and 2.3 times more often access than the courier plain text message (p ≤ 0.001). This study revealed that layout is a major determinant of the success of an information campaign. PMID:18096910
Blanchet, Karl; Lewis, James J; Pozo-Martin, Francisco; Satouro, Arsene; Somda, Serge; Ilboudo, Patrick; Sarrassat, Sophie; Cousens, Simon
2016-08-04
Burkina Faso introduced the Integrated Management of Childhood Illnesses (IMCI) strategy in 2003. However, an evaluation conducted in 2013 found that only 28 % of children were assessed for three danger signs as recommended by IMCI, and only 15 % of children were correctly classified. About 30 % of children were correctly prescribed with an antibiotic for suspected pneumonia or oral rehydration salts (ORS) for diarrhoea, and 40 % were correctly referred. Recent advances in information and communication technologies (ICT) and use of electronic clinical protocols hold the potential to transform healthcare delivery in low-income countries. However, no evidence is available on the effect of ICT on adherence to IMCI. This paper describes the research protocol of a mixed methods study that aims to measure the effect of the Integrated electronic Diagnosis Approach innovation (an electronic IMCI protocol provided to nurses) in two regions of Burkina Faso. The study combines a stepped-wedge trial, a realistic evaluation and an economic study in order to capture the effect of the innovation after its introduction on the level of adherence, cost and acceptability. The main challenge is to interconnect the three substudies. In integrating outcome, process and cost data, we focus on three key questions: (i) How does the effectiveness and the cost of the intervention vary by type of health worker and type of health centre? (ii) What is the impact of changes in the content, coverage and quality of the IeDA intervention on adherence and cost-effectiveness? (iii) What mechanisms of change (including costs) might explain the relationship between the IeDA intervention and adherence? Clinicaltrials.gov, NCT02341469 .
Liu, Tongzhou; Zhang, Zhen; Dong, Wenyi; Wu, Xiaojing; Wang, Hongjie
2017-11-01
In this study, the feasibility of employing an integrated bioremediation approach in contaminated river sediment was evaluated. Sequential addition of co-substrate (acetate) and electron acceptor (NO 3 - ) in a two-phase treatment was capable of effectively removing polycyclic aromatic hydrocarbons (PAHs) in river sediment. The residual concentration of total PAHs decreased to far below effect range low (ERL) value within 91 days of incubation, at which concentration it could rarely pose biological impairment. The biodegradation of high molecular weight PAHs were found to be mainly occurred in the sediment treated with co-substrates (i.e. acetate or methanol), in which acetate was found to be more suitable for PAHs degradation. The role of co-substrates in influencing PAHs biodegradation was tentatively discussed herein. Additionally, the sediment odorous problem and blackish appearance were intensively addressed by NO 3 - injection. The results of this study demonstrated that integrating two or more approaches/processes would be a helpful option in sediment remediation. It can lead to a more effective remediation performance, handle multiple contamination issues, as well as mitigate environmental risks caused by one of the single methods. Copyright © 2017 Elsevier Ltd. All rights reserved.
System-Level Integrated Circuit (SLIC) Technology Development for Phased Array Antenna Applications
NASA Technical Reports Server (NTRS)
Windyka, John A.; Zablocki, Ed G.
1997-01-01
This report documents the efforts and progress in developing a 'system-level' integrated circuit, or SLIC, for application in advanced phased array antenna systems. The SLIC combines radio-frequency (RF) microelectronics, digital and analog support circuitry, and photonic interfaces into a single micro-hybrid assembly. Together, these technologies provide not only the amplitude and phase control necessary for electronic beam steering in the phased array, but also add thermally-compensated automatic gain control, health and status feedback, bias regulation, and reduced interconnect complexity. All circuitry is integrated into a compact, multilayer structure configured for use as a two-by-four element phased array module, operating at 20 Gigahertz, using a Microwave High-Density Interconnect (MHDI) process. The resultant hardware is constructed without conventional wirebonds, maintains tight inter-element spacing, and leads toward low-cost mass production. The measured performances and development issues associated with both the two-by-four element module and the constituent elements are presented. Additionally, a section of the report describes alternative architectures and applications supported by the SLIC electronics. Test results show excellent yield and performance of RF circuitry and full automatic gain control for multiple, independent channels. Digital control function, while suffering from lower manufacturing yield, also proved successful.
Chen, Wenjun; Gui, Xuchun; Liang, Binghao; Yang, Rongliang; Zheng, Yongjia; Zhao, Chengchun; Li, Xinming; Zhu, Hai; Tang, Zikang
2017-07-19
Nature-motivated pressure sensors have been greatly important components integrated into flexible electronics and applied in artificial intelligence. Here, we report a high sensitivity, ultrathin, and transparent pressure sensor based on wrinkled graphene prepared by a facile liquid-phase shrink method. Two pieces of wrinkled graphene are face to face assembled into a pressure sensor, in which a porous anodic aluminum oxide (AAO) membrane with the thickness of only 200 nm was used to insulate the two layers of graphene. The pressure sensor exhibits ultrahigh operating sensitivity (6.92 kPa -1 ), resulting from the insulation in its inactive state and conduction under compression. Formation of current pathways is attributed to the contact of graphene wrinkles through the pores of AAO membrane. In addition, the pressure sensor is also an on/off and energy saving device, due to the complete isolation between the two graphene layers when the sensor is not subjected to any pressure. We believe that our high-performance pressure sensor is an ideal candidate for integration in flexible electronics, but also paves the way for other 2D materials to be involved in the fabrication of pressure sensors.
Electronic transport in smectic liquid crystals
NASA Astrophysics Data System (ADS)
Shiyanovskaya, I.; Singer, K. D.; Twieg, R. J.; Sukhomlinova, L.; Gettwert, V.
2002-04-01
Time-of-flight measurements of transient photoconductivity have revealed bipolar electronic transport in phenylnaphthalene and biphenyl liquid crystals (LC), which exhibit several smectic mesophases. In the phenylnaphthalene LC, the hole mobility is significantly higher than the electron mobility and exhibits different temperature and phase behavior. Electron mobility in the range ~10-5 cm2/V s is temperature activated and remains continuous at the phase transitions. However, hole mobility is nearly temperature independent within the smectic phases, but is very sensitive to smectic order, 10-3 cm2/V s in the smectic-B (Sm-B) and 10-4 cm2/V s in the smectic-A (Sm-A) mesophases. The different behavior for holes and electron transport is due to differing transport mechanisms. The electron mobility is apparently controlled by rate-limiting multiple shallow trapping by impurities, but hole mobility is not. To explain the lack of temperature dependence for hole mobility within the smectic phases we consider two possible polaron transport mechanisms. The first mechanism is based on the hopping of Holstein small polarons in the nonadiabatic limit. The polaron binding energy and transfer integral values, obtained from the model fit, turned out to be sensitive to the molecular order in smectic mesophases. A second possible scenario for temperature-independent hole mobility involves the competion between two different polaron mechanisms involving so-called nearly small molecular polarons and small lattice polarons. Although the extracted transfer integrals and binding energies are reasonable and consistent with the model assumptions, the limited temperature range of the various phases makes it difficult to distinguish between any of the models. In the biphenyl LCs both electron and hole mobilities exhibit temperature activated behavior in the range of 10-5 cm2/V s without sensitivity to the molecular order. The dominating transport mechanism is considered as multiple trapping in the impurity sites. Temperature-activated mobility was treated within the disorder formalism, and activation energy and width of density of states have been calculated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garriott, O K
1960-04-01
The results of observations of the radio transmissions from Sputnik III (1958 δ 2) in an 8-month period are presented. The measurements of integrated electron density are made in two ways, described in part 1. The measurements reveal the diurnal variation of the total ionospheric electron content; and the ratio of the total content to the content of the lower ionosphere below the height of maximum density in the F layer is obtained. An estimate of the average electron-density profile above the F-layer peak is made possible by the slow variation in the height of the satellite due to rotationmore » of the perigee position. The gross effects of large magnetic storms on the electron content and distribution are found.« less
Electric microwave absorption for the study of GaAs/AlGaAs heterostructure systems
NASA Astrophysics Data System (ADS)
Zappe, Hans P.; Jantz, Wolfgang
1990-12-01
The use of magnetic-field-dependent microwave absorption as a nondestructive and contact-free means to study transport behavior in GaAs/AlGaAs devices is explored. This technique allows quick measurement of resistance, mobility, and carrier concentration in bulk substrates as well as in the two-dimensional electron gas of heterostructure quantum wells. The two- and three-dimensional conductivities may be separably evaluated, allowing detailed study of conduction in the active layer of high-electron-mobility devices. A brief theoretical foundation is provided, followed by application of the approach to examination of device structural dependencies, carrier-density conduction behavior, and the effects of etch processing on quantum-well integrity.
Enhancing pilot situational awareness of the airport surface movement area
NASA Technical Reports Server (NTRS)
Jones, D. R.; Young, S. D.
1994-01-01
Two studies are being conducted to address airport surface movement area safety and capacity issues by providing enhanced situational awareness information to pilots. One study focuses on obtaining pilot opinion of the Runway Status Light System (RSLS). This system has been designed to reduce the likelihood of runway incursions by informing pilots when a runway is occupied. The second study is a flight demonstration of an rate integrated system consisting of an electronic moving map in the cockpit and display of the aircraft identification to the controller. Taxi route and hold warning information will be sent to the aircraft data link for display on the electronic moving map. This paper describes the plans for the two studies.
Perturbative calculation of two-photon double electron ionization of helium
NASA Astrophysics Data System (ADS)
Ivanov, I. A.; Kheifets, A. S.
2008-05-01
We report the total integrated cross-section (TICS) of two-photon double ionization of helium in the photon energy range from 40 to 54 eV. We compute the TICS in the lowest order perturbation theory (LOPT) using the length and Kramers-Henneberger gauges of the electromagnetic interaction. Our findings indicate that the LOPT gives results for the TICS in agreement with our earlier non-perturbative calculations.
Kazior, Thomas E.
2014-01-01
Advances in silicon technology continue to revolutionize micro-/nano-electronics. However, Si cannot do everything, and devices/components based on other materials systems are required. What is the best way to integrate these dissimilar materials and to enhance the capabilities of Si, thereby continuing the micro-/nano-electronics revolution? In this paper, I review different approaches to heterogeneously integrate dissimilar materials with Si complementary metal oxide semiconductor (CMOS) technology. In particular, I summarize results on the successful integration of III–V electronic devices (InP heterojunction bipolar transistors (HBTs) and GaN high-electron-mobility transistors (HEMTs)) with Si CMOS on a common silicon-based wafer using an integration/fabrication process similar to a SiGe BiCMOS process (BiCMOS integrates bipolar junction and CMOS transistors). Our III–V BiCMOS process has been scaled to 200 mm diameter wafers for integration with scaled CMOS and used to fabricate radio-frequency (RF) and mixed signals circuits with on-chip digital control/calibration. I also show that RF microelectromechanical systems (MEMS) can be integrated onto this platform to create tunable or reconfigurable circuits. Thus, heterogeneous integration of III–V devices, MEMS and other dissimilar materials with Si CMOS enables a new class of high-performance integrated circuits that enhance the capabilities of existing systems, enable new circuit architectures and facilitate the continued proliferation of low-cost micro-/nano-electronics for a wide range of applications. PMID:24567473
Kazior, Thomas E
2014-03-28
Advances in silicon technology continue to revolutionize micro-/nano-electronics. However, Si cannot do everything, and devices/components based on other materials systems are required. What is the best way to integrate these dissimilar materials and to enhance the capabilities of Si, thereby continuing the micro-/nano-electronics revolution? In this paper, I review different approaches to heterogeneously integrate dissimilar materials with Si complementary metal oxide semiconductor (CMOS) technology. In particular, I summarize results on the successful integration of III-V electronic devices (InP heterojunction bipolar transistors (HBTs) and GaN high-electron-mobility transistors (HEMTs)) with Si CMOS on a common silicon-based wafer using an integration/fabrication process similar to a SiGe BiCMOS process (BiCMOS integrates bipolar junction and CMOS transistors). Our III-V BiCMOS process has been scaled to 200 mm diameter wafers for integration with scaled CMOS and used to fabricate radio-frequency (RF) and mixed signals circuits with on-chip digital control/calibration. I also show that RF microelectromechanical systems (MEMS) can be integrated onto this platform to create tunable or reconfigurable circuits. Thus, heterogeneous integration of III-V devices, MEMS and other dissimilar materials with Si CMOS enables a new class of high-performance integrated circuits that enhance the capabilities of existing systems, enable new circuit architectures and facilitate the continued proliferation of low-cost micro-/nano-electronics for a wide range of applications.
System and method for interfacing large-area electronics with integrated circuit devices
Verma, Naveen; Glisic, Branko; Sturm, James; Wagner, Sigurd
2016-07-12
A system and method for interfacing large-area electronics with integrated circuit devices is provided. The system may be implemented in an electronic device including a large area electronic (LAE) device disposed on a substrate. An integrated circuit IC is disposed on the substrate. A non-contact interface is disposed on the substrate and coupled between the LAE device and the IC. The non-contact interface is configured to provide at least one of a data acquisition path or control path between the LAE device and the IC.
Current concepts in cleft care: A multicenter analysis.
Thiele, Oliver C; Kreppel, Matthias; Dunsche, Anton; Eckardt, Andre M; Ehrenfeld, Michael; Fleiner, Bernd; Gaßling, Volker; Gehrke, Gerd; Gerressen, Marcus; Gosau, Martin; Gröbe, Alexander; Haßfeld, Stefan; Heiland, Max; Hoffmeister, Bodo; Hölzle, Frank; Klein, Cornelius; Krüger, Maximilian; Kübler, Alexander C; Kübler, Norbert R; Kuttenberger, Johannes J; Landes, Constantin; Lauer, Günter; Martini, Markus; Merholz, Erich T; Mischkowski, Robert A; Al-Nawas, Bilal; Nkenke, Emeka; Piesold, Jörn U; Pradel, Winnie; Rasse, Michael; Rachwalski, Martin; Reich, Rudolf H; Rothamel, Daniel; Rustemeyer, Jan; Scheer, Martin; Schliephake, Henning; Schmelzeisen, Rainer; Schramm, Alexander; Schupp, Wiebke; Spitzer, Wolfgang J; Stocker, Erwin; Stoll, Christian; Terheyden, Hendrik; Voigt, Alexander; Wagner, Wilfried; Weingart, Dieter; Werkmeister, Richard; Wiltfang, Jörg; Ziegler, Christoph M; Zöller, Joachim E
2018-04-01
The current surgical techniques used in cleft repair are well established, but different centers use different approaches. To determine the best treatment for patients, a multi-center comparative study is required. In this study, we surveyed all craniofacial departments registered with the German Society of Maxillofacial Surgery to determine which cleft repair techniques are currently in use. Our findings revealed much variation in cleft repair between different centers. Although most centers did use a two-stage approach, the operative techniques and timing of lip and palate closure were different in every center. This shows that a retrospective comparative analysis of patient outcome between the participating centers is not possible and illustrates the need for prospective comparative studies to establish the optimal technique for reconstructive cleft surgery. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Bouamrane, Matt-Mouley; Mair, Frances S
2014-11-19
Effective surgical pre-assessment will depend upon the collection of relevant medical information, good data management and communication between the members of the preoperative multi-disciplinary team. NHS Greater Glasgow and Clyde has implemented an electronic preoperative integrated care pathway (eForm) allowing all hospitals to access a comprehensive patient medical history via a clinical portal on the health-board intranet. We conducted six face-to-face semi-structured interviews and participated in one focus group and two workshops with key stakeholders involved in the Planned Care Improvement (PCIP) and Electronic Patient Record programmes. We used qualitative methods and Normalisation Process Theory in order to identify the key factors which led to the successful deployment of the preoperative eForm in the health-board. In January 2013, more than 90,000 patient preoperative assessments had been completed via the electronic portal. Two complementary strategic efforts were instrumental in the successful deployment of the preoperative eForm. At the local health-board level: the PCIP led to the rationalisation of surgical pre-assessment clinics and the standardisation of preoperative processes. At the national level: the eHealth programme selected portal technology as an iterative strategic technology solution towards a virtual electronic patient record. Our study has highlighted clear synergies between these two standardisation efforts. The adoption of the eForm into routine preoperative work practices can be attributed to: (i) a policy context - including performance targets - promoting the rationalisation of surgical pre-assessment pathways, (ii) financial and organisational resources to support service redesign and the use of information technology for operationalising the standardisation of preoperative processes, (iii) a sustained engagement with stakeholders throughout the iterative phases of the preoperative clinics redesign, guidelines standardisation and the eForm development, (iv) the use of a pragmatic and domain-agnostic technology solution and finally: (v) a consensual and contextualised implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Zhaojun; Ma, Jun; Huang, Tongde
2014-03-03
In this Letter, we report selective epitaxial growth of monolithically integrated GaN-based light emitting diodes (LEDs) with AlGaN/GaN high-electron-mobility transistor (HEMT) drivers. A comparison of two integration schemes, selective epitaxial removal (SER), and selective epitaxial growth (SEG) was made. We found the SER resulted in serious degradation of the underlying LEDs in a HEMT-on-LED structure due to damage of the p-GaN surface. The problem was circumvented using the SEG that avoided plasma etching and minimized device degradation. The integrated HEMT-LEDs by SEG exhibited comparable characteristics as unintegrated devices and emitted modulated blue light by gate biasing.
Ahmed, Shabnam; Al-Mously, Najwa; Al-Senani, Fahmi; Zafar, Muhammad; Ahmed, Muhammad
2016-01-01
This study aims to evaluate the perception of medical teachers toward the integration of simulation-based medical education (SBME) in undergraduate curriculum and also identify contextual barriers faced by medical teachers. This cross-sectional observational study included medical teachers from three universities. A questionnaire was used to report teachers' perception. SBME was perceived by medical teachers (basic sciences/clinical, respectively) as enjoyable (71.1%/75.4%), effective assessment tool to evaluate students' learning (60%/73.9%) and can improve learning outcome (88.8%/79.7%). Similarly, (91.1%/71%) of teachers think that simulation should be part of the curriculum and not stand alone one time activity. Teachers' training for SBME has created a significant difference in perception (p < 0.05). Lack of teachers' training, time, resources and the need to integrate in medical curriculum are major perceived barriers for effective SBME. Results highlight the positive perception and attitude of medical teachers toward the integration of SBME in undergraduate curriculum. Prior formal training of teachers created a different perception. Top perceived barriers for effective SBME include teachers' formal training supported with time and resources and the early integration into the curriculum. These critical challenges need to be addressed by medical schools in order to enhance the integration SBME in undergraduate curricula.
HDU Pressurized Excursion Module (PEM) Prototype Systems Integration
NASA Technical Reports Server (NTRS)
Gill, Tracy R.; Kennedy, Kriss; Tri, Terry; Toups, Larry; Howe, A. Scott
2010-01-01
The Habitat Demonstration Unit (HDU) project team constructed an analog prototype lunar surface laboratory called the Pressurized Excursion Module (PEM). The prototype unit subsystems were integrated in a short amount of time, utilizing a skunk-works approach that brought together over 20 habitation-related technologies from a variety of NASA centers. This paper describes the system integration strategies and lessons learned, that allowed the PEM to be brought from paper design to working field prototype using a multi-center team. The system integration process included establishment of design standards, negotiation of interfaces between subsystems, and scheduling fit checks and installation activities. A major tool used in integration was a coordinated effort to accurately model all the subsystems using CAD, so that conflicts were identified before physical components came together. Some of the major conclusions showed that up-front modularity that emerged as an artifact of construction, such as the eight 45 degree "pie slices" making up the module whose steel rib edges defined structural mounting and loading points, dictated much of the configurational interfaces between the major subsystems and workstations. Therefore, 'one of the lessons learned included the need to use modularity as a tool for organization in advance, and to work harder to prevent non-critical aspects of the platform from dictating the modularity that may eventually inform the fight system.
Advanced electronic displays and their potential in future transport aircraft
NASA Technical Reports Server (NTRS)
Hatfield, J. J.
1981-01-01
It is pointed out that electronic displays represent one of the keys to continued integration and improvement of the effectiveness of avionic systems in future transport aircraft. An employment of modern electronic display media and generation has become vital in connection with the increases in modes and functions of modern aircraft. Requirements for electronic systems of future transports are examined, and a description is provided of the tools which are available for cockpit integration, taking into account trends in information processing and presentation, trends in integrated display devices, and trends concerning input/output devices. Developments related to display media, display generation, and I/O devices are considered, giving attention to a comparison of CRT and flat-panel display technology, advanced HUD technology and multifunction controls. Integrated display formats are discussed along with integrated systems and cockpit configurations.
Velocity time integral for right upper pulmonary vein in VLBW infants with patent ductus arteriosus.
Lista, Gianluca; Bianchi, Silvia; Mannarino, Savina; Schena, Federico; Castoldi, Francesca; Stronati, Mauro; Mosca, Fabio
2016-10-01
Early diagnosis of significant patent ductus arteriosus reduces the risk of clinical worsening in very low birth weight infants. Echocardiographic patent ductus arteriosus shunt flow pattern can be used to predict significant patent ductus arteriosus. Pulmonary venous flow, expressed as vein velocity time integral, is correlated to ductus arteriosus closure. The aim of this study is to investigate the relationship between significant reductions in vein velocity time integral and non-significant patent ductus arteriosus in the first week of life. A multicenter, prospective, observational study was conducted to evaluate very low birth weight infants (<1500 g) on respiratory support. Echocardiography was used to evaluate vein velocity time integral on days 1 and 4 of life. The relationship between vein velocity time integral and other parameters was studied. In total, 98 very low birth weight infants on respiratory support were studied. On day 1 of life, vein velocity time integral was similar in patients with open or closed ductus. The mean vein velocity time integral significantly reduced in the first four days of life. On the fourth day of life, there was less of a reduction in patients with patent ductus compared to those with closed patent ductus arteriosus and the difference was significant. A significant reduction in vein velocity time integral in the first days of life is associated with ductus closure. This parameter correlates well with other echocardiographic parameters and may aid in the diagnosis and management of patent ductus arteriosus.
Archetype-based semantic integration and standardization of clinical data.
Moner, David; Maldonado, Jose A; Bosca, Diego; Fernandez, Jesualdo T; Angulo, Carlos; Crespo, Pere; Vivancos, Pedro J; Robles, Montserrat
2006-01-01
One of the basic needs for any healthcare professional is to be able to access to clinical information of patients in an understandable and normalized way. The lifelong clinical information of any person supported by electronic means configures his/her Electronic Health Record (EHR). This information is usually distributed among several independent and heterogeneous systems that may be syntactically or semantically incompatible. The Dual Model architecture has appeared as a new proposal for maintaining a homogeneous representation of the EHR with a clear separation between information and knowledge. Information is represented by a Reference Model which describes common data structures with minimal semantics. Knowledge is specified by archetypes, which are formal representations of clinical concepts built upon a particular Reference Model. This kind of architecture is originally thought for implantation of new clinical information systems, but archetypes can be also used for integrating data of existing and not normalized systems, adding at the same time a semantic meaning to the integrated data. In this paper we explain the possible use of a Dual Model approach for semantic integration and standardization of heterogeneous clinical data sources and present LinkEHR-Ed, a tool for developing archetypes as elements for integration purposes. LinkEHR-Ed has been designed to be easily used by the two main participants of the creation process of archetypes for clinical data integration: the Health domain expert and the Information Technologies domain expert.
"Green" electronics: biodegradable and biocompatible materials and devices for sustainable future.
Irimia-Vladu, Mihai
2014-01-21
"Green" electronics represents not only a novel scientific term but also an emerging area of research aimed at identifying compounds of natural origin and establishing economically efficient routes for the production of synthetic materials that have applicability in environmentally safe (biodegradable) and/or biocompatible devices. The ultimate goal of this research is to create paths for the production of human- and environmentally friendly electronics in general and the integration of such electronic circuits with living tissue in particular. Researching into the emerging class of "green" electronics may help fulfill not only the original promise of organic electronics that is to deliver low-cost and energy efficient materials and devices but also achieve unimaginable functionalities for electronics, for example benign integration into life and environment. This Review will highlight recent research advancements in this emerging group of materials and their integration in unconventional organic electronic devices.
A Demonstration Advanced Avionics System for general aviation
NASA Technical Reports Server (NTRS)
Denery, D. G.; Callas, G. P.; Jackson, C. T.; Berkstresser, B. K.; Hardy, G. H.
1979-01-01
A program initiated within NASA has emphasized the use of a data bus, microprocessors, electronic displays and data entry devices for general aviation. A Demonstration Advanced Avionics System (DAAS) capable of evaluating critical and promising elements of an integrating system that will perform the functions of (1) automated guidance and navigation; (2) flight planning; (3) weight and balance performance computations; (4) monitoring and warning; and (5) storage of normal and emergency check lists and operational limitations is described. Consideration is given to two major parts of the DAAS instrument panel: the integrated data control center and an electronic horizontal situation indicator, and to the system architecture. The system is to be installed in the Ames Research Center's Cessna 402B in the latter part of 1980; engineering flight testing will begin in the first part of 1981.
Characterization of Sphinx1 ASIC X-ray detector using photon counting and charge integration
NASA Astrophysics Data System (ADS)
Habib, A.; Arques, M.; Moro, J.-L.; Accensi, M.; Stanchina, S.; Dupont, B.; Rohr, P.; Sicard, G.; Tchagaspanian, M.; Verger, L.
2018-01-01
Sphinx1 is a novel pixel architecture adapted for X-ray imaging, it detects radiation by photon counting and charge integration. In photon counting mode, each photon is compensated by one or more counter-charges typically consisting of 100 electrons (e-) each. The number of counter-charges required gives a measure of the incoming photon energy, thus allowing spectrometric detection. Pixels can also detect radiation by integrating the charges deposited by all incoming photons during one image frame and converting this analog value into a digital response with a 100 electrons least significant bit (LSB), based on the counter-charge concept. A proof of concept test chip measuring 5 mm × 5 mm, with 200 μm × 200 μm pixels has been produced and characterized. This paper provides details on the architecture and the counter-charge design; it also describes the two modes of operation: photon counting and charge integration. The first performance measurements for this test chip are presented. Noise was found to be ~80 e-rms in photon counting mode with a power consumption of only 0.9 μW/pixel for the static analog part and 0.3 μW/pixel for the static digital part.
ERIC Educational Resources Information Center
Greenhill, Laurence L.; Muniz, Rafael; Ball, Roberta R.; Levine, Alan; Pestreich, Linda; Jiang, Hai
2006-01-01
Objective: The efficacy and safety of dexmethylphenidate extended release (d-MPH-ER) was compared to placebo in pediatric patients with attention-deficit/hyperactivity disorder (ADHD). Method: This multicenter, randomized, double-blind, placebo-controlled, parallel-group, two-phase study included 97 patients (ages 6-17 years) with…
Method for integrating microelectromechanical devices with electronic circuitry
Montague, Stephen; Smith, James H.; Sniegowski, Jeffry J.; McWhorter, Paul J.
1998-01-01
A method for integrating one or more microelectromechanical (MEM) devices with electronic circuitry. The method comprises the steps of forming each MEM device within a cavity below a device surface of the substrate; encapsulating the MEM device prior to forming electronic circuitry on the substrate; and releasing the MEM device for operation after fabrication of the electronic circuitry. Planarization of the encapsulated MEM device prior to formation of the electronic circuitry allows the use of standard processing steps for fabrication of the electronic circuitry.
A molecular shift register based on electron transfer
NASA Technical Reports Server (NTRS)
Hopfield, J. J.; Onuchic, Josenelson; Beratan, David N.
1988-01-01
An electronic shift-register memory at the molecular level is described. The memory elements are based on a chain of electron-transfer molecules and the information is shifted by photoinduced electron-transfer reactions. This device integrates designed electronic molecules onto a very large scale integrated (silicon microelectronic) substrate, providing an example of a 'molecular electronic device' that could actually be made. The design requirements for such a device and possible synthetic strategies are discussed. Devices along these lines should have lower energy usage and enhanced storage density.
Basch, Ethan; Pugh, Stephanie L; Dueck, Amylou C; Mitchell, Sandra A; Berk, Lawrence; Fogh, Shannon; Rogak, Lauren J; Gatewood, Marcha; Reeve, Bryce B; Mendoza, Tito R; O’Mara, Ann; Denicoff, Andrea; Minasian, Lori; Bennett, Antonia V; Setser, Ann; Schrag, Deborah; Roof, Kevin; Moore, Joan K; Gergel, Thomas; Stephans, Kevin; Rimner, Andreas; DeNittis, Albert; Bruner, Deborah Watkins
2017-01-01
Purpose To assess the feasibility of measuring symptomatic adverse events (AEs) in a multicenter clinical trial using the National Cancer Institute’s Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events (PRO-CTCAE). Methods and Materials Patients enrolled in Trial XXXX (XXXX) were asked to self-report 53 PRO-CTCAE items representing 30 symptomatic AEs at 6 time points (baseline; weekly x4 during treatment; 12-weeks post-treatment). Reporting was conducted via wireless tablet computers in clinic waiting areas. Compliance was defined as the proportion of visits when an expected PRO-CTCAE assessment was completed. Results Among 226 study sites participating in Trial XXXX, 100% completed 35-minute PRO-CTCAE training for clinical research associates (CRAs); 80 sites enrolled patients of which 34 (43%) required tablet computers to be provided. All 152 patients in Trial XXXX agreed to self-report using the PRO-CTCAE (median age 66; 47% female; 84% white). Median time for CRAs to learn the system was 60 minutes (range 30–240), and median time for CRAs to teach a patient to self-report was 10 minutes (range 2–60). Compliance was high, particularly during active treatment when patients self-reported at 86% of expected time points, although compliance was lower post-treatment (72%). Common reasons for non-compliance were institutional errors such as forgetting to provide computers to participants; patients missing clinic visits; internet connectivity; and patients feeling “too sick”. Conclusions Most patients enrolled in a multicenter chemoradiotherapy trial were willing and able to self-report symptomatic adverse events at visits using tablet computers. Minimal effort was required by local site staff to support this system. The observed causes of missing data may be obviated by allowing patients to self-report electronically between-visits, and by employing central compliance monitoring. These approaches are being incorporated into ongoing studies. PMID:28463161
Integration and test of high-speed transmitter electronics for free-space laser communications
NASA Technical Reports Server (NTRS)
Soni, Nitin J.; Lizanich, Paul J.
1994-01-01
The NASA Lewis Research Center in Cleveland, Ohio, has developed the electronics for a free-space, direct-detection laser communications system demonstration. Under the High-Speed Laser Integrated Terminal Electronics (Hi-LITE) Project, NASA Lewis has built a prototype full-duplex, dual-channel electronics transmitter and receiver operating at 325 megabit S per second (Mbps) per channel and using quaternary pulse-position modulation (QPPM). This paper describes the integration and testing of the transmitter portion for future application in free-space, direct-detection laser communications. A companion paper reviews the receiver portion of the prototype electronics. Minor modifications to the transmitter were made since the initial report on the entire system, and this paper addresses them. The digital electronics are implemented in gallium arsenide integrated circuits mounted on prototype boards. The fabrication and implementation issues related to these high-speed devices are discussed. The transmitter's test results are documented, and its functionality is verified by exercising all modes of operation. Various testing issues pertaining to high-speed circuits are addressed. A description of the transmitter electronics packaging concludes the paper.
Autonomous aircraft initiative study
NASA Technical Reports Server (NTRS)
Hewett, Marle D.
1991-01-01
The results of a consulting effort to aid NASA Ames-Dryden in defining a new initiative in aircraft automation are described. The initiative described is a multi-year, multi-center technology development and flight demonstration program. The initiative features the further development of technologies in aircraft automation already being pursued at multiple NASA centers and Department of Defense (DoD) research and Development (R and D) facilities. The proposed initiative involves the development of technologies in intelligent systems, guidance, control, software development, airborne computing, navigation, communications, sensors, unmanned vehicles, and air traffic control. It involves the integration and implementation of these technologies to the extent necessary to conduct selected and incremental flight demonstrations.
On thermalization of electron-positron-photon plasma
NASA Astrophysics Data System (ADS)
Siutsou, I. A.; Aksenov, A. G.; Vereshchagin, G. V.
2015-12-01
Recently a progress has been made in understanding thermalization mechanism of relativistic plasma starting from a non-equilibrium state. Relativistic Boltzmann equations were solved numerically for homogeneous isotropic plasma with collision integrals for two- and three-particle interactions calculated from the first principles by means of QED matrix elements. All particles were assumed to fulfill Boltzmann statistics. In this work we follow plasma thermalization by accounting for Bose enhancement and Pauli blocking in particle interactions. Our results show that particle in equilibrium reach Bose-Einstein distribution for photons, and Fermi-Dirac one for electrons, respectively.
Lamprecht-Dinnesen, A; Sick, U; Sandrieser, P; Illg, A; Lesinski-Schiedat, A; Döring, W H; Müller-Deile, J; Kiefer, J; Matthias, K; Wüst, A; Konradi, E; Riebandt, M; Matulat, P; Von Der Haar-Heise, S; Swart, J; Elixmann, K; Neumann, K; Hildmann, A; Coninx, F; Meyer, V; Gross, M; Kruse, E; Lenarz, T
2002-10-01
Since autumn 1998 the multicenter interdisciplinary study group "Test Materials for CI Children" has been compiling a uniform examination tool for evaluation of speech and hearing development after cochlear implantation in childhood. After studying the relevant literature, suitable materials were checked for practical applicability, modified and provided with criteria for execution and break-off. For data acquisition, observation forms for preparation of a PC-version were developed. The evaluation set contains forms for master data with supplements relating to postoperative processes. The hearing tests check supra-threshold hearing with loudness scaling for children, speech comprehension in silence (Mainz and Göttingen Test for Speech Comprehension in Childhood) and phonemic differentiation (Oldenburg Rhyme Test for Children), the central auditory processes of detection, discrimination, identification and recognition (modification of the "Frankfurt Functional Hearing Test for Children") and audiovisual speech perception (Open Paragraph Tracking, Kiel Speech Track Program). The materials for speech and language development comprise phonetics-phonology, lexicon and semantics (LOGO Pronunciation Test), syntax and morphology (analysis of spontaneous speech), language comprehension (Reynell Scales), communication and pragmatics (observation forms). The MAIS and MUSS modified questionnaires are integrated. The evaluation set serves quality assurance and permits factor analysis as well as controls for regularity through the multicenter comparison of long-term developmental trends after cochlear implantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Breuer, Marian; Zarzycki, Piotr P.; Shi, Liang
2012-12-01
The free energy profile for electron flow through the bacterial deca-heme cytochrome MtrF has been computed using thermodynamic integration and classical molecular dynamics. The extensive calculations on two versions of the structure help validate the method and results, because differences in the profiles can be related to differences in the charged amino acids local to specific heme groups. First estimates of reorganization free energies λ yield a range consistent with expectations for partially solvent exposed cofactors, and reveal an activation energy range surmountable for electron flow. Future work will aim at increasing the accuracy of λ with polarizable force fieldmore » dynamics and quantum chemical energy gap calculations, as well as quantum chemical computation of electronic coupling matrix elements.« less
Bousis, Christos; Emfietzoglou, Dimitris; Nikjoo, Hooshang
2012-12-01
To calculate the absorbed fraction (AF) of low energy electrons in small tissue-equivalent spherical volumes by Monte Carlo (MC) track structure simulation and assess the influence of phase (liquid water versus density-scaled water vapor) and of the continuous-slowing-down approximation (CSDA) used in semi-analytic calculations. An event-by-event MC code simulating the transport of electrons in both the vapor and liquid phase of water using appropriate electron-water interaction cross sections was used to quantify the energy deposition of low-energy electrons in spherical volumes. Semi-analytic calculations within the CSDA using a convolution integral of the Howell range-energy expressions are also presented for comparison. The AF for spherical volumes of radii from 10-1000 nm are presented for monoenergetic electrons over the energy range 100-10,000 eV and the two Auger-emitting radionuclides (125)I and (123)I. The MC calculated AF for the liquid phase are found to be smaller than those of the (density scaled) gas phase by up to 10-20% for the monoenergetic electrons and 10% for the two Auger-emitters. Differences between the liquid-phase MC results and the semi-analytic CSDA calculations are up to ∼ 55% for the monoenergetic electrons and up to ∼ 35% for the two Auger-emitters. Condensed-phase effects in the inelastic interaction of low-energy electrons with water have a noticeable but relatively small impact on the AF for the energy range and target sizes examined. Depending on the electron energies, the semi-analytic approach may lead to sizeable errors for target sizes with linear dimensions below 1 micron.
Integration of clinical research documentation in electronic health records.
Broach, Debra
2015-04-01
Clinical trials of investigational drugs and devices are often conducted within healthcare facilities concurrently with clinical care. With implementation of electronic health records, new communication methods are required to notify nonresearch clinicians of research participation. This article reviews clinical research source documentation, the electronic health record and the medical record, areas in which the research record and electronic health record overlap, and implications for the research nurse coordinator in documentation of the care of the patient/subject. Incorporation of clinical research documentation in the electronic health record will lead to a more complete patient/subject medical record in compliance with both research and medical records regulations. A literature search provided little information about the inclusion of clinical research documentation within the electronic health record. Although regulations and guidelines define both source documentation and the medical record, integration of research documentation in the electronic health record is not clearly defined. At minimum, the signed informed consent(s), investigational drug or device usage, and research team contact information should be documented within the electronic health record. Institutional policies should define a standardized process for this integration in the absence federal guidance. Nurses coordinating clinical trials are in an ideal position to define this integration.
Keitel, Kristina; D'Acremont, Valérie
2018-04-20
The lack of effective, integrated diagnostic tools pose a major challenge to the primary care management of febrile childhood illnesses. These limitations are especially evident in low-resource settings and are often inappropriately compensated by antimicrobial over-prescription. Interactive electronic decision trees (IEDTs) have the potential to close these gaps: guiding antibiotic use and better identifying serious disease. This narrative review summarizes existing IEDTs, to provide an overview of their degree of validation, as well as to identify gaps in current knowledge and prospects for future innovation. Structured literature review in PubMed and Embase complemented by google search and contact with developers. Six integrated IEDTs were identified: three (eIMCI, REC, and Bangladesh digital IMCI) based on Integrated Management of Childhood Illnesses (IMCI); four (SL eCCM, MEDSINC, e-iCCM, and D-Tree eCCM) on Integrated Community Case Management (iCCM); two (ALMANACH, MSFeCARE) with a modified IMCI content; and one (ePOCT) that integrates novel content with biomarker testing. The types of publications and evaluation studies varied greatly: the content and evidence-base was published for two (ALMANACH and ePOCT), ALMANACH and ePOCT were validated in efficacy studies. Other types of evaluations, such as compliance, acceptability were available for D-Tree eCCM, eIMCI, ALMANACH. Several evaluations are still ongoing. Future prospects include conducting effectiveness and impact studies using data gathered through larger studies to adapt the medical content to local epidemiology, improving the software and sensors, and Assessing factors that influence compliance and scale-up. IEDTs are valuable tools that have the potential to improve management of febrile children in primary care and increase the rational use of diagnostics and antimicrobials. Next steps in the evidence pathway should be larger effectiveness and impact studies (including cost analysis) and continuous integration of clinically useful diagnostic and treatment innovations. Copyright © 2018. Published by Elsevier Ltd.
Innovative Pressure Sensor Platform and Its Integration with an End-User Application
Flores-Caballero, Antonio; Copaci, Dorin; Blanco, María Dolores; Moreno, Luis; Herrán, Jaime; Fernández, Iván; Ochoteco, Estíbaliz; Cabañero, German; Grande, Hans
2014-01-01
This paper describes the fully integration of an innovative and low-cost pressure sensor sheet based on a bendable and printed electronics technology. All integration stages are covered, from most low-level functional system, like physical analog sensor data acquisition, followed by embedded data processing, to end user interactive visual application. Data acquisition embedded software and hardware was developed using a Rapid Control Prototyping (RCP). Finally, after first electronic prototype successful testing, a Taylor-made electronics was developed, reducing electronics volume to 3.5 cm × 6 cm × 2 cm with a maximum power consumption of 765 mW for both electronics and pressure sensor sheet. PMID:24922455
Prediction Model for Relativistic Electrons at Geostationary Orbit
NASA Technical Reports Server (NTRS)
Khazanov, George V.; Lyatsky, Wladislaw
2008-01-01
We developed a new prediction model for forecasting relativistic (greater than 2MeV) electrons, which provides a VERY HIGH correlation between predicted and actually measured electron fluxes at geostationary orbit. This model implies the multi-step particle acceleration and is based on numerical integrating two linked continuity equations for primarily accelerated particles and relativistic electrons. The model includes a source and losses, and used solar wind data as only input parameters. We used the coupling function which is a best-fit combination of solar wind/interplanetary magnetic field parameters, responsible for the generation of geomagnetic activity, as a source. The loss function was derived from experimental data. We tested the model for four year period 2004-2007. The correlation coefficient between predicted and actual values of the electron fluxes for whole four year period as well as for each of these years is stable and incredibly high (about 0.9). The high and stable correlation between the computed and actual electron fluxes shows that the reliable forecasting these electrons at geostationary orbit is possible.
Relativistic Electrons at Geostationary Orbit: Modeling Results
NASA Technical Reports Server (NTRS)
Khazanov, George V.; Lyatsky, Wladislaw
2008-01-01
We developed a new prediction model for forecasting relativistic (greater than 2MeV) electrons, which provides a VERY HIGH correlation between predicted and actually measured electron fluxes at geostationary orbit. This model implies the multi-step particle acceleration and is based on numerical integrating two linked continuity equations for primarily accelerated particles and relativistic electrons. The model includes a source and losses, and used solar wind data as only input parameters. We used the coupling function which is a best-fit combination of solar wind/interplanetary magnetic field parameters, responsible for the generation of geomagnetic activity, as a source. The loss function was derived from experimental data. We tested the model for four year period 2004-2007. The correlation coefficient between predicted and actual values of the electron fluxes for whole four year period as well as for each of these years is stable and incredibly high (about 0.9). The high and stable correlation between the computed and actual electron fluxes shows that the reliable forecasting these electrons at geostationary orbit is possible.
Building Your Own Web Course: The Case for Off-the-Shelf Component Software.
ERIC Educational Resources Information Center
Kaplan, Howard
1998-01-01
Compares the features, advantages, and disadvantages of two major software options available for designing web courses: (1) component, off-the shelf software that allows for creation of audio slide lectures, course materials, discussion forums, animations, synchronous chat groups, quiz creators, and electronic mail, and (2) integrated packages…
A CMOS VLSI IC for Real-Time Opto-Electronic Two-Dimensional Histogram Generation
1993-12-01
large scale integration) design; MAGIC ; CMOS; optics; image processing; 93 16. PRICE CODE 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATiON 19...1. Sun SPARCstation ............. .............. 6 2. Magic .................. ................... 6 a. Peg ................. .................. 7 b...38 v APPENDIX B. MAGIC CELL LAYOUTS .... ............ .. 39 APPENDIX C: SIMULATION DATA ....... ............. .. 56 A. FINITE STATE MACHINE
Biases of Communication Systems: An Exploratory Approach to Studying New Communication Technologies.
ERIC Educational Resources Information Center
Krendl, Kathy A.; Fredin, Eric S.
This field experiment begins to build a theoretical framework for exploring the effects of media characteristics on subjects' understanding and integration of information. Students in two eighth-grade science classes wrote term papers with one class using a print encyclopedia and the other an electronic encyclopedia to conduct their research. A…
Intelligent on-board system for driving assistance
NASA Astrophysics Data System (ADS)
Rombaut, Michele; Le Fort-Piat, N.
1995-09-01
We present in this paper, an electronic copilot embedded in a real car. The system objective is to help the driver by sending alarms or warnings in order to avoid dangerous situtations. An onboard perception system based on CCD cameras and proprioceptive sensors is used ot provide information concerning the environment and the internal state of the vehicle. From this set of information, the copilot is able to analyze the situation and to generate adequate warnings to the driver according to the circumstances. The definition and the development of such a system deal with multisensor data fusion and supervision strategies. The framework of this work was the European Prometheus Pro-Art program. The electronic copilot has been integrated in a prototype vehicle called Prolab2. This French demonstrator integrates the works of nine research laboratories and two car companies: PSA and RENAULT. After a brief presentation of the global demonstrator, we present the two principal parts developed in our laboratory corresponding to the high level modules of the system: the dynamic data manager and the situation supervision.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Di-Cheng; Pan, You-Wei; Lin, Shih-Wei
2016-04-25
We demonstrate experimentally the two-terminal magnetic sensors exhibiting an extraordinary magneto-resistance effect by using an InGaAs quantum well channel with a metal-shunting structure. A high magneto-resistance of 17.3% and a sensitivity of 488.1 Ω/T have been obtained at 1 T and room temperature with our geometrical design. The two-contact configuration and the high-mobility electron transistor-compatible epitaxy structure make the devices promising for high-sensitivity magnetic sensing integration and applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gomez, Thomas; Nagayama, Taisuke; Fontes, Chris
Atomic structure of N-electron atoms is often determined by solving the Hartree-Fock equations, which are a set of integro-differential equations. The integral part of the Hartree-Fock equations treats electron exchange, but the Hartree-Fock equations are not often treated as an integro-differential equation. The exchange term is often approximated as an inhomogeneous or an effective potential so that the Hartree-Fock equations become a set of ordinary differential equations (which can be solved using the usual shooting methods). Because the Hartree-Fock equations are an iterative-refinement method, the inhomogeneous term relies on the previous guess of the wavefunction. In addition, there are numericalmore » complications associated with solving inhomogeneous differential equations. This work uses matrix methods to solve the Hartree-Fock equations as an integro-differential equation. It is well known that a derivative operator can be expressed as a matrix made of finite-difference coefficients; energy eigenvalues and eigenvectors can be obtained by using linear-algebra packages. The integral (exchange) part of the Hartree-Fock equation can be approximated as a sum and written as a matrix. The Hartree-Fock equations can be solved as a matrix that is the sum of the differential and integral matrices. We compare calculations using this method against experiment and standard atomic structure calculations. This matrix method can also be used to solve for free-electron wavefunctions, thus improving how the atoms and free electrons interact. Here, this technique is important for spectral line broadening in two ways: it improves the atomic structure calculations, and it improves the motion of the plasma electrons that collide with the atom.« less
Gomez, Thomas; Nagayama, Taisuke; Fontes, Chris; ...
2018-04-23
Atomic structure of N-electron atoms is often determined by solving the Hartree-Fock equations, which are a set of integro-differential equations. The integral part of the Hartree-Fock equations treats electron exchange, but the Hartree-Fock equations are not often treated as an integro-differential equation. The exchange term is often approximated as an inhomogeneous or an effective potential so that the Hartree-Fock equations become a set of ordinary differential equations (which can be solved using the usual shooting methods). Because the Hartree-Fock equations are an iterative-refinement method, the inhomogeneous term relies on the previous guess of the wavefunction. In addition, there are numericalmore » complications associated with solving inhomogeneous differential equations. This work uses matrix methods to solve the Hartree-Fock equations as an integro-differential equation. It is well known that a derivative operator can be expressed as a matrix made of finite-difference coefficients; energy eigenvalues and eigenvectors can be obtained by using linear-algebra packages. The integral (exchange) part of the Hartree-Fock equation can be approximated as a sum and written as a matrix. The Hartree-Fock equations can be solved as a matrix that is the sum of the differential and integral matrices. We compare calculations using this method against experiment and standard atomic structure calculations. This matrix method can also be used to solve for free-electron wavefunctions, thus improving how the atoms and free electrons interact. Here, this technique is important for spectral line broadening in two ways: it improves the atomic structure calculations, and it improves the motion of the plasma electrons that collide with the atom.« less
Zhang, Hai-Bo; Zhang, Xiang-Liang; Wang, Yong; Takaoka, Akio
2007-01-01
The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO(2) film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view of elastic scattering of electrons, showing that linear attenuation of the logarithmic electron transmission still holds valid for effective specimen thicknesses up to 5 microm under 2 MV accelerating voltages. Electron tomography of a micron-order thick integrated circuit specimen including the Cu/via interconnect was then tried with 3 MeV electrons in the ultra-HVEM. Serial projection images of the specimen tilted at different angles over the range of +/-90 degrees were acquired, and 3D reconstruction was performed with the images by means of the IMOD software package. Consequently, the 3D structures of the Cu lines, via and void, were revealed by cross sections and surface rendering.
Biomedical Diagnostics Enabled by Integrated Organic and Printed Electronics.
Ahmadraji, Termeh; Gonzalez-Macia, Laura; Ritvonen, Tapio; Willert, Andreas; Ylimaula, Satu; Donaghy, David; Tuurala, Saara; Suhonen, Mika; Smart, Dave; Morrin, Aoife; Efremov, Vitaly; Baumann, Reinhard R; Raja, Munira; Kemppainen, Antti; Killard, Anthony J
2017-07-18
Organic and printed electronics integration has the potential to revolutionize many technologies, including biomedical diagnostics. This work demonstrates the successful integration of multiple printed electronic functionalities into a single device capable of the measurement of hydrogen peroxide and total cholesterol. The single-use device employed printed electrochemical sensors for hydrogen peroxide electroreduction integrated with printed electrochromic display and battery. The system was driven by a conventional electronic circuit designed to illustrate the complete integration of silicon integrated circuits via pick and place or using organic electronic circuits. The device was capable of measuring 8 μL samples of both hydrogen peroxide (0-5 mM, 2.72 × 10 -6 A·mM -1 ) and total cholesterol in serum from 0 to 9 mM (1.34 × 10 -8 A·mM -1 , r 2 = 0.99, RSD < 10%, n = 3), and the result was output on a semiquantitative linear bar display. The device could operate for 10 min via a printed battery, and display the result for many hours or days. A mobile phone "app" was also capable of reading the test result and transmitting this to a remote health care provider. Such a technology could allow improved management of conditions such as hypercholesterolemia.
Code of Federal Regulations, 2013 CFR
2013-07-01
... combination of electronic hardware and software integrated in a variety of forms (firmware, programmable... electronic hardware and computer software integrated in a variety of forms (firmware, programmable software...
Code of Federal Regulations, 2011 CFR
2011-07-01
... combination of electronic hardware and software integrated in a variety of forms (firmware, programmable... electronic hardware and computer software integrated in a variety of forms (firmware, programmable software...
Code of Federal Regulations, 2014 CFR
2014-07-01
... combination of electronic hardware and software integrated in a variety of forms (firmware, programmable... electronic hardware and computer software integrated in a variety of forms (firmware, programmable software...
Code of Federal Regulations, 2012 CFR
2012-07-01
... combination of electronic hardware and software integrated in a variety of forms (firmware, programmable... electronic hardware and computer software integrated in a variety of forms (firmware, programmable software...
Bartolo, Michelangelo; Bargellesi, Stefano; Castioni, Carlo A; Bonaiuti, Donatella; Antenucci, Roberto; Benedetti, Angelo; Capuzzo, Valeria; Gamna, Federica; Radeschi, Giulio; Citerio, Giuseppe; Colombo, Carolina; Del Casale, Laura; Recubini, Elena; Toska, Saimir; Zanello, Marco; D'Aurizio, Carlo; Spina, Tullio; Del Gaudio, Alredo; Di Rienzo, Filomena; Intiso, Domenico; Dallocchio, Giulia; Felisatti, Giovanna; Lavezzi, Susanna; Zoppellari, Roberto; Gariboldi, Valentina; Lorini, Luca; Melizza, Giovanni; Molinero, Guido; Mandalà, Giorgio; Pignataro, Amedeo; Montis, Andrea; Napoleone, Alessandro; Pilia, Felicita; Pisu, Marina; Semerjian, Monica; Pagliaro, Giuseppina; Nardin, Lorella; Scarponi, Federico; Zampolini, Mauro; Zava, Raffaele; Massetti, Maria A; Piccolini, Carlo; Aloj, Fulvio; Antonelli, Sergio; Zucchella, Chiara
2016-02-01
The increased survival after a severe acquired brain injury (sABI) raise the problem of making most effective the treatments in Intensive Care Unit (ICU)/Neurointensive Care Unit (NICU), also integrating rehabilitation care. Despite previous studies reported that early mobilization in ICU was effective in preventing complications and reducing hospital stay, few studies addressed the rehabilitative management of sABI patients in ICU/NICU. To collect clinical and functional data about the early rehabilitative management of sABI patients during ICU/NICU stay. Prospective, observational, multicenter study. Fourteen facilities supplied by intensive neurorehabilitation units and ICU/NICUs. Consecutive sABI patients admitted to ICU/NICU. Patients were evaluated at admission and then every 3-5 days. Clinical, functional and rehabilitative data, including Glasgow Coma Scale (GCS), Disability Rating Scale (DRS), The Rancho Los Amigos Levels of Cognitive Functioning Scale (LCF), Early Rehabilitation Barthel Index (ERBI), Glasgow Outcome scale (GOS) and Functional Independence Measure (FIM) were collected. One hundred and two patients (F/M 44/58) were enrolled. The mean duration of ICU stay was 24.7±13.9 days and the first rehabilitative evaluation occurred after 8.7±8.8 days. Regular postural changes and multijoint mobilization were prescribed in 63.7% and 64.7% cases, respectively. The mean session duration was 38±11.5 minutes. Swallowing evaluation was performed in 14.7% patients, psychological support was provided to 12.7% of patients' caregivers, while 17.6% received a psycho-educational intervention, and 28.4% were involved in interdisciplinary team meetings. The main discharge destinations were Severe Acquired Brain Injury rehabilitation units for 43.7%, intensive neurorehabilitation units for 20.7%. Data showed that early rehabilitation was not diffusely performed in sABI subjects in ICU/NICU and rehabilitative interventions were variable; one-third of subjects were not referred to dedicated rehabilitation unit at discharge. The study stresses the need to spread and implement a rehabilitative culture also for critical ill patients due to neurological diseases.
DeVille, J Brian; Svinarich, J Thomas; Dan, Dan; Wickliffe, Andrew; Kantipudi, Charan; Lim, Hae W; Plummer, Lisa; Baker, James; Kowalski, Marcin; Baydoun, Hassan; Jenkins, Mark; Chang-Sing, Peter
2014-06-01
Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon with regard to hospital resource allocation. There was no statistical difference between cryoballoon and RF catheters for acute PVI success during the ablation procedure.
Gallium Arsenide Monolithic Optoelectronic Circuits
NASA Astrophysics Data System (ADS)
Bar-Chaim, N.; Katz, J.; Margalit, S.; Ury, I.; Wilt, D.; Yariv, A.
1981-07-01
The optical properties of GaAs make it a very useful material for the fabrication of optical emitters and detectors. GaAs also possesses electronic properties which allow the fabrication of high speed electronic devices which are superior to conventional silicon devices. Monolithic optoelectronic circuits are formed by the integration of optical and electronic devices on a single GaAs substrate. Integration of many devices is most easily accomplished on a semi-insulating (SI) sub-strate. Several laser structures have been fabricated on SI GaAs substrates. Some of these lasers have been integrated with Gunn diodes and with metal semiconductor field effect transistors (MESFETs). An integrated optical repeater has been demonstrated in which MESFETs are used for optical detection and electronic amplification, and a laser is used to regenerate the optical signal. Monolithic optoelectronic circuits have also been constructed on conducting substrates. A heterojunction bipolar transistor driver has been integrated with a laser on an n-type GaAs substrate.
NASA Technical Reports Server (NTRS)
Krainak, Michael; Merritt, Scott
2016-01-01
Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.
1993-02-10
new technology is to have sufficient control of processing to *- describable by an appropriate elecromagnetic model . build useful devices. For example...3. W aveguide Modulators .................................. 7 B. Integrated Optical Device and Circuit Modeling ... ................... .. 10 C...following categories: A. Integrated Optical Devices and Technology B. Integrated Optical Device and Circuit Modeling C. Cryogenic Etching for Low
Stakeholders' views on data sharing in multicenter studies.
Mazor, Kathleen M; Richards, Allison; Gallagher, Mia; Arterburn, David E; Raebel, Marsha A; Nowell, W Benjamin; Curtis, Jeffrey R; Paolino, Andrea R; Toh, Sengwee
2017-09-01
To understand stakeholders' views on data sharing in multicenter comparative effectiveness research studies and the value of privacy-protecting methods. Semistructured interviews with five US stakeholder groups. We completed 11 interviews, involving patients (n = 15), researchers (n = 10), Institutional Review Board and regulatory staff (n = 3), multicenter research governance experts (n = 2) and healthcare system leaders (n = 4). Perceptions of the benefits and value of research were the strongest influences toward data sharing; cost and security risks were primary influences against sharing. Privacy-protecting methods that share summary-level data were acknowledged as being appealing, but there were concerns about increased cost and potential loss of research validity. Stakeholders were open to data sharing in multicenter studies that offer value and minimize security risks.
Gantner, Pierre; Mélard, Adeline; Damond, Florence; Delaugerre, Constance; Dina, Julia; Gueudin, Marie; Maillard, Anne; Sauné, Karine; Rodallec, Audrey; Tuaillon, Edouard; Plantier, Jean-Christophe; Rouzioux, Christine; Avettand-Fenoel, Véronique
2017-11-01
Viral reservoirs represent an important barrier to HIV cure. Accurate markers of HIV reservoirs are needed to develop multicenter studies. The aim of this multicenter quality control (QC) was to evaluate the inter-laboratory reproducibility of total HIV-1-DNA quantification. Ten laboratories of the ANRS-AC11 working group participated by quantifying HIV-DNA with a real-time qPCR assay (Biocentric) in four samples (QCMD). Good reproducibility was found between laboratories (standard deviation ≤ 0.2 log 10 copies/10 6 PBMC) for the three positive QC that were correctly classified by each laboratory (QC1
Seiler, CM; Fröhlich, BE; Veit, JA; Gazyakan, E; Wente, MN; Wollermann, C; Deckert, A; Witte, S; Victor, N; Buchler, MW; Knaebel, HP
2006-01-01
Background Annually, more than 90000 surgical procedures of the thyroid gland are performed in Germany. Strategies aimed at reducing the duration of the surgical procedure are relevant to patients and the health care system especially in the context of reducing costs. However, new techniques for quick and safe hemostasis have to be tested in clinically relevance randomized controlled trials before a general recommendation can be given. The current standard for occlusion of blood vessels in thyroid surgery is ligatures. Vascular clips may be a safe alternative but have not been investigated in a large RCT. Methods/design CLIVIT (Clips versus Ligatures in Thyroid Surgery) is an investigator initiated, multicenter, patient-blinded, two-group parallel relevance randomized controlled trial designed by the Study Center of the German Surgical Society. Patients scheduled for elective resection of at least two third of the gland for benign thyroid disease are eligible for participation. After surgical exploration patients are randomized intraoperatively into either the conventional ligature group, or into the clip group. The primary objective is to test for a relevant reduction in operating time (at least 15 min) when using the clip technique. Since April 2004, 121 of the totally required 420 patients were randomized in five centers. Discussion As in all trials the different forms of bias have to be considered, and as in this case, a surgical trial, the role of surgical expertise plays a key role, and will be documented and analyzed separately. This is the first randomized controlled multicenter relevance trial to compare different vessel occlusion techniques in thyroid surgery with adequate power and other detailed information about the design as well as framework. If significant, the results might be generalized and may change the current surgical practice. PMID:16948853
Yang, James Chin-Hsin; Ahn, Myung-Ju; Nakagawa, Kazuhiko; Tamura, Tomohide; Barraclough, Helen; Enatsu, Sotaro; Cheng, Rebecca; Orlando, Mauro
2015-01-01
Purpose A recent phase III study (PARAMOUNT) demonstrated that pemetrexed continuation maintenance therapy is a new treatment paradigm for advanced nonsquamous non-small cell lung cancer (NSCLC). The majority of patients enrolled in PARAMOUNT were Caucasian (94%). We reviewed efficacy and safety data from two clinical trials, which enrolled East Asian (EA) patients, to supplement data from PARAMOUNT on pemetrexed continuation maintenance therapy in patients with nonsquamous NSCLC. Materials and Methods Study S110 was a phase II, multicenter, randomized, controlled, open-label trial in never-smoker, chemonaïve, EA patients (n=31) with locally advanced or metastatic nonsquamous NSCLC (n=27). Study JMII was a multicenter, open-label, single-arm, post-marketing, clinical trial in Japanese patients (n=109) with advanced nonsquamous NSCLC. PARAMOUNT was a multicenter, randomized, double-blind, placebo-controlled trial in patients with advanced nonsquamous NSCLC. Results In EA patients with nonsquamous NSCLC, the median progression-free survival (PFS) for pemetrexed continuation maintenance therapy was 4.04 months (95% confidence interval [CI], 3.22 to 5.29 months) in study S110 and 3.9 months (95% CI, 3.2 to 5.2 months) in study JMII. The median PFS for pemetrexed continuation maintenance therapy in PARAMOUNT was 4.1 months (95% CI, 3.2 to 4.6 months). Pemetrexed continuation maintenance therapy in EA patients in studies S110 and JMII did not lead to any unexpected safety events, and was consistent with PARAMOUNT’s safety profile. Conclusion The efficacy and safety data in the EA trials were similar to those in PARAMOUNT despite differences in patient populations and study designs. These data represent consistent evidence for pemetrexed continuation maintenance therapy in EA patients with advanced nonsquamous NSCLC. PMID:25410761
March, John S; Klee, Brian J; Kremer, Charlotte M E
2006-01-01
The aim of this study was to examine the balance between the benefits of treatment and the risk of suicidality in children and adolescents in multicenter, randomized, controlled trials of sertraline versus placebo. The published literature was searched for multicenter, randomized, placebo-controlled trials of sertraline for pediatric mental disorders. Four trials were identified: Two (pooled) in pediatric major depressive disorder (MDD; Wagner 2003) and two in obsessive-compulsive disorder (OCD; March et al. 1998; POTS Team 2004). Using intent-to-treat (ITT) analysis populations, the authors calculated the number needed to treat (NNT) for response and remission and the number needed to harm (NNH) for suicidality, and their ratio, for each clinical trial. NNTs ranged from 2 to 10, indicating clinically meaningful benefits. Benefit was greater for OCD than for MDD, and for adolescents as compared with children in MDD. No age effect was apparent for OCD. Suicidality was reported in 8 patients (5 assigned to sertraline and 3 assigned to placebo). All but 1 (a placebo-treated patient in the Pfizer OCD trial) were enrolled in the sertraline MDD trial. The NNH for suicidality in MDD was 64. Treatment emergent suicidality was more common in children (NNH 28.7) than in adolescents (NNH 706.3). Because no patient developed suicidality in sertraline-treated OCD patients, the NNH for sertraline in OCD approaches infinity. With the stipulation that doctor and patient preferences necessarily play a critical role in the choice of treatment, NNT to NNH ratios indicate a positive benefit-to-risk ratio for sertraline in adolescents with MDD and in patients of all ages with OCD.
Yang, James Chin-Hsin; Ahn, Myung-Ju; Nakagawa, Kazuhiko; Tamura, Tomohide; Barraclough, Helen; Enatsu, Sotaro; Cheng, Rebecca; Orlando, Mauro
2015-07-01
A recent phase III study (PARAMOUNT) demonstrated that pemetrexed continuation maintenance therapy is a new treatment paradigm for advanced nonsquamous non-small cell lung cancer (NSCLC). The majority of patients enrolled in PARAMOUNT were Caucasian (94%). We reviewed efficacy and safety data from two clinical trials, which enrolled East Asian (EA) patients, to supplement data from PARAMOUNT on pemetrexed continuation maintenance therapy in patients with nonsquamous NSCLC. Study S110 was a phase II, multicenter, randomized, controlled, open-label trial in never-smoker, chemonaïve, EA patients (n=31) with locally advanced or metastatic nonsquamous NSCLC (n=27). Study JMII was a multicenter, open-label, single-arm, post-marketing, clinical trial in Japanese patients (n=109) with advanced nonsquamous NSCLC. PARAMOUNT was a multicenter, randomized, double-blind, placebo-controlled trial in patients with advanced nonsquamous NSCLC. In EA patients with nonsquamous NSCLC, the median progression-free survival (PFS) for pemetrexed continuation maintenance therapy was 4.04 months (95% confidence interval [CI], 3.22 to 5.29 months) in study S110 and 3.9 months (95% CI, 3.2 to 5.2 months) in study JMII. The median PFS for pemetrexed continuation maintenance therapy in PARAMOUNT was 4.1 months (95% CI, 3.2 to 4.6 months). Pemetrexed continuation maintenance therapy in EA patients in studies S110 and JMII did not lead to any unexpected safety events, and was consistent with PARAMOUNT's safety profile. The efficacy and safety data in the EA trials were similar to those in PARAMOUNT despite differences in patient populations and study designs. These data represent consistent evidence for pemetrexed continuation maintenance therapy in EA patients with advanced nonsquamous NSCLC.
Quasi-four-particle first-order Faddeev-Watson-Lovelace terms in proton-helium scattering
NASA Astrophysics Data System (ADS)
Safarzade, Zohre; Akbarabadi, Farideh Shojaei; Fathi, Reza; Brunger, Michael J.; Bolorizadeh, Mohammad A.
2017-06-01
The Faddeev-Watson-Lovelace equations, which are typically used for solving three-particle scattering problems, are based on the assumption of target having one active electron while the other electrons remain passive during the collision process. So, in the case of protons scattering from helium or helium-like targets, in which there are two bound-state electrons, the passive electron has a static role in the collision channel to be studied. In this work, we intend to assign a dynamic role to all the target electrons, as they are physically active in the collision. By including an active role for the second electron in proton-helium-like collisions, a new form of the Faddeev-Watson-Lovelace integral equations is needed, in which there is no disconnected kernel. We consider the operators and the wave functions associated with the electrons to obey the Pauli exclusion principle, as the electrons are indistinguishable. In addition, a quasi-three-particle collision is assumed in the initial channel, where the electronic cloud is represented as a single identity in the collision.
Electron dynamics in a plasma focus. [electron acceleration
NASA Technical Reports Server (NTRS)
Hohl, F.; Gary, S. P.; Winters, P. A.
1977-01-01
Results are presented of a numerical integration of the three-dimensional relativistic equations of motion of electrons subject to given electric and magnetic fields deduced from experiments. Fields due to two different models are investigated. For the first model, the fields are those due to a circular distribution of axial current filaments. As the current filaments collapse toward the axis, large azimuthal magnetic and axial electric fields are induced. These fields effectively heat the electrons to a temperature of approximately 8 keV and accelerate electrons within the radius of the filaments to high axial velocities. Similar results are obtained for the current-reduction phase of focus formation. For the second model, the fields are those due to a uniform current distribution. Both the current-reduction and the compression phases were studied. These is little heating or acceleration of electrons during the compression phase because the electrons are tied to the magnetic field. However, during the current-reduction phase, electrons near the axis are accelerated toward the center electrode and reach energies of 100 keV. A criterion is obtained which limits the runaway electron current to about 400 A.
Low-background detector arrays for infrared astronomy
NASA Technical Reports Server (NTRS)
Mccreight, C. R.; Estrada, J. A.; Goebel, J. H.; Mckelvey, M. E.; Mckibbin, D. D.; Mcmurray, R. E., Jr.; Weber, T. T.
1989-01-01
The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.
2002-12-11
KENNEDY SPACE CENTER, FLA. -- KSC technicians supervise the offloading of the Integrated Equipment Assembly (IEA), one of two major components of the Starboard 6 (S6) truss segment for the International Space Station (ISS), onto a cargo transporter following its arrival at the Shuttle Landing Facility. The IEA will be joined to its companion piece, the Long Spacer, before launch early in 2004. The S6 truss segment will be the 11th and final piece of the Station's Integrated Truss Structure and will support the fourth and final set of solar arrays, batteries, and electronics.
2002-12-11
KENNEDY SPACE CENTER, FLA. -- KSC technicians supervise the transfer of the Integrated Equipment Assembly (IEA), one of two major components of the Starboard 6 (S6) truss segment for the International Space Station (ISS), onto a cargo transporter following its arrival at the Shuttle Landing Facility. The IEA will be joined to its companion piece, the Long Spacer, before launch early in 2004. The S6 truss segment will be the 11th and final piece of the Station's Integrated Truss Structure and will support the fourth and final set of solar arrays, batteries, and electronics.
Luyckx, Kim; Luyten, Léon; Daelemans, Walter; Van den Bulcke, Tim
2016-01-01
Objective Enormous amounts of healthcare data are becoming increasingly accessible through the large-scale adoption of electronic health records. In this work, structured and unstructured (textual) data are combined to assign clinical diagnostic and procedural codes (specifically ICD-9-CM) to patient stays. We investigate whether integrating these heterogeneous data types improves prediction strength compared to using the data types in isolation. Methods Two separate data integration approaches were evaluated. Early data integration combines features of several sources within a single model, and late data integration learns a separate model per data source and combines these predictions with a meta-learner. This is evaluated on data sources and clinical codes from a broad set of medical specialties. Results When compared with the best individual prediction source, late data integration leads to improvements in predictive power (eg, overall F-measure increased from 30.6% to 38.3% for International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnostic codes), while early data integration is less consistent. The predictive strength strongly differs between medical specialties, both for ICD-9-CM diagnostic and procedural codes. Discussion Structured data provides complementary information to unstructured data (and vice versa) for predicting ICD-9-CM codes. This can be captured most effectively by the proposed late data integration approach. Conclusions We demonstrated that models using multiple electronic health record data sources systematically outperform models using data sources in isolation in the task of predicting ICD-9-CM codes over a broad range of medical specialties. PMID:26316458
Tensor numerical methods in quantum chemistry: from Hartree-Fock to excitation energies.
Khoromskaia, Venera; Khoromskij, Boris N
2015-12-21
We resume the recent successes of the grid-based tensor numerical methods and discuss their prospects in real-space electronic structure calculations. These methods, based on the low-rank representation of the multidimensional functions and integral operators, first appeared as an accurate tensor calculus for the 3D Hartree potential using 1D complexity operations, and have evolved to entirely grid-based tensor-structured 3D Hartree-Fock eigenvalue solver. It benefits from tensor calculation of the core Hamiltonian and two-electron integrals (TEI) in O(n log n) complexity using the rank-structured approximation of basis functions, electron densities and convolution integral operators all represented on 3D n × n × n Cartesian grids. The algorithm for calculating TEI tensor in a form of the Cholesky decomposition is based on multiple factorizations using algebraic 1D "density fitting" scheme, which yield an almost irreducible number of product basis functions involved in the 3D convolution integrals, depending on a threshold ε > 0. The basis functions are not restricted to separable Gaussians, since the analytical integration is substituted by high-precision tensor-structured numerical quadratures. The tensor approaches to post-Hartree-Fock calculations for the MP2 energy correction and for the Bethe-Salpeter excitation energies, based on using low-rank factorizations and the reduced basis method, were recently introduced. Another direction is towards the tensor-based Hartree-Fock numerical scheme for finite lattices, where one of the numerical challenges is the summation of electrostatic potentials of a large number of nuclei. The 3D grid-based tensor method for calculation of a potential sum on a L × L × L lattice manifests the linear in L computational work, O(L), instead of the usual O(L(3) log L) scaling by the Ewald-type approaches.
Barbui, Corrado; Motterlini, Nicola; Garattini, Livio
2006-02-01
In this study we estimated the health status, resource consumption and costs of a large cohort of patients with early and late-onset dysthymia. The DYSCO (DYSthymia COsts) project is a multi-center observational study which prospectively followed for two years a randomly chosen sample of patients with dysthymia in the Italian primary health care system. A total of 501 patients were followed for two years; 81% had early-onset dysthymic disorder. During the study, improvement was seen in most domains of the 36-Item Short Form Health Survey (SF-36) questionnaire. Comparison of the SF-36 scores for the two groups showed that only the physical health index significantly differed during the two years. The use of outpatient consultations, laboratory tests and diagnostic procedures was similar in the two groups, but patients with early-onset dysthymia were admitted significantly more than late-onset cases. Hospital admissions were almost entirely responsible for the higher total cost per patient per year of early-onset dysthymia. A first limitation of this study is that general practitioners were selected on the basis of their willingness to participate, not at random; secondly, no information was collected on concomitant psychiatric comorbidities. The present study provides the first prospective, long-term data on service use and costs in patients with dysthymia. Differently from patients with early-onset dysthymia, patients with late-onset dysthymia were admitted less and cost less.
Transport coefficients in nonequilibrium gas-mixture flows with electronic excitation.
Kustova, E V; Puzyreva, L A
2009-10-01
In the present paper, a one-temperature model of transport properties in chemically nonequilibrium neutral gas-mixture flows with electronic excitation is developed. The closed set of governing equations for the macroscopic parameters taking into account electronic degrees of freedom of both molecules and atoms is derived using the generalized Chapman-Enskog method. The transport algorithms for the calculation of the thermal-conductivity, diffusion, and viscosity coefficients are proposed. The developed theoretical model is applied for the calculation of the transport coefficients in the electronically excited N/N(2) mixture. The specific heats and transport coefficients are calculated in the temperature range 50-50,000 K. Two sets of data for the collision integrals are applied for the calculations. An important contribution of the excited electronic states to the heat transfer is shown. The Prandtl number of atomic species is found to be substantially nonconstant.
Asherson, P; Stes, S; Nilsson Markhed, M; Berggren, L; Svanborg, P; Kutzelnigg, A; Deberdt, W
2015-06-01
To investigate the effects of atomoxetine on emotional control in adults with ADHD. We performed an integrated analysis using individual patient data pooled from three Eli Lilly-sponsored studies. An integrated analysis can be viewed as a meta-analysis of individual patient-level data, rather than study-level summary data. Two populations were identified: a large sample of patients with pre-treatment baseline data (the "overall population"; n=2846); and a subset of these patients with placebo-controlled efficacy data from baseline to 10 or 12 weeks after initiating treatment (the "placebo-controlled population"; n=829). At baseline, in the overall population, ∼50% of ADHD patients had BRIEF-AS (Behavior Rating Inventory of Executive Function-Adult Version Self-Report) Emotional control subscores between 21 and 30, compared with ∼10% of normative subjects in the BRIEF-A manual. At endpoint, in the placebo-controlled population, atomoxetine led to a small (effect size 0.19) but significant (P=0.013) treatment effect for emotional control. The effect size was 0.32 in patients with BRIEF-AS Emotional control scores>20 at baseline. Improvements in emotional control correlated with improvements in the core ADHD symptoms and quality-of-life. As deficient emotional control is associated with impaired social, educational and occupational functioning over and above that explained by core ADHD symptoms alone, improvements in emotional control may be clinically relevant. At baseline, adults with ADHD were more likely to have impaired emotional control than normative subjects. In the adult ADHD patients, atomoxetine treatment was associated with improvements in emotional control, as well as in core ADHD symptoms and quality-of-life. Copyright © 2015. Published by Elsevier Masson SAS.
... A recent prospective multicenter trial called STASCIS is exploring whether performing decompression surgery early (less than 24 ... A recent prospective multicenter trial called STASCIS is exploring whether performing decompression surgery early (less than 24 ...
Gigahertz flexible graphene transistors for microwave integrated circuits.
Yeh, Chao-Hui; Lain, Yi-Wei; Chiu, Yu-Chiao; Liao, Chen-Hung; Moyano, David Ricardo; Hsu, Shawn S H; Chiu, Po-Wen
2014-08-26
Flexible integrated circuits with complex functionalities are the missing link for the active development of wearable electronic devices. Here, we report a scalable approach to fabricate self-aligned graphene microwave transistors for the implementation of flexible low-noise amplifiers and frequency mixers, two fundamental building blocks of a wireless communication receiver. A devised AlOx T-gate structure is used to achieve an appreciable increase of device transconductance and a commensurate reduction of the associated parasitic resistance, thus yielding a remarkable extrinsic cutoff frequency of 32 GHz and a maximum oscillation frequency of 20 GHz; in both cases the operation frequency is an order of magnitude higher than previously reported. The two frequencies work at 22 and 13 GHz even when subjected to a strain of 2.5%. The gigahertz microwave integrated circuits demonstrated here pave the way for applications which require high flexibility and radio frequency operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tarisien, M.; Plaisir, C.; Gobet, F.
2011-02-15
We present a stand-alone system to characterize the high-energy particles emitted in the interaction of ultrahigh intensity laser pulses with matter. According to the laser and target characteristics, electrons or protons are produced with energies higher than a few mega electron volts. Selected material samples can, therefore, be activated via nuclear reactions. A multidetector, named NATALIE, has been developed to count the {beta}{sup +} activity of these irradiated samples. The coincidence technique used, designed in an integrated system, results in very low background in the data, which is required for low activity measurements. It, therefore, allows a good precision onmore » the nuclear activation yields of the produced radionuclides. The system allows high counting rates and online correction of the dead time. It also provides, online, a quick control of the experiment. Geant4 simulations are used at different steps of the data analysis to deduce, from the measured activities, the energy and angular distributions of the laser-induced particle beams. Two applications are presented to illustrate the characterization of electrons and protons.« less
Facilitating secondary use of medical data by using openEHR archetypes.
Kohl, Christian D; Garde, Sebastian; Knaup, Petra
2010-01-01
Clinical trials are of high importance for medical progress. But even though more and more clinical data is available in electronic patient records (EPRs) and more and more electronic data capture (EDC) systems are used in trials, there is still a gap which makes EPR / EDC interoperability difficult and hampers secondary use of medical routine data. The openEHR architecture for Electronic Health Records is based on a two level modeling approach which makes use of 'archetypes'. We want to analyze whether archetypes can help to bridge this gap by building an integrated EPR / EDC system based on openEHR archetypes. We used the 'openEHR Reference Framework and Application' (Opereffa) and existing archetypes for medical data. Furthermore, we developed dedicated archetypes to document study meta data. We developed a first prototype implementation of an archetype based integrated EPR / EDC system. Next steps will be the evaluation of an extended prototype in a real clinical trial scenario. Opereffa was a good starting point for our work. OpenEHR archetypes proved useful for secondary use of health data.
Hlaing, Htay; Kim, Chang-Hyun; Carta, Fabio; Nam, Chang-Yong; Barton, Rob A; Petrone, Nicholas; Hone, James; Kymissis, Ioannis
2015-01-14
The vertical integration of graphene with inorganic semiconductors, oxide semiconductors, and newly emerging layered materials has recently been demonstrated as a promising route toward novel electronic and optoelectronic devices. Here, we report organic thin film transistors based on vertical heterojunctions of graphene and organic semiconductors. In these thin heterostructure devices, current modulation is accomplished by tuning of the injection barriers at the semiconductor/graphene interface with the application of a gate voltage. N-channel devices fabricated with a thin layer of C60 show a room temperature on/off ratio >10(4) and current density of up to 44 mAcm(-2). Because of the ultrashort channel intrinsic to the vertical structure, the device is fully operational at a driving voltage of 200 mV. A complementary p-channel device is also investigated, and a logic inverter based on two complementary transistors is demonstrated. The vertical integration of graphene with organic semiconductors via simple, scalable, and low-temperature fabrication processes opens up new opportunities to realize flexible, transparent organic electronic, and optoelectronic devices.
Scaled plane-wave Born cross sections for atoms and molecules
NASA Astrophysics Data System (ADS)
Tanaka, H.; Brunger, M. J.; Campbell, L.; Kato, H.; Hoshino, M.; Rau, A. R. P.
2016-04-01
Integral cross sections for optically allowed electronic-state excitations of atoms and molecules by electron impact, by applying scaled plane-wave Born models, are reviewed. Over 40 years ago, Inokuti presented an influential review of charged-particle scattering, based on the theory pioneered by Bethe forty years earlier, which emphasized the importance of reliable cross-section data from low eV energies to high keV energies that are needed in many areas of radiation science with applications to astronomy, plasmas, and medicine. Yet, with a couple of possible exceptions, most computational methods in electron-atom scattering do not, in general, overlap each other's validity range in the region from threshold up to 300 eV and, in particular, in the intermediate region from 30 to 300 eV. This is even more so for electron-molecule scattering. In fact this entire energy range is of great importance and, to bridge the gap between the two regions of low and high energy, scaled plane-wave Born models were developed to provide reliable, comprehensive, and absolute integral cross sections, first for ionization by Kim and Rudd and then extended to optically allowed electronic-state excitation by Kim. These and other scaling models in a broad, general application to electron scattering from atoms and molecules, their theoretical basis, and their results for cross sections along with comparison to experimental measurements are reviewed. Where possible, these data are also compared to results from other computational approaches.
Bajwa, Sukhminder Jit Singh
2014-01-01
Over the years, traditional anaesthesia record keeping system has been the backbone of anaesthesiology ever since its introduction in the 1890s by Dr. Harvey Cushing and Dr. Ernest A. Codman. Besides providing the important information regarding patients’ vital physiologic parameters, paper records had been a reliable source for various clinical research activities. The introduction of electronic monitoring gadgets and electronic record keeping systems has revolutionised the anaesthesiology practice to a large extent. Recently, the introduction of anaesthesia information management system (AIMS), which incorporates all the features of monitoring gadgets, such as electronic storage of large accurate data, quality assurance in anaesthesia, enhancing patient safety, ensuring legal protection, improved billing services and effecting an organisational change, is almost a revolution in modern-day anaesthesiology practice. The clinical research activities that are responsible for taking anaesthesiology discipline to higher peaks have also been boosted by the amalgamation of AIMS, enabling multicenter studies and sharing of clinical data. Barring few concerns in its installation, cost factors and functional aspects, the future of AIMS seems to be bright and will definitely prove to be a boon for modern-day anaesthesiology practice. PMID:24963173
Two-bunch operation with ns temporal separation at the FERMI FEL facility
NASA Astrophysics Data System (ADS)
Penco, Giuseppe; Allaria, Enrico; Bassanese, Silvano; Cinquegrana, Paolo; Cleva, Stefano; Danailov, Miltcho B.; Demidovich, Alexander; Ferianis, Mario; Gaio, Giulio; Giannessi, Luca; Masciovecchio, Claudio; Predonzani, Mauro; Rossi, Fabio; Roussel, Eleonore; Spampinati, Simone; Trovò, Mauro
2018-05-01
In the last decade, a continuous effort has been dedicated to extending the capabilities of existing free-electron lasers (FELs) operating in the x-ray and vacuum ultraviolet regimes. In this framework, the generation of two-color (or multi-color) temporally separated FEL pulses, has paved the way to new x-ray pump and probe experiments and several two-color two-pulse schemes have been implemented at the main facilities, but with a generally limited time-separation between the pulses, from 0 to few hundreds of fs. This limitation may be overcome by generating light with two independent electron bunches, temporally separated by integral multiples of the radio-frequency period. This solution was investigated at FERMI, measurements and characterization of this two-bunch mode of operation are presented, including trajectory control, impact of longitudinal and transverse wakefields, manipulation of the longitudinal phase space and finally a demonstration of suitability of the scheme to provide extreme ultraviolet light by using both bunches.
NASA Astrophysics Data System (ADS)
McLeod, A. F.; Gritschneder, M.; Dale, J. E.; Ginsburg, A.; Klaassen, P. D.; Mottram, J. C.; Preibisch, T.; Ramsay, S.; Reiter, M.; Testi, L.
2016-11-01
We present an analysis of the effect of feedback from O- and B-type stars with data from the integral field spectrograph Multi Unit Spectroscopic Explorer (MUSE) mounted on the Very Large Telescope of pillar-like structures in the Carina Nebular Complex, one of the most massive star-forming regions in the Galaxy. For the observed pillars, we compute gas electron densities and temperatures maps, produce integrated line and velocity maps of the ionized gas, study the ionization fronts at the pillar tips, analyse the properties of the single regions, and detect two ionized jets originating from two distinct pillar tips. For each pillar tip, we determine the incident ionizing photon flux Q0, pil originating from the nearby massive O- and B-type stars and compute the mass-loss rate dot{M} of the pillar tips due to photoevaporation caused by the incident ionizing radiation. We combine the results of the Carina data set with archival MUSE data of a pillar in NGC 3603 and with previously published MUSE data of the Pillars of Creation in M16, and with a total of 10 analysed pillars, find tight correlations between the ionizing photon flux and the electron density, the electron density and the distance from the ionizing sources, and the ionizing photon flux and the mass-loss rate. The combined MUSE data sets of pillars in regions with different physical conditions and stellar content therefore yield an empirical quantification of the feedback effects of ionizing radiation. In agreement with models, we find that dot{M}∝ Q_0,pil^{1/2}.
Cher, Daniel Joseph; Reckling, W Carlton
2015-01-01
Pain from the sacroiliac joint (SIJ) is an under-recognized cause of low back pain. The degree to which SIJ pain decreases quality of life has not been directly compared to other more familiar conditions of the lumbar spine. Multivariate regression analysis of individual patient data from two prospective multicenter clinical trials of SIJ fusion and three prospective multicenter clinical trials of surgical treatments for degenerative lumbar spine conditions. Controlling for baseline demographic parameters as well as a validated disability score, quality of life scores (EuroQOL 5-D and SF-36) were, in most cases, lower in the SIJ cohorts compared to the three other spine surgery cohorts. Patients with SIJ dysfunction considering surgery have decrements in quality of life as or more severe compared to patients with degenerative spondylolisthesis, spinal stenosis, and intervertebral disc herniation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bena, Iosif; Bobev, Nikolay; Warner, Nicholas P.
We discuss 'spectral-flow' coordinate transformations that take asymptotically four-dimensional solutions into other asymptotically four-dimensional solutions. We find that spectral flow can relate smooth three-charge solutions with a multicenter Taub-NUT base to solutions where one or several Taub-NUT centers are replaced by two-charge supertubes, and vice versa. We further show that multiparameter spectral flows can map such Taub-NUT centers to more singular centers that are either D2-D0 or pure D0-brane sources. Since supertubes can depend on arbitrary functions, we establish that the moduli space of smooth horizonless black-hole microstate solutions is classically of infinite dimension. We also use the physics ofmore » supertubes to argue that some multicenter solutions that appear to be bound states from a four-dimensional perspective are in fact not bound states when considered from a five- or six-dimensional perspective.« less
Emerging indications of endoscopic radiofrequency ablation
Becq, Aymeric; Camus, Marine; Rahmi, Gabriel; de Parades, Vincent; Marteau, Philippe
2015-01-01
Introduction Radiofrequency ablation (RFA) is a well-validated treatment of dysplastic Barrett's esophagus. Other indications of endoscopic RFA are under evaluation. Results Four prospective studies (total 69 patients) have shown that RFA achieved complete remission of early esophageal squamous intra-epithelial neoplasia at a rate of 80%, but with a substantial risk of stricture. In the setting of gastric antral vascular ectasia, two prospective monocenter studies, and a retrospective multicenter study, (total 51 patients), suggest that RFA is efficacious in terms of reducing transfusion dependency. In the setting of chronic hemorrhagic radiation proctopathy, a prospective monocenter study and a retrospective multicenter study (total 56 patients) suggest that RFA is an efficient treatment. A retrospective comparative study (64 patients) suggests that RFA improves stents patency in malignant biliary strictures. Conclusions Endoscopic RFA is an upcoming treatment modality in early esophageal squamous intra-epithelial neoplasia, as well as in gastric, rectal, and biliary diseases. PMID:26279839
Bennett, R M
1986-01-01
Diflunisal, a nonacetylated salicylate preparation with a prolonged duration of action, was compared with ibuprofen for the treatment of rheumatoid arthritis in a multicenter trial comprising 210 patients. Diflunisal was administered twice a day (500 to 750 mg/day) and ibuprofen was administered four times a day (1,600 to 2,400 mg/day). To maintain double-blind conditions, all patients ostensibly followed the same regimen, ingesting their assigned drug and a matching placebo of their nonassigned drug. Disease activity assessments and laboratory tests were done periodically throughout the 12 weeks of the study, and results were compared with pretreatment findings. Efficacy evaluations in 187 patients showed that both treatments were similarly efficacious. Safety and tolerability also were similar in the two groups. Diflunisal, however, offers a more acceptable BID treatment schedule.
Cheung, Stephanie; Hoi, Sannifer; Fernandes, Olavo; Huh, Jin; Kynicos, Sara; Murphy, Laura; Lowe, Donna
2018-04-01
Dangerous abbreviations on the Institute for Safe Medication Practices Canada's "Do Not Use" list have resulted in medication errors leading to harm. Data comparing rates of use of dangerous abbreviations in paper and electronic medication orders are limited. To compare rates of use of dangerous abbreviations from the "Do Not Use" list, in paper and electronic medication orders. Secondary objectives include determining the proportion of patients at risk for medication errors due to dangerous abbreviations and the most commonly used dangerous abbreviations. One-day cross-sectional audits of medication orders were conducted at a 6-site hospital network in Toronto, Canada, between December 2013 and January 2014. Proportions of paper and electronic medication orders containing dangerous abbreviation(s) were compared using a χ 2 test. The proportion of patients with at least 1 medication order containing dangerous abbreviation(s) and the top 5 dangerous abbreviations used were described. Overall, 255 patient charts were reviewed. The proportions of paper and electronic medication orders containing dangerous abbreviation(s) were 172/714 (24.1%) and 9/2207 (0.4%), respectively ( P < 0.001). Almost one-third of patients had medication order(s) containing dangerous abbreviation(s). The proportions of patients with at least 1 medication order during the audit period containing dangerous abbreviation(s) for patients with paper only, electronic only, or a hybrid of paper and electronic medication orders were 50.5%, 5%, and 47.2%, respectively. Those most commonly used were "D/C", drug name abbreviations, "OD," "cc," and "U." Electronic medication orders have significantly lower rates of dangerous abbreviation use compared to paper medication orders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Dongfan, E-mail: fangdongfan1208@126.com; Sun, Qizhi; Zhao, Xiaoming
A 633 nm laser interferometer has been designed based on a novel concept, which, without the acousto-optic modulator or the demodulator circuit, adopts the fibers to connect all elements except photodetectors and oscilloscope in this system to make it more compact, portable, and efficient. The noteworthy feature is to mathematically compare the two divided interference signals, which have the same phase-shift caused by the electron density but possess the different initial phase and low angular frequencies. It is possible to read the plasma density directly on the oscilloscope by our original mathematic demodulation method without a camera. Based on themore » Abel inversion algorithm, the radial electron density profiles versus time can be obtained by using the multi-chord system. The designed measurable phase shift ranges from 0 to 2π rad corresponding to the maximum line integral of electron density less than 3.5 × 10{sup 17} cm{sup −2}, and the phase accuracy is about 0.017 rad corresponding to the line integral of electron density accuracy of 1 × 10{sup 15} cm{sup −2}. After the construction of eight-chord interferometer, it will provide the detailed time resolved information of the spatial distribution of the electron density in the field-reversed configuration (FRC) plasma target produced by the “Yingguang-1” programmed-discharge device, which is being constructed in the Key Laboratory of Pulsed Power, China Academy of Engineering Physics.« less
Method for integrating microelectromechanical devices with electronic circuitry
Montague, S.; Smith, J.H.; Sniegowski, J.J.; McWhorter, P.J.
1998-08-25
A method is disclosed for integrating one or more microelectromechanical (MEM) devices with electronic circuitry. The method comprises the steps of forming each MEM device within a cavity below a device surface of the substrate; encapsulating the MEM device prior to forming electronic circuitry on the substrate; and releasing the MEM device for operation after fabrication of the electronic circuitry. Planarization of the encapsulated MEM device prior to formation of the electronic circuitry allows the use of standard processing steps for fabrication of the electronic circuitry. 13 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Jingsong; Sumpter, Bobby G; Meunier, Vincent
2011-01-01
Phenalenyl and its derivatives have recently attracted a great deal of interest as a result of a 2-electron multicenter (2e/mc) covalent pi-pi bonding between two pi-stacked phenalenyl units. The 2e/mc bonded pi-dimers are close in energy to the sigma-dimers of phenalenyl and therefore fickle properties may emerge from bond fluctuation, yielding smart pi-functional materials. Here we examine the valence tautomerization of two cyclo-biphenalenyl biradicaloid molecular materials with chair- and boat-conformations by spin-restricted (R) and unrestricted (U) DFT using the M06 and B3LYP functionals. We found that the chair-conformation involves a 2e/4c pi-pi bonded structure while the boat-conformation involves a 2e/12cmore » pi-pi bonded structure on their potential energy surfaces. The global minimum for the chair-conformation is the sigma-bonded structure while it is the pi-pi bonded structure for the boat-conformation. The chair-conformation exhibits a stepwise [3,3]-sigmatropic rearrangement, and calculations predict a negligible paramagnetic susceptibility near room temperature. In comparison, the paramagnetism of the boat-conformation should be observable by SQUID and/or ESR. According to the difference of the global minima of the two conformations and the parameterized UV-Vis calculations, the color of the chair-conformation is expected to become darker while that of the boat-conformation become lighter with increasing temperature.« less
A new approach for two-terminal electronic memory devices - Storing information on silicon nanowires
NASA Astrophysics Data System (ADS)
Saranti, Konstantina; Alotaibi, Sultan; Paul, Shashi
2016-06-01
The work described in this paper focuses on the utilisation of silicon nanowires as the information storage element in flash-type memory devices. Silicon nanostructures have attracted attention due to interesting electrical and optical properties, and their potential integration into electronic devices. A detailed investigation of the suitability of silicon nanowires as the charge storage medium in two-terminal non-volatile memory devices are presented in this report. The deposition of the silicon nanostructures was carried out at low temperatures (less than 400 °C) using a previously developed a novel method within our research group. Two-terminal non-volatile (2TNV) memory devices and metal-insulator-semiconductor (MIS) structures containing the silicon nanowires were fabricated and an in-depth study of their characteristics was carried out using current-voltage and capacitance techniques.