Sample records for type electrical connector

  1. Spline screw payload fastening system

    NASA Technical Reports Server (NTRS)

    Vranish, John M. (Inventor)

    1993-01-01

    A system for coupling an orbital replacement unit (ORU) to a space station structure via the actions of a robot and/or astronaut is described. This system provides mechanical and electrical connections both between the ORU and the space station structure and between the ORU and the ORU and the robot/astronaut hand tool. Alignment and timing features ensure safe, sure handling and precision coupling. This includes a first female type spline connector selectively located on the space station structure, a male type spline connector positioned on the orbital replacement unit so as to mate with and connect to the first female type spline connector, and a second female type spline connector located on the orbital replacement unit. A compliant drive rod interconnects the second female type spline connector and the male type spline connector. A robotic special end effector is used for mating with and driving the second female type spline connector. Also included are alignment tabs exteriorally located on the orbital replacement unit for berthing with the space station structure. The first and second female type spline connectors each include a threaded bolt member having a captured nut member located thereon which can translate up and down the bolt but are constrained from rotation thereabout, the nut member having a mounting surface with at least one first type electrical connector located on the mounting surface for translating with the nut member. At least one complementary second type electrical connector on the orbital replacement unit mates with at least one first type electrical connector on the mounting surface of the nut member. When the driver on the robotic end effector mates with the second female type spline connector and rotates, the male type spline connector and the first female type spline connector lock together, the driver and the second female type spline connector lock together, and the nut members translate up the threaded bolt members carrying the first type electrical connector up to the complementary second type connector for interconnection therewith.

  2. Usability testing and requirements derivation for EMU-compatible electrical connectors

    NASA Technical Reports Server (NTRS)

    Reaux, Ray A.; Griffin, Thomas J.; Lewis, Ruthan

    1989-01-01

    On-orbit servicing of payloads is simplified when a spacecraft has been designed for serviceability. A key design criterion for a serviceable spaceraft is standardization of electrical connectors. This paper investigates the effects of extravehicular mobility unit (EMU) glove size, connector size, and connector type on usability of electrical connectors. An experiment was conducted exploring participants' ability to mate and demate connectors in an evacuated glovebox. Independent variables were two EMU glove-sizes, five connector size groups, and seven connector types. Significant differences in performance times and heart rate changes during mate and demate operations were found. Subjective assessments of connectors were collected from participants with a usability questionnaire. The data were used to derive design recommendations for a NASA-recommended EMU-compatible electrical connector.

  3. Cables and connectors: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    A technological compilation on devices and techniques for various types of electrical cables and connections is presented. Data are reported under three sections: flat conductor cable technology, newly developed electrical connectors, and miscellaneous articles and information on cables and connector techniques.

  4. CABLE CONNECTOR

    DOEpatents

    Caller, J.M.

    1962-05-01

    An electrical connector is designed for utilization in connection with either round or flat coaxial cables. The connector comprises a bayonet-type coupling arrangement with a splined movable locking sleeve adapted to lock together components of the connector. A compression spring is attached to one of the connector components and functions to forcibly separate mating components when the locking sleeve is in an unlocked condition so as to minimize the possibility of leaving the conductors electrically coupled. (AEC)

  5. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  6. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  7. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  8. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  9. 30 CFR 18.41 - Plug and receptacle-type connectors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...

  10. Evolution of low-profile and lightweight electrical connectors for soldier-worn applications

    NASA Astrophysics Data System (ADS)

    Gans, Eric; Lee, Kang; Jannson, Tomasz; Walter, Kevin

    2011-06-01

    In addition to military radios, modern warfighters carry cell phones, GPS devices, computers, and night-vision aids, all of which require electrical cables and connectors for data and power transmission. Currently each electrical device operates via independent cables using conventional cable and connector technology. Conventional cables are stiff and difficult to integrate into a soldier-worn garment. Conventional connectors are tall and heavy, as they were designed to ensure secure connections to bulkhead-type panels, and being tall, represent significant snag-hazards in soldier-worn applications. Physical Optics Corporation has designed a new, lightweight and low-profile electrical connector that is more suitable for body-worn applications and operates much like a standard garment snap. When these connectors are mated, the combined height is <0.3 in. - a significant reduction from the 2.5 in. average height of conventional connectors. Electrical connections can be made with one hand (gloved or bare) and blindly (without looking). Furthermore, POC's connectors are integrated into systems that distribute data or power from a central location on the soldier's vest, reducing the length and weight of the cables necessary to interconnect various mission-critical electronic systems. The result is a lightweight power/data distribution system offering significant advantages over conventional electrical connectors in soldier-worn applications.

  11. Residential Wiring: Electrical Connections [and] Tools and Equipment.

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    Intended for student use, this unit focuses on making good electrical splices and electrical connections, and discusses tools and equipment used in house wiring jobs. Specific areas covered in the connections section are types of splices, solder equipment and supplies, and solderless connectors (plastic caps, split bolt connectors, crimp-type…

  12. Space and Missile Systems Center Standard: Technical Requirements for Electronic Parts, Materials, and Processes used in Space Vehicles

    DTIC Science & Technology

    2013-04-12

    DTL-38999 Connector, Electrical, Circular, Miniature, High Density, Quick Disconnect (Bayonet, Threaded , and Breach Coupling), Environment Resistant ...186 Table 1160-1. Resistance Tolerance and Required Derating...For MIL-DTL-5015 Connector, Electrical, Circular Threaded , AN Type, General Specification for MIL-H-6088G(1) Heat Treatment of Aluminum Alloys

  13. High pressure electrical insulated feed thru connector

    DOEpatents

    Oeschger, Joseph E.; Berkeland, James E.

    1979-11-13

    A feed-thru type hermetic electrical connector including at least one connector pin feeding through an insulator block within the metallic body of the connector shell. A compression stop arrangement coaxially disposed about the insulator body is brazed to the shell, and the shoulder on the insulator block bears against this top in a compression mode, the high pressure or internal connector being at the opposite end of the shell. Seals between the pin and an internal bore at the high pressure end of the insulator block and between the insulator block and the metallic shell at the high pressure end are hermetically brazed in place, the first of these also functioning to transfer the axial compressive load without permitting appreciable shear action between the pin and insulator block.

  14. QUICK DISCONNECT ELECTRICAL CONNECTOR

    DOEpatents

    None

    1962-08-14

    A remotely actuated quick-dlsconnect electrical connector which comprises a pair of mating portrons releasably retained together by a bayonet- type joint with a rotatable sleeve on one of the mating portions providing for engagement and disengagement of the joint is described. A lanyard with ends passed through fulcrums and affixed to the sleeve erfects rotation of the sleeve and disengages the joint. (AEC)

  15. High-density percutaneous chronic connector for neural prosthetics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, Kedar G.; Bennett, William J.; Pannu, Satinderpall S.

    2015-09-22

    A high density percutaneous chronic connector, having first and second connector structures each having an array of magnets surrounding a mounting cavity. A first electrical feedthrough array is seated in the mounting cavity of the first connector structure and a second electrical feedthrough array is seated in the mounting cavity of the second connector structure, with a feedthrough interconnect matrix positioned between a top side of the first electrical feedthrough array and a bottom side of the second electrical feedthrough array to electrically connect the first electrical feedthrough array to the second electrical feedthrough array. The two arrays of magnetsmore » are arranged to attract in a first angular position which connects the first and second connector structures together and electrically connects the percutaneously connected device to the external electronics, and to repel in a second angular position to facilitate removal of the second connector structure from the first connector structure.« less

  16. An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Dahlgren, Scott; Fox, Joe; Sneddon, Cameron; Briscoe, Michael

    2005-11-29

    A coaxial cable electrical connector more specifically an internal coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transfonner. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive care of the coaxial cable. A plurality of bulbous pliant tabs on the coaxial cable connector mechanically engage the inside diameter of the coaxial cable thus grounding the transformer to the coaxial cable. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string.

  17. Inline Electrical Connector Mate/Demate Pliers

    NASA Technical Reports Server (NTRS)

    Yutko, Brian; Dininny, Michael; Moscoso, Gerand; Dokos, Adam

    2010-01-01

    Military and aerospace industries use Mil-Spec type electrical connections on bulkhead panels that require inline access for mate and demate operations. These connectors are usually in tight proximity to other connectors, or recessed within panels. The pliers described here have been designed to work in such tight spaces, and consist of a mirrored set of parallel handles, two cross links, two return springs, and replaceable polyurethane-coated end effectors. The polyurethane eliminates metal-to-metal contact and provides a high-friction surface between the jaw and the connector. Operationally, the user would slide the pliers over the connector shell until the molded polyurethane lip makes contact with the connector shell edge. Then, by squeezing the handles, the end effector jaws grip the connector shell, allowing the connector to be easily disconnected by rotating the pliers. Mating the connector occurs by reversing the prescribed procedure, except the connector shell is placed into the jaws by hand. The molded lip within the jaw allows the user to apply additional force for difficult-to-mate connectors. Handle design has been carefully examined to maximize comfort, limit weight, incorporate tether locations, and improve ergonomics. They have been designed with an off-axis offset for wiring harness clearance, while placing the connector axis of rotation close to the user s axis of wrist rotation. This was done to eliminate fatigue during multiple connector panel servicing. To limit handle opening width, with user ergonomics in mind, the pliers were designed using a parallel jaw mechanism. A cross-link mechanism was used to complete this task, while ensuring smooth operation.

  18. An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Dahlgren, Scott; Fox, Joe; Sneddon, Cameron; Briscoe, Michael

    2005-09-20

    A seal for a coaxial cable electrical connector more specifically an internal seal for a coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transformer. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive core of the coaxial cable. The electrically insulating material also doubles as a seal to safegaurd against penetration of fluid, thus protecting against shorting out of the electrical connection. The seal is a multi-component seal, which is pre-compressed to a desired pressure rating. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string. The internal coaxial cable connector and its attendant seal can be used in a plurality of downhole tools, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

  19. Electrical connector composite housing and method of making same

    DOEpatents

    Silva, Frank A.

    1979-01-01

    A sleeve-like insert of conductive elastomeric material of a type which serves as an internal shield in electrical connectors for connecting high voltage cables has an end portion folded upon itself, the enfolded portion being substantially permanently retained in its desired position by allowing insulative elastomeric material to fill apertures in the end portion and become bonded thereto in a void free manner, during molding of an insulating outer sleeve-like jacket about the insert.

  20. Interrogation of electrical connector faults using miniaturized UWB sources

    NASA Astrophysics Data System (ADS)

    Tokgöz, Çaǧata; Dardona, Sameh

    2017-01-01

    A diagnostic method for the detection, identification, and characterization of precursors of faults due to partial insertion of pin-socket contacts within electrical connectors commonly used in avionics systems is presented. It is demonstrated that a miniaturized ultrawideband (UWB) source and a minispectrum analyzer can be employed to measure resonant frequency shifts in connector S parameters as a small and low-cost alternative to a large and expensive network analyzer. The transfer function of an electrical connector is represented as a ratio of the spectra measured using the spectrum analyzer with and without the connector. Alternatively, the transfer function is derived in terms of the connector S parameters and the reflection coefficients at both ports of the connector. The transfer function data obtained using this derivation agreed well with its representation as a measured spectral ratio. The derivation enabled the extraction of the connector S parameters from the measured transfer function data as a function of the insertion depth of a pin-socket contact within the connector. In comparison with the S parameters measured directly using a network analyzer at multiple insertion depths, the S parameters extracted from the measured transfer function showed consistent and reliable representation of the electrical connector fault. The results demonstrate the potential of integrating a low-cost miniaturized UWB device into a connector harness for real-time detection of precursors to partially inserted connector faults.

  1. The effect of illumination and electrode adjustment on the carrier behavior in special multilayer devices

    NASA Astrophysics Data System (ADS)

    Deng, Yanhong; Ou, Qingdong; Wang, Jinjiang; Zhang, Dengyu; Chen, Liezun; Li, Yanqing

    2017-08-01

    Intermediate connectors play an important role in semiconductor devices, especially in tandem devices. In this paper, four types of different intermediate connectors (e.g. Mg:Alq3/MoO3, MoO3, Mg:Alq3, and none) and two kinds of modified electrode materials (LiF and MoO3) integrated into the special multilayer devices are proposed, with the aim of studying the impact of light illumination and electrode adjustment on the carrier behavior of intermediate connectors through the current density-voltage characteristics, interfacial electronic structures, and capacitance-voltage characteristics. The results show that the illumination enhances the charge generation and separation in intermediate connectors, and further electrode interface modifications enhance the functionality of intermediate connectors. In addition, the device with an efficient intermediate connector structure shows a photoelectric effect, which paves the way for organic photovoltaic devices to realize optical-electrical integration transformation.

  2. Electronic firing systems and methods for firing a device

    DOEpatents

    Frickey, Steven J [Boise, ID; Svoboda, John M [Idaho Falls, ID

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  3. Flexible connector

    DOEpatents

    Savage, Mark E.; Simpson, Walter W.

    1999-01-01

    An electrical connector accommodates high current, is not labor intensive to assemble and disassemble, and allows a wide range of motion to accommodate mechanical variations and movement of connected components. The connector comprises several parts with joints therebetween, wherein each joint provides electrical connection between and allows relative motion of the joined parts. The combination of parts and joints maintains electrical connection between two electrical components even if the components are misaligned or move after connection.

  4. Electrical stator

    DOEpatents

    Fanning, Alan W.; Olich, Eugene E.

    1994-01-01

    An electrical stator of an electromagnetic pump includes first and second spaced apart coils each having input and output terminals for carrying electrical current. An elongate electrical connector extends between the first and second coils and has first and second opposite ends. The connector ends include respective slots receiving therein respective ones of the coil terminals to define respective first and second joints. Each of the joints includes a braze filler fixedly joining the connector ends to the respective coil terminals for carrying electrical current therethrough.

  5. Flexible connector

    DOEpatents

    Savage, M.E.; Simpson, W.W.

    1999-07-27

    An electrical connector accommodates high current, is not labor intensive to assemble and disassemble, and allows a wide range of motion to accommodate mechanical variations and movement of connected components. The connector comprises several parts with joints therebetween, wherein each joint provides electrical connection between and allows relative motion of the joined parts. The combination of parts and joints maintains electrical connection between two electrical components even if the components are misaligned or move after connection. 6 figs.

  6. Integrated electrical connector

    DOEpatents

    Benett, William J.; Ackler, Harold D.

    2005-05-24

    An electrical connector is formed from a sheet of electrically conductive material that lies in between the two layers of nonconducting material that comprise the casing of an electrical chip. The connector is electrically connected to an electrical element embedded within the chip. An opening in the sheet is concentrically aligned with a pair of larger holes respectively bored through the nonconducting layers. The opening is also smaller than the diameter of an electrically conductive contact pin. However, the sheet is composed flexible material so that the opening adapts to the diameter of the pin when the pin is inserted therethrough. The periphery of the opening applies force to the sides of the pin when the pin is inserted, and thus holds the pin within the opening and in contact with the sheet, by friction. The pin can be withdrawn from the connector by applying sufficient axial force.

  7. Spacecraft Electrical Connector Selection and Application Processes

    NASA Technical Reports Server (NTRS)

    Iannello, Chris; Davis, Mitchell I; Kichak, Robert A.; Slenski, George

    2009-01-01

    This assessment was initiated by the NASA Engineering & Safety Center (NESC) after a number of recent "high profile" connector problems, the most visible and publicized of these being the problem with the Space Shuttle's Engine Cut-Off System cryogenic feed-thru connector. The NESC commissioned a review of NASA's connector selection and application processes for space flight applications, including how lessons learned and past problem records are fed back into the processes to avoid recurring issues. Team members were primarily from the various NASA Centers and included connector and electrical parts specialists. The commissioned study was conducted on spacecraft connector selection and application processes at NASA Centers. The team also compared the NASA spacecraft connector selection and application process to the military process, identified recent high profile connector failures, and analyzed problem report data looking for trends and common occurrences. The team characterized NASA's connector problem experience into a list of top connector issues based on anecdotal evidence of a system's impact and commonality between Centers. These top issues are as follows, in no particular rank order: electrically shorted, bent and/or recessed contact pins, contact pin/socket contamination leading to electrically open or intermittencies, connector plating corrosion or corrosion of connector components, low or inadequate contact pin retention forces, contact crimp failures, unmated connectors and mis-wiring due to workmanship errors during installation or maintenance, loose connectors due to manufacturing defects such as wavy washer and worn bayonet retention, damaged connector elastomeric seals and cryogenic connector failure. A survey was also conducted of SAE Connector AE-8C1 committee members regarding their experience relative to the NASA concerns on connectors. The most common responses in order of occurrence were contact retention, plating issues, worn-out or damaged coupling mechanisms, bent pins, contact crimp barrel cracking and torn seals. In addition to these common themes, responses included issues with markings, dimensional errors on the build, contact/socket damage (handling), manufacturing defects and customer misapplication and mishandling. The NESC team concluded that considering the large quantity and wide variety of connectors successfully flown on human and robotic space applications, the number of failures is quite low. However, "high profile" failures with significant cost, schedule, safety, and/or mission success impacts continue to occur. It was also concluded that connector failures occur throughout a system's life-cycle with the majority of connector issues application related. A number of recommendations were identified for improving NASA connector selection processes and overall space connector reliability and performance.

  8. Analytical study of electrical disconnect system for use on manned and unmanned missions

    NASA Technical Reports Server (NTRS)

    Rosener, A. A.; Lenda, J. A.; Trummer, R. O.; Jonkoniec, T. G.

    1977-01-01

    The program to survey existing electrical connector availability, and establish an optimum connector design for maintainable spacecraft substation interfaces is reported. Functional and operational requirements are given along with the results of the documentation survey, which disclosed that the MSFC series connectors have the preferred features of current connector technology. Optimum design concepts for EVA tasks, modules serviced by manipulators, and for manipulators independent of other servicing units are presented. It is concluded that separate connector designs are required for spacecraft replaceable modules, and for crewman EVA.

  9. Modeling and characterization of partially inserted electrical connector faults

    NASA Astrophysics Data System (ADS)

    Tokgöz, ćaǧatay; Dardona, Sameh; Soldner, Nicholas C.; Wheeler, Kevin R.

    2016-03-01

    Faults within electrical connectors are prominent in avionics systems due to improper installation, corrosion, aging, and strained harnesses. These faults usually start off as undetectable with existing inspection techniques and increase in magnitude during the component lifetime. Detection and modeling of these faults are significantly more challenging than hard failures such as open and short circuits. Hence, enabling the capability to locate and characterize the precursors of these faults is critical for timely preventive maintenance and mitigation well before hard failures occur. In this paper, an electrical connector model based on a two-level nonlinear least squares approach is proposed. The connector is first characterized as a transmission line, broken into key components such as the pin, socket, and connector halves. Then, the fact that the resonance frequencies of the connector shift as insertion depth changes from a fully inserted to a barely touching contact is exploited. The model precisely captures these shifts by varying only two length parameters. It is demonstrated that the model accurately characterizes a partially inserted connector.

  10. MPO-type single-mode multi-fiber connector: Low-loss and high-return-loss intermateability of APC-MPO connectors

    NASA Astrophysics Data System (ADS)

    Satake, Toshiaki; Nagasawa, Shinji; Hughes, Mike; Lutz, Sharon

    2011-01-01

    The electrical communication laboratory of NTT started the research of MT (Mechanically Transferable) connector in early 1980s. The initial goal was to realize a multi-fiber connector which can repeat low loss, stable, reliable and low-cost connections of subscriber optical fiber cable networks for more than 20 years period in the field. We review the multi-fiber alignment design with two guide pins, and following several technical improvements toward the final MT connector used in the commercial telecommunication networks. And then, we review development histories to reach to the low-loss, high-return-loss and reliable APC-MPO (Angled Physical Contact Multi-fiber Push On) connectors introduced in NTT COs and in Verizon's FTTH (Fiber To The Home) networks. In the latter half, we propose the low-loss intermateability design for connectors made by different suppliers in order to enable mass introductions into large scale systems. In addition we also describe an accurate connector loss presumption method for different lots' ferrules based on the MT ferrule dimension data before assembling the connectors. We believe with a wide intermateability of APC-MPO connector will increase its use in the fields. The APC-MPO connector manufactured based on the proposed design had low insertion losses of less than 0.25 dB at the same level of simplex connectors and the higher level of return losses higher than 65 dB.

  11. Comparison of Models of Stress Relaxation in Failure Analysis for Connectors under Long-term Storage

    NASA Astrophysics Data System (ADS)

    Zhou, Yilin; Wan, Mengru

    2018-03-01

    Reliability requirements of the system equipment under long-term storage are put forward especially for the military products, so that the connectors in the equipment also need long-term storage life correspondingly. In this paper, the effects of stress relaxation of the elastic components on electrical contact of the connectors in long-term storage process were studied from the failure mechanism and degradation models. A wire spring connector was taken as an example to discuss the life prediction method for electrical contacts of the connectors based on stress relaxation degradation under long -term storage.

  12. Cables and connectors for Large Space System Technology (LSST)

    NASA Technical Reports Server (NTRS)

    Dunbar, W. G.

    1980-01-01

    The effect of the environment and extravehicular activity/remote assembly operations on the cables and connectors for spacecraft with metallic and/or nonmetallic structures was examined. Cable and connector philosophy was outlined for the electrical systems and electronic compartments which contain high-voltage, high-power electrical and electronic equipment. The influence of plasma and particulates on the system is analyzed and the effect of static buildup on the spacecraft electrical system discussed. Conceptual cable and connector designs are assessed for capability to withstand high current and high voltage without danger of arcs and electromagnetic interference. The extravehicular activites required of the space station and/or supply spacecraft crew members to join and inspect the electrical system, using manual or remote assembly construction are also considered.

  13. Device serves as hinge and electrical connector for circuit boards

    NASA Technical Reports Server (NTRS)

    Bethel, P. G.; Harris, G. G.

    1966-01-01

    Hinge makes both sides of electrical circuit boards readily accessible for component checkout and servicing. The hinge permits mounting of two circuit boards and incorporates connectors to maintain continuous electrical contact between the components on both boards.

  14. Electrical connector

    DOEpatents

    Dilliner, Jennifer L.; Baker, Thomas M.; Akasam, Sivaprasad; Hoff, Brian D.

    2006-11-21

    An electrical connector includes a female component having one or more receptacles, a first test receptacle, and a second test receptacle. The electrical connector also includes a male component having one or more terminals configured to engage the one or more receptacles, a first test pin configured to engage the first test receptacle, and a second test pin configured to engage the second test receptacle. The first test receptacle is electrically connected to the second test receptacle, and at least one of the first test pin and the second test pin is shorter in length than the one or more terminals.

  15. Indexing device ensures proper mating of electrical connectors

    NASA Technical Reports Server (NTRS)

    Jenkins, L. M.; Simmons, W. H.

    1965-01-01

    Indexing splines with modified standard male and female connectors eliminates the possibility of incorrect mating. Large stock quantities of differently indexed connectors are unnecessary since connectors from a single stock can be indexed as desired at installation time.

  16. Easily disassembled electrical connector for high voltage, high frequency connections

    DOEpatents

    Milner, Joseph R.

    1994-01-01

    An easily accessible electrical connector capable of rapid assembly and disassembly wherein a wide metal conductor sheet may be evenly contacted over the entire width of the conductor sheet by opposing surfaces on the connector which provide an even clamping pressure against opposite surfaces of the metal conductor sheet using a single threaded actuating screw.

  17. Tool for Torquing Circular Electrical-Connector Collars

    NASA Technical Reports Server (NTRS)

    Gaulke, Kathryn; Werneth, Russell; Grunsfeld, John; O'Neill, Patrick; Snyder, Russ

    2006-01-01

    An improved tool has been devised for applying torque to lock and unlock knurled collars on circular electrical connectors. The tool was originally designed for, and used by, astronauts working in outer space on the Hubble Space Telescope (HST). The tool is readily adaptable to terrestrial use in installing and removing the same or similar circular electrical connectors as well as a wide variety of other cylindrical objects, the tightening and loosening of which entail considerable amounts of torque.

  18. Chronic, percutaneous connector for electrical recording and stimulation with microelectrode arrays.

    PubMed

    Shah, Kedar G; Lee, Kye Young; Tolosa, Vanessa; Tooker, Angela; Felix, Sarah; Benett, William; Pannu, Satinderpall

    2014-01-01

    The translation of advances in neural stimulation and recording research into clinical practice hinges on the ability to perform chronic experiments in awake and behaving animal models. Advances in microelectrode array technology, most notably flexible polymer arrays, have significantly improved reliability of the neural interface. However, electrical connector technology has lagged and is prone to failure from non-biocompatibility, large size, contamination, corrosion, and difficulty of use. We present a novel chronic, percutaneous electrical connector system that is suitable for neural stimulation and recording. This system features biocompatible materials, low connect and disconnect forces, passive alignment, and a protective cap during non-use. We have successfully designed, assembled, and tested in vitro both a 16-channel system and a high density 64-channel system. Custom, polyimide, 16-channel, microelectrode arrays were electrically assembled with the connector system and tested using cyclic voltammetry and electrochemical impedance spectroscopy. This connector system is versatile and can be used with a variety of microelectrode array technologies for chronic studies.

  19. Downhole transmission system comprising a coaxial capacitor

    DOEpatents

    Hall, David R [Provo, UT; Pixton, David S [Lehi, UT; Johnson, Monte L [Orem, UT; Bartholomew, David B [Springville, UT; Hall, Jr., H. Tracy; Rawle, Michael [Springville, UT

    2011-05-24

    A transmission system in a downhole component comprises a plurality of data transmission elements. A coaxial cable having an inner conductor and an outer conductor is disposed within a passage in the downhole component such that at least one capacitor is disposed in the passage and having a first terminal coupled to the inner conductor and a second terminal coupled to the outer conductor. Preferably the transmission element comprises an electrically conducting coil. Preferably, within the passage a connector is adapted to electrically connect the inner conductor of the coaxial cable and the lead wire. The coaxial capacitor may be disposed between and in electrically communication with the connector and the passage. In another embodiment a connector is adapted to electrical connect a first and a second portion of the inner conductor of the coaxial cable and a coaxial capacitor is in electrical communication with the connector and the passage.

  20. Easily disassembled electrical connector for high voltage, high frequency connections

    DOEpatents

    Milner, J.R.

    1994-05-10

    An easily accessible electrical connector capable of rapid assembly and disassembly is described wherein a wide metal conductor sheet may be evenly contacted over the entire width of the conductor sheet by opposing surfaces on the connector which provide an even clamping pressure against opposite surfaces of the metal conductor sheet using a single threaded actuating screw. 13 figures.

  1. High density electrical card connector system

    DOEpatents

    Haggard, J. Eric; Trotter, Garrett R.

    2000-01-01

    An electrical circuit board card connection system is disclosed which comprises a wedge-operated locking mechanism disposed along an edge portion of the printed circuit board. An extrusion along the edge of the circuit board mates with an extrusion fixed to the card cage having a plurality of electrical connectors. The connection system allows the connectors to be held away from the circuit board during insertion/extraction and provides a constant mating force once the circuit board is positioned and the wedge inserted. The disclosed connection system is a simple solution to the need for a greater number of electrical signal connections.

  2. 49 CFR 173.189 - Batteries containing sodium or cells containing sodium.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... providing complete electrical insulation of battery terminals or other external electrical connectors. Battery terminals or other electrical connectors penetrating the heat insulation fitted in battery casings must be provided with thermal insulation sufficient to prevent the temperature of the exposed surfaces...

  3. 49 CFR 173.189 - Batteries containing sodium or cells containing sodium.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., such as by providing complete electrical insulation of battery terminals or other external electrical connectors. Battery terminals or other electrical connectors penetrating the heat insulation fitted in battery casings must be provided with thermal insulation sufficient to prevent the temperature of the...

  4. 49 CFR 173.189 - Batteries containing sodium or cells containing sodium.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., such as by providing complete electrical insulation of battery terminals or other external electrical connectors. Battery terminals or other electrical connectors penetrating the heat insulation fitted in battery casings must be provided with thermal insulation sufficient to prevent the temperature of the...

  5. 49 CFR 173.189 - Batteries containing sodium or cells containing sodium.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... providing complete electrical insulation of battery terminals or other external electrical connectors. Battery terminals or other electrical connectors penetrating the heat insulation fitted in battery casings must be provided with thermal insulation sufficient to prevent the temperature of the exposed surfaces...

  6. Dust-Tolerant Intelligent Electrical Connection System

    NASA Technical Reports Server (NTRS)

    Lewis, Mark; Dokos, Adam; Perotti, Jose; Calle, Carlos; Mueller, Robert; Bastin, Gary; Carlson, Jeffrey; Townsend, Ivan, III; Immer, Chirstopher; Medelius, Pedro

    2012-01-01

    Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.

  7. Data Base On Cables And Connectors

    NASA Technical Reports Server (NTRS)

    Bowen, Arlen R.; Oliver, John D.

    1995-01-01

    Report describes Connector Adapter Cable Information Data Base (CONNAID) computer program, managing data base containing necessary information concerning electrical connectors, breakout boxes, adapter cables, backshells, and pertinent torque specifications for engineering project.

  8. Data port security lock

    DOEpatents

    Quinby, Joseph D [Albuquerque, NM; Hall, Clarence S [Albuquerque, NM

    2008-06-24

    In a security apparatus for securing an electrical connector, a plug may be fitted for insertion into a connector receptacle compliant with a connector standard. The plug has at least one aperture adapted to engage at least one latch in the connector receptacle. An engagement member is adapted to partially extend through at least one aperture and lock to at least one structure within the connector receptacle.

  9. System and method for sub-sea cable termination

    DOEpatents

    Chen, Qin; Yin, Weijun; Zhang, Lili

    2016-04-05

    An electrical connector includes a first cable termination chamber configured to receive a first power cable having at least a first conductor sheathed at least in part by a first insulating layer and a first insulation screen layer. Also, the electrical connector includes a first non-linear resistive layer configured to be coupled to a portion of the first conductor unsheathed by at least the first insulation screen layer and configured to control a direct current electric field generated in the first cable termination chamber. In addition, the electrical connector includes a first deflector configured to be coupled to the first power cable and control an alternating current electric field generated in the first cable termination chamber.

  10. Development of hermetic electrical connectors for SSC spool pieces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kountanis, B.; Kalny, L.

    1993-05-01

    The Superconducting Super Collider ring is about 54 miles (87 km circumference) and primarily includes a series of magnets. Spool piece assemblies are interspaced in the ring at predetermined intervals to provide specific functions such as cryogenic interfaces, vacuum interface, magnet power, magnet power dump, quench heater power, and special instrumentation. Electrical connectors serve as interfaces for instrumentation and quench heater circuits. These connectors have to meet stringent requirements.

  11. Connector and electronic circuit assembly for improved wet insulation resistance

    DOEpatents

    Reese, Jason A.; Teli, Samar R.; Keenihan, James R.; Langmaid, Joseph A.; Maak, Kevin D.; Mills, Michael E.; Plum, Timothy C.; Ramesh, Narayan

    2016-07-19

    The present invention is premised upon a connector and electronic circuit assembly (130) at least partially encased in a polymeric frame (200). The assembly including at least: a connector housing (230); at least one electrical connector (330); at least one electronic circuit component (430); and at least one barrier element (530).

  12. 75 FR 60010 - Airworthiness Directives; Airbus Model A330-200 and -300 Series Airplanes and Model A340-200...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-29

    ... hydraulic pump electrical motor connector internal arcing, resulting in: --Either false hydraulic system... uncontrolled fire. In order to protect the hydraulic pump electrical motor connectors against fluid ingress... hydraulic pump electrical motor malfunction, this AD requires modification of the three hydraulic pump...

  13. 76 FR 10230 - Airworthiness Directives; Airbus Model A330-200 and -300 Series Airplanes and Model A340-200...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... hydraulic pump electrical motor connector internal arcing, resulting in: --Either false hydraulic system... uncontrolled fire. In order to protect the hydraulic pump electrical motor connectors against fluid ingress... hydraulic pump electrical motor malfunction, this AD requires modification of the three hydraulic pump...

  14. Intelligent electrical harness connector assembly using Bell Helicopter Textron's 'Wire Harness Automated Manufacturing System'

    NASA Astrophysics Data System (ADS)

    Springer, D. W.

    Bell Helicopter Textron, Incorporated (BHTI) installed two Digital Equipment Corporation PDP-11 computers and an American Can Inc. Ink Jet printer in 1980 as the cornerstone of the Wire Harness Automated Manufacturing System (WHAMS). WHAMS is based upon the electrical assembly philosophy of continuous filament harness forming. This installation provided BHTI with a 3 to 1 return-on-investment by reducing wire and cable identification cycle time by 80 percent and harness forming, on dedicated layout tooling, by 40 percent. Yet, this improvement in harness forming created a bottle neck in connector assembly. To remove this bottle neck, BHTI has installed a prototype connector assembly cell that integrates the WHAMS' data base and innovative computer technologies to cut harness connector assembly cycle time. This novel connector assembly cell uses voice recognition, laser identification, and animated computer graphics to help the electrician in the correct assembly of harness connectors.

  15. Electrical interconnect

    DOEpatents

    Frost, John S.; Brandt, Randolph J.; Hebert, Peter; Al Taher, Omar

    2015-10-06

    An interconnect includes a first set of connector pads, a second set of connector pads, and a continuous central portion. A first plurality of legs extends at a first angle from the continuous central portion. Each leg of the first plurality of legs is connected to a connector pad of a first set of connector pads. A second plurality of legs extends at a second angle from the continuous central portion. Each leg of the second plurality of legs is connected to a connector pad of the second set of connector pads. Gaps are defined between legs. The gaps enable movement of the first set of connector pads relative to the second set of connector pads.

  16. Lightweight coaxial cable connector reduces signal loss

    NASA Technical Reports Server (NTRS)

    Brejcha, A. G., Jr.

    1965-01-01

    Connectors with milled interface surfaces for perfect electrical contact eliminate secondary- emission discharge and low signal loss in RF coaxial cables. the connectors which contain alignment and centering components for proper joint concentricity are used in communications systems designs.

  17. Electromagnetic interference filter for automotive electrical systems

    DOEpatents

    Herron, Nicholas Hayden; Carlson, Douglas S; Tang, David; Korich, Mark D

    2013-07-02

    A filter for an automotive electrical system includes a substrate having first and second conductive members. First and second input terminals are mounted to the substrate. The first input terminal is electrically connected to the first conductive member, and the second input terminal is electrically connected to the second conductive member. A plurality of capacitors are mounted to the substrate. Each of the capacitors is electrically connected to at least one of the first and second conductive members. First and second power connectors are mounted to the substrate. The first power connector is electrically connected to the first conductive member, and the second power connector is electrically connected to the second conductive member. A common mode choke is coupled to the substrate and arranged such that the common mode choke extends around at least a portion of the substrate and the first and second conductive members.

  18. Nuclear qualified in-containment electrical connectors and method of connecting electrical conductors

    DOEpatents

    Powell, J. G.

    1991-01-01

    A nuclear qualified in-containment electrical connection comprises an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires, a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom, two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable, a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position, a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom and heat shrunk thereon and a length of outer heat shrinkable plastic tubing extending over the end portion of the instrument lead and the heat shrinkable tubing thereon and over the butt splice connectors and a portion of the cable adjacent the cable lead lines, the outer heat shrinkable tubing being heat shrunk into sealing position on the instrument lead and cable.

  19. Analysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure.

    PubMed

    Kim, Sang-Hyo; Kim, Kun-Soo; Lee, Do-Hoon; Park, Jun-Seung; Han, Oneil

    2017-11-22

    Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of building structures. Thus, this paper proposes stubby Y-type perfobond rib shear connectors, redefining the existing connectors, for composite frames of building structures; these were used to perform push-out tests. These shear connectors have relatively small ribs compared to the conventional Y-type perfobond rib shear connectors. To confirm the shear resistance of these stubby shear connectors, we performed an experiment by using transverse rebars D13 and D16. The results indicate that these shear connectors have suitable shear strength and ductility for application in composite frame structures. The shear strengths obtained using D13 and D16 were not significantly different. However, the ductility of the shear connectors with D16 was 45.1% higher than that of the shear connectors with D13.

  20. Preload-Release Mechanism For Mounting Electronics Boxes

    NASA Technical Reports Server (NTRS)

    Generoli, Robert M.; Young, Harry J.

    1995-01-01

    Proposed mechanism applies spring preload to electrical connector only while needed during insertion of electronics box into supporting frame. Once connector fully mated, mechanism relieves preload. As result, supporting structure sized to handle only individual load applied briefly by each connector on box during insertion.

  1. Structural health monitoring of compression connectors for overhead transmission lines

    NASA Astrophysics Data System (ADS)

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P.; Ren, Fei; Chan, John

    2017-04-01

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over electrical conducting aluminum strands. The connectors are designed to operate at temperatures up to 125°C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements, but these methods do not provide information about the structural integrity of connectors. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Lead zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to induce structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.

  2. Connector Mechanism Has Smaller Stroke

    NASA Technical Reports Server (NTRS)

    Milam, M. Bruce

    1992-01-01

    System for connecting electrical and/or fluid lines includes mechanism reducing length of stroke necessary to make or break connections. Feature enables connection and disconnection in confined space, and compensates for misalignment between connectors. Connector in active member moves upward at twice the speed of downward stroke of passive member. Stroke amplified within connector system. Applications include connections between modular electronic units, coupled vehicles, and hydraulic systems.

  3. Flammability control for electrical cables and connectors

    NASA Technical Reports Server (NTRS)

    Wick, W. O.; Buckey, D. L.

    1973-01-01

    Technique of covering fire-hazardous sections of electrical wiring with fireproof materials prevents fires from spreading in oxygen-enriched atmospheres and eliminates use of heavy metal enclosures. Materials used to cover potting on connectors and ground terminals are made from Teflon-coated Beta cloth and Fluorel, a nonflammable fully-saturated polymer.

  4. A simple, efficient resistance soldering apparatus

    NASA Technical Reports Server (NTRS)

    Vermillion, C. M.

    1972-01-01

    Multiple resistance soldering device for attaching electric leads to multiple terminal block connectors uses power source with one terminal connected to working probe, and other terminal attached to connector carrying common pins for lead insertion. Mating of male and female connectors solders each lead to individual cup pin.

  5. 76 FR 31462 - Airworthiness Directives; The Boeing Company Model DC-10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... determine if a certain fuel pump housing electrical connector is installed. The existing AD also requires a... procedures for disabling certain fuel pump electrical circuits following failure of a fuel pump housing electrical connector if applicable. The existing AD also requires the deactivation of certain fuel tanks or...

  6. Method for hermetic electrical connections

    DOEpatents

    Monroe, Saundra L [Tijeras, NM; Glass, S Jill [Albuquerque, NM; Stone, Ronnie G [Albuquerque, NM; Bond, Jamey T [Albuquerque, NM; Susan, Donald F [Albuquerque, NM

    2011-12-27

    A method of providing a hermetic, electrical connection between two electrical components by mating at least one metal pin in a glass-ceramic to metal seal connector to two electrical components, wherein the glass-ceramic to metal seal connector incorporates at least one metal pin encased (sealed) in a glass-ceramic material inside of a metal housing, with the glass-ceramic material made from 65-80% SiO.sub.2, 8-16% Li.sub.2O, 2-8% Al.sub.2O.sub.3, 1-5% P.sub.2O.sub.5, 1-8% K.sub.2O, 0.5-7% B.sub.2O.sub.3, and 0-5% ZnO. The connector retains hermeticity at temperatures as high as 700.degree. C. and pressures as high as 500 psi.

  7. 21 CFR 870.2900 - Patient transducer and electrode cable (including connector).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Patient transducer and electrode cable (including... § 870.2900 Patient transducer and electrode cable (including connector). (a) Identification. A patient transducer and electrode cable (including connector) is an electrical conductor used to transmit signals from...

  8. 21 CFR 870.2900 - Patient transducer and electrode cable (including connector).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Patient transducer and electrode cable (including... § 870.2900 Patient transducer and electrode cable (including connector). (a) Identification. A patient transducer and electrode cable (including connector) is an electrical conductor used to transmit signals from...

  9. 21 CFR 870.2900 - Patient transducer and electrode cable (including connector).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Patient transducer and electrode cable (including... § 870.2900 Patient transducer and electrode cable (including connector). (a) Identification. A patient transducer and electrode cable (including connector) is an electrical conductor used to transmit signals from...

  10. Reliable Wiring Harness

    NASA Technical Reports Server (NTRS)

    Gaspar, Kenneth C.

    1987-01-01

    New harness for electrical wiring includes plugs that do not loosen from vibration. Ground braids prevented from detaching from connectors and constrained so braids do not open into swollen "birdcage" sections. Spring of stainless steel encircles ground braid. Self-locking connector contains ratchet not only preventing connector from opening, but tightens when vibrated.

  11. Shrink-Fit Solderable Inserts Seal Hermetically

    NASA Technical Reports Server (NTRS)

    Croucher, William C.

    1992-01-01

    Shrink-fit stainless-steel insert in aluminum equipment housing allows electrical connectors to be replaced by soldering, without degrading hermeticity of housing or connector. Welding could destroy electrostatic-sensitive components and harm housing and internal cables. Steel insert avoids problems because connector soldered directly to it rather than welded to housing. Seals between flange and housing, and between connector and flange resistant to leaks, even after mechanical overloading and thermal shocking.

  12. Electrical Connector Mechanical Seating Sensor

    NASA Technical Reports Server (NTRS)

    Arens, Ellen; Captain, Janine; Youngquist, Robert

    2011-01-01

    A sensor provides a measurement of the degree of seating of an electrical connector. This sensor provides a number of discrete distances that a plug is inserted into a socket or receptacle. The number of measurements is equal to the number of pins available in the connector for sensing. On at least two occasions, the Shuttle Program has suffered serious time delays and incurred excessive costs simply because a plug was not seated well within a receptacle. Two methods were designed to address this problem: (1) the resistive pin technique and (2) the discrete length pins technique. In the resistive pin approach, a standard pin in a male connector is replaced with a pin that has a uniform resistivity along its length. This provides a variable resistance on that pin that is dependent on how far the pin is inserted into a socket. This is essentially a linear potentiometer. The discrete approach uses a pin (or a few pins) in the connector as a displacement indicator by truncating the pin length so it sits shorter in the connector than the other pins. A loss of signal on this pin would indicate a discrete amount of displacement of the connector. This approach would only give discrete values of connector displacement, and at least one pin would be needed for each displacement value that would be of interest.

  13. Apparatus for adapting an end effector device remotely controlled manipulator arm

    NASA Technical Reports Server (NTRS)

    Clark, K. H. (Inventor)

    1985-01-01

    Apparatus for adapting a general purpose and effector device to a special purpose and effector is disclosed which includes an adapter bracket assembly which provides a mechanical and electrical interface between the end effector devices. The adapter bracket assembly includes an adapter connector post which interlocks with a diamond shaped gripping channel formed in closed jaws of the general purpose end effector. The angularly intersecting surfaces of the connector post and gripping channel prevent any relative movement there between. Containment webs constrain the outer finger plates of the general purpose jaws to prevent pitch motion. Electrical interface is provided by conical, self aligning electrical connector components carried by respective ones of said end effectors.

  14. Nuclear qualified in-containment electrical connectors and methods of connecting electrical conductors

    NASA Astrophysics Data System (ADS)

    Powell, J. G.

    1990-07-01

    A nuclear qualified in-containment electrical connection is presented that comprises: (1) an insulated, sheathed instrument lead having electrical conductors extending from one end thereof to provide two exposed lead wires; (2) a watertight cable having electrical conducting wires therein and extending from one end of the cable to provide two lead wires therefrom; (3) two butt splice connectors each connecting the ends of respective ones of the lead wires from the instrument lead and cable; (4) a length of heat shrinkable plastic tubing positioned over each butt splice connector and an adjacent portion of a respective lead wire from the cable and heat shrunk into position; and (5) a length of heat shrinkable plastic tubing on the end portion of the instrument lead adjacent the lead wires therefrom, heat shrunk thereon, with a length of outer heat shrinkable plastic tubing. The plastic tubing extends over the end portion of the instrument lead and the heat shrinkable tubing and over the butt splice connectors and a portion of the cable adjacent the cable lead lines. The outer heat shrinkable tubing is heat shrunk into sealing position on the instrument lead and cable.

  15. Photovoltaic module kit including connector assembly for non-penetrating array installation

    DOEpatents

    Botkin, Jonathan; Graves, Simon; Danning, Matt; Culligan, Matthew

    2013-12-31

    A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assempbled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting regions of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized slidably receive the male fastener, with all of the connector heads being identical.

  16. Photovoltaic module kit including connector assembly for non-penetrating array installation

    DOEpatents

    Botkin, Jonathan [El Cerrito, CA; Graves, Simon [Berkeley, CA; Danning, Matt [Oakland, CA; Culligan, Matthew [Berkeley, CA

    2011-11-22

    A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assembled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting region of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized to slidably receive the male fastener, with all of the connector heads being identical.

  17. Photovoltaic module kit including connector assembly for non-penetrating array installation

    DOEpatents

    Botkin, Jonathan; Graves, Simon; Danning, Matt; Culligan, Matthew

    2012-10-23

    A PV module kit for non-penetrating rooftop installation, including a plurality of PV modules and a plurality of connectors. Each of the PV modules includes a PV laminate and a frame forming a mounting region assembled thereto. The connectors include a male connector having a male fastener extending from a head, and a female connector having a female fastener assembled within a head. The heads are entirely formed of plastic. The kit provides a mounted array state including a junction at which the mounting region of at least two of the PV modules are aligned and interconnected by engagement of the male connector with the female connector. The so-formed junction is substantially electrically insulated. The plurality of connectors can further include a spacer connector including a head forming a bore sized to slidably receive the male fastener, with all of the connector heads being identical.

  18. Right-Angle Mechanized Electrical Connector

    NASA Technical Reports Server (NTRS)

    Collins, Clint A.; Blackler, David T.

    1996-01-01

    Right-angle electrical connector embedded in mechanism accommodates some initial misalignment and aligns itself. Connection and disconnection effected with relatively small forces and torques and simple movements. Actuated by one gloved hand or by robotic manipulator. Useful in underwater, nuclear, hot, cold, or toxic environments in which connections made or broken by heavily clothed technicians or by robots.

  19. 77 FR 6520 - Airworthiness Directives; BAE SYSTEMS (OPERATIONS) LIMITED Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... baggage bay fire bottles that can be misassembled such that two squib electrical connectors can be cross... fire in one of the baggage bays, could result in the fire extinguishing agent being discharged into a... 146 and AVRO 146-RJ aeroplanes can be misassembled such that two squib electrical connectors can be...

  20. Zone heated diesel particulate filter electrical connection

    DOEpatents

    Gonze, Eugene V.; Paratore, Jr., Michael J.

    2010-03-30

    An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

  1. CONNECTOR

    DOEpatents

    Stevens, D.J.

    1962-01-23

    A multiple-contact electrical connector is designed for facilitating correct alignment of the contacts of a movable component with the contacts in a normally stationary component. The stationary connector component, which is normally positioned in a panel, is provided with a fiangemount which permits rotary adjustment of the normally stationary connector component to a desired aligned position with respeet to contacts in the other connector component. The fiange-mount which comprises a fiange on the connector component and a clamping ring may then be secured to the panel by drawing the clamping ring tightly against the flange, thus binding the latter between the ring and the panel for securing the eomponent in desired fixed position. (AEC)

  2. Cable tester

    NASA Astrophysics Data System (ADS)

    Rammage, Robert L.

    1990-10-01

    A device for sequentially testing the plurality of connectors in a wiring harness is disclosed. The harness is attached to the tester by means of adapter cables and a rotary switch is used to sequentially, individually test the connectors by passing a current through the connector. If the connector is unbroken, a light will flash to show it is electrically sound. The adapters allow a large number of cable configurations to be tested using a single tester configuration.

  3. Connector acts as quick coupling in coaxial cable application

    NASA Technical Reports Server (NTRS)

    Brejcha, A. G., Jr.

    1966-01-01

    Quick-coupling connector whose inner shells are threaded to the cable ends and whose outer shells have tracks that register in channels machined in the inner shells are rotated 45 deg to effect a locking of the coupling. This connector faithfully reproduces excellent electrical characteristics no matter how frequently assembled and disassembled.

  4. Microfabricated Electrical Connector for Atomic Force Microscopy Probes with Integrated Sensor/Actuator

    NASA Astrophysics Data System (ADS)

    Akiyama, Terunobu; Staufer, Urs; Rooij, Nico F. de

    2002-06-01

    A microfabricated, electrical connector is proposed for facilitating the mounting of atomic force microscopy (AFM) probes, which have an integrated sensor and/or actuator. Only a base chip, which acts as a socket, is permanently fixed onto a printed circuit board and electronically connected by standard wire bonding. The AFM chip, the “plug”, is flipped onto the base chip and pressed from the backside by a spring. Electrical contact with the eventual stress sensors, capacitive or piezoelectric sensor/actuators, is provided by contact bumps. These bumps of about 8 μm height are placed onto the base chip. They touch the pads on the AFM chip that were originally foreseen to be for wire bonding and thus provide the electrical contact. This connector schema was successfully used to register AFM images with piezoresistive cantilevers.

  5. High current capacity electrical connector

    DOEpatents

    Bettis, Edward S.; Watts, Harry L.

    1976-01-13

    An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a "sandwiched" configuration in which a conductor plate contacts the busses along major surfaces thereof clamped between two stainless steel backing plates. The conductor plate is provided with a plurality of contact buttons affixed therein in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors.

  6. Dust and Debris Tolerant Retractable Cover Connector

    NASA Technical Reports Server (NTRS)

    Lewis, Mark E. (Inventor); Dokos, Adam G. (Inventor); Townsend, III, Ivan I. (Inventor); Carlson, Jeffrey W. (Inventor); Bastin, Gary L. (Inventor); Murtland, Kevin A. (Inventor)

    2017-01-01

    A debris exclusion and removal apparatus for connectors which have retractable cover configurations which include internal wafers that clean the connectors prior to mating. XXXX connectors. More particularly, embodiments relate to dust tolerant connectors. Some embodiments also relate to an intelligent connector system capable of detecting damage to or faults within a conductor and then rerouting the energy to a non-damaged spare conductor. Discussion Connectors of the present invention may be used to transfer electrical current, fluid, and gas in a wide variety of environments containing dust and other debris, wherein that debris may present substantial challenges. For example, lunar/Martian dust intrusion and/or accumulation in connectors used to transfer oxygen, hydrogen, nitrogen, etc., may lead to larger system failures as well as loss of life in extraterrestrial human exploration endeavors. Additionally, embodiments of the present invention may also be suitable for use where connectors must resist water intrusion, such as terrestrial deep water operations.

  7. Electrical-splicing connector

    NASA Technical Reports Server (NTRS)

    Stringer, E. J.

    1977-01-01

    Connection can be made without removing insulation, and connector case insulates splice. Device can be made in various sizes and saves time, especially when working on prototype boards with several interconnecting test leads.

  8. The radiation impedance of an electrodynamic tether with end connectors

    NASA Technical Reports Server (NTRS)

    Hastings, Daniel E.; Wang, J.

    1987-01-01

    Electrodynamic tethers are wires deployed across the earth's geomagnetic field through which a current is flowing. The radiation impedance of a tether with end connectors carrying an ac current is computed from classical antenna theory. This simulates the use of a tether on a space structure. It is shown that the current flow pattern at the tether connector is critical to determining the overall radiation impedance. If the tether makes direct electrical contact with the ionosphere then radiation impedances of the order of several thousand Ohms can be expected. If the only electrical contact is through the end connectors then the impedance is only a few Ohms for a dc current rising to several tens of Ohms for an ac current with frequencies in the whistler range.

  9. Method and Apparatus for Obtaining a Precision Thickness in Semiconductor and Other Wafers

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S. (Inventor)

    2002-01-01

    A method and apparatus for processing a wafer comprising a material selected from an electrical semiconducting material and an electrical insulating material is presented. The wafer has opposed generally planar front and rear sides and a peripheral edge, wherein said wafer is pressed against a pad in the presence of a slurry to reduce its thickness. The thickness of the wafer is controlled by first forming a recess such as a dimple on the rear side of the wafer. A first electrical conducting strip extends from a first electrical connection means to the base surface of the recess to the second electrical connector. The first electrical conducting strip overlies the base surface of the recess. There is also a second electrical conductor with an electrical potential source between the first electrical connector and the second electrical connector to form. In combination with the first electrical conducting strip, the second electrical conductor forms a closed electrical circuit, and an electrical current flows through the closed electrical circuit. From the front side of the wafer the initial thickness of the wafer is reduced by lapping until the base surface of the recess is reached. The conductive strip is at least partially removed from the base surface to automatically stop the lapping procedure and thereby achieve the desired thickness.

  10. Process for making RF shielded cable connector assemblies and the products formed thereby

    NASA Technical Reports Server (NTRS)

    Fisher, A.; Clatterbuck, C. H. (Inventor)

    1973-01-01

    A process for making RF shielded cable connector assemblies and the resulting structures is described. The process basically consists of potting wires of a shielded cable between the cable shield and a connector housing to fill in, support, regidize, and insulate the individual wires contained in the cable. The formed potting is coated with an electrically conductive material so as to form an entirely encompassing adhering conductive path between the cable shield and the metallic connector housing. A protective jacket is thereby formed over the conductive coating between the cable shield and the connector housing.

  11. Salt Spray Test to Determine Galvanic Corrosion Levels of Electroless Nickel Connectors Mounted on an Aluminum Bracket

    NASA Technical Reports Server (NTRS)

    Rolin, T. D.; Hodge, R. E.; Torres, P. D.; Jones, D. D.; Laird, K. R.

    2014-01-01

    During preliminary vehicle design reviews, requests were made to change flight termination systems from an electroless nickel (EN) connector coating to a zinc-nickel (ZN) plating. The reason for these changes was due to a new NASA-STD-6012 corrosion requirement where connectors must meet the performance requirement of 168 hr of exposure to salt spray. The specification for class F connectors, MIL-DTL-38999, certifies the EN coating will meet a 48-hr salt spray test, whereas the ZN is certified to meet a 168-hr salt spray test. The ZN finish is a concern because Marshall Space Flight Center has no flight experience with ZN-finished connectors, and MSFC-STD-3012 indicates that zinc and zinc alloys should not be used. The purpose of this test was to run a 168-hr salt spray test to verify the electrical and mechanical integrity of the EN connectors and officially document the results. The salt spray test was conducted per ASTM B117 on several MIL-DTL-38999 flight-like connectors mounted to an aluminum 6061-T6 bracket that was alodined. The configuration, mounting techniques, electrical checks, and materials used were typical of flight and ground support equipment.

  12. Reference Manual on Interference Seals and Connectors for Undersea Electrical Applications

    DTIC Science & Technology

    1976-07-01

    processes. It has a standard line of metal shell connectors, the ER and EB series, which are available with braided and laced harnass work and breakouts, and...Assemblies (RM) 4-10 4.3.2 Molded Plastic Assemblies (PM) 4-11 4.3.3 Metal Shell Assemblies (MS) 4-12 4.3.4 Pressure-balanced Oil-filled Assemblies...connectors according to material composition. The classes of connectors include: Rubber Molded (RM), Plastic Molded (PM), Metal Shell (MS), Pressure-Balanced

  13. Breakdown-Resistant RF Connectors for Vacuum

    NASA Technical Reports Server (NTRS)

    Caro, Edward R.; Bonazza, Walter J.

    1987-01-01

    Resilient inserts compensate for insulation shrinkage. Coaxial-cable connector for radio-frequency (RF) energy resists electrical breakdown in vacuum. Used on RF equipment in vacuum chambers as well as in spaceborne radar and communication gear.

  14. Investigation of problems associated with solid encapsulation of high voltage electronic assemblies; also Reynolds connector study

    NASA Technical Reports Server (NTRS)

    Bever, R. S.

    1975-01-01

    Electric breakdown prevention in vacuum and encapsulation of high voltage electronic circuits was studied. The lap shear method was used to measure adhesive strengths. The permeation constants of air at ambient room temperature through four different space-grade encapsulants was measured. Order of magnitude was calculated for the time that air bubble pressures drop to the corona region. High voltage connectors with L-type cable attached were tested in a vacuum system at various pressures. The cable system was shown to suppress catastrophic breakdown when filled with and surrounded by gas in the corona region of pressures, but did not prove to be completely noise free.

  15. Hazardous Waste Cleanup: Amphenol Corporation-Benedix Connector Division in Sidney, New York

    EPA Pesticide Factsheets

    Amphenol Corporation is primarily a manufacturer of electrical components and connectors for the aircraft and aerospace industries. Hazardous wastes are generated through electroplating, vapor degreasing and parts-cleaning operations. Hazardous waste

  16. Update on Alternatives for Cadmium Coatings on Military Electrical Connectors

    DTIC Science & Technology

    2010-03-01

    Update on Alternatives for Cadmium Coatings on Military Electrical Connectors The metal finishing industry hasbeen impacted by numerous reg- ulatory...government agen- cies to reduce the quantity of toxic and hazardous chemicals and materi- als acquired, used, or disposed. Cadmium and hexavalent...of cadmium and hexavalent chromium in ground vehicles and related systems. The National Defense Center for Energy and Environment (NDCEE), operated

  17. For current viewing resistor loads

    DOEpatents

    Lyons, Gregory R [Tijeras, NM; Hass, Jay B [Lee's Summit, MO

    2011-04-19

    The invention comprises a terminal unit for a flat cable comprising a BNC-PCB connector having a pin for electrically contacting one or more conducting elements of a flat cable, and a current viewing resistor having an opening through which the pin extends and having a resistor face that abuts a connector face of the BNC-PCB connector, wherein the device is a terminal unit for the flat cable.

  18. Low inductance connector assembly

    DOEpatents

    Holbrook, Meghan Ann; Carlson, Douglas S

    2013-07-09

    A busbar connector assembly for coupling first and second terminals on a two-terminal device to first and second contacts on a power module is provided. The first terminal resides proximate the first contact and the second terminal resides proximate the second contact. The assembly comprises a first bridge having a first end configured to be electrically coupled to the first terminal, and a second end configured to be electrically coupled to the second contact, and a second bridge substantially overlapping the first bridge and having a first end electrically coupled to the first contact, and a second end electrically coupled to the second terminal.

  19. Data Transmission System For A Downhole Component

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Fox, Joe; Briscoe, Michael

    2005-01-18

    The invention is a system for transmitting data through a string of downhole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each component has a first and second end, with a first communication element located at the first end and a second communication element located at the second end. Each communication element includes a first contact and a second contact. The system also includes a coaxial cable running between the first and second communication elements, the coaxial cable having a conductive tube and a conductive core within it. The system also includes a first and second connector for connecting the first and second communication elements respectively to the coaxial cable. Each connector includes a conductive sleeve, lying concentrically within the conductive tube, which fits around and makes electrical contact with the conductive core. The conductive sleeve is electrically isolated from the conductive tube. The conductive sleeve of the first connector is in electrical contact with the first contact of the first communication element, the conductive sleeve of the second connector is in electrical contact with the first contact of the second communication element, and the conductive tube is in electrical contact with both the second contact of the first communication element and the second contact of the second communication element.

  20. Data transmission system for a downhole component

    DOEpatents

    Hall, David R.; Hall, Jr., Tracy H.; Pixton, David S.; Dahlgren, Scott Steven; Fox, Joe; Sneddon, Cameron; Briscoe, Michael A.

    2006-05-09

    The invention is a system for transmitting data through a string of downhole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. Each component has a first and second end, with a first communication element located at the first end and a second communication element located at the second end. Each communication element includes a first contact and a second contact. The system also includes a coaxial cable running between the first and second communication elements, the coaxial cable having a conductive tube and a conductive core within it. The system also includes a first and second connector for connecting the first and second communication elements respectively to the coaxial cable. Each connector includes a conductive sleeve, lying concentrically within the conductive tube, which fits around and makes electrical contact with the conductive core. The conductive sleeve is electrically isolated from the conductive tube. The conductive sleeve of the first connector is in electrical contact with the first contact of the first communication element, the conductive sleeve of the second connector is in electrical contact with the first contact of the second communication element, and the conductive tube is in electrical contact with both the second contact of the first communication element and the second contact of the second communication element.

  1. KSC-07pd3652

    NASA Image and Video Library

    2007-12-21

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a United Space Alliance technician carefully cuts away the foam insulation surrounding the covers over the feed-through connector box on the external tank for space shuttle Atlantis' STS-122 mission. The covers will be removed for access to the feed-through connectors. Following the failure of some of the tank's engine cutoff sensors, or ECO sensors, during propellant tanking for launch attempts on Dec. 6 and Dec. 9, a tanking test was conducted on Dec. 18 to aid in troubleshooting the cause. Technicians spliced test wiring into the ECO sensor electrical system and used time domain reflectometry equipment to help locate the electrical anomaly. Results of the tanking test pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. During the holiday period, workers from Lockheed Martin will begin inspecting and testing the connector. Shuttle program managers will meet on Dec. 27 to review the test and analysis, and decide on a forward plan. Photo credit: NASA/Kim Shiflett

  2. The design and evaluation of superconducting connectors

    NASA Technical Reports Server (NTRS)

    Payne, J. E.

    1982-01-01

    The development of a superconducting connector for superconducting circuits on space flights is described. It is proposed that such connectors be used between the superconducting readout loop and the SQUID magnetometer in the Gravity Probe B experiment. Two types of connectors were developed. One type employs gold plated niobium wires making pressure connections to gold plated niobium pads. Lead-plated beryllium-copper spring contacts can replace the niobium wires. The other type is a rigid solder or weld connection between the niobium wires and the niobium pads. A description of the methods used to produce these connectors is given and their performance analyzed.

  3. Umbilical mechanism assembly for the international space station

    NASA Technical Reports Server (NTRS)

    Mandvi, A. Ali

    1996-01-01

    Mechanisms for engaging and disengaging electrical and fluid line connectors are required to be operated repeatedly in hazardous or remote locations on space station, nuclear reactors, toxic chemical and undersea environments. Such mechanisms may require shields to protect the mating faces of the connectors when connectors are not engaged and move these shields out of the way during connector engagement. It is desirable to provide a force-transmitting structure to react the force required to engage or disengage the connectors. It is also desirable that the mechanism for moving the connectors and shields is reliable, simple, and the structure as lightweight as possible. With these basic requirements, an Umbilical Mechanism Assembly (UMA) was originally designed for the Space Station Freedom and now being utilized for the International Space Station.

  4. Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

    NASA Technical Reports Server (NTRS)

    Das, H.; Zak, H.; Kim, W. S.; Bejczy, A. K.; Schenker, P. S.

    1992-01-01

    Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

  5. Comparison of Predicted and Measured Towline Tensions

    DTIC Science & Technology

    1994-05-01

    10 volts DC Calibration Error Less than 0.25% of full capacity Material Stainless Steel The installed configuration of the load cell at the tow end is...capacity zero shift per IF over operating temperature range. Construction- Stainless steel , seal welded. Electrical Connector- Brantner MSJ-4-BCR...Manufacturer- Marsh & MarineTm Connectors 150 Manufacturer’s Part #- RM-4-MP Description- Molded in-line female connector with stainless steel

  6. Structural health monitoring of compression connectors for overhead transmission lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hong; Wang, Jy-An John; Swindeman, Joseph P

    Two-stage aluminum conductor steel-reinforced (ACSR) compression connectors are extensively used in US overhead transmission lines. The connectors are made by crimping a steel sleeve onto a steel core and an aluminum sleeve over aluminum conductive strands. The connectors are designed to operate at temperatures up to 125 C, but their performance is increasingly degrading because of overloading of lines. Currently, electric utilities conduct routine line inspections using thermal and electrical measurements. However, information about the structural integrity of connectors cannot be obtained. In this work, structural health monitoring (SHM) of compression connectors was studied using electromechanical impedance (EMI) analysis. Leadmore » zirconate titanate (PZT)-5A was identified as a smart material for SHM. A flexible high-temperature bonding layer was used to address challenges in PZT integration due to a significant difference in the coefficients of thermal expansion of PZT and the aluminum substrate. The steel joint on the steel core was investigated because it is responsible for the ultimate tensile strength of the connector. Tensile testing was used to create structural damage to the joint, or steel core pullout, and thermal cycling introduced additional structural perturbations. EMI measurements were conducted between the tests. The root mean square deviation (RMSD) of EMI was identified as a damage index. The use of steel joints has been shown to enable SHM under simulated conditions. The EMI signature is sensitive to variations in structural conditions. RMSD can be correlated to the structural health of a connector and has potential for use in the SHM and structural integrity evaluation.« less

  7. Tandem Organic Light-Emitting Diodes.

    PubMed

    Fung, Man-Keung; Li, Yan-Qing; Liao, Liang-Sheng

    2016-12-01

    A tandem organic light-emitting diode (OLED) is an organic optoelectronic device that has two or more electroluminescence (EL) units connected electrically in series with unique intermediate connectors within the device. Researchers have studied this new OLED architecture with growing interest and have found that the current efficiency of a tandem OLED containing N EL units (N > 1) should be N times that of a conventional OLED containing only a single EL unit. Therefore, this new architecture is potentially useful for constructing high-efficiency, high-luminance, and long-lifetime OLED displays and organic solid-state lighting sources. In a tandem OLED, the intermediate connector plays a crucial role in determining the effectiveness of the stacked EL units. The interfaces in the connector control the inner charge generation and charge injection into the adjacent EL units. Meanwhile, the transparency and the thickness of the connector affect the light output of the device. Therefore, the intermediate connector should be made to meet both the electrical and optical requirements for achieving optimal performance. Here, recent advances in the research of the tandem OLEDs is discussed, with the main focus on material selection and interface studies in the intermediate connectors, as well as the optical design of the tandem OLEDs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Service equipment for use in hostile environments

    NASA Technical Reports Server (NTRS)

    Dolce, James L. (Inventor); Gordon, Andrew L. (Inventor)

    1994-01-01

    Service equipment for use in hostile environments includes a detachable service unit secured to a stationary service unit. The detachable service unit includes a housing with an exterior plate, a power control interface for connection to an exterior power source, locating pins located in said exterior plate, an electrical connector in the exterior plate electrically coupled to said power control interface, and a pair of clamping receptacles formed in the exterior plate and located on adjacent opposite edges of the exterior plate. The stationary unit includes an electrical connector for connection to the electrical connector of the detachable service unit, a clamping apparatus for clamping and unclamping the detachable service unit from the stationary unit, a base clamp assembly for mounting the clamping apparatus onto the stationary unit, and locating pin holes for receiving the locating pins and aligning the detachable service unit onto the stationary unit. The detachable service unit and stationary unit have mating scalloped faces which aid in alignment and provide a mechanism for heat dissipation.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, Ines; Schillig, Cora

    A double-sided adhesive metal-based tape for use as contacting aid for SOFC fuel cells is provided. The double-sided metal-based adhesive tape is suitable for simplifying the construction of cell bundles. The double-sided metal-based adhesive tape is used for electrical contacting of the cell connector with the anode and for electrical contacting of the interconnector of the fuel cells with the cell connector. A method for producing the double-sided adhesive metal-base tape is also provided.

  10. The use of pure carbon for permanent percutaneous electrical connector systems

    NASA Technical Reports Server (NTRS)

    Mooney, V.; Hartmann, D. B.; Mcneal, D.; Benson, J.

    1973-01-01

    Pure carbon was used as an electrode in the clinical application of long-term neuromuscular stimulation, as well as a connector for permanent neuroelectrodes. The history of this material and some examples of the material in use are presented.

  11. KSC-07pd3655

    NASA Image and Video Library

    2007-12-21

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a United Space Alliance technician carefully cuts away the foam insulation surrounding the covers over the feed-through connector box on the external tank for space shuttle Atlantis' STS-122 mission, revealing the fastener holes on the covers. The covers will be removed for access to the feed-through connectors. Following the failure of some of the tank's engine cutoff sensors, or ECO sensors, during propellant tanking for launch attempts on Dec. 6 and Dec. 9, a tanking test was conducted on Dec. 18 to aid in troubleshooting the cause. Technicians spliced test wiring into the ECO sensor electrical system and used time domain reflectometry equipment to help locate the electrical anomaly. Results of the tanking test pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. During the holiday period, workers from Lockheed Martin will begin inspecting and testing the connector. Shuttle program managers will meet on Dec. 27 to review the test and analysis, and decide on a forward plan. Photo credit: NASA/Kim Shiflett

  12. KSC-07pd3654

    NASA Image and Video Library

    2007-12-21

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a United Space Alliance technician carefully cuts away the foam insulation surrounding the covers over the feed-through connector box on the external tank for space shuttle Atlantis' STS-122 mission, revealing the fastener holes on the covers. The covers will be removed for access to the feed-through connectors. Following the failure of some of the tank's engine cutoff sensors, or ECO sensors, during propellant tanking for launch attempts on Dec. 6 and Dec. 9, a tanking test was conducted on Dec. 18 to aid in troubleshooting the cause. Technicians spliced test wiring into the ECO sensor electrical system and used time domain reflectometry equipment to help locate the electrical anomaly. Results of the tanking test pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. During the holiday period, workers from Lockheed Martin will begin inspecting and testing the connector. Shuttle program managers will meet on Dec. 27 to review the test and analysis, and decide on a forward plan. Photo credit: NASA/Kim Shiflett

  13. KSC-07pd3656

    NASA Image and Video Library

    2007-12-21

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a United Space Alliance technician removes foam insulation revealing the fastener holes on the covers over the feed-through connector box on the external tank for space shuttle Atlantis' STS-122 mission. The covers will be removed for access to the feed-through connectors. Following the failure of some of the tank's engine cutoff sensors, or ECO sensors, during propellant tanking for launch attempts on Dec. 6 and Dec. 9, a tanking test was conducted on Dec. 18 to aid in troubleshooting the cause. Technicians spliced test wiring into the ECO sensor electrical system and used time domain reflectometry equipment to help locate the electrical anomaly. Results of the tanking test pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. During the holiday period, workers from Lockheed Martin will begin inspecting and testing the connector. Shuttle program managers will meet on Dec. 27 to review the test and analysis, and decide on a forward plan. Photo credit: NASA/Kim Shiflett

  14. KSC-07pd3653

    NASA Image and Video Library

    2007-12-21

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, the foam insulation surrounding the covers over the feed-through connector box on the external tank for space shuttle Atlantis' STS-122 mission is carefully cut away by a United Space Alliance technician. The covers will be removed for access to the feed-through connectors. Following the failure of some of the tank's engine cutoff sensors, or ECO sensors, during propellant tanking for launch attempts on Dec. 6 and Dec. 9, a tanking test was conducted on Dec. 18 to aid in troubleshooting the cause. Technicians spliced test wiring into the ECO sensor electrical system and used time domain reflectometry equipment to help locate the electrical anomaly. Results of the tanking test pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. During the holiday period, workers from Lockheed Martin will begin inspecting and testing the connector. Shuttle program managers will meet on Dec. 27 to review the test and analysis, and decide on a forward plan. Photo credit: NASA/Kim Shiflett

  15. High density printed electrical circuit board card connection system

    DOEpatents

    Baumbaugh, Alan E.

    1997-01-01

    A zero insertion/extraction force printed circuit board card connection system comprises a cam-operated locking mechanism disposed along an edge portion of the printed circuit board. The extrusions along the circuit board mate with an extrusion fixed to the card cage having a plurality of electrical connectors. The card connection system allows the connectors to be held away from the circuit board during insertion/extraction and provides a constant mating force once the circuit board is positioned. The card connection system provides a simple solution to the need for a greater number of electrical signal connections.

  16. Analytical study of electrical disconnect system for use on manned and unmanned missions

    NASA Technical Reports Server (NTRS)

    Rosener, A. A.; Lenda, J. A.; Trummer, R. O.

    1976-01-01

    The objective of this contract is to establish an optimum electrical disconnect system design(s) for use on manned and unmanned missions. The purpose of the disconnect system is to electrically mate and demate the spacecraft to subsystem module interfaces to accomplish orbital operations. The results of Task 1 and Task 2 of the effort are presented. Task 1 involves the definition of the functional, operational, and environmental requirements for the connector system to support the leading prototype candidate concepts. Task 2 involves the documentation review and survey of available existing connector designs.

  17. Fiber optics for aircraft engine/inlet control

    NASA Technical Reports Server (NTRS)

    Baumbick, R. J.

    1981-01-01

    NASA programs that focus on the use of fiber optics for aircraft engine/inlet control are reviewed. Fiber optics for aircraft control is attractive because of its inherent immunity to EMI and RFI noise. Optical signals can be safely transmitted through areas that contain flammable or explosive materials. The use of optics also makes remote sensing feasible by eliminating the need for electrical wires to be connected between sensors and computers. Using low-level optical signals to control actuators is also feasible when power is generated at the actuator. Each application of fiber optics for aircraft control has different requirements for both the optical cables and the optical connectors. Sensors that measure position and speed by using slotted plates can use lossy cables and bundle connectors if data transfer is in the parallel mode. If position and speed signals are multiplexed, cable and connector requirements change. Other sensors that depend on changes in transmission through materials require dependable characteristics of both the optical cables and the optical connectors. A variety of sensor types are reviewed, including rotary position encoders, tachometers, temperature sensors, and blade tip clearance sensors for compressors and turbines. Research on a gallium arsenide photoswitch for optically switched actuators that operate at 250 C is also described.

  18. Rotatable electric cable connecting system

    NASA Technical Reports Server (NTRS)

    Manges, D. R. (Inventor)

    1985-01-01

    A cable reel assembly is described which is particularly adapted for, but not limited to, a system for providing electrical connection of power and data signals between an orbiter vehicle, such as a space shuttle, and a recovered satellite. The assembly is comprised of two mutually opposing ring type structures having 180 deg relative rotation with one of the structures being held in fixed position while the other structure is rotatable. Motor controlled berthing latches and umbilical cable connectors for the satellite are located on the rim of the rotatable ring structure. The electrical cable assembly is fed in two sections from the orbiter vehicle into the outer rim portion of the fixed ring structure where they are directed inwardly and attached to two concentrically coiled metal bands whose respective ends are secured to inner and outer post members of circular sets of guide pins located on opposing circular plate members, one rotatable and one fixed. The cable sections are fed out as three output cable sections through openings in the central portion of the circular plate of the rotatable ring structure where they are directed to the latches and connectors located on its rim.

  19. Easily-wired toggle switch

    NASA Technical Reports Server (NTRS)

    Dean, W. T.; Stringer, E. J.

    1979-01-01

    Crimp-type connectors reduce assembly and disassembly time. With design, no switch preparation is necessary and socket contracts are crimped to wires inserted in module attached to back of toggle switch engaging pins inside module to make electrical connections. Wires are easily removed with standard detachment tool. Design can accommodate wires of any gage and as many terminals can be placed on switch as wire gage and switch dimensions will allow.

  20. Percutaneous multiple electrode connector, design parameters and fabrication (biomedical)

    NASA Technical Reports Server (NTRS)

    Myers, L. A.

    1977-01-01

    A percutaneous multielectrode connector was designed which utilizes an ultrapure carbon collar to provide an infection free biocompatible passage through the skin. The device provides reliable electrical continuity, mates and demates readily with the implant, and is fabricated with processes and materials oriented to commercial production.

  1. Low resistance, low-inductance power connectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coteus, Paul W.; Ferencz, Andrew; Hall, Shawn Anthony

    An electrical connector includes an anode assembly for conducting an electrical supply current from a source to a destination, the anode assembly includes an anode formed into a first shape from sheet metal or other sheet-like conducting material. A cathode assembly conducts an electrical return current from the destination to the source, the cathode assembly includes a cathode formed into a second shape from sheet metal or other sheet-like conducting material. An insulator prevents electrical conduction between the anode and the cathode. The first and second shapes are such as to provide a conformity of one to the other, withmore » the insulator therebetween having a predetermined relatively thin thickness. A predetermined low-resistance path for the supply current is provided by the anode, a predetermined low-resistance path for the return current is provided by the cathode, and the proximity of the anode to the cathode along these paths provides a predetermined low self-inductance of the connector, where the proximity is afforded by the conformity of the first and second shapes.« less

  2. Photovoltaic system with improved DC connections and method of making same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cioffi, Philip Michael; Todorovic, Maja Harfman; Herzog, Michael Scott

    A micro-inverter assembly includes a housing having an opening formed in a bottom surface thereof, and a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing at a position adjacent to the opening. The micro-inverter assembly further includes a micro-inverter DC connector electrically coupled to the DC-to-AC micro-inverter and positioned within the opening of the housing, the micro-inverter DC connector having a plurality of exposed electrical contacts.

  3. Photovoltaic sheathing element with a flexible connector assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langmaid, Joseph A; Keenihan, James R; Mills, Michael E

    2016-07-12

    The present invention is premised upon an assembly including at least a photovoltaic sheathing element capable of being affixed on a building structure, the sheathing element including at least: a photovoltaic cell assembly, a body portion attached to one or more portions of the photovoltaic cell assembly; at least a first and a second connector assembly disposed on opposing sides of the sheathing element and capable of directly or indirectly electrically connecting the photovoltaic cell assembly to at least two adjoining devices that are affixed to the building structure and wherein at least one of the connector assemblies includes amore » flexible portion; one or more connector pockets disposed in the body portion the pockets capable of receiving at least a portion of the connector assembly.« less

  4. Development of robots and application to industrial processes

    NASA Technical Reports Server (NTRS)

    Palm, W. J.; Liscano, R.

    1984-01-01

    An algorithm is presented for using a robot system with a single camera to position in three-dimensional space a slender object for insertion into a hole; for example, an electrical pin-type termination into a connector hole. The algorithm relies on a control-configured end effector to achieve the required horizontal translations and rotational motion, and it does not require camera calibration. A force sensor in each fingertip is integrated with the vision system to allow the robot to teach itself new reference points when different connectors and pins are used. Variability in the grasped orientation and position of the pin can be accomodated with the sensor system. Performance tests show that the system is feasible. More work is needed to determine more precisely the effects of lighting levels and lighting direction.

  5. Dust Tolerant Connectors

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P. (Inventor); Lewis, Mark E. (Inventor); Bastin, Gary L. (Inventor); Branch, Matthew C. (Inventor); Carlson, Jeffrey W. (Inventor); Dokos, Adam G. (Inventor); Murtland, Kevin A. (Inventor); Nugent, Matthew W. (Inventor); Tamasy, Gabor J. (Inventor); Townsend, III, Ivan I. (Inventor)

    2016-01-01

    Methods and systems may provide for debris exclusion and removal apparatuses for connectors which have inverting end caps with a multi-axis lever configuration, inverting end caps with enlarged handle and/or side rail configurations, rotating end cap configurations, poppet valve configurations, O-ring configurations, filament barrier configurations, retractable cover configurations, clamshell end cap configurations, or any combination thereof. Apparatuses may also provide for an intelligent electrical connector system capable of detecting damage to or faults within a plurality of conductors and then rerouting the energy through a non-damaged spare conductor.

  6. Acoustic vibration test detects intermittent electrical discontinuities

    NASA Technical Reports Server (NTRS)

    Grieve, S. M.; Roberts, D. E.

    1970-01-01

    Nondestructive test method detects faulty electrical connections in inaccessible or hidden portions of electronic harness assemblies and connectors. Method employs readily available commercial equipment.

  7. Zipper Connectors for Flexible Electronic Circuits

    NASA Technical Reports Server (NTRS)

    Barnes, Kevin N.

    2003-01-01

    Devices that look and function much like conventional zippers on clothing have been proposed as connectors for flexible electronic circuits. Heretofore, flexible electronic circuits have commonly included rigid connectors like those of conventional rigid electronic circuits. The proposed zipper connectors would make it possible to connect and disconnect flexible circuits quickly and easily. Moreover, the flexibility of zipper connectors would make them more (relative to rigid connectors) compatible with flexible circuits, so that the advantages of flexible circuitry could be realized more fully. Like a conventional zipper, a zipper according to the proposal would include teeth anchored on flexible tapes, a slider with a loosely attached clasp, a box at one end of the rows of mating teeth, and stops at the opposite ends. The tapes would be made of a plastic or other dielectric material. On each of the two mating sides of the zipper, metal teeth would alternate with dielectric (plastic) teeth, there being two metal teeth for each plastic one. When the zipper was closed, each metal tooth from one side would be in mechanical and electrical contact with a designated metal tooth from the other side, and these mating metal teeth would be electrically insulated from the next pair of mating metal teeth by an intervening plastic tooth. The metal teeth would be soldered or crimped to copper tabs. Wires or other conductors connected to electronic circuits would be soldered or crimped to the ends of the tabs opposite the teeth.

  8. United States Air Force Research Initiation Program. 1985 Technical Report. Volume 1

    DTIC Science & Technology

    1987-04-01

    Classification) USAF Research Initiation Program Volume 1 12. PERSONAL AUTHOR(S) Program Director Rodney C. Darrah 13a. TYPE OF...Maximum Voluntary +land Grip Torque for Circular Electrical Connectors 760-0MG-068 Temperature Dependence of Ion- Molecule Association Reactions...Foster 30 Photothermal and Photochemical Properties of Melanin and Their Role in Light Induced Degrad- ation of the Retina 760-0MG-106 Dr. James

  9. Fiber optical cable and connector system (FOCCoS) for PFS/ Subaru

    NASA Astrophysics Data System (ADS)

    de Oliveira, Antonio Cesar; de Oliveira, Lígia Souza; de Arruda, Marcio V.; Souza Marrara, Lucas; dos Santos, Leandro H.; Ferreira, Décio; dos Santos, Jesulino B.; Rosa, Josimar A.; Junior, Orlando V.; Pereira, Jeferson M.; Castilho, Bruno; Gneiding, Clemens; Junior, Laerte S.; de Oliveira, Claudia M.; Gunn, James; Ueda, Akitoshi; Takato, Naruhisa; Shimono, Atsushi; Sugai, Hajime; Karoji, Hiroshi; Kimura, Masahiko; Tamura, Naoyuki; Wang, Shiang-Yu; Murray, Graham; Le Mignant, David; Madec, Fabrice; Jaquet, Marc; Vives, Sebastien; Fisher, Charlie; Braun, David; Schwochert, Mark; Reiley, Daniel J.

    2014-07-01

    FOCCoS, "Fiber Optical Cable and Connector System" has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition. All optical fibers from Cable C, protected by tubes, pass through the motors' bench plate, three modular plates and a strain relief box, terminating at the Tower Connector. Cable B is permanently installed at Subaru Telescope structure, as a link between Cable C and Cable A. This cable B starts at the Tower Connector device, placed on a lateral structure of the telescope, and terminates at the Gang Connector device. Cable B will be routed to minimize the compression, torsion and bending caused by the cable weight and telescope motion. In the spectrograph room, Cable A starts at the Gang Connector, crosses a distribution box and terminates in a slit device. Each slit device receives approximately 600 optical fibers, linearly arrayed in a curve for better orientation of the light to the spectrograph collimator mirror. Four sets of Gang Connectors, distribution boxes and Slit devices complete one Cable A. This paper will review the general design of the FOCCoS subsystem, methods used to manufacture the involved devices, and the needed tests results to evaluate the total efficiency of the set.

  10. Near Field Imaging for the Characterization of Diffusion Length and Waveguiding in Zinc Oxide Nanowires

    DTIC Science & Technology

    2012-06-01

    From RADAR and SONAR , rocket propulsion, and the atomic bomb in World War II to the high tech drones, satellite imagery, surgically precise weapons...control from the four connectors shown in Figure scanner, preamplifier , step motor, and the bottom scanner. The connectors also electrically ground

  11. Research on HOPE communication and data processing equipment

    NASA Astrophysics Data System (ADS)

    Yamamoto, Satoru; Kikuchi, Toshio

    1992-08-01

    An overview of the research on heat-resisting antenna is presented. Candidate heat-resisting antennas which were selected as the result of review on seven kinds of antenna are the antennas of micro strip, cavity, and horn types. Heat resistance characteristics of electric power supplying section (connectors) of heat-resisting antenna were studied. Heat cycling test and heat shock tests were conducted on the subject plugs and it was confirmed that they can be usable at - 80 C to + 200 C against - 65 C to + 125 C for the existing plugs. Fundamental electric data such as antenna pattern were acquired mating trial produced components simulating electric characteristics of heat-resisting antenna and trial-produced ceramic tiles.

  12. Compact electro-optical module with polymer waveguides on a flexible substrate for high-density board-level communication

    NASA Astrophysics Data System (ADS)

    Weiss, J. R. M.; Lamprecht, T.; Meier, N.; Dangel, R.; Horst, F.; Jubin, D.; Beyeler, R.; Offrein, B. J.

    2010-02-01

    We report on the co-packaging of electrical CMOS transceiver and VCSEL chip arrays on a flexible electrical substrate with optical polymer waveguides. The electro-optical components are attached to the substrate edge and butt-coupled to the waveguides. Electrically conductive silver-ink connects them to the substrate at an angle of 90°. The final assembly contacts the surface of a package laminate with an integrated compressible connector. The module can be folded to save space, requires only a small footprint on the package laminate and provides short electrical high-speed signal paths. With our approach, the electro-optical package becomes a compact electro-optical module with integrated polymer waveguides terminated with either optical connectors (e.g., at the card edge) or with an identical assembly for a second processor on the board. Consequently, no costly subassemblies and connectors are needed, and a very high integration density and scalability to virtually arbitrary channel counts and towards very high data rates (20+ Gbps) become possible. Future cost targets of much less than US$1 per Gbps will be reached by employing standard PCB materials and technologies that are well established in the industry. Moreover, our technology platform has both electrical and optical connectivity and functionality.

  13. KSC-07pd3660

    NASA Image and Video Library

    2007-12-29

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician pulls the connector assembly, with its associated electrical harness, away from the tank. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  14. Magnetic electrical connectors for biomedical percutaneous implants

    NASA Technical Reports Server (NTRS)

    Owens, L. J. (Inventor)

    1977-01-01

    A biomedical percutaneous connector is described which includes a socket having an enlarged disk shaped base portion for being implanted below the patient's skin and cylindrical portion which is integral with the base portion and extends outwardly of the skin. A conical recess in an upper end of the cylindrical portion has a magnet located in the base. Inclined conductive strips are carried on an upper end of the cylindrical portion to which electrical conductors are attached and extend into the patient's body. A complementary shaped plug which also has electrical contacts provided thereon is adapted to fit within the conical recess of the socket. The plug is held in the socket by magnetic force.

  15. Mechanized fluid connector and assembly tool system with ball detents

    NASA Technical Reports Server (NTRS)

    Zentner, Ronald C. (Inventor); Smith, Steven A. (Inventor)

    1991-01-01

    A fluid connector system is disclosed which includes a modified plumbing union having a rotatable member for drawing said union into a fluid tight condition. A drive tool is electric motor actuated and includes a reduction gear train providing an output gear engaging an integral peripheral spur gear on the rotatable member. Coaxial alignment means are attached to both the connector assembly and the drive tool. A hand lever actuated latching system includes a plurality of circumferentially spaced latching balls selectively wedged against the alignment means attached to the connector assembly or to secure the drive tool with its output gear in mesh with the integral peripheral spur gear. The drive motor is torque, speed, and direction controllable.

  16. Vulnerability of Quick Disconnect Connectors to Carbon Fibers

    NASA Technical Reports Server (NTRS)

    Meyers, J. A.

    1979-01-01

    Unprotected quick disconnect electrical connectors were exposed to fibers of 3mm, 7mm, and 12mm lengths. The average exposure to failure was determined. Results indicate that when the fiber length divided by the airgap is less than one, multiple fibers are required to bridge the gap, and the exposure time to failure rises rapidly.

  17. Automatic circuit interrupter

    NASA Technical Reports Server (NTRS)

    Dwinell, W. S.

    1979-01-01

    In technique, voice circuits connecting crew's cabin to launch station through umbilical connector disconnect automatically unused, or deadened portion of circuits immediately after vehicle is launched, eliminating possibility that unused wiring interferes with voice communications inside vehicle or need for manual cutoff switch and its associated wiring. Technique is applied to other types of electrical actuation circuits, also launch of mapped vehicles, such as balloons, submarines, test sleds, and test chambers-all requiring assistance of ground crew.

  18. KSC-08pd0003

    NASA Image and Video Library

    2008-01-04

    KENNEDY SPACE CENTER, FLA. -- At a lab at NASA's Kennedy Space Center, Kevin Wyckoff, an aerospace technician with the United Launch Alliance, inserts an electrical wiring harness into a replacement feed-through connector during preparations to solder the pins to the socket of the connector. The connector will later be installed in the external fuel tank for space shuttle Atlantis' STS-122 mission. The technician performed this exacting task on the Centaur upper stage for Atlas and Titan launches in 1994 and was specifically chosen for the task. Soldering the connector pins and sockets together addresses the most likely cause of a problem in the engine cutoff sensor system, or ECO system. Some of the tank's ECO sensors failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the soldering is completed and the connector is reinstalled, shuttle program managers will decide on how to proceed. The launch date for mission STS-122 is under review. Photo credit: NASA/Kim Shiflett

  19. Experimental investigation on the electrical contact behavior of rolling contact connector.

    PubMed

    Chen, Junxing; Yang, Fei; Luo, Kaiyu; Zhu, Mingliang; Wu, Yi; Rong, Mingzhe

    2015-12-01

    Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.

  20. Miniature electrical connector

    DOEpatents

    Casper, Robert F.

    1976-01-01

    A miniature coaxial cable electrical connector includes an annular compressible gasket in a receptacle member, the gasket having a generally triangular cross section resiliently engaging and encircling a conically tapered outer surface of a plug member to create an elongated current leakage path at their interface; means for preventing rotation of the plug relative to the receptacle; a metal sleeve forming a portion of the receptacle and encircling the plug member when interconnected; and a split ring in the plug having outwardly and rearwardly projecting fingers spaced from and encircling a portion of a coaxial cable and engageable with the metal sleeve to interlock the receptacle and plug.

  1. Electrical Connector for Graphite Heating Elements

    NASA Technical Reports Server (NTRS)

    Mackintosh, B. H.

    1982-01-01

    Connection method applies force to two interfaces: that between heating element proper and heating-element support members and between heating-element support members and metal conductor. Inner rod of new connector system is maintained in tension by a spring (for example, Belleville washers). Connection is sufficiently complaint so tension remains within desired range, regardless of thermal expansion and contraction of various elements.

  2. Improved contact resistance stability in a MEMS separable electrical connector

    NASA Astrophysics Data System (ADS)

    Larsson, M. P.

    2005-12-01

    A MEMS in-line separable electrical connector with improved contact resistance stability to thermal fluctuations and mating cycles is described. The design allows sliding, in-line connection between separate halves, inducing vertical deflections on a set of flexible conductors to establish stable electrical contacts. Features are present on both halves to ensure precise lateral and vertical self-alignment; preventing shorts and maintaining consistent conductor deflections. Characterisation on early prototypes revealed significant variability in contact resistance with thermal fluctuations and mating cycle history. As flexible conductors are multi-layered structures of Au supported by a thick structural layer of Ni, they undergo differential thermal expansion, introducing variability in contact resistance with temperature. Sliding contact wear during repeated mating leads to removal of portions of the Au surface coating, and electrical contact between underlying (non-noble) Ni layers. By using a harder Co-Au alloy as the contact surface layer and modifying the arrangement of constituent conductor layers to balance thermal stresses, improvements to both wear and thermal tolerance of contact resistance can be obtained. Devices implementing the above design modifications show stable contact resistance over 100 mating cycles and an increase in contact resistance of between 3.5 and 7% over a temperature rise of 60°C. The electrical performance improvements increase the attractiveness of the MEMS in-line separable connector concept for applications in portable electronics and MEMS integration.

  3. 40 CFR Appendix A to Part 438 - Typical Products in Metal Products and Machinery Sectors

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Trailers ELECTRONIC EQUIPMENT Communications Equipment Connectors for Electronic Applications Electric... Blades Hardware Heating Equipment, Except Electric Industrial Furnaces & Ovens Iron & Steel Forgings.... & Inst. Elec. Lighting Fixtures Current-Carrying Wiring Devices Electirc Housewares & Fans Electric Lamps...

  4. 40 CFR Appendix A to Part 438 - Typical Products in Metal Products and Machinery Sectors

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Trailers ELECTRONIC EQUIPMENT Communications Equipment Connectors for Electronic Applications Electric... Blades Hardware Heating Equipment, Except Electric Industrial Furnaces & Ovens Iron & Steel Forgings.... & Inst. Elec. Lighting Fixtures Current-Carrying Wiring Devices Electirc Housewares & Fans Electric Lamps...

  5. 14 CFR 23.1365 - Electric cables and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... insulation. (d) Means of identification must be provided for electrical cables, terminals, and connectors. (e... vapors, or sources of heat, is minimized. (f) Where a cable cannot be protected by a circuit protection...

  6. 14 CFR 23.1365 - Electric cables and equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... insulation. (d) Means of identification must be provided for electrical cables, terminals, and connectors. (e... vapors, or sources of heat, is minimized. (f) Where a cable cannot be protected by a circuit protection...

  7. 14 CFR 23.1365 - Electric cables and equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... insulation. (d) Means of identification must be provided for electrical cables, terminals, and connectors. (e... vapors, or sources of heat, is minimized. (f) Where a cable cannot be protected by a circuit protection...

  8. 14 CFR 23.1365 - Electric cables and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... insulation. (d) Means of identification must be provided for electrical cables, terminals, and connectors. (e... vapors, or sources of heat, is minimized. (f) Where a cable cannot be protected by a circuit protection...

  9. 14 CFR 23.1365 - Electric cables and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... insulation. (d) Means of identification must be provided for electrical cables, terminals, and connectors. (e... vapors, or sources of heat, is minimized. (f) Where a cable cannot be protected by a circuit protection...

  10. Driver-receiver combined optical transceiver modules for bidirectional optical interconnection

    NASA Astrophysics Data System (ADS)

    Park, Hyo-Hoon; Kang, Sae-Kyoung; Kim, Do-Won; Nga, Nguyen T. H.; Hwang, Sung-Hwan; Lee, Tae-Woo

    2008-02-01

    We review a bidirectional optical link scheme for memory-interface applications. A driver-receiver combined optical transceiver (TRx) modules was demonstrated on an optical printed-circuit board (OPCB) platform. To select the bidirectional electric input/output signals, a driver-receiver combined TRx IC with a switching function was designed in 0.18-μm CMOS technology. The TRx IC was integrated with VCSEL/PD chips for optical link in the TRx module. The optical TRx module was assembled on a fiber-embedded OPCB, employing a 90°-bent fiber connector for 90° deflection of light beams between the TRx module and the OPCB. The TRx module and the 90° connector were passively assembled on the OPCB, using ferrule-type guide pins/ holes. Employing these constituent components, the bidirectional optical link between a pair of TRx modules has been successfully demonstrated up to 1.25 Gb/s on the OPCB.

  11. SEE Design Guide and Requirements for Electrical Deadfacing

    NASA Technical Reports Server (NTRS)

    Berki, Joe M.; Sargent, Noel; Kauffman, W. (Technical Monitor)

    2002-01-01

    The purpose of this design guide is to present information for understanding and mitigating the potential hazards associated with de-mating and mating powered electrical connectors on space flight vehicles. The process of staging is a necessary function in the launching of space vehicles and in the deployment of satellites, and now in manned assembly of systems in space. During this electrical interconnection process, various environments may be encountered that warrant the restriction of the voltage and current present across the pins of an electrical connector prior to separation, mating, or in a static open non-mated configuration. This process is called deadfacing. These potentially hazardous environments encompass the obvious explosive fuel vapors and human shock hazard, to multiple Electro-Magnetic Interference (EMI) phenomena related to the rapid rate of change in current as well as exposure to Radio Frequency (RF) fields.

  12. Behaviour of steel-concrete composite beams using bolts as shear connectors

    NASA Astrophysics Data System (ADS)

    Tran, Minh-Tung; Nguyen Van Do, Vuong; Nguyen, Tuan-Anh

    2018-04-01

    The paper presents an experimental program on the application of bolts as shear connectors for steel-composite beams. Four steel- concrete composite beams and a reference steel beam were made and tested. The aim of the testing program is to examine which forms of the steel bolts can be used effectively for steel-composite beams. The four types of the bolts include: Type 1 the bolt with the nut at the end; Type 2 the bolt bending at 900 hook; Type 3 the bolt without the nut at the end and Type 4 the bolt with the nut at the end but connected with the steel beam by hand welding in other to be connected with the steel beam by bolt connection as in the first three types. The test results showed that beside the traditional shear connectors like shear studs, angle type, channel type, bolts can be used effectively as the shear connectors in steel-composite beams and the application of bolts in Types 1 and 2 in the composite beams gave the better performance for the tested beam.

  13. Automated Ground Umbilical Systems (AGUS) Project

    NASA Technical Reports Server (NTRS)

    Gosselin, Armand M.

    2007-01-01

    All space vehicles require ground umbilical systems for servicing. Servicing requirements can include, but are not limited to, electrical power and control, propellant loading and venting, pneumatic system supply, hazard gas detection and purging as well as systems checkout capabilities. Of the various types of umbilicals, all require several common subsystems. These typically include an alignment system, mating and locking system, fluid connectors, electrical connectors and control !checkout systems. These systems have been designed to various levels of detail based on the needs for manual and/or automation requirements. The Automated Ground Umbilical Systems (AGUS) project is a multi-phase initiative to develop design performance requirements and concepts for launch system umbilicals. The automation aspect minimizes operational time and labor in ground umbilical processing while maintaining reliability. This current phase of the project reviews the design, development, testing and operations of ground umbilicals built for the Saturn, Shuttle, X-33 and Atlas V programs. Based on the design and operations lessons learned from these systems, umbilicals can be optimized for specific applications. The product of this study is a document containing details of existing systems and requirements for future automated umbilical systems with emphasis on design-for-operations (DFO).

  14. Connector device for building integrated photovoltaic device

    DOEpatents

    Keenihan, James R.; Langmaid, Joe A.; Eurich, Gerald K.; Lesniak, Michael J.; Mazor, Michael H.; Cleerman, Robert J.; Gaston, Ryan S.

    2015-11-10

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV devices or photovoltaic system components and/or locate these devices/components upon a building structure. It also may optionally provide some additional sub-components (e.g. at least one bypass diode and/or an indicator means) and may enhance the serviceability of the device.

  15. Connector device for building integrated photovoltaic device

    DOEpatents

    Keenihan, James R.; Langmaid, Joseph A.; Eurich, Gerald K.; Lesniak, Michael J.; Mazor, Michael H.; Cleereman, Robert J.; Gaston, Ryan S.

    2014-06-03

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV devices or photovoltaic system components and/or locate these devices/components upon a building structure. It also may optionally provide some additional sub-components (e.g. at least one bypass diode and/or an indicator means) and may enhance the serviceability of the device.

  16. KSC-08pd0005

    NASA Image and Video Library

    2008-01-04

    KENNEDY SPACE CENTER, FLA. -- At a lab at NASA's Kennedy Space Center, Bob Arp, an aerospace technician with the United Launch Alliance, inserts a wire from an electrical harness onto the pin of a replacement feed-through connector during preparations to solder the pins to the socket of the connector. The connector will be installed in the external fuel tank for space shuttle Atlantis' STS-122 mission. The technician performed this exacting task on the Centaur upper stage for Atlas and Titan launches in 1994 and was specifically chosen for the task. Soldering the connector pins and sockets together addresses the most likely cause of a problem in the engine cutoff sensor system, or ECO system. Some of the tank's ECO sensors failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the soldering is completed and the connector is reinstalled, shuttle program managers will decide on how to proceed. The launch date for mission STS-122 is under review. Photo credit: NASA/Kim Shiflett

  17. KSC-08pd0002

    NASA Image and Video Library

    2008-01-04

    KENNEDY SPACE CENTER, FLA. -- At a lab at NASA's Kennedy Space Center, Kevin Wyckoff, an aerospace technician with the United Launch Alliance, examines an electrical wiring harness. The harness will be inserted into a replacement feed-through connector during preparations to solder the pins to the socket of the connector. The connector will later be installed in the external fuel tank for space shuttle Atlantis' STS-122 mission. The technician performed this exacting task on the Centaur upper stage for Atlas and Titan launches in 1994 and was specifically chosen for the task. Soldering the connector pins and sockets together addresses the most likely cause of a problem in the engine cutoff sensor system, or ECO system. Some of the tank's ECO sensors failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the soldering is completed and the connector is reinstalled, shuttle program managers will decide on how to proceed. The launch date for mission STS-122 is under review. Photo credit: NASA/Kim Shiflett

  18. Optical interconnect technologies for high-bandwidth ICT systems

    NASA Astrophysics Data System (ADS)

    Chujo, Norio; Takai, Toshiaki; Mizushima, Akiko; Arimoto, Hideo; Matsuoka, Yasunobu; Yamashita, Hiroki; Matsushima, Naoki

    2016-03-01

    The bandwidth of information and communication technology (ICT) systems is increasing and is predicted to reach more than 10 Tb/s. However, an electrical interconnect cannot achieve such bandwidth because of its density limits. To solve this problem, we propose two types of high-density optical fiber wiring for backplanes and circuit boards such as interface boards and switch boards. One type uses routed ribbon fiber in a circuit board because it has the ability to be formed into complex shapes to avoid interfering with the LSI and electrical components on the board. The backplane is required to exhibit high density and flexibility, so the second type uses loose fiber. We developed a 9.6-Tb/s optical interconnect demonstration system using embedded optical modules, optical backplane, and optical connector in a network apparatus chassis. We achieved 25-Gb/s transmission between FPGAs via the optical backplane.

  19. 14 CFR 25.1701 - Definition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...

  20. 14 CFR 25.1701 - Definition.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... on electrical devices, including those on relays, interrupters, switches, contactors, terminal blocks and circuit breakers, and other circuit protection devices. (4) Connectors, including feed-through... connections. (7) Electrical splices. (8) Materials used to provide additional protection for wires, including...

  1. Current conducting end plate of fuel cell assembly

    DOEpatents

    Walsh, Michael M.

    1999-01-01

    A fuel cell assembly has a current conducting end plate with a conductive body formed integrally with isolating material. The conductive body has a first surface, a second surface opposite the first surface, and an electrical connector. The first surface has an exposed portion for conducting current between a working section of the fuel cell assembly and the electrical connector. The isolating material is positioned on at least a portion of the second surface. The conductive body can have support passage(s) extending therethrough for receiving structural member(s) of the fuel cell assembly. Isolating material can electrically isolate the conductive body from the structural member(s). The conductive body can have service passage(s) extending therethrough for servicing one or more fluids for the fuel cell assembly. Isolating material can chemically isolate the one or more fluids from the conductive body. The isolating material can also electrically isolate the conductive body from the one or more fluids.

  2. Test probe for surface mounted leadless chip carrier

    DOEpatents

    Meyer, Kerry L.; Topolewski, John

    1989-05-23

    A test probe for a surface mounted leadless chip carrier is disclosed. The probed includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe.

  3. Test probe for surface mounted leadless chip carrier

    DOEpatents

    Meyer, K.L.; Topolewski, J.

    1987-10-02

    A test probe for a surface mounted leadless chip carrier is disclosed. The probe includes specially designed connector pins which allow size reductions in the probe. A thermoplastic housing provides spring action to ensure good mechanical and electrical contact between the pins and the contact strips of a leadless chip carrier. Other features include flexible wires molded into the housing and two different types of pins alternately placed in the housing. These features allow fabrication of a smaller and simpler test probe. 1 fig.

  4. Behavior of Tilted Angle Shear Connectors

    PubMed Central

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N. H.

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type. PMID:26642193

  5. Behavior of Tilted Angle Shear Connectors.

    PubMed

    Khorramian, Koosha; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N H

    2015-01-01

    According to recent researches, angle shear connectors are appropriate to transfer longitudinal shear forces across the steel-concrete interface. Angle steel profile has been used in different positions as L-shaped or C-shaped shear connectors. The application of angle shear connectors in tilted positions is of interest in this study. This study investigates the behaviour of tilted-shaped angle shear connectors under monotonic loading using experimental push out tests. Eight push-out specimens are tested to investigate the effects of different angle parameters on the ultimate load capacity of connectors. Two different tilted angles of 112.5 and 135 degrees between the angle leg and steel beam are considered. In addition, angle sizes and lengths are varied. Two different failure modes were observed consisting of concrete crushing-splitting and connector fracture. By increasing the size of connector, the maximum load increased for most cases. In general, the 135 degrees tilted angle shear connectors have a higher strength and stiffness than the 112.5 degrees type.

  6. KSC-08pd0004

    NASA Image and Video Library

    2008-01-04

    KENNEDY SPACE CENTER, FLA. -- At a lab at NASA's Kennedy Space Center, aerospace technicians with the United Launch Alliance inspect an electrical wiring harness that has been inserted into a replacement feed-through connector during preparations to solder the pins to the socket of the connector that will be installed in the external fuel tank for space shuttle Atlantis' STS-122 mission. The technicians performed this exacting task on the Centaur upper stage for Atlas and Titan launches in 1994 and were specifically chosen for the task. Soldering the connector pins and sockets together addresses the most likely cause of a problem in the engine cutoff sensor system, or ECO system. Some of the tank's ECO sensors failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the soldering is completed and the connector is reinstalled, shuttle program managers will decide on how to proceed. The launch date for mission STS-122 is under review. Photo credit: NASA/Kim Shiflett

  7. Spacelab payload accommodation handbook. Appendix A: Avionics interface definition

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Spacelab side of the electrical interface between Spacelab subsystem equipment and experiments is presented. The electrical hardware which interfaces with the experiments is defined and the signal/load characteristics are stated. Major subsystems considered include: electrical power and distribution; command and data management subsystem; orbiter avionics via dedicated connectors of Spacelab; and electrical ground support equipment.

  8. Electrical continuity scanner facilitates identification of wires for soldering to connectors

    NASA Technical Reports Server (NTRS)

    Boulton, H. C.; Diclemente, R. A.

    1966-01-01

    Electrical continuity scanner automatically scans 50 wires in 2 seconds to correlate all wires in a circuit with their respective known ends. Modifications made to the basic plan provide circuitry for scanning up to 250 wires.

  9. Smart material joint band

    NASA Astrophysics Data System (ADS)

    Tucchio, Michael A.; Stoodt, Robert A.; Livsey, Robert A.

    1994-11-01

    The present invention relates to an improved connector for joining two tubular members together. The connector is formed by a plurality of longitudinally extending fingers extending from an end of one of tubular members and at least one locking groove in the other of the tubular members for receiving the fingers. The connector further includes a circumferentially extending wire member which is received in a notch in a head portion of each of the plurality of fingers. The wire member is preferably formed from a shape memory alloy and has an original circumference less than the circumference of a circle formed by the notches in a head portions of the fingers. The connector includes apertures through which electric wires may be connected to the shape memory alloy ring member so as to cause the shape memory alloy ring member to return to its original shape and allow release of the joint connection.

  10. Smart material joint band

    NASA Astrophysics Data System (ADS)

    Tucchio, Michael A.; Stoodt, Robert A.; Livsey, Robert A.

    1993-12-01

    The present invention relates to an improved connector for joining two tubular members together. The connector is formed by a plurality of longitudinally extending fingers extending from an end of one of the tubular members and at least one locking groove in the other of the tubular members for receiving the fingers. The connector further includes a circumferentially extending wire member which is received in a notch in a head portion of each of the plurality of fingers. The wire member is preferably formed from a shape memory alloy and has an original circumference less than the circumference of a circle formed by the notches in the head portions of the fingers. The connector includes apertures through which electric wires may be connected to the shape memory alloy ring member so as to cause the shape memory alloy ring member to return to its original shape and allow release of the joint connection.

  11. Lunar Dust-Tolerant Electrical Connector

    NASA Technical Reports Server (NTRS)

    Herman, Jason; Sadick, Shazad; Roberts, Dustyn

    2010-01-01

    An electrical connector was developed that is tolerant of the presence of lunar dust. Novel features of the connector include the use of a permeable membrane to act both as a dust barrier and as a wiper to limit the amount of dust that makes its way into the internal chamber of the connector. The development focused on the Constellation lunar extravehicular activity (EVA) spacesuit s portable life support system (PLSS) battery recharge connector; however, continued research is applying this technology to other lunar surface systems such as lunar rover subsystems and cryogenic fluid transfer connections for in-situ resource utilization (ISRU) applications. Lunar dust has been identified as a significant and present challenge in future exploration missions. In addition to posing contamination and health risks for human explorers, the interlocking, angular nature of lunar dust and its broad grain size distribution make it particularly harmful to mechanisms with which it may come into contact. All Apollo lunar missions experienced some degree of equipment failure because of dust, and it appears that dust accumulation on exposed material is unavoidable and difficult to reverse. Both human EVA and ISRU activities are on the mission horizon and are paramount to the establishment of a permanent human base on the Moon. Reusable and dust-tolerant connection mechanisms are a critical component for mission success. The need for dust-tolerant solutions is also seen in utility work and repair, mass transit applications, construction, mining, arctic and marine environments, diving (search and rescue), and various operations in deserts, where dust or sand clogging and coating different mechanisms and connections may render them difficult to operate or entirely inoperable.

  12. High thermal conductivity connector having high electrical isolation

    DOEpatents

    Nieman, Ralph C.; Gonczy, John D.; Nicol, Thomas H.

    1995-01-01

    A method and article for providing a low-thermal-resistance, high-electrical-isolation heat intercept connection. The connection method involves clamping, by thermal interference fit, an electrically isolating cylinder between an outer metallic ring and an inner metallic disk. The connection provides durable coupling of a heat sink and a heat source.

  13. Multi-fibers connectors systems for FOCCoS-PFS-Subaru

    NASA Astrophysics Data System (ADS)

    de Oliveira, Antonio Cesar; de Oliveira, Ligia Souza; Souza Marrara, Lucas; dos Santos, Leandro Henrique; Vital de Arruda, Marcio; dos Santos, Jesulino Bispo; Ferreira, Décio; Rosa, Josimar Aparecido; de Paiva Vilaça, Rodrigo; Sodré, Laerte; de Oliveira, Claudia Mendes; Gunn, James E.

    2014-07-01

    The Fiber Optical Cable and Connector System (FOCCoS), provides optical connection between 2400 positioners and a set of spectrographs through optical fibers cables as part of PFS instrument for Subaru telescope. The optical fiber cable will be segmented in 3 parts along the route, cable A, cable B and cable C, connected by a set of multi-fiber connectors. The company USCONEC produces the multi-fiber connector under study. The USCONEC 32F model can connect 32 optical fibers in a 4 x 8 matrix arrangement. The ferrules are made of a durable composite, Polyphenylene Sulfide (PPS) based thermoplastic. The connections are held in place by a push-on/pull-off latch, and the connector can also be distinguished by a pair of metal guide pins that protrude from the front of the connector. Two fibers per connector will be used for monitoring the connection procedure. It was found to be easy to polish and it is small enough to be mounted in groups. Highly multiplexed instruments like PFS require a fiber connector system that can deliver excellent optical performance and reliability. PFS requires two different types of structures to organize the connectors. The Tower Connector system, with 80 multi-fiber connectors, will be a group of connectors for connecting cable B (Telescope Structure) with cable C (Positioners Plate). The Gang Connector system is a group of 8 gang connectors, each one with 12 multi-fibers connectors, for connecting cable B (Telescope Structure) with cable A (Spectrograph). The bench tests with these connector systems and the chosen fibers should measure the throughput of light and the stability after many connections and disconnections. In this paper we describe tests and procedures to evaluate the throughput and FRD increment. The lifetime of the ferrules is also in evaluation.

  14. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    NASA Technical Reports Server (NTRS)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  15. Continuity tester screens out faulty socket connections

    NASA Technical Reports Server (NTRS)

    Golding, G.

    1964-01-01

    A device, used before and after assembly, tests the continuity of an electrical circuit through each pin and socket of multiple connector sockets. Electrically insulated except at the contact area, a test probe is dimensioned to make contact only in properly formed sockets.

  16. MIL-L-87177 and CLT:X-10 Lubricants Improve Electrical Connector Fretting Corrosion Behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AUKLAND,NEIL R.; HANLON,JAMES T.

    1999-10-12

    We have conducted a fretting research project using MIL-L-87177 and CLT: X-10 lubricants on Nano-miniature connectors. When they were fretted without lubricant, individual connectors first exceeded our 0.5 ohm failure criteria from 2,341 to 45,238 fretting cycles. With additional fretting, their contact resistance increased to more than 100,000 ohms. Unmodified MIL-L-87177 lubricant delayed the onset of first failure to between 430,000 and over 20,000,000 fretting cycles. MIL-L-87177 modified by addition of Teflon powder delayed first failure to beyond 5 million fretting cycles. Best results were obtained when Teflon was used and also when both the straight and modified lubricants weremore » poured into and then out of the connector. CLT: X-10 lubricant delayed the onset of first failure to beyond 55 million cycles in one test where a failure was actually observed and to beyond 20 million cycles in another that was terminated without failure. CLT: X-10 recovered an unlubricated connector driven deeply into failure, with six failed pins recovering immediately and four more recovering during an additional 420 thousand fretting cycles. MIL-L-87177 was not able to recover a connector under similar conditions.« less

  17. 5 CFR 532.313 - Private sector industries.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... electrical signals. 335311 Power, distribution, and specialty transformer manufacturing. 48531 Taxi service... Electronic coil, transformer, and other inductor manufacturing. 334417 Electronic connector manufacturing...

  18. Photonic-powered cable assembly

    DOEpatents

    Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.

    2013-01-22

    A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

  19. Photonic-powered cable assembly

    DOEpatents

    Sanderson, Stephen N; Appel, Titus James; Wrye, IV, Walter C

    2014-06-24

    A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

  20. 77 FR 36146 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-18

    ... airplanes to the applicability. We are issuing this AD to prevent degradation of the electrical insulation... could cause the level sensor to heat above acceptable limits, possibly resulting in a fuel tank... connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation sleeves of the...

  1. 76 FR 68671 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-07

    ... incorrect connector sleeves materials fitted to the MTI units. Degradation of the electrical insulation... condition, if not corrected, could cause the level sensor to heat above acceptable limits, possibly.... Degradation of the electrical insulation sleeves of the Low- level indication lamps on the MTI of the flight...

  2. Decreasing the time to defibrillation: a comparative study of defibrillator electrode designs.

    PubMed

    Adams, Bruce D; Easty, David M; Stuffel, Elaine; Hartman, Irma

    2005-08-01

    Time to defibrillation (T(defib)) is the most important modifiable factor affecting survival from cardiac arrest. Mortality increases by approximately 7--10% for each minute of defibrillation delay. The purpose of this study was to determine whether defibrillator electrode design complexity affects T(defib). This was a randomized sequential design study utilizing a standardized ventricular fibrillation cardiac arrest model for CPR mannequins. We evaluated two common types of defibrillator electrode models: a single connector design and a double connector design that requires an adaptor. We compared the time required by cardiac arrest team leaders to apply the two types of defibrillator electrodes to a manikin, connect them to a defibrillator, and then deliver a first defibrillatory shock. The primary outcome was time to defibrillation. The secondary outcome was difficulty of application as perceived by the physician participants on a 10 cm visual analog scale. Thirty-two residents performed a sequential assessment of both electrodes. The average T(defib) for the double connector model was 42.9s longer than that of the single connector model (87.5s versus 44.6s, p<0.001). As evaluated by the study participants, the single connector model was significantly easier to apply then the double connector model (1.3 cm versus 4.4 cm, p<0.001). The single connector defibrillator electrode design was associated with a significantly shorter T(defib) than the double connector design. It also was judged to be easier to apply in this model. Ergonomic design of defibrillator electrodes can significantly impact time to defibrillation.

  3. KSC-08pd0001

    NASA Image and Video Library

    2008-01-04

    KENNEDY SPACE CENTER, FLA. -- At a lab at NASA's Kennedy Space Center, a Lockheed Martin technician prepares an electrical wiring harness during a procedure to solder the pins to the socket of the replacement feed-through connector that will be installed in the external fuel tank for space shuttle Atlantis' STS-122 mission. Two United Launch Alliance technicians, who performed this exacting task on the Centaur upper stage for Atlas and Titan launches in 1994, will be doing the soldering. Soldering the connector pins and sockets together addresses the most likely cause of a problem in the engine cutoff sensor system, or ECO system. Some of the tank's ECO sensors failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the soldering is completed and the connector is reinstalled, shuttle program managers will decide on how to proceed. The launch date for mission STS-122 is under review. Photo credit: NASA/Kim Shiflett

  4. TJC: plan and prepare for the transition to new tubing connectors to minimize the risk of dangerous misconnections, clinician frustration.

    PubMed

    2014-12-01

    To reduce the risk of dangerous tubing misconnections, the ISO is rolling out new tubing connector standards that will eventually make it nearly impossible for tubing associated with one delivery system to be connected to a delivery system that serves a different purpose. Experts welcome the change, noting that tubing misconnections that cause injury and even death have been happening for years. However, TJC has issued a Sentinel Event Alert, warning that health care organizations need to be vigilant in managing the risk posed by these misconnections during the phased-in transition to the new connectors. Experts explain that tubing misconnections occur because many different types of tubing utilize the same Leur connector, making it possible for a clinician to mistakenly connect a tube to the wrong delivery system. The most common type of tubing misconnection reported to the ISMP is when a clinician wants to administer something to a patient through a feeding tube, but accidently administers the substance through an IV tube instead. The first new connector, called the ENFit, is going to be for enteral feeding tubes. It will not connect to IV tubing, making that type of misconnection unlikely. The new connector should be available early next year. Since hospitals will continue to use older tubing until their supplies are exhausted, manufacturers will temporarily provide adapters capable of making new administration sets compatible with older tubing.

  5. Self-Aligning Mechanical And Electrical Coupling

    NASA Technical Reports Server (NTRS)

    Vranish, John M.

    1993-01-01

    Two mating assemblies of mechanical and electrical coupling designed to align itself and so easy to use that robot can operate it. Rollers and v-grooves enforce required alignment when upper and lower assemblies brought into firm contact. Mechanism inside lower assembly provides spring preload between two assemblies plus mating of electrical connectors, all actuated by rotation of driver engaged with bolt via splines.

  6. Kuipers during photo documentation of the fluid and electrical interfaces on the UIA

    NASA Image and Video Library

    2012-01-27

    ISS030-E-156468 (27 Jan. 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, is pictured in the Quest airlock of the International Space Station during photo documentation of the fluid and electrical interfaces on the Umbilical Interface Assembly (UIA) Connector Shelf.

  7. 77 FR 34872 - Airworthiness Directives; Fokker Services B.V. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-12

    ... require modifying galley power supply wiring by disconnecting it from the affected plug/receptacle and reconnecting the power supply wiring through splices. We are proposing this AD to prevent a high electrical load which may lead to overheating of the galley power supply wiring and/or the electrical connector...

  8. 77 FR 37775 - Airworthiness Directives; BAE Systems (Operations) Limited Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ... squib electrical connectors can be cross- connected. This AD requires a general visual inspection of... extinguishing agent being discharged into a wrong compartment and consequent damage to the airplane. DATES: This... bottles of certain BAe 146 and AVRO 146-RJ aeroplanes can be misassembled such that two squib electrical...

  9. Vibration Performance Comparison Study on Current Fiber Optic Connector Technologies

    NASA Technical Reports Server (NTRS)

    Ott, Melanie N.; Thomes Jr., William J.; LaRocca, Frank V.; Switzer, Robert C.; Chuska, Rick F.; Macmurphy, Shawn L.

    2008-01-01

    Fiber optic cables are increasingly being used in harsh environments where they are subjected to vibration. Understanding the degradation in performance under these conditions is essential for integration of the fibers into the given application. System constraints oftentimes require fiber optic connectors so subsystems can be removed or assembled as needed. In the present work, various types of fiber optic connectors were monitored in-situ during vibration testing to examine the transient change in optical transmission and the steady-state variation following the event. Inspection of the fiber endfaces and connectors was performed at chosen intervals throughout the testing.

  10. Socket with built-in valves for the interconnection of microfluidic chips to macro constituents.

    PubMed

    Yang, Zhen; Maeda, Ryutaro

    2003-09-26

    This paper reports a prototype for a standard connector between a microfluidic chip and the macro world. This prototype demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data signals and energy supply. It supports up to 10 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. The socket has built-in valves for each flow channel. It also contains 28 pins for the connection of electrical signals and power. Built-in valves make it possible to control the flow in each channel independently. A chip ( 11.0 x 11.0 x 0.9 mm) can be mounted into or dismounted from the socket with one touch. The fluidic connectors of the socket are designed to contact vertically on the top of chip. And the electrical connectors (the spring array) of that physically support the chip and contact lead pads at the bottom of chip. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.

  11. Replaceable filters and cones for flared-tubing connectors

    NASA Technical Reports Server (NTRS)

    Grant, L. E.; Howland, B. T.

    1970-01-01

    Connector is modified by machining the cone from one end before the fitting is bored to accommodate a metallic-filament type of slip-in filter. Thus, when surface of the cone is damaged, only the cone needs replacement.

  12. Rugged microelectronic module package supports circuitry on heat sink

    NASA Technical Reports Server (NTRS)

    Johnson, A. L.

    1966-01-01

    Rugged module package for thin film hybrid microcircuits incorporated a rigid, thermally conductive support structure, which serves as a heat sink, and a lead wire block in which T-shaped electrical connectors are potted. It protects the circuitry from shock and vibration loads, dissipates internal heat, and simplifies electrical connections between adjacent modules.

  13. Electronic inverter assembly with an integral snubber capacitor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Brij N.; Schmit, Christopher J.

    A coaxial bus connector has a first end and a second end opposite the first end. The first end has a first positive terminal and a first negative terminal coupled to a primary direct current bus of a primary inverter. The second end has a second positive terminal and a second negative terminal coupled to the secondary direct current bus of a secondary inverter, wherein the coaxial bus connector comprises a dielectric material between a center conductor and a coaxial sleeve to form a snubber capacitor to absorb electrical energy or to absorb voltage spikes.

  14. Shields for protecting cables from the effects of electromagnetic noise and interference

    NASA Astrophysics Data System (ADS)

    Hoeft, L. O.; Hofstra, J. S.; Karaskiewicz, R. J.; Torres, B. W.

    1988-12-01

    The intrinsic electromagnetic property of a cable or connector shield is its surface transfer impedance. This is the ratio of the longitudinal open circuit voltage measured on one side of the shield (normally the inside) to the axial current on the other side (normally the outside). In cases where a high electric field is present at the surface of the shield, the transfer admittance or charge transfer elastance is also important. Measurements of typical cables, connectors, backshells and cable terminations are presented and explained in terms of simple models.

  15. STUDY OF THE RHIC BPM SMA CONNECTOR FAILURE PROBLEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LIAW,C.; SIKORA, R.; SCHROEDER, R.

    2007-06-25

    About 730 BPMs are mounted on the RHIC CQS and Triplet super-conducting magnets. Semi-rigid coaxial cables are used to bring the electrical signal from the BPM feedthroughs to the outside flanges. at the ambient temperature. Every year around 10 cables will lose their signals during the operation. The connection usually failed at the warm end of the cable. The problems were either the solder joint failed or the center conductor retracted out of the SMA connector. Finite element analyses were performed to understand the failure mechanism of the solder joint. The results showed that (1) The SMA center conductor canmore » separate from the mating connector due to the thermal retraction. (2) The maximum thermal stress at the warm end solder joint can exceed the material strength of the Pb37/Sn63 solder material and (3) The magnet ramping frequency (-10 Hz), during the machine startup, can possibly resonant the coaxial cable and damage the solder joints, especially when a fracture is initiated. Test results confirmed that by using the silver bearing solder material (a higher strength material) and by crimping the cable at the locations close to the SMA connector (to prevent the center conductor from retracting) can effectively resolve the connector failure problem.« less

  16. Quick-release connector module

    NASA Technical Reports Server (NTRS)

    Sedig, Albert R. (Inventor)

    1995-01-01

    A multi-bay electrical connector is described, of the type that has a frame (12, FIG. 2 ) with cavities (14) that each holds a separate module 20, which enables quick withdrawal of a single module from the frame and its quick replacement. A lock arm (42) is slidable along a first side (50) of a first cavity, and has at least one lock lug (80). A first module has a barrier part (70) that lies inward of the lock lug, which prevents outward movement of the first module out of the frame cavity. The lock arm can be moved to an unlocked position wherein the barrier part on the module lies inward of a gap (84) in the lock arm to permit the module to be pulled out of the frame cavity and later inserted therein. A latch (54) is slidable on the frame in directions (A, B) perpendicular to the sliding movement of the lock arm, and has an abutment (112, FIG. 5 ) that abuts a shoulder (114) on the lock arm to keep the lock arm in its unlocked position until the latch is released.

  17. Development of a Novel Wireless Electric Power Transfer System for Space Applications

    NASA Technical Reports Server (NTRS)

    VazquezRamos, Gabriel; Yuan, Jiann-Shiun

    2011-01-01

    This paper will introduce a new implementation for wireless electric power transfer systems: space applications. Due to the risks that constitute the use of electrical connector for some space missions/applications, a simple wireless power system design approach will be evaluated as an alternative for the use of electrical connectors. This approach takes into consideration the overall system performance by designing the magnetic resonance elements and by verifying the overall system electrical behavior. System characterization is accomplished by executing circuit and analytical simulations using Matlab(TradeMark) and LTSpiceIV(TradeMark) software packages. The design methodology was validated by two different experiments: frequency consideration (design of three magnetic elements) and a small scale proof-ofconcept prototype. Experiment results shows successful wireless power transfer for all the cases studied. The proof-of-concept prototype provided approx.4 W of wireless power to the load (light bulb) at a separation of 3 cm from the source. In addition. a resonant circuit was designed and installed to the battery terminals of a handheld radio without batteries, making it tum on at a separation of approx.5 cm or less from the source. It was also demonstrated by prototype experimentation that multiple loads can be powered wirelessly at the same time with a single electric power source.

  18. Dust-tolerant electrical connector

    NASA Technical Reports Server (NTRS)

    Sadick, Shazad (Inventor); Herman, Jason (Inventor); Roberts, Dustyn (Inventor)

    2011-01-01

    A connector assembly includes releasably mateable plug and receptacle units. At least one socket is enclosed within the receptacle unit and is aligned with at least one permeable membrane disposed in the front end of the receptacle unit. The plug unit includes a body slidably mounted within a longitudinal bore therein. At least one pin extends from the front end of the body and is aligned with at least one permeable membrane disposed in the front end of the plug unit. The plug unit is biased toward a first, de-mate position in which the body is extended rearwardly such that the pin is enclosed with the plug unit and is slidable to a second, mate position in which the body is compressed forwardly such that the pin projects through the permeable membranes of the plug and receptacle units to electrically connect with the socket.

  19. Optimum design of Geodesic dome’s jointing system

    NASA Astrophysics Data System (ADS)

    Tran, Huy. T.

    2018-04-01

    This study attempts to create a new design for joint connector of Geodesic dome. A new type of joint connector design is proposed for flexible rotating connection; comparing it to another, this design is cheaper and workable. After calculating the bearing capacity of the sample according to EC3 and Vietnam standard TCVN 5575-2012, FEM model of the design sample is carried out in many specific situation to consider the stress distribution, the deformation, the local destruction… in the connector. The analytical results and the FE data are consistent. The FE analysis also points out the behavior of some details that simple calculation cannot show. Hence, we can choose the optimum design of joint connector.

  20. Study of electrode slice forming of bicycle dynamo hub power connector

    NASA Astrophysics Data System (ADS)

    Chen, Dyi-Cheng; Jao, Chih-Hsuan

    2013-12-01

    Taiwan's bicycle industry has been an international reputation as bicycle kingdom, but the problem in the world makes global warming green energy rise, the development of electrode slice of hub dynamo and power output connector to bring new hope to bike industry. In this study connector power output to gather public opinion related to patent, basis of collected documents as basis for design, structural components in least drawn to power output with simple connector. Power output of this study objectives connector hope at least cost, structure strongest, highest efficiency in output performance characteristics such as use of computer-aided drawing software Solid works to establish power output connector parts of 3D model, the overall portfolio should be considered part types including assembly ideas, weather resistance, water resistance, corrosion resistance to vibration and power flow stability. Moreover the 3D model import computer-aided finite element analysis software simulation of expected the power output of the connector parts manufacturing process. A series of simulation analyses, in which the variables relied on first stage and second stage forming, were run to examine the effective stress, effective strain, press speed, and die radial load distribution when forming electrode slice of bicycle dynamo hub.

  1. SiC Multi-Chip Power Modules as Power-System Building Blocks

    NASA Technical Reports Server (NTRS)

    Lostetter, Alexander; Franks, Steven

    2007-01-01

    The term "SiC MCPMs" (wherein "MCPM" signifies "multi-chip power module") denotes electronic power-supply modules containing multiple silicon carbide power devices and silicon-on-insulator (SOI) control integrated-circuit chips. SiC MCPMs are being developed as building blocks of advanced expandable, reconfigurable, fault-tolerant power-supply systems. Exploiting the ability of SiC semiconductor devices to operate at temperatures, breakdown voltages, and current densities significantly greater than those of conventional Si devices, the designs of SiC MCPMs and of systems comprising multiple SiC MCPMs are expected to afford a greater degree of miniaturization through stacking of modules with reduced requirements for heat sinking. Moreover, the higher-temperature capabilities of SiC MCPMs could enable operation in environments hotter than Si-based power systems can withstand. The stacked SiC MCPMs in a given system can be electrically connected in series, parallel, or a series/parallel combination to increase the overall power-handling capability of the system. In addition to power connections, the modules have communication connections. The SOI controllers in the modules communicate with each other as nodes of a decentralized control network, in which no single controller exerts overall command of the system. Control functions effected via the network include synchronization of switching of power devices and rapid reconfiguration of power connections to enable the power system to continue to supply power to a load in the event of failure of one of the modules. In addition to serving as building blocks of reliable power-supply systems, SiC MCPMs could be augmented with external control circuitry to make them perform additional power-handling functions as needed for specific applications: typical functions could include regulating voltages, storing energy, and driving motors. Because identical SiC MCPM building blocks could be utilized in a variety of ways, the cost and difficulty of designing new, highly reliable power systems would be reduced considerably. Several prototype DC-to-DC power-converter modules containing SiC power-switching devices were designed and built to demonstrate the feasibility of the SiC MCPM concept. In anticipation of a future need for operation at high temperature, the circuitry in the modules includes high-temperature inductors and capacitors. These modules were designed to be stacked to construct a system of four modules electrically connected in series and/or parallel. The packaging of the modules is designed to satisfy requirements for series and parallel interconnection among modules, high power density, high thermal efficiency, small size, and light weight. Each module includes four output power connectors two for serial and two for parallel output power connections among the modules. Each module also includes two signal connectors, electrically isolated from the power connectors, that afford four zones for signal interconnections among the SOI controllers. Finally, each module includes two input power connectors, through which it receives power from an in-line power bus. This design feature is included in anticipation of a custom-designed power bus incorporating sockets compatible with snap-on type connectors to enable rapid replacement of failed modules.

  2. Design and Optimization of Slot Aluminum Alloy Connectors of Photovoltaics Applied to High-rise Building Facades

    NASA Astrophysics Data System (ADS)

    Liang, Ya-Wei; Zhang, Hong-Mei; Dong, Jin-Zhi; Shi, Zhen-Hua

    2016-05-01

    Building Integrated Photovoltaic (BIPV) is a resort to save energy and reduce heat gain of buildings, utilize new and renewable energy, solve environment problems and alleviate electricity shortage in large cities. The area needed to generate power makes facade integrated photovoltaic panel a superb choice, especially in high-rise buildings. Numerous scholars have hitherto explored Building Facade Integrated Photovoltaic, however, focusing mainly on thermal performance, which fails to ensure seismic safety of high-rise buildings integrated photovoltaic. Based on connecting forms of the glass curtain wall, a connector jointing photovoltaic panel and facade was designed, which underwent loading position and size optimization. Static loading scenarios were conducted to test and verify the connector's mechanical properties under gravity and wind loading by means of HyperWorks. Compared to the unoptimized design, the optimized one saved material and managed to reduce maximum deflection by 74.64%.

  3. Investigation of injection molding of orthogonal fluidic connector for microfluidic devices

    NASA Astrophysics Data System (ADS)

    Xu, Zheng; Cao, Dong; Zhao, Wei; Song, Man-cang; Liu, Jun-shan

    2017-02-01

    Orthogonal fluidic connections are essential for developing multilayered microfluidic devices. At present, most orthogonal connectors are realized by a horizontal channel and a vertical channel in different plates. Therefore, some extra alignment and adhesion processes for precise plate assembly are required. In this paper, the method of injection molding is proposed to make a one-body-type orthogonal connector in a single plastic plate. The connector was composed of a cantilevered tube and the other in the substrate. An injection mold was developed in which a side core-pulling mechanism and an ejection mechanism of push-pipes were combined to form the mold for an orthogonal connector. Both the type and the location of gate were optimized for the mold. The results showed that the fan gate in the middle position of the plate was the most suitable in term of both defect control and practicability. The effect of melt temperature was numerically investigated and then verified experimentally. With the optimized parameters, the relative length and the relative wall thickness of a cantilevered tube in the plastic part can reach 98.89% and 99.80%, respectively. Furthermore, using the plastic part as a cover plate, a three-layer plastic microfluidic device was conveniently fabricated for electrochemical detection.

  4. Miniature, shielded electrical connector with strain relief

    NASA Technical Reports Server (NTRS)

    Diep, Chuong H. (Inventor)

    2006-01-01

    An electrical connector assembly includes a wire bundle having at least one wire with a metal shield surrounding at least a portion of the wire. The shield has an end portion and provides electromagnetic interference protection to the wire. A backshell includes a body and a cover secured to the body together defining an internal cavity with the wire at least partially arranged within the cavity. The backshell provides EMI protection for the portion of the wire bundle not covered by the shield. The backshell includes a hole in a wall of either the body or the cover with the end portion of the shield extending through the hole. The clamp is secured about the body and the cover with the end portion of the shield arranged between the clamp and the backshell grounding the shield to the backshell. The clamp forces the backshell into engagement with the wire bundle to provide strain relief for the wire bundle.

  5. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, H.D.

    1992-09-15

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body. 5 figs.

  6. Rotary union for use with ultrasonic thickness measuring probe

    DOEpatents

    Nachbar, Henry D.

    1992-01-01

    A rotary union for rotatably supporting an ultrasonic probe operable to nondestructively measure the thickness of steam generator tubes to determine the amount of corrosion experienced by the tubes includes a stationary body having a bore therethrough and an outlet drain, and a fitting rotatably mounted within the upper end of the body. The fitting has a bore aligned with the bore of the body. An electrical cable positioned within a water supply tube in an annular arrangement passes through the bore of the body and the bore of the fitting. This annular arrangement, in turn, is positioned within a connector element which extends outwardly from the fitting bore and is connected to the ultrasonic probe. An elastomeric lower bushing seals the annular arrangement to the lower end of the rotary union body and an elastomeric upper bushing seals the connector element to the fitting to permit the connector element and the ultrasonic probe connected thereto to rotate with the fitting relative to the body. The lower and upper bushings permit water to be passed through the annular arrangement and into the ultrasonic probe and thereafter discharged between the annular arrangement and the connector element to the outlet drain of the rotary union body.

  7. Testing methods and techniques: Testing electrical and electronic devices: A compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.

  8. Evaluation of Small Form Factor Fiber Optic Interconnects for the NASA Electronics Parts and Packaging Program (NEPP)

    NASA Technical Reports Server (NTRS)

    Ott, Melanie; Thomes, W. Joe; Blair, Diana; Chuska, Rick; Switzer, Rob

    2010-01-01

    The Diamond AVIM optical fiber connector has been used for over a decade in flight environments. AVIM which stands for Aviation Intermediate Maintenance is always referenced as a fiber optic connector type from the DIN (Deutsches Institut fur Normung) family of optical fiber connectors. The newly available Mini AVIM and DMI (Definition Multimedia Interface) connectors also by Diamond provide similar features as the high performance AVIM with the added benefits of being small form factor for board mount and internal box use where long connectors and strain relief can not be accommodated. Transceiver, fiber laser technology and receiver optic technology based on small sized constraints will benefit the most by the reduction in connector form factor. It is for this reason that the Mini AVIM is being evaluated for multimode and single mode optical fiber use in both fiber based and cable based packaging configurations. In a fiber based termination, there are no cable materials to bond to the connector. The only bonding that is conducted is the mounting of the fiber with epoxy to the connector ferrules (which are called DMI ferrules). In a cable configuration, the compatibility of the connector subcomponents along with the upjacketing materials of the cable around the fiber needs to be considered carefully for termination fabrication. Cabled terminations will show greater insertion loss and high probability of failures during thermal cycling testing. This is due to the stressing of the combination of materials that each have different Coefficients of Thermal Expansion (CTE's) and that are bonded together to the connector subcomponents. As the materials flex during thermal excursions, forces are applied to the termination and can make the system fail if the grouping of materials (per their CTE's) are not compatible and this includes cable materials, epoxies, ferrule and connector body components. For this evaluation, multimode 100 micron core step index fiber was used for the fiber terminated condition, and single mode SMF-28 upjacketed with W.L. Gore Flexlite was used for the cabled configuration. For background purposes, a comparison is presented here for information purposes between the high performance AVIM connector features and the Mini AVIM small form factor connectors. Basic connector features are described here.

  9. Optimization of Connector Position Offset for Bandwidth Enhancement of a Multimode Optical Fiber Link

    NASA Technical Reports Server (NTRS)

    Rawat, Banmali

    2000-01-01

    The multimode fiber bandwidth enhancement techniques to meet the Gigabit Ethernet standards for local area networks (LAN) of the Kennedy Space Center and other NASA centers have been discussed. Connector with lateral offset coupling between single mode launch fiber cable and the multimode fiber cable has been thoroughly investigated. An optimization of connector position offset for 8 km long optical fiber link at 1300 nm with 9 micrometer diameter single mode fiber (SMF) and 50 micrometer diameter multimode fiber (MMF) coupling has been obtained. The optimization is done in terms of bandwidth, eye-pattern, and bit pattern measurements. It is simpler, is a highly practical approach and is cheaper as no additional cost to manufacture the offset type of connectors is involved.

  10. Device for testing continuity and/or short circuits in a cable

    NASA Technical Reports Server (NTRS)

    Hayhurst, Arthur R. (Inventor)

    1995-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of the cable. The pair of connectors electrically connects the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  11. Four-terminal connector for measuring resistance of a pyrotechnic initiator

    NASA Technical Reports Server (NTRS)

    Robinson, Robert L. (Inventor); Graves, Thomas J. (Inventor); Hoffman, III, William C. (Inventor)

    1989-01-01

    A four-terminal electrical connector device (40) for testing and measuring unknown resistances of initiators (11) used for starting pyrotechnic events aboard a Space Transportation System. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurement taken with the device. Separate and independent voltage sensing (19) and current supply (20) circuits each includes a pair of socket contacts (13-16) for mating engagement with the pins (17,18) of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire (23) of the initiator which is required to be between 0.95 and 1.15 ohms.

  12. SSME Electrical Harness and Cable Development and Evolution

    NASA Technical Reports Server (NTRS)

    Abrams, Russ; Heflin, Johnny; Burns, Bob; Camper, Scott J.; Hill, Arthur J.

    2010-01-01

    The Space Shuttle Main Engine (SSME) electrical harness and cable system consists of the various interconnecting devices necessary for operation of complex rocket engine functions. Thirty seven harnesses incorporate unique connectors, backshell adapters, conductors, insulation, shielding, and physical barriers for a long maintenance-free life while providing the means to satisfy performance requirements and to mitigate adverse environmental influences. The objective of this paper is to provide a description of the SSME electrical harness and cable designs as well as the development history and lessons learned.

  13. Nonlinear Analysis of a Bolted Marine Riser Connector Using NASTRAN Substructuring

    NASA Technical Reports Server (NTRS)

    Fox, G. L.

    1984-01-01

    Results of an investigation of the behavior of a bolted, flange type marine riser connector is reported. The method used to account for the nonlinear effect of connector separation due to bolt preload and axial tension load is described. The automated multilevel substructing capability of COSMIC/NASTRAN was employed at considerable savings in computer run time. Simplified formulas for computer resources, i.e., computer run times for modules SDCOMP, FBS, and MPYAD, as well as disk storage space, are presented. Actual run time data on a VAX-11/780 is compared with the formulas presented.

  14. Answer to the dynamic (fretting effect) and static (oxide) behavior of electric contact surfaces: based on a five-year infrared thermographic study

    NASA Astrophysics Data System (ADS)

    Paez-Leon, Cristobal D.; Patino, Antonio R.; Aguillon, Luis

    1991-03-01

    This paper describes the results of a five-year study carried out in 38 power substations (230, 115, 34.5 and 13.8 Kv), located in the Western power electric system of CADAFE (Venezuela's national Electric Utility). A total of 154 hot spots were found between 1980 and 1982, a time span considered a reliable source of information in connection with methodology, term and results. The distribution of hot spots found during those years was 77, 33 and 44. The reduction of the spot/substation parameter was found to be 4.1, 3.3 and 3.1, respectively. Every item detected could have been the cause of major interruptions, locally and regionally, or even the system's blackout. The methodology used to determine the major concentration of findings and their location on the equipment, followed the sequence of Pareto's Diagram and Ishikawa's Graphic. Based on the results of the study whose results are presented here, a lubricant and compound-aid connector for Al-Al and bimetallic electric connections was formulated, developed, manufactured, tested (at IREQ laboratories) and traded (CONECTECH CAC- 01). To date, the whole process represents 12 years of work. The connector's behavior and reliability are being tested throughout Venezuela's national electric system (responsible for the supply of around 50,000 Gwh/year) with the use of 12 Tons of CONECTECH CAC-01.

  15. Program for improved electrical harness documentation and fabrication

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Computer program provides automated print-out of harness interconnection table and automated cross-check of reciprocal pin/connector assignments, and improves accuracy and reliability of final documented data. Programs and corresponding library tapes are successfully and continuously employed on Nimbus spacecraft programs.

  16. Carbon or graphite foam as a heating element and system thereof

    DOEpatents

    Ott, Ronald D [Knoxville, TN; McMillan, April D [Knoxville, TN; Choudhury, Ashok [Oak Ridge, TN

    2004-05-04

    A temperature regulator includes at least one electrically conductive carbon foam element. The foam element includes at least two locations adapted for receiving electrical connectors thereto for heating a fluid, such as engine oil. A combustion engine includes an engine block and at least one carbon foam element, the foam element extending into the engine block or disposed in thermal contact with at least one engine fluid.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rejent, J.A.; Vianco, P.T.; Woodrum, R.A.

    Aging analyses were performed on solder joints from two radar units: (1) a laboratory, N57 tube-type radar unit and (2) a field-returned, B61-0, tube-type radar unit. The cumulative temperature environments experienced by the units during aging were calculated from the intermetallic compound layer thickness and the mean Pb-rich phase particle size metrics for solder joints in the units, assuming an aging time of 35 years for both radars. Baseline aging metrics were obtained from a laboratory test vehicle assembled at AS/FM and T; the aging kinetics of both metrics were calculated from isothermal aging experiments. The N57 radar unit interconnectmore » board solder joints exhibited very little aging. The eyelet solder joints did show cracking that most likely occurred at the time of assembly. The eyelet, SA1126 connector solder joints, showed some delamination between the Cu pad and underlying laminate. The B61 field-returned radar solder joints showed a nominal degree of aging. Cracking of the eyelet solder joints was observed. The Pb-rich phase particle measurements indicated additional aging of the interconnects as a result of residual stresses. Cracking of the terminal pole connector, pin-to-pin solder joint was observed; but it was not believed to jeopardize the electrical functionality of the interconnect. Extending the stockpile lifetime of the B61 tube-type radar by an additional 20 years would not be impacted by the reliability of the solder joints with respect to further growth of the intermetallic compound layer. Additional coarsening of the Pb-rich phase will increase the joints' sensitivity to thermomechanical fatigue.« less

  18. Flexible gas insulated transmission line having regions of reduced electric field

    DOEpatents

    Cookson, Alan H.; Fischer, William H.; Yoon, Kue H.; Meyer, Jeffry R.

    1983-01-01

    A gas insulated transmission line having radially flexible field control means for reducing the electric field along the periphery of the inner conductor at predetermined locations wherein the support insulators are located. The radially flexible field control means of the invention includes several structural variations of the inner conductor, wherein careful controlling of the length to depth of surface depressions produces regions of reduced electric field. Several embodiments of the invention dispose a flexible connector at the predetermined location along the inner conductor where the surface depressions that control the reduced electric field are located.

  19. Electrical hand tools and techniques: A compilation. [utilization of space technology for tools and adapters

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Space technology utilization for developing tools, adapters, and fixtures and procedures for assembling, installing, and servicing electrical components and equipment are discussed. Some of the items considered are: (1) pivotal screwdriver, (2) termination locator tool for shielded cables, (3) solder application tools, (4) insulation and shield removing tool, and (5) torque wrench adapter for cable connector engaging ring. Diagrams of the various tools and devices are provided.

  20. Feed-through connector couples RF power into vacuum chamber

    NASA Technical Reports Server (NTRS)

    Grandy, G. L.

    1967-01-01

    Feed-through device connects RF power to an RF coil in a vacuum chamber. The coil and leads are water cooled and vacuum tight seals are provided at the junctions. The device incorporates silver soldered copper tubes, polytetrafluoroethylene electrical insulators, and O-ring vacuum seals.

  1. 78 FR 70580 - Amphenol Backplane Systems, Including On-Site Leased Workers From Technical Needs and National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... Systems, Including On-Site Leased Workers From Technical Needs and National Engineering, Nashua, New... to the production of electrical connectors and backplane assemblies. The subject worker group includes on-site leased workers from Technical Needs and National Engineering. Workers of the subject firm...

  2. Swanson during Day 2 of CDRA IFM

    NASA Image and Video Library

    2014-04-09

    ISS039-E-010367 (9 April 2014) --- In the Kibo laboratory aboard the International Space Station, Expedition 39 Flight Engineer Steve Swanson works during in-flight maintenance to mate electrical connectors in Tranquility's Carbon Dioxide Removal Assembly (CDRA). The image was taken during the second day of CDRA in-flight maintenance.

  3. 77 FR 71489 - Airworthiness Directives; GA 8 Airvan (Pty) Ltd Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-03

    ...), Department of Transportation (DOT). ACTION: Final rule. SUMMARY: We are adopting a new airworthiness... burnt electrical connectors leading to the left-hand wingtip pitot heater, which may result in loss of...-140, 1200 New Jersey Avenue SE., Washington, DC 20590. For service information identified in this AD...

  4. Study of Increasing Lead Times in Major Weapon Systems Acquisition.

    DTIC Science & Technology

    1982-07-31

    Conduit Covers X X X Connectors, Electrical X X X X X Control Systems (Auto- mated, Boiler) X Davit, Boat, Power- Opera.ted X Diodes X X X X A iX...tubes. Other end uses include washers in computer equipment, electrical insulators in motors and generators, and retardation plates in lasers . Supply...relays, electron tubes, printed circuits, and resistors. Platinum is also used in dentistry and for jewelry. Supply, A small amount of platinum (less

  5. Engineering study of the module/array interface for large terrestrial photovoltaic arrays

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Three major areas--structural, electrical, and maintenance--were evaluated. Efforts in the structural area included establishing acceptance criteria for materials and members, determining loading criteria, and analyzing glass modules in various framing system configurations. Array support structure design was addressed briefly. Electrical considerations included evaluation of module characteristics, intermodule connectors, array wiring, converters and lightning protection. Plant maintenance features such as array cleaning, failure detection, and module installation and replacement were addressed.

  6. Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production.

    PubMed

    Wada, Junichiro; Hideshima, Masayuki; Inukai, Shusuke; Matsuura, Hiroshi; Wakabayashi, Noriyuki

    2014-01-01

    To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate. © 2015 S. Karger AG, Basel.

  7. An evaluation of the spring finger solder joints on SA1358-10 and SA2052-4 connector assemblies (MC3617,W87).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kilgo, Alice C.; Vianco, Paul Thomas; Hlava, Paul Frank

    2006-08-01

    The SA1358-10 and SA2052-4 circular JT Type plug connectors are used on a number of nuclear weapons and Joint Test Assembly (JTA) systems. Prototype units were evaluated for the following specific defects associated with the 95Sn-5Sb (Sn-Sb, wt.%) solder joint used to attach the beryllium-copper (BeCu) spring fingers to the aluminum (Al) connector shell: (1) extended cracking within the fillet; (2) remelting of the solder joint during the follow-on, soldering step that attached the EMR adapter ring to the connector shell (and/or soldering the EMR shell to the adapter ring) that used the lower melting temperature 63Sn-37Pb (Sn-Pb) alloy; andmore » (3) spalling of the Cd (Cr) layer overplating layer from the fillet surface. Several pedigrees of connectors were evaluated, which represented older fielded units as well as those assemblies that were recently constructed at Kansas City Plant. The solder joints were evaluated that were in place on connectors made with the current soldering process as well as an alternative induction soldering process for attaching the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely the EMR adapter ring to the shell. Very similar observations were made, which crossed the different pedigrees of parts and processes. The extent of cracking in the top side fillets varied between the different connector samples and likely reflected the different extents to which the connector was mated to its counterpart assembly. In all cases, the spring finger solder joints on the SA1358-10 connectors were remelted as a result of the subsequent EMR adapter ring attachment process. Spalling of the Cd (Cr) overplating layer was also observed for these connectors, which was a consequence of the remelting activity. On the other hand, the SA2052-4 connector did not exhibit evidence of remelting of the spring finger solder joint. The Cd (Cr) layer did not show signs of spalling. These results suggested that, due to the size of the SA1358-10 connector, any of the former or current soldering processes used to attach the EMR adapter ring and/or EMR shell to the connector shell, requires a level of heat energy that will always result in the remelting of the spring finger solder joint attached with either the Sn-Ag or the Sn-Sb alloy. Lastly, it was construed that the induction soldering process, which is used to attach the EMR adapter ring onto the shell, was more likely to have caused the remelting event rather than the more localized heat source of the hand soldering iron used to attach the EMR shell to the adapter ring.« less

  8. 75 FR 80068 - Notice of Availability of the Final Environmental Impact Report/Final Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-21

    ... would carry electricity from several renewable energy projects proposed in and around the Ivanpah Valley, including the Ivanpah Solar Energy Generation System currently under construction by BrightSource Energy..., Nevada, which would serve as a connector hub for solar energy generated in the Ivanpah Valley area. The...

  9. Photovoltaic device assembly and method

    DOEpatents

    Keenihan, James R.; Langmaid, Joseph A.; Cleereman, Robert J.; Graham, Andrew T.

    2015-09-29

    The present invention is premised upon a connector device and method that can more easily electrically connect a plurality of PV arrays and/or locate these arrays upon a building or structure. It also can optionally provide some additional components (e.g. a bypass diode and/or an indicator means) and can enhance the serviceability of the array.

  10. Standardization of Alternatives to Cadmium Plating for Electrical and Fiber Optic Connectors (Briefing Charts)

    DTIC Science & Technology

    2012-08-01

    with trivalent conversion coat, was recently added to MIL-DTL-55181 (Note: The corrosion requirement for 55181 is 48 hours (non-dynamic), as...for Class W, OD-Cd with Hexavalent Chromium (Cr6+) top coat Olive-Drab Cadmium finish requirements (Note: Passivation process with a Cr6

  11. Easy-To-Use Connector

    NASA Technical Reports Server (NTRS)

    Wightman, William D.; Gernhardt, Michael

    1993-01-01

    Quick-connect/disconnect mechanism consists of two mating assemblies put together easily, even when initially misaligned by fairly large amounts. Used as electrical- or fluid-connection interface. Operated by humans or robots when fast connections must be made without precise positioning, -- for example, on offshore oil rigs, ship-to-dock links, nuclear facilities, and aircraft at loading gates.

  12. Tool for Inspecting Alignment of Twinaxial Connectors

    NASA Technical Reports Server (NTRS)

    Smith, Christopher R.

    2008-01-01

    A proposed tool would be used to inspect alignments of mating twinaxial-connector assemblies on interconnecting wiring harnesses. More specifically, the tool would be used to inspect the alignment of each contact pin of each connector on one assembly with the corresponding socket in the corresponding connector on the other assembly. It is necessary to inspect the alignment because if mating of the assemblies is attempted when any pin/socket pair is misaligned beyond tolerance, the connection will not be completed and the dielectric material in the socket will be damaged (see Figure 1). Although the basic principle of the tool is applicable to almost any type of mating connector assemblies, the specific geometry of the tool must match the pin-and-socket geometry of the specific mating assemblies to be inspected. In the original application for which the tool was conceived, each of the mating assemblies contains eight twinaxial connectors; the pin diameter is 0.014 in. (.0.35 mm), and the maximum allowable pin/socket misalignment is 0.007 in. (.0.18 mm). Incomplete connections can result in loss of flight data within the functional path to the space shuttle crew cockpit displays. The tool (see Figure 2) would consist mainly of a transparent disk with alignment clocking tabs that can be fitted onto either connector assembly. Sets of circles or equivalent reference markings are affixed to the face of the tool, located at the desired positions of the mating contact pairs. An inspector would simply fit the tool onto a connector assembly, engaging the clocking tabs until the tool fits tightly. The inspector would then align one set of circles positioning a line of sight perpendicular to one contact within the connector assembly. Mis alignments would be evidenced by the tip of a pin contact straying past the inner edge of the circle. Socket contact misalignments would be evidenced by a crescent-shaped portion of the white dielectric appearing within the circle. The tool could include a variable magnifier plus an illuminator that could be configured so as not to cast shadows.

  13. An in vitro comparison of standard cleaning to a continuous passive disinfection cap for the decontamination of needle-free connectors.

    PubMed

    Casey, Anna L; Karpanen, Tarja J; Nightingale, Peter; Elliott, Tom S J

    2018-01-01

    The optimal decontamination method for needle-free connectors is still unresolved. The objective of this study was to determine if a continuous passive disinfection cap is as effective as standard cleaning for the microbial decontamination of injection ports of two types of needle-free connectors. The injection ports of needle-free connectors were inoculated with Staphylococcus aureus and allowed to dry. Disinfection caps containing 70% ( v / v ) isopropyl alcohol (IPA) were attached to the connectors for one, three or 7 days and were compared with needle-free connectors cleaned with 2% ( w / v ) chlorhexidine gluconate (CHG) in 70% ( v/v ) IPA. The number of S. aureus remaining on the injection ports was evaluated. Median log 10 reductions and 95% confidence interval (CI) were calculated and data analyzed using the Mann-Whitney test. The application of the disinfection cap resulted in a significantly higher reduction in S. aureus than the 2% ( w / v ) CHG in 70% ( v / v ) IPA wipe, achieving a > 5 Log 10 reduction in CFU at each time point. The disinfection caps resulted in a significantly higher reduction in S.aureus on the injection ports when compared to the use of a 2% ( w/v ) CHG in 70% ( v/v ) IPA wipe. This offers an explanation for the lower rates of central-line associated bloodstream infection (CLABSI) associated with the use of disinfection caps reported in clinical studies.

  14. High power connection system

    DOEpatents

    Schaefer, Christopher E.; Beer, Robert C.; McCall, Mark D.

    2000-01-01

    A high power connection system adapted for automotive environments which provides environmental and EMI shielding includes a female connector, a male connector, and a panel mount. The female connector includes a female connector base and a snap fitted female connector cover. The male connector includes a male connector base and a snap fitted male connector cover. The female connector base has at least one female power terminal cavity for seatably receiving a respective female power terminal. The male connector base has at least one male power terminal cavity for seatably receiving a respective male power terminal. The female connector is covered by a cover seal and a conductive shroud. A pair of lock arms protrude outward from the front end of the male connector base, pass through the panel mount and interface with a lever of a lever rotatably connected to the shroud to thereby mechanically assist mating of the male and female connectors. Safety terminals in the male and female connectors provide a last-to-connect-first-to-break connection with an HVIL circuit.

  15. Coaxial connector for use with printed circuit board edge connector

    DOEpatents

    Howard, Donald R.; MacGill, Robert A.

    1989-01-01

    A coaxial cable connector for interfacing with an edge connector for a printed circuit board whereby a coaxial cable can be interconnected with a printed circuit board through the edge connector. The coaxial connector includes a body having two leg portions extending from one side for receiving the edge connector therebetween, and a tubular portion extending from an opposing side for receiving a coaxial cable. A cavity within the body receives a lug of the edge connector and the center conductor of the coaxial cable. Adjacent lugs of the edge connector can be bend around the edge connector housing to function as spring-loaded contacts for receiving the coaxial connector. The lugs also function to facilitate shielding of the center conductor where fastened to the edge connector lug.

  16. All Optical Solution for Free Space Optics Point to Point Links

    NASA Astrophysics Data System (ADS)

    Hirayama, Daigo

    Optical network systems are quickly replacing electrical network systems. Optical systems provide better bandwidth, faster data rates, better security to networks, and are less susceptible to noise. Free Space Optics (systems) still rely on numerous electrical systems such as the modulation and demodulation systems to convert optical signals to electrical signals for the transmitting laser. As the concept of the entirely optical network becomes more realizable, the electrical components of the FSO system will become a hindrance to communications. The focus of this thesis is to eliminate the electrical devices for the FSO point to point links by replacing them with optical devices. The concept is similar to an extended beam connector. However, where an extended beam connector deals with a gap of a few millimeters, my focus looks at distances from 100 meters to one kilometer. The aim is to achieve a detectable signal of 1nW at a distance of 500 meters at a wavelength of 1500-1600nm. This leads to application in building to building links and mobile networks. The research examines the design of the system in terms of generating the wave, the properties of the fiber feeding the wave, and the power necessary to achieve a usable distance. The simulation is executed in Code V by Synopsys, which is an industry standard to analyze optical systems. A usable device with a range of around 500m was achieved with an input power of 1mW. The approximations of the phase function resulted in some aberrations to the profile of the beam, but were not very detrimental to the function of the device. The removal of electrical devices from a FSO point to point link decreased the power used to establish the link and decreased the cost.

  17. DEVELOPMENT OF REMOTE HANFORD CONNECTOR GASKET REPLACEMENT TOOLING FOR DWPF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D.; Coughlin, Jeffrey

    2009-05-05

    The Defense Waste Processing Facility (DWPF) requested the Savannah River National Laboratory (SRNL) to develop tooling and equipment to remotely replace gaskets in mechanical Hanford connectors to reduce personnel radiation exposure as compared to the current hands-on method. It is also expected that radiation levels will continually increase with future waste streams. The equipment is operated in the Remote Equipment Decontamination Cell (REDC), which is equipped with compressed air, two master-slave manipulators (MSM's) and an electro-mechanical manipulator (EMM) arm for operation of the remote tools. The REDC does not provide access to electrical power, so the equipment must be manuallymore » or pneumatically operated. The MSM's have a load limit at full extension of ten pounds, which limited the weight of the installation tool. In order to remotely replace Hanford connector gaskets several operations must be performed remotely, these include: removal of the spent gasket and retaining ring (retaining ring is also called snap ring), loading the new snap ring and gasket into the installation tool and installation of the new gasket into the Hanford connector. SRNL developed and tested tools that successfully perform all of the necessary tasks. Removal of snap rings from horizontal and vertical connectors is performed by separate air actuated retaining ring removal tools and is manipulated in the cell by the MSM. In order install a new gasket, the snap ring loader is used to load a new snap ring into a groove in the gasket installation tool. A new gasket is placed on the installation tool and retained by custom springs. An MSM lifts the installation tool and presses the mounted gasket against the connector block. Once the installation tool is in position, the gasket and snap ring are installed onto the connector by pneumatic actuation. All of the tools are located on a custom work table with a pneumatic valve station that directs compressed air to the desired tool and vents the tools as needed. Extensive testing of tooling operation was performed in the DWPF manipulator repair shop. This testing allowed the operators to gain confidence before the equipment was exposed to radioactive contamination. The testing also led to multiple design improvements. On July 17 and 29, 2008 the Remote Gasket Replacement Tooling was successfully demonstrated in the REDC at the DWPF of The Savannah River Site.« less

  18. High voltage cabling for high power spacecraft

    NASA Technical Reports Server (NTRS)

    Dunbar, W. G.

    1981-01-01

    Studies by NASA have shown that many of the space missions proposed for the time period 1980 to 2000 will require large spacecraft structures to be assembled in orbit. Large antennas and power systems up to 2.5 MW size are predicted to supply the electrical/electronic subsystems, solar electric subsystems, solar electric propulsion, and space processing for the near-term programs. Platforms of 100 meters/length for stable foundations, utility stations, and supports for these multi-antenna and electronic powered mechanisms are also being considered. This paper includes the findings of an analytic and conceptual design study for large spacecraft power distribution, and electrical loads and their influence on the cable and connector requirements for these proposed large spacecraft.

  19. Dual contact pogo pin assembly

    DOEpatents

    Hatch, Stephen McGarry

    2015-01-20

    A contact assembly includes a base and a pair of electrical contacts supported by the base. A first end of the first electrical contact corresponds to a first end of the base and is configured to engage a first external conductive circuit element. A first end of the second electrical contact also corresponds to the first end of the base and is configured to engage a second external conductive circuit element. The first contact and the second contact are electrically isolated from one another and configured to compress when engaging an external connector element. The base includes an aperture positioned on a second end of the base outboard of a second end of the first and second electrical contacts. The aperture presents a narrowing shape with a wide mouth distal the electrical contacts and a narrow internal through-hole proximate the electrical contacts.

  20. Dual contact pogo pin assembly

    DOEpatents

    Hatch, Stephen McGarry

    2016-06-21

    A contact assembly includes a base and a pair of electrical contacts supported by the base. A first end of the first electrical contact corresponds to a first end of the base and is configured to engage a first external conductive circuit element. A first end of the second electrical contact also corresponds to the first end of the base and is configured to engage a second external conductive circuit element. The first contact and the second contact are electrically isolated from one another and configured to compress when engaging an external connector element. The base includes an aperture positioned on a second end of the base outboard of a second end of the first and second electrical contacts. The aperture presents a narrowing shape with a wide mouth distal the electrical contacts and a narrow internal through-hole proximate the electrical contacts.

  1. Hybrid Vehicles

    DTIC Science & Technology

    2008-12-08

    chassis) by a ground strap, wire, welded connection or other suitable low-resistance mechanical connection. Case ground connectors routed from other...environment of a hybrid electric vehicle. Alternative temperature measuring transducers, e.g., thermistors , should be considered when thermocouples are...A 3. Is the ground connection to the chassis or frame mechanically secured by one of the following methods? a. Secured to a spot- welded

  2. 75 FR 25288 - Notice of Availability of the Draft Environmental Impact Report and Draft Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... a connector hub for solar energy that may be produced by future solar generation projects in the... authorization to SCE for the proposed EITP project. The EITP would carry electricity from several renewable energy projects proposed in and around the Ivanpah Valley, including the Ivanpah Solar Energy Generation...

  3. Tunnel junction multiple wavelength light-emitting diodes

    DOEpatents

    Olson, Jerry M.; Kurtz, Sarah R.

    1992-01-01

    A multiple wavelength LED having a monolithic cascade cell structure comprising at least two p-n junctions, wherein each of said at least two p-n junctions have substantially different band gaps, and electrical connector means by which said at least two p-n junctions may be collectively energized; and wherein said diode comprises a tunnel junction or interconnect.

  4. 75 FR 22512 - Airworthiness Directives; Piaggio Aero Industries S.p.A. Model PIAGGIO P-180 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-29

    ... Airworthiness Directives; Piaggio Aero Industries S.p.A. Model PIAGGIO P-180 Airplanes AGENCY: Federal Aviation... presence of potential ignition sources such as electrical equipment and connectors. As a consequence, this..., agree with their substance. But we might have found it necessary to use different words from those in...

  5. Effects of ultra-vacuum and space environment on contact ohmic resistance: LDEF experiment AO 138-11

    NASA Technical Reports Server (NTRS)

    Assie, Jean-Pierre; Perotto, Alfred

    1992-01-01

    The FRECOPA experimentation of chemical resistance of electrical connector contacts, as described, has evidenced the detrimental time variations of nickel plated conductors and gilded copper contacts, irrespective of crimping storage or metal peening conditions. With a view to reorient aluminum technology a silvered aluminum conductor/gilded aluminum contact solution was evaluated.

  6. 77 FR 58052 - Airworthiness Directives; GA 8 Airvan (Pty) Ltd Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... adopt a new airworthiness directive (AD) for GA 8 Airvan (Pty) Ltd Models GA8 and GA8-TC320 airplanes.... The MCAI describes the unsafe condition as burnt electrical connectors leading to the left-hand... Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590. Hand Delivery: U.S...

  7. Survey on the implementation and reliability of CubeSat electrical bus interfaces

    NASA Astrophysics Data System (ADS)

    Bouwmeester, Jasper; Langer, Martin; Gill, Eberhard

    2017-06-01

    This paper provides results and conclusions on a survey on the implementation and reliability aspects of CubeSat bus interfaces, with an emphasis on the data bus and power distribution. It provides recommendations for a future CubeSat bus standard. The survey is based on a literature study and a questionnaire representing 60 launched CubeSats and 44 to be launched CubeSats. It is found that the bus interfaces are not the main driver for mission failures. However, it is concluded that the Inter Integrated Circuit (I2C) data bus, as implemented in a great majority of the CubeSats, caused some catastrophic satellite failures and a vast amount of bus lockups. The power distribution may lead to catastrophic failures if the power lines are not protected against overcurrent. A connector and wiring standard widely implemented in CubeSats is based on the PC/104 standard. Most participants find the 104 pin connector of this standard too large. For a future CubeSat bus interface standard, it is recommended to implement a reliable data bus, a power distribution with overcurrent protection and a wiring harness with smaller connectors compared with PC/104.

  8. Development of the Orion Crew-Service Module Umbilical Retention and Release Mechanism

    NASA Technical Reports Server (NTRS)

    Delap, Damon C.; Glidden, Joel Micah; Lamoreaux, Christopher

    2013-01-01

    The Orion CSM umbilical retention and release mechanism supports and protects all of the cross-module commodities between the spacecrafts crew and service modules. These commodities include explosive transfer lines, wiring for power and data, and flexible hoses for ground purge and life support systems. The mechanism employs a single separation interface which is retained with pyrotechnically actuated separation bolts and supports roughly two dozen electrical and fluid connectors. When module separation is commanded, either for nominal on-orbit CONOPS or in the event of an abort, the mechanism must release the separation interface and sever all commodity connections within milliseconds of command receipt. There are a number of unique and novel aspects of the design solution developed by the Orion mechanisms team. The design is highly modular and can easily be adapted to other vehiclesmodules and alternate commodity sets. It will be flight tested during Orions Exploration Flight Test 1 (EFT-1) in 2014, and the Orion team anticipates reuse of the design for all future missions. The design packages fluid, electrical, and ordnance disconnects in a single separation interface. It supports abort separations even in cases where aerodynamic loading prevents the deployment of the umbilical arm. Unlike the Apollo CSM umbilical which was a destructive separation device, the Orion design is resettable and flight units can be tested for separation performance prior to flight.Initial development testing of the mechanisms separation interface resulted in binding failures due to connector misalignments. The separation interface was redesigned with a robust linear guide system, and the connector separation and boom deployment were separated into two discretely sequenced events. These changes addressed the root cause of the binding failure by providing better control of connector alignment. The new design was tuned and validated analytically via Monte Carlo simulation. The analytical validation was followed by a repeat of the initial test suite plus test cases at thermal extremes and test cases with imposed mechanical failures demonstrating fault tolerance. The mechanism was then exposed to the qualification vibration environment. Finally, separation testing was performed at full speed with live ordnance.All tests of the redesigned mechanism resulted in successful separation of the umbilical interface with adequate force margins and timing. The test data showed good agreement with the predictions of the Monte Carlo simulation. The simulation proved invaluable due to the number of variables affecting the separation and the uncertainty associated with each. The simulation allowed for rapid assessment of numerous trades and contingency scenarios, and can be easily reconfigured for varying commodity sets and connector layouts.

  9. Optical digital techniques

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Optical interface losses between transmitter-to-fiber interface, connector-to-connector interface, and fiber-to-receiver interface were studied. System effects such as pulse dispersion, risetimes of the sources and detectors, type of fibers used, output power of the sources, and detector sensitivity were considered. Data bus systems such as TEE, Star, and Hybrid were analyzed. The matter of single fiber versus bundle technologies for future avionics systems was considered. The existing data bus system on Space Shuttle was examined and an optical analog was derived for a fiber bundle system, along with the associated power margin. System tests were performed on a feasibility model of a 9-port Star data bus system including BER, star losses, connector losses, etc. The same system was subjected to EMI between the range of 200 Hz to 10 GHz at 20V/m levels. A lightning test was also performed which simulated the conditions similar to those on Space Shuttle. The data bus system was found to be EMI and lightning hard. It is concluded that an optical data bus system is feasible for shuttle orbiter type vehicles.

  10. Double interconnection fuel cell array

    DOEpatents

    Draper, R.; Zymboly, G.E.

    1993-12-28

    A fuel cell array is made, containing number of tubular, elongated fuel cells which are placed next to each other in rows (A, B, C, D), where each cell contains inner electrodes and outer electrodes, with solid electrolyte between the electrodes, where the electrolyte and outer electrode are discontinuous, having two portions, and providing at least two opposed discontinuities which contain at least two oppositely opposed interconnections contacting the inner electrode, each cell having only three metallic felt electrical connectors which contact surrounding cells, where each row is electrically connected to the other. 5 figures.

  11. Misalignment Accommodating Connector Assembly

    NASA Technical Reports Server (NTRS)

    Stemper, Jack S. (Inventor)

    1998-01-01

    Misalignment accommodating connector assembly for removably connecting first and second objects which may comprise: a first connector subassembly having an arm member extending therefrom transversely through which is provided a tubular member; a second connector subassembly having a pair of spaced apart arm members each of which is provided with a transversely disposed coaxially aligned semi-cylindrical recess for receiving opposite ends of the first connector tubular member upon lateral insertion of the first connector arm member into the space between the second connector pair of arm members. An axially extendable and contractible fastener subassembly carried by the first connector tubular member is extendable to allow insertion or removal of the first connector arm member into or from the space between the second connector pair of arm members and contractible when the opposite ends of the tubular member are substantially received by the semi-cylindrical recesses of the pair of spaced apart arm members to lock the first and second connector subassemblies together.

  12. Oxygenator Safety Evaluation: A Focus on Connection Grip Strength and Arterial Temperature Measurement Accuracy

    PubMed Central

    Newland, Richard F.; Baker, Robert A.; Sanderson, Andrew J.; Tuble, Sigrid C.; Tully, Phil J.

    2012-01-01

    Abstract: This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT® tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT® connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT® tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity®, Sorin Synthesis®, Sorin Primox®, and Terumo Capiox® RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio®, Trillium®, Carmeda®, X-Coating®, and SMARxT® tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT® tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, ηp2 = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15°C, whilst at temperatures ≥25°C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT® tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential. PMID:22893983

  13. Package architecture and component design for an implanted neural stimulator with closed loop control.

    PubMed

    Bjune, Caroline K; Marinis, Thomas F; Brady, Jeanne M; Moran, James; Wheeler, Jesse; Sriram, Tirunelveli S; Parks, Philip D; Widge, Alik S; Dougherty, Darin D; Eskandar, Emad N

    2015-08-01

    An implanted neural stimulator with closed loop control requires electrodes for stimulation pulses and recording neuron activity. Our system features arrays of 64 electrodes. Each electrode can be addressed through a cross bar switch, to enable it to be used for stimulation or recording. This electrode switch, a bank of low noise amplifiers with an integrated analog to digital converter, power conditioning electronics, and a communications and control gate array are co-located with the electrode array in a 14 millimeter diameter satellite package that is designed to be flush mounted in a skull burr hole. Our system features five satellite packages connected to a central hub processor-controller via ten conductor cables that terminate in a custom designed, miniaturized connector. The connector incorporates features of high reliability, military grade devices and utilizes three distinct seals to isolate the contacts from fluid permeation. The hub system is comprised of a connector header, hermetic electronics package, and rechargeable battery pack, which are mounted on and electrically interconnected by a flexible circuit board. The assembly is over molded with a compliant silicone rubber. The electronics package contains two antennas, a large coil, used for recharging the battery and a high bandwidth antenna that is used to download data and update software. The package is assembled from two machined alumina pieces, a flat base with brazed in, electrical feed through pins and a rectangular cover with rounded corners. Titanium seal rings are brazed onto these two pieces so that they can be sealed by laser welding. A third system antenna is incorporated in the flexible circuit board. It is used to communicate with an externally worn control package, which monitors the health of the system and allows both the user and clinician to control or modify various system function parameters.

  14. High-Speed Isolation Board for Flight Hardware Testing

    NASA Technical Reports Server (NTRS)

    Yamamoto, Clifford K.; Goodpasture, Richard L.

    2011-01-01

    There is a need to provide a portable and cost-effective galvanic isolation between ground support equipment and flight hardware such that any unforeseen voltage differential between ground and power supplies is eliminated. An interface board was designed for use between the ground support equipment and the flight hardware that electrically isolates all input and output signals and faithfully reproduces them on each side of the interface. It utilizes highly integrated multi-channel isolating devices to minimize size and reduce assembly time. This single-board solution provides appropriate connector hardware and breakout of required flight signals to individual connectors as needed for various ground support equipment. The board utilizes multi-channel integrated circuits that contain transformer coupling, thereby allowing input and output signals to be isolated from one another while still providing high-fidelity reproduction of the signal up to 90 MHz. The board also takes in a single-voltage power supply input from the ground support equipment and in turn provides a transformer-derived isolated voltage supply to power the portion of the circuitry that is electrically connected to the flight hardware. Prior designs used expensive opto-isolated couplers that were required for each signal to isolate and were time-consuming to assemble. In addition, these earlier designs were bulky and required a 2U rack-mount enclosure. The new design is smaller than a piece of 8.5 11-in. (.22 28-mm) paper and can be easily hand-carried where needed. The flight hardware in question is based on a lineage of existing software-defined radios (SDRs) that utilize a common interface connector with many similar input-output signals present. There are currently four to five variations of this SDR, and more upcoming versions are planned based on the more recent design.

  15. Stable polyurethane coatings for electronic circuits. NASA tech briefs, fall 1982, volume 7, no. 1

    NASA Technical Reports Server (NTRS)

    1982-01-01

    One of the most severe deficiencies of polyurethanes as engineering materials for electrical applications has been their sensitivity to combined humidity and temperature environments. Gross failure by reversion of urethane connector potting materials has occurred under these conditions. This has resulted in both scrapping of expensive hardware and reduction in reliability in other instances. A basic objective of this study has been to gain a more complete understanding of the mechanisms and interactions of moisture in urethane systems to guide the development of reversion resistant materials for connector potting and conformal coating applications in high humidity environments. Basic polymer studies of molecular weight and distribution, polymer structure, and functionality were carried out to define those areas responsible for hydrolytic instability and to define polymer structural feature conducive to optimum hydrolytic stability.

  16. Evolution of optical fibre cabling components at CERN: Performance and technology trends analysis

    NASA Astrophysics Data System (ADS)

    Shoaie, Mohammad Amin; Meroli, Stefano; Machado, Simao; Ricci, Daniel

    2018-05-01

    CERN optical fibre infrastructure has been growing constantly over the past decade due to ever increasing connectivity demands. The provisioning plan and fibre installation of this vast laboratory is performed by Fibre Optics and Cabling Section at Engineering Department. In this paper we analyze the procurement data for essential fibre cabling components during a five-year interval to extract the existing trends and anticipate future directions. The analysis predicts high contribution of LC connector and an increasing usage of multi-fibre connectors. It is foreseen that single-mode fibres become the main fibre type for mid and long-range installations while air blowing would be the major installation technique. Performance assessment of various connectors shows that the expanded beam ferrule is favored for emerging on-board optical interconnections thanks to its scalable density and stable return-loss.

  17. Tunnel junction multiple wavelength light-emitting diodes

    DOEpatents

    Olson, J.M.; Kurtz, S.R.

    1992-11-24

    A multiple wavelength LED having a monolithic cascade cell structure comprising at least two p-n junctions, wherein each of said at least two p-n junctions have substantially different band gaps, and electrical connector means by which said at least two p-n junctions may be collectively energized; and wherein said diode comprises a tunnel junction or interconnect. 5 figs.

  18. 78 FR 19090 - Airworthiness Directives; Embraer S.A. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-29

    ...We are adopting a new airworthiness directive (AD) for certain Embraer S.A. Model ERJ 170 and ERJ 190 airplanes. This AD was prompted by a report that high rate discharge (HRD) bottle explosive cartridges of a cargo compartment fire extinguisher system were swapped between the forward and aft cargo compartments. Additional investigation also revealed the possibility of swapping between the electrical connectors of the HRD and low rate discharge (LRD) bottles, and a rotated installation of the HRD bottle. Improper assembly of the fire extinguishing bottle might cause the extinguishing agent to be discharged toward the unselected cargo compartment rather than toward the cargo compartment with fire. This AD requires an inspection of the HRD bottle for correct installation and to determine if the pressure switch is in the correct position, and re-installation if necessary; an inspection of the HRD and LRD bottle discharge heads to determine the part number, and replacement if necessary; and, for certain airplanes, an inspection to identify the HRD and LRD bottle electrical connectors, and relocation if necessary. We are issuing this AD to prevent the inability of the fire extinguishing system to suppress fire.

  19. Lightweight electrical connector split backshell

    NASA Technical Reports Server (NTRS)

    Goldman, Elliot (Inventor)

    2009-01-01

    An electrical connector split backshell is provided, comprising two substantially identical backshell halves. Each half includes a first side and a cam projecting therefrom along an axis perpendicular thereto, the cam having an alignment tooth with a constant radius and an engagement section with a radius that increases with angular distance from the alignment tooth. Each half further includes a second side parallel to the first side and a circular sector opening disposed in the second side, the circular sector opening including an inner surface configured as a ramp with a constant radius, the ramp being configured to engage with an engagement section of a cam of the other half, the circular sector opening further including a relieved pocket configured to receive an alignment tooth of the cam of the other half. Each half further includes a back side perpendicular to the first and second sides and a wire bundle notch disposed in the back side, the wire bundle notch configured to align with a wire bundle notch of the other half to form a wire bundle opening. The two substantially identical halves are rotatably coupled by engaging the engagement section of each half to the ramp of the other half.

  20. Transpiration cooled electrodes and insulators for MHD generators

    DOEpatents

    Hoover, Jr., Delmer Q.

    1981-01-01

    Systems for cooling the inner duct walls in a magnetohydrodynamic (MHD) generator. The inner face components, adjacent the plasma, are formed of a porous material known as a transpiration material. Selected cooling gases are transpired through the duct walls, including electrically insulating and electrode segments, and into the plasma. A wide variety of structural materials and coolant gases at selected temperatures and pressures can be utilized and the gases can be drawn from the generation system compressor, the surrounding environment, and combustion and seed treatment products otherwise discharged, among many other sources. The conduits conducting the cooling gas are electrically insulated through low pressure bushings and connectors so as to electrically isolate the generator duct from the ground.

  1. An Analysis of the Load-Bearing Capacity of Timber-Concrete Composite Beams with Profiled Sheeting

    NASA Astrophysics Data System (ADS)

    Szumigała, Maciej; Szumigała, Ewa; Polus, Łukasz

    2017-12-01

    This paper presents an analysis of timber-concrete composite beams. Said composite beams consist of rectangular timber beams and concrete slabs poured into the steel sheeting. The concrete slab is connected with the timber beam using special shear connectors. The authors of this article are trying to patent these connectors. The article contains results from a numerical analysis. It is demonstrated that the type of steel sheeting used as a lost formwork has an influence on the load-bearing capacity and stiffness of the timber-concrete composite beams.

  2. Backplane photonic interconnect modules with optical jumpers

    NASA Astrophysics Data System (ADS)

    Glebov, Alexei L.; Lee, Michael G.; Yokouchi, Kishio

    2005-03-01

    Prototypes of optical interconnect (OI) modules for backplane applications are presented. The transceivers attached to the linecards E/O convert the signals that are passed to and from the backplane by optical jumpers terminated with MTP-type connectors. The connectors plug into adaptors attached to the backplane and the microlens arrays mounted in the adaptors couple the light between the fibers and waveguides. Planar polymer channel waveguides with 30-50 μm cross-sections route the optical signals across the board with propagation losses as low as 0.05 dB/cm @ 850 nm. The 45¦-tapered integrated micromirrors reflect the light in and out of the waveguide plane with the loss of 0.8 dB per mirror. The connector displacement measurements indicate that the adaptor lateral assembly accuracy can be at least +/-10 μm for the excess loss not exceeding 1 dB. Insertion losses of the test modules with integrated waveguides, 45¦ mirrors, and pluggable optical jumper connectors are about 5 dB. Eye diagrams at 10.7 Gb/s have typical width and height of 70 ps and 400 mV, respectively, and jitter of about 20 ps.

  3. Homogeneous and single-side-operational connector mechanism for self-reconfigurable, self-assembly and self-healing systems

    NASA Technical Reports Server (NTRS)

    Shen, Wei-Min (Inventor); Kovac, Robert M. (Inventor)

    2012-01-01

    Designs of single-end-operative reconfigurable genderless connectors that include a base, a plurality of movable jaws that are formed on the base and can engage to the jaws of another connector, and an actuator that is mounted on the base and can engage and move the jaws of the reconfigurable connector to connect the reconfigurable connector with another connector.

  4. The biomechanical effect of transverse connectors use in a pre- and postlaminectomy model of the posterior cervical spine: an in vitro cadaveric study.

    PubMed

    Majid, Kamran; Gudipally, Manasa; Hussain, Mir; Moldavsky, Mark; Khalil, Saif

    2011-12-15

    An in vitro biomechanical study investigating the effect of transverse connectors on posterior cervical stabilization system in a laminectomy model. To evaluate the optimal design, number, and location of the transverse connectors in stabilizing long segment posterior instrumentation in the cervical spine. In the cervical spine, lateral mass screw (LMS) fixation is used for providing stability after decompression. Transverse connectors have been used to augment segmental posterior instrumentation. However, in the cervical region the optimal design, number, and the location of transverse connectors is not known. Seven fresh human cervicothoracic cadaveric spines (C2-T1) were tested by applying ±1.5 Nm moments in flexion (F), extension (E), lateral bending (LB), and axial rotation (AR). After testing the intact condition, LMS/rods were placed and then were tested with two different transverse connectors (top-loading connector [TL] and the head-to-head [HH] connector) in multiple levels, pre- and postlaminectomy (PL). LMS significantly reduced segmental motion by 77.2% in F, 75.6% in E, 86.6% in LB, and 86.1% in AR prelaminectomy and by 75.4% in F, 76% in E, 80.6% in LB, and 76.4% in AR postlaminectomy compared to intact (P < 0.05). Only in AR, PL constructs with HH connectors at C3 & C7, TL connectors at C4-C5 & C5-C6, and at C3-C4 & C6-C7 significantly reduced the range of motion by 12.9%, 11.9%, and 11.9%, respectively, compared to PL LMS (P < 0.05). No statistical significance was observed between TL connector and HH connector in all loading directions. The biomechanical advantage of transverse connectors is significant in AR, when using two connectors at the proximal and distal ends, compared to one connector. In a clinical setting, this data may guide surgeons on transverse connector configurations to consider during posterior cervical instrumentation.

  5. Remote Coupling of Electrical Connectors

    NASA Technical Reports Server (NTRS)

    Barbour, R. T.

    1985-01-01

    Device alines plug and receptacle axially and radially. Standard multiple-pin plug and socket mounted in mechanism. As threaded shaft moves out from its mounting bracket, two sets of petals engage each other and correct misalinement. Misalinement absorbed by spring-mounted swivels. Designed for umbilical cables between Space Shuttle and payload, mechanism adaptable to other remote or hazardous situations in which human not available to connect mating parts by hand.

  6. EMPFASIS: A Publication of the National Electronics Manufacturing Center of Excellence

    DTIC Science & Technology

    2010-01-01

    for moisture, salt spray, and wind driven rain protection. • Conversion to ruggedized electrical and fluid connectors. • Additional circuitry, if...computer control technology, designed for safe lead free and eutectic rework applications. Available in two models, the RD-500 series features a three-stage...shock, Temperature Humidity Bias (THB) Testing, Highly Accelerated Stress Testing (HAST), salt fog, high temperature storage, or other environmental

  7. Corrosion Monitors for Embedded Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, Alex L.; Pfeifer, Kent B.; Casias, Adrian L.

    2017-05-01

    We have developed and characterized novel in-situ corrosion sensors to monitor and quantify the corrosive potential and history of localized environments. Embedded corrosion sensors can provide information to aid health assessments of internal electrical components including connectors, microelectronics, wires, and other susceptible parts. When combined with other data (e.g. temperature and humidity), theory, and computational simulation, the reliability of monitored systems can be predicted with higher fidelity.

  8. Materials investigation and tests for the development of space compatible electrical connectors

    NASA Technical Reports Server (NTRS)

    Pomeroy, C.; Mccabe, T.

    1971-01-01

    A molding study of compounds based on copolymers of highly fluorinated olefins and of flame retardant silicone is reported. Both single cavity and four cavity molds having size 22 and 24 holes with three webs in each hole were used. Also covered are dielectric strength, arc resistance, Bashore rebound, and maintenance aging tests on the various materials that have been successfully molded.

  9. Shock Absorbers Save Structures and Lives during Earthquakes

    NASA Technical Reports Server (NTRS)

    2015-01-01

    With NASA funding, North Tonawanda, New York-based Taylor Devices Inc. developed fluidic shock absorbers to safely remove the fuel and electrical connectors from the space shuttles during launch. The company is now employing the technology as seismic dampers to protect structures from earthquakes. To date, 550 buildings and bridges have the dampers, and not a single one has suffered damage in the wake of an earthquake.

  10. Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs.

    PubMed

    Esquivel-Upshaw, Josephine F; Anusavice, Kenneth J; Young, Henry; Jones, Jack; Gibbs, Charles

    2004-01-01

    The purpose of this research project was to determine the clinical success rate of a lithia disilicate-based core ceramic for use in posterior fixed partial dentures (FPD) as a function of bite force, cement type, connector height, and connector width. Thirty ceramic FPD core frameworks were prepared using a heat-pressing technique and a lithia disilicate-based core ceramic. The maximum clenching force was measured for each patient prior to tooth preparation. Connector height and width were measured for each FPD. Patients were recalled yearly after cementation for 2 years and evaluated using 11 clinical criteria. All FPDs were examined by two independent clinicians, and rankings from 1 to 4 were made for each criterion (4 = excellent; 1 = unacceptable). Two of the 30 ceramic FPDs fractured within the 2-year evaluation period, representing a 93% success rate. One fracture was associated with a low occlusal force and short connector height (2.9 mm). The other fracture was associated with the greatest occlusal force (1,031 N) and adequate connector height. All criteria were ranked good to excellent during the 2-year recall for all remaining FPDs. The performance of the experimental core ceramic in posterior FPDs was promising, with only a 7% fracture rate after 2 years. Because of the limited sample size, it is not possible to identify the maximum clenching force that is allowable to prevent fracture caused by interocclusal forces.

  11. Advanced motor driven clamped borehole seismic receiver

    DOEpatents

    Engler, Bruce P.; Sleefe, Gerard E.; Striker, Richard P.

    1993-01-01

    A borehole seismic tool including a borehole clamp which only moves perpendicular to the borehole. The clamp is driven by an electric motor, via a right angle drive. When used as a seismic receiver, the tool has a three part housing, two of which are hermetically sealed. Accelerometers or geophones are mounted in one hermetically sealed part, the electric meter in the other hermetically sealed part, and the clamp and right angle drive in the third part. Preferably the tool includes cable connectors at both ends. Optionally a shear plate can be added to the clamp to extend the range of the tool.

  12. Four-terminal electrical testing device. [initiator bridgewire resistance

    NASA Technical Reports Server (NTRS)

    Robinson, Robert L. (Inventor); Graves, Thomas J. (Inventor); Hoffman, William C., III (Inventor)

    1987-01-01

    The invention relates to a four-terminal electrical connector device for testing and measuring unknown resistances of initiators used for starting pyrotechnic events aboard the space shuttle. The testing device minimizes contact resistance degradation effects and so improves the reliability of resistance measurements taken with the device. Separate and independent voltage sensing and current supply circuits each include a pair of socket contacts for mating engagement with the pins of the initiator. The unknown resistance that is measured by the device is the resistance of the bridgewire of the initiator which is required to be between 0.95 and 1.15 ohms.

  13. Aircraft-mounted crash-activated transmitter device

    NASA Technical Reports Server (NTRS)

    Manoli, R.; Ulrich, B. R. (Inventor)

    1976-01-01

    An aircraft crash location transmitter tuned to transmit on standard emergency frequencies is reported that is shock mounted in a sealed circular case atop the tail of an aircraft by means of a shear pin designed to fail under a G loading associated with a crash situation. The antenna for the transmitter is a metallic spring blade coiled like a spiral spring around the outside of the circular case. A battery within the case for powering the transmitter is kept trickle charged from the electrical system of the aircraft through a break away connector on the case. When a crash occurs, the resultant ejection of the case from the tail due to a failure of the shear pin releases the free end of the antenna which automatically uncoils. The accompanying separation of the connector effects closing of the transmitter key and results in commencement of transmission.

  14. Dust and Debris Tolerant Dual Poppet Valve Connector

    NASA Technical Reports Server (NTRS)

    Townsend, III, Ivan I. (Inventor); Mueller, Robert P. (Inventor); Bastin, Gary L. (Inventor); Carlson, Jeffrey W. (Inventor); Murtland, Kevin A. (Inventor)

    2017-01-01

    A debris exclusion and removal apparatus for connectors which have a dual-poppet value configuration containing a pressurized substance. Coupling of the female and male connectors causes the poppet valve to eject a cleaning substance which will eliminate debris from the male connector prior to mating with the female connector.

  15. Cable Tester Box

    NASA Technical Reports Server (NTRS)

    Lee, Jason H.

    2011-01-01

    Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

  16. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.

    PubMed

    Ivanov, Vadim A

    2016-02-01

    The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination in a model of the premature neonate lung. The standard ETT connector was compared with a low-dead-space ETT connector and with a standard connector equipped with an insert. We compared the setups by measuring the CO2 elimination rate in an artificial lung ventilated via the connectors. The lung was connected to a ventilator via a standard circuit, a 2.5-mm ETT, and one of the connectors under investigation. The ventilator was run in volume-controlled continuous mandatory ventilation mode. The low-dead-space ETT connector/Y-piece and insert-equipped standard connector/Y-piece pairs had instrumental dead space reduced by 36 and 67%, respectively. With set tidal volumes (VT) of 2.5, 5, and 10 mL, in comparison with the standard ETT connector, the low-dead-space connector reduced CO2 elimination time by 4.5% (P < .05), 4.4% (P < .01), and 7.1% (not significant), respectively. The insert-equipped standard connector reduced CO2 elimination time by 13.5, 25.1, and 16.1% (all P < .01). The low-dead-space connector increased inspiratory resistance by 17.8% (P < .01), 9.6% (P < .05), and 5.0% (not significant); the insert-equipped standard connector increased inspiratory resistance by 9.1, 8.4, and 5.9% (all not significant). The low-dead-space connector decreased expiratory resistance by 6.8% (P < .01) and 1.8% (not significant) and increased it by 1.4% (not significant); the insert-equipped standard connector decreased expiratory resistance by 1.5 and 1% and increased it by 1% (all not significant). The low-dead-space connector increased work of breathing by 4.7% (P < .01), 3.8% (P < .01), and 2.5% (not significant); the insert-equipped standard connector increased it by 0.8% (not significant), 2.5% (P < .01), and 2.8% (P < .01). Both methods of instrumental dead-space reduction led to improvements in artificial lung ventilation. Negative effects on resistance and work of breathing appeared minimal. Further testing in vivo should be performed to confirm the lung model results and, if successful, translated into clinical practice. Copyright © 2016 by Daedalus Enterprises.

  17. Reliable optical card-edge (ROC) connector for avionics applications

    NASA Astrophysics Data System (ADS)

    Darden, Bruce V.; Pimpinella, Richard J.; Seals, John D.

    1994-10-01

    The Reliable Optical Card-Edge (ROC) Connector is a blind-mate backplane unit designed to meet military stress requirements for avionics applications. Its modular design represents the first significant advance in connector optics since the biconic butt-coupled connector was introduced twenty years ago. This multimode connector utilizes beam optics, micro-machined silicon, and a floating, low mass subassembly design to maintain low coupling loss under high levels of shock and vibration. The ROC connector also incorporates retracting doors to protect the unmated termini from environmental contamination and abusive handling. Design features and test results for the ROC connector are presented in this paper.

  18. Catheter Occlusion in Home Infusion: The Influence of Needleless Connector Design on Central Catheter Occlusion.

    PubMed

    Williams, Ann

    Thrombotic catheter occlusion is a common complication associated with central venous catheters (CVCs). A wide variety of needleless connectors that differ greatly in design and function are available for use with CVCs; however, there are a limited number of studies comparing the catheter occlusion rate associated with differently designed needleless connectors. This retrospective observational study compared occlusion rates associated with a split-septum neutral-displacement needleless connector versus those of a solid-surface neutral-reflux needleless connector in patients undergoing home infusion therapy. The neutral-reflux needleless connector was associated with a significant reduction in occlusion rate and thrombolytic use versus the neutral-displacement needleless connector.

  19. Proceedings of the Workshop on Mobility and Control in Challenging Environments

    DTIC Science & Technology

    2007-09-20

    1.18 h (V) -3.48 Electronic Nervous Systems Activating Nitinol With Electronic Neurons Controlling Walking With EN Networks ele dep prot ret forward...command backward command Myomorphic Actuators •Artificial Muscle Nitinol : 50/50 Alloy of Nickel and Titanium. • Two stable crystalline states • State...an electrical current through it causing conversion to austenite and shorteningText Kevlar “Tendon” Crimp Connector Teflon Coated Nitinol Current

  20. Cabling design for phased arrays

    NASA Technical Reports Server (NTRS)

    Kruger, I. D.; Turkiewicz, L.

    1972-01-01

    The ribbon-cabling system used for the AEGIS phased array which provides minimum cable bulk, complete EMI shielding, rugged mechanical design, repeatable electrical characteristics, and ease of assembly and maintenance is described. The ribbon cables are 0.040-inch thick, and in widths up to 2 1/2 inches. Their terminations are molded connectors that can be grouped in a three-tier arrangement, with cable branching accomplished by a matrix-welding technique.

  1. Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.

    PubMed

    Cordaro, Luca; Ercoli, Carlo; Rossini, Carlo; Torsello, Ferruccio; Feng, Changyong

    2005-10-01

    The clinical outcome of complete-arch fixed prostheses supported by implants and natural tooth abutments in patients with normal or reduced periodontal support has been reported by few studies, with controversial results. The purpose of this study was to report on the implant success rate, prosthetic complications, and the occurrence of tooth intrusion, when complete-arch fixed prostheses, supported by a combination of implants and teeth, were fabricated for patients with normal and reduced periodontal support. Nineteen patients with residual teeth that served as abutments were consecutively treated with combined tooth- and implant-supported complete-arch fixed prostheses and were retrospectively evaluated after a period varying from 24 to 94 months. Nine patients showed reduced periodontal support as a result of periodontal disease and treatment (RPS group), and 10 patients had normal periodontal support of the abutment teeth (more than 2/3 of periodontal support [NPS group]). Ninety implants and 72 tooth abutments were used to support 19 fixed partial dentures. Screw- and cement-retained metal-ceramic and metal-resin prostheses were fabricated with rigid and nonrigid connectors. Implant survival and success rates, occurrence of caries and tooth intrusion, and prosthetic complications were recorded. The number of teeth, implants, prosthetic units, fixed partial dentures, and nonrigid connectors were compared with a t test to assess differences between the 2 groups, while data for the occurrence of intrusions and prosthetic complications were compared with the Fisher exact test (alpha=.05). One of the 90 implants was lost (99% survival rate) over 24 to 94 months, while 3 implants showed more than 2 mm of crestal bone loss (96% success rate) over the same period. No caries were detected, but 5.6% (4/72) of the abutment teeth exhibited intrusion. Intrusion of abutment teeth was noted in 3 patients who had normal periodontal support (13% of teeth in NPS group) of the abutment teeth and was associated with nonrigid connectors. No intrusion of teeth was noted in the patients exhibiting reduced periodontal support regardless of the type of connector or when a rigid connector was used for either group. The number of intruded teeth was significantly greater in patients with intact periodontal support (P=.03). Complete-arch fixed prosthesis supported by implant and tooth abutments may be associated with intrusion of teeth with intact periodontal support when nonrigid connectors are used to join the implant- and tooth-supported sections of the prostheses. However, fixed partial dentures supported by implants and teeth with reduced periodontal support were not associated with tooth intrusion, regardless of the type of connectors used.

  2. Initial Performance Evaluation of Optical Fibers and Sensors Under High-Energy Electron Beam Irradiation

    NASA Astrophysics Data System (ADS)

    Palmer, Matthew E.; Slusher, David; Fielder, Robert S.

    2006-01-01

    In this paper, recent work on the performance of optical fiber, fiber optic sensors, and fiber optic connectors under the influence of a high-energy electron beam is presented. Electron beam irradiation is relevant for the Jupiter Icy Moons Orbiter (JIMO) mission due to the high electron radiation environment surrounding Jupiter. As an initial feasibility test, selected optical fiber components were exposed to dose levels relevant to the Jupiter environment. Three separate fiber types were used: one series consisted of pure silica core fiber, two other series consisted of different levels of Germania-doped fiber. Additionally, a series of fused silica Extrinsic Fabry-Perot Interferometer (EFPI)-based fiber optic sensors and two different types of fiber optic connectors were tested. Two types of fiber coatings were evaluated: acrylate and polyimide. All samples were exposed to three different dose levels: 2 MRad, 20 MRad, and 50 MRad. Optical loss measurements were made on the optical fiber spools as a function of wavelength between 750 and 1750nm at periodic intervals up to 75 hrs after exposure. Attenuation is minimal and wavelength-dependent. Fiber optic sensors were evaluated using a standard EFPI sensor readout and diagnostic system. Optical connectors and optical fiber coatings were visually inspected for degradation. Additionally, tensile testing and minimum bend radius testing was conducted on the fibers. Initial loss measurements indicate a low-level of induced optical attenuation in the fiber which recovers with time. The fiber optic sensors exhibited no observable degradation after exposure. The optical fiber connectors and coatings also showed no observable degradation. In addition to harsh environment survivability, fiber optic sensors offer a number of intrinsic advantages for space nuclear power applications including extremely low mass, immunity to electromagnetic interference, self diagnostics / prognostics, and smart sensor capability. Deploying fiber optic sensors on future space exploration missions would provide a substantial improvement in spacecraft instrumentation.

  3. Charge-Dissipative Electrical Cables

    NASA Technical Reports Server (NTRS)

    Kolasinski, John R.; Wollack, Edward J.

    2004-01-01

    Electrical cables that dissipate spurious static electric charges, in addition to performing their main functions of conducting signals, have been developed. These cables are intended for use in trapped-ion or ionizing-radiation environments, in which electric charges tend to accumulate within, and on the surfaces of, dielectric layers of cables. If the charging rate exceeds the dissipation rate, charges can accumulate in excessive amounts, giving rise to high-current discharges that can damage electronic circuitry and/or systems connected to it. The basic idea of design and operation of charge-dissipative electrical cables is to drain spurious charges to ground by use of lossy (slightly electrically conductive) dielectric layers, possibly in conjunction with drain wires and/or drain shields (see figure). In typical cases, the drain wires and/or drain shields could be electrically grounded via the connector assemblies at the ends of the cables, in any of the conventional techniques for grounding signal conductors and signal shields. In some cases, signal shields could double as drain shields.

  4. SLIIC: System-Level Intelligent Intensive Computing

    DTIC Science & Technology

    2004-12-01

    E M em or y S D R A M :2 56 M B to t Imagine B Host Interface N W S... E M em or y S D R A M :2 56 M B to t Firewire B Connector Firewire A Connector DVI In Connector DVI Out ConnectorHSTL Connector HSTL Connector D eb...6N 7N0 N 2N 3N 1 N+1 2N+ 1 3N+1 (b) Upper strip (c) Output stream from upper strip (d) Lower strip ( e ) Output stream from lower strip (f)

  5. Color-Coded Labels Cued Nurses to Adhere to Central Line Connector Change.

    PubMed

    Morrison, Theresa Lynch; Laney, Christina; Foglesong, Jan; Brennaman, Laura

    2016-01-01

    This study examined nurses' adherence to policies regarding needleless connector changes using a novel, day-of-the-week, color-coded label compared with usual care that relied on electronic medical record (EMR) documentation. This was a prospective, comparative study. The study was performed on 4 medical-surgical units in a seasonally fluctuating, 715-bed healthcare system composed of 2 community hospitals. Convenience sample was composed of adults with central lines hospitalized for 4 or more days. At 4-day intervals, investigators observed bedside label use and EMR needleless connector change documentation. Control patients received standard care-needleless connector change with associated documentation in the EMR. Intervention patients, in addition to standard care, had a day-of-the-week, color-coded label placed on each needleless connector. To account for clustering within unit, multinomial logistic regression models using survey sampling methodology were used to conduct Wald χ tests. A multinominal odds ratio and 95% confidence interval (CI) provided an estimate of using labels that were provided on units relative to usual care documentation of needleless connector change in the EMR. In 335 central line observations, the units with labels (n = 205) had a 321% increase rate of documentation of needleless connector change in the EMR (odds ratio, 4.21; 95% CI, 1.76-10.10; P = .003) compared with the usual care control patients. For units with labels, when labels were present, placement of labels on needleless connectors increased the odds that nurses documented connector changes per policy (4.72; 95% CI, 2.02, 10.98; P = .003). Day-of-the-week, color-coded labels cued nurses to document central line needleless connector change in the EMR, which increased adherence to the needleless connector change policy. Providing day-of-the-week, color-coded needleless connector labels increased EMR documentation of timely needleless connector changes. Timely needleless connector changes may lower the incidence of central line-associated bloodstream infection.

  6. Cassini's RTGs undergo mechanical and electrical verification tests in the PHSF

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Jet Propulsion Laboratory (JPL) worker Mary Reaves mates connectors on a radioisotope thermoelectric generator (RTG) to power up the Cassini spacecraft, while quality assurance engineer Peter Sorci looks on. The three RTGs which will be used on Cassini are undergoing mechanical and electrical verification testing in the Payload Hazardous Servicing Facility. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed by JPL.

  7. The fabrication of a tapered fiber connector and its coupling efficiency

    NASA Astrophysics Data System (ADS)

    Qinggui, Hu; Chengzhong, Li

    2017-11-01

    In order to reduce the adverse influence of transversal displacement of the optical fiber connector, we propose the directional tapered communication fiber connector, in which the fiber head is tapered according to the signal transmission direction to improve efficiency. We used a flame-brush technique to produce the tapered fiber successfully. In the next step, two experiments in different environments were performed; one in a static environment and the other in a vibration environment. The first experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same transversal displacement. The second experiment shows that the efficiency of the tapered connector is higher than that of the common connector in the same frequency and amplitude.

  8. DNA conformational change induced by the bacteriophage phi 29 connector.

    PubMed Central

    Valpuesta, J M; Serrano, M; Donate, L E; Herranz, L; Carrascosa, J L

    1992-01-01

    Translocation of viral DNA inwards and outwards of the capsid of double-stranded DNA bacteriophages occurs through the connector, a key viral structure that is known to interact with DNA. It is shown here that phage phi 29 connector binds both linear and circular double-stranded DNA. However, DNA-mediated protection of phi 29 connectors against Staphylococcus aureus endoprotease V8 digestion suggests that binding to linear DNA is more stable than to circular DNA. Endoprotease V8-protection assays also suggest that the length of the linear DNA required to produce a stable phi 29 connector-DNA interaction is, at least, twice longer than the phi 29 connector channel. This result is confirmed by experiments of phi 29 connector-protection of DNA against DNase I digestion. Furthermore, DNA circularization assays indicate that phi 29 connectors restrain negative supercoiling when bound to linear DNA. This DNA conformational change is not observed upon binding to circular DNA and it could reflect the existence of some left-handed DNA coiling or DNA untwisting inside of the phi 29 connector channel. Images PMID:1454519

  9. Semantic integration of gene expression analysis tools and data sources using software connectors

    PubMed Central

    2013-01-01

    Background The study and analysis of gene expression measurements is the primary focus of functional genomics. Once expression data is available, biologists are faced with the task of extracting (new) knowledge associated to the underlying biological phenomenon. Most often, in order to perform this task, biologists execute a number of analysis activities on the available gene expression dataset rather than a single analysis activity. The integration of heteregeneous tools and data sources to create an integrated analysis environment represents a challenging and error-prone task. Semantic integration enables the assignment of unambiguous meanings to data shared among different applications in an integrated environment, allowing the exchange of data in a semantically consistent and meaningful way. This work aims at developing an ontology-based methodology for the semantic integration of gene expression analysis tools and data sources. The proposed methodology relies on software connectors to support not only the access to heterogeneous data sources but also the definition of transformation rules on exchanged data. Results We have studied the different challenges involved in the integration of computer systems and the role software connectors play in this task. We have also studied a number of gene expression technologies, analysis tools and related ontologies in order to devise basic integration scenarios and propose a reference ontology for the gene expression domain. Then, we have defined a number of activities and associated guidelines to prescribe how the development of connectors should be carried out. Finally, we have applied the proposed methodology in the construction of three different integration scenarios involving the use of different tools for the analysis of different types of gene expression data. Conclusions The proposed methodology facilitates the development of connectors capable of semantically integrating different gene expression analysis tools and data sources. The methodology can be used in the development of connectors supporting both simple and nontrivial processing requirements, thus assuring accurate data exchange and information interpretation from exchanged data. PMID:24341380

  10. Semantic integration of gene expression analysis tools and data sources using software connectors.

    PubMed

    Miyazaki, Flávia A; Guardia, Gabriela D A; Vêncio, Ricardo Z N; de Farias, Cléver R G

    2013-10-25

    The study and analysis of gene expression measurements is the primary focus of functional genomics. Once expression data is available, biologists are faced with the task of extracting (new) knowledge associated to the underlying biological phenomenon. Most often, in order to perform this task, biologists execute a number of analysis activities on the available gene expression dataset rather than a single analysis activity. The integration of heterogeneous tools and data sources to create an integrated analysis environment represents a challenging and error-prone task. Semantic integration enables the assignment of unambiguous meanings to data shared among different applications in an integrated environment, allowing the exchange of data in a semantically consistent and meaningful way. This work aims at developing an ontology-based methodology for the semantic integration of gene expression analysis tools and data sources. The proposed methodology relies on software connectors to support not only the access to heterogeneous data sources but also the definition of transformation rules on exchanged data. We have studied the different challenges involved in the integration of computer systems and the role software connectors play in this task. We have also studied a number of gene expression technologies, analysis tools and related ontologies in order to devise basic integration scenarios and propose a reference ontology for the gene expression domain. Then, we have defined a number of activities and associated guidelines to prescribe how the development of connectors should be carried out. Finally, we have applied the proposed methodology in the construction of three different integration scenarios involving the use of different tools for the analysis of different types of gene expression data. The proposed methodology facilitates the development of connectors capable of semantically integrating different gene expression analysis tools and data sources. The methodology can be used in the development of connectors supporting both simple and nontrivial processing requirements, thus assuring accurate data exchange and information interpretation from exchanged data.

  11. Advanced motor driven clamped borehole seismic receiver

    DOEpatents

    Engler, B.P.; Sleefe, G.E.; Striker, R.P.

    1993-02-23

    A borehole seismic tool is described including a borehole clamp which only moves perpendicular to the borehole. The clamp is driven by an electric motor, via a right angle drive. When used as a seismic receiver, the tool has a three part housing, two of which are hermetically sealed. Accelerometers or geophones are mounted in one hermetically sealed part, the electric motor in the other hermetically sealed part, and the clamp and right angle drive in the third part. Preferably the tool includes cable connectors at both ends. Optionally a shear plate can be added to the clamp to extend the range of the tool.

  12. Double interconnection fuel cell array

    DOEpatents

    Draper, Robert; Zymboly, Gregory E.

    1993-01-01

    A fuel cell array (10) is made, containing number of tubular, elongated fuel cells (12) which are placed next to each other in rows (A, B, C, D), where each cell contains inner electrodes (14) and outer electrodes (18 and 18'), with solid electrolyte (16 and 16') between the electrodes, where the electrolyte and outer electrode are discontinuous, having two portions, and providing at least two opposed discontinuities which contain at least two oppositely opposed interconnections (20 and 20') contacting the inner electrode (14), each cell (12) having only three metallic felt electrical connectors (22) which contact surrounding cells, where each row is electrically connected to the other.

  13. In Vitro Microbiology Studies on a New Peritoneal Dialysis Connector

    PubMed Central

    Di Bonaventura, Giovanni; Cerasoli, Paolo; Pompilio, Arianna; Arrizza, Fabio; Di Liberato, Lorenzo; Stingone, Antonio; Sirolli, Vittorio; Arduini, Arduino; Bonomini, Mario

    2012-01-01

    ♦ Objective: We evaluated the ability of a recently developed peritoneal dialysis (PD) connector to prevent the risk of bacterial transfer to the fluid path after simulated touch and airborne contamination. ♦ Methods: Staphylococcus epidermidis ATCC1228 and Pseudomonas aeruginosa ATCC27853 strains were used. For touch contamination, 2 μL of a standardized inoculum [1×108 colony-forming units (CFU) per milliliter] were deposited on top of the pin closing the fluid path of the patient connector. For airborne contamination, the patient connector was exposed for 15 seconds to a nebulized standardized inoculum. To simulate the patient peritoneum and effluent, the patient connector was pre-attached to a 2-L bag of sterile PD solution. After contamination, the patient connector was attached to the transfer set, the pin was captured, flow control was turned to simulate “patient drain” into the empty bag, and then “patient fill” using the bag pre-attached to the connector. Finally, a new pin was recaptured. The PD solution collected in the bag pre-attached to the connector was run through a 0.20-μm filter for colony counts. ♦ Results: No infected connector transferred bacteria to the fluid path, regardless of the challenge procedure or the strain used. ♦ Conclusions: Our results show that the new PD connector may fully obviate the risk of bacterial infection, even in the presence of heavy contamination. Further studies are in progress to test our PD connector in a clinical setting. PMID:22302771

  14. Electro-optical line cards with multimode polymer waveguides for chip-to-chip interconnects

    NASA Astrophysics Data System (ADS)

    Zhu, Long Xiu; Immonen, Marika; Wu, Jinhua; Yan, Hui Juan; Shi, Ruizhi; Chen, Peifeng; Rapala-Virtanen, Tarja

    2014-10-01

    In this paper, we report developments of electro-optical PCBs (EO-PCB) with low-loss (<0.05dB/cm) polymer waveguides. Our results shows successful fabrication of complex waveguide structures part of hybrid EO-PCBs utilizing production scale process on standard board panels. Test patterns include 90° bends of varying radii (40mm - 2mm), waveguide crossing with varied crossing angles (90°-20°), cascaded bends with varying radii, splitters and tapered waveguides. Full ranges of geometric configurations are required to meet practical optical routing functions and layouts. Moreover, we report results obtained to realize structures to integrate optical connectors with waveguides. Experimental results are shown for MT in-plane and 90° out-of-plane optical connectors realized with coupling loss < 2dB and < 2.5 dB, respectively. These connectors are crucial to realize efficient light coupling from/to TX/RX chip-to-waveguide and within waveguide-to-fiber connections in practical optical PCBs. Furthermore, we show results for fabricating electrical interconnect structures e.g. tracing layers, vias, plated vias top/bottom and through optical layers. Process compatibility with accepted practices and production scale up for high volumes are key concerns to meet the yield target and cost efficiency. Results include waveguide characterization, transmission loss, misalignment tolerance, and effect of lamination. Critical link metrics are reported.

  15. The connector space reduction mechanism

    NASA Technical Reports Server (NTRS)

    Milam, M. Bruce

    1990-01-01

    The Connector Space Reduction Mechanism (CSRM) is a simple device that can reduce the number of electromechanical devices on the Payload Interface Adapter/Station Interface Adapter (PIA/SIA) from 4 to 1. The device uses simplicity to attack the heart of the connector mating problem for large interfaces. The CSRM allows blind mate connector mating with minimal alignment required over short distances. This eliminates potential interface binding problems and connector damage. The CSRM is compatible with G and H connectors and Moog Rotary Shutoff fluid couplings. The CSRM can be used also with less forgiving connectors, as was demonstrated in the lab. The CSRM is NASA-Goddard exclusive design with patent applied for. The CSRM is the correct mechanism for the PIA/SIA interface as well as other similar berthing interfaces.

  16. Connector design in a long-span-fixed dental prosthesis: a three-dimensional finite element analysis.

    PubMed

    Harshitha Gowda, B H; Satish Babu, C L

    2013-01-01

    The goal of every prosthetic management is to simulate nature and be in harmony with nature within the physiological limits. The occlusal forces on a fixed dental prosthesis are transmitted to the surrounding structures through pontics, connectors and retainers and more stresses are seen at the connector region. To analyze the stress patterns in cast and soldered connectors between the two pontics and between the retainer and pontic of a four unit fixed dental prosthesis on axial and non axial loading and also to observe and ascertain the need to modify the design of the rigid connectors. Subsequently four models each of cast and soldered connectors with cylindrical and triangular design, of dimension 3 × 4 mm and thickness 0.5 mm was designed for the study. The first premolar and second molar were considered as the abutments and 2 nd premolar and 1 st molar as the pontics. The analysis was done using ANSYS version 8.0 software and by placing axial and non-axial load of 40 Newtons each. Von Misses stresses were observed at the connector region between the two pontics, especially in the cervical region. The cylindrical cast connectors showed less stress in comparison to triangular design and the difference in the stress distribution of cast and soldered connectors were marginal. The occlusal forces on a fixed dental prosthesis are transmitted to the surrounding structures through pontics, connectors and retainers with maximum stresses concentrated at the connectors. Hence this three-dimensional finite element analysis study investigated stress distribution in a four unit posterior fixed dental prosthesis, having cylindrical and triangular connector designs.

  17. Ultra-Compact Motor Controller

    NASA Technical Reports Server (NTRS)

    Townsend, William T.; Crowell, Adam; Hauptman, Traveler; Pratt, Gill Andrews

    2012-01-01

    This invention is an electronically commutated brushless motor controller that incorporates Hall-array sensing in a small, 42-gram package that provides 4096 absolute counts per motor revolution position sensing. The unit is the size of a miniature hockey puck, and is a 44-pin male connector that provides many I/O channels, including CANbus, RS-232 communications, general-purpose analog and digital I/O (GPIO), analog and digital Hall inputs, DC power input (18-90 VDC, 0-l0 A), three-phase motor outputs, and a strain gauge amplifier. This controller replaces air cooling with conduction cooling via a high-thermal-conductivity epoxy casting. A secondary advantage of the relatively good heat conductivity that comes with ultra-small size is that temperature differences within the controller become smaller, so that it is easier to measure the hottest temperature in the controller with fewer temperature sensors, or even one temperature sensor. Another size-sensitive design feature is in the approach to electrical noise immunity. At a very small size, where conduction paths are much shorter than in conventional designs, the ground becomes essentially isopotential, and so certain (space-consuming) electrical noise control components become unnecessary, which helps make small size possible. One winding-current sensor, applied to all of the windings in fast sequence, is smaller and wastes less power than the two or more sensors conventionally used to sense and control winding currents. An unexpected benefit of using only one current sensor is that it actually improves the precision of current control by using the "same" sensors to read each of the three phases. Folding the encoder directly into the controller electronics eliminates a great deal of redundant electronics, packaging, connectors, and hook-up wiring. The reduction of wires and connectors subtracts substantial bulk and eliminates their role in behaving as EMI (electro-magnetic interference) antennas. A shared knowledge by each motor controller of the state of all the motors in the system at 500 Hz also allows parallel processing of higher-level kinematic matrix calculations.

  18. A novel approach to fabricate silk nanofibers containing hydroxyapatite nanoparticles using a three-way stopcock connector

    NASA Astrophysics Data System (ADS)

    Sheikh, Faheem A.; Ju, Hyung Woo; Moon, Bo Mi; Park, Hyun Jung; Kim, Jung Ho; Lee, Ok Joo; Park, Chan Hum

    2013-07-01

    Electrospinning technique is commonly used to produce micro- and/or nanofibers, which utilizes electrical forces to produce polymeric fibers with diameters ranging from several micrometers down to few nanometers. Desirably, electrospun materials provide highly porous structure and appropriate pore size for initial cell attachment and proliferation and thereby enable the exchange of nutrients. Composite nanofibers consisting of silk and hydroxyapatite nanoparticles (HAp) (NPs) had been considered as an excellent choice due to their efficient biocompatibility and bone-mimicking properties. To prepare these nanofiber composites, it requires the use of acidic solutions which have serious consequences on the nature of both silk and HAp NPs. It is ideal to create these nanofibers using aqueous solutions in which the physicochemical nature of both materials can be retained. However, to create those nanofibers is often difficult to obtain because of the fact that aqueous solutions of silk and HAp NPs can precipitate before they can be ejected into fibers during the electrospinning process. In this work, we had successfully used a three-way stopcock connector to mix the two different solutions, and very shortly, this solution is ejected out to form nanofibers due to electric fields. Different blend ratios consisting HAp NPs had been electrospun into nanofibers. The physicochemical aspects of fabricated nanofiber had been characterized by different state of techniques like that of FE-SEM, EDS, TEM, TEM-EDS, TGA, FT-IR, and XRD. These characterization techniques revealed that HAp NPs can be easily introduced in silk nanofibers using a stopcock connector, and this method favorably preserves the intact nature of silk fibroin and HAp NPs. Moreover, nanofibers obtained by this strategy were tested for cell toxicity and cell attachment studies using NIH 3 T3 fibroblasts which indicated non-toxic behavior and good attachment of cells upon incubation in the presence of nanofibers.

  19. Effects of longitudinal speed reduction markings on left-turn direct connectors.

    PubMed

    Zhao, Xiaohua; Ding, Han; Lin, Zhanzhou; Ma, Jianming; Rong, Jian

    2018-06-01

    Longitudinal speed reduction markings (LSRMs) are designed to alert drivers to an upcoming change in roadway geometry (e.g. direct connectors with smaller radii). In Beijing, LSRMs are usually installed on direct connectors of urban expressways. The objective of this paper is to examine the influence of LSRMs on vehicle operation and driver behavior, and evaluate the decelerating effectiveness of LSRMs on direct connectors with different radii. Empirical data were collected in a driving simulator, and indicators representing vehicle operation status and driving behavior were proposed. To examine the influence of LSRMs, an analysis segment was defined, which begins 500 m prior to the entering point of the connector and ends at the exiting point of the connector. Furthermore, the analysis segment was evenly divided into a series of subsections; the length of each subsection is 50 m. This definition is introduced based on the assumption that drivers would decelerate smoothly in advance of the connector. The analysis results show that drivers tend to decelerate earlier when the radii were 200 m or 300 m. When approaching the connector, drivers tend to decelerate at 500 m thru 250 m in advance of the connector with a 200 m radius; deceleration happens at 300 m-0 m in advance of the connector with a 300 m radius. On the connector, drivers controlled the throttle pedal use at 100 thru 300 m after the entering point when the radius was 200 m; deceleration occurred in two regions when the radius was 300 m: 0 m-900 m from the entering point, and the last 1,000 m of the connector. The analytical results further revealed that LSRMs would be effective at reducing speeds when the radius of the direct connector was 300 m. Copyright © 2018. Published by Elsevier Ltd.

  20. Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors

    PubMed Central

    Tahmasbi, Farzad; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N. H.; Tahir, M. M.

    2016-01-01

    This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using this nonlinear model are performed to investigate the variations in concrete strength and connector dimensions. The finite element analyses also confirm the test results that increasing the length of shear connector increases their shear strength proportionately. It is observed that the maximum stress in L-shaped angle connectors takes place in the weld attachment to the beam, whereas in the C-shaped angle connectors, it is in the attached leg. The location of maximum concrete compressive damage is rendered in each case. Finally, a new equation for prediction of the shear capacity of C-shaped angle connectors is proposed. PMID:27478894

  1. Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors.

    PubMed

    Tahmasbi, Farzad; Maleki, Shervin; Shariati, Mahdi; Ramli Sulong, N H; Tahir, M M

    2016-01-01

    This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using this nonlinear model are performed to investigate the variations in concrete strength and connector dimensions. The finite element analyses also confirm the test results that increasing the length of shear connector increases their shear strength proportionately. It is observed that the maximum stress in L-shaped angle connectors takes place in the weld attachment to the beam, whereas in the C-shaped angle connectors, it is in the attached leg. The location of maximum concrete compressive damage is rendered in each case. Finally, a new equation for prediction of the shear capacity of C-shaped angle connectors is proposed.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Junxing; Yang, Fei, E-mail: yfei2007@mail.xjtu.edu.cn; Luo, Kaiyu

    Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigatemore » the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.« less

  3. METRRA Producibility Investigation

    DTIC Science & Technology

    1975-06-01

    diffusion disappears and all current becomes a drift current under an electric field. Because the charge injected into the p region is not 4...by the tube nonlinearity is about 50dBm below the carrier. The cavity terminates with an SMA connector which is treated as a cylindrical structure...can be neglected owhn compared to the +13dBm produced by the tube itself. This fact implies that there is no need for special treatment or design from

  4. Hand tools: A compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A selection of new hand tools, modifications of existing tools, and techniques developed in the course of NASA research and development projects are presented. The items are presented in two sections: tools for cable and connector applications, and tools for welding applications. Safety is emphasized, together with ease of operation and use in restricted areas or hazardous environments. The discussions are directed primarily toward the technician engaged in assembly or maintenance of mechanical or electrical equipment.

  5. Peripheral controllers and devices--Part 1.

    PubMed

    Pinkert, J R; Wear, L L

    1992-10-01

    In this article, we looked at several peripherals, described their characteristics, and described how they are connected to computers. We included some discussions of problems caused by electrical and mechanical differences between computers and peripheral devices. During the past few years, many companies have addressed such problems. Numerous standards have been defined as a result of this work. These standards specify everything from what type of connectors will be used to the timing of electrical signals. They make it easier for peripheral manufacturers to design their devices for a wide range of computers. Peripherals and their controllers are important components of any computer system. Sometimes, however, other parts of the system, such as the control unit and main memory, receive more attention. Many engineers want to design new processors, but shy away from the design of peripherals and controllers; they consider such designs less glamorous. In reality, designs for some peripherals and their controllers can be more challenging than the design of the CPU itself. A computer without peripherals is of little use, other than as a paper weight. Until we attach peripherals to the computer, none of its power is accessible to the user. Peripherals turn computers into useful tools.

  6. Practical Aspects of Access Network Indoor Extensions Using Multimode Glass and Plastic Optical Fibers

    NASA Astrophysics Data System (ADS)

    Keiser, Gerd; Liu, Hao-Yu; Lu, Shao-Hsi; Devi Pukhrambam, Puspa

    2012-07-01

    Low-cost multimode glass and plastic optical fibers are attractive for high-capacity indoor telecom networks. Many existing buildings already have glass multimode fibers installed for local area network applications. Future indoor applications will use combinations of glass multimode fibers with plastic optical fibers that have low losses in the 850-nm-1,310-nm range. This article examines real-world link losses when randomly interconnecting glass and plastic fiber segments having factory-installed connectors. Potential interconnection issues include large variations in connector losses among randomly selected fiber segments, asymmetric link losses in bidirectional links, and variations in bandwidths among different types of fibers.

  7. KSC-97PC1092

    NASA Image and Video Library

    1997-07-19

    Jet Propulsion Laboratory (JPL) worker Mary Reaves mates connectors on a radioisotope thermoelectric generator (RTG) to power up the Cassini spacecraft, while quality assurance engineer Peter Sorci looks on. The three RTGs which will be used on Cassini are undergoing mechanical and electrical verification testing in the Payload Hazardous Servicing Facility. The RTGs will provide electrical power to Cassini on its 6.7-year trip to the Saturnian system and during its four-year mission at Saturn. RTGs use heat from the natural decay of plutonium to generate electric power. The generators enable spacecraft to operate at great distances from the Sun where solar power systems are not feasible. The Cassini mission is targeted for an Oct. 6 launch aboard a Titan IVB/Centaur expendable launch vehicle. Cassini is built and managed by JPL

  8. Lid heater for glass melter

    DOEpatents

    Phillips, Terrance D.

    1993-01-01

    A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes.

  9. Lid heater for glass melter

    DOEpatents

    Phillips, T.D.

    1993-12-14

    A glass melter having a lid electrode for heating the glass melt radiantly. The electrode comprises a series of INCONEL 690 tubes running above the melt across the melter interior and through the melter walls and having nickel cores inside the tubes beginning where the tubes leave the melter interior and nickel connectors to connect the tubes electrically in series. An applied voltage causes the tubes to generate heat of electrical resistance for melting frit injected onto the melt. The cores limit heat generated as the current passes through the walls of the melter. Nickel bus connection to the electrical power supply minimizes heat transfer away from the melter that would occur if standard copper or water-cooled copper connections were used between the supply and the INCONEL 690 heating tubes. 3 figures.

  10. Heat-shrink plastic tubing seals joints in glass tubing

    NASA Technical Reports Server (NTRS)

    Del Duca, B.; Downey, A.

    1968-01-01

    Small units of standard glass apparatus held together by short lengths of transparent heat-shrinkable polyolefin tubing. The tubing is shrunk over glass O-ring type connectors having O-rings but no lubricant.

  11. Low-loss pigtail reflector for fiber lasers.

    PubMed

    Masuda, Taizo; Iyoda, Mitsuhiro; Yasumatsu, Yuta; Endo, Masamori

    2017-05-01

    We demonstrate a low-loss pigtail reflector for a fiber laser comprising off-the-shelf components. A pigtail configuration has the advantage of easy alteration of the reflection properties, which is highly desired for basic studies and metrological applications. Our proposed reflector consists of a dielectric-coated bulk mirror and an Ferrule connector (FC)-type fiber receptacle, which are fixed with a machined holder such that the FC-type connector at the fiber end can be attached onto the mirror surface with an appropriate amount of pressure, which is essential for minimal reflection loss. The measured reflection loss is 0.07 dB, which is one order of magnitude less than that of the typical connection loss, 0.52 dB, of an FC-FC interconnection; it is comparable to the typical splice loss of a single-mode fiber (0.05 dB). The benefit of the proposed method is its versatility that enables its application to various types of fiber lasers.

  12. Rotary electrical contact device and method for providing current to and/or from a rotating member

    DOEpatents

    Koplow, Jeffrey P

    2013-11-19

    Examples of rotary electrical connectors include a first pair and a second pair of opposing sheaves coupled together by intersecting first shaft connecting the first pair of opposing sheaves and a second shaft connecting the second pair of opposing sheaves, and at least partially electrically conductive belt disposed about respective perimeters of the first pair and second pair of opposing sheaves and adapted to remain in contact with at least a portion of the respective perimeters of the sheaves during motion of said sheaves. In example devices, one of the plurality of sheaves may remain stationary during operation of the device while the remaining sheaves rotate and/or orbit around a center axis of the stationary sheave, the device being configured to couple current between a stationary power source and a rotating member through the electrically conductive belt.

  13. Charge splitters and charge transport junctions based on guanine quadruplexes

    NASA Astrophysics Data System (ADS)

    Sha, Ruojie; Xiang, Limin; Liu, Chaoren; Balaeff, Alexander; Zhang, Yuqi; Zhang, Peng; Li, Yueqi; Beratan, David N.; Tao, Nongjian; Seeman, Nadrian C.

    2018-04-01

    Self-assembling circuit elements, such as current splitters or combiners at the molecular scale, require the design of building blocks with three or more terminals. A promising material for such building blocks is DNA, wherein multiple strands can self-assemble into multi-ended junctions, and nucleobase stacks can transport charge over long distances. However, nucleobase stacking is often disrupted at junction points, hindering electric charge transport between the two terminals of the junction. Here, we show that a guanine-quadruplex (G4) motif can be used as a connector element for a multi-ended DNA junction. By attaching specific terminal groups to the motif, we demonstrate that charges can enter the structure from one terminal at one end of a three-way G4 motif, and can exit from one of two terminals at the other end with minimal carrier transport attenuation. Moreover, we study four-way G4 junction structures by performing theoretical calculations to assist in the design and optimization of these connectors.

  14. Coaxial cable connector

    NASA Technical Reports Server (NTRS)

    Caro, Edward R. (Inventor); Bonazza, Walter J. (Inventor)

    1987-01-01

    A coaxial cable connector is provided, which resists radio frequency breakdown in coaxial cables used in the vacuum of outer space. The connector body surrounds an insulator which includes an easily compressible elastomeric portion. An insulated coaxial cable is prepared so that its insulation projects beyond the outer conductor and compresses the elastomeric portion of the connector insulator.

  15. 76 FR 68504 - Advisory Opinion Proceeding; Certain Coaxial Cable Connectors and Components Thereof and Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-04

    ... Coaxial Cable Connectors and Components Thereof and Products Containing Same; Determination To Institute... coaxial cable connectors and components thereof and products containing the same by reason of infringement... under Commission Rule 210.79 (19 CFR 210.79) that would declare that its coaxial cable connectors...

  16. Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.

    PubMed

    Gan, Ning; Ruan, Yaye; Sun, Jian; Xiong, Yaoyang; Jiao, Ting

    2018-01-11

    The objective was to compare the adaptation between the major connectors of removable partial dentures derived from intraoral digital impressions and extraoral digital impressions. Twenty-four volunteers were enrolled. Each volunteer received an intraoral digital impression and one extraoral digital impression digitized from conventional gypsum impression. A software was used to create the major connectors on digital impression datasets. After all the virtual major connectors designed from Group intraoral digital impressions (Group I) and Group extraoral digital impressions (Group E) were directly fabricated by 3D printing technique, the adaptation of the final major connectors in volunteers' mouths were measured. The adaptation ranged from 159.87 to 577.99 μm in Group I while from 120.83 to 536.17 μm in Group E. The adaptation of major connectors in Group I were found better at the midline palatine suture while the adaptation of major connectors in Group E were found better at the two sides of the palatal vault. In both groups, the highest accuracy in adaptation was revealed at the anterior margin of the major connectors. It is feasible to manufacture the major connectors by digital impression and 3D printing technique. Both the adaptation of the two kinds of digital impressions were clinical acceptable.

  17. United States Air Force Summer Faculty Research Program. 1985 Technical Report. Volume 2.

    DTIC Science & Technology

    1985-12-01

    Voluntary Hand Grip Torque for Dr. Samuel Adams Circular Electrical Connectors 3 Properties and Processing of a Dr. Vernon R. Allen Perfluorinated ...Neutral Particle Beam at Low Energies in the Mark I Aerospace Chamber 126 Preparation of Non-Flammable Model Dr. Terrill D. Smith Compounds 127 Studies on...Synthesis of Azo Compounds F xi 140 A Comparison of Measured and Calculated Dr. Larry Vardiman Attenuation of 28 GHZ Beacon Signals in Three California

  18. Piezoelectric Micro- and Nanostructured Fibers Fabricated from Thermoplastic Nanocomposites Using a Fiber Drawing Technique: Comparative Study and Potential Applications.

    PubMed

    Lu, Xin; Qu, Hang; Skorobogatiy, Maksim

    2017-02-28

    We report an all-polymer flexible piezoelectric fiber that uses both judiciously chosen geometry and advanced materials in order to enhance fiber piezoelectric response. The microstructured/nanostructured fiber features a soft hollow polycarbonate core surrounded by a spiral multilayer cladding consisting of alternating layers of piezoelectric nanocomposites (polyvinylidene enhanced with BaTiO 3 , PZT, or CNT) and conductive polymer (carbon-filled polyethylene). The conductive polymer layers serve as two electrodes, and they also form two spatially offset electric connectors on the fiber surface designed for the ease of connectorization. Kilometer-long piezoelectric fibers of sub-millimeter diameters are thermally drawn from a macroscopic preform. The fibers exhibit high output voltage of up to 6 V under moderate bending, and they show excellent mechanical and electrical durability in a cyclic bend-release test. The micron/nanosize multilayer structure enhances in-fiber poling efficiency due to the small distance between the conducting electrodes sandwiching the piezoelectric composite layers. Additionally, the spiral structure greatly increases the active area of the piezoelectric composite, thus promoting higher voltage generation and resulting in 10-100 higher power generation efficiency over the existing piezoelectric cables. Finally, we weave the fabricated piezoelectric fibers into technical textiles and demonstrate their potential applications in power generation when used as a sound detector, smart car seat upholstery, or wearable materials.

  19. Connector For Embedded Optical Fiber

    NASA Technical Reports Server (NTRS)

    Wilkerson, Charles; Hiles, Steven; Houghton, J. Richard; Holland, Brent W.

    1994-01-01

    Partly embedded fixture is simpler and sturdier than other types of outlets for optical fibers embedded in solid structures. No need to align coupling prism and lenses. Fixture includes base, tube bent at 45 degree angle, and ceramic ferrule.

  20. Effect on de-greasing solvents on conductive separable connector shields and semiconductive cable shields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perry, D.D.; Bolcar, J.P.

    1990-04-01

    A study has been conducted to determine the effects of commercial degreasing solvents on the conductivity of an EPDM separable connector shield and two types of cable shields based on EPR and XLPE, respectively. Solvents tested included a chlorinated solvent based on 1,1,1-trichloroethane and several so-called citrus solvents consisting of the natural terpene, limonene, or blends of limonene with other hydrocarbons. All the solvents significantly degraded the conductivity of the EPR and EPDM materials, but had little effect on the XLPE cable shield. The solvents differed, however, in the extent of their effects, the rate of recovery of conductivity aftermore » removal of the solvent, and the degree to which the original conductivity of the material was restored. The consequences of these results in terms of appropriate field use of these types of solvents by utility personnel are discussed.« less

  1. 77 FR 48138 - Notice of Intent To Prepare an Environmental Impact Statement for the Planned Jordan Cove...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... No. PF12-7-000: Pacific Connector Gas Pipeline LP--Docket No. PF12-17-000] Notice of Intent To..., Oregon, and Pacific Connector Gas Pipeline LP's (Pacific Connector) proposed pipeline project crossing... gas (LNG) terminal is in the public interest, and whether the Pacific Connector pipeline is in the...

  2. Beam connector apparatus and assembly

    NASA Technical Reports Server (NTRS)

    Vontiesenhausen, G. F. (Inventor)

    1983-01-01

    An apparatus and assembly for connecting beams and like structural members is disclosed which is particularly advantageous for connecting two members which are moved laterally into place. The connector apparatus requires no relative longitudinal movement between the ends of the beams or members being connected to make a connection joint. The apparatus includes a receptacle member and a connector housing carried by opposed ends of the structural member being connected. A spring-loaded connector member is carried by the connector housing which may be released for extension and engagement into the receptacle member.

  3. Single mode fiber and twin-core fiber connection technique for in-fiber integrated interferometer

    NASA Astrophysics Data System (ADS)

    Yuan, Tingting; Zhang, Xiaotong; Guan, Chunying; Yang, Xinghua; Yuan, Libo

    2015-09-01

    A novel twin-core fiber connector has been made by two side-polished fibers. By using side polishing technique, we present a connector based on the twin-core fiber (TCF) and two D-shaped single-core fibers. After simple alignment and splicing, all fiber miniaturizing connector can be obtained. Two cores can operate independently and are non-interfering. The coupling loss of this connector is low and the fabrication technologies are mature. The connector device could be used for sensors or particle trapping.

  4. Metal Patch Antenna

    NASA Technical Reports Server (NTRS)

    Chamberlain, Neil F. (Inventor); Zawadzki, Mark S. (Inventor); Hodges, Richard E. (Inventor)

    2012-01-01

    Disclosed herein is a patch antenna comprises a planar conductive patch attached to a ground plane by a support member, and a probe connector in electrical communication with the conductive patch arranged to conduct electromagnetic energy to or from the conductive patch, wherein the conductive patch is disposed essentially parallel to the ground plane and is separated from the ground plane by a spacing distance; wherein the support member comprises a plurality of sides disposed about a central axis oriented perpendicular to the conductive patch and the ground plane; wherein the conductive patch is solely supported above the ground plane by the support member; and wherein the support member provides electrical communication between the planer conductive patch and the ground plane.

  5. High resolution, low cost solar cell contact development

    NASA Technical Reports Server (NTRS)

    Mardesich, N.

    1981-01-01

    The MIDFILM cell fabrication and encapsulation processes were demonstrated as a means of applying low-cost solar cell collector metallization. The average cell efficiency of 12.0 percent (AM1, 28 C) was achieved with fritted silver metallization with a demonstration run of 500 starting wafers. A 98 percent mechanical yield and 80 percent electrical yield were achieved through the MIDFILM process. High series resistance was responsible for over 90 percent of the electrical failures and was the major factor causing the low average cell efficiency. Environmental evaluations suggest that the MIDFILM cells do not degrade. A slight degradation in power was experienced in the MIDFILM minimodules when the AMP Solarlok connector delaminated during the environmental testing.

  6. Study on the influence of step changed spacing of shear stud connector on the behavior of continuous composite beams

    NASA Astrophysics Data System (ADS)

    Luo, Yong; Zhou, Dong Hua; Duan, Bin

    2018-05-01

    In practice, in the steel-concrete composite continuous beam, the shear stud connectors with step changed spacing are often used: How are the slip, deflection and the shear stud connector forces influenced by the step changed spacing of studs connectors? For this question, it will be discussed in the text.

  7. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a... at pumps, valves, and connectors in heavy liquid service and pressure relief devices in light liquid...

  8. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a... at pumps, valves, and connectors in heavy liquid service and pressure relief devices in light liquid...

  9. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a... at pumps, valves, and connectors in heavy liquid service and pressure relief devices in light liquid...

  10. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a... at pumps, valves, and connectors in heavy liquid service and pressure relief devices in light liquid...

  11. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a... at pumps, valves, and connectors in heavy liquid service and pressure relief devices in light liquid...

  12. 40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Connectors in gas and vapor service...

  13. 40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor...

  14. 40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor...

  15. 40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor...

  16. 40 CFR 63.649 - Alternative means of emission limitation: Connectors in gas/vapor service and light liquid service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...

  17. 40 CFR 63.649 - Alternative means of emission limitation: Connectors in gas/vapor service and light liquid service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...

  18. 40 CFR 63.649 - Alternative means of emission limitation: Connectors in gas/vapor service and light liquid service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...

  19. 40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Connectors in gas and vapor service...

  20. 40 CFR 63.649 - Alternative means of emission limitation: Connectors in gas/vapor service and light liquid service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...

  1. 40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Connectors in gas and vapor service...

  2. 40 CFR 63.649 - Alternative means of emission limitation: Connectors in gas/vapor service and light liquid service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... limitation: Connectors in gas/vapor service and light liquid service. 63.649 Section 63.649 Protection of...: Connectors in gas/vapor service and light liquid service. (a) If an owner or operator elects to monitor... gas/vapor service and for connectors in light liquid service. The data for the two groups of...

  3. 40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor...

  4. 40 CFR 60.482-11a - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-11a Standards: Connectors in gas/vapor service and in light liquid service. (a) The owner or operator... connectors in gas and vapor and light liquid service as specified in paragraphs (a) and (b)(3) of this... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor...

  5. 40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Connectors in gas and vapor service...

  6. 40 CFR 63.1027 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards § 63.1027 Connectors in gas and vapor service and in light liquid service standards. (a..., the owner or operator shall monitor all connectors in gas and vapor and light liquid service as... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Connectors in gas and vapor service...

  7. Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes

    NASA Technical Reports Server (NTRS)

    Pontius, James; McGuffey, Douglas

    2011-01-01

    A connector retainer and mounting system has been designed to replace screw-mounting of Winchester connectors. Countersunk screws are normally used to secure connectors to structures, and to keep them from coming apart. These screws are normally put into threaded or through-holes in metallic structures. This unique retainer is designed such that integral posts keep the connector halves retained, and a groove permits a cable tie to be fastened around the retainer and composite tube, thus securing the connector to the structure. The system is compatible for use on cryogenic (and conventional) bonded composite tube assemblies. Screws and tapped/through-holes needed to retain and mount Winchester connectors cannot be used on blind-access composite tubes. This system allows for rapid installation, removal, low-molecular-outgassing materials, and particulate-free installation and removal. Installation and/or changes late in the integration, and test flow with limited access in a cleanroom environment are possible. No sanding or bonding is needed.

  8. Microfluidic interconnects

    DOEpatents

    Benett, William J.; Krulevitch, Peter A.

    2001-01-01

    A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.

  9. Solar cell shingle

    NASA Technical Reports Server (NTRS)

    Forestieri, A. F.; Ratajczak, A. F.; Sidorak, L. G. (Inventor)

    1977-01-01

    A solar cell shingle was made of an array of solar cells on a lower portion of a substantially rectangular shingle substrate made of fiberglass cloth or the like. The solar cells may be encapsulated in flourinated ethylene propylene or some other weatherproof translucent or transparent encapsulant to form a combined electrical module and a roof shingle. The interconnected solar cells were connected to connectors at the edge of the substrate through a connection to a common electrical bus or busses. An overlap area was arranged to receive the overlap of a cooperating similar shingle so that the cell portion of the cooperating shingle may overlie the overlap area of the roof shingle. Accordingly, the same shingle serves the double function of an ordinary roof shingle which may be applied in the usual way and an array of cooperating solar cells from which electrical energy may be collected.

  10. Practical aspects of instrumentation system installation, volume 13

    NASA Technical Reports Server (NTRS)

    Borek, R. W.; Pool, A. (Editor); Sanderson, K. C. (Editor)

    1981-01-01

    A review of factors influencing installation of aircraft flight test instrumentation is presented. Requirements, including such factors as environment, reliability, maintainability, and system safety are discussed. The assessment of the mission profile is followed by an overview of electrical and mechanical installation factors with emphasis on shock/vibration isolation systems and standardization of the electric wiring installation, two factors often overlooked by instrumentation engineers. A discussion of installation hardware reviews the performance capabilities of wiring, connectors, fuses and circuit breakers, and a guide to proper selections is provided. The discussion of the installation is primarily concerned with the electrical wire routing, shield terminations and grounding. Also inclued are some examples of installation mistakes that could affect system accuracy. System verification procedures and special considerations such as sneak circuits, pyrotechnics, aircraft antenna patterns, and lightning strikes are discussed.

  11. Multiple-layer printed-wiring trace connector

    NASA Technical Reports Server (NTRS)

    Pizzeck, D. E.

    1977-01-01

    Nickel-plated spring-steel foil connector is hollow pin, with lengthwise slit, that is inserted into improperly plated-through holes. Edges of connector make positive contact with copper pads within hole.

  12. Behaviour of partially composite precast concrete sandwich panels under flexural and axial loads

    NASA Astrophysics Data System (ADS)

    Tomlinson, Douglas George

    Precast concrete sandwich panels are commonly used on building exteriors. They are typically composed of two concrete wythes that surround rigid insulation. They are advantageous as they provide both structural and thermal resistance. The structural response of sandwich panels is heavily influenced by shear connectors that link the wythes together. This thesis presents a study on partially composite non-prestressed precast concrete wall panels. Nine flexure tests were conducted on a wall design incorporating 'floating' concrete studs and Glass Fibre Reinforced Polymer (GFRP) connectors. The studs encapsulate and stiffen the connectors, reducing shear deformations. Ultimate loads increased from 58 to 80% that of a composite section as the connectors' reinforcement ratio increased from 2.6 to 9.8%. This design was optimized by reinforcing the studs and integrating them with the structural wythe; new connectors composed of angled steel or Basalt-FRP (BFRP) were used. The load-slip response of the new connector design was studied through 38 double shear push-through tests using various connector diameters and insertion angles. Larger connectors were stronger but more likely to pull out. Seven flexure tests were conducted on the new wall design reinforced with different combinations of steel and BFRP connectors and reinforcement. Composite action varied from 50 to 90% depending on connector and reinforcement material. Following this study, the axial-bending interaction curves were established for the new wall design using both BFRP and steel connectors and reinforcement. Eight panels were axially loaded to predesignated loads then loaded in flexure to failure. A technique is presented to experimentally determine the effective centroid of partially composite sections. Beyond the tension and compression-controlled failure regions of the interaction curve, a third region was observed in between, governed by connector failure. Theoretical models were developed for the bond-slip behaviour of the shear connection and to analyze the full panel's flexural and axial response to determine the longitudinal shear force transferred between wythes and account for partial composite behavior. The models were validated against experiments and used to conduct a parametric study. Among several interesting findings, the study demonstrated how composite action increases with the slenderness of axially loaded panels.

  13. Lightning arrestor connector lead magnesium niobate qualification pellet test procedures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuohig, W.; Mahoney, Patrick A.; Tuttle, Bruce Andrew

    2009-02-01

    Enhanced knowledge preservation for DOE DP technical component activities has recently received much attention. As part of this recent knowledge preservation effort, improved documentation of the sample preparation and electrical testing procedures for lead magnesium niobate--lead titanate (PMN/PT) qualification pellets was completed. The qualification pellets are fabricated from the same parent powders used to produce PMN/PT lightning arrestor connector (LAC) granules at HWF&T. In our report, the procedures for fired pellet surface preparation, electrode deposition, electrical testing and data recording are described. The dielectric measurements described in our report are an information only test. Technical reasons for selecting the electrodemore » material, electrode size and geometry are presented. The electrical testing is based on measuring the dielectric constant and dissipation factor of the pellet during cooling from 280 C to 220 C. The most important data are the temperature for which the peak dielectric constant occurs (Curie Point temperature) and the peak dielectric constant magnitude. We determined that the peak dielectric constant for our procedure would be that measured at 1 kHz at the Curie Point. Both the peak dielectric constant and the Curie point parameters provide semi-quantitative information concerning the chemical and microstructural homogeneity of the parent material used for the production of PMN/PT granules for LACs. Finally, we have proposed flag limits for the dielectric data for the pellets. Specifically, if the temperature of the peak dielectric constant falls outside the range of 250 C {+-} 30 C we propose that a flag limit be imposed that will initiate communication between production agency and design agency personnel. If the peak dielectric constant measured falls outside the range 25,000 {+-} 10,000 we also propose that a flag limit be imposed.« less

  14. The Crystal Structure of Bacteriophage HK97 gp6: Defining a Large Family of Head-Tail Connector Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardarelli, Lia; Lam, Robert; Tuite, Ashleigh

    2010-08-17

    The final step in the morphogenesis of long-tailed double-stranded DNA bacteriophages is the joining of the DNA-filled head to the tail. The connector is a specialized structure of the head that serves as the interface for tail attachment and the point of egress for DNA from the head during infection. Here, we report the determination of a 2.1 {angstrom} crystal structure of gp6 of bacteriophage HK97. Through structural comparisons, functional studies, and bioinformatic analysis, gp6 has been determined to be a component of the connector of phage HK97 that is evolutionarily related to gp15, a well-characterized connector component of bacteriophagemore » SPP1. Whereas the structure of gp15 was solved in a monomeric form, gp6 crystallized as an oligomeric ring with the dimensions expected for a connector protein. Although this ring is composed of 13 subunits, which does not match the symmetry of the connector within the phage, sequence conservation and modeling of this structure into the cryo-electron microscopy density of the SPP1 connector indicate that this oligomeric structure represents the arrangement of gp6 subunits within the mature phage particle. Through sequence searches and genomic position analysis, we determined that gp6 is a member of a large family of connector proteins that are present in long-tailed phages. We have also identified gp7 of HK97 as a homologue of gp16 of phage SPP1, which is the second component of the connector of this phage. These proteins are members of another large protein family involved in connector assembly.« less

  15. The Crystal Structure of Bacteriophage HK97 gp6: Defining a Large Family of Head-Tail Connector Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardarelli, Lia; Lam, Robert; Tuite, Ashleigh

    2011-11-23

    The final step in the morphogenesis of long-tailed double-stranded DNA bacteriophages is the joining of the DNA-filled head to the tail. The connector is a specialized structure of the head that serves as the interface for tail attachment and the point of egress for DNA from the head during infection. Here, we report the determination of a 2.1 Å crystal structure of gp6 of bacteriophage HK97. Through structural comparisons, functional studies, and bioinformatic analysis, gp6 has been determined to be a component of the connector of phage HK97 that is evolutionarily related to gp15, a well-characterized connector component of bacteriophagemore » SPP1. Whereas the structure of gp15 was solved in a monomeric form, gp6 crystallized as an oligomeric ring with the dimensions expected for a connector protein. Although this ring is composed of 13 subunits, which does not match the symmetry of the connector within the phage, sequence conservation and modeling of this structure into the cryo-electron microscopy density of the SPP1 connector indicate that this oligomeric structure represents the arrangement of gp6 subunits within the mature phage particle. Through sequence searches and genomic position analysis, we determined that gp6 is a member of a large family of connector proteins that are present in long-tailed phages. We have also identified gp7 of HK97 as a homologue of gp16 of phage SPP1, which is the second component of the connector of this phage. These proteins are members of another large protein family involved in connector assembly.« less

  16. Phi29 Connector-DNA Interactions Govern DNA Crunching and Rotation, Supporting the Check-Valve Model

    PubMed Central

    Kumar, Rajendra; Grubmüller, Helmut

    2016-01-01

    During replication of the ϕ29 bacteriophage inside a bacterial host cell, a DNA packaging motor transports the viral DNA into the procapsid against a pressure difference of up to 40 ± 20 atm. Several models have been proposed for the underlying molecular mechanism. Here we have used molecular dynamics simulations to examine the role of the connector part of the motor, and specifically the one-way revolution and the push-roll model. We have focused at the structure and intermolecular interactions between the DNA and the connector, for which a near-complete structure is available. The connector is found to induce considerable DNA deformations with respect to its canonical B-form. We further assessed by force-probe simulations to which extent the connector is able to prevent DNA leakage and found that the connector can act as a partial one-way valve by a check-valve mechanism via its mobile loops. Analysis of the geometry, flexibility, and energetics of channel lysine residues suggested that this arrangement of residues is incompatible with the observed DNA packaging step-size of ∼2.5 bp, such that the step-size is probably determined by the other components of the motor. Previously proposed DNA revolution and rolling motions inside the connector channel are both found implausible due to structural entanglement between the DNA and connector loops that have not been resolved in the crystal structure. Rather, in the simulations, the connector facilitates minor DNA rotation during the packaging process compatible with recent optical-tweezers experiments. Combined with the available experimental data, our simulation results suggest that the connector acts as a check-valve that prevents DNA leakage and induces DNA compression and rotation during DNA packaging. PMID:26789768

  17. Adequate disinfection of a split-septum needleless intravascular connector with a 5-second alcohol scrub.

    PubMed

    Rupp, Mark E; Yu, Stephanie; Huerta, Tomas; Cavalieri, R Jennifer; Alter, Roxanne; Fey, Paul D; Van Schooneveld, Trevor; Anderson, James R

    2012-07-01

    Define optimum vascular catheter connector valve disinfection practices under laboratory and clinical conditions. Prospective observational clinical survey and laboratory assessment of disinfection procedures. All adult inpatients at an academic healthcare center. In the clinical setting, contamination of needleless connectors was assessed in 6 weekly prevalence surveys in which the connector valves from central venous catheters (CVCs) in situ were cultured by pressing the connector diaphragm to an agar plate. Before culture, valves were disinfected by scrubbing the diaphragm with a 70% isopropyl alcohol pledget for 0, 5, 10, 15, or 30 seconds. In the laboratory, the diaphragms on 150 unused sterile connector valves were inoculated with 10(3), 10(5), or 10(8) colony-forming units of Staphylococcus epidermidis and allowed to dry. After disinfection of the diaphragms by scrubbing with a 70% isopropyl alcohol pledget for 0, 5, 10, 15, or 30 seconds, the valves were sampled by pressing the diaphragm to an agar plate. In the clinical setting, 363 connector valves from patients with CVCs were sampled, and 66.7% of nondisinfected valves revealed bacterial contamination. After 5-second disinfection with an alcohol pledget, only 1 (1.4%) of 71 yielded microbial growth (P < .005). In the laboratory, at the 10(3) and 10(5) inoculum, all connector valves yielded sterile cultures when scrubbed for 5 or more seconds (P < .001). At the 10(8) inoculum, 2 (20%) of 10 connector valves yielded minimal growth of S. epidermidis. A 5-second scrub with a 70% isopropyl alcohol pledget yields adequate disinfection of a split-septum intravascular catheter connector valve under clinical and laboratory conditions.

  18. Utilization of low temperatures in electrical machines

    NASA Astrophysics Data System (ADS)

    Kwasniewska-Jankowicz, L.; Mirski, Z.

    1983-09-01

    The dimensions of conventional and superconducting direct and alternating current generators are compared and the advantages of using superconducting magnets are examined. The critical temperature, critical current, and critical magnetic field intensity of superconductors in an induction winding are discussed as well as the mechanical properties needed for bending connectors at small radii. Investigations of cryogenic cooling, cryostats, thermal insulation and rotary seals are reported as well as results of studies of the mechanical properties of austenitic Cr-Ni steels, welded joints and plastics for insulation.

  19. Robots Would Couple And Uncouple Fluid And Electrical Lines

    NASA Technical Reports Server (NTRS)

    Del Castillo, Eduardo Lopez; Davis, Virgil; Ferguson, Bob; Reichle, Garland

    1992-01-01

    Robots make and break connections between umbilical plates and mating connectors on rockets about to be launched. Sensing and control systems include vision, force, and torque subsystems. Enhances safety by making it possible to couple and uncouple umbilical plates quickly, without exposing human technicians to hazards of leaking fuels and oxidizers. Significantly reduces time spent to manually connect umbilicals. Robots based on similar principles used in refueling of National AeroSpace Plane (NASP) and satellites and orbital transfer vehicles in space.

  20. Calorimetry of 25 Ah lithium/thionyl chloride cells

    NASA Technical Reports Server (NTRS)

    Johnson, C. J.; Dawson, S.

    1991-01-01

    Heat flow measurements of 25-Ah lithium thionyl chloride cells provided a method to calculate an effective thermal potential, E(TP) of 3.907 V. The calculation is useful to determine specific heat generation of this cell chemistry and design. The E(TP) value includes heat generation by electrochemical cell reactions, competitive chemical reactions, and resistance heating at the tabs, connectors, and leads. Heat flow was measured while applying electrical loads to the cell in an isothermal calorimeter set at 0, 20, and 60 C.

  1. Ion Source Development for a Compact Proton Beam Writing System III

    DTIC Science & Technology

    2013-06-28

    to yield ion beam with energies up to 3 keV. The electrical power required to operate multiple components (like RF Valve , Probe and Extraction...they are powered through an isolation transformer. The required gas, to be ionized in the RF ion source, is fed through a coarse needle valve ...connector, the system can be pumped down to 3×10-2 mbar using an oil roughing pump. Nitrogen gas is feed in by adjusting the gas regulating valve

  2. Effects of Surface Roughness and Aging on the Electrical Contact Resistance and Residual Stress in Gold-Nickel-Copper Connector Materials

    DTIC Science & Technology

    2014-12-01

    with nickel coatings can result in compressive stresses, and the deposition of gold with small amounts of cobalt increase the coating hardness/wear...magnetic metal. In the literature, there are a few different approaches to allow for the sputter deposition of magnetic materials including: doping ...the target (i.e., nickel doped with vanadium, typically on the order of 7- 9% [19]) to the point that it is no longer magnetic, heating the target

  3. Woven ribbon cable for cryogenic instruments

    NASA Astrophysics Data System (ADS)

    Cunningham, C. R.; Hastings, P. R.; Strachan, J. M. D.

    Robust woven ribbon cables are described for connecting sensors at low temperatures to higher temperature systems. Woven cables have several advantages over conventional wiring or flat ribbon cables in cryostats: heat sinking is easier; twisted pairs may be used; and miniature multi-way connectors are easily incorporated. Their use is demonstrated in making connections from 131 bolometers in two arrays mounted in a dilution refrigerator at 100 mK. Thermal and electrical properties are discussed, as are other possible applications in cryogenic instruments.

  4. Corrosion of connectors used in equipment protecting against falls from a height

    PubMed Central

    Jachowicz, Marcin

    2015-01-01

    Connectors are commonly found in personal equipment protecting against falls from a height. They are typically used outdoors and exposed to atmospheric factors, which can result in corrosion. This article presents the results of a study involving exposure of connectors to experimental corrosive media – neutral salt spray (NSS), acid salt spray (ASS), and seawater mist (for elements made of carbon steel and non-ferrous metals) – and to experimental conditions simulating the processes of pitting, stress, and intercrystalline corrosion (for equipment made of s`tainless steel). The results indicate that the main effects of corrosion on connectors include impaired operation and reduced strength of their mobile elements. The article presents methods of testing connector operation developed for this purpose. Corrosive damage to connectors has been presented in relation to potential hazards for their users. PMID:26647950

  5. KSC-08pd0039

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Mike Berger, with Lockheed Martin, examines the internal connector on space shuttle Atlantis' external tank to which the replacement feed-through connector in the engine cutoff, or ECO, sensor system will be attached. The replacement connector is seen below Berger's hand. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  6. Apparatus for improving performance of electrical insulating structures

    DOEpatents

    Wilson, Michael J.; Goerz, David A.

    2004-08-31

    Removing the electrical field from the internal volume of high-voltage structures; e.g., bushings, connectors, capacitors, and cables. The electrical field is removed from inherently weak regions of the interconnect, such as between the center conductor and the solid dielectric, and places it in the primary insulation. This is accomplished by providing a conductive surface on the inside surface of the principal solid dielectric insulator surrounding the center conductor and connects the center conductor to this conductive surface. The advantage of removing the electric fields from the weaker dielectric region to a stronger area improves reliability, increases component life and operating levels, reduces noise and losses, and allows for a smaller compact design. This electric field control approach is currently possible on many existing products at a modest cost. Several techniques are available to provide the level of electric field control needed. Choosing the optimum technique depends on material, size, and surface accessibility. The simplest deposition method uses a standard electroless plating technique, but other metalization techniques include vapor and energetic deposition, plasma spraying, conductive painting, and other controlled coating methods.

  7. Apparatus for improving performance of electrical insulating structures

    DOEpatents

    Wilson, Michael J.; Goerz, David A.

    2002-01-01

    Removing the electrical field from the internal volume of high-voltage structures; e.g., bushings, connectors, capacitors, and cables. The electrical field is removed from inherently weak regions of the interconnect, such as between the center conductor and the solid dielectric, and places it in the primary insulation. This is accomplished by providing a conductive surface on the inside surface of the principal solid dielectric insulator surrounding the center conductor and connects the center conductor to this conductive surface. The advantage of removing the electric fields from the weaker dielectric region to a stronger area improves reliability, increases component life and operating levels, reduces noise and losses, and allows for a smaller compact design. This electric field control approach is currently possible on many existing products at a modest cost. Several techniques are available to provide the level of electric field control needed. Choosing the optimum technique depends on material, size, and surface accessibility. The simplest deposition method uses a standard electroless plating technique, but other metalization techniques include vapor and energetic deposition, plasma spraying, conductive painting, and other controlled coating methods.

  8. Method for improving performance of highly stressed electrical insulating structures

    DOEpatents

    Wilson, Michael J.; Goerz, David A.

    2002-01-01

    Removing the electrical field from the internal volume of high-voltage structures; e.g., bushings, connectors, capacitors, and cables. The electrical field is removed from inherently weak regions of the interconnect, such as between the center conductor and the solid dielectric, and places it in the primary insulation. This is accomplished by providing a conductive surface on the inside surface of the principal solid dielectric insulator surrounding the center conductor and connects the center conductor to this conductive surface. The advantage of removing the electric fields from the weaker dielectric region to a stronger area improves reliability, increases component life and operating levels, reduces noise and losses, and allows for a smaller compact design. This electric field control approach is currently possible on many existing products at a modest cost. Several techniques are available to provide the level of electric field control needed. Choosing the optimum technique depends on material, size, and surface accessibility. The simplest deposition method uses a standard electroless plating technique, but other metalization techniques include vapor and energetic deposition, plasma spraying, conductive painting, and other controlled coating methods.

  9. Port resilience: overcoming threats to maritime infrastructure and operations from climate change : final report.

    DOT National Transportation Integrated Search

    2015-12-01

    In the coastal zone, seaports and their intermodal connectors are key types of infrastructure that support the global : supply chain, provide regional economic activity, local transportation system services, and community jobs. The : protection of co...

  10. Lunar Module Wiring Design Considerations and Failure Modes

    NASA Technical Reports Server (NTRS)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  11. PCACE- PERSONAL COMPUTER AIDED CABLING ENGINEERING

    NASA Technical Reports Server (NTRS)

    Billitti, J. W.

    1994-01-01

    A computerized interactive harness engineering program has been developed to provide an inexpensive, interactive system which is designed for learning and using an engineering approach to interconnection systems. PCACE is basically a database system that stores information as files of individual connectors and handles wiring information in circuit groups stored as records. This directly emulates the typical manual engineering methods of data handling, thus making the user interface to the program very natural. Data files can be created, viewed, manipulated, or printed in real time. The printed ouput is in a form ready for use by fabrication and engineering personnel. PCACE also contains a wide variety of error-checking routines including connector contact checks during hardcopy generation. The user may edit existing harness data files or create new files. In creating a new file, the user is given the opportunity to insert all the connector and harness boiler plate data which would be part of a normal connector wiring diagram. This data includes the following: 1) connector reference designator, 2) connector part number, 3) backshell part number, 4) cable reference designator, 5) cable part number, 6) drawing revision, 7) relevant notes, 8) standard wire gauge, and 9) maximum circuit count. Any item except the maximum circuit count may be left blank, and any item may be changed at a later time. Once a file is created and organized, the user is directed to the main menu and has access to the file boiler plate, the circuit wiring records, and the wiring records index list. The organization of a file is such that record zero contains the connector/cable boiler plate, and all other records contain circuit wiring data. Each wiring record will handle a circuit with as many as nine wires in the interface. The record stores the circuit name and wire count and the following data for each wire: 1) wire identifier, 2) contact, 3) splice, 4) wire gauge if different from standard, 5) wire/group type, 6) wire destination, and 7) note number. The PCACE record structure allows for a wide variety of wiring forms using splices and shields, yet retains sufficient structure to maintain ease of use. PCACE is written in TURBO Pascal 3.0 and has been implemented on IBM PC, XT, and AT systems under DOS 3.1 with a memory of 512K of 8 bit bytes, two floppy disk drives, an RGB monitor, and a printer with ASCII control characters. PCACE was originally developed in 1983, and the IBM version was released in 1986.

  12. Debris protection cover assembly for cable connectors

    NASA Technical Reports Server (NTRS)

    Yovan, Roger D. (Inventor)

    1999-01-01

    A protective cover assembly for an end of a cable connector having a cable housing that encloses a plurality of connective pins or sockets and that satisfies all requirements for space applications. A connector body flange is formed at the extremity of a cable and is positioned so that it may register with a corresponding connector body flange on the end of a companion cable to which a connection is to be made, one cable end having cable lead pins and the companion cable end having lead sockets with which the pins register. A latch mechanism having a latch housing is received in the connector body flange and a crank connected to a manually rotatable cap actuates a spring-loaded latch element that is engageable with a connector body flange to secure or to release the cover assembly with the simple twisting motion of the cap, thereby simplifying the task of effecting coupling and decoupling of the cable ends.

  13. KSC-07pd3659

    NASA Image and Video Library

    2007-12-29

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician gives the connector a cleaning, removing any residual foam insulation, and begins disconnecting the connector assembly. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  14. The role of extracellular conductivity profiles in compartmental models for neurons: particulars for layer 5 pyramidal cells.

    PubMed

    Wang, Kai; Riera, Jorge; Enjieu-Kadji, Herve; Kawashima, Ryuta

    2013-07-01

    With the rapid increase in the number of technologies aimed at observing electric activity inside the brain, scientists have felt the urge to create proper links between intracellular- and extracellular-based experimental approaches. Biophysical models at both physical scales have been formalized under assumptions that impede the creation of such links. In this work, we address this issue by proposing a multicompartment model that allows the introduction of complex extracellular and intracellular resistivity profiles. This model accounts for the geometrical and electrotonic properties of any type of neuron through the combination of four devices: the integrator, the propagator, the 3D connector, and the collector. In particular, we applied this framework to model the tufted pyramidal cells of layer 5 (PCL5) in the neocortex. Our model was able to reproduce the decay and delay curves of backpropagating action potentials (APs) in this type of cell with better agreement with experimental data. We used the voltage drops of the extracellular resistances at each compartment to approximate the local field potentials generated by a PCL5 located in close proximity to linear microelectrode arrays. Based on the voltage drops produced by backpropagating APs, we were able to estimate the current multipolar moments generated by a PCL5. By adding external current sources in parallel to the extracellular resistances, we were able to create a sensitivity profile of PCL5 to electric current injections from nearby microelectrodes. In our model for PCL5, the kinetics and spatial profile of each ionic current were determined based on a literature survey, and the geometrical properties of these cells were evaluated experimentally. We concluded that the inclusion of the extracellular space in the compartmental models of neurons as an extra electrotonic medium is crucial for the accurate simulation of both the propagation of the electric potentials along the neuronal dendrites and the neuronal reactivity to an electrical stimulation using external microelectrodes.

  15. Thermocouple Extension-Wire-Connections and Low Temperatures

    NASA Technical Reports Server (NTRS)

    Figueroa, Fernando; Mitchell, Mark; Richardson, Gregory

    2000-01-01

    Experiments were carried out to determine the casue of erroneous readings from thermocouples of type K when measuring temperatures of liquid hydrogen. It was believed to be linked to te temperature of the connector used to extend the thermocouple wires to the voltage meter.

  16. Design process of a photonics network for military platforms

    NASA Astrophysics Data System (ADS)

    Nelson, George F.; Rao, Nagarajan M.; Krawczak, John A.; Stevens, Rick C.

    1999-02-01

    Technology development in photonics is rapidly progressing. The concept of a Unified Network will provide re- configurable network access to platform sensors, Vehicle Management Systems, Stores and avionics. The re-configurable taps into the network will accommodate present interface standards and provide scaleability for the insertion of future interfaces. Significant to this development is the design and test of the Optical Backplane Interconnect System funded by Naval Air Systems Command and developed by Lockheed Martin Tactical Defense Systems - Eagan. OBIS results in the merging of the electrical backplane and the optical backplane, with interconnect fabric and card edge connectors finally providing adequate electrical and optical card access. Presently OBIS will support 1.2 Gb/s per fiber over multiples of 12 fibers per ribbon cable.

  17. An experimental study on the shear strength of FRP perfobond shear connector

    NASA Astrophysics Data System (ADS)

    Gwon, S. C.; Kim, S. H.; Yoon, S. J.; Choi, C. W.

    2018-06-01

    In this study, push-out tests were conducted to investigate shear behaviour of FRP perfobond shear connector. The parameters influencing shear capacity of FRP perfobond shear connector are concrete dowel effect, shear resistance effect of the laterally reinforced FRP re- bar, and frictional effect between shear connector and concrete. The specimens were designed to consider these parameters. The specimens coated with sand to increase frictional resistance between the FRP re-bar and concrete. Based on the test results and the parameters, new equation was suggested to predict shear strength of FRP perfobond shear connectors. The predicted results and the experimental results were compared to check the feasibility of prediction.

  18. Connection technology of HPTO type WECs and DC nano grid in island

    NASA Astrophysics Data System (ADS)

    Wang, Kun-lin; Tian, Lian-fang; You, Ya-ge; Wang, Xiao-hong; Sheng, Song-wei; Zhang, Ya-qun; Ye, Yin

    2016-07-01

    Wave energy fluctuating a great deal endangers the security of power grid especially micro grid in island. A DC nano grid supported by batteries is proposed to smooth the output power of wave energy converters (WECs). Thus, renewable energy converters connected to DC grid is a new subject. The characteristics of WECs are very important to the connection technology of HPTO type WECs and DC nano grid. Hydraulic power take-off system (HPTO) is the core unit of the largest category of WECs, with the functions of supplying suitable damping for a WEC to absorb wave energy, and converting captured wave energy to electricity. The HPTO is divided into a hydraulic energy storage system (HESS) and a hydraulic power generation system (HPGS). A primary numerical model for the HPGS is established in this paper. Three important basic characteristics of the HPGS are deduced, which reveal how the generator load determines the HPGS rotation rate. Therefore, the connector of HPTO type WEC and DC nano grid would be an uncontrollable rectifier with high reliability, also would be a controllable power converter with high efficiency, such as interleaved boost converter-IBC. The research shows that it is very flexible to connect to DC nano grid for WECs, but bypass resistance loads are indispensable for the security of WECs.

  19. Stent longitudinal integrity bench insights into a clinical problem.

    PubMed

    Ormiston, John A; Webber, Bruce; Webster, Mark W I

    2011-12-01

    Standardized bench-top compression and elongation testing was undertaken to assess the longitudinal strength of contemporary stents. Insights gained may improve clinical stent choice and deployment techniques, and facilitate future stent design improvements. The hoops of coronary stents provide radial support, and connectors hold hoops together. Strut material, shape, and thickness, along with connector number and configuration, provide the balance between stent flexibility and longitudinal integrity. Longitudinal distortion manifests as length change, strut overlap, strut separation, malapposition, and luminal obstruction. These may predispose to restenosis and stent thrombosis, obstruct passage of devices, be misinterpreted as strut fracture, and require additional stenting. The force required to compress and to elongate 7 contemporary stents was measured with an Instron universal testing machine (Norwood, Massachusetts). Stents deployed in a silicone phantom damaged by a balloon or guide catheter were imaged by microcomputed tomography to understand better the appearances and effects of longitudinal distortion. Stents with 2 connectors (Boston Scientific [Natick, Massachusetts] Omega and Medtronic [Santa Rosa, California] Driver) required significantly less force to be compressed up to 5 mm and elongated by 1 mm than designs with more connectors. The 6-connector Cypher Select required significantly more force to be elongated 5 mm than other designs. Stents with 2 connectors between hoops have less longitudinal strength when exposed to compressing or elongating forces than those with more connectors. This independent, standardized study may assist stent selection in clinical situations where longitudinal integrity is important, and may aid future design improvements. Stent longitudinal strength, the resistance to shortening or elongation, appears related to the number of connectors between hoops. Using a standardized testing protocol, designs with 2 connectors were more likely to shorten or elongate than those with more connectors. Distortion may be recognized clinically as bunching or separation of struts, and may be confused with strut fracture. Without post-dilation or further stent deployment, the patient may be at increased risk for adverse clinical events. A stent design change ensuring 3 connectors, especially at the proximal end of a stent, should increase longitudinal integrity, but perhaps at the expense of stent flexibility. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Nu-Way Snaps and Snap Leads: an Important Connection in the History of Behavior Analysis.

    PubMed

    Escobar, Rogelio; Lattal, Kennon A

    2014-10-01

    Beginning in the early 1950s, the snap lead became an integral and ubiquitous component of the programming of electromechanical modules used in behavioral experiments. It was composed of a Nu-Way snap connector on either end of a colored electrical wire. Snap leads were used to connect the modules to one another, thereby creating the programs that controlled contingencies, arranged reinforcers, and recorded behavior in laboratory experiments. These snap leads populated operant conditioning laboratories from their inception until the turn of the twenty-first century. They allowed quick and flexible programming because of the ease with which they could be connected, stacked, and removed. Thus, the snap lead was integral to the research activity that constituted the experimental analysis of behavior for more than five decades. This review traces the history of the snap lead from the origins of the snap connector in Birmingham, England, in the late eighteenth century, through the use of snaps connected to wires during the Second World War, to its adoption in operant laboratories, and finally to its demise in the digital age.

  1. Rail assembly for use in a radioactive environment

    DOEpatents

    Watts, Ralph E.

    1989-01-01

    An improved rail assembly and method of construction thereof is disclosed herein that is particularly adapted for use with a crane trolley in a hot cell environment which is exposed to airborne and liquidborne radioactive contaminants. The rail assembly is generally comprised of a support wall having an elongated, rail-housing recess having a floor, side wall and ceiling. The floor of the recess is defined at least in part by the load-bearing surface of a rail, and is substantially flat, level and crevice-free to facilitate the drainage of liquids out of the recess. The ceiling of the recess overhangs and thereby captures trolley wheels within the recess to prevent them from becoming dislodged from the recess during a seismic disturbance. Finally, the interior of the recess includes a power track having a slot for receiving a sliding electrical connector from the crane trolley. The power track is mounted in an upper corner of the recess with its connector-receiving groove oriented downwardly to facilitate the drainage of liquidborne contaminants and to discourage the collection of airborne contaminants within the track.

  2. Ultra high performance connectors for power transmission applications

    DOEpatents

    Wang, Jy-An; Ren, Fei; Lee, Dominic F; Jiang, Hao

    2014-03-04

    Disclosed are several examples of an apparatus for connecting the free ends of two electrical power transmission lines having conductor strands disposed around a central, reinforcing core. The examples include an inner sleeve having a body defining an inner bore passing through an axially-extending, central axis, an outer rim surface disposed radially outward from the central bore, and one or more axially-extending grooves penetrating the body at the outer rim surface. Also included is an outer splice having a tubular shaped body with a bore passing coaxially through the central axis, the bore defining an inner rim surface for accepting the inner sleeve. The inner bore of the inner sleeve accepts the reinforcement cores of the two conductors, and the grooves accept the conductor strands in an overlapping configuration so that a majority of the electrical current flows between the overlapped conductor strands when the conductors are transmitting electrical current.

  3. Logical Connectors, Grounding and Cognition.

    ERIC Educational Resources Information Center

    Chen, Rong

    1991-01-01

    Study of a group of logical connectors in English demonstrates how the meanings of those connectors signal the grounding of the clauses they introduce in absolute terms, unlike other linguistic means of grounding performed by tense, aspect, mood, voice, or verbal categories. (14 references) (Author/CB)

  4. Dynamic Assembly, Assessment, Assurance, and Adaptation via Heterogeneous Software Connectors

    DTIC Science & Technology

    2004-10-01

    Versioning Connectors (MVC) Representative of runtime monitoring gauges are multiversioning gauges, which monitor and analyze different versions of...multiple versions of the same component must be merged by the connector before they are forwarded to their target components. The multiversioning

  5. X-connectors for tubing - Feasibility study

    NASA Technical Reports Server (NTRS)

    Bragg, K.; Fuhrmann, H. W.

    1970-01-01

    Connector tests, including 70 deg F leakage and vibration, proof pressure, burst pressure, tensility, thermal shock, high and low temperature leakage, and simultaneous high temperature vibration and leakage, prove feasibility of lightweight 0.5-in. X-connectors for 4500-lb/sq in. service pressures.

  6. Piping Connector

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A complex of high pressure piping at Stennis Space Center carries rocket propellants and other fluids/gases through the Center's Component Test Facility. Conventional clamped connectors tend to leak when propellant lines are chilled to extremely low temperatures. Reflange, Inc. customized an existing piping connector to include a secondary seal more tolerant of severe thermal gradients for Stennis. The T-Con connector solved the problem, and the company is now marketing a commercial version that permits testing, monitoring or collecting any emissions that may escape the primary seal during severe thermal transition.

  7. Terminating Devices in Spoken French.

    ERIC Educational Resources Information Center

    Andrews, Barry J.

    1989-01-01

    A study examines the way in which one group of discourse connectors, terminators, function in contemporary spoken French. Three types of terminators, elements used at the end of an utterance or section to indicate its completion, are investigated, including utterance terminators, interrogative tags, and terminal tags. (Author/MSE)

  8. Towards data integration automation for the French rare disease registry.

    PubMed

    Maaroufi, Meriem; Choquet, Rémy; Landais, Paul; Jaulent, Marie-Christine

    2015-01-01

    Building a medical registry upon an existing infrastructure and rooted practices is not an easy task. It is the case for the BNDMR project, the French rare disease registry, that aims to collect administrative and medical data of rare disease patients seen in different hospitals. To avoid duplicating data entry for health professionals, the project plans to deploy connectors with the existing systems to automatically retrieve data. Given the data heterogeneity and the large number of source systems, the automation of connectors creation is required. In this context, we propose a methodology that optimizes the use of existing alignment approaches in the data integration processes. The generated mappings are formalized in exploitable mapping expressions. Following this methodology, a process has been experimented on specific data types of a source system: Boolean and predefined lists. As a result, effectiveness of the used alignment approach has been enhanced and more good mappings have been detected. Nonetheless, further improvements could be done to deal with the semantic issue and process other data types.

  9. Towards data integration automation for the French rare disease registry

    PubMed Central

    Maaroufi, Meriem; Choquet, Rémy; Landais, Paul; Jaulent, Marie-Christine

    2015-01-01

    Building a medical registry upon an existing infrastructure and rooted practices is not an easy task. It is the case for the BNDMR project, the French rare disease registry, that aims to collect administrative and medical data of rare disease patients seen in different hospitals. To avoid duplicating data entry for health professionals, the project plans to deploy connectors with the existing systems to automatically retrieve data. Given the data heterogeneity and the large number of source systems, the automation of connectors creation is required. In this context, we propose a methodology that optimizes the use of existing alignment approaches in the data integration processes. The generated mappings are formalized in exploitable mapping expressions. Following this methodology, a process has been experimented on specific data types of a source system: Boolean and predefined lists. As a result, effectiveness of the used alignment approach has been enhanced and more good mappings have been detected. Nonetheless, further improvements could be done to deal with the semantic issue and process other data types. PMID:26958224

  10. Correction for Thermal EMFs in Thermocouple Feedthroughs

    NASA Technical Reports Server (NTRS)

    Ziemke, Robert A.

    2006-01-01

    A straightforward measurement technique provides for correction of thermal-electromotive-force (thermal-EMF) errors introduced by temperature gradients along the pins of non-thermocouple-alloy hermetic feedthrough connectors for thermocouple extension wires that must pass through bulkheads. This technique is an alternative to the traditional technique in which the thermal-EMF errors are eliminated by use of custom-made multipin hermetic feedthrough connectors that contain pins made of the same alloys as those of the thermocouple extension wires. One disadvantage of the traditional technique is that it is expensive and time-consuming to fabricate multipin custom thermocouple connectors. In addition, the thermocouple-alloy pins in these connectors tend to corrode easily and/or tend to be less rugged compared to the non-thermocouple-alloy pins of ordinary connectors. As the number of thermocouples (and thus pins) is increased in a given setup, the magnitude of these disadvantages increases accordingly. The present technique is implemented by means of a little additional hardware and software, the cost of which is more than offset by the savings incurred through the use of ordinary instead of thermocouple connectors. The figure schematically depicts a typical measurement setup to which the technique is applied. The additional hardware includes an isothermal block (made of copper) instrumented with a reference thermocouple and a compensation thermocouple. The reference thermocouple is connected to an external data-acquisition system (DAS) through a two-pin thermocouple-alloy hermetic feedthrough connector, but this is the only such connector in the apparatus. The compensation thermocouple is connected to the DAS through two pins of the same ordinary multipin connector that connects the measurement thermocouples to the DAS.

  11. KSC-08pd0043

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Lloyd Johns, with Lockheed Martin, attaches the replacement feed-through connector in the engine cutoff, or ECO, sensor system to the internal connector on space shuttle Atlantis' external tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  12. KSC-08pd0044

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Lloyd Johns, with Lockheed Martin, attaches the replacement feed-through connector in the engine cutoff, or ECO, sensor system to the internal connector on space shuttle Atlantis' external tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  13. Low-profile fiber connector for co-packaged optics

    NASA Astrophysics Data System (ADS)

    Brusberg, Lars; DeJong, Michael; Butler, Douglas L.; Clark, Jeffrey S.; Sutton, Clifford G.

    2018-02-01

    We developed a small form factor connector that can be assembled on all four sides of a high-data switch package for fiber connectivity. This paper discusses a novel connector approach that has the potential to meet all co-packaging requirements including solder-reflow-compatibility, de-mateability, low insertion loss and state-of-the art FAU attach. The connector was attached to the PIC for performance evaluation. The average insertion loss across all eight fibers of the assembly was 1.77 dB, including the three optical interfaces: (1) MT-to-MT between connector and receptacle, (2) receptacle-to-PLC and (3) PIC-to-FAU. Also included is the propagation loss of the PIC waveguide. Optical return loss was measured to be -55 dB or lower.

  14. Microfluidic interconnects

    DOEpatents

    Benett, William J.; Krulevitch, Peter A.

    2001-01-01

    A miniature connector for introducing microliter quantities of solutions into microfabricated fluidic devices, and which incorporates a molded ring or seal set into a ferrule cartridge, with or without a compression screw. The fluidic connector, for example, joins standard high pressure liquid chromatography (HPLC) tubing to 1 mm diameter holes in silicon or glass, enabling ml-sized volumes of sample solutions to be merged with .mu.l-sized devices. The connector has many features, including ease of connect and disconnect; a small footprint which enables numerous connectors to be located in a small area; low dead volume; helium leak-tight; and tubing does not twist during connection. Thus the connector enables easy and effective change of microfluidic devices and introduction of different solutions in the devices.

  15. Tool enables proper mating of accelerometer and cable connector

    NASA Technical Reports Server (NTRS)

    Steed, C. N.

    1966-01-01

    Tool supports accelerometer in axial alignment with an accelerometer cable connector and permits tightening of the accelerometer to the cable connector with a torque wrench. This is done without damaging the components or permitting them to work loose under sustained, high-level vibrations.

  16. Using Three-Dimensional Printing to Fabricate a Tubing Connector for Dilation and Evacuation.

    PubMed

    Stitely, Michael L; Paterson, Helen

    2016-02-01

    This is a proof-of-concept study to show that simple instrumentation problems encountered in surgery can be solved by fabricating devices using a three-dimensional printer. The device used in the study is a simple tubing connector fashioned to connect two segments of suction tubing used in a surgical procedure where no commercially available product for this use is available through our usual suppliers in New Zealand. A cylindrical tubing connector was designed using three-dimensional printing design software. The tubing connector was fabricated using the Makerbot Replicator 2X three-dimensional printer. The connector was used in 15 second-trimester dilation and evacuation procedures. Data forms were completed by the primary operating surgeon. Descriptive statistics were used with the expectation that the device would function as intended in all cases. The three-dimensional printed tubing connector functioned as intended in all 15 instances. Commercially available three-dimensional printing technology can be used to overcome simple instrumentation problems encountered during gynecologic surgical procedures.

  17. Randomized clinical trial of implant-supported ceramic-ceramic and metal-ceramic fixed dental prostheses: preliminary results.

    PubMed

    Esquivel-Upshaw, Josephine F; Clark, Arthur E; Shuster, Jonathan J; Anusavice, Kenneth J

    2014-02-01

    The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52-75 years) were recruited for the study to receive a three-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD, and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher's exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0.91). Although there were no significant associations between connector height, curvature of gingival embrasure, core/veneer thickness ratio, and material system and the survival probability of implant-supported FDPs with zirconia as a core material, the small number of fractures precludes a definitive conclusion on the dominant controlling factor. © 2013 by the American College of Prosthodontists.

  18. Randomized Clinical Trial of Implant-Supported Ceramic-Ceramic and Metal-Ceramic Fixed Dental Prostheses: Preliminary Results

    PubMed Central

    Esquivel-Upshaw, Josephine F.; Clark, Arthur E.; Shuster, Jonathan J.; Anusavice, Kenneth J.

    2013-01-01

    Purpose The aim of this study was to determine the survival rates over time of implant-supported ceramic-ceramic and metal-ceramic prostheses as a function of core-veneer thickness ratio, gingival connector embrasure design, and connector height. Materials and Methods An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study involving 55 patients missing three teeth in either one or two posterior areas. These patients (34 women; 21 men; age range 52–75 years) were recruited for the study to receive a 3-unit implant-supported fixed dental prosthesis (FDP). Two implants were placed for each of the 72 FDPs in the study. The implants (Osseospeed, Astra Tech), which were made of titanium, were grit blasted. A gold-shaded, custom-milled titanium abutment (Atlantis, Astra Tech), was secured to each implant body. Each of the 72 FDPs in 55 patients were randomly assigned based on one of the following options: (1) A. Material: ceramic-ceramic (Yttria-stabilized zirconia core, pressable fluorapatite glass-ceramic, IPS e.max ZirCAD and ZirPress, Ivoclar Vivadent) B. metal-ceramic (palladium-based noble alloy, Capricorn, Ivoclar Vivadent, with press-on leucite-reinforced glass-ceramic veneer, IPS InLine POM, Ivoclar Vivadent); (2) occlusal veneer thickness (0.5, 1.0, and 1.5 mm); (3) curvature of gingival embrasure (0.25, 0.5, and 0.75 mm diameter); and (4) connector height (3, 4, and 5 mm). FDPs were fabricated and cemented with dual-cure resin cement (RelyX, Universal Cement, 3M ESPE). Patients were recalled at 6 months, 1 year, and 2 years. FDPs were examined for cracks, fracture, and general surface quality. Results Recall exams of 72 prostheses revealed 10 chipping fractures. No fractures occurred within the connector or embrasure areas. Two-sided Fisher’s exact tests showed no significant correlation between fractures and type of material system (p = 0.51), veneer thickness (p = 0.75), radius of curvature of gingival embrasure (p = 0.68), and connector height (p = 0.91). Conclusions Although there were no significant associations between connector height, curvature of gingival embrasure, core/veneer thickness ratio, and material system and the survival probability of implant-supported FDPs with zirconia as a core material, the small number of fractures precludes a definitive conclusion on the dominant controlling factor. PMID:23758092

  19. Floating device aligns blind connections

    NASA Technical Reports Server (NTRS)

    Resel, J. E.

    1966-01-01

    Panel-mounted connectors overcome the misalignment of blind connectors in electronic rack mounted equipment. The connector is free to move in the vertical direction by the action of a parallelogram mount. This freedom of motion maintains the guide pin hole centerline parallel to the guide pin centerline at all times.

  20. 76 FR 69328 - Proposed Collection; Comment Request; Race and National Origin Identification

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ... DEPARTMENT OF THE TREASURY Proposed Collection; Comment Request; Race and National Origin... INFORMATION: OMB Number: 1505-0195. Type of Review: Revision of a currently approved collection. Title: Race...Connector, is used to capture race and national origin information electronically from an applicant. The...

  1. Plug-in connector socket accepts coaxial cable end

    NASA Technical Reports Server (NTRS)

    Mitchell, D.; Van Loon, J.

    1966-01-01

    Connector which includes a spring-loaded contact to receive a protruding center conductor and an internal collet to clamp against a collar attached to a woven outer conductor, is used as a receptacle for the end of a coaxial cable. This plug-in connector socket is used successfully with remote manipulators.

  2. 77 FR 35306 - Airworthiness Directives; Bell Helicopter Textron, Inc. Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ... assemblies (power cable assemblies). This proposed AD is prompted by the determination that the power cable assembly connector (connector) can deteriorate, causing a short in the connector that may lead to a fire. This AD would require replacing the power cable assemblies and their associated parts, and performing...

  3. 40 CFR 65.110 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and..., valves, connectors, and agitators in heavy liquid service; pressure relief devices in light liquid or...

  4. 40 CFR 65.110 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and..., valves, connectors, and agitators in heavy liquid service; pressure relief devices in light liquid or...

  5. 40 CFR 65.110 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and..., valves, connectors, and agitators in heavy liquid service; pressure relief devices in light liquid or...

  6. 40 CFR 65.110 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., and agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and..., valves, connectors, and agitators in heavy liquid service; pressure relief devices in light liquid or...

  7. 40 CFR 65.110 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; pressure relief...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and agitators in heavy liquid service; pressure relief devices in liquid service; and instrumentation..., connectors, and agitators in heavy liquid service; pressure relief devices in liquid service; and..., valves, connectors, and agitators in heavy liquid service; pressure relief devices in light liquid or...

  8. 40 CFR 63.169 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; instrumentation...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., and agitators in heavy liquid service; instrumentation systems; and pressure relief devices in liquid...: Pumps, valves, connectors, and agitators in heavy liquid service; instrumentation systems; and pressure relief devices in liquid service. (a) Pumps, valves, connectors, and agitators in heavy liquid service...

  9. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  10. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  11. 29 CFR 1926.754 - Structural steel assembly.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... connectors on composite floors, roofs and bridge decks. When shear connectors are used in construction of composite floors, roofs and bridge decks, employees shall lay out and install the shear connectors after the... requirements of paragraph (e)(3)(i) of this section. (4) Decking gaps around columns. Wire mesh, exterior...

  12. Electronics box having internal circuit cards interconnected to external connectors sans motherboard

    NASA Technical Reports Server (NTRS)

    Hockett, John E. (Inventor)

    2005-01-01

    An electronics chassis box includes a pair of opposing sidewalls, a pair of opposing end walls, a bottom surface, a top cover, and ring connectors assemblies mounted in selective ones of the walls of the electronic box. Boss members extend from the bottom surface at different heights upon which circuit cards are mounted in spatial relationship to each other. A flex interconnect substantially reduces and generally eliminates the need of a motherboard by interconnecting the circuit cards to one another and to external connectors mounted within the ring connector assemblies.

  13. Three-Dimensional Waveguide Arrays for Coupling Between Fiber-Optic Connectors and Surface-Mounted Optoelectronic Devices

    NASA Astrophysics Data System (ADS)

    Hiramatsu, Seiki; Kinoshita, Masao

    2005-09-01

    This paper describes the fabrication of novel surface-mountable waveguide connectors and presents test results for them. To ensure more highly integrated and low-cost fabrication, we propose new three-dimensional (3-D) waveguide arrays that feature two-dimensionally integrated optical inputs/outputs and optical path redirection. A wafer-level stack and lamination process was used to fabricate the waveguide arrays. Vertical-cavity surface-emitting lasers (VCSELs) and photodiodes were directly mounted on the arrays and combined with mechanical transferable ferrule using active alignment. With the help of a flip-chip bonder, the waveguide connectors were mounted on a printed circuit board by solder bumps. Using mechanical transferable connectors, which can easily plug into the waveguide connectors, we obtained multi-gigabits-per-second transmission performance.

  14. KSC-08pd0038

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- This closeup shows the internal connector to which the replacement feed-through connector in the engine cutoff, or ECO, sensor system on space shuttle Atlantis' external tank will be installed. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  15. KSC-08pd0045

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Ray Clark, a Lockheed Martin engineer, completes attaching the replacement feed-through connector in the engine cutoff, or ECO, sensor system to the internal connector on space shuttle Atlantis' external tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  16. KSC-08pd0042

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Jim Davis, a NASA quality inspector, examines the internal connector on space shuttle Atlantis' external tank to which the replacement feed-through connector in the engine cutoff, or ECO, sensor system will be attached. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  17. Small form factor optical fiber connector evaluation for harsh environments

    NASA Astrophysics Data System (ADS)

    Ott, Melanie N.; Thomes, W. Joe, Jr.; Chuska, Richard F.; Switzer, Robert; Blair, Diana E.

    2011-09-01

    For the past decade NASA programs have utilized the Diamond AVIM connector for optical fiber assemblies on space flight instrumentation. These connectors have been used in communications, sensing and LIDAR systems where repeatability and high performance are required. Recently Diamond has released a smaller form factor optical fiber connector called the "Mini-AVIM" which although more compact still includes the tight tolerances and the ratcheting feature of the heritage AVIM. NASA Goddard Space Flight Center Photonics Group in the Parts, Packaging and Assembly Technologies Office has been performing evaluations of this connector to determine how it compares to the performance of the AVIM connector and to assess its feasibility for harsh environmental applications. Vibration and thermal testing were performed on the Mini-AVIM with both multi-mode and single-mode optical fiber using insitu optical transmission monitoring. Random vibration testing was performed using typical launch condition profiles for most NASA missions but extended to 35 Grms, which is much higher than most requirements. Thermal testing was performed incrementally up to a range of -55°C to +125°C. The test results include both unjacketed fiber and cabled assembly evaluations. The data presented here indicate that the Mini-AVIM provides a viable option for small form factor applications that require a high performance optical fiber connector.

  18. The Development of a High-Power, Low-Frequency Underwater Acoustic Source for Use in a Deep-Towed Geophysical Array Section

    DTIC Science & Technology

    1982-11-15

    Metca) for each ring 6 Aluminum orirlce end ring 15 Rubber bumpers 7 Back plate inner boot ring 16 Castor oil rill-fluid I ’)-ring %eals I ’ Nikel ...electrode .ab% with hook-up wire -ig. 6 - Sectional v-icw orf ISRI) typc (662 tran.dhcer 9 YOUNG, TIMS. AND HENRIQUFZ 0.42 m. Approximately 85% of the...electrical leads for each ring are routed to individual bulkhead connectors on the trans- ducer back plate with high-voltage silicone-jacketed hookup wire

  19. Flat conductor cable design, manufacture, and installation

    NASA Technical Reports Server (NTRS)

    Angele, W.; Hankins, J. D.

    1973-01-01

    Pertinent information for hardware selection, design, manufacture, and quality control necessary for flat conductor cable interconnecting harness application is presented. Comparisons are made between round wire cable and flat conductor cable. The flat conductor cable interconnecting harness systems show major cost, weight, and space savings, plus increased system performance and reliability. The design application section includes electrical characteristics, harness design and development, and a full treatise on EMC considerations. Manufacturing and quality control sections pertain primarily to the developed conductor-contact connector system and special flat conductor cable to round wire cable transitions.

  20. Preventing central venous catheter-associated bloodstream infections: development of an antiseptic barrier cap for needleless connectors.

    PubMed

    Menyhay, Steve Z; Maki, Dennis G

    2008-12-01

    Reports of outbreaks associated with the use of needle-free valve connectors suggest 2 common risk factors: (1) poor adherence to disinfection practices before use and (2) a design that allows contamination when not in use. Swabbing a membranous septum with 70% isopropyl alcohol may not eliminate septal surface contamination. Frequent access through and handling of needle-free connectors also puts patients at increased risk of central venous catheter-related bloodstream infections (CR-BSIs). A novel antiseptic barrier cap has been designed to maintain health care worker safety and eliminate the vulnerabilities of existing systems to contamination and CR-BSIs for patients at risk. A prospective in vitro study compared the effectiveness of standard disinfection of needleless luer-activated valve connectors with 70% isopropyl alcohol and the effectiveness of an antiseptic barrier cap that, when threaded onto a luer-activated connector, rapidly sterilizes a heavily contaminated surface. Standard disinfection was done by 3- to 5-second swabbing using a sterile commercial pledget of 70% isopropyl alcohol. The antiseptic barrier cap comprises an outer cap with internal female threads and a spike inside the closed end, a capsule containing 0.25 mL of 2% chlorhexidine gluconate in 70% isopropyl alcohol, and a sponge between the septum and the capsule. When the cap is threaded onto a luer-adaptable needleless connector, the spike ruptures the capsule, saturating the sponge with the antiseptic. All 15 (100%) of the precontaminated positive control connectors not disinfected before entry showed transmission of Enterococcus faecalis across the membranous septum (4500-28,000 colony-forming units), and 20 (67%) of 30 connectors disinfected with 70% alcohol showed transmission (442-25,000 colony-forming units). Of 60 needle-free connectors disinfected with the antiseptic barrier cap, 1 (1.6%) showed transmission (P < .001). An antiseptic barrier cap was highly effective in sterilizing the septum of a needle-free valve connector and preventing entry of any microorganisms, even with heavy contamination of the septum. This new technology should now be evaluated in a clinical trial with CR-BSI as the primary outcome measure.

  1. Tool for Coupling a Torque Wrench to a Round Cable Connector

    NASA Technical Reports Server (NTRS)

    Hacker, Scott C.; Dean, Richard J.; Burge, Scott W.

    2006-01-01

    A tool makes it possible to couple a torque wrench to an externally knurled, internally threaded, round cable connector. The purpose served by the tool is to facilitate the tightening of multiple such connectors (or the repeated tightening of the same connector) to repeatable torques. The design of a prior cable-connector/ torque-wrench coupling tool provided for application of the torque-wrench jaws to a location laterally offset from the axis of rotation of the cable connector, making it necessary to correct the torque reading for the offset. Unlike the design of the prior tool, the design of the present tool provides for application of the torque-wrench jaws to a location on the axis of rotation, obviating correction of the torque reading for offset. The present tool (see figure) consists of a split collet containing a slot that provides clearance for inserting and bending the cable, a collet-locking sleeve, a collet-locking nut, and a torque-wrench adaptor that is press-fit onto the collet. Once the collet is positioned on the cable connector, the collet-locking nut is turned to force the collet-locking sleeve over the collet, compressing the collet through engagement of tapered surfaces on the outside of the collet and the inside of the locking sleeve. Because the collet is split and therefore somewhat flexible, this compression forces the collet inward to grip the connector securely. The torque wrench is then applied to the torque-wrench adaptor in the usual manner for torquing a nut or a bolt.

  2. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agamy, Mohammed

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiringmore » and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.« less

  3. Material morphology and electrical resistivity differences in EPDM rubbers.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Nancy Y. C.; Domeier, Linda A.

    2008-03-01

    Electrical resistance anomalies noted in EPDM gaskets have been attributed to zinc-enriched surface sublayers, about 10-{micro}m thick, in the sulfur cured rubber material. Gasket over-compression provided the necessary connector pin contact and was also found to cause surprising morphological changes on the gasket surfaces. These included distributions of zinc oxide whiskers in high pressure gasket areas and cone-shaped features rich in zinc, oxygen, and sulfur primarily in low pressure protruding gasket areas. Such whiskers and cones were only found on the pin side of the gaskets in contact with a molded plastic surface and not on the back side inmore » contact with an aluminum surface. The mechanisms by which such features are formed have not yet been defined.« less

  4. 30 CFR 7.69 - Approval marking.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that the unit's components must not be disassembled or removed. (d) The replacement battery types if the unit has replaceable batteries. (e) A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used. (f) A warning that the...

  5. 30 CFR 7.69 - Approval marking.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... that the unit's components must not be disassembled or removed. (d) The replacement battery types if the unit has replaceable batteries. (e) A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used. (f) A warning that the...

  6. 30 CFR 7.69 - Approval marking.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that the unit's components must not be disassembled or removed. (d) The replacement battery types if the unit has replaceable batteries. (e) A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used. (f) A warning that the...

  7. 30 CFR 7.69 - Approval marking.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... that the unit's components must not be disassembled or removed. (d) The replacement battery types if the unit has replaceable batteries. (e) A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used. (f) A warning that the...

  8. 30 CFR 7.69 - Approval marking.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that the unit's components must not be disassembled or removed. (d) The replacement battery types if the unit has replaceable batteries. (e) A warning placed next to the charging connector that the battery only be charged in a fresh air location if rechargeable batteries are used. (f) A warning that the...

  9. Connector interchangeability

    NASA Technical Reports Server (NTRS)

    Berilla, T.

    1972-01-01

    The application is discussed of the general rules of ANSI Y14.5 in designing connectors for interchangeability, and lowering costs. The general rules are applied to actural connector designs, and existing specifications are identified that (1) reject better quality products than those accepted, (2) accept products which should be rejected, and (3) impose unnecessary, nonfunctional costly requirements.

  10. 77 FR 8898 - Certain Coaxial Cable Connectors and Components Thereof and Products Containing Same; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-15

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-650] Certain Coaxial Cable Connectors and... States after importation of certain coaxial cable connectors and components thereof and products... an advisory opinion under Commission Rule 210.79 (19 CFR 210.79) that would declare that its coaxial...

  11. A proposed adjustable RF cable connector

    NASA Technical Reports Server (NTRS)

    Stringer, E. J.; Doyle, J. D.

    1973-01-01

    In system that requires negligible loss, it may be necessary to adjust cable length to exact multiple of transmitted wavelength. Adjustable cable connector saves time and cost by eliminating need to add to or cut from cable. Device was especially designed for use with high frequencies. For particular application, connector of suitable dimensions should be used.

  12. 76 FR 68297 - Airworthiness Directives; Agusta S.p.A. (Agusta) Model AB139 and AW139 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-04

    ... card assemblies. Analysis of the in-flight emergencies identified salt water and extreme moisture as... and related connectors for corrosion. If there is corrosion on the connectors, this AD requires cleaning the connectors before further flight. If there is corrosion on a module, before further flight...

  13. 40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...

  14. 40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...

  15. 40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...

  16. 40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...

  17. 40 CFR 65.108 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Standards: Connectors in gas/vapor service and in light liquid service. (a) Compliance schedule. Except as... 40 Protection of Environment 16 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 65.108 Section 65.108 Protection of Environment ENVIRONMENTAL...

  18. KSC-08pd0076

    NASA Image and Video Library

    2008-01-23

    KENNEDY SPACE CENTER, FLA. -- The white foam insulation freshly reapplied to space shuttle Atlantis's external tank completes the work to remove and replace the feed-through connector on the engine cut-off, or ECO, sensor connector. The repair work was done on Atlantis while the shuttle has been on Launch Pad 39A at NASA's Kennedy Space Center. The foam was removed to enable engineers to remove and replace the ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The repair work was done on Atlantis while the shuttle has been on Launch Pad 39A at NASA's Kennedy Space Center. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Cory Husten

  19. KSC-08pd0075

    NASA Image and Video Library

    2008-01-23

    KENNEDY SPACE CENTER, FLA. -- The white foam insulation freshly reapplied to space shuttle Atlantis's external tank completes the work to remove and replace the feed-through connector on the engine cut-off, or ECO, sensor connector. The repair work was done on Atlantis while the shuttle has been on Launch Pad 39A at NASA's Kennedy Space Center. The foam was removed to enable engineers to remove and replace the ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The repair work was done on Atlantis while the shuttle has been on Launch Pad 39A at NASA's Kennedy Space Center. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Cory Husten

  20. Visual Sensor for Sterilization of Polymer Fixtures Using Embedded Mesoporous Silicon Photonic Crystals.

    PubMed

    Kumeria, Tushar; Wang, Joanna; Chan, Nicole; Harris, Todd J; Sailor, Michael J

    2018-01-26

    A porous photonic crystal is integrated with a plastic medical fixture (IV connector hub) to provide a visual colorimetric sensor to indicate the presence or absence of alcohol used to sterilize the fixture. The photonic crystal is prepared in porous silicon (pSi) by electrochemical anodization of single crystal silicon, and the porosity and the stop band of the material is engineered such that the integrated device visibly changes color (green to red or blue to green) when infiltrated with alcohol. Two types of self-reporting devices are prepared and their performance compared: the first type involves heat-assisted fusion of a freestanding pSi photonic crystal to the connector end of a preformed polycarbonate hub, forming a composite where the unfilled portion of the pSi film acts as the sensor; the second involves generation of an all-polymer replica of the pSi photonic crystal by complete thermal infiltration of the pSi film and subsequent chemical dissolution of the pSi portion. Both types of sensors visibly change color when wetted with alcohol, and the color reverts to the original upon evaporation of the liquid. The sensor performance is verified using E. coli-infected samples.

  1. On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy.

    PubMed

    Chen, Z; Agostinelli, A; Nath, R

    1998-03-01

    The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120 cm x 200 cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated than an additional error of up to 4% could be introduced if the unshielded cable's spatial configuration were altered during the two-polarity measurements. This suggests that automatic scanning systems with unshielded cables should not be used in TSET ionization chamber dosimetry. However, the data did show that an unshielded cable may be used in TSET ionization chamber dosimetry if the size of cable-induced error in a given TSET beam is pre-evaluated and the measurement is carefully conducted. When such an evaluation has not been performed, additional shielding should be applied to the cable being used, making measurements at multiple points difficult.

  2. Intermediate connector for stacked organic light emitting devices

    DOEpatents

    D& #x27; Andrade, Brian

    2013-02-12

    A device is provided, having an anode, a cathode, and an intermediate connector disposed between the anode and the cathode. A first organic layer including an emissive sublayer is disposed between the anode and the intermediate connector, and a second including an emissive sublayer is disposed between the intermediate connector and the cathode. The intermediate connector includes a first metal having a work function lower than 4.0 eV and a second metal having a work function lower than 5.0 eV. The work function of the first metal is at least 0.5 eV less than the work function of the second metal. The first metal is in contact with a sublayer of the second organic layer that includes a material well adapted to receive holes from a low work function metal.

  3. KSC-08pd0066

    NASA Image and Video Library

    2008-01-17

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam is being replaced around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  4. KSC-08pd0067

    NASA Image and Video Library

    2008-01-17

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam is being replaced around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  5. tranSMART-XNAT Connector tranSMART-XNAT connector-image selection based on clinical phenotypes and genetic profiles.

    PubMed

    He, Sijin; Yong, May; Matthews, Paul M; Guo, Yike

    2017-03-01

    TranSMART has a wide range of functionalities for translational research and a large user community, but it does not support imaging data. In this context, imaging data typically includes 2D or 3D sets of magnitude data and metadata information. Imaging data may summarise complex feature descriptions in a less biased fashion than user defined plain texts and numeric numbers. Imaging data also is contextualised by other data sets and may be analysed jointly with other data that can explain features or their variation. Here we describe the tranSMART-XNAT Connector we have developed. This connector consists of components for data capture, organisation and analysis. Data capture is responsible for imaging capture either from PACS system or directly from an MRI scanner, or from raw data files. Data are organised in a similar fashion as tranSMART and are stored in a format that allows direct analysis within tranSMART. The connector enables selection and download of DICOM images and associated resources using subjects' clinical phenotypic and genotypic criteria. tranSMART-XNAT connector is written in Java/Groovy/Grails. It is maintained and available for download at https://github.com/sh107/transmart-xnat-connector.git. sijin@ebi.ac.uk. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  6. Calibration of optimal use parameters for an ultraviolet light-emitting diode in eliminating bacterial contamination on needleless connectors.

    PubMed

    Hutchens, M P; Drennan, S L; Cambronne, E D

    2015-06-01

    Needleless connectors may develop bacterial contamination and cause central-line-associated bloodstream infections (CLABSI) despite rigorous application of best-practice. Ultraviolet (UV) light-emitting diodes (LED) are an emerging, increasingly affordable disinfection technology. We tested the hypothesis that a low-power UV LED could reliably eliminate bacteria on needleless central-line ports in a laboratory model of central-line contamination. Needleless central-line connectors were inoculated with Staphylococcus aureus. A 285 nm UV LED was used in calibrated fashion to expose contaminated connectors. Ports were directly applied to agar plates and flushed with sterile saline, allowing assessment of bacterial survival on the port surface and in simulated usage flow-through fluid. UV applied to needleless central-line connectors was highly lethal at 0·5 cm distance at all tested exposure times. At distances >1·5 cm both simulated flow-through and port surface cultures demonstrated significant bacterial growth following UV exposure. Logarithmic-phase S. aureus subcultures were highly susceptible to UV induction/maintenance dosing. Low-power UV LED doses at fixed time and distance from needleless central-line connector ports reduced cultivable S. aureus from >10(6) CFU to below detectable levels in this laboratory simulation of central-line port contamination. Low-power UV LEDs may represent a feasible alternative to current best-practice in connector decontamination. © 2015 The Society for Applied Microbiology.

  7. Preliminary evaluation of hermetic JT/LJT/R P connector socket contact design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baca, J.R.F.

    1991-10-01

    This report presents a precursory examination of a number of issues pertaining to socket contacts in hermetic connectors. The principal issues addressed are high-contact resistance and contact chatter (circuit discontinuities). Efforts examining the characteristics of the existing socket contact design, the possibility of connector/contact rework, quick-fix solutions, and contact redesigns are summarized.

  8. 40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...

  9. 40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...

  10. 40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...

  11. 40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...

  12. 40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...

  13. 40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...

  14. 40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...

  15. 40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...

  16. 40 CFR 63.174 - Standards: Connectors in gas/vapor service and in light liquid service.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Equipment Leaks § 63.174 Standards: Connectors in gas/vapor service and in light liquid service. (a) The... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards: Connectors in gas/vapor service and in light liquid service. 63.174 Section 63.174 Protection of Environment ENVIRONMENTAL...

  17. 40 CFR 63.1008 - Connectors in gas and vapor service and in light liquid service standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 63.1008 Connectors in gas and vapor service and in light liquid service standards. (a) Compliance... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Connectors in gas and vapor service and in light liquid service standards. 63.1008 Section 63.1008 Protection of Environment ENVIRONMENTAL...

  18. Effect of polishing conditions on terminating optical connectors with spherical convex polished ends

    NASA Astrophysics Data System (ADS)

    Lin, Samuel I.-En

    2002-01-01

    Increased demand for fiber-optic technology has created significant growth in the sales of interconnection devices such as fiber-optic connectors, cable assemblies, and adapters. To ensure good connector performance during actual use, several process parameters related to geometric and optical characteristics of the connector must be thoroughly understood during the manufacturing stage. The experimental design has been used here to see the influence of applied pressure and time on the fiber end geometry as well as optical performance. The mathematical model is also applied to explain the phenomena of the present fiber undercut-reflectance relation. By a proper choice of polishing film grit size and processing conditions, it is possible to obtain fiber connectors with less fiber undercut and better return loss. Influences of film grit size and rubber-pad thickness on the reflectance and the fiber undercut are also presented.

  19. KSC-07pd3657

    NASA Image and Video Library

    2007-12-29

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician cuts the external connector cable. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  20. KSC-07pd3666

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, technicians wrap the connector for transport to NASA's Marshall Space Flight Center in Huntsville, Ala., for further cryogenic testing. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  1. KSC-07pd3665

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, technicians wrap the connector for transport to NASA's Marshall Space Flight Center in Huntsville, Ala., for further cryogenic testing. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  2. KSC-07pd3661

    NASA Image and Video Library

    2007-12-29

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, technicians set up equipment that will be used to take X-rays of the connector cable. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  3. KSC-07pd3664

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician inspects the connector just removed from the external tank. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  4. KSC-07pd3663

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician demates the connector from the external tank. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  5. KSC-07pd3662

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician disconnects the connector before it is demated from the external tank. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  6. Expanded beam non-imaging fiber optic connector

    DOEpatents

    Jannson, Tommasz; Jannson, Joanna; Yeung, Peter

    1990-01-01

    There is disclosed an expanded beam fiber to fiber connector, based on non-imaging optic principles for coupling light beams from one optical fiber to another. The system consists of two identical connector parts, referred to herein as a collimating part and a concentrating part, each having a preferred partially curved reflective boundary surface for minimizing power loss and surrounding either a hollow space or a space filled with a uniform transparent medium. In one embodiment the boundary is metallic while in a second embodiment the boundary is in the form of an interface allowing total internal reflection. In both the hollow and filled case a lens may be located at the expanded end of both the collimater part and the concentrator part forming the connector. The connector is preferably located in a housing in order to protect and preserve the mechanical stability of the coupler.

  7. Expanded beam non-imaging fiber optic connector

    DOEpatents

    Jannson, T.; Jannson, J.; Yeung, P.

    1990-02-06

    There is disclosed an expanded beam fiber to fiber connector, based on non-imaging optic principles for coupling light beams from one optical fiber to another. The system consists of two identical connector parts, referred to herein as a collimating part and a concentrating part, each having a preferred partially curved reflective boundary surface for minimizing power loss and surrounding either a hollow space or a space filled with a uniform transparent medium. In one embodiment the boundary is metallic while in a second embodiment the boundary is in the form of an interface allowing total internal reflection. In both the hollow and filled case a lens may be located at the expanded end of both the collimator part and the concentrator part forming the connector. The connector is preferably located in a housing in order to protect and preserve the mechanical stability of the coupler. 13 figs.

  8. KSC-08pd0062

    NASA Image and Video Library

    2008-01-16

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam insulation is being trimmed for placement around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  9. KSC-08pd0064

    NASA Image and Video Library

    2008-01-16

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam insulation is being trimmed for placement around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  10. KSC-08pd0063

    NASA Image and Video Library

    2008-01-16

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam insulation is being trimmed for placement around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  11. KSC-08pd0068

    NASA Image and Video Library

    2008-01-17

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, a technician trims foam placed around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  12. KSC-08pd0065

    NASA Image and Video Library

    2008-01-16

    KENNEDY SPACE CENTER, FLA. -- On Launch Pad 39A at NASA's Kennedy Space Center, foam insulation is being trimmed for placement around the engine cutoff, or ECO, sensor system connector and wiring on space shuttle Atlantis' external tank. The foam was removed to enable engineers to remove and replace a feed-through ECO sensor connector on the tank. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector were precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The launch date for the shuttle's STS-122 mission has now been targeted for Feb. 7. Photo credit: NASA/Kim Shiflett

  13. The Optical Harness: a light-weight EMI-immune replacement for legacy electrical wiring harnesses

    NASA Astrophysics Data System (ADS)

    Stark, Jason B.; Jackson, B. Scott; Trethewey, William

    2006-05-01

    Electrical wiring harnesses have been used to interconnect control and communication equipment in mobile platforms for over a century. Although they have served this function successfully, they have three problems that are inherent in their design: they are mechanically heavy and stiff, and they are prone to electrical faults, including arcing and Electro-Magnetic Interference (EMI), and they are difficult to maintain when faults occur. These properties are all aspects of the metallic conductors used to build the harnesses. The Optical Harness TM is a photonic replacement for the legacy electrical wiring harness. The Optical Harness TM uses light-weight optical fiber to replace signal wires in an electrical harness. The original electrical connections to the equipment remain, making the Optical Harness TM a direct replacement for the legacy wiring harness. In the backshell of each connector, the electrical signals are converted to optical, and transported on optical fiber, by a deterministic, redundant and fault-tolerant optical network. The Optical Harness TM: * Provides weight savings of 40-50% and unsurpassed flexibility, relative to legacy signal wiring harnesses; * Carries its signals on optical fiber that is free from arcing, EMI, RFI and susceptibility to HPM weapons; * Is self-monitoring during operation, providing non-intrusive predictive and diagnostic capabilities.

  14. Geohydrologic reconnaissance of drainage wells in Florida; an interim report

    USGS Publications Warehouse

    Kimrey, Joel O.; Fayard, Larry D.

    1982-01-01

    Drainage wells are used to inject surface waters directly into an aquifer, or shallow ground waters directly into a deeper aquifer, primarily by gravity. Such wells in Florida may be grouped into two broad types: (1) Surface-water injection wells, and (2) interaquifer connector wells. Surface-water injection wells are commonly used to supplement drainage for urban areas in karst terranes of central and north Florida. Data are available for 25 wells in the Ocala, Live Oak, and Orlando areas that allow comparison of the quality of water samples from these Floridan aquifer drainage wells with allowable contaminant levels. Comparison indicates that maximum contaminant levels for turbidity, color, and iron, manganese, and lead concentrations are equaled or exceeded in some drainage-well samples, and relatively high counts for coliform bacteria are present in most wells. Interaquifer connector wells are used in the phosphate mining areas of Polk and Hillsborough Counties, to drain mining operations and recharge the Floridan aquifer. Water-quality data available from 13 connector wells indicate that samples from most of these wells exceed standards values for iron concentration and turbidity. One well yielded a highly mineralized water, and samples from 6 of the other 12 wells exceed standards values for gross alpha concentrations. (USGS)

  15. Physiomodel - an integrative physiology in Modelica.

    PubMed

    Matejak, Marek; Kofranek, Jiri

    2015-08-01

    Physiomodel (http://www.physiomodel.org) is our reimplementation and extension of an integrative physiological model called HumMod 1.6 (http://www.hummod.org) using our Physiolibrary (http://www.physiolibrary.org). The computer language Modelica is well-suited to exactly formalize integrative physiology. Modelica is an equation-based, and object-oriented language for hybrid ordinary differential equations (http:// www.modelica.org). Almost every physiological term can be defined as a class in this language and can be instantiated as many times as it occurs in the body. Each class has a graphical icon for use in diagrams. These diagrams are self-describing; the Modelica code generated from them is the full representation of the underlying mathematical model. Special Modelica constructs of physical connectors from Physiolibrary allow us to create diagrams that are analogies of electrical circuits with Kirchhoff's laws. As electric currents and electric potentials are connected in electrical domain, so are molar flows and concentrations in the chemical domain; volumetric flows and pressures in the hydraulic domain; flows of heat energy and temperatures in the thermal domain; and changes and amounts of members in the population domain.

  16. Validation Assessment of a Glass-to-Metal Seal Finite-Element Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jamison, Ryan Dale; Buchheit, Thomas E.; Emery, John M

    Sealing glasses are ubiquitous in high pressure and temperature engineering applications, such as hermetic feed-through electrical connectors. A common connector technology are glass-to-metal seals where a metal shell compresses a sealing glass to create a hermetic seal. Though finite-element analysis has been used to understand and design glass-to-metal seals for many years, there has been little validation of these models. An indentation technique was employed to measure the residual stress on the surface of a simple glass-to-metal seal. Recently developed rate- dependent material models of both Schott 8061 and 304L VAR stainless steel have been applied to a finite-element modelmore » of the simple glass-to-metal seal. Model predictions of residual stress based on the evolution of material models are shown. These model predictions are compared to measured data. Validity of the finite- element predictions is discussed. It will be shown that the finite-element model of the glass-to-metal seal accurately predicts the mean residual stress in the glass near the glass-to-metal interface and is valid for this quantity of interest.« less

  17. Syntax and conversation in aphasia. A strategic restrictive use of Spanish and Catalan connector QUE by aphasic speakers.

    PubMed

    Hernández-Sacristán, Carlos; Rosell-Clari, Vicent

    2009-10-01

    Oral conversational data are deemed to be a relevant empirical source when it comes to formulating and supporting hypotheses about cognitive processes involved in aphasic linguistic production. With this assumption in mind, free conversational uses of the Spanish and Catalan connector QUE by fluent and non-fluent aphasic speakers are examined by contrasting them with normal speakers' (i.e. conversational partners') productions. Strictly ungrammatical uses in aphasic speakers are practically non-existent in free conversation. Nevertheless, this data permits one to characterize the aphasic production of the morpheme QUE as restrictive--to different degrees--with respect to normal production. Moreover, this restriction, selectively affecting the types of syntactic environments examined, can be considered strategic in nature: it is guided by some kind of knowledge about the administration of remnant linguistic resources.

  18. 2005 10th Annual Expeditionary Conference

    DTIC Science & Technology

    2005-10-27

    HIGH SPEED CONNECTORS/ SHIP INTERFACES PAUL BISHOP COALESCENT – BISHOP GROUP CO-DIRECTOR LOGISTICS Study Team 5 Bill...Force (CLF) 5. Connectors: High Speed Ship (HSS), High Speed Vessel (HSV), Assault Connectors (LCAC, EFV) 6. Sister Service and Coalition Force Ships ...of wartime cargo moves by ship Theater port infrastructure is critical to off-loading ships UNCLASSIFIED (U) Create a port Augment an established

  19. Umbilical mechanism

    NASA Technical Reports Server (NTRS)

    Barron, Daniel R. (Inventor); Jasulaitis, Vytas (Inventor); Morrill, Brion F. (Inventor)

    1995-01-01

    Apparatus is described for automatically mating a pair of connectors and protecting them prior to mating, which minimizes weight and uses relatively simple and reliable mechanisms. Lower and upper connectors (24, 26) are held in lower and upper parts (14, 16) of a housing, with the upper connector mounted on a carrier (32) that is motor driven to move down and mate the connectors. A pair of movable members (36, 38) serve as shields, as coarse alignment aids, and as force transmitters. The movable members are pivotally mounted at the bottom of the upper housing, and as the carrier moves down it pivots the members out of the way. The movable members have socket elements (116) that closely receive pin elements (120) on the lower housing part, to coarsely align the connectors and to react mating and unmating forces between the housings. The carrier has a pair of plate portions (60, 62) with slots (64), and the movable members have cam followers engaged with the slot walls, to move the members with precision. The carrier plate-like portions engage follower members (82) that pivot open lower shield parts (44, 46) covering the lower connector, which is mounted on four stacks of Belleville washers (142).

  20. Wood : mechanical fasteners

    Treesearch

    Douglas R. Rammer

    2001-01-01

    The strength and stability of any structure depends heavily on the fasteners that hold its parts together. One prime advantage of wood as a structural material is the ease with which wood structural parts can be joined together using a wide variety of fasteners: nails, staples, screws, lag screws, bolts, and various types of metal connectors. For the utmost rigidity,...

  1. Photovoltaic stand-alone modular systems, phase 2

    NASA Technical Reports Server (NTRS)

    Naff, G. J.; Marshall, N. A.

    1983-01-01

    The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

  2. Photovoltaic stand-alone modular systems, phase 2

    NASA Astrophysics Data System (ADS)

    Naff, G. J.; Marshall, N. A.

    1983-07-01

    The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

  3. High-power fiber optic cable with integrated active sensors for live process monitoring

    NASA Astrophysics Data System (ADS)

    Blomster, Ola; Blomqvist, Mats; Bergstrand, Hans; Pålsson, Magnus

    2012-03-01

    In industrial applications using high-brilliance lasers at power levels up to and exceeding 20 kW and similarly direct diode lasers of 10 kW, there is an increasing demand to continuously monitor component status even in passive components such as fiber-optic cables. With fiber-optic cables designed according to the European Automotive Industry fiber standard interface there is room for integrating active sensors inside the connectors. In this paper we present the integrated active sensors in the new Optoskand QD fiber-optic cable designed to handle extreme levels of power losses, and how these sensors can be employed in industrial manufacturing. The sensors include photo diodes for detection of scattered light inside the fiber connector, absolute temperature of the fiber connector, difference in temperature of incoming and outgoing cooling water, and humidity measurement inside the fiber connector. All these sensors are connected to the fiber interlock system, where interlock break enable functions can be activated when measured signals are higher than threshold levels. It is a very fast interlock break system as the control of the signals is integrated in the electronics inside the fiber connector. Also, since all signals can be logged it is possible to evaluate what happened inside the connector before the interlock break instance. The communication to the fiber-optic connectors is via a CAN interface. Thus it is straightforward to develop the existing laser host control to also control the CAN-messages from the QD sensors.

  4. Connector well experiment to recharge the Floridan Aquifer, East Orange County, Florida

    USGS Publications Warehouse

    Bush, P.W.

    1979-01-01

    An experimental connector well, screened in the shallow sand aquifer, finished with open hole in the Floridan aquifer, and cased through the confining layer between the two aquifers, was drilled in east Orange County, Florida, to obtain information on the nature and function of the shallow aquifer as related to connector well operation. The potentiometric surface of the shallow aquifer is about 45 feet higher than the potentiometric surface of the Floridan aquifer; hence water flows by gravity from the shallow aquifer to the Floridan aquifer through the well ' connecting ' the two aquifers. Continuous flow measurement over 10 months shows the well discharge varies seasonally and averages slightly more than 50 gallons per minute. Observation wells show that, except for seasonal variation water levels within the area of influence have reached steady state within measurable limits. Vertical anisotrophy in the shallow aquifer is apparently caused by the shape and (or) arrangement of the sand grains that comprise the shallow aquifer , rather than distinct confining layers of different lithology. Transmissivity of the shallow aquifer at the site is about 600 square feet per day. Extensive dewatering of wetlands in east Orange County by connector wells alone is probably not feasible. Nevertheless, large amounts of water could be channeled to the Floridan aquifer by connector wells. The results of the connector well experiment imply that water is being captured from evapotranspiration and runoff in the vicinity of the connector well. (Woodard-USGS)

  5. Armored umbilical apparatus for towing a marine seismic air gun sub array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, E.C.

    1985-06-25

    An armored umbilical and termination housing is disclosed for towing a sub-array of seismic air guns used in marine seismic surveying comprising a single air hose for supplying all the high pressure air to the individual air guns surrounded by all the electrical control cables needed to operate the air guns in the sub-array. Protective coatings are applied around the electrical control cables and stress members for carrying the load of towing the sub-array are incorporated within the umbilical. A termination housing is provided on the end of the umbilical for terminating the single air hose and all the electricalmore » control lines to common connectors so that individual electrical control lines and air hoses can run from the termination housing to each individual air gun in the sub-array. Air shut off valves are provided so that the high pressure air can be shut off to the individual air guns within the sub-array remotely from the survey vessel.« less

  6. Tuning conductivity in boron nanowire by edge geometry

    NASA Astrophysics Data System (ADS)

    Bhuyan, Prabal Dev; Gupta, Sanjeev K.; Sonvane, Yogesh; Gajjar, P. N.

    2018-04-01

    In present study, we have investigated electronic and temperature dependent transport properties of carbyne like linear chain and ribbon like zigzag structures of Boron (B) nanowire. The linear chain structure showed higher electric and thermal conductivity, as it is sp-hybridized, than its counterpart ribbon (R) structure. However the conductivity of ribbon structure increases with increases in width due to edge geometry effect. The ribbon (3R) structure showed high electric and thermal conductivity of 8.0×1019 1/Ω m s and 0.59×1015 W/ m K respectively. Interestingly we have observed that B linear chain showed higher thermal conductivity of 0.23×1015 W/ m K than its ribbon R and 2R structure above 600K. Because of high Seebeck co-efficient of boron chain and ribbon (R) structures at low temperature, they could find applications in thermoelectric sensors. Our results show that tuning conductivity property of boron nanowire could be of great interest in research for future electric connector in nanodevices.

  7. Design and Development of a Pressure Transducer for High Hydrostatic Pressure Measurements up to 200 MPa

    NASA Astrophysics Data System (ADS)

    Kumar, Anuj; Yadav, Sanjay; Agarwal, Ravinder

    2017-08-01

    A number of pressure transducers, based on strain gauge, capacitance/inductance type, frequency resonators, are commercially available and are being used for sensing and producing an electrical output proportional to applied pressure. These sensors have their own advantages and limitations due to operational ease, measurement uncertainty and the costs. Strain gauge type transducers are now well established devices for accurate and precise measurement of pressure within measurement uncertainty up to 0.1 % of full scale. In the present research work, an indigenous strain gauge pressure transducer has been designed, developed, tested and calibrated for pressure measurement up to 200 MPa. The measurement uncertainty estimated using the pressure transducer was found better than 0.1 % of full scale. This transducer was developed using four foil type strain gauges, bonded, two in axial direction while other two in radial direction, to the controlled stress zones of a tubular maraging steel active cylinder working also as diaphragm. The strain gages were then connected to a Wheatstone bridge arrangement to measure stress generated strains. The pressure was applied through matching connector designed in the same tubular transducer active element. The threaded unique design in a single piece through collar, ferule and tubing arrangement provides leak proof pressure connections with external devices without using additional seals. The calibration and performance checking of the pressure transducer was carried out using dead weight type national pressure standard using the internationally accepted calibration procedure.

  8. Methods and systems for rapid prototyping of high density circuits

    DOEpatents

    Palmer, Jeremy A [Albuquerque, NM; Davis, Donald W [Albuquerque, NM; Chavez, Bart D [Albuquerque, NM; Gallegos, Phillip L [Albuquerque, NM; Wicker, Ryan B [El Paso, TX; Medina, Francisco R [El Paso, TX

    2008-09-02

    A preferred embodiment provides, for example, a system and method of integrating fluid media dispensing technology such as direct-write (DW) technologies with rapid prototyping (RP) technologies such as stereolithography (SL) to provide increased micro-fabrication and micro-stereolithography. A preferred embodiment of the present invention also provides, for example, a system and method for Rapid Prototyping High Density Circuit (RPHDC) manufacturing of solderless connectors and pilot devices with terminal geometries that are compatible with DW mechanisms and reduce contact resistance where the electrical system is encapsulated within structural members and manual electrical connections are eliminated in favor of automated DW traces. A preferred embodiment further provides, for example, a method of rapid prototyping comprising: fabricating a part layer using stereolithography and depositing thermally curable media onto the part layer using a fluid dispensing apparatus.

  9. Photovoltaic building sheathing element with anti-slide features

    DOEpatents

    Keenihan, James R.; Langmaid, Joseph A.; Lopez, Leonardo C.

    2015-09-08

    The present invention is premised` upon an assembly that includes at least a photovoltaic building sheathing element capable of being affixed on a building structure, the photovoltaic building sheathing element. The element including a photovoltaic cell assembly, a body portion attached to one or more portions of the photovoltaic cell assembly; and at feast a first and a second connector assembly capable of directly or indirectly electrically connecting the photovoltaic cell assembly to one or more adjoining devices; wherein the body portion includes one or more geometric features adapted to engage a vertically adjoining device before installation.

  10. Photonically wired spacecraft panels: an economic analysis and demonstrator for telecommunication satellites

    NASA Astrophysics Data System (ADS)

    Putzer, Philipp; Hurni, Andreas; Ziegler, Bent; Panopoulou, Aikaterini; Lemke, Norbert; Costa, Ivo; Pereira, Celeste

    2017-09-01

    In this paper we present the design of smart satellite panels with integrated optical fibers for sensing and data communication. The project starts with a detailed analysis of the system needs and ends with a demonstrator breadboard showing the full performance during and after environmental tests such as vibrations and temperature. Future science missions will need higher bandwidth in the Gbit/s range for intra-satellite communications, so the step from electrical transmission media towards fiber-optical media is the logical next step to cope with future requirements. In addition, the fibers can be used to monitor temperatures directly underneath satellite payloads which will reduce the integration effort in a later phase. For temperature monitoring so called fiber Bragg gratings (FBGs) are written in special radiation tolerant fibers, which reflection wavelength allows a direct link to temperature at the grating position. A read-out system for FBGs to use within satellite applications is currently under development at OHB. For this study, first the environmental requirements for the panels are derived and in a second stage the functional requirements are defined. To define the functional requirements a telecommunication satellite platform, in the case here the Small-GEO series from OHB, has been taken as baseline. Based on the configuration of temperature sensors, communication lines and electrical signaling a possible replacement by fiber-optical technology was defined and traded w.r.t. its economic benefit. It has been pointed out that the replacement of temperature sensors will reduce harness mass, but the great benefit is seen here in the reduction of assembly effort. Once the satellite panel is manufactured, the temperature sensors are already implemented at certain positions. Another point for mass savings which has pointed out is the replacement of the high-voltage or high- current high power commands (HPC) by fiber optics. Replacing some of the several hundred of required HPC lines with very light-weight fibers would reduce the HPC harness by some tens of kilograms. A detailed table illustrating the mass savings and also the integration time savings will be presented in the paper. To keep the track on an economic solution also a detailed market research was carried out to find suitable components for fiber-optical connectors, fibers and protections buffers. Specially for the connectors a solution based on military qualified connectors pointed out to be the most interesting solution in terms of price and functionality, especially when using multi-pole connectors. The project closes with the construction of a breadboard demonstrator consisting of three different panels, one large panel (ca. 1 m²) and two smaller panels (ca. 0.3 m²). The large panel and one of the small panels are made out of aluminum facesheets whereas the other small panels is made out of CFRP.

  11. Fibre optic connectors with high-return-loss performance

    NASA Astrophysics Data System (ADS)

    Knott, Michael P.; Johnson, R.; Cooke, K.; Longhurst, P. C.

    1990-09-01

    This paper describes the development of a single mode fibre optic connector with high return loss performance without the use of index matching. Partial reflection of incident light at a fibre optic connector interface is a recognised problem where the result can be increased noise and waveform distortion. This is particularly important for video transmission in subscriber networks which requires a high signal to noise ratio. A number of methods can be used to improve the return loss. The method described here uses a process which angles the connector endfaces. Measurements show typical return losses of -55dB can be achieved for an end angle of 6 degrees. Insertion loss results are also presented.

  12. Electronic inverter assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Brij N.; Schmit, Christopher J.

    A first driver portion comprises a set of first components mounted on or associated with a first circuit board. A second circuit board is spaced apart from the first circuit board. A second driver portion comprises a set of second components mounted on or associated with the second circuit board, where the first driver portion and the second driver portion collectively are adapted to provide input signals to the control terminal of each semiconductor switch of an inverter. A first edge connector is mounted on the first circuit board. A second edge connector is mounted on the second circuit board.more » An interface board has mating edges that mate with the first edge connector and the second edge connector.« less

  13. Six-degree-of-freedom multi-axes positioning apparatus

    DOEpatents

    Bieg, L.F.X.

    1999-05-11

    A six-degree-of-freedom multi-axes positioning apparatus is comprised of a geometry of six independent angle connectors. Each angle connector connects two fixed length rods to a pivot on one of two opposing platforms. The combination of an angle connector, at least two pivots and at least two rods having free ends connected to the pivots comprises a leg assembly. The spatial location of the upper platform is changed in relation to the lower platform by angular changes within each angle connector. This angular change results in degrees of motion within the apparatus defined as X, Y, Z, Tip, Tilt, and Rotation, or a combination of the above. This invention is known as a ROTOPOD. 9 figs.

  14. Six-degree-of-freedom multi-axes positioning apparatus

    DOEpatents

    Bieg, Lothar F. X.

    1999-01-01

    A six-degree-of-freedom multi-axes positioning apparatus is comprised of a geometry of six independent angle connectors. Each angle connector connects two fixed length rods to a pivot on one of two opposing platforms. The combination of an angle connector, at least two pivots and at least two rods having free ends connected to the pivots comprises a leg assembly. The spatial location of the upper platform is changed in relation to the lower platform by angular changes within each angle connector. This angular change results in degrees of motion within the apparatus defined as X, Y, Z, Tip, Tilt, and Rotation, or a combination of the above. This invention is known as a ROTOPOD.

  15. KSC-07pd3667

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, technicians place the wrapped connector in a shipping container for transport to NASA's Marshall Space Flight Center in Huntsville, Ala., for further cryogenic testing. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  16. KSC-07pd3668

    NASA Image and Video Library

    2007-12-30

    KENNEDY SPACE CENTER, FLA. -- At Launch Pad 39A, a team of external tank specialists from Lockheed Martin and the United Space Alliance undertakes the task of removing the hydrogen feed-through connector in support of space shuttle Atlantis' STS-122 mission. Here, a technician carries the shipping container in which the wrapped connector is secured for transport to NASA's Marshall Space Flight Center in Huntsville, Ala., for further cryogenic testing. Some of the tank's engine cutoff sensors, or ECO sensors, failed during propellant tanking for launch attempts on Dec. 6 and Dec. 9. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The feed-through connector passes the wires from the inside of the tank to the outside. After the data from additional testing on the connector is analyzed, shuttle program managers will decide on a forward plan. Launch of STS-122 is targeted for January 2008. Photo credit: NASA/George Shelton

  17. [Stress distribution in abutment teeth and related tissues under different design of connector: three-dimensional finite element analysis].

    PubMed

    Bai, Li-Ming; Li, Guo-Qiang; Zhang, Qiang; Dong, Xian

    2016-08-01

    To compare the stress distribution in abutment teeth and related tissues under the same material and different loading between improved major connector design and traditional major connector design. One 55-year-old male patient with unilateral maxillary first molar and second molar missing was chosen. The stress distribution in abutment teeth and related tissues were evaluated with spiral CT scanning, Mimics, Geomagic Studio software, a study model was built and finite element analysis was performed using ANSYS software. With the improved major connector design, the stress of abutment decreased significantly, the stress of periodontal decreased, the stress of edentulous mucosa increased significantly and became more balanced, the trend of stimulated absorption of alveolar bone decreased. For patients with distal free defect of dentition, the design of improved major connector has the effect of stress interruption, can protect the abutment better, detract the stress of the denture and has an good protective effect on the edentulous mucosa and alveolar bone.

  18. KSC-08pd0037

    NASA Image and Video Library

    2008-01-13

    KENNEDY SPACE CENTER, FLA. -- Lloyd Johns, with Lockheed Martin, prepares the area where the replacement feed-through connector in the engine cutoff, or ECO, sensor system on space shuttle Atlantis' external tank will be installed. Seen next to Johns' arm is the internal connector. The area is wrapped in material for weather protection. Berger wears safety equipment as helium gas is employed to keep the equipment under wrap dry. The feed-through connector passes the wires from the inside of the tank to the outside. Results of a tanking test on Dec. 18 pointed to an open circuit in the feed-through connector wiring, which is located at the base of the tank. The pins in the replacement connector have been precisely soldered to create a connection that allows sensors inside the tank to send signals to the computers onboard Atlantis. The work is being done on Launch Pad 39A. Space shuttle Atlantis is now targeted for launch on Feb. 7. Photo credit: NASA/George Shelton

  19. An Automated Safe-to-Mate (ASTM) Tester

    NASA Technical Reports Server (NTRS)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  20. Investigation of gold embrittlement in connector solder joints

    NASA Technical Reports Server (NTRS)

    Lane, F. L.

    1972-01-01

    An investigation was performed to determine to what extent typical flight connector solder joints may be embrittled by the presence of gold. In addition to mapping of gold content in connector solder joints by an electron microprobe analyzer, metallographic examinations and mechanical tests (thermal shock, vibration, impact and tensile strength) were also conducted. A description of the specimens and tests, a discussion of the data, and some conclusions are presented.